1 FWT-200 OPTI-CHROMIC READER SYSTEM User s Manual Covers Installation and Windows software for ISA and PCI cards September, 2002 Far West Technology, Inc. 330 South Kellogg Ave. Suite D Goleta, CA USA

2 INTRODUCTION The FWT-200 Opti-Chromic Reader is a computer controlled densitometer designed to read FWT-70 Opti- Chromic Detectors. The complete reader system consists of a computer (IBM PC\XT\AT compatible), the reader head, an ADC card for the computer (ISA and PCI versions available), a cable to connect the head to the card, and software. HARDWARE INSTALLATION Dedicated Computer We recommend that you use a dedicated computer for the Model 200. We have found that users who network, run multiple programs, or use inexpensive computers often have poor results with the Model 200. If you do have problems, stop multitasking, shut down all concurrent programs, remove the network connection, remove excess hardware and/or try a better quality computer. ADC Board (ISA Version) Before installing the ADC board in the computer you need to note the base address of the board. If you have other expansion cards in the computer you should also check that the base address does not conflict with the address of the other cards. If necessary, the base address may be altered by changing the DIP switch on the ADC card. To determine the base address of the card examine the DIP switch settings and the numbers printed on the printed circuit board (not the numbers on the DIP switch housing). The card is originally set up with an address of 0x300, which has switches 3 and 4 off and switches 5-9 on. The base address of the ADC card may be changed to provide a range of selections to the user. Table 1 gives the decimal and hexadecimal values and the position of each switch. Note the base address of the card so that this may be specified in the configuration file (DOS software version 1.x) or in the setup dialog box (version 2.x). The windows version allows you to specify the base address by showing how the DIP switches are set. Consult your computer manual for details on installing an expansion card in your computer. Most installations are as follows: First make sure that the computer is turned off and unplugged. Next open the case to allow access to the expansion slots. Choose an appropriate empty slot for the card. Remove the retaining bracket, being careful not to drop the screw in the computer. Firmly insert the card in the slot and screw the bracket to the chassis. Replace the case. ADC Board (PCI Version) See the PCI-DAS08 User s Manual for installation instructions for the PCI version of the ADC card. IMPORTANT: The PCI Board and supporting software should be installed before the FWT200 software is installed. Then the InstaCal program should be run and the PCI-DAS08 board added to the list of recognized boards. Connecting the Head to the Card Before connecting the head to the card you should make sure that the computer is turned off. Connect one end of the supplied cable to the card and the other end to the reader head (the two ends are interchangeable for the ISA card; the cable for connecting to a PCI card has different connectors on the two ends and is FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 1

3 different than the PCI cable for the FWT-100). Securely fasten them by tightening the screws on the connectors. Table 1 - FWT-300 Computer ADC Card Base Address Selection NOTE: Addresses 000 to 0FF hex used by internal I/O Address DIP Switch Settings Dec Hex on on on on on off on off on on on on off on on off on on on off on off off on on on off on on on off on on off on off on off on on off on on off off on on off on off off off on on off on on on on off on off on off on on off on off on on off on off on off on off off on off on off on on on off off on off on off on off off on off on on off off off on off on off off off off on off on on on on on off off on off on on on off off on on off on on off off on off off on on off off on 416 1A0 on on off on off off on 424 1A8 off on off on off off on 432 1B0 on off off on off off on 440 1B8 off off off on off off on 448 1C0 on on on off off off on 456 1C8 off on on off off off on 464 1D0 on off on off off off on 472 1D8 off off on off off off on 480 1E0 on on off off off off on 488 1E8 off on off off off off on 496 1F0 on off off off off off on 504 1F8 off off off off off off on Do not use - Reserved for system Do not use - Reserved for system on off on on on on off off off on on on on off on on off on on on off off on off on on on off on off off on on on off off off off on on on off on on on off on on off off on on off on on off on off on off on on off off off on off on on off on on off off on on off off on off off on on off on off off off on on off FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 2

4 Address DIP Switch Settings Dec Hex Do not use - Reserved for system on on on on off on off off on on on off on off on off on on off on off off off on on off on off 672 2A0 on on off on off on off 680 2A8 off on off on off on off 688 2B0 on off off on off on off 696 2B8 off off off on off on off 704 2C0 on on on off off on off 712 2C8 off on on off off on off 720 2D0 on off on off off on off 728 2D8 off off on off off on off 736 2E0 on on off off off on off 744 2E8 off on off off off on off 752 2F0 on off off off off on off 760 2F8 Do not use - Reserved for system on on on on on off off DEFAULT SETTING off on on on on off off on off on on on off off off off on on on off off Do not use - Reserved for system Do not use - Reserved for system on off off on on off off off off off on on off off on on on off on off off off on on off on off off on off on off on off off off off on off on off off on on off off on off off off on off off on off off on off off off on off off Do not use - Reserved for system on on on on off off off off on on on off off off on off on on off off off off off on on off off off 928 3A0 on on off on off off off 936 3A8 off on off on off off off 944 3B0 Do not use - Reserved for system 952 3B8 Do not use - Reserved for system 960 3C0 on on on off off off off 968 3C8 off on on off off off off 976 3D0 on off on off off off off 984 3D8 off off on off off off off 992 3E0 on on off off off off off E8 Do not use - Reserved for system F0 Do not use - Reserved for system F8 Do not use - Reserved for system FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 3

5 Lamp Replacement The FWT-200 comes with a lamp installed and one spare lamp taped to the inside of the lamp access cover. When the lamp burns out or becomes too dim you should replace it. To replace the lamp first remove the access cover by unscrewing the black thumb screw on the back of the reader head. Remove the access cover and, from the bottom of the reader, unscrew the black thumb screw which holds the lamp in place. Disconnect the lamp from the circuit board by pulling the connector off the board. Remove the lamp and discard it. Insert the new lamp into the holder as far as it will go and tighten the thumb screw just enough to prevent the lamp from moving. Do not over tighten the screw or you may damage the lamp's housing. Attach the lamp's connector to the circuit board. Replace the access cover. Dosimeter Well The FWT-200 has a dosimeter well that accepts FWT-70 Opti-Chromic dosimeters and FWT-160 Neutral Density filters. The lid to the well should be closed whenever you take a reading (zero, dosimeter or filter). Dosimeters are placed in the light path, which is parallel to the front of the reader. A neutral density filter is inserted in the slot on the right side of the well. Drape the filter s identification tab to the right so it will lay between the top of the reader housing and the well lid rather than being draped into the well. Software Version 1.x (for DOS) This software is located in the DOS folder on the CD-ROM. Information on the nstallation and use of the FWT- 200 software, v.1.x for DOS may be found in the file MANUAL1.DOC or Manual.pdf in that folder. Software version 2.x (for Windows) Version 2.x of the FWT-200 software is an applet that communicates with other programs (such as a spreadsheet, database, or word processor) through dynamic data exchange (DDE) links. The applet displays the absorbance, wavelength and any error message, and makes these available to other programs. Installation Insert the CD-ROM into your computer. Use Windows Explorer (or similar) to navigate to the appropriate ISA or PCI directory on the CD-ROM drive. Double-click the setup.exe file to run the setup. Follow the instructions in the setup program to install the software. Running the Software From Window s Start Program menu select FWT200 or FWT200PCI to run the appropriate software for your card. The file will be in the Far West Technology folder if you accepted the default folder during installation. The first time the software is run on a computer it will display the Port Address Setup (or PCI Card Setup) dialog box. In the PCI software select the PCI-DAS08 card from the pull-down list and click the accept button. In the ISA software specify the port address either by entering the address (in hexadecimal) into the address box or by clicking the DIP switch display to indicate how the switches are set on the card. You may then test the address before accepting it. The main display for the software is a box with the menus, wavelength being analyzed and absorbance reading. The only option on the File menu allows you to Exit the program. The only active option on the Help menu will give you information About the software, including the version number. FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 4

6 The Setup menu has five options. Shut Motor Off or Turn Motor On In order to increase the life of the motor you may shut the motor off if you do not plan to use the reader for an extended period of time. Once you shut the motor off the menu option changes so you may turn the motor on and continue reading. NOTE: the motor should automatically stop anytime you exit the program. Neutral Density Filter Check allows you to verify reader performance by analyzing neutral density filters (NDF). When you select this option a dialog box will appear. With the dosimeter well empty and the lid closed, you should click on the zero button. Zeroing will enable the three filter buttons. You may then place any filter into the reader and click the appropriate button to take readings of that filter. Do this for one or more of the filters. The absorbances will display on the screen and are available through a DDE link (see DDE Links section below). The software uses a calibration factor to adjust the ADC readings to absorbance readings. This check will give you the information you need to adjust this calibration factor, if desired (you may also treat the difference between the observed NDF values and the certified values as a bias of the reader). The default calibration factor is 1.9. The calibration factor may be changed using the fwtgain.exe program in the support directory of the CD-ROM. Start the program, enter the reader s serial number. The program will display the current (or default) value for the reader. You may change the value or exit the program without changing the value. Decreasing the gain will decrease the absorbance readings; thus if your NDF readings average about 2% high you would adjust the gain down 2%. Zero allows you to zero the absorbance reading. The reading may change over time a slow drift in zero is normal. Wavelength allows you to select for which wavelength(s) to display absorbance data. Port brings up the Port Address Setup dialog box, discussed above. DDE Links Dynamic Data Exchange (DDE) links allow data to be transferred from one program to another. The FWT200 program allows other programs to access the absorbance reading for a wavelength. The communication is established with a link source of fwt200 (for the ISA version of the program) or fwt200pci (for the PCI version), a topic of data, and an items of a1, a2 and a3 for absorbance at the primary (typically 600 nm), secondary (typically 656 nm) and reference (typically 750 nm) wavelengths, respectively; lbla1, lbla2 and lbla3 are the primary, secondary and reference wavelengths, respectively (for example, 600 nm, 656 nm and 750 nm ); na1, na2, na3, for the absorbances of neutral density filter A (the light filter) at the primary, secondary and reference wavelengths, respectively; nb1, nb2, nb3, for the absorbances of neutral density filter B (the medium filter) at the primary, secondary and reference wavelengths, respectively; nc1, nc2, nc3, for the absorbances of neutral density filter C (the dark filter) at the primary, secondary and reference wavelengths, respectively; wl, for the wavelength; wl is 1 if only the primary wavelength is displayed, it is 2 if only the secondary wavelength is displayed, and it is 3 if both wavelengths are displayed. FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 5

7 Consult the software manual for your spreadsheet, database or word processor to determine its capabilities for DDE communication and the appropriate syntax. In Microsoft Excel the syntax is: =fwt200 data!a1 to have the cell s contents reflect the absorbance reading at the primary wavelength using an ISA card. The pipe character,, separates the program name and topic; an exclamation point,!, separates the topic and item. The fwt200.xls spreadsheet in the support directory on the distribution CD-ROM illustrates how the data may be accessed, how a dose may be determined from default initial absorbance and a lookup table, and how to copy the information as data (rather than links) into another area of the spreadsheet. Troubleshooting If you are having problems with the FWT200 reader or software please check the following: 1. Reader is securely fastened to the ADC card using the cable supplied by Far West Technology. 2. Computer is connected to an appropriate stable power supply and is turned on. We encourage the use of a quality computer, surge protection and any line filter needed to provide the computer with a stable voltage input. 3. The lamp is on. If there is no light first check items 1 and 2 above, then try replacing the lamp, per the directions in the Lamp Replacement section above. 4. The reader s optical path is clear. Be sure there are no dosimeters in the reader. If the above actions do not solve your problem you may check our website ( for additional information on troubleshooting or contact us at: Far West Technology, Inc. 330 S Kellogg Ave, Suite D Goleta, CA USA Tel.: +1 (805) Fax: +1 (805) info@fwt.com When contacting us, please indicate the following: 1. The version of the FWT200 software you are using (see the Help About dialog box) and whether you are using a PCI or ISA card. 2. The version of Windows you are using. 3. The serial number of your reader. 4. Contact information, including contact name, company, location (include country if outside the USA) fax number and address. 5. A complete description of the problem you are experiencing. FAR WEST TECHNOLOGY FWT 200 Opti-Chromic Reader PAGE 6

EPAS Desktop Pro Software User Manual

EPAS Desktop Pro Software User Manual Software User Manual Issue 1.10 Contents 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started 6 2.1

More information

Hardware installation guide

Hardware installation guide Getting Started Hardware installation guide Index Introduction Introduction...3 General Note... 3 Getting Help... 3 Deinstallation... 3 GPIB-PCMCIA (11.001.00)...4 Microsoft Windows 95/98... 4 Microsoft

More information

Cannondale Diagnostic Tool Manual

Cannondale Diagnostic Tool Manual Cannondale Diagnostic Tool Manual For vehicles (ATV & Motorcycles) equipped with the MC1000 Engine Management System Software CD P/N 971-5001983 Data Cable P/N 971-5001984 POTENTIAL HAZARD Running the

More information

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software CurveMaker DFS v2.0 Dyna FS Ignition Programming Software Contents Dynatek 164 S. Valencia St. Glendora, CA 91741 phone (626)963-1669 fax (626)963-7399 page 1) Installation 1 2) Overview 1 3) Introduction

More information

Issue 2.0 December EPAS Midi User Manual EPAS35

Issue 2.0 December EPAS Midi User Manual EPAS35 Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started

More information

PSC1-003 Programmable Signal Calibrator

PSC1-003 Programmable Signal Calibrator PSC1-003 Programmable Signal Calibrator Description: The PSC1-003 Programmable Signal Calibrator provides precise calibration of fuel by adjusting fuel control signals. It can be used with naturally aspirated

More information

RDS. For Windows TORSION SPRING CALCULATOR For ROLLING DOORS Version 4 REFERENCE MANUAL

RDS. For Windows TORSION SPRING CALCULATOR For ROLLING DOORS Version 4 REFERENCE MANUAL RDS For Windows TORSION SPRING CALCULATOR For ROLLING DOORS Version 4 REFERENCE MANUAL TABLE OF CONTENTS TABLE OF CONTENTS INTRODUCTION CREATING THE WORKING COPY INSTALLATION GETTING STARTED i iii iv v

More information

Version 1.0 Copyright DC-RPM-iBox User Manual

Version 1.0 Copyright DC-RPM-iBox User Manual Version 1.0 Copyright 2012 DC-RPM-iBox User Manual D Y N O C O M S E R I E S C H A S S I S D Y N A M O M E T E R S DC-RPM-iBox User Manual Copyright This manual is copyrighted by Dynocom Industries, Inc.,

More information

Service & Maintenance

Service & Maintenance Service & Maintenance Amplifier Monitor LEDs & Tubes (Wall-Rock-PV) Translucent Panel (Wall-Rock-PV) Glass Panel (Rock-Star) Fans & Filter G2-1 External Peavey Amplifier) Amplifier Removal 1. Disconnect

More information

PRESSURE SENSOR INSTRUCTIONS

PRESSURE SENSOR INSTRUCTIONS PRESSURE SENSOR INSTRUCTIONS Overview: Pressure sensors are an analog style sensor that produces a voltage from 0V to 5V depending on the amount of pressure applied and the range of the sensor. If you

More information

Network Installation. July 2008 CONTENTS

Network Installation. July 2008 CONTENTS Network Installation CONTENTS General Software Hard Lock System Requirements Installation on Server Installation on Each Work Station Directory Structure July 2008 Require PowerCad-5 Ver 5.0.72.0 PowerCad-5

More information

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

CurveMaker HD v1.0 2Ki Programmable Ignition programming software Contents CurveMaker HD v1.0 2Ki Programmable Ignition programming software Dynatek 164 S. Valencia St. Glendora, CA 91741 phone (626)963-1669 fax (626)963-7399 page 1) Installation 1 2) Overview 1 3) Programming

More information

Atomic Absorption Spectroscopy

Atomic Absorption Spectroscopy Atomic Absorption Spectroscopy Atomic absorption spectroscopy (AAS) is a widely used technique for determining a large number of metals. In the most common implementation of AAS, a liquid sample containing

More information

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

CENTROIDTM. AC Brushless Drive. Product Spec Sheet 4 Axis, up to 2 KW motors Brake Output for each axis Overtemp and Overcurrent Protection All-software Configuration Self-cooled Fiber Optic Control CENTROIDTM AC Brushless Drive Product Spec Sheet AC Brushless

More information

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation INDEX 1 Introduction 1.1 Features of the Software 2- Software installation 3 Open the program 3.1 Language 3.2 Connection 4 Folder General - F2. 4.1 The sub-folder Error visualization 5 Folder Configuration

More information

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7 SET UP MANUAL INDEX 1 Introduction 1.1 Features of the Software 2- Software installation 3 Open the program 3.1 Language 3.2 Connection 4 General - F2 4.1 The sub-folder Error visualization 5 Configuration

More information

Introduction. Figure 1: Labeled picture of the Instron 3367 load frame.

Introduction. Figure 1: Labeled picture of the Instron 3367 load frame. Operation of the Instron Tensile Test Machine With an Existing Method in Bluehill 3 Software Introduction by Andrew E. Frerichs, 3/25/11 Michelle Grawe; 10/6/14 Introduction The Instron device is a displacement

More information

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems. IntelliSens App

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems. IntelliSens App IntelliSens App For Android & ios devices Revision 2.0 17.10.2016 Overview Function flow... 3 HC1000... 4 First Steps... 5 How to Read a Sensor... 7 How to Program a Sensor... 10 Program a Single Universal

More information

MetaXpress PowerCore System Installation and User Guide

MetaXpress PowerCore System Installation and User Guide MetaXpress PowerCore System Installation and User Guide Version 1 Part Number: 0112-0183 A December 2008 This document is provided to customers who have purchased MDS Analytical Technologies (US) Inc.

More information

R and R Meritor WABCO Enhanced Easy-Stop Trailer ABS Replacement Kits for Easy-Stop ECU/Modulator Valve Assembly Part Number

R and R Meritor WABCO Enhanced Easy-Stop Trailer ABS Replacement Kits for Easy-Stop ECU/Modulator Valve Assembly Part Number Issued 06-03 Installation Guide Hazard Alert Messages Read and observe all Warning and Caution hazard alert messages in this publication. They provide information that can help prevent serious personal

More information

Before you begin using your Allegro CX. Complete all of the steps outlined in each section of this guide.

Before you begin using your Allegro CX. Complete all of the steps outlined in each section of this guide. Before you begin using your Allegro CX Complete all of the steps outlined in each section of this guide. QUICK START GUIDE Installing the battery pack into the Allegro Before turning on the Allegro, the

More information

SPEEDKEY KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 9. GEM e2, e4, e6, el XD

SPEEDKEY KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 9. GEM e2, e4, e6, el XD SPEEDKEY KIT P/N 2883054 APPLICATION GEM e2, e4, e6, el XD BEFORE YOU BEGIN Read these instructions and check to be sure all parts and tools are accounted for. Please retain these installation instructions

More information

GPS Steering System Installation Manual

GPS Steering System Installation Manual GPS Steering System Installation Manual Supported Vehicles Challenger Massey Ferguson AGCO MT-645C, MT-645D MF-8650 DT-205B MT-655C, MT-655D MF-8660 DT-225B MT-665C, MT-665D MF-8670 DT-250B MT-675C, MT-675D

More information

Safety Considerations

Safety Considerations Safety Considerations The following safety rules MUST BE FOLLOWED to ensure safety in the laboratory. General Considerations No smoking, eating or drinking in the laboratory. Hydraulic oil in its vapor

More information

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A INSTALLATION MANUAL Fendt VarioGuide Ready COM 3 Supported Models 922 924 927 930 933 936 PN 602-0264-02 REV A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual carefully before installing

More information

Operating Instructions Operating Instructions. HEKA testing lane UNIVERS "TX" 4cm above floor

Operating Instructions Operating Instructions. HEKA testing lane UNIVERS TX 4cm above floor 1 Operating Instructions Operating Instructions Brakes, suspension and toe Manufacturer: HEKA AUTO TEST GMBH Ensisheimer Str. 4 79110 Freiburg / Germany Tel.: +49-761-81080 E-Mail: info@heka-online. For

More information

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number 28640996 and After Record Platter System Identification Numbers Here: Model # Serial # Table of Contents Program

More information

AOYUE INT. Advanced Repairing System NT 701A++ INSTRUCTION MANUAL

AOYUE INT. Advanced Repairing System NT 701A++ INSTRUCTION MANUAL AOYUE NT 701A++ INT Advanced Repairing System INSTRUCTION MANUAL Thank you for purchasing Aoyue Int701A++ Repairing System. It is important to read the manual before using the equipment. Please keep manual

More information

Model 2500 Horsepower Computer System User Manual

Model 2500 Horsepower Computer System User Manual Model 2500 Horsepower Computer System User Manual Manufacturered by: Ries Labs, Inc. 2275 Raven Road Farina, IL 62838 Phone: (618) 238-1400 email: admin@rieslabs.com Table of Contents Description ----------------------------------------------------------------

More information

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide. 1993-2001 Dynojet Research, Inc. All Rights Reserved.. This manual is copyrighted by Dynojet Research, Inc., hereafter referred to as Dynojet, and all rights are reserved. This manual, as well as the software

More information

Error Code List for ecash & Nanocash

Error Code List for ecash & Nanocash Error Code List for ecash & Nanocash 20001 Unable to load a cassette. Removed and replace cassette Check the microswitch located on the inside left wall of the dispenser. 20002 Low cash. Replenish the

More information

Introduction Safety precautions for connections... 3 Series 3700 documentation... 4 Model 3732 overview... 5 Accessories...

Introduction Safety precautions for connections... 3 Series 3700 documentation... 4 Model 3732 overview... 5 Accessories... Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 3732 Quad 4x28 Reed Relay Card Connection Information Table of contents Introduction... 3

More information

IBM CMM Quick Reference Guide

IBM CMM Quick Reference Guide IBM CMM Quick Reference Guide Contents Introduction Prerequisites Requirements Components Used CMM Overview CMM Layout Useful CMM Screens Login Screen System Information Screen Event Log Screen Chassis

More information

HP DesignJet 430 HP DesignJet 450C HP DesignJet 455CA Printers. Service Manual

HP DesignJet 430 HP DesignJet 450C HP DesignJet 455CA Printers. Service Manual HP DesignJet 430 HP DesignJet 450C HP DesignJet 455CA Printers Service Manual For HP Internal Use Only Copyright Hewlett- Packard Company 1997 This document contains proprietary information that is protected

More information

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine Introduction An ISO 9001:2008 Registered Company ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown 2014-2016 Isuzu NPR 6.0L Gasoline Engine Contact InterMotive for additional vehicle applications

More information

USER S GUIDE LandAirSea 7100 Real Time GPS Tracking System

USER S GUIDE LandAirSea 7100 Real Time GPS Tracking System USER S GUIDE LandAirSea 7100 Real Time GPS Tracking System 1.1 Introduction The LandAirSea 7100 is a web-based real time tracking system that uses GPS technology to accurately determine the exact location

More information

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28 REV F2.0 User's Manual Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28 Table of Contents INTRODUCTION...4 Starting TOOLBOX Software... 5 MAIN MENU...6 System Setup... 6 Language... 7 Select

More information

Solution / Instructions

Solution / Instructions Error 20001 Tranax & Hyosung Error Code List Error Description Unable to load a cassette 20002 Low Cash 20003 20004 20010 20012 20013 20014 2xx15 Axxx1 Axxx2 Axxx3 Axxx4 Axxx5 Axxx8 Reject Bin is Full

More information

XC Instrumentation System Owner s Manual Revision /05/06

XC Instrumentation System Owner s Manual Revision /05/06 XC Instrumentation System Owner s Manual Revision 3.0 07/05/06 XC INSTRUMENTATION SYSTEM OWNER S MANUAL 1 Revision History Date New Revision Level Revision Description 11/08/05 1.0 Initial release 05/24/06

More information

TRW Commercial Steering Torque Overlay Diagnostic Tool

TRW Commercial Steering Torque Overlay Diagnostic Tool TRW Commercial Steering Torque Overlay Diagnostic Tool Ver. 1.0.0.6 September 16, 2014 Page 1 of 13 The TRW Torque Overlay Diagnostic Tool is intended to assist a service technician answer the following

More information

4.1 Flow Rate Verification and Adjustment

4.1 Flow Rate Verification and Adjustment 4.1 Flow Rate Verification and Adjustment Once the pressure verification is complete (see Chapter 3), the gas flow rate should be verified. Accurate gas flow through the nozzle is critical for achieving

More information

Table of Contents 1. INTRODUCTION GENERAL INFORMATION-ABOUT OBDII/EOBD PRODUCT DESCRIPTIONS OPERATIONS...11

Table of Contents 1. INTRODUCTION GENERAL INFORMATION-ABOUT OBDII/EOBD PRODUCT DESCRIPTIONS OPERATIONS...11 Table of Contents 1. INTRODUCTION...1 2. GENERAL INFORMATION-ABOUT OBDII/EOBD...1 2.1 ON-BOARD DIAGNOSTICS (OBD) II...1 2.2 DIAGNOSTIC TROUBLE CODES (DTCS)...2 2.3 LOCATION OF THE DATA LINK CONNECTOR (DLC)...3

More information

CenterLine Filter Wheel

CenterLine Filter Wheel Engineering Excellence Because Your Image Depends On It User s Guide CenterLine Filter Wheel Finger Lakes Instrumentation, LLC September 2014 WELCOME Thank you for purchasing an FLI CenterLine Filter Wheel.

More information

Installation Instructions for: EMS P/N Ford Mustang 5.0L

Installation Instructions for: EMS P/N Ford Mustang 5.0L Installation Instructions for: EMS P/N 30-1400 1986-93 Ford Mustang 5.0L! WARNING: This installation is not for the tuning novice nor the PC illiterate! Use this system with EXTREME caution! The AEM EMS

More information

Motorized Electric Latch Retraction

Motorized Electric Latch Retraction ; SECTION I: OVERVIEW 1. Description The Corbin Russwin MELR Electric Latch Retraction (ELR), refer to Figure 1, works with ED4000 & ED5000 Series exit devices to provide remote-controlled latch retraction

More information

AR2000 Rheometer: Instructions

AR2000 Rheometer: Instructions AR2000 Rheometer: Instructions Instrument Setup Note: The order in which the things are powered on is very important! 1. Check to make sure the Smart Swap cable is connected to the machine. 2. Make sure

More information

Advanced User Manual

Advanced User Manual Advanced User Manual Banks SpeedBrake For use with Palm Tungsten E2 2004-2005 Chevy/GMC 6.6L (LLY) Turbo-Diesel Pickup THIS MANUAL IS FOR USE WITH KITS 55419 & 55421 Gale Banks Engineering 546 Duggan Avenue

More information

MAGPOWR Spyder-Plus-S1 Tension Control

MAGPOWR Spyder-Plus-S1 Tension Control MAGPOWR TENSION CONTROL MAGPOWR Spyder-Plus-S1 Tension Control Instruction Manual Figure 1 EN MI 850A351 1 A COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess International,

More information

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

VECTRIX VX-2 SERVICE MANUAL.   Version 1.0/May 2011 VECTRIX, LLC www.vectrix.com CONTENTS SECTION A: Tools 1 Tools Needed SECTION B: Mechanical Parts 1 Front Fairing 2 Front Console Cover 3 Speedometer Cover 4 Front Vertical Panel Cover-Lower 5 Front Vertical Panel

More information

Introduction. E-Trac Xchange is versatile and easy to use, so make the most of your E-Trac with this great new feature. Enjoy!

Introduction. E-Trac Xchange is versatile and easy to use, so make the most of your E-Trac with this great new feature. Enjoy! User Guide Introduction 2 A significant feature of E-Trac is the inclusion of a USB connection facility, allowing you to connect your E-Trac to a Personal Computer (PC) to download and upload detector

More information

PRSalpha Air Drill (Double Valve)

PRSalpha Air Drill (Double Valve) 888-680-4466 ShopBotTools.com PRSalpha Air Drill (Double Valve) Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Overview...5 Spindle Mounting Plate...6

More information

Hand Held Pull Tester Instruction Manual Order No

Hand Held Pull Tester Instruction Manual Order No Instruction Manual Order No. 63801-9700 Doc. No: TM-638019700 Release Date: 02-21-12 UNCONTROLLED COPY Page 1 of 13 Safety Warnings and Information Read and understand all of the instructions and safety

More information

T H E U L T I M A T E L A S E R D E F E N S E S Y S T E M

T H E U L T I M A T E L A S E R D E F E N S E S Y S T E M S P E E D O F L I G H T P R O T E C T I O N CINCINNATI MICROWAVE 5440 West Chester Road West Chester OH 45069 Sales/Service 800-433-3487 EscortRadar.com 2014 CINCINNATI MICROWAVE. ESCORT, Laser ShifterPro,

More information

DFE PARTS LIST INSTALLATION INSTRUCTIONS PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

DFE PARTS LIST INSTALLATION INSTRUCTIONS PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION 1 Fusion Module 1 USB Cable 1 Installation Guide PARTS LIST INSTALLATION INSTRUCTIONS 2 Velcro Strips 1 Alcohol Swab 1 O2 Optimizer 2014 KAWASAKI TERYX 4 DFE-17-054 PLEASE READ ALL DIRECTIONS BEFORE STARTING

More information

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual Raptor user manual 1 mounting bracket 2 swivel lock 3 clamp hole 4 lamp access screws 5 air vents 2001-2002 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced,

More information

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual Raptor user manual 1 mounting bracket 2 swivel lock 3 clamp hole 4 lamp access screws 5 air vents 6 AC input & main fuse 7 cooling fan Thank you for selecting the Martin Raptor. This Martin lighting fixture

More information

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems IntelliSens App Interactive Guide For Android & ios devices Revision 2.0 17.10.2016 Overview Function flow... 3 HC1000... 4 First Steps... 5 How to Read a Sensor... 7 How to Program a Sensor... 10 Program

More information

SA Series Tape Feeder

SA Series Tape Feeder SA Series Tape Feeder SA Series 1216, 2432 SL Tape Feeder Product Guide All rights reserved Revision A (2) 31 August 2018 0870D-E052 SA Series 1216, 2432 SL Tape Feeder Product Guide Hover-Davis has checked

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: Dec., 2015 Version: 1.1 2 3 What s in the Box CONTENT 2 Screws & Anchors 2 Screwdriver 4 Diode Contents What s in the Box...2 Optional accessories...4

More information

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage. 1. Overview The front panel houses the UV detector lamp switch, Rheodyne injection valve, prime/purge valve, pressure gauge, and the storage compartment. In the storage compartment are the LED display

More information

ZT-USB Series User Manual

ZT-USB Series User Manual ZT-USB Series User Manual Warranty Warning Copyright All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, beginning from the date of delivery

More information

Customer User Guide. ComTrac CUSTOMER USER GUIDE VERSION 0.1

Customer User Guide. ComTrac CUSTOMER USER GUIDE VERSION 0.1 Customer User Guide ComTrac CUSTOMER USER GUIDE VERSION 0.1 Contents 1 How to use this guide... 3 1.1 Confidentiality... 3 1.2 Purpose of this guide... 3 1.3 What s new and what s changed... 3 1.4 User

More information

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION 2011 Honda CBR250R Installation Instructions PARTS LIST 1 Juice Box Pro 1 USB Cable 1 Top Tune CD-ROM 1 Installation Guide 2 Velcro strip 1 Alcohol swab 1 Posi-tap THE IGNITION MUST BE TURNED OFF BEFORE

More information

DriveRight VSS Installation Guide

DriveRight VSS Installation Guide DriveRight VSS Installation Guide Product # 8155VSS, 8155VF, 8160VSS, 8160VF Product Number: 8155VSS, 8155VF, 8160VSS, 8160VF Davis Instruments Part Number: 7395-062 DriveRight VSS Installation Guide Rev.

More information

IDENTIFICATION OF FUEL INJECTION CONTROL SYSTEM IN A GDI ENGINE

IDENTIFICATION OF FUEL INJECTION CONTROL SYSTEM IN A GDI ENGINE Journal of KONES Powertrain and Transport, Vol. 17, No. 4 21 IDENTIFICATION OF FUEL INJECTION CONTROL SYSTEM IN A GDI ENGINE Zbigniew Wo czy ski Technical University of Radom Chrobrego Av. 45, 26-6 Radom,

More information

Online Capacity Tester MK70 User and PC-Software Manual

Online Capacity Tester MK70 User and PC-Software Manual Online Capacity Tester MK70 User and PC-Software Manual User manual Online-Battery-Tester - 2 User manual Online-Battery-Tester - 3 Introduction: With this processor controlled capacity tester you can

More information

Flue Gas Analyzer IMR 1100F

Flue Gas Analyzer IMR 1100F Flue Gas Analyzer IMR Environmental Equipment. Inc. 3634 Central Ave. St. Petersburg Florida 33711 Tel: 727-328-2818 Fax 727-328-2826 info@imrusa.com www.imrusa.com User Manual INTRODUCTION 3 SAFETY INSTRUCTIONS

More information

Simulating Trucks in CORSIM

Simulating Trucks in CORSIM Simulating Trucks in CORSIM Minnesota Department of Transportation September 13, 2004 Simulating Trucks in CORSIM. Table of Contents 1.0 Overview... 3 2.0 Acquiring Truck Count Information... 5 3.0 Data

More information

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents w w w. r o c s o l i d. c o m. a u PowerSTAR PS-2024-D Maximum Power Point Tracking Solar Regulator Contents 1 Quick Start Guide... 2 2 Specifications... 3 2.1 General Operation... 3 2.2 Absolute Maximum

More information

Operating Instructions EVG620 Aligner

Operating Instructions EVG620 Aligner Operating Instructions EVG620 Aligner The tool uses 5 masks only. It can align to small pieces and up to a 4 wafer. Using the Tool for Top Side Alignment 1. Insure that the lamp is glowing by checking

More information

User Manual. Engine and Tank Monitoring Firmware version 1.00e for Text Display YDTD-20N

User Manual. Engine and Tank Monitoring Firmware version 1.00e for Text Display YDTD-20N User Manual Engine and Tank Monitoring Firmware version 1.00e for Text Display YDTD-20N 2016 2016 Yacht Devices Ltd. Document YDTD20-EF-001. September 16, 2016. Web: http://www.yachtd.com/ NMEA 2000 is

More information

Pulsar EXtreme 2200C / 3200C

Pulsar EXtreme 2200C / 3200C www.mgeups.com MGE UPS SYSTEMS Pulsar EXtreme 00C / 300C Installation and user manual P O W E R P R O V I D E R L E I B E R R U P T N T N I E U T H 3400753EN/AA - Page Introduction Thank you for selecting

More information

Thermo Scientific APEX 500 Rx Metal Detector User s Guide. REC 4345 Rev B Part number English

Thermo Scientific APEX 500 Rx Metal Detector User s Guide. REC 4345 Rev B Part number English Thermo Scientific APEX 500 Rx Metal Detector User s Guide REC 4345 Rev B Part number 109541 English 2010 Thermo Fisher Scientific, Inc. All rights reserved For future reference, write your APEX 500 Rx

More information

OEM TM-50 Quick Start Guide

OEM TM-50 Quick Start Guide This quick start guide provides basic setup and operating instructions for the OEM TM-50. The intended use of the OEM TM-50 Taping Machine is to produce taped reels of individually sealed and consistently

More information

Indian Speedometer and Body Control Module Service Tool Users Guide

Indian Speedometer and Body Control Module Service Tool Users Guide Indian Speedometer and Body Control Module Service Tool Users Guide Installing speedometer software to your computer 1. Go to the Indian Motorcycle Website: WWW. Indianmotorcycle.com 2. Log in to Service

More information

IBM UPS Extend Run Battery Pack Operation and Setup Guide

IBM UPS Extend Run Battery Pack Operation and Setup Guide IBM UPS Extend Run Battery Pack Operation and Setup Guide 02R2717 1: INSTALLATION Introduction The IBM Uninterruptible Power Supply (UPS) Extend Run Battery Pack provides extended load protection and

More information

Overview of operation modes

Overview of operation modes Overview of operation modes There are three main operation modes available. Any of the modes can be selected at any time. The three main modes are: manual, automatic and mappable modes 1 to 4. The MapDCCD

More information

Universal Wireless Dashboard Y-Dash + Android App Y-Dash GT. User Manual Firmware version 1.6 Software version 2.28 Hardware version 1.

Universal Wireless Dashboard Y-Dash + Android App Y-Dash GT. User Manual Firmware version 1.6 Software version 2.28 Hardware version 1. Universal Wireless Dashboard + Android App GT User Manual Firmware version 1.6 Software version 2.28 Hardware version 1.3 Page 2 is an electronic microprocessor based device that collects analog and digital

More information

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor. Mission Planner Setup ( optional, do not use if you have already completed the Dashboard set-up ) Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

More information

Model DS7060 Handrail Scale. User Manual

Model DS7060 Handrail Scale. User Manual Model DS7060 Handrail Scale User Manual Doran Scales, Inc. 1315 Paramount Pkwy Batavia, IL 60510 USA 1-800-264-4107 www.doranmedical.com MAN0302 Revision 0.0 TNW 2/20/2013 Section 1. Unpacking and Installation...

More information

INTELLIQUILTER INSTALLATION ON PRODIGY VERSION

INTELLIQUILTER INSTALLATION ON PRODIGY VERSION INTELLIQUILTER INSTALLATION ON PRODIGY VERSION 05.09.16 1. COMPUTER BRACKET Remove the drop-in nuts from the tablet mounting bracket and insert them in the slots at the top of the upper arm, just behind

More information

Controller Ground (dual black 12awg) should be connected to chassis ground as close as possible to the battery.

Controller Ground (dual black 12awg) should be connected to chassis ground as close as possible to the battery. 1. Overview The Maximizer 4 progressive nitrous controller operates one or two separate stages of nitrous based on either time, RPM, MPH, throttle percentage or boost pressure. Whether your engine is naturally

More information

Genesys 20 Calibration and Maintenance

Genesys 20 Calibration and Maintenance NOTICE: This document is version controlled and was produced as a part of the GEX Information Program which requires that all Series 100 documents be reviewed periodically to maintain currency and continuity

More information

STRESS-TEK, INC S. 194 th Street Kent, WA June 2011 Stress-Tek, Inc. Doc Rev A

STRESS-TEK, INC S. 194 th Street Kent, WA June 2011 Stress-Tek, Inc. Doc Rev A Installation, Setup and Calibration of Vulcan Deflection Sensors on Hendrickson 462/463 and Haulmaxx Equalizing Suspension Beams (Includes Models HN 402, HN 462, HN FR, RT 463, RTE 463, HMX and HMX 400.)

More information

READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING TC-6 TC-15 TC Fax

READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING TC-6 TC-15 TC Fax OPERATING MANUAL TC-6, TC-15A & TC16 FILTER CRUSHER TC-6 TC-15 TC-16 READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING Oct. 18, 2012 800.223.4540 3451 S. 40th Street Phoenix, AZ 85040 602.437.5020 www.tssissg.com

More information

TachoDrive key + TachoDrive Express software

TachoDrive key + TachoDrive Express software TachoDrive key + TachoDrive Express software Instruction manual November 2007 v 1.01 MATT 2007 All rights reserved Table of contents 0. Introduction...4 1. TachoDrive device...5 1.1 General description...5

More information

Educational Robot. Revision 2.0

Educational Robot.  Revision 2.0 Educational Robot www.ridgesoft.com Revision 2.0 IntelliBrain-Bot Assembly Guide 1 Introduction This document provides instructions to guide you through assembly of your IntelliBrain -Bot. It takes approximately

More information

INSTALLATION MANUAL AP60B INSTALLATION MANUAL

INSTALLATION MANUAL AP60B INSTALLATION MANUAL INSTALLATION MANUAL 2. TOOLS REQUIRED The following is a list of tools required to properly install the cruise control. While this unit may be installed without some of the tools listed, it is recommended

More information

for Autonomous Operation Quick User s Guide SOR SOR Quick User s Guide for Autonomous Operation Rev 1

for Autonomous Operation Quick User s Guide SOR SOR Quick User s Guide for Autonomous Operation Rev 1 Quick User s Guide for Autonomous Operation SOR SOR Quick User s Guide for Autonomous Operation 15-00079 Rev 1 1 The SOR Series Electronic Dosimeter Welcome! The SOR/R and its sister products (DMC 2000

More information

ELD DRIVER GUIDE June 21, 2018

ELD DRIVER GUIDE June 21, 2018 ELD DRIVER GUIDE June 21, 2018 Contents Getting Started with PrePass ELD...4 Enroll in the PrePass ELD Program... 4 For a Carrier Enroll in the ELD Service... 4 For a Driver Get Driver Login Information...

More information

ROW PRO DOWN PRESSURE

ROW PRO DOWN PRESSURE Operator s Manual ROW PRO DOWN PRESSURE VERSION 2 & 3 Safety Notices... 1 Disclaimer... 1 Row-Pro Down Pressure... 3 Requirements... 3 Setup... 4 Control Mode... 4 Disable Down Pressure Modules... 7 Setting

More information

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt Note: Indented items indicate parts included in an assembly listed above. Part Name/Description Part Number Quantity Direct Command Kit 4100514 1 Installation Instructions 2005690 1 CAN Y-Splice 4000137

More information

TECHNICAL BULLETIN No:

TECHNICAL BULLETIN No: Date: 18 Jul 2006 CIRCULATE: TO Service Mgr Warranty Workshop Body Shop Parts X X X X X CHANGES MADE FOR ISSUE "3" ARE HIGHLIGHTED WITH GREY BACKGROUND SECTION: 204-05 Electronic Air Suspension Fault Codes

More information

Adaptronic esel020 Select ECU for Nissan S13 240SX (KA24DE) / RNN14 GTiR / SR20VE

Adaptronic esel020 Select ECU for Nissan S13 240SX (KA24DE) / RNN14 GTiR / SR20VE 1 P a g e Adaptronic esel020 Select ECU for Nissan S13 240SX (KA24DE) / RNN14 GTiR / SR20VE Applicable vehicles / engines: Nissan S13 KA24DE 240SX US Market Nissan N14 SR20DET / SR20VE - Pulsar GTi-R /

More information

WANHAO Duplicator i3. User Manual V1.2. Wanhao USA

WANHAO Duplicator i3. User Manual V1.2. Wanhao USA WANHAO Duplicator i3 User Manual V1.2 Wanhao USA 2015 www.wanhaousa.com Safety WARNING: The components on the Duplicator i3 generate high temperatures and move extremely fast. Reaching inside of the Duplicator

More information

Manifold w/ Needle Valve Instruction Manual

Manifold w/ Needle Valve Instruction Manual MODELS: MFC2 & MFC4 Manifold w/ Needle Valve Instruction Manual SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 - Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com

More information

INDEX. 1.Safety Precautions and Warnings...3

INDEX. 1.Safety Precautions and Warnings...3 INDEX 1.Safety Precautions and Warnings...3 2. General Information...5 2.1 On-Board Diagnostics (OBD) II... 5 2.2 Diagnostic Trouble Codes (DTCs)... 6 2.3 Location of the Data Link Connector (DLC)...7

More information

Agilent G4236A 2D-LC Valve Installation Guide

Agilent G4236A 2D-LC Valve Installation Guide Agilent G4236A 2D-LC Valve Installation Guide Technical Note Contents Delivery Checklist 2 Installing Valve Heads 3 Removing the Transportation Lock and the Valve Dummy 3 Installing the Valve Head and

More information

WindLab TM Wind Turbine Power System Sample Laboratory Procedure Manual

WindLab TM Wind Turbine Power System Sample Laboratory Procedure Manual WindLab TM Wind Turbine Power System Sample Laboratory Procedure Manual WindLab TM is a scaled Wind Turbine Electrical Generation System, designed to function like a full-sized wind turbine system. It

More information

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16 User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...

More information