GRUNDFOS PRODUCT GUIDE. Submersible pumps, motors, and accessories 60 Hz

Size: px
Start display at page:

Download "GRUNDFOS PRODUCT GUIDE. Submersible pumps, motors, and accessories 60 Hz"

Transcription

1 GRUNDFOS PRODUCT GUIDE Submersible pumps, motors, and accessories 6 z

2 Table of contents 1. Product introduction 3 Introduction 3 Applications 3 Features and benefits 3 Identification 8 2. Product overview 9 Performance range 6 z 9 Pump range 1 Motor range 1 Motor protection and controllers 1 3. Construction Operating conditions 18 Operating conditions 18 Curve conditions ow to read the curve charts S (7 gpm) 22 1S (1 gpm) 24 16S (16 gpm) 26 25S (25 gpm) 28 4S (4 gpm) 3 6S (6 gpm) 32 75S (75 gpm) 34 85S (85 gpm) 36 15S (15 gpm) 42 23S (23 gpm) 48 3S (3 gpm) S (385 gpm) 6 625S (625 gpm) 7 8S (8 gpm) 75 11S (11 gpm) 8 Electrical data Accessories 86 MP Control functions 89 G1 gateway for communication with Grundfos products 92 Connecting pieces 94 Zinc anodes 95 SA-M 5 control boxes 95 Pt Energy consumption 98 Energy consumption of submersible pumps Cables 99 Cable sizing chart 1 1. Friction loss tables Further product documentation 14 WebCAPS 14 WinCAPS 15 2

3 1 1. Product introduction Introduction The Grundfos range of submersible pumps is renowned for high efficiency and reliability. Made entirely of corrosion resistant stainless steel, pumps are ideal for a wide variety of applications. Grundfos pumps represent state-of-the-art hydraulic design. Built to deliver optimum efficiency during periods of high demand, pumps provide low long-term costs and high operating reliability regardless of the application. The range offers high efficiency, high resistance to sand and other abrasives, motor burnout protection, and easy maintenance. A complete monitoring and control system is available for constant optimization of the pumping system. Applications Grundfos Large submersible pumps are suitable for: Groundwater supply to waterworks Irrigation in horticulture and agriculture Groundwater lowering (dewatering) Pressure boosting Industrial applications Domestic water supply. Pumped liquids Grundfos pumps are suitable for pumping clean, thin, non-aggressive liquids without solid particles or fibers. offers stainless steel construction which ensures good wear resistance and a reduced risk of corrosion where the water has minor chloride content. Optional, upgraded stainless steel construction is available for pumping more aggressive liquids: A complete range of zinc anodes for cathodic protection is available; see p. 97 for applications (for example, sea water applications). For slightly polluted liquids (for example, containing oil), Grundfos offers a complete range of stainless steel NE pumps with all rubber parts made of FKM. Product introduction Features and benefits Fig. 1 Grundfos pumps TM Grundfos submersible pumps offer these features and benefits: State-of-the-art hydraulics provide high efficiency and low operating costs 1 % stainless steel components inside and outside for long service life Sand resistant Resistant to aggressive water Dry-running protection Monitoring, protection and communication via protection unit M4, and remote control, R1. 3

4 1 Product introduction A wide pump range Grundfos offers energy-efficient submersible pumps with a performance range of up to 1,4 gpm and 2,1 ft of head. The pump range consists of many pump sizes, and each pump size is available with an optional number of stages to match any duty point. igh pump efficiency Often pump efficiency is given less consideration than the price of a pump; however, owners who choose efficiency will find substantial savings in energy costs over time. See fig. 2 for an illustration of efficiencies in relation to flow. Example For example, a pump and motor with a 1 % higher efficiency than a cheaper, less efficient pump, can save its owner more than $8,. over 1 years*. * If producing 88 gpm at 325 ft of head for cents per kwh. U.S. kwh costs range from 6 cents to more than 2 cents, depending on region. Eff [%] Fig. 2 5S 1S 16S 25S 4S 75S 85S Q [US GPM] 15S 23S 3S 6 Z 385S 475S 625S 8S 11S pump/motor efficiencies in relation to flow TM Pump design Grundfos submersible pumps feature components that contribute to the superior performance and durability of the range. Lower installation costs Stainless steel means low weight for ease in the handling of pumps, resulting in lower equipment costs and reduced installation and service time. Bearings with sand channels All bearings are water-lubricated and have a squared shape enabling sand particles, if any, to leave the pump together with the pumped liquid. Fig. 3 Bearing Inlet strainer The inlet strainer prevents particles over a certain size from entering the pump. Fig. 4 Fig. Inlet strainer Non-return valve All pumps are equipped with a reliable check valve in the valve casing preventing back flow in connection with pump stoppage. Furthermore, the short closing time of the check valve means that the risk of destructive water hammer is reduced to a minimum. The valve casing is designed for optimum hydraulic properties to minimize the pressure loss across the valve and thus to contribute to the high efficiency of the pump. TM TM Fig. 5 Check valve Valve flap TM

5 1 Priming screw All Grundfos 4" pumps are fitted with a priming screw. Consequently, dry running is prevented, because the priming screw will make sure that pump bearings are always lubricated. Due to the semi-axial impellers of large pumps this priming is provided automatically. owever, it applies to all pump types that if the water table is lowered to a level below the pump inlet neither pump nor motor will be protected against dry running. Fig. 6 Stop ring Priming screw The stop ring prevents damage to the pump during transport and in case of up-thrust in connection with start-up. The stop ring, which is designed as a thrust bearing, limits axial movements of the pump shaft. Example: 385S The stationary part of the stop ring (A) is secured in the upper intermediate chamber. The rotating part (B) is fitted above the split cone (C). A B TM Grundfos submersible motors A complete motor range Grundfos offers a complete submersible motor range in different voltages. For an overview of motor types, sizes and voltages, see page 85. MS 42 is designed for the domestic ground water market and covers outputs. The MS 4 and MS6 series are designed for use in a variety of applications in water supply. When equipped with features like oversized motor, temperature measurement, cooling jacket, and SiC/SiC mechanical shaft seals, these motors are suitable for heavy-duty industrial applications such as dewatering operations. As a standard, all external surfaces of the Grundfos MS motors in contact with water are made of AISI 34 stainless steel. For aggressive water, such as seawater or brackish water, R-versions made of AISI 94 are available. Grundfos rewindable MMS motor range Grundfos MMS motors are suitable for any submersible installation, including heavy-duty industrial applications and dewatering operations (when equipped with temperature control, oversized motor, cooling jacket, and SiC/ SiC mechanical shaft seals). As a standard the MMS motors are supplied with black cast-iron end-bells. Optionally, the range is available in all-stainless steel AISI 316 or AISI 94 versions. The 2-pole Grundfos MMS submersible motors are all easy to rewind. The windings of the stator are made of a special water-proof wire of pure electrolytic copper sheathed with special non-hydroscopic thermoplastic material. The fine dielectric properties of this material allow direct contact between the windings and the liquid for efficient cooling of the windings. Product introduction Fig. 7 Stop ring (rotating and stationary part) and the split cone C TM Fig. 8 Grundfos MS motors TM GrA411 - GrA413 5

6 1 Product introduction Fig. 9 Grundfos MMS motors Industrial submersible motors and MS6 T6-versions For heavy-duty applications Grundfos offers a complete motor range of industrial motors with up to 5 % higher efficiency than that of Grundfos' standard motors. The industrial motors are available in sizes as from 3 p up to 3 p. The cooling of the motor is very efficient due to the large motor surface. The efficient cooling makes it possible to increase the liquid temperature to 14 F (6 C) at a minimum flow of.49 ft/s (.15 m/s) past the motor. The industrial motors are for customers who value low operating costs and long life higher than price. Grundfos industrial motors are developed for difficult operating conditions. These motors will stand a higher thermal load than standard motors and thus have a longer life when subjected to high load. This applies whether the high load is caused by bad power supply, hot water, bad cooling conditions, high pump load etc. Please note that heavy duty motors are longer than motors for standard conditions. TM Overtemperature protection Accessories for protection against overtemperature are available for both Grundfos MS and MMS submersible motors. When the temperature becomes too high, the protection device will cut out and damage to the pump and motor be avoided. Restart of the motor after cut-out can be achieved in two ways: manual restart automatic restart. Automatic restart means that the MP 24 attempts to restart the motor after 15 minutes. If the first attempt is not successful, restarting will be reattempted at 3-minute intervals. MS The Grundfos MS submersible motors (with the exception of MS 42) are available with a built-in Tempcon temperature transmitter for protection against overtemperature. By means of the transmitter, it is possible to read out and/or monitor the motor temperature via an MP 24 or a PR 5714 relay. The Grundfos MS6 submersible motors can be fitted with a Pt1. The Pt1 is fitted in the motor and connected directly to the MP 24 or monitored by the PR 5714 relay. MMS For the protection of the Grundfos MMS submersible motors against overtemperature Grundfos offers the Pt1 temperature sensor as an optional extra. The Pt1 is fitted in the motor and connected directly to the MP 24 or monitored by the PR 5714 relay. Protection against upthrust In case of a very low counter pressure in connection with start-up there is a risk that the entire chamber stack may rise. This is called upthrust. Upthrust may damage both pump and motor. Both Grundfos pumps and motors are protected against upthrust as standard, preventing upthrust from occurring during the critical start-up phase. The protection consists of either a built-in stop ring or hydraulic balancing. Built-in cooling chambers In all Grundfos MS submersible motors, efficient cooling is ensured by cooling chambers at the top and at the bottom of the motor, and by an internal circulation of motor liquid. See fig. 1. As long as the required flow velocity past the motor is maintained, cooling of the motor will be efficient. 6

7 1 MMS rewindable motors The standard shaft seal is a ceramic/carbon mechanical shaft seal. The shaft seal is replaceable. The material features good wear resistance and resistance to particles. Together with the shaft seal housing, the sand shield forms a labyrinth seal, which during normal operating conditions prevents penetration of sand particles into the shaft seal. On request, motors can be supplied with a SiC/SiC seal. TM Product introduction Fig. 1 MS 4 Lightning protection The smallest Grundfos submersible motors, such as the MS 42, are all insulated in order to minimize the risk of motor burnout caused by lightning strike. Reduced risk of short-circuit The embedded stator winding in the Grundfos MS submersible motor is hermetically enclosed in stainless steel. The result is high mechanical stability and optimum cooling. Also, this eliminates the risk of short-circuit of the windings caused by water condensation. Shaft seal MS 42 The shaft seal is of the lip seal type characterized by low friction against the rotor shaft. The rubber material offers good wear resistance, good elasticity and resistance to particles, and it is approved for use in drinking water. MS 4, MS6 The material is ceramic/tungsten carbide providing optimum sealing, optimum wear resistance and long life. The spring loaded shaft seal is designed with a large surface and a sand shield. The result is a minimum exchange of pumped and motor liquids and no penetration of particles. Motors, version R, are supplied with a SiC/SiC shaft seal. Other combinations are available request. See fig. 11 and fig. 12 for an illustration of shaft seal components and configuration. Fig. 11 Shaft seal, MS 4 Fig. 12 Shaft seal, MS6 TM TM

8 1 Product introduction Identification Type key, pumps Example 475 S A B Rated flow rate in gpm Type range Stainless steel parts of material S= AISI 34 N= AISI 316 R= AISI 94L p of motor Number of impellers First reduced-diameter impeller (A, B or C) Second reduced-diameter impeller (A, B or C) Type key, MS 4 motors Example MS 4 R Motor submersible Min. borehole diameter in inches Generation - = Stainless steel AISI 34 R = Stainless steel AISI 94L I = Stainless steel AISI 34 + De-rated RE = Stainless steel AISI 94 L + FKM EI = Stainless steel AISI 34 + De-rated + FKM Type key, MS 42 motors Example MS 4 2 Motor submersible Min. borehole diameter in inches Generation Type key, MMS motors Example MMS 6 N Type range Min. borehole diameter in inches Generation - = Stainless steel AISI 34 Material: = Cast iron EN-JL14 N = DIN/EN (AISI 316) Type key, MS6 motors Example MS 6 R E S W D T6 Type range (Motor Submersible) Motor diameter in inches Material Blank = stainless steel EN (AISI 34) R = stainless steel EN (AISI 94L) Rubber parts Blank = NBR E = FKM Shaft seal Blank = ceramics/carbon S = SiC/SiC Radial bearings Blank = carbon/stainless steel W = SiC/tungsten carbide Motor liquid Blank = SML-3 D = demineralized water Maximum liquid temperature T3 = 86 F (3 C) T6 = 14 F (6 C) 8

9 2 2. Product overview Performance range 6 z [m] z, SF 1.15 Product overview S 1S 16S 25S 4S 6S 75S 85S 15S 23S 3S 385S 475S 625S 8S 11S Q [US GPM] Q [m³/h] TM

10 2 Product overview Pump range Type 5S 1S 16S 25S 4S 6S 75S 85S 15S 23S 3S 385S 475S 625S 8S 11S AISI 34 stainless steel AISI 316 stainless steel AISI 94L stainless steel Connection NPT 1" 1.25" 1.25" 1.5" 2" 2" 2" (3") (3") Flange connection: Grundfos flange 3" (4") 3" 4" 5" 5" 6" 6" 6" 5" 5" 6" 6" 6" Figures in brackets ( ) indicate connection for pumps with sleeve. Motor range Motor output [hp] Single-phase Three-phase Industrial motor and MS6 T6-versions Direct-on-line starting is recommended up to 1 hp. Soft starter or autotransformer is recommended above 1 hp. Motors with star/delta are available from 7.5 hp. Motor protection and controllers Rewindable motor Steel: AISI 34 Steel: AISI 34 and cast iron Steel: AISI 316 Steel: AISI 94L Built-in temperature transmitter in motor Motor output [hp] MP 24 Pt1 Zinc anode Vertical flow sleeve orizontal flow sleeve SA-M R1 RS-485 communication module G1 Motor protection of single-phase motors, see page 85. 1

11 3 3. Construction Sectional drawing, pump, 4" b b Material specification, pump, 4" Pos. Component Materials Standard AISI 1 Valve casing Stainless steel 34 1b Discharge piece Stainless steel 34 2 Valve cup Stainless steel 34 3 Valve seat Stainless steel/nbr 34 6 Top bearing NBR 7 Neck ring NBR/PBT 8 Intermediate ring NBR 9 1 Intermediate chamber Bottom intermediate chamber Stainless steel 34 Stainless steel Impeller Stainless steel Suction interconnector Stainless steel Shaft Stainless steel Strap Stainless steel Cable guard Stainless steel exagon screw Stainless steel 34 19a Nut Stainless steel b Nut Stainless steel 34 2 Motor cable 64 Priming disc Stainless steel 34 7 Valve guide Stainless steel Washer for pos. 19 Stainless steel Washer Stainless steel Nameplate Stainless steel ook Stainless steel 34 Construction 18 TM Fig. 13 pump, 4" 11

12 3 Construction Sectional drawing, pump, 6" 1 Material specification, pump, 6" Standard N-version R-version Pos. Component Materials AISI Valve casing 1 Valve casing Stainless steel L 2 3 1a 2 Valve cup Stainless steel L 3 Valve seat Stainless steel L 4 Top chamber Stainless steel L 4 Chamber stack 6 7 Neck ring NBR/PPS 8 Bearing NBR a Spacing washer Carbon/ graphite Y22 in PTFE mass 9 Chamber Stainless steel L 11 Nut for split cone Stainless steel L Split cone Stainless steel L 8a 13 Impeller Stainless steel L 16 Shaft with coupling Stainless steel Si Cable guard Stainless steel L Rubber guard NBR 25 Neck ring retainer Stainless steel L 64 Priming screw Stainless steel L 72 Wear ring Stainless steel L Suction interconnector Suction interconnector Stainless steel L 19 Fig. 14 pump, 6" TM Intermediate piece for 6" motor over 4 p Stainless steel Strainer Stainless steel L 17 Strap Stainless steel L 19 Nut for strap Stainless steel L 19a Nut Stainless steel Motor cable 78 Nameplate Stainless steel Pumps in sleeve Clamping flange (counter) Stainless steel L Clamping flange Stainless steel L Connecting piece Stainless steel L Sleeve Stainless steel L Stay bolt Stainless steel L exagon socket head screw Stainless steel L 12

13 3 Sectional drawing, pump, 8" Material specification, pump, 8" Pos. Component Materials Standard N-version R-version AISI 1 Valve casing Stainless steel L 1d O-ring NBR Construction 2 Valve cup Stainless steel L 8a 11c b 3 1d 3a 6 8b 4 3 Valve seat 3a 3b Lower valve seat retainer Upper valve seat retainer Standard/ N- version: NBR R-version: FKM Stainless steel (DIN ) Stainless steel L 4 Top chamber Stainless steel L 6 Upper bearing Stainless steel/nbr 7 Neck ring NBR/PPS 8 Bearing NBR 8a Washer for stop ring Carbon/ graphite Y22 in PTFE mass L 8b Stop ring Stainless steel L 9 Chamber Stainless steel L Split cone nut Stainless steel L 11c Nut for stop ring Stainless steel L 12 Split cone Stainless steel L 13 Impeller Stainless steel L Suction interconnector Stainless steel CF8M A744 CD4-MCu (DIN ) 15 Strainer Stainless steel L 16 Shaft complete Stainless steel Strap Stainless steel L Cable guard Stainless steel L 19 Nut for strap Stainless steel L 39 Spring for valve cup Stainless steel SAF Valve guide Stainless steel L TM Washer Stainless steel L 72 Wear ring Stainless steel L Fig. 15 pump, 8" 13

14 3 Construction Sectional drawing, pump, 1" 13 13a 13b b 3 1d 3a Material specification, pump, 1" Pos. Description Material Valve casing Standard AISI N version 1 Valve casing Stainless steel d O-ring NBR 2 Valve cup Stainless steel Valve seat Stainless steel a 3b Lower valve seat retainer Upper valve seat retainer Stainless steel Stainless steel Spring for valve cup Stainless steel Valve guide Stainless steel Nameplate Stainless steel Rivet Stainless steel Connecting piece Stainless steel Chamber stack 4 Top chamber Stainless steel Upthrust disc 6 Top bearing Carbon/ graphite Y22 in PTFE mass Stainless steel/ NBR 7 Neck ring NBR/PPS 8 Bearing NBR Chamber Stainless steel Nut for split cone Stainless steel Split cone Stainless steel Impeller Stainless steel Shaft with coupling Stainless steel Cable guard Stainless steel a, 18b Screw for cable guard Stainless steel Rubber guard NBR 72 Wear ring Stainless steel Suction interconnector TM Suction interconnector Stainless steel Strainer Stainless steel Strap Stainless steel Nut for strap Stainless steel a Nut Stainless steel Motor cable 22 Bolts Stainless steel , 28a Lock for strainer Stainless steel Fig. 16 pump, 1" 14

15 3 Sectional drawing - MS motors Material specification, MS 42 and MS 4 motors Pos. Part R-version motor MS 42 MS 4 AISI 1 Shaft Shaft seal NBR Tungsten carbide/ ceramic 3 Motor sleeve Motor end shield 34 5 Radial bearing Ceramic Ceramic/ tungsten carbide 6 Axial bearing Ceramic/carbon Ceramic/carbon Rubber parts NBR NBR Construction Pos. Part MS TM Shaft 318 LN 2 Shaft seal NBR/ceramic 3 Motor sleeve 94L 4 Motor end shield 94L 5 Radial bearing Ceramic/tungsten carbide 6 Thrust bearing Ceramic/carbon Rubber parts NBR Fig. 17 MS 42 motor Fig. 18 MS 4 motor 6 4 TM

16 3 Construction Sectional drawing - MS6 motors 1 2 Material specification - MS6 motors Pos. Part MS6 22 Shaft with rotor 318LN 2 Shaft seal Ceramic/carbon 3 Motor sleeve 34 4 Motor end cover 34 Rubber parts NBR/FKM R-version motor Pos. Part MS6 1 Shaft 318LN 2 Shaft seal SiC/SiC 3 Motor sleeve 94L 4 Motor end cover (DIN ) Rubber parts FKM 3 4 TM Fig. 19 MS6 motor 16

17 3 Sectional drawing - MMS motors 22 Material specification MMS motors, submersible rewindable versions Pos. Component Material AISI 22 Shaft Steel (EN 1.533) Construction 22a Shaft ends Stainless steel 316/ / 26 Thrust bearing Stationary/ rotating part 6",.5-2 p ardened steel/ EPDM 6", 25-5 p Ceramic/ 8" - 1" carbon 24 Bearing bush 6" - 1" Carbon 22a 25 Bearing housing, upper Cast iron A126 Class B 212 Diaphragm CR 213 Motor end shield Cast iron A126 Class B 218 Motor sleeve Stainless steel Motor cable EPDM Shaft seal Ceramic/ carbon 235 Intermediate housing Cast iron A126 Class B 236 Bearing housing, lower Cast iron A126 Class B MMS motors, N- and R-versions Version 218 Pos. Component Material N R* AISI 22a Shaft Steel (EN 1.533) * Only MMS 6 and MMS 8 are available in R-versions (EN 1.533) 22a Shaft ends Stainless steel 316/ LN 23/ 26 Thrust bearing Stationary/ rotating part 6",.5-2 p ardened steel/epdm 6", 25-5 p Ceramic/ 8"-1" carbon 24 Bearing bush 6"-1" Carbon 25 Bearing housing, upper Stainless steel L 212 Diaphragm CR 213 Motor end shield Stainless steel L 218 Motor sleeve Stainless steel L 22 Motor cable EPDM 226 Shaft seal Ceramic/ carbon 235 Intermediate housing Stainless steel L 236 Bearing housing, lower Stainless steel L 212 TM Fig. 2 MMS 1 17

18 4 Operating conditions 4. Operating conditions Operating conditions Flow rate, Q: gpm ( m 3 /h). ead, : Maximum 2657 ft (81 m). Maximum liquid temperature Motor Grundfos MS 4"and MS6 T3-versions Grundfos 4" MS industry versions Grundfos MS6 T6-versions Grundfos MMS 6" to 12" rewindable with PVC in the windings Grundfos MMS 6" to 12" rewindable with PE/PA in the windings Note: Note: For MMS 6,.5 hp; MMS 8, 15 hp; the maximum liquid temperature is 9 F (5 C) lower than the values stated in the table. For MMS 1, 25 hp, the temperature is 18 F (1 C) lower. Operating pressure Motor Grundfos MS 4" and 6" Grundfos MMS 6" to 1" rewindable Flow velocity past motor.49 ft/s (.15 m/s).49 ft/s (.15 m/s) 3.28 ft/s (1. m/s).49 ft/s (.15 m/s) 1.64 ft/s (.5 m/s).49 ft/s (.15 m/s) 1.64 ft/s (.5 m/s) Installation Vertical [ F ( C)] orizontal [ F ( C)] 86 (3) 86 (3) 14 (6) 14 (6) 14 (6) 14 (6) 77 (25) 77 (25) 86 (3) 86 (3) 14 (4) 14 (4) 113 (45) 113 (45) Maximum operating pressure 87 psi (6 Mpa) (6 bar) Curve conditions The conditions below apply to the curves shown on pages 2-84: General Curve tolerances according to ISO 996, Annex A. The performance curves show pump performance at actual speed, cf. standard motor range. The speeds of the motors are approximately these: 4" motors: n = 347 min -1 6" motors: n = 346 min -1 8" to 1" motors: n = 3525 min -1 The measurements were made with airless water at a temperature of 68 F (2 C). The curves apply to a kinematic viscosity of 1 mm 2 /s (1 cst). When pumping liquids with a density higher than that of water, use motors with correspondingly higher outputs. The bold curves indicate the recommended performance range. The performance curves are inclusive of possible losses such as non-return valve loss. Q/: The curves are inclusive of valve and inlet losses at the actual speed. Operation without non-return valve will increase the actual head at rated performance by.5 to 1. m. NPS: The curve is inclusive of pressure loss in the suction interconnector and shows required inlet pressure. Power curve: P 2 shows pump power input at the actual speed of each individual pump size. Efficiency curve: Eta shows pump stage efficiency. If Eta for the actual pump size is needed, please consult WinCAPS or WebCAPS. 18

19 5 5. ow to read the curve charts Number of stages. First figure: number of stages; second figure: number of reduced-diameter impellers. [m] DS -39DS -31 5S 6 z, SF 1.15 ISO 996 Annex A Pump type, number of poles and frequency. Q curve for the individual pump. The bold curves indicate the recommended performance range for best efficiency. ow to read the curve charts The efficiency curve shows the efficiency of the pump. The efficiency curve is an average curve of all the pump types shown in the chart. The efficiency of pumps with reduced-diameter impellers is approx. 2 % lower than the efficiency curve shown in the chart. 1 5 [kw] [hp] Q [US GPM] Q [m³/h] Eff [%] Eff Q [US GPM] The power curves indicate pump input power per stage. Curves are shown for complete (1/1) and for reduced-diameter (2/3) impellers. TM

20 6 6. 5S (5 gpm) [m] DS (3 hp) 5S 6 z, SF 1.15 ISO 996 Annex A DS (2 hp) (1.5 hp) -26 (1.5 hp) -22 (1 hp) (.75 hp) (.5 hp) -9 (.5 hp) Q [US GPM] [kw] Q [m³/h] [hp] Eff.8 Eff [%] Q [US GPM] TM

21 6 5S (5 gpm) Pump model Nom. head Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 5S, motor dia. 4 inch, 2 wire motor, 6 z - rated flow 5 gpm (1" NPT) Net weight (complete) [lb] 5S (624) 11.3 (28) (344) 3.74 (95) 3.97 (11) S (78) 11.3 (28) (428) 3.74 (95) 3.97 (11) (78) 11.3 (28) (428) 3.74 (95) 3.97 (11) S (828) (295) 2.99 (533) 3.74 (95) 3.97 (11) S (927) (31) 24.3 (617) 3.74 (95) 3.97 (11) S (149) (348) 27.6 (71) 3.74 (95) 3.97 (11) S NPT 5S (1199) (348) (851) 3.74 (95) 3.97 (11) S, motor dia. 4 inch, 3 wire motor, 6 z - rated flow 5 gpm (1" NPT) 5S (624) 11.3 (28) (344) 3.74 (95) 3.97 (11) (78) 11.3 (28) (428) 3.74 (95) 3.97 (11) S (78) 11.3 (28) (428) 3.74 (95) 3.97 (11) 25.2 TM S (828) (295) 2.99 (533) 3.74 (95) 3.97 (11) 28.8 E = Maximum diameter of pump 5S (927) (31) 24.3 (617) 3.74 (95) 3.97 (11) 32.4 including cable guard and motor (149) (348) 27.6 (71) 3.74 (95) 3.97 (11) S S S2-39DS 663 5S3-48DS (111) (31) 27.6 (71) 3.74 (95) 3.97 (11) (111) (31) 27.6 (71) 3.74 (95) 3.97 (11) (1199) (348) (851) 3.74 (95) 3.97 (11) (1161) (31) (851) 3.74 (95) 3.97 (11) (1161) (31) (851) 3.74 (95) 3.97 (11) (1514) (495) 4.12 (119) 3.74 (95) 3.97 (11) (1367) (348) 4.12 (119) 3.74 (95) 3.97 (11) (1367) (348) 4.12 (119) 3.74 (95) 3.97 (11) (1782) 22.6 (574) (128) 3.74 (95) 3.97 (11) (1665) 18. (457) (128) 3.74 (95) 3.97 (11) (1665) 18. (457) (128) 3.74 (95) 3.97 (11) 77.4 Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. DS designation = Built into sleeve, 1-1/4" NPT, 6" minimum well diameter. Performance conforms to ISO (E) Annex A. Minimum submergence is 2 feet. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 21

22 6 7S (7 gpm) [m] (2 hp) -26 (1.5 hp) 7S 6 z, SF 1.15 ISO 996 Annex A (1 hp) (.75 hp) (.5 hp) (.5 hp) Q [US GPM] [kw] Q [m³/h] [hp].1 Eff.8 Eff [%] Q [US GPM] TM

23 6 7S (7 gpm) Pump model Nom. head Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 7S, motor dia. 4 inch, 2 wire motor, 6 z - rated flow 7 gpm (1" NPT) Net weight (complete) [lb] 7S (63) 11.3 (28) (323) 3.74 (95) 3.97 (11) S (666) 11.3 (28) 15.2 (386) 3.74 (95) 3.97 (11) (666) 11.3 (28) 15.2 (386) 3.74 (95) 3.97 (11) S (765) (295) (47) 3.74 (95) 3.97 (11) S (864) (31) (554) 3.74 (95) 3.97 (11) S (149) (348) 27.6 (71) 3.74 (95) 3.97 (11) S NPT 7S, motor dia. 4 inch, 3 wire motor, 6 z - rated flow 7 gpm (1" NPT) 7S (63) 11.3 (28) (323) 3.74 (95) 3.97 (11) (666) 11.3 (28) 15.2 (386) 3.74 (95) 3.97 (11) S (666) 11.3 (28) 15.2 (386) 3.74 (95) 3.97 (11) 3.6 7S (765) (295) (47) 3.74 (95) 3.97 (11) 27.9 TM S (864) (31) (554) 3.74 (95) 3.97 (11) 39.6 E = Maximum diameter of pump (149) (348) 27.6 (71) 3.74 (95) 3.97 (11) 38.7 including cable guard and motor. 7S S (111) (31) 27.6 (71) 3.74 (95) 3.97 (11) (111) (31) 27.6 (71) 3.74 (95) 3.97 (11) (1322) (495) (827) 3.74 (95) 3.97 (11) (1175) (348) (827) 3.74 (95) 3.97 (11) (1175) (348) (827) 3.74 (95) 3.97 (11) 48.5 Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO (E) Annex A. Minimum submergence is 2 feet. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 23

24 6 1S (1 gpm) [m] DS (5 hp) -48DS (5 hp) 1S 6 z, SF 1.15 ISO 996 Annex A (3 hp) 8-27 (2 hp) (1.5 hp) (1 hp) -12 (.75 hp) -9 (.5 hp) -6 (.5 hp) Q [US GPM] [kw] Q [m³/h] [hp].1 Eff.8 Eff [%] Q [US GPM] TM

25 6 1S (1 gpm) Pump model Nom. head Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 1S, motor dia. 4 inch, 2 wire motor, 6 z - rated flow 1 gpm (1.25" NPT) Net weight (complete) [lb] 1S (56) 1.99 (279) 11.7 (281) 3.74 (95) 3.97 (11) 2.7 1S (623) 1.99 (279) (344) 3.74 (95) 3.97 (11) (623) 1.99 (279) (344) 3.74 (95) 3.97 (11) S (71) (294) 16.3 (47) 3.74 (95) 3.97 (11) S (779) (39) (47) 3.74 (95) 3.97 (11) S NPT 1S (944) (348) (596) 3.74 (95) 3.97 (11) S, motor dia. 4 inch, 3 wire motor, 6 z - rated flow 1 gpm (1.25" NPT) 1S (629) (348) 11.7 (281) 3.74 (95) 3.97 (11) (623) 1.99 (279) (344) 3.74 (95) 3.97 (11) S (623) 1.99 (279) (344) 3.74 (95) 3.97 (11) S (71) (294) 16.3 (47) 3.74 (95) 3.97 (11) 28.8 TM E = Maximum diameter of pump including cable guard and motor. 1S (779) (39) (47) 3.74 (95) 3.97 (11) (944) (348) (596) 3.74 (95) 3.97 (11) S (95) (39) (596) 3.74 (95) 3.97 (11) (95) (39) (596) 3.74 (95) 3.97 (11) (1217) (495) (722) 3.74 (95) 3.97 (11) S (17) (348) (722) 3.74 (95) 3.97 (11) (17) (348) (722) 3.74 (95) 3.97 (11) (1488) 22.6 (574) (914) 3.74 (95) 3.97 (11) S (1371) 18. (457) (914) 3.74 (95) 3.97 (11) (1371) 18. (457) (914) 3.74 (95) 3.97 (11) (1884) (676) (128) 3.74 (95) 3.97 (11) S5-48DS (1782) 22.6 (574) (128) 3.74 (95) 3.97 (11) (1782) 22.6 (574) (128) 3.74 (95) 3.97 (11) (2272) (676) (1597) 3.74 (95) 4.25 (18) S5-58DS (2171) 22.6 (574) (1597) 3.74 (95) 4.25 (18) (2171) 22.6 (574) (1597) 3.74 (95) 4.25 (18) Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. DS designation = Built into sleeve, 1-1/4" NPT, 6" minimum well diameter. Performance conforms to ISO (E) Annex A. Minimum submergence is 2 feet. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 25

26 6 16S (16 gpm) [m] DS (1 hp) -56DS (7.5 hp) 16S 6 z, SF 1.15 ISO 996 Annex A (5 hp) (3 hp) -18 (2 hp) (1.5 hp) -1 (1 hp) -8 (.75 hp) -5 (.5 hp) Q [US GPM] [kw] Q [m³/h] [hp].24 Eff.16.8 Eff [%] Q [US GPM] TM

27 6 16S (16 gpm) Pump model Nom. head Ph 16S Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 16S, motor dia. 4 inch, 2 wire motor, 6 z - rated flow 16 gpm (1.25" NPT) Net weight (complete) [lb] (54) 11.3 (28) 1.24 (26) 3.74 (95) 3.97 (11) (54) 11.3 (28) 1.24 (26) 3.74 (95) 3.97 (11) S (618) (295) (323) 3.74 (95) 3.97 (11) S (675) (31) (365) 3.74 (95) 3.97 (11) S (797) (348) (449) 3.74 (95) 3.97 (11) S S, motor dia. 4 inch, 3 wire motor, 6 z - rated flow 16 gpm (1.25" NPT) (54) 11.3 (28) 1.24 (26) 3.74 (95) 3.97 (11) (54) 11.3 (28) 1.24 (26) 3.74 (95) 3.97 (11) S (618) (295) (323) 3.74 (95) 3.97 (11) S (675) (31) (365) 3.74 (95) 3.97 (11) S (797) (348) (449) 3.74 (95) 3.97 (11) (759) (31) (449) 3.74 (95) 3.97 (11) (759) (31) (449) 3.74 (95) 3.97 (11) 28.8 B C 16S E D Rp 1 NPT A TM S (128) (495) 2.99 (533) 3.74 (95) 3.97 (11) (881) (348) 2.99 (533) 3.74 (95) 3.97 (11) (881) (348) 2.99 (533) 3.74 (95) 3.97 (11) (1233) 22.6 (574) (659) 3.74 (95) 3.97 (11) 62.1 E = Maximum diameter of pump including cable guard and motor. 16S (1116) 18. (457) (659) 3.74 (95) 3.97 (11) (1116) 18. (457) (659) 3.74 (95) 3.97 (11) (1674) (676) 39.3 (998) 3.74 (95) 3.97 (11) S (1575) (577) 39.3 (998) 3.74 (95) 3.97 (11) (1575) (577) 39.3 (998) 3.74 (95) 3.97 (11) 9. 16S, motor dia. 6 inch, 3 wire motor, 6 z - rated flow 16 gpm (1.25" NPT) 16S75-56DS (2423) (676) (1747) 5.63 (143) 5.51 (14) (2423) (676) (1747) 5.63 (143) 5.51 (14) S1-75DS (2923) 3.6 (777) (2146) 5.63 (143) 5.51 (14) 19. Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. DS designation = Built into sleeve, 1-1/4" NPT, 6" minimum well diameter. Performance conforms to ISO (E) Annex A. Minimum submergence is 2 feet. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 27

28 6 25S (25 gpm) [m] DS (1 hp) -39DS (7.5 hp) 25S 6 z, SF 1.15 ISO 996 Annex A (5 hp) (3 hp) -11 (2 hp) -9 (1.5 hp) -7 (1 hp) -5 (.75 hp) -3 (.5 hp) Q [US GPM] [kw].2.1 [hp] Q [m³/h] Eff Eff [%] Q [US GPM] TM

29 6 25S (25 gpm) Pump model Nom. head Ph 25S Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 25S, motor dia. 4 inch, 2 wire motor, 6 z - rated flow 25 gpm (1.5" NPT) Net weight (complete) [lb] (498) 11.3 (28) 8.59 (218) 3.74 (95) 3.97 (11) (498) 11.3 (28) 8.59 (218) 3.74 (95) 3.97 (11) S (555) (295) 1.24 (26) 3.74 (95) 3.97 (11) S (612) (31) (32) 3.74 (95) 3.97 (11) S (692) (348) (344) 3.74 (95) 3.97 (11) S S, motor dia. 4 inch, 3 wire motor, 6 z - rated flow 25 gpm (1.5" NPT) (498) 11.3 (28) 8.59 (218) 3.74 (95) 3.97 (11) (498) 11.3 (28) 8.59 (218) 3.74 (95) 3.97 (11) S (555) (295) 1.24 (26) 3.74 (95) 3.97 (11) S (612) (31) (32) 3.74 (95) 3.97 (11) S (692) (348) (344) 3.74 (95) 3.97 (11) (654) (31) (344) 3.74 (95) 3.97 (11) (654) (31) (344) 3.74 (95) 3.97 (11) 28.8 B C 25S E D Rp 1 NPT A TM S (881) (495) 15.2 (386) 3.74 (95) 3.97 (11) (734) (348) 15.2 (386) 3.74 (95) 3.97 (11) (734) (348) 15.2 (386) 3.74 (95) 3.97 (11) (144) 22.6 (574) (47) 3.74 (95) 3.97 (11) 61.2 E = Maximum diameter of pump including cable guard and motor. 25S (927) 18. (457) (47) 3.74 (95) 3.97 (11) (927) 18. (457) (47) 3.74 (95) 3.97 (11) (1377) (676) 27.6 (71) 3.74 (95) 3.97 (11) S (1278) (577) 27.6 (71) 3.74 (95) 3.97 (11) (1278) (577) 27.6 (71) 3.74 (95) 3.97 (11) S, motor dia. 6 inch, 3 wire motor, 6 z - rated flow 25 gpm (1.5" NPT) 25S75-39DS (1646) (565) (181) 5.63 (143) 5.43 (138) (1646) (565) (181) 5.63 (143) 5.43 (138) S1-52DS (2253) (59) (1663) 5.63 (143) 5.51 (14) Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. DS designation = Built into sleeve, 1-1/2" NPT, 6" minimum well diameter. Performance conforms to ISO (E) Annex A. Minimum submergence is 2 feet. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 29

30 6 4S (4 gpm) [m] DS (2 hp) -58DS (2 hp) -5DS (2 hp) 4S 6 z, SF 1.15 ISO 996 Annex A DS (15 hp) DS (15 hp) (1 hp) -25 (7.5 hp) -21 (7.5 hp) (5 hp) -12 (5 hp) -9 (3 hp) -7 (2 hp) -5 (1.5 hp) -3 (1 hp) Q [US GPM] [kw] [hp] Q [m³/h] Eff [%].4.6 Eff Q [US GPM] TM

31 6 4S (4 gpm) Pump model Nom. head Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 4S - Motor dia. 4 inch, 2 wire motor, 6 z, rated flow 4 gpm (2" NPT) Net weight (complete) [lb] 4S (635) (31) 12.8 (325) 3.74 (95) 3.97 (11) S (757) (348) (49) 3.74 (95) 3.97 (11) 3.6 4S - Motor dia. 4 inch, 3 wire motor, 6 z, rated flow 4 gpm (2" NPT) 4S (635) (31) 12.8 (325) 3.74 (95) 3.97 (11) S S (757) (348) (49) 3.74 (95) 3.97 (11) (719) (31) (49) 3.74 (95) 3.97 (11) (719) (31) (49) 3.74 (95) 3.97 (11) (988) (495) (493) 3.74 (95) 3.97 (11) (841) (348) (493) 3.74 (95) 3.97 (11) (841) (348) (493) 3.74 (95) 3.97 (11) (1151) 22.6 (574) (577) 3.74 (95) 3.97 (11) 74.1 B C 4S E D NPT A TM S S (134) 18. (457) (577) 3.74 (95) 3.97 (11) (134) 18. (457) (577) 3.74 (95) 3.97 (11) (1379) (676) (73) 3.74 (95) 3.97 (11) (128) (577) (73) 3.74 (95) 3.97 (11) (128) (577) (73) 3.74 (95) 3.97 (11) (155) (676) (829) 3.74 (95) 3.97 (11) 8.1 E = Maximum diameter of pump including cable guard and motor. 4S (146) (577) (829) 3.74 (95) 3.97 (11) (146) (577) (829) 3.74 (95) 3.97 (11) 8.1 4S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 4 gpm (2" NPT) 4S S (1758) (677) (181) 3.74 (95) 3.97 (11) (1758) (677) (181) 3.74 (95) 3.97 (11) (1926) (677) (1249) 3.74 (95) 3.97 (11) (1926) (677) (1249) 3.74 (95) 3.97 (11) S (2236) 3.6 (777) (1459) 3.74 (95) 3.97 (11) S15-37DS S15-44DS S2-5DS S2-58DS S2-66DS (2523) (78) (1815) 5.63 (143) 5.43 (138) (2523) (78) (1815) 5.63 (143) 5.43 (138) (2817) (78) 83.4 (219) 5.63 (143) 5.43 (138) (2817) (78) 83.4 (219) 5.63 (143) 5.43 (138) (346) 3.83 (783) 15.4 (2677) 5.63 (143) 5.51 (14) (346) 3.83 (783) 15.4 (2677) 5.63 (143) 5.51 (14) (3796) 3.83 (783) (313) 5.63 (143) 5.51 (14) (3796) 3.83 (783) (313) 5.63 (143) 5.51 (14) (4132) 3.83 (783) (3349) 5.63 (143) 5.51 (14) (4132) 3.83 (783) (3349) 5.63 (143) 5.51 (14) Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. DS designation = Built into sleeve, 2" NPT, 6" minimum well diameter. Performance conforms to ISO (E) Annex A. Minimum submergence is 5 feet. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. 31

32 6 6S (6 gpm) [m] (1 hp) 6S 6 z, SF 1.15 ISO 996 Annex A -13 (7.5 hp) (5 hp) (5 hp) (3 hp) -4 (2 hp) Q [US GPM] [kw].8 [hp] Q [m³/h] Eff Eff [%] Q [US GPM] TM

33 6 6S (6 gpm) Pump model Nom. head 6S S S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 6S - Motor dia. 4 inch, 3 wire motor, 6 z, rated flow 6 gpm (2" NPT) Net weight (complete) [lb] (94) (495) (445) 3.74 (95) 3.97 (11) (793) (348) (445) 3.74 (95) 3.97 (11) (793) (348) (445) 3.74 (95) 3.97 (11) (184) 22.6 (574) 2.8 (51) 3.74 (95) 3.97 (11) (967) 18. (457) 2.8 (51) 3.74 (95) 3.97 (11) (967) 18. (457) 2.8 (51) 3.74 (95) 3.97 (11) (1316) (676) 25.2 (64) 3.74 (95) 3.97 (11) (1217) (577) 25.2 (64) 3.74 (95) 3.97 (11) (1217) (577) 25.2 (64) 3.74 (95) 3.97 (11) (1446) (676) 3.32 (77) 3.74 (95) 3.97 (11) 85.5 B C 6S E D NPT A TM S S (1347) (577) 3.32 (77) 3.74 (95) 3.97 (11) (1347) (577) 3.32 (77) 3.74 (95) 3.97 (11) (177) (677) 4.56 (13) 3.74 (95) 3.97 (11) (177) (677) 4.56 (13) 3.74 (95) 3.97 (11) E = Maximum diameter of pump including cable guard and motor. 6S (2132) 3.6 (777) (1355) 3.74 (95) 3.97 (11) S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 6 gpm (2" NPT) 6S S (1657) (565) 43. (192) 5.63 (143) 5.43 (138) (1657) (565) 43. (192) 5.63 (143) 5.43 (138) (27) (59) (1417) 5.63 (143) 5.43 (138) (27) (59) (1417) 5.63 (143) 5.43 (138) 27. Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box.diameter. Performance conforms to ISO (E) Annex A. Minimum submergence is 5 feet. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 33

34 6 75S (75 gpm) [m] (1 hp) -15 (1 hp) -12 (7.5 hp) 75S 6 z, SF 1.15 ISO 996 Annex A (7.5 hp) (5 hp) (3 hp) 1-3 (2 hp) Q [US GPM] [kw].8 [hp] Q [m³/h] Eff Eff [%] Q [US GPM] TM

35 6 75S (75 gpm) Pump model Nom. head 75S S S Ph 75S Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 75S - Motor dia. 4 inch, 3 wire motor, 6 z, rated flow 75 gpm (2" NPT) Net weight (complete ) [lb] (875) (495) (38) 3.74 (95) 3.97 (11) (728) (348) (38) 3.74 (95) 3.97 (11) (728) (348) (38) 3.74 (95) 3.97 (11) (184) 22.6 (574) 2.8 (51) 3.74 (95) 3.97 (11) (967) 18. (457) 2.8 (51) 3.74 (95) 3.97 (11) (967) 18. (457) 2.8 (51) 3.74 (95) 3.97 (11) (1381) (676) (75) 3.74 (95) 3.97 (11) (1282) (577) (75) 3.74 (95) 3.97 (11) (1282) (577) (75) 3.74 (95) 3.97 (11) (1642) (677) 38. (965) 3.74 (95) 3.97 (11) (1642) (677) 38. (965) 3.74 (95) 3.97 (11) S (22) 3.6 (777) (1225) 3.74 (95) 3.97 (11) S S S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 75 gpm (2" NPT) (1527) (565) (962) 5.63 (143) 5.43 (138) (1527) (565) (962) 5.63 (143) 5.43 (138) (1782) (59) (1192) 5.63 (143) 5.43 (138) (1782) (59) (1192) 5.63 (143) 5.43 (138) B C 75S E D NPT A TM E = Maximum diameter of pump including cable guard and motor. Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO (E) Annex A. Minimum submergence is 5 feet. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 35

36 6 85S (85 gpm) [m] (2 hp) -17 (2 hp) -16 (2 hp) -15 (2 hp) -14 (2 hp) 85S 6 z, SF 1.15 ISO 996 Annex A 7-13 (15 hp) 2-12 (15 hp) 6-11 (15 hp) -1 (15 hp) (1 hp) 4-8 (1 hp) -7 (1 hp) (7.5 hp) -5 (7.5 hp) (5 hp) -3 (5 hp) -2 (3 hp) -1 (1.5 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

37 6 85S (85 gpm) [m] (5 hp) -36 (4 hp) 85S 6 z, SF 1.15 ISO 996 Annex A (4 hp) (4 hp) -29 (4 hp) -28 (4 hp) -27 (3 hp) -26 (3 hp) -25 (3 hp) -24 (3 hp) -23 (3 hp) -22 (25 hp) -21 (25 hp) -2 (25 hp) -19 (25 hp) Q [US GPM] [m] Q [m³/h] Eff [%] 12 4 Eff NPS Q [US GPM] TM

38 6 85S (85 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -18 (2 hp) -17 (2 hp) -16 (2 hp) (2 hp) -14 (2 hp) (15 hp) -12 (15 hp) (15 hp) -1 (15 hp) (1 hp) -8 (1 hp) -7 (1 hp) (7.5 hp) (7.5 hp) -4 (5 hp) 4-3 (5 hp) (3 hp) -1 (1.5 hp) Q [US GPM] Q [m³/h] TM

39 6 85S (85 gpm) pump power requirement () [kw] 4 36 [hp] S 6 z, SF 1.15 ISO 996 Annex A -39 (5 hp) -36 (4 hp) (4 hp) (4 hp) -29 (4 hp) -28 (4 hp) -27 (3 hp) (3 hp) -25 (3 hp) -24 (3 hp) -23 (3 hp) -22 (25 hp) -21 (25 hp) -2 (25 hp) -19 (25 hp) Q [US GPM] Q [m³/h] TM

40 6 85S (85 gpm) Pump model Nom. head 85S S S S S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 85S - Motor dia. 4 inch, 3 wire motor, 6 z, rated flow 85 gpm (3" NPT) Net weight (complete) [lb] (71) (387) (314) 3.74 (95) 5.16 (131) (661) (347) (314) 3.74 (95) 5.16 (131) (661) (347) (314) 3.74 (95) 5.16 (131) (951) (577) (374) 3.74 (95) 5.16 (131) (83) (456) (374) 3.74 (95) 5.16 (131) (83) (456) (374) 3.74 (95) 5.16 (131) (1112) (677) (435) 3.74 (95) 5.16 (131) (111) (576) (435) 3.74 (95) 5.16 (131) (111) (576) (435) 3.74 (95) 5.16 (131) (1112) (677) (435) 3.74 (95) 5.16 (131) (111) (576) (435) 3.74 (95) 5.16 (131) (111) (576) (435) 3.74 (95) 5.16 (131) (1232) (676) (556) 3.74 (95) 5.16 (131) (1232) (676) (556) 3.74 (95) 5.16 (131) 73.8 B C 85S E D NPT A TM S (1292) (676) (616) 3.74 (95) 5.16 (131) 85.5 E = Maximum diameter of pump (1292) (676) (616) 3.74 (95) 5.16 (131) 76.5 including cable guard and motor. 85S (1453) 3.56 (776) (677) 3.74 (95) 5.16 (131) S (1513) 3.56 (776) 29.2 (737) 3.74 (95) 5.16 (131) S (1574) 3.56 (776) (798) 3.74 (95) 5.16 (131) S S S S S S S S S S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 85 gpm (3" NPT) (1137) (565) (572) 5.63 (143) 5.59 (142) (1137) (565) (572) 5.63 (143) 5.59 (142) (1197) (565) (632) 5.63 (143) 5.59 (142) (1197) (565) (632) 5.63 (143) 5.59 (142) (1283) (59) (693) 5.63 (143) 5.59 (142) (1283) (59) (693) 5.63 (143) 5.59 (142) (1343) (59) (753) 5.63 (143) 5.59 (142) (1343) (59) (753) 5.63 (143) 5.59 (142) (144) (59) 32.5 (814) 5.63 (143) 5.6 (142) (144) (59) 32.5 (814) 5.63 (143) 5.6 (142) (1582) (78) (874) 5.63 (143) 5.6 (142) (1582) (78) (874) 5.63 (143) 5.6 (142) (1643) (78) (935) 5.63 (143) 5.6 (142) (1643) (78) (935) 5.63 (143) 5.6 (142) (173) (78) (995) 5.63 (143) 5.6 (142) (173) (78) (995) 5.63 (143) 5.6 (142) (1764) (78) (156) 5.63 (143) 5.6 (142) (1764) (78) (156) 5.63 (143) 5.6 (142) 135. Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 5 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 4

41 6 85S (85 gpm) Pump model Nom. head 85S S S S S S S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 85S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 85 gpm (3" NPT) Net weight (complete) [lb] (1899) 3.83 (783) (1116) 5.63 (143) 5.6 (142) (1899) 3.83 (783) (1116) 5.63 (143) 5.6 (142) (196) 3.83 (783) (1177) 5.63 (143) 5.6 (142) (196) 3.83 (783) (1177) 5.63 (143) 5.6 (142) (22) 3.83 (783) (1237) 5.63 (143) 5.6 (142) (22) 3.83 (783) (1237) 5.63 (143) 5.6 (142) (281) 3.83 (783) (1298) 5.63 (143) 5.6 (142) (281) 3.83 (783) (1298) 5.63 (143) 5.6 (142) (2141) 3.83 (783) (1358) 5.63 (143) 5.6 (142) (2141) 3.83 (783) (1358) 5.63 (143) 5.6 (142) (2257) 33. (838) (1419) 5.63 (143) 5.6 (142) (2257) 33. (838) (1419) 5.63 (143) 5.6 (142) (2333) 33. (838) (1495) 5.63 (143) 5.6 (142) (2333) 33. (838) (1495) 5.63 (143) 5.6 (142) B C 85S E D NPT A TM S (2394) 33. (838) (1556) 5.63 (143) 5.6 (142) 198. E = Maximum diameter of pump (2394) 33. (838) (1556) 5.63 (143) 5.6 (142) 198. including cable guard and motor (2454) 33. (838) (1616) 5.63 (143) 5.6 (142) S (2454) 33. (838) (1616) 5.63 (143) 5.6 (142) (2579) (93) (1676) 5.63 (143) 5.6 (142) S (2579) (93) (1676) 5.63 (143) 5.6 (142) (264) (93) (1737) 5.63 (143) 5.6 (142) S (264) (93) (1737) 5.63 (143) 5.6 (142) (271) (93) 7.79 (1798) 5.63 (143) 5.6 (142) S (271) (93) 7.79 (1798) 5.63 (143) 5.6 (142) (2761) (93) (1858) 5.63 (143) 5.6 (142) S (2761) (93) (1858) 5.63 (143) 5.6 (142) (2822) (93) (1919) 5.63 (143) 5.6 (142) S (2822) (93) (1919) 5.63 (143) 5.6 (142) S (32) 4.28 (123) (1979) 5.63 (143) 5.6 (142) S (363) 4.28 (123) 8.32 (24) 5.63 (143) 5.6 (142) S (3123) 4.28 (123) (21) 5.63 (143) 5.6 (142) S4-33DS (3536) 4.28 (123) (2513) 5.63 (143) 6.9 (176) S4-36DS (3717) 4.28 (123) 16.7 (2694) 5.63 (143) 6.9 (176) S5-39DS (4299) 56.3 (1423) (2876) 5.63 (143) 6.9 (176) S - Motor dia. 8 inch, 3 wire motor, 6 z, rated flow 85 gpm (3" NPT) 85S4-33DS (3578) (111) (2468) 7.56 (192) 7.56 (192) S4-36DS (3758) (111) (2648) 7.56 (192) 7.56 (192) S4-39DS (3938) (111) (2828) 7.56 (192) 7.56 (192) Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. DS designation = Built into sleeve, 3" NPT, 8" minimum well diameter. Performance conforms to ISO 996 Annex 5 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 41

42 6 15S (15 gpm) [m] (3 hp) -16 (3 hp) -15 (3 hp) -14 (25 hp) -13 (25 hp) -12 (25 hp) 15S 6 z, SF 1.15 ISO 996 Annex A (2 hp) -1 (2 hp) -9 (2 hp) -8 (15 hp) (15 hp) (15 hp) -5 (1 hp) -4 (7.5 hp) -3 (7.5 hp) -2 (5 hp) -1 (2 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

43 6 15S (15 gpm) [m] (75 hp) -36 (75 hp) -33 (6 hp) -31 (6 hp) 15S 6 z, SF 1.15 ISO 996 Annex A (6 hp) -28 (5 hp) -27 (5 hp) -26 (5 hp) -25 (5 hp) -24 (5 hp) -23 (4 hp) -22 (4 hp) -21 (4 hp) -2 (4 hp) -19 (4 hp) -18 (4 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

44 6 15S (15 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -17 (3 hp) -16 (3 hp) -15 (3 hp) (25 hp) -13 (25 hp) -12 (25 hp) (2 hp) (2 hp) -9 (2 hp) (15 hp) (15 hp) -6 (15 hp) -5 (1 hp) (7.5 hp) (7.5 hp) -2 (5 hp) -1 (2 hp) Q [US GPM] Q [m³/h] TM

45 6 15S (15 gpm) pump power requirement () [kw] 6 55 [hp] S 6 z, SF 1.15 ISO 996 Annex A -39 (75 hp) -36 (75 hp) (6 hp) (6 hp) (6 hp) (5 hp) -27 (5 hp) -26 (5 hp) -25 (5 hp) -24 (5 hp) -23 (4 hp) -22 (4 hp) -21 (4 hp) -2 (4 hp) -19 (4 hp) -18 (4 hp) Q [US GPM] Q [m³/h] TM

46 6 15S (15 gpm) Pump model Nom. head 15S S S S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 15S - Motor dia. 4 inch, 3 wire motor, 6 z, rated flow 15 gpm (3" NPT) Net weight (complete) [lb] (846) (497) (349) 3.75 (95) 5.16 (131) (736) (387) (349) 3.75 (95) 5.16 (131) (736) (387) (349) 3.75 (95) 5.16 (131) (1122) (677) (445) 3.75 (95) 5.16 (131) (121) (576) (445) 3.75 (95) 5.16 (131) (121) (576) (445) 3.75 (95) 5.16 (131) (1217) (676) 21.3 (541) 3.75 (95) 5.16 (131) (1217) (676) 21.3 (541) 3.75 (95) 5.16 (131) (1313) (676) 25.8 (637) 3.75 (95) 5.16 (131) (1313) (676) 25.8 (637) 3.75 (95) 5.16 (131) S (159) 3.56 (776) (733) 3.75 (95) 5.16 (131) S S S S S S S S S S S S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 15 gpm (3" NPT) (1218) (565) (653) 5.63 (143) 5.6 (142) (1218) (565) (653) 5.63 (143) 5.6 (142) 99.9 E = Maximum diameter of pump (1339) (59) (749) 5.63 (143) 5.6 (142) 73.8 including cable guard and motor (1339) (59) (749) 5.63 (143) 5.6 (142) (1553) (78) (845) 5.63 (143) 5.6 (142) (1553) (78) (845) 5.63 (143) 5.6 (142) (1649) (78) 37.5 (941) 5.63 (143) 5.6 (142) (1649) (78) 37.5 (941) 5.63 (143) 5.6 (142) (1745) (78) 4.83 (137) 5.63 (143) 5.6 (142) (1745) (78) 4.83 (137) 5.63 (143) 5.6 (142) (1916) 3.83 (783) (1133) 5.63 (143) 5.6 (142) (1916) 3.83 (783) (1133) 5.63 (143) 5.6 (142) (212) 3.83 (783) (1229) 5.63 (143) 5.6 (142) (212) 3.83 (783) (1229) 5.63 (143) 5.6 (142) (218) 3.83 (783) (1325) 5.63 (143) 5.6 (142) (218) 3.83 (783) (1325) 5.63 (143) 5.6 (142) (2257) (836) (1421) 5.63 (143) 5.6 (142) (2257) (836) (1421) 5.63 (143) 5.6 (142) (2353) (836) (1517) 5.63 (143) 5.6 (142) (2353) (836) (1517) 5.63 (143) 5.6 (142) (2449) (836) (1613) 5.63 (143) 5.6 (142) (2449) (836) (1613) 5.63 (143) 5.6 (142) 26.1 B C 15S E D NPT A TM Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 5 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 46

47 6 15S (15 gpm) Pump model Nom. head 15S S S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 15S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 15 gpm (3" NPT) Net weight (complete) [lb] (2612) (93) (179) 5.63 (143) 5.6 (142) (2612) (93) (179) 5.63 (143) 5.6 (142) (278) (93) 71.7 (185) 5.63 (143) 5.6 (142) (278) (93) 71.7 (185) 5.63 (143) 5.6 (142) (284) (93) (191) 5.63 (143) 5.6 (142) (284) (93) (191) 5.63 (143) 5.6 (142) S (32) 4.28 (123) (1997) 5.63 (143) 5.6 (142) S (3116) 4.28 (123) (293) 5.63 (143) 5.6 (142) S (3212) 4.28 (123) (2189) 5.63 (143) 5.6 (142) S (338) 4.28 (123) (2285) 5.63 (143) 5.67 (144) S (344) 4.28 (123) (2381) 5.63 (143) 5.67 (144) S (35) 4.28 (123) (2477) 5.63 (143) 5.67 (144) S (3998) (1425) 11.3 (2573) 5.67 (144) 5.6 (142) B C 15S E D NPT A TM S (494) (1425) 15.8 (2669) 5.67 (144) 5.6 (142) S (419) (1425) (2765) 5.67 (144) 5.6 (142) E = Maximum diameter of pump 15S (4286) (1425) (2861) 5.67 (144) 5.6 (142) including cable guard and motor. 15S (4382) (1425) (2957) 5.67 (144) 5.6 (142) S6-29DS (3278) 7.1 (181) 15S6-31DS (347) 7.1 (181) 15S6-33DS (3662) 7.1 (181) 15S - Motor dia. 8 inch, 3 wire motor, 6 z, rated flow 15 gpm (3" NPT) 15S * (3762) (116) (262) 7.56 (192) 7.56 (192) S * (3858) (116) (2698) 7.56 (192) 7.56 (192) S * (3954) (116) 11. (2794) 7.56 (192) 7.56 (192) S * (45) (116) (289) 7.56 (192) 7.56 (192) S * (4146) (116) (2986) 7.56 (192) 7.56 (192) S6-29DS * (4519) 5. (127) (3249) 7.56 (192) 7.56 (192) S6-31DS * (4711) 5. (127) (3441) 7.56 (192) 7.56 (192) S6-33DS * (493) 5. (127) (3633) 7.56 (192) 7.56 (192) S75-36DS * (5271) (135) (3921) 7.56 (192) 7.56 (192) S75-39DS * (5559) (135) (429) 7.56 (192) 7.56 (192) 74.6 Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. DS designation = Built into sleeve, 3" NPT, 8" minimum well diameter. Performance conforms to ISO 996 Annex 5 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 47

48 6 23S (23 gpm) [m] (25 hp) -7 (25 hp) -7-C (2 hp) -6 (2 hp) 23S 6 z, SF 1.15 ISO 996 Annex A (2 hp) 3-5-B (15 hp) (15 hp) BC (1 hp) -3 (1 hp) BB (7.5 hp) -2 (7.5 hp) -2-AB (5 hp) (5 hp) -1-A (3 hp) -1-B (2 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

49 6 23S (23 gpm) [m] (75 hp) -2 (75 hp) -19 (6 hp) -18 (6 hp) -17 (6 hp) 23S 6 z, SF 1.15 ISO 996 Annex A (5 hp) -15 (5 hp) (5 hp) -13 (4 hp) -12 (4 hp) (4 hp) -1 (3 hp) -9 (3 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

50 6 23S (23 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -8 (25 hp) -7 (25 hp) C (2 hp) (2 hp) (2 hp) -5-B (15 hp) -4 (15 hp) -4-BC (1 hp) -3 (1 hp) BB (7.5 hp) (7.5 hp) -2-AB (5 hp) -1 (5 hp) -1-A (3 hp) -1-B (2 hp) Q [US GPM] Q [m³/h] TM

51 6 23S (23 gpm) pump power requirement () [kw] 6 55 [hp] S 6 z, SF 1.15 ISO 996 Annex A -22 (75 hp) (75 hp) -19 (6 hp) -18 (6 hp) (6 hp) -16 (5 hp) -15 (5 hp) -14 (5 hp) (4 hp) -12 (4 hp) (4 hp) -1 (3 hp) -9 (3 hp) -9-BB (25 hp) Q [US GPM] Q [m³/h] TM

52 6 23S (23 gpm) Pump model Nom. head 23S2-1B 24 23S3-1A 3 23S S5-2AB 56 23S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 23S - Motor dia. 4 inch, 3 wire motor, 6 z, rated flow 23 gpm (3" NPT) Net weight (complete) [lb] (861) (497) (364) 3.75 (95) 5.75 (146) (751) (387) (364) 3.75 (95) 5.75 (146) (751) (387) (364) 3.75 (95) 5.75 (146) (941) (577) (364) 3.75 (95) 5.75 (146) (1185) (456) (364) 3.75 (95) 5.75 (146) (1185) (456) (364) 3.75 (95) 5.75 (146) (141) (677) (364) 3.75 (95) 5.75 (146) (94) (576) (364) 3.75 (95) 5.75 (146) (94) (576) (364) 3.75 (95) 5.75 (146) (1154) (677) (477) 3.75 (95) 5.75 (146) (153) (576) (477) 3.75 (95) 5.75 (146) (153) (576) (477) 3.75 (95) 5.75 (146) (1153) (676) (59) 3.75 (95) 5.75 (146) (1153) (676) (59) 3.75 (95) 5.75 (146) 79.2 B C 23S E D NPT A TM S75-3BB (1266) (676) (59) 3.75 (95) 5.75 (146) 126. E = Maximum diameter of pump (1266) (676) (59) 3.75 (95) 5.75 (146) 126. including cable guard and motor. 23S (1366) 3.56 (776) (59) 3.75 (95) 5.75 (146) S1-4BC (1366) 3.56 (776) (59) 3.75 (95) 5.75 (146) S S75-3BB 9 23S S1-4BC S S15-5B S S S2-7C S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 23 gpm (3" NPT) (158) (565) (493) 5.63 (143) 5.99 (152) (158) (565) (493) 5.63 (143) 5.99 (152) (1171) (565) (66) 5.63 (143) 5.99 (152) (1171) (565) (66) 5.63 (143) 5.99 (152) (1196) (59) (66) 5.63 (143) 5.99 (152) (1196) (59) (66) 5.63 (143) 5.99 (152) (139) (59) (719) 5.63 (143) 5.99 (152) (139) (59) (719) 5.63 (143) 5.99 (152) (1427) (78) (719) 5.63 (143) 5.99 (152) (1427) (78) (719) 5.63 (143) 5.99 (152) (154) (78) (832) 5.63 (143) 5.99 (152) (154) (78) (832) 5.63 (143) 5.99 (152) (1615) 3.83 (783) (832) 5.63 (143) 5.99 (152) (1615) 3.83 (783) (832) 5.63 (143) 5.99 (152) (1728) 3.83 (783) (945) 5.63 (143) 5.99 (152) (1728) 3.83 (783) (945) 5.63 (143) 5.99 (152) (1841) 3.83 (783) (158) 5.63 (143) 5.99 (152) (1841) 3.83 (783) (158) 5.63 (143) 5.99 (152) Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 8 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 52

53 6 23S (23 gpm) Pump model Nom. head 23S S25-8B S S25-9BB S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 23S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 23 gpm (3" NPT) Net weight (complete) [lb] (1896) 33. (838) (158) 5.63 (143) 5.99 (152) (1896) 33. (838) (158) 5.63 (143) 5.99 (152) (29) 33. (838) (1171) 5.63 (143) 5.99 (152) (29) 33. (838) (1171) 5.63 (143) 5.99 (152) (29) 33. (838) (1171) 5.63 (143) 5.99 (152) (29) 33. (838) (1171) 5.63 (143) 5.99 (152) (2122) 33. (838) 5.56 (1284) 5.63 (143) 5.99 (152) (2122) 33. (838) 5.56 (1284) 5.63 (143) 5.99 (152) (2187) (93) 5.56 (1284) 5.63 (143) 5.99 (152) (2187) (93) 5.56 (1284) 5.63 (143) 5.99 (152) S (242) 4.28 (123) 55. (1397) 5.63 (143) 5.99 (152) S (2533) 4.28 (123) (151) 5.63 (143) 5.99 (152) S (2646) 4.28 (123) 63.9 (1623) 5.63 (143) 5.99 (152) B C 23S E D NPT A TM S (2759) 4.28 (123) (1736) 5.63 (143) 5.99 (152) S (3357) (1425) 76.7 (1932) 5.67 (144) 5.99 (152) 356. E = Maximum diameter of pump 23S (347) (1425) 8.52 (245) 5.67 (144) 5.99 (152) 36.5 including cable guard and motor. 23S (3583) (1425) (2158) 5.67 (144) 5.99 (152) S (2249) 5.99 (152) 23S (2362) 5.99 (152) 23S (2475) 7.56 (192) 23S - Motor dia. 8 inch, 3 wire motor, 6 z, rated flow 23 gpm (3" NPT) 23S (349) 5. (127) (222) 7.56 (192) 7.56 (192) S (369) 5. (127) (2333) 7.56 (192) 7.56 (192) S (3716) 5. (127) 96.3 (2446) 7.56 (192) 7.56 (192) S75-2DS (399) (135) 1.75 (2559) 7.56 (192) 7.56 (192) S75-22DS (4298) (135) (2948) 7.56 (192) 7.56 (192) 62.4 Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. DS designation = Built into sleeve, 4" NPT, 1" minimum well diameter. Performance conforms to ISO 996 Annex 8 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 53

54 6 3S (3 gpm) [m] (25 hp) -6 (25 hp) -6-B (2 hp) 3S 6 z, SF 1.15 ISO 996 Annex A (2 hp) -5-AA (2 hp) (15 hp) -4-AA (15 hp) (15 hp) -3-A (1 hp) (7.5 hp) 1-2-BB (5 hp) (5 hp) -1-B (3 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

55 6 3S (3 gpm) [m] (75 hp) -17 (75 hp) -16 (75 hp) -15 (6 hp) 3S 6 z, SF 1.15 ISO 996 Annex A (6 hp) 9-13 (5 hp) (5 hp) -11 (5 hp) (4 hp) -9 (4 hp) -9-B (3 hp) -8 (3 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

56 6 3S (3 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -7 (25 hp) -6 (25 hp) B (2 hp) (2 hp) AA (2 hp) -4 (15 hp) AA (15 hp) (15 hp) -3-A (1 hp) (7.5 hp) BB (5 hp) -1 (5 hp) -1-B (3 hp) Q [US GPM] Q [m³/h] TM

57 6 3S (3 gpm) pump power requirement () [kw] 6 55 [hp] S 6 z, SF 1.15 ISO 996 Annex A -18 (75 hp) (75 hp) (75 hp) -15 (6 hp) (6 hp) (5 hp) -12 (5 hp) (5 hp) -1 (4 hp) (4 hp) 3-9-B (3 hp) -8 (3 hp) Q [US GPM] Q [m³/h] TM

58 6 3S (3 gpm) Pump model Nom. head 3S3-1B 19 3S S5-2BB 42 3S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 3S - Motor dia. 4 inch, 3 wire motor, 6 z, rated flow 3 gpm (3" NPT) Net weight (complete) [lb] (944) (577) (367) 3.75 (95) 5.83 (148) (823) (456) (367) 3.75 (95) 5.83 (148) (823) (456) (367) 3.75 (95) 5.83 (148) (144) (677) (367) 3.75 (95) 5.83 (148) (943) (576) (367) 3.75 (95) 5.83 (148) (943) (576) (367) 3.75 (95) 5.83 (148) (1157) (677) 18.9 (48) 3.75 (95) 5.83 (148) (156) (576) 18.9 (48) 3.75 (95) 5.83 (148) (156) (576) 18.9 (48) 3.75 (95) 5.83 (148) (1156) (676) 18.9 (48) 3.75 (95) 5.83 (148) (1156) (676) 18.9 (48) 3.75 (95) 5.83 (148) S1-3A (1369) 3.56 (776) (593) 3.75 (95) 5.83 (148) S S1-3A 97 3S S15-4AA 123 3S S2-5AA 17 3S S2-6B 211 3S S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 3 gpm (3" NPT) (161) (565) (496) 5.63 (143) 6.15 (156) E = Maximum diameter of pump (161) (565) (496) 5.63 (143) 6.15 (156) including cable guard and motor (1199) (59) (69) 5.63 (143) 6.15 (156) (1199) (59) (69) 5.63 (143) 6.15 (156) (1317) (78) (69) 5.63 (143) 6.15 (156) (1317) (78) (69) 5.63 (143) 6.15 (156) (143) (78) (722) 5.63 (143) 6.15 (156) (143) (78) (722) 5.63 (143) 6.15 (156) (143) (78) (722) 5.63 (143) 6.15 (156) (143) (78) (722) 5.63 (143) 6.15 (156) (1618) 3.83 (783) (835) 5.63 (143) 6.15 (156) (1618) 3.83 (783) (835) 5.63 (143) 6.15 (156) (1618) 3.83 (783) (835) 5.63 (143) 6.15 (156) (1618) 3.83 (783) (835) 5.63 (143) 6.15 (156) (1731) 3.83 (783) (948) 5.63 (143) 6.15 (156) (1731) 3.83 (783) (948) 5.63 (143) 6.15 (156) (1786) 33. (838) (948) 5.63 (143) 6.15 (156) (1786) 33. (838) (948) 5.63 (143) 6.15 (156) 198. B C 3S E D NPT A TM Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 8 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 58

59 6 3S (3 gpm) Pump model Nom. head 3S25-7AA 249 3S S S3-9B 329 Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 3S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 3 gpm (4" NPT) Net weight (complete) [lb] (1899) 33. (838) (161) 5.63 (143) 6.15 (156) (1899) 33. (838) (161) 5.63 (143) 6.15 (156) (1964) (93) (161) 5.63 (143) 6.15 (156) (1964) (93) (161) 5.63 (143) 6.15 (156) (277) (93) (1174) 5.63 (143) 6.15 (156) (277) (93) (1174) 5.63 (143) 6.15 (156) (219) (93) 5.67 (1287) 5.63 (143) 6.15 (156) (219) (93) 5.67 (1287) 5.63 (143) 6.15 (156) S (231) 4.28 (123) 5.67 (1287) 5.63 (143) 6.15 (156) S (2423) 4.28 (123) (14) 5.63 (143) 6.15 (156) 3.5 3S (2938) (1425) (1513) 5.67 (144) 6.15 (156) S (351) (1425) 64.2 (1626) 5.67 (144) 6.15 (156) S (3164) (1425) (1739) 5.67 (144) 6.15 (156) S (1881) 6.15 (156) B C 3S E D NPT A TM S (1881) 6.15 (156) 3S - Motor dia. 8 inch, 3 wire motor, 6 z, rated flow 23 gpm (4" NPT) 3S * (3151) 5. (127) 74.6 (1881) 7.56 (192) 7.56 (192) S * (3264) 5. (127) (1994) 7.56 (192) 7.56 (192) S * (3457) (135) (217) 7.56 (192) 7.56 (192) S * (357) (135) (222) 7.56 (192) 7.56 (192) S * 145. (3683) (135) (2333) 7.56 (192) 7.56 (192) E = Maximum diameter of pump including cable guard and motor. Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 8 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 59

60 6 385S (385 gpm) [m] B (4 hp) -5 (4 hp) 385S 6 z, SF 1.15 ISO 996 Annex A BB (3 hp) -4 (3 hp) B (25 hp) 3-3 (25 hp) A (2 hp) (18 hp) BA (1 hp) -1 (7.5 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

61 6 385S (385 gpm) [m] (1 hp) -12 (1 hp) -11 (1 hp) 385S 6 z, SF 1.15 ISO 996 Annex A (75 hp) 9-9 (75 hp) (6 hp) (6 hp) 6-6 (5 hp) Q [US GPM] [m] Q [m³/h] Eta Eff [%] NPS Q [US GPM] TM

62 6 385S (385 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -6-B (4 hp) -5 (4 hp) BB (3 hp) -4 (3 hp) B (25 hp) -3 (25 hp) -3-A (2 hp) -2 (18 hp) -2-BA (1 hp) -1 (7.5 hp) Q [US GPM] Q [m³/h] TM

63 6 385S (385 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -13 (1 hp) (1 hp) -11 (1 hp) (75 hp) (75 hp) -8 (6 hp) (6 hp) -6 (5 hp) Q [US GPM] Q [m³/h] TM

64 6 385S (385 gpm) Pump model Nom. head 385S S1-2BA S S2-3A S S25-4B S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 385S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 385 gpm (4" NPT) Net weight (complete) [lb] (1183) (565) (618) 5.63 (143) 7.1 (178) (1183) (565) (618) 5.63 (143) 7.1 (178) (1336) (59) (746) 5.63 (143) 7.1 (178) (1336) (59) (746) 5.63 (143) 7.1 (178) (1454) (78) (746) 5.63 (143) 7.1 (178) (1454) (78) (746) 5.63 (143) 7.1 (178) (1657) 3.83 (783) (874) 5.63 (143) 7.1 (178) (1657) 3.83 (783) (874) 5.63 (143) 7.1 (178) (1712) 33. (838) (874) 5.63 (143) 7.1 (178) (1712) 33. (838) (874) 5.63 (143) 7.1 (178) (184) 33. (838) (12) 5.63 (143) 7.1 (178) (184) 33. (838) (12) 5.63 (143) 7.1 (178) (195) (93) (12) 5.63 (143) 7.1 (178) (195) (93) (12) 5.63 (143) 7.1 (178) NPT B C E D 385S A 4.8 TM S3-5BB (233) (93) (113) 5.63 (143) 7.1 (178) E = Maximum diameter of pump (233) (93) (113) 5.63 (143) 7.1 (178) including cable guard and motor. 385S (2153) 4.28 (123) (113) 5.63 (143) 7.1 (178) S4-6B (2281) 4.28 (123) (1258) 5.63 (143) 7.1 (178) S (2825) (1425) (1394) 5.67 (144) 7.88 (2) 385S5-7A (2825) (1425) (1394) 5.67 (144) 7.88 (2) 385S (14) 7.88 (2) 385S (14) 7.88 (2) 385S - Motor dia. 8 inch, 3 wire motor, 6 z, rated flow 385 gpm (4" NPT) 385S4-6B * (2382) (111) 5.8 (1272) 7.56 (192) 7.88 (2) S * (2432) (116) 5.8 (1272) 7.56 (192) 7.88 (2) S5-7A * 1.79 (256) (116) (14) 7.56 (192) 7.88 (2) S * (267) 5. (127) (14) 7.56 (192) 7.88 (2) S * (2798) 5. (127) 6.16 (1528) 7.56 (192) 7.88 (2) S * (36) (135) 65.2 (1656) 7.56 (192) 7.88 (2) S * (3134) (135) 7.24 (1784) 7.56 (192) 7.88 (2) S * (352) 62.6 (159) (1912) 7.56 (192) 7.88 (2) S * (363) 62.6 (159) 8.32 (24) 7.56 (192) 7.88 (2) S * (3758) 62.6 (159) (2168) 7.56 (192) 7.88 (2) Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 8 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 64

65 6 475S (475 gpm) [m] B (4 hp) -4 (4 hp) 475S 6 z, SF 1.15 ISO 996 Annex A AB (3 hp) -3 (3 hp) (2 hp) -2-B (15 hp) (1 hp) -1-A (7.5 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

66 6 475S (475 gpm) [m] (125 hp) -12 (125 hp) -11 (1 hp) -1 (1 hp) 475S 6 z, SF 1.15 ISO 996 Annex A 9-9 (1 hp) (75 hp) (6 hp) -6 (6 hp) (5 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

67 6 475S (475 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -5-B (4 hp) (4 hp) AB (3 hp) (3 hp) (2 hp) B (15 hp) (1 hp) -1-A (7.5 hp) Q [US GPM] Q [m³/h] TM

68 6 475S (475 gpm) pump power requirement () [kw] 1 9 [hp] S 6 z, SF 1.15 ISO 996 Annex A -13 (125 hp) (125 hp) 1-11 (1 hp) (1 hp) (1 hp) -8 (75 hp) (6 hp) (6 hp) 5-5 (5 hp) Q [US GPM] Q [m³/h] TM

69 6 475S (475 gpm) Pump model Nom. head 475S75-1A S S15-2B S S25-3A S S3-4AB 168 Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 475S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 475 gpm (5" NPT) Net weight (complete) [lb] (1183) (565) (618) 5.63 (143) 7.5 (179) (1183) (565) (618) 5.63 (143) 7.5 (179) (128) (59) (618) 5.63 (143) 7.5 (179) (128) (59) (618) 5.63 (143) 7.5 (179) (1454) (78) (746) 5.63 (143) 7.5 (179) (1454) (78) (746) 5.63 (143) 7.5 (179) (1529) 3.83 (783) (746) 5.63 (143) 7.5 (179) (1529) 3.83 (783) (746) 5.63 (143) 7.5 (179) (1712) 33. (838) (874) 5.63 (143) 7.5 (179) (1712) 33. (838) (874) 5.63 (143) 7.5 (179) (1777) (93) (874) 5.63 (143) 7.5 (179) (1777) (93) (874) 5.63 (143) 7.5 (179) (195) (93) (12) 5.63 (143) 7.5 (179) (195) (93) (12) 5.63 (143) 7.5 (179) NPT B C E D 475S A 6.1 TM S (225) 4.28 (123) (12) 5.63 (143) 7.5 (179) E = Maximum diameter of pump including cable guard and motor. 475S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 475 gpm (6" NPT) 475S4-5B (2153) 4.28 (123) (113) 5.63 (143) 7.5 (179) S (2555) (1425) (113) 5.67 (144) 7.5 (179) S5-6A (2683) (1425) (1258) 5.67 (144) 7.5 (179) S (1272) 7.5 (179) 475S (14) 7.5 (179) 475S - Motor dia. 8 inch, 3 wire motor, 6 z, rated flow 475 gpm (6" NPT) 475S * (2126) (111) 4. (116) 7.56 (192) 8.8 (25) S4-5B * (2254) (111) 45.4 (1144) 7.56 (192) 8.8 (25) 475S * 9.71 (234) (116) 45.4 (1144) 7.56 (192) 8.8 (25) S5-6A * (2432) (116) 5.8 (1272) 7.56 (192) 8.8 (25) 475S * 1.8 (2542) 5. (127) 5.8 (1272) 7.56 (192) 8.8 (25) S * (267) 5. (127) (14) 7.56 (192) 8.8 (25) S * (2878) (135) 6.16 (1528) 7.56 (192) 8.8 (25) S * (3246) 62.6 (159) 65.2 (1656) 7.56 (192) 8.8 (25) S * (3374) 62.6 (159) 7.24 (1784) 7.56 (192) 8.8 (25) S * (352) 62.6 (159) (1912) 7.56 (192) 8.8 (25) S * (387) 72.5 (183) 8.32 (24) 7.56 (192) 8.8 (25) S * (3998) 72.5 (183) (2168) 7.56 (192) 8.8 (25) 76.7 Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 8 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 69

70 6 625S (625 gpm) [m] (1 hp) -4-A (75 hp) -4-AA (75 hp) -3 (6 hp) 625S 6 z, SF 1.15 ISO 996 Annex A A (6 hp) AA (5 hp) 3-2 (4 hp) A (4 hp) AA (3 hp) (25 hp) -1-A (15 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

71 6 625S (625 gpm) [m] (15 hp) -7-A (15 hp) -7-AA (125 hp) -6 (125 hp) 625S 6 z, SF 1.15 ISO 996 Annex A AA (125 hp) (1 hp) -5-A (1 hp) -5-AA (1 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

72 6 625S (625 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -4 (1 hp) -4-A (75 hp) AA (75 hp) (6 hp) A (6 hp) AA (5 hp) -2 (4 hp) A (4 hp) AA (3 hp) -1 (25 hp) A (15 hp) Q [US GPM] Q [m³/h] TM

73 6 625S (625 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -7 (15 hp) A (15 hp) -7-AA (125 hp) -6 (125 hp) AA (125 hp) -5 (1 hp) 1-5-A (1 hp) AA (1 hp) Q [US GPM] Q [m³/h] TM

74 6 625S (625 gpm) Pump model Nom. head 625S15-1A S S3-2AA 13 Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 625S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 625 gpm (6" NPT) Net weight (complete) [lb] (1359) (78) (651) 5.63 (143) 8.31 (211) (1359) (78) (651) 5.63 (143) 8.31 (211) (1489) 33. (838) (651) 5.63 (143) 8.31 (211) (1489) 33. (838) (651) 5.63 (143) 8.31 (211) (171) (93) (87) 5.63 (143) 8.31 (211) (171) (93) (87) 5.63 (143) 8.31 (211) S4-2A (183) 4.28 (123) (87) 5.63 (143) 8.31 (211) S (183) 4.28 (123) (87) 5.63 (143) 8.31 (211) S5-3AA (2388) (1425) (963) 5.63 (143) 8.31 (211) S6-3A (963) 8.31 (211) 625S (963) 8.31 (211) 625S - Motor dia. 8 inch, 3 wire motor, 6 z, rated flow 625 gpm (6" NPT) A B C 625S E D NPT TM S * 76.3 (1931) (111) (821) 7.56 (192) 8.39 (213) S5-3AA * (2123) (116) (963) 7.56 (192) 8.39 (213) E = Maximum diameter of pump 625S6-3A * (2233) 5. (127) (963) 7.56 (192) 8.39 (213) 49.8 including cable guard and motor. 625S * (2233) 5. (127) (963) 7.56 (192) 8.39 (213) S75-4AA * (2469) (135) 44.6 (1119) 7.56 (192) 8.39 (213) S75-4A * (2469) (135) 44.6 (1119) 7.56 (192) 8.39 (213) S * (279) 62.6 (159) 44.6 (1119) 7.56 (192) 8.39 (213) AA * (2864) 62.6 (159) 5.16 (1274) 7.56 (192) 8.39 (213) S1-5A * (2864) 62.6 (159) 5.16 (1274) 7.56 (192) 8.39 (213) S * (2864) 62.6 (159) 5.16 (1274) 7.56 (192) 8.39 (213) S125-6AA * (3259) 72.5 (183) (1429) 7.56 (192) 8.39 (213) S * (3259) 72.5 (183) (1429) 7.56 (192) 8.39 (213) S125-7AA * (3415) 72.5 (183) (1585) 7.56 (192) 8.39 (213) S15-7A * (3645) (26) (1585) 7.56 (192) 8.39 (213) S * (3645) (26) (1585) 7.56 (192) 8.39 (213) Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 1 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 74

75 6 8S (8 gpm) [m] (75 hp) -3-A (75 hp) -3-AA (6 hp) 8S 6 z, SF 1.15 ISO 996 Annex A (5 hp) A (5 hp) -2-AA (35 hp) (3 hp) -1-A (2 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

76 6 8S (8 gpm) [m] (125 hp) -5-A (125 hp) -5-AA (125 hp) 8S 6 z, SF 1.15 ISO 996 Annex A 2-4 (1 hp) 6-4-A (1 hp) -4-AA (1 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] 4 2 TM

77 6 8S (8 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -3 (75 hp) A (75 hp) -3-AA (6 hp) (5 hp) A (5 hp) AA (35 hp) (3 hp) A (2 hp) Q [US GPM] Q [m³/h] TM

78 6 8S (8 gpm) pump power requirement () [kw] [hp] S 6 z, SF 1.15 ISO 996 Annex A -5 (125 hp) -5-A (125 hp) AA (125 hp) (1 hp) A (1 hp) AA (1 hp) Q [US GPM] Q [m³/h] TM

79 6 8S (8 gpm) Pump model Nom. head 8S2-1A 64 8S Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 8S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 8 gpm (6" NPT) Net weight (complete) [lb] (1435) 3.83 (783) (652) 5.63 (143) 8.31 (211) (1435) 3.83 (783) (652) 5.63 (143) 8.31 (211) (1555) (93) (652) 5.63 (143) 8.31 (211) (1555) (93) (652) 5.63 (143) 8.31 (211) S4-2AA (183) 4.28 (123) (87) 5.63 (143) 8.31 (211) S5-2A (2235) (1425) (81) 7.56 (192) 8.39 (213) S (2235) (1425) (81) 7.56 (192) 8.39 (213) S6-3AA (963) 8.39 (213) 8S - Motor dia. 8 inch, 3 wire motor, 6 z, rated flow 8 gpm (6" NPT) 8S4-2AA * (1917) (111) (87) 7.56 (192) 8.39 (213) S5-2A * (1967) (116) (87) 7.56 (192) 8.39 (213) S * (1967) (116) (87) 7.56 (192) 8.39 (213) 438. A B C 8S E NPT D TM S6-3AA * (2233) 5. (127) (963) 7.56 (192) 8.39 (213) S75-3A * 91.7 (2313) (135) (963) 7.56 (192) 8.39 (213) E = Maximum diameter of pump 8S * 91.7 (2313) (135) (963) 7.56 (192) 8.39 (213) including cable guard and motor. 8S1-4AA * (278) 62.6 (159) 44.2 (1118) 7.56 (192) 8.39 (213) S1-4A * (278) 62.6 (159) 44.2 (1118) 7.56 (192) 8.39 (213) S * (278) 62.6 (159) 44.2 (1118) 7.56 (192) 8.39 (213) S125-5AA * (314) 72.5 (183) 5.16 (1274) 7.56 (192) 8.39 (213) S125-5A * (314) 72.5 (183) 5.16 (1274) 7.56 (192) 8.39 (213) S * (314) 72.5 (183) 5.16 (1274) 7.56 (192) 8.39 (213) Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 1 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 79

80 6 11S (11 gpm) [m] (125 hp) -3-A (125 hp) -3-AA (1 hp) 11S 6 z, SF 1.15 ISO 996 Annex A (1 hp) A (75 hp) AA (6 hp) (4 hp) A (3 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

81 6 11S (11 gpm) [m] (25 hp) -6-A (25 hp) -6-AA (25 hp) -5 (2 hp) -5-A (175 hp) 11S 6 z, SF 1.15 ISO 996 Annex A AA (175 hp) -4 (15 hp) A (15 hp) -4-AA (15 hp) Q [US GPM] [m] Q [m³/h] Eff Eff [%] NPS Q [US GPM] TM

82 6 11S (11 gpm) pump power requirement () [kw] 1 9 [hp] S 6 z, SF 1.15 ISO 996 Annex A -3 (125 hp) A (125 hp) AA (1 hp) (1 hp) A (75 hp) AA (6 hp) (4 hp) (3 hp) Q [US GPM] Q [m³/h] TM

83 6 11S (11 gpm) pump power requirement () [kw] 2 18 [hp] S 6 z, SF 1.15 ISO 996 Annex A -6 (25 hp) -6-A (25 hp) AA (25 hp) (2 hp) -5-A (175 hp) 18-5-AA (175 hp) (15 hp) -4-A (15 hp) AA (15 hp) Q [US GPM] Q [m³/h] TM

84 6 11S (11 gpm) Pump model Nom. head 11S3-1A 67 Ph Volts [V] Motor [p] Dimensions A B C D E [in (mm)] [in (mm)] [in (mm)] [in (mm)] [in (mm)] 11S - Motor dia. 6 inch, 3 wire motor, 6 z, rated flow 11 gpm (6" NPT) Net weight (complete) [lb] (1693) (93) (79) 5.63 (143) 9.3 (236) (1693) (93) (79) 5.63 (143) 9.3 (236) S (1813) 4.28 (123) (79) 5.63 (143) 9.3 (236) S6-2AA (966) 9.3 (236) 11S - Motor dia. 8 inch, 3 wire motor, 6 z, rated flow 11 gpm (6" NPT) 11S * (19) (111) (79) 7.56 (192) 9.41 (239) S6-2AA * 88.4 (2236) 5. (127) 38.4 (966) 7.56 (192) 9.41 (239) S75-2A * (2316) (135) 38.4 (966) 7.56 (192) 9.41 (239) S * 1.63 (2556) 62.6 (159) 38.4 (966) 7.56 (192) 9.41 (239) S1-3AA * (2732) 62.6 (159) (1142) 7.56 (192) 9.41 (239) S125-3A * (2972) 72.5 (183) (1142) 7.56 (192) 9.41 (239) S * (2972) 72.5 (183) (1142) 7.56 (192) 9.41 (239) A B C 11S E D NPT TM S15-4AA * 133. (3378) (26) (1318) 7.56 (192) 9.41 (239) S15-4A * 133. (3378) (26) (1318) 7.56 (192) 9.41 (239) E = Maximum diameter of pump 11S * 133. (3378) (26) (1318) 7.56 (192) 9.41 (239) including cable guard and motor. 11S175-5AA * (1494) 9.41 (239) 11S175-5A * (1494) 9.41 (239) 11S * (1494) 9.41 (239) 11S - Motor dia. 1 inch, 3 wire motor, 6 z, rated flow 11 gpm (6" NPT) 11S175-5AA (3364) (187) (1494) 9.34 (237) 9.85 (25) S175-5A (3364) (187) (1494) 9.34 (237) 9.85 (25) S (3564) 81.5 (27) (1494) 9.34 (237) 9.85 (25) S25-6AA (47) (24) (167) 9.34 (237) 9.85 (25) S25-6A (47) (24) (167) 9.34 (237) 9.85 (25) S (47) (24) (167) 9.34 (237) 9.85 (25) Notes: Control box is required for 3-wire, single-phase applications. Data does not include control box. Performance conforms to ISO 996 Annex 1 ft. minimum submergence. MS42 motor. MS4 motor. MS6 motor. MMS6 motor. MMS8 motor. Takes MS6 motor; not available as complete. Takes MMS6 motor; not available as complete. * Takes MMS8 motor; not available as complete. Takes MMS1 motor; not available as complete. 84

85 6 Electrical data Grundfos submersible pump motors - 6 z p Ph Volt [V] S.F. 4-inch, single-phase, 2-wire motors (control box not required) Grundfos submersible pump motors - 6 z Circuit breaker Amperage Full load Max. thrust Std. Delay Start [A] Max. [A] Eff. [%] PF [%] [lbs] Nameplate number Product number inch, single-phase, 3-wire motors inch, three-phase, 3-wire motors inch, three-phase, 3-wire motors inch, three-phase, 3-wire motors inch, three-phase, 3-wire motors Other motor manufacturers itachi motors: Refer to the itachi submersible motors application maintenance manual. Franklin motors: Refer to the Franklin submersible motors application maintenance manual. 85

86 7 Accessories 7. Accessories MP 24 The MP 24 is an electronic motor protector, designed for the protection of an asynchronous motor or a pump. The motor protector consists of: a cabinet incorporating transformers and electronics a control panel with operating buttons and display for reading of data. The MP 24 operates with two sets of limits: a set of warning limits and a set of trip limits. If one or more of the warning limits are exceeded, the motor continues to run, but the warnings will appear in the MP 24 display. Some values only have a warning limit. The warning can also be read out by means of the Grundfos R1 remote control. If one of the trip limits is exceeded, the trip relay will stop the motor. At the same time, the signal relay is operating to indicate that the limit has been exceeded. Many monitoring options The MP 24 monitors the following parameters: Insulation resistance before start-up Temperature (Tempcon, Pt sensor and PTC/thermal switch) Overload/underload Overvoltage/undervoltage Phase sequence Phase failure Power factor Power consumption armonic distortion Operating hours and number of starts. Applications The MP 24 can be used as a stand-alone motor protector. The MP 24 can be monitored via a Grundfos GENIbus. The power supply to the MP 24 is in parallel with the supply to the motor. Motor currents up to 12 A are passed directly through the MP 24. The MP 24 protects the motor primarily by measuring the motor current by means of a true RMS measurement. The MP 24 disconnects the contactor if, for example, the current exceeds the preset value. Secondarily, the motor is protected via temperature measuring by a Tempcon sensor, a Pt1/Pt1 sensor and a PTC sensor/thermal switch. The MP 24 is designed for single- and three-phase motors. In single-phase motors, the starting and run capacitors are also measured. Cos is measured in both single- and three-phase systems. Fig. 21 MP 24 Five sizes of single-turn transformers, A. Note: Monitoring of motor temperature is not possible when single-turn transformers are used. Fig. 22 Single-turn transformers Product numbers TM TM Benefits The MP 24 offers these benefits: Suitable for both single- and three-phase motors Dry-running protection Overload protection Very high accuracy Made for submersible pumps. Product Product number MP R

87 7 Functions Phase-sequence monitoring Indication of current or temperature (user selection) Indication of temperature in F or C (user selection) 4-digit, 7-segment display Setting and status reading with the R1 Setting and status reading via the GENIbus. Tripping conditions Overload Underload (dry running) Temperature (Tempcon sensor, PTC/thermal switch and Pt sensor) Phase failure Phase sequence Overvoltage Undervoltage Power factor (cos ) Current unbalance. Warnings Overload Underload Temperature (Tempcon and Pt sensor) Overvoltage Undervoltage Power factor (cos ) Note: In connection with single- and three-phase connection. Run capacitor (single-phase operation) Starting capacitor (single-phase operation) Loss of communication in network armonic distortion. Learning function Phase sequence (three-phase operation) Run capacitor (single-phase operation) Starting capacitor (single-phase operation) Identification and measurement of Pt1/Pt1 sensor circuit. External current transformers When fitted with external current transformers, the MP 24 unit can handle currents from 12 to 999 A. Grundfos can supply approved current transformers from stock (2/5A, 3/5A, 5/5A, 75/5A, 1/5A). Remote control R1 The R1 remote control from Grundfos allows for wireless infrared remote control of your MP 24 unit. With the R1, you get access to a full range of options such as factory setting adjustment, service and fault finding. Ready for bus communication The MP 24 allows for monitoring and communication via GENIbus a Grundfos-designed bus for exchange of pump data, alarms, status information, and setpoints. This enables users to connect the MP 24 to, for instance, SCADA systems. Accessories 87

88 7 Accessories Technical data - MP 24 Enclosure class IP 2 Ambient temperature 4 F to +14 F ( 2 C to +6 C) Relative air humidity 99% Voltage range 1-48 VAC Current range A Frequency 5 to 6 z IEC trip class 1-45 Special Grundfos trip class.1 to 3 s Voltage variation 25 %/+15 % of nominal voltage Approvals EN 6947, EN 6335, UL/CSA 58 Marking CE, cul, C-tick Consumption Max. 5 W Plastic type Black PC / ABS Measuring range Accuracy Resolution Current without external current transformers 3-12 A ±1 %.1 A Current with external current transformers A ±1 % 1 A Phase-to-phase voltage 8-61 VAC ±1 % 1 V Frequency z ±1 %.5 z Power -1 MW ±2 % 1 W Power factor -.99 ±2 %.1 Energy consumption -4x1 9 kwh ±5 % 1 kwh IO 112 Description Product number The IO 112 is a measuring module and a 1-channel protection unit for use in connection with the MP 24 motor protection unit. The module can be used for protection of pump against other factors than the electrical conditions, for instance dry-running. It can also be used as a stand-alone protection module. The IO 112 interface has three inputs for measured values one potentiometer for setting of limits indicator lights indicating the measured value of the input value of the limit set alarm source pump status Electrical data: Supply voltage: 24 VAC ±1% 5/6 z or 24 VDC ±1% Supply current: Min. 2.4 A; max. 8 A Power consumption:max. 5 W Ambient temperature: 13 F to+149 F ( 25 C to +65 C) Enclosure class: IP 2 88

89 7 Control functions This table describes the protection provided by MP 24. Control parameters Function Problem Advantages MS The motor temperature is measured by means of the built-in Tempcon temperature transmitter and a signal is sent to MP 24 via the phase leads. In MP 24 the measured temperature is compared with the factory-set value (167 F (75 C)). Overload, frequent starts/stops, operation against blocked discharge pipe, insufficient flow velocity past the motor. Longer motor life, safe operating conditions, service indication. Accessories Temperature Overvoltage/ undervoltage Overload Underload (dry running) Current unbalance Phase sequence Phase failure MMS The motor temperature is measured by means of the Pt1. The signal is sent to the MP 24 where the measured temperature is compared with the factory-set value. Temperature protection requires a submersible motor with a Pt1. The motor temperature must be monitored during frequency converter operation. If the set trip value is exceeded, the motor will stop. The motor power input is measured on each of the three phases. The registered power input is an average of these three values. If the factory-set value is exceeded, the motor will stop. The motor power input is measured on each of the three phases. The registered power input is an average of these three values. If the average value is lower than the factory-set value, the motor will stop. The power input of the motor is measured on each of the three phases. MP 24 and motor are installed so that the phase sequence corresponds to correct direction of rotation. MP 24 monitors changes in the phase sequence. MP 24 checks the phases connected, phase failure will cause an alarm. The installation is close to a transformer. The mains do not absorb load variations. Incorrect sizing of pump/motor, voltage supply failure, defective cable, blocking, wear or corrosion. Pump exposed to dry running or underload, for example caused by wear. Mains load is uneven, incipient motor defect, phase voltages diverging. Two phases are wrongly connected. Phase failure Important installation parameter, possibility of improving operating conditions. Longer pump life, safe operating conditions, service indication. Traditional dry-running protection is no longer necessary, no extra cables. Motor protection against overload, service indication. Ensures correct pump performance. Indication of phase failure, and alarm. 89

90 7 Accessories R1 menus. GENERAL See the operating instructions for the R1. 1. OPERATION Operating mode Actual trip Actual warning 1 Actual warning 2 Alarm log 1 Alarm log 2 Alarm log 3 Alarm log 4 Alarm log STATUS Display of Supply overview Average current Average voltage Tempcon sensor Pt1/Pt1 sensor Power input and energy consumption (described in the following) Energy trip counter Phase sequence Current unbalance Operating hours and number of starts Trip counter of hours and starts Starting capacitor Run capacitor Insulation resistance Cos armonic distortion. 3. LIMITS Display and setting of warning and trip limits. Tempcon sensor Pt sensor Tripping current Current warning Nominal voltage Voltage limits Current unbalance Starting capacitor Run capacitor Insulation resistance Cos trip Cos warning. 4. INSTALLATION Setting and display of Supply mains Trip class (described in the following) Trip delay External current transformers Power-on delay Restarting (described in the following) Automatic restarting (described in the following) Tempcon sensor Pt sensor Insulation resistance measurement PTC/thermal switch Resetting of trip counters Service interval Number of automatic restarts Units/display MP 24 display GENIbus ID number Learning function. Power input and energy consumption Actual input power and motor energy consumption. The energy consumption is an accumulated value which cannot be reset. The power is calculated like this: U L1 L2 + U L2 L3 + U L3 L1 U average = V 3 I L1 + I L2 + I L3 I average = A 3 cos average cos L1 + cos L2 + cos L3 = P = U average I average 3 cos average W 9

91 7 Trip class Accessories Line 1: Select IEC trip class (1 to 45). If manual indication of trip delay in the case of overload is required, select trip class "P". Factory setting: Cls (trip class): P. Line 2: Select trip delay. Factory setting: Dly (trip delay): 1 s. Restarting Set whether restarting after tripping is to be Automatic (factory setting) Manual. Setting of time, see section "Automatic restarting". Automatic restarting Set the time after which the MP 24 is to attempt automatic restarting of motor after cut-out. The time runs from the moment when the value which triggered the fault has returned to normal. Factory setting: 3 s. 91

92 Port 1 POWER POWER MNC POWER GENI GENI TxD GENI RxD FAULT Genibus DI Service Main Network Connection Port 2 DCD RTS TxD1 RxD1 TxD2 RxD2 7 Accessories G1 gateway for communication with Grundfos products The G1 offers a wide selection of options for integration of Grundfos products provided with GENIbus interface into main control and monitoring systems. The G1 enables a pump installation to meet future demands for optimum pump operation in terms of reliability, operating costs, centralization and automation. GR594 Fig. 23 G1 Central management system Radio SMS Modem PLC Direct PROFIBUS-DP Radio 4 digital inputs Main network RS-232 Service port for PC eating MAGNA UPE TPE Water treatment UPS GENIbus Industry MP 24 CU 3 DME E- pump IO 351 Multi-E ydro MPC MGE E- pump MP 24 IO 351 Pump SQE Sensors Pump Sensors MP 24 Water supply Wastewater Pump IO112 MP 24 ydro MPC IO 351 Pump Sensor CU 3 SQE Multi-E MP 24 IO 351 Pump Sensors TM Fig. 24 Examples of G1 applications 92

93 Port 1 POWER POWER MNC POWER GENI GENI TxD GENI RxD FAULT Genibus DI Service Main Network Connection Port 2 DCD RTS TxD1 RxD1 TxD2 RxD2 7 Product description The G1 Gateway enables communication of operating data, such as measured values and setpoints, between Grundfos products with GENIbus interface and a main network for control and monitoring. As indicated in the illustration on page 92, the G1 is suitable for use in applications such as water supply, water treatment, wastewater, building automation and industry. Common to above applications is that downtime is usually costly, and extra investments are therefore often made to achieve maximum reliability by monitoring selected operating variables. The day-to-day operation, such as starting and stopping of pumps and changing of setpoints, can also be effected from the main system by communication with the G1. In addition, the G1 can be set up to send event-controlled status indications such as alarms via the SMS to mobile phones, and to make automatic alarm call-backs to a central management system. Data logging Besides the possibility of data communication, the G1 offers logging of up to 35, time-stamped data. The logged data can be transmitted to the main system or a PC for further analysis in a spreadsheet or similar program. For the data logging, the "PC Tool G1 Data Log" software tool is used. The tool is part of the PC Tool G1 package, which is supplied with the G1. Other features Four digital inputs. Stop of all pumps in case of failing communication with the management system (optional). Access code for modem communication (optional). Alarm log. Installation Installation of the G1 is effected by the system integrator. The G1 is connected to the GENIbus as well as to the main network. All units on the GENIbus can thus be controlled from a central management system on the main network. The "G1 Support Files" CD-ROM supplied with the G1 contains examples of programs to be used when the G1 is connected to the various main network systems. Included is also a description of the data points available in Grundfos products with GENIbus interface. Fig. 25 Dimensional sketch Technical data Overview of protocols Main system PROFIBUS-DP Radio Modem PLC GSM mobile phone Other possible connections GENIbus RS-485: Service port RS-232: Accessories PC Tool G1 package (supplied with the product) G1 Support Files CD-ROM (supplied with product) Product numbers Software protocol DP Digital inputs: 4. Voltage supply: * CD-ROM with G1 Support Files included. Satt Control COMLI/Modbus Satt Control COMLI/Modbus Satt Control COMLI/Modbus SMS, UCP Connection of up to 32 units. TM For direct connection to a PC or via radio modem. 1 x V, 5/6 z. Ambient temperature: In operation: 4 F to +14 F ( 2 C to +6 C). Enclosure class: IP 2. Weight: Product 227 mm 73 mm 165 mm 1.8 kg. Product number G1 with Profibus-DP expansion board* G1 with Radio/Modem/PLC expansion board* G1 Basic Version* PC Tool G1 package Accessories The "PC Tool G1" software tool included can be used for the installation and use of G1. 93

94 7 Accessories Connecting pieces The tables below show the range of connecting pieces for connection of thread-to-flange and thread-to-thread. Thread-to- thread B L A TM GrA2555 Fig. 26 Dimensional sketch and photo of connecting piece thread-to-thread Type 385S 475S Connecting piece Thread-to-thread A Dimensions B L [in (mm)] 34 stainless steel Product number 316 stainless steel NPT 5 NPT 4 NPT 5 NPT (121) NPT 5 NPT 6 NPT 5 NPT (15) S 8S 11S NPT 6 NPT 5 NPT 6 NPT (15)

95 7 Zinc anodes Application Cathodic protection by means of zinc can be used for corrosion protection of pumps in chloride-containing liquids such as brackish water and seawater. Sacrificial anodes are placed on the outside of the pump and motor as protection against corrosion. The number of anodes required depends on the pump and motor in question. Please contact Grundfos for further details. Product numbers of zinc anodes Product number 5S to 75S 85S Zinc anodes for pumps 15S Used for pump type 23S S 385S 475S 625S 8S 11S Accessories Liquid temperatures Seawater: Up to 95 F (35 C). Brackish water (min. 15 ppm (g/m 3 ) chloride): Up to 95 F (35 C). Anode life The zinc anodes have a life of one to four years, depending on operating conditions (temperature, flow and chloride content). Zinc anodes for motors 4" motors 6" motors 8" motors 1" motors

96 7 Accessories SA-M 5 control boxes Application SA-M 5 control boxes are used as starting units for single-phase, 3-wire motors, types MS 42B with power input lower than or equal to 1.5 hp (1.1 kw). SA-M 5 is available in two versions, standard and DeLuxe. The standard version incorporates a motor -protective circuit breaker and thus protects the motor against overload. The DeLuxe version is identical to the standard version with the following addition a motor contactor is included for connection and disconnection of the power supply. Technical data Enclosure class: IP 42. Ambient temperature: 4 F to +14 F ( 2 C to +6 C). Relative humidity: Maximum 95 %, normal non-aggressive atmosphere. Product numbers Product 1 x V Description Product number SA-M 5 (Standard version) SA-M 5 (DeLuxe version) SA-M 5 (Standard version) SA-M 5 (DeLuxe version) SA-M 5 (Standard version) SA-M 5 (DeLuxe version) SA-M 5 (Standard version) SA-M 5 (DeLuxe version) TM hp 2. hp 3. hp 5. hp Fig. 27 SA-M 5 control box 96

97 7 Pt1 The Pt1 sensor offers these features: Continuous monitoring of the motor temperature Protection against too high motor temperature. Protecting the motor against too high motor temperature is the simplest and cheapest way of avoiding that motor lifetime is reduced. Pt1 ensures that operating conditions are not exceeded and indicates when it is time for service of the motor. Monitoring and protection by means of Pt1 require the following parts: Pt1 sensor Relay, type PR 5714 Cable. The PR 5714 relay is fitted with a Pt1 module. For both relays the following temperature limits are preset on delivery: +6 C (+14 F) warning limit +75 C (+167 F) stop limit. Technical data Enclosure class Ambient temperature Relative humidity Voltage variation Approvals Mark Relay type PR 5714 IP 65 (mounted in a control panel) 4 F to +14 F ( 2 C to +6 C) 95 % (condensating) 1 x VAC ±1 %, 5-6 z VDC ±2 %. UL, DNV CE Accessories Pt1 sensor with/without PR 5714 relay and cable Cable length [ft (m)] PR 5714 MS6 Product number MMS 6, MMS 8 MMS 1, MMS (2) Yes (4) Yes (6) Yes (8) Yes (1) Yes (2) No (4) No (6) No (8) No (1) No PR 5714 relay Voltage Product number VAC, 5/6 z / VDC Pt1 sensor including cable Cable length [ft (m)] MS6, MMS 6, MMS 8 Product number MMS 1 MMS (2) (4) (6) (8) (1) Staybolts for Pt1 Description Product number Bolt KIT for Pt1 (for MS6)

98 8 Energy consumption 8. Energy consumption Energy consumption of submersible pumps The percentage distribution of service life costs of a submersible pump for water supply is: 5 % initial costs (pump) 85 % operating costs / energy consumption 1 % maintenance costs. It is obvious that the highest savings can be achieved within energy consumption! The annual energy consumption, E, of a submersible pump can be calculated as follows: E = c x h x P 1 (USD) c = specific energy price (USD/kWh) h = operating hours/year (hours) P 1 = power input of the submersible pump (hp). Example: Calculation of the annual energy consumption of the submersible pump, type 625S S-3 with MS 8, 6 hp, 3 x 46 V, 6 z. Duty point: Flow rate: Total head: Q = 528 GPM = 335 ft Specific energy price:c = USD.15/kWh (consisting of day and night rate) Operating hours/year: h = 32. Q = GPM = ft Density = lb/ft 3 (assumed 1) 367 = conversion factor motor = (example 84.5 %, in equation.845) pump Q P 1 = in kw 367 pump motor = (not to be confused with the stage efficiency curve). By showing the P 2 /Q curve we make it easier for you to calculate the energy consumption. Calculation of motor efficiency at duty point As standard the 625S-3 is equipped with a 6 hp (45 kw for P1) MS6 motor. At duty point (Q = 528 GPM) the pump requires 59 hp (44 kw for P1), thus: a motor load of 87 % (44 kw / 45 kw) and a power reserve of 2 %. From the table on page 72 the motor efficiency can be read as: 84.6 % at a load of 75 %. ( 75 % ) 85.6 % at a load of 1 %. ( 1 % ) The interpolated value in this example is motor = 85.1 %, motor =.851. P = = 51.7 kw.851 E =.15 USD/kWh x 32 h x 51.7 kw. The annual energy costs amount to USD The pay-off time, A, (months) is calculated as follows: Purchase price of energy efficiency pump A = Energy savings/year Cable sizing In order to obtain an economical duty of the pump the voltage drop should be low. Today large water works already size cables for a maximum voltage drop of 1 %). The hydraulic resistance in the discharge pipe should be as low as possible. P P 1 = motor P 2 = 35 hp (power requirement of 625S-3 pump at 88 GPM, from curve P 2 / Q. 98

99 9 9. Cables Grundfos offers submersible drop cables for all applications: 3-core cable, 4-core cable, single leads. Cables for Grundfos 4" submersible motors are available with or without plugs. The submersible drop cable is chosen according to application and type of installation. Standard version: ot water version: Max. liquid temperature +14 F +6 C). Max. liquid temperature +158 F (+7 C), for short periods up to 194 F (+9 C) (for MS only). Tables indicating cable dimension in borehole The tables indicate the maximum length of drop cables in meters from motor starter to pump at direct-on-line starting at different cable dimensions. If star/delta starting is used the current will be reduced by 3 (I x.58), meaning that the cable length may be 3 longer (L x 1.73) than indicated in the tables. If for example the operating current is 1 % lower than the full-load current, the cable may be 1 % longer than indicated in the tables. The calculation of the cable length is based on a maximum voltage drop of 1 % to 3 % of the rated voltage and a water temperature of maximum +86 F (3 C). In order to minimize operating losses the cable cross section may be increased compared to what is indicated in the tables. This is economical only if the borehole provides the necessary space, and if the operational time of the pump is long, especially if the operating voltage is below the rated voltage. The table values are calculated on the basis of the formula: Max. cable length of a single-phase submersible pump: Max. cable length of a three-phase submersible pump: where U = Rated voltage [V] U = Voltage drop [%] I = Rated current of the motor [A] q = Cross-section of submersible drop cable [in 2 ] X L = Inductive resistance:.24 x 1-3 [/ft] cos= Power factor sin= L L = = Specific resistance: 9.5 X 1-6 [ in 2 /ft] Example Motor size: 4 hp, MMS 8 Rated current: Rated voltage: U U = ft I 2 1 cos -- + sin X q L U U ft I cos -- + sin X q L 1 cos A 3 x 46 V, 6 z Starting method: Direct-on-line Power factor: cos =.85 Voltage drop: 3 % Cross-section:.25 in 2 sin:.53 Cables 46 3 = L = 37 ft Cable dimensions at 1 x 22 V, 6 z Motor 4" hp I n [A] in 2 in 2 in 2 in 2 in Maximum cable length in feet from motor starter to pump. 99

100 9 Cables Cable sizing chart Motor rating 1 phase, 6 z Copper wire size Volts p Maximum motor cable length (motor service to entrance) [ft/m] (4) 21 (64) 34 (14) 54 (165) 84 (256) 13 (396) 196 (597) 291 (887).5 1 (3) 16 (49) 25 (76) 39 (119) 62 (189) 96 (293) 146 (445) 216 (658) (168) 88 (268) 139 (424) 219 (668) 34 (136) 525 (16) 796 (2426).5 4 (122) 65 (198) 12 (311) 161 (491) 251 (765) 388 (1183) 588 (1792).75 3 (91) 48 (146) 76 (232) 12 (366) 187 (57) 289 (881) 437 (1332) 647 (1972) (76) 4 (122) 63 (192) 99 (32) 154 (469) 238 (725) 361 (11) 536 (1634) 652 (1987) (58) 31 (94) 48 (146) 77 (235) 12 (366) 187 (57) 285 (869) 428 (135) 524 (1597) 2 15 (46) 25 (76) 39 (119) 62 (189) 97 (296) 153 (466) 236 (719) 362 (113) 448 (1366) 3 12 (37) 19 (58) 3 (91) 47 (143) 75 (229) 119 (363) 185 (564) 289 (881) 361 (11) 5 18 (55) 28 (85) 45 (137) 71 (216) 111 (338) 174 (53) 217 (661) (61) 31 (94) 49 (149) 75 (229) 114 (347) 141 (43) 1 25 (76) 39 (119) 6 (183) 93 (283) 116 (354) 3 phase, 6 z Motor rating Copper wire size Volts p Maximum motor cable length (motor service to entrance) [ft/m] (94) 5 (152) 79 (241) 126 (384) 2 24 (73) 39 (119) 61 (186) 97 (296) 152 (463) 3 18 (55) 29 (88) 47 (143) 74 (226) 116 (354) 181 (552) 5 17 (52) 28 (85) 44 (134) 69 (21) 18 (329) 166 (56) (61) 31 (94) 49 (149) 77 (235) 118 (36) 177 (539) 1 23 (7) 37 (113) 57 (174) 88 (268) 133 (45) 164 (5) (76) 39 (119) 6 (183) 91 (277) 111 (338) 134 (48) 2 3 (91) 46 (14) 7 (213) 86 (262) 15 (32) 127 (387) (113) 57 (174) 7 (213) 84 (256) 13 (314) 117 (357) 3 31 (94) 47 (143) 58 (177) 7 (213) 85 (259) 97 (296) 111 (338) (11) 58 (177) 92 (28) 145 (442) 2 28 (85) 45 (137) 7 (213) 111 (338) 174 (53) 3 21 (64) 34 (14) 54 (165) 86 (262) 134 (48) 28 (634) 5 2 (61) 32 (98) 51 (155) 8 (244) 124 (378) 19 (579) (7) 36 (11) 57 (174) 89 (271) 135 (411) 23 (619) 1 27 (82) 42 (128) 66 (21) 11 (38) 152 (463) 187 (57) (88) 45 (137) 69 (21) 14 (317) 128 (39) 154 (469) 2 35 (17) 53 (162) 81 (247) 99 (32) 12 (366) 145 (442) (85) 43 (131) 65 (198) 8 (244) 97 (296) 117 (357) 134 (48) 3 35 (17) 54 (165) 66 (21) 8 (244) 97 (296) 111 (338) 127 (387) (518) 2 13 (396) 27 (631) 3 1 (35) 16 (488) 252 (768) 5 59 (18) 95 (29) 15 (457) 236 (719) (128) 68 (27) 17 (326) 169 (515) 264 (85) 1 31 (94) 5 (152) 79 (241) 125 (381) 196 (597) 35 (93) (165) 85 (259) 134 (48) 29 (637) 32 (975) 2 41 (125) 65 (198) 13 (314) 161 (491) 247 (753) 373 (1137) (162) 83 (253) 13 (396) 199 (67) 31 (917) 37 (1128) 3 43 (131) 68 (27) 17 (326) 164 (5) 249 (759) 36 (933) 37 (1128) 4 79 (241) 121 (369) 183 (558) 225 (686) 271 (826) 329 (13) 5 64 (195) 98 (299) 148 (451) 181 (552) 219 (668) 265 (88) 31 (917) 6 83 (253) 125 (381) 154 (469) 185 (564) 224 (683) 254 (774) 289 (881) (314) 126 (384) 152 (463) 185 (564) 21 (64) 24 (732) 1 94 (287) 113 (344) 138 (421) 156 (475) 179 (546) (329) 122 (372) 139 (424) (32) 119 (363) 2 18 (329) 13 (396) (329) 1

101 9 Motor rating Volts p 3 phase, 6 z Copper wire size Maximum motor cable length (motor service to entrance) [ft/m] Cables (799) 2 23 (619) (482) 253 (771) 5 92 (28) 148 (451) 233 (71) (21) 16 (323) 168 (512) 265 (88) 1 49 (149) 78 (238) 124 (378) 195 (594) (162) 85 (259) 134 (48) 29 (637) 2 65 (198) 13 (314) 161 (491) 252 (768) (158) 83 (253) 13 (396) 23 (619) 311 (948) 3 68 (27) 17 (326) 167 (59) 256 (78) 388 (1183) 4 79 (241) 124 (378) 19 (579) 286 (872) 351 (17) 5 1 (35) 154 (469) 231 (74) 284 (866) 342 (142) 6 85 (259) 13 (396) 196 (597) 24 (732) 289 (881) 35 (167) (323) 16 (488) 197 (6) 238 (725) 289 (881) 329 (13) CAUTION: Use of wire size smaller than listed will void warranty. Notes: 1. If aluminum conductor is used, multiply lengths by.5 Maximum allowable length of aluminum is considerably shorter than copper wire of same size. 2. The portion of the total cable which is between the service entrance and a 3ø motor starter should not exceed 25% of the total maximum length to assure reliable starter operation. Single-phase control boxes may be connected at any point of the total cable length. 3. Cables #14 to # are AWG sizes, and 25 to 3 are MCM sizes. 11

102 1 Friction loss tables 1. Friction loss tables Friction loss table - SC 4 steel pipe.5".75" 1" 1.25" 1.5" 2" 2.5" 3" 4" U.S. gpm U.S. gph ID.622" ID.824" ID 1.49" ID 1.38" ID 1.61" ID 2.67" ID 2.469" ID 3.68" ID 4.26" Friction loss in feet of head per 1 feet of pipe , , , , , , , , , , , , , , , , , ,

103 1 Friction loss table - SC 4 PVC pipe.5".75" 1" 1.25" 1.5" 2" 2.5" 3" 4" U.S. gpm U.S. gph ID.622" ID.824" ID 1.49" ID 1.38" ID 1.61" ID 2.67" ID 2.469" ID 3.68" ID 4.26" Friction loss in feet of head per 1 feet of pipe , , , , , , , , , , , , , , , , , , Friction loss tables Type of fitting and application Pipe and fitting Nominal size of fitting and pipe 1/2" 3/4" 1" 1.25" 1.5" 2" 2.5" Friction loss in equivalent length of straight pipe in feet Insert coupling Plastic Threaded adapter (plastic to thread) 9 standard elbow Standard tee (flow through run) Standard tee (flow through side) Plastic Steel Plastic Steel Plastic Steel Plastic Gate valve 1 Steel Swing check valve 1 Steel Notes: Based on Schedule 4 steel and plastic fittings 1 Friction loss figures are for screwed valves and are based on equivalent lengths of steel pipe. 13

104 11 Further product documentation 11. Further product documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on WebCAPS contains detailed information on more than 185, Grundfos products in more than 2 languages. In WebCAPS, all information is divided into 6 sections: Catalog Literature Service Sizing Replacement CAD drawings. Catalog This section is based on fields of application and pump types, and contains technical data curves (Q, Eta, P1,, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as product guides installation and operating instructions service documentation, such as Service kit catalog and Service kit instructions quick guides product brochures, etc. Service This section contains an easy-to-use interactive service catalog. ere you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 14

105 1 11 Sizing This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc. Replacement Further product documentation In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185, Grundfos products in more than 2 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 28 WinCAPS CD-ROM 15

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz GRUNDFOS DATA BOOKLET SP A, SP, motors and accessories 5 Hz Contents General data Performance range 3 Applications 4 Type key 4 Pumped liquids 4 Operating conditions 4 Curve conditions 4 Pump range 5 Motor

More information

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz GRUNDFOS DATA BOOKLET SP A, SP, motors and accessories 5 Hz Contents General data Performance range Page 3 Applications Page 4 Type key Page 4 Pumped liquids Page 4 Operating conditions Page 4 Curve conditions

More information

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz SP A, SP Submersible motors Accessories For raw water supply, irrigation systems, groundwater lowering, pressure boosting and various industrial applications. 5 Hz TM 7318 2298 Contents General data Performance

More information

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz GRUNDFOS DATA BOOKLET SP A, SP, motors and accessories 5 Hz Contents General data Performance range 3 Applications 4 Type key 4 Pumped liquids 4 Curve conditions 4 Pump range 5 Motor range 5 Motor protection

More information

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories. 50 Hz

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories. 50 Hz GRUNDFOS DATA BOOKLET SP A, SP Submersible pumps, motors and accessories 5 Hz SP A, SP Table of contents 1. General description 3 Performance range 3 Minimum efficiency index 4 Type key 4 Applications

More information

Contents. General Data. Submersible Motors

Contents. General Data. Submersible Motors Contents General Data Performance Range Page 2 Applications Page Type Key Page Pumped Liquids Page Operating Conditions Page Curve Conditions Page Pump Range Page Motor Range Page s Features and Benefits

More information

SP5A kW V 50Hz

SP5A kW V 50Hz GRUNDFOS DATA BOOKLET SP5A- 6 0.55kW 380-415V 50Hz Grundfos pump 5001906 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/spfam/5001906/sp-5a-6.html

More information

GRUNDFOS PRODUCT GUIDE CH, CHN. Horizontal multistage end-suction pumps

GRUNDFOS PRODUCT GUIDE CH, CHN. Horizontal multistage end-suction pumps GRUNDFOS PRODUCT GUIDE C, CN orizontal multistage endsuction pumps Contents General description Product description 3 Applications 3 Pumped liquids 3 Operating conditions 3 Pump 3 Motor 4 Performance range

More information

Submersible Pumps - HSP Series HIWAKI

Submersible Pumps - HSP Series HIWAKI Submersible Pumps - HSP Series HIWAKI The Company We are manufacturers innovative HIWAKI PUMPS, top-quality water pumps world-wide in different versions. Our very wide range of pumps can be used in many

More information

SP3A kW 1x220V 50Hz

SP3A kW 1x220V 50Hz GRUNDFOS DATA BOOKLET SP3A- 9.55kW 1x22V 5Hz Grundfos pump 1219 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/spfam/1219/sp-3a-9.html

More information

SP3A- 6N 2.2kW 1x220V 50Hz

SP3A- 6N 2.2kW 1x220V 50Hz GRUNDFOS DATA BOOKLET SP3A- 6N 2.2kW 1x22V 5Hz Grundfos pump 12216 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/spfam/12216/sp-3a-6n.html

More information

SP5A-25N 2.2kW 1x220V 50Hz

SP5A-25N 2.2kW 1x220V 50Hz GRUNDFOS DATA BOOKLET SP5A-25N 2.2kW 1x220V 50Hz Grundfos pump 5202125 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/spfam/5202125/sp-5a-25n.html

More information

SP9-11 Rp2 4"1X /50 2.2kW

SP9-11 Rp2 41X /50 2.2kW GRUNDFOS DATA BOOKLET SP9-11 Rp2 4"1X22-23/5 2.2kW Grundfos pump 9869924 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/spfam/9869924/sp-9-11.html

More information

SQ, SQE, CU 331, and SP

SQ, SQE, CU 331, and SP GRUNDFOS DATA BOOKLET SQ, SQE, CU 331, and SP Submersible pumps, motors, and accessories 6 z SQ, SQE, CU 331, and SP Table of contents 1. SQ, SQE introduction 4 SQ, SQE features and benefits 4 SQ, SQE

More information

Contents. General data. Technical data, SPK/CRK. General data, MTA(D) Technical data, MTA(D) General data, MTR. General data, MTC

Contents. General data. Technical data, SPK/CRK. General data, MTA(D) Technical data, MTA(D) General data, MTR. General data, MTC Contents General data Performance range page Product range page 6 General data, MTA(D) Performance range, MTA(D) page 8 Product description, MTA(D) page 9 Pumped liquids, MTA(D) page 9 Pump, MTA(D) page

More information

Contents. Accessories Pipework connection Counter flanges for LCR Counter flanges for LCRN

Contents. Accessories Pipework connection Counter flanges for LCR Counter flanges for LCRN Contents Product Data Introduction Performance range Minimum cost of ownership Applications Product range Pump Mor Terminal box positions Ambient temperature Viscosity Accessories Pipework connection Counter

More information

SP11-24 Rp2 4"3X /50 5.5kW

SP11-24 Rp2 43X /50 5.5kW GRUNDFOS DATA BOOKLET SP11-24 Rp2 4"3X38-415/5 5.5kW Grundfos Pump 98699318 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/spfam/98699318/sp-11-24.html

More information

Company name: Čerpadla NEPTUN Created by: Václav König Phone: Date:

Company name: Čerpadla NEPTUN Created by: Václav König Phone: Date: Position Qty. Description 1 SQ 2-55 Note! Product picture may differ from actual product Product No.: 9651199 3" multi-stage, submersible pump designed for domestic water supply, liquid transfer in tanks,

More information

Environmental Submersible Pumps

Environmental Submersible Pumps Environmental Submersible Pumps Grundfos 475S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated

More information

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE GRUNDFOS DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 5 z Irrigation Warehouse Group Pty Ltd iwgroup.com.au Ph 673 6333 Contents Product data Introduction 3 Performance

More information

Environmental Submersible Pumps

Environmental Submersible Pumps Environmental Submersible Pumps Grundfos 385S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated

More information

Shipping volume [ft 3 ] 3 SQF-2 47 * 2.9 1" NPT Dimensions [in] L B S 3 SQF-3 49 * 2.9 1" NPT

Shipping volume [ft 3 ] 3 SQF-2 47 * 2.9 1 NPT Dimensions [in] L B S 3 SQF-3 49 * 2.9 1 NPT Dimensions and weights ø5/16" ø8 S Pump type Dimensions [in] L B S Net weight [lb] Gross weight [lb] Shipping volume [ft 3 ] 3 SQF-2 47 * 2.9 1" NPT 17 21 0.85 3 SQF-3 49 * 2.9 1" NPT 17.5 21 0.85 6 SQF-2

More information

SP3A-15NE 1.1kW 3x V 50Hz

SP3A-15NE 1.1kW 3x V 50Hz GRUNDFOS DATA BOOKLET SP3A-15NE 1.1kW 3x380-415V 50Hz Grundfos pump 10221915 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/spne03/10221915/sp-3a-15ne.html

More information

GRUNDFOS PRODUCT GUIDE SQ, SQE, SQE-NE, CU 321

GRUNDFOS PRODUCT GUIDE SQ, SQE, SQE-NE, CU 321 GRUNDFOS PRODUCT GUIDE SQ, SQE, SQE-NE, CU 321 Contents Contents Product introduction Introduction 4 Features and benefits 4 Identification 6 Applications SQ with pressure switch and pressure tank 7 Constant-pressure

More information

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE GRUNDFOS DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 6 z Contents Product data Introduction 3 Performance range - CR, CRI, CRN Performance range - CRE, CRIE, CRNE Applications

More information

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE GRUNDFOS DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 6 z Contents Product data Introduction 3 Performance range - CR, CRI, CRN Performance range - CRE, CRIE, CRNE Applications

More information

Pipe connection All pump types have a treaded pipe connection: Rp2 1/2 for 6 WPS 16 N, Rp 3 for 6 WPS 30 N and Rp 4 for 6 WPS 45 N and 6 WPS 60 N.

Pipe connection All pump types have a treaded pipe connection: Rp2 1/2 for 6 WPS 16 N, Rp 3 for 6 WPS 30 N and Rp 4 for 6 WPS 45 N and 6 WPS 60 N. All the internal and external metal components of the 6 WPS N pumps are constructed of stainless steel AISI 316 throughout and are being cold pressed from stainless steel sheet. 6 WPS N submersible pumps

More information

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE GRUNDFOS DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 5 z Contents Product data Introduction 3 Performance range of CR, CRI, CRN Performance range of CRE, CRIE, CRNE

More information

GRUNDFOS DATA BOOKLET MTR(E), MTH, MTA. Immersible pumps 50/60 Hz

GRUNDFOS DATA BOOKLET MTR(E), MTH, MTA. Immersible pumps 50/60 Hz GRUNDFOS DATA BOOKLET MTR(E), MT, MTA Immersible pumps 5/6 z Contents Product data Introduction 4 Performance range - MTR, 5 z 5 Performance range - MTRE, 5 z 5 Performance range - MTR, 6 z 6 Performance

More information

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE GRUNDFOS DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical, multistage centrifugal pumps z CR, CRI, CRN, CRE, CRIE, CRNE Table of contents 1. Product data 3 Introduction 3 Performance range of CR, CRI,

More information

Lenntech. Lenntech SQ, SQ-N, SQE, SQE-N. Submersible pumps 50/60 Hz GRUNDFOS DATA BOOKLET. Tel.

Lenntech. Lenntech SQ, SQ-N, SQE, SQE-N. Submersible pumps 50/60 Hz GRUNDFOS DATA BOOKLET.  Tel. Lenntech GRUNDFOS DATA BOOKLET SQ, SQ-N, SQE, SQE-N Submersible pumps 50/60 Hz Lenntech info@lenntech.com info@lenntech.com Tel. Tel. +31-152-610-900 +31-152-610-900 www.lenntech.com www.lenntech.com Fax.

More information

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE GRUNDFOS DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 5 z Contents Product data Introduction 3 Performance range of CR, CRI, CRN Performance range of CRE, CRIE, CRNE

More information

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE Grundfos DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 5 z Contents Product data Introduction 3 Performance range of CR, CRI, CRN Performance range of CRE, CRIE, CRNE

More information

C.R.I.SUBMERSIBLE PUMPS 60Hz

C.R.I.SUBMERSIBLE PUMPS 60Hz C.R.I.SUBMERSIBLE PUMPS 6Hz An ISO 91, ISO 11 & OHSAS 181 Company Certified to NSF/ANSI 61-G For specific models only. GLOBAL QUALITY IN THE AMERICAN CONTEXT To make a break and establish a presence in

More information

SUBMERSIBLE PUMPS 6" STAINLESS STEEL SR SERIES FEATURES

SUBMERSIBLE PUMPS 6 STAINLESS STEEL SR SERIES FEATURES FEATURES Stainless steel impellers and diffusers to resist corrosion Heavy-duty stainless steel shell assures permanent alignment of all components to increase longevity and enables higher pressures than

More information

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR10-08 A-A-A-E-HQQE 3x400D 50 HZ Grundfos pump 96501230 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/96501230/cr-10-8-a-a-a-e-hqqe.html

More information

SUBMERSIBLE PUMPS 6" STAINLESS STEEL SR SERIES FEATURES SPECIFICATIONS APPLICATIONS

SUBMERSIBLE PUMPS 6 STAINLESS STEEL SR SERIES FEATURES SPECIFICATIONS APPLICATIONS FEATURES n Stainless steel impellers and diffusers to resist corrosion n Heavy-duty stainless steel shell assures permanent alignment of all components to increase longevity and enables higher pressures

More information

CR-H, CRN-H, CRE-H, CRNE-H

CR-H, CRN-H, CRE-H, CRNE-H GRUNDFOS PRODUCT GUIDE CR-, CRN-, CRE-, CRNE- orizontal end-suction multistage centrifugal pumps 6 z Contents Contents Mission 3 Product overview Introduction Performance range 5 Applications 6 Product

More information

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017 Position Qty. Description 1 CM5-4 S-R-I-E-AQQE Product No.: 98482185 Compact, reliable, horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The pump

More information

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz GRUNDFOS PRODUCT GUIDE Redi-Flo3 and CU 300 Environmental Pumps 60Hz Table of Contents Features and Benefits..................................... pages 4-5 Applications.............................................

More information

franklinwater.eu 50 HZ EH - EHsp SERIES HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS

franklinwater.eu 50 HZ EH - EHsp SERIES HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS franklinwater.eu 5 HZ EH - EHsp SERIES HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS INDEX Stainless Steel Horizontal Multistage (EH) and Self-Priming (EHsp) Pumps 2 Family curves 3 Pump identification

More information

GRUNDFOS PRODUCT GUIDE MS6. Submersible motors 50/60 Hz

GRUNDFOS PRODUCT GUIDE MS6. Submersible motors 50/60 Hz GRUNDFOS PRODUCT GUIDE Submersible motors 50/60 Hz Contents Mission Introduction General 5 Product variants 5 Features and benefits Features and benefits 6 Applications Applications 7 Identification Identification

More information

VERTICAL MULTI-STAGE PUMPS

VERTICAL MULTI-STAGE PUMPS VR SERIES - 6 HZ FEATURES All 316 stainless steel hydraulic components for superior durability, efficiency, and performance over a wide variety of applications Rugged NEMA motor mounting with oversized

More information

CR A-F-A-V-HBQV 3x400/ HZ

CR A-F-A-V-HBQV 3x400/ HZ GRUNDFOS DATA BOOKLET CR12-6-1 A-F-A-V-HBQV 3x4/69 5 HZ Grundfos Pump 95922172 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/95922172/cr-12-6-1-a-f-a-v-hbqv.html

More information

CM5-6 A-R-A-E-AQQE C-A-A-N

CM5-6 A-R-A-E-AQQE C-A-A-N GRUNDFOS DATA BOOKLET CM5-6 A-R-A-E-AQQE C-A-A-N Grundfos pump 97516572 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/97516572/cm5-6-a-r-a-e-aqqe.html

More information

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR1-1 A-A-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651232 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651232/cr-1-1-a-a-a-e-hqqe.html

More information

CRN10-09 A-FGJ-G-V-HQQV 3x400D 50 HZ

CRN10-09 A-FGJ-G-V-HQQV 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN1-9 A-FGJ-G-V-HQQV 3x4D 5 HZ Grundfos pump 9651394 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crn1/9651394/crn-1-9-a-fgj-g-v-hqqv.html

More information

Lowara. 8 Submersible Electric Pumps. 6Z855, 6Z875 6Z895, 6Z8125 Series. 60 Hz

Lowara. 8 Submersible Electric Pumps. 6Z855, 6Z875 6Z895, 6Z8125 Series. 60 Hz 8 Submersible Electric Pumps 6Z855, 6Z875 6Z895, 6Z8125 Series 60 Hz 6Z855, 6Z875, 6Z895, 6Z8125 SERIES HYDRAULIC PERFORMANCE RANGE AT 60 Hz PRINT 10-2006 2 CONTENTS 6Z8 Series Specifications...5 Table

More information

VERTICAL MULTI-STAGE PUMPS

VERTICAL MULTI-STAGE PUMPS VR SERIES - 6 HZ FEATURES All 316 SS hydraulic components for superior durability, efficiency, and performance over a wide variety of applications Rugged NEMA motor mounting with oversized ball bearings

More information

CR15-14 A-F-A-E-HQQE 3x400/ HZ

CR15-14 A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR15-1 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 965193 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/965193/cr-15-1-a-f-a-e-hqqe.html

More information

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE DWC PERFORMANCE CURVE DWC

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE DWC PERFORMANCE CURVE DWC CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 300 203 PERFORMANCE CURVE 500 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR1-5-1 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 95922155 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/95922155/cr-1-5-1-a-f-a-e-hqqe.html

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR12-4-1 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 95922154 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/95922154/cr-12-4-1-a-f-a-e-hqqe.html

More information

SQ kW V 50/60Hz 70M

SQ kW V 50/60Hz 70M GRUNDFOS DATA BOOKLET SQ 1-14 1.68kW 2-24V 5/6Hz 7M Grundfos pump 96524442 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sqc1/96524442/sq-1-14.html

More information

SS7 SUBMERSIBLE ELECTRIC PUMPS 7

SS7 SUBMERSIBLE ELECTRIC PUMPS 7 SS7 TECHNICAL DATA Performance range: flow up to 110 m3/h and max head of 423 m Max. quantity of sand/silt: 50g/m3 Max. ambient temperature: 30 C (50 C available on request) Outlet connection diameter

More information

Service instructions. MS6 3.7 kw - 30 kw. 50/60 Hz 3~

Service instructions. MS6 3.7 kw - 30 kw. 50/60 Hz 3~ Service instructions MS6 3.7 kw - 30 kw 50/60 Hz 3~ 1. Symbols used in this document... 2 2. Identification... 2 2.1 Nameplate... 2 2.2 Frequency converter operation... 2 2.3 Product number key... 3 2.4

More information

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz GRUNDFOS DATA BOOKLET Grundfos UPBasic Circulator pumps 50 Hz Contents General data Performance ranges Page Product range, 1 x 0 V, 50 Hz Page 4 Type key Page 4 Construction Page 4 Material specification

More information

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CR1-6 A-A-A-E-HQQE 3x23/4 5HZ Grundfos Pump 96516174 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96516174/cr-1-6-a-a-a-e-hqqe.html

More information

CRN120-3 A-F-G-V-HQQV 3x400/ HZ

CRN120-3 A-F-G-V-HQQV 3x400/ HZ GRUNDFOS DATA BOOKLET CRN12-3 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos pump 9592221 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crn12/9592221/crn-12-3-a-f-g-v-hqqv.html

More information

Series description: Wilo-Sub TWI 6-..-B

Series description: Wilo-Sub TWI 6-..-B Series description: Wilo-Sub TWI 6-..-B Design Submersible pump, multistage Application For water and potable water supply from boreholes and rainwater storage tanks Process water supply For municipal

More information

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CR1-3 A-A-A-E-HQQE 3x23/4 5HZ Grundfos Pump 9651617 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651617/cr-1-3-a-a-a-e-hqqe.html

More information

GRUNDFOS DATA BOOKLET SP-G. Submersible pumps, submersible motors, accessories 50 Hz

GRUNDFOS DATA BOOKLET SP-G. Submersible pumps, submersible motors, accessories 50 Hz GRUNDFOS DATA BOOKLET Submersible pumps, submersible motors, accessories 5 Hz Contents General data Performance range 3 Pump range 4 Motor range 4 Type key 4 Pumped liquids 4 Operating conditions 4 Maximum

More information

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz GRUNDFOS DATA BOOKLET CR15-1 A-F-A-E-HQQE 11kW 3x4D 5Hz Grundfos Pump 965191 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/965191/cr-15-1-a-f-a-e-hqqe.html

More information

CR A-F-A-V-HQQV 3x400/ HZ

CR A-F-A-V-HQQV 3x400/ HZ GRUNDFOS DATA BOOKLET CR64-7-1 A-F-A-V-HQQV 3x4/69 5 HZ Grundfos Pump 96123566 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123566/cr-64-7-1-a-f-a-v-hqqv.html

More information

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CR10-01 A-A-A-E-HQQE 1x220/ HZ GRUNDFOS DATA BOOKLET CR1-1 A-A-A-E-HQQE 1x22/24 5 HZ Grundfos Pump 965872 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/965872/cr-1-1-a-a-a-e-hqqe.html

More information

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ GRUNDFOS DATA BOOKLET CR1S-6 A-A-A-E-HQQE 1x22/24 5HZ Grundfos Pump 96531687 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96531687/cr-1s-6-a-a-a-e-hqqe.html

More information

SQ kW V 50/60Hz

SQ kW V 50/60Hz GRUNDFOS DATA BOOKLET SQ 5-7 1.85kW 2-24V 5/6Hz Grundfos pump 9651217 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sqc5/9651217/sq-5-7.html

More information

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ GRUNDFOS DATA BOOKLET CR3-13 A-A-A-E-HQQE 1x22/24 5HZ Grundfos Pump 9653816 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9653816/cr-3-13-a-a-a-e-hqqe.html

More information

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ GRUNDFOS DATA BOOKLET CR1-9 A-A-A-E-HQQE 1x2/240 HZ Grundfos Pump 96529477 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96529477/cr-1-9-a-a-a-e-hqqe.html

More information

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR45-1 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122815 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122815/cr-45-1-a-f-a-e-hqqe.html

More information

GRUNDFOS DATA BOOKLET. Fire CRFF. Grundfos fire systems. VdS-approved CR pumps for fire systems 50 Hz

GRUNDFOS DATA BOOKLET. Fire CRFF. Grundfos fire systems. VdS-approved CR pumps for fire systems 50 Hz GRUNDFOS DATA BOOKLET Fire CRFF Grundfos fire systems VdS-approved CR pumps for fire systems 5 Hz Fire CRFF Table of contents. Introduction to VdS 3 2. Product description Introduction Performance range

More information

GRUNDFOS MS MOTORS. Grundfos submersible motors in a class of their own. GRUNDFOS Control Box SA-SPM5

GRUNDFOS MS MOTORS. Grundfos submersible motors in a class of their own. GRUNDFOS Control Box SA-SPM5 GRUNDFOS MS MOTORS Grundfos submersible motors in a class of their own GRUNDFOS Control Box SA-SPM5 More than 30 years experience Grundfos has been manufacturing quality submersible motors for more than

More information

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CR120-2 A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 95922152 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/95922152/cr-12-2-a-f-a-e-hqqe.html

More information

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX DIMENSION TABLE MATRIX PACKING 403

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX DIMENSION TABLE MATRIX PACKING 403 CONTENTS Page - SPECIFICATIONS 200-201 SELECTION CHART 202 SELECTION CHART TABLE 203 TYPE KEY AND CURVE SPECIFICATIONS 204 PERFORMANCE CURVE 3 ( 2-3-4-5 IMPELLERS ) 205 PERFORMANCE CURVE 3 ( 6-7-8-9 IMPELLERS

More information

TP /2-A-F-A-BUBE 1X230 50HZ

TP /2-A-F-A-BUBE 1X230 50HZ GRUNDFOS DATA BOOKLET TP 8-12/2-A-F-A-BUBE 1X23 5HZ Grundfos pump 9642448 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/9642448/tp-8-12-2-a-f-a-bube.html

More information

SF6. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS. Page - CONTENTS 100

SF6. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS. Page - CONTENTS 100 SPECIFICATIONS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART 202 SELECTION CHART 203 PERFORMANCE CHART R10 204 PERFORMANCE CHART R13 205 PERFORMANCE CHART S25 206 PERFORMANCE

More information

Contents. Identification

Contents. Identification Contents Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole Construction Sectional drawing Construction features Test pressure Operating conditions

More information

60HZ EH SERIES HORIZONTAL MULTISTAGE PUMPS. etechpumps.com

60HZ EH SERIES HORIZONTAL MULTISTAGE PUMPS. etechpumps.com 6Z E SERIES ORIZONTAL MULTISTAGE PUMPS etechpumps.com INDEX E Stainless Steel orizontal Multistage Pump Family curves Materials/Fluids compatibility Table of hydraulic performances E SERIES E 3 E 5 E

More information

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRI15-4 A-FGJ-I-E-HQQE 3x4D 5 HZ Grundfos pump 9651913 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cri15/9651913/cri-15-4-a-fgj-i-e-hqqe.html

More information

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: CME3-7 A-S-I-E-AVBE. Pump Data

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: CME3-7 A-S-I-E-AVBE. Pump Data Submittal Data PROJECT: REPRESENTATIVE: ENGINEER: CONTRACTOR: UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: CME3-7 A-S-I-E-AVBE QUANTITY: DATE: DATE: DATE: CME are reliable, quiet and

More information

CR10-02 A-A-A-E-HQQE 3x230/ HZ

CR10-02 A-A-A-E-HQQE 3x230/ HZ GRUNDFOS DATA BOOKLET CR1-2 A-A-A-E-HQQE 3x23/4 5 HZ Grundfos Pump 96598 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96598/cr-1-2-a-a-a-e-hqqe.html

More information

EH -EHsp SERIES 50 Hz

EH -EHsp SERIES 50 Hz PRODUCT CATALOG EH -EHsp SERIES 5 Hz HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS franklinwater.eu INDEX STAINLESS STEEL HORIZONTAL MULTISTAGE (EH) AND SELF-PRIMING (EHsp) PUMPS... 2 Family curves...3

More information

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CR3-1 A-A-A-E-HQQE 3x23/4 5HZ Grundfos Pump 96516597 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96516597/cr-3-1-a-a-a-e-hqqe.html

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR32-1-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 9612224 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612224/cr-32-1-2-a-f-a-e-hqqe.html

More information

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR45-5 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 9612285 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612285/cr-45-5-a-f-a-e-hqqe.html

More information

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ GRUNDFOS DATA BOOKLET CR5-26 A-FGJ-A-E-HQQE 3x4D 5HZ Grundfos Pump 96513391 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96513391/cr-5-26-a-fgj-a-e-hqqe.html

More information

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

CRN45-10 A-F-G-V-HQQV 3x400/ HZ GRUNDFOS DATA BOOKLET CRN45-1 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos Pump 9612316 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/9612316/crn-45-1-a-f-g-v-hqqv.html

More information

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz GRUNDFOS DATA BOOKLET CRN12-7 A-F-G-V-HBQV 75kW 3x4D 5Hz Grundfos Pump 9592225 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn12/9592225/crn-12-7-a-f-g-v-hbqv.html

More information

SF6. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS. Page - CONTENTS 100

SF6. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS. Page - CONTENTS 100 SPECIFICATIONS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHART 201 SELECTION CHART 202 SELECTION CHART 203 PERFORMANCE CHART R10 204 PERFORMANCE CHART R13 205 PERFORMANCE CHART S25 206 PERFORMANCE

More information

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz GRUNDFOS DATA BOOKLET CR1-4 A-A-A-E-HQQE 15kW 3x4Y 5Hz Grundfos Pump 965982 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/965982/cr-1-4-a-a-a-e-hqqe.html

More information

CRN A-F-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ GRUNDFOS DATA BOOKLET CRN64-7-2 A-F-G-V-HQQV 3x4/69 5 HZ Grundfos Pump 96123813 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn64/96123813/crn-64-7-2-a-f-g-v-hqqv.html

More information

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ GRUNDFOS DATA BOOKLET CR64-3-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96123531 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123531/cr-64-3-2-a-f-a-e-hqqe.html

More information

CR15-01 A-F-A-E-HQQE 3x230/ HZ

CR15-01 A-F-A-E-HQQE 3x230/ HZ GRUNDFOS DATA BOOKLET CR15-1 A-F-A-E-HQQE 3x23/4 5 HZ Grundfos pump 9651697 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9651697/cr-15-1-a-f-a-e-hqqe.html

More information

Stainless Steel Submersible Pumps DATA BOOKLET. ISO 9001 Company. 60 Hz. Pumping Solution

Stainless Steel Submersible Pumps DATA BOOKLET. ISO 9001 Company. 60 Hz. Pumping Solution Stainless Steel Submersible Pumps DATA BOOKET ISO 1 Company Pumping Solution Hz Photographs of a few Manufacturing Units Submersible Pumps Motors Hz 4 Submersible Pump Pumping Solution 11 Product data

More information

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

CR5-16 A-A-A-E-HQQE 3x400D 50HZ GRUNDFOS DATA BOOKLET CR5-16 A-A-A-E-HQQE 3x4D 5HZ Grundfos Pump 96513368 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96513368/cr-5-16-a-a-a-e-hqqe.html

More information

CRE20-08 A-F-A-E-HQQE 3x HZ

CRE20-08 A-F-A-E-HQQE 3x HZ GRUNDFOS DATA BOOKLET CRE2-8 A-F-A-E-HQQE 3x4 6 HZ Grundfos pump 96514642 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cre2/96514642/cre-2-8-a-f-a-e-hqqe.html

More information

Davey 4 Submersible Borehole Pumps and Motors 4 BOREHOLE PUMPS AND MOTORS APPLICATIONS. Model Numbers: J Series

Davey 4 Submersible Borehole Pumps and Motors 4 BOREHOLE PUMPS AND MOTORS APPLICATIONS. Model Numbers: J Series 4 BOREHOLE PUMPS AND MOTORS APPLICATIONS Domestic water supply Turf watering Irrigation Stock watering Dewatering Water treatment Why choose the davey 4 SUBMERSIBLE BOREHOLE PUMP? Proven and reliable design

More information

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-5 S-R-I-E-AQQE C-A-A-N GRUNDFOS DATA BOOKLET CM1-5 S-R-I-E-AQQE C-A-A-N Grundfos pump 98482158 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmsp0/98482158/cm1-5-s-r-i-e-aqqe.html

More information

CM1-3 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N GRUNDFOS DATA BOOKLET CM1-3 S-R-I-E-AQQE C-A-A-N Grundfos pump 98482156 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmsp0/98482156/cm1-3-s-r-i-e-aqqe.html

More information

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps OVIM/OVIMF A New Vision for Quality Pumps OVIM 60Hz OVIMF 60Hz Light Vertical Multistage Centrifugal Pumps PERFORMANCE SCOPE OVIM/OVIMF PRODUCT RANGE OVIM OVIM2 OVIM3 OVIM4 OVIM8 OVIM6 OVIM32 OVIM42 OVIM65