IROn PIPe. McWane DUcTILe
|
|
- Merryl Pitts
- 5 years ago
- Views:
Transcription
1 McWane DUcTILe IROn PIPe nsf 61 ISO 9001 DIPRa Boltless restrained joint systems Multiple design options available from 3 36 Fast and easy installation 350 pressure rating Independently tested
2 TyTOn and fastite PUSH-On joints Step 1. Thoroughly clean out the bell with special attention to the gasket recess. Remove any foreign material or excess paint. Clean the spigot or beveled plain end and remove any sharp edges with a standard file. After making sure that the correct gasket is being used, insert it into the recess in the bell with the small end of the gasket facing the bell face. Apply lubricant to the inside surface of the gasket, making sure that the entire surface is coated. Apply a generous coating of lubricant to the beveled portion of the plain end. Guide the plain end into the bell and, while maintaining straight alignment, push the plain end into the bell socket. Once the joint is assembled, necessary deflection can be accomplished. When assembly is complete, the bell face should be aligned between the two white depth rings, for Tyton Joints. Fastite Joints have only 1 assembly stripe. MecHanIcaL joint Step 1. Clean the bell socket and spigot or plain end. Lubricate both the gasket and plain end by brushing an approved pipe lubricant. Note: Place the gland on the plain end with the lip extension toward the plain end. Place the gasket on the plain end with the narrow edge facing the plain end. Insert the plain end into the bell and press the gasket into the bell recess. Push the gland toward the socket and center it around the pipe with the gland lip against the gasket. Insert and tighten the bolts. It is important to mainatain the same distance between the gland and the bell face at all times. This is best done by alternating side to side and top to bottom, while tightening the bolts. Achieving the recommended bolt torque, particularly with large diameter pipe, may require repeating the process up to 5 times or more. Recommended bolt torque ranges are as follows: Bolt Diameter nut across flats Wrench Length Torque Range foot Lbs. 3 5/8 1-1/ to /4 1-1/ to 90 nominal THIcKneSS for STanDaRD PReSSURe classes Of DUcTILe IROn PIPe Pressure class* Diameter normal in ** ** ** ** * Pressure Classes are defined as the rated water pressure of the pipe in. The thicknesses shown are adequate for the rated water working pressure plus a surge allowance of 100. Calculations are based on a minimum yield strength of 42,000 and a 2.0 safety factor times the sum of the working pressure and 100 surge allowance. **Calculated thicknesses for these sizes and pressure ratings are less than those shown above. Presently, these are the lowest nominal thicknesses available in these sizes. NOTE: Per ANSI/AWWA C150/A21.50 the thicknesses above include the 0.08 service allowance and the casting tolerance listed below by size ranges: SIZe (Inches) casting TOLeRanceS (Inches) TR flex ReSTRaIneD joint Step 1. (4 10 ) Lay pipe such that one of the bell slots is accessible. (12 20 ) Lay pipe such that both of the bell slots are accessible, in the horizontal position if possible. (24 36 ) Lay pipe such that all four of the bell slots are accessible, in the diagonal position if possible. Step 5. Step 6. Step 7. Step 8. Step 9. Step 10. Step 11. SUPeR-LOcK Step 1. Remove hook bolts securing retainer to plain end. Clean plain end of pipe. Clean out any dirt behind retainer lugs. Lubricant should be applied to the beveled nose. Step 5. Clean the bell socket and insert gasket. Clean the spigot end to the assembly stripes. Lubricate the exposed surface of the gasket and pipe spigot end back to the weld bead. Make a normal push-on joint assembly, completely homing the pipe until the first assembly strip is in the bell socket. Keeping the joint in straight alignment during the assembly process. (4 10 ) Insert the right-hand locking segment into a bell slot and slide the segment clockwise around the pipe. (12 36 ) Insert lower locking segment into a bell slot and slide the segment around the pipe. (4 10 ) Insert left-hand locking segment into the bell slot and slide the segment counterclockwise around the pipe. (12 36 ) Insert upper locking segment into the same bell slot and rotate around the pipe. (4 10 ) Hold the segments apart and wedge the rubber retainer into the slot between the two locking segments. (12 36 ) Hold the upper segment in place and wedge the rubbber retainer into the slot between the two locking segments. (4 10 ) None. (12 20 ) Repeat steps 6 8 for other slot. Make sure that all 4 locking segments and 2 rubber retainers are securely in place. (24 36 ) Repeat steps 6 8 for other slot. Make sure that all 8 locking segments and 4 rubber retainers are securely in place. Extend the joint to remove the slack in the locking segment cavity. Joint extension is necessary to attain the marked laying length on the pipe and to minimize growth or extension of the line as it is pressurized. Set the joint deflection as required. THRUST-LOcK ReSTRaIneD joint Step 1. Ring Installation. Put lock ring on the spigot end of the pipe. Pry the lock ring over the weldment. Use the hammer to tap the cover. Lock ring installation is complete. Step 5. Step 6. Step 7. Clean the Bell and Spigot. Thoroughly clean out the bell with special attention to the gasket recess. Remove any foreign material or excess paint. Clean the spigot end and remove any sharp edges. Insert the gasket into the recess in the bell with the small end of the gasket facing the bell face. Lubricate the Bell and Spigot. Apply lubricant to the inside surface of the gasket. Apply a generous coating of lubricant to the spigot end. Insert. Guide the spigot end into the bell and, while maintaining straight alignment, push the pipe into the bell socket. Insert Lock Ring. Push lock ring into the bell. Rotate the lock ring until the lugs align. Use a hammer to tap the ring if required. Install the anti-rotation wedges at 3 and 9 o clock if the pipe is being used inside of a casing. Deflect the joint if desired. Assemble the joint in accordance with Clow Assembly Instructions (See Table A on page 13). Make certain that the bell is clean prior to gasket insertion. Be sure that the correct gasket is used. Guide plain end into Super-Lock bell and provide reasonably straight alignment. Make joint by pushing the plain end into the bell. A jack or come-a-long may also be used to pull the plain end into the bell. Position retainer so that the recesses line up with the lugs on the bell. Slide retainer over bell and rotate until the lugs on the bell and the retainer line up. At drilled hole on retainer O.D., insert retainer lock in recess formed by lugs on bell and retainer. Insert roll pin in drilled hole and drive flush with retainer O.D. Take any necessary deflection after joint is completely assembled. caution: do not over deflect the joint beyond the maximum deflection column specified on page 2 or subject the joint to bending stress to obtain additional deflection.
3 TR flex ReSTRaIneD joint PIPe THRUST-LOcK BOLTLeSS ReSTRaIneD joint PIPe B A B A a B c PIPe C 4 24 C # of D.I. Locking Segments # of Rubber Segments Retainers Max Deflection Degrees Pullout / / / / / / *The TR FLEX Restrained Joint has a working pressure rating equivalent to the working pressure rating of the parent pipe with a maximum working pressure rating of 350 for 4 through 24 and 250 for 30 through 36. NOTE: These deflections are based on joints with nominal dimensions. SUPeR-LOcK ReSTRaIneD joint PIPe B 6 30 Degrees Deflection a B Inches in 18ft TyTOn joint PIPe s 6 24 fastite joint PIPe 30 O.D. Retainer O.D * In the 14 and larger sizes, pressure rating is limited to the rating of the pipe barrel thickness selected. Dimensions subject to manufacturing tolerances. A RaTeD WORKInG PReSSURe and MaXIMUM DePTH Of cover Thrust-Lock Boltless Restrained joint Degrees nominal Deflection a B c Inches in 18ft O.D. Bell O.D. Laying conditions Type 1 Type 2 Type 3 Type 4 Type 5 Trench Trench Trench Trench Trench Maximum depth of cover ft ** ** ** ** ** ** ** ** An allowance for a single H-20 truck with 1.5 impact factor is included for all depths of cover. Calculated maximum depth of cover exceeds 100 ft (30.5 m). ** Minimum allowable depth of cover is 3 ft (0.9 m). For pipe 14 in. (350 mm) and larger, consideration should be given to the use of laying conditions other than Type 1. Spigot Socket *The THRUST-LOCK Restrained Joint has a working pressure rating equivalent to the working pressure rating of the parent pipe with a maximum working pressure rating of 350 for 6 through 24 and 250 for 30. NOTE: These deflections are based on joints with nominal dimensions.
4 TyTOn and fastite joint PIPe MecHanIcaL joint PIPe Tyton joint Diameter *Dimensions from To a B *Nominal laying length is 18 ft. fastite joint *Dimensions Diameter from To a B *Nominal laying length is 18 ft. BaLL and SOcKeT joint PIPe a B full Length Weight - ** Safe end Pull class Retainer Under Water T as (a21.51) O.D. O.D. Shipped full of full of air Water , , , , , , B 15 Max * * * * * * required to overcome buoyancy. ** Weights listed are for 18 0 laying lenghts. Nominal full lengths vary by size., Bell, Ball and Retainer are ductile iron. Dimensions and weights are subject to manufacturing tolerances pressure rating: pressure rating: 250 T A 195, , , , ,000 STanDaRD DIMenSIOnS and WeIGHTS Of 3 THROUGH 36 PUSH-On joint DUcTILe IROn PIPe Pressure class Diameter from To B j K1 K2 no. nominal *Dimensions Bolts Bell Weight Length OD* Wt. of Barrel Per ft. Wt. of Bell Tyton joint Wt. Per Lgth. Gland** Bolts Gasket Weight / /4 3-1/ /4 3-1/ / / / /4 4-1/ /4 4-1/ /4 4-1/ /4 4-1/ / * Nominal laying length is 18 ft. ** Weight shown for regular grey cast iron follower gland, corton bolts, and rubber gasket. avg. Wt. Per ft ** ** Including bell; calculated weight of pipe rounded off to the nearest 5 lb. Including bell; average weight per foot, based on calculated weight of pipe before rounding. * Tolerances of OD of spigot end: 3 12 in. = in. & in. ; in. = in. & in. ; in. = in. & in. ** Fastite Joint
5 LayInG conditions Type 1* Flat-bottom trench. Loose backfill. Type 4 bedded in sand, gravel, or crushed stone to depth of 1/8 pipe diameter, 4 in. (100 mm) minimum. Backfill compacted to top of pipe. (Approximately 80 percent Standard Proctor, AASHTO T-99.) notes: Consideration of the pipe-zone embedment conditions included in this figure may be influenced by factors other than pipe strength. For additional information on pipe bedding and backfill, see ANSI/AWWA C600. Type 2 Flat-bottom trench. Backfill lightly consolidated to centerline of pipe. Type 5 bedded in compacted granular material to centerline of pipe. Compacted granular or select material++ to top of pipe. (Approximately 90 percent Standard Proctor, AASHTO T-99.) Type 3 bedded in 4 in. (100 mm) minimum of loose soil.++ Backfill lightly consolidated to top of pipe. * For 14 in. (355-mm) and larger pipe, consideration should be given to the use of laying conditions other than Type 1. Flat-bottom is defined as undisturbed earth. ++ Loose soil or select material is defined as native soil excavated from the trench, free of rocks, foreign materials, and frozen earth. American Association of State Highway and Transportation Officials, 444 N. Capitol St. N.W., Suite 225, Washington, DC STanDaRDS applicable TO DUcTILe IROn PIPe and fittings THIcKneSS DeSIGn Of DUcTILe IROn PIPe ANSI/AWWA C150/A21.50 DUcTILe IROn PIPe for WaTeR and OTHeR LIqUIDS ANSI/AWWA C151/A21.51 FEDERAL WWP421D, Grade C DUcTILe IROn PIPe for GRavITy flow SeRvIce ANSI/ASTM A746 DUcTILe IROn fittings for WaTeR and OTHeR LIqUIDS 3 through 36 ANSI/AWWA C110/A21.10 DUcTILe IROn compact fittings 3 through 24 ANSI/AWWA C153/A21.53 flanged fittings ANSI/AWWA C110/A21.10 ANSI B16.1 DUcTILe IROn PIPe WITH THReaDeD flanges ANSI/AWWA C115/21.15 coatings and LInInGS Asphaltic ANSI/AWWA C151/A21.51 ANSI/AWWA C110/A21.10 ANSI/AWWA C153/A21.53 Cement Lining ANSI/AWWA C104/A21.4 Various Epoxy Linings and Coatings MANUFACTURER S STANDARD Exterior Polyethylene Encasement ANSI/AWWA C105/A21.5 joints PIPe and fittings Push-On and Mechanical Rubber-Gasket Joints ANSI/AWWA C111/A21.11 FEDERAL WWP421D Flanged ANSI/AWWA C115/A21.15 ANSI B16.1 Grooved and Shouldered ANSI/AWWA C606 PIPe THReaDS ANSI B2.1 InSTaLLaTIOn ANSI/AWWA C600 atlantic STaTeS cast IROn PIPe co. 183 Sitgreaves St. Phillipsburg, NJ atlanticstates.com clow WaTeR SySTeMS company 2266 S. 6th St. Coshocton, OH clowwater.com nsf 61 PacIfIc STaTeS cast IROn PIPe co E 2000 S. Provo, UT pscipco.com ISO 9001 canada PIPe company ULc 1757 Burlington St. E Hamilton, ON L8N-3R canadapipe.com McWane cast IROn PIPe co Vanderbilt Road Birmingham, AL mcwanepipe.com DIPRa DIMenSIOn and WeIGHTS for SPecIaL classes Of PUSH-On joint and MecHanIcaL joint DUcTILe IROn PIPe nominal Wt. of Tyton joint OD* Barrel class Wt. of Wt. Per avg. Wt. Per ft. Bell Lgth. Per ft ** ** ** ** ** ** ** ** ** ** ** ** ** ** Including bell; calculated weight of pipe rounded off to the nearest 5lb. Including bell; average weight per foot, based on calculated weight of pipe before rounding. *Tolerances of OD of spigot end; 3 12 in. ±0.06 in., in in., in., in in., in. **Fastite Joint
6 SURe STOP GaSKeT for TyTOn joint Deflection Degrees SURE STOP 350 GASKETS are available in sizes 3 24, and with a rating of 350 they will meet or exceed the capabilities of ductile iron pipe, valves, and fittings. SURE STOP 350 GASKETS are NSF 61 approved, UL listed, and FM approved. FM : 4 6 = = 200 ApplicAtion notes 1. For ductile iron applications utilizing TYTON pipe, vales, and fittings made to AWWA specifications. 2. In cold weather assembly maintain the temperature of the gasket above 40 F. 3. The socket of the joint should be clean and free of debris or significant corrosion. 4. Gasket should be properly seated in the bell socket. 5. Keep the pipe and joint in alignment during assembly. If installed out of alignment, the gasket can be pushed out of position, creating the potential for leaks or failure. joint DefLecTIOn chart y-maximum joint Deflection in Degrees PUSH-On joint PIPe Maximum allowable joint Deflection X Deflection in Inches 18 ft. Length approximate Radius in ft. of curve Produced by Succession of joints 18 ft. Length MaXIMUM DefLecTIOn for full LenGTH PIPe 6. If deflection is wanted in the joint, deflect before fully inserting the joint. 7. Some extension of the joint will occur when pressurized. To avoid this, the joint should be pulled out after assembly to set the stainless steel teeth in the inserted pipe. 8. Once assembled, the joint can be disassembled using steel shims. 9. When cut pipe is used, the following steps are required: a. Ensure that the spigot end is properly beveled b. Mark the joint depth on the spigot so it is clear when the joint is fully inserted. c. Ensure that the pipe meets the required dimensional tolerances. 10. Do not reuse SURE STOP 350 GASKETS, as they may have been damaged during any previous installation or during removal. 11. Do not use SURE STOP 350 GASKETS to conduct electricity through the pipe joint, as they could be damaged and fail. 12. Do not use SURE STOP 350 GASKETS in above ground applications. 13. Do not use SURE STOP 350 GASKETS with thick coating on the pipe exterior. 14. If SURE STOP 350 GASKETS are used in straight casings, you must pull the pipe through the casing. Do not push the pipe. y-maximum joint Deflection in Degrees MecHanIcaL joint PIPe Maximum allowable joint Deflection X Deflection in Inches 18 ft. Length approximate Radius in ft. of curve Produced by Succession of joints 18 ft. Length field cut PIPe When pipe is cut in the field, the cut end may be readily conditioned so that it can be used to make up the next joint. The outside of the cut end should be beveled about 1/4 inch at an angle of about 30 degrees (Figure 1). This can be quite easily done with a coarse file or a portable grinder. The operation removes any sharp, rough edges which otherwise might damage the gasket. When ductile iron pipe 14 and larger is to be cut in the field, the material should be ordered as GAUGED FULL LENGTH. that is gauged full length is specially marked to avoid confusion. The ANSI/AWWA standard for ductile iron pipe requires factory gauging of the spigot end. Accordingly, pipe selected for field cutting should also be field gauged in the location of the cut and found to be within the tolerances shown in Table 1. In the field, a mechanical joint gland can be used as a gauging device. TaBLe 1: SUITaBLe PIPe DIaMeTeRS for field cuts and ReSTRaIneD joint field fabrication Min. Diameter Max. Diameter Min. circumference Max. circumference /4 12-5/ / / /2 21-7/ /4 28-5/ / / / / / / / / / / / / / / / /16 Above Table Based on ANSI/AWWA C151/A21.51 Guidelines for Push-On Joints. the BAcKHoe MetHoD of AsseMBlY A backhoe may be used to assemble pipe of intermediate and larger sizes. The plain end of the pipe should be carefully guided by hand into the bell of the previously assembled pipe. The bucket of the backhoe may then be used to push the pipe until fully seated. A timber header should be used between the pipe and backhoe bucket to avoid damage to the pipe.
866.DIP.PIPE P 1 NSF Edition. Certified to ANSI/NSF Edition 4" 36" REVISED 11.09
P 1 4" 36" For FIRE PROTECTION, Water & Wastewater P 2 Table of Contents TR FLEX Restrained Joint Pipe and Fittings 4"-36" 3 Suggested Specification Wording For 4"-36" Restrained Push-on Joint Pipe and
More informationP EDITION 4" 36" FOR FIRE PROTECTION, WATER & WASTEWATER REVISED 07.14
P 1 2014 EDITION 4" 36" FOR FIRE PROTECTION, WATER & WASTEWATER P 2 Table of Contents TR FLEX Restrained Joint Pipe and Fittings 4"-36" 3 Suggested Specification Wording For 4"-36" Restrained Push-on Joint
More informationTR Flex Pipe & Fittings DUCTILE IRON
TR Flex Pipe & Fittings DUCTILE IRON PIPE FABRICATION RESTRAINED JOINTS FITTINGS GASKETS COATINGS & LININGS CONTENTS GENERAL INFO Pipe 4" 36" 2 Suggested Specification Wording 3 ASSEMBLY INSTRUCTIONS Pipe
More informationFABRICATION TR Flex Pipe & Fittings DUCTILE IRON
PIPE FABRICATION TR Flex Pipe & Fittings DUCTILE IRON RESTRAINED JOINTS FITTINGS GASKETS COATINGS & LININGS CONTENTS GENERAL INFO Pipe 4" 36" 2 Suggested Specification Wording 3 ASSEMBLY INSTRUCTIONS Pipe
More informationFABRICATION TR Flex Pipe & Fittings DUCTILE IRON
PIPE FABRICATION TR Flex Pipe & Fittings DUCTILE IRON RESTRAINED JOINTS FITTINGS GASKETS COATINGS & LININGS CONTENTS GENERAL INFO Pipe " " Suggested Specification Wording ASSEMBLY INSTRUCTIONS Pipe & Fittings
More informationHP LOK Pipe & Fittings DUCTILE IRON
HP LOK Pipe & Fittings DUCTILE IRON PIPE FABRICATION RESTRAINED JOINTS FITTINGS GASKETS COATINGS & LININGS CONTENTS GENERAL INFO Pipe and Fittings 30" 64" 2 Suggested Specifications 3 ASSEMBLY INSTRUCTIONS
More informationRESTRAINED JOINT HP LOK 30" 64" RESTRAINED JOINT NSF WATER & WASTEWATER. Certified to ANSI/NSF 61
2 0 1 6 30" 64" E D I T I O N NSF WATER & WASTEWATER NSF P 2 Table of Contents Restrained Joint Pipe and Fittings 30" 64" 3 Suggested Specifications for Restrained Push-On Joint Pipe and Fittings 4 Joint
More informationPiranha Restraint Gasket
Document # 02-9-0005 07.23.2013 Piranha Restraint Gasket Joint Restraint for Tyton Ductile Iron Bell and Spigot Push-On Joints. occurred during transit and that no teeth are missing. Also check the diameter
More information2009 Edition. Tyton fittings 14"-24" NSF. For Water & Wastewater, Fire Protection & Industrial Applications. Certified to ANSI/NSF 61
14"-24" Tyton fittings For Water & Wastewater, Fire rotection & Industrial Applications 2 Table of Contents TYTON Fittings 3 Assembly of TYTON Fittings 4 Bell Dimensions 6 Thickness and Dimensions 90 Bends
More informationDUCTILE IRON PIPE DESIGN
4"-64" FOR FIRE ROTECTION, WATER & WASTEWATER 866.DI.IE 2 Table of Contents Ductile Iron ipe 3 Laying Conditions 5 Design Method and Examples of Selection Method 6 ressure Class 10 Thickness Class 11 Earth
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 836 GREY-IRON AND DUCTILE-IRON FITTINGS
ITEM NO. 836 GREY-IRON AND DUCTILE-IRON FITTINGS 836.1 DESCRIPTION: This item shall consist of grey-iron and ductile-iron fittings installation and adjustment installed in accordance with these specifications
More informationUNION-TITE DUCTILE IRON C153 COMPACT FITTINGS
Sizes 4"-12" UL Listed for Fire Main Equipment SAMPLE SPECIFICATIONS (Current ANSI/AWWA revisions apply) 4" through 24" Push-On joint ductile iron fittings shall be produced in accordance with all applicable
More informationSection 8 AMERICAN. Flanged Pipe
Section 8 AMERICAN Flanged Pipe The principal standards covering Flanged Pipe are ANSI/AWWA C115/A21.15 and ANSI/AWWA C110/A21.10. These and other standards are referenced throughout this Section either
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 836 GREY-IRON AND DUCTILE-IRON FITTINGS
ITEM NO. 836 GREY-IRON AND DUCTILE-IRON FITTINGS 836.1 DESCRIPTION: This item shall consist of grey-iron and ductile-iron fittings installation and adjustment installed in accordance with these specifications
More informationTABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44
TABLE OF CONTENTS Item Page Item Page ANSI/AWWA Compact & Full Body Pipe Fittings: Product Submittals and Installation: Mechanical & Flange Joint C153. 3-9 20U Protective Fusion Bonded Epoxy....5,5 Mechanical
More informationSECTION 5 AMERICAN. Ductile Iron Mechanical Joint Fittings
ECION 5 AMERICAN Ductile Iron Mechanical Joint Fittings he principal standards covering full body mechanical joint fittings are ANI/AWWA C110/A21.10 and ANI/AWWA C111/A21.11. Compact ductile iron fittings
More informationUtilities Catalog. PC-U2008, February, 2008
Utilities Catalog PC-U2008, February, 2008 Tyler Utilities 11910 CR. 492 Tyler, Texas 75706 (800) 527-8478 Union Foundry Company Box 309 Anniston, Alabama 3602 (800) 226-7601 TABLE OF CONTENTS Item Page
More informationTYLER UNION. Quality Waterworks Products. PC-2017, March, REGISTERED FIRMISO 9001:2015. Tyler Union
TYLER UNION Quality Waterworks Products WATERWORKS CATALOG PC-2017, March, 2017 www.tylerunion.com 10014257 U L REGISTERED FIRMISO 9001:2015 CERTIFIED Tyler Union 11910 CR 492 TYLER, TEXAS 75706 (800)
More informationPVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe
Joint Restraint Products PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe INFORMATION The PVC Stargrip Mechanical Joint Restraint System is a unique product with
More informationPVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe
PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe INFORMATION The PVC Stargrip Mechanical Joint Restraint System is an exceptional restraint system for mechanical
More informationData Sheet Issue A
General Description The Rapidrop Fig 601/602 dry barrel post / flushing fire hydrant is designed to be a trouble free, easy to maintain hydrant. The Fig 601/602 fire hydrant is rated for a working pressure
More informationOPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT
OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN-DARLING B-62-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation
More informationRated to the New, Higher Pressure Classes in Latest Editions of AWWA C900 and C909. Joint Restraint Products
Pipe Restrainers series 1000G2 1000G2C Restrainers for AWWA CI OD C900/C909 PVC/PVCO Pipe with MJ or Ductile Iron Push-On Fittings (Formerly Series 9000) INFORMATION Second Generation (Gen 2) PVC Restrainers
More informationVALVES, FIRE HYDRANTS, AND APPURTENANCES
VALVES, FIRE HYDRANTS, AND APPURTENANCES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Butterfly Valves B. Gate Valves C. Tapping Valve Assemblies D. Fire Hydrant Assemblies E. Flushing Devices (Blowoffs)
More informationWater, Sewer & Drain Fittings
Why Compact? Compact Joint are manufactured from a high strength, impact resistant ductile iron that offers a great margin of safety against service failures and provides vastly increased resistance to
More informationPRODUCT MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT
PRODUCT MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN - DARLING B-84-B-5 FIRE HYDRANT INTRODUCTION AND HISTORY... 1B-2 ORDERING Dimensions: Overall Hydrant... 1B-3 Optional Bases...1B-4
More information3"-42" FLANGE-TYTE II TM FULL FACE GASKET FOR FLANGED JOINTS 2016 EDITION FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS
TM FOR FLANGED JOINTS 3"-42" Certified to ANSI/NSF 61 FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS Table of Contents FULL FACE TM Gasket Introduction 3 Pressure Performance 3 Torque
More informationOPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT
OPERATION AND MAINTENANCE MANUAL 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT INDEX 5-1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE REPAIRS Operation
More informationDeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT
DeZURIK 20 144" BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT Instruction D10373 April 2017 Instructions These instructions provide information about the 20 (250 F2 model only) and the 24-144 BAW
More informationSuper Flange series 7200 Designed for use on Ductile Iron, Steel, PVC, PVCO and HDPE Pipes
Designed for use on Ductile Iron, Steel, PVC, PVCO and HDPE Pipes INFORMATION The Series 7200 Super Flange is a restrained flange adapter designed to connect plain end pipe to a flange end component. May
More informationStarFlex series 5000 Double-Ball Flexible Expansion Joint for the Protection of Water Wastewater, and Industrial Pipelines
Joint Restraint Products StarFlex series 5000 Double-Ball Flexible Expansion Joint for the Protection of Water Wastewater, and Industrial Pipelines INFORMATION StarFlex Flexible Expansion Joints can deflect
More informationOPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE
OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE INDEX SERIES 2500 DUCTILE IRON RESILIENT WEDGE GATE VALVE OPERATION and MAINTENANCE MANUAL. OPERATION AND MAINTENANCE Operation,
More informationCLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION
CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION TESTING AND DESIGN SPECIFICATIONS (PER AWWA C502 / NSF /ULC & FM) 1. Hydrant shall be manufactured in accordance with AWWA C502 latest revision
More informationSUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION WATER DISTRIBUTION VALVES
SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION 33 12 16 WATER DISTRIBUTION VALVES PART 1 GENERAL... 2 1.1 Description... 2 1.2 Reference Specifications, Codes, and
More informationDepth of Bury Tables 9B-5. A. General. B. Rigid Pipe Assumptions. Design Manual Chapter 9 - Utilities 9B - Trench Design
Design Manual Chapter 9 - Utilities 9B - Trench Design 9B-5 Depth of Bury Tables A. General The depth of bury tables on the following pages are based upon the design methodology from the various pipe material
More informationAmerican Flow control 5 1/4 B-62-B-5
American Flow control 5 1/4 B-62-B-5 Fire Hydrant FLOW CONTROL Construction Fully complies with AWWA C502 and is available UL Listed and FM Approved in applicable configurations. one-piece bronze OPERATING
More informationMEDALLION HYDRANT. clowvalve.com AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY
clowvalve.com MEDALLION HYDRANT AWWA C50 UL LISTED FM APPROVED NSF 6/37 CERTIFIED 50 PSI WORKING PRESSURE 0-YEAR LIMITED WARRANTY Clow Valve, A Division of McWane, Inc. MEDALLION HYDRANT FIRE PROTECTION
More informationFIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description
FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL Item No.s/Description Item No. Description Material Specification HYDRANT Qty. Req d Item No. Description Material Specification 1 Operating
More informationAmerican Flow control Series 2500
American Flow control 14-66 Series 2500 Resilient wedge gate valve FLOW CONTROL Construction Ductile iron operating nut Provides strength and durability. Lifting DEVICES 14-66 Valve is constructed of high-strength
More informationSWING CHECK VALVES SERIES 52-SC SERIES 600
SWING CHECK VALVES SERIES 52-SC SERIES 600 FEATURES/BENEFITS/SPECIFICATIONS AMERICAN Flow Control Series 52-SC Swing Check Valves incorporate design features to help increase service life for water and
More informationHeavy welded steel outlet half. 3/4-inch NPT test plug. Benefits
622 Tapping Sleeve Recessed cavity for mating to lip on standard tapping valves per MSS SP60. Heavy welded steel outlet half. 3/4-inch NPT test plug. Roll resistant, self-energizing concave wedge gasket.
More informationAMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT
AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and Approved by FM Approvals in applicable configurations. DUCTILE IRON
More informationC909 PVC Pipe Patent Pending
1113 - H Copyright 2011 EBAA Iron, Inc. All Rights Reserved 19MJ00 Mechanical Joint Restraint for 4 through 12 inch C909 PVC Restraints for C909 PVC Pipe Patent Pending Features and Applications: For use
More informationHP250II AND HP250 BUTTERFLY VALVES Engineering Creative Solutions for Fluid Systems Since 1901
H250II AND H250 BUTTERFLY VALVES Engineering Creative Solutions for Fluid Systems Since 1901 TABLE OF CONTENTS RATT H250II Scope of Line... 1 Design and Construction Details... 1 ipe Mating Chart... 1
More informationAmerican Flow control 5 1/4 b-84-b-5
American Flow control 5 1/4 b-84-b-5 Fire Hydrant FLOW CONTROL Construction Fully complies with AWWA C502 and is available UL Listed and FM Approved in applicable configurations. one-piece bronze OPERATING
More informationAMERICAN FLOW CONTROL 5 1/4 B-62-B-5 FIRE HYDRANT
AMERICAN FLOW CONTROL 5 1/4 B-62-B-5 FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and Approved by FM Approvals in applicable configurations. ONE-PIECE BRONZE
More informationAMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT
AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available Listed by Underwriters Laboratories, Inc. and Approved by FM Approvals in applicable configurations.
More informationFord Service Saddles and Tapping Sleeves
DQS Inc. Section AA 09/2017 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Ford Service Saddles and Tapping Sleeves Contents Recommended Product Application *Steel *C900/909*** Cast
More informationINFACT CORPORATION WATERWORKS PRODUCTS FLEX ADAPTOR SPECIFICATION S TOLL FREE:
INFACT CORPORATION WATERWORKS PRODUCTS SPECIFICATION S TOLL FREE: 888-773-9130 email: info@infactcorp.com www.infactcorp.com ENGINEERING DATA / PRODUCT CHECKLIST EASY-TO-INSTALL SPACE-SAVING RESTRAINT
More informationFIG Gruvlok Flanges
Gruvlok Flanges The Gruvlok Fig. 7012 Flange allows direct connection of Class 125 or Class 150 flanged components to a grooved piping system. The two interlocking halves of the 2" thru 12" sizes of the
More informationHYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).
TX420 & 425 240000299 & lower 4. Remove the LH side panel (Fig. 0388). Hydraulic Tandem Pump Removal Note: Cleanliness is a key factor in a successful repair of any hydraulic system. Thoroughly clean all
More informationPRODUCT MANUAL TRENCH ADAPTER
PRODUCT MANUAL TRENCH ADAPTER INDEX TRENCH ADAPTER PAGE INTRODUCTION... 8-2 FEATURES AND BENEFITS... 8-3 SPECIFICATIONS... 8-3 ORDERING Dimensions: Overall Dimensions and Weights... 8-4 Trench Depth and
More informationFord Bolted Flex Couplings. Section M. 5/2008; Web Revision 10/2010
Section M 5/2008; Web Revision 10/2010 Ford Bolted Flex Couplings The Ford Meter Box Company, Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260-563-3171 FAX: 800-826-3487
More informationTransmate. Installation & Operating Manual. Thank you for your purchase of the InsertaValve.
Installation & Operating Manual Thank you for your purchase of the InsertaValve. Please read and understand this operation manual. Our goal is to serve you, our customer. If you have any questions, complaints
More informationMUELLER. Centurion Series Fire Hydrant. Centurion Super Centurion 200 Super Centurion 250. Reliable Connections. Background and Forward 2
operating Instructions manual MUELLER table of contents PAGE Background and Forward 2 Centurion Series Fire Hydrant Centurion Super Centurion 200 Super Centurion 250 Handling and Inspection 3 Installation
More informationKENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York Telephone (607) Fax (607)
KENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York 14901 Telephone (607) 734-2211 Fax (607) 734-3288 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL General ECCENTRIC PLUG
More information5 1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT BY AMERICAN FLOW CONTROL
5 1/4 AMERICAN-DARLING B-84-B-5 FIRE HYDRANT BY AMERICAN FLOW CONTROL CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available UL Listed and FM Approved in applicable configurations. ONE-PIECE
More informationAVK SAUDI VALVES MANUFACTURING COMPANY
AVK SAUDI VALVES MANUFACTURING COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION
More informationINDEX WATEROUS 5 1/4 IN. PACER FIRE HYDRANT
INDEX WATEROUS 5 1/4 IN. PACER FIRE HYDRANT PAGE INTRODUCTION AND HISTORY............................................................. 2B 2 ORDERING Dimensions: Overall Hydrant...............................................................
More informationNOTE: Visit our website at for video repair procedures, under the Tools section.
Repair Instructions Hypro Repair Tools: Tool Box No. 3010-0168 1/4" Allen Wrench No. 3020-0008 Support Bars (2) No. 3010-0064 Port Brush No. 3010-0066 1/16" Allen Wrench No. 3020-0009 Brush Holder No.
More informationImportant: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks
TITAN pt. no.: 01 0000 0129 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
More informationImportant: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks
TITAN pt. no.: 01 0000 0119 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
More informationTrend Hydrants. Installation, Operation, Maintenance and Overhaul Instructions. Table of Contents. Illustrations. Tables H /16/10 12/04/95
Installation, Operation, Maintenance and Overhaul Instructions Form No. H-351 Date 12/04/95 Revision Date 02/16/10 Trend Hydrants New Style Trend Old Style Trend Model WB77 Wet Top Model WT77 Dry Top Model
More informationSentinel 250 Fire Hydrant
Maintenance Instructions manual table of contents PAGE Sentinel 250 Fire Hydrant Inspection and Lubrication 2 Rotating Hydrant to Face Desired Direction 3 Installing Extension Section 3-6 Restoring Service
More informationFLOWSERVE CORPORATION NOBLE ALLOY VALVE BALL VALVE REPAIR INSTRUCTION
FLOWSERVE CORPORATION NOBLE ALLOY VALVE BALL VALVE REPAIR INSTRUCTION Cookeville Valve Operation 1978 Foreman Drive Cookeville, TN 38541 PH: 800-251-6761 931-432-4021 FAX: 931-432-5518 CONTENTS FLOWSERVE/NOBLE
More informationFord Fabricated Steel Products
Ford Fabricated Steel Products Section N2 12/2000 The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487 Overseas
More informationKENNEDY VALVE RESILIENT WEDGE GATE VALVE MAINTENANCE MANUAL
KENNEDY VALVE Division of McWane, Inc. 1021 East Water Street P.O. Box 931 Elmira, New York 14902-0931 Telephone (607) 734-2211 Fax (607) 734-1003 KENNEDY VALVE RESILIENT WEDGE GATE VALVE MAINTENANCE MANUAL
More informationSteel Fabricated Coupling
Steel Fabricated Coupling Straight Connection IMPORTANT LINKS Click appropriate words to go to: Standard Limited Warranty Sales Terms & Conditions Freight Policy Returns Policy Corrosion & Product Selection
More informationFITTINGS AND FABRICATIONS DESIGNED AND ENGINEERED HIGH DENSITY POLYETHYLENE PIPE
Effective May 24, 2002 Cancels all previous publications U.S. Price $12.95 FITTINGS AND FABRICATIONS DESIGNED AND ENGINEERED FOR HIGH DENSITY POLYETHYLENE PIPE JCM Industries, Inc. P.O. Box 1220 Nash,
More informationAMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT
AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT CONSTRUCTION Fully complies with ANSI/AWWA C502 and is available Listed by Underwriters Laboratories Inc. and Approved by FM Approvals in applicable
More informationmechanical coupling system
mechanical coupling system R Since 1981 Depend-O-Lok has offered engineers, contractors, OEM s and system owners an improved pipeline coupling system. Depend-O-Lok products offer strength, longterm reliability,
More informationADMIRAL HYDRANT. clowvalve.com
clowvalve.com ADMIRAL HYDRANT AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 350 PSI WORKING PRESSURE AVAILABLE 10-YEAR LIMITED WARRANTY Clow Valve, A Division of McWane,
More informationPipe Repair Products. A complete selection for all types of pipe
Pipe Repair Products A complete selection for all types of pipe Mueller Service Saddles Manufactured and tested in accordance with ANSI/AWWA C800 & NSF 61 certified. Mueller service saddles, available
More informationAMERICAN AVK COMPANY AVK SERIES HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS
AMERICAN AVK COMPANY AVK SERIES 2700 - HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING
More informationDEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE
DEFENDER SERIES 5 Gallon, Double Walled, Field Replaceable Spill Container Model 705-550 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel:
More informationMcCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company
McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL The High Performance Company Table of Contents Safety Information - Definition of Terms... 1 Introduction... 1 Installation...
More informationSECTION 4 AMERICAN. Ductile Iron Fastite, Flex-Ring, and Lok-Ring Fittings
SECION 4 MEICN Ductile Iron Fastite, Flex-ing, and ok-ing Fittings MEICN Ductile Iron Fastite, Flex-ing, and ok-ing Fittings he principal standards covering fittings are NSI/WW C0/.0 and NSI/WW C53/.53.
More informationAMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS
AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING
More informationK81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS
GUARDIAN K81-DD FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J K M L N P Q S R
More informationProduct Manual PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF
WG Product Manual PS3900 / PS4600 / PS7000 / PS15000 / BF1600 / BF1900 / BF2600 / BF3800 1.330.274.8317 www.atlanticwatergardens.com Table of Contents Pond Volume... 2 Surface Area... 3 Streambed Construction...
More informationPIPE OUTSIDE DIAMETER GUIDE
June 7, 2018-1 PIPE OUTSIDE DIAMETER GUIDE PIPE OUTSIDE DIAMETER GUIDE - SMALL DIAMETER PIPE SIZES NOMINAL PIPE SIZES 1 /2" 3 /4" 1" 1 1 /4" 1 1 /2" 2" 2 1 /2" THIS O.D. GUIDE IS FOR YOUR CONVENIENCE &
More informationSPECIFICATIONS - DETAILED PROVISIONS Section Valve and Gate Operations CONTENTS
SPECIFICATIONS - DETAILED PROVISIONS Section 13446 - Valve and Gate Operations CONTENTS PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 SUBMITTALS... 1 1.04 QUALITY ASSURANCE... 1 1.05
More informationTAPPING DUCTILE IRON PIPE
TECHNICAL BULLETIN FOR WATER & WASTEWATER, FIRE PROTECTION P 2 Table of Contents Pipe Thickness Required for Different Tap Sizes 3 Tapping Test Details 5 Test Procedure 6 Observations and Comments 7 U.S.
More informationDESCRIPTION Acura TSX SUSPENSION Front - TSX. NOTE: For system description and component location, see Fig. 1.
2004 SUSPENSION Front - TSX DESCRIPTION NOTE: For system description and component location, see Fig. 1. Fig. 1: Identifying Front Suspension Components Wednesday, March 12, 2008 8:30:45 8:30:55 PM Page
More informationTYLER UNION IMPORT RESTRAINTS LP NR
SERIES 1000 MJ TUFGRIP WEDGE TYPE RESTRAINT FOR DUCTILE IRON PIPE MJ TUFGRIP for DI Pipe - GLAND ONLY N70-5760 MJ TUFGRIP for DI Pipe - W/ ACCESSORIES N71-6795 3 113805 $42.94 7 150 3 114352 $65.05 10
More informationK81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS
GUARDIAN K81-D FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J L M K N P Q S R
More informationINDEX WATEROUS 5-1/4 IN. PACER FIRE HYDRANT
INDEX WATEROUS 5-1/4 IN. PACER FIRE HYDRANT PAGE INTRODUCTION AND HISTORY.............................................................. 2B-2 ORDERING Dimensions: Overall Hydrant...............................................................
More informationJCM 101 Universal Clamp Couplings
JCM 1 Universal Clamp Couplings JCM 1 Universal Clamp Coupling - Single Band JCM Universal Clamp Couplings provide a full circumferential seal and wide range for the permanent repair or reconnection of
More informationAMERICAN FLOW CONTROL 4"-48" SERIES 2500 TAPPING VALVES
AMERICAN FLOW CONTROL 4"-48" SERIES 2500 TAPPING VALVES FEATURES/SPECIFICATIONS/MAINTENANCE FEATURES AMERICAN provides tapping valves for sizes 4 in. 48 in. rated at 250 psig pressure. Tapping valves 4
More informationSeptember 2012 / M&H C502 / Model 129
GENERAL FEATURES / GENERAL SPEC M&H AWWA C502 FIRE HYDRANTS Model 129 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approved Type: Compression type, opening against line
More informationCam-Lock 111, 120 Joint Restraints Patent Pending
111, 120 Joint Restraints The Next Generation Joint Restraint Technology Smith-Blair Cam-Lock joint restraint products provide a fast and economical means restraining mechanical joint water and wastewater
More information3.2 DRIVE TORQUE HUB. Roll, Leak and Brake Testing SECTION 3 - CHASSIS & TURNTABLE. 3-2 JLG Lift
3.2 DRIVE TORQUE HUB Roll, Leak and Brake Testing 10 LUG PATTERN Torque-Hub units should always be roll and leak tested before disassembly and after assembly to make sure that the unit's gears, bearings
More informationCompy Model: HPL-1 Instructions
Compy Model: HPL-1 Instructions Installation Standard kit includes materials needed to convert one side of a typical boat or utility trailer axle spindle(s) up to three axle spindles per side can be manifolded
More informationGENERAL FEATURES / SPEC M&H AWWA C502 FIRE HYDRANTS Style 929 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approval Type: Compression type, opening against line pressure.
More informationSeries Roll Seal
INSTALLATION / OPERATION / MAINTENANCE SERIES 00-4 700 Series Roll Seal DESCRIPTION The Cla-Val Model 00-4 Roll Seal valve is a hydraulically operated valve used to control liquid flow by means of a flexible
More informationStyle 234 Restrained Flexible Single-Gasket Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date
Victaulic Bolted Split-Sleeve Products (VBSP) Style 234 carbon steel couplings (formerly Depend-O-Lok Air/FluidMaster) are single-arch couplings that are commonly used in buried or exposed steel pipe applications
More informationI-795/906. Series 795 and 906 Installation-Ready Knife Gate Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS
INSTALLATION AND MAINTENANCE INSTRUCTIONS I-795/906 Series 795 and 906 Installation-Ready Knife Gate Valves HANDWHEEL OPERATOR PNEUMATIC OPERATOR HYDRAULIC OPERATOR WARNING Read and understand all instructions
More informationFord Service Saddles and Tapping Sleeves
Section AA 04/2013; web revision 02/2014 Ford Service Saddles and Tapping Sleeves The Ford Meter Box Company, Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260-563-3171
More informationHole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole
Mechanical Tees Hole-cutting Shurjoint mechanical tees provide a fast and easy mid-point branch outlet, eliminating the need for welding or the use of multiple fittings. The Model M21 features a female
More informationRING FLANGE-TYTE Gasket
4"-36" FOR FLANGED JOINTS FOR WATER & WASTEWATER, FIRE ROTECTION & INDUSTRIAL ALICATIONS A Forterra Company 866.DI.IE 2 Table of Contents Introduction 3 ressure erformance 3 Torque erformance 3 Compatibility
More information