1
2 2
3 Grooved Piping Products Tyco Fire Products is ISO 9001 Certified with products manufactured in our newly constructed state of the art domestic ductile iron foundry and manufacturing facilities. We are committed to maintaining our leadership role in the grooved piping industry through aggressive research and development. The products that will improve our industry tomorrow are being designed today. With this level of investment and commitment, Tyco Fire Products is prepared to become the industry standard. Tyco Fire Products is a world leader in the manufacture and distribution of piping products. Years of development, engineering, pattern and tooling manufacturing, and the acquisition of the necessary resources has provided the finest grooved products available on the market today. Grooved Piping Products are domestically manufactured to scrutinizing quality standards as set forth by independent testing laboratories. Our Technical and Engineering Services, located in Bethlehem, PA, direct product development from concept through design, testing and manufacturing, then forwards all aspects of application engineering and quality assurance. Owners, architects, consulting engineers, contractors, and tenants demand the most dependable, quality grooved products for their piping systems - the Bethlehem Engineering facility ensures their demands are met each and every time. General Notes: It is the Designer s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions. Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. 3
4 Table of Contents General Information System Design Groove Specifications Roll Groove Cut Groove Gaskets Installation Instructions General Notes; Care and Maintenence Grooved Couplings Figures 572 and 772 Rigid Couplings Figure 575, 705 and 707 Flexible Couplings Figure 716 Reducing Coupling Mechanical Outlets Figure 730 Mechanical Tee and Cross Figure 40-5 Strap Flange Adapter Figure 71 Flange Adapter Butterfly Valves Figures 570 and Supervisory Switch Replacement Check Valves Figures 590F and 590FR Maintenance Kit Table of Contents
5 Table of Contents Grooved Fittings ADACAP Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Unit Conversions and Sprinkler Formulae Terms and Conditions of Sale Product Index Table of Contents 5
6 METALLURGICAL SPECIFICATIONS Grooved Piping Products are domestically manufactured in our state of the art ductile iron foundry. The applicable material specifications for ductile iron, galvanizing and rubber-injection apply. HOUSING / FITTING SPECIFICATIONS ASTM A (Cast Products) Standard Specification for Ductile Iron Castings Grade , Tensile Strength, minimum psi: 65,000 Yield Strength, minimum psi: 45,000 Elongated in 2" or 50mm, minimum 12% ASTM A53 - Schedule 40 Steel Pipe - Series fittings ASTM A Standard Specification for Hot Dip Galvanizing GASKET SPECIFICATIONS (Refer to Gasket Recommendation Tables - No and ) Gaskets: Grade E EPDM with green color code identification conforms to ASTM D-2000 for service temperature from -30 F (-34 C) to 230 F (110 C). They are recommended for hot water not to exceed 230 F (110 C), plus a variety of dilute acids, oil free air and many chemical services. They are not recommended for petroleum services. Gaskets (fire protection): Grade A EPDMA with violet color code identification conforms to ASTM D2000 for fire protection services. For dry pipe and freezer systems use Tri-Seal Grade E Gaskets with rigid couplings. Gaskets: Grade T Nitrile with orange color code identification conforms to ASTM D2000 for petroleum products. Not recommended for hot water systems. BOLT / NUT SPECIFICATIONS Bolts and Nuts: Coupling bolts and nuts are heat treated carbon steel, oval-neck track head bolts and heavy hex nuts, conforming to ASTM A-183 minimum tensile strength of 110,000 psi. Bolts and nuts are Zinc electroplated. PAINT SPECIFICATIONS Orange - non lead (standard) Fire Brigade Red - non lead (optional) 6 General Information
7 ISO 9001 CERTIFIED Tyco Fire Products is ISO 9001 Certified confirming conformance to quality standards of our products. Factory Mutual Research Corporation CERTIFICATE OF REGISTRATION FMRC certifies herewith that TYCO FIRE PRODUCTS 1550 Valley Center Parkway, Suite 135 Bethlehem, PA has demonstrated a Quality Assurance System that complies with the requirements of ISO 9001 Scope: DESIGN AND MANUFACTURE OF CASTINGS, PIPE COUPLINGS, FITTINGS, VALVES, AND RELATED PIPING SYSTEM PRODUCTS Registration No. Expiration Date June 30, 2002 This registration is subject to ongoing audits by FMRC. Any change to the basis of this registration requires acceptance in writing by FMRC. August 31, 2000 R.L. Martell, Asst. Vice President Date QUALITY SYSTEM FMRC REGISTRATION RvA The Dutch Council for Accreditation General Information 7
8 GOVERNMENT AGENCIES Coast Guard - Approved each vessel individually Corps of Engineers (COE) - GEGS Federal Aviation Administration (FAA) - HVAC, Plumbing and Fire Protection Federal Housing Administration (FHA) General Services Administration (GSA) Series Military Specifications (MIL) - MILP Fittings; MIL - C Couplings; MIL - P A (CE) Steel Pipe, Grooved MIL - I Inspection Procedure National Aeronautics and Space Administration (NASA) Naval Facilities Engineering Command (NAVFAC)- NFGS Series National Institute of Health (NIH) - Dept. of Health Series Veterans Affairs (VA) Series GENERAL CODE GROUPS, ASSOCIATIONS, LABORATORIES AND APPROVAL BODIES American Bureau of Shipping (ABS) American National Standards Institute / American Water Works Association (ANSI / AWWA) American Petroleum Institute (API) - API Std. 5L, Sect. 7.5 American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) American Society of Mechanical Engineers (ASME) Power Piping, B-31.1; Chemical Plant and Petroleum Refinery Piping, B-31.3; Refrigeration Piping, B-31.5; Building Services Piping, B Building Officials and Code Administrators (BOCA) Factory Mutual Engineering Corp. (FM) - Approved for Fire Protection Services Material Equipment and Acceptance (MEA) National Fire Protection Association (NFPA) New York Board of Standards and Appeals (NY-BSA) Southern Building Code Congress International (SBCCI) - Standard Plumbing Underwriter s Laboratories, Inc. (UL) - Listed for Fire Protection Services Underwriters Laboratories of Canada (ULC) - Listed for Fire Protection Services FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. 8 General Information
9 Grooved Piping Products provide several design and economic advantages when compared to welded or flanged systems. Field modifications are easily accommodated with the Grooved System as couplings and fittings can be easily rotated, eliminated and/or added to facilitate the necessary modification. ECONOMICAL Grooved couplings are the fastest method to join steel pipe. There is no need for two holing with flanges, and the potential of fire hazards is eliminated when compared to welding or brazing. RETROFIT The Grooved System method allows for quick economical changes as necessary for field retrofit, with the ability to isolate equipment and piping systems for tenant changes and system repair. Rigidity Figure 572 and 772 Rigid Grooved Couplings are ideally suited for valve and fitting connections, long runs, and risers where pipe movement is undesirable. Rigid couplings provide for joints which are comparable to pipe jointing such as welding and flanging. ALIGNMENT Every grooved coupling is a union which provides easy access for maintenance or piping system modification. Field modification can be handled easily with minimal effort due to the interchangeability of the grooved method. DEPENDABILITY The coupling housing are designed to engage into the grooves and provide a secure joint. The pipe ends are sealed by a pressure responsive gaskets which is encapsulated by the ductile iron housing. FLEXIBILITY Figure 575 and 705 Flexible Grooved Couplings allow for deflection of the piping system. General Information 9
10 Decimal Equivalents of Fractions (inches) 1 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / General Information
11 Bolt / Socket Sizes Size Bolt Socket Bolt Socket Bolt Socket Bolt Socket Size Size Size Size Size Size Size Size 1 1 4" 3 8" 11 16" 3 8" 11 16" 1 1 2" 3 8" 11 16" 3 8" 11 16" 1 2" 7 8" 2" 3 8" 11 16" 3 8" 11 16" 1 2" 7 8" 5 8" " 2 1 2" 3 8" 11 16" 3 8" 11 16" 1 2" 7 8" 5 8" " 76.1mm M10 16mm M12 18mm M12 18mm 3" 3 8" 11 16" 1 2" 7 8" 1 2" 7 8" 5 8" " 4" 3 8" 11 16" 1 2" 7 8" 5 8" " 5 8" " 5" 5 8" " 5 8" " 3 4" 1 1 4" 3 4" 1 1 4" 165.1mm M16 24mm M16 24mm M20 30mm 6" 5 8" " 5 8" " 3 4" 1 1 4" 3 4" 1 1 4" 8" 3 4" 1 1 4" 3 4" 1 1 4" 7 8" " 3 4" 1 1 4" 10" 1" 1 5 8" 1" 1 5 8" 1" 1 5 8" 7 8" " 12" 1" 1 5 8" 1" 1 5 8" 1" 1 5 8" 7 8" " & Size Bolt Socket Bolt Socket Bolt Socket Size Size Size Size Size Size 1 1 4" 3 8" 9 16" 3 8" 11 16" 1 1 2" 3 8" 9 16" 3 8" 11 16" 2" 3 8" 9 16" 3 8" 11 16" 3 8" 11 16" 2 1 2" 3 8" 9 16" 3 8" 11 16" 3 8" 11 16" 3" 3 8" 11 16" 1 2" 7 8" 4" 3 8" 11 16" 1 2" 7 8" 5" 5 8" " 6" 1 2" 7 8" 5 8" " 8" 5 8" " 3 4" 1 1 4" 716 Size Bolt Socket Size Size 2" x 1 1 2" 3 8" 11 16" 2 1 2" x 2" 3 8" 11 16" 3" x 2" 1 2" 7 8" 3" x 2 1 2" 1 2" 7 8" 4" x 2" 5 8" " 4" x 2 1 2" 5 8" " 4" x 3" 5 8" " 5" x 4" 3 4" 1 1 4" 6" x 4" 3 4" 1 1 4" 6" x 5" 3 4" 1 1 4" 8" x 6" 7 8" " Note: See Installation Instructions Section for bolt torques. General Information 11
12 System Design Grooved Piping Products provide the versatility required in piping systems through the use of rigid and flexible piping products. Figure 572 and 575 Couplings incorporate rotation resistant gripping teeth which provide the installer and designer with increased benefits. Rigid Joints Rigid Couplings provide rigid gripping of the pipe. They are designed to bring the pipe ends closely together and the coupling clamps firmly onto the pipe OD and also into the bottom of the grooves. Because Rigid Couplings clamp around the entire pipe surface, they provide resistance to flexural loads and therefore permit longer spacing to ASME/ ANSI B31.1 (Power Piping) and ASME/ANSI B39.1 (Building Services) requirements as well as NFPA 13 (Sprinkler Systems). Flexible Joints Flexible Couplings act as an "expansion joint", allowing linear and angular movement of the pipe. They are designed with the coupling keys engaging the pipe without gripping on the bottom of the grooves, while still providing for a restrained mechanical joint. This is particularly useful to allow for pipe expansion or contraction and piping misalignment. 12 System Design
13 Pipe Hanger Spacing All piping systems require that the support system accommodate the weight of the pipe, joint connections, fluid and other system components. In general, the requirements of NFPA 13 govern sprinkler system design. Nominal Suggested Max. Span Size Between Supports Inches Feet mm Meters / / / mm Spacing by NFPA 13 Sprinkler Systems (Steel Pipe except Threaded Lightwall) Nominal Suggested Max. Span Size Between Supports Inches Feet mm Meters mm System Design 13
14 Standard Specifications Roll Groove A B T OD C D 1. The maximum allowable tolerances for IPS pipe from square cut ends is 0.030" (0.76mm) for sizes 1 1 4" thru 3"; 0.045" (1.14mm) for sizes 4" thru 6"; and 0.060" (1.52mm) for sizes 8" and above. 2. Gasket Seating Surface "A" must be free from score marks, ridges, indentations, projections, loose paint, scale, dirt chips, grease, rust, etc. that would prevent a positive seal. 3. Groove diameter "C" must be of uniform depth around the circumference of the pipe. 4. Groove Depth "D" is a reference dimension only. The Groove Diameter "C" must be maintained. 5. Minimum Wall Thickness "T" is the minimum wall thickness that should be roll grooved. 6. Maximum allowable pipe end flare diameter is measured at the pipe end diameter. Pipe O.D. Nom Inches Pipe mm Size Tolerance O.D /4" /2" " /2" mm " " " mm " " " " Groove Specifications
15 Standard Specifications Roll Groove (cont.) A B T OD C D A B C D T Maximum Nom ± 0.030" ± 0.030" Groove Dia. Groove Minimum Allow. Flare Pipe ±0.76mm ±0.76mm Inches Depth Wall Diameter Size Inches Inches mm Inches Inches Inches mm mm Actual Tol.+ 0 mm mm mm 1 1 /4" 1 1 /2" 2" 2 1 /2" 76.1mm 3" 4" 5" 165.1mm 6" 8" 10" 12" Groove Specifications 15
16 Standard Specifications Cut Groove A B T OD C D 1. The maximum allowable tolerances for IPS pipe from square cut ends is 0.030" (0.76mm) for sizes 1 1 4" thru 3"; 0.045" (1.14mm) for sizes 4" through 6"; and in. (1.52mm) for sizes 8" and above. 2. Gasket Seating Surface "A" must be free from score marks, ridges, indentations, projections, loose paint, scale, dirt chips, grease, rust, etc. that would prevent a positive seal. 3. Groove diameter "C" must be of uniform depth around the circumference of the pipe. 4. Groove Depth "D" is a reference dimension only. The Groove Diameter "C" must be maintained. 5. Minimum Wall Thickness "T" is the minimum wall thickness that should be cut grooved. Nom Pipe Size 1 1 /4" 1 1 /2" 2" 2 1 /2" 76.1mm 3" 4" 5" 165.1mm 6" 8" 10" 12" Pipe O.D. Inches mm O.D. Tolerance Groove Specifications
17 Standard Specifications Cut Groove (cont.) A B T OD C D A B C D T Nom ± 0.030" ± 0.030" Groove Dia. Groove Minimum Pipe ±0.76mm ±0.76mm Inches Depth Wall Size Inches Inches mm Inches Inches mm mm Actual Tol.+ 0 mm mm 1 1 /4" /2" " /2" mm " " " mm " " " " Groove Specifications 17
18 Gaskets (Refer to Gasket Recommendations No and for specific application recommendations) Grade Temp. Color Compound Range Code General Service Application Ambient Fire Protection Systems. Not A to Recommended for Hot Water Systems EPDMA Violet +150 F For dry pipe or freezer systems, (+66 C) use Tri-Seal Grade E Gasket. -30 F Hot Water, dilute acids, alkalies, and (-34 C) many chemical services not involving E to EPDM Green petroleum products. Excellent +230 F oxidation resistance. NOT FOR USE (+110 C) WITH HYDROCARBONS. -20 F Petroleum products, vegetable oils, (-29 C) and air with oils. Not recommended T to Nitrile Orange for Hot Water Systems. Not +180 F recommended for Hot Dry Air over (+82 C) +140 F (+60 C) Note: Dry pipe and freezer systems are unique applications which benefit from proper pipe preparation and the use of rigid couplings, such as our Figures 572 and 772 couplings and our Tri-Seal gaskets. Reducing couplings are not recommended for these applications. Standard lube is not recommended for this application as it freezes and can cause leakage. Proper pipe end preparation and grooving is mandatory to prevent leakage (See specifications for cut and roll grooving). The gasket seat surface must be free from score marks, ridges, indentations, projections, loose paint, flaking galvanizing, scale, dirt chips, grease, rust, etc. that would prevent a positive seal. The best choice for a trouble free system is to use our rigid couplings with our Tri-Seal gaskets and a petroleum free silicone base lubricant. Prelubricated gaskets do not require the use of silicone lubricant. 18 Gaskets
19 Tri-Seal Freezer Gasket The Tri-Seal Grade E freezer gasket is used primarily for dry pipe fire protection systems, vacuum service, and freezer applications. The Tri-Seal freezer gasket differs from standard gaskets by closing off the gap or gasket cavity. This is accomplished by positioning the center rib of the gasket over the gap between the pipes. The Tri-Seal freezer gasket has two tapered sealing edges in addition to the center rib for additional strength and sealing. The Tri-Seal freezer gasket is available in sizes 1 1 /4" to 12" and is designed for use with Figure 575, 572, 705, 707 and 772 Couplings. A petroleum-free silicone based lubricant is recommended for dry pipe systems. For low temperature services or dry systems in cold storage or freezer applications, use Tri-Seal freezer gaskets. For vacuum services greater than 10" Hg, Tri-Seal gaskets should be used. Note: Rigid couplings are preferred for vacuum, dry pipe and freezer applications. Pre-Lubricated Gasket Pre-lubricated gaskets are provided with a propritary coating which eliminates the need for the installer to apply a lubricant during the assembly process. They are available in both the Grade A EPDM or Tri-Seal Grade E EPDM styles. TM Lube Gaskets 19
20 Installation Instructions General Notes: It is the Designer s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions. Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. 20 Installation Instructions
21 Figure Patented B C A Pipe Max. * Max. Max. O.D. End Gap Pressure End Load Size Inches Inches psi Lbs. mm mm kpa N 1 1 4" 1 1 2" 2" 2 1 2" 3" 4" 6" 8" ,328 1,947 2,885 4,769 10,336 17, ,887 3,781 5,907 8,660 12,832 21,213 45,975 77,925 FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. * Maximum available gap between pipe ends. Minimum gap = 0 Maximum pressure and end load are based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Protection for details. See Fire Protection Submittal Sheet for Listing and Approval pressure ratings. Dimensions Bolt Net Pipe A B C Bolt Torque Wt. Size Inches Inches Inches Size Lbs.-Ft. Lbs. mm mm mm Dia. x Lg. Nm Kg " " x 2 1 4" " " x 2 1 4" " " x 2 1 4" " " x 2 1 4" " " x 2 1 4" " " x 2 1 4" " " x 3" " " x 3" Installation Instructions Figure 572 and 772 Couplings 21
22 Figure 772 patented B C A Pipe Max. * Max. Max. O.D. End Gap Pressure End Load Size Inches Inches psi Lbs. mm mm kpa N 1 1 4" 1 1 2" 2" 2 1 2" 76.1mm 3" 4" 5" 165.1mm 6" 8" 10" 12" ,417 2,214 3,244 2,120 4,808 7,948 7,288 9,950 13,782 26,278 22,679 31, ,447 3,447 3,447 3,447 3,447 2,758 3,103 1,724 1,724 2,887 6,303 9,848 14,430 9,430 21,387 35,353 32,417 44,258 61, , , ,905 * Maximum available gap between pipe ends. Minimum gap = 0 Maximum pressure and end load are based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Protection for details. See Fire Protection Submittal Sheet for Listing and Approval pressure ratings. 22 Installation Instructions Figure 572 and 772 Couplings
23 Figure 772 (Continued) patented FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. Dimensions Bolt Net Bolt Pipe A B C Torque Wt. Size** Size Inches Inches Inches Lbs.-Ft. Lbs. Dia. x Lg. mm mm mm Nm Kg " 3 8" x " " 3 8" x " " 3 8" x " " 3 8" x " mm M10 x " 3 8" x " " 3 8" x " " 5 8" x " mm M16 x " 5 8" x " " 3 4" x " " 1" x " " 1" x " ** - Metric bolt size used on 76.1mm and 165.1mm couplings. Installation Instructions Figure 572 and 772 Couplings 23
24 Figure 572 and 772 Rigid Coupling patented Always read and understand the instructions. Never remove any piping component without verifying that the system is depressurized and drained. Rigid Couplings with Tri-Seal gaskets are preferred for dry pipe and freezer applications. Installation / Assembly Instructions The following instructions apply to Figure 572 and 772 Rigid Couplings. The installation is based on pipe grooved in accordance with Standard Cut Groove or Roll Groove Specifications. Step 1. Inspect exterior groove and ends of the pipe to verify all loose debris, dirt, chips, paint and any other foreign material such as grease are removed. Pipe ends sealing surfaces must be free from projections, indentations, or other markings. Step 2. Verify that the coupling and gasket grade are correct for the application intended. Plese refer to Gasket Grades and Gasket Recommendations Literature for additional information. The edges and outer surfaces of the gasket should be covered with a fine layer of petroleumfree silicone lubricant or equivalent. Petroleum lubricant should not be used on Grade E EPDM or Grade A EPDMA gaskets to prevent deterioration of the gasket material. Tri-seal gaskets are recommended for freezer applications. Note: Silicone lubricant must be used in Dry Pipe and Freezer Applications. (Pre-lubricated gaskets do not require silicone libricant.) Step 3. Install the gasket by placing the gasket over the pipe, which is to be fastened by the rigid coupling and ensure that the gasket lip does not extend beyond the end of the pipe. Step 4. Bring both pipe ends together, ensure proper alignment and slide the gasket into position, properly centering it between the grooved portions of each pipe. Note: the gasket should not protrude into the grooves on either pipe segments or extend between the pipe ends. 24 Installation Instructions Figure 572 and 772 Couplings
25 Figure 572 and 772 Rigid Coupling (Cont.) patented Step 5. With one nut and bolt removed, swing around as shown. Verify that the housings are over the gasket and that the housing keys are fully engaged into the grooves. Note: Sizes 1 1 4" - 12" Figure 772 and Figure 572 utilize a tongue and recess arrangement, which must be mated properly for the coupling to function according to design. These pictures show the patented Universal Tongue and Recess arrangement. These coupling housings have identical tongue/ recess pairs at each end, which allow an engagement fit no matter which end of the housing is brought together. Step 6. Insert the other bolt into the coupling and rotate the nuts until finger tight. Verify that the bolt heads are fully recessed in the housing. Step 7. Alternate between bolts when tightening nuts until properly torqued as shown in the table. Note: uneven tightening can cause the gasket to pinch or bind. Note that on the 1 1 4" - 8" Figure 572 and 1 1 4" - 12" 772 couplings there is an intended gap of up to 1/16 of an inch at each pad to allow for positive rigid gripping onto the pipe. Installation Instructions Figure 572 and 772 Couplings 25
26 Figure Patent Pending B C FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. A Pipe Max. * Max. Max. Deflection O.D. End Gap Pressure End Load Size Inches Inches psi Lbs. Per Inches/Foot mm mm kpa N Coupling mm/m 1 1 4" 1 1 2" 2" 2 1 2" 3" 4" 6" 8" ' , ' , , ' , , ' , , ' , , ' , , ' , , ' , * Maximum available gap between pipe ends. Minimum gap = 0 Maximum pressure and end load are based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Protection for details. Dimensions Bolt Net Pipe A B C Bolt Torque Wt. Size Inches Inches Inches Size Lbs.-Ft. Lbs. mm mm mm Dia. x Lg. Nm Kg " " x 2 1 4" " 2" 2 1 2" " x 2 1 4" " x 2 1 4" " x 2 1 4" " " x 2 1 4" " 6" 8" " x 2 1 4" " x 3" " x 3" Installation Instructions Figure 575, 705 and 707 Couplings
27 Figure 705 B C A Pipe Max. * Max. Max. Deflection O.D. End Gap Pressure End Load Inches/ Size Inches Inches psi Lbs. Per Foot mm mm kpa N Coupling mm/m 1 1 4" ' , " ' , " , ' , " , ' , mm , ' , " , ' , " , ' , " , ' , mm , ' , " , ' , " , ' , " , ' , , " , ' , , * Maximum available gap between pipe ends. Minimum gap = 0 Maximum pressure and end load are based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Protection for details. See Fire Protection Submittal Sheet for Listing and Approval pressure ratings. Installation Instructions Figure 575, 705 and 707 Couplings 27
28 Figure 705 (cont.) FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. Dimensions Bolt Net Bolt Pipe A B C Torque Wt. Size** Size Inches Inches Inches Lbs.-Ft. Lbs. Dia. x Lg. mm mm mm Nm Kg " 3 8" x 2 1 4" " 3 8" x 2 1 4" " 3 8" x 2 1 4" " 3 8" x 2 1 4" mm M10 x " 1 2" x 3" " 1 2" x 3" " 5 8" x 3 1 4" mm M16 x " 5 8" x 3 1 4" " 3 4" x 4 3 4" " 1" x 6 1 2" " 1" x 6 1 2" ** Metric Bolts used for 76.1mm and 165.1mm couplings. 28 Installation Instructions Figure 575, 705 and 707 Couplings
29 Figure 707 B C A Pipe Max. * Max. Max. Deflection O.D. End Gap Pressure End Load Size Inches Inches psi Lbs. Per Inches/Foot mm mm kpa N Coupling mm/m 1 1 2" 2" 2 1 2" 76.1mm 3" 4" 5" 165.1mm 6" 8" 10" 12" , ' ,447 6, , ' ,447 9, , ' ,447 14, , ' , , ' ,447 21, , ' ,447 35, , ' ,447 54, , ' , , ' ,447 76, , ' , , , ' , , , ' , , * Maximum available gap between pipe ends. Minimum gap = 0 Maximum pressure and end load are based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Protection for details. See Fire Protection Submittal Sheet for Listing and Approval pressure ratings. Installation Instructions Figure 575, 705 and 707 Couplings 29
30 Figure 707 (cont.) FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. Dimensions Bolt Bolt Net Pipe A B C Size** Torque Wt. Size Inches Inches Inches Dia x Lg. Lbs.-Ft. Lbs. mm mm mm Nm Kg " 2" 2 1 2" 76.1mm 3" 4" 5" 165.1mm 6" 8" 10" 12" /2" x 3" /2" x 3" /2" x 3" M12 x /2" x 3" /8" x /4" /4" x /4" M20 x /4" x /4" /8" x /2" " x /2" " x /2" **Metric Bolts used for 76.1mm and 165.1mm couplings. 30 Installation Instructions Figure 575, 705 and 707 Couplings
31 Figure 575, 705 & 707 Flexible Couplings Always read and understand the instructions. Never remove any piping component without verifying that the system is depressurized and drained. Rigid Couplings with Tri-Seal gaskets are preferred for dry pipe and freezer applications. Installation / Assembly Instructions The following instructions apply to Figures 575, 705 and 707 Flexible Couplings. The installation is based on pipe grooved in accordance with Standard Cut Groove or Roll Groove Specifications. Step 1. Inspect exterior groove and ends of the pipe to verify all loose debris, dirt, chips, paint and any other foreign material such as grease are removed. Pipe ends sealing surfaces must be free from projections, indentations, and/or other markings. Step 2. Verify that the coupling and gasket grade are correct for the application intended. Please refer to Gasket Grades and Gasket Recommendations literature for additional information. The edges and outer surfaces of the gasket should be covered with a fine layer of petroleum-free silicone lubricant or equivalent. Petroleum lubricant should not be used on Grade E EPDM or Grade A EPDMA gaskets to prevent deterioration of the gasket material. Rigid Couplings and Tri-seal gaskets are recommended for freezer applications. Prelubricated gaskets do not require added lubrication. Step 3. Install the gasket by placing the gasket over the pipe, which is to be fastened by the flexible coupling and ensure that the gasket lip does not extend beyond the end of the pipe. Installation Instructions Figure 575, 705 and 707 Couplings 31
32 Figure 575, 705 & 707 Flexible Couplings (cont.) Step 4. Bring both pipe ends together, ensure proper alignment and slide the gasket into position, properly centering it between the grooved portions of each pipe. Note: the gasket should not protrude into the grooves on either pipe segments or extend between the pipe ends. Step 5. With one nut and bolt removed, swing around as shown. Verify that the housings are over the gasket and that the housing keys are fully engaged into the grooves. Step 6. Insert the other bolt into the coupling and rotate the nuts until finger tight. Verify that the bolt heads are fully recessed in the housing. Step 7. Alternate between bolts when tightening nuts until properly torqued to bring housing in contact with the bolt pads. Note: uneven tightening can cause the gasket to pinch or bind. For proper bolt torques please refer to the table listed on the previous pages. Note: Figures 575, 705 and 707 Coupling Housing bolt pads must be in contact metal to metal. 32 Installation Instructions Figure 575, 705 and 707 Couplings
33 Figure 716 B C A Pipe Max. * Max. Max. Deflection Size O.D. End Gap Pressure End Load Inches Per Inches Inches psi Lbs. /Foot Coupling mm mm kpa N mm/m 2" x 1 1 2" 2 1 2" x 2" 3" x 2" 3" x 2 1 2" 4" x 2" 4" x 2 1 2" 4" x 3" 5" x 4" 6" x 4" 6" x 5" 8" x 6" x ' 60.3 x ,413 4, x , ' 73.0 x ,413 6, x , ' 88.9 x ,413 6, x , ' 88.9 x ,413 10, x , ' x ,413 6, x , ' x ,413 10, x , ' x ,413 14, x , ' x ,413 24, x , ' x , x , ' x , x , ' x , * Maximum available gap between pipe ends. Minimum gap =.06" with metal insert. Maximum pressure and end load are based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Protection for details. See Fire Protection Submittal Sheet for Listing and Approval pressure ratings. Installation Instructions Figure 716 Flexible Reducing Couplings 33
34 Figure 716 (cont.) FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. Dimensions Bolt Net Bolt Pipe A B C Torque Wt. Size Size Inches Inches Inches Lbs.-Ft. Lbs. Dia. x Lg. mm mm mm Nm Kg " x 1 1 2" 8" x 2 1 4" " x 2" 8" x 2 1 4" " x 2" 2" x 3" " x 2 1 2" 2" x 3" " x 2" 8" x 3 1 4" " x 2 1 2" 8" x 3 1 4" " x 3" 8" x 3 1 4" " x 4" 4" x 4 3 4" " x 4" 4" x 4 3 4" " x 5" 4" x 4 3 4" " x 6" 8" x 6 1 2" Installation Instructions Figure 716 Flexible Reducing Couplings
35 Figure 716 Flexible Reducing Couplings Always read and understand the instructions. Never remove any piping component without verifying that the system is depressurized and drained. Note: Reducing Couplings are not recommended for freezer applications. Installation / Assembly Instructions The following instructions apply to Figure 716 Flexible Reducing Couplings. The installation is based on pipe grooved in accordance with Standard Cut Groove or Roll Groove Specifications. Step 1. Inspect exterior groove and ends of the pipe to verify all loose debris, dirt, chips, paint and any other foreign material such as grease are removed. Pipe ends sealing surfaces must be free from projections, indentations, and/or other markings. Step 2. Verify that the coupling and gasket grade are correct for the application intended. Please refer to Gasket Grades and Gasket Recommendations literature for additional information. The edges and outer surfaces of the gasket should be covered with a fine layer of petroleumfree silicone lubricant or equivalent. Petroleum lubricant should not be used on Grade E EPDM or Grade A EPDMA gaskets to prevent deterioration of the gasket material. Prelubricated gaskets do not require added lubrication. Step 3. Install the gasket by placing the gasket over the pipe which has the larger diameter. Bring the smaller pipe end into alignment and slide the pipe into position, properly centering it between the grooved portions of each pipe. Note: the gasket should not protrude into the grooves on either pipe segment. Installation Instructions Figure 716 Flexible Reducing Couplings 35
36 Figure 716 Flexible Reducing Couplings (cont.) Step 4. With both bolts removed place the coupling housings over the gasket. Verify that the housings are over the gasket and that the housing keys are fully engaged into the grooves. Step 5. Insert the bolts into the coupling and rotate the nuts until finger tight. Verify that the bolt heads are fully recessed in the housing. Step 6. Alternate between bolts when tightening nuts until properly torqued to bring housing in contact with the bolt pads. Note: uneven tightening can cause the gasket to pinch or bind. For proper bolt torques please refer to the table listed on the previous pages. Note: Figure 716 Coupling Housings bolt pads must be in contact metal to metal. An optional Type 304 stainless steel metal insert is available. Pipe telescoping can be a concern when installed in the vertical position. If you are using a metal insert, place the insert inside the gasket, align the insert slots with the ribs on the gasket. 36 Installation Instructions Figure 716 Flexible Reducing Couplings
37 Figure 730 Grooved B C B C A A E A Figure 730 Mechanical Tee Grooved Outlet Figure 730 Mechanical Cross Grooved Outlet Nominal Max. Max. Dimensions Net Size Pressure End Load A B C E Wt. Run x psi (Branch) Inches Inches Inches Inches Lbs. Branch kpa Lbs. / N mm mm mm mm Kg. 2" x 1 1 /4" 2" x 1 1 /2" 2 1 /2" x 1 1 /4" 2 1 /2" x 1 1 /2" 3" x 1 1 /4" 3" x 1 1 /2" 3" x 2" 4" x 1 1 /4" 4" x 1 1 /2" 4" x 2" , , ,887 3,781 2,887 3,781 2,887 3,781 5,907 2,887 3,781 5, , " x 2 1 /2" 8, " x 76.1mm 4" x 3" 2,120 2, ,430 12, Maximum pressure and end load are based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Protection for details. See Fire Protection Submittal Sheet for Listing and Approval pressure ratings. Installation Instructions Figure 730 Mechanical Outlet 37
38 Figure 730 Grooved (cont.) FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. Nominal Max. Max. Dimensions Net Size Pressure End Load A B C E Wt. Run x psi (Branch) Inches Inches Inches Inches Lbs. Branch kpa Lbs. / N mm mm mm mm Kg. 5" x 1 1 /2" 5" x 2" 5" x 2 1 /2" 5" x 3" 6" x 1 1 /2" 6" x 2" 6" x 2 1 /2" 6" x 3" 6" x 4" 8" x 2 1 /2" 8" x 3" 8" x 4" 850 1,328 1,947 2, ,328 1,947 2,885 4,769 1,947 2,885 4, ,781 5,907 8,660 12,832 3,781 5,907 8,660 12,832 21,213 8,660 12,832 21, Maximum pressure and end load are based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Protection for details. See Fire Protection Submittal Sheet for Listing and Approval pressure ratings. 38 Installation Instructions Figure 730 Mechanical Outlet
39 Figure 730 Threaded B C B C D TAKEOUT A D TAKEOUT A E D TAKEOUT A Figure 730 Mechanical Tee Threaded Outlet Figure 730 Mechanical Cross Threaded Outlet Nominal Max. Max. Dimensions Net Size Pressure End Load A B C D E Wt. Run x psi (Branch) Inches Inches Inches Inches Inches Lbs. Branch kpa Lbs. / N mm mm mm mm mm Kg. 2" x 1 /2" 2" x 3 /4" 2" x 1" 2" x 1 1 /4" 2" x 1 1 /2" 2 1 /2" x 1 /2" ,156 1,810 2,887 3, /2" x 3 /4" 1, /2" x 1" 1, /2" x 1 1 /4" 2, /2" x 1 1 /2" 3, " x 1 /2" " x 3 /4" 1, " x 1" , " x 1 1 /4" 2, " x 1 1 /2" 3, , " x 2" 5, " x 1 /2" " x 3 /4" 1, " x 1" 1, Please see notes on previous page Installation Instructions Figure 730 Mechanical Outlet 39
40 Figure 730 Threaded (cont.) FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. Nominal Max. Max. Dimensions Net Size Pressure End Load A B C D E Wt. Run x psi (Branch) Inches Inches Inches Inches Inches Lbs. Branch kpa Lbs. / N mm mm mm mm mm Kg. 4" x 1 1 /4" 4" x 1 1 /2" 4" x 2" , ,887 3,781 5, , " x 2 1 /2" 8, " x 76.1mm 4" x 3" 2,120 2, ,430 12, " x 1 1 /2" 3, " x 2" 1, , , " x 2 1 /2" 8, , " x 76.1mm 9, , " x 3" 12, " x 1 1 /2" 3, , " x 2" 5, , " x 2 1 /2" 8, , " x 76.1mm 9, , " x 3" 12, , " x 4" 21, , " x 2 1 /2" 8, , " x 76.1mm 9, , " x 3" 12, , " x 4" 21, Please see notes on previous page 40 Installation Instructions Figure 730 Mechanical Outlet
41 Figure 730 Mechanical Outlet Always read and understand the instructions. Never remove any piping component without verifying that the system is depressurized and drained. Pipe Preparation Hole Dia. Nominal Size Hole Max. Run x Inches Inches Branch mm mm 2", 2 1 /2", 3", 4" x 1 1 /2 1 5 /8 1 /2", 3 /4", 1" " x 1 1 /4", 1 1 /2" /4 1 7 / /2" x 1 1 /4", 1 1 /2" / /4* 1 7 3", 4" x 1 1 /8 /4" ", 4", 5", 6" x 1 1 /2" / ", 4", 5", 6" x 2" 4", 5", 6", 8" x 2 3 /4 2 7 /8 2 1 /2", 76.1mm ", 5", 6", 8" x 3" /2 3 5 /8 2 1 /2 2 5 / ", 8" x 4" /2 4 5 / Step 1. The hole size should be verified in the table on the left. Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 5 /8 of the hole to be certain it is free from conditions which would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, which might affect assembly, proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendents, etc. may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. * Changed from 2" previously used on the Figure 720. Step 2. Hole must be drilled on the pipe centerline. For crosses, ensure double outlet holes are aligned. Step 3. Holes should be de-burred. The gasketseating surface on the pipe should be examined to verify all loose debris, dirt, chips, paint and any other foreign material such as grease are removed. Installation Instructions Figure 730 Mechanical Outlet 41
42 Installation / Assembly Instructions The following instructions apply to Figure 730 Mechanical Outlet Tee and Cross with threaded and grooved outlets. If a cross configuration is desired the lower housing is replaced with an upper outlet housing. Verify that the gasket grade is correct for the application intended. Please refer to Gasket Grades and Gasket Recommendations literature for additional information. Step 1. Check for proper gasket positioning in housing. The alignment tabs on the gasket should fit into the recesses of the housing. Gasket lubrication is not required on this product. Step 2. With one nut and bolt removed, swing around as shown. Step 3. Verify that the housing outlet spike is positioned in the hole. Insert the other bolt into the housing and rotate the nuts clockwise until finger tight. Verify that the bolt heads are fully recessed in the housing. Step 4. Alternate between bolts when tightening nuts until properly torqued with even gaps between the bolt pads. Note: uneven tightening can cause the gasket to pinch or bind. For proper bolt torques please refer to the table listed below. Pipe Size (Run) Bolt Bolt Torque Inches Size Lbs. - Ft. 2" " 3 8" 30 3" - 4" 1 2" 50 5" 5 8" 50 6" 5 8" 70 8" 3 4" Installation Instructions Figure 730 Mechanical Outlet
43 Figure 40-5 Strap 3 2 C 1 FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. 4 B A D Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Nominal Size Dimensions Net A B C D Wt. Run x Branch Inches Inches Inches Inches Lbs. mm mm mm mm Kg. 1 1 /4" x 1 /2" 1 1 /4" x 3 /4" 1 1 /4" x 1" 1 1 /2" x 1 /2" 1 1 /2" x 3 /4" 1 1 /2" x 1" " x 1 /2" " x 3 /4" " x 1" /2" x 1 /2" /2" x 3 /4" /2" x 1" Pressure Rating = 175 psi (1207 kpa) Installation Instructions Figure 40-5 Strap 43
44 Figure 40-5 Strap Always read and understand the instructions. Never remove any piping component without verifying that the system is depressurized and drained. Pipe Preparation The Pipe should be examined for the following: Nominal Size Hole Size Inches mm Step 1. The hole size should be verified in the table on the left. 1 1 /4" x 1 /2" 1 1 /4" x 3 /4" 1 1 /4" x 1" 1 1 /2" x 1 /2" 1 1 /2" x 3 /4" 1 1 /2" x 1" 2" x 1 /2" 2" x 3 /4" 2" x 1" 2 1 /2" x 1 /2" 2 1 /2" x 3 /4" 2 1 /2" x 1" 1 3 / / / / / / / / / / / / Step 2. Hole must be drilled on the pipe centerline. Step 3. Holes should be de-burred. The gasketseating surface on the pipe should be examined to verify all loose debris, dirt, chips, paint and any other foreign material such as grease are removed. 44 Installation Instructions Figure 40-5 Strap
45 Installation / Assembly Instructions The following instructions apply to Figure 40-5 Strap. Verify that the gasket grade is correct for the application intended. Please refer to Gasket Grades and Gasket Recommendations literature for additional information. Step 1. Check for proper gasket positioning in housing. Gasket lubrication is not required on this product. Step 2. To assemble the strap on the pipe, remove the U bolt. Place the outlet housing over the hole in the pipe. Verify that the housing spike is positioned in the hole. Step 3. Insert the U bolt into the housing and rotate the nuts clockwise until finger tight. Step 4. Alternate between tightening nuts until properly torqued. The torque should not exceed 15 lbs.-ft. (20 Nm) on pipe with a wall thickness less than Schedule 10, or 25 lbs.-ft. (34 Nm) for Schedule 10 and above. Overtorqueing can damage thin wall pipe and will not increase sealing efficiency. Installation Instructions Figure 40-5 Strap 45
46 Figure 71 A C FM F B E D See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. Dimensions Pipe A B C D* E* F Size Inches Inches Inches Inches Inches Inches mm mm mm mm mm mm 2" 2 1 2" 3" 4" 5" 6" 8" 10" 12" * Dimensions D and E represent minimum and maximum sealing surfaces. 46 Installation Instructions Figure 71 Flange Adapter
47 Figure 71 (cont.) Pipe Max. Max. Bolt Net Size O.D. Pressure End Load Torque Wt. Size Inches psi Lbs. Qty. Lbs.-Ft. Lbs. Dia. x Lg. mm kpa N Nm Kg. 2" 2 1 2" 3" 4" 5" 6" 8" 10" 12" , " x 3" ,724 4, , " x 3" ,724 7, , " x 3" ,724 10, , " x 3" ,724 17, , " x 3 1 2" ,724 27, , " x 3 1 2" ,724 38, , " x 3 1 2" ,724 64, , " x 4" , , , " x 4" , , Maximum pressure and end load are based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Protection for details. See Fire Protection Submittal Sheet for Listing and Approval pressure ratings. * Note: Bolts and nuts are not supplied. Bolt lengths shown are standard; it is the responsibility of the purchaser to verify correct length for the intended application. Figure 71 Flange Adapter Always read and understand the instructions. Never remove any piping component without verifying that the system is depressurized and drained.- Installation / Assembly Instructions The following instructions apply to Figure 71 Flange Adapter. The installation is based on pipe grooved in accordance with Standard Cut Groove or Roll Groove Specifications. Step 1. Inspect exterior groove and ends of the pipe to verify all loose debris, dirt, chips, paint and any other foreign material such as grease are removed. Pipe ends sealing surfaces must be free from projections, indentations, and/or other markings. Installation Instructions Figure 71 Flange Adapter 47
48 Figure 71 Installation / Assembly Instructions (cont.) Step 2. Verify that the gasket selection is correct for the application intended. Please refer to Gasket Grades and Gasket Recommendations literature for additional information. Insert one flange bolt (not supplied) in hinge section of Figure 71 Flange Adapter. Place the hinged assembly into the groove on the pipe. Step 3. Close the flange with another bolt. To ease in the closure of the flange, two tabs are provided. Take an adjustable wrench and place it over the two tabs as shown. Move the wrench parallel to the pipe until the holes align. Once the holes align insert a bolt. Verify that the housing keys are fully engaged into the groove. Step 5. The edges and outer surface of the gasket should be covered with a fine layer of petroleum-free silicone lubricant or equivalent. Petroleum lubricant should not be used on Grade E EPDM or Grade A EPDMA gaskets to prevent deterioration of the gasket material. Step 6. Place the gasket into the gasket pocket with the gasket marking side in first. Step 7. Bring both the Figure 71 Flange and the opposite Flange together. Ensure proper alignment and slide each of the remaining flange bolts (not supplied) in each of the remaining bolt holes. Tighten all nuts uniformly to bring the flange faces firmly together and ensure that the nuts are sufficiently torqued. (see torque values on previous page) Note: Metal flange washer adapters are required when the Figure 71 Flange Adapter is used against surfaces such as: 1. Rubber surfaces 2. Adapting to AWWA cast flanges 3. Rubber faced wafer valves 4. Serrated flange surfaces Figure 71 Flange Adapters are not recommended for applications which incorporate tie rods for anchoring or on a standard fitting within 90 of each other. Contact Tyco Fire Products for recommendations prior to using with plastic pipe. 48 Installation Instructions Figure 71 Flange Adapter
49 Figure 570 and 580 F POSITION INDICATOR A B C FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. D Front view with valve open G E Side view with valve open G A B C D E F G Net Wt. Size Inches Inches Inches Inches Inches Inches Inches lbs. mm mm mm mm mm mm mm Kg " 3" 4" 5" 6" 8" 10"** 12"** N/A* N/A* N/A* N/A* N/A* * - end of disc does not extend beyond valve body ** - Contact Tyco Fire Products for availability Supervisory Tamper Switch Circuits (Valve Fully Open) S1 S2 CHASSIS NC NO COM COM NC NO WHT/ORN Fire Alarm Control Panel Supervisory Circuit BLK RED WHT BLK/ORN RED/ORN Auxiliary Signal Device End of Line Resistance Or, Next Device Voltage Source Utilization and Connection of Auxiliary Switch to be Reviewed and Approved by the Local Authority Having Jurisdiction Pressure Ratings: Figure 570 = 175 psi (1207 kpa) Figure 580 = psi (2068 kpa) Switch Rating: 10A 125,250 VAC 0.25A 250 VDC 0.50A 125 VDC Installation Instructions Control Valves 49
50 Butterfly Valves Always read and understand the instructions. Never remove any piping component without verifying that the system is depressurized and drained. These valves are furnished with grooved ends and can be installed using Grooved Flexible or Rigid Couplings. To prevent rotation of the valves it is recommended that the Butterfly Valve be installed with rigid type couplings, such as the Figure 572 or 772. If flexible couplings are used, additional support may be needed to prevent rotation. Butterfly Valves should be located where they will by readily accessible for operation inspection and maintenance. All replacement parts must be obtained from Tyco Fire Products to assure proper operation of the valve. When ordering parts please specify model number and size. Butterfly Valves in sizes 8, 10, and 12 inches must be closed prior to installation as the disc extends beyond the valve body. If the valve is installed with the disc extended mechanical damage to the disc can occur. Supervisory Switch Replacement For ease of replacement, the kit consists of a new gear operator with internal switches. Note: Before replacing the gear operator with switches, verify that the wiring is per the wiring diagram found in step 7. IMPORTANT: All replacement parts must be obtained from the manufacturer to assure proper operation of the valve. Warning: Any system maintenance or inspection that involves placing a valve "out-of-service" will eliminate the fire protection normally provided by the fire protection system. Prior to proceeding, be certain to secure permission from all Authorities Having Jurisdiction and notify all personnel who may be affected during system shutdown. A fire watch during maintenance periods is a recommended precaution. 50 Installation Instructions Control Valves
51 Butterfly Valves Warning (cont.): The owner is responsible for the proper operating condition of all fire protection devices and accessories. The NFPA Standard 25 entitled, "Care and Maintenance of Sprinkler Systems" contains guidelines and minimum maintenance requirements. Futhermore, the Authority Having Jurisdiction may have additional regulations and requirements for maintenance, testing and inspection that must be obeyed. E A B D C DANGER: To reduce the risk of electric shock disconnect the electrical power to the switches. Important: Marking the lead wires will aid in reconnecting the replacement wiring in Step 7. Step 1. Disconnect electrical power and all lead wires to the switch circuit. Step 2. Remove the indicator (A) by using a pin punch and a hammer to drive out the roll pin (B) (Save these parts). Step 3. Remove the hand wheel (C) by using a pin punch and a hammer to drive out the pin (D) (Save these parts). Important: pin (D) is a special UL Section of Weakness pin. Use only this part. If it is damaged, order a replacement part from Tyco Fire Products. Installation Instructions Control Valves 51
52 Butterfly Valves Step 4. Remove the mounting bolts (E) (Save these parts) and carefully remove the gear operator off the upper stem ensuring that the key is not lost (see photo). Inspect the key and if it appears to be damaged, order a replacement part from Tyco Fire Products. Important: this key is a special FM requirement; do not substitute another component. Should the key fall out, apply a little grease to the key to help it stick in place. Step 5 Install the new gear operator with bolts (E) from step 4. Step 6 Replace the handwheel (C) with pin (D) and replace the indicator (A) with pin (B). Step 7 Connect all of the lead wires to the switch circuit (see wiring diagram below). Supervisory Tamper Switch Circuits (Valve Fully Open) Fire Alarm Control Panel Supervisory Circuit S1 S2 CHASSIS NC NO COM COM NC NO WHT/ORN BLK RED WHT BLK/ORN RED/ORN Auxiliary Signal Device End of Line Resistance Or, Next Device Voltage Source Utilization and Connection of Auxiliary Switch to be Reviewed and Approved by the Local Authority Having Jurisdiction Step 8 Conduct testing to verify operation. 52 Installation Instructions Control Valves
53 Figure 590F B A C CHECK VALVE D 1/2" NPT F E J 1/2" NPT A B C D E F G Net Wt. Size Inches Inches Inches Inches Inches Inches Inches lbs. mm mm mm mm mm mm mm Kg " 3" 4" 5" 6" 8" Pressure Rating for Figures 590F and 590FR = psi (2068 kpa) FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. Installation Instructions Figure 590 Check Valve 53
54 Figure 590FR K Central System Side Gauge USA CHECK VALVE FIG. 590 SIZE PSI YR OF MFG CENTRAL J H A Supply Side Gauge Central C Main Drain Main Drain F G B D A B C D E F G H J K Net Wt. Size Inches Inches Inches Inches Inches Inches Inches Inches Inches Inches Lbs. mm mm mm mm mm mm mm mm mm mm Kg " 3" 4" 5" 6" 8" Trim Kit 2 1 /2" & 3" Trim Kit 4", 5", 6" & 8" Riser Check Valve Riser Check Valve Main Drain Main Drain 1 1 /4" X 2 1 /2" Nipple 2" X 2 1 /2" Nipple 1 1 /4" M X F Ball Valve 2" M X F Ball Valve 1 1 /4" 90 Elbow 2" 90 Elbow Gauge (system side) Gauge (system side) 0- psi Gauge 0- psi Gauge 1 /4" X 2" Nipple 1 /4" X 2" Nipple 1 /4" Three-Way Globe Valve 1 /4" Three-Way Globe Valve 1 /4" Plug 1 /4" Plug Gauge (supply side) Gauge (supply side) 0- psi Gauge 0- psi Gauge 1 /4" X 5" Nipple 1 /4" X 5" Nipple 1 /4" Three-Way Globe Valve 1 /4" Three-Way Globe Valve 1 /4" Plug 1 /4" Plug FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information. 54 Installation Instructions Figure 590 Check Valve
55 Figure 590 Check Valve Always read and understand the instructions. Never remove any piping component without verifying that the system is depressurized and drained. These valves are furnished with grooved ends and can be in installed using Grooved flexible or rigid couplings. Please refer to the installation instruction for the particular coupling. These valves may be installed in either horizontal or vertical piping systems. The arrow cast into the valve body must point in the direction of the flow. Repair Instruction (Figure 590F and 590FR) All replacement parts must be obtained from Tyco Fire Products to assure proper operation of the valve. When ordering parts please specify model number and size. Step 1. Remove the bolts from the cap. Step 2. Inspect the nickel seating surface to verify the there is no evidence of mechanical damage. The seat also needs to be free of all loose debris. If the seat is damaged the entire valve will need to be replaced. Step 3. Inspect the elastomer seal facing the spring loaded clapper to verify that there is no evidence of mechanical damage. If there is damage to the elastomer seal and you have a clapper repair kit then proceed to Step 4. Step 4. Inspect new replacement clapper subassembly. Step 5. Remove the old bonnet gasket material and clean. Place a new gasket on the cleaned surface. Installation Instructions Figure 590 Check Valve 55
56 Figure 590 Check Valve Step 6. Insert replacement clapper sub assembly into check valve body. Step 7. Apply Loctite #242 to bolts. Tighten all nuts uniformly bring the cap and gasket faces firmly together and ensure that the nuts are torqued properly as listed in the table below. Check Valve Bolt Torque Size Lbs. - Ft ", 3" 30 4", 5" 32 6" 54 8" 58 Maintenance Kit for Figure 590F Check Valve The Maintenance Check Valve Kit is specially designed to allow the maintenance procedure of backflushing through the fire department connection. The maintenance kit is intended to ease the task of backflushing without removing the Figure 590F Check Valve from the pipe line. This is accomplished by replacing the cap / clapper assembly with the maintenance kit (see Installation section for full procedure). IMPORTANT: All replacement parts must be obtained from the manufacturer to assure proper operation of the valve. Never remove any piping component without verifying that the system is depressurized and drained. The owner is responsible for the proper operating condition of all fire protection devices and accessories. The NFPA Standard 25 entitled, "Care and Maintenance of Sprinkler Systems" contains guidelines and minimum maintenance requirements. Futhermore, the Authority Having Jurisdiction may have additional regulations and requirements for maintenance, testing and inspection that must be obeyed. 56 Installation Instructions Figure 590 Check Valve
Grooved Fire Protection. Installation Handbook
Grooved Fire Protection Installation Handbook October 2016 Grooved Fire Protection Installation Handbook OCTOBER 2016 IH-1000FP Worldwide Contacts www.tyco-fire.com GLOBAL HEADQUARTERS 1400 Pennbrook
More informationProduct Submittals for Project
Product Submittals for Project May 011-1 Couplings Figure 577 Light Weight Rigid Coupling For Fire Protection Pressure Rating and Listing / Approval information contact Tyco Fire Suppression & Building
More informationCouplings. Ductile Iron Housing Specifications. Coatings. Gasket Specifications. Bolt/Nut Specifications
Figure 71 Flange Adapters (ANSI Class 5/150) The Figure 71 Flange Adapter is capable of pressures up to 300 psi (20,7 bar) depending on pipe size and wall thickness. It provides a direct transition from
More informationB U I L D I N G C O N N E C T I O N S T H AT L A S T
B U I L D I N G C O N N E C T I O N S T H AT L A S T pipe to pipe and people to people. We pride ourselves in providing the finest-quality pipe products and services with integrity and dedication to superior
More informationGROOVED COUPLINGS - STANDARD FLEXIBLE Model 101
GROOVED COUPLINGS - STANDARD FLEXIBLE Model 101 Available Sizes 1" through 12" (25 through ) Pipe Material Carbon steel, Schedule 10, Schedule 40. For use with alternative materials and wall thicknesses
More informationMechanical MATERIAL SPECIFICATIONS. Stainless Steel Housing Specifications. Gasket Specifications. Bolt / Nut Specifications
82 COUPLINGS SYSTEM The Grinnell Stainless Steel System is designed for joining 2" to 12" (54,0mm to 206,4mm) stainless steel piping, schedules 5, 10, and 40. The Figure 472 coupling patented Universal
More informationFIG Gruvlok Flanges
Gruvlok Flanges The Gruvlok Fig. 7012 Flange allows direct connection of Class 125 or Class 150 flanged components to a grooved piping system. The two interlocking halves of the 2" thru 12" sizes of the
More informationAdvantages of Grooved Fittings
Grooved Fittings Advantages of Grooved Fittings Comparative Advantages Allows angular deflection-misalignment Expansion, contraction or, no need for expansion joint Reclaimable, no need for union Allows
More informationGrinnell Grooved Fire Protection Products Grooved Fittings
Technical Services: Tel: (800) 38-932 / Fax: (800) 79-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittings General Description LPCB Vd S The grooved fittings provide an economical
More informationGRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description
Worldwide Contacts www.grinnell.com GRINNELL Model B0 and Model BN0 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description The GRINNELL Model B0 and Model BN0 Butterfly
More informationSTAINLESS STEEL SYSTEMS
STAINLESS STEEL SYSTEMS 139 Systems Table of Contents Figure 472 Rigid Couplings Page 142 Figure 401 45 Elbows Page 149 Figure SS-7X Rigid Couplings (Large Diameter) Page 143 Figure 405 Flexible Couplings
More informationStyle 234 Restrained Flexible Single-Gasket Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date
Victaulic Bolted Split-Sleeve Products (VBSP) Style 234 carbon steel couplings (formerly Depend-O-Lok Air/FluidMaster) are single-arch couplings that are commonly used in buried or exposed steel pipe applications
More informationModel 7706 Reducing Coupling. Deg. Axial Displacement
MODEL 7706 REDUCING COUPLING The Model 7706 Reducing allows direct reduction on a piping run and eliminates the need for a concentric reducer and couplings. The specially designed rubber gasket prevents
More informationINTRODUCTION. General Notes
INTRODUCTION Thank you for selecting a Shurjoint product. This manual covers the proper installation and assembly procedures for your product. To ensure the proper installation, assembly and performance
More informationGRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description
Worldwide Contacts www.grinnell.com GRINNELL Model B Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description The GRINNELL Model B Butterfly Valves provide for efficient
More informationFIG Gruvlok Flange Adapter
FIG. 88 Gruvlok Adapter The Gruvlok Fig. 88 Adapter allows for direct connection of Class 125 or Class 150 flanged components to a grooved piping system. The Gruvlok Adapter provides an alternative method
More informationFIRE SPRINKLER EQUIPMENT SUBMITTAL
Fire Systems West, Inc. 206 FRONTAGE ROAD NORTH, SUITE C PACIFIC, WA 98047 (253) 833-1248 FIRE SPRINKLER EQUIPMENT SUBMITTAL FOR Being 4-20-21 VPAL MAINTENANCE SHED AND SUBSTATION FSW JOB NO. 02-11-11013
More informationThe applicable material specifications for ductile iron and rubber gaskets apply:
72 COUPLINGS - Grinnell Copper Grooved System is designed for joining copper tube size components 2" to 8" (54,0mm to 206,4mm) type K, L, M and DWV. All couplings and fittings are rated for working pressures
More informationHousing Coating: Orange enamel. Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The patented Style 107H rigid coupling joins 8"/50 200 standard roll grooved and cut grooved steel pipe.* The joint is assembled without disassembling the bolts,
More informationTechnical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved
Worldwide Contacts www.tyco-fire.com Model TJP Resilient-Seated Gate Valves with Vertical or Cross Wall Post Indicator General Description TYCO Model TJP Resilient-Seated Gate Valves with Vertical and
More informationMechanical Piping Products
October 202 For the most current product/pricing information on Anvil products, please visit our website at www.anvilintl.com. Mechanical Piping Products b u i l d i n g c o n n e c t i o n s t h a t l
More informationHole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole
Mechanical Tees Hole-cutting Shurjoint mechanical tees provide a fast and easy mid-point branch outlet, eliminating the need for welding or the use of multiple fittings. The Model M21 features a female
More informationQuickVic Rigid Coupling for Steel. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE GROOVED COUPLINGS
H ONL. SEE PAGE 4 FOR DETAILS. The patented Style 107 rigid coupling joins 12"/50 300 standard roll grooved and cut grooved steel pipe. The joint is assembled without disassembling the bolts, nuts, gasket
More information030/TL 03/01 50M, Copyright 2001, Anvil International $3. 50
030/TL 03/01 50M, Copyright 2001, Anvil International $3. 50 Pipe Fitter Handbook Another Anvil Advantage Mini-catalog Installation Procedures Technical Data Copyright 2001 by Anvil International, Inc.
More informationFord Fabricated Steel Products
Ford Fabricated Steel Products Section N2 12/2000 The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487 Overseas
More informationINTEGRATED PIPING SYSTEMS. Technical manual. Fire Protection
INTEGRATED PIPING SYSTEMS Technical manual Fire Protection Disclaimer: This technical data is non-binding and may not reflect the guaranteed characteristics of the products, which are subject to change.
More informationREQUEST PUBLICATION 18.11
* SEE VICTALIC PBLICATION 10.01 FOR DETAILS The Victaulic Pressfit 316 System for joining approved Type 316/316L stainless steel pipe provides a fast, easy, clean, reliable means for joining ½"/15, ¾"/
More informationTECHNICAL DATA OBSOLETE
August 31, 2006 Check Valve 815a 1. PRODUCT NAME Viking Easy Riser Swing Check Valve Model E-1: Available since 1992 Model F-1: Available since 1994 2. MANUFACTURER The Viking Corporation 210 N. Industrial
More informationTRUSTED FOR 150 YEARS
G-2005 Today Anvil International is the largest and most complete fitting and hanger manufacturer in the world. 2004 Anvil International acquires Star Pipe Products, Building and Construction Divisions
More informationSECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.
SECTION 210500 - COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, valves, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS A. Section 099000
More informationStyle 99 Roust-A-Bout Couplings
R IPS CARBON STEEL PIPE PLAIN END SYSTEM Style 99 Roust-A-Bout Couplings 14.02 VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY PRODUCT DESCRIPTION 1 1 / 2-12" Sizes 14-18" Sizes Style 99 Roust-A-Bout couplings
More informationEasy Riser swing check valve Models E-1 & F-1
Page 1 of 7 1. DESCRIPTION The Viking Easy Riser Swing Check Valve is a general purpose rubber-faced approved for use in fire service systems. The valve is for use in wet system risers, preaction system
More informationStainless Steel Pipe System. System No. Submitted By Spec Sect Para Location Date Approved Date TEMPERATURE ( F/ C)
The Victaulic Vic-Press 304 System for joining approved Type 304/304L stainless steel pipe provides a fast, easy, clean, reliable means for joining 1/2"/15, 3/4"/20, 1"/25, 1 1/2"/40, and 2"/50 stainless
More informationModel CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data
Worldwide Contacts www.tyco-fire.com Model CV-FR Grooved-End Riser Check Valves Inch to Inch (DN0 to DN00) General Description The TYCO Model CV-FR Grooved- End Riser Check Valve is a compact and rugged
More informationwith the specific application. Always read and understand the installation
Worldwide Contacts www.tyco-fire.com Resilient-Seated Gate Valves Outside Screw and Yoke General Description TYCO Resilient-Seated Gate Valves are used in Fire Protection Systems for on/off operation.
More informationGRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description
Technical Services -00- +-0--0 www.grinnell.com GRINNELL Model B0 and Model BN0 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description The GRINNELL Models B0 and BN0
More informationSEE VICTAULIC PUBLICATION FOR DETAILS
dapters SEE VICTULIC PULICTION 10.01 FOR DETILS Style 741 Style 741 adapter is designed for directly incorporating flanged components with NSI CL. 125 or CL. 150/PN10 and PN16 or ustralian Standard Table
More informationCOOPLOK Grooved Submittal. Material Specifications
SmithCooper International (SCI) COOPLOK Submittal Directions: Enter in the project information below; then print. Project /Job: Date: Engineer/rchitect: Contractor: ddress: Notes: Project Information System:
More informationSize Inches UL ULC FM. Pipe Sch.
IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS FireLock Rigid Coupling STYLE 005 WITH VIC-PLUS GASKET SYSTEM (NORTH AMERICA ONLY) FireLock Style 005 rigid coupling has a unique, patented angle-pad design
More informationPipe hanger solutions
Product catalog Middle East offering Pipe hanger solutions for commercial and industrial applications B00 series B00 - Standard clevis hanger Pipe will not pinch when installing. 5 swing in either direction
More informationHot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Style 177 QuickVic flexible coupling is installation-ready, and joins 2-8"/50-200 standard roll grooved and cut grooved steel pipe. The coupling's unique
More informationSection 3. Stainless Steel Series. Shurjoint Stainless Steel Piping Series Grooved Mechanical Couplings. Cast Grooved Fittings.
Section 3 Stainless Steel Series Shurjoint Stainless Steel Piping Series... 84 Grooved Mechanical ouplings SS-5 Rigid oupling... 85 SS-7 Rigid oupling... 86 SS-7X Rigid oupling... 87 SS-8 Flexible oupling...
More informationVictaulic Standard Grooved and Advanced Grooved (AGS) Piping System for IPS Steel 2 (DN 50) through 60 (DN1500)
Victaulic Standard Grooved and Advanced Grooved (AGS) Piping System for IPS Steel 2 (DN 50) through 60 (DN1500) 1.01 General: A. Section Includes: 1. General 2. Materials: a. Pipe b. Victaulic Couplings
More informationROMAC INDUSTRIES, INC. WIDE RANGE RESTRAINT. RESTRAINED END CAP page 6-7 NOW AVAILABLE FOR HDPE PIPE NO STIFFENER REQUIRED
ROMAC INDUSTRIES, INC. WIDE RANGE RESTRAINT RESTRAINED COUPLING page 4-5 RESTRAINED END CAP page 6-7 RESTRAINED FLANGED COUPLING coming soon JUNE 2014 UPDATE NOW AVAILABLE FOR HDPE PIPE NO STIFFENER REQUIRED
More informationSmith-Blair OMNI Coupling System Advantages:
OMNI Coupling System SmithBlair s OMNI Coupling System utilizes the tremendous tensile strength of ductile iron to your best advantage. Applying the principles of space age technology to engineer the OMNI
More informationA. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.
SECTION 220523 - PLUMBING VALVES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Ball valves. 2. Butterfly valves. 3. Swing check valves. 4. Spring loaded check valves. 5. Water pressure reducing
More informationStyle Flange Adapter
Style 007 -- Flange Adapter Style 007 -- Flange Adapter is used for connect switches where valves, equipments or pipes have a flange interface. It realizes the change between flange connection and grooved
More informationGrooved Piping System for Fire Protection Services
Grooved Piping System for Fire Protection Services 1.01 General: A. Section Includes: 1. General 2. Materials: a. Pipe b. Victaulic Couplings c. Victaulic Fittings d. Hole and Branch Outlets e. Victaulic
More informationI-795/906. Series 795 and 906 Installation-Ready Knife Gate Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS
INSTALLATION AND MAINTENANCE INSTRUCTIONS I-795/906 Series 795 and 906 Installation-Ready Knife Gate Valves HANDWHEEL OPERATOR PNEUMATIC OPERATOR HYDRAULIC OPERATOR WARNING Read and understand all instructions
More informationUtilities Catalog. PC-U2008, February, 2008
Utilities Catalog PC-U2008, February, 2008 Tyler Utilities 11910 CR. 492 Tyler, Texas 75706 (800) 527-8478 Union Foundry Company Box 309 Anniston, Alabama 3602 (800) 226-7601 TABLE OF CONTENTS Item Page
More informationSteel Fabricated Coupling
Steel Fabricated Coupling Straight Connection IMPORTANT LINKS Click appropriate words to go to: Standard Limited Warranty Sales Terms & Conditions Freight Policy Returns Policy Corrosion & Product Selection
More informationVic-Strainer WARNING. System No. Submitted By Spec Sect Para Location Date Approved Date IPS CARBON STEEL PIPE - GROOVED ACCESSORIES SERIES 730
Series 730 Vic-Strainer is lighter than flanged Y type strainers and provides straightthrough flow for lower pressure drop. It installs with two Victaulic couplings, and is rated up to 750 psi/5175 kpa
More informationFord Service Saddles and Tapping Sleeves
DQS Inc. Section AA 09/2017 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Ford Service Saddles and Tapping Sleeves Contents Recommended Product Application *Steel *C900/909*** Cast
More informationSection N. 09/2017 Web Revision 10/23/2017 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001: Ford Fabricated Steel Products
DQS Inc. THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Section N 09/2017 Web Revision 10/23/2017 Ford Fabricated Steel Products Contents Page Product Numbering System... 3 Information...............................................................
More informationTHOMAS. Unifit Premier Series. Couplings & Flange Adaptors Non Restrained Products PIPE PRODUCTS
THOMAS Couplings & Flange Adaptors Non Restrained Products PIPE PRODUCTS Unifit Premier Series Universal Pipe Couplings and Flange Adaptors for all Rigid Pipe J1 Unifit Premier Series Application Locally
More informationIntroduction. We stay ahead of today s evolving market requirements by committing to a program of continued research and development.
Pipes & Fittings SHIELD Introduction SHIELD is a company created to cater to the infrastructure, fire protection and building services industries with a comprehensive range of products designed to be competitive
More informationTABLE OF CONTENTS. Pipe Diameter Chart (Reference Only)..50 Extensions 38,40,42,44
TABLE OF CONTENTS Item Page Item Page ANSI/AWWA Compact & Full Body Pipe Fittings: Product Submittals and Installation: Mechanical & Flange Joint C153. 3-9 20U Protective Fusion Bonded Epoxy....5,5 Mechanical
More informationSection 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings
Section 2 Cast & Wrought Grooved Fittings Shurjoint Grooved Fittings... 56 Flow Data / Friction Resistance... 56 Ductile Iron Grooved Fittings 7110 / 7111 / 7112 / 7113 Elbows... 57 7120 / 7135 / 7130
More informationInstructions for Installation, Operation, Care and Maintenance
Bulletin 407 Rev. T Model E Alarm Check Valve Bulletin 407 Rev. T Instructions for Installation, Operation, Care and Maintenance 4 (100 mm), 6 (150 mm), 8 (200 mm) Sizes With Model E3 Trim Listed by Underwriters
More informationVictaulic Suction Vibration Isolation Pump Drop Series 337 Korea Only
Victaulic Suction Vibration Isolation Pump Drop Series 337 Korea Only 2.37 1.0 PRODUCT DESCRIPTION Available Sizes 3 12"/DN80 DN300 Maimum Working Pressure Rated to the working pressure of the PN/PN16
More informationHANGERS, STRUT, AND FITTINGS SUBMITTAL
HANGERS, STRUT, AND FITTINGS SUBMITTAL Prepared By: Submitted by: Enter Company Name INTERNATIONAL SEISMIC APPLICATION TECHNOLOGY A Division of Tomarco Contractor Specialties Enter Project Name 4848 Northam
More informationEngineering Data. Assembly Length. How to Determine Correct Assembly Length
Assembly Length How to Determine Correct Assembly Length For most assemblies, the correct assembly length may be determined by direct measurement of the equipment or a drawing. Minimum bend radii as shown
More informationPBV s Engineering Excellence At Work
PBV s Engineering Excellence At Work The PBV Series 5700/6700 Three-Piece, Side-Entry, Trunnion Ball Valve 2"- 56" ANSI Class 150/300,600,900,1500 & 2500 In Full And Standard Port PBV trunnion ball valves
More informationInstructions for Installation, Operation, Care and Maintenance
Model D Dry Pipe Valve Bulletin 350 Rev. S Bulletin 350 Rev. S Instructions for Installation, Operation, Care and Maintenance 4 (100mm) 6 (150mm) Valve With Model D Trimmings Listed by Underwriters Laboratories,
More informationINSTALLATION, OPERATION, and MAINTENANCE GUIDE NIBCO Wall Mount Indicator Posts Series NIP-2AW
INSTALLATION, OPERATION, and MAINTENANCE GUIDE NIBCO Wall Mount Indicator Posts Series NIP-2AW PATENT #US 9,541,218 NIBCO Series NIP-2AW Wall Mount Indicator Posts are designed and manufactured to: Operate
More informationGrooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 60"/1500 in a variety of straight and reducing styles. Most standard fittings are cast of durable
More informationcontents MALLEABLE PIPE FITTINGS BUsHEs NiPPlEs PlUgs caps BENds BackNUTs UNioNs TEEs 171 cross PN25 p socket PN25 p socket PN25 p.
contents BUsHEs 140 Hexagon Bush p.5 NiPPlEs 144 octagon Nipple p.6 145 Hexagon Nipple p.6 PlUgs 146 Beaded Plug - solid p.7 147 Plain Plug - Hollow p.7 148 Plain Plug - solid p.7 149 countersunk Plug
More informationSECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.
SECTION 23 05 23 GENERAL-DUTY VALVES FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section includes valves for building services piping. 1.2 REFERENCES A. AGA Z21.22 (American Gas Association) - Relief Valves
More informationintroduction FE Series Butterfly Valves Product Data Sheet
Product Data Sheet introduction < STANDARDS > ASTM D1784 IPEX FE Series Butterfly Valves incorporate many features of our industrial FK valve, yet the all PVC construction and EPDM liner make this valve
More informationSeries 756 FireLock Dry System Check Valve
R IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS Series FireLock Dry System Check Valve Grooved X Grooved and Flanged X Grooved 0.0 VICTAULIC IS AN ISO 900 CERTIFIED COMPANY PRODUCT DESCRIPTION The Victaulic
More informationHerpteraium SECTION VALVES GENERAL
SECTION 22 05 23 VALVES GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationJCM 101 Universal Clamp Couplings
JCM 1 Universal Clamp Couplings JCM 1 Universal Clamp Coupling - Single Band JCM Universal Clamp Couplings provide a full circumferential seal and wide range for the permanent repair or reconnection of
More information2-20 (50mm-500mm) SERIES 30/31 Wafer/Lug RESILIENT SEATED BUTTERFLY VALVES. The High Performance Company
BUTTERFLY VALVES RESILIENT SEATED SERIES 30/31 Wafer/Lug 2-20 (50mm-500mm) The High Performance Company SERIES 30/31 2-20 (50mm-500mm) Bray Controls is proud to offer a high quality line of butterfly valves
More informationGrooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 48 /1200 in a variety of straight and reducing styles. Most standard fittings are cast of durable
More informationGrooved Piping System for Fire Protection Services
Grooved Piping System for Fire Protection Services 1.01 General: A. Section Includes: 1. General 2. Materials: a. Pipe b. Victaulic Couplings c. Victaulic Fittings d. Hole and Branch Outlets e. Victaulic
More informationFord Brass Saddles Style 101B and 202B
101B Ford Brass Saddles 101B and 202B 101B, 3/4" and 1" Taps 202B, 3/4" through 2" Taps Specifications Body - 85-5-5-5 brass alloy as per ASTM B62, ASTM B584 and AW WA C800. Threads may be FIP, AW WA,
More informationI-731-D/W731-D. Suction Diffuser. Important Installation Information. series 731-D and W731-D
Important Installation Information WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping
More informationI-232.T3S2 Victaulic Style 232 Restrained, Flexible High-Pressure Coupling
WARNING Read and understand all instructions before attempting to install any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic
More informationGrooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 60"/1500 in a variety of straight and reducing styles. Most standard fittings are cast of durable
More informationSection 8 AMERICAN. Flanged Pipe
Section 8 AMERICAN Flanged Pipe The principal standards covering Flanged Pipe are ANSI/AWWA C115/A21.15 and ANSI/AWWA C110/A21.10. These and other standards are referenced throughout this Section either
More informationSECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS
SECTION 22 11 23.13 (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Packaged Domestic Water Booster Pumps B. Related Sections: 1.02 REFERENCES 1. Section
More informationGrooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 60"/1500 in a variety of straight and reducing styles. Most standard fittings are cast of durable
More informationTECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)
January 13, 2006 Deluge Valves 211 a 1. PRODUCT NAME Viking Model E-1 Deluge Valve 3 (DN80) Available since 1985 4 (DN100) Available since 1985 6 (DN150) Available since 1984 2. MANUFACTURER THE VIKING
More informationA. This Section includes natural gas piping, specialties, and accessories within the building.
SECTION 226313 NATURAL GAS PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and C-to-C dimension. C - C LOAD lb.
Fig. 2110 www.pipingtech.com/fig2110 Sway Strut with 4 of Adjustment Engineered spring supports option 1 option 2 ORDERING: Specify size, figure number, description, nominal pipe size or special O.D. and
More informationInstallation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA
LSSN Butterfly Valve Installation Operation Maintenance Licence Number: 5326 www.challengervalves.com.au 1 Index 1. INTRODUCTION 1.1 Design Features 3 1.2 Flange and Pipe Compatibility 4 1.3 Operating
More informationSTANDARD PIPE CLAMP FIG. 520 & 521
Designed to be used in the suspension of non-insulated pipe lines. Normally used in conjunction with Fig. 35 weldless eye nut, Fig. 50 eye rod or Fig. 55 welded eye rod to allow flexibility at the rod
More informationListings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5
Model Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Features Flat concealed cover plate available solid
More informationValve Selection. 1. Function and service considerations
1. Function and service considerations Valve Selection Selection Valves serve the purpose of controlling the fluids in building services piping. Valves are produced in a variety of design types and materials.
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 23 2123 - PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationPressfit System for Carbon Steel Pipe
R PRESSFIT SYSTEM FOR ARBON STEEL PIPE Pressfit System for arbon Steel Pipe 12.02 VITALI IS AN ISO 9001 ERTIFIED OMPANY PRODT DESRIPTION L FM L See Victaulic publication 10.01 for details. The Pressfit
More informationFord Service Saddles and Tapping Sleeves
Section AA 04/2013; web revision 02/2014 Ford Service Saddles and Tapping Sleeves The Ford Meter Box Company, Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260-563-3171
More informationI-234. Victaulic Styles 234/234S Restrained, Flexible Single-Gasket Couplings WARNING IMPORTANT INFORMATION ITEMS PROVIDED WITH SHIPMENT:
WARNING Read and understand all instructions before attempting to install any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic
More information08.08 Vic-Check Valves
The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc
More informationMACRO HP. NEW SMALLER SIZES Macro HP is Now Available for 2-12 inch Pipe Sizes. patent number:
ACROMACROMACROMA MACRO HP ROMAC S SECOND GENERATION TWO-BOLT E X T E N D E D R A N G E C O U P L I N G NEW SMALLER SIZES Macro HP is Now Available for 2-12 inch Pipe Sizes patent number: 8448993 BMACROHP
More informationPipe Repair Products. A complete selection for all types of pipe
Pipe Repair Products A complete selection for all types of pipe Mueller Service Saddles Manufactured and tested in accordance with ANSI/AWWA C800 & NSF 61 certified. Mueller service saddles, available
More informationSJ-300N J-04. Model SJ-300N-L Butterfly Valve with Lever Handle
SJ-300N J-04 MODEL SJ-300N BUTTERFLY VALVE The Model SJ-300N Butterfly Valve is a grooved-end tight shut-off valve designed, manufactured and tested to MSS SP-67. The valve can be shipped either with a
More informationGBV-G Balancing Valves
Ductile Iron ASTM A6, Grade 6-4-2 The Series GBV is a multi-turn, Y-style globe valve designed for accurate determination and control of fluid flow to circuits requiring precise balancing. Max. Working
More informationK81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS
GUARDIAN K81-D FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J L M K N P Q S R
More information[INCH-POUND] A-A December 1999 SUPERSEDING MIL-C-4109F 31 October 1986
[INCH-POUND] 30 December 1999 SUPERSEDING MIL-C-4109F 31 October 1986 COMMERCIAL ITEM DESCRIPTION COUPLING HALVES, QUICK-DISCONNECT The General Services Administration has authorized the use of this commercial
More information