2011 Ver Ph: Product Catalogue. Industrial Cables Hazardous area equipment Cable termination

Size: px
Start display at page:

Download "2011 Ver Ph: Product Catalogue. Industrial Cables Hazardous area equipment Cable termination"

Transcription

1 2011 Ver 1.1 Product Catalogue Industrial Cables Hazardous area equipment Cable termination

2 KabEx Australia is a leading company specializing in the supply of cables, hazardous area equipment and associated goods. By bringing together the best of relationships with both overseas factories and local suppliers KabEx offers a complete range of cables with particular emphasis on flexible power cables, instrumentation cables, low and medium voltage cables. We offer a custom manufacture service to meet any specification of specialty cables with very competitive pricing which includes fast lead times and low minimum order quantities. KabEx Australia is also the sole Australian importer of OSCG cable glands and accessories for both Hazardous & Industrial Area. Our extensive experience includes exporting to major projects throughout the Asia, Pacific and Middle East regions. We also offer nationwide coverage with particular strengths in servicing the entire Eastern Seaboard of Australia and remote areas. All products supplied by KabEx meet our strict quality criteria and are made to the highest standard in ISO9001 certified factories.

3 Contents Instrumentation Cable 2-10 Overall Screened Pairs 3 Ind & Overall Screened Pairs 4 Overall Screened SWA Pairs 5 Ind & Overall Screened SWA Pairs 6 Overall Screened Triples 7 Ind & Overall Screened Triples 8 Overall Screened SWA Triples 9 Ind & Overall Screened SWA Triples 10 Flexible Cables PVC Clear Sheath Flexible EMC Cable 11 XLPE Insulated, UV Stabalised, Flexible EMC Cable 12 PVC Flexible Control Cable 14 Flexible Cables Rubber Single Core 110Deg 3.3kV Flexible 18 Ozoflex Rubber 20 Hi Temperature Halogen Free Single Core 125Deg Flexible 24 Sinotherm High Temperature Cables 26 Siemens Speciality Cables 29 OSCG Hazardous & Industrial Area OSGP Hazardous Area Enclosures 30 OSNJA2F Hazardous Gland for Unarmoured Cables 31 OSSP Hazardous Area Stopping Plug 32 OSRA Hazardous Area Reducer 33 OSAJ Hazardous Area Adaptor 34 OSAE Hazardous Area Elbow 35 OSNJ Industrial Metal Cable Gland 36 OSNJ-CW Industrial Gland for SWA Cables 37 OSPG PG Thread Cable Glands 38 Earth Tags, Lock Nuts, Washers 39 Cable Termination Accessories Stainless Steel Cable Tie 40 Nylon Cable Tie 41 Nylon Cable Gland, Slotted Duct 42 Bootlace Ferruls 43 Copper Lugs, Bellmouth Lugs, Crimp Links 44 K Type Cable Markers 46

4 INSTRUMENTATION CABLE APPLICATION Used in data processing and process control. Suitable for fixed installations in damp locations and open spaces. The electrostatic screen protects against outer interference fields. Design LSZH (Low Smoke Zero Halogen) Instrumentation cable consisting of bare copper conductors, black & white twisted pairs or black, white & red twisted triples with continuous number sequence. Cables are manufactured strictly in accordance of UL as well as relevant Australian Standards. Voltage Rating Rated Voltage Max. 300V a.c Nominal Voltage A.C/D.C 110/150V Test Voltage In process spark test 4500V and AC withstand voltage test 1500V Technical Data 0.5mm 1.5mm Maximum Capacitance to 145pF/m 200pF/m to Screen 240pF/m 300pF/m Maximum 20 C 38.4Ω/km 13.8Ω/km Insulation 20 C 40MΩ/km 140MΩ/km Cross Talk Attentuation Between 1kHz 300Ω 150Ω 1kHz 1.00mH/km 0.95mH/km L/R 1kHz 13.7µH/Ω 36.5µH/Ω Operating Temperature Minimum continuous operating temperature -25 C Maximum continuous operating temperature 75 C Maximum conductor operating temperature 90 C Minimum short circuit temperature 160 C (for 5 sec) Bending Radii The following minimum bending radius should be observed to ensure operating reliability Unarmoured: 9 x cable outer (during installation) 6 x cable outer (after installation) Armoured: 18 x cable outer (during installation) 12 x cable outer (after installation) Tensile Strength Cable maximum pulling tension (approximate) is limited to N/mm² of the total cross-sectional area of conductor. Example: 3pairs 1.5 total cross sectional area 3x 2x1.5=9mm² 9mm² x 70Nmm² =630N (0.63kn) For pulling by armour, the pulling tension should be limited to 130 N/mm² of the total cross-sectional of steel wire. 2

5 INSTRUMENTATION CABLE Overall Screened Cable LSZH Construction consisting of: Bare copper conductors to AS1125 Flame retardant FR-V90 Insulation to UL style 1569 Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Black outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail) 0.5mm² Part No Pairs No/Dia Insulation thickness Nom. Overall 20c Ohm/km Approximate weight (kg/km) 0.5MM1PR 1 7/ MM2PR 2 7/ MM3PR 3 7/ MM4PR 4 7/ MM6PR 6 7/ MM8PR 8 7/ MM10PR 10 7/ MM12PR 12 7/ MM16PR 16 7/ MM20PR 20 7/ MM24PR 24 7/ MM36PR 36 7/ Intrinsically Safe version add BLUE to part number 1.5mm² Part No Pairs No/Dia Insulation thickness Overall 20c Ohm/km Approximate weight (kg/km) 1.5MM1PR 1 7/ MM2PR 2 7/ MM3PR 3 7/ MM4PR 4 7/ MM6PR 6 7/ MM8PR 8 7/ MM10PR 10 7/ MM12PR 12 7/ MM16PR 16 7/ MM20PR 20 7/ MM24PR 24 7/ MM36PR 36 7/ Intrinsically Safe version add BLUE to part number 3

6 INSTRUMENTATION CABLE Individual & Overall Screened Cable LSZH Construction consisting of: Bare copper conductors to AS1125 Flame retardant FR-V90 Insulation to UL style 1569 Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Black outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail) 0.5mm² Part No Pairs No/Dia Insulation thickness Nom. Overall 20c Ohm/km Approximate weight (kg/km) 0.5MM2PRES 2 7/ MM4PRES 4 7/ MM6PRES 6 7/ MM8PRES 8 7/ MM10PRES 10 7/ MM12PRES 12 7/ MM16PRES 16 7/ MM20PRES 20 7/ MM24PRES 24 7/ MM36PRES 36 7/ Intrinsically Safe version add BLUE to part number 4 1.5mm² Part No Pairs No/Dia Insulation thickness Nom. Overall 20c Ohm/km Approximate weight (kg/km) 1.5MM2PRES 2 7/ MM4PRES 4 7/ MM6PRES 6 7/ MM8PRES 8 7/ MM10PRES 10 7/ MM12PRES 12 7/ MM16PRES 16 7/ MM20PRES 20 7/ MM24PRES 24 7/ MM36PRES 36 7/ Intrinsically Safe version add BLUE to part number

7 INSTRUMENTATION CABLE Overall Screened SWA Cable LSZH Construction consisting of: Bare copper conductors to AS1125 Flame retardant FR-V90 Insulation to UL style 1569 Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Black flame retardant FR-V90 inner sheath to UL style 2464 Steel wire armour Black outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail) 0.5mm² Part No Pairs No/Dia Insulation thickness Overall over bedding Steel wire Amour Overall over armour Overall 20c Ohm/km Approximate weight (kg/ km) 0.5MM1PRSWA 1 7/ MM2PRSWA 2 7/ MM4PRSWA 4 7/ MM6PRSWA 6 7/ MM8PRSWA 8 7/ MM10PRSWA 10 7/ MM12PRSWA 12 7/ MM16PRSWA 16 7/ MM20PRSWA 20 7/ MM24PRSWA 24 7/ MM36PRSWA 36 7/ Intrinsically Safe version add BLUE to part number 1.5mm² Part No Pairs No/Dia Insulation thickness Overall over bedding Steel wire Amour Overall over armour Overall 20c Ohm/km Approximate weight (kg/ km) 1.5MM1PRSWA 1 7/ MM2PRSWA 2 7/ MM4PRSWA 4 7/ MM6PRSWA 6 7/ MM8PRSWA 8 7/ MM10PRSWA 10 7/ MM12PRSWA 12 7/ MM16PRSWA 16 7/ MM20PRSWA 20 7/ MM24PRSWA 24 7/ MM36PRSWA 36 7/ Intrinsically Safe version add BLUE to part number 5

8 INSTRUMENTATION CABLE Individual & Overall Screened SWA Cable LSZH CONsTRuCTION CONsIsTINg Of: Bare copper conductors to AS1125 Flame retardant FR-V90 Insulation to UL style 1569 Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Black flame retardant FR-V90 inner sheath to UL style 2464 Steel wire armour Black outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail) 0.5mm² Part No. Pairs No/Dia Insulation thickness Overall over bedding steel wire Amour Overall over armour Overall 20c Ohm/km Approximate weight (kg/ km) 0.5MM2PRSWAES 2 7/ MM4PRSWAES 4 7/ MM6PRSWAES 6 7/ MM8PRSWAES 8 7/ MM10PRSWAES 10 7/ MM12PRSWAES 12 7/ MM16PRSWAES 16 7/ MM20PRSWAES 20 7/ MM24PRSWAES 24 7/ MM36PRSWAES 36 7/ Intrinsically safe version add BLue to part number 6 1.5mm² Part No. Pairs No/Dia Insulation thickness Overall over bedding steel wire Amour Overall over armour Overall 20c Ohm/km Approximate weight (kg/ km) 1.5MM2PRSWAES 2 7/ MM4PRSWAES 4 7/ MM6PRSWAES 6 7/ MM8PRSWAES 8 7/ MM10PRSWAES 10 7/ MM12PRSWAES 12 7/ MM16PRSWAES 16 7/ MM20PRSWAES 20 7/ MM24PRSWAES 24 7/ MM36PRSWAES 36 7/ Intrinsically safe version add BLue to part number

9 INSTRUMENTATION CABLE Overall Screened Triad Cable LSZH Construction consisting of: Bare copper conductors to AS1125 Flame retardant FR-V90 Insulation to UL style 1569 Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Black outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail) 0.5mm² Part No Triples No/Dia Insulation thickness Nom. Overall 20c Ohm/km Approximate weight (kg/km) 0.5MM1TR 1 7/ MM2TR 2 7/ MM3TR 3 7/ MM4TR 4 7/ MM6TR 6 7/ MM8TR 8 7/ MM10TR 10 7/ MM12TR 12 7/ MM16TR 16 7/ MM20TR 20 7/ MM24TR 24 7/ MM36TR 36 7/ Intrinsically Safe version add BLUE to part number 1.5mm² Part No Triples No/Dia Insulation thickness Nom. Overall 20c Ohm/km Approximate weight (kg/km) 1.5MM1TR 1 7/ MM2TR 2 7/ MM3TR 3 7/ MM4TR 4 7/ MM6TR 6 7/ MM8TR 8 7/ MM10TR 10 7/ MM12TR 12 7/ MM16TR 16 7/ MM20TR 20 7/ MM24TR 24 7/ MM36TR 36 7/ Intrinsically Safe version add BLUE to part number 7

10 INSTRUMENTATION CABLE Individual & Overall Screened Triad Cable LSZH Construction consisting of: Bare copper conductors to AS1125 Flame retardant FR-V90 Insulation to UL style 1569 Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Black outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail) 0.5mm² Part No Triples No/Dia Insulation thickness Nom. Overall 20c Ohm/km Approximate weight (kg/km) 0.5MM2TRES 2 7/ MM3TRES 3 7/ MM4TRES 4 7/ MM6TRES 6 7/ MM8TRES 8 7/ MM10TRES 10 7/ MM12TRES 12 7/ MM16TRES 16 7/ MM20TRES 20 7/ MM24TRES 24 7/ MM36TRES 36 7/ Intrinsically Safe version add BLUE to part number 8 1.5mm² Part No Triples No/Dia Insulation thickness Nom. Overall 20c Ohm/km Approximate weight (kg/km) 1.5MM2TRES 2 7/ MM3TRES 3 7/ MM4TRES 4 7/ MM6TRES 6 7/ MM8TRES 8 7/ MM10TRES 10 7/ MM12TRES 12 7/ MM16TRES 16 7/ MM20TRES 20 7/ MM24TRES 24 7/ MM36TRES 36 7/ Intrinsically Safe version add BLUE to part number

11 INSTRUMENTATION CABLE Overall Screened SWA Triad Cable LSZH Construction consisting of: Bare copper conductors to AS1125 Flame retardant FR-V90 Insulation to UL style 1569 Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Black flame retardant FR-V90 inner sheath to UL style 2464 Steel wire armour Black outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail) 0.5mm² Part No Triples No/Dia Insulation thickness Overall over bedding Steel wire Amour Overall over armour Overall 20c Ohm/km Approximate weight (kg/ km) 0.5MM1TRSWA 1 7/ MM2TRSWA 2 7/ MM3TRSWA 3 7/ MM4TRSWA 4 7/ MM6TRSWA 6 7/ MM8TRSWA 8 7/ MM10TRSWA 10 7/ MM12TRSWA 12 7/ MM16TRSWA 16 7/ MM20TRSWA 20 7/ MM24TRSWA 24 7/ MM36TRSWA 36 7/ Intrinsically Safe version add BLUE to part number 1.5mm² Part No Triples No/Dia Insulation thickness Overall over bedding Steel wire Amour Overall over armour Overall 20c Ohm/km Approximate weight (kg/ km) 1.5MM1TRSWA 1 7/ MM2TRSWA 2 7/ MM3TRSWA 3 7/ MM4TRSWA 4 7/ MM6TRSWA 6 7/ MM8TRSWA 8 7/ MM10TRSWA 10 7/ MM12TRSWA 12 7/ MM16TRSWA 16 7/ MM20TRSWA 20 7/ MM24TRSWA 24 7/ MM36TRSWA 36 7/ Intrinsically Safe version add BLUE to part number 9

12 INSTRUMENTATION CABLE Individual & Overall Screened SWA Triad Cable LSZH Construction consisting of: Bare copper conductors to AS1125 Flame retardant FR-V90 Insulation to UL style 1569 Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire Black flame retardant FR-V90 inner sheath to UL style 2464 Steel wire armour Black outer sheath with flame retardant V90 LSZH UL style 2462 (Blue Intrinsically Safe option avail) 0.5mm² Part No Triples No/Dia Insulation thickness Overall over bedding Steel wire Amour Overall over armour Overall 20c Ohm/km Approximate weight (kg/ km) 0.5MM2TRSWAES 2 7/ MM3TRSWAES 3 7/ MM4TRSWAES 4 7/ MM6TRSWAES 6 7/ MM8TRSWAES 8 7/ MM10TRSWAES 10 7/ MM12TRSWAES 12 7/ MM16TRSWAES 16 7/ MM20TRSWAES 20 7/ MM24TRSWAES 24 7/ MM36TRSWAES 36 7/ Intrinsically Safe version add BLUE to part number 1.5mm² Part No Triples No/Dia 10 Insulation thickness Overall over bedding Steel wire Amour Overall over armour Overall 20c Ohm/km Approximate weight (kg/ km) 1.5MM2TRSWAES 2 7/ MM3TRSWAES 3 7/ MM4TRSWAES 4 7/ MM6TRSWAES 6 7/ MM8TRSWAES 8 7/ MM10TRSWAES 10 7/ MM12TRSWAES 12 7/ MM16TRSWAES 16 7/ MM20TRSWAES 20 7/ MM24TRSWAES 24 7/ MM36TRSWAES 36 7/ Intrinsically Safe version add BLUE to part number

13 PROTOFLEX EMC Clear sheath EMC cable APPLICATION Specifically designed low capacitance screened cable for connection between AC variable speed drives and motors. Suitable for fixed installation and occasional freely flexing applications in dry damp and wet conditions. DESIGN Electromagnetic compatibility (EMC) is the ability of electrical or electronic equipment to function normally in an environment without being affected by electromagnetic (EMI) and radio frequency interferences (RFI) or in turn disturbing the environment by transmitting EMI or RFI. VOLTAGE RATING Rated AC voltage: Uo/U = 0.6kV/1kV Selection and ordering data No. of cores x size Part No. Approx. No. of strands x Max. strand Nominal over screen Max outer Min bending radii fixed Min bending radii flexing Net weight Unenclosed Touching mm² mm mm mm mm mm kg/km A 3 x 1.5 5EMC x x 2.5 5EMC x x 1.5 5EMC x x 2.5 5EMC x x 4 5EMC x x x 1.5 5EMC x x x 1.5 5EMC x x x 2.5 5EMC x x x 4 5EMC x * For larger conductor sizes, refer Protoflex - EMV - FC 11

14 PROTOFLEX - EMV - FC XLPE insulated, UV stabalised EMC Cable APPLICATION Specifically designed low capacitance screened cable for connection between AC variable speed drives and motors. Suitable for fixed installation and occasional freely flexing applications in dry damp and wet conditions. U.V stabilised for outdoor use. Not suitable for direct installation into the ground or submersion in water. DesIgN Electromagnetic compatibility (EMC) is the ability of electrical or electronic equipment to function normally in an environment without being effected by (EMI) electromagnetic and (RFI) radio frequency interferences or in turn disturbing the environment by transmitting EMI or RFI. The Siemens PROTOFLEX -EMV screened power cable consists of finely stranded copper conductors with Cross Linked Poly Ethylene (XLPE) insulation covered with a tinned copper braided screen and a PVC orange, transparent sheath. For cable cross sections 16mm² or greater the earth conductor is divided evenly into 3 seperate cores and uniformally located in the intersticial gaps around the power cores. This achieves a truly concentric design in accordance with the EMC standards. The overall tinned copper braid screen is specifically designed for optimum Electromagnetic Compatibility (EMC) by taking into account the percentage coverage, braid fan angle, and wire gauge which all results in a very low transfer resistance. The screen offers a low DC resistance affording protection from low frequency interference such as AC harmonics. The cable is in accordance with AS 1125 for the conductors and AS 1347 for the sheath. Fire performance is according to IEC OPERATING TEMPERATURE Minimum permissible ambient temperature -40 C Maximum permissible conductor temperature 90 C Maximum permissible short circuit temperature 250 C Minimum ambient temperature for optimum fully flexible operation -5 C CuRReNT CARRYINg CAPACITY Current ratings are based on continuous operation at an ambient temperature of 40 C. At other temperatures these values must be converted using the following table. C Factor minimum BeNDINg RADII For recommended bending radii refer to the selection and ordering data tables. CORe COLOuR IDeNTIfICATION 4 core - brown, blue, black, green/yellow VOLTAge RATINg Rated AC voltage: Uo/U = 0.6kV/1kV Rated DC voltage: Uo/U = 0.9/1.8kV AC test voltage: = 5kV 12

15 PROTOFLEX - EMV - FC XLPE insulated, UV stabalised EMC Cable Selection and ordering data No. of cores and conductor rated cross-section Part No. design approx. No. of strands x Max. strand Operating capacitance Nominal over screen Max outer Min bending radii fixed Min bending radii flexing Net weight Unenclosed Touching mm² mm nf/km mm mm mm mm kg/km A 4 x 1.5 5DE x x 2.5 5DE x x 4 5DE x x 6 5DE x x 10 5DE x x x 2.5 5DE x x x 4 5DE x x x 16/3 5DE x x x 25/3 5DE x x x 35/3 5DE x x x 50/3 5DE x x x 50/3 5DE x x x 70/3 5DE x x x 95/3 5DE x x x 120/3 5DE x x x 150/3 5DE x

16 PROTOFLEX PVC PVC control cables APPLICATION PROTOFLEX PVC control cables are specially suitable for use as flexible control cables. Fans and air-conditioning systems Machine tools Production and processing machines Industrial robots DESIGN PROTOFLEX PVC control cables consist of finely stranded copper conductors with V75 PVC insulation. The high grade PVC sheath is resistant to oil, grease and chemicals. Designed for moderate mechanical loading, in dry, damp and wet areas and in hazardous areas. Outdoor use is possible, provided that the cables are protected from direct sunlight and are permanently installed. SPECIAL FEATURES Suitable for use Burning behavior in accordance with DIN in hazardous areas VDE 0472 Part 804, Test B (IEC 332-1) Voltages 300/500 V Rated voltage 318/550 V HIghest permissible operating voltage - 3 phase and single phase operation - in DC operation 2 kv Test voltage Certifi cation VDE Reg. No Standards Based on DIN VDE TECHNICAL INFORMATION Cable construction is based on DIN VDE Finely-stranded bare copper conductors according to VDE 0295 Class 5 Insulation of special polyvinyl chloride (PVC) PVC inner sheath over laid-up cores in shielded versions Grey PVC outer sheath, largely resistant to oil and chemicals CONTINUOUS TENSILE LOAD The maximum allowable tensile stress for operation of cables with mobile equipment is 15 N per mm². The maximum allowable tensile stress is 50 N mm² for fixed installations. PERMISSIBLE TEMPERATURE At conductor: free-flexing +5 C to + 70 C fixed - 40 C to + 70 C Bending radii: fixed 4 d free-flexing 7.5 d d= outer of cable CURRENT CARRYING CAPACITY The current carrying capacities are based on a continuous operating temperature of 40 C. At other temperatures these values must be converted using the following factors C Factor VOLTAGE RATING Rated voltage:: Uo/U = 300/500V AC test voltage: = 2kV *The cable is designated 300/500V in accordance with VDE/IEC and meets the Australian standard for the stated voltage rating AS 1125, AS CORE COLOUR IDENTIFICATION All control cores are black, sequentially numbered and include a green/yellow earth core. 14

17 PROTOFLEX PVC PVC control cables Selection and ordering data No. of cores x cross-section Part No. Approx. No. of strands x Max. strand Cable overall Unenclosed Touching mm² mm mm A 2 x 0.5 5DE x x 0.5 5DE x x 0.5 5DE x x 0.5 5DE x x 0.5 5DE x x 0.5 5DE x x 0.5 5DE x x 0.5 5DE x x 0.5 5DE x x 0.5 5DE x x 0.5 5DE x No. of cores x cross-section Part No. Approx. No. of strands x Max. strand Cable overall Unenclosed Touching mm² mm mm A 2 x DE x x DE x x DE x x DE x x DE x x DE x x DE x x DE x x DE x x DE x x DE x

18 PROTOFLEX PVC PVC control cables Selection and ordering data No. of cores x cross-section Part No. Approx. No. of strands x Max. strand Cable overall Unenclosed Touching mm² mm mm A 2 x 1.0 5DE x x 1.0 5DE x x 1.0 5DE x x 1.0 5DE x x 1.0 5DE x x 1.0 5DE x x 1.0 5DE x x 1.0 5DE x x 1.0 5DE x x 1.0 5DE x x 1.0 5DE x No. of cores x cross-section Part No. Approx. No. of strands x Max. strand Cable overall Unenclosed Touching 16 mm² mm mm A 2 x 1.5 5DE x x 1.5 5DE x x 1.5 5DE x x 1.5 5DE x x 1.5 5DE x x 1.5 5DE x x 1.5 5DE x x 1.5 5DE x x 1.5 5DE x x 1.5 5DE x x 1.5 5DE x

19 PROTOFLEX PVC PVC control cables Selection and ordering data No. of cores x cross-section Part No. Approx. No. of strands x Max. strand Cable overall Unenclosed Touching mm² mm mm A 2 x 2.5 5DE x x 2.5 5DE x x 2.5 5DE x x 2.5 5DE x x 2.5 5DE x x 2.5 5DE x x 2.5 5DE x x 2.5 5DE x x 2.5 5DE x x 2.5 5DE x

20 SINGLE CORE 3.3kV 110 FLEX Highly flexible, single core rubber cables APPLICATION Internal switchboard cabling Sub-mains Electrical traction vehicles Battery bank connections Machine & equipment cabling Steelworks, cranes & hoists Stacker & reclaimer cabling DC wiring 415/ 1000V installations Submersible to 100 metres DESIGN lsingle core 3.3kV flex cables consist of extra finely stranded tinned copper conductors laid up to provide an extremely flexible design. The Protolon R-EP-110 elastomer insulation is rated at 3.3kV with an oil resistant, flame retardant PCP sheath completing the construction. The cable is in accordance with AS1125, AS3116 and VDE0250 part 602. for NSGAFoeu. Permissable thermal short-circuit currents for 1 s duration (conductor temperature at start of short-circuit: 110 C): [mm²] [ka] Permissible short-circuit currents for other durations are available. The thermal as well as the dynamic short-circuit strength must be taken into account. The cables must in particular be firmly fixed to protect them from the effects of peak short-circuit currents. OPERATING TEMPERATURE Minimum permissible ambient temperature -40 C Maximum permissible conductor temperature 110 C Maximum permissible short circuit temperature 250 C Minimum ambient temperature for optimum fully flexible operation -25 C MINIMUM BENDING RADII The following minimum bending radii should be observed to ensure operating reliability. For fixed installation 6 x cable When freely flexing 8 x cable CURRENT CARRYING CAPACITY Current ratings are based on continuous operation at an ambient temperature of 40 C. At other temperatures these values must be converted using the following table. C Factor Current ratings are based on AS/NZS :1998. Table 8 Current- Carrying Capacities of Three Single-Core 0.6/1kV Sheathed and Unsheathed non-armoured cables R-E-110 TENSILE STRENGTH The maximum allowable tensile stress is 15N/mm². This ensures no conductor damage will occur in operation. VOLTAGE RATING Rated voltage: 0.6/1kV to 3.3kV AC Maximum operating voltages in: 3 phase AC operation Uo/U = 2.1/3.6kV DC operation Uo/U = 2.7/5.4kV AC test voltage = 6kV CURRENT CARRYING CAPACITY The core insulation is white. 18

21 SINGLE CORE 3.3kV 110 FLEX Highly flexible, single core rubber cables Selection and ordering data No. of cores x conductor Part No. Approx No. of strand x Max. of bare conductor stand Cable overall Cable weight Current carrying capacity when installed Unenclosed Spaced Unenclosed Spaced from Unenclosed Touching Enclosed surface Min Max mm² mm mm mm mm kg/km A A A A 1x1.5 5DF x x2.5 5DF x x 4 5DF x x 6 5DF x x 10 5DF x x 16 5DF x x 25 5DF x x 35 5DF x x 50 5DF x x 70 5DF x x 95 5DF x x 120 5DF x x 150 5DF x x 185 5DF x x 240 5DF x x 300 5DF x x 400 5DF x

22 OZOFLEX Heavy duty EPR/CSP rubber flexible cables APPLICATION Heavy duty construction site leads for drills, pumps, saws, kangos Cranes, hoists & festoon systems Stage & theatre power & lighting Portable motors, generators & power supplies Submersible to 100 metres plus DesIgN OZOFLEX is designed as a heavy duty flexible for dry, damp and wet environments, areas of stress caused by vibration or impact and is resistant to abrasion, exposure to radiated heat and chemical contamination. Because of the black, flame retardant CSP sheath OZOFLEX is suitable for areas subject to fire hazard and hazardous locations. OZOFLEX cables consist of finely stranded copper conductors laid up to provide a flexible design. R-EP-90 elastomer insulation provides improved current capacities. Cables above 16mm² and all control cables have an elastomer inner sheath. The CSP elastomer sheath (Hypalon) is oil resistant and flame retardant in accordance with VDE The construction is in accordance with the Australian Standards AS 1125, AS 3191, AS 3116 and DIN/VDE 0282 IEC332-1 and CENELEC standards for O7RN. When installed on spring operated reelers the following de-rating factors are to be applied: 1 layer on real layers layers 0.49 VOLTAge RATINg Rated voltage: Uo/U = 0.6/1kV Maximum operating voltages in: 3 phase AC operation Uo/U = 0.7/1.15kV DC operation Uo/U = 0.9/1.73kV AC test voltage = 2.5kV *The cable is designated 450/750V with EI1 insulation compound in accordance with VDE/IEC and meets or exceeds the Australian Standard AS 3116 for the voltage rating of 0.6/1kV, R-EP-90. CORe COLOuR IDeNTIfICATION Single Core black 3 Core blue, brown, green/yellow 4 Core brown, black, green/yellow, grey 5 Core blue, brown, black, green/yellow, grey Multi core black insulation sequentially numbered including a green/yellow earth core. TeNsILe strength The maximum allowable tensile stress is 15N/mm2. This ensures no conductor damage will occur in operation. OZOFLEX cables, covered by the Prescribed Items Act mandatory approval for flexible leads, are accordingly covered by Approval Certificate No OPeRATINg TemPeRATuRe Minimum permissible ambient temperature -40 C Maximum permissible short circuit temperature 250 C Minimum ambient temperature for optimum fully flexible operation -25 C minimum BeNDINg RADII The following minimum bending radii should be observed to ensure operating reliability. For fixed installation 4 x cable When freely flexing 5 x cable CuRReNT CARRYINg CAPACITY Current ratings are based on continuous operation at an ambient temperature of 40 C. At other temperatures these values must be converted using the following table. C Factor

23 OZOFLEX Heavy duty EPR/CSP rubber flexible cables Selection and ordering data Number of Cores x Size Part No. Approx. No of Strands x Max. Strand of bare conductor Cable Overall Cable Weight Unenclosed Touch mm² mm mm Min mm Max mm kg/km A Without a Green/ Yellow earth 2 x 1.5 5DH x x 2.5 5DH x x 4 5DH x OZOFLEX including a green/yellow earth core 3G1 5DH x G1.5 5DH x G2.5 5DH x G4 5DH x G6 5DH x G10 5DH x G16 5DH x G1 5DH x G1.5 5DH x G2.5 5DH x G4 5DH x OZOFLEX Aust. Core Colours R,W,B,B,G/Y 5G2.5 5DH x G4 5DH x G6 5DH x G10 5DH x G16 5DH x G25 5DH x G35 5DH x OZOFLEX including a green/yellow earth core 7G1.5 5DH x G1.5 5DH x G1.5 5DH x G2.5 5DH x G2.5 5DH x G2.5 5DH x G2.5 5DH x G2.5 5DH x

24 OZOFLEX (PLUS) Flexible cables for submersion in polluted liquids APPLICATION Sewage treatment plants Waste water pumps - effluent aerators Abattoirs (high temp chemical cleaning) Dairy industry Mining - de-watering Chemical plants & steelworks Hygenic cleaning in breweries, food processing plants etc. Water depth approx. 10m in waste water, up to 500m in all other types DesIgN OZOFLEX (PLUS) cables consist of finely stranded copper conductors laid up to provide a flexible design. R-EP-90 elastomer insulation provides improved current capacities. Cables above 16mm2 and all control cables include an additional elastomer inner sheath and all cables up to 6mm2 have tinned conductors. The specially compounded heavy duty CPE Elastomer sheath (Hypalon) is oil resistant and flame retardant and resists the effects of water absorption. compound in accordance with VDE/IEC and meets or exceeds the Australian Standard AS 3116 for the voltage rating of 0.6/1kV, R-EP-90. CORe COLOuR IDeNTIfICATION Single Core black 3 Core blue, brown, green/yellow 4 Core brown, black, green/yellow, grey 5 Core blue, brown, black, green/yellow, grey Multi core black insulation sequentially numbered including a green/yellow earth core. TeNsILe strength The maximum allowable tensile stress is 15N/mm². This ensures no conductor damage will occur in operation. The construction is in accordance with the Australian Standards AS 1125, AS 3191, AS 3116 and DIN/VDE 282 and CENELEC STANDARDS for 07RN, IEC OPeRATINg TemPeRATuRe Minimum permissible ambient temperature -40 C Maximum permissible short circuit temperature 250 C Minimum ambient temperature for optimum fully flexible operation -25 C minimum BeNDINg RADII The following minimum bending radii should be observed to ensure operating reliability. For fixed installation 4 x cable When freely flexing 5 x cable CuRReNT CARRYINg CAPACITY Current ratings are based on continuous operation at an ambient temperature of 40 C. At other temperatures these values must be converted using the following table. C Factor VOLTAge RATINg Rated voltage: Uo/U = 0.6/1kV Maximum operating voltages in: 3 phase AC operation Uo/U = 0.7/1.15kV DC operation Uo/U = 0.9/1.73kV AC test voltage = 2.5kV * The cable is designated 450/750V with EI1 insulation 22

25 OZOFLEX (PLUS) Flexible cables for submersion in polluted liquids Selection and ordering data OZOFLEX (PLUS) including a green/ yellow earth core OZOFLEX (PLUS) with pilots Number of Cores x Size Part No. Approx. No of Strands x Max. Strand of bare conductor Cable Overall Cable Weight Unenclosed Touch mm² mm mm Min mm Max mm kg/km A 4G1.5 5DH x G2.5 5DH x G4 5DH x G6 5DH x G10 5DH x G16 5DH x G25 5DH x G35 5DH x G50 5DH x G70 5DH x G95 5DH x G120 5DH x G x 1.5 5DH x G x 1.5 5DH x G4 + 2 x 1.5 5DH x G6 + 2 x 1.5 5DH x G x 1.5 5DH x G x 1.5 5DH x G x 1.5 5DH x G x 1.5 5DH x

26 EVA 125 FLEX High temperature 125 c flame retardant halogen free flexible cables APPLICATION Switchboard cabling Coil & transformer wiring High thermal stress resistant Chemical & ceramic industry Steelworks DesIgN EVA 125 is a flexible elastomer insulated cable with improved thermal characteristics due to special cross linking together with an excellent resistance to oils, chemicals, abrasion and mechanical damage. EVA 125 Flex cables consist of finely stranded tinned copper conductors laid up to provide a flexible design with a specially compounded R-EVA-125 synthetic rubber insulation for operation in elevated ambient temperatures. The cable is in accordance with the Australian Standards AS 1125, AS/NZS and DIN VDE 0282 pt 501 for H07G The special Ethylene Vinyl Acetate compound is halogen free and exhibits low smoke generation in the event of fire and has a high resistance to absorption of oils and grease. OPeRATINg TemPeRATuRe Minimum and maximum permissible ambient temperature -40 C to +110 C Maximum permissible conductor temperature 120 C Maximum permissible short circuit temperature 250 C minimum BeNDINg RADII The following minimum recommended bending radii should be observed to ensure operating reliability. For fixed installation 4 x cable When freely flexing 5 x cable CuRReNT CARRYINg CAPACITY Current ratings are based on a continuous operating ambient temperature of 40 C. At other temperatures these values must be converted using the following table. C Factor TeNsILe strength The maximum allowable tensile stress on the conductors is 15N/mm². This ensures no conductor damage will occur in operation. VOLTAge RATINg Rated voltage:: Uo/U = 0.6/1kV Maximum operating voltages in: 3 phase AC operation Uo/U = 0.7/1.15kV DC operation Uo/U = 0.9/1.73kV AC test voltage:: Uo/U = 2.5kV The cable is designated 450/750V in accordance with VDE/IEC and meets or exceeds the Australian Standard AS3116 for the voltage rating 0.6/1kV CORe COLOuR IDeNTIfICATION The cable is available in either black or orange as standard. Variations are available subject to manufacture length. 24

27 EVA 125 FLEX High temperature 125 c flame retardant halogen free flexible cables Selection and ordering data Number of Cores x Size Insulation colour Part No. Approx. No of Strands x Max. Strand of bare conductor Cable Overall Cable Weight Unenclosed Touch mm² mm mm Min mm Max mm kg/km A 1 x 0.75 black 5DR x x 1 black 5DR x x 1.5 black 5DR x x 2.5 black 5DR x x 4 black 5DR x x 6 black 5DR x x 10 black 5DR x x 16 black 5DR x x 25 black 5DR x x 35 black 5DR x x 50 black 5DR x x 70 black 5DR x x 95 black 5DR x

28 SINOTHERM High temperature 180 c silicone flexible cables APPLICATION Switchboard & cubical wiring Transformer and capacitor cabling High output floodlights Chemical & ceramic industry Injection moulding & extruders Steelworks / hot strip rolling mills Foundries & cooking plants Heating appliances Motor rewinders DESIGN SINOTHERM cables consist of fine stranded copper conductors laid up to provide a flexible design. Silicone insulation offers high resistance to increased ambient temperatures, however with a low mechanical resistance to cuts and tearing. OPERATING TEMPERATURE Minimum and maximum permissible -55 C ambient temperature +180 C Maximum permissible conductor temperature 180 C Maximum permissible short circuit temperature 350 C Minimum ambient temperature for optimum fully flexible operation RESISTANCE TO CHEMICALS Occasional slight exposure to oil and grease is permitted but the cables must not lie continually in oil or grease. They must be protected against fuels and solvents by suitable insulation. In accordance with AS 3178 the single core 0.6/1kV SINOTHERM carries the SECV Approval No.89516V. MINIMUM BENDING RADII The following minimum bending radii must be observed to ensure operating reliability. These are applicable for both sub-zero and elevated temperatures. Fixed installation 4 x cable When freely flexing 5 x cable CURRENT CARRYING CAPACITY Current ratings are based on continuous operation at an ambient temperature of 150 C per the following table when installed unenclosed and touching. CURRENT CARRYING CAPACITY Current ratings are based on continuous operation at an ambient temperature of 150 C per the following table when installed unenclosed and touching. -40 C Size Amps At other temperatures these values must be converted using the following table. Ambient temp. up to C Current capacity as a % of values above Current ratings are based on continuous operation at an ambient temperature of 40 C per the following table when installed unenclosed and touching. Size Amps At other temperatures these values must be converted using the following table. C Factor VOLTAGE RATING Rated voltage:: Single core Uo/U = 0.6/1kV Multi core & glass braided: Uo/U = 300/500V 26

29 SINOTHERM High temperature 180 c silicone flexible cables Single Core Insulated Sinotherm No. of cores x size Part No. Approx. No. of strands x Max. strand of bare conductor Cable overall Cable weight Min Max mm2 mm mm mm kg/km 1 x 1.5 5DR x x 2.5 5DR x x 4 5DR x x 6 5DR x x 10 5DR x x 16 5DR x x 25 5DR x x 35 5DR x x 50 5DR x x 70 5DR x x 95 5DR x Single Core Sinotherm with Glass Fibre Braid (500V) No. of cores x size Part No. Approx. No. of strands x Max. strand of bare conductor Cable overall Cable weight Min Max mm2 mm mm mm kg/km 1 x 1 5DR x x 1.5 5DR x x 2.5 5DR x x 4 5DR x x 6 5DR x x 10 5DR x x 16 5DR x x 25 5DR x x 35 5DR x x 50 5DR x

30 SINOTHERM High temperature 180 c silicone flexible cables Multicore Sinotherm Flexible Cables (500) No. of cores x size Part No. Approx. No. of strands x Max. strand of bare conductor Cable overall Cable weight Min Max mm² mm mm mm kg/km 3 x DR x x 1.5 5DR x x 1.5 5DR x x 2.5 5DR x x 1.5 5DR x CORE COLOUR IDENTIFICATION 2 core - blue, brown 3 core - blue, brown, green/yellow 4 core - blue, brown, black, green/yellow 5 core - blue, brown, black, green/yellow, black A single core 660V is available in a range of colours for control wiring in black, red, pink, green/yellow, blue, orange, brown, white and grey. Coloured Sinotherm s tinned to AS

31 SIEMENS SPECIALTY CABLES KabEx Australia is a authorised reseller of Siemens specialty cables. We can offer custom advice to suit any industrial application. CRANE, REELING & HOIST CABLES Planoflex Flat festoon crane cable. R-EP-90 elastomer insulation, HD-PCP- 90 sheath, 90DegC rated, flame retardant, oil resistant. Cordaflex (SMK) Cable reelers, festoon systems and force guided applications where high dynamic and static forces are induced into the cable. SPECIAL PURPOSE ELASTOMER CABLES Hydrofirm Designed and approved for use in drinking water. For fresh, salt and lightly polluted water (60 C). Round version suitable for depths up to 2000mt. Protomont HD Heavy duty flexible for aggressive environments. Designed for use in open cut mining and quarries, industry and construction sites as well as agriculture use where heavy mechanical stresses occur. MINING & HIGH VOLTAGE REELING CABLES Protomont XHD Extra heavy duty flexible mining cables. Combine flexibility with toughness to provide long service life in aggressive operating conditions. Protolon High voltage reeling & trailing cables. Designed to withstand the forces of reeling and force guidance systems on today s mobile equipment. A range of designs available to suit all applications including stackers, reclaimers, shiploaders, cranes, shovels, dredges, electric drills and draglines. 120DegC SOLAR CABLES: Cable - Connectors Leads Halogen Free, Flame Retardant, Resistant to Oils & Grease, Ozone and UV Resistant, 120Deg rated. Can be used indoor, outdoor and in explosion hazardous areas. Meets guidelines for green star points on building projects endorsed for government rebates. 29

32 GRP Junction Boxes OSGP Type APPLICATION The OSGP GRP junction boxes have proven their use in many sectors of industry. The OSGP GRP enclosure comprise 5 sizes of enclosure manufactured in Glass Fibre Reinforced Polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and also is suitable for LSOH (low smoke zero halogen) applications. Polyester gives excellent mechanical strength and life expectancy. The OSGP enclosures are suitable for use with in hazardous areas and can be supplied certificates, such as ATEX and IECEx TeChNICAL INfORmATION / specifications Material : Glass Fibre Reinforced Polyester (GRP) Area Classification : Zone 1, Zone 2, Zone 21 and Zone 22 Ingress Protection : IP66, IP67 -EN/IEC Wide Operating Temperature : -70 ~ +130 Certificate : ATEX Eex e, IECEx e Impact Resistance : 7Nm (EN50014) Color : RAL9005 Black Toxicity : Low Smoke Halogen-Free V-0 Self Extinguishing, UL94 Gasket : Silicon rubber Mounting : Integral 4.5mm clearance holes moulded into the body Earthing : Optional M6 internal/external earth stud, brass or stainless steel Surface Insulation Resistance : 106Ohm black 109Ohm, model TYPe Type (** Terminal block is WDu series or equivalent products.) (** T+B : Top+Bottom, L+R: Left+Right) Individual product data sheets available from 30 W(width)*h(height)*D(depth W H D Weight empty(g) Pack Qty OsgP g 100 OsgP g OsgP g 100 OsgP pcs 100 OsgP g OsgP1 OsgP2 OsgP3 OsgP4 OsgP5 WDu2.5 1*12 1*30 1*20 1*36 1*52 WDu4 1*11 1*28 1*18 1*33 1*48 WDu6 1*11 1*22 1*13 1*27 1*40 m20/ NPT1/2" m25/ NPT3/4" m32/ NPT1" OsgB1 OsgB2 OsgB3 OsgB4 OsgB5 T + B L+R T + B L+R T + B L+R T + B L+R T + B L+R CeRTIfICATION: IECEx. ATEX TYPe DesIgNATION: The COMPLETE MODEL No is as follows : OSGP1 4 M O T No. DesCRIPTION symbol DeTAIL BAsIC mode OsgP1 122*120*90 OsgP2 OsgP3 OsgP4 OsgP5 220*120*90 160*160*90 260*160*90 360*160*90 TB size(sq) sQ 04 4sQ 06 6sQ 10 10sQ 16 16sQ 35 35sQ entry m metric ThReAD TYPe NPT NPT entry size 0 m16 OR NPT 1/2" 1 m20 OR NPT 1/2" 2 m25 OR NPT 3/4" 3 m32 OR NPT 1" entry size T TOP side B L R BOTTOm side LefT side ReghT side Q'TY Of 01 1eA entry(ea) 02 2eA 03 3eA eA

33 Non Armoured Cable Gland Exd IIC/Exe II/ExtD A21 OSNJ-A2F Type Flameproof & Increased Safety APPLICATION For use with Non armoured cable in hazardous area. Single compression for outer jacket of cable. Protection: Exd IIC/Exe II/ExtD A21, IP67 Suitable for use in Zone1, 2, 21 and 22. Certification: IECEx, Atex Nemko, GOST R Material: Brass with Nickle plated For Stainless Steel add /SS to part number Part No. Entry Thread Size Cable Outer Thread Length Entry Hole Size Hexagon Dimensions 'H' Shroud Size OSNJA2F-16AM16 M H24 X 26 OSSH-16(B) OSNJA2F-16BM16 M H24 X 26 OSSH-16(B) OSNJA2F-16AM20 M H24 X 26 OSSH-16(B) OSNJA2F-16BM20 M H24 X 26 OSSH-16(B) OSNJA2F-20AM20 M H27 X 29 OSSH-20(B) OSNJA2F-20BM20 M H27 X 29 OSSH-20(B) OSNJA2F-25A M H32 X 34 OSSH-25(B) OSNJA2F-25B M H32 X 34 OSSH-25(B) OSNJA2F-32A M H39 X 41.5 OSSH-32(B) OSNJA2F-32B M H39 X 41.5 OSSH-32(B) OSNJA2F-40A M H48 X 51 OSSH-40(B) OSNJA2F-40B M H48 X 51 OSSH-40(B) OSNJA2F-50A M H58 X 62 OSSH-50(B) OSNJA2F-50B M H58 X 62 OSSH-50(B) OSNJA2F-63A M H73 X 78 OSSH-63(B) OSNJA2F-63B M H73 X 78 OSSH-63(B) OSNJA2F-63C M H73 X 78 OSSH-63(B) OSNJA2F-75A M H85 X 90 OSSH-75(B) OSNJA2F-75B M H85 X 90 OSSH-75(B) OSNJA2F-75C M H85 X 90 OSSH-75(B) OSNJA2F-75D M H85 X 90 OSSH-75(B) OSNJA2F-90A M H103 X 113 OSSH-90(B) OSNJA2F-90B M H103 X 113 OSSH-90(B) OSNJA2F-100A M H112 X 120 OSSH-100(B) OSNJA2F-100B M H112 X 120 OSSH-100(B) NPT threads available upon request 31

34 Stopping Plug Exd IIC/Exe II/ExtD A21 OSSP-R & OSSP-H Type Flameproof & Increased Safety APPLICATION: To close unused cable gland entries and maintain the flameproof and increased safety integrity of the equipment Protection: Exd IIC/Exe II/ExtD A21, IP66/67 Suitable for use in Zone1, 2, 21 and 22. Certification: IECEx, Atex Nemko, GOST R Material: Brass with Nickle Plated For Stainless Steel add /SS to part number Stopping Plug Metric Part Number Thread Size Thread Length Stopping Plug PG Part Number Thread Size Thread Length OSSP-R101/M16 M OSSP-R102/M20 M OSSP-R103/M25 M OSSP-R104/M32 M OSSP-R105/M40 M OSSP-R106/M50 M OSSP-R107/M63 M OSSP-R108/M75 M OSSP-R109/M90 M OSSP-R110/M100 M OSSP-R101/PG7 PG OSSP-R101/PG9 PG OSSP-R101/PG11 PG OSSP-R102/PG13.5 PG OSSP-R103/PG16 PG OSSP-R104/PG21 PG OSSP-R105/PG29 PG OSSP-R106/PG36 PG OSSP-R107/PG42 PG OSSP-R108/PG48 PG Stopping Plug NPT Part Number Thread Size Thread Length OSSP-R102/NPT1/2 1/2"NPT OSSP-R103/NPT3/4 3/4"NPT OSSP-R104/NPT1 1"NPT OSSP-R105/NPT11/4 1 1/4"NPT OSSP-R106/NPT11/2 1 1/2"NPT OSSP-R107/NPT2 2"NPT OSSP-R108/NPT21/2 2 1/2"NPT OSSP-R109/NPT3 3"NPT OSSP-R109/NPT31/2 3 1/2"NPT Hexagonal Head replace R with H to part number 32

35 Reducer Exd IIC/Exe II/ExtD A21 OSRA Type Flameproof & Increased Safety APPLICATION: Provides a means of connection between cable entry devices and equipment having dissimilar threads. Protection: Exd IIC/Exe II/ExtD A21, IP66/67 Suitable for use in Zone1, 2, 21 and 22 Certification: IECEx, Atex Nemko, GOST R Material: Brass with Nickle Plated For Stainless Steel add /SS to part number Reducer Entry Thread Size Dimensions Part Number Male Female OSRA-101/M1 M20 M16 H25 X 27 OSRA-102/M1 M25 M16 H30 X 33 OSRA-102/M2 M25 M20 H30 X 33 OSRA-103/M1 M32 M16 H38 X 41 OSRA-103/M2 M32 M20 H38 X 41 OSRA-103/M3 M32 M25 H38 X 41 OSRA-104/M1 M40 M20 H45 X 48 OSRA-104/M2 M40 M25 H45 X 48 OSRA-104/M3 M40 M32 H45 X 48 OSRA-105/M1 M50 M25 H55 X 59 OSRA-105/M2 M50 M32 H55 X 59 OSRA-105/M3 M50 M40 H55 X 59 OSRA-106/M1 M63 M32 H68 X 72 OSRA-106/M2 M63 M40 H68 X 72 OSRA-106/M3 M63 M50 H68 X 72 OSRA-107/M1 M75 M40 H82 X 88 OSRA-107/M2 M75 M50 H82 X 88 OSRA-107/M3 M75 M63 H82 X 88 OSRA-101/PM21 PG11 M16 H21 X 23 OSRA-101/PM11 PG13.5 M20 H25 X 27 OSRA-102/PM1 PG16 M16 H25 X 29 OSRA-102/PM2 PG16 M20 H25 X 29 OSRA-103/PM1 PG21 M20 H34 X 37 OSRA-103/PM2 PG21 M25 H34 X 37 OSRA-104/PM1 PG29 M20 H43 X 46 OSRA-104/PM2 PG29 M25 H43 X 46 OSRA-104/PM3 PG29 M32 H43 X 46 Other sizes available upon request Reducer Entry Thread Size Dimensions Part Number Male Female OSRA-102/NM0 1/2"NPT M16 H30 X 33 OSRA-103/NM1 3/4"NPT M20 H38 X 41 OSRA-104/NM1 1"NPT M20 H45 X 48 OSRA-104/NM2 1"NPT M25 H45 X 48 OSRA-105/NM1 1 1/4"NPT M20 H55 X 59 OSRA-105/NM2 1 1/4"NPT M25 H55 X 59 OSRA-105/NM3 1 1/4"NPT M32 H55 X 59 OSRA-106/NM1 1 1/2"NPT M20 H68 X 72 OSRA-106/NM2 1 1/2"NPT M25 H68 X 72 OSRA-106/NM3 1 1/2"NPT M32 H68 X 72 OSRA-106/NM4 1 1/2"NPT M40 H68 X 72 OSRA-107/NM2 2"NPT M25 H82 X 88 OSRA-107/NM3 2"NPT M32 H82 X 88 OSRA-107/NM4 2"NPT M40 H82 X 88 OSRA-107/NM5 2"NPT M50 H82 X 88 OSRA-103/N1 3/4"NPT 1/2"NPT H38 X 41 OSRA-104/N1 1"NPT 1/2"NPT H45 X 48 OSRA-104/N2 1"NPT 3/4"NPT H45 X 48 OSRA-105/N1 1 1/4"NPT 1/2"NPT H55 X 59 OSRA-105/N2 1 1/4"NPT 3/4"NPT H55 X 59 OSRA-105/N3 1 1/4"NPT 1"NPT H55 X 59 OSRA-106/N1 1 1/2"NPT 3/4"NPT H68 X 72 OSRA-106/N2 1 1/2"NPT 1"NPT H68 X 72 OSRA-106/N3 1 1/2"NPT 1 1/4"NPT H68 X 72 OSRA-107/N1 2"NPT 1"NPT H82 X 88 OSRA-107/N2 2"NPT 1 1/4"NPT H82 X 88 OSRA-107/N3 2"NPT 1 1/2"NPT H82 X 88 33

36 Adaptor Exd IIC/Exe/ExtD A21 OSAJ Type Flameproof & Increased Safety APPLICATION: Provides a means of connection between cable entry devices and equipment having dissimilar threads. Protection: Exd IIC/Exe II/ExtD A21, IP66/67 Suitable for use in Zone1, 2, 21 and 22. Certification: IECEx, Atex Nemko, GOST R Material: Brass with Nickle Plated For Stainless Steel add /SS to part number Reducer Entry Thread Size Dimensions Part Number Male Female OSAJ-101/M1 M16 M20 H25 X 27 OSAJ-102/M1 M16 M25 H30 X 33 OSAJ-102/M2 M20 M25 H30 X 33 OSAJ-103/M1 M16 M32 H37 X 40 OSAJ-103/M2 M20 M32 H37 X 40 OSAJ-103/M3 M25 M32 H37 X 40 OSAJ-104/M1 M20 M40 H46 X 50 OSAJ-104/M2 M25 M40 H46 X 50 OSAJ-104/M3 M32 M40 H46 X 50 OSAJ-105/M1 M25 M50 H57 X 61 OSAJ-105/M2 M32 M50 H57 X 61 OSAJ-105/M3 M40 M50 H57 X 61 OSAJ-106/M1 M32 M63 H70 X 75 OSAJ-106/M2 M40 M63 H70 X 75 OSAJ-106/M3 M50 M63 H70 X 75 OSAJ-107/M1 M40 M75 H82 X 89 OSAJ-107/M2 M50 M75 H82 X 89 OSAJ-107/M3 M63 M75 H82 X 89 OSAJ-101/PM1 PG7 M20 H21 X 23 OSAJ-101/PM2 PG9 M20 H21 X 23 OSAJ-102/PM1 PG9 M25 H27 X 30 OSAJ-102/PM2 PG11 M25 H27 X 30 OSAJ-102/PM3 PG13.5 M25 H27 X 30 OSAJ-103/PM1 PG9 M32 H34 X 37 OSAJ-103/PM2 PG11 M32 H34 X 37 OSAJ-103/PM3 PG13.5 M32 H34 X 37 OSAJ-103/PM4 PG16 M32 H34 X 37 Other sizes available upon request 34 Reducer Entry Thread Size Dimensions Part Number Male Female OSAJ-101/NM1 1/2"NPT M20 H25 X 27 OSAJ-102/MN1 M20 1/2"NPT H25 X 27 OSAJ-101/NM1 1/2"NPT M20 H25 X 27 OSAJ-103/NM2 3/4"NPT M25 H30 X 33 OSAJ-103/NM3 3/4"NPT M32 H38 X 41 OSAJ-104/NM3 1"NPT M32 H38 X 41 OSAJ-105/NM4 1 1/4"NPT M40 H48 X 52 OSAJ-106/NM5 1 1/2"NPT M50 H55 X 59 OSAJ-107/NM6 2"NPT M63 H68 X 73 OSAJ-102/N1 1/2"NPT 3/4"NPT H30 X 33 OSAJ-103/N1 1/2"NPT 1"NPT H38 X 41 OSAJ-103/N2 3/4"NPT 1"NPT H38 X 41 OSAJ-104/N1 3/4"NPT 1 1/4"NPT H48 X 52 OSAJ-104/N2 1"NPT 1 1/4"NPT H48 X 52 OSAJ-105/N1 1"NPT 1 1/2"NPT H55 X 59 OSAJ-105/N2 1 1/4"NPT 1 1/2"NPT H55 X 59 OSAJ-106/N1 1 1/4"NPT 2"NPT H68 X 73 OSAJ-106/N2 1 1/2"NPT 2"NPT H68 X 73 OSAJ-107/N1 1 1/2"NPT 2 1/2"NPT H82 X 88 OSAJ-107/N2 2"NPT 2 1/2"NPT H82 X 88

37 Elbow Exd IIC/Exe II/ExtD A21 OSAE Types APPLICATION For application in installation areas with small amounts of space. Lock nut in any position. Protection: Exd IIC/Exe II/ExtD A21, IP67 Suitable for use in Zone1, 2, 21 and 22. Certification: IECEx Material: Brass with Nickle plated For Stainless Steel add /SS to part number Round Type/ Entry Thread Size (M) L1 D d S Siz e Metric NPT OSAE-M OSAE-F OSAE-MF L2 L OSAE-16 M16 1/2" OSAE-20 M20 1/2" OSAE-25 M25 3/4" OSAE-32 M32 1" OSAE-40 M40 1 1/4" OSAE-50 M50 1 1/2" OSAE-63 M63 2" OSAE-75 M75 2 1/2" Ordering Code Examples OSAE-M20(F)XM20(F) M20 Female to M20 Female OSAE-M20(M)XM20(F) M20 Male to M20 Female OSAE-M20(M)XM20(M) M20 Male to M20 Male OSAE-M20(M)XNPT1/2(F) M20 Male to NPT 1/2" Female OSAE-NPT1/2(M)XM20(F) NPT 1/2" Male to M20 Female OSAE-NPT1/2(M)XNPT1/2(M) NPT 1/2" Male to NPT 1/2" Male Phone for all other ordering code combinations as listed in above table 35

38 Metal Non Armoured Cable Gland OSNJ Type APPLICATION Outdoor & Indoor. Industrial cable gland for use with non armoured cables. Protection: IP67 Regulation: According to BS, IEC Material: Brass with Nickle Plated For Stainless Steel add /SS to part number 36 Part No. Entry Thread Size Cable Outer Thread Length Entry Hole Size Hexagon Dimensions 'H' Shroud Size OSNJ-16AM16 M H24 X 26 OSSH-16(B) OSNJ-16BM16 M H24 X 26 OSSH-16(B) OSNJ-16AM20 M H24 X 26 OSSH-16(B) OSNJ-16BM20 M H24 X 26 OSSH-16(B) OSNJ-20AM20 M H27 X 29 OSSH-20(B) OSNJ-20BM20 M H27 X 29 OSSH-20(B) OSNJ-25A M H32 X 34 OSSH-25(B) OSNJ-25B M H32 X 34 OSSH-25(B) OSNJ-32A M H39 X 41.5 OSSH-32(B) OSNJ-32B M H39 X 41.5 OSSH-32(B) OSNJ-40A M H48 X 51 OSSH-40(B) OSNJ-40B M H48 X 51 OSSH-40(B) OSNJ-50A M H58 X 62 OSSH-50(B) OSNJ-50B M H58 X 62 OSSH-50(B) OSNJ-63A M H73 X 78 OSSH-63(B) OSNJ-63B M H73 X 78 OSSH-63(B) OSNJ-63C M H73 X 78 OSSH-63(B) OSNJ-75A M H85 X 90 OSSH-75(B) OSNJ-75B M H85 X 90 OSSH-75(B) OSNJ-75C M H85 X 90 OSSH-75(B) OSNJ-75D M H85 X 90 OSSH-75(B) OSNJ-90A M H103 X 113 OSSH-90(B) OSNJ-90B M H103 X 113 OSSH-90(B) OSNJ-100A M H112 X 120 OSSH-100(B) OSNJ-100B M H112 X 120 OSSH-100(B) NPT threads available upon request

39 Armoured Cable Gland OSNJ-CW Type APPLICATION Outdoor & Indoor. For use with steel wire armoured cable. Single compression for outer jacket of cable. Regulation: According to BS, IEC Protection: IP66 Material: Brass with Nickle plated For Stainless Steel add /SS to part number Part No. Entry Thread Size Cable Outer Thread Length Entry Hole Size Armour Range Hexagon Dimensions 'H' OSNJ-CW-16AM16 M /1.25 H25 X 27 OSNJ-CW-16BM16 M /1.25 H25 X 27 OSNJ-CW-16AM20 M /1.25 H25 X 27 OSNJ-CW-16BM20 M /1.25 H25 X 27 OSNJ-CW-20AM20 M /1.25 H31 X 33 OSNJ-CW-20BM20 M /1.25 H31 X 33 OSNJ-CW-25A M /1.6 H36 X 39 OSNJ-CW-25B M /1.6 H36 X 39 OSNJ-CW-32A M /2.0 H45 X 49 OSNJ-CW-32B M /2.0 H45 X 49 OSNJ-CW-40A M /2.0 H55 X 59 OSNJ-CW-40B M /2.0 H55 X 59 OSNJ-CW-50A M /2.5 H68 X 73 OSNJ-CW-50B M /2.5 H68 X 73 OSNJ-CW-63A M /2.5 H82 X 88 OSNJ-CW-63B M /2.5 H82 X 88 OSNJ-CW-63C M /2.5 H82 X 88 OSNJ-CW-75A M /2.5 H98 X106 OSNJ-CW-75B M /2.5 H98 X106 OSNJ-CW-75C M /2.5 H98 X106 OSNJ-CW-75D M /2.5 H98 X106 OSNJ-CW-90A M /3.0 H110 X 120 OSNJ-CW-90B M /3.0 H110 X 120 OSNJ-CW-100A M /3.0 H120 X 130 OSNJ-CW-100B M /3.0 H120 X 130 NPT threads available upon request 37

40 Metal PG Thread Cable Gland OSPG Type DIN Standard APPLICATION Cable Glands according to DIN Standard Material: Brass with Nickle Plated Part No. Entry Thread Cable Outer Thread Length Hexagon Length 'L' Size Metric PG Dimensions 'H' OSPG-9 PG H19 X OSPG-11 PG H23 X OSPG-13.5 PG H24 X OSPG-16 PG H26 X OSPG-21 PG H31 X OSPG-29 PG H42 X OSPG-36 PG H52 X OSPG-42 PG H60 X OSPG-48 PG H66 X Shrouds OSSH Type DIN Standard APPLICATION For fitting over cable glands Glands in inside or outside applications Material: EPDM CR70 Material: For Armoured Cable Glands OSSH-16(A) OSSH-20(A) OSSH-25(A) OSSH-32(A) OSSH-40(A) OSSH-50(A) OSSH-63(A) OSSH-75(A) 38 for Non-Armoured Cable OSSH-16(A) OSSH-20(A) OSSH-25(A) OSSH-32(A) OSSH-40(A) OSSH-50(A) OSSH-63(A) OSSH-75(A)

41 Earth Tag Metric Part No. OSET-101/M16 OSET-102/M20 OSET-103/M25 OSET-104/M32 OSET-105/M40 OSET-106/M50 OSET-107/M63 OSET-108/M75 OSET-109/M90 Description M16 Earth Tag M20 Earth Tag M25 Earth Tag M32 Earth Tag M40 Earth Tag M50 Earth Tag M63 Earth Tag M75 Earth Tag M90 Earth Tag For Stainless Steel add /SS to part number Metal Lock Nut Metric Part No. OSLN-M16 OSLN-M20 OSLN-M25 OSLN-M32 OSLN-M40 OSLN-M50 OSLN-M63 OSLN-M75 OSLN-M90 Description M16 Metal Lock Nut M20 Metal Lock Nut M25 Metal Lock Nut M32 Metal Lock Nut M40 Metal Lock Nut M50 Metal Lock Nut M63 Metal Lock Nut M75 Metal Lock Nut M90 Metal Lock Nut For Stainless Steel add /SS to part number Serrated Teeth Washer Description OSTW-M16 M16 Stainless Steel Serrated Washer OSTW-M20 M20 Stainless Steel Serrated Washer OSTW-M25 M25 Stainless Steel Serrated Washer OSTW-M32 M32 Stainless Steel Serrated Washer OSTW-M40 M40 Stainless Steel Serrated Washer OSTW-M50 M50 Stainless Steel Serrated Washer OSTW-M63 M63 Stainless Steel Serrated Washer OSTW-M75 M75 Stainless Steel Serrated Washer OSTW-M90 M90 Stainless Steel Serrated Washer Teflon Sealing Washer Description OSSR-M16 OSSR-M20 OSSR-M25 OSSR-M32 OSSR-M40 OSSR-M50 OSSR-M63 OSSR-M75 OSSR-M90 M16 Sealing Washer M20 Sealing Washer M25 Sealing Washer M32 Sealing Washer M40 Sealing Washer M50 Sealing Washer M63 Sealing Washer M75 Sealing Washer M90 Sealing Washer 39

42 Cable Termination Accessories Stainless Steel Cable Ties KABEX Stainless Steel Cable Ties are Grade 316 Stainless and available in coated or uncoated versions, Standard widths of 4.6 mm or 7.9 mm and available in various lengths. This tie is of a roller-ball design which is self locking and fast & easy to install. It can be tightened by hand or with a special tool. The normal operating range for the roller ball uncoated ties version is -80C to +538C approximately. For coated version normal operating range is -80C to +150C. Fully coated roller ball tie (Patent Pending) is recommended for extreme cold conditions and offshore applications. Coating is non toxic halogen free Polyester. It is available in wide choice of colours. Stainless Steel Cable Ties Type: Roller Ball Grade : SS316 Part Number Description Length mm Width mm Max Bundle Dia ST x 4.6mm Stainless Steel Uncoated ST x 4.6mm Stainless Steel Uncoated ST x 4.6mm Stainless Steel Uncoated ST x 4.6mm Stainless Steel Uncoated ST x 4.6mm Stainless Steel Uncoated ST200H 200 x 7.9mm Stainless Steel Uncoated ST360H 360 x 7.9mm Stainless Steel Uncoated ST520H 520 x 7.9mm Stainless Steel Uncoated ST680H 680 x 7.9mm Stainless Steel Uncoated ST1000H 1000 x 7.9mm Stainless Steel Uncoated ST200C 200 x 4.6mm Stainless Steel Coated ST360C 360 x 4.6mm Stainless Steel Coated ST200HC 200 x 7.9mm Stainless Steel Coated ST360HC 360 x 7.9mm Stainless Steel Coated Other sizes available for Coated Versions upon request mm Minimum Loop Tensile Strength: 4.6 mm width Un-coated (44.5 kg) 100 lbs 7.9 mm width Un-coated (111.2 kg) 250 lbs 4.6 mm width Coated (44.5 kg) 100 lbs 7.9 mm width Coated (55 kg) 120 lbs 40

43 Cable Termination Accessories Nylon Cable Ties Material Specification: Made from U.L. approved nylon 6/6. Operating Temperature -40 to 85DegC Flambility rating: UL 94V-2. Black Weather Resistant Nylon with Carbonate "A" added for greater resistance to ultra violet in outdoor application. Specification: Made to comply with mil-spec drawing no. MS-3367 tensile strength meet or exceed MIL-S-23190E standard. Approvals: UL approved DVN approved VDE approved GL approved Lloyds Register approved ROHS Compliant Cable Ties - Natural Part Number Description Max. Bundle Min. Loop Tensile Strength Dia Lbs Kg Newtons CT100NT-100 CABLE TIE 100MM X 2.5MM NATURAL CT150NT-100 CABLE TIE 150MM X 3.6MM NATURAL CT200NT-100 CABLE TIE 203MM X 4.8MM NATURAL CT250NT-100 CABLE TIE 100MM X 2.5MM NATURAL CT300NT-100 CABLE TIE 300MM X 4.8MM NATURAL CT370NT-100 CABLE TIE 368MM X 4.8MM NATURAL CT380NTHD CABLE TIE 380MM X 7.6MM NATURAL Cable Ties - Black UV Resistant Part Number Description Max. Bundle Min. Loop Tensile Strength Dia Lbs Kg Newtons CT100NT-100 CABLE TIE 100MM X 2.5MM BLACK CT150NT-100 CABLE TIE 150MM X 3.6MM BLACK CT200NT-100 CABLE TIE 203MM X 4.8MM BLACK CT250NT-100 CABLE TIE 100MM X 2.5MM BLACK CT300NT-100 CABLE TIE 300MM X 4.8MM BLACK CT370NT-100 CABLE TIE 100MM X 2.5MM BLACK CT380NTHD CABLE TIE 380MM X 7.6MM BLACK Cable Ties - Light Duty Part Number Description Max. Bundle Min. Loop Tensile Strength Dia Lbs Kg Newtons CT200LDNT CABLE TIE 203MM X 2.5MM NATURAL CT200MDNT CABLE TIE 203MM X 3.6MM NATURAL CT200LDBK CABLE TIE 203MM X 2.5MM BLACK CT200MDBK CABLE TIE 203MM X 3.6MM BLACK

44 Cable Termination Accessories IP68 NYLON CABLE GLAND UL Approved Nylon 66, 94V-2 IP68 Rating Halogen Free ROHS Compliant Part Number Thread Cable OD: Std Pack MG12 M MG16 M MG20 M MG25 M MG32 M MG40 M MG50 M MG63 M OPEN SLOTTED DUCT High impact, self extinguishing, warp proof 94V-0 PVC Max. Service Temperature: 85 C Standard colour: Grey Blue Intrinsically Safe version add BLUE to Part Number. Part No. W X H length SD X 25 SD X 25 SD X 45 SD X 45 SD X 45 SD X 65 SD X 100 SD X 75 SD X 100 SD X 100 2m 42

45 Cable Termination Accessories Bootlace Ferrules L L1 D Part Number Wire Size (mm²) Dimensions Colour Pack Size L W T BLP025/ Violet 100 BLP034/ Pink 100 BLP050/ White 100 BLP075/ Blue 100 BLP100/ Red 100 BLP150/ Black 100 BLP250/ Grey 100 BLP400/ Orange 100 BLP600/ Green 50 BLP1000/ Brown 25 BLP1600/ Ivory 25 BLP2500/ Black 10 BLP3500/ Red 10 BLP5000/ Blue 10 BLP7000/ Yellow 5 BLP9500/ Red 3 BLP12000/ Blue 3 BLP15000/ Yellow 3 Twin Bootlace Ferrules Part Number Wire Size (mm²) Dimensions Colour Pack Size L W T BLPT050/100 2 x White 100 BLPT075/100 2 x Grey 100 BLPT100/100 2 x Red 100 BLPT150/100 2 x Black 100 BLPT250/100 2 x Blue 100 BLPT400/50 2 x Grey 50 BLPT600/25 2 x Yellow 25 BLPT1000/10 2 x Red 10 BLPT1600/10 2 x Blue 10 43

46 Cable Termination Accessories Copper Lugs D E F B A C G Part No. Standard 44 Part No. Bellmouth Nom Cond. Stud Size DIMENSION AUSTRALIAN TYPE A B C D E F G KL1.5-4 KL1.5-4BM KL1.5-5 KL1.5-5BM KL1.5-6 KL1.5-6BM KL2.5-4 KL2.5-4BM KL2.5-5 KL2.5-5BM KL2.5-6 KL2.5-6BM KL2.5-8 KL2.5-8BM KL4-5 KL4-5BM KL4-6 KL4-6BM KL4-8 KL4-8BM KL4-10 KL4-10BM KL6-5 KL6-5BM KL6-6 KL6-6BM KL6-8 KL6-8BM KL6-10 KL6-10BM KL10-5 KL10-5BM KL10-6 KL10-6BM KL10-8 KL10-8BM KL10-10 KL10-10BM KL10-12 KL10-12BM KL16-6 KL16-6BM KL16-8 KL16-8BM KL16-10 KL16-10BM KL16-12 KL16-12BM KL25-6 KL25-6BM KL25-8 KL25-8BM KL25-10 KL25-10BM KL25-12 KL25-12BM KL35-6 KL35-6BM KL35-8 KL35-8BM KL35-10 KL35-10BM KL35-12 KL35-12BM KL50-6 KL50-6BM KL50-8 KL50-8BM KL50-10 KL50-10BM KL50-12 KL50-12BM KL70-6 KL70-6BM KL70-8 KL70-8BM KL70-10 KL70-10BM KL70-12 KL70-12BM KL70-16 KL70-16BM KL95-8 KL95-8BM KL95-10 KL95-10BM KL95-12 KL95-12BM

47 Cable Termination Accessories Copper Lugs Part No. Standard Part No. Bellmouth Nom Cond. Stud Size DIMENSION AUSTRALIAN TYPE A B C D E F G KL95-16 KL95-16BM KL120-8 KL120-8BM KL KL120-10BM KL KL120-12BM KL KL120-16BM KL KL150-10BM KL KL150-12BM KL KL150-16BM KL KL185-10BM KL KL185-12BM KL KL185-16BM KL240 KL240BM KL KL240-10BM KL KL240-12BM KL KL240-16BM KL300 KL300BM KL KL300-12BM KL KL300-16BM KL400 KL400BM KL500 KL500BM KL630 KL630BM Copper Crimp Links Part No. Nom Cond. Overall Length I.D. KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC KC

48 Cable Termination Accessories KM65 Cable Markers KABEX KM65 Cable Markers are a versatile cable marking system for labelling small and large cables, conduits and pipes. Cable Markers with their unique oval shape can slip directly over small cables before termination or slip onto Carrier Strips to suit larger cable or cable bundles. Cable Markers Made of the finest soft grade, strong, durable PVC. KABEX KM65 Cable Markers are resistant to oil, grease and other material erosion. Part Number Marking Suitable Range Width Pack Qty KM65-A A KM65-B B KM65-C C KM65-D D KM65-E E KM65-F F KM65-G G KM65-H H KM65-I I KM65-J J KM65-K K KM65-L L KM65-M M KM65-N N KM65-O O KM65-P P KM65-Q Q KM65-R R KM65-S S KM65-T T KM65-U U KM65-V V Part Number Marking Suitable Range Width Pack Qty KM65-W W KM65-X X KM65-Y Y KM65-Z Z KM KM KM KM KM KM KM KM KM KM KM65-11 / KM KM KM KM65-16 EARTH KM65-17 BLANK Carrier Strips UL Approved Nylon 66 (Black) with flammability rating 94V-2. Cable tie fastening holes to accomodate marker pieces for easy identification of cable runs. W Part Number Dimensions Capacity (max. KM65 L W T Markers) 46 L T Pack Qty KM pcs 100 KM pcs 100 KM pcs 100 KM65-135L pcs 100

INSTRUMENTATION CABLE

INSTRUMENTATION CABLE APPLICATION Used in data processing and process control. Suitable for fixed installations in damp locations and open spaces. The electrostatic screen protects against outer interference fields. Design

More information

Ph: Product Catalogue Industrial Cables Hazardous area equipment Cable termination

Ph: Product Catalogue Industrial Cables Hazardous area equipment Cable termination 2013 Product Catalogue Industrial Cables Hazardous area equipment Cable termination KabEx Australia is a leading company specializing in the supply of cables, hazardous area equipment and cable termination

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application ENERGY TECWATER EMV-FC S1BC4N8-F 0,6/1 kv Screened Cable for Water Application Technical Data Trademark Type designation Specification Application TECWATER EMV-FC S1BC4N8-F Design and tests according to

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON (ST) NTSCGECEWÖU.../3E Approvals/

More information

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS ENERGY HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv Screened Cable for Drinking Water Application KTW/ACS Technical Data Trademark Type designation Specification Application HYDROFIRM(T) EMV-FC S1BC4B-F Design

More information

Industry Cables Special cables for industrial applications General Catalogue

Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General Catalogue Industry Cables Special cables for industrial applications General catalogue Linking the Future As the worldwide leader in the

More information

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813

More information

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)

More information

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation 2 17 BUIS_003.tif 2 18 BUIS_004.tif Selection and dimensioning criteria Refer to Section 4 for further details

More information

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics ENERGY TECSUN(PV) PV1-F Cables for Photovoltaics Technical Data Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / Germany TECSUN (PV) PV1-F Approvals

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM)

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM) CORDAFLEX (SM) Portable reel cable EP insulation, dual neoprene jacket with braid reinforcement, 90 C, 600 volts Rack and pinion elevators using sheave guided cables Container crane spreader reels Timber

More information

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics ENERGY TECSUN(PV) PV1 F Cables for Photovoltaics Technical Data Electrical Thermal Manufacturer Trademark Type designation Prysmian Kabel und Systeme GmbH Kabelwerk Neustadt bei Coburg / DE TECSUN (PV)

More information

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable ()SSHÖU O/J, ()SSHÖU 3E, ()SSHÖU 3E + ST 0.6/1kV Cable Eland Product Group: A7JS APPLICATIO Heavy duty tough rubber flexible cable with or without individually earth screened cores for dynamic or static

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

DURAREEL TRAILING REELING CABLE

DURAREEL TRAILING REELING CABLE Supplementary Technical Information Reeling and trailing material characteristics: A. Power core conductor Flexible strands tinned annealed copper complies with AS/NZS 1802, AS/NZS 2802, AS/NZS 1125, and

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY Technical Data Electrical Thermal Trademark Type designation Specification Application

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

ENERGY. Solar Cables

ENERGY. Solar Cables ENERGY Solar Cables Contents TECSUN(PV) PV1-F Cables for Photovoltaics 3 Technical Data 4 Design Features 6 Selection and Ordering Data 6 TECSUN DUO (PV) Cables for Photovoltaics 7 Technical Data 8 Design

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 110 CY Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES * october 2004 TRATOSFLEX 2 Selection of type of cable in relation to use Recommended Bending Radius INDEX Current carrying capacities for continuos operation Current carrying capacities for intermittent

More information

Telephone Cables Fire Warning Cables

Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free

More information

Data sheet chainflex CF6

Data sheet chainflex CF6 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities Screened data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN 47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant Screened, Instrumentation

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology PUR feedback cables C-track compatible Subject to technical modification 111456 Identification Type SU+(C)P SE(4 0,5+4 2 0,38)UL 30V GN SIEMENS designation* 1BD21 Use/Application/Characteristics Application

More information

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5 Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail

More information

Data sheet chainflex CF10

Data sheet chainflex CF10 1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Extremely bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling TPE mixture

More information

Data sheet chainflex CF240

Data sheet chainflex CF240 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Data sheet chainflex CF140.UL

Data sheet chainflex CF140.UL 1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture 4. CFRIP: Tear strip

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

TRATOS OIL&GAS NEK606

TRATOS OIL&GAS NEK606 C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

DKSH provides expertise and solutions to industry

DKSH provides expertise and solutions to industry Business Unit Technology DKSH provides expertise and solutions to industry Industrial Services Australia Our Profile Locations VICTORIA (Head Office) 14-17 Dansu Court Hallam VIC 3803 Tel: +61 3 9554 6666

More information

CF270.UL.D.

CF270.UL.D. Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:

More information

Global data. Electrical parameters

Global data. Electrical parameters ()TSCGEWOEU TEAX TTS 3,6/6 kv: Application Flexible medium voltage reeling cable for application under high mechanical stresses, e.g. high travel speeds, dynamic loads, multiple changes of direction into

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

The BIG names in Cable for the BIG jobs in Cable. Flexible Cables

The BIG names in Cable for the BIG jobs in Cable. Flexible Cables The BIG names in Cable for the BIG jobs in Cable Control Treotham Automation is the exclusive distributor for one of the biggest names in the cable industry. Treotham now offers it s own exclusive brand

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES HIGH TEMPERATURE CABLES C O N T E N T S DEF 61-12 Part 18 Type 1 LFH Equipment Wires :2 Technical Information for DEF 61-12 :8 PTFE Insulated Equipment Wire Single Core :10 PTFE EFGLAS Aircraft Cable :12

More information

MOTOR, SERVO, & FEEDBACK CABLES

MOTOR, SERVO, & FEEDBACK CABLES MOTOR, SERVO, & FEEDBACK CABLES Motor, servo, and feedback cables Temperature ( C) - flexing Temperature ( C) - fixed Nominal voltage U 0 /U Bending radius - flexing x Ø Bending radius - fixed x Ø Halogen-free

More information

Data sheet chainflex CF8821

Data sheet chainflex CF8821 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE

More information

Data sheet chainflex CF5

Data sheet chainflex CF5 1. Outer jacket: Pressure extruded, gusset-filling, oilresistant PVC mixture 2. Core insulation: Mechanically high-quality TPE or PVC mixture 3. CFRIP: Tear strip for faster cable stripping 4. Conductor:

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,

More information

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with Application Flexible medium voltage reeling cable for high mechanical stresses (e.g. dynamic tensile loads, multiple changes

More information

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description. H05BQ-F, H07BQ-F The harmonized PUR cable with Europe wide registration according to HD 22.10 S1 VDE 0282 Description Application In dry, damp or wet areas for medium duty; e. g. for connection of industrial

More information

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276- Three Core Cables to VDE 0276 APPLICATIONS The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

Technical attributes

Technical attributes Technical attributes Standards adapted to DIN VDE 0281 Conductor material Cu, bare Conductor type flexible Conductor standard IEC 60228 Conductor category 5 Core insulation Core s black, number-coded,

More information

Technical Data Sheet Unshielded (YY) PVC Control Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Chemical resistance Accidental

Chemical resistance Accidental Industrial flexible cable, insulation and outer sheath in elastomer. Oil resistant, flame retardant according to IEC/EN 60332-1-2 standard. Description Application flexible cable is intended for installations

More information

Data sheet chainflex CFSOFT1

Data sheet chainflex CFSOFT1 to 5 x d Highly flexible, soft design PVC outer jacket Oil-resistant Flame retardant 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Core insulation: Mechanically high-quality TPE mixture

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc.

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. INTRODUCTION : Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. Rubber is still considered the preferred insulation for

More information

DNV-GL HH CE RoHS-II conform

DNV-GL HH CE RoHS-II conform Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable

More information

Electronic Instrumentation

Electronic Instrumentation Applications Electronic instrumentation, analog and digital signal circuits (4-20mA). Intrinsically safe circuits. Gas and/or fluid leak detection systems. Pressure, temperature and volume measuring and

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................

More information

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF270.UL.D For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic fleece 4. Core

More information

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE Marine Cables FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for over 165 years, always dedicated to connecting

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

Cables for cable carriers and reels SYSTEMS IN MOTION

Cables for cable carriers and reels SYSTEMS IN MOTION Cables for cable carriers and reels SYSTEMS IN MOTION 8e/en 2016 Content PVC flatform cables (H)07VVH6-F H07VVH6-F... 4 PVC flatform cables, shielded YCFLY... 6 Neoprene flatform cables NGFLGÖU UL... 8

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

ÖLFLEX CLASSIC 115 CY

ÖLFLEX CLASSIC 115 CY Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control Low voltage - Energy, cabling, signalling and control FR-N1X1G1 Construction: NF C 32-323 NF C 32-323/1 Fire propagation: NF EN 60332-3-24 NF C 32-070 C1 IEC 60332-3-24 C Flame propagation: NF EN 60332-1-2

More information

Approvals (Norm references)

Approvals (Norm references) ÖLFLEX ROBUST 200 Robust and weatherproofed Wide range of application opportunities Machine tool manufacture, medical technology, laundries, car washing equipment, chemical industry, composting plants,

More information

POWER YOUR MINE WITH TF Kable MINING CABLES AUSTRALIA

POWER YOUR MINE WITH TF Kable MINING CABLES AUSTRALIA POWER YOUR MINE WITH TF Kable MINING CABLES AUSTRALIA Table of Contents rubber CABLES 2 TELE-FONIKA Kable 3 PRODUCTION POTENTIAL 5 1 PRODUCTION MATRIX 6 GENERAL UNDERGROUND COAL MINING CABLES TYPE 209

More information

Item Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE...

Item Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE... Halogen-free ables E-mail: info@sab.com Web site: www.sab.com Item Description Page hapter A A 146 FRN A A 156 FRN Halogen-free wiring with improved fire performance and extended temperature range 300/500

More information

Technical Information

Technical Information Cable Code Designation A cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction. For example: 1st Letter: Insulation: B: Fire resistant tape + insulation (Halogen-free) R:

More information

LOW VOLTAGE c a b l e s

LOW VOLTAGE c a b l e s LOW VOLTAGE c a b l e s MYSORE PLANT SILVASSA PLANT MANUFACTURES A RANGE OF LOW VOLTAGE CABLES AT ITS FACILITIES AT SILVASSA AND MYSORE The Silvassa unit manufactures LV Cables since the year 2000. XLPE/

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

YOUR ENERGY, OUR SYSTEMS, ANYWHERE. Flexible Cables

YOUR ENERGY, OUR SYSTEMS, ANYWHERE. Flexible Cables YOUR ENERGY, OUR SYSTEMS, ANYWHERE Flexible Cables 2010 FLEXIBLE CABLES PRYSMIAN TECHNICAL MANUALS COMMUNICATION CONSTRUCTION DATA & INSTRUMENTATION FIBRE TO THE PREMISES FIRE PERFORMANCE FLEXIBLE CABLES

More information

Standardization IEC /-351/-353. Conductor material

Standardization IEC /-351/-353. Conductor material Low voltage power cables Fire resistant low voltage power cables according to the new demanding IEC -60331 1/2 specifications for power and lighting applications in all ship areas, with reduced diameter

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information