Bock HC Compressors. Semi-hermetic Compressors for Hydrocarbons. engineering for a better world. GEA Refrigeration Technologies
|
|
- Harry Horton
- 6 years ago
- Views:
Transcription
1 Bock HC Compressors Semi-hermetic Compressors for Hydrocarbons engineering for a better world GEA Refrigeration Technologies
2 GEA Bock - More than a compressor Over 75 years ago, when the refrigeration and air-conditioning industry was still in its infancy, our company's founder, Wilhelm Bock, had a vision: he wanted to build first-class and reliable refrigeration machines. In the following decades Bock developed into one of the world's leading manufacturers of refrigeration and airconditioning compressors. Today, GEA Bock offers as part of GEA Refrigeration Technologies the right compressor for all fields of commercial-, industrial-, rail-, bus- and transport refrigeration. In this brochure we present you our semi-hermetic compressors for refrigerant hydrocarbon. Be inspired. By our new products, our established product series and the entire passion that goes into each of our products. Disclaimer This brochure has been produced for you with the greatest of care. Nevertheless it is not possible to rule out mistakes completely. In such cases we cannot assume any liability. The contents correspond to the status on going to print. Deviations cannot be ruled out because of the ongoing developement process for our products. 2 The details are provided as unbinding general information and cannot substitute detailed, individual consultation. Reprints even only of excerpts only allowed with the explicit approval of GEA Bock GmbH. GEA Bock GmbH Gb Subject to change without notice
3 Bock Compressors roduction rogram Semi-hermetic compressors HG (HA) The GEA Bock HG (Hermetic Gas-cooled) range of semi-hermetic compressors offers traditional suction gas-cooled compressor state of the art technology. These compressors of the highest quality standard excel in their running comfort, easy maintenance, efficiency and reliability. Suitable as standard for conventional or chlorine-free HFC refrigerants. The HA (Hermetic Air-cooled) range, specially engineered by GEA Bock, is available for deep-freezing applications, in particular for use with the refrigerants R22 and R4A. ººSingle-stage ººCO2 compressors subcritical ººCO2 compressors transcritical ººR134a compressors ººR7C compressors ººR410A compressors ººTwo-stage compressors ººATEX compressors ººDuplex compressors ººHC compressors ººCompressor units with receiver ººAluminium compressors ººCondenser units air-cooled ºº2-pole compressors Vehicle compressors FK Bock vehicle compressors of the FK range are the result of many years of experience in the domain of mobile cooling systems. The unsurpassed light, compact, robust design and wide r.p.m. range are only some of the outstanding features of this unique product range of two, four and six cylinder compressors. A wide variety of designs can be tailored to suit individual requirements. The so-called K version is a special innovation with a unique valve plate system for maximum requirements in bus and coach air-conditioning systems. ººCompressors for bus and train air-conditioning ººCompressors for transport refrigeration and other applications Open type compressors F The F model series provides modern open type compressors for separate drive systems (using V belts or direct couplings). Load transfer through a V pair. Virtually all drive capacity requirements can be met. Very compact compressor design, robust and easy to handle. Oil pump lubrication as standard. ººSingle-stage compressors ººNH3 compressors ººCompressor units for direct drive ººNH3 Compressor units for direct drive Gb Subject to change without notice 3
4 At a Glance Differences to a standard compressor Electronic motor protection M10 enclosed for installation in the switch cabinet Heat protection thermostat as standard Oil sump heater as standard Special oil charge Synth 68 Type key - compressors for hydrocarbons HG34 / S HC Hydrocarbons Motor variant 3) Number of poles Swept volume luscom 2) 1) HG = Hermetic Gas-cooled (suction gas-cooled) Number of cylinders 2) = Additional declaration for luscom compressors Size Series 1) 3) S = More powerful motor e.g. air-conditioning applications Overview hydrocarbons Refrigerant Composition (Formula) Name OD [R11=1,0] GW (100a) 2 3 [CO 2 =1,0] Safety group 1 Critical value [kg/m 3 ] 2 R290 C 3 H 8 ropane 0 3 A3 0,008 R12 C 3 H 6 ropylene 0 3 A3 0,008 R0a C 4 H 10 Isobutane 0 3 A3 0,011 1 Classification according to EN378-1 or ASHRAE 34 2 According to EN Time horizon 100 years according to ICC II (1996) Basis for Kyoto protocol Gb Subject to change without notice
5 At a Glance Semi-hermetic compressors for hydrocarbons For various applications, such as the field of supermarket refrigeration, hydrocarbons have established as another natural alternative besides CO2. Due to the flammability of hydrocarbons the compressor has some safety related modifications. Special features Based on our current semi-hermetic product range GEA Bock offers now a low-cost compressor variant especially for the use with hydrocarbons. Compressors in HC-design have the following features: - Heat protection thermostat as standard - Oil sump heater as standard - Special oil charge - Motor protection M10 for installation in the switch cabinet Important notes We would like to explicitly state that those compressors are a special edition and the compressors filled with hydrocarbons are to be operated by trained specialists only. lease see assembly instructions for additional important instructions. To ensure the safety measures, an additional agreement, hydrocarbons as refrigerant (GEA Bock-Art. No ) has to be signed. Available models Displacement Hz (14 rpm) HG12/-4 S HC 5, m 3 /h HG12/75-4 HC HG12/75-4 S HC HG12/90-4 HC HG12/90-4 S HC HG12/110-4 HC HG12/110-4 S HC HG22/125-4 HC HG22/125-4 S HC HG22/1-4 HC HG22/1-4 S HC HG22/190-4 HC HG22/190-4 S HC HG34/215-4 HC HG34/215-4 S HC HG34/255-4 HC HG34/255-4 S HC HG34/315-4 HC HG34/315-4 S HC HG34/380-4 HC HG34/380-4 S HC HG4/465-4 HC HG4/465-4 S HC HG4/555-4 HC HG4/555-4 S HC HG4/6-4 HC HG4/6-4 S HC 6, m 3 /h 8,00 m 3 /h 9, m 3 /h 11,10 m 3 /h 13, m 3 /h 16, m 3 /h 18,80 m 3 /h 22,10 m 3 /h 27, m 3 /h 33,10 m 3 /h, m 3 /h 48,20 m 3 /h 56, m 3 /h Available models HG5/725-4 HC HG5/725-4 S HC HG5/8-4 HC HG5/8-4 S HC HG5/945-4 HC HG5/945-4 S HC HG6/ HC HG6/ S HC HG6/12-4 HC HG6/12-4 S HC HG6/ HC HG6/ S HC HG7/ HC HG7/ S HC HG7/18-4 HC HG7/18-4 S HC HG7/ HC HG7/ S HC HG8/24-4 HC HG8/24-4 S HC HG8/28-4 HC HG8/28-4 S HC HG8/ HC HG8/ S HC Displacement Hz (14 rpm) 62,90 m 3 /h 72,20 m 3 /h 82,20 m 3 /h 93, m 3 /h 107, m 3 /h 122, m 3 /h 1, m 3 /h 161, m 3 /h 183, m 3 /h 214, m 3 /h 245,90 m 3 /h 279,80 m 3 /h Additionally, ATEX compressors are available that can be operated with hydrocarbons as well. You can find more information on these compressors in our ATEX brochure Gb Subject to change without notice 5
6 Operating Limits HC operating limits R290 / R12 t c ( C) 66 R0a t c ( C) t Oh <20K 20 - t Oh <20K t +20 C Oh ,5 20 t ( C) o t +20 C Oh t o ( C) 12,5 25 Diagrams for other areas available on request Max. permissible operating pressure (L/H) 1) : 19/28 bar 1) L = low pressure H = high pressure Unlimited application range Supplementary cooling or reduced suction gas temperature Motor version -S- (more powerful motor) The use of other hydrocarbons is permitted only following prior written approval from GEA Bock t O t C t Oh t Oh Evaporating temperature ( C) Condensing temperature ( C) Suction gas temperature ( C) Suction gas superheat (K) Notes Operating limits erformance data Compressor operation is possible within the limits shown on the application diagrams. lease note the coloured areas. Compressor application limits should not be chosen for design purposes or continuous operation. The performance data for the hydrocarbons R290, R0a and R12 are based on 20 K suction gas superheat without liquid subcooling, at Hz power supply frequency. These are computed, preliminary values. Variations cannot be excluded. Conversion factor for Hz = 1, Gb Subject to change without notice
7 erformance Data R290 erformance data Hz Type Cond. Cooling capacity O [W] ower consumption e [kw] HG12/-4 S HC HG12/75-4 HC HG12/75-4 S HC HG12/90-4 HC HG12/90-4 S HC HG12/110-4 HC HG12/110-4 S HC HG22/125-4 HC HG22/125-4 S HC HG22/1-4 HC HG22/1-4 S HC HG22/190-4 HC HG22/190-4 S HC HG34/215-4 HC HG34/215-4 S HC HG34/255-4 HC HG34/255-4 S HC HG34/315-4 HC HG34/315-4 S HC HG34/380-4 HC HG34/380-4 S HC temp. C Evaporating temperature C 12,5 10 7, ,78 0,81 0,83 0,84 0,85 0,83 0,80 0,75 0,69 0,63 0,58 0, ,04 1,04 1,04 1,03 1,00 0,95 0,88 0,81 0,74 0, ,25 1,23 1,21 1,18 1,11 1,04 0,96 0, ,96 1,00 1,03 1,05 1,05 1,03 0,99 0,93 0,86 0,78 0,71 0, ,29 1, 1,29 1,28 1,24 1,17 1,10 1,01 0,92 0, ,55 1,53 1, 1,47 1,38 1,29 1,19 1, ,15 1,20 1,23 1,25 1,26 1,23 1,18 1,11 1,02 0,94 0,85 0, ,54 1,55 1,54 1,53 1,48 1, 1,31 1,21 1,10 1, ,85 1,83 1,79 1,75 1,65 1,54 1,42 1, ,35 1,41 1,44 1,47 1,48 1,45 1,39 1, 1,20 1,10 1,00 0, ,81 1,82 1,81 1,80 1,74 1,65 1,54 1,42 1, 1, ,18 2,15 2,10 2,06 1,94 1,81 1,67 1, , 1,66 1, 1,73 1,74 1,71 1,64 1,54 1,42 1, 1,18 1, ,14 2,15 2,14 2,12 2,05 1,94 1,82 1,67 1,53 1, ,57 2,53 2,49 2,43 2,29 2,13 1,97 1, ,97 2,05 2,10 2,14 2,15 2,11 2,02 1,90 1,75 1, 1,46 1, ,64 2,65 2,64 2,62 2,53 2, 2,24 2,07 1,89 1, ,18 3,13 3,07 3,00 2,83 2,63 2,43 2, ,38 2,47 2,53 2,57 2,59 2,54 2,43 2,28 2,11 1,93 1,76 1, ,18 3,19 3,18 3,15 3,05 2,89 2, 2,49 2,27 2, ,82 3,77 3,69 3,61 3, 3,17 2,92 2, ,71 2,81 2,89 2,93 2,96 2,90 2,77 2, 2,41 2,20 2,00 1, ,62 3,64 3,62 3,59 3,47 3,29 3,07 2,84 2,59 2, ,36 4,29 4,21 4,11 3,88 3,61 3,33 3, ,18 3, 3,39 3,45 3,47 3, 3,26 3,06 2,83 2,59 2,36 2, ,26 4,27 4,26 4,22 4,08 3,87 3,61 3,33 3,05 2, ,12 5,05 4,95 4,83 4,56 4,25 3,91 3, ,93 4,08 4,19 4,26 4,29 4,20 4,03 3,78 3,49 3,20 2,91 2, ,26 5,28 5,26 5,21 5,04 4,78 4,46 4,12 3,76 3, ,33 6,23 6,11 5,97 5,63 5,25 4,84 4, ,77 4,95 5,08 5,16 5,20 5,10 4,88 4,58 4,24 3,87 3,53 3, ,38 6, 6,38 6,32 6,11 5,80 5,41 4,99 4,56 4, ,67 7,56 7,41 7,24 6,83 6,36 5,86 5,37 Relating to 20 C suction gas temperature without liquid subcooling Supplementary cooling or red. suction gas temperature Motor version -S- (more powerful motor) Gb Subject to change without notice 7
8 erformance Data R290 erformance data Hz Type Cond. Cooling capacity O [W] ower consumption e [kw] HG4/465-4 HC HG4/465-4 S HC HG4/555-4 HC HG4/555-4 S HC HG4/6-4 HC HG4/6-4 S HC HG5/725-4 HC HG5/725-4 S HC HG5/8-4 HC HG5/8-4 S HC HG5/945-4 HC HG5/945-4 S HC HG6/ HC HG6/ S HC HG6/12-4 HC HG6/12-4 S HC HG6/ HC HG6/ S HC temp. C Evaporating temperature C 12,5 10 7, ,83 6,06 6,22 6,32 6,37 6,24 5,97 5,61 5,18 4,74 4,32 3, ,80 7,83 7,81 7,74 7,48 7,09 6,62 6,11 5,58 5, ,39 9,25 9,07 8,86 8,36 7,78 7,17 6, ,94 7,21 7, 7,52 7,58 7,42 7,11 6,67 6,17 5,64 5,14 4, ,29 9,32 9,29 9,21 8,90 8,44 7,88 7,27 6,65 6, ,17 11,00 10,79 10,54 9,95 9,26 8,54 7, ,15 8,46 8,69 8,83 8,90 8,72 8,35 7,84 7,25 6,63 6,03 5, ,91 10,94 10,91 10,81 10,45 9,91 9,26 8,54 7,80 7, ,12 12,92 12,67 12,38 11,68 10,88 10,03 9, ,06 9,41 9,65 9,81 9,89 9,69 9,27 8,71 8,05 7,36 6, 6, ,12 12,16 12,12 12,01 11,61 11,02 10,29 9,49 8,67 7, ,58 14,36 14,08 13,76 12,98 12,09 11,14 10, , 10,80 11,08 11,26 11,35 11,12 10,65 10,00 9,24 8,45 7,69 7, ,91 13,96 13,92 13,79 13,33 12,64 11,81 10,89 9,95 9, ,73 16,48 16,17 15,79 14,90 13,87 12,79 11, ,84 12,29 12,62 12,82 12,92 12,66 12,12 11,38 10,52 9,62 8,76 8, ,84 15,89 15,84 15, 15,17 14, 13,44 12, 11,33 10, ,05 18,77 18,41 17,98 16,96 15,80 14,56 13, ,49 14,01 14,38 14,62 14,73 14,43 13,82 12,97 11,99 10,97 9,98 9, ,06 18,12 18,06 17,90 17, 16,41 15,32 14,13 12,92 11, ,72 21,39 20,98 20,49 19,33 18,01 16, 15, ,49 16,09 16,52 16,79 16,91 16,57 15,87 14,90 13,77 12,59 11,47 10, ,74 20,80 20,74 20,55 19,86 18,84 17, 16,23 14,83 13, ,94 24,57 24,09 23,53 22,20 20,68 19,06 17, ,62 18, 18,79 19,10 19,24 18,85 18,05 16,95 15,67 14,33 13,04 11, ,59 23,67 23,59 23,38 22, 21,44 20,02 18,46 16,88 15, ,37 27,94 27,41 26,77 25,26 23,52 21,68 19,86 Relating to 20 C suction gas temperature without liquid subcooling Supplementary cooling or red. suction gas temperature Motor version -S- (more powerful motor) Gb Subject to change without notice
9 erformance Data R290 erformance data Hz Type Cond. Cooling capacity O [W] ower consumption e [kw] HG7/ HC HG7/ S HC HG7/18-4 HC HG7/18-4 S HC HG7/ HC HG7/ S HC HG8/24-4 HC HG8/24-4 S HC HG8/28-4 HC HG8/28-4 S HC HG8/ HC HG8/ S HC temp. C Evaporating temperature C 12,5 10 7, ,24 21,02 21,58 21,94 22,10 21,66 20,73 19,47 18,00 16,46 14,98 13, ,09 27,18 27,10 26,85 25,95 24,62 22,99 21,20 19,38 17, ,59 32,10 31,48,75 29,01 27,02 24,91 22, ,24 24,13 24,77 25,18 25,37 24,86 23,80 22,35 20,66 18,89 17,20 15, ,10 31,21 31,11,83 29,79 28,27 26, 24,34 22,25 20, ,41 36,85 36,14 35, 33, 31,01 28,59 26, ,44 27,45 28,18 28,64 28,86 28,28 27,07 25,42 23, 21,49 19,56 17, ,38 35, 35,39 35,07 33,89 32,15,03 27,69 25,31 23, ,55 41,92 41,11,15 37,88 35,28 32,52 29, ,86 32,04 32,89 33,43 33,69 33,01 31, 29,67 27,43 25,08 22,84 20, , 41,43 41,,93 39,56 37,53 35,05 32,32 29,55 26, ,67 48,93 47,98 46,87 44,22 41,18 37,96 34, ,41 36,77 37,74 38,36 38,65 37,87 36,26 34,05 31,48 28,78 26,20 23, ,39 47,54 47,39 46,97 45,39 43,06,21 37,08 33,90, ,99 56,14 55,06 53,78,74 47,25 43,56 39, ,29 41,84 42,95 43,65 43,98 43,09 41,26 38,74 35,82 32,75 29,82 27, ,92 54,10 53,93 53,44 51,65 49,00 45,76 42,19 38,58 35, ,85 63,88 62,65 61,19 57,73 53,77 49,57 45, Relating to 20 C suction gas temperature without liquid subcooling Supplementary cooling or red. suction gas temperature Motor version -S- (more powerful motor) Gb Subject to change without notice 9
10 erformance Data R12 erformance data Hz Type HG12/-4 S HC HG12/75-4 HC HG12/75-4 S HC HG12/90-4 HC HG12/90-4 S HC HG12/110-4 HC HG12/110-4 S HC HG22/125-4 HC HG22/125-4 S HC HG22/1-4 HC HG22/1-4 S HC HG22/190-4 HC HG22/190-4 S HC HG34/215-4 HC HG34/215-4 S HC HG34/255-4 HC HG34/255-4 S HC HG34/315-4 HC HG34/315-4 S HC HG34/380-4 HC HG34/380-4 S HC Cond temp. C Cooling capacity O [W] Evaporating temperature C ower consumption e [kw] 12,5 10 7, ,93 0,95 0,97 0,99 1,00 0,99 0,97 0,92 0,87 0,80 0,73 0, ,24 1,24 1,24 1,23 1,21 1,16 1,10 1,03 0,95 0, ,51 1,49 1,47 1,44 1,38 1, 1,21 1, ,15 1,18 1,21 1,23 1,24 1,23 1,20 1,15 1,08 0,99 0,90 0, ,54 1,54 1,54 1,53 1, 1,44 1,36 1,27 1,17 1, ,87 1,85 1,82 1,79 1,71 1,61 1, 1, ,37 1,41 1,44 1,46 1,48 1,47 1,43 1,37 1,29 1,19 1,08 0, ,83 1,84 1,84 1,83 1,79 1,72 1,63 1,52 1, 1, ,24 2,21 2,18 2,14 2,04 1,93 1,79 1, ,61 1,66 1,69 1,72 1,74 1,73 1,68 1,61 1,51 1,39 1,26 1, ,15 2,16 2,16 2,15 2,10 2,02 1,91 1,79 1,65 1, ,63 2, 2,56 2,51 2, 2,26 2,10 1, ,90 1,96 2,00 2,03 2,06 2,04 1,98 1,90 1,78 1,65 1,49 1, ,54 2,55 2,55 2,53 2,48 2,38 2,26 2,11 1,94 1, ,10 3,07 3,02 2,97 2,83 2,67 2,49 2, ,35 2,42 2,47 2,51 2,54 2,52 2,45 2,34 2,20 2,03 1,84 1, ,14 3,15 3,15 3,13 3,06 2,94 2,79 2,61 2, 2, ,83 3,79 3,73 3,66 3, 3, 3,07 2, ,83 2,91 2,98 3,02 3,06 3,03 2,95 2,82 2,65 2,45 2,22 1, ,78 3,79 3,79 3,77 3,68 3,54 3,36 3,14 2,89 2, ,61 4,56 4,49 4,41 4,21 3,97 3,69 3, ,22 3,32 3,39 3,44 3,48 3,45 3,36 3,21 3,02 2,79 2,53 2, ,31 4,32 4,32 4,29 4,20 4,04 3,83 3,58 3,29 2, ,26 5,20 5,12 5,03 4,80 4,52 4,21 3, ,79 3,90 3,98 4,04 4,09 4,06 3,95 3,78 3,55 3,28 2,97 2, ,06 5,08 5,07 5,05 4,93 4,75 4, 4,21 3,87 3, ,18 6,11 6,02 5,91 5,64 5,32 4,95 4, ,68 4,82 4,92 5,00 5,06 5,02 4,88 4,67 4,39 4,05 3,67 3, ,26 6,28 6,27 6,23 6,09 5,86 5,56 5,19 4,78 4, ,63 7,54 7,43 7, 6,97 6,57 6,11 5, ,68 5,84 5,97 6,06 6,13 6,08 5,92 5,66 5,32 4,91 4,45 3, ,58 7,61 7, 7,56 7,39 7,11 6,74 6, 5,79 5, ,25 9,15 9,01 8,85 8,45 7,97 7,41 6,80 Relating to 20 C suction gas temperature without liquid subcooling Supplementary cooling or red. suction gas temperature Motor version -S- (more powerful motor) Gb Subject to change without notice
11 erformance Data R12 erformance data Hz Type Cond. Cooling capacity O [W] ower consumption e [kw] HG4/465-4 HC HG4/465-4 S HC HG4/555-4 HC HG4/555-4 S HC HG4/6-4 HC HG4/6-4 S HC HG5/725-4 HC HG5/725-4 S HC HG5/8-4 HC HG5/8-4 S HC HG5/945-4 HC HG5/945-4 S HC HG6/ HC HG6/ S HC HG6/12-4 HC HG6/12-4 S HC HG6/ HC HG6/ S HC temp. C Evaporating temperature C 12,5 10 7, ,94 7,15 7, 7,41 7, 7,44 7,24 6,93 6,51 6,01 5,45 4, ,28 9,31 9, 9,25 9,04 8, 8,25 7,71 7,09 6, ,32 11,19 11,03 10,83 10,34 9,75 9,07 8, ,27 8,51 8,69 8,82 8,93 8,86 8,62 8,24 7,75 7,15 6,48 5, ,04 11,08 11,07 11,01 10,76 10,35 9,82 9,17 8,44 7, ,48 13,32 13,12 12,89 12,31 11, 10,79 9, ,71 9,99 10,21 10,36 10,49 10, 10,12 9,68 9,10 8, 7,61 6, ,97 13,01 13,00 12,93 12,63 12,16 11,53 10,77 9,91 8, ,83 15,64 15,41 15,13 14,45 13,62 12,67 11, ,79 11,10 11,34 11,51 11,65 11,56 11,25 10,76 10,11 9,33 8,46 7, ,41 14,46 14,44 14,36 14,04 13,51 12,81 11,97 11,01 9, ,59 17,38 17,13 16,82 16,06 15,14 14,09 12, ,38 12,74 13,02 13,21 13,38 13,27 12,91 12,35 11, 10,71 9,71 8, ,54 16, 16,58 16,49 16,11 15,51 14,71 13,74 12,64 11, ,19 19,95 19,66 19, 18,43 17,38 16,17 14, ,10 14,51 14,82 15,04 15,23 15,10 14, 14,06 13,21 12,20 11,05 9, ,84 18,90 18,87 18,77 18,35 17,66 16,74 15,64 14,39 13, ,98 22,72 22,38 21,98 20,99 19,78 18,41 16, ,07 16,54 16,89 17,15 17,36 17,22 16,76 16,02 15,06 13,90 12, 11, ,47 21,54 21,51 21, 20,91 20,13 19,09 17,83 16, 14, ,20 25,90 25,51 25,05 23,92 22,55 20,98 19, ,45 18,99 19, 19,69 19,94 19,77 19,24 18, 17,29 15,97 14,47 12, ,66 24,74 24,71 24,57 24,02 23,12 21,92 20,47 18,83 17, ,09 29,74 29, 28,77 27,47 25,90 24,09 22, ,99 21, 22,07 22, 22,68 22,49 21,89 20,93 19,67 18,16 16,46 14, ,05 28,14 28,10 27,95 27,32 26,29 24,93 23,29 21,42 19, ,22 33,83 33,33 32,73 31,25 29,46 27,41 25,15 Relating to 20 C suction gas temperature without liquid subcooling Supplementary cooling or red. suction gas temperature Motor version -S- (more powerful motor) Gb Subject to change without notice 11
12 erformance Data R12 erformance data Hz Type Cond. Cooling capacity O [W] ower consumption e [kw] HG7/ HC HG7/ S HC HG7/18-4 HC HG7/18-4 S HC HG7/ HC HG7/ S HC HG8/24-4 HC HG8/24-4 S HC HG8/28-4 HC HG8/28-4 S HC HG8/ HC HG8/ S HC temp. C Evaporating temperature C 12,5 10 7, ,11 24,81 25,35 25,73 26,05 25,83 25,14 24,04 22,59 20,86 18,91 16, ,22 32,32 32,28 32,11 31,38,20 28,64 26,75 24,61 22, ,31 38,86 38,28 37,59 35,90 33,84 31,48 28, ,68 28,48 29,10 29,54 29,90 29,66 28,86 27, 25,94 23,95 21,71 19, ,98 37,10 37,06 36,86 36,02 34,67 32,88,71 28,25 25, ,13 44,61 43,95 43,15 41,21 38,85 36,14 33, ,48 32, 33,10 33, 34,02 33,73 32,83 31, 29, 27,24 24,69 21, ,07 42,21 42,16 41,93,98 39,44 37, 34,94 32,13 29, ,33,74 49,99 49,09 46,88 44,19 41,11 37, ,75 37,82 38,64 39,22 39,71 39,38 38,32 36,65 34,44 31,80 28,82 25, ,11 49,27 49,21 48,94 47,83 46,04 43,65,78 37, 33, ,92 59,23 58,35 57, 54,71 51,58 47,99 44, ,17 43, 44,34 45,00 45,56 45,18 43,97 42,05 39,52 36,49 33,07 29, ,35 56,53 56,46 56,16 54,88 52,83,09 46,79 43,03 38, ,75 67,96 66,95 65,74 62,78 59,19 55,06, ,98 49,38,45 51,21 51,84 51,41,04 47,85 44,96 41,52 37,63 33, ,12 64,32 64,25 63,90 62,45,11 57,00 53,24 48,97 44, ,23 77,33 76,18 74,81 71,44 67,35 62,66 57,49 Relating to 20 C suction gas temperature without liquid subcooling Supplementary cooling or red. suction gas temperature Motor version -S- (more powerful motor) Gb Subject to change without notice
13 erformance Data R0a erformance data Hz Type HG12/-4 S HC HG12/75-4 HC HG12/90-4 HC HG12/110-4 HC HG22/125-4 HC HG22/1-4 HC HG22/190-4 HC Cond. temp. C Relating to 20 C suction gas temperature without liquid subcooling Cooling capacity O [W] Evaporating temperature C ower consumption e [kw] 12,5 10 7, ,37 0,37 0,37 0,37 0,36 0,34 0, ,45 0,44 0,44 0,43 0, 0,37 0, ,52 0,51 0, 0,48 0,44 0,41 0, , 0,57 0,55 0,53 0,48 0,43 0, ,66 0,63 0, 0,56 0, 0,45 0, ,46 0,46 0,46 0,46 0,44 0,42 0, ,56 0,55 0,54 0,53 0, 0,46 0, ,65 0,63 0,61 0,59 0,55 0, 0, ,74 0,71 0,68 0,65 0,59 0,53 0, ,82 0,78 0,74 0, 0,62 0,55 0, ,55 0,55 0,55 0,55 0,53 0, 0, ,66 0,66 0,64 0,63 0, 0,55 0, ,78 0,76 0,73 0,71 0,66 0, 0, ,88 0,85 0,82 0,78 0,71 0,64 0, ,98 0,93 0,88 0,84 0,75 0,66 0, ,64 0,65 0,65 0,64 0,62 0,59 0, ,78 0,77 0,76 0,74 0, 0,65 0, ,91 0,89 0,86 0,83 0,77 0,71 0, ,04 1,00 0,96 0,92 0,83 0,75 0, ,15 1,09 1,04 0,98 0,88 0,78 0, ,76 0,76 0,77 0,76 0,74 0, 0, ,92 0,91 0,89 0,87 0,83 0,77 0, ,08 1,05 1,02 0,98 0,91 0,83 0, ,22 1,18 1,13 1,08 0,98 0,88 0, ,35 1,29 1,23 1,16 1,03 0,92 0, ,94 0,94 0,94 0,94 0,91 0,86 0, ,14 1,12 1,10 1,08 1,02 0,95 0, ,33 1, 1,26 1,22 1,12 1,03 0, ,51 1,45 1, 1,34 1,21 1,09 0, ,67 1,59 1,51 1,43 1,28 1,13 1, ,13 1,14 1,14 1,13 1,09 1,04 0, ,37 1,35 1,33 1, 1,23 1,14 1, , 1,56 1,51 1,46 1,35 1,24 1, ,82 1,75 1,68 1,61 1,46 1,31 1, ,01 1,92 1,82 1,73 1,54 1,36 1,20 Supplementary cooling or red. suction gas temperature Gb Subject to change without notice 13
14 erformance Data R0a erformance data Hz Type HG34/215-4 HC HG34/255-4 HC HG34/315-4 HC HG34/380-4 HC HG4/465-4 HC HG4/555-4 HC HG4/6-4 HC Cond. temp. Relating to 20 C suction gas temperature without liquid subcooling 14 C Cooling capacity O [W] Evaporating temperature C ower consumption e [kw] 12,5 10 7, ,28 1, 1, 1,29 1,25 1,18 1, ,56 1,54 1,52 1,48 1, 1, 1, ,83 1,78 1,73 1,67 1,55 1,41 1, ,08 2,00 1,92 1,84 1,67 1, 1, , 2,19 2,08 1,98 1,76 1,56 1, ,51 1,52 1,52 1,51 1,47 1,39 1, ,83 1,81 1,78 1,74 1,65 1,53 1, ,15 2,10 2,03 1,97 1,82 1,67 1, ,45 2,36 2,26 2,16 1,97 1,77 1, ,71 2,58 2,46 2,33 2,08 1,84 1, ,86 1,88 1,88 1,87 1,81 1,71 1, ,26 2,24 2,20 2,15 2,03 1,89 1, ,65 2,58 2, 2,42 2,23 2,04 1, ,00 2,89 2,77 2,65 2,41 2,16 1, ,32 3,16 3,00 2,84 2,53 2,24 1, ,26 2,28 2,28 2,27 2,20 2,08 1, ,75 2,71 2,67 2,61 2,47 2,29 2, ,22 3,13 3,04 2,94 2,72 2,49 2, ,66 3,52 3,38 3,23 2,93 2,64 2, ,04 3,85 3,66 3,47 3,09 2,74 2, ,77 2,79 2,79 2,77 2,69 2,54 2, ,36 3,32 3,26 3,19 3,02 2,80 2, ,93 3,83 3,72 3,59 3,32 3,04 2, ,47 4, 4,13 3,95 3,58 3,23 2, ,94 4,71 4,47 4,24 3,78 3,34 2, ,29 3,32 3,32 3, 3,20 3,03 2, ,00 3,95 3,88 3,80 3,59 3,34 3, ,68 4,56 4,42 4,27 3,95 3,62 3, ,32 5,12 4,91 4, 4,27 3,84 3, ,88 5, 5,32 5,04 4,49 3,98 3, ,87 3,90 3,90 3,88 3,75 3,56 3, ,69 4,64 4,56 4,46 4,21 3,92 3, , 5,35 5,19 5,02 4,64 4,25 3, ,24 6,01 5,77 5,52 5,01 4,51 4, ,90 6,58 6,25 5,92 5,28 4,67 4,12 Supplementary cooling or red. suction gas temperature Gb Subject to change without notice
15 erformance Data R0a erformance data Hz Type Cond. Cooling capacity O [W] ower consumption e [kw] HG5/725-4 HC HG5/8-4 HC HG5/945-4 HC HG6/ HC HG6/12-4 HC HG6/ HC temp. C Evaporating temperature C 12,5 10 7, , 4,33 4,34 4,31 4,17 3,95 3, ,21 5,15 5,07 4,96 4,68 4,35 4, ,11 5,95 5,77 5,58 5,16 4,72 4, ,94 6,68 6,41 6,13 5,57 5,01 4, ,67 7,31 6,94 6,58 5,86 5,19 4, ,93 4,97 4,98 4,94 4,79 4,54 4, ,99 5,92 5,82 5,69 5,38 5,00 4, ,01 6,83 6,62 6, 5,92 5,42 4, ,97 7,67 7,36 7,04 6,39 5,75 5, ,81 8,39 7,97 7,55 6,73 5,96 5, ,61 5,66 5,67 5,63 5,45 5,16 4, ,81 6,74 6,62 6,48 6,12 5,69 5, ,98 7,77 7,54 7,29 6,74 6,17 5, ,07 8,73 8,38 8,01 7,27 6,55 5, ,03 9,55 9,08 8, 7,66 6,78 5, , 6,45 6,46 6,42 6,21 5,89 5, ,77 7,68 7,55 7,39 6,98 6,49 5, ,10 8,86 8, 8,31 7,69 7,03 6, ,34 9,95 9,55 9,13 8,29 7,46 6, ,43 10,89 10,35 9,80 8,74 7,73 6, ,35 7,41 7,42 7,37 7,13 6,76 6, ,92 8,82 8,67 8,48 8,01 7,45 6, ,45 10,18 9,87 9,54 8,83 8,07 7, ,87 11,43 10,96 10,49 9,52 8,57 7, ,12 12, 11,88 11,26 10,03 8,87 7, ,36 8,43 8,44 8,38 8,12 7,69 7, ,15 10,03 9,86 9,65 9,11 8,47 7, ,89 11,58 11,23 10,86 10,04 9,19 8, , 13,00 12,47 11,93 10,83 9,75 8, ,93 14,22 13,51 12,80 11,41 10,10 8,91 Relating to 20 C suction gas temperature without liquid subcooling Supplementary cooling or red. suction gas temperature Gb Subject to change without notice 15
16 erformance Data R0a erformance data Hz Type HG7/ HC HG7/18-4 HC HG7/ HC HG8/24-4 HC HG8/28-4 HC HG8/ HC Cond. temp. C Cooling capacity O [W] Evaporating temperature C ower consumption e [kw] 12,5 10 7, , 9,68 9,69 9,63 9,32 8,83 8, ,66 11,52 11,33 11,08 10,47 9,73 8, ,65 13, 12,90 12,47 11,53 10,55 9, ,51 14,93 14,33 13,71 12,44 11,20 10, ,15 16,34 15,52 14,71 13,11 11, 10, ,02 11,12 11,12 11,05 10, 10,14 9, ,38 13,23 13,00 12,72 12,02 11,17 10, ,67 15,26 14,81 14,31 13,24 12,11 10, ,81 17,14 16,45 15,73 14,28 12,86 11, ,69 18,76 17,82 16,88 15,05 13,31 11, ,54 12,65 12,65 12,57 12,17 11,53 10, ,22 15,05 14,79 14,47 13,67 12,71 11, ,83 17,36 16,85 16,28 15,06 13,78 12, ,25 19, 18,71 17,90 16,25 14,62 13, ,39 21,34 20,27 19,21 17,12 15,14 13, ,64 14,76 14,77 14,67 14,21 13,46 12, ,77 17,56 17,27 16,89 15,95 14,84 13, ,81 20,27 19,66 19,01 17,58 16,08 14, ,64 22,76 21,84 20,89 18,96 17,07 15, ,14 24,90 23,66 22,42 19,98 17,68 15, ,80 16,94 16,95 16,84 16, 15,45 14, ,39 20,15 19,81 19,38 18,31 17,03 15, ,88 23,26 22,56 21,81 20,17 18,45 16, ,13 26,11 25,06 23,97 21,76 19,59 17, ,99 28,58 27,15 25,72 22,92 20,28 17, ,11 19,27 19,28 19,16 18,55 17,58 16, ,20 22,93 22,54 22,06 20,83 19,37 17, ,17 26,46 25,67 24,82 22,96 21,00 19, ,87 29,71 28,51 27,28 24,76 22,29 19, ,13 32,52,89 29,27 26,08 23,08 20,37 Relating to 20 C suction gas temperature without liquid subcooling Supplementary cooling or red. suction gas temperature Gb Subject to change without notice
17 Technical Data HC Number of cylinders Displacement / Hz (14 / 17 rpm) Electrical data Weight Connections 6 Oil charge Voltage Max. Max. power Starting Discharge Suction working consumption current line line current (rotor locked) DV SV Type m³/h A kw A kg mm I inch mm I inch Ltr. / Y / Y HG12/-4 S HC 2 5, / 6, 3 6,8 / 3,9 2,2 / I 1 / 2 16 I 5 0,8 HG12/75-4 HC 2 6,,10 3 7,1,1 2,3 / I 1 / 2 16 I 5 0,8 HG12/75-4 S HC 2 6,,10 3 8,0,6 2,6 43 / I 1 / 2 16 I 5 0,8 HG12/90-4 HC 2 8,00 / 9, 3 8,5,9 2,8 43 / I 1 / 2 16 I 5 0,8 HG12/90-4 S HC 2 8,00 / 9, 3 8,8 / 5,1 2,9 45 / I 1 / 2 16 I 5 0,8 HG12/110-4 HC 2 9, / 11, 3 9,2 / 5,3 3,1 43 / I 1 / 2 16 I 5 0,8 HG12/110-4 S HC 2 9, / 11, 3 10,6 / 6,1 3,6 45 / I 1 / 2 16 I 5 0,8 HG22/125-4 HC 2 11,10 / 13, 3 9,3 / 5,4 3,0 69 / I 5 22 I 7 1,0 HG22/125-4 S HC 2 11,10 / 13, 3 10,8 / 6,2 3,6 69 / I 5 22 I 7 1,0 HG22/1-4 HC 2 13,, 3 11,1 / 6,4 3,7 69 / I 5 22 I 7 1,0 HG22/1-4 S HC 2 13,, 3 13,1 / 7,6 4,4 87 / I 5 22 I 7 1,0 HG22/190-4 HC 2 16, / 19, ,8,0 4,8 69 / I 5 22 I 7 1,0 HG22/190-4 S HC 2 16, / 19, ,2 / 9,4 5,6 87 / I 5 22 I 7 1,0 HG34/215-4 HC 4 18,80 / 22, 3 14,0,1 4,8 87 / I 7 28 I 1 1 1,3 HG34/215-4 S HC 4 18,80 / 22, 3 18,3 / 10,5 6,0 132 / I 7 28 I 1 1 1,3 HG34/255-4 HC 4 22,10 / 26, 3 17,0 / 9,8 6,0 87 / I 7 28 I 1 1 1,3 HG34/255-4 S HC 4 22,10 / 26, 3 21,1 / 12,2 7,2 132 / I 7 28 I 1 1 1,3 HG34/315-4 HC 4 27, / 32, ,1 / 12,2 7,4 111 / I 7 28 I 1 1 1,3 HG34/315-4 S HC 4 27, / 32, ,5 / 14,7 8,9 132 / I 7 28 I 1 1 1,3 HG34/380-4 HC 4 33,10 / 39, 3 26,1 / 15,1 9,3 111 / I 7 28 I 1 1 1,3 HG34/380-4 S HC 4 33,10 / 39, 3 31,2 / 18,0 11,1 132 / I 7 28 I 1 1 1, Gb Subject to change without notice 17
18 Technical Data HC Number of cylinders Displacement / Hz (14 / 17 rpm) Electrical data Weight Connections 6 Oil charge Voltage Max. Max. power Starting Discharge Suction working consumption current line line current (rotor locked) DV SV Type m³/h A kw A kg mm I Zoll mm I Zoll Ltr. * W 1+2 *W1 / W 1+2 HG4/465-4 HC 4, 8, ,0 57 / I I 1 3 2,7 HG4/465-4 S HC 4, 8, ,0 82 / I I 1 3 2,7 HG4/555-4 HC 4 48,20 / 57, ,9 82 / I I 1 3 2,7 HG4/555-4 S HC 4 48,20 / 57, ,2 107 / I I 1 3 2,7 HG4/6-4 HC 4 56, / 67, ,7 82 / I I 1 5 2,7 HG4/6-4 S HC 4 56, / 67, ,4 107 / I I 1 5 2,7 HG5/725-4 HC 4 62,90 / 75, ,5 82 / I I 1 5 3,6 HG5/725-4 S HC 4 62,90 / 75, ,4 107 / I I 1 5 3,6 HG5/8-4 HC 4 72,20 6, ,9 82 / I I 1 5 3,6 HG5/8-4 S HC 4 72,20 6, , I I 1 5 3,6 HG5/945-4 HC 4 82,20 / 98, ,6 107 / I I 2 1 3,6 HG5/945-4 S HC 4 82,20 / 98, , I I 2 1 3,6 HG6/ HC 4 93, / 112, ,3 149 / I I 2 1 3,6 HG6/ S HC 4 93, / 112, ,0 172 / I I 2 1 3,6 HG6/12-4 HC 4 107, / 129, ,5 172 / I I 2 1 3,6 HG6/12-4 S HC 4 107, / 129, ,0 204 / I I 2 1 3,6 HG6/ HC 4 122, / 146, ,6 172 / I I 2 1 3,6 HG6/ S HC 4 122, / 146, ,6 204 / I I 2 1 3,6 HG7/ HC 6 1, 8, ,7 223 / I I 2 1 4,5 HG7/ S HC 6 1, 8, ,3 268 / I I 2 1 4,5 HG7/18-4 HC 6 161, / 193, ,6 268 / I I 2 1 4,5 HG7/18-4 S HC 6 161, / 193, , I I 2 1 4,5 HG7/ HC 6 183, / 220, , I I 2 5 4,5 HG7/ S HC 6 183, / 220, 5 115,5 344 / I I 2 5 4,5 HG8/24-4 HC 8 214, / 257, ,0 274 / I I 3 1 9,0 HG8/24-4 S HC 8 214, / 257, ,5 475 / I I 3 1 9,0 HG8/28-4 HC 8 245,90 / 295, ,5 475 / I I 3 1 9,0 HG8/28-4 S HC 8 245,90 / 295, ,5 520 / I I 3 1 9,0 HG8/ HC 8 279,80 / 335, ,3 475 / I I 3 1 9,0 HG8/ S HC 8 279,80 / 335, ,2 520 / I I 3 1 9,0 * W = art Winding, motors for part winding start 1 = 1. part winding 2 = 2. part winding Gb Subject to change without notice
19 Technical Data Explanations 1 2 Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request. - The specifications for max. power consumption apply for Hz operation. For Hz operation, the specifications have to be multiplied by the factor 1.2. The max. working current remains unchanged. - Take account of the max. operating current / max. power consumption when designing contactors, leads and fuses. Switches: service category AC3 Oil sump heater V / Hz HG12..HC, HG22..HC, HG34..HC: -120 W TC heater, self-regulating, installation in housing bore Oil sump heater 2 V / Hz HG4..HC: 80 W HG5...HC, HG6...HC, HG7...HC: 1 W HG8..HC: 200 W ermanently set version, installation in immersion sleeve V / V Y Hz V -480 V Y Hz V Y/YY Hz W V Y/YY Hz W W = art Winding, motors for part winding start (no start unloaders required) - Winding ratio: HG4, HG5, HG6 = 66% / 33% - Designs for Y/ on request V / YYY Hz W V / YYY Hz W W = art Winding, motors for part winding start (no start unloaders required) - Winding ratio: HG7, HG8 = % / % - Designs for Y/ on request 6 For soldering connections Gb Subject to change without notice 19
20 Dimensions and Connections HG12 HC HG12/-4 S HC HG12/75-4 HC HG12/75-4 S HC HG12/90-4 HC HG12/90-4 S HC HG12/110-4 HC HG12/110-4 S HC L1 B1 ca DV B A ca.115 SV 1) A1 ca E F H,D1 K,O 66 J1 ca ca.415 4x HG22 HC HG22/125-4 HC HG22/125-4 S HC HG22/1-4 HC HG22/1-4 S HC HG22/190-4 HC HG22/190-4 S HC 88 L1 DV B1 B A ca.135 ca ca.4 SV 1) A1 ca B E F 4x ca.2 H,D1 K,O J1 1) SV 90 rotatable Centre of gravity Dimensions in mm Gb Subject to change without notice
21 Dimensions and Connections HG34 HC HG34/215-4 HC HG34/215-4 S HC HG34/255-4 HC HG34/255-4 S HC HG34/315-4 HC HG34/315-4 S HC HG34/380-4 HC HG34/380-4 S HC L1 ca.285 DV B1 H,D1 ca.135 A1 SV 1) A1 ca (271) 115 A B E F K,O J1 46 (43) 79 (74) ca ca.515 (510) 4x Dimensions in ( ) for HG34/215-4 (S) HC and (S) HC HG4 HC HG4/465-4 HC HG4/465-4 S HC HG4/555-4 HC HG4/555-4 S HC HG4/6-4 HC HG4/6-4 S HC ca.180 DV L A L1 SV 1) A1 ca D F J1 ca B B1 C E H D1 O K X ca (535) ca.725 (690) 4x ÖV 25 Dimensions in ( ) for HG4/465-4 (S) HC and (S) HC 1) SV 90 rotatable Centre of gravity Dimensions in mm - Dimensions for view X see page Gb Subject to change without notice 21
22 Dimensions and Connections HG5 HC HG5/725-4 HC HG5/725-4 S HC HG5/8-4 HC HG5/8-4 S HC HG5/945-4 HC HG5/945-4 S HC DV B A N ca B B1 ca.180 ca ca.645 (6) ca. 8 (815) SV A1 1) ca L1 D J1 F 4x ÖV 25 C E H D1 O K X Dimensions in ( ) for HG5/725-4 (S) HC and 8-4 (S) HC HG6 HC HG6/ HC HG6/ S HC HG6/12-4 HC HG6/12-4 S HC HG6/ HC HG6/ S HC DV B A N ca ca.8 SV A1 1) ca.185 ca D F J1 ca B B1 4x ÖV 25 L1 C E H D1 O X K 1) SV 90 rotatable Centre of gravity Dimensions in mm - Dimensions for view X see page Gb Subject to change without notice
23 Dimensions and Connections HG7 HC HG7/ HC HG7/ S HC HG7/18-4 HC HG7/18-4 S HC HG7/ HC HG7/ S HC ca.510 1) DV B N A SV A2 B1 A1 B 90 1 ca ca.8 ca ca D F J1 4x ÖV L1 C E H D1 X K,O HG8 HC HG8/24-4 HC HG8/24-4 S HC HG8/28-4 HC HG8/28-4 S HC HG8/ HC HG8/ S HC DV 1) B N A SV A2 ca.580 B B1 A1 L1 C ca ca.9 ca ca D D1 F J1 4x 13,5 3 4 E H K,O X ÖV1 1) SV 90 rotatable Centre of gravity Dimensions in mm - Dimensions for view X see page Gb Subject to change without notice 23
24 Dimensions and Connections View X ossibility to connect oil level regulator HG4...HC, HG5...HC, HG6...HC, HG7...HC, HG8...HC Three-hole connection for oil level regulator make ESK, AC+R, CARLY (3x M6, 10 deep) Three-hole connection for oil level regulator make TRAXOIL (3 x M6 x 10 deep) 124 Ø 47,6 Dimensions in mm Gb Subject to change without notice
25 Dimensions and Connections Connections HG12..HC HG22..HC HG34..HC HG4..HC HG5..HC HG6..HC HG7..HC HG8..HC SV DV A A1 A2 B B1 C D D1 E Suction line Discharge line Connection suction side, not lockable Connection suction side, lockable Connection suction side, not lockable Connection suction side, not loackable Connection discharge side, lockable Connection oil pressure safety switch OIL Connection oil pressure safety switch L Connection oil return from oil separator Connection oil pressure gauge please refer to Technical data page " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 7 " UNF " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 7 " UNF " UNF " UNF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 7 " UNF F Oil drain M 8 M 10 M 10 M 22 x 1,5 M 22 x 1,5 M 22 x 1,5 M 22 x 1,5 M 22 x 1,5 H Oil charge plug 1 " NTF 1 " NTF 1 " NTF M 22 x 1,5 M 22 x 1,5 M 22 x 1,5 M 22 x 1,5 M 33 x 2 J1 Oil sump heater Ø 15 mm 1) Ø 15 mm 1) Ø 15 mm 1) M 22 x 1,5 M 22 x 1,5 M 22 x 1,5 M 22 x 1,5 M 22 x 1,5 K L1 N O ÖV Sight glass Thermal protection thermostat Connection capacity controller Connection oil level regulator Connection oil service valve 1 1 " - 18 UNEF 1 1 " - 18 UNEF 1 1 " - 18 UNEF 4 hole M 6 4 hole M 6 4 hole M 6 3 hole M 6 3 hole M 6 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF M 48 x 1,5 M 45 x 1,5 M 45 x 1,5 M 45 x 1,5 M 45 x 1,5 1 1 " - 18 UNEF 1 1 " - 18 UNEF 1 1 " - 18 UNEF " NTF 1 " NTF 1 " NTF 1 " NTF - ÖV1 Oil service valve " UNF Connection oil pressure differential sensor Connection oil temperature sensor 1) = ossibility of connection of oil sump heater 1 Dimensions see view X page M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1, " NTF 1 " NTF 1 " NTF 1 " NTF 1 " NTF Attention: Electric, respectively electronic components of the standard extent of delivery, from the accessories or that are obtained otherwise have to be handled and mounted in such a way that the corresponding regulations for the use of hydrocarbons are fulfilled Gb Subject to change without notice 25
26 Scope of Supply Scope of supply Semi-hermetic two cylinder reciprocating compressor with drive motor for direct start V / V Y Hz V -480 V Y Hz Single-section compressor housing with integrated electric motor Semi-hermetic four cylinder reciprocating compressor with drive motor for direct start V / V Y Hz V -480 V Y Hz Single-section compressor housing with integrated electric motor Semi-hermetic four cylinder reciprocating compressor with drive motor for part winding start V Y/YY Hz V Y/YY Hz Motoreinheit am Verdichtergehäuse angeflanscht Semi-hermetic six cylinder reciprocating compressor with drive motor for part winding start V / YYY Hz V / YYY Hz Single-section compressor housing with integrated electric motor Semi-hermetic eight cylinder reciprocating compressor with drive motor for part winding start V / YYY Hz V / YYY Hz Single-section compressor housing with integrated electric motor Winding protection with TC resistor sensors. Electronic triggering unit Bock M10 for installation in switch cabinet (enclosed) Individual control of cylinder heads with thermal protection thermostats Oil pump cover with screwed connection for differential oil pressure sensor (INT 2 Kriwan make) Connection possibility of oil level controllers makes ESK, AC+R, CARLY or Traxoil Oil sump heater V / Hz, -120 W TC heater, self regulating Oil sump heater 2 V / Hz, 80 W Oil sump heater 2 V / Hz, 1 W Oil sump heater 2 V / Hz, 200 W Oil service valve Oil charge: HG: Fuchs Reniso Synth 68 Sight glass Two sight glasses Three sight glasses repared for capacity regulator (1 cylinder cover) repared for capacity regulator (2 cylinder cover) repared for capacity regulator (3 cylinder cover) Decompression valve Suction and discharge line valve Inert gas charge 4 anti-vibration pads enclosed 1) Adapter neccessary. 2) Adapter for Traxoil neccessary. HG12...HC 1) HG22...HC HG34...HC HG4...HC HG5...HC HG6...HC HG7...HC HG8...HC 1) 1) 2) 2) 2) 2) 2) Gb Subject to change without notice
27 Accessories Accessories 1 Start unloader 2 V / Hz, I65, without check valve HG12...HC HG22...HC HG34...HC HG4...HC HG5...HC HG6...HC HG7...HC HG8...HC 2 Start unloader by means of a Bock-ESS (Electronic Soft Start) I20 (Connection clamps I00) for installation in switch cabinet 1) 3 Capacity regulator 2 V / Hz, I65 1 Capacity regulator = % residual capacity Capacity regulator 2 V / Hz, I Capacity regulator = 66/33% residual capacity Capacity regulator 2 V / Hz, I Capacity regulator = 75//25% residual capacity 4 Continuously variable speed control by means of a Bock EFCe (Electronic Frequency Control for individual installation) I54 5 Bock ES (Electronic Single hase) phase converter from single to three phase AC for installation in switch cabinet, I20 6 Cylinder cover prepared for capacity regulator 7 Oil differential pressure sensor (INT 2 Kriwan make) 8 Oil service valve 9 Water-cooled cylinder covers Sea water resistant water-cooled cylinder covers 10 Connection piece suction and discharge valve in welded construction 11 Intermediate adapter for discharge line valve Special voltage and/or frequency (on request) 1) Not available HG7/ S Attention: Electric, respectively electronic components of the standard extent of delivery, from the accessories or that are obtained otherwise have to be handled and mounted in such a way that the corresponding regulations for the use of hydrocarbons are fulfilled Gb Subject to change without notice 27
28 Accessories Start unloader / Capacity regulator ESS Electronic Soft Start EFCe Electronic Frequency Control external ES Electronic Single hase 5 reparation for capacity regulator 6 Oil pressure differential sensor 7 Oil service valve Water-cooled cylinder covers Connection piece in welded construction Intermediate adapter for discharge line valve Gb Subject to change without notice
29 Service - Made by GEA Bock Worldwide, Up-to-Date, Comprehensive - GEA Bock on the Internet - roducts --Comprehensive product brochure --Data on all products --Dimensions and exploded views --Spare parts lists Sales network --Contact persons in over countries --Direct link to your trading partner Company --Current company information --Company film --Subsidiaries --History --References News --Company news --roduct news --Current dates Toolbocks - The Refrigeration App --ower Converter --Length Converter --ressure Converter --Converter Tube Diameter --Refrigerant Calculator --Location Finder --Error Analysis/Troubleshooter Wordbock - Translation Tool --Available as an app and --As an online version on Know-how --Error analysis tool --VA software --Comprehensive information Gb Subject to change without notice 29
30 Service - Made by GEA Bock After Sale Service GEA Bock offers you individual, personal consultation and assistance after the purchase as well. As a customer, GEA Bock always has competent contact people available to you for technical questions. Outside our business hours, you can reach us on our free hotline: from Monday to Saturday, 8:00 a.m. to 9:00 p.m Gb Subject to change without notice
31 Service - Made by GEA Bock uality by GEA Bock - The benchmark in cooling and air-conditioning The name GEA Bock stands worldwide for compressor technology with the highest level of quality. Certified quality from GEA Bock The goal of quality leadership in all product areas has always been at the centre of our company philosophy in our over 75-year history. Today, permanent optimisation of quality, not just on the product but in all areas, is the core of GEA Bock's company strategy. GEA Bock meets the requirements of DIN EN ISO 9001:2008, certified through DS, as well as numerous additional European and globally recognised standards. In addition, GEA ock maintains a system of internal company standards, which go well beyond public regulations in many points Gb Subject to change without notice 31
GEA Bock HC Compressors. Semi-hermetic Compressors for Hydrocarbons. engineering for a better world. GEA Refrigeration Technologies
GEA Bock HC Compressors Semi-hermetic Compressors for Hydrocarbons engineering for a better world GEA Refrigeration Technologies At a Glance Differences to a standard compressor Electronic motor protection
More informationGEA Bock 6 and 8 Cylinder Compressors HG76e and HG88e
GEA Bock 6 and 8 Cylinder Compressors HG76e and HG88e Semi-hermetic iston Compressors for large Refrigerating Capacities engineering for a better world GEA Refrigeration Technologies At a glance GEA Bock
More informationSemi-hermetic Bock Compressors. Single-stage and Two-stage Reciprocating Compressors HG (HA) engineering for a better world
Semi-hermetic Bock Compressors Single-stage and Two-stage Reciprocating Compressors HG (HA) engineering for a better world GEA Refrigeration Technologies In touch with our customers GEA Refrigeration Technologies:
More informationGEA Bock Compressors HG44e and HG56e. Semi-hermetic GEA Bock Compressors. engineering for a better world. GEA Refrigeration Technologies
GEA Bock Compressors HG44e and HG56e Semi-hermetic GEA Bock Compressors engineering for a better world GEA Refrigeration Technologies At a glance GEA Bock compressors HG44e and HG56e Our solutions are
More informationHG Series Aluminium Design
HG Series Aluminium Design Semi-hermetic compressors in aluminium design for mobile applications 1 At a glance Based on our compressors of the Pluscom series with their outstanding advantages and features,
More informationBock Compressors for Mobile Applications. Vehicle compressors for bus-, railway air-conditioning and transport refrigeration
Bock Compressors for Mobile Applications Vehicle compressors for bus-, railway air-conditioning and transport refrigeration engineering for a better world GEA Refrigeration Technologies In touch with our
More informationGEA Bock Open Type Compressors F. The full range of open type compressors and units. engineering for a better world. GEA Refrigeration Technologies
The full range of open type compressors and units engineering for a better world GEA Refrigeration Technologies In touch with our customers GEA Refrigeration Technologies: Your partner for low temperatures
More informationHGX6/ S Engine: V Y/YY -3-50Hz PW Refrigerant: R404A, R507
Performance data Application: Refrigeration & AC Refrigerant R404A, R507 Power supply 50 Hz, 400 V Supply frequency 50 Hz Evaporating temperature 5.0 C Evaporating pressure (abs.) 7.06 bar Condensing temperature
More informationGEA Bock HC Compressors. Semi-hermetic Compressors for Hydrocarbons
GEA Bock Compressors Semi-hermetic Compressors for Hydrocarbons 2 GEA COMPRESSORS Advanced competence, in touch with you In this brochure we present our current program of semi-hermetic GEA compressors
More informationBock Compressors for Mobile Applications. Vehicle compressors for bus-, railway air-conditioning and transport refrigeration
Bock Compressors for Mobile Applications Vehicle compressors for bus-, railway air-conditioning and transport refrigeration engineering for a better world GEA Refrigeration Technologies In touch with our
More informationSemi-hermetic GEA Compressors. Single- and two-stage reciprocating compressors (HG/HA)
Semi-hermetic GEA Compressors Single- and two-stage reciprocating compressors (HG/HA) 2 Introduction Advanced competence, in touch with you In this brochure we present our current program of single-stage
More informationGEA Bock ATEX Compressors for zone 1. Semi-hermetic Compressors in Explosion-risk Environments. Device category 2G according directive 94/9/EG
GEA Bock ATEX Compressors for zone Semi-hermetic Compressors in Explosion-risk Environments Device category 2G according directive 94/9/EG engineering for a better world GEA Refrigeration Technologies
More informationGEA Bock Plusbox. Plug & Play Units powered by GEA Bock Compressors. engineering for a better world. GEA Refrigeration Technologies
GEA Bock lusbox lug & lay Units powered by GEA Bock Compressors engineering for a better world GEA Refrigeration Technologies Bock lusbox Outdoor Condensing Units Flexible, efficient, reliable. GEA gives
More informationGEA Bock FK and HG compressors for mobile applications
GEA Bock FK and HG compressors for mobile applications For bus- and railway air-conditioning 2 GEA COMRESSORS GEA Your partner for busand railway air-conditioning Continuity through change GEA Group AG
More informationSemi-hermetic GEA Bock Compressors. Single-stage and Two-stage Reciprocating Compressors HG (HA) engineering for a better world
Semi-hermetic GEA Bock Compressors Single-stage and Two-stage Reciprocating Compressors HG (HA) engineering for a better world GEA Refrigeration Technologies In touch with our customers GEA Refrigeration
More informationBock Australia Pty Ltd Condensing Unit Catalogue
Bock Australia Pty Ltd Condensing Unit Catalogue The full range of Bock indoor and outdoor condensing units engineering for a better world GEA Refrigeration Technologies In touch with our customers GEA
More informationGEA Bock Software. VAP (online) for mobile applications NEW IN THIS VERSION
GEA Bock Software VA 11.4.0 (online) for mobile applications NEW IN THIS VERSION New compressor types 2 New compressor type: GEA Bock FKX40/755 K FKX40/755 K Expansion of proven FK40 model for bus and
More informationBock open type compressors F28. Extended F Series. engineering for a better world. GEA Refrigeration Technologies
Bock open type compressors F28 Extended F Series engineering for a better world GEA Refrigeration Technologies At a Glance Thermal protection thermostat at cylinder covers (Accessories) Integrated leak
More informationSemi-hermetic reciprocating compressors
v9 FCAT00.6-EN Product Selection Catalogue Version Hz Catalogue index Index - General information General information Range of models Special features Technical specifications Multifunctional device Kriwan
More informationPRODUCT INFORMATION. EFC / EFCe. EFC / EFCe. Extension of production programme Electronic Frequency Control systems
Extension of production programme Electronic Frequency Control systems 1 The systems Electronic Frequency Control Continuously variable speed control using frequency converter technology The EFC-System
More informationGEA Bock Software VAP 11 (Online) New in this version
GEA Bock Software VAP 11 (Online) New in this version June 2014 1 Overview New in this version VAP 11 (Online) New products/product features: New type size in FDK-series (open type compressor units): FDK18
More informationSemi Hermetic. Refrigeration Technologies RECIPROCATING COMPRESSORS. R134a, R404A, R507A, R407C, R22, R410A* R508b
A n I S O 9 0 0 : 0 0 0 O r g a n i z a t i o n Refrigeration Technologies Semi Hermetic RECIROCATING COMRESSORS R34a, R4A, R7A, R7C, R, R40A* R8b Approved by European standards ENVIRONMENT FRIENDLY LESS
More informationManeurop reciprocating compressors MT - MTZ - NTZ
MAKING MODERN LIVING POSSIBLE Quick reference Maneurop reciprocating compressors MT - MTZ - NTZ 60 Hz - R404A - R507A - R407C - R134a - R22 - R417A www.cc.danfoss.com Quick reference Dimensions Ø D ø
More informationTwo-stage semi-hermetic reciprocating compressors Application at low temperature
Two-stage semi-hermetic reciprocating compressors Application at low temperature v Product Selection Catalogue Version Hz / 0Hz Catalogue index General information Diagnose multifunctional device Special
More informationManeurop reciprocating compressors MT - MTZ - NTZ
Maneurop reciprocating compressors MT - MTZ - NTZ 60 Hz - R404A - R507 - R407A/C/F - R134a - R22 - R417A http://cc.danfoss.com Dimensions Ø D ø D ø D H1 H H1 H H1 H H H2 H2 H2 W D MT / MTZ / NTZ 1 cylinder
More information50Hz ZB76KCE-TFD R404A Dew Point
50Hz ZB76KCE-TFD R404A Dew Point 60 50 40 30 20 10-25 -20-15 -10-5 0 5 10 15 Minimum evaporating temp. with: 10K Suction Superheat 20 C Suction Gas Return Suction Return Temperature 20,0 C Evaporating
More informationVoltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]
Open condensing units with air condenser and semi-hermetic compressor Galvanized and painted in RAL7035 base Semi-hermetic compressor Air condenser unit with 4 poles fans 230/1 Vibration absorber on discharge
More informationCrankcase pressure regulator Type KVL
MAKING MODERN LIVING POSSIBLE Data sheet Crankcase pressure regulator KVL Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor
More informationMSC 110mm Series Vertical Medium Screw Compressors
MSC 110mm Series Vertical Medium Screw Compressors 10 110 TR (35 385kW) : 118 176 CFM : 65 115 HP Products that perform... By people who care INTRODUCTION Backed by over 40 years of experience, the Dunham-Bush
More informationCapacity regulators (hot gas bypass) PMC and CVC
MAKING MODERN LIVING POSSIBLE Technical brochure Capacity regulators (hot gas bypass) PMC and CVC The PMC and CVC is used for capacity regulation in refrigeration, freezing and air conditioning plant for
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationSelection & Application Guidelines Performer scroll compressors in parallel installation
Selection & Application Guidelines Performer scroll compressors in parallel installation R22 - R407C - R134a CONTENTS GENERAL OVERVIEW...p 4 Benefits... p 4 Scope... p 4 Design challenge... p 4 Oil equalisation...
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationProduct Data Sheet HKK70VSD Revision 1 (Variant Code E)
Product Data Sheet Revision 1 (Variant Code E) 1 Application Application Refrigerant Expansion Device Cooling Type LBP R600a Capillary Static To be used also in appliances with stop valve (technical consultation
More informationStainless steel - the strong solution
MAKING MODERN LIVING POSSIBLE Stainless steel - the strong solution TU and TC thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION TU / TC: superior by design and function The function
More informationThermostatic expansion valves Type TGE 10, TGE 20 and TGE 40
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40 TGE is a dedicated designed series of thermostatic expansion valves for all standard refrigerants including
More informationK and L Reciprocating Compressor Range
K and L Reciprocating Compressor Range Small 2-cylinder semi-hermetic reciprocating compressors for medium and low temperature refrigeration applications and transport refrigeration. Designed on the principle
More informationCrankcase pressure regulator Type KVL
Data sheet Crankcase pressure regulator KVL Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor against overload during start-up
More informationSection 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH
AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized
More informationXV7.2KX Variable Speed Drive Compressor R600a V 50/60Hz
XV7.2KX Variable Speed Drive Compressor R600a 220-240V 50/60Hz General Code number Electronic unit (attached) - XV-AEO/Freq. Inputs: Modbus, thermostat, frequency signal Electronic unit (detached) - XV-Frequency
More information50Hz ZBD45KCE-TFD R404A Dew Point
50Hz ZBD45KCE-TFD R404A Dew Point 60 50 40 30 20 10-25 -20-15 -10-5 0 5 10 Minimum evaporating temp. with: 25 C Suction Gas Return 10K Suction Superheat Suction Return Temperature 20,0 C Evaporating Temperature
More informationVTZ variable speed Reciprocating compressors
MAKING MODERN LIVING POSSIBLE Application guidelines VTZ variable speed Reciprocating compressors R404A, R507, R407C, R134a www.danfoss.com CONTENT VARIABLE SPEED COMPRESSORS... 4 Speed control...4 Advantages
More informationDanfoss scroll compressors SM / SY / SZ / SH / WSH
MAKING MODERN LIVING POSSIBLE Datasheets Danfoss scroll compressors SM / SY / SZ / SH / WSH FRCC.UD.130824.172326 www.danfoss.com/odsg Datasheet, technical data Performer scroll compressor, SH161-4 General
More informationZF Copeland Scroll Compressor Range for Low Temperature Refrigeration using R407A/F, R448A/R449A and R404A
ZF Copeland Scroll Compressor Range for Low Temperature Refrigeration using R7A/F, R448A/R449A and R4A Emerson Climate Technologies developed the ZF range to provide the best performance in low temperature.
More informationOptyma TM Slim Pack Just mount, braze and plug
MAKING MODERN LIVING POSSIBLE Catalogue Optyma TM Slim Pack Just mount, braze and plug R404A/R507 - R34a www.danfoss.com Content The new cost effective outdoor solution... 4 Features and cooling capacity...
More informationMT/MTZ 50 Hz R22 R407C R134a R404A / R507
Selection & Application guidelines RECIPROCATING COMPRESSORS MT/MTZ Hz R22 R47C R134a R44A / R7 1 CYLINDER 2 CYLINDERS 4 CYLINDERS 8 CYLINDERS Refrigeration and Air Conditioning Expect more from us DANFOSS
More informationInvoTech. YH series Scroll Compressors. Special Design For A /C and Chiller
InvoTech YH series Scroll Compressors Special Design For A /C and Chiller It is the outstanding engineering capability that builds the incomparable reliability InvoTech Scroll Technologies Co., Ltd. is
More information30% energy savings with Danfoss inverter scrolls accelerate ROI.
Danfoss compressors for comfort and precise cooling Air Conditioning with scroll and reciprocating technologies Over 30% energy savings with Danfoss inverter scrolls accelerate ROI. www.danfoss.com cc.danfoss.com
More informationCCMT - Electrically operated valves for transcritical and subcritical CO2
MAKING MODERN LIVING POSSIBLE Technical brochure - Electrically operated valves for transcritical and subcritical CO2 The is an electrically operated valve designed specifically for operation in CO 2 systems.
More informationRENISO TRITON SE/SEZ Synthetic refrigeration oils based on polyol esters (POE) for HFC/FC refrigerants
RENISO TRITON / Description The refrigeration oils of the RENISO TRITON / series are based on synthetic esters that were especially developed for use with chlorine-free, fluorinated hydrocarbons (HFC/FC).
More informationInverter scroll compressors VZH single and manifold
Application guidelines Inverter scroll compressors VZH088-117-170 single and manifold R410A http://cc.danfoss.com Content VZH088-117-170 - single compressors... 4 VZH088-117-170 - hybrid manifolding...
More informationGEA Screw Compressors. Screw compressors for industrial refrigeration and air conditioning
GEA Screw Compressors Screw compressors for industrial refrigeration and air conditioning 2 Top quality based on proven development Whether it s in the food industry, chemical industry, in offices or in
More informationCWP-CO / CWP-RC / CWP-HP 02 to 35
Water Cooled Water Chillers Cooling Only, Condenserless and Heat Pump Versions - / - / - 02 to 35 8 to 136 9 to 164 Technical Brochure TM -N.4GB Date : March 2006 Supersedes : TM -N.3GB/05.04 Technical
More informationTD35 VS - TD50 VS Compressor for R134a 12/24V DC Technical specifications
TD35 S - TD50 S Compressor for R134a 12/24 DC Technical specifications Thank you for choosing the TD35 S and TD50 S R134a 12/24 DC compressor. Please read this manual thoroughly before beginning operation.
More informationCS Series Condensing Units
BITZER CS CONDENSING UNITS CS Series Condensing Units Standard Features: Bitzer Octagon Semi hermetic Compressor Fully wired Electrical Panel Three Phase Isolator Condenser with dedicated Sub-Cooling Circuit
More informationLow-Voltage Motors N-compact Standardline Operation on supply system
Low-Voltage Motors N-compact Standardline Operation on supply system 2 2/2 Overview 2/2 Benefits 2/2 Technical specifications 2/2 Selection and Ordering Data 2/ Options 2/ Dimensional drawings 2/4 More
More informationSemi-Hermetic Condensing Units KL
Semi-Hermetic Condensing Units KL Copeland air-cooled indoor condensing units for medium temperature and low temperature applications. Long-term engineering and manufacturing experience has led to these
More informationMAKING MODERN LIVING POSSIBLE CO₂. A green Compressor. clean thinking REFRIGERATION & AIR CONDITIONING DIVISION
MAKING MODERN LIVING POSSIBLE CO₂ A green Compressor clean thinking REFRIGERATION & AIR CONDITIONING DIVISION CO₂ Compressor tailored for light commercial applications and heat pumps Our ultra-efficient
More informationCrankcase pressure regulator Type KVL
Data sheet Crankcase KVL KVL crankcase are used to protect the compressor motor against overload experienced during startup after long off periods or just after defrost periods. They are installed in the
More informationRENISO K. Special naphthenic refrigeration oils. Description. Advantages. Application. Specifications
Description RENISO K refrigeration oils are based on highly refined, naphthenic selective raffinates that have been dewaxed especially for use at low temperatures. Their degree of refinement ensures that
More informationSLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw
Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features
More informationDanfoss Commercial Compressors Towards more eco-friendly commercial refrigeration systems
MAKING MODERN LIVING POSSIBLE Technical product news Towards more eco-friendly commercial refrigeration systems Using R407A, R407F as drop-in of R404A systems Table 1 The refrigeration industry has made
More informationDanfoss scroll compressors SH series
Quick reference anfoss scroll compressors S series R410A - 60 z http://cc.danfoss.com Product range single compressors Ø 2 1 S090-105-120-140-161 Ø 2 2 1 2 Ø S184 Ø 1 2 S090 243 482 235 451 S105 243 540
More informationHot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)
MAKING MODERN LIVING POSSIBLE Data sheet Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) A CPCE hot gas bypass regulator is used to adapt compressor capacity to actual evaporator
More informationr410a // hermetic VSD Operation 60 Hz // ESP-133-2
r410a // hermetic Scroll compressors orbit Series: Variable Speed Drive VSD Operation 60 Hz // ESP-133-2 ORBIT for variable speed drive (VSD) While the scroll compressors of the ORBIT series are characterized
More informationInvoTech. YH series Scroll Compressors. Special Design For A /C and Chiller
InvoTech YH series Scroll Compressors Special Design For A /C and Chiller It is the outstanding engineering capability that builds the incomparable reliability InvoTech Scroll Technologies Co., Ltd. is
More informationRefrigeration Applications
34 Refrigeration Applications Refrigeration Applications Emerson Climate Technologies offers a wide range of solutions for commercial refrigeration applications. With its long-lasting expertise in semi-
More informationThermostatic Expansion Valve
STANDARD Thermostatic Expansion Valve RFGD series thermostatic expansion valves are used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant s superheat at the outlet
More informationTecumseh Semi Hermetic Condensing Units
actrol.com.au Tecumseh Semi Hermetic Condensing Units Reciprocating April 2014 global brands - local service HTA EVO Condensing Units Tecumseh Semi Hermetic Reciprocating Standard Features The new range
More informationThermostatic expansion valves type TGE 10, TGE 20 and TGE 40
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves TGE 0, TGE 20 and TGE 40 TGE is a dedicated designed series of thermostatic expansion valves for all standard refrigerants.
More informationThermostatic expansion valves type TGE 10, TGE 20 and TGE 40
MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves TGE 0, TGE 20 and TGE 40 TGE is a dedicated designed series of thermostatic expansion valves for all standard refrigerants.
More informationCONTINUOUS CAPACITY CONTROL MODELS
This series of air-cooled water chillers up to 400HP has been developed for various requirements of air conditioning systems and industrial chilled water systems, where these equipments are operated under
More informationCHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC)
CHILLER START UP PROCEDURE FORM DOC. N 061103 (DOC.N 071103 BELOW TO BE RETURN TO AERMEC) 1. Preliminary Operation WARNING: The following operation must be done without the power supply (unit with the
More informationInvoTech. YH series Scroll Compressors. Special Design For A /C and Chiller
InvoTech YH series Scroll Compressors Special Design For A /C and Chiller It is the outstanding engineering capability that builds the incomparable reliability Scroll Compressors With Dual-Compliance For
More informationSEMI-HERMETIC RECIPROCATING COMPRESSOR MULTIPLE COMPRESSORS UNIT WITH LEADING INVERTER COMPRESSOR ORIGINAL MANUFACTURED EQUIPMENT
SEMI-HERMETIC RECIPROCATING COMPRESSOR MULTIPLE COMPRESSORS UNIT WITH LEADING INVERTER COMPRESSOR ORIGINAL MANUFACTURED EQUIPMENT PRODUCTS SPECIFICATIONS In a world where energy efficiency and sustainability
More informationCopeland Screw Compressors Semi-Hermetic Compact Operating Instructions
Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions SCH2 & SCA2 High Temperature Compressors 35-240 Horsepower 1. Introduction This series of semi-hermetic compact screw compressors
More informationProgress all along the line
semi-hermetic ECOLINE reciprocating compressors Progress all along the line 60 Hz // KP-095-2 US The ECOLINE Series HIGHLY EFFICIENT WITH HIGH PERFORMANCE The ECOLINE series is the creative further development
More informationR134a R134a R13. 4a R134a R134a R134
Product Information Compressors for Refrigerant R134a 12-24 olt Direct Current Compressors a R R134a R 34a R134a R1 R134a R134a R13 4a R134a R134a R134 R134a R134a R134a R134a 34a R134a R134a R134a R134a
More information00% Text in bar Equipis atet nit ulput pratum zzril delent lam, con ut in vercing ea adit. Optyma Plus TM New Generation Plug and play solution
MAKING MODERN LIVING POSSIBLE Catalogue Optyma Plus TM New Generation Plug and play solution R404A/R507, R134a 00% Text in bar Equipis atet nit ulput pratum zzril delent lam, con ut in vercing ea adit.
More informationYH Series Scroll Compressors With Dual-Compliance For A/C and Chiller
Scroll Compressors With Dual-Compliance For A/C and Chiller Specific Design For A/C and Chiller, Not Only The Scroll Set But Also The Unit, Precise Product-Definition Based On Customer's Need Both Build-in
More informationSelection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING
Selection & Application guidelines Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING www.danfoss.com 50 HZ BLUESTAR PRODUCT PROGRAMME....... p 3 Product
More informationLSC Series. Open Drive Large Screw Compressors. Fifteen Displacements. 50-2,500 TR (176-8,785 kw) 278-3,336 CFM 100-2,200 HP
Open Drive Large Screw Compressors Fifteen Displacements 50-2,500 TR (176-8,785 kw) 278-3,336 CFM 100-2,200 HP Designed for Refrigeration, Air- Conditioning, and Process Applications Field Serviceable
More informationDanfoss scroll compressors SM SY SZ
Quick reference Danfoss scroll compressors SM SY SZ R407C - R134a - R22-60 z http://danfoss.us.com/ Product range single compressors 0 D Ø D Ø D ØD 2 2 2 2 1 1 1 1 2 1 ØD 200-230V/3~/60z Motor voltage
More informationr410a // hermetic orbit 6: Tandem // Trio Expanded Capability 50 Hz // ESP-121-2
r410a // hermetic Scroll compressors r410a // hermetische scrollverdichter r410a // Compresseurs hermétiques à scroll orbit 6: Tandem // Trio Expanded Capability 50 Hz // ESP-121-2 ORBIT 6 compound compressor
More informationVLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw
Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension
More informationDanfoss scroll compressors SM SY SZ
Quick reference Danfoss scroll compressors SM SY SZ R407C - R134a - R22-60 z http://cc.danfoss.com Product range single compressors Ø D Ø D ØD 0 D 2 2 2 2 1 1 1 1 D 1 2 S084-090-100 254 508 142 465 S110-120
More informationFRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH
FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TAbLE Of CONTENTs NOMENCLATURE............................. 3 features.................................... 4 KV series features.........................
More information00% Optyma Plus TM New Generation Plug and play solution. Catalogue. R404A/R507, R134a MAKING MODERN LIVING POSSIBLE.
MAKING MODERN LIVING POSSIBLE Catalogue Optyma Plus TM New Generation Plug and play solution R404A/R507, R134a 00% Text in bar Equipis atet nit ulput pratum zzril delent lam, con ut in vercing ea adit.
More informationVariable Speed DC Compressors and Condensing Units
Variable Speed DC Compressors and Condensing Units Variable Speed DC Compressors and Condensing Units Tecumseh offers a wide range of Masterflux DC powered variable speed compressors and condensing units
More informationInvoTech. Scroll Compressor. Product Manual. It is the outstanding engineering capability that builds the incomparable reliability
InvoTech Scroll Compressor Product Manual It is the outstanding engineering capability that builds the incomparable reliability InvoTech Scroll Technologies Co., Ltd. is a high-tech company. Our company
More informationParallel Rack Systems R404A
Parallel Rack Systems R404A Capacity RANGE R404A-MT R404A-LT 41kW to 445kW 16kW to 127kW s s 1 Altitude Racks This brochure contains examples of our standard range of medium and low temperature compressor
More informationSemi-Hermetic Compressor Receiver Packages
Semi-Hermetic Compressor Receiver Packages Compressor on receiver package for remote condenser installation Semi-Hermetic Compressor Receiver Packages 1 R4A MT Data Sheet Altitude CR-10MZ CR-15MZ CR-MZ
More informationSolenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and servo operated versions, they can be applied in liquid, suction, and hot
More informationDanfoss scroll compressors SH series
anfoss scroll compressors S series R410A - 60 z http://danfoss.us.com/ Product range single compressors 2 1 S090-105-120-140-161 2 1 S184 Motor voltage code Code 3 Code 4 Code 7 Code 9 Nominal voltage
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationScrew Compressors for Commercial Air Conditioning and Refrigeration
Screw Compressors for Commercial Air Conditioning and Refrigeration SHL - Low Temperature SHM - Medium Temperature SCH - High Temperature SDM - Medium Temperature Open Drive SDL - Low Temperature Open
More information00% Optyma Plus TM New Generation Plug and play solution. Catalogue. R404A/R507, R134a MAKING MODERN LIVING POSSIBLE.
MAKING MODERN LIVING POSSIBLE Catalogue Optyma Plus TM New Generation Plug and play solution R404A/R507, R134a 00% Text in bar Equipis atet nit ulput pratum zzril delent lam, con ut in vercing ea adit.
More informationr410a // hermetic orbit Series: Tandem // Trio Improved Performance 60 Hz // ESP-136-5
r4a // hermetic Scroll compressors orbit Series: Tandem // Trio Improved Performance 60 Hz // ESP-136-5 ORBIT compound compressor assemblies (GSD series) ORBIT Tandem and Trio scroll compressor assemblies
More informationWater-Cooled Condensing Units. Shell & Tube Condenser Low Operating Cost Durable Construction Built in Receiver
Water-Cooled Condensing Units Shell & Tube Condenser Low Operating Cost Durable Construction Built in Receiver Water-Cooled Condensing Units General Information Units are built with semi-hermetic reciprocating
More informationChiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.
Chiller SWS/SWR 1602 to 4802 Water Cooled Chillers Only and Condenserless Versions Engineering Data Manual 272 to 1118 kw Specifications General The SWS water cooled screw chillers are equipped with high
More information