Modular Variable Speed Air Handlers
|
|
- Mervyn Reynolds
- 6 years ago
- Views:
Transcription
1 Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 2 1/2-5 Ton 2TEE3C31A1000A 2TEE3C37A1000A 2TEE3C40A1000A 2TEE3C49A1000A 2TEE3C65A1000A 4TEE3C31A1000A 4TEE3C37A1000A 4TEE3C40A1000A 4TEE3C49A1000A 4TEE3C65A1000A Trane 2009 PU. NO
2 Features and enefits Ships vertical - converts to horizontal by laying unit on side. Six-way convertibility horizontal (left & right), front & rear access; upflow, downflow Electrical, refrigerant, condensate & blower access convertible to either side Compact 21" depth for easy installation Variable speed ECM motor Direct drive blower Comfort- enhanced dehumidification cycle Soft Start - On cycle fan speed is increased gradually to reduce sound and drafts Corrosion resistant galvanized metal with attractive finish Non-bleed Expansion valve Check valve for heat pump application Internally enhanced finned coil tubing External brazed refrigerant connections 200/230 volt primary & 24 volt secondary transformer Low voltage terminal board Uses 1400 series heaters Access to heater circuit breakers Polarized plugs for making motor and transformer electrical connections from air handler control box to electric heaters Primary and secondary drain connections Easy Air-Tite TM access to coils uilt-in indoor fan delay function for increased efficiency 2/4TEE3C31 airflow selectable for 1-1/2 3 ton O.D. unit 2/4TEE3C37, 2/4TEE3C40 airflow selectable for 2 3-1/2 ton O.D. unit 2/4TEE3C49 airflow selectable for 3 5 ton O.D. unit 2/4TEE3C65 airflow selectable for 3 5 ton O.D. unit Energy-saving continuous fan Enhanced cooling/heating control ComfortLink TM II 3-wire connectivity or 24 volt connection. Optional Equipment OPTIONAL EQUIPMENT FO AI HANDLES (Check mark [ ] indicates accessories included). Plenum - Pedestal (2/4TEE3C37, 40, 49, 65)... TAYPLNM100 [ ] Sub-base For Downflow (2/4TEE3C31)... TAYASE101 [ ] Sub-base For Downflow (2/4TEE3C37)... TAYASE100 [ ] Sub-base For Downflow (2/4TEE3C40, 49, 65)... TAYASE102 [ ] Evaporator Defrost Control Kit - Cooling Units (Low Ambient Cooling)...A8X079 [ ] Evaporator Defrost Control Kit - Heat Pumps (Low Ambient Cooling)...A8X084 [ ] Knockout cover plate (2/4TEE3C31, 37, 40, 49, 65)... AY99X123 [ ] Humidistat... AYSTAT253 [ ] Plenum For Upflow Non-Ducted Applications (2/4TEE3C31, 37, 40, 49, 65)... AYPLNM120 [ ] 2009 Trane 2 Pub. No
3 Contents Features and enefits 2 Optional Equipment 2 Air-Tite Features and enefits 4 General Data 5 2TEE3C31A1000A 4TEE3C31A1000A 5 2TEE3C37A1000A 4TEE3C37A1000A 5 2TEE3C40A1000A 4TEE3C40A1000A 5 2TEE3C49A1000A 4TEE3C49A1000A 5 2TEE3C65A1000A 4TEE3C65A1000A 5 Performance Data 6 Electrical Data 11 Mounting 15 Wiring Diagram 16 Field Wiring 17 Convertibility 20 Dimensions 21 Outline Drawing 22 Mechanical Specification Options 24 Pub. No
4 Air-Tite Features and enefits 1 New Duct Flange Allows flush fit for 3 /4", 1" or 1 1 /2" duct insulation. 2 Liner/Flange Seal Exclusive Duct Flange Thermal reak/seal and double wall construction to reduce cabinet loss and sweating. 3 1" Foil Faced Insulation Thicker foil faced insulation for reduced cabinet loss, sweating and lower power bills. 4 Enclosed Control ox Totally enclosed control box with transformer inside to improve component life, unit durability and reliability. 5 Corrosion esistant Screws Exclusive Weatherguard coated screws to maintain the quality appearance of the unit for the life of the product. 6 Coupling Panel Insulation Exclusive No urn refrigerant coupling panel with thicker insulation for reduced heat loss. 7 Filter Door Seal Improved door seal for reduced air infiltration, heat transfer, and lower power bills. 8 Insulation on Center ar Exclusive center bar insulation for reduced cabinet loss, sweating and lower power bills. 9 Door Gasket Exclusive formed gasket (similar to a car door gasket) to reduce air infiltration and heat transfer and lower power bills. 0 Air-Tite Circuit reaker Door Easy access to breakers with positive air seal. 4 Pub. No
5 General Data MODEL ATED VOLTS/PH/HZ. ATINGS 1 INDOO COIL Type ows F.P.I. Face Area (sq. ft.) Tube Size (in.) efrigerant Control Drain Conn. Size (in.) 2 INDOO FAN Type Diameter-Width (In.) No. Used Drive - No. Speeds CFM vs. in. w.g. 1 No. Motors H.P. Motor Speed.P.M. Volts/Ph/Hz F.L. Amps - L.. Amps FILTE 3 All Applications? Type Max. Indoor elative Humidity 4 EFIGEANT ef. Line Connections Conn. Size in. Gas Conn. Size in. Liq. DIMENSIONS Crated (In.) Uncrated WEIGHT 2TEE3C31A1000A 4TEE3C31A1000A /1/60 See O.D. Specifications Plate Fin /8 - Copper TXV - Nonleed 3/4 NPT Centrifugal 10 x 8 1 Direct - Serial ECM See Fan Performance Table 1 1/2 Variable /1/ Yes Low Velocity 1 x 20 x 20 65% A razed razed 3/4 3/4 5/16 5/16 H x W x D 44-1/2 x 24 x 23-1/2 43 x 21-1/2 x / 118 2TEE3C37A1000A 4TEE3C37A1000A /1/60 See O.D. Specifications Plate Fin /8 - Copper TXV - Nonleed 3/4 NPT Centrifugal 10 x 10 1 Direct - Serial ECM See Fan Performance Table 1 1/2 V ariable /1/ Yes Low Velocity 1 x 20 x 20 65% A razed razed 7/8 3/4 3/8 3/8 H x W x D 46-1/2 x 26 x 23-1/2 45 x 23-1/2 x / 127 2TEE3C40A1000A 4TEE3C40A1000A /1/60 See O.D. Specifications Plate Fin /8 - Copper TXV - Nonleed 3/4 NPT Centrifugal 10 x 10 1 Direct - Serial ECM See Fan Performance Table 1 1/2 Variable /1/ Yes Low Velocity 1 x 20 x 25 65% A razed razed 7/8 3/4 3/8 3/8 H x W x D 53-1/4 x 28-1/2 x 23-1/2 51-3/4 x 26 x / 155 MODEL ATED VOLTS/PH/HZ. ATINGS 1 INDOO COIL Type ows F.P.I. Face Area (sq. ft.) Tube Size (in.) efrigerant Control Drain Conn. Size (in.) 2 INDOO FAN Type Diameter-Width (In.) No. Used Drive - No. Speeds CFM vs. in. w.g. 1 No. Motors H.P. Motor Speed.P.M. Volts/Ph/Hz F.L. Amps - L.. Amps FILTE 3 All Applications? Type Max. Indoor elative Humidity 4 EFIGEANT ef. Line Connections Conn. Size in. Gas Conn. Size in. Liq. DIMENSIONS Crated (In.) Uncrated WEIGHT 2TEE3C49A1000A 4TEE3C49A1000A /1/60 See O.D. Specifications Plate Fin /8 - Copper TXV - Nonleed 3/4 NPT Centrifugal 10 x 10 1 Direct - Serial ECM See Fan Performance Table 1 3/4 Variable /1/ Yes Low Velocity 1 x 20 x 25 65% A razed razed 1-1/8 7/8 3/8 3/8 H x W x D 59-1/2 x 28-1/2 x 23-1/2 57-7/8 x 26 x /173 2TEE3C65A1000A 4TEE3C65A1000A /1/60 See O.D. Specifications Plate Fin /8 - Copper TXV - Nonleed 3/4 NPT Centrifugal 10 x 10 1 Direct - Serial ECM See Fan Performance Table 1 1 Variable /1/ Yes Low Velocity 1 x 20 x 25 65% A razed razed 1-1/8 7/8 3/8 3/8 H x W x D 63-1/4 x 28-1/2 x 23-1/2 62-3/4 x 26 x / These Air Handlers are A..I. certified with various Split System Air Conditioners and Heat Pumps (AI STANDAD 210/240). efer to the Split System Outdoor Unit Product Data Guides for performance data. 2 3/4" Male Plastic Pipe (ef.: ASTM ) 3 If a remote filter is added, it can not be within 6 inches of the air cleaner COLLECTION CELL. 4 The FIELD CHAGE may require more frequent cleaning in homes with high indoor relative humidity (greater than 65% H). Consult your service professional about cleaning intervals. Pub. No
6 Performance Data 2/4TEE3C31A AIFLOW PEFOMANCE TALE Performance 2/4TEE3C31A1: with Wet coil, No Heaters, Filter Outdoor Settings EXTENAL STATIC PESSUE (in.w.g.) Unit Size Name CFM/ton Power Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Demand is OD size (tons) * Speed (cfm/ton) NOTES: COMM SYS mode will auto-detect OD size, with default speed 400cfm/ton & 1.5 minute off-delay At continuous fan setting: values are approximately 50% of listed values. 6 Pub. No
7 Performance Data 2/4TEE3C37A AIFLOW PEFOMANCE TALE Performance 2/4TEE3C37A1: with Wet coil, No Heaters, Filter Outdoor Settings EXTENAL STATIC PESSUE (in.w.g.) Unit Size Name CFM/ton Power Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Demand is OD size (tons) * Speed (cfm/ton) NOTES: COMM SYS mode will auto-detect OD size, with default speed 400cfm/ton & 1.5 minute off-delay At continuous fan setting: values are approximately 50% of listed values. Pub. No
8 Performance Data 2/4TEE3C40A AIFLOW PEFOMANCE TALE Performance 2/4TEE3C40A1: with Wet coil, No Heaters, Filter Outdoor Settings EXTENAL STATIC PESSUE (in.w.g.) Unit Size Name CFM/ton Power Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Demand is OD size (tons) * Speed (cfm/ton) NOTES: COMM SYS mode will auto-detect OD size, with default speed 400cfm/ton & 1.5 minute off-delay At continuous fan setting: values are approximately 50% of listed values. 8 Pub. No
9 Performance Data 2/4TEE3C49A AIFLOW PEFOMANCE TALE Performance 2/4TEE3C49A1: with Wet coil, No Heaters, Filter Outdoor Settings EXTENAL STATIC PESSUE (in.w.g.) Unit Size Name CFM/ton Power Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Demand is OD size (tons) * Speed (cfm/ton) NOTES: COMM SYS mode will auto-detect OD size, with default speed 400cfm/ton & 1.5 minute off-delay At continuous fan setting: values are approximately 50% of listed values. Pub. No
10 Performance Data 2/4TEE3C65A AIFLOW PEFOMANCE TALE Performance 2/4TEE3C65A1: with Wet coil, No Heaters, Filter Outdoor Settings EXTENAL STATIC PESSUE (in.w.g.) Unit Size Name CFM/ton Power Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Low 290 CFM Watts Med-Lo 350 CFM Watts tons Med-Hi 400 CFM Watts High 450 CFM Watts Demand is OD size (tons) * Speed (cfm/ton) NOTES: COMM SYS mode will auto-detect OD size, with default speed 400cfm/ton & 1.5 minute off-delay At continuous fan setting: values are approximately 50% of listed values. 10 Pub. No
11 Electrical Data NOTES: *** = 000, K or PDC = pigtails, K = contains circuit breakers & PDC = contains pull disconnect. IMPOTANT: Any power supply and / or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical codes MIN LOWE SPEED VOLT MT AMPS HEATE AMPS MCA MOP 2/4TEE3C AYHT1405***C AYHT1408***C AYHT1410***C AYHT1415 KC circuit 2 AYHT1415 KC with single circuit power source kit AYSPEK140 AYHT C AYHT C AYHT1419 KC circuit 2 WITH OUT HEAT PUMP CAPACITY WITH TOTAL HEAT HEATE PUMP KW TUH AYHT1419 KC with single circuit power source kit AYSPEK (+) - For Upflow position without heat pump, minimum setting is 1130 NOTES: *** = 000, K or PDC = pigtails, K = contains circuit breakers & PDC = contains pull disconnect. IMPOTANT: Any power supply and / or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical codes MIN LOWE SPEED VOLT MT AMPS HEATE AMPS MCA MOP 2/4TEE3C AYHT1405***C AYHT1408***C AYHT1410***C AYHT1415 KC circuit 2 AYHT1415 KC with single circuit power source kit AYSPEK140 AYHT C AYHT C AYHT1419 KC circuit 2 WITH OUT HEAT PUMP CAPACITY WITH TOTAL HEAT HEATE PUMP KW TUH AYHT1419 KC with single circuit power source kit AYSPEK (+ ) - For horizontal right and and downflow position, minimum speed for heat pump applications is 1100 CFM (++ ) - For horizontal right and and downflow position, minimum speed without heat pump applications is 1100 CFM (+++ ) - Downflow configuration is not rated at 240V for the 1410 and not rated for 208 or 240 for the 1419 Pub. No
12 Electrical Data NOTES: *** = 000, K or PDC = pigtails, K = contains circuit breakers & PDC = contains pull disconnect. IMPOTANT: Any power supply and / or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical codes MIN LOWE SPEED AYHT1419 KC with single circuit power source kit AYSPEK140 VOLT MT AMPS HEATE AMPS MCA MOP 2/4TEE3C AYHT1405***C AYHT1408***C AYHT1410***C AYHT1415 KC circuit 2 AYHT1415 KC with single circuit power source kit AYSPEK140 AYHT C AYHT C AYHT1419 KC circuit 2 AYHT1425 KC circuit 2 WITH OUT HEAT PUMP CAPACITY WITH TOTAL HEAT HEATE PUMP KW TUH circuit 3 (+ ) - For horizontal right and downflow position, minimum speed for heat pump applications is 1100 CFM NOTES: *** = 000, K or PDC = pigtails, K = contains circuit breakers & PDC = contains pull disconnect. IMPOTANT: Any power supply and / or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical codes MIN LOWE SPEED VOLT MT AMPS HEATE AMPS MCA MOP 2/4TEE3C AYHT1405***C AYHT1408***C AYHT1410***C AYHT1415 KC circuit 2 AYHT1415 KC with single circuit power source kit AYSPEK140 AYHT C AYHT C AYHT1419 KC circuit 2 AYHT1419 KC with single circuit power source kit AYSPEK140 AYHT1425KC circuit 2 circuit 3 WITH OUT HEAT PUMP CAPACITY WITH TOTAL HEAT HEATE PUMP KW TUH Pub. No
13 Electrical Data NOTES: *** = 000, K or PDC = pigtails, K = contains circuit breakers & PDC = contains pull disconnect. IMPOTANT: Any power supply and / or combination power supply, circuit or circuits must be wired and protected in accordance with local Electrical codes MIN LOWE SPEED VOLT MT AMPS HEATE AMPS MCA MOP 2/4TEE3C AYHT1415 KC circuit 2 AYHT1415 KC with single circuit power source kit AYSPEK140 AYHT1419 KC circuit 2 AYHT1419 KC with single circuit power source kit AYSPEK140 AYHT1425 KC AYHT1405***C AYHT1408***C AYHT1410***C AYHT C AYHT C circuit 2 circuit 3 (+) - For upflow applications only, minimum speed is 1500 for HP off and 1800 for HP on. WITH OUT HEAT PUMP CAPACITY WITH TOTAL HEAT HEATE PUMP KW TUH Pub. No
14 Performance Data DISTANCE FOM ELLY AND TO SHAFT FACE OF MOTO FO MINIMUM VIATION LOWE HOUSING MODEL "A" INCHES WHEEL ELLY AND A MOTO A is determined per chart Wheel is centered in lower Housing 2/4TEE3C31A 1-1/8 2/4TEE3C37A 1-1/8 2/4TEE3C40A 1-1/8 2/4TEE3C49A 1-1/2 2/4TEE3C65A 2-1/8 FO FACTOY OEM MOTOS 14 Pub. No
15 Mounting AI HANDLE SUASE FLOO OPENING - SIZE MODEL NO. A TAYASE / /16 TAYASE / /16 TAYASE / /16 Pub. No
16 Wiring Diagram WIING DIAGAM FO VAIALE SPEED AI HANDLES 16 Pub. No
17 Field Wiring 2/4TEE3C31, 37, 40, 49 & 65A AI HANDLES WITH COMMUNICATING COMFOT CONTOL & COMMUNICATING OUTDOO UNIT Communicating Comfort Control Communicating Air Handler Communicating Outdoor Unit K K W3 W3 W2 W2 W1 W1 G G D D D O O NOTE: See Wiring Diagrams in Service Facts for complete wiring information. 2/4TEE3C31, 37, 40, 49 & 65A AI HANDLES WITH COMMUNICATING COMFOT CONTOL, 24V SINGLE STAGE COOLING Communicating Comfort Control Communicating Air Handler 24V Outdoor Unit 1-stage AC only K W3 W2 W1 G D D O NOTE: See Wiring Diagrams in Service Facts for complete wiring information. Pub. No
18 Field Wiring 2/4TEE3C31, 37, 40, 49 & 65A AI HANDLES WITH 24V COMFOT CONTOL, 24V SINGLE STAGE COOLING 24V Comfort Control 24V Air Handler 24V Outdoor Unit 1-stage AC only K K W3 W3 W2 W2 W1 W1 G G D O NOTE: See Wiring Diagrams in Service Facts for complete wiring information. 2/4TEE3C31, 37, 40, 49 & 65A AI HANDLES WITH 24V COMFOT CONTOL, 24V 2-STAGE O 2-STEP* COOLING 24V Comfort Control 24V Air Handler 24V Outdoor Unit 2-stage O 2-step* AC K K W3 W3 W2 W2 W1 W1 G G D *NOTE: See User Interface 24V Mode Setup Menu for 1st Stage CFM Options. 2-Stage = 50-60% 2-Step = 65-80% O NOTE: See Wiring Diagrams in Service Facts for complete wiring information. 18 Pub. No
19 Field Wiring 2/4TEE3C31, 37, 40, 49 & 65A AI HANDLES WITH 24V COMFOT CONTOL, 24V 1-STAGE HEAT PUMP 24V Comfort Control 24V Air Handler 24V Outdoor Unit 1-stage Heat Pump K K W3 W3 W2 W2 W1 W1 X2 G G D O O O NOTE: See Wiring Diagrams in Service Facts for complete wiring information. 2/4TEE3C31, 37, 40, 49 & 65A AI HANDLES WITH 24V COMFOT CONTOL, 24V 2-STAGE O 2-STEP* HEAT PUMP 24V Comfort Control 24V Air Handler 24V Outdoor Unit 2-stage O 2-step* HP K K W3 W3 W2 W2 W1 W1 X2 G G D *NOTE: See User Interface 24V Mode Setup Menu for 1st Stage CFM Options. 2-Stage = 50-60% 2-Step = 65-80% O O O NOTE: See Wiring Diagrams in Service Facts for complete wiring information. Pub. No
20 2/4TEE3C31 Through 65 Convertibility SIX (6) WAY CONVETIILITY One Unit - 4 Applications (Conversions 1-4) Easy Conversion to Opposite side Access (Conversions 5 & 6) Horizontal ight (as shipped) efrigerant Connections 1 Unit is shipped as Horizontal right Primary Condensate Horizontal Drain pan Coil Supports Vertical Upflow (as shipped) One-step Conversion Stand unit on end 2 Pull coil out and rotate the coil 180 Horizontal Left otate Coil 3 Slide coil back in on supports and roll unit 180 (so primary condensate is down) Vertical Downflow One-step Conversion from Horizontal left 4 Note connections and access are now on back side of unit 6 CONVESION APPLICATIONS 1. Horizontal ight - (Front Access) 2. Vertical Upflow 3. Horizontal Left - (Front Access) 4. Vertical Downflow 5. Horizontal ight - (ear Access) 6. Horizontal Left - (ear Access) 20 Pub. No
21 Dimensions 2/4TEE3C31, 37, 40, 49 & 65A1000A AI HANDLES DIMENSIONAL DATA 2/4TEE3C 65A is a two piece cabinet Model No. H W 2/4TEE3C31A1000A /4TEE3C37A1000A /4TEE3C40A1000A /4TEE3C49A1000A /4TEE3C65A1000A Pub. No
22 Outline Drawings OUTLINE DAWING FO 2/4TEE3C31, 37, 40, 49, 65A Printed from Dwg. D ev Pub. No
23 Mechanical Specification Options Features and General Information These blower coil units are completely factory assembled including coil, condensate drain pan, fan, motor, and controls in an insulated casing that can be applied in horizontal or vertical configuration. This new line of 2/4TEE3C air handlers provides exclusive compact size combined with 6-way convertibility in sizes up to 5 ton. The unit ships in the vertical upflow configuration and converts to righthand horizontal configuration just by laying the unit on its side. No tools required. Simple coil rotation provides downflow and horizontal left applications. Comfort Control Comfortlink II TM Communicating air handler design offers 3-wire connectivity for installation ease. Assures the entire heating and air conditioning system is set up in the proper modes to optimize the engineered performance of the matched system installed. Casing These models have a rugged galvanized sheet metal and steel frame construction. The casing is painted with an enamel finish. The casing is insulated and provides knockouts for electrical power and control wiring. efrigerant Circuits The 2/4TEE3C units have a single refrigerant circuit. The refrigerant circuit is controlled by a factory installed nonbleed thermal expansion valve (TXV). Coil Aluminum fin surface is mechanically bonded to 3/8-inch OD copper tubing. Coils are factory pressure and leak tested. Fan The blower housing is forward curved, dynamically balanced with a variable speed direct drive fan motor. The variable speed ECM fan motor is permanently lubricated. Controls Low voltage terminal board, fan contactor, and plug-in module for accessory electric heat control is included. 2/4TEE3C models also have a check valve. Electric Heaters Heaters for the 2/4TEE3C air handlers are available in a wide range of capacities and voltages with various staging options, and plug-in control wiring. Heaters fit inside the internal compartment. Pub. No
24 09/09 Trane 6200 Troup Highway Tyler, TX SinceTrane has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.
Modular Variable Speed Air Handlers
Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A
More informationProduct Data. Convertible Air Handlers 1 1/2 5 Ton B-EN. August 2015
Product Data Convertible Air Handlers 1 1/2 5 Ton TEM6A0B24H21S TEM6A0B30H21S TEM6A0C36H31S TEM6A0C42H41S TEM6A0D48H41S TEM6A0D60H51S The TEM6 series air handler is designed for installation in a closet,
More informationProduct Data. Convertible Air Handlers 1 1/2 5 Ton D-EN. September 2016
Product Data Convertible Air Handlers 1 1/2 5 Ton TEM6A0B24H21S TEM6A0B30H21S TEM6A0C36H31S TEM6A0C42H41S TEM6A0C48H41S TEM6A0D48H41S TEM6A0C60H51S TEM6A0D60H51S The TEM6 series air handler is designed
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM6A0B24H21SB TEM6A0B30H21SB TEM6A0C36H31SB TEM6A0C42H41SB TEM6A0C48H41SB TEM6A0D48H41SB TEM6A0C60H51SB TEM6A0D60H51SB The TEM6 series air handler is designed
More informationVariable Speed Modular Multi-position Communicating Air Handlers 2-5 Tons
Variable Speed Modular Multi-position Communicating Air Handlers 2-5 Tons TAM8A0A24V21CB TAM8A0B30V21CB TAM8A0C36V31CB TAM8A0C42V31CB TAM8A0C48V41CB TAM8A0C60V51CB TAM8B0C60V51CB PUB. NO. 22-1856-04 Features
More informationProduct Data. Convertible Air Handlers 1 1/2 5Ton
Product Data Convertible Air Handlers 1 1/2 5Ton TEM6A0B24H21S TEM6A0B30H21S TEM6A0C36H31S TEM6A0C42H41S TEM6A0C48H41S TEM6A0D48H41S TEM6A0C60H51S TEM6A0D60H51S The TEM6 series air handler is designed
More informationVariable Speed Modular Multi-position Air Handlers 2-5 Tons
Variable Speed Modular Multi-position Air Handlers 2-5 Tons TAM7A0A24H21SB TAM7A0B30H21SB TAM7A0C36H31SB TAM7A0C42H31SB TAM7A0C48H41SB TAM7A0C60H51SB TAM7B0C60H51SA PUB. NO. 22-1847-04 Features and Benefits
More information2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil
Specification 2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,
More information3 1/2 Ton Convertible Air Handler TAM7A0C42H31SD Standard Coil TAM7A0C42H31EA Black Epoxy Coil
Specification 3 1/2 Ton Convertible Air Handler TAM7A0C42H31SD Standard Coil TAM7A0C42H31EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,
More informationSpecification. 3 Ton Convertible Air Handler TAM7A0C36H31SC TAM7A0C36 SPEC-1D
Specification 3 Ton Convertible Air Handler TAG: SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler /RHT- Series Constant Torque (ECM) Efficiencies up to 16 SEER /RHT feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most
More informationB6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS 6VMMX Series Air Handler with TXV 18,000-60,000 tuh (Heat Pump & Air Conditioner) The 6VMMX Series of air handlers, when combined with our heat pump or air conditioner, offers
More informationTECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE
TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application
More informationPACKAGE HEAT PUMP UNITS
PACKAGE HEAT PUMP UNITS FOM NO. PTZ-77 EV. Supersedes Form No. PTZ-77 ev. 2 Featuring Earth-Friendly -40A efrigerant earth friendly refrigerant TZCHC- SEE HIGH EFFICIENCY SEIES NOMINAL SIZES -5 TONS [0.6-7.6
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable
More informationELECTRIC HEAT AIR HANDLERS
ELECTRIC HEAT AIR HANDLERS 208/230V 1 1 /2 to 5 TONS High efficiency series for R-22 Certain models feature GE s new X-13 motor for enhanced SEER performance with most outdoor condensing units Multi-position
More informationAIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal
More informationTECHNICAL GUIDE. COOLING & HEAT PUMP MODELS: F2RP024 THRU Hz SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS
036-21624-001 ev. A (1104) TECHNICAL GUIDE COOLING & HEAT PUMP S: F2P024 THU 060 50 Hz SINGLE PIECE AI HANDLES FO USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS Due to continuous product improvement, specifications
More informationB6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS 6EMMX Series Air Handler with TXV 14-15 SEER Residential System 18,000-60,000 tuh (Heat Pump & Air Conditioner) R-410A Refrigerant The 6EMMX Series of air handlers, when combined
More informationAIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.
FORM NO. H22-523 REV. 4 Supersedes Form No. H22-523 Rev. 3 AIR HANDLERS AIR HANDLERS UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant Features earth friendly
More informationFORM NO. HSC-543 AIR HANDLERS
FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure
More informationAIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features
FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient
More informationRheem High Efficiency Air Handler
Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable
More informationSPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B American Standard Inc. All Rights Reserved
SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B 2005 American Standard Inc. All Rights Reserved PUB. NO. 12-1194-02 February 2005 Features and Benefits Two Duration
More informationHyperion Field Reference Data TAM7
Hyperion Field Reference Data TAM7 Air Handler - Convertible Models: Series 7 Air Handlers 2-5 Ton *AM7A0A24H2SA, *AM7A0B30H2SA *AM7A0C36H3SA, *AM7A0C42H3SA *AM7A0C48H4SA, *AM7A0C60H5SA * May be "A" or
More informationAIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available
More informationAIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION
FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal
More informationAVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.
Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...
More informationProduct Data. Variable Speed Modular Multi-position Air Handlers 2 5 Tons
Product Data Variable Speed Modular Multi-position Air Handlers 2 5 Tons TAM9A0A24V21DA TAM9A0B30V31DA TAM9A0C36V31DA TAM9A0C42V41DA TAM9A0C48V41DA TAM9A0C60V51DA Note: Graphics in this document are for
More informationSPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved
SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B 2005 American Standard Inc. All Rights Reserved PUB. NO. 12-1200-02 March 2005 Features and Benefits Duration staged scroll
More informationAIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS
FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed
More informationRuud High Efficiency Air Handler
Air Handlers Ruud High Efficiency Air Handler RHLL- Series X-1 (ECM) Efficiencies up to 16 SEER RHLL feature an X-1 (ECM) motor which provides enhanced SEER performance with most Ruud outdoor units. Versatile
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES
TEHNIAL GUIDE SINGLE PIEE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLING & HEAT PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 DESRIPTION This fan coil line offers the ultimate in application flexibility.
More informationRheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor
Air Handlers Rheem Air Handlers RHLP- Standard Efficiency X-13 (ECM) Motor RHLP features an X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 1 1 /2 ton [.3 kw] through
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS
COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed
More informationELITE SERIES R-410A Ready - Multi-Position
PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER
More informationARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features
Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit
More informationFEM4X, FSM4X, FSU4X. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT, FSU4X Product Specifications FAN COILS ALL MODELS Available for Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin
More informationB Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor
SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More informationSTELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING
(598) STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING HEAT PUMP S: F2RP / F2FP018 THRU 060 COOLING S: F2RC / F2FC018 THRU 036 VARIABLE SPEED : F2FV060 DESCRIPTION This fan coil
More informationAir Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011)
Air Handlers ACBX32CM 3 Phase Multi-Position ACBX32CM-100 (07/2011) FEATURES AND BENEFITS Application Environmentally friendly R410A refrigerant 3, 4, and 5 ton nominal capacities Multi-position applications
More informationDIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE
DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806
TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS HEAT PUMP MODELS: F2RP/F2FP018 THRU 060 F3RP/F3FP018 THRU 060(T) FXRP024 THRU 060 COOLING MODELS F2RC/F2FC024 THRU
More informationODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz
ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz Condensing Models TTK 060 KD TTA 075 RD TTA 100 RD TTA 120 RD TTA 150 RD TTA 180 RD TTA 200 RD TTA 240 RD Air
More informationDESCRIPTION FEATURES
TECHNICAL GUIDE MODELS: N*AH Modular Air Handlers For use w / Split System Cooling & Heat Pump 600-2000 CFM Blowers 2-5 Ton Coils Optional 1 & 3 Electric Heaters DESCRIPTION This unique modular system
More informationHMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS HMG Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG Series of air handlers, when combined with our heat pump or air conditioner,
More informationDAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower
E N G I N E E R I N G D A T A A I R H A N D L E R S C31MV DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable lower ulletin No. 210107 July 2007 Supersedes January 2007 Nominal Capacity 3 to 5 Tons
More information80 TDD2B060,080, C100,D120A9V
Downflow/Horizontal Right or Downflow/Horizontal Left 2-Stage, Variable Speed Gas-Fired Furnace XV 80 TDD2B060,080, C100,D120A9V Two-Stage Fan Assisted Combustion System TDD-D-1 PUB. NO. 22-1673-07 General
More informationXV 80 TDD2B060,080, C100,D120A9V
Downflow/Horizontal Right or Left 2-Stage Variable Speed Gas-Fired Furnace XV 80 TDD2B060,080, C100,D120A9V Two-Stage Fan Assisted Combustion System PUB. NO. 22-1673-10 General Features NATURAL GAS MODELS
More informationHMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS HMG*T Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG*T series of air handlers, when combined with our heat pump or air conditioner, offer
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationMERIT Series R-410A - Upflow / Horizontal - Variable Speed
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0
More information36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH
36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua
More information24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)
24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More information1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5
TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum
More informationPACKAGE GAS ELECTRIC UNITS
PACKAGE GAS ELECTIC UNITS FOM NO. TZ-870 EV. 1 TZGE4 14 SEE SEIES NOMINAL SIZES 2-5 TONS [7.0-17.6 kw] TZGE5 15 SEE SEIES NOMINAL SIZES 2-5 TONS [7.0-17.6 kw] NL 1 PL 14.0 L 16.0 ATED IN ACCODANCE (15
More informationA I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S
P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric
More informationSplit System Cooling Product & Performance Data
SS-PRC012-EN Split System Cooling Product & Performance Data XB10 2TTB0030-060A 2½ 5 Tons PUB.. 22-1739-01-0402 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTB0 split systems
More information12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT
Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available
More informationFEM4P, FSM4P, FSU4P. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT FEM4P, FSM4P, FSU4P Product Specifications FAN COILS ALL MODELS 1 1/2 thru 4 tons Available for environmentally sound R 410A systems Factory installed piston metering
More informationBCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY
PRODUCT SPECIFICATIONS APPLICATION 2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (11/2018) INSTALLATION One piece design Smaller profile for closet
More informationPA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE
PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on
More information135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944)
ENVIRONMENTALLY SOUND REFRIGERANT Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for Environmentally Sound R 410A systems Bolt
More informationDimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT
ENVIRONMENTALLY SOUND REFRIGERANT B Series Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two--stage outdoor units Available for Environmentally Sound R--410A systems
More informationELITE Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX7UH ELITE Series R-0A - Upflow / Horizontal Bulletin No. 08 March 0 Supersedes October 0 Nominal Capacity -. to Tons Optional Electric Heat -. to kw MODEL NUMBER
More informationMB6(B,E,V)M Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Modular Indoor Blower 13+ SEER Residential System. Additional MB6EM Features:
TECHNICAL SPECIFICATIONS MB6(B,E,V)M Series Modular Indoor Blower 13+ SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The MB6 Series Modular Indoor Blower offers exceptional flexibility
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS
550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated
More informationB6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)
TECHNICAL SPECIFICATIONS B6BMMX Series Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The B6BMMX series of air handlers, when combined with our heat pump or air conditioner,
More informationBCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY
PRODUCT SPECIFICATIONS APPLICATION 1 1/2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (12/2018) INSTALLATION 1 piece design Smaller profile for
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationCFM Range Tons x 21 1 / 8 x x 21 FVM*X4800A 48, FVM*X6000A 60, x 24 x x
FVM Product Specifications VARIABLE SPEED FAN COILS ALL MODELS 2, 3, 4, and 5 Tons Supports two stage outdoor units Available for R 22 or Environmentally Sound R 410A systems Bolt on, hard shut off TXV
More informationXV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE
UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB TUD2B080A9V3VB TUD2C080A9V4VB TUD2C080B9V4VB TUD2B00A9V3VB TUD2C00A9V5VB TUD2C00B9V5VB TUD2DA9V5VB TUD2DB9V5VB TUD2DA9V5VB
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationMHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3
MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model
More informationARUF Series Multi-Position
Series Multi-Position Multi-speed Psc Motor Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed PSC blower motor All-aluminum evaporator coil Coil mounting
More informationTECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: CF, CM, CU 600-2000 CFM 1.5-5 TON COILS 5005744-BTG-C-0815 DESCRIPTION These indoor coils are designed to be installed
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationIllusion Split System
Illusion Split System Split System Air Conditioning (Concealed Type) -5 Ton - 50 Hz - R 22 Indoor Units MCD52DB MCD58DB MCD524DB MCD530DB MCD536DB MCD048DB MCD060DB Outdoor Units 2TTB052AA000D 2TTB058AA000D
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHX SERIES YTG-A-0409
TEHNIAL UIDE SINLE PIEE AIR HANDLERS FR USE WITH SPLIT-SYSTEM LIN & HEAT PUMPS MDELS: AHX SERIES DESRIPTIN This air handler line offers the ultimate in application flexibility. The AHX (high efficiency
More informationARPF. Air Handler with Painted Cabinet. 1½ to 5 Tons Multi-Position,
Air Handler with Painted Cabinet Standard Features Suitable for use with refrigerants -40A and - Check flowrater expansion device Direct-drive, multi-speed motor Transformer and blower time-delay on all
More informationGQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY
TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can
More informationXC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace
TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VA, TDHMB060BCV3VA TUHMB080ACV3VA, TDHMB080ACV3VA
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationProduct Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits
More informationHEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H66-515 Supersedes Form No. H66-5 Rev. 1 HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35 inches [889 mm] tall and 22 inches
More informationCased/Uncased Coils For Gas And Oil Furnaces
MODEL: TCF Cased/Uncased Coils For Gas And Oil Furnaces FORM NO. CSC-224 REV. 1 Sure Comfort TCF Cased/Uncased Coils For Gas And Oil Furnaces (TXV Metering Device Shown) Featuring Industry Standard R-410A
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationQ6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase
TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationPage Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6
TC-SGRAH1-1005 October 05 R Series - High Efficiency Multi-position Air Handler Engineering and Specification Guide (Electric and No Heat) With optional field conversion downflow kit Contents: Page Number
More informationPHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP
PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only
More informationService Facts. WARNING: HAZARdOuS VOLTAGE - disconnect POWER and discharge 4TWZ0024-SF-1F. ComfortLink II System Heat Pump 4TWZ0024A1000A.
Service Facts ComfortLink II System Heat Pump 4TWZ0024A1000A 4TWZ0024A1000A 200/230/1/60 14 20 CLIMATUFF 2-2 200/230/1/60 8.7-58 YES YES YES PROPELLER 27.6-1 DIRECT - 2 3390/2270 1-1/3 759/493 200/230/1/60
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More information