Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz, CE Units

Size: px
Start display at page:

Download "Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz, CE Units"

Transcription

1 Product Data 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz, CE Units Nominal Capacity: 21.5 kw to 35.9 kw (6.1 to 10.2 Tons) Single-Package Rooftop Units with: European Community (CE) design Galvanized steel cabinet with Carrier Weather Armor coating Fifty-one mm (2-in.) return-air filters Commercial strength base rails Exclusive tool-less filter access panel Corrosion-resistant sloped condensate pan Single power entry to unit Commercial duty motors with permanently lubricated bearings Standard cooling operation at outdoor ambient temperatures as low as 4 C (25 F) Meets ASHRAE Standard 62 (U.S.A.) for Indoor-Air Quality (IAQ) Features/Benefits Compact, vertical discharge units convert to horizontal discharge, combining installation flexibility with efficient performance and easy maintenance. Easy installation and conversion All units are shipped in the vertical discharge configuration for fit-up to standard roof curbs. The contractor can order and install the roof curb early in the construction stage, before decisions on size requirements are made. All units feature roll-formed baserail design with forklift slots on all 3 sides and rigging holes for easier maneuvering. Durable packaging protects all units during shipment and storage. Copyright 1995 Carrier Corporation Form 50TJ-C4PD

2 The units can be easily converted from a vertical to a horizontal discharge configuration by interchanging the panels supplied with the unit. All units feature a non-corrosive sloped condensate drain pan in accordance with ASHRAE (American Society of Heating, Refrigeration and Air Conditioning Engineers) Standard 62. Also, the new, sloped condensate pan permits either an external side condensate drain (outside the roof curb) or an internal bottom drain (inside the roof curb). Both options require an external, field-supplied P-trap. Plus, the condenser coil grille (available as a field-installed accessory) provides a metal plate as an alternate location for the fieldsupplied disconnect, if desired. In addition, the 50TJ units have a standard filter access door, which permits tool-less filter changes and provides an opening for outdoor air options and accessories. Field-installed electric heaters are available in a wide range of capacities. Single point wiring kit makes installation simple. Simple electrical connections Terminal boards, located in the base unit control box, facilitate connections to room thermostat, outdoor thermostat(s), economizer, and electric heat. Service panels are quickly removed, permitting easy servicing. Thru-the-bottom service connection capability allows power and control wiring to be routed through the unit basepan, minimizing roof penetrations. Both power and control connections are made on the same side of the unit to simplify installation. Proven compressor reliability Design techniques feature computerprogrammed balance between compressor, condenser, and evaporator. Carrierspecified hermetic compressors are equipped with compressor overcurrent and overtemperature protection to ensure dependability. Carrier s exclusive Acutrol metering device precisely controls refrigerant flow, preventing slugging and flood-back, while maintaining optimum unit performance. Durable, dependable construction Designed for durability in any climate, the weather-resistant cabinets are manufactured using Carrier Weather Armor coating. The cabinet is constructed of galvanized steel, is bonderized, and all exterior panels are coated with a prepainted baked enamel finish. The paint finish is non-chalking, and is capable of withstanding Federal (U.S.A.) Test Method Standard No. 141 (Method 6061) 500-hour salt spray test. All internal cabinet panels are primed, permitting longer life and a more attractive appearance for the entire unit. In addition, the 50TJ units are designed with a single, continuous top piece to eliminate any possible leaks. Totally-enclosed condenser-fan motors and permanentlylubricated bearings provide additional unit dependability. Integrated economizers and outdoor air During a first stage call for cooling, if the outdoor-air temperature is below the control set point, the leaving-air sensor modulates the economizer outdoor-air damper open to achieve the set point. When second-stage cooling is called for, the compressor is energized in addition to the economizer. If the outdoor-air temperature is above the set point, the first stage of compression is activated and the economizer stays at minimum vent position. Economizer operation is controlled by Accusensor I dry-bulb thermostat that senses outdoor-air temperature. Accessory upgrade kits include solid-state enthalpy control and differential enthalpy sensor. The Durablade economizer has a reliable sliding plate damper which is easily adjusted for 100% outdoor air, 100% return air, or any proportions of mixed air. Quiet, efficient operation and dependable performance Compressors have vibration isolators for extremely quiet operation. Efficient fan and motor design permits operation at very low sound levels, and all units are mounted on independent mounting rails. Quiet and efficient operation is provided by belt-driven evaporator fans (standard). The belt-driven evaporator-fan motors allow adjustment to available static pressure to meet the job requirements of even the most demanding applications. Indoor-air quality begins with Carrier rooftops Sloped condensate pans minimize biological growth in rooftop units in accordance with ASHRAE Standard 62. Fifty-one mm (2-in.) filters with optional dirty filter indicator switch provide for greater particle reduction in the return air. The face-split evaporator coils improve the dehumidification capability of the standard units, and standard enthalpy controls provided with the optional or accessory economizers maximize building humidity control. The units also have an accessory, 100% open, two-position damper to meet all your fresh outdoor air requirements. For units without economizer, yearround ventilation is enhanced by a manual outdoor-air damper (ordered as an accessory). The damper can be preset to admit up to 25% outdoor air. Euro-style control box Control box is designed in accordance with IEC (International Electrotechnical Commission) standards and complies with harmonized European Standard EN The control box is factory installed and features: single-color, specially routed wiring with supports fully shrouded terminal blocks for field power connection no sharp edges on wire paths earth bonding transformer which meets IEC742 EURO-STYLE CONTROL BOX 2

3 Table of contents Page Features/Benefits...1,2 Model Number Nomenclature...3 Physical Data...4,5 Options and Accessories...6,7 Base Unit Dimensions...8 Accessory Dimensions...9 Selection Procedure...10,11 Performance Data Electrical Data...26 Typical Piping and Wiring...27 Typical Wiring Schematic...28,29 Controls...30 Application Data...31 Guide Specifications Model number nomenclature Al Aluminum Cu Copper FIOP Factory-Installed Option *Refer to 50TJ Product Ordering Data or contact your local Carrier representative for 50TJ FIOP code table. All coils have copper tubes. Contact your local Carrier representative for more details regarding coil fin options B, C, D, and V. **50TJ only. 3

4 Physical data (SI) UNIT SIZE NOMINAL CAPACITY (kw) OPERATING WEIGHT (kg) Unit Al/Al* Economizer Roof Curb COMPRESSOR Hermetic Quantity Oil (ml) 1479 ea 1479 ea 1479 ea 1922 ea REFRIGERANT TYPE R-22 Operating Charge (kg) Circuit Circuit CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced Fins Rows...Fins/m Total Face Area (sq m) CONDENSER FAN Propeller Type Nominal L/s Quantity...Diameter (mm) Motor BkW...r/s EVAPORATOR COIL Enhanced Copper Tubes, Aluminum Double-Wavy Fins, Acutrol Feed Device Rows...Fins/m Total Face Area (sq m) EVAPORATOR FAN Centrifugal Type Quantity...Size (mm x mm) x x x x 381 Type Drive Belt Belt Belt Belt Nominal L/s Motor kw Maximum Continuous BkW Motor Frame Size Fan r/s Range Motor Bearing Type Ball Ball Ball Ball Maximum Allowable r/s Motor Pulley Pitch Diameter Min/Max (mm) 61/86 61/86 86/ /127 Nominal Motor Shaft Diameter (mm) Fan Pulley Pitch Diameter (mm) Nominal Fan Shaft Diameter (mm) Belt, Quantity...Type...Length (mm) 1...A A A A Pulley Center Line Distance (mm) Speed Change per Full Turn of Movable Pulley Flange (r/s) Movable Pulley Maximum Full Turns From Closed Position Factory Setting Factory Speed Setting (r/s) Fan Shaft Diameter at Pulley (mm) HIGH-PRESSURE SWITCH (kpa)** Standard Compressor Internal Relief (Differential) 3103 ± ± 345 Cutout 2951 Reset (Auto.) 2206 LOW-PRESSURE SWITCH (kpa)** Cutout 48±21 Reset (Auto.) 152±48 FREEZE PROTECTION THERMOSTAT** Opens (C) 1 Closes (C) 7 OUTDOOR-AIR INLET SCREENS Cleanable Quantity...Size (mm) x 635 x x 635 x 25 RETURN-AIR FILTERS Throwaway Quantity...Size (mm) x 508 x x 508 x x 508 x x 508 x 51 Al Aluminum Bhp Brake Horsepower BkW Fan Input Watts x Motor Efficiency Cu Copper *Evaporator coil fins/condenser coil fins. Weight of 356 mm roof curb. **Requires the accessory/optional Controls Upgrade Kit. NOTE: The 50TJ units have a loss-of-charge/low-pressure switch (accessory/option) located in the liquid line. 4

5 Physical data (English) UNIT SIZE NOMINAL CAPACITY (tons) OPERATING WEIGHT (lb) Unit Al/Al* Economizer Roof Curb COMPRESSOR Hermetic Quantity Oil (oz) 50 ea 50 ea 50 ea 65 ea REFRIGERANT TYPE R-22 Operating Charge (lb-oz) Circuit Circuit CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced Fins Rows...Fins/in Total Face Area (sq ft) CONDENSER FAN Propeller Type Nominal Cfm Quantity...Diameter (in.) Motor Hp...Rpm EVAPORATOR COIL Enhanced Copper Tubes, Aluminum Double-Wavy Fins, Acutrol Feed Device Rows...Fins/in Total Face Area (sq ft) EVAPORATOR FAN Centrifugal Type Quantity...Size (in.) x x x x 15 Type Drive Belt Belt Belt Belt Nominal Cfm Motor Hp Maximum Continuous Bhp Motor Frame Size Fan Rpm Range Motor Bearing Type Ball Ball Ball Ball Maximum Allowable Rpm Motor Pulley Pitch Diameter Min/Max (in.) 2.4/ / / /5.0 Nominal Motor Shaft Diameter (in.) Fan Pulley Pitch Diameter (in.) Nominal Fan Shaft Diameter (in.) Belt, Quantity...Type...Length (in.) 1...A A A A...51 Pulley Center Line Distance (in.) Speed Change per Full Turn of Movable Pulley Flange (rpm) Movable Pulley Maximum Full Turns From Closed Position Factory Setting Factory Speed Setting (rpm) Fan Shaft Diameter at Pulley (in.) HIGH-PRESSURE SWITCH (psig)** Standard Compressor Internal Relief Differential) 450±50 500±50 Cutout 428 Reset (Auto.) 320 LOW-PRESSURE SWITCH (psig)** Cutout 7±3 Reset (Auto.) 22±7 FREEZE PROTECTION THERMOSTAT** Opens 30±5 Closes 45±5 OUTDOOR-AIR INLET SCREENS Cleanable Quantity...Size (in.) x 25 x x 25 x 1 RETURN-AIR FILTERS Throwaway Quantity...Size (in.) x 20 x x 20 x x 20 x x 20 x 2 Al Aluminum Bhp Brake Horsepower BkW Fan Input Watts x Motor Efficiency Cu Copper *Evaporator coil fins/condenser coil fins. Requires the accessory/optional Controls Upgrade Kit. **Weight of 14-in. roof curb. NOTE: The 50TJ units have a loss-of-charge/low-pressure switch (accessory/option) located in the liquid line. 5

6 Options and accessories ITEM OPTION* ACCESSORY Unit-Mounted Disconnect X Durablade Integrated Economizer (Includes Hood) X X Manual Outdoor-Air Damper X Controls Upgrade Kit X** X Condenser Coil Grille X Electric Heat X 25% Open Two-Position Damper X 100% Open Two-Position Damper X Roof Curbs (Vertical and Horizontal Discharge) X Remote Control Panel X Thermostats and Subbases X Time Guard II Control Circuit X Thru-the-Bottom Service Connections X Accusensor II Enthalpy Control X Accusensor III Enthalpy Sensor X Condenser Coil Hail Guard Assembly X Fan/Filter Status X Salt Spray Protection Grille X *Factory installed. Field installed. **Includes high pressure, loss-of-charge/low pressure, and freeze protection switches. HAIL GUARD AND CONDENSER COIL SALT-SPRAY PROTECTION THERMOSTAT Zone thermostat (24 v) provides one- or 2-stage cooling for control of unit. Matching subbases are available with or without tamperproof switches and automatic changeover. COIL GUARD GRILLE Condenser coil hail guard accessory protects coil against damage from hail and other flying debris. Condenser coil salt spray protection accessory protects coils from salt spray induced corrosion in coastal areas, and utilizes a cleanable filter. Coil guard grille protects coils against large objects and vandalism. 6

7 OUTDOOR TEMP. F 55 S OPEN 1 3 T T1 B C D TR P P1 DAMPER OPEN DAMPER CLOSED D C B A OR UNPOWERED STATE CW SETPOINTS CCW VAC ACCUSENSOR II ACCUSENSOR III % H U M I D I T Y MINIMUM POSITION RUSH AT 24VAC 3 ma MIN. AT 11 VDC CONTACT RATINGS: 1.5A RUN, 3.5A IN CONTACTS SHOWN IN HIGH ENTHALPY TR TR1 ENTHALPY CONTROL SO REV. B A + Accusensor economizer controls help provide efficient, economical economizer operation. The Accusensor I dry-bulb sensor measures outdoor temperature and is standard with the economizer. The accessory Accusensor II solid-state enthalpy control senses both dry and wet bulb of the outdoor air to provide an accurate enthalpy reading. Accusensor II is available as a field-installed accessory for the economizer. The accessory Accusensor III differential enthalpy sensor compares outdoor temperature and humidity to returnair temperature and humidity and determines the most economical mixture of air. Accusensor III is available as a field-installed accessory for the economizers REV UNIT MOUNTED DISCONNECT TIME GUARD II CONTROL Time Guard II Control automatically prevents compressor from restarting for at least 5 minutes after a shutdown. Field-installed accessory prevents short cycling of compressor if thermostat is rapidly changed. Time Guard II device mounts in the control compartment of unit. DURABLADE ECONOMIZER Factory-installed, internally-mounted, NEC and UL (U.S.A. Standards) approved non-fused switch provides unit power shutoff and disconnect lockout protection capability. The switch is accessible from outside the unit. ELECTRIC HEATER Electric heaters are available in a wide range of capacities for field installation. Exclusive Durablade economizer damper design saves energy while providing economical and reliable cooling. A sliding plate on the face of the economizer controls the amount of outdoor air entering the system. When the sliding plate is closed, it provides a leakproof seal which prevents ambient air from seeping in or conditioned air from seeping out. It can be easily adjusted for 100% outdoor air or any proportion of mixed air. 7

8 Base unit dimensions STD UNIT WEIGHT CORNER WEIGHT (A) CORNER WEIGHT (B) CORNER WEIGHT (C) CORNER WEIGHT (D) UNIT H J K 50TJ Lb Kg Lb Kg Lb Kg Lb Kg Lb Kg Ft-in. mm Ft-in. mm Ft-in. mm A B C D E F CONNECTION SIZES dia [35] field power supply hole dia [64] power supply knockout dia [44] charging port hole 7 8 [22] field control wiring hole NPT condensate drain 2 dia [51] power supply knockout BOTTOM POWER CHART: THESE HOLES REQUIRED FOR USE WITH ACCESSORY PACKAGES CRBTMPWR001A00 ( 1 2, 3 4 ) OR CRBTMPWR002A00 ( 1 2, ) THREADED CONDUIT SIZE WIRE USE REQ D HOLE SIZES (MAX.) v 7 8 [22.2] 3 4 POWER* [28.4] POWER* [44.4] *Select either 3 4 or for power, depending on wire size. 1. Dimensions in [ ] are in millimeters. 2. Center of gravity. 3. Direction of airflow. 4. Ductwork to be attached to accessory roof curb only. 5. Minimum clearance (local codes or jurisdiction may prevail): a. Bottom to combustible surfaces (when not using curb) 0 inches. On horizontal discharge units with electric heat 1 in. clearance to ductwork for 1 ft. b. Condenser coil, for proper airflow, 36 in. one side, 12 in. the other. The side getting the greater clearance is optional. c. Overhead, 60 in. to assure proper condenser fan operation. d. Horizontal supply and return end, 0 inches. 6. With the exception of the clearance for the condenser section or combustibles as stated in Notes 5a, b, and c, a removable fence or barricade requires no clearance. 7. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material. 8. The vertical center of gravity is [495] for 008 and 009, 2-0 [610] for 012 and 014 up from the bottom of the base rail. Horizontal center of gravity is shown. 8

9 Accessory dimensions ROOF CURB A 1-2 [356] 2-0 [610] ROOF CURB ACCESSORY CRRFCURB003A00 CRRFCURB004A00 B [827] C [583] D ALT DRAIN HOLE [45] CONNECTION SIZES POWER CONNECTION CONTROL CONNECTION 3 4 NPT 1 2 NPT NPT 1 2 NPT CONNECTOR ACY PKG CRBTMPWR001A00 (Thru-the-Bottom) CRBTMPWR002A00 (Thru-the-Bottom) 1. Roof curb accessory is shipped unassembled. 2. Insulated panels. 3. Dimensions in [ ] are in millimeters. 4. Roof curb: galvanized steel. 5. Attach ductwork to curb (flanges of duct rest on curb). 6. Service clearance 4 ft on each side. 7. Direction of airflow. 8. Either accessory connector package can be used with either accessory roof curb. 9

10 Selection procedure (with 50TJ012 example) SI I Determine cooling and heating requirements at design conditions. Given: Required Cooling Capacity (TC)...28kW Sensible Heat Capacity (SHC)...19kW Required Heating Capacity...18kW Condenser Entering-Air Temp...36C Evaporator Entering-Air Temp C edb, 20 C ewb Evaporator Air Quantity L/s External Static Pressure (ESP) Pa Electrical Characteristics (V-Ph-Hz) Edb Entering dry bulb Ewb Entering wet bulb II Select unit based on required cooling capacity. Enter the 50TJ012 Cooling Capacities table on page 14 at condenser entering temperature of 36 C, evaporatorair entering at 1520 L/s, 26.7 C db and 20 C wb. The 50TJ012 unit will provide cooling capacity of 30.1 kw and a sensible heat capacity of 21.2 kw. For evaporator-air temperature other than 26.7 C edb, calculate sensible heat capacity correction, as required, using the formula found in the notes following the Cooling Capacities table on page 15. NOTE: Unit ratings are gross capacities and do not include the effect of evaporator (indoor) fan motor (IFM) heat. To calculate net capacities, see Step V. III Select electric heat: Heating load required is 18 kw. Enter the Electric Heating Capacities table (page 25) for the 50TJ012 at The 19.3 kw heater at 400 v most closely satisfies the heating required. To calculate kw at 380 v, use the Multiplication Factors table on page x.902 = 17.4 kw gross capacity IV Determine fan speed and power requirements at design conditions. Before entering the Fan Performance tables, calculate the total static pressure required based on unit components. From the given and the Pressure Drop tables (page 25), find: External static pressure 300 Pa Economizer 9 Pa Electric Heat 14 Pa Total static pressure 323 Pa Enter the Fan Performance table for the 50TJ012 vertical discharge unit on page 20. Find the fan r/s and kilowatts at 323 Pa and 1520 L/s. Note that the fan speed is 14.5 r/s and power required is 1.56 kw (interpolation required). The standard motor will adequately handle the job requirements. V Determine net capacities. Capacities are gross and do not include the effect of evaporator-fan motor heat. Use IFM kw from Fan Performance table on page 20. Determine net cooling capacity as follows: Net capacity = gross capacity IFM kw = 30.1 kw 1.56 kw = 28.5 kw Net sensible capacity = 21.2 kw 1.56 kw = 19.6 kw Determine net heating capacity as follows: Net capacity = gross capacity IFM heat = 17.4 kw 1.56 kw = 18.9 kw 10

11 Selection procedure (with 50TJ012 example) English I Determine cooling and heating requirements at design conditions. Given: Required Cooling Capacity (TC)... 96,000 Btuh Sensible Heat Capacity (SHC)...70,000 Btuh Required Heating Capacity...62,000 Btuh Condenser Entering-Air Temp...95F Evaporator Entering-Air Temp...80Fedb, 67 F ewb Evaporator Air Quantity cfm External Static Pressure (ESP) in. wg Electrical Characteristics (V-Ph-Hz) Edb Entering dry bulb Ewb Entering wet bulb II Select unit based on required cooling capacity. Enter the 50TJ012 Cooling Capacities table on page 17 condenser entering temperature of 95 F, evaporator-air entering at 3200 cfm, 80 F db and 67 F wb. The 50TJ012 unit will provide cooling capacity of 102,500 Btuh and a sensible heat capacity of 76,000 Btuh. For evaporator-air temperature other than 80 F edb, calculate sensible heat capacity correction, as required, using the formula found in the notes following the Cooling Capacities table on page 17. NOTE: Unit ratings are gross capacities and do not include the effect of evaporator-fan motor (IFM) heat. To calculate net capacities, see Step V. III Select electric heat: Heating load required is 62,000 Btuh. 62,000 Btuh = 18.2 kw of heat required 3413 Btuh/kW Enter the Electric Heating Capacities table (page 25) for the 50TJ012 at The 19.3 kw heater at 400 v most closely satisfies the heating required. To calculate kw at 380 v, use the Multiplication Factors table on page x.902 = 17.4 kw 19.3 x.902 x 3413 = 59,416 Btuh gross capacity IV Determine fan speed and power requirements at design conditions. Before entering the Fan Performance tables, calculate the total static pressure required based on unit components. From the given and the Pressure Drop tables (page 25) find: External static pressure 1.10 in. wg Economizer 0.03 in. wg Electric Heat 0.06 in. wg Total static pressure 1.19 in. wg Enter the Fan Performance table for the 50TJ012 vertical discharge unit on page 23. Find the fan rpm and watts at 1.19 in. wg and 3200 cfm. Note that the fan speed is 842 rpm and power required is 1423 Watts. (Interpolation is required.) The standard motor will adequately handle the job requirements. V Determine net capacities. Capacities are gross and do not include the effect of evaporator-fan motor heat. Use IFM Watts from Fan Performance table on page 23. Determine net cooling capacity as follows: Net capacity = gross capacity IFM Watts = 102,500 Btuh 1423 Watts x Btuh Watts = 102,500 Btuh 4857 Btuh = 97,643 Btuh Net sensible capacity = 76,000 Btuh 4857 Btuh = 71,143 Btuh Determine net heating capacity as follows: Net Capacity = gross capacity IFM heat = 59, = 64,273 Btuh 11

12 Performance data 50TJ008 (21.5 kw) Temp (C) Air Entering Condenser (Edb) COOLING CAPACITIES SI Air Entering Evaporator L/s/BF 850/ /0.075 Air Entering Evaporator Ewb (C) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TJ008 (21.5 kw) (cont) Temp (C) Air Entering Condenser (Edb) Air Entering Evaporator L/s/BF 1180/ /0.095 Air Entering Evaporator Ewb (C) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw

13 50TJ009 (24.3 kw) Temp (C) Air Entering Condenser (Edb) COOLING CAPACITIES SI (cont) Air Entering Evaporator L/s/BF 900/ / /0.10 Air Entering Evaporator Ewb (C) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw AND NOTES FOR COOLING CAPACITY TABLES SI BF Bypass Factor Edb Entering Dry Bulb Temperature (C) Ewb Entering Wet Bulb Temperature (C) kw Compressor Input (kw) ldb Leaving Dry Bulb lwb Leaving Wet Bulb SHC Sensible Heat Capacity (kw) TC Total Capacity (kw) 1. Ratings are gross, and do not account for the effects of the evaporatorfan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 26.7 C db temperature of air entering the unit. At any other temperature, correct the SHC read from the table of cooling capacities as follows: Corrected SHC kw = SHC [1.23 x 10 3 x(1 BF)x(C db 26.7) x L/s] Observe the rule of sign. Above 26.7 C, SHC correction will be positive; add it to SHC. Below 26.7 C, SHC correction will be negative; subtract it from SHC. 4. Formulas: SHC kw x 1000 C ldb =C edb 1.23 x L/s Leaving wet bulb = wet bulb temperature corresponding to enthalpy of air leaving coil (h lwb ). TC kw x 1000 h lwb =h ewb 1.20 x L/s Where h ewb is enthalpy of air entering evaporator coil (kj/kg). 13

14 Performance data (cont) 50TJ012 (29.2 kw) Temp (C) Air Entering Condenser (Edb) COOLING CAPACITIES SI (cont) Air Entering Evaporator L/s/BF 1140/ /0.105 Air Entering Evaporator Ewb (C) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TJ012 (29.2 kw) (cont) Air Entering Evaporator L/s/BF Temp (C) Air Entering 1800/ /0.13 Condenser Air Entering Evaporator Ewb (C) (Edb) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw

15 50TJ014 (35.9 kw) Temp (C) Air Entering Condenser (Edb) COOLING CAPACITIES SI (cont) Air Entering Evaporator L/s/BF 1500/ / /0.22 Air Entering Evaporator Ewb (C) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw AND NOTES FOR COOLING CAPACITY TABLES SI BF Bypass Factor Edb Entering Dry Bulb Temperature (C) Ewb Entering Wet Bulb Temperature (C) kw Compressor Input (kw) ldb Leaving Dry Bulb lwb Leaving Wet Bulb SHC Sensible Heat Capacity (kw) TC Total Capacity (kw) 1. Ratings are gross, and do not account for the effects of the evaporatorfan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 26.7 C db temperature of air entering the unit. At any other temperature, correct the SHC read from the table of cooling capacities as follows: Corrected SHC kw = SHC [1.23 x 10 3 x(1 BF)x(C db 26.7) x L/s] Observe the rule of sign. Above 26.7 C, SHC correction will be positive; add it to SHC. Below 26.7 C, SHC correction will be negative; subtract it from SHC. 4. Formulas: SHC kw x 1000 C ldb =C edb 1.23 x L/s Leaving wet bulb = wet bulb temperature corresponding to enthalpy of air leaving coil (h lwb ). TC kw x 1000 h lwb =h ewb 1.20 x L/s Where h ewb is enthalpy of air entering evaporator coil (kj/kg). 15

16 Performance data (cont) 50TJ008 (6.1 TONS) Temp (F) Air Entering Condenser (Edb) COOLING CAPACITIES ENGLISH Air Entering Evaporator Cfm/BF 1950/ / / /0.095 Air Entering Evaporator Ewb (F) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TJ009 (6.9 TONS) Temp (F) Air Entering Condenser (Edb) Air Entering Evaporator Cfm/BF 1950/ / /0.10 Air Entering Evaporator Ewb (F) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw AND NOTES FOR COOLING CAPACITY TABLES ENGLISH BF Bypass Factor Edb Entering Dry Bulb Temperature (F) Ewb Entering Wet Bulb Temperature (F) kw Compressor Motor Power Input ldb Leaving Dry Bulb lwb Leaving Wet Bulb SHC Sensible Heat Capacity (1000 Btuh) TC Total Capacity (1000 Btuh) 1. Ratings are gross, and do not account for the effects of the evaporatorfan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 80 F db temperature of air entering the unit. At any other temperature, correct the SHC read from the table of cooling capacities as follows: Corrected SHC Btuh = SHC [1.10 x (1 BF)x(F db 80) x cfm] Observe the rule of sign. Above 80 F, SHC correction will be positive; add it to SHC. Below 80 F, SHC correction will be negative; subtract it from SHC. 4. Formulas: SHC F Btuh ldb =F edb 1.09 x cfm Leaving wet bulb = wet bulb temperature corresponding to enthalpy of air leaving coil (h lwb ). TC Btuh h lwb =h ewb 4.50 x cfm Where h ewb is enthalpy of air entering evaporator coil (Btu/lb). 16

17 50TJ012 (8.3 TONS) Temp (F) Air Entering Condenser (Edb) COOLING CAPACITIES ENGLISH (cont) Air Entering Evaporator Cfm/BF 2500/ / / /0.13 Air Entering Evaporator Ewb (F) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TJ014 (10.2 TONS) Temp (F) Air Entering Condenser (Edb) Air Entering Evaporator Cfm/BF 3150/ / /0.22 Air Entering Evaporator Ewb (F) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw AND NOTES FOR COOLING CAPACITY TABLES ENGLISH BF Bypass Factor Edb Entering Dry Bulb Temperature (F) Ewb Entering Wet Bulb Temperature (F) kw Compressor Motor Power Input ldb Leaving Dry Bulb lwb Leaving Wet Bulb SHC Sensible Heat Capacity (1000 Btuh) TC Total Capacity (1000 Btuh) 1. Ratings are gross, and do not account for the effects of the evaporatorfan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. SHC is based on 80 F db temperature of air entering the unit. At any other temperature, correct the SHC read from the table of cooling capacities as follows: Corrected SHC Btuh = SHC [1.10 x (1 BF)x(F db 80) x cfm] Observe the rule of sign. Above 80 F, SHC correction will be positive; add it to SHC. Below 80 F, SHC correction will be negative; subtract it from SHC. 4. Formulas: SHC F Btuh ldb =F edb 1.09 x cfm Leaving wet bulb = wet bulb temperature corresponding to enthalpy of air leaving coil (h lwb ). TC Btuh h lwb =h ewb 4.50 x cfm Where h ewb is enthalpy of air entering evaporator coil (Btu/lb). 17

18 Performance data (cont) FAN PERFORMANCE (SI) HORIZONTAL DISCHARGE UNITS 50TJ008,009 (21.5 AND 24.3 kw) STANDARD MOTOR (BELT DRIVE) External Static Pressure (Pa) R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw Airflow (L/s) BkW Fan Input kw x Motor Efficiency kw Kilowatt Input to Motor 1. Boldface indicates field-supplied drive required (see Note 3). 2. indicates field-supplied motor and drive required. 3. Factory-shipped drive range is to r/s. Other r/s s may require a field-supplied drive. 4. Values include losses for filters, unit casing, and wet coils. 5. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the kw ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. See Evaporator- Fan Motor Performance table on page 24 for additional information. 6. Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative to verify. 7. To convert kw to bkw: BkW = kw x Motor Efficiency Motor Efficiency:.81 Maximum Continuous kw: Interpolation is permissible. Do not extrapolate. 9. Static pressure losses (i.e., economizer, electric heater) must be added to external static pressure before entering Fan Performance table. 50TJ012 (29.2 kw) STANDARD MOTOR (BELT DRIVE) Airflow (L/s) External Static Pressure (Pa) R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw BkW Fan Input kw x Motor Efficiency kw Kilowatt Input to Motor 1. Boldface indicates field-supplied drive required (see Note 3). 2. indicates field-supplied motor and drive required. 3. Factory-shipped drive range is to r/s. Other r/s s may require a field-supplied drive. 4. Values include losses for filters, unit casing, and wet coils. 5. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the kw ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. See Evaporator- Fan Motor Performance table on page 24 for additional information. 6. Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative to verify. 7. To convert kw to bkw: BkW = kw x Motor Efficiency Motor Efficiency:.83 Maximum Continuous kw: Interpolation is permissible. Do not extrapolate. 9. Static pressure losses (i.e., economizer, electric heater) must be added to external static pressure before entering Fan Performance table. 18

19 FAN PERFORMANCE (SI) HORIZONTAL DISCHARGE UNITS (cont) 50TJ014 (35.9 kw) STANDARD MOTOR (BELT DRIVE) Airflow (L/s) External Static Pressure (Pa) R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw BkW Fan Input kw x Motor Efficiency kw Kilowatt Input to Motor 1. Boldface indicates field-supplied drive required (see Note 3). 2. indicates field-supplied motor and drive required. 3. Factory-shipped drive range is to r/s. Other r/s s may require a field-supplied drive. 4. Values include losses for filters, unit casing, and wet coils. 5. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the kw ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. See Evaporator- Fan Motor Performance table on page 24 for additional information. 6. Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative to verify. 7. To convert kw to bkw: BkW = kw x Motor Efficiency Motor Efficiency:.85 Maximum Continuous kw: Interpolation is permissible. Do not extrapolate. 9. Static pressure losses (i.e., economizer, electric heater) must be added to external static pressure before entering Fan Performance table. FAN PERFORMANCE (SI) VERTICAL DISCHARGE UNITS 50TJ008,009 (21.5 AND 24.3 kw) STANDARD MOTOR (BELT DRIVE) External Static Pressure (Pa) R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw R/s kw Airflow (L/s) BkW Fan Input kw x Motor Efficiency kw Kilowatt Input to Motor 1. Boldface indicates field-supplied drive required (see Note 3). 2. indicates field-supplied motor and drive required. 3. Factory-shipped drive range is to r/s. Other r/s s may require a field-supplied drive. 4. Values include losses for filters, unit casing, and wet coils. 5. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the kw ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. See Evaporator- Fan Motor Performance table on page 24 for additional information. 6. Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative to verify. 7. To convert kw to bkw: BkW = kw x Motor Efficiency Motor Efficiency:.81 Maximum Continuous kw: Interpolation is permissible. Do not extrapolate. 9. Static pressure losses (i.e., economizer, electric heater) must be added to external static pressure before entering Fan Performance table. 19

Product Data. Features/Benefits

Product Data. Features/Benefits Product Data 50TFF007-014 Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz Nominal Capacity: 17.6 kw to 35.9 kw (5 to 10.2 Tons) Single-Package Rooftop Units with: Galvanized

More information

Product Data. Features/Benefits

Product Data. Features/Benefits Product Data 50TFQ008-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 50 Hz Nominal Capacities: 26.4 to 35.2 kw (7 1 / 2 to 10 Nominal Tons) Single-package standard efficiency rooftop heat

More information

Product Data. Features/Benefits. 50TJQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons

Product Data. Features/Benefits. 50TJQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons Product Data 50TJQ004-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 3 to 10 Nominal Tons Single-package standard efficiency rooftop heat pumps with: State-of-the-art defrost system Dependable

More information

Product Data. Features/Benefits. 50TFQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons

Product Data. Features/Benefits. 50TFQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons Product Data 50TFQ004-012 Single-Package Standard Efficiency Rooftop Heat Pump Units 3 to 10 Nominal Tons Single-package standard efficiency rooftop heat pumps with: State-of-the-art defrost system Dependable

More information

Product Data. Features/Benefits. 48TJ Single-Package Rooftop Units Electric Cooling/Gas Heating 50 Hz

Product Data. Features/Benefits. 48TJ Single-Package Rooftop Units Electric Cooling/Gas Heating 50 Hz Product Data 48TJ008-014 Single-Package Rooftop Units Electric Cooling/Gas Heating 50 Hz Nominal Capacity: 21.5 kw to 35.9 kw (6.1 to 10.2 Tons) Single-Package Rooftop Units with: Alumagard heat exchanger

More information

Model 558D/559F Sizes

Model 558D/559F Sizes Bryant Air Conditioning COMMERCIAL SINGLE-PACKAGE ROOFTOP ELECTRIC COOLING UNITS Model 558D/559F Sizes 036-300 3to25Tons Model 558D036-072 Model 559F180,216 Model 558D090-150 Model 559F240,300 DESCRIPTION

More information

COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase)

COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase) PAE Product Specifications COMMERCIAL ASHRAE EFFICIENT PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

Product Data. Features/Benefits. 50TFF Single-Package Rooftop Units Electric Cooling with Electric Heat Option. 3 to 12.

Product Data. Features/Benefits. 50TFF Single-Package Rooftop Units Electric Cooling with Electric Heat Option. 3 to 12. Product Data 50TFF004-014 Single-Package Rooftop Units Electric Cooling with Electric Heat Option 3 to 12.5 Nominal Tons Standard-Efficiency Rooftop Units with: Pre-painted galvanized steel cabinet for

More information

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions PHH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE HEAT PUMP UNITS R 22, SINGLE PACKAGE ROOFTOP, 3 15 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency heat

More information

Models 542J, 548F, 549B, 549C SINGLE PACKAGE ROOFTOP

Models 542J, 548F, 549B, 549C SINGLE PACKAGE ROOFTOP COMMERCIAL Models 542J, 548F, 549B, 549C SINGLE PACKAGE ROOFTOP Sizes 024-180 STANDARD AND HIGH EFFICIENCY DuraPac and DuraPac Plus HEAT PUMP UNITS 2 to 15 Tons 50-1219 548F036-072 549B036-072 50-1304

More information

SINGLE PACKAGE ROOFTOP

SINGLE PACKAGE ROOFTOP COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS Model 580F The DuraPac Series Sizes 036-150 3 to 12 1 / 2 Tons 580F036-072 580F090-150 Standard-Efficiency Rooftop Units with: Exclusive

More information

BAC / BHC Product Specifications

BAC / BHC Product Specifications COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves

More information

Model 581B Sizes

Model 581B Sizes Bryant Air Conditioning COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEAT/ELECTRIC COOLING UNITS Model 581B Sizes 036-150 3to12 1 2Tons DESCRIPTION Unit 581B (Size 072 Shown) Unit 581B (Size 150 Shown) Specifically

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers / SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design

More information

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt)

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) PAH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency

More information

Product Data. S Pre-painted galvanized steel cabinet for long life and. S Commercial strength base rails with built-in rigging

Product Data. S Pre-painted galvanized steel cabinet for long life and. S Commercial strength base rails with built-in rigging 50HJQ004---016 50TFQ004---012 50HEQ003---006 Single --- Package Rooftop Standard and High Efficiency Heat Pump Units Product Data 50HJQ004-007, 50TFQ004-007, 50HEQ003-006 50HJQ008-012, 50TFQ008-012 50HJQ014-016

More information

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number *

Ashrae 90.1 EFFICIENCY PACKAGE A/C UNIT to 232 MBtuh. COOLING Rated Unit Model. Unit Dimensions Weight Number * COMMERCIAL PAE Product Specifications Ashrae 90. EFFICIENCY PACKAGE A/C UNIT - 80 to 232 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual,

More information

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP TONS (3 PHASE)

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP TONS (3 PHASE) PGS Product Specifications COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS / ELECTRIC UNIT R -22 SINGLE PACKAGE ROOFTOP -2 TONS ( PHASE) REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

Advance Product Data. Features/Benefits. 48HG HG Single Package Rooftop Units with ComfortLink Control / 2 to 25 Nominal Tons

Advance Product Data. Features/Benefits. 48HG HG Single Package Rooftop Units with ComfortLink Control / 2 to 25 Nominal Tons Advance Product Data 48HG014-028 50HG014-028 Single Package Rooftop Units with ComfortLink Control 12 1 / 2 to 25 Nominal Tons High Performance, Single Package Rooftop Units with: Cooling EERs up to 11.5

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE FAS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 241 models Two stage

More information

Product Data. Features/Benefits. 48TF Single-Package Rooftop Units Gas Heating/Electric Cooling. 3 to 12.5 Nominal Tons

Product Data. Features/Benefits. 48TF Single-Package Rooftop Units Gas Heating/Electric Cooling. 3 to 12.5 Nominal Tons Product Data 48TF004-014 Single-Package Rooftop Units Gas Heating/Electric Cooling 3 to 12.5 Nominal Tons 48TF004-007 48TF008-014 Standard-Efficiency Rooftop Units with: Exclusive integrated gas control

More information

COOLING, R 410A SINGLE PACKAGE ROOFTOP 5 10 TONS

COOLING, R 410A SINGLE PACKAGE ROOFTOP 5 10 TONS RAS Product Specifications ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 5 10 TONS (3 Phase 50 Hz) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency electric cooling with a low profile,

More information

Product Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 13 SEER Features/Benefits One-piece

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

38AUM Air Cooled Condensing Units 50Hz

38AUM Air Cooled Condensing Units 50Hz 38AUM Air Cooled Condensing Units 50Hz Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturer s Name: Saudi Airconditioning Manufacturing

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE RAS Product Specifications ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, 14 20 TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency electric

More information

Product Data. 40RUA/40RUS 6to30TonDirectExpansion 7.5to30TonChilledWater Packaged Air- Handling Units FEATURES/BENEFITS

Product Data. 40RUA/40RUS 6to30TonDirectExpansion 7.5to30TonChilledWater Packaged Air- Handling Units FEATURES/BENEFITS / 6toTonDirectExpansion 7.5toTonChilledWater Packaged Air- Handling Units Product Data 40RU07-40RU - C09035 C09036 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS GR4GN Series Single Packaged Gas/Electric Units GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units The GR4GN is designed specifically for retrofit applications and compatibility

More information

Product Data. Features/Benefits. 48TF Single-Package Rooftop Units Gas Heating/Electric Cooling. 3 to 12 1 / 2 Nominal Tons

Product Data. Features/Benefits. 48TF Single-Package Rooftop Units Gas Heating/Electric Cooling. 3 to 12 1 / 2 Nominal Tons Product Data 48TF004-014 Single-Package Rooftop Units Gas Heating/Electric Cooling 3 to 12 1 / 2 Nominal Tons 48TF004-007 48TF008-014 Standard-Efficiency Rooftop Units with: Exclusive integrated gas control

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units TECHNICAL SPECIFICATIONS GP4SN Series Single Packaged Electric Cooling Units P4SN 10.3 EER Commercial System 7½ and 10 Ton Units These 7½ and 10 ton units are designed specifically for retrofit applications

More information

Product Data. Features/Benefits. 38AK AKS with 40RM Commercial Air-Cooled Split Systems 50 Hz

Product Data. Features/Benefits. 38AK AKS with 40RM Commercial Air-Cooled Split Systems 50 Hz Product Data 38AK007-012 38AKS008-044 with 007-034 Commercial Air-Cooled Split Systems 50 Hz Nominal: 19.0 to 127.0 kw (5.3 to 35.8 Tons) 38AKS013-024 38AK007,008,012 38AKS008,009,012 Features/Benefits

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 150 models Terminal

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6-25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi--position design for horizontal or vertical installation without

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS/ELECTRIC UNIT R 22 SINGLE PACKAGE ROOFTOP TONS (3 Phase)

COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS/ELECTRIC UNIT R 22 SINGLE PACKAGE ROOFTOP TONS (3 Phase) PGS Product Specifications COMMERCIAL STANDARD EFFICIENCY PACKAGE GAS/ELECTRIC UNIT R 22 SINGLE PACKAGE ROOFTOP 6 12.5 TONS (3 Phase) REFRIGERATION CIRCUIT Scroll compressors on most models. High and low

More information

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS 07---25 SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz Product Data 07-12 16-25 C10887 Carrier s versatile packaged heat pump air-handling units satisfy design requirements

More information

50TC 50 Hz Packaged Rooftop Electric Cooling Units to 42.5 kw 5to12.5NominalTons. Product Data C the environmentally sound refrigerant

50TC 50 Hz Packaged Rooftop Electric Cooling Units to 42.5 kw 5to12.5NominalTons. Product Data C the environmentally sound refrigerant 50 Hz Packaged Rooftop Electric Cooling Units 18.17 to 42.5 kw 5to12.5NominalTons Product Data C08613 the environmentally sound refrigerant TABLE OF CONTENTS PAGE FURES AND BENEFITS... 3 MODEL NUMBER NOMENCLATURE...

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification

More information

Product Data KUWAIT SERIES

Product Data KUWAIT SERIES 50 Hz Packaged Rooftop Electric Cooling Units 18.17 to 34.0 kw 5to10Tons Product Data KUWAIT SERIES C08613 Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Product Data. 40RUA / 40RUS 6to30TonDirectExpansionwithPuron R Refrigerant 7.5to30TonChilledWater Packaged Air---Handling Units 60 Hz

Product Data. 40RUA / 40RUS 6to30TonDirectExpansionwithPuron R Refrigerant 7.5to30TonChilledWater Packaged Air---Handling Units 60 Hz / 6toTonDirectExpansionwithPuron R Refrigerant 7.5toTonChilledWater Packaged Air---Handling Units 60 Hz Product Data 07 --- 12 --- C09035 C09036 Carrier s versatile packaged air-handling units satisfy

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility

More information

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GN Series Single Packaged Gas/Electric Units with R-410A R6GN 10.8 EER Commercial System 12½ and 15 Ton Units These units offer flexibility in the replacement market. The 12½

More information

S/T Ratio. Input BTU/h

S/T Ratio. Input BTU/h SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

High Cap. (Btuh) HSPF COP

High Cap. (Btuh) HSPF COP RHS Product Specifications PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP 3 12.5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE R 410A HFC refrigerant ASHRAE 90.1 Energy Compliant

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16 SOUND REFRIGERANT ENVIRONMENTALLY Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE GAS / ELECTRIC, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT

More information

COMMERCIAL SINGLE PACKAGE ROOFTOP UNITS GAS HEATING/ELECTRIC COOLING UNITS

COMMERCIAL SINGLE PACKAGE ROOFTOP UNITS GAS HEATING/ELECTRIC COOLING UNITS COMMERCIAL SINGLE PACKAGE ROOFTOP UNITS GAS HEATING/ELECTRIC COOLING UNITS 580F, 579F, 581A/B/C DuraPac and DuraPac Plus Series Sizes 024-300 2 to 25 Tons 48-910df SIZES 024-073 50-1242f SIZES 090-151

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

Product Data. 50ZPA Single---Packaged Air Conditioner System 2 to 5 Nominal Tons ( )

Product Data. 50ZPA Single---Packaged Air Conditioner System 2 to 5 Nominal Tons ( ) Single---Packaged Air Conditioner System 2 to 5 Nominal Tons (024---060) Product Data Unit A05194 The unit is a packaged air conditioner for manufactured housing, residential, and light commercialapplications.

More information

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

PGE300 5 Year compressor limited warranty GAS HEATING RANGE. Heating

PGE300 5 Year compressor limited warranty GAS HEATING RANGE. Heating PGE Product Specifications COMMERCIAL ASHRAE EFFICIENT PACKAGE GAS HEATING/ELECTRIC COOLING R22 SINGLE PACKAGE ROOFTOP 6 25 TONS (3Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE Onepiece, high efficiency

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

Installation Instructions

Installation Instructions WEATHERMAKER 50AJ,AK,AW,AY020-060 Single Package Rooftop Units Electric Cooling with Electric Heat Option with Scroll Compressor and ComfortLink Controls 50/60 Hz Installation Instructions CONTENTS Page

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PPG2GI M1200 Product Line Single Packaged Gas/Electric Units 20 SEER, 81% AFUE 2-5 Ton Units Multi-Stage Cool / Two-Stage Heat The iq Drive gas/electric packaged system features

More information

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE RAS Product Specifications ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, 17.5 27.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, standard efficiency electric cooling

More information

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

RAS. Product Specifications. ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 15 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE

RAS. Product Specifications. ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 15 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE RAS Product Specifications ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 15 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE ASHRAE 90.1 energy compliant efficiency levels Single stage

More information

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS R6GI Series Single Packaged Gas/Electric Units 20 SEER 81% AFUE Multi-Stage Cool/Two-Stage Heat 2-5 Ton Single-Phase Units The iq Drive gas/electric packaged system features modulating

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

Product Data. 48HG HG Single Package Rooftop Units with ComfortLink Control / 2 to 25 Nominal Tons

Product Data. 48HG HG Single Package Rooftop Units with ComfortLink Control / 2 to 25 Nominal Tons Product Data 48HG014-028 50HG014-028 Single Package Rooftop Units with ComfortLink Control 12 1 / 2 to 25 Nominal Tons 48/50HG014-028 CENTURION UNIT Ultra High Performance, Single Package Rooftop Units

More information

RHS. Product Specifications. PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP TONS (1 & 3 Phase)

RHS. Product Specifications. PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP TONS (1 & 3 Phase) RHS Product Specifications PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP 3 12.5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, single packaged heat pump units that are

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling

More information

Product Data. 40RM/RMS Packaged Air-Handling Units 50/60 Hz 6 to 30 Nominal Tons (21 to 105 kw) 40RM007S-012S 40RMS008S-012S

Product Data. 40RM/RMS Packaged Air-Handling Units 50/60 Hz 6 to 30 Nominal Tons (21 to 105 kw) 40RM007S-012S 40RMS008S-012S /RMS Packaged Air-Handling Units 50/60 Hz 6 to 30 Nominal Tons (21 to 105 kw) Product Data S-012S SS-012S 014S-034S S014S-034S Features / Benefits Multiposition design can be installed horizontally or

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase COMMERCIAL SOUND REFRIGERANT ENVIRONMENTALLY PAD4 Product Specifications 14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/230 1 60 Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information