NEW ZEALAND GLULAM SPAN TABLES

Size: px
Start display at page:

Download "NEW ZEALAND GLULAM SPAN TABLES"

Transcription

1 NEW ZEALAND GLULAM SPAN TABLES The Glulam Span Tables have been developed primarily for domestic applications in accordance with NZS3603 Timber Structures Standard and with the joint AS/NZS 1328:1998 standard Glue Laminated Structural Timbers The purpose of these tables is to make it easier for builders, draughtsmen, architects and engineers to come up with a quick and accurate design for Glulam beams. These cover the most common domestic uses for Glulam beams roof beams, rafters, ridges, lintels and floor beams. At a glance designers and builders will be able to find the correct size of beams for a variety of spans at various spacings and loadings. Published New Zealand Pine Manufacturers Association 2008 Acknowledgement: Appreciation is extended to McIntosh Timber Laminates Ltd, Timberbond Industries (NZ) Ltd and Hunters (1998) Ltd for their assistance in the development of these tables. NZ Pine Manufacturers Association P.O. Box 3551 Richmond, Nelson (03) (03) info@pine.net.nz Page 1

2 STRUCTURAL CERTIFICATION : PRODUCER STATEMENT Producer Statement Glulam Span Tables The span tables and details in this brochure for glue laminated beams (Glulam) have been designed in accordance with sound and widely accepted engineering principles. The calculation and computation of these span tables was undertaken by Holmes Consulting Group Structural and Civil Engineers. The design properties of glue laminated timber in this brochure were determined in accordance with clauses 2.2 and C2.3 of NZS 3603: Timber Structures Standard. Laminated timber is a product certified by the Standards of New Zealand as being manufactured in accordance with the joint New Zealand/Australian Standard AS / NZS 1328:1998. Product should be obtained from manufacturers holding a current licence under the inspection scheme administered by the NZ Timber certification Board. The list of manufacturers licensed to AS/NZS Glue Laminated Structural Timbers is tabled on page 71 of this publication. Under this system all manufacturers are certified by the New Zealand Timber Certification Board, audited six-monthly and independently assessed and issued a licence number by Bureau Veritas. This process entitles approved manufacturers to display the S mark on all product. Product Liability for any loss incurred through non-performance would rest with the licenced manufacturer and the certifying authority. Structural design is in agreement with NZS 3603 (verification method B1 / VM1, 6.1 and NZS 4203 (Verification method B1 / VM1,2.2) with loads and deflection criteria as indicated on the tables. Seviceability and other criteria were selected using NZS 4203 (Verification method B1 / VM1,2.2), (Acceptable solution B1 / AS1,4.1). When installed in accordance with the specifications, details and limitations in this brochure, glue laminated timber members will comply with the requirements of the New Zealand Building Code. Disclaimer: While very effort has been made and all reasonable care taken to ensure the accuracy of the material contained herein, the Authors, Editors and Publishers of this Publication shall not be held to be liable or responsible in any way whatsoever and expressly disclaim any liability or responsibility for any loss damage costs or expenses howsoever incurred by any person whether the purchaser of this work or otherwise including but without in any way limiting any loss or damage costs or expenses incurred as a result of or in connection with the reliance whether whole or partial by any person as aforesaid upon any part of the contents of this publication. Should expert assistance be required, the services of a competent professional person should be sought Bruce Black National Manager Holmes Consulting Group The list of manufacturers licensed to AS/NZS Glue Laminated Structural Timbers is tabled on page 71 of this document. Under this system all manufacturers are certified by the New Zealand Timber Certification Board, audited six-monthly and independently assessed and issued a licence number by Bureau Veritas. This process entitles approved manufacturers to display the S mark on all product. Page 2

3 TABLE OF CONTENTS STRUCTURAL CERTIFICATION : PRODUCER STATEMENT... 2 INTRODUCTION SPECIFICATION DETAILS n STRUCTURAL GRADES... 6 n APPEARANCE GRADES... 6 n SERVICE CLASSES... 7 n TIMBER TREATMENT SPECIFICATION OPTIONS... 7 n PAINTING PROCEDURE... 7 ENGINEERING DESIGN PROPERTIES n BEAMS FULLY RESTRAINED ON COMPRESSION FLANGE GL n BEAMS FULLY RESTRAINED ON COMPRESSION FLANGE GL n BEAMS FULLY RESTRAINED ALONG TENSION FLANGE GL n BEAMS FULLY RESTRAINED ALONG TENSION FLANGE GL GLULAM SPAN TABLES n FLOOR BEAMS 1.5 kpa LIVE LOAD GL n FLOOR BEAMS 1.5 kpa LIVE LOAD GL n FLOOR BEAMS 2.0 kpa LIVE LOAD GL n FLOOR BEAMS 2.0 kpa LIVE LOAD GL n FLOOR BEAMS 3.0 kpa LIVE LOAD GL n FLOOR BEAMS 3.0 kpa LIVE LOAD GL n ROOF BEAMS - 3.0kPa LIVE LOAD GL n ROOF BEAMS, RAFTERS & RIDGES LIGHT ROOF n ROOF BEAMS, RAFTERS & RIDGES LIGHT ROOF MEDIUM WIND SPEED GL n ROOF BEAMS, RAFTERS & RIDGES LIGHT ROOF HIGH WIND SPEED GL n ROOF BEAMS, RAFTERS & RIDGES LIGHT ROOF - MEDIUM WIND SPEED GL n ROOF BEAMS, RAFTERS & RIDGES LIGHT ROOF HIGH WIND SPEED GL n ROOF BEAMS, RAFTERS & RIDGES HEAVY ROOF MEDIUM WIND SPEED GL n ROOF BEAMS, RAFTERS & RIDGES HEAVY ROOF - HIGH WIND SPEED GL n ROOF BEAMS, RAFTERS & RIDGES HEAVY ROOF MEDIUM WIND SPEED GL n ROOF BEAMS, RAFTERS & RIDGES HEAVY ROOF HIGH WIND SPEED GL n LINTELS SUPPORTING LIGHT ROOF & 1.5 kpa FLOOR GL n LINTELS SUPPORTING LIGHT ROOF & 1.5 kpa FLOOR GL n LINTELS SUPPORTING HEAVY ROOF & 1.5 kpa FLOOR GL n LINTELS SUPPORTING HEAVY ROOF & 1.5 kpa FLOOR GL n LINTELS SUPPORTING LIGHT ROOF & 2.0 kpa FLOOR GL n LINTELS SUPPORTING LIGHT ROOF & 2.0 kpa FLOOR GL n LINTELS SUPPORTING HEAVY ROOF & 2.0 kpa FLOOR GL n LINTELS SUPPORTING HEAVY ROOF & 2.0 kpa FLOOR GL n LINTELS SUPPORTING LIGHT ROOF & 3.0 kpa FLOOR GL n LINTELS SUPPORTING LIGHT ROOF & 3.0 kpa FLOOR GL n LINTELS SUPPORTING HEAVY ROOF & 3.0 kpa FLOOR GL n LINTELS SUPPORTING HEAVY ROOF & 3.0 kpa FLOOR GL n LINTELS SUPPORTING ROOF ONLY (LIGHT ROOF) GL n LINTELS SUPPORTING ROOF ONLY (LIGHT ROOF) GL n LINTELS SUPPORTING ROOF ONLY (HEAVY ROOF) GL n LINTELS SUPPORTING ROOF ONLY (HEAVY ROOF) GL n ROOF HIP MEMBERS GL n ROOF HIP MEMBERS GL n ROOF HIP MEMBERS PRECAMBERED BEAMS GL n ROOF HIP MEMBERS PRECAMBERED BEAMS GL n AUSTRALIAN STRUCTURAL LAMINATED BEAMS LIGHT ROOF GL n AUSTRALIAN STRUCTURAL LAMINATED BEAMS HEAVY ROOF GL QUESTION & ANSWERS MEMBERS LICENSED BY BUREAU VERITAS TO MANUFACTURE GLULAM Page 3

4 INTRODUCTION Glued laminated timber or Glulam is a strong, engineered, structural product, well proven in New Zealand building and construction for over 40 years and internationally for much longer. It was first used in 1893 to construct an auditorium in Basel, Switzerland. Now Glulam is gaining renewed popularity because of its many benefits to the designer, builder and end user. Ongoing research ensures that Glulam is designed to work better than ever in a host of construction applications. Increased design values have expanded design capabilities and improved performance. The new Bureau Veritas administered quality standards are internationally recognised and more performance based. This gives even greater assurance of long-term serviceability and performance meeting design. There are many reasons for using Glulam for your project from versatility to environmental reasons, to cost effectiveness. Unmatched versatility. Glulam has greater strength, stability and stiffness than dimensional timber and can be produced in uniform or varying depths to give strength where it is required. Lengths, dimensions and shapes can be produced almost without limit, making Glulam unsurpassed in its versatility. Appearance, aesthetics. Glue-laminated structural timber products are usually specified for the beauty as well as for strength. The natural aesthetic qualities of Glulam allow the structural elements of a building to be exposed for architectural effect. This combined with the natural warmth and timeless appeal of exposed timber make Glulam ideal for any application requiring an appealing and architecturally interesting structure. Lightweight. Weight for strength, a Glulam beam is stronger than both steel and concrete. This means that The solution for large open spaces is found in the strength and simplicity of Glulam roof frames. Three-story post and beam structure creates a unique feature demonstrating timber s natural strength and design possibilities. Glulam beams can span very long distances with minimal intermediate support required. Dependent upon specific loading conditions a steel beam may be 20% heavier and a reinforced concrete beam 600% heavier than an equivalent Glulam beam for carrying the same load. The resulting lighter structure can lead to significant economies in foundation construction. Consistency of Performance. The process of glue laminating timber eliminates the natural performance variations that characterise solid sawn timber. As Glulam beams are engineered wood products that are manufactured to meet specific performance criteria, the specifier and user can be assured that Glulam products will consistently perform as expected. Ease of installation. When it comes to installation existing, traditional skills can be used and builders who are confident in working with timber easily handle Glulam products. Other sub trades find timber easier and quicker to connect to. As a consequence, erection times are significantly reduced in Glulam structures. Environment. Glulam uses the World s most prolific renewable construction material. In Canada and New Zealand (where Pinus Radiata grows fastest), trees are growing faster than they are being consumed to build houses and the available plantation pine is increasing dramatically. For their load carrying capability, Glulam beams are very efficient to produce. The energy required to produce a glue-laminated beam from the log is only a fraction of the energy required to produce steel from ore or concrete from limestone. Using Glulam in fact contributes to a positive storage of carbon compared to the large amount of carbon emission resulting from the production of steel. All round, the production of Glulam has the least effect on the environment by far. Page 4

5 INTRODUCTION Fire resistance. When exposed to the heat of a fire, timber undergoes a thermal breakdown (pyrolysis) into combustible gases, and a layer of charcoal forms on the burning surface. Glue laminated timber burns slowly and at a predictable rate, and as such fire design techniques can be relatively easily applied. When large cross-sections are subjected to a fire a char forms around the outside of the beam that protects the core by restricting the oxygen supply. There have been examples of portal frame buildings that have effectively burnt down leaving only the charred portal frame. The portal frames were then cleaned and, after engineers inspection, the structure rebuilt on the existing Glulam. Harsh environments. Timber is naturally resilient to attack by corrosive atmospheres that would normally cause rust. With appropriate treatment Glulam members will completely avoid deterioration and require minimal long-term maintenance. This makes Glulam structural members suited to environments exposed to corrosive or highhumidity atmospheres. Pre-cambering. Often deflection is a controlling restraint in structural beam design, especially in longer spans. Whilst any structural member can be designed to minimise deflection, Glulam is the only engineered wood product that can easily be precambered to eliminate the aesthetic effect of in-service deflections. Curved Glulam portals highlight the design flexibility and natural beauty timber can bring in an indoor outdoor situation. Shock Resistance. Wood, steel, and concrete are the three principal materials utilised by civil engineers when designing structures. Unlike steel and concrete, which are cast and formed, wood is anisotropic by nature meaning it performs differently in different directions. Wood also has excellent thermal, acoustic and electrical insulating properties. These factors make it very resilient, naturally. This resilience is a great advantage and permits it to absorb seismic and wind shocks that would actually cause failure in other materials. Selected Timber Species: Glulam beams are commonly produced in New Zealand from the species Pinus Radiata and Douglas Fir. Occasionally species such as Macrocarpa and Lawson s Cyprus are also used. All of these species are suitable for structural glue laminated timber products. More exotic species can also be used with success. Species such as Jarrah, Cedar or Eucalyptus Saligna. Almost any timber species that can be kiln dried can be used in Glulam. However, be aware that different timber species will have varying characteristic strengths and the resulting Elastic Moduli of the Glulam will vary accordingly. Speak to a licensed Glulam manufacturer for more assistance on this subject. The clean lines and cranked shape of these pitched Glulam rafters illustrate the versatile roof forms possible using laminated timber. Page 5

6 SPECIFICATION DETAILS STRUCTURAL GRADES There are a range of structural grades of glue laminated timber beams produced in New Zealand in accordance with Standard AS/NZS These grades were developed by the Australian and New Zealand industries to assist designers and specifiers in the selection of Glulam members and their associated design properties. The following table of structural grade characteristics is referenced from AS/NZS 1328 part 2. Characteristic Strengths and Elastic Moduli for Glulam Grades Characteristic Strengths (MPa) Elastic Moduli (MPa) GL Grade Bending Tension parallel to grain Shear in Beam Compression parallel to grain Short modulus of elasticity parallel to the end grain Short duration modulus of rigidity for beams GL GL GL Note: All tables in this reference guide are based upon characteristics of Glulam meeting GL8 and GL10 grades. For references for higher grades than GL8 and GL10 as incorporated in these Span Tables please refer to a qualified producer. There is a list of qualified producers in the index at the back of this publication. Higher grades (i.e. GL12, etc) will give greater span and load carrying capability than GL8 and GL10 for the same section size. APPEARANCE GRADES There are three standard finishing grades that may be specified, as defined in AS/NZS 1328 part 1. The appearance grades relate to the aesthetic appearance of the visible surfaces of the glued laminated members. This classification bears no relationship to the structural performance of the timber. Definition of Appearance Grades Appearance Grade A Description This grade is intended for use in applications where appearance of the member is important and clear or painted finishes are used. All surface voids are filled or repaired. Unless it is specified otherwise, the surfaces shall be sanded to a minimum of 60-grit finish. B The grade is intended for use in painted applications where appearance is important but a planed finish is acceptable. The machining shall conform to No. 2 dressed surfaces grade as defined in AS Occasional skips in the surface are permissible and minor blemishes, voids and machining want shall be acceptable. The outer-most laminations shall be free of loose knots and voids. C This grade is intended for use in applications where appearance is not important. All blemishes and voids are acceptable. Note: The Appearance Grades most commonly produced in New Zealand are Grades A and B. Page 6

7 SPECIFICATION DETAILS SERVICE CLASSES The Service Class defines the environmental conditions in which glue laminated beams may be used. There are three service classes defined as shown in the following table. Definition of Environmental Conditions for Glulam Service Classes Service Class Description Environmental Conditions 1 Interior Service Class characterised by moisture content in the materials corresponding to a temperature of 20 C and relative humidity of the surrounding air only exceeding 65% for a few weeks per year. For example: Domestic Houses, Commercial Offices. 2 Exterior, under cover Service Class characterised by moisture content in the materials corresponding to a temperature of 20 C and relative humidity of the surrounding air only exceeding 85% for a few weeks per year. For example: Open sheds, exposed beams under soffits, porches, wool scouring plants, laundries. 3 Exterior, fully exposed Service Class characterised by climatic conditions leading to higher moisture content than Service Class 2, or where timber is directly exposed to sun and/or rain. For example: Marine structures, bridges. TIMBER TREATMENT SPECIFICATION OPTIONS In order to meet the Services Classes outlined above, depending on where the Glulam structure is to be used, specifiers will need to select timber treatment levels based on one of the following: Hazard Class H1 H2 H3 H4 H5 H6 End Use Low decay hazard Slight risk of decay and risk of termite attack Moderate decay hazard High decay hazard Severe decay hazard Marine hazard Timber treatment options can be either CCA treatment (the requirement for H5 or H6 is rare and specific situations should be discussed with the manufacturer) or LOSP (up to H3). LOSP is an envelope treatment, and because of this, care must be taken when cutting or drilling post-treatment that the affected area is recoated with a suitable protective coating. PAINTING PROCEDURE If Glulam has been pre-primed, the protective coating primer may tend to deteriorate over a period of time and become slightly chalky unable to bond adequately to any additional coating systems without some preparation work. A simple way of testing whether there has been any deterioration is to cut a small x through the existing coating system with a sharp blade. Press some cellulose sticky tape firmly across the cut and then rip off the tape. If any of the coating comes off with the tape then the primer is not adequately sound and must be removed by sanding. Sand back until the surface is completely free from all dirt and degraded material and dust off. Prime all surfaces, paying particular attention to cut ends and joints, with a good quality solventbased alkyd primer. Water based primers are less effective in this application. Allow to dry as per the manufacturers instructions and lightly sand to an even finish. Apply two coats of premium brand acrylic exterior grade top coat to the manufacturers recommendations. Page 7

8 ENGINEERING DESIGN PROPERTIES BEAMS FULLY RESTRAINED ON COMPRESSION FLANGE GL8 Glulam Grade = GL8 k1 = 0.8 SLS Deflection Limit = Span / 400 Section Size dxb (mm) Area A (mm 2 ) 135 x x x x x x x x x x x Section Moment of Modulus Z Inertia I V n Span (m) (10 3 mm 3 ) (10 6 mm 4 ) x x x x x x x x x (knm) - ULS, w (ULS) (kn/m) & w (SLS,k 2 =1.5) (kn/m) giving deflection = SLS Deflection Limit for Span (Note in both cases w is limited where necessary to prevent shear failure for the span) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) Page 8

9 ENGINEERING DESIGN PROPERTIES BEAMS FULLY RESTRAINED ON COMPRESSION FLANGE Continued GL8 Glulam Grade = GL8 k1 = 0.8 SLS Deflection Limit = Span / 400 Section Size dxb (mm) Area A (mm 2 ) Section Modulus Z (10 3 mm 3 ) Moment of Inertia I (10 6 mm 4 ) V n 135 x x x x x x x x x x x x x x x x x x x x Span (m) (knm) - ULS, w (ULS) (kn/m) & w (SLS,k 2 =1.5) (kn/m) giving deflection = SLS Deflection Limit for Span (Note in both cases w is limited where necessary to prevent shear failure for the span) w (ULS) 0.6 w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) Page 9

10 ENGINEERING DESIGN PROPERTIES BEAMS FULLY RESTRAINED ON COMPRESSION FLANGE GL10 Glulam Grade GL10 k = 0.8 SLS Deflection Limit = Span/ 400 Section Moment of!m (knm) - ULS, w (ULS) (kn/m) & w (SLS,k =1.5) (kn/m) giving deflection = SLS Deflection Limit for Span (Note in both cases w is limited where necessary to prevent shear failure for the span) Section Size Area A Modulus Z Inertia I Span (m) dxb (mm) (mm²) (10 mm³) (10 mm )!V !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) !M x w (ULS) w (SLS) Page 10

11 ENGINEERING DESIGN PROPERTIES BEAMS FULLY RESTRAINED ON COMPRESSION FLANGE GL10 Continued Section Size dxb (mm) Glulam Grade GL10 k = 0.8 SLS Deflection Limit = Span/ 400 Area A (mm²) Section Modulus Z (10 mm³) Moment of Inertia I (10 mm ) x x x x x x x x x x !V ( L ) ( L ) ( L ) ( L ) ( L ) ( L ) ( L ) ( L ) ( L ) ( L ) !M (knm) - ULS, w (ULS) (kn/m) & w (SLS,k =1.5) (kn/m) giving deflection = SLS Deflection Limit for Span (Note in both cases w is limited where necessary to prevent shear failure for the span) Span (m) !M w U S w (SLS) !M w U S w (SLS) !M w U S w (SLS) !M w U S w (SLS) !M w U S w (SLS) !M w U S w (SLS) !M w U S w (SLS) !M w U S w (SLS) !M w U S w (SLS) !M w U S w (SLS) Page 11

12 ENGINEERING DESIGN PROPERTIES BEAMS FULLY RESTRAINED ALONG TENSION FLANGE GL8 Glulam Grade = GL8 k1 = 0.8 SLS Deflection Limit = Span / 400 Section Size dxb (mm) Area A (mm 2 ) 135 x x x x x x x x x x Section Modulus Z (10 3 mm 3 ) Moment of Inertia I (10 6 mm 4 ) V n x x x x x x x x x Span (m) (knm) - ULS, w (ULS) (kn/m) & w (SLS,k 2 =1.5) (kn/m) giving deflection = SLS Deflection Limit for Span w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) Page 12

13 ENGINEERING DESIGN PROPERTIES BEAMS FULLY RESTRAINED ALONG TENSION FLANGE Continued GL8 Glulam Grade = GL8 k1 = 0.8 SLS Deflection Limit = Span / 400 Section Size dxb (mm) Area A (mm 2 ) Section Modulus Z (10 3 mm 3 ) Moment of Inertia I (10 6 mm 4 ) V n 135 x x x x x x x x x x x x x x x x x x x Span (m) (knm) - ULS, w (ULS) (kn/m) & w (SLS,k 2 =1.5) (kn/m) giving deflection = SLS Deflection Limit for Span w (ULS) 0.6 w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) w (ULS) w (SLS) Page 13

14 ENGINEERING DESIGN PROPERTIES BEAMS FULLY RESTRAINED ALONG TENSION FLANGE GL10 Glulam Grade GL10 k = 0.8 SLS Deflection Limit = Span/ 400 Section Size dxb (mm) Area A (mm²) Section Modulus Z (10 mm³) Moment of Inertia I (10 mm ) 270 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x !V Span (m)!m (knm) - ULS, w (ULS) (kn/m) & w (SLS,k =1.5) (kn/m) giving deflection = SLS Deflection Limit for Span (Note in both cases w is limited where necessary to prevent shear failure for the span) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) !M w (ULS) w (SLS) Page 14

INDEX OF W.T.I. BEAMS

INDEX OF W.T.I. BEAMS INDEX OF W.T.I. BEAMS Contents Beam Type Page General Specification 3-7 Roof Construction Mass 8-9 Engineers Certification 10 Rafters Roof Load of Light Sheet (10kg/m2) 13 Single & Continuous Span Roof

More information

Meypine. Handy Span Guide

Meypine. Handy Span Guide Handy Span Guide and are H3 preservative treated pre-primed timbers manufactured from sustainably grown plantation softwoods. They are available in both structural and nonstructural sections, with this

More information

01 CONTENTS. e-beam. e-beam. Technical Information 03

01 CONTENTS. e-beam. e-beam. Technical Information 03 B 1 01 CONTENTS 02 e-beam Technical Information 03 11 e-beam Strutting Beams 12 Strutting Counter Beams 14 Strutting Hanging Beams 16 Counter Beams 18 Roof Beams 20 ENGINEERED TO LOAD ENGINEERED TO LENGTH

More information

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N DESIGN GUIDE PURLINS AND GIRTS ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS S&T029N JUL 2015 CONTENTS INTRODUCTION 2 Acknowledgements 2 Disclaimer 2 Product Technical Statement 3 Producer Statement

More information

Rosboro TM. Next-Generation Glulam. n Architectural Appearance. n Full Framing-Width Stock. Glulam. n I-Joist and Conventional.

Rosboro TM. Next-Generation Glulam. n Architectural Appearance. n Full Framing-Width Stock. Glulam. n I-Joist and Conventional. n Architectural Appearance n Full Framing-Width Stock Glulam n I-Joist and Conventional Depths 2 X-Beam: X-Beam is the building industry s first full framing-width stock glulam in architectural appearance.

More information

1¾" BEAMS & HEADERS. [1¾" THICKNESS] NER F b E Design Values LAMINATED VENEER LUMBER. Finnforest USA, Engineered Wood Division

1¾ BEAMS & HEADERS. [1¾ THICKNESS] NER F b E Design Values LAMINATED VENEER LUMBER. Finnforest USA, Engineered Wood Division LAMINATED VENEER LUMBER 1¾" BEAMS & HEADERS [1¾" THICKNESS] NER-555 2900 F b - 2.0 E Design Values Finnforest USA, Engineered Wood Division 32205 Little Mack Avenue Roseville, Michigan 48066 Phone: 800/622-5850

More information

Span guide for residential framing. September Fully supported by

Span guide for residential framing. September Fully supported by Span guide for residential framing September 2011 Fully supported by Engineered to perform Structural LVL is engineered for reliable performance and is available in two complementary ranges. and + are

More information

BOISE GLULAM Beam and Column Specifier Guide

BOISE GLULAM Beam and Column Specifier Guide BOISE GLULAM Beam and Column Specifier Guide WEBGLUSPEC 02/28/2013 2... Just ask for BOISE GLULAM beams Glued laminated timbers from Boise Cascade Engineered Wood Products add functional beauty to any

More information

Formwork Solutions Guide

Formwork Solutions Guide Formwork Solutions Guide truform Trust truform truform is structural Laminated Veneer Lumber (LVL) specially manufactured for use in structural concrete formwork applications. It is manufactured in a controlled

More information

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2.

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2. GP Lam LVL GP Lam LVL Introduction.....................32 Bearing Details...................34 Handling and Installation..........35 Floor Beams.....................35 Window, Patio Door and Garage Door

More information

SHAPING THE FUTURE OF FORMWORK SHAPING THE FUTURE OF FORMWORK

SHAPING THE FUTURE OF FORMWORK SHAPING THE FUTURE OF FORMWORK SHAPING THE FUTURE OF FORMWORK SHAPING THE FUTURE OF FORMWORK Truform - Description and purpose 1 Truform is structural laminated veneer lumber (LVL) intended for use as concrete formwork beams bearers,

More information

Design principles and Assumptions

Design principles and Assumptions Design principles and Assumptions The design and use of concrete slabs that utilise ARMOURDECK 300 in composite construction may be carried out using either: the relevant Australian and international Standards

More information

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2.

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2. GP Lam LVL Grade Thickness Depth 2.0E 1 3 49, 3 1 29 7 1 49, 9 1 49, 9 1 29, 11 1 49, 11 7 89, 149, 169, 189, 249 (209and 229 by special order) 1.5E 1 3 49 7 1 49, 9 1 49, 9 1 29, 11 1 49, 11 7 89, 149,

More information

Allowable Holes in VERSA-LAM Beams

Allowable Holes in VERSA-LAM Beams VERSA-LAM Products 23 An Introduction to VERSA-LAM Products When you specify VERSA-LAM laminated veneer headers/beams, you are building quality into your design. They are excel lent as floor and roof framing

More information

Rosboro Manufactured Timber. Preferred lengths Dry stable timber Full-Framing Width

Rosboro Manufactured Timber. Preferred lengths Dry stable timber Full-Framing Width Rosboro Manufactured Timber n n n Preferred lengths Dry stable timber Full-Framing Width TABLE OF CONTENTS Available s 2 Beam, Header and Column Design Values 3 Allowable Uniform Floor Loads 4 Allowable

More information

TRUS JOIST BEAMS, HEADERS, AND COLUMNS

TRUS JOIST BEAMS, HEADERS, AND COLUMNS FLOOR SOLUTIONS ROOF SOLUTIONS TRUS JOIST BEAMS, HEADERS, AND COLUMNS Featuring TimberStrand LSL, Microllam LVL, and Parallam PSL Uniform and Predictable Minimal Bowing, Twisting, and Shrinking Strong

More information

BOISE GLULAM 24F-V4 IJC

BOISE GLULAM 24F-V4 IJC Engineered Wood Products 24F-V4 IJC I-Joist Compatible Glulam Guide 3½" x 7½" 3½" x 9½" 3½" x 11⅞" 3½" x 14" 3½" x 16" Sizes Available 5½" x 7½" 5½" x 9½" 5½" x 11⅞" 5½" x 14" 5½" x 16" IJG 01/2010 2 I-Joist

More information

Anthony Glulam Advantages

Anthony Glulam Advantages GLULAM Table of Contents Glulam Advantages...1 About Us...2 Anthony Power Products Family...3 Design Properties...4-5 V4 1.7E IJC Framing Load Tables...-8 V4 1.7E Stock Depth Industrial Load Tables...-17

More information

JD3 rated for greater connection strength. makes it easy to spot in the warehouse or on site

JD3 rated for greater connection strength. makes it easy to spot in the warehouse or on site JD3 rated for greater connection strength H2S termite treated Distinctive blue colour makes it easy to spot in the warehouse or on site Made in Australia Wesbeam Span Tables Roof Members Rafters 4 Roof

More information

GP Lam LVL. (20!and 22! by special order) 13 4! 31 2! 1.5E. Lengths: up to 60 feet. Referenced dimensions are nominal and used for design purposes.

GP Lam LVL. (20!and 22! by special order) 13 4! 31 2! 1.5E. Lengths: up to 60 feet. Referenced dimensions are nominal and used for design purposes. GP Lam LVL Grade 2.0E 1.5E Thickness Depth 13 4!, 31 2! 7 4!, 9 4!, 9 2!, 11 4!, 117 8!, 14!, 16!, 18!, 24! (20!and 22! by special order) 13 4! 7 1 4!, 9 1 4!, 9 1 2!, 111 4!, 117 8!, 14!, 16! 31 2! 45

More information

LINTELS WITH TG. Single Spans. Lintels Supporting Truncated Girder Truss INCLUDES TG Set Back 2.4m Maximum 40 kg/m 2 90 kg/m 2

LINTELS WITH TG. Single Spans. Lintels Supporting Truncated Girder Truss INCLUDES TG Set Back 2.4m Maximum 40 kg/m 2 90 kg/m 2 63 Single Spans INCLUDES TG Set Back 2.4m Maximum 40 kg/m 2 90 kg/m 2 TG Set Back 3.6m Maximum 40 kg/m 2 90 kg/m 2 Restraint value for slenderness calculations is 600 mm. K6 factor of 1.0 used. K23 factor

More information

western for products manufactured in White City, Oregon

western for products manufactured in White City, Oregon western VERSA-LAM SPECIFIER Guide for products manufactured in White City, Oregon Western VERSA-LAM Guide 11/29/2012 2 VERSA-LAM Products An Introduction to VERSA-LAM Products When you specify VERSA-LAM

More information

SmartFrame Product Warranty*

SmartFrame Product Warranty* SCOPE OF THIS PUBLICATION This Design Guide and load Tables assist in the selection of SmartLam GL17 beams for most of the common structural arrangements met in sheet construction. Methods of developing

More information

Technical Data Sheet Timber Decks Commercial, Industrial & Marine 7

Technical Data Sheet Timber Decks Commercial, Industrial & Marine 7 Recommended Practice / February 2004 Introduction Timbers natural appeal, strength and environmental credentials continue to make it the ideal choice for decking in commercial, industrial and marine structures,

More information

Product grading of all members is compliant with AS1720: Timber Structures.

Product grading of all members is compliant with AS1720: Timber Structures. Finger Jointed Treated Pine Span Tables SPAN TABLES These span tables have been developed in accordance with the relevant Australian Standards, however please check for state and local government variations.

More information

2.0E ES LVL U.S. Design Manual

2.0E ES LVL U.S. Design Manual I N T E R N A T I O N A L B E A M S 2.0E ES LVL U.S. Design Manual August 2013 2 INTERNATIONAL BEAMS, INC. Our Company At International Beams, Inc. we take pride in providing our customers with premium

More information

PLANK-AND-BEAM FRAMING FOR RESIDENTIAL BUILDINGS

PLANK-AND-BEAM FRAMING FOR RESIDENTIAL BUILDINGS PLANK-AND-BAM FRAMING FOR RSIDNTIAL BUILDINGS American Wood Council 4 Wood Construction Data American Forest & Paper Association The American Wood Council (AWC) is the wood products division of the American

More information

SmartLam GL18 Design Guide

SmartLam GL18 Design Guide SmartLam GL18 Design Guide A BOND ADHESIVE STRAIGHT AND TRUE 18 GlueLam STRONG ENGINEERED MECHANICALLY GRADED LAMINATES SCOPE OF THIS PUBLICATION This Design Guide and Load Tables assist in the selection

More information

SPAN TABLES FOR RESIDENTIAL BUILDING NOW AVAILABLE H2-S TREATED TO PROTECT AGAINST TERMITES

SPAN TABLES FOR RESIDENTIAL BUILDING NOW AVAILABLE H2-S TREATED TO PROTECT AGAINST TERMITES SPAN TABLES FOR RESIDENTIAL BUILDING NOW AVAILABLE H2-S TREATED TO PROTECT AGAINST TERMITES contents Contents Introduction Page Nº Application 3 Some information about Hyspan and its use _ 3 Terminology

More information

LVL User s Guide. Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems

LVL User s Guide. Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems LVL User s Guide Technical Data for LVL Headers, Beams, Column Applications for Residential Floor and Roof Systems U N I T E D S T A T E S V E R S I O N Quality Products Committed Service O U R H I S TO

More information

Prolam LVL 15 Design Guide. Register Free for our Beam Calculator

Prolam LVL 15 Design Guide. Register Free for our Beam Calculator Prolam LVL 15 Design Guide Register Free for our Beam Calculator www.prolamnz.com/specifiers 2 Contents 03 Scope of Publication 04 Prolam LVL 15 05 Design/Effective Span 06 Continuous Spans 06 Rip Sawing

More information

GENERAL INFORMATION FEATURES.

GENERAL INFORMATION FEATURES. TECHNICAL GUIDE GENERAL INFORMATION SUPERIOR ENGINEERED JOIST SYSTEMS JoistRite is a specially designed, patented, cold-formed steel section that has one of the highest strength-to-mass ratios of any structural

More information

RAFTERS. Single and Continuous Spans

RAFTERS. Single and Continuous Spans 7 Single and Continuous Spans Restraint value for slenderness calculations is 1200 mm, in 10, 20, 40( kg/m 2 ) (Restraint may be by Roof Battens) Restraint value for slenderness calculations is 600 mm,

More information

Requirements for Use of Allowable Load Tables

Requirements for Use of Allowable Load Tables Southern Pine Allowable Load Tables Requirements for Use of Allowable Load Tables 1. These tables are for gravity loads only. Consult a registered design professional for wind and seismic load analysis

More information

SmartLVL 18 Design Guide

SmartLVL 18 Design Guide SmartLVL 18 LVL 18 Design Guide TREATABLE SUSTAINABLE STRONGER UP TO 6M LENGTHS CONSISTENCY F27 COMPATIBLE Edition 1 2011 SCOPE OF THIS PUBLICATION This Design Guide and Load Tables assist in the selection

More information

SPAN TABLES SPAN TABLES

SPAN TABLES SPAN TABLES SPAN TABLES SPAN TABLES - These span tables have been developed in good faith, with the assistance of Mr.Peter Falvey B.E., M.I.E.Aust., C.P.Eng., R.P.E.Q.(579) in accordance with the relevant Australian

More information

DURAPLATE. Advanced composite panels for diverse applications.

DURAPLATE. Advanced composite panels for diverse applications. DURAPLATE Advanced composite panels for diverse applications. Advanced Composite Technology for Next-Level Product Performance Unmatched Durability, Increased Strength And Improved Appearance DuraPlate,

More information

Purlins and Girts. A division of Canam Group

Purlins and Girts. A division of Canam Group Purlins and Girts A division of Canam Group TABLE OF CONTENTS OUR SOLUTIONS AND SERVICES............................................................ 5 Cautionary statement..................................................................

More information

Strutting Beams Supporting Underpurlins Only

Strutting Beams Supporting Underpurlins Only Strutting Beams Supporting Underpurlins Only fan struts strutting beam roof area supported by strutting beam = L/2 x B/2 block underpurlin strutting beam strut L = total rafter span strutting beam span

More information

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association Maximum Span Tables for Joists and Rafters MSR Lumber for Performance Figure provided courtesy of the American Forest & Paper Association 2 MSRLumber Producers Council Span Tables Purpose and Introduction

More information

Structurlam Mass Timber Corporation Revised October 11, 2018

Structurlam Mass Timber Corporation Revised October 11, 2018 Structurlam CrossLam PR-L314C Structurlam Mass Timber Corporation Revised October 11, 2018 Products: Structurlam CrossLam Cross-Laminated Timber Structurlam Mass Timber Corporation 2176 Government Street

More information

2. Runway & Crane System

2. Runway & Crane System 2. Runway & Crane System The crane runway girders, crane, columns and building frames can all be regarded as components of the overall crane installation. The individual components cannot be designed in

More information

TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND TIMBER DECKS

TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND TIMBER DECKS TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND TIMBER DECKS COMMERCIAL, INDUSTRIAL & MARINE 7 RECOMMENDED PRACTICE // AUGUST 07 Timber s natural appeal, strength and environmental credentials continue

More information

WARRANTY AND LIMITATIONS

WARRANTY AND LIMITATIONS 2 GENERAL INFORMATION QUALITY AND SERVICE COUNT Marino\Ware is proud to present this catalog that details our Lightweight Steel Framing Products. For over 70 years, Marino\Ware has been providing their

More information

Plate Girder and Stiffener

Plate Girder and Stiffener Plate Girder and Stiffener (Gelagar Pelat dan Pengaku) Dr. AZ Department of Civil Engineering Brawijaya University Introduction These girders are usually fabricated from welded plates and thus are called

More information

LP SolidStart Engineered Wood Products

LP SolidStart Engineered Wood Products LP SolidStart Engineered Wood Products Technical Guide for Residential Floors and Roofs Featuring LP SolidStart IJoists LP SolidStart LVL LP SolidStart LSL LP SolidStart Rim Board Please verify availability

More information

Safety factor and fatigue life effective design measures

Safety factor and fatigue life effective design measures Safety factor and fatigue life effective design measures Many catastrophic failures have resulted from underestimation of design safety and/or fatigue of structures. Failure examples of engineered structures

More information

PIPINGSOLUTIONS, INC.

PIPINGSOLUTIONS, INC. Piping Stress Analysis Where do I start? The following information will take you step-by-step through the logic of the data collection effort that should occur prior to beginning to model a piping system

More information

Elcometer 506 Pull- Off Adhesion Gauge. elcometer.com 1

Elcometer 506 Pull- Off Adhesion Gauge. elcometer.com 1 Elcometer 506 Pull- Off Adhesion Gauge elcometer.com 1 Elcometer 506 STANDARDS: ASTM D4541, ASTM D7234, AS/NZS 1580.408.5, BS 1881-207, DIN 1048-2, EN 12636, EN 13144, EN 1542, EN 24624, ISO 16276-1, ISO

More information

Heavy Vehicle Visibility

Heavy Vehicle Visibility Heavy Vehicle Visibility Industry Technical Council Advisory Procedure Printed by 3M Traffic Safety Systems in the interest of improving truck safety, through greater visibility Disclaimers This Code of

More information

Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts

Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts MATERIALS Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts Authors: Kevin Cowie, Alistair Fussell Affiliation: Steel Construction New Zealand Inc. Date: 20 th February 2018 Ref.:

More information

Bending strength, density and modulus of elasticity of BauBuche laminated veneer lumber in comparison with other materials.

Bending strength, density and modulus of elasticity of BauBuche laminated veneer lumber in comparison with other materials. BauBuche Efficiency 07-14 - EN Sheet 4 / 19 Bending strength, density and modulus of elasticity of BauBuche laminated veneer lumber in comparison with other materials. N/mm 2 kg/m 3 N/mm 2 70 48 28 120

More information

American Institute of Timber Construction 7012 South Revere Parkway, Suite 140, Centennial, CO

American Institute of Timber Construction 7012 South Revere Parkway, Suite 140, Centennial, CO American Institute of Timber Construction 7012 South Revere Parkway, Suite 140, Centennial, CO 80112-5092 303-792-9559 AITC 117-2004 STANDARD SPECIFICATIONS FOR STRUCTURAL GLUED LAMINATED TIMBER OF SOFTWOOD

More information

Elcometer 506 Pull- Off Adhesion Gauge. Product Brochure/Flyer. 506 PAT Adhesion Tester

Elcometer 506 Pull- Off Adhesion Gauge. Product Brochure/Flyer. 506 PAT Adhesion Tester Product Brochure/Flyer Elcometer 506 Pull- Off Adhesion Gauge elcometer.com 1 Copyright 2016 Burwell Technologies For more information: 1300 287 935 / mail@burwell.com.au / www.burwell.com.au Elcometer

More information

Innovations. Supplement to Eldon Product Catalogue

Innovations. Supplement to Eldon Product Catalogue Innovations Supplement to Eldon Product Catalogue Table of contents Quick fixation baying brackets... 4 Mounting plate brackets... 6 Profile system... 8 Side panel improvement... 10 Easy fixation with

More information

Safety and Installation Instructions

Safety and Installation Instructions Safety and Installation Instructions This document applies to the following UL-listed Gloria Solar Standard Modules: GSM6- series GSS6- series Rev: 1.2 Release Date: September 03, 2009 Gloria Solar Co.,

More information

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard A manufacturer s view of bushing reliability, testing and analysis By Lars Jonsson Håkan Rudegard 1 A manufacturer s view of bushing reliability, testing and analysis Lars Jonsson Håkan Rudegard ABB Sweden

More information

U.S. PATENT NO.: US 7,765,771 TECHNICAL GUIDE SUPERIOR ENGINEERED FLOOR FRAMING SYSTEM

U.S. PATENT NO.: US 7,765,771 TECHNICAL GUIDE SUPERIOR ENGINEERED FLOOR FRAMING SYSTEM U.S. PATENT NO.: US 7,765,771 TECHNICAL GUIDE SUPERIOR ENGINEERED FLOOR FRAMING SYSTEM SUPERIOR ENGINEERED JOIST SYSTEMS JoistRite is a specially designed, patented, cold-formed steel section that has

More information

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS

Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS Quality by Design CAPACITIES FROM 75,000 TO OVER 750,000 BUSHELS VARIETY OF PEAK LOAD RATINGS LARGE ROOF DECKS For nearly 80 years Behlen Mfg. Co. has focused on meeting customer needs. This is done with

More information

SmartLam GL 17 Design Guide

SmartLam GL 17 Design Guide 2017 SmartLam GL 17 Design Guide Edition 1 Table of contents Scope of this publication Introduction 1 GLTAA deflection limits 1 Ordering SmartLam GL 17 2 Installation - Preparatory work - Deflection -

More information

1 TAMCO ALUMINUM CONTROL DAMPER Installation Guidelines For Series 1000, 1400, 1500, 9000, 9000 BF FOR TAMCO JACK SHAFTS REFER TO INSTRUCTIONS PROVIDED IN PARTS BOX. FOR TAMCO JUMPERS REFER TO INSTRUCTIONS

More information

CV/LF and CV/CF. TICO Structural Bearings

CV/LF and CV/CF. TICO Structural Bearings CV/LF and CV/CF TICO Structural Bearings TICO CV/LF and TICO CV/CF Isolation of vibrations from one part of a building to another is as equally important as isolating the whole building itself. Indeed,

More information

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * PRODUCT: Heavy Duty Stock Car Steel Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

ELASTOMERIC ISOLATORS

ELASTOMERIC ISOLATORS ELASTOMERIC ISOLATORS ELASTOMERIC ISOLATORS series SI S02 INTRODUCTION CERTIFICATIONS In 1992, FIP Industriale secured CISQ-ICIM certification for its Quality Assurance System in conformance with EN 29001

More information

United Kingdom Civil Aviation Authority. Specification No. 1. Issue: 6. Date: 12 March Safety Belts ISBN

United Kingdom Civil Aviation Authority. Specification No. 1. Issue: 6. Date: 12 March Safety Belts ISBN ISBN 1 904862 65 9 Specification No. 1 United Kingdom Civil Aviation Authority Issue: 6 Date: 12 March 2004 Safety Belts 1 Introduction 1.1 Although this Specification was written originally for aeroplanes,

More information

DESIGN CHART # 1: Lamit Basic S.I.P Properties

DESIGN CHART # 1: Lamit Basic S.I.P Properties DESIGN CHART # 1: Lamit Basic S.I.P Properties LAMIT S.I.P. PROPERTIES - WEAK AXIS ORIENTED PARALLEL TO SPAN Panel Weight Core Facing Moment Section Elastic Shear Shear Radius Allowable Allowable Allowable

More information

Quick Selection Guide

Quick Selection Guide topspan Quick Selection Guide 1 LYSAGHT topspan LYSAGHT topspan 2 Introduction In response to industry needs, Lysaght has developed a range of selection tables for the Lysaght range of TOPSPAN profiles.

More information

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved. General Installation Manual for SANYO HIT Photovoltaic Modules. Please read this manual completely before use of, or installation of HIT Power modules. This manual applies to the following models: HIT

More information

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic) PosiTest Pull-Off Adhesion Tester INSTRUCTION MANUAL v. 4.0 PosiTest AT-M (manual) PosiTest AT-A (automatic) Introduction The portable, hand-operated PosiTest Pull-Off Adhesion Tester measures the force

More information

NZS 4522:2010. Incorporating Amendment No. 1. New Zealand Standard. Underground fire hydrants. Superseding NZS/BS 750:1984 NZS 4522:2010

NZS 4522:2010. Incorporating Amendment No. 1. New Zealand Standard. Underground fire hydrants. Superseding NZS/BS 750:1984 NZS 4522:2010 Incorporating Amendment No. 1 New Zealand Standard Underground fire hydrants Superseding NZS/BS 750:1984 COMMITTEE REPRESENTATION This standard was prepared under the supervision of the P 4522 Committee

More information

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

side operation magnet ideal transmission side operation magnet

side operation magnet ideal transmission side operation magnet 1 2 3 side operation magnet ideal transmission side operation magnet 4 5 6 The ScreenLine SL20P system comprises a venetian blind incorporating a 12,5 mm slat designed to be integrated in a doubleglazing

More information

BUILDING PRODUCTS LCP PURLINS & GIRTS. Purlin and Girt Structural System. BC 1:2012 FPC Cert. No. ABS-BCI-SG-0001

BUILDING PRODUCTS LCP PURLINS & GIRTS. Purlin and Girt Structural System. BC 1:2012 FPC Cert. No. ABS-BCI-SG-0001 BUILDING PRODUCTS LCP PURLINS & GIRTS Purlin and Girt Structural System BC 1:2012 FPC Cert. No. ABS-BCI-SG-0001 CERT NO. FM 59595 BS EN ISO 9001 : 2008 FEATURES Cold formed purlins and girts are recognised

More information

Innovative Solutions

Innovative Solutions Innovative Solutions 2 1 MK4 Introduction mk MK4 Elastomeric Bearings are deformable structural components constructed partially or wholly from elastomer. They are essentially designed to transmit vertical

More information

3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 STEEL

3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 STEEL 3NL-32 / 3NI-32 / 3PLN-32 ROOF DECK GRADE 50 STEEL 3NL-32 Used With Sidelap Screws 3NI-32 Used With TSWs or BPs 3PLN-32 Used With PunchLok II System Nominal Dimensions Nested Sidelap 3NL-32 Interlocking

More information

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven Model CBD Belt Driven Model CDD Direct Drive CENTAXIAL TUBULAR CENTRIFUGAL FANS BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) CATALOG 337 February 2004 Centaxial

More information

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07 General Installation Manual for SANYO HIT Photovoltaic Modules. Please read this manual completely before use or installation of SANYO modules. This manual applies to the following models: HIP-205BA3,

More information

MBG GRATINGS. MBG Metal Bar Grating HEAVY DUTY MANUAL METAL BAR GRATING AMERICAN NATIONAL STANDARD ANSI/NAAMM STANDARD GRATINGS FIFTH EDITION

MBG GRATINGS. MBG Metal Bar Grating HEAVY DUTY MANUAL METAL BAR GRATING AMERICAN NATIONAL STANDARD ANSI/NAAMM STANDARD GRATINGS FIFTH EDITION METAL BAR GRATING AMERICAN NATIONAL STANDARD ANSI/NAAMM STANDARD MBG 532-09 GRATINGS 5 ANSI/NAAMM HMMA MBG 532-09 October 27, 2009 HEAVY DUTY METAL BAR GRATING MANUAL FIFTH EDITION Maximum Bearing Bar

More information

Australian Standard. Cranes, hoists and winches Safe use. Part 10: Mobile elevating work platforms AS AS

Australian Standard. Cranes, hoists and winches Safe use. Part 10: Mobile elevating work platforms AS AS AS 2550.10 2006 AS 2550.10 2006 Australian Standard Cranes, hoists and winches Safe use Part 10: Mobile elevating work platforms This Australian Standard was prepared by Committee ME-005, Cranes. It was

More information

mini orb w.a. design and installation guide

mini orb w.a. design and installation guide mini orb w.a. design and installation guide lysaght mini orb W.A. 6mm 807mm cover mini orb W.A. is a corrugated sheet with reduced height of corrugation to the more traditional custom orb profile. It is

More information

Henkel has expanded its product portfolio with another important component of vehicle repair and maintenance

Henkel has expanded its product portfolio with another important component of vehicle repair and maintenance Press Release 2016/09/12 Henkel has expanded its product portfolio with another important component of vehicle repair and maintenance In good hands Perhaps more than any other, the automotive industry

More information

diode led BLAZE 12V LED Tape Light 12VDC FEATURES Most popular lighting solution Closet-safe Wide CCT collection Cuttable every 1 inch QUICK SPECS

diode led BLAZE 12V LED Tape Light 12VDC FEATURES Most popular lighting solution Closet-safe Wide CCT collection Cuttable every 1 inch QUICK SPECS diode led a division of elemental LED BLAZE 12V LED Tape Light SPECIFICATION SHEET ACTUAL SIZE Our most popular tape light in our portfolio, BLAZE 12V LED Tape Light is perfect for accent and task lighting

More information

S TRUCTUR A L PR E- A N A LYSIS TA B LES

S TRUCTUR A L PR E- A N A LYSIS TA B LES M A D E F O R U I L D I N G U I L T F O R L I V I N G S TRUTUR A L PR E- A N A LYSIS TA LES I M P R I N T KLH Massivholz GmbH Publisher and responsible for the content: KLH Massivholz GmbH Version: Structural

More information

ARMYLOR PTFE BELLOWS & COMPENSATORS

ARMYLOR PTFE BELLOWS & COMPENSATORS ARMYLOR PTFE BELLOWS & COMPENSATORS CONTENT MERSEN ANTICORROSION EQUIPMENT p.2 RANGE OF BELLOWS & COMPENSATORS p.3 REFERENCES p.4 TECHNICAL SPECIFICATIONS p.5-6 BELLOW FLANGES p.7 COMPENSATOR FLANGES p.8

More information

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL OHCL Outside Horizontal Closable Louvers - mm Curved Profile 226-228F OHCL 124 Outside Horizontal Closable Louvers

More information

FUSO Genuine Parts and Accessories

FUSO Genuine Parts and Accessories FUSO Genuine Parts and Accessories FUSO Genuine Parts and Accessories Engineered by FUSO with passion and precision just like your truck, to give you the best in quality & reliability. This means you can

More information

TRADE OF VEHICLE BODY REPAIR

TRADE OF VEHICLE BODY REPAIR TRADE OF VEHICLE BODY REPAIR PHASE 2 Module 3 UNIT: 6 Door Skinning Produced by In cooperation with subject matter expert: Maurice Stack Some material courtesy of CDX Global and FENC Further Education

More information

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 * SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 * PRODUCT: Stock Car Steel Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating

More information

Rogue Premium Plus 5YEAR. High Performance Wood Doors For Tough Conditions, Featuring A 5-Year No Overhang Guarantee

Rogue Premium Plus 5YEAR. High Performance Wood Doors For Tough Conditions, Featuring A 5-Year No Overhang Guarantee Rogue Premium Plus High Performance Wood Doors For Tough Conditions, Featuring A 5-Year No Overhang Guarantee 5YEAR NO OVERHANG GUARANTEE Door 4612 (IG) in Fir with Rogue Premium Plus Rogue Premium Plus

More information

LPCB LPS 1175 APPROVED PRODUCTS

LPCB LPS 1175 APPROVED PRODUCTS LPCB LPS 1175 APPROVED PRODUCTS LPCB LPS 1175 covers physical security products and services, and comprises of a number of security ratings from 1-8 and these are known as Security Ratings (SR). The ratings

More information

Disc Grinder PDA-100H. Handling Instructions. Read through carefully and understand these instructions before use.

Disc Grinder PDA-100H. Handling Instructions. Read through carefully and understand these instructions before use. Disc Grinder PDA100H Handling Instructions Read through carefully and understand these instructions before use. 1 2 4 6 8 1 2 3 4 5 6 7 9 0 8 L K I G 1 3 5 7 15 ~30 A B 1 A D 5 9 8 B C 0 1 2 J 4 5 8 0

More information

SFI SPECIFICATION 27.1 EFFECTIVE: OCTOBER 11, 2006 *

SFI SPECIFICATION 27.1 EFFECTIVE: OCTOBER 11, 2006 * SFI SPECIFICATION 27.1 EFFECTIVE: OCTOBER 11, 2006 * PRODUCT: Window Nets 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating and

More information

TRIMOTERM FIREPROOF PANELS

TRIMOTERM FIREPROOF PANELS TRIMOTERM FIREPROOF PANELS Index 1 TRIMOTERM FIREPROOF PANELS 2 Trimoterm Power 6 Trimoterm Perform 10 Trimoterm Sound 13 TYPES OF TRIMOTERM PANELS AND PANEL PROFILES 14 Types of Trimoterm panels 16 Trimoterm

More information

Why bigger isn t always better: the case for thin section bearings

Why bigger isn t always better: the case for thin section bearings White Paper Why bigger isn t always better: the case for thin section bearings Richard Burgess, Les Miller and David VanLangevelde, Kaydon Bearings Typical applications Thin section bearings have proven

More information

ENDURAL BALUSTRADE SYSTEM Unhindered Visual Freedom

ENDURAL BALUSTRADE SYSTEM Unhindered Visual Freedom ALSPEC ENDURAL BALUSTRADE system 1 2 ENDURAL BALUSTRADE SYSTEM Unhindered Visual Freedom The EndurAl Balustrade System from Alspec has been developed to provide Architects and Builders an engineered and

More information

ENERGY EFFICIENCY NATIONAL BUILDING REGULATIONS. Development Management Department 1 of 49

ENERGY EFFICIENCY NATIONAL BUILDING REGULATIONS. Development Management Department 1 of 49 ENERGY EFFICIENCY NATIONAL BUILDING REGULATIONS 1 of 49 BACKGROUND 2 of 49 National Energy Efficiency Strategy of the Republic of South Africa March 2005 ( Reviewed 2008 / 2011 ) 3 of 49 OBJECTIVES Develop

More information

SFI SPECIFICATION 15.4 EFFECTIVE: JULY 20, 2010 * PRODUCT: Top Fuel and Funny Car Drag Race Drive Beadlock Wheels

SFI SPECIFICATION 15.4 EFFECTIVE: JULY 20, 2010 * PRODUCT: Top Fuel and Funny Car Drag Race Drive Beadlock Wheels SFI SPECIFICATION 15.4 EFFECTIVE: JULY 20, 2010 * PRODUCT: Top Fuel and Funny Car Drag Race Drive Beadlock Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures

More information

CONTENTS. Key to Access. SUSPENDED PLATFORMS BMU-cradles and MSP s for every type of suspension method.

CONTENTS. Key to Access. SUSPENDED PLATFORMS BMU-cradles and MSP s for every type of suspension method. Key to Access FACADE AND GLASS ROOF ACCESS SYSTEMS Key to Access CONTENTS Together with our dealers around the world, we are always ready to help you to work out the best solution for your access needs.

More information

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013 ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame Australian Version October 2013 ODP SERIES (OPEN DRIP PROOF) PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS, C280M TO C355LB FRAME

More information

PRECISION BELLOWS COUPLINGS

PRECISION BELLOWS COUPLINGS PRECISION BELLOWS COUPLINGS Bellows couplings are used where precise rotation, high speeds, and dynamic motion must be transmitted. They exhibit zero backlash and a high level of torsional stiffness, offering

More information