TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION"

Transcription

1 Heating TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, HC, UC, MH CFM TON COILS HORIZONTAL DUCT HD UPFLOW UNCASED UC HORIZONTAL CASED HC ISO 9001 Certified Quality Management System Air Conditioning UPFLOW/DOWNFLOW UNCASED MH FULL CASED MULTI-POSITION MC UPFLOW PARTIAL CASED PC UPFLOW/DOWNFLOW FULL CASED FC Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at for the most up-to-date technical information. Additional rating information can be found at R DESCRIPTION These cooling and heat pump coils are designed to be installed with UPG furnaces and to be matched with UPG cooling and heat pump outdoor units. Coils ordered with an R22 TXV factory installed can be easily converted to R410A by changing the bolt-on TXV. Some coil models can also be ordered with an R410A TXV and possibly converted to R22 in the same fashion. Flex-coils are also available without a factory installed metering device. For added application flexibility an orifice metering device or an R410A TXV should be installed, on Flex-coils, in the field to meet your refrigerant choice. Upflow / Downflow Coils Full Cased and Partial Cased Coils - Designed for high-efficiency to match any system. Full cased in the upflow or downflow and the partial cased in the upflow only application. Multi-Position Coils - Designed for high-efficiency just like the upflow/downflow coil but with the added flexibility that allows it to be installed in any position upflow, downflow, or horizontal right or left. This coil can be easily applied to UPG furnace and modular air handler in any configuration. Horizontal Duct Coils - Dedicated horizontal, slab coil available for both cooling and heat pump applications. Field transition may be required. Dedicated Horizontal Cased Coils These coils are for cooling and heat pump applications with horizontal furnaces or modular air handlers. Unlike the horizontal duct coils, these cased coils match the dimensions of the furnace or modular blower. FEATURES Thermal Expansion Valve - Provides flexibility to convert any coil to R410A refrigerant. A true bolt-on TXV valve assembly and equalizer tube don t require brazing. TXV and sensing bulb are mounted inside the cased coil cabinet. (must be field supplied for all Flex-coils ) Insulated Cabinet - Evaporator coil cabinets are thermally insulated with foil faced insulation to prevent sweating. HD coils use fiberglass turfskin insulation. Internally Clean - All evaporator coils are factory leak-tested, dehydrated, sealed and shipped with a holding charge. The suction and liquid lines are sealed with rubber plugs - no cutting of connection stubs to attach line set. Durable ish Inside and Out - Coil casings are made of prepainted steel. Pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. All internal metal parts are made of G90 galvanized. Optimum Heat Transfer - Using the latest in heat transfer technology, staggered rows of copper tubes are mechanically expanded into aluminum fins to provide optimum air to surface contact for ample moisture removal as well as high performance ratings. ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kits - Thermal expansion valve kits are available for Flex-coil applications, for converting R22 to R410A refrigerant or as a service replacement. All TXV kits are non-braze all connections are bolt-on including the valve assembly and equalizer tube. No orifice or any other metering device is to be used in conjunction with the TXV. Coil Casing Without Coil Coil casings are available in four widths that can be installed with the furnace or modular air handler during initial installation. This option is available to allow the installer the flexibility to add the coil at a later date without duct modifications. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

2 COOLING CAPACITY - Coil Only * FC18A PC18A FC18B PC18B FC24A PC24A FC24B PC24B FC30(A,B) PC30(A,B) FC3 PC3 FC35(B,C) PC35(B,C) FC37A PC37A FC36A PC36A FC36(B,C) PC36(B,C) FC42(B,C) PC42(B,C) FC43(B,C) PC43(B,C) FC48(C,D) PC48(C,D) FC60(C,D) PC60(C,D) Rated CFM FC62D 1850 FC Entering Evaporator Temperature and Corresponding Pressure F / PSIG Air F (Wet Bulb) 35 / / / / 84.0 UPFLOW "A" TYPE * - See Condensing Unit or Heat Technical Guide for Total Cooling Capacity and Sensible Capacity. 2 Johnson Controls Unitary Products

3 COOLING CAPACITY - COIL ONLY * Coil Rated CFM MC18A 550 MC18B 650 MC24(A,B) 850 MC30(A,B) MC3 MC35(B,C) MC37A MC36A 1150 MC36B 1250 MC36C 1250 MC42(B,C) 1400 MC43(B,C) 1400 MC48(C,D) 1650 MC60D 1825 MC62D 2000 * See Condensing Unit or Heat Technical Guide for Total Cooling Capacity and Sensible Capacity. Notes: MC coils available with a factory installed horizontal drain pan option (H). Entering Air F Evaporator Temperature and Corresponding Pressure F / PSIG (Wet Bulb) 35 / / / / 84.0 FULL-CASED A TYPE MULTI-POSITION Johnson Controls Unitary Products 3

4 COOLING CAPACITY - Coil Only * MODEL RATED CFM HD24S 815 HD HD48S 1610 HD60S 2100 ENTERING Evaporator Temperature and Corresponding Pressure F/ PSIG AIR F (Wet Bulb) 35 / / / / 84.0 HORIZONTAL DUCT TYPE * See Condensing Unit or Heat Technical Guide for Total Cooling Capacity and Sensible Capacity. COOLING CAPACITY - COIL ONLY * Rated CFM HC18A 600 HC30A 1000 HC36B 1200 HC42C 1400 HC60D 1800 Entering Air F (Wet Bulb) EVAPORATOR TEMPERATURE AND CORRESPONDING PRESSURE F / PSIG 35/ / / / * See Condensing Unit or Heat Technical Guide for Total Cooling Capacity and Sensible Capacity. APPLICATION FACTOR-RATED CFM VS. ACTUAL CFM % OF RATED AIR FLOW 80% 90% RATED CFM 110% 120% CAPACITY FACTOR NOTE:Do not exceed minimum/maximum CFM limits shown under Air Flow Data. APPLICATION LIMITATIONS These units must be installed in accordance with all national and local safety codes. Air flow must be within the minimum and maximum limits approved for electric heat, evaporator coils and outdoor units. Entering Air Temperature Limits Wet Bulb Temp. ºF Dry Bulb Temp. ºF Min. Max. Min. Max Johnson Controls Unitary Products

5 COOLING CAPACITY - COIL ONLY * Coil Rated CFM UC18(A,B) 600 UC24(A,B) 800 UC30(A,B) 1000 UC36A 1150 UC36(B,C) 1200 UC42(B,C) 1400 UC48(C,D) 1600 UC60(C,D) 1800 Entering Air F (Wet Bulb) Evaporator Temperature and Corresponding Pressure F / PSIG 35 / / / / 84.0 Uncased Upflow * See Condensing Unit or Heat Technical Guide for Total Cooling Capacity and Sensible Capacity. COOLING CAPACITY - COIL ONLY * Coil Rated CFM MH MH MH MH Entering Air F Evaporator Temperature and Corresponding Pressure F / PSIG (Wet Bulb) 35 / / / / 84.0 Uncased Upflow/Downflow * See Condensing Unit or Heat Technical Guide for Total Cooling Capacity and Sensible Capacity. Johnson Controls Unitary Products 5

6 STATIC PRESSURE VS. AIRFLOW (BASED ON WET COIL) UPFLOW CASED "A" TYPE HORIZONTAL - DUCT TYPE Airflow Wet Coil FC18A PC18A FC18B PC18B FC24A PC24A FC24B PC24B FC30A, PC30A FC3, PC3 FC30B PC30B FC35B PC35B FC35C PC35C FC36A PC36A FC36B PC36B FC37A PC37A FC36C PC36C FC42B PC42B FC42C, PC42C FC43B, PC43B FC43C PC43C FC48C PC48C FC48D PC48D FC60C PC60C FC60D PC60D FC62D FC64D Airflow Wet Coil HD24S HD36S HD48S HD60S HORIZONTAL CASED Airflow Wet Coil HC18A HC30A HC36B HC42C HC60D UNCASED UPFLOW/DOWNFLOW - A TYPE Airflow Wet Coil MH MH MH MH Johnson Controls Unitary Products

7 CASED "A" TYPE MULTI-POSITION Airflow Wet Coil MC18A MC18B MC24A MC24B MC30A MC MC30B MC35B MC35C MC36A MC37A MC36B MC36C MC42B MC42C MC43C MC48C MC48D MC60D MC62D UNCASED UPFLOW - A TYPE Airflow Wet Coil UC18A UC18B UC24A UC24B UC30A UC30B UC36A UC36B UC36C UC42B UC42C UC48C UC48D UC60C UC60D Johnson Controls Unitary Products 7

8 PHYSICAL DATA UNCASED UPFLOW - A TYPE UC18A3XN1 UC18AN1 UC18B3XN1 UC18BN1 UC24A3XN1 UC24AN1 UC24B3XN1 UC24BN1 UC30A3XN1 UC30AN1 UC30B3XN1 UC30BN1 UC36A3XN1 UC36AN1 UC36B3XN1 UC36BN1 UC36C3XN1 UC36CN1 UC42B3XN1 UC42B2CN1 UC42C3XN1 UC42C2CN1 UC48C3XN1 UC48C2CN1 UC48D3XN1 UC48D2CN1 UC60C3XN1 UC60C2CN1 UC60D3XN1 UC60D2CN1 Application Refrig. Conn. Types Face Area (Sq. Ft.) Rows Deep Per In. Coil Size Geometry Dia. Type Sweat (2) 16 x x /8 Enhanced Sweat (2) 16 x x /8 Enhanced Sweat (2) 20 x x /8 Enhanced Sweat (2) 20 x x /8 Enhanced Sweat (2) 20 x x /8 Enhanced Sweat (2) 20 x x /8 Enhanced Sweat (2) 22 x x /8 Enhanced Sweat (2) 22 x x /8 Enhanced Sweat (2) 22 x x /8 Enhanced Sweat (2) 26 x x /8 Enhanced Sweat (2) 26 x x /8 Enhanced Sweat (2) 24 x x /8 Enhanced Sweat (2) 24 x x /8 Enhanced Sweat (2) 26 x x /8 Enhanced Sweat (2) 26 x x /8 Enhanced TXV 2C 2C 2C 2C 2C 2C Operating Weight (Lbs.) HORIZONTAL CASED TYPE HC18A3XH1 HC18AH1 HC30A3XH1 HC30AH1 HC36B3XH1 HC36BH1 HC42C3XH1 HC42C2CH1 HC60D3XH1 HC60D2CH1 Application Refrig. Conn. Types Face Area (Sq. Ft.) Rows Deep Per In. Coil Size Geometry Dia. Type Sweat (2) 14 x x /8 Enhanced Sweat (2) 16 x x /8 Enhanced Sweat (2) 20 x x /8 Enhanced Sweat (2) 24 x x /8 Enhanced TXV 2C 2C Operating Weight (Lbs.) Johnson Controls Unitary Products

9 HORIZONTAL - DUCT TYPE Application Refrig. Conn. Types Face Area (Sq. Ft.) Rows Deep Per In. Coil Size Geometry HD24S3XH1 33 Sweat x 24 1 x /8 Enhanced HD24SH1 35 HD36S3XH1 35 Sweat x 24 1 x /8 Enhanced HD36SH1 37 HD48S3XH1 38 Sweat x 24 1 x /8 Enhanced HD48S2CH1 2C 40 HD60S3XH1 46 Sweat x 24 1 x /8 Enhanced HD60S2CH1 2C 48 CASED UPFLOW/DOWNFLOW AND PARTIAL CASED Application Refrig. Conn. Types Face Area (Sq. Ft.) Rows Deep Per In. Coil Size Geometry Dia. Dia. Type Type TXV Operating Weight (Lbs.) Operating TXV Weight (Lbs.) 42 FC18A3XN1 FC18AN1 Sweat (2) 14 x x /8 Enhanced 42 Heat FC18A4FN1 4F 42 FC18B3XN1 44 FC18BN1 Sweat (2) 14 x x /8 Enhanced 44 Heat FC18B4FN1 4F 44 FC24A3XN1 46 FC24AN1 Sweat (2) 18 x x /8 Enhanced 46 Heat FC24A4FN1 4F 46 FC24B3XN1 50 FC24BN1 Sweat (2) 18 x x /8 Enhanced 50 Heat FC24B4FN1 4F 50 FC30A3XN1 46 FC30AN1 Sweat (2) 18 x x /8 Enhanced 46 Heat FC30A4FN1 4F 46 FC30B3XN1 50 FC30BN1 Sweat (2) 18 x x /8 Enhanced 50 Heat FC30B4FN1 4F 50 FC33XN1 49 FC3N1 51 Sweat (2) 16 x x /8 Enhanced FC34FN1 Heat 4F 51 FC34GN1 4G 51 FC35B3XN2 53 FC35BN1 55 FC35B4FN1 Sweat (2) 16 x x /8 Enhanced 4F 55 Heat FC35B4GN1 4G 55 FC35B4HN1 4H 55 FC35C3XN(1,2) 55 FC35CN1 57 FC35C4FN1 Sweat (2) 16 x x /8 Enhanced 4F 57 Heat FC35C4GN1 4G 57 FC35C4HN1 4H 57 FC36A3XN1 51 FC36AN1 51 FC36A4FN1 Sweat (2) 20 x x /8 Enhanced 4F 51 Heat FC36A4GN1 4G 51 FC36A4HN1 4H 51 FC36B3XN1 53 FC36BN1 53 FC36B4FN1 Sweat (2) 20 x x /8 Enhanced 4F 53 Heat FC36B4GN1 4G 53 FC36B4HN1 4H 53 Johnson Controls Unitary Products 9

10 CASED UPFLOW/DOWNFLOW AND PARTIAL CASED Application Refrig. Face Operating Conn. Area Rows Per Coil Size TXV Weight Types (Sq. Ft.) Deep In. Geometry Dia. Type (Lbs.) FC36C3XN1 55 FC36CN1 55 FC36C4FN1 Sweat (2) 20 x x /8 Enhanced 4F 55 Heat FC36C4GN1 4G 55 FC36C4HN1 4H 55 FC37A3XN1 56 FC37AN1 Sweat (2) 20 x x /8 Enhanced 58 Heat FC37A4FN1 4F 58 FC42B3XN1 62 FC42B2CN1 2C 62 Sweat (2) 24 x x /8 Enhanced FC42B4FN1 Heat 4F 62 FC42B4HN1 4H 62 FC42C3XN1 64 FC42C2CN1 2C 64 Sweat (2) 24 x x /8 Enhanced FC42C4FN1 Heat 4F 64 FC42C4HN1 4H 64 FC43B3XN1 57 FC43B2CN1 2C 58 FC43B4FN1 Sweat (3) 20 x x /8 Enhanced 4F 58 Heat FC43B4GN1 4G 58 FC43B4KN1 4K 58 FC43C3XN1 58 FC43C2CN1 2C 60 FC43C4FN1 Sweat (2) 20 x x /8 Enhanced 4F 60 Heat FC43C4GN1 4G 60 FC43C4KN1 4K 60 FC48C3XN1 65 FC48C2CN1 2C 65 FC48C4FN1 4F 65 Sweat (2) 22 x x /8 Enhanced FC48C4HN1 Heat 4H 65 FC48C4JN1 4J 65 FC48C4KN1 4K 65 FC48D3XN1 73 FC48D2CN1 2C 73 FC48D4FN1 4F 73 Sweat (2) 22 x x /8 Enhanced FC48D4HN1 Heat 4H 73 FC48D4JN1 4J 73 FC48D4KN1 4K 73 FC60C3XN1 65 FC60C2CN1 2C 65 FC60C4GN1 4G 65 Sweat (2) 24 x x /8 Enhanced FC60C4HN1 Heat 4H 65 FC60C4JN1 4J 65 FC60C4KN1 4K 65 FC60D3XN1 78 FC60D2CN1 2C 78 FC60D4GN1 4G 78 Sweat (2) 24 x x /8 Enhanced FC60D4HN1 Heat 4H 78 FC60D4JN1 4J 78 FC60D4KN1 4K 78 FC62D3XN1 88 FC62D2CN1 2C 90 FC62D4HN1 Sweat (2) 28 x x /8 Enhanced 4H 90 Heat FC62D4JN1 4J 90 FC62D4KN1 4K 90 FC64D3XN1 Heat Sweat (2) 32x x /8 Enhanced Johnson Controls Unitary Products

11 CASED UPFLOW A TYPE Application Refrig. Conn. Types Face Area (Sq. Ft.) Rows Deep Per In. Coil Size Geometry PC18A3XN1 36 Sweat (2) 14 x x /8 Enhanced PC18AN1 Heat 36 PC18B3XN1 37 Sweat (2) 14 x x /8 Enhanced PC18BN1 Heat 37 PC24A3XN1 40 Sweat (2) 18 x x /8 Enhanced PC24AN1 Heat 40 PC24B3XN1 42 Sweat (2) 18 x x /8 Enhanced PC24BN1 Heat 42 PC30A3XN1 40 Sweat (2) 18 x x /8 Enhanced PC30AN1 Heat 40 PC30B3XN1 42 Sweat (2) 18 x x /8 Enhanced PC30BN1 Heat 42 PC33XN1 41 Sweat (2) 16 x x /8 Enhanced PC3N1 Heat 43 PC35B3XN2 45 Sweat (2) 16 x x /8 Enhanced PC35BN1 Heat 47 PC35C3XN2 46 Sweat (2) 16 x x /8 Enhanced PC35CN1 Heat 48 PC36A3XN1 44 Sweat (2) 20 x x /8 Enhanced PC36AN1 Heat 44 PC36B3XN1 45 Sweat (2) 20 x x /8 Enhanced PC36BN1 Heat 45 PC36C3XN1 46 Sweat (2) 20 x x /8 Enhanced PC36CN1 Heat 46 PC37A3XN1 48 Sweat (2) 20 x x /8 Enhanced PC37AN1 Heat 50 PC42B3XN1 50 Sweat (2) 24 x x /8 Enhanced PC42B2CN1 Heat 2C 50 PC42C3XN1 54 Sweat (2) 24 x x /8 Enhanced PC42C2CN1 Heat 2C 54 PC43B3XN1 47 Sweat (3) 20 x x /8 Enhanced PC43B2CN1 Heat 2C 49 PC43C3XN1 49 Sweat (2) 20 x x /8 Enhanced PC43C2CN1 Heat 2C 51 PC48C3XN1 56 Sweat (2) 22 x x /8 Enhanced PC48C2CN1 Heat 2C 56 PC48D3XN1 58 Sweat (2) 22 x x /8 Enhanced PC48D2CN1 Heat 2C 58 PC60C3XN1 58 Sweat (2) 24 x x /8 Enhanced PC60C2CN1 Heat 2C 58 Dia. Type TXV Operating Weight (Lbs.) PC60D3XN1 60 Sweat (2) 24 x x /8 Enhanced PC60D2CN1 Heat 2C 60 Johnson Controls Unitary Products 11

12 FULL CASED A TYPE MULTI-POSITION Application Refrig. Conn. Types Face Area (Sq. Ft.) Rows Deep Per In. Coil Size Geometry MC18A3XH1 53 MC18AH1 Sweat (2) 14 x x /8 Enhanced 53 MC18A4FH1 4F 53 MC18B3XH1 53 MC18BH1 Sweat (2) 14 x x /8 Enhanced 53 MC18B4FH1 4F 53 MC24A3XH1 56 MC24AH1 Sweat (2) 18 x x /8 Enhanced 56 MC24A4FH1 4F 56 MC24B3XH1 56 MC24BH1 Sweat (2) 18 x x /8 Enhanced 56 MC24B4FH1 4F 56 MC30A3XH1 56 MC30AH1 Sweat (2) 18 x x /8 Enhanced 56 MC30A4FH1 4F 56 MC30B3XH1 56 MC30BH1 Sweat (2) 18 x x /8 Enhanced 56 MC30B4FH1 4F 56 MC33XH1 MC3H1 61 Sweat (2) 16 x x /8 Enhanced MC34FH1 4F 61 Dia. Type TXV Operating Weight (Lbs.) 59 MC34GH1 4G 61 MC35B3XH2 65 MC35BH1 67 MC35B4FH1 Sweat (2) 16 x x /8 Enhanced 4F 67 MC35B4GH1 4G 67 MC35B4HH1 4H 67 MC35C3XH(1,2) 67 MC35CH1 69 MC35C4FH1 Sweat (2) 16 x x /8 Enhanced 4F 69 MC35C4GH1 4G 69 MC35C4HH1 4H 69 MC36A3XH1 64 MC36AH1 64 MC36A4FH1 Sweat (2) 20 x x /8 Enhanced 4F 64 MC36A4GH1 4G 64 MC36A4HH1 4H 64 MC36B3XH1 65 MC36BH1 65 MC36B4FH1 Sweat (2) 20 x x /8 Enhanced 4F 65 MC36B4GH1 4G 65 MC36B4HH1 4H 65 MC36C3XH1 65 MC36CH1 65 MC36C4FH1 Sweat (2) 20 x x /8 Enhanced 4F 65 MC36C4GH1 4G 65 MC36C4HH1 4H 65 MC37A3XH1 63 MC37AH1 Sweat (2) 20 x x /8 Enhanced 63 MC37A4FH1 4F Johnson Controls Unitary Products

13 FULL CASED A TYPE MULTI-POSITION YTG-A-0809 MC42B3XH1 72 MC42B2CH1 2C 72 Sweat (2) 24 x x /8 Enhanced MC42B4FH1 4F 72 MC42B4HH1 4H 72 MC42C3XH1 72 MC42C2CH1 2C 72 Sweat (2) 24 x x /8 Enhanced MC42C4FH1 4F 72 MC42C4HH1 4H 72 MC43B3XH1 73 MC43B2CH1 2C 73 MC43B4FH1 Sweat (2) 20 x x /8 Enhanced 4F 73 MC43B4GH1 4G 73 MC43B4KH1 4K 73 MC43C3XH1 75 MC43C2CH1 2C 75 MC43C4FH1 Sweat (2) 20 x x /8 Enhanced 4F 75 MC43C4GH1 4G 75 MC43C4KH1 4K 75 MC48C3XH1 82 MC48C2CH1 2C 82 MC48C4FH1 4F 82 Sweat (2) 22 x x /8 Enhanced MC48C4HH1 4H 82 MC48C4JH1 4J 82 MC48C4KH1 4K 82 MC48D3XH1 82 MC48D2CH1 2C 82 MC48D4FH1 4F 82 Sweat (2) 22 x x /8 Enhanced MC48D4HH1 4H 82 MC48D4JH1 4J 82 MC48D4KH1 4K 82 MC60D3XH1 86 MC60D2CH1 2C 86 MC60D4GH1 4G 86 Sweat (2) 24 x x /8 Enhanced MC60D4HH1 4H 86 MC60D4JH1 4J 86 MC60D4KH1 4K 86 MC62D3XH1 98 MC62D2CH1 2C 98 MC62D4HH1 Sweat (2) 28 x x /8 Enhanced 4H 98 MC62D4JH1 4J 98 MC62D4KH1 4K 98 Note: MC coils available with a factory installed horizontal drain pan option (H). Johnson Controls Unitary Products 13

14 DIMENSIONS 20 3/8 (Opening) A COIL - MC 3/4 Flange C 21.5 Dimensions - MC Coils B 20 1/4 BOTTOM OPENING DIMENSIONS A B C D Refrigerant Line Size * Liquid Vapor Factory Installed TXV MC18AH / /8 3/4 MC18A3XH / /8 3/4 MC18A4FH / /8 3/4 4F MC18BH / /8 3/4 MC18B3XH / /8 3/4 MC18B4FH / /8 3/4 4F MC24AH / /8 3/4 MC24A3XH / /8 3/4 MC24A4FH / /8 3/4 4F MC24BH / /8 3/4 MC24B3XH / /8 3/4 MC24B4FH / /8 3/4 4F MC30AH / /8 3/4 MC30A3XH / /8 3/4 MC30A4FH / /8 3/4 4F MC30BH / /8 3/4 MC30B3XH / /8 3/4 MC30B4FH / /8 3/4 4F MC3H / /8 3/4 MC33XH / /8 3/4 MC34FH / /8 3/4 4F MC34GH / /8 3/4 4G MC35BH / /8 3/4 MC35B3XH / /8 3/4 MC35B4FH / /8 3/4 4F MC35B4GH / /8 3/4 4G MC35B4HH / /8 3/4 4H MC35CH /8 20 3/8 3/4 MC35C3XH(1,2) / /8 20 3/8 3/4 MC35C4FH /8 20 3/8 3/4 4F MC35C4GH /8 20 3/8 3/4 4G MC35C4HH /8 20 3/8 3/4 4H MC36AH / /8 7/8 MC36A3XH / /8 7/8 MC36A4FH / /8 7/8 4F MC36A4GH / /8 7/8 4G MC36A4HH / /8 7/8 4H D Dimensions - MC Coils Refrigerant Factory A B C D Line Size * Installed Liquid Vapor TXV MC36BH / /8 7/8 MC36B3XH / /8 7/8 MC36B4FH / /8 7/8 4F MC36B4GH / /8 7/8 4G MC36B4HH / /8 7/8 4H MC36CH /8 20 3/8 7/8 MC36C3XH /8 20 3/8 7/8 MC36C4FH /8 20 3/8 7/8 4F MC36C4GH /8 20 3/8 7/8 4G MC36C4HH /8 20 3/8 7/8 4H MC37AH / /8 3/4 MC37A3XH / /8 3/4 MC37A4FH / /8 3/4 4F MC42B2CH / /8 7/8 2C MC42B3XH / /8 7/8 MC42B4FH / /8 7/8 4F MC42B4HH / /8 7/8 4H MC42C2CH /8 20 3/8 7/8 2C MC42C3XH /8 20 3/8 7/8 MC42C4FH /8 20 3/8 7/8 4F MC42C4HH /8 20 3/8 7/8 4H MC43B2CH / /8 7/8 2C MC43B2FH / /8 3/4 4F MC43B3XH / /8 7/8 MC43B4GH / /8 7/8 4G MC43B4KH / /8 7/8 4K MC43C2CH /8 20 3/8 7/8 2C MC43C2FH /8 20 3/8 7/8 4F MC43C3XH /8 20 3/8 7/8 MC43C4GH /8 20 3/8 7/8 4G MC43C4KH /8 20 3/8 7/8 4K MC48C2CH /8 20 3/8 7/8 2C MC48C3XH /8 20 3/8 7/8 MC48C4FH /8 20 3/8 7/8 4F MC48C4HH /8 20 3/8 7/8 4H MC48C4JH /8 20 3/8 7/8 4J MC48C4KH /8 20 3/8 7/8 4K MC48D2CH / /8 7/8 2C MC48D3XH / /8 7/8 MC48D4FH / /8 7/8 4F MC48D4HH / /8 7/8 4H MC48D4JH / /8 7/8 4J MC48D4KH / /8 7/8 4K MC60D2CH / /8 7/8 2C MC60D3XH / /8 7/8 MC60D4GH / /8 7/8 4G MC60D4HH / /8 7/8 4H MC60D4JH / /8 7/8 4J MC60D4KH / /8 7/8 4K MC62D2CH / /8 7/8 2C MC62D3XH / /8 7/8 MC62D4HH / /8 7/8 4H MC62D4JH / /8 7/8 4J MC62D4KH / /8 7/8 4K All MC coils include a factory installed horizontal drain pan. (3X) = s require field installed metering device. * Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin # AD1V for details. 14 Johnson Controls Unitary Products

15 COIL - FC 20 3/8 (Opening) A 3/4 Flange C 21.5 B 20 1/4 BOTTOM OPENING DIMENSIONS Dimensions - FC Coils A B C D Refrigerant Line Size * Liquid Vapor Factory Installed TXV FC18AN / /8 3/4 FC18A3XN / /8 3/4 FC18A4FN / /8 3/4 4F FC18BN / /8 3/4 FC18B3XN / /8 3/4 FC18B4FN / /8 3/4 4F FC24AN / /8 3/4 FC24A3XN / /8 3/4 FC24A4FN / /8 3/4 4F FC24BN / /8 3/4 FC24B3XN / /8 3/4 FC24B4FN / /8 3/4 4F FC30AN / /8 3/4 FC30A3XN / /8 3/4 FC30A4FN / /8 3/4 4F FC30BN / /8 3/4 FC30B3XN / /8 3/4 FC30B4FN / /8 3/4 4F FC3N / /8 3/4 FC33XN / /8 3/4 FC34FN / /8 3/4 20 4F FC34GN / /8 3/4 20 4G FC35BN / /8 3/4 FC35B3XN / /8 3/4 FC35B4FN / /8 3/4 4F FC35B4GN / /8 3/4 4G FC35B4HN / /8 3/4 4H FC35CN /8 20 3/8 3/4 FC35C3XN(1,2) / /8 20 3/8 3/4 FC35C4FN / /8 20 3/8 3/4 4F FC35C4GN / /8 20 3/8 3/4 4G FC35C4HN / /8 20 3/8 3/4 4H FC36AN / /8 7/8 FC36A3XN / /8 7/8 FC36A4FN / /8 7/8 4F FC36A4GN / /8 7/8 4G FC36A4HN / /8 7/8 4H FC36BN / /8 7/8 FC36B3XN / /8 7/8 FC36B4FN / /8 7/8 4F FC36B4GN / /8 7/8 4G D Dimensions - FC Coils YTG-A-0809 Refrigerant Factory A B C D Line Size * Installed Liquid Vapor TXV FC36B4HN / /8 7/8 4H FC36CN /8 20 3/8 7/8 FC36C3XN /8 20 3/8 7/8 FC36C4FN /8 20 3/8 3/4 4F FC36C4GN /8 20 3/8 3/4 4G FC36C4HN /8 20 3/8 3/4 4H FC37AN / /8 3/4 FC37A3XN / /8 3/4 FC37A4FN / /8 3/4 4F FC42B2CN / /8 7/8 2C FC42B3XN / /8 7/8 FC42B4FN / /8 7/8 4F FC42B4HN / /8 7/8 4H FC42C2CN /8 20 3/8 7/8 2C FC42C3XN /8 20 3/8 7/8 FC42C4FN /8 20 3/8 7/8 4F FC42C4HN /8 20 3/8 7/8 4H FC43B2CN / /8 7/8 2C FC43B3XN / /8 7/8 FC43B4FN / /8 3/4 4F FC43B4GN / /8 3/4 4G FC43B4KN / /8 3/4 4K FC43C2CN /8 20 3/8 7/8 2C FC43C3XN /8 20 3/8 7/8 FC43C4FN /8 20 3/8 3/4 4F FC43C4GN /8 20 3/8 3/4 4G FC43C4KN /8 20 3/8 3/4 4K FC48C2CN /8 20 3/8 7/8 2C FC48C3XN /8 20 3/8 7/8 FC48C4FN /8 20 3/8 7/8 4F FC48C4HN /8 20 3/8 7/8 4H FC48C4JN /8 20 3/8 7/8 4J FC48C4KN /8 20 3/8 7/8 4K FC48D2CN / /8 7/8 2C FC48D3XN / /8 7/8 FC48D4FN / /8 7/8 4F FC48D4HN / /8 7/8 4H FC48D4JN / /8 7/8 4J FC48D4KN / /8 7/8 4K FC60C2CN /8 20 3/8 7/8 2C FC60C3XN /8 20 3/8 7/8 FC60C4GN /8 20 3/8 7/8 4G FC60C4HN /8 20 3/8 7/8 28 4H FC60C4JN /8 20 3/8 7/8 28 4J FC60C4KN /8 20 3/8 7/8 28 4K FC60D2CN / /8 7/8 2C FC60D3XN / /8 7/8 FC60D4GN / /8 7/8 4G FC60D4HN / /8 7/8 4H FC60D4JN / /8 7/8 4J FC60D4KN / /8 7/8 4K FC62D2CN / /8 7/8 2C FC62D3XN / /8 7/8 FC62D4HN / /8 7/8 4H FC62D4JN / /8 7/8 4J FC62D4KN / /8 7/8 4K FC64D3XN / /8 7/8 All FC coils are not available with a factory installed horizontal drain pan. (3X) = s require field installed metering device. * Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin # AD1V for details. Johnson Controls Unitary Products 15

16 20 3/8 (Opening) C (Opening) B 12 A /4 D BOTTOM OPENING DIMENSIONS COIL - PC Dimensions - PC Coils A B C D Refrigerant Line Size * Liquid Vapor Factory Installed TXV PC18AN /4 13 3/ /8 3/4 PC18A3XN /4 13 3/ /8 3/4 PC18BN / /8 3/4 PC18B3XN / /8 3/4 PC24AN /8 16 3/ /8 3/4 PC24A3XN /8 13 3/ /8 3/4 PC24BN /8 16 3/ /8 3/4 PC24B3XN /8 16 3/ /8 3/4 PC30AN /8 13 3/ /8 3/4 PC30A3XN /8 13 3/ /8 3/4 PC30BN /8 16 3/ /8 3/4 PC30B3XN /8 16 3/ /8 3/4 PC3N / /8 3/4 PC33XN / /8 3/4 PC35BN /8 16 3/ /8 3/4 PC35B3XN /8 16 3/ /8 3/4 PC35CN /4 19 7/8 20 3/8 3/4 PC35C3XN /4 19 7/8 20 3/8 3/4 PC36AN /8 13 3/ /8 7/8 PC36A3XN /8 13 3/ /8 7/8 PC36BN /8 16 3/ /8 7/8 PC36B3XN /8 16 3/ /8 7/8 PC36CN /8 19 7/8 20 3/8 7/8 Dimensions - PC Coils Refrigerant Factory A B C D Line Size * Installed Liquid Vapor TXV PC36C3XN /8 19 7/8 20 3/8 7/8 PC37AN /8 13 3/ /8 3/4 PC37A3XN /8 13 3/ /8 3/4 PC42B2CN /8 16 3/ /8 7/8 2C PC42B3XN /8 16 3/ /8 7/8 PC42C2CN /8 19 7/8 20 3/8 7/8 2C PC42C3XN /8 19 7/8 20 3/8 7/8 PC43B2CN /8 16 3/ /8 7/8 2C PC43B3XN /8 16 3/ /8 7/8 PC43C2CN /8 19 7/8 20 3/8 7/8 2C PC43C3XN /8 19 7/8 20 3/8 7/8 PC48C2CN /8 19 7/8 20 3/8 7/8 2C PC48C3XN /8 19 7/8 20 3/8 7/8 PC48D2CN /8 23 3/ /8 7/8 2C PC48D3XN /8 23 3/ /8 7/8 PC60C2CN /2 19 7/8 20 3/8 7/8 2C PC60C3XN /2 19 7/8 20 3/8 7/8 PC60D2CN /8 23 3/ /8 7/8 2C PC60D3XN /8 23 3/ /8 7/8 All PC coils are not available with a factory installed horizontal drain pan. (3X) = s require field installed metering device. * Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin # AD1V for details. 16 Johnson Controls Unitary Products

17 C B A COIL - UC DIMENSIONS - UC Coils UC18A3XN1 UC18AN1 UC18B3XN1 UC18BN1 UC24A3XN1 UC24AN1 UC24B3XN1 UC24BN1 UC30A3XN1 UC30AN1 UC30B3XN1 UC30BN1 UC36A3XN1 UC36AN1 Dimensions Inches A B C Refrigerant Refrigerant Dimensions Inches Connections Connections Line Size * Line Size* A B C Liquid Vapor Liquid Vapor 3/8 UC36B3XN UC36BN1 UC coils are not available with a factory installed horizontal drain pan. (3X) = s require field installed metering device. 3/4 7/8 UC36C3XN1 UC36CN1 UC42B3XN1 UC42B2CN1 UC42C3XN1 UC42C2CN1 UC48C3XN1 UC48C2CN1 UC48D3XN1 UC48D2CN1 UC60C3XN1 UC60C2CN1 UC60D3XN1 UC60D2CN1 * Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin # AD1V for details UC coils are not available with a factory installed horizontal drain pan. (3X) = s require field installed metering device. 3/8 7/8 B 19-1/2 21-1/2 25-1/2 A A C 20-1/4 21-1/2 INLET OPENING DIMENSIONS - HC Coils Dimensions Inches Refrigerant Connections Line Size A B C Liquid Vapor HC18A**H1 3/4 15-5/ /4 14-3/16 HC30A**H1 HC36B**H1 17-9/ /2 16-7/16 3/8 7/8 HC42C**H1 21-5/ /4 20-3/16 HC60D**H1 25-5/ /4 24-3/16 COIL - HC Johnson Controls Unitary Products 17

18 3-3/4 A LIQUID CONN. 1-3/8 2-5/8 D 3/4 MPT SECONDARY DRAIN CONN. VAPOR CONN. B 3/4 MPT PRIMARY DRAIN CONN. 1-3/4 C OUTLET SAME SIZE AS INLET (ALL FLANGES 3/4 THICK 5-5/8 7/8 1-7/8 4-1/8 1-3/8 COIL - HD DIMENSIONS - HD Coils Dimensions Inches A B C D HD24S**H1 28-3/ /4 21-5/8 HD36S**H1 28-3/ /4 25-5/8 HD48S**H1 34-3/ /4 25-5/8 HD60S**H1 34-3/ /4 27-5/8 Refrigerant Connections Line Size Liquid Vapor 3/4 3/8 7/8 S = SWEAT FIT B Q = QUICK CONNECT C A COIL - MH DIMENSIONS - MH Coils Dimensions Inches Refrigerant Connections Line Size * A B C Liquid Vapor MH24(Q,S) 18 3/8 18 1/8 20 3/8 3/4 MH30(Q,S) 18 3/8 18 1/8 20 3/8 3/4 MH36(Q,S) 18 3/8 18 1/8 20 3/8 7/8 MH42(Q,S) 18 3/8 18 1/8 20 3/8 7/8 * Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin # AD1V for details. Subject to change without notice. Published in U.S.A. Copyright 2009 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK YTG-A-0809 Supersedes: YTG-E-0708

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: MC, PC, FC, HD, UC CFM 1.

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: MC, PC, FC, HD, UC CFM 1. Heating TECHNICAL GUIDE Air Conditioning ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS R DESCRIPTION These cooling and heat pump

More information

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System Heating TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC Air Conditioning

More information

TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: CF, CM, CU 600-2000 CFM 1.5-5 TON COILS 5005744-BTG-C-0815 DESCRIPTION These indoor coils are designed to be installed

More information

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES DESCRIPTION 364834-YTG-H-0509 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION 700695-YTG-C-0714 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a

More information

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS CX34 PRODUCT SPECIFICATIONS Upflow - Cased - R-410A Bulletin No. 210322 August 2011 Supersedes August 2010 MODEL NUMBER IDENTIFICATION 18/24 = 1.5/2 tons 30 = 2.5 tons 31 = 2.5 tons 36 = 3

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFP- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,600 CFM [283-755 L/s] Rheem Indoor Coils are designed for use

More information

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS 6EMMX Series Air Handler with TXV 14-15 SEER Residential System 18,000-60,000 tuh (Heat Pump & Air Conditioner) R-410A Refrigerant The 6EMMX Series of air handlers, when combined

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces MODEL: TCF Cased/Uncased Coils For Gas And Oil Furnaces FORM NO. CSC-224 REV. 1 Sure Comfort TCF Cased/Uncased Coils For Gas And Oil Furnaces (TXV Metering Device Shown) Featuring Industry Standard R-410A

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) TECHNICAL SPECIFICATIONS HMG Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG Series of air handlers, when combined with our heat pump or air conditioner,

More information

Modular Variable Speed Air Handlers

Modular Variable Speed Air Handlers Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 2 1/2-5 Ton 2TEE3C31A1000A 2TEE3C37A1000A 2TEE3C40A1000A 2TEE3C49A1000A 2TEE3C65A1000A 4TEE3C31A1000A 4TEE3C37A1000A

More information

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES TEHNIL GUIDE MODELS: MV MODULR VRIBLE SPEED IR HNDLERS FOR USE WITH SPLIT SYSTEM OOLING & HET PUMP 1200-2000 FM BLOWERS 3-5 TON OILS OPTIONL 1 & 3 ELETRI HETERS Due to continuous product improvement, specifications

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without

More information

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCF- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] (TXV Metering Device Shown) Ruud Indoor

More information

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR:

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

TECHNICAL GUIDE R-410A AFFINITY SERIES DEQ, DEX, DEY AND DEZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES DEQ, DEX, DEY AND DEZ MODELS 2-5 TON 60 Hertz TECHNICAL GUIDE R-410A AFFINITY SERIES DEQ, DEX, DEY AND DEZ MODELS 2-5 TON 60 Hertz Description These York Affinity packaged air conditioners are designed for outdoor installation. Only utility and duct

More information

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s) NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor

More information

Air Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011)

Air Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011) Air Handlers ACBX32CM 3 Phase Multi-Position ACBX32CM-100 (07/2011) FEATURES AND BENEFITS Application Environmentally friendly R410A refrigerant 3, 4, and 5 ton nominal capacities Multi-position applications

More information

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING PTG-C-1108

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING PTG-C-1108 DESCRIPTION ACP packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. SINGLE PACKAGE GAS/ELECTRIC

More information

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: 15SEERSplitHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR CASED/UNCASED COILS FOR GAS FURNACES: (-)CF: featuring Industry-Standard R-410A (-)CF: Refrigerant efrigerant WARNING! WARNING These instructions are intended as an aid to

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2005 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CB29M & CB30M Elite Series Units MULTI POSITION BLOWER COILS 504,79M 09/05 Supersedes 04/05 Litho U.S.A. RETAIN THESE INSTRUCTIONS

More information

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY PRODUCT SPECIFICATIONS STANDARD AIR HANDLER FORM NO. -100 (05/2014) APPLICATION 1 1/2-5 ton systems Upflow and horizontal (counterflow capable with kits) Sequenced for demand management External access

More information

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal

More information

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Submittal Data Form Job Name DCG Series 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Cooling Capacity: 88,000 144,000 BTU/h Heating Capacity (Output): 168,000 BTU/h Purchaser Order No.

More information

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES PRODUCT SPECIFICATIONS 4 SEER HEAT PUMP PACKAGED UNIT FORM NO. -00 (03/207) REFRIGERANT SYSTEM Environmentally friendly R40A refrigerant Copper tubing with enhanced fin coils Internal service gauge ports

More information

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS 07---25 SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz Product Data 07-12 16-25 C10887 Carrier s versatile packaged heat pump air-handling units satisfy design requirements

More information

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION

TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE DESCRIPTION Heating TECHNICAL GUIDE MODELS: P*HM, P*DH, P*LB OIL-FIRED WARM AIR UPFLOW / HORIZONTAL, DOWNFLOW / HORIZONTAL AND LOWBOY FURNACES 80 AFUE NATURAL GAS 58-188 MBH OUTPUT Air Conditioning R DESCRIPTION This

More information

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: PH13PA 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory

More information

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls. RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

SUNLINE 2000 (WORLD 50 HZ)

SUNLINE 2000 (WORLD 50 HZ) 530.26-TG1YI (298) SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS D3CE 036, 048, 060 & 076 D5CG 036, 048, 060 & 076 3, 4, 5 AND 6 NOMINAL TONS SHOWN SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION YORK Sunline 2000

More information

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician: START-UP INSTRUCTION OPTIMUM 36000 To 72000 BTU S PACKAGE UNITS 3 To 6 Ton START-UP CHECKLIST Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

More information

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ooling apacities:,000 to 57,500 BTU/h Heating apacities: 40,000 to 10,000 BTU/h GPG14M - to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ontents Nomenclature... Product Specifications... Expanded

More information

AWUF Series. Wall-Mount Air Handler 1½- to 3-Tons

AWUF Series. Wall-Mount Air Handler 1½- to 3-Tons Series Wall-Mount Air Handler 1½- to 3-Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Equipped with a check flowrater for cooling-only and heat pump operation Direct-drive, multi-speed

More information

Illusion Split System

Illusion Split System Illusion Split System Split System Air Conditioning (Concealed Type) -5 Ton - 50 Hz - R 22 Indoor Units MCD52DB MCD58DB MCD524DB MCD530DB MCD536DB MCD048DB MCD060DB Outdoor Units 2TTB052AA000D 2TTB058AA000D

More information

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT NXA6 Performance Series Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

FEM, FSM, FSU. Product Specifications

FEM, FSM, FSU. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS ALL MODELS 1½ thru 5 tons Available for R 22 or Environmentally Sound R 410A systems TXV metering device factory installed Copper tube / aluminum fin coil Sweat

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

JS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

JS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity TECHNICAL SPECIFICATIONS JS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The JS5BD Series of air conditioners offers exceptional performance. The unit, when

More information

PACKAGE HEAT PUMP UNITS

PACKAGE HEAT PUMP UNITS PACKAGE HEAT PUMP UNITS FOM NO. PTZ-77 EV. Supersedes Form No. PTZ-77 ev. 2 Featuring Earth-Friendly -40A efrigerant earth friendly refrigerant TZCHC- SEE HIGH EFFICIENCY SEIES NOMINAL SIZES -5 TONS [0.6-7.6

More information

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TABLE OF CONTENTS NOMENCLATURE............................. 3 FEATURES.................................... 4 KV SERIES FEATURES.........................

More information

FCX TECHNICAL BOOKLET

FCX TECHNICAL BOOKLET FAN COIL FCX US FCX USPO This document is based on AERMEC s FCX US, USP, USPO Technical and Installa on Booklet but reflects only those sizes and configura ons currently offered by Phoenix Energy Supply.

More information

Direct Drive Fluid Coolers Catalog 607. Type AFS 005 through AFS 107 Type AFD 046 through AFD 212

Direct Drive Fluid Coolers Catalog 607. Type AFS 005 through AFS 107 Type AFD 046 through AFD 212 Direct Drive Fluid Coolers Catalog 607 Type AFS 005 through AFS 107 Type AFD 046 through AFD 212 Table of Contents Introduction...3 Product Offering...3 Design Features...4 Selection Procedure...6 Application

More information

10+ SEER - AIR CONDITIONER

10+ SEER - AIR CONDITIONER 10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser

More information

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER High-Efficiency, R-410A 1½ to 5 Tons Cooling Capacity: 18,000 to 57,600 BTU/h Split System Heat Pump up to 14 SEER Heating Capacity: 18,000 to 59,000 BTU/h Standard Features R-410A chlorine-free refrigerant

More information

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Split System Heat Pump Up to 16 SEER & 9.5 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

Product Data. Features/Benefits. 30GTN,GTR Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz

Product Data. Features/Benefits. 30GTN,GTR Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz Product Data Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz Nominal Capacities: 36 to 410 Tons 127 to 1445 Features/Benefits ComfortLink control Your link to a world of simple

More information

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 8 MBH TO 4000 MBH TAbLE Of CONTENTs NOMENCLATURE............................. 3 features.................................... 4 KV series features.........................

More information

VS4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner. 14 SEER Residential System 1.

VS4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner. 14 SEER Residential System 1. TECHNICAL SPECIFICATIONS VS4BE Series R-410A High Efficiency Air Conditioner 14 SEER Residential System 1.5 5 Ton Capacity The VS4BE Series now offers the choice of an air conditioner that uses a more

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACX MERIT Series R-410A Bulletin 210739 November 2017 Supersedes August 2017 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh MODEL NUMBER

More information

COMMERCIAL WALK-IN COOLERS AND FREEZERS

COMMERCIAL WALK-IN COOLERS AND FREEZERS COMMERCIAL WALK-IN COOLERS AND FREEZERS LSA Models Ideal for coolers above +34 F Low Silhouette, draw through, high velocity units Capacity from 4,500 to 39,000 Btu/hr./10 F TD LSE, LSR and LST Models

More information

Packaged Gas/Electric Rooftop Units

Packaged Gas/Electric Rooftop Units Packaged Gas/Electric Rooftop Units Precedent YSC060-120 50 Hz February 2004 Introduction Precedent... The same Trane quality... with added flexibility. Precedent is a flexible line of packaged units that

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

Product Data. 40RM/RMS Packaged Air-Handling Units 50/60 Hz 6 to 30 Nominal Tons (21 to 105 kw) 40RM007S-012S 40RMS008S-012S

Product Data. 40RM/RMS Packaged Air-Handling Units 50/60 Hz 6 to 30 Nominal Tons (21 to 105 kw) 40RM007S-012S 40RMS008S-012S /RMS Packaged Air-Handling Units 50/60 Hz 6 to 30 Nominal Tons (21 to 105 kw) Product Data S-012S SS-012S 014S-034S S014S-034S Features / Benefits Multiposition design can be installed horizontally or

More information

T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ

T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ PRODUCT SPECIFICATIONS AIR HANDLERS TA T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ Bulletin No. TAA-07-40 (05/015) 180-40 Models 07-090-10-150 Models Nominal Capacity - 6 to 0 Tons Optional

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H3CE150, H4CE180 AND H3CE A-0402

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H3CE150, H4CE180 AND H3CE A-0402 TECHNICAL GUIDE SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H3CE150, H4CE180 AND H3CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped

More information

RGMA Series Package Gas Electric SPECIFICATIONS

RGMA Series Package Gas Electric SPECIFICATIONS RGMA Series Package Gas Electric SPECIFICATIONS CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC COMMERCIAL GAS/ELECTRIC UNIT FEATURES EFFICIENCY 7-1/2 thru 20 ton Cooling, 200,000 thru 270,000 BTUH Heating SINGLE

More information

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h D ommercial 3- to 6-Ton Packaged Air onditioner 13 SEE / Up to 11.3 EE ooling apacity: 34,600 71,000 BTU/h ontents Nomenclature... Product Specifications... 3 Expanded ooling Data... 7 Airflow Data...

More information

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS GR4GN Series Single Packaged Gas/Electric Units GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units The GR4GN is designed specifically for retrofit applications and compatibility

More information

VT4BF-KA/B Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton Capacity

VT4BF-KA/B Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton Capacity TECHNICAL SPECIFICATIONS VT4BF-KA/B Series Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton The VT4BF-KA/B series now offers the choice of a heat pump that uses a more efficient and environmentally

More information

CKL SERIES 10 SEER PRODUCT SPECIFICATIONS. Split System Air Conditioner. 1½ to 5 Ton

CKL SERIES 10 SEER PRODUCT SPECIFICATIONS. Split System Air Conditioner. 1½ to 5 Ton CKL SERIES 10 SEER Split System Air Conditioner 1½ to 5 Ton The CKL split system air conditioner is designed for ground-level or rooftop mount application. Standard Features Hermetically sealed compressor

More information

SDL Single-Duct, Low-Height, VAV Terminals

SDL Single-Duct, Low-Height, VAV Terminals SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely

More information

MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS

MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS ENGINEERING DATA Direct Drive Fan CONDENSING UNITS 13ACC MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS 1.5 to 5 Ton SEER up to 14.80 Net Capacity 18,300 to 61,000 Heavy Duty Louvered Steel Fan Guard Bulletin

More information

MEDIUM PROFILE UNIT COOLERS Technical Guide

MEDIUM PROFILE UNIT COOLERS Technical Guide BN-MPTB August 2016 Replaces BN-MPTB, June 2015 MEDIUM PROFILE UNIT COOLERS Technical Guide s BMA Air Defrost BME/BML Electric Defrost BMG/BMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-RLX-0817C Next-Gen All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Cooler and Freezer Applications Air Defrost 4,100 to 45,900 BTUH Electric Defrost 2,700 to 33,000 BTUH Defrost

More information

Predator Model Number Nomenclature

Predator Model Number Nomenclature DM, DH 6.5, 7.5, 8.5, 10.0, 12.5 Ton Single Package Air Conditioner HVAC SERVICE PARTS Supersedes: 035-17288-000 Rev A (800) 035-17288-001-A-0804 Predator Model Number Nomenclature 1 of 16 D H 120 N 20

More information

S-CLASS SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ

S-CLASS SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ AIR CONDITIONERS SSB S-CLASS SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ Bulletin 210466 November 2017 P R O D U C T S P E C I F I C AT I O N S Supersedes August 2017 S up to 16.50 3 to 5 Tons Cooling

More information

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11. PG ommercial ooling apacity: 90,000 8,000 BTU/h Heating apacity: 68,000 BTU/h Three-Phase 7½- to 2½-Ton Self-ontained Packaged Gas/Electric Units up to.5 EER 80% AFUE Standard Features R-40A chlorine-free

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

PGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT. PGF = Standard Models PGC = California Models with NOX baffles

PGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT. PGF = Standard Models PGC = California Models with NOX baffles PGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF = Standard Models PGC = California Models with NOX baffles C 1-1/2 THRU 5 TON, SINGLE PHASE Efficiency: PGF / PGC - 10 SEER. Combination

More information

DAVE LENNOX SIGNATURE COLLECTION

DAVE LENNOX SIGNATURE COLLECTION ENGINEERING DATA Heavy gauge steel cabinet with powder paint finish Defrost Control HEAT PUMP OUTDOOR UNITS HPXA15 2 to 5 Ton (5.3 to 17.6 ) SEER up to 14.75 Capacity 23,800 to 56,000 Btuh (7.0 to 16.4

More information

High Cap. (Btuh) HSPF COP

High Cap. (Btuh) HSPF COP RHS Product Specifications PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP 3 12.5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE R 410A HFC refrigerant ASHRAE 90.1 Energy Compliant

More information

FEATURES. a coil in horizontal position) Three speed PSC blower motor. Accessory Heater. Designed for 208/240 Volt. Single & Three phase models

FEATURES. a coil in horizontal position) Three speed PSC blower motor. Accessory Heater. Designed for 208/240 Volt. Single & Three phase models ELECTRIC FURNACE 2 THRU 5 TONS SPLIT SYSTEM EF Series FEATURES Electric Furnace, Air Conditioning or Heat Pump ready Upflow or horizontal left or right airflow as shipped. (Horizontal Drain Pan Accessory

More information

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506 TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & 060 3, 4 & 5 NOMINAL TONS 10.0 SEER DESCRIPTION BCB Series heat pumps are convertible single package units with a common cabinet and a common

More information

Unit Dimensions UNIT. Unit Dimensions UNIT

Unit Dimensions UNIT. Unit Dimensions UNIT RAS Product Specifications ELECTRIC COOLING, R410A SINGLE PACKAGE ROOFTOP 3 15 TONS (1 & 3Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE Onepiece, high efficiency electric cooling with a low profile,

More information

CAPACITY BTU/H FAN DATA MOTORS 240V AMPS

CAPACITY BTU/H FAN DATA MOTORS 240V AMPS LP Series Cooler above 34 F AIR DEFROST CAPACITY BTU/H 10 FTD 15 FTD QTY CFM MOTORS R-404A CHARGE LPA-18-0380 3850 5775 1 940 2 0.72 32 LPA-18-0520 5200 7800 1 900 2 1.09 34 LPA-18-0610 6100 9150 1 860

More information

TOTALINE REFRIGERATION CONDENSERS

TOTALINE REFRIGERATION CONDENSERS TOTALINE REFRIGERATION CONDENSERS P703 AIR-COOLED CONDENSERS AND DRY COOLERS Totaline s refrigeration condensers are used for refrigeration systems. These condensers are designed for large coolers or freezers.

More information

AIR COOLED CHILLERS WATER COOLED CHILLERS

AIR COOLED CHILLERS WATER COOLED CHILLERS AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with

More information

Comfort. Productivity Through. Commercial Coolers. Maximum Efficiency Evaporative Air Cooling

Comfort. Productivity Through. Commercial Coolers. Maximum Efficiency Evaporative Air Cooling www.evapcool.com Productivity Through Comfort Maximum Efficiency Evaporative Air Cooling To meet today s growing demand for increased productivity and serviceability, PMI has designed and offers the AeroCool

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PPG1GD Series M1010 Product Line Single Packaged Gas/Electric Units 13 SEER 2-5 Ton Units 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY PROMISE The PPG1GD

More information

EVAPORATOR PRESSURE REGULATORS

EVAPORATOR PRESSURE REGULATORS PARKER (S)PORT, (S)PORT II FEATURES AND BENEFITS Highest capacity commercial regulator in the industry. Sweat-in-place without disassembly. Interchangeable capacity cartridges. Low pressure drop. Manual

More information

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons Product Data 38HDL018-060 Cooling Only Condensing Unit 1 1 / 2 to 5 Nominal Tons The 38HDL energy-efficient condensing unit incorporates innovative technology to provide reliable cooling performance. Built

More information

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions PHH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE HEAT PUMP UNITS R 22, SINGLE PACKAGE ROOFTOP, 3 15 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency heat

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h ooling apacity: 4,000-59,000 BTU/h GP13H - to 5-Ton Packaged Air onditioner 13 SEER / R-410A Standard Features Energy-efficient compressor with internal relief valve PS blower motor; EEM blower motor on

More information

FCVC Series VERTICAL FAN COILS

FCVC Series VERTICAL FAN COILS VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information