BUILD YOUR REPUTATION ON OURS. Horizontal Series FAN COIL TECHNICAL CATALOG

Size: px
Start display at page:

Download "BUILD YOUR REPUTATION ON OURS. Horizontal Series FAN COIL TECHNICAL CATALOG"

Transcription

1 BUILD YOUR REPUTATION ON OURS Horizontal Series FAN COIL TECHNICAL CATALOG

2 TABLE OF CONTENTS 2 Table of Contents 3-4 Portfolio 5 Features & Benefits Unit Model Key 7 Ratings & Listings 8 Air Delivery 9 Sound Data 0-3 Fan Performance Curves 4 Electric Heating 5 Motor Data -25 Physical Data 2-30 Standard Features & Options 3 Piping Packages (Typical) International Environmental Corporation (IEC) works continually to improve its products. As a result, the design and specifications of each product may be changed without notice and may not be as described herein. Please contact IEC for information regarding current design and product specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties but are merely IEC s opinion or commendation of its products. Manufacturer s standard limited warranty applies. 2

3 PORTFOLIO CHY - Horizontal Hideaway 200 CFM to 200 CFM The Horizontal Hideaway (CHY) fan coil unit is designed specifically to meet the many varied requirements for a ceiling hideaway installation. The low-silhouette styling of the CHY makes this unit ideally suited for drop-ceiling and over-closet applications. Standard CHY units are provided with a galvanized finish. CBY - Horizontal Telescoping Hideaway 200 CFM to 200 CFM The Horizontal Telescoping Hideaway (CBY) fan coil unit is mounted fully-recessed for ceiling-recessed applications. The CBY s telescoping frame with hinged panel adapts to any ceiling type and ensures exact alignment of the panel with the ceiling. The hinged-bottom panel provides easy access to all internal components. Standard CBY units are provided with a galvanized finish on the cabinet and powder-coat paint finish on the bottom-access panel. 3

4 PORTFOLIO, Cont d. CPY - Horizontal Hideaway with Plenum 200 CFM to 200 CFM The Horizontal Hideaway with Plenum (CPY) fan coil unit provides the same basic features of the CHY plus a return air plenum for above-ceiling mounting in closets, hallways or bathroom areas. The CPY design enables the unit to be adapted to installations requiring return air ducts or to be used as a return-air plenum with a unit-mounted filter and filter-rack assembly. CPY units are shipped from the factory ready for installation with the plenum section in place. No field fabrication is required. CPY units are designed with interchangeable panels so that the unit may be modified on site to accommodate a rear or bottom return. Standard CPY units are provided with a galvanized finish. CXB - Horizontal Cabinet 200 CFM to 200 CFM The Horizontal Cabinet (CXB) fan coil unit is designed specifically for exposed mounting in hotels, motels, hospitals, nursing homes, offices or other commercial establishments. With the CXB, valuable floor space is not required, and its slim, attractively-styled cabinet blends with all types of decor. Since there is no requirement for duct work or structure modifications, the CXB is ideal for retrofit applications. Standard CXB units are provided with a powder-coat paint finish. 4

5 FEATURES & BENEFITS Application Fit Multiple cabinet choices are available in 7 nominal CFM sizes for application in a variety of room layouts. o Horizontal Cabinet units (CXB) with aesthetically pleasing cabinetry offer capacities that are ideal for air conditioning in dormitories, small apartments, schools and many other applications. Front supply, bottom or rear return are available. o Horizontal Telescoping Hideaway units with painted access panel (CBY) allows smooth fit up to plaster or sheet rock ceilings. Standard units include bottom louvered return air with the filter located in the access panel. o Horizontal Hideaway models (CHY) units are installed above the ceiling with or without ducted supply air and open soffit return with an optional ceiling-mounted filter-grille. o Horizontal Hideaway models with plenum (CPY) units are installed above the ceiling with or without ducted supply air and ducted return air. The return air filter is either mounted on the unit plenum or installed in an optional ceiling filtergrille. Design Flexibility Easy to use ratings program to speed up project design. Standard and high capacity hydronic coils and DX coils are available to match the heating and cooling loads of the space. Optional powder-paint finish colors and grille selections will complement most décors (exposed units). CXB and CBY units ordered with optional rear return are constructed with a solid bottom panel. Customizable cabinetry makes these units ideal for renovation jobs or where special sizes are required to fit oversized valves and control packages. Optional airflow configuration (front supply, bottom supply, rear return or bottom return) to meet certain design limitations. Outside air connections are available to meet ventilation requirements and reduce field labor (CXB/ CBY/CPY). Wide variety of factory assembled valve packages to meet desired controls specifications. Optional condensate overflow switch to address latest building codes where required. Wide variety of optional insulation materials are available to address IAQ concerns. Ease of Installation Factory assembled valve packages minimize piping work at the job site (shipped loose for field mounting). Optional unit mounted controls, service switches and fusing minimize the electrical work required on site. Units are tagged at the factory for clear identification on job site. Opposite end connection units may minimize the piping work on renovation jobs. Ease of Service All components are accessible by simply removing the access panel. Filters can be replaced without tools or by opening the bottom panels on exposed units. Blower assembly easily removed from the rear of coil for service and cleaning. Quality and Safety Every unit is tested and inspected at the factory for trouble free start-up. ETL and CETL listed. AHRI certified. 5

6 UNIT MODEL KEY Code Items Code 0 C B 02 Y A 04 Y Y Y C 04a B Y Y 05 C 2 0 R 5 C 07 P B UNIT VINTAGE SIZE COILS ELECTRIC HEAT MOTOR HAND/ ARRANGEMENT CONTROLS CHY CPY CBY CXB Horizontal Hideaway Horizontal Hideaway with Plenum Horizontal Telescoping Hideaway Horizontal Cabinet CFM CFM CFM 0 00 CFM CFM CFM CFM Voltage C 5--0 D E F V * U * Type 2 Permanent Split Capacitor A ECM, 3-Spd Relay Brd (L/M/H) B ECM, Proportional (0-0VDC) C ECM, 4-Spd EVO Board, Solid State w/pwm Two-pipe Cooling and Heating or Four-pipe Cooling A 3 Row R 3 Row, AAV B 4 Row S 4 Row, AAV D 2 Row Four-pipe Heating Y None Row 7 2 Row Coil Connection Y None S Same End O Opposite End Coil Construction Y Std S SS Wrapper Hand*** R Right L Left Arrangement 5 CHY, BHY Voltage kw** Stages C 20 V D 208 V E 240 V F 277 V V 220 V (50)* U 240 V (50)* Y None AY 0.50 HY 5.00 BY.00 JY.00 CY.50 KY 7.00 DY 2.00 LY 8.00 FY 3.00 NY 0.00 GY 4.00 YY None Y Single Stage Only 5 5 CPY, BPY CBY CXB 5 Voltage B 24 V C 20 V D 208 V E 240 V F 277 V V 220 V (50)* U 240 V (50)* * Consult factory for 50Hz applications. ** Note that kws depend on voltage and unit size. System Manual Fan Operation A Standard Wall Mount (Switch Only) Function Control G 2 Pipe Heat Only H 2 Pipe Cool Only K 2 Pipe Heat and Cool M 2 Pipe Heat and Cool w/aux. Elec. Heat P 2 Pipe Cool Only w/total Elec. Heat R 4 Pipe Heat and Cool Thermostat A TB55 Wall Series, ACO, Vertical Mnt. B TB55 Wall Series, ACO, Horizontal Mtd. P Basic 24V Digital Programmable, ACO N Basic 24V Non-Programmable, ACO F Premium 24V Digital 7-Day Programmable, with Proportional Fan/Valves Option, ACO G Premium 24 Digital BACnet with Proportional Fan/Valves Option, ACO

7 RATINGS & LISTINGS AHRI Certification IEC s Horizontal Series units are certified in compliance with Air-Conditioning, Heating, and Refrigeration Institute (AHRI) industry standard AHRI-440 for room fan coil units. Approved standard ratings are tabulated below. C-ETL US Listing IEC s Horizontal Series units are listed by ETL. The C-ETL-US listing signifies that IEC s fan coil units have been examined by ETL and are in compliance with both the U.S. and Canadian applicable standards HEATING AND COOLING EQUIPMENT Standard Ratings Unit Type CHY CPY CXB CBY CHY CPY CXB CBY Unit Cell Size Nominal CFM Cooling Capacity Total MBH Sensible MBH Power Input Watts PSC 02-A A A A A A A B B B B B B B NOTES:. Ratings are based on 80 F DB and 7 F WB EAT, 45 F EWT, 0 F water temperature rise, high fan speed, motor voltage 5//0, and air flow under dry coil conditions. 2. For all application ratings, use IEC s computer selection program, the quick-selection ratings provided in this catalog, or contact your local IEC representative. 3. For additional information, please consult AHRI s website at 7

8 DELIVERY Air Delivery (0 Hz) Model CHY CPY CBY CXB Coil 3 Row 4 Row 3 Row 4 Row 3 Row 4 Row 3 Row 4 Row Unit CFM@ 0.0 ESP - For Fan Speed High Speed ESP Indicated Size Low Med High NOTES:. Tabled values are standard CFM at sea level, 70 F with dry coil. 2. Ratings include factory-installed filter and/or grille, where applicable. 3. Consult factory for 50 Hz applications. 8

9 SOUND DATA Sound Data UNIT SIZE RATING CASING RADIATED DUCTED DISCHARGE CASING RADIATED DUCTED DISCHARGE CASING RADIATED DUCTED DISCHARGE CASING RADIATED DUCTED DISCHARGE CASING RADIATED DUCTED DISCHARGE CASING RADIATED DUCTED DISCHARGE CASING RADIATED DUCTED DISCHARGE FAN SPEED CFM SOUND POWER LEVEL, Lw (db one reference pico watt) 25 Hz 250 Hz 500 Hz K Hz 2K Hz 4K Hz 8K Hz H M L H M L H M L H M L H M L H M L H M L H M L H M L H M L H M L H M L H M L H M A-wgt (dba) L

10 FAN PERFORMANCE CURVES 0.5 Unit Size 02 - CPY ESP (in.w.c.) High Med Low SCFM PSC Motor Fan Curve: - 3-Row 5-Row ECM Operating Range: 4-Row 0.5 Unit Size 03 - CPY ESP (in.w.c.) High Med 0.5 Low SCFM PSC Motor Fan Curve: 3-Row 5-Row ECM Operating Range: 4-Row 0

11 FAN PERFORMANCE CURVES, Cont d. 0.5 Unit Size 04 - CPY High ESP (in.w.c.) Med 0.5 Low SCFM PSC Motor Fan Curve: - 3-Row 5-Row ECM Operating Range: 4-Row 0.5 Unit Size 0 - CPY High ESP (in.w.c.) Low Med SCFM PSC Motor Fan Curve: 3-Row 5-Row 4-Row ECM Operating Range:

12 FAN PERFORMANCE CURVES, Cont d. 0.5 Unit Size 08 - CPY High ESP (in.w.c.) Low Med SCFM PSC Motor Fan Curve: - 3-Row 5-Row 4-Row ECM Operating Range: 0.5 Unit Size 0 - CPY High ESP (in.w.c.) Low Med SCFM PSC Motor Fan Curve: - 3-Row 5-Row 4-Row ECM Operating Range: 2

13 FAN PERFORMANCE CURVES, CONT D. 0.5 Unit Size 2 - CPY High ESP (in.w.c.) Med 0.5 Low SCFM PSC Motor Fan Curve: 3-Row - 5-Row 4-Row ECM Operating Range: 3

14 ELECTRIC HEATING Electric Resistance Heating Electric heaters are available on IEC Horizontal Series fan coil units for the following applications. Total Electric Heat Total electric heat eliminates the requirement for a boiler. Heating and/or cooling may be available on an individual basis throughout the year. Two-pipe chilled water is used for cooling; and the electric heater is used for heating. Individual room controls can be supplied for either manual or automatic changeover. Auxiliary Electric Heat Auxiliary electric heat is ideal for tempering room air between seasons and during the cooling season when chilled water is being circulated. Individual room controls are supplied to provide electric heat only when chilled water is being circulated. During regular heating season, heating is provided by hot water being circulated in the system. Construction The heater coils of high-grade resistance wire are supported by ceramic insulators on plated steel brackets. These heat elements are suspended directly in front of the fan outlet between the blower and the coil. High limit thermal cutouts protect the heater in the event of air failure. There are many special applications and control sequences for electric heat. For special applications, please consult the factory. Electric Heater Selection Voltage 20 V 208 V 240 V 277 V kw Unit Size Note Note Note Note Note Note Note Note Note Note Note NOTES:. All heaters are single stage and single phase. 2. Heaters over 48 Amps are subdivided and fused. 3. Electric Heating Capacities (BTUH) = Heater kw x Electric Heater Amperage = (Heater kw x 000)/Applied Voltage) 5. Consult factory for 50 Hz applications.. High and medium speed only. 4

15 MOTOR DATA Thermal Overload Protection and ETL Listing All permanently lubricated split-capacitor motors furnished by IEC contain internal thermaloverload protection. The overload automatically resets when the temperature returns to a safe limit. Electronics Testing Laboratories, Inc. approves the motor and thermal overload combination at locked rotor conditions only. Motor Performance Data - CHY, CPY, CXB, CBY Unit Size Voltage Fan Speed Nominal /30 /30 /2 /2 / (2) /2 (2) / HP Amps High Watts V Amps Hz Medium Watts Phase Amps Low Watts Amps High Watts V Amps Hz Medium Watts Phase Amps Low Watts Amps High Watts V Amps Hz Medium Watts Phase Amps Low Watts Amps High Watts V Amps Hz Medium Watts Phase Amps Low Watts NOTES:. Total unit motor Amps and Watts are shown. 2. Consult factory for 50 Hz applications. 5

16 PHYSICAL DATA CHY - Horizontal Hideaway 4 (02) 4 (02) JUNCTION BOX (REMOTE MOUNT) FLEXIBLE METAL CONDUIT - SEE DIMENSION "J" UNIT LABEL AND WIRING DIAGRAM (SEE NOTE ) 7/8 (22) O.D. CONDENSATE DRAIN 5/8 () O.D. TELL-TALE DRAIN CONNECTION, AVAILABLE ON STANDARD AND EXTENDED DRAIN PANS 2 (5) (52) 7-/3 (87) -/8 (29) 2-/4 (57) E MTG. HOLES B A 3 (7) RESILIENT MOUNTING GROMMET W/ 3/8 (0) DIA. HOLES (TYP. OF 4) A' D' EXTENDED DRAIN PAN TOP VIEW 3/4 (9) TYP H CHILLED/HOT WATER SUPPLY & RETURN CONNECTIONS (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) " SUPPLY DUCT COLLAR 7/8 (22) G F SUPPLY 8-3/8 (23) 7-/2 (445) VENT FRONT VIEW (40) DRIP LIP SHIPPED LOOSE (NOTE 4) RIGHT SIDE VIEW Unit Model Dimensions - Inches (Millimeters) Quantity/Unit Unit Weight* A A B D E F G H J Blower Motor CHY02 2-/4 (540) 3-/4 (794) (40) 3 (330) 8-/4 (44) -/4 (59) 8-3/4 (222) 9-3/4 (502) 38 (95) 3 CHY03 25-/4 (4) 3-/4 (92) 20 (508) 4 (35) 22-/4 (55) -/4 (59) 8-3/4 (222) 23-3/4 (03) 38 (95) 39 CHY04 3-/4 (794) 43-/4 (099) 2 (0) 5 (38) 28-/4 (78) -/4 (59) 8-3/4 (222) 29-3/4 (75) 38 (95) 2 49 CHY0 3-/4 (92) 43-/4 (099) 3 (787) 0 (254) 33-/4 (845) 7-/2 (9) 0 (254) 34-3/4 (883) 38 (95) 2 59 CHY08 43-/4 (099) 57-/4 (454) 38 (95) 7 (432) 40-/4 (022) 7-/2 (9) 0 (254) 4-3/4 (00) 38 (95) 2 4 CHY0 57-/4 (454) 5-/4 (57) 52 (32) (279) 54-/4 (378) 7-/2 (9) 0 (254) 55-3/4 (4) 0 (524) CHY2 5-/4 (57) 75-/4 (9) 0 (524) 3 (330) 2-/4 (58) 7-/2 (9) 0 (254) 3-3/4 (9) 5 (5) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Optional drip lip not required with optional extended drain pan. 3. All dimensions are +/- /4" (). 4. Drip lip recommended. 5. Product specifications are subject to change without notice.. Control box size and position may vary (consult factory). 7. Dimension G represents maximum on lowest end of sloped drain pan. 8. Threaded fittings must be field tightened and leak tested. Drawing is not to scale and is provided for reference only. Dimensions may vary with options ordered. Consult IEC web site for up to date drawings.

17 PHYSICAL DATA, Cont d. CHY - Horizontal Hideaway with Electric Heat CONTROL BOX (REMOTE MOUNT) (52) STD. 5-3/8 (37) STD. FLEXIBLE METAL CONDUIT - SEE DIMENSION "J" UNIT LABEL AND WIRING DIAGRAM (SEE NOTE ) STRIP HEATER HIGH LIMIT ELECTRIC STRIP HEATER ELEMENT 5/8 () O.D. TELL-TALE DRAIN CONNECTION, AVAILABLE ON STANDARD AND EXTENDED DRAIN PANS 2 (5) (52) 7/8 (22) O.D. CONDENSATE DRAIN 7-/3 (87) -/8 (29) 2-/4 (4) E MTG. HOLES B 3 (7) RESILIENT MOUNTING GROMMET W/ 3/8 (0) DIA. HOLES (TYP. OF 4) A' D' EXTENDED DRAIN PAN A TOP VIEW 3/4 (9) TYP H FRONT VIEW (40) CHILLED/HOT WATER SUPPLY & RETURN CONNECTIONS (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) DRIP LIP SHIPPED LOOSE (NOTE 4) " SUPPLY DUCT COLLAR 7/8 (22) G F SUPPLY 2-3/8 (34) 2 (54) VENT RIGHT SIDE VIEW Unit Model Dimensions - Inches (Millimeters) Quantity/Unit Unit Weight* A A B D E F G H J Blower Motor CHY02 2-/4 (540) 3-/4 (794) (40) 3 (330) 8-/4 (44) -/4 (59) 8-3/4 (222) 9-3/4 (502) 38 (95) 38 CHY03 25-/4 (4) 3-/4 (92) 20 (508) 4 (35) 22-/4 (55) -/4 (59) 8-3/4 (222) 23-3/4 (03) 38 (95) 4 CHY04 3-/4 (794) 43-/4 (099) 2 (0) 5 (38) 28-/4 (78) -/4 (59) 8-3/4 (222) 29-3/4 (75) 38 (95) 2 5 CHY0 3-/4 (92) 43-/4 (099) 3 (787) 0 (254) 33-/4 (845) 7-/2 (9) 0 (254) 34-3/4 (883) 38 (95) 2 CHY08 43-/4 (099) 57-/4 (454) 38 (95) 7 (432) 40-/4 (022) 7-/2 (9) 0 (254) 4-3/4 (00) 38 (95) 2 CHY0 57-/4 (454) 5-/4 (57) 52 (32) (279) 54-/4 (378) 7-/2 (9) 0 (254) 55-3/4 (4) 0 (524) CHY2 5-/4 (57) 75-/4 (9) 0 (524) 3 (330) 2-/4 (58) 7-/2 (9) 0 (254) 3-3/4 (9) 5 (5) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Optional drip lip not required with optional extended drain pan. 3. All dimensions are +/- /4" (). 4. Drip lip recommended. 5. Product specifications are subject to change without notice.. Control box size and position may vary (consult factory). Drawing is not to scale and is provided for 7. Threaded fittings must be field tightened and leak tested. reference only. Dimensions may vary with options ordered. Consult IEC web site for up to date drawings. 7

18 PHYSICAL DATA, Cont d. CPY - Horizontal Hideaway with Plenum INSULATED PLENUM 3 JUNCTION (7) BOX 3-/4 (83) 4 (02) 5-/4 (387) -/8 (29) 2-/4 (57) H REAR MTG. HOLES C MTG. HOLES B TOP VIEW UNIT LABEL AND WIRING DIAGRAM (SEE NOTE ) 3 (7) 7/8 (22) O.D. CONDENSATE DRAIN RESILIENT MOUNTING GROMMET W/ 3/8 (0) DIA. HOLES (TYP. OF 4) 5/8 () O.D. TELL-TALE DRAIN CONNECTION, AVAILABLE ON STANDARD AND EXTENDED DRAIN PANS A' D' 2 (5) 7-/3 (87) EXTENDED DRAIN PAN BOTTOM ACCESS PANEL FILTER REMOVAL " FILTER RETURN " RETURN DUCT COLLAR FILTER RETAINER CLIP REAR RETURN 3/4 (9) TYP 0-/2 (27) E A FRONT VIEW (40) CHILLED/HOT WATER SUPPLY & RETURN CONNECTIONS (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) DRIP LIP SHIPPED LOOSE (NOTE 4) " SUPPLY DUCT COLLAR 7/8 (22) G F SUPPLY " FILTER 20 (508) 9 (483) -3/8 (289) VENT RETURN RIGHT SIDE VIEW REAR ACCESS PANEL FILTER REMOVAL Unit Model Dimensions - Inches (Millimeters) Quantity/Unit Unit Weight* A A B C D E F G H Blower Motor CPY02 2-/4 (540) 3-/4 (794) (40) 8-/4 (44) 3 (330) 9-3/4 (502) -/4 (59) 8-3/4 (222) 5-3/8 (39) 55 CPY03 25-/4 (4) 3-/4 (92) 20 (508) 22-/4 (55) 4 (35) 23-3/4 (03) -/4 (59) 8-3/4 (222) 9-3/8 (883) 0 CPY04 3-/4 (794) 43-/4 (099) 2 (0) 28-/4 (78) 5 (38) 29-3/4 (75) -/4 (59) 8-3/4 (222) 25-3/8 (45) 2 70 CPY0 3-/4 (92) 43-/4 (099) 3 (787) 33-/4 (845) 0 (254) 34-3/4 (883) 7-/2 (90) 0 (254) 30-3/8 (772) 2 82 CPY08 43-/4 (099) 57-/4 (454) 38 (95) 40-/4 (022) 7 (432) 4-3/4 (00) 7-/2 (90) 0 (254) 37-3/8 (949) 2 95 CPY0 57-/4 (454) 5-/4 (57) 52 (32) 54-/4 (378) (279) 55-3/4 (4) 7-/2 (90) 0 (254) 5-3/8 (305) CPY2 5-/4 (57) 75-/4 (9) 0 (524) 2-/4 (58) 3 (330) 3-3/4 (9) 7-/2 (90) 0 (254) 59-3/8 (508) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Optional drip lip not required with optional extended drain pan. 3. All dimensions are +/- /4" (). 4. Drip lip recommended. 5. Product specifications are subject to change without notice. Drawing is not to scale and is provided for. Control box size and position may vary (consult factory). reference only. Dimensions may vary with 7. Threaded fittings must be field tightened and leak tested. options ordered. Consult IEC web site for up to date drawings. 8

19 PHYSICAL DATA, Cont d. CPY - Horizontal Hideaway with Plenum with Electric Heat 3-/4 (83) (52) STD. 9-/4 (489) CONTROL BOX 5-3/8 (37) STD. INSULATED PLENUM -/8 (29) C FRONT MTG. HOLES 2-/4 (57) B A H REAR MTG. HOLES TOP VIEW UNIT LABEL AND WIRING DIAGRAM (SEE NOTE 7) ELECTRIC STRIP HEATER ELEMENT 3 (7) 7/8 (22) O.D. CONDENSATION DRAIN STRIP HEATER HIGH LIMIT 5/8 () O.D. TELL-TALE DRAIN CONNECTION, AVAILABLE ON STANDARD AND EXTENDED DRAIN PANS A' D' 7-/3 (87) 2 (5) EXTENDED DRAIN PAN BOTTOM ACCESS PANEL " FILTER RETURN " RETURN DUCT COLLAR FILTER RETAINER CLIP FILTER REMOVAL REAR RETURN 0-/2 (27) 3/4 (9) 3/4 (9) TYP ELECTRICAL KNOCKOUTS IN TOP & BOTTOM OF CONTROL BOX RESILIENT MOUNTING GROMMET W/ 3/8 (0) DIA. HOLES (TYP. OF 4) FRONT VIEW (40) CHILLED/HOT WATER SUPPLY & RETURN CONNECTIONS (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) DRIP LIP SHIPPED LOOSE (NOTE 5) " SUPPLY DUCT COLLAR 7/8 (22) SUPPLY F G " FILTER 24 (0) 23 (584) VENT -3/8 (289) RETURN RIGHT SIDE VIEW REAR ACCESS PANEL FILTER REMOVAL Unit Model Dimensions - Inches (Millimeters) Quantity/Unit Unit Weight* A A B C D E F G H Blower Motor CPY02 2-/4 (540) 3-/4 (794) (40) 8-/4 (44) 3 (330) 9-3/4 (502) -/4 (59) 8-3/4 (222) 5-3/8 (39) 57 CPY03 25-/4 (4) 3-/4 (92) 20 (508) 22-/4 (55) 4 (35) 23-3/4 (03) -/4 (59) 8-3/4 (222) 9-3/8 (883) 2 CPY04 3-/4 (794) 43-/4 (099) 2 (0) 28-/4 (78) 5 (38) 29-3/4 (75) -/4 (59) 8-3/4 (222) 25-3/8 (45) 2 72 CPY0 3-/4 (92) 43-/4 (099) 3 (787) 33-/4 (845) 3 (330) 34-3/4 (883) 7-/2 (90) 0 (254) 30-3/8 (772) 2 84 CPY08 43-/4 (099) 57-/4 (454) 38 (95) 40-/4 (022) 7 (432) 4-3/4 (00) 7-/2 (90) 0 (254) 37-3/8 (949) 2 97 CPY0 57-/4 (454) 5-/4 (57) 52 (32) 54-/4 (378) (279) 55-3/4 (4) 7-/2 (90) 0 (254) 5-3/8 (305) CPY2 5-/4 (57) 75-/4 (9) 0 (524) 2-/4 (58) 3 (330) 3-3/4 (9) 7-/2 (90) 0 (254) 59-3/8 (508) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Optional drip lip not required with optional extended drain pan. 3. All dimensions are +/- /4" (). 4. Product specifications are subject to change without notice. 5. Drip lip recommended. Drawing is not to scale and is provided for. Threaded fittings must be field tightened and leak tested. reference only. Dimensions may vary with 7. Control box size and position may vary (consult factory). options ordered. Consult IEC web site for up to date drawings. 9

20 PHYSICAL DATA, Cont d. CBY - Horizontal Telescoping Hideaway 2 (0) 20-3/4 (527) -/8 (5) JUNCTION BOX E TOP VIEW UNIT LABEL AND WIRING DIAGRAM (SEE NOTE ) "L" SHAPED DRIP CHILLED/HOT WATER SUPPLY & RETURN CONNECTION (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) RESILIENT MOUNTING GROMMETS WITH 3/8 (0) DIA. HOLE (TYP. OF 4) 7/8 (22) KNOCKOUT PARTIAL REAR VIEW (TYPICAL BOTH SIDES) KNOCKOUT (TYPICAL) 24 (0) TYP A -/8 (5) B C -/4 (32) 20-3/4 (527) VENT DUCTED REAR RETURN -/4 2 (305) (28) MIN. 4 (35) MAX. D FRONT VIEW F " SUPPLY DUCT COLLAR SUPPLY 7/8 (22) O.D. CONDENSATE DRAIN CONNECTION RETURN RIGHT SIDE VIEW STAMPED RETURN (52) GRILLE & " FILTER HINGED BOTTOM RETURN PANEL Unit Model Dimensions - Inches (Millimeters) Quantity/Unit Unit Weight* A B C D E F Blower Motor CBY02 35 (889) (40) 2-3/4 (324) 37 (940) 32 (83) (52) 5 CBY03 35 (889) 20 (508) 8-3/4 (222) 37 (940) 32 (83) (52) 20 CBY04 4 (04) 2 (0) 8-3/4 (222) 43 (092) 38 (95) (52) 2 35 CBY0 53 (34) 3 (787) 5-3/4 (400) 55 (397) 50 (270) 7 (78) 2 50 CBY08 53 (34) 38 (95) 8-3/4 (222) 55 (397) 50 (270) 7 (78) 2 55 CBY0 75 (905) 52 (32) -3/4 (425) 77 (95) 72 (829) 7 (78) CBY2 75 (905) 0 (524) 8-3/4 (222) 77 (95) 72 (829) 7 (78) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Internal factory valve packages and drains may not align w/cabinet knockouts. 3. All dimensions are +/- /4" (). 4. Product specifications are subject to change without notice. 5. Drip lip required for units with valves. Drawing is not to scale and is provided for. Control box size and position may vary (consult factory). reference only. Dimensions may vary with 7. Threaded fittings must be field tightened and leak tested. options ordered. Consult IEC web site for up to date drawings. 20

21 PHYSICAL DATA, Cont d. CBY - Horizontal Telescoping Hideaway with Electric Heat 2 (0) 20-3/4 (527) CONTROL STRIP BOX A HEATER HIGH LIMIT UNIT LABEL AND WIRING DIAGRAM (SEE NOTE ) ELECTRIC STRIP HEATER ELEMENT "L" SHAPED DRIP LIP, SHIPPED LOOSE (NOTE 5) CHILLED/HOT WATER SUPPLY & RETURN CONNECTION (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) -/8 (5) E TOP VIEW RESILIENT MOUNTING GROMMETS WITH 3/8 (0) DIA. HOLE (TYP. OF 4) 7/8 (22) KNOCKOUT KNOCKOUT (TYPICAL) PARTIAL REAR VIEW (TYPICAL BOTH SIDES) TYP A -/8 (5) B C -/4 (32) 24 (0) 20-3/4 (527) VENT DUCTED REAR RETURN -/4 2(305) (28) MIN. 4(35) MAX. D FRONT VIEW " SUPPLY DUCT COLLAR SUPPLY F 7/8 (22) O.D. CONDENSATE DRAIN CONNECTION RIGHT SIDE VIEW (52) RETURN STAMPED HINGED BOTTOM RETURN RETURN GRILLE & PANEL " FILTER Unit Model Dimensions - Inches (Millimeters) Quantity/Unit Unit Weight* A B C D E F Blower Motor CBY02 35 (889) (40) 2-3/4 (324) 37 (940) 32 (83) (52) 7 CBY03 35 (889) 20 (508) 8-3/4 (222) 37 (940) 32 (83) (52) 22 CBY04 4 (04) 2 (0) 8-3/4 (222) 43 (092) 38 (95) (52) 2 37 CBY0 53 (34) 3 (787) 5-3/4 (400) 55 (397) 50 (270) 7 (78) 2 52 CBY08 53 (34) 38 (95) 8-3/4 (222) 55 (397) 50 (270) 7 (78) 2 57 CBY0 75 (905) 52 (32) -3/4 (425) 77 (95) 72 (829) 7 (78) CBY2 75 (905) 0 (524) 8-3/4 (222) 77 (95) 72 (829) 7 (78) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Optional drip lip not required with optional extended drain pan. 3. All dimensions are +/- /4" (). 4. Product specifications are subject to change without notice. 5. Drip lip required for units with valves. Drawing is not to scale and is provided for. Control box size and position may vary (consult factory). reference only. Dimensions may vary with 7. Threaded fittings must be field tightened and leak tested. options ordered. Consult IEC web site for up to date drawings. 2

22 PHYSICAL DATA, Cont d. CBY - Horizontal Telescoping Hideaway with Bottom Supply JUNCTION BOX UNIT LABEL AND WIRING DIAGRAM (SEE NOTE ) "L" SHAPED DRIP LIP, SHIPPED LOOSE (NOTE 5) 3 (94) 30-3/4 (78) CHILLED/HOT WATER SUPPLY & RETURN CONNECTION (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) TOP VIEW E RESILIENT MOUNTING GROMMETS WITH 3/8 (0) DIA. HOLE (TYP. OF 4) 7/8 (22) KNOCKOUT KNOCKOUT (TYPICAL) PARTIAL REAR VIEW (TYPICAL BOTH SIDES) A 30-3/4 (78) 34 (84) VENT DUCTED REAR RETURN -/4 (28) 2"(305) MIN. 4"(35) MAX. D FRONT VIEW STAMPED SUPPLY GRILLE SUPPLY (52) 7/8 (22) O.D. CONDENSATE DRAIN CONNECTION RETURN RIGHT SIDE VIEW (52) HINGED BOTTOM RETURN PANEL STAMPED RETURN GRILLE & " FILTER Unit Model Dimensions - Inches (Millimeters) Quantity/Unit A D E F Blower Motor Unit Weight* CBY02 35 (889) 37 (940) 32 (83) (52) 5 CBY03 35 (889) 37 (940) 32 (83) (52) 20 CBY04 4 (04) 43 (092) 38 (95) (52) 2 35 CBY0 53 (34) 55 (397) 50 (270) 7 (78) 2 50 CBY08 53 (34) 55 (397) 50 (270) 7 (78) 2 55 CBY0 75 (905) 77 (95) 72 (829) 7 (78) CBY2 75 (905) 77 (95) 72 (829) 7 (78) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Internal factory valve packages and drains may not align w/cabinet knockouts. 3. All dimensions are +/- /4" (). 4. Product specifications are subject to change without notice. 5. Drip lip required for units with valves.. Control box size and position may vary (consult factory). Drawing is not to scale and is provided for 7. Threaded fittings must be field tightened and leak tested. reference only. Dimensions may vary with options ordered. Consult IEC web site for up to date drawings. 22

23 PHYSICAL DATA, Cont d. CBY - Horizontal Telescoping Hideaway with Bottom Supply with Electric Heat CONTROL BOX STRIP HEATER HIGH LIMIT UNIT LABEL AND WIRING DIAGRAM (SEE NOTE ) ELECTRIC STRIP HEATER ELEMENT "L" SHAPED DRIP LIP, SHIPPED LOOSE (NOTE 5) 30-3/4 3 (78) (94) E TOP VIEW CHILLED/HOT WATER SUPPLY & RETURN CONNECTION (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) RESILIENT MOUNTING GROMMETS WITH 3/8 (0) DIA. HOLE (TYP. OF 4) 7/8 (22) KNOCKOUT KNOCKOUT (TYPICAL) PARTIAL REAR VIEW (TYPICAL BOTH SIDES) 34 (84) TYP -/4 (28) 2"(305) MIN. 4"(35) MAX. A D FRONT VIEW STAMPED SUPPLY GRILLE SUPPLY (52) 30-3/4 (78) VENT 7/8 (22) O.D. CONDENSATE DRAIN CONNECTION RETURN RIGHT SIDE VIEW DUCTED REAR RETURN (52) HINGED BOTTOM RETURN PANEL STAMPED RETURN GRILLE & " FILTER Unit Model Dimensions - Inches (Millimeters) Quantity/Unit A D E Blower Motor Unit Weight* CBY02 35 (889) 37 (940) 32 (83) 7 CBY03 35 (889) 37 (940) 32 (83) 22 CBY04 4 (04) 43 (092) 38 (95) 2 37 CBY0 53 (34) 55 (397) 50 (270) 2 52 CBY08 53 (34) 55 (397) 50 (270) 2 57 CBY0 75 (905) 77 (95) 72 (829) CBY2 75 (905) 77 (95) 72 (829) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Internal factory valve packages and drains may not align w/cabinet knockouts. 3. All dimensions are +/- /4" (). 4. Product specifications are subject to change without notice. Drawing is not to scale and is provided for 5. Drip lip required for units with valves. reference only. Dimensions may vary with. Control box size and position may vary (consult factory). options ordered. Consult IEC web site for 7. Threaded fittings must be field tightened and leak tested. up to date drawings. 23

24 PHYSICAL DATA, CONT D. CXB - Horizontal Cabinet 3 /2 (89) JUNCTION BOX UNIT LABEL AND WIRING DIAGRAM (SEE NOTE ) STAMPED RETURN GRILLE & " FILTER 8 (457) "L" SHAPED DRIP LIP, SHIPPED LOOSE (NOTE 5) 7/8 (22) KNOCKOUT (TYP. OF 2) KNOCKOUT (TYP. OF 5) 2 (5) 2 (5) E A TOP VIEW CHILLED/HOT WATER SUPPLY & RETURN CONNECTIONS (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) 2 (5) PARTIAL REAR VIEW (TYPICAL BOTH SIDES) C B C VENT 23-/2 (597) 7/8" (22) O.D. CONDENSATE DRAIN CONNECTION F G SUPPLY RETURN 5-3/4 (4) LOCATION STANDARD STAMPED SUPPLY GRILLE FRONT VIEW RESILIENT MOUNTING GROMMETS WITH 3/8" (0) DIA. HOLE (TYP. OF 4) APPROX. 2 REF. (5) REMOVABLE HINGED R.A./ACCESS PANEL RETURN RIGHT SIDE VIEW STANDARD STAMPED RETURN GRILLE & " FILTER Unit Model Dimensions - Inches (Millimeters) Quantity/Unit Unit Weight* A B C E F G Blower Motor CXB02 38 (95) 7-/8 (435) 0-7/ (25) 34 (84) 5-3/4 (4) (279) 98 CXB03 42 (07) 2 (54) 0-/4 (20) 38 (95) 5-3/4 (4) (279) 8 CXB04 48 (29) 25-7/8 (57) -/ (28) 44 (8) 5-3/4 (4) (279) 2 2 CXB0 53 (34) 34-5/8 (879) 9-3/ (233) 49 (245) -3/4 (7) 2 (305) 2 8 CXB08 0 (524) 39 (99) 0-/2 (27) 5 (422) -3/4 (7) 2 (305) 2 7 CXB0 74 (880) 52-/8 (324) 0-5/ (22) 70 (778) -3/4 (7) 2 (305) CXB2 82 (2083) 0-7/8 (54) 0-9/ (28) 78 (98) -3/4 (7) 2 (305) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Internal factory valve packages and drains may not align w/cabinet knockouts. 3. All dimensions are +/- /4" (). 4. Product specifications are subject to change without notice. 5. Drip lip required for units with valves. Drawing is not to scale and is provided for. Control box size and position may vary (consult factory). reference only. Dimensions may vary with 7. Threaded fittings must be field tightened and leak tested. options ordered. Consult IEC web site for up to date drawings. 24

25 PHYSICAL DATA, Cont d. CXB - Horizontal Cabinet with optional Electric Heat 3-/2 (89) CONTROL BOX UNIT LABEL AND WIRING DIAGRAM (SEE NOTE ) STAMPED RETURN GRILLE & " FILTER "L" SHAPED DRIP LIP, SHIPPED LOOSE (NOTE 5) 8 (457) ELECTRIC STRIP HEATER ELEMENT 7/8 (22) O.D. CONDENSATE DRAIN CONNECTION 7/8 (22) KNOCKOUT (TYP. OF 2) KNOCKOUT (TYP. OF 5) 2 (5) 2 (5) E A TOP VIEW CHILLED/HOT WATER SUPPLY & RETURN CONNECTIONS (SEE SUPPLEMENTAL DRAWING FOR COIL STUBOUT LOCATIONS) 2 (5) PARTIAL REAR VIEW (TYPICAL BOTH SIDES) C B C 23-/2 (597) VENT G F SUPPLY RETURN 5-3/4 LOCATION (4) STANDARD STAMPED SUPPLY GRILLE FRONT VIEW RESILIENT MOUNTING GROMMETS WITH 3/8 (0) DIA. HOLE (TYP. OF 4) APPROX. 2 REF. (5) REMOVABLE HINGED R.A./ACCESS PANEL RETURN RIGHT SIDE VIEW STANDARD STAMPED RETURN GRILLE & " FILTER Unit Model Dimensions - Inches (Millimeters) Quantity/Unit Unit Weight* A B C E F G Blower Motor CXB02 38 (95) 7-/8 (435) 0-7/ (25) 34 (84) 5-3/4 (4) (279) 00 CXB03 42 (07) 2 (54) 0-/4 (20) 38 (95) 5-3/4 (4) (279) 20 CXB04 48 (29) 25-7/8 (57) -/ (28) 44 (8) 5-3/4 (4) (279) 2 28 CXB0 53 (34) 34-5/8 (879) 9-3/ (233) 49 (245) -3/4 (7) 2 (305) 2 70 CXB08 0 (524) 39 (99) 0-/2 (27) 5 (422) -3/4 (7) 2 (305) 2 78 CXB0 74 (880) 52-/8 (324) 0-5/ (22) 70 (778) -3/4 (7) 2 (305) CXB2 82 (2083) 0-7/8 (54) 0-9/ (28) 78 (98) -3/4 (7) 2 (305) NOTES: * Unit weights (shown in pounds) are based on dry coils, minimum rows and exclude packaging, valves or other components.. RH shown, LH opposite. 2. Internal factory valve packages and drains may not align w/cabinet knockouts. 3. All dimensions are +/- /4" (). 4. Product specifications are subject to change without notice. Drawing is not to scale and is provided for 5. Drip lip required for units with valves. reference only. Dimensions may vary with. Control box size and position may vary (consult factory). options ordered. Consult IEC web site for 7. Threaded fittings must be field tightened and leak tested. up to date drawings. 25

26 STANDARD FEATURES & OPTIONS Features And Options Standard Factory Installed Option Field Installed Option Factory Special Quote Air Flow Arrangement Front Supply/Rear Return (CHY) X Front Supply/Rear or Bottom Return (CPY, CBY, CXB) X (Bottom) X (Rear) Coils 2 Rows 2-Pipe (CHY, CPY, CBY, CXB) X 3 Rows 2-Pipe (CHY, CPY, CBY, CXB) X 4 Rows 2-Pipe (CHY, CPY, CBY, CXB) X 3/, 3/2, 4/ Rows 4-Pipe (CHY, CPY, CBY, CXB) X Manual Air Vent X Automatic Air Vent X DX Coils X Steam Coils X X Connection Right or Left (Same End) X Right or Left (Opposite End) X Drain Pan Galvanized Internally Coated with 2-part closed Cell Foam X Stainless Steel Externally Coated X Drip Lip (recommended with motorized valves) X Extended Drain Pans (CHY, CPY) X Secondary Drain Connection X v Fin Material Aluminum with Galvanized End Sheets X Copper with Stainless End Sheets & Bottom Coil Baffle X X Nichrome Wire Strip Electric Heater (Total and Auxiliary) X Filters " Throwaway non-woven synthetic filter X " Permanent X " Pleated MERV 8 X Insulation /2" Standard Fiberglass X /2" Premium IAQ Fiberglass X X /2" Foil Face X /4" Closed Cell X Motor Type PSC Motors with Quick Connect Plug X Motor Voltage 20//0 3-Speed X 208/230/277//0 3-Speed (Optional Voltage) X Supply/Return Air Grilles Louvered Stamped Supply Grille (CXB) X Double Deflection, Aluminum Finish Supply Grille X (CXB X (CHY, CPY, X (CHY, CPY, CBY) CBY) Double Deflection, Integral Supply Grille - painted X (CXB) Stamped Return Grille (CBY, CXB) X Hinged Bar-Type, Aluminum-finish Return Grille with Throwaway Filter - F.O. X (CHY, CPY, CBY) X (CHY, CPY, CBY) Controls Service Switch with Lockout Tabs X Single Point Power Connection X Incoming Power Fusing X 24 V Controls X Condensate Overflow Switch X 3-Speed Switch X X Thermostats X Custom Control (DDC) X X 2

27 STANDARD FEATURES & OPTIONS, Cont d. As detailed in the table on page 27, we offer a control for most of the customer needs. Additional controls and devices are available to meet even the most demanding operating logic. Three-speed Fan Control All of our basic control schemes utilize a 2- or 3-speed switch to modulate the cooling output, to maximize the percentage of latent heat removal, and to further minimize the sound level when maximum cooling or heating performance is not required. Low Voltage Control (24 V) A low voltage control is available with all of our control schemes. Condensate High Level Switch This switch shuts down the unit when the water level in the drain pan reaches an unsafe level. Building code changes in much of the country now require this type of device. Service Switches We offer concealed service switches for use by maintenance and service personnel to shut off the power while working on the unit. Fusing We offer incoming power fusing for all units as well as blower motor and control sub-fusing for units that use electric heat. The blower motor and control sub-fusing (single power source wiring) is required when single source power with electric heat is specified. Control Packages Vertical Wall Series V Programmable and Non-Programmable Digital Series 27

28 STANDARD FEATURES & OPTIONS, Cont d. Control Package Applications Unit Type Control Option System Type Changeover Type Vertical and Horizontal Wall Series V Programmable and Non-Programmable Digital Series Manual Fan Manual None Heat Only None Cool Only None Manual Heat/Cool Automatic 2-Pipe Valve Heat/Cool with Auxiliary Manual Cycle* Electric Heat Automatic NOTE: 4-Pipe Cool with Total Electric Heat Heat/Cool. Fan switch only; no thermostat. Manual Automatic Manual Automatic Thermostat Features Control Type All listed controls include fan switching. Vertical and Horizontal Wall Series V Digital Series 24 V, 5 V, 208 V, 240 V, 277 V 24 V only Remote Wall Mounted Manual Fan Switch Operation Auto Fan Speed Control N/A Continuous 3-Speed Fan Cycling Fan N/A O.A. Damper Signal Remote Temperature Sensor Opt Opt Adjustable Operating Range Kit Touch Pad/Digital Display N/A Local Temperature Set-Back N/A Water Temperature Purge Cycle N/A Pipe Sensor N/A NOTES:. Control packages with valve cycle control are continuous fan operation only. 2. All wall-mount control packages are shipped loose for field installation. (Boxes, tile rings, plaster rings, etc. are not provided.) 3. Aquastats are included in control packages, as required. Control Options 24 V control packages Unit-mounted fan switches (Special Quote) Single power source wiring (motor/control fusing) Incoming power fusing Service switches Minimum room temperature thermostats (Special Quote) Low voltage remote shutdown relays (Special Quote) Fan and valve cycle applications (Special Quote) Thermostats available with large letter print for handicap applications (Special Quote) DX coil applications 28

29 STANDARD FEATURES & OPTIONS, Cont d. Supply Air Grilles Unit Size Nominal CFM Recommended Grille Size - Inches (Millimeters) " x " (40 x 52) " x " (508 x 52) " x " (0 x 52) " x " (72 x 52) " x " (95 x 52) " x " (320 x 52) " x " (524 x 52) NOTES:. Refer to Physical Data, pages 3 through 2 for actual unit supply air opening dimensions. 2. Field-furnished duct transitions may be required. Return Air Filter Grilles Unit Size Nominal CFM Recommended Grille Size - Inches (Millimeters) " x 0" (0 x 254) " x 0" (7 x 254) " x 0" (83 x 254) " x 0" (07 x 254) " x 0" (07 x 254) " x 0" (372 x 254) " x 0" (2 x 254) NOTES:. Refer to Physical Data, pages 3 through 2 for actual unit return air opening dimensions. 2. Field-furnished duct transitions may be required. Optional Double Deflection, Aluminum-finish Supply Grille (Optional special ship separate for models CHY, CPY, and CBY. Consult factory for details.) Optional Hinged, Bar-type, Aluminum-finish Return Grille with Throwaway Filter (Optional special ship separate for models CHY, CPY, and CBY. Consult factory for details.) Optional Double-deflection, Integral Supply Grille Painted to Match Color of Unit 29

30 STANDARD FEATURES & OPTIONS, Cont d. Nominal Filter Sizes All cabinet model units (except CH) have non-woven synthetic throwaway filters furnished as standard equipment. Cleanable and pleated filters are optional. Unit Size CHY (Note ) 0" x 24" (254 x 0) 0" x 28" (254 x 7) 0" x 32" (254 x 83) 0" x 42" (254 x 07) 0" x 42" (254 x 07) 0" x 54" (254 x 372) 0" x 4" (254 x 2) CPY 0" x 8" (254 x 457) 0" x 22" (254 x 559) 0" x 28" (254 x 7) 0" x 33" (254 x 838) 0" x 40" (254 x 0) 0" x 54" (254 x 372) 0" x 2" (254 x 575) Nominal One-Inch Filter Size - Inches (Millimeters) CBY Bottom Return Stamped 0" x 28" (254 x 7) 0" x 28" (254 x 7) 0" x 33" (254 x 838) 0" x 45" (254 x 43) 0" x 45" (254 x 2) 0" x 2" (254 x 575) 0" x 2" (254 x 575) CBY Rear Return Stamped 7" x 2" (78 x 533) 7" x 2" (78 x 533) 7" x 27" (78 x 533) 7" x 38" (78 x 95) 7" x 38" (78 x 95) 7" x 52" (78 x 32) 7" x 52" (78 x 32) CXB Bottom Return Stamped 0" x 23-/2" (254 x 597) 0" x 28" (254 x 7) 0" x 32-/2" (254 x 82) 0" x 37" (254 x 940) 0" x 4" (254 x 04) 0" x 54-/2" (254 x 384) 0" x 3" (254 x 00) CXB Rear Return Stamped 8" x 23-/2" (203 x 597) 8" x 28" (203 x 7) 8" x 32-/2" (203 x 82) 8" x 37" (203 x 940) 8" x 4" (203 x 04) 8" x 54-/2" (203 x 384) 8" x 3" (203 x 00) NOTES:. Filter sizes for the CH models are recommended filter sizes only. No filter is factory provided with these models. 2. Sizes shown are nominal ordering sizes. CXB Rear Return Ducted 8" x 23-/2" (203 x 597) 8" x 28" (203 x 7) 8" x 32-/2" (203 x 82) 8" x 37" (203 x 940) 8" x 4" (203 x 04) 8" x 54-/2" (203 x 384) 8" x 3" (203 x 00) 30

31 PIPING PACKAGES (TYPICAL) Two-way Motorized Control Valve In a two-way motorized control valve package, the motor drives the valve open, and a spring returns the valve to a normally closed position. No water flows with the unit off. The standard supply connection from the coil will accept a swaged copper fitting for field brazing. As an option, this connection may be factory furnished with a union. When a swage is necessary, it becomes part of the valve package. The isolation, or ball, valve in the return piping is shipped loose for field installation. Air Vent Three-way Motorized Control Valve In a three-way motorized control valve package, a diverting valve controls water flow to the coil. When the unit is off, water bypasses the coil and flows directly to the system return. A balancing valve may be specified in the bypass line to permit equal flow balancing. Air Vent Coil R Swage 3-way Valve Ball Valve Optional Balance Valve R Coil R S Swage 2-way Valve Ball Valve (Ships Separate) Ball Valve Two-way Motorized Control Valve with Changeover In a two-way motorized changeover control valve package, the motor drives the valve open, and a spring returns the valve to a normally closed position. No water flows through the coil with the unit off. The aquastat bypass line allows a small amount of water to flow from the supply to the return piping when the control valve is closed. The strapon aquastat senses whether the flowing water is cold or hot and switches a contact closed to provide automatic summer/winter changeover (ACO) for the system. R S S Swage A Aquastat Ball Valve NOTES:. Please note that project specifications for system pressure, pressure drop limitations and flow rate should be checked prior to selecting specific components or the valve package size. 2. The supply and return piping connections of the factory-provided valve package are either swaged for field brazing (standard) or union fitted (optional) for connection to the coil. 3. Consult IEC s Valve Packages and Piping Components manual or your local representative for detailed piping and valve application information. Factoryprovided valve packages are assembled, brazed, wired electrically and dry-fit to the coil connections before shipping. Field brazing to the coil completes the installation. Some applications dictate shipping isolation valves loose. S Air Vent R Swage Ball Valve R Coil S Swage 2-way Valve A Aquastat Aquastat Bleed Bypass Line Ball Valve S 3

32 IEC Catalog Part #: I CA-020 Revision 8 (8/20) International Environmental Corporation (IEC) P.O. Box 2598 Oklahoma City, OK p: f:

Horizontal Series Fan Coil Technical Catalog

Horizontal Series Fan Coil Technical Catalog Horizontal Series Fan Coil Technical Catalog HCY Horizontal Hideaway 200 CFM to 200 CFM The Horizontal Hideaway (HCY) fan coil unit is designed specifically to meet the many varied requirements for a ceiling

More information

Hi-Performance Series Fan Coil Technical Catalog

Hi-Performance Series Fan Coil Technical Catalog Hi-Performance Series Fan Coil Technical Catalog HYB Horizontal Hideaway Furred-in with galvanized finish for ducted/high static applications in drop-ceilings or over-closets. (600-2000 CFM) HGC Horizontal

More information

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated

More information

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model

More information

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

Product Data. 42D Ducted Fan Coil Air Conditioners cfm Product Data 42D Ducted Fan Coil Air Conditioners 600-2000 cfm Carrier s 42D series ducted fan coil units offer design and equipment location flexibility Choice of 5 models, each available in 8 sizes For

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE Low Power Consumption, Accessible, & FW and FL Fan-Coil Design Features Owners Owners can choose between a standard height (FW)

More information

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE

More information

FCVC Series VERTICAL FAN COILS

FCVC Series VERTICAL FAN COILS VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,

More information

FN Fan-Coil Units High-Performance, Horizontal

FN Fan-Coil Units High-Performance, Horizontal FN Fan-Coil Units High-Performance, Horizontal Model FNX Exposed-Cabinet Dimensional Data Notes: 1. All dimensions are in inches [mm] and are +/- 1/8" [3 mm]. Metric values are soft conversions. 2. See

More information

Submittal. Front View Side View

Submittal. Front View Side View RBHO Horizontal Low Profile Concealed Free Return Submittal FCU-RBHO-1.0 07-25-18 Top View (Drain Pan Omitted) Bottom View Front View Side View Left hand unit shown. All dimensions are inches [millimeters].

More information

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L TVBA TVBC TVBF Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVB: LOW POWER CONSUMPTION, ACCESSIBLE

More information

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778] FCU-THBP-1.0 08-22-18 THBP Horizontal Low Profile Plenum Return Top View (Drain Pan Omitted) Bottom View Front View Left hand unit shown. All dimensions are inches [millimeters]. Side View Unit Size A

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018 Replacement s List 700024100 Revision C 03/2018 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016 Replacement s List 70002400 Revision B 03/206 Daikin McQuay Large Capacity Fan Coil Direct Drive HCDB, HHDB 06-20 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application 42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code

More information

Horizontal Fan Coils 200-1,200 CFM

Horizontal Fan Coils 200-1,200 CFM Horizontal Fan Coils 200-1,200 CFM Table of Contents Williams Fan Coils & Air Handlers..................................................... 1 Horizontal Models......................................................................

More information

GENERAL ELECTRIC FAN COIL UNITS

GENERAL ELECTRIC FAN COIL UNITS GENERAL ELECTRIC FAN COIL S Chilled Water System CFM thru CFM GE_AWHE_series.indd 3/6/ 3:3 PM GE_AWHE_series.indd 3/6/ 3:3 PM CONTENTS Outstanding features 4 Model decoding 5 A pplications 5 Physical data

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

RAH Engineering Guide

RAH Engineering Guide FAN COIL UNITS FREE RETURN RAH Engineering Guide SO TOUGH, WE GUARANTEE IT. RAHC RAHO RAHR www.superiorrex.com Table of Contents Features and Benefits... 3 Construction Features... 4 Standard and Optional

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018 Replacement s List No. 700024000 Revision E 03/2018 Daikin McQuay Large Capacity Fan Coil Belt Drive HCBB, HHBB 08-30 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit

More information

Submittal 6 [152] 6 [152] 8 [203]

Submittal 6 [152] 6 [152] 8 [203] TVSR Vertical High Rise Recessed Stand lone Fan Coil Unit (Do not Include Risers See note ) Submittal FCU-TVS-R-1.0 03-01- 2 - Pipe Top Views 4 - Pipe Unit Size 03 & 04 0 & 0 10 & 20 [50] 24 [10] 1 ½ [419]

More information

Vertical Hi-Rise Fan Coil Unit (Model FS)

Vertical Hi-Rise Fan Coil Unit (Model FS) Technical Bulletin Issue Date March 1, 2005 Vertical Hi-Rise Fan Coil Unit (Model FS) Model FS Vertical Hi-Rise fan coil units are designed to maximize flexibility of selection and installation. The units

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.

More information

RBV Engineering Guide

RBV Engineering Guide VERTICAL FLOOR-MOUNTED FAN COIL UNITS RBV Engineering Guide SO TOUGH, WE GUARANTEE IT. RBVS RBVC RBVR www.superiorrex.com Table of Contents Features and Benefits... 3 Construction Features... 4 Standard

More information

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View. Horizontal Low Profile oncealed with Plenum FU-RBHR-1.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041]

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed

More information

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM 42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette

More information

Vertical Floor Fan Coil Unit (Model FW)

Vertical Floor Fan Coil Unit (Model FW) Technical Bulletin Issue Date March 24, 2005 Vertical Floor Fan Coil Unit (Model FW) Figure 1: Model FWX Vertical Exposed Model FW Vertical Floor fan coil units are designed to maximize flexibility of

More information

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS TABLE OF CONTENTS H & V Features and Benefits...4 Coil and Filter Data, Static Pressure Data...7 Electric Resistance Heat Section...8 Coil Information

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

Product Data. Features/Benefits. 42C,D,S,V Series Fan Coil Air Conditioners 50/60 Hz. 150 to 2000 cfm

Product Data. Features/Benefits. 42C,D,S,V Series Fan Coil Air Conditioners 50/60 Hz. 150 to 2000 cfm Product Data 2C,D,S,V Series Fan Coil Air Conditioners 50/60 Hz 150 to 2000 cfm 2SH STACK 2CA HORIZONTAL 2DA DUCTED 2VB VERTICAL Carrier s 2C,D,S,V Series fan-coil units combine design flexibility with

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed

More information

High Performance Fan Coils FCHG Genesis Series Horizontal

High Performance Fan Coils FCHG Genesis Series Horizontal Dimensional Data 5 7 /8 (150) D 14 (356) 2 (51) Diverter - Slides Into Discharge Ductwork Optional: Second Drain Pan Connection E Coil Section X Dimensional Data - IP (in.) / SI [mm] Unit Fan Outlet Duct

More information

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016 Replacement Parts List 057117500 Revision C 08/2016 McQuay Seasonmaker Horizontal Fan Coil TSC 021-121 Vintage G Last Manufactured: 1997 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL COIL UNITS MAGIC AIRE FFW/FSW/FHW/FHW SERIES COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4

More information

Vertical Stack Fan Coils 300-1,200 CFM

Vertical Stack Fan Coils 300-1,200 CFM Vertical Stack Fan Coils 300-1,200 CFM Table of Contents Williams Fan Coils & Air Handlers... 1 Vertical Stack Models... 2 Features & Benefits... 4 Equipment Options... 5 ARI Cooling Capacity... 6 Heating

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

FDCLP2 Constant Volume Series Flow, Low Profile

FDCLP2 Constant Volume Series Flow, Low Profile The Price low profile series fan powered terminal unit is an ideal product for use in typical series fan powered applications with limited ceiling space. The is designed for constant air volume applications,

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019 Replacement Parts List No. 700053700 Revision A 03/2019 Daikin PreciseLine Horizontal Large Capacity Blower Coil BCHD 030-050 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series. Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT MADE IN USA SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425) ENVIRONMENTALLY SOUND REFRIGERANT FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2.5, and 3 Tons Upflow application only For use with R 410A refrigerant or R 22 with accessory TXV

More information

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES FAN TERMINAL UNIT SPECIFIABLE FEATURES Galvanized steel casing, mechanically sealed for low leakage construction NEMA TYPE 1 rated hinged control enclosure with standoff to prevent penetration of casing

More information

August PRODUCT DESIGN GUIDE Inteli-line Vertical Stack Fan Coil with Slide-Out Chassis

August PRODUCT DESIGN GUIDE Inteli-line Vertical Stack Fan Coil with Slide-Out Chassis August 2018 PRODUCT DESIGN GUIDE with Slide-Out Chassis Table of Contents with Slide-Out Chassis Cabinet Nomenclature 1 Chassis Nomenclature 2 AHRI Performance Rating 3 Features & Benefits 4 Physical Data

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED Direct Drive, Draw-through Design Model Series 3FH Filter 1" (2) throwaway (standard) 2" (1) MERV 8 or MERV 13 pleated (optional) Multiple coil options: 3, 4,, 6 row cooling or heating coils 1 or 2 row

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001 42CHS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM QMS 001 World's No.1 Air Conditioning Expert www.carrier.co.th 42CHS-W Series Furred-in ceiling model 400-2000

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool

More information

Submittal. Holder Construction Company. Reviewed. Reviewed as Noted. Rejected. 1. Updates per Bulletin #4

Submittal. Holder Construction Company. Reviewed. Reviewed as Noted. Rejected. 1. Updates per Bulletin #4 Holder Construction Company 230 Peachtree Street NW, Suite 1250 Atlanta, GA 30303 Submittal Project Telephone #404.688.6233 Project Name: Submittal Number: Submittal Description: Submittal Review Date:

More information

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) TECHNICAL SPECIFICATIONS HMG*T Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG*T series of air handlers, when combined with our heat pump or air conditioner, offer

More information

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor

SUBMITTAL DATA. for. MWSU-Popplewell Hall 1st Floor SUBMITTAL DATA for Prepared by Kevyn Gordon 4/27/2017 Job Name: 1 of 35 www.daikinapplied.com Table of Contents Technical Data Sheet for AHU-1st Floor... 3 Fan Curve for AHU-1st Floor... 7 Drawing for

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986 Replacement Parts List No. 47650300 Rev. A 09/205 McQuay Seasonmaker Large Capacity Fan Coil Direct Drive SCD, SHD 06-20 Vintage A Last Manufactured: 986 To find your Daikin Applied parts distributor,

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features and Field Installed Accessories Standard Features White Pre-Painted Sheet

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

BHH Product Specifications

BHH Product Specifications BHH Product Specifications HORIZONTAL BELT DRIVE DIRECT EXPANSION BLOWER COIL UNITS ALL S 3, 4, and 5 Ton 208/230 3 60 and 460 3 60 supply voltage Units are ETL listed to U.S. and Canadian safety standards

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information