Conserving Energy Since 1946 VFM Technical Data. Vortex Flowmeter
|
|
- Anissa Andrews
- 6 years ago
- Views:
Transcription
1 Conserving Energy Since 1946 VFM 7000 Technical Data Vortex Flowmeter
2 Measuring Principle The Vortex flowmeter is used for measuring the flow velocity of fluids in pipelines. The measuring principle is based on the development of a Karman Vortex shedding street in the wake of body built into the pipeline. The periodic shedding occurs first from one side and then from the other side of a bluff body (Vortexshedding body) installed perpendicular to the axis. Vortex shedding generates a so-called "Karman Vortex Street" with alternating pressure conditions whose frequency f is proportional to the flow velocity v. The non dimensional Strouhal number S (primary head constant) describes the relationship between the vortex shedding frequency f(in Hz), width b of the body and the mean flow velocity v (in m/s). f = S. v / b The flexural vibration of the vortex-shedding body is picked up in the primary head via sensors and analysed in the signal converter. Karman Vortex Street v b b The ultimate application specific flowmeter Forbes Marshall Vortex flowmeters operate on the Karman Vortex shedding street principle to measure the volumetric flowrate of gases, steam and liquids. The VFM 7000 unit consists of a VFS 7000(I) primary head and a VFC 090 flow converter with application specific software for various applications. Features PTB Certificate No. Ex-01 E.2067 conforms to Ex de[ib] IIC T6...T2 and EEx d[ib] IIC T6...T2 No mechanically moving parts High measuring accuracy Wafer/sandwich type DN 25 to 150 (1" to 6") Meter sizes flanged DN 10S to 200 (/8"S to 8") Small sizes DN 10S to 20 (/8"S to /4") with integral U/S and D/S pipes and flanges Compact unit, maintenance-free Microprocessor based digital signal converter using SMD technology Powerful LCD display with excellent readability Integrated volume/mass totalizers Full programmable parameters like flow range, engg. units, medium constants, current/frequency outputs Flameproof CSA Number for Explosion Proof Class 1 Zone 1 II C Class 1 Division 2 Group A, B, C&D F M approval - pending Conforms to CE Mark as per EMC Directive, LVD and PED Built-in self diagnostics Wetted parts of SS 16L/04 and Titanium High rangeability/turn-down ratio Simple programming and user-friendly interface Current and frequency outputs as standard features. RS22/485 digital communication can be optionally provided in lieu of frequency output External programming with magnetic sensors and bar magnet without having to open the cover of the electronic housing Online temperature/pressure compensation and mass flow computation with built-in temperature and pressure sensors Special application specific software for FAD, Natural Gas, Steam Metering, Condensate Metering, Gas flow Metering, Heat Metering and Net Heat Metering (ref. pg.14) Notch filter algorithm for estimating accurate frequency or vortex shedding 1
3 Application For flow velocities up to ft/s for liquids and 246 ft/s for gases. Specially developed for Steam Flow Measurement/Gas Flow Metering/Natural Gas Flow Metering applications. Measurement of low conductive liquids. Automatic Density Correction can give flow rates in lbs/hr for steam and scfm of gases with standard online temperature compensation and optional pressure compensation. Windows based sizing software can be provided on request for speedy choice to give you: Correct size Minimum and maximum flow rates The turndown The pressure loss Overall pressure loss in pipe by calculating pressure drop in expander/reducer and straight sections Options VFM 7000 K - Compact system, signal converter is mounted on the primary head. F - Separated system, signal converter is mounted away from the primary head, primary head with connection box max. distance 2.8 ft (10 m). 2
4 Technical Data Flowmeter Primary Head/Sensor VFS 7000(I) Versions and meter sizes Pressure ratings see Table "Dimensions" on page 10 (Note the operating limits to DIN 2401 and ANSI B 16.5) Wafer/sandwich design to... DIN DN 25 to 150 ANSI 1" to 6" Flange connections to... DIN 2501 DN 10S to 200 ANSI B 16.5 /8"S to 8" Groove joint to... (optional) DIN 2512 DN 25 to 150 ANSI Other process connections 1" to 6" JIS and other standards on request Product and ambient temperature Hazardous duty versions Accuracies Operating volumetric flow (Reynolds Number>20000) Measuring error Standardized/Normalized volumetric & mass flow (Reynolds Number>20000) Measuring error Repeatability Product Temperature error See Diagram III on page 5 CMRI, PTB, CSA approvals (see page 1) FM approval is pending ±1% of measured value for DN 25 to 200 and ANSI 1" to 8" ± 2% of measured value for DN 10S to 20, ANSI /8"S to /4" ± 1.5% of measured value for DN 25 to 200 and ANSI 1" to 8" ± 2.5% of measured value for DN 10S to 20 and ANSI /8"S to /4" ± 0.5% of measured value Compensated by software only Materials SR.NO DESCRIPTION MATERIAL REMARKS 1 Housing Stainless Steel, A51 CFM (16L) Up to size DN 100/4" Stainless Steel, A51 CF8M (04) From DN 150/6" to DN 200/8" 2 Vortex shedding body Unalloyed Titanium (No..705) as standard Seals for Damper Pin a. b. c. Up to 56º F ( 180ºC) Up to 428 ºF ( 220ºC) Up to 464º F ( 240ºC) Viton O ring Kalrez 4079 O ring Parofluor O ring Non steam applications Non steam applications Steam applications 4 Bluff body metal seal C ring Inconel Ni plated Once used metal C ring should not be used again. Tightening torques for new seals are M6= 1.5 kg-m M8= 2 kg-m M10= 5.5 kg-m 5 Upstream & Downstream Straight Carbon steel (sch 40) Black powder coated pipes for wafer/sandwich units only Stainless Steel SS04/SS16 Shot blast finished (optional but recommended) 6 Locating pipe flanges Carbon steel for wafer/sandwich units (optional) Stainless Steel SS04/SS16 7 Gaskets (supplied as a Gasket, style AF-19, Non Asbestos standard accessory for both Gasket, style AF-160, Non Asbestos Any one as per application wafer and flanged units) Gasket, Teflon (PTFE)
5 Pressure loss p Diagram I Diagram II Pressure loss p for air 1.01 bar (14.69 psi) and 2ºF (0ºC) Pressure loss p for water 68ºF (20ºC) and ρn = 62.1 lbs/ft and ρn = lbs/ft (1.29 kg/m ) (998.2 kg/m ) p (psig) p(mbar) p (psig) p(mbar) A B C D E F G H I J K m/h US GPM A B C D E F G H I J K m/h US GPM
6 Diagram III T u ºC (ºF) 60 (140) 40 (104) 0 (86) 20 (68) T T u m Ambient temperature Product temperature Standard version High-temperature version Hazardous duty version 0 (2) (-.99) (-1) T m ºC (ºF) (-.99) (2) (122) (212) (284) (56) (428) (464) Diagram IV Min. flow velocity at various densities for gases and saturated steam Velocity Vmin in m/s 1 Velocity Vmin in m/s 10 1 A B C D Density kg/m Density kg/m DN 25(1 ) to DN 200(8 ) DN 10S(/8 S) to DN 20(/4 ) Velocity (ft/s) 10 1 Velocity(ft/s) 10 1 A B C D Density (lbs/ft ) DN 25(1 ) to DN 200(8 ) Density (lbs/ft ) DN 10S(/8 S) to DN 20(/4 ) Curve Meter size A DN 10S/ /8"S B DN 10/ /8" C DN 15/ 1/2" D DN 20/ /4" 5
7 Singal Converter VFC 090 Full scale range Power Supply Power Consumption Ambient temperature Tu Local display Display functions Programmable in liters, m, US/UK gallons, kg, tons, lbs, cub.ft.or standard flowrate per second, minute or hour 240/220/200/120/110/100 V AC +10% } -15% 20VAC +6% 48 to 6 Hz -10% AC: 15 VA See Diagram III, page 5 -field back-lit LCD Actual flowrate and sum totalizer (8-digit), each programmable for continuous or sequential display of measured parameters and error messages Display units Actual flowrate Units list as per full scale range or percentage of full scale independently programmed Totalizer liters, m, US/UK gallon, kg, tons, lbs, cub. ft. Language of plain texts German, English, French Display st 1 field (top) 8-digit, 7-segment numeric display, symbols for key acknowledgement nd 2 field (middle) 10-character, 14-segment text display rd field (bottom) 6 markers to identify actual display Mass flow measurement Manual through keypad or online with optional integrated temperature and pressure sensors Housing, signal converter With separate connection compartment Material Die-cast aluminium Protection category IP 65 & IP 67 (better than NEMA 4& 4X) (EN 60529/IEC 529) Current output Operating data programmable, galvanically isolated (not from frequency output) Current 0/4 to 20 ma corresponding to flow values independently programmable with min. span equal to 20% of full scale. Accuracy + 0.1% of FS Temp. coefficient 100 ppm of full scale range per 1 o C Max. load at I100% (20 ma) 700Ω Error annunciation l error=2/22 ma programmable Frequency output Operating data programmable, galvanically isolated (not from current output) Pulse rate for q=100% 10 to pulse per hour to pluses per minute to pluses per second (=Hz) optionally in pulses per liter, m, US/UK gallon, kg, ton, lb, cub. ft. Active output short-circuit-proof suitable for electromechanical (EMC) OR electronic (EC) totalizer Amplitude max. 24 V Load rating See Table "Pulse Width' on page 7 Passive output Open collector for connection of active electronic totalizers (EC) or switchgear Input voltage (external supply) 5 to 24 V Load current Max. 100 ma Ri 100 ohms Accuracy Frequency output mode + 0.% of value Pluse output mode: 0% (no additional error) Communication options RS485 board can be fitted on request in lieu of frequency output for communication of all parameters such as flow, totalized flow, pressure and temperature 6
8 Pulse width Frequency f = F (atq = 100%) Load rating of active output 100% Load current Load 500 ms Hz < f 1 Hz 150 ma 160 Ohm 200 ms Hz < f 2 Hz 150 ma 160 Ohm 100 ms Hz < f Hz 150 ma 160 Ohm 100 ms Hz < f 5 Hz 60 ma 400 Ohm 50 ms Hz < f 5 Hz 150 ma 160 Ohm 50 ms 5 Hz < f 10 Hz 60 ma 400 Ohm 0 ms Hz < f 6 Hz 150 ma 160 Ohm 0 ms 6 Hz < f 10 Hz 80 ma 00 Ohm Pulse duty factor 1:1 10 Hz < f 1000 Hz 25 ma 1000 Ohm 160 µ s Hz < f 2547 Hz 25 ma 1000 Ohm 50 µ s 2547 Hz < f Hz 25 ma 1000 Ohm Dimension Details Wafer style version DN 25 to DN 150 (1" to 6") Wafer style version DN 25 to DN 150 (1" to 6") with locating pipes * Optional * Optional 150 lbs and 00 lbs pipe and meter mating flanges with U/S & D/S straight pipes. 1" and 1.5" meter mating flanges with 00 lbs only but pipe mating flanges can be 150 lbs/00 lbs. *Can be supplied on request Flange version DN 25 to DN 50 (1" & 2") 7
9 Dimension Details Flange version DN 80 to DN 150 (" to 6") 156(6.14") # PG 16 ø122(4.8") 204(8.0") * ø122(4.8") For EX Version * 240 mm (9.45") # 186 mm (7.2") b di a c Flange version DN 200 (8") 156(6.14")# 204(8.0") * PG 16 ø122(4.8") For EX Version * 240 mm (9.45") # 186 mm (7.2") b a di c DN 10S to DN 20 (/8"S to /4") with U/S & D/S piping (standard) 204(8.0") * 156(6.14") # PG 16 For EX Version * 240 mm (9.45") # 186 mm (7.2") b ø122(4.8") c l a 8
10 IFC 020 IFC 020 VFM 7000 Technical Data The purchaser is solely responsible for the suitability in accordance with the technical regulation and applicability of our instruments. Range limits for gases based on air at T = 2ºF at psia and density = lbs/ft (1.29 kg/m ) ANSI meters DIN meters Meter Size Inside Vmin Qmin Vmax Qmax Meter Size Inside Vmin Qmin Vmax Qmax ANSI Diameter(di) DIN Diameter(di) Inches Inches ft/s cfm ft/s cfm mm mm m/s m /hr m/s m /hr /8 S S / / / / Range limits for liquids based on water at 68ºF (20º C) ANSI meters Meter Size Inside Vmin Qmin Vmax Qmax ANSI Diameter(di) Inches Inches ft/s US GPM ft/s cfm /8 S / / / / DIN meters Meter Size Inside Vmin Qmin Vmax Qmax DIN Diameter(di) mm mm m/s US GPM m/s US GPM 10 S Flowrate Qm in lbs/hr for different pressure P and density ρ (ANSI meters) DN Inside P = 15 PSIG P = 50 PSIG P = 75 PSIG P = 100 PSIG P = 150 PSIG P = 200 PSIG P = 250 PSIG P = 00 PSIG ANSI Dia(di) ρ=0.072 lbs/ft ρ= lbs/ft ρ=0.206 lbs/ft ρ= lbs/ft ρ=0.627 lbs/ft ρ= lbs/ft ρ=0.576 lbs/ft ρ=0.679 lbs/ft inch inch min max min max min max min max min max min max min max min max /8"S /8" /2" /4" " /2" " " " " " Range limits for saturated steam Flowrate Qm in lbs/hr for different pressure P and density ρ (DIN meters) DN Inside P = 15 PSIG P = 50 PSIG P = 75 PSIG P = 100 PSIG P = 150 PSIG P = 200 PSIG P = 250 PSIG P = 00 PSIG DIN Dia(di) ρ=0.072 lbs/ft ρ= lbs/ft ρ=0.206 lbs/ft ρ= lbs/ft ρ=0.627 lbs/ft ρ= lbs/ft ρ=0.576 lbs/ft ρ=0.679 lbs/ft mm mm min max min max min max min max min max min max min max min max 10S
11 Dimensions and Weights Flange connections to DIN 2501 and ANSI B16.5 (Schedule 40) Wafer design to DIN and ANSI Groove joint to DIN 2512 and ANSI, dimensions on request Dimension 'a' without gaskets between flowmeter and pipe flanges. Gaskets not included with flowmeter. High temperature version with "raised" signal converter housing: dimensions b mm Note the operating limits to DIN 2401 and ANSI Flange connections to DIN 2501 and ANSI B16.5 Wafer version Meter size Pressure rating Dimensions in mm/inches Approximate weight DN:mm of flanges With pressure sensor Without With pressure ANSI:inches di a b c b c pressure sensor sensor mm inch mm inch mm inch mm inch mm inch mm inch kg lbs kg lbs DN 25 PN DN 25 PN " 00 LBS DN 40 PN DN 40 PN " 00 LBS DN 50 PN DN 50 PN DN 50 PN " 150 LBS " 00 LBS DN 80 PN DN 80 PN DN 80 PN " 150 LBS " 00 LBS DN 100 PN DN 100 PN DN 100 PN " 150 LBS " 00 LBS DN 150 PN DN 150 PN " 150 LBS " 00 LBS Dimension 'a' with Upstream (U/S) and Downstream (D/S) piping Meter Size With 20D U/S & With 0D U/S & With 40D U/S & With 50D U/S & ANSI/DIN 5D D/S 5D D/S 5D D/S 5D D/S Inch mm Inch mm Inch mm Inch mm 1"/DN "/DN "/DN "/DN "/DN "/DN
12 Dimensions and Weights (continued): Meter Sizes /8"S - /4" (DN 10S to DN 20) Wafer version Meter size Pressure rating Dimensions in mm/inches Approximate weight DN:mm of flanges With pr. sensor Without With pressure ANSI:inches di a b c c l pressure sensor sensor mm inch mm inch mm inch mm inch mm inch mm inch kg lbs kg lbs DN 10S DN10,PN DN10,PN DN15,PN DN15,PN DN20,PN DN25,PN DN25,PN /8"S 1/2"NB,ANSI /2"NB,ANSI /4"NB,ANSI /4"NB,ANSI "NB,ANSI "NB,ANSI DN 10 DN10,PN DN10,PN DN15,PN DN15,PN DN20,PN DN25,PN DN25,PN /8" 1/2"NB,ANSI /2"NB,ANSI /4"NB,ANSI /4"NB,ANSI "NB,ANSI "NB,ANSI DN 15 DN15,PN DN15,PN DN20,PN DN25,PN DN25,PN /2" 1/2"NB,ANSI /2"NB,ANSI /4"NB,ANSI /4"NB,ANSI "NB,ANSI "NB,ANSI DN 20 DN20,PN DN25,PN DN25,PN /4" /4"NB,ANSI /4"NB,ANSI "NB,ANSI "NB,ANSI
13 Dimensions and Weights (continued) Meter Sizes 1" - 8" (DN 25 to DN 200) Flanged version Meter size Pressure rating Dimensions in mm/inches Approximate weight DN:mm of flanges With pressure sensor Without With ANSI:inches di a b b c pressure sensor pressure sensor mm inch mm inch mm inch mm inch mm inch kg lbs kg lbs DN 25 PN DN 25 PN " 150 LBS " 00 LBS DN 40 PN DN 40 PN , " 150 LBS " 00 LBS DN 50 PN DN 50 PN DN 50 PN " 150 LBS " 00 LBS DN 80 PN DN 80 PN DN 80 PN " 150 LBS " 00 LBS DN 100 PN DN 100 PN DN 100 PN " 15 LBS " 00 LBS DN 150 PN DN 150 PN " 150 LBS " 00 LBS DN 200 PN DN 200 PN " 150 LBS " 00 LBS
14 Dimensions and Weights (continued) LOCATING FLANGE LOCATING FLANGE (DIN) FLANGES A B C D E F G H mm inch mm inch mm inch mm inch mm inch mm inch mm inch no. of holes DN25-PN DN25-PN DN40-PN DN40-PN DN50-PN DN50-PN DN50-PN DN80-PN DN80-PN DN80-PN DN100-PN DN100-PN DN100-PN DN150-PN DN150-PN LOCATING FLANGE (ANSI) FLANGES A B C D E F G H mm inch mm inch mm inch mm inch mm inch mm inch mm inch no. of holes 1"-00lbs "-00lbs "-150lbs "-00lbs "-150lbs "-00lbs "-150lbs "-00lbs "-150lbs "-00lbs
15 Application Specific Models Saturated Steam Meter: VFM 7000 SSM with built-in Pt 1000 temperature sensor and measuring mass flowrate of steam with online density compensation. Condensate Flowmeter: VFM 7000 CFM with built-in Pt 1000 temperature sensor and measuring mass flowrate of steam condensate with online density compensation. Gas Flowmeter: VFM 7000 GFM with built-in Pt 1000 temperature and pressure sensors, measuring the normalized volumetric or mass flowrate of gas with online pressure, temperature and compressibility factor (PTZ) correction. Compressibility factor correction uses the Redlich- Kwong equations. Free Air Delivery Flowmeter: VFM 7000 FAD for compressed air with built-in Pt 1000 temperature and pressure sensors, measuring the normalized volumetric or mass flowrate of compressed air with online pressure, temperature and compressibility factor (PTZ) correction and facility to program the compressor motor RPM and Relative Humidity (RH) for computing the FAD. Natural Gas Meter: VFM 7000 NGM with built-in Pt 1000 temperature and pressure sensors with added facility to program the gas composition and density computation according to American Gas Association standards, AGA 8. Detailed Characterization Method is used in the computation of compressibility factor and density correction. Heat Meter: VFM 7000 HM with built-in Pt 1000 temperature sensor to directly measure the heat content of steam, hot water or chilled water with density correction. It has two separate internal totalizers one for the mass flow and the other for the heat content. A look-up table for the specific Enthalpy vs. Temperature is programed in the unit for heat/energy calculation. Net Heat Meter: VFM 7000 NHM is an extension of VFM 7000 HM with a provision for a second temperature input, 4-20 ma, from an external temperature transmitter. It directly measures the net heat imparted to the process in the case of heating using steam or hot water, and heat extracted from the process in the case of cooling using chilled water. On request, it can also support the display of the billed amount in different currencies. VFM 7000 VFM 7000 VFM 7000 GFM VFM 7000 NHM 14
16 IFC 020 IFC 020 IFC 020 VFM 7000 Electrical connection Power supply, power consumption and load rating of outputs; see "Technical Data" (Page 6). Current and frequency outputs (I + F) must be galvanically isolated from all input and output circuits but not from each other. If I and F are used simultaneously, a grounded receiver instrument may only be connected to one of the two outputs. Power supply 0 Volt Volt Internal connection frequency output F Outputs N L FE AC Frequency output F active for EC or EMC Frequency output F active for EC Frequency output F passive V 24V + EMC EC EC + R 1K 1W EC V/max 100 ma EMC: electro mechanical counter EC: electronic counter R needed only for totalizers with input voltages Umax < 0 volt Umax 24 V 12 V 5 V R (Ohm).9 K Current Output I RS22 output (optional) RS485 output (optional) Ae.g. 0to20mA RXD TXD GND TX+ TX- GND to Remote System to Remote System 15
17 Application Information Installation guidelines Inside diameter of flowmeter must be same as that of pipeline. Install flowmeter in-line with pipe axis, gaskets must not intrude into pipeline. Shut off and control elements must be downstream of outlet runs. Install a flow straightener if disturbed flow conditions exist on the inlet side. Avoid pulsating flow and vibration. For flowmetering of steam and vapors, ensure a sufficient pressure is maintained downstream of the flowmeter to avoid cavitation and condensation. Use straight inlet and outlet runs Inlet run - downstream of reducer 20 x DN* - downstream of quarter bend 20 x DN - downstream of two quarter bends 0 x DN - downstream of three quarter bends 40 x DN - downstream of valves 50 x DN Outlet run 5xDN * DN = Meter size Position of Signal Converter Housing Please specify when ordering. Standard version supplied if the position is not specified. The arrows indicate the direction of the flow. 16
18 Ordering code Flow meter 7000(I)K+F Code 12 METER SIZE 10S SIZE DN10S 010 SIZE DN SIZE DN SIZE DN SIZE DN SIZE DN SIZE DN SIZE DN S8 /8 1/2 /4 1,0 MODEL 5I VFM 7000 INVESTCAST SIZE DN100 SIZE DN150 SIZE DN200 SIZE ANSI /8 S SIZE ANSI /8 SIZE ANSI 1/2 SIZE ANSI /4 SIZE ANSI 1 1,5 2,0,0 4,0 6,0 8,0 SIZE ANSI 1.5 SIZE ANSI 2 SIZE ANSI SIZE ANSI 4 SIZE ANSI 6 SIZE ANSI 8 6 CONSTRUCTION MATERIAL TYPE MATERIAL TYPE A G WAFER, DN25-DN100, ANSI 1-4 SS16L WAFER, DN150, ANSI 6 SS04 H FLANGED, DN25-100, ANSI 1-4 SS16L I FLANGED, DN , ANSI 6-8 SS04 J B C D E F 7 SIZE FOR PRESSURE RATING SIZE FOR A DN200 PN10 K 10S, 10,15, 20, /8 S, /8, 1/2, /4 B DN PN16 L 10S, 10,15, 20, /8 S, /8, 1/2, /4 C DN PN40 M 10S, 10,15, 20, /8 S, /8, 1/2, /4 D DN PN64 N 10S, 10,15, /8 S, /8 E DN25-80 PN100 O 10S, 10,15, /8 S, /8 F LBS P 10S, 10,15, /8 S, /8, 1/2 G LBS Q 10S, 10,15, /8 S, /8, 1/2 H 10S, 10,15, /8 S, /8, 1/2 1/2 NB ANSI 150 R 10S, 10,15, 20, /8 S, /8, 1/2, /4 I 10S, 10,15, /8 S, /8, 1/2 1/2 NB ANSI 00 S 10S, 10,15, 20, /8 S, /8, 1/2, /4 J 10S, 10,15, 20, /8 S, /8, 1/2, /4 /4 NB ANSI 150 T 10S, 10,15, 20, /8 S, /8, 1/2, /4 8 O-RING MATERIAL A VITON O-RING FOR DAMPER PIN B KALREZ 4079 O-RING FOR DAMPER PIN C PAROFLUOR O-RING FOR DAMPER PIN 9 PRESSURE SENSOR RANGE A NOT APPLICABLE B PSIG C PSIG D 0-00 PSIG 10 AREA CLASSIFICATION A CONVERTER CE (NON EX) B CONVERTER EX-CMRI C CONVERTER EX-CSA AND CE D CONVERTER EX-PTB AND CE K L INTEGRAL US/DS, DN10S-20, ANSI /8S -/4 APPLICATION (NON STEAM, -4 TO 56 DEG.F) (NON STEAM, -4 TO 428 DEG.F) (STEAM -4 TO 464 DEG.F) E PSIG F PSIG G 0-50 PSIG H 0-0 PSIG (NOT AVAILABLE WITH FIELD VERSION) (NOT AVAILABLE WITH FIELD VERSION) SS16L PRESSURE RATING /4 NB ANSI 00 1 NB ANSI NB ANSI 00 DN10 PN40 DN10 PN100 DN15 PN40 DN15 PN100 DN20 PN40 DN25 PN40 DN25 PN COMMUNICATION A FREQUENCY OUTPUT B RS22 C RS INTEGRAL/FIELD VERSION A INTEGRAL STANDARD SUPPLY B REMOTE 1 LONG NECK A NOT APPLICABLE B REQUIRED 14 POWER SUPPLY A 100VAC B 110VAC C 120VAC 15 SOFTWARE VERSION A VER 11.7 B VER 12.0A C VER 11.7 NHM FREQUENCY OUTPUT IS STANDARD FREQUENCY OUTPUT NOT AVAILABLE FREQUENCY OUTPUT NOT AVAILABLE TEMP > 02 DEG.F, STANDARD FOR STEAM D 200VAC E 220VAC F 240VAC STANDARD SUPPLY FOR SATURATED STEAM, LIQUIDS, GASES & FAD METERING, NATURAL GAS METERING AS PER AGA 8 FOR NET HEAT METER Additional ordering datas: fluid, operating pressure, temperature, min. & max.flowrate, density and line size. *Please contact KROHNE *FOR FIELD VERSION LONG NECK NOT APPLICABLE E.g. DIN meter: DN80 Sandwich Parafluor O Rings, 110VAC Power Supply, Integral PN40 RS485 communication, CSA marked 080 5I G C C A C C A A B A 17
19 Represented by: Subject to change without notice 000/02-02/499 Forbes Marshall Inc. 101, California Ave, D100, P.O. Box 60670, Palo Alto CA 9406, California, U.S.A. Tel.: , 1467 Fax:
Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.
More informationUFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater
KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for
More informationLow Profile Insertion Vortex
Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free
More informationHot Tap Insertion Vortex
Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and temperature compensation in 2-
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationMultivariable Vortex Flow Meter
Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version
More informationVortex In Line Flow Meter
Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase to each other, resulting
More informationVORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter
R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up
More informationSatellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction
Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid
More informationOPTISWIRL 4070 Technical Datasheet
OPTISWIRL 4070 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Temperature compensation for saturated steam included as standard All OPTISWIRL versions in 2-wire technology
More informationVortex Plate. Model VP General Specification. Product Features
Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals
More informationVortex In Line Flow Meter
Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase
More informationVORTEX IN-LINE FLOW METERS
VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase
More informationModel FVP General Specification. Flanged Vortex Plate. Product Features
Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationSITRANS FX300 4/289. System Overview. Overview
Siemens G 2008 SITRNS F flowmeters Overview System Overview Version Single transmitter Dual transmitter Options Standard Pressure sensor Flange Pressure sensor and isola- Standard tion valve Sandwich vortex
More informationOPTISWIRL 4070 Technical Datasheet
OPTISWIRL 4070 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Temperature compensation for saturated steam included as standard All OPTISWIRL versions in 2-wire technology
More informationVLM20 In-line Vortex Flowmeter
ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration
More informationArmstrong In-Line and Insertion Vortex Flow Meters
Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line
More informationF-2500 SERIES VORTEX METER
F-500 SERIES VORTEX METER APPLICATIONS Saturated steam Hot water to F (0 C) Applications with optional pressure sensor Superheated steam to F (0 C) Compressed air Industrial gases CALIBRATION Each meter
More informationPro-V Multivariable Flowmeter Model M24 In-line Vortex
Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an
More informationPanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits
Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to
More informationSITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application
Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer
More informationVortex Flow Meter Model DVH
Vortex Flow Meter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) p max : 100 bar abs; t max : 400
More informationVersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.
VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet 34-VF-03-05 September 3rd, 2008 Specification The all-in-one solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and
More informationMagnetic-inductive flow meter EPS / UMF2. Technical data sheet
Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding
More informationSITRANS F X SITRANS FX300 3/355
Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure
More informationISTEC MAGNETIC METERS
ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE
More informationF-2600 SERIES INLINE VORTEX FLOW METER
F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)
More informationDVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max
Vortex Flowmeter measuring monitoring analysing DVH Measuring range: 3-8... 3057-280187 Nm³/h Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max : 100 bar abs; t max : 400 C
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationF-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)
F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,
More informationMagnetic-inductive flow meter for hazardous areas
Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials
More informationOPTIMASS 3000 Technical Datasheet
OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless
More informationOPTISWIRL 4200 Technical Datasheet
OPTISWIRL 4200 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Gross and net heat measurement for hot water and steam Stable measurements even under demanding process
More informationVIM20 Vortex Insertion Flowmeter
VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,
More informationInnova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...
Multivariable Mass Vortex Flow Meter Features Volumetric or mass flow monitoring of gases, liquids and steam Smart electronics extends range down to a Reynolds number of 5000 Ideal for steam applications
More informationFlow Measurement SITRANS F X SITRANS FX300 4/365
Siemens AG 200 Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure compensation.
More informationOPTISWIRL 4200 Technical Datasheet
OPTISWIRL 4200 Technical Datasheet Vortex flowmeter Integrated pressure and temperature compensation Development acc. to IEC 61508 edition 2, for SIL2 Gross and net heat measurement for hot water and steam
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series
Digital Vortex meter digitalyewflo Digital Vortex meter Series Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced
More informationOPTIMASS 2000 Technical Datasheet
OPTIMASS 2000 Technical Datasheet Sensor for bulk mass flow Large diameter for bulk measurement and custody transfer of liquids and gases Stainless Steel measuring tubes (NACE Compliant) Modular electronics
More informationVFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification
SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure
More informationRCM - Direct Reading Flowmeters
Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale
More informationInnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION
Multivariable Mass Vortex Flow Meter FEATURES Mass and volumetric flow measurement of gas, liquid, and steam Multivariable outputs for five process parameters: mass flow rate volumetric flow rate temperature
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationDesign and application
Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationSIGNET 7002 Vortex Flow Sensor ENGLISH
SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility
More informationVIM20 Vortex Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage
More informationGA 24 Heavy-duty variable area flowmeter
KROHNE 10/99 D 11 GA24 01 E GR Heavy-duty variable area flowmeter Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationNON-RETURN VALVE RT25
NON-RETURN VALVE RT25 DESCRIPTION The RT25 all stainless steel disc check valve has a compact design and was specially designed for use with steam and hot condensate. Connections are female screwed MAIN
More informationSentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter
GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas
More informationORIMAS Mass Flowmeter
Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical
More informationRIM20 Rotor Insertion Flowmeter
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSTEEMCO-MAS Flowmeter for Steam
STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationSTEEMCO Flowmeter for Steam
STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Vortex multivariable meters from Azbil North America employ three sensing elements in
More informationEGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationVolumeter. RMG Meßtechnik GmbH. Publication No E
Volumeter TRZ 03-K RMG Meßtechnik GmbH Publication No. 3.171-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationVolumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas
Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate
More informationMicro Motion F-Series Coriolis Flow and Density Meters
Product Data Sheet PS-00603, Rev. F December 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density
More informationThe EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.
Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power
More information유량계전문제조업체. Electro Magnetic FLOWMETER
유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged
More informationVortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1
Vortex Flow Sensors VA Di Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases Drawing 1 Measurable variable actual flow rate standard velocity standard flow
More informationVortex Flowmeter Model DVE
Vortex Flowmeter Multi-Parameter measuring monitoring analysing DVE Measuring range Liquids: 5.2-157... 284-85371 m³/h Air: 89-1463... 26915-2467081 Nm 3 /h (20 C, 0 bar rel) Saturated steam: 81-938...
More informationManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:
KMS501W & KMS502F- TW FEATURES: Fitted with Sydney Water Tradewaste plugs (Sampler and ma outputs). For waste water, bore water and irrigation ( upto 10% solids). Unsurpassed accuracy to ±0.5% 0.5 m/s
More information7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel
KROHNE 04/2004 7.02445.24.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel Status: 10/99 Status: 10/99 One tube no limits No limits with
More informationTransmitting Transducer. Gas/Air Velocity Range:
RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Digital Vortex meter digitalyewflo Digital Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/ Series Simple body construction for easy installation and high level of safety 2 3 Standard Type /
More informationRosemount 8800D Series Vortex Flowmeter
Product Data Sheet HART AND FOUNDATION FIELDBUS PROTOCOLS Available with optional MultiVariable output and temperature compensated mass flow for saturated steam. Available in wafer, flanged, dual, reducer
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.
More informationPoint level measurement Capacitance switches
Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.
More informationElectromagnetic flowmeters for water and seewage
09/97 Electromagnetic flowmeters for water and seewage Primary head Compact flowmeters Installation instructions AQUAFLUX F 0 K 020 K 080 K CONTENTS Storage and transport Pagesn 3-4 Installation in the
More informationLCMass Series Mass Flow Sensor
LCMass 100-140 Series Mass Flow Sensor Technical Data Sheet HIGH ACCURACY The LCMass 100 achieves a ±0.15% accuracy on liquids. COMPACT ECONOMIC DESIGN Straight twin-tube design allows for an overall smaller
More informationThe readings you need, right where you need them. AX Series Vortex Meters
The readings you need, right where you need them. AX Series Vortex Meters Multivariable function from a single meter Principles of Operation Vortex multivariable meters from Azbil North America employ
More informationFH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications
FH85 Metering Solution for Custody Transfer Applications One Step Ahead in Ultrasonic Flowmetering Main Applications Oil Production & Allocation FSO, FPSO Metering Tanker Off-loading Storage Management
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationKDM ARMORED FLOW METER & SWITCH
KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature
More informationLevel Measurement Point level measurement - RF Capacitance switches
Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable
More informationRMG Meßtechnik GmbH. Publication No E
Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationTurbine flowmeters Series TM
Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationSeries 8000 Vortex Flow Meter
VFM Series 8000 Vortex Flow Meter Operating Principle The operation of the VFM 8000 is based on the Karman Vortex Street. Vortices are formed as the fluid flows around the shedder body which are alternately
More informationProduct Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date
FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced
More informationElectromagnetic flowmeters
02/97 Electromagnetic flowmeters Primary heads Installation instructions ECOFLUX IFS 1000 F Compact flowmeters IFM 1010 K IFM 1080 K CONTENTS Installation in the pipeline Pages 4-5 and 7-8 Grounding Pages
More informationActuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage
Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact
More informationInline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )
EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the
More information9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER
Design Specifications DS-9900 Revision 04 9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER 2-Wire loop powered flowmeter/transmitter 316 Stainless steel measuring unit Automatic temperature
More informationLiquid Turbine Flow Meter OwnerÊs Manual
Liquid Turbine Flow Meter OwnerÊs Manual Manual LWGY-G Rev.1.0 Content 1.0 GENERAL INFORMATION... 1 2.0 SPECIFICATIONS... 2 3.0 OPERATION CONDITIONS... 3 4.0 CAUTIONS FOR INSTALLATION... 4 5.0 DIMENSION...
More informationSeries Level-Trol Electronic Liquid Level Transmitters
0- Level-Trol Series 0- Series Level-Trol Electronic Liquid Level Transmitters W0-/IL Non-Interactive Zero and Span Adjustments; Dry Span Calibration Allows Field Recalibration without Removing Wiring
More informationVortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Vortex meter digitalyewflo Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/fld Series Simple body construction for easy installation and high level of safety 2 Standard Type / Multi-variable
More informationSATRON VVFe Pressure Transmitter
SATRON VVFe pressure transmitter belongs to Vtransmitter family. SATRON VVFe is used for 0 4 kpa...0500 kpa ranges. It is a 2wire transmitter with HART standard communication. SATRON VVFe pressure transmitter
More informationMEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter
MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic
More informationThermal Gas Mass Flowmeter Series TMF-300
Thermal Gas Mass Flowmeter Series TMF-300 Technical Superiorities a true mass flow meter which could measure the gas flow conveniently and accurately without compensation for temperature or pressure. Mass
More information