INDUSTRIAL DIRECT DRIVE 20 Positive Indirect Gas Heated Air Curtain Data Sheet

Size: px
Start display at page:

Download "INDUSTRIAL DIRECT DRIVE 20 Positive Indirect Gas Heated Air Curtain Data Sheet"

Transcription

1 For Mounting Heights To 20 (environmental separation) STANDARD CONSTRUCTON Single speed T.E.A.O. motor(s) - direct drive Gray powder coated exterior (Optional: Custom Color or Stainless) Split cabinet construction for fan assembly removal Top Mounting only Front air intake only High efficiency Pro-V Nozzle NDUSTRAL DRECT DRVE 20 Positive ndirect Gas Heated Air Curtain Data Sheet Factory mounted duct transition with bottom access panels Field installed cetlus AHR Certified indirect gas heater(s): Aluminized steel heat exchanger (Optional: Stainless) Steel cabinet with beige finish Spark ignited pilot Power venter Separate 120V power supply required (Optional: transformer for single point connection) Nozzle Width (in) Max Vel. at Nozzle (fpm) Avg. Outlet Vel. (fpm) Air Volume (cfm) Outlet Vel. Uniformity Power Rating (kw) NOTES: 1. Operation at 50 Hz will generate approximately a 17% reduction in performance. 2. Performance data based on AMCA licensed data from unheated units. 3. Maximum leaving air temperature shall not exceed 120 F. 4. Duct transition is factory mounted to air curtain and requires individual support. 5. Gas heater(s) shall not be directly connected to transition and require individual support. 6. Maximum gas supply pressure: 1/2 psi, 8 ounces, or 14 inches water column. 7. Vertically mounted indirect gas heated air curtain not available. See sheet EP-448 for amp draws/total load requirements. Total Heater(s) Motor(s) hp Output (MBH) (MBH) Air Temp. Rise ( F) 2 Year Limited Warranty Net Wt. Air Curtain (lbs) Net Wt. Duct Trans. (lbs) DC G ,580 3,655 6,854 89% DC G ,549 3,852 8,186 89% DC G ,076 3,574 8,861 87% Net Wt. Heater (lbs) DC G ,900 4,059 11,500 92% ½ DC G ,747 3,969 12,650 90% ½ DC G ,494 4,523 15,612 88% DC G ,017 4,127 16,080 87% DC G ,640 4,381 19,100 87% DC G ,405 4,356 20,055 86% DC G ,783 4,323 22,700 90% , DC G ,300 4,294 22,814 91% , DC G ,900 4,059 23,000 92% ½ , NUMBER CONFGURATON DC G D-F SS Series DC20 # of Motors 1, 2 Opening Width Heat G=ndirect Gas Heated Voltage D=208/3/60 E=240/3/60 H=480/3/60 =600/3/60 T=380/3/50 ntake F=Front Opt. Cabinet Finish SS=Stainless Steel CC=Custom Color Sound level measured 10 (3m) from the unit in free field: 3, 5, 7½, (5 + 3) (5 + 5) hp motor(s): 68 dba, 70 dba, 71 dba, 72 dba 73 dba Berner nternational DS-448 July, 2017 Copyright, 2017 Berner nternational

2 NDUSTRAL DRECT DRVE 20 Positive ndirect Gas Heated Air Curtain Electrical Performance Sheet 208/3/60 (voltage code D) AMP DRAW PER HP MULTPLE CKT - PANEL SNGLE CKT - PANEL XFMR FOR HTR. MBH Temp Rise F HP # 208V CKT PER CRCUT # 208V CKT XFMR KVA (including XFMR) PER CRCUT DC G DC G DC G DC G / / DC G / / DC G / / DC G / / DC G / / DC G / / DC G /9.0/ /15/ DC G /9.0/ /15/ DC G /9.0/ /15/ Page 1 of 5 Berner nternational Corporation EP-448 June, 2015 Copyright, 2015 Berner nternational Corporation

3 NDUSTRAL DRECT DRVE 20 Positive ndirect Gas Heated Air Curtain Electrical Performance Sheet 240/3/60 (voltage code E) AMP DRAW PER HP MULTPLE CKT - PANEL SNGLE CKT - PANEL XFMR FOR HTR. MBH Temp Rise F HP # 240V CKT PER CRCUT 240V CKT # XFMR KVA (including XFMR) PER CRCUT DC G DC G DC G DC G / / DC G / / DC G / / DC G / / DC G / / DC G / / DC G /9.0/ /15/ DC G /9.0/ /15/ DC G /9.0/ /15/ Page 2 of 5 Berner nternational Corporation EP-448 June, 2015 Copyright, 2015 Berner nternational Corporation

4 NDUSTRAL DRECT DRVE 20 Positive ndirect Gas Heated Air Curtain Electrical Performance Sheet 480/3/60 (voltage code H) AMP DRAW PER HP MULTPLE CKT - PANEL SNGLE CKT - PANEL XFMR FOR HTR. MBH Temp Rise F HP # 480V CKT PER CRCUT # 480V CKT XFMR KVA (including XFMR) PER CRCUT DC G DC G DC G DC G / / DC G / / DC G / / DC G / / DC G / / DC G / / DC G /9.0/ /15/ DC G /9.0/ /15/ DC G /9.0/ /15/ Page 3 of 5 Berner nternational Corporation EP-448 June, 2015 Copyright, 2015 Berner nternational Corporation

5 NDUSTRAL DRECT DRVE 20 Positive ndirect Gas Heated Air Curtain Electrical Performance Sheet 600/3/60 (voltage code ) AMP DRAW PER HP MULTPLE CKT - PANEL SNGLE CKT - PANEL XFMR FOR HTR. MBH Temp Rise F HP # 600V CKT PER CRCUT # 600V CKT XFMR KVA (including XFMR) PER CRCUT DC G DC G DC G DC G / / DC G / / DC G / / DC G / / DC G / / DC G / / DC G /9.0/ /15/ DC G /9.0/ /15/ DC G /9.0/ /15/ Page 4 of 5 Berner nternational Corporation EP-448 June, 2015 Copyright, 2015 Berner nternational Corporation

6 NDUSTRAL DRECT DRVE 20 Positive ndirect Gas Heated Air Curtain Electrical Performance Sheet 380/3/50 (voltage code T) AMP DRAW PER HP MULTPLE CKT - PANEL SNGLE CKT - PANEL XFMR FOR HTR. MBH Temp Rise F HP # 380V CKT PER CRCUT # 380V CKT XFMR KVA (including XFMR) PER CRCUT DC G DC G DC G DC G / / DC G / / DC G / / DC G / / DC G / / DC G / / DC G /9.0/ /15/ DC G /9.0/ /15/ DC G /9.0/ /15/ Page 5 of 5 Berner nternational Corporation EP-448 June, 2015 Copyright, 2015 Berner nternational Corporation

7 0.75 TYP [1.91] OPTONAL - PANEL ffi u_ 1 CONTROL -t- TOP VEW c UNT \JDTH - C MOUNTNG \./DTH - "B" < DC20 NDRECT GAS HEATED ONE SYSTEM FRONT NTAKE NOTES: AR CURTAN MUST BE NSTALLED SD AR STREAM S NOT OBSTRUCTED WHEN DEFLECTED 20 TD ETHER SDE OF ll_: ELECTRCAL CONNECTONS TD EE FLEXBLE MOUNTNG HOLES CTYP 6) TRANSTON \JTH ACCESS DUCT PANELS "tt ;:=="="="=":c="="="=============i:=:;: FELD VERFY DMENSONS, ANCHORS TD SUPPORTNG STRUCTURE BY OTHERS ADEQUACY OF SUPPORTNG STRUCTURE S TD BE VERFED BY A PRDFTSSDNAL STRUCTURAL ENGNEER. 3/8-16 FEMALE THREADS ELECTRCAL SUPPLY [104.46] T" FRONT VEW --- \./DTH-D G LETTER G N NUMBER DESGNATES, POSTVE NDRECT GAS HEATED UNT. THE F DESGNATES FRONT NTAKE. OPTONAL CONTROL PANEL AVALABLE: LEFT HAND MOUNT, RGHT HAND MOUNT, DR REMOTE. PLEASE SPECFY. SUPPLY PRESSURES HGHER THAN 0.50 POUND REQURE NSTALLATON OF AN ADDTONAL SERVCE REGULATOR EXTERNAL TD THE UNT. DMENSONS N NCHES CCENTMETERSJ. END VEW f DEPTH-!, DEPTiiJM f i:o:j [50.80] --1 MJN [3 81] [81.91] 3/4 GAS CONNECTON CNDT SUPPLY LNE SZEJ NOZZLE ANGLE CONTROL BOTTOM VEW DAMPER CONTROL SUPPORT UNT SEPARATE FROM AR CURTAN ADJUST LOUVERS TD 0 rno RDT ATDN c-, ---i_-\-_ 1 J_l ONE JUNCTON BOX PER (STANDARD FDR REMOTE PANEL) 2.75 x 4.50 x 2.00 AJR L.H. STANDARD, R.H. OPTONAL FLD\J CAUTON: FOR NDZZLE \JDTH - A DMENSONS SEE DWG. #DC20-GF4 DC G-F DC G-F DC G-F TOTAL ND. MBTU NPUT 345 l " 345 l " 345 S EQUPPED FDR A MAXMUM GAS SUPPLY PRESSURE OF 1/2 POUND, 8 DUNCES, DR 14 NCHES \JATER COLUMN. PROJECT LOCATON ARCHTECT ENlilNEER D\o/G, ND. DC20-GF1 DATE 09JUNE14 BY S. Beil REPLACES - nm BERNER OC20 AR CURTAN NDRECT GAS FRED - ONE SYSTEM BERNER NTERNATONAL CORP NEo/ CAOTLE,PA

8 o- DPTDNAL :: 1 CONTROL {hr-, - PANEL ffi u_ TOP VEW c unt \o/dth - C [.;] MOUNTNG \o/dth - "B" "1 +=i=-t DC20 NDRECT GAS HEATED TWO SYSTEM FRONT NTAKE NOTES: AR CURTAN MUST BE NSTALLED SD AR STREAM S NOT OBSTRUCTED WHEN DEFLECTED 20 TD ETHER SDE OF ll_: ELECTRCAL CONNECTONS TD EE FLEXBLE MOUNTNG HOLES CTYP 6l TRANSTON DUCT 1t -;:c="="=":::c="="===;---_:_---=;:::;:="="="=":::2="=""==":;---_j---- \./TH ACCESS PANELS - 3/8-16 FEMALE THREADS CTYPJ ELECTRCAL SUPPLY CTYPJ _J_ [[04.46] 3/8-16 \VELDED NUTS CTYPl FELD VERFY DMENSONS, ANCHORS TD SUPPORTNG STRUCTURE BY OTHERS ADEQUACY OF SUPPORTNG STRUCTURE S TD BE VERFED BY A PRDFTSSDNAL STRUCTURAL ENGNEER. LETTER G N NUMBER DESGNATES, POSTVE NDRECT GAS HEATED UNT. THE F DESGNATES FRONT NTAKE. OPTONAL CONTROL PANEL AVALABLE: LEFT HAND MOUNT, RGHT HAND MOUNT, DR REMOTE. PLEASE SPECFY. SUPPLY PRESSURES HGHER THAN 0.50 POUND REQURE NSTALLATON OF AN ADDTONAL SERVCE REGULATOR EXTERNAL TD THE UNT. DMENSONS N NCHES CCENTMETERSJ. 3/4 GAS CONNECTON CTYPJ CNDT SUPPLY LNE SZEl FLUE DAMETER - J CTYPJ CCRCLJLAR ADAPTER PRDVDEDl -c- CTYPl FRONT VEW DCTYPJ END VEW C DEPTH-"!" G 1 :f :] ;:Jt =129 CFi====i==i 1-- [3 Bll FOR o " u_ ZLE ANGLE CONTROL / " DMENSONS BOTTOM VEW NOZZLE \JDTH - A DAMPER CONTROL / SEE DWG. #DC20-GF4 0 TT -i t DC G-F DC G-F DC G-F DC G-F DC G F DC G F TOTAL ND. MBTU NPUT i--<---i----+-; FAN(\ RDT 1 TDN ) c-, -----;_-\-_ l J l_ SUPPORT UNT SEPARATE FROM AR CURTAN ADJUST LOUVERS TD 0-0 ONE JUNCTON BOX PER (STANDARD FDR REMOTE PANEL) 2.75 x 4.50 x 2.00 AJR L.H. STANDARD, R.H. OPTONAL FLD\J CAUTON: S EQUPPED FDR A MAXMUM GAS SUPPLY PRESSURE OF 1/2 POUND, 8 DUNCES, DR 14 NCHES WATER COLUMN. PROJECT LOCATON ARCHTECT ENlilNEER D\o/G, ND. DC20-GF2 DATE 09JUNE14 BY S. Beil REPLACES - nm BERNER OC20 AR CURTAN NDRECT GAS FRED - TWO SYSTEM BERNER NTERNATONAL CORP NEo/ CAOTLE,PA

9 0.750 [1.9 ll -t- o- DPTDNAllis CONTROL -t- PANELffi " u_ HOLES CTYP 6) MOUNTNG 3/8-16 WELDED NUTS <TYP) ELECTR SUP PLY CAL 0 CT YPJ t -- FLUE DAMETER - J <TYP) CCRCULAR ADAPTER PROVDED).-- od D ffi Cl ci om ru _L i CTYP) - - -c- TOP VEW UNT WDTH - -c- MOUNTNG \VDTH - \./TH ACCESS PANELS TRANSTON DUCT--..., s B 3/8"-16 FEMALE ru THREAD CTYP) -m - ru j t -- t rj - WDTH FRONT VEW [ L CTYPl [104.46]- -- r) MOUNTNG i----- WDTH - E DCTYP) CTYPl DC20 NDRECT GAS HEATED THREE SYSTEM FRONT NTAKE NOTES: AR CURTAN MUST BE NSTALLED SD AR STREAM S NOT OBSTRUCTED WHEN DEFLECTED 20 TD ETHER SDE OF ll_: ELECTRCAL CONNECTONS TD EE FLEXBLE. FELD VERFY DMENSONS, ANCHORS TD SUPPORTNG STRUCTURE BY OTHERS ADEQUACY OF SUPPORTNG STRUCTURE S TD BE VERFED BY A PROFESSONAL STRUCTURAL ENGNEER. LETTER G N NUMBER DESGNATES, POSTVE NDRECT GAS HEATED UNT. THE F DESGNATES FRONT NTAKE. OPTONAL CONTROL PANEL AVALABLE: LEFT HAND MOUNT, RGHT HAND MOUNT, DR REMOTE. PLEASE SPECFY. SUPPLY PRESSURES HGHER THAN 0.50 POUND REQURE NSTALLATON OF AN ADDTONAL SERVCE REGULATOR EXTERNAL TD THE UNT. DMENSONS N NCHES CCENTMETERSJ. END VEW DEPTH-"" G :T2H coo oij f :129 [19 37] t-= 150 MN [3 81] o " U--ttJ;;;::::::::::::::::::::::::::::::::::::t:::;:::::::::::::::::::::::::::::::::::::±::::::::::::::::::::::::::::::::::::::::::=±l-1=--l_l --- BOTTOM VEW 3/4 GAS CONNECTON <TYPl <NOT SUPPLY LNE SZEl,N:ZLE "" ANGLE CONTROL DAMPER CONT FOR DMENSONS SEE DWG. #DC20-GF4 SUPPORT UNT SEPARATE FROM AR CURTAN TOTAL ND. MBTU NPUT DC G-F 345 DC20 ll80g F 345 DC G F 345 J====fL_3": J_J_ ADJUST LOUVERS TD 0 ONE JUNCTON BOX PER CSTANDARD FDR REMOTE PANEL) 2.75 x 4.50 x 2.00 AR L.H. STANDARD, R.H. OPTONAL FLO\./ CAUTON: S EQUPPED FDR A MAXMUM GAS SUPPLY PRESSURE OF 1/2 POUND, 8 DUNCES, DR 14 NCHES \./ATER COLUMN. PROJECT LOCATON ARCHTECT ENlilNEER D\o/G, ND. DC20-GF3 TTLE BERNER DATE 09JUNE14 OC20 AR CURTAN BY S. Beil NDRECT GAS FRED - THREE SYSTEM REPLACES - BERNER NTERNATONAL CORP NEo/ CAOTLE,PA D D D c:

10 D c 2 0 NDRECT GAS HEATED TOTAL ND. MD DEL NOZZLE \./DTH MOUNTNG \./DTH UNT \./DTH \./DTH \JDTH \JDTH DEPTH DEPTH DEPTH FLUE DEPTH \./DTH A B c METU NPUT D c T G w r J.,. L DC G-F [152.40J [156.21l [27.31J [101,60J [43.02] 3.69 [9,37J [[04.46] [240.98] 6.00 [15,24] 3.50 [8,89] - DC G F [182.88] [186.69] [42.55] [101,60] [43.02] 3.69 [9,37J [[04.46] [240.98] 6.00 [15,24] 3.50 [8,89] - DC G-F [213.36] [217.17] [57.79] [101.60] [43.02] 3.69 [9,37J [[04.46] [240.98] 6.00 [15,24] 3.50 [8,89] - DC G-F [243.84] [247.65] [251.46] [12,07J [101.60J [43.66] 3.69 [9,37J [101.60J [238.13] 5.00 [12,70] 3.50 [8,89] 8.00 [20.32] DC G c [274.32] [278.13] [281.94] [19.69] [101,60J [43.66] 3.69 [9,37J [101,60] [238.13] 5.00 [12,70] 3.50 [8,89] [35.56] DC G c [297.18] [300.99] [304.80] [25.40] [101,60] [43.02] 3.69 [9,37J [104.46] [240.98] 6.00 [15,24] 3.50 [8,89] [46.99] DC G c [335.28] [339.09] [342.90] [34.93] [101.60J [43.02] 3.69 [9.37J [[04.46] [240.98] 6.00 [15.24] 3.50 CB.89J [66.04] DC G-F [365.76] [369.57] [373.38] [42.55] [101,60J [43.02] 3.69 [9,37J [[04.46] [240.98] 6.00 [15,24] 3.50 [8,89] [81.28] DC G-F [396.24] [400.05] [403.86] [50.17] [101,60] [43.02] 3.69 [9,37] [104.46] [240.98] 6.00 [15,24] 3.50 [8,89] [96.52] DC G F [426.72] [430.53] [434.34] [22.23] [101.60] [43.02] 3.69 [9.37] [104.46] [240.98] 6.00 [15.24] 3.50 CB.89J [40.64] DC G-F [457.20] [461.0lJ [464.82] [27.31J [101,60] [43.02] 3.69 [9,37] [104.46] [240.98] 6.00 [15,24] 3.50 [8,89] [50.80] DC G F [487.68] [491.49] [495.30J [32.39] [101.60] [43.02] 3.69 [9,37] [104.46] [240.98] 6.00 [15,24] 3.50 [8,89] [60.96] NOTES: AR CURTAN MUST BE NSTALLED SD AR STREAM S NOT OBSTRUCTED \./HEN DEFLECTED 2D TD ETHER SDE OF t_. ELECTRCAL CONNECTONS TD BE FLEXBLE. FELD VERFY DMENSONS, ffi ANCHORS TD SUPPORTNG STRUCTURE BY OTHERS. ADEQUACY OF SUPPORTNG STRUCTURE S TD BE VERFED BY A PROFESSONAL STRUCTURAL ENGNEER. LETTER G N NUMBER DESGNATES, POSTVE NDRECT GAS. UNT. THE F DESGNATES FRONT NTAKE. ffi OPTONAL CONTROL PANEL AVALABLE: LEFT HAND MDU NT, PROJECT RGHT HAND MOUNT, DR REMOTE. PLEASE SPECFY. LOCATON SEP FURNACES HAVE T\JD FANS AND FOUR MOUNTNG PONTS. ARCHTECT ENlilNEER SUPPLY PRESSURES HGHER THAN 0.50 POUND REQURE NSTALLATON D\o/G, ND. DC20-GF4 TTLE OF AN ADDTONAL SERVCE REGULATOR EXTERNAL TD THE UNT. BERNER DATE 09JUNE14 OC20 AR CURTAN Mi DMENSONS N NCHES CCENTMETERSJ. s. Beil NDRECT GAS FRED SYSTEM " REPLACES BERNER NTERNATONAL CORP " - NEo/ CAOTLE,PA

INDUSTRIAL BELT DRIVE 16 Positive Indirect Gas Heated Air Curtain Data Sheet

INDUSTRIAL BELT DRIVE 16 Positive Indirect Gas Heated Air Curtain Data Sheet For Door Heights To 16 (environmental separation) STANDARD CONSTRUCTION Single speed T.E.F.C. motor - belt drive Gray powder coated exterior (Optional: Custom Color or Stainless) Split cabinet construction

More information

INDUSTRIAL DIRECT DRIVE 12 Positive Indirect Gas Heated Air Curtain Data Sheet

INDUSTRIAL DIRECT DRIVE 12 Positive Indirect Gas Heated Air Curtain Data Sheet For Door Heights To 12 (environmental separation) INDUSTRIAL DIRECT DRIVE 12 Data Sheet STANDARD CONSTRUCTION ½ hp single speed motor(s) - direct drive (Optional: three-speed) Gray powder coated exterior

More information

INDUSTRIAL DIRECT DRIVE 14 Positive Indirect Gas Heated Air Curtain Data Sheet

INDUSTRIAL DIRECT DRIVE 14 Positive Indirect Gas Heated Air Curtain Data Sheet For Mounting Heights To 14 (environmental separation) STANDARD CONSTRUCTION 1 hp single speed motor(s) - direct drive (Optional: two-speed) Gray powder coated exterior with mill aluminum screen and access

More information

INDUSTRIAL DIRECT DRIVE 20 Electric Heated Air Curtain Data Sheet

INDUSTRIAL DIRECT DRIVE 20 Electric Heated Air Curtain Data Sheet For Mounting Heights To 20 (environmental separation) Data Sheet STANDARD CONSTRUCTION Single speed T.E.A.O. motor(s) - direct drive Gray powder coated exterior (Optional: Custom Color or Stainless) Split

More information

Compact Motor Geared Motors

Compact Motor Geared Motors Compact Geared s Compact CIM-2.01GB0914 PRODUCTS IN THE RANGE Servng an entre spectrum of mechancal drve applcatons from food, energy, mnng and metal; to automotve, aerospace and marne propulson, we are

More information

WAC Air Curtains Technical Guide

WAC Air Curtains Technical Guide TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2

More information

Vertical Unit Heaters Submittal

Vertical Unit Heaters Submittal Vertical Heaters Submittal VVSD-5 Dimensional Data FGURE A FGURE B FGURE A MODEL VV UNT HEATER ROUGHNG-N DMENSONS 40 62 Fan Diam 11 1 / 4 1 1 A 1 1 / 4 21 1 / 4 21 1 / 4 B 4 5 / 4 5 / 6 1 / C 1 1 / 4 1

More information

SpaceStation TM. Installation Instructions SpaceStation Occupancy Lighting Control System. Please Save These Instructions

SpaceStation TM. Installation Instructions SpaceStation Occupancy Lighting Control System. Please Save These Instructions Phone: 605.542.4444 concealte.com! Installaton SpaceStaton Occupancy Lghtng Control System Please Save These Important Safeguards Read and Follow All Safety þdo not use outdoors. þdo not let power supply

More information

SERIES 2000 TEMPERATURE REGULATOR SERIES 2000 TEMP. REGULATOR. SIZES 1/2" 2" CONTROLS -25 to 400 F

SERIES 2000 TEMPERATURE REGULATOR SERIES 2000 TEMP. REGULATOR. SIZES 1/2 2 CONTROLS -25 to 400 F SERES 2000 TEMP. SERES 2000 TEMPERATURE APPLCATON DATA DRECT ACTNG Bottle Washing Machinery Steam Tables Plating Tanks Heating Ducts Fuel Oil Heaters Cooking Vats Water Heaters Heat Exchangers Parts Washer

More information

General Description. Construction

General Description. Construction Sheet 0 General Descrpton.- MEB Metal-Enclosed Drawout General Descrpton Eaton s Cutler-Hammer MEB (Metal- Enclosed ) conssts of a sngle hgh drawout vacuum crcut breaker (Type VCP-W) n a metal-enclosed

More information

Open Your Doors to Berner. Berner Industrial. The Nation s Original Air Door Manufacturer

Open Your Doors to Berner. Berner Industrial. The Nation s Original Air Door Manufacturer Open Your Doors to Berner Berner Industrial AIR DOORS The Nation s Original Air Door Manufacturer 800-245-4455 www.airdoors.com how a berner air door works Activation Devices for Air Doors Plunger Style

More information

BERNER AIR CURTAINS. The Energy Saving DOORWAY SOLUTION for Comfort & Safety. MADE in USA For Over 60 Years

BERNER AIR CURTAINS. The Energy Saving DOORWAY SOLUTION for Comfort & Safety. MADE in USA For Over 60 Years BERNER AIR CURTAINS The Energy Saving DOORWAY SOLUTION for Comfort & Safety MADE in USA For Over 60 Years 8002454455 wwwbernercom Not seeing your application? Talk with Berner - 8002454455 DRIVE-THRU UNIT

More information

AXO Adjustable Vanes High Induction Swirl Diffusers

AXO Adjustable Vanes High Induction Swirl Diffusers Ar Dffuson 13 AXO Adjustable Vanes Hgh Inducton Swrl Dffusers H V A C TM Archtecture, Comfort, Effcency Rev 27-05-2018 Ar Dffuson 14 AXO SEres Adjustable Vanes Round Swrl Dffusers Indvdually adjustable

More information

PENDANT FORMS - INDIRECT

PENDANT FORMS - INDIRECT PENDANT FORMS - NDRECT Project Type Notes ndirect A ndirect Asymmetric lank A configuration drawing is required Factory is available for assistance See page 2 for example of how to specify Ordering Guide

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

Gas-Fired Separated Combustion Unit Heaters Propeller & Blower Models

Gas-Fired Separated Combustion Unit Heaters Propeller & Blower Models 6-75. September, 2008 Gas-Fired Separated Combustion Unit Heaters Propeller & Blower Models MODEL HDS MODEL HDC MODEL PTS (shown) / BTS 6-75. TABLE OF CONTENTS Modine s separated combustion unit heaters

More information

Metal-Enclosed Switchgear MEB & MSB Medium Voltage Switch and Fixed Mounted Vacuum Breakers (MSB) MSB Metal-Enclosed Switch and Vacuum Breaker

Metal-Enclosed Switchgear MEB & MSB Medium Voltage Switch and Fixed Mounted Vacuum Breakers (MSB) MSB Metal-Enclosed Switch and Vacuum Breaker June 0 Sheet 0 Metal-Enclosed Swtchgear MEB & MSB Medum Voltage Swtch and Fxed Mounted Vacuum s (MSB) General Descrpton.- MSB Metal-Enclosed Swtch and Vacuum General Descrpton Eaton s Cutler-Hammer assembly

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Product Information. Universal swivel finger GFS

Product Information. Universal swivel finger GFS Product Informaton GFS GFS Productve. Flexble. Compact. GFS unversal rotary fnger Rotary fnger for turnng workpeces that are held by a grpper or can also be used as a specal swvel unt. Feld of applcaton

More information

Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS Trip Units

Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS Trip Units nstruction Leaflet L29C714L Supersedes L 29C714K Dated 01/12 Circuit Breaker with DGTRP RMS Trip Units nstruction Leaflet L29C714L Circuit Breaker with DGTRP RMS Trip Units LNE 1 2 3 NDEX DAGRAMS TRP UNT

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER L (Housing Arr. H) 4" 6" A=Blower B=Filter C=Intake Downturn Plenum W Intake damper (Optional) H Birdscreen " Curb Cap D Electrical connection H Housing V-bank filters intake hood Gas connection E Lifting

More information

RTMR ORDERING OPTIONS

RTMR ORDERING OPTIONS RTMR ORDERING OPTIONS There are many dfferent ways to order the RTMR block and matchng accessores. You can buy ndvdual parts separately so you can mx & match to sut your exact requrements, or you can buy

More information

Mobile fence. Road construction. Event. Mobile fence e. Building construction. Civil engineering. Storage equipment. Transport equipment

Mobile fence. Road construction. Event. Mobile fence e. Building construction. Civil engineering. Storage equipment. Transport equipment e 48 Urban Equpment Buldng Equpment Standard as barrer around constructon stes, moble fence pre-galvanzed, wth tubular frame all around, vertcal tubes Ø 42.4 mm, horzontal tubes Ø 26.9 mm, mesh sze: vertcal:

More information

Effective for units with serial numbers beginning with EC1D & WR1D. Wiring Diagrams

Effective for units with serial numbers beginning with EC1D & WR1D. Wiring Diagrams ECMT & WRMT Hoists with Motorized Trolley (Small Frame Hoist) Effective for units with serial numbers beginning with ECD & WRD. Serial numbers are stamped under the hoist on the transmission housing. Changes

More information

Comfort. Description. Applications

Comfort. Description. Applications Blower Heater 3-35 kw 10,236-119,420 Btuh 208, 240, 480 and 575 Volt 1 or 3 Phase Built-in Controls Description Type is designed to heat areas classified as hazardous locations to provide primary or supplementary

More information

"""" II. W r------" LEFT SIDE VIEW

 II. W r------ LEFT SIDE VIEW THS PANEL S CONSRUClED Wmt PERFORATD MATERW. 500 CLEARANCE FOR VENTATON l -- 1070 i MNM UM SERVCE CUARANCE PER i--nat ONAL, STAlE-- &; LOCAL CODES - FRO NT 991 so """" 102 3 SDE BRACES 825 2 p ACES L!

More information

EZ Rider HPt *330825* Service Information Rev. 00. The safe scrubbing alternativet. Patents Pending

EZ Rider HPt *330825* Service Information Rev. 00. The safe scrubbing alternativet. Patents Pending EZ Rder HPt Servce Informaton Patents Pendng The safe scrubbng alternatvet 085 Rev. 00 *085* Ths manual provdes servce nformaton for the NOBLES Model EZ Rder HP. Ths machne wll provde excellent servce.

More information

R 1000 Modular shelving system

R 1000 Modular shelving system MODULAR SHELVING SYSTEMS GALVANISED LIGHT GREY RAL 7035 RAL 7035 R 1000 Modular shelvng system The advantages of modular shelvng from SSI SCHAEFER are mpressve: Closed sold sde panels prevent stored goods

More information

1.15 Instrument Cluster (IC) Contents

1.15 Instrument Cluster (IC) Contents 1.15 Instrument Cluster (IC) Contents 1.15 Model 163 (as of M.Y. 1998) wth FSS Dagnoss Functon Test................................... 11/1 Dagnostc Trouble Code (DTC) Memory................ 12/1 Complant

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

PGC COMMERCIAL PACKAGED GAS/ELECTRIC PGC COMMERCIAL PACKAGED GAS/ELECTRIC PRODUCT SPECIFICATIONS 7½ TO 10 TON 10.3 EER COOLING CAPACITY 86,000-116,000 BTU/H HEATING CAPACITY 193,000-225,000 BTU/H The Goodman PGC Commercial Packaged Gas/Electric

More information

GAS-FIRED SEPARATED COMBUSTION UNIT HEATERS

GAS-FIRED SEPARATED COMBUSTION UNIT HEATERS GASFIRED SEPARATED COMBUSTION UNIT HEATERS MODEL HDS MODEL HDC MODEL PTS / BTS 675.7 MAY, 207 TABLE OF CONTENTS Modine s separated combustion unit heaters are designed for the heating requirements of commercial

More information

VTS-2 CARPARX. Parking Automation Systems Inc 1010 Arlee Place, Anaheim, CA Two-level Dual-Platform Vehicle Transport System

VTS-2 CARPARX. Parking Automation Systems Inc 1010 Arlee Place, Anaheim, CA Two-level Dual-Platform Vehicle Transport System Two-level Dual-Platform Vehicle Transport System Parking Automation Systems nc 1010 Arlee Place, Anaheim, CA 714-267-0155 Technology for Enhanced Vehicle Storage The Harding Steel (Vehicle Transport System)

More information

QUICK REFERENCE. (Psi) RANGE (PSI)

QUICK REFERENCE. (Psi) RANGE (PSI) @ & SYMBOL @ BOSCH ~Engineering Data VARABLE VOLUME VANE PUMPS MODEL SV-40 MODEL TV-40 FLANGE MOUNTED QUCK REFERENCE CHART MODEL SV-40 TV-40 GPM @ 100 Psl 31 @ 1800 RPM 23@ 1200 RPM PRESSURE THEORETCAL

More information

Product Information. Universal intermediate jaw UZB

Product Information. Universal intermediate jaw UZB Product Informaton UZB UZB Flexble. Precse. Stable. UZB unversal ntermedate jaw The unversal ntermedate jaw allows fast tool-free and relable pluggng and shftng of top jaws at the grpper. Feld of applcaton

More information

LIST PRICES WAC AIR CURTAINS

LIST PRICES WAC AIR CURTAINS PRICE SHEET PSWAC-2 EFFECTIVE: March 1, 2011 SUPERSEDES: PSWAC-1 LIST PRICES WAC AIR CURTAINS 4830 TRANSPORT DRIVE, DALLAS, TX 75247 PHONE: 214-638-6010 FAX: 214-905-0806 WAC AIR CURTAINS Basic Unit ITEM

More information

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN

More information

AIR CURTAINS AIR CHAMBER DESIGN

AIR CURTAINS AIR CHAMBER DESIGN AIR CURTAINS AIR CHAMBER DESIGN Pittsburgh, PA Akron, OH Atlanta, GA Los Angeles, CA INDEX How an Air Curtain Works...3 Making an Air Curtain...3 Choosing The Right Air Curtain...4-5 Energy Saving & Return

More information

8500-Series Indirect-Fired Heating, Cooling and Pressurization Systems Dimension and Selection Guide 1.800.536.3461 www.rapidengineering.com GAS/OIL HEATING ONLY RAPID 8500-35 through 8500-125 Upright

More information

Models. Save This Manual For Future Reference. International Comfort Products Corporation (USA) Lewisburg, TN USA LP1 5/16/

Models. Save This Manual For Future Reference. International Comfort Products Corporation (USA) Lewisburg, TN USA LP1 5/16/ Models NTC7050BFG / GNL050NG NTC7075BFG / GNL075NG NTC700BHG / GNL00N6G NTC75BKG / GNL5N0G NDC7050BFG / GDL050NG NDC7075BFG / GDL075NG NDC700BHG / GDL00N6G NDC75BKG / GDL5N0G Manufactured by: International

More information

Product Information. Universal swivel vane RM-W

Product Information. Universal swivel vane RM-W Product Informaton RM-W RM-W Modular. Compact. Flexble. RM-W swvel vane wth hgh torque for fast swvelng tasks Feld of applcaton To be used n clean to slghtly drty envronments such as assembly or packagng

More information

Product Information. Universal rotary unit ERS

Product Information. Universal rotary unit ERS Product Informaton Compact. Flexble. Fast. Electrcal rotary unt wth torque motor and angle of rotaton > 360 as well as the pneumatc holdng brake and rotary feed-through optons, and f desred ncreased protecton

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

INDIRECT FIRED FURNACE PARTS

INDIRECT FIRED FURNACE PARTS INDIRECT FIRED FURNACE PARTS 986964 Power Venter (Combustion Blower) Assembly ** S **Includes: Fan, Motor, Housing, etc. (Fasco) 986365 Igniter S 986725 Flame Sensor S 986982 H.S.I. Module 50E47-XXX w/

More information

Parts List, Charging Chart, Tech Labels, Wiring Diagrams

Parts List, Charging Chart, Tech Labels, Wiring Diagrams Parts List, Charging Chart, Tech Labels, Wiring Diagrams PHT324 PHT360 Single Phase PACKAGE HEAT PUMP UNITS TABLE OF CONTENTS PARTS LIST 2 4 PARTS DRAWING 5 7 CHARGING CHARTS 8 9 TECH LABELS PHT324 10

More information

AF90. AF90 Gas Furnace High Efficiency. Features

AF90.   AF90 Gas Furnace High Efficiency. Features AF90 AF90 Gas Furnace High Efficiency Features Up to 92.1% AFUE Heating size range 50,000 125,000 BTUH 1-1/2 5 tons cooling capacity supported Twenty-year limited warranty on heat exchanger Five-year warranty

More information

Product Information. Miniature swivel Head SKE

Product Information. Miniature swivel Head SKE Product Informaton SKE SKE Compact. Fast. Productve. SKE mnature swvel head 90 swvel head wth sngle pston drve Feld of applcaton For use n clean envronments such as assembly or packagng zones and for lght

More information

Busway Power Distribution

Busway Power Distribution Buswa Power Dstrbuton BD Plug-In ( - -1 Ampere) SELECTION -1 Amperes Cable Tap Box End Closure Hangers End Prces Center Alumnum 3 Phase, 3 Wre EBA302 EBA304 EBA306 EBA308 EBA310 EBA3 1190. 1430. 2110.

More information

UNIBOX Series. Enclosures and wiring accessories IP40 - IP55

UNIBOX Series. Enclosures and wiring accessories IP40 - IP55 Enclosures and wrng accessores IP - IP55 ENCLOSURES AND WIRING ACCESSORIES IP - IP55 GENERAL DESCRIPTION enclosures are desgned to accomodate EVOLUTION Seres accessores and, wth specfc bearng adaptors,

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities 3-35 kw 10,200-119,420 Btuh 208 to 600 Volts 1 or 3 Phase Meets NEC, OSHA and UL Requirements ATEX and GOST Models Available Refer to WR-80EP in the Controls section. F-4 Description Type is designed to

More information

LOW HEIGHT UNIT COOLER

LOW HEIGHT UNIT COOLER Publication No. RU-CTA-0818A Replaces RU-CTA-0712A Ceiling-Temp LOW HEIGHT UNIT COOLER Small to Medium Walk-Ins Cooler and Freezer Applications Air Defrost,00 to 27,00 BTUH Electric Defrost 5,00 to 27,00

More information

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h GPG15 Series Single-Phase, Self-Contained Cooling Capacity: 23,200 56,500 BTU/h Heating Capacity: 69,000 138,000 BTU/h Standard Features High-efficiency compressor Durable, corrosion-resistant T-140 aluminized

More information

ELECTRICAL INDUSTRY CERTIFICATIONS ASSOCIATION

ELECTRICAL INDUSTRY CERTIFICATIONS ASSOCIATION Ef ELECTRCAL NDUSTRY CERTFCATONS ASSOCATON CHARTS Cranes -Terex 347 -National 99 -Broderson C-2 ECA Testing Purposes Only These Range Diagrams and Capacity Charts are not to be used for lifting operations.

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

GSC13 Split System Air Conditioner

GSC13 Split System Air Conditioner Split System Air Conditioner 13 SEER / R-22 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 AHRI Ratings... 18 Wiring Diagram... 19 Dimensions... 20 Accessories...

More information

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information

Stromag. Electromagnetic Fail Safe Brakes Series NFA/NFF. Versions: Basic & Dockside Cranes. Stromag Limited

Stromag. Electromagnetic Fail Safe Brakes Series NFA/NFF. Versions: Basic & Dockside Cranes. Stromag Limited Stromag Electromagnetc Fal Safe Brakes Seres NFA/NFF Versons: Basc & Docksde Cranes Stromag Lmted 29 Wellngborough Road,Rushden Northamptonshre NN10 9YE Unted Kngdom Tel. 01933 350407 Fax. 01933 358692

More information

V High Efficiency Series

V High Efficiency Series UNIT DISCONNECT(S) BEHIND THIS PANAL Commercial HVAC V High Efficiency Series Wallmount Air Conditioners PERFORMANCE: Efficiency rating of 9.0/9.5 EER Electric heat available from 5 kw to 18 kw Designed

More information

1 Air Operated Diaphragm Pump

1 Air Operated Diaphragm Pump Air Operated Diaphragm Pump Model SP00-0X-XX-XXX-X : Ratio (Non-metallic ) nstallation and Operation Manual Read this manual carefully and completely PROR to installing, operating, or servicing this equipment.

More information

FLORE2STONE. A Spec Above.: ---- ~~~~ Just add water. r =! I_1-_,,,, i , I 0 ~..M..,. ' /FLO BuyLine I I 1 Pr.

FLORE2STONE. A Spec Above.: ---- ~~~~ Just add water. r =! I_1-_,,,, i , I 0 ~..M..,. ' /FLO BuyLine I I 1 Pr. 22 40 00/FLO BuyLne 5500.! ' 4,, -~ * FLORE2STONE Spec bove.: Just add water. X.K ', \ \t D! ---- ~~~~ 1 Pr. r =! 4 P _ a.. ) _1-_,,,, 1Y /, ^'l ~..M..,. ' L 1 L.., f t 9 w,....-.......... -.* 0 6-- '%

More information

BHH Product Specifications

BHH Product Specifications BHH Product Specifications HORIZONTAL BELT DRIVE DIRECT EXPANSION BLOWER COIL UNITS ALL S 3, 4, and 5 Ton 208/230 3 60 and 460 3 60 supply voltage Units are ETL listed to U.S. and Canadian safety standards

More information

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

Loadable. Flexible. Robust. Universal Rotary Unit PR

Loadable. Flexible. Robust. Universal Rotary Unit PR PR Electrcal Rotary Unts Unversal Rotary Unt Loadable. Flexble. Robust. Unversal Rotary Unt PR Servo-electrc rotary unt wth angle > 360, precson gear and ntegrated electroncs Feld of Applcaton All-purpose,

More information

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

HYDRONIC HEATING EQUIPMENT Application Manual

HYDRONIC HEATING EQUIPMENT Application Manual HCV-1 HYDRONC HEATNG EQUPMENT Application Manual HORZONTAL AND VERTCAL STEAM/HOT WATER UNT HEATERS Contents PAGE APPLCATON OF UNT HEATERS 2 HORZONTAL UNT HEATERS 3 Steam Performance Data 4 Steam Calculation

More information

Pad-Mounted. Transformers

Pad-Mounted. Transformers June 00 Sheet 0.0- Pad-Mounted Transformers Contents General Descrpton............................................0- Introducton................................................0- Applcaton.................................................0-

More information

13 SEER Light Commercial 3 Phase

13 SEER Light Commercial 3 Phase 13 SEER Light Commercial 3 Phase Packaged Gas / Electric RGE13 Features and Benefits Form No. AC-RGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air

More information

IPV High-pressure Internal Gear Pumps Technical Data Sheet

IPV High-pressure Internal Gear Pumps Technical Data Sheet IV Hgh-pressure Internal ear umps Techncal Data Sheet Functon 1 7 5 9 2 10 8 2 1 9 4a 4b 3 1 non shaft 2 Internal gear 3 Fller pn 4a Fller segment carrer 4b Fller sealng segment 5 Axal dsc Axal pressure

More information

Enclosure Height (inches) Ship Wt. Lb/Std. Pkg. of 1. List Price $

Enclosure Height (inches) Ship Wt. Lb/Std. Pkg. of 1. List Price $ EQ Load Centers Man Breaker wth Copper Bus,OOOA IR I Features Copper bus load centers are recommended for those applcatons where the envronment ma be severe, (.e. farm and coastal areas) or where a premum

More information

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.

More information

Warm. Air Turnover Systems. Applied Air. Keeps You. Technical Guide for: IFP IFS CAT IFA IFJ TGATS-4. Standard Gas Heat Air Turnover

Warm. Air Turnover Systems. Applied Air. Keeps You. Technical Guide for: IFP IFS CAT IFA IFJ TGATS-4. Standard Gas Heat Air Turnover TGATS-4 Air Turnover Systems Technical Guide for: IFP IFS CAT IFA IFJ Standard Gas Heat Air Turnover Non Gas Heat Slave Unit Standard Cooling Only Air Turnover with Prop Fans Standard Cooling Coil Plus

More information

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF APD14 Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 6 Expanded Heating Data... 20 Airflow Data... 22 Dimensions...

More information

SECTION Drive Belts, Accessory

SECTION Drive Belts, Accessory 03-05- 1 Drive Belts. Accessorv 03-05- 1 SECTON 03-05 Drive Belts, Accessory SUBJECT PAGE SUBJECT PAGE ADJUSTMENTS REMOVAL AND NSTALLATON Generator/Water Pump Drive Belt Drive Belt, Generator... 03-05-3

More information

CONSTRUCTION SPECIFICATION FOR WATERMAIN AND WATER SERVICE TRACER WIRE INDEX. SUBMISSION AND DESIGN REQUIREMENTS Not Used...2

CONSTRUCTION SPECIFICATION FOR WATERMAIN AND WATER SERVICE TRACER WIRE INDEX. SUBMISSION AND DESIGN REQUIREMENTS Not Used...2 CITY OF TORONTO TORONTO WATER STANDARD CONSTRUCTION SPECIFICATIONS TS 7.40 February 2006 TS 7.40.01 CONSTRUCTION SPECIFICATION FOR WATERMAIN AND WATER SERVICE TRACER WIRE INDEX GENERAL...2 TS 7.40.01.01

More information

600PR SERIES ELECTRONIC IRRIGATION CONTROLLER

600PR SERIES ELECTRONIC IRRIGATION CONTROLLER 6PR SERES ELECTRONC RRGATON CONTROLLER NSTALLATON AND OPERATNG GUDE FOR ALL 64,66,68,612 MODELS ZONE CONTROL: Turns sprinkler valves on and off automatically in sequence, or individually. MULTPLE PROGRAMMNG:

More information

Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP)

Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP) Mark: ASP 1 Model: ASP - 52.00 - S ASP Air Curtain Supply (ASP) Quantity Model Length (in.) Width (in.) Height (in.) Volume (CFM) SP (in. wg) 1 Air Curtain Supply (ASP) 52 14 10 740 0.13 Supply Collar

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMINAL TONS, 1 PH)

LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMINAL TONS, 1 PH) T R P T O N G 259800-YTG-B-0607 SPLT-SYSTEM AR CONDTONERS 13 SEER AY012MA THRU 030 (1 THRU 2.5 NOMNAL TONS, 1 PH) U R A C T MA N U F R E C E UN R T C ER T A R A RY F F E D E Q U C A T T S A T ON O M E

More information

CHNC m CHNCmSP CNC Chucker and Bar Machines

CHNC m CHNCmSP CNC Chucker and Bar Machines HARDNG( ------=-'"' PARTS LST TP1410 CHNC m CHNCmSP CNC Chucker and Bar Machines EQUPPED WTH THE GEFANUC18TCONTROL Manual No. PL-61 A Part No. PLA-0009500-0061 Litho in U.S.A. May, 1996 TO ORDER REPLACEMENT

More information

Operating Instructions Pneumatic drives

Operating Instructions Pneumatic drives Operatng Instructons Pneumatc drves Pneumatc drves Equpment characterstcs Poston ndcator (detachable)! Settng screw for pvot angle 1 4 5 Ar nterface accordng to VDI / VDE 3845 (Namur) Advantages of the

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Product Information. Long-stroke gripper PZH-plus

Product Information. Long-stroke gripper PZH-plus Product Informaton Long-stroke grpper PZH-plus PZH-plus Long-stroke grpper Flexble. Robust. Flat. PZH-plus unversal grpper Unversal grpper wth long travel and hgh maxmum moment due to mult-tooth gudance

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems Medium Pressure Axial Fans Model TBI-FS Levels 3, 4 & 5 with Fabricated Steel Propeller Belt Drive Inline or Roof Mounted Upblast Clean Air or Fume Exhaust High Temperature Process Exhaust Emergency Smoke

More information

80 TDD2B060,080, C100,D120A9V

80 TDD2B060,080, C100,D120A9V Downflow/Horizontal Right or Downflow/Horizontal Left 2-Stage, Variable Speed Gas-Fired Furnace XV 80 TDD2B060,080, C100,D120A9V Two-Stage Fan Assisted Combustion System TDD-D-1 PUB. NO. 22-1673-07 General

More information

Product Information. Compact linear module ELP

Product Information. Compact linear module ELP Product Informaton ELP ELP Easy. Fast. Relable. ELP compact lnear module Electrc lnear module wth drect drve and ntegrated controller, scope-free guded usng pre-loaded roller gude Feld of applcaton For

More information

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h Cooling Capacity: 18,000-60,000 BTU/h Split System Heat Pump 13 SEER / R-410A Heating Capacity: 18,000-59,000 BTU/h Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

CHASSIS GROUP OLDSMOBILE ILLUSTRATION INDEX

CHASSIS GROUP OLDSMOBILE ILLUSTRATION INDEX TMOBIL 1ltM0514 CHASSIS GROUP 8.000 OLDSMOBILE ILLUSTRATION INDEX TITLE PAGE TITLE PAGE 1968 Hood Panels, Grilles, Moulding & Attaching Parts 1969 Hood Panels, Grilles, Moulding & Attaching Parts 1970

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

XV 80 TDD2B060,080, C100,D120A9V

XV 80 TDD2B060,080, C100,D120A9V Downflow/Horizontal Right or Left 2-Stage Variable Speed Gas-Fired Furnace XV 80 TDD2B060,080, C100,D120A9V Two-Stage Fan Assisted Combustion System PUB. NO. 22-1673-10 General Features NATURAL GAS MODELS

More information

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-1 0,000 feet KV

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana Indoor-Outdoor Altitude 0-1 0,000 feet KV December 1975 New nformation and Supersedes 38-132 F WE A, Pages 1-, dated May 1975, and DS 38-122, pages 1-2, dated December, 1973 E, D, C/1981/DB Dimensions, Weights and Creep These notes apply to all

More information

80% Oil Furnace RLBF(R)

80% Oil Furnace RLBF(R) 80% Oil Furnace Basement-Direct & Belt Drive RLBF(R) FEATURES AND BENEFITS Heavy-duty 14 gauge steel heat exchanger with a long lasting ceramic fiber combustion chamber Easy access large diameter clean

More information

ICEMINI & Vertical MTI Units

ICEMINI & Vertical MTI Units ICEMINI & Vertical MTI Units ICEMINI Units......K-1 ICEMINI-8MPN (Dimension Information)....... K-2 ICEMINI-8MPN (Horizontal Small)....... K-3 ICEMINI-8MPN (Vertical Small)........ K-4 ICEMINI-8MPN (Vertical

More information

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Product Data. that this product meets the S 95% AFUE S Two -stage operation DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information