TURNING AIR INTO SOLUTIONS. PROPELLER WALL FANS WPD WPB

Size: px
Start display at page:

Download "TURNING AIR INTO SOLUTIONS. PROPELLER WALL FANS WPD WPB"

Transcription

1 TURNING AIR INTO SOLUTIONS. PROPLLR WALL S WPD WPB CATALOG 48 March 7

2 PROPLLR WALL S Overview WPB WPD Twin City Fan & Blower Model WPD Medium Duty and Model WPB Light and Medium Duty Propeller Wall Fans are specifically designed for cost effective, generalpurpose ventilation. All models are available in either exhaust or supply configurations. The steel panel design is available with cast aluminum or fabricated steel propellers to meet specific application requirements. Regardless of the application, the WPD and WPB Series offers a high quality, cost competitive propeller fan solution. Model WPD with "" Series Propeller Typical Applications Include Warehouse Ventilation, Restroom xhaust, levator Shaft, Stairwell xhaust, Attic xhaust, Data Center Ventilation, Gymnasium Ventilation, Filtered Supply, Garage xhaust, General HVAC, Farm xhaust, Foundry Ventilation, Factory Ventilation, Greenhouse Ventilation Configurations Available in Both Direct and Belt Driven Configurations Propeller Types "L" and "L2" Propellers; "B" and "" Die Propellers; "C" Propellers; "Z" Propellers Certifications AMCA Sound/Air and FG, UL 705 Listed for lectrical Model WPB with "L" Series Propeller Models WPD and WPB are UL/cUL 705 listed for electrical, File No FS0 For complete product performance, drawings, and available accessories, Download Fan Selector at tcf.com. Twin City Fan & Blower, a Twin City Fan Company certifies that the WPD and WPB Wall Propeller Fans shown herein are licensed to bear the AMCA Seal. The Ratings shown are based on tests and procedures performed in accordance with AMCA Publication 2 and AMCA Publication and comply with the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air and sound performance for Model WPD Sizes 44, 48, 4B05, 64, 68, 6B05, 84, 88 and 8B05 on page and Model WPB Sizes 2L, 2L2, 24, 28, 2B05 and 24L on pages 4-5. The AMCA Certified Ratings Seal applies to the Fan fficiency Grade for Model WPD Sizes 2B05, 24, 28, 24B05, 244, 248, 24Z5, 0B05, 04, 08, 0Z5, 6B6, 64, 68, 6Z5, 42B04, 424, 428, 42Z5, 48B04, 484, 488 and 48Z5 on pages - and Model WPB Sizes 2L2, 2B05, 24, 24L2, 24B05, 244, 248, 24Z5, 0L, 0L2, 0B05, 04, 08, 0Z5, 6L, 6L2, 6B6, 64, 68, 6Z5, 42L, 42L2, 42B04, 424, 428, 42Z5, 48L, 48L2, 48B04, 484, 488, 48Z5, 54L, 54L2, 54B406, 54C, 54C6, 54Z5, 60L, 60L2, 60C, 60C6 and 60Z5 on pages TWIN CITY - CATALOG 48

3 PROPLLR WALL S Overview WPB WPD Construction Features aluminum or fabricated steel propellers. panel with deep formed inlet venturi which distributes air velocity uniformly. Pre-punched mounting holes for ease of installation. Motor supports are constructed of heavy-gauge galvanized steel. Fans designed for exhaust and supply service are provided with motor and drive located on the interior side of the building. Pre-engineered accessories to accommodate any installation. Dynamically balanced propellers for quiet, vibration-free operation. Designed for continuous duty. iron pillow block bearings selected for L50 average life of 0,000 hours at maximum cataloged operating speeds. WPB 2" to 60" wheel diameters Airflow to 62,800 CFM Static pressure to " w.g. WPD 4" to 48" wheel diameters Airflow to 5,00 CFM Static pressure to " w.g. xploded View Model WPD, Arr. 4

4 PROPLLR WALL S SIZ DIRCT DRIV BLT DRIVN 4 B, 6 B, 8 B, 2 B, L, L2, B, 24 B,, Z L, L2, B,, Z 0 B,, Z L, L2, B,, Z 6 B,, Z L, L2, B,, Z 42 B,, Z L, L2, B,, Z 48 B,, Z L, L2, B,, Z 54 L, L2, B, C, Z 60 L, L2, C, Z Propellers WPB WPD WPD and WPB propeller fans are available with either fixed pitch fabricated steel (sizes 2 through 60) or adjustable pitch cast aluminum propellers (sizes 4 through 60). ach propeller type is designed for a wide variety of commercial market applications with static pressure capabilities from 0" to ". Regardless of the application requirement, WPD and WPB propellers offer the right choice. Propeller Availability L & L2 Propellers The L and L2 series features fixed pitch, fabricated steel, 5-bladed propellers. Galvanized steel propeller blades are riveted to galvanized steel hubs. Available in 8 sizes from 2 to 60 diameters in either standard L construction or reinforced L2 construction. B Die Propellers The B series features a die cast aluminum propeller available in 4, 5 and 6 blade designs. Blade angles are factory set and mounted in a die cast aluminum hub. B propellers are available in 4" through 54" diameters. Die Propellers The series features a die cast aluminum propeller available in 4 and 8 blade designs. Blade angles are factory set and mounted in a die cast aluminum hub. propellers are available in 4" through 48" diameters. C Propellers The C series is a cast aluminum propeller available in 4 and 6 blade designs, and is available in 54" and 60" diameters only. Blade angles are factory set and mounted in a cast aluminum hub. Z Propeller The Z series features a fixed pitch, fabricated steel, 5-bladed propeller. blades are continuously welded to a heavy gauge hub at the customer s selected blade angle. Z propellers are available in 24" through 60" diameters. 4 TWIN CITY - CATALOG 48

5 PROPLLR WALL S Pressure Drops Supply & xhaust supports by others XHAUST in Wall Box with Backdraft Damper & Weatherhood supports by others SUPPLY in Wall Box with Backdraft Damper & Weatherhood SIZ CFM PRSS. DROP (IN. W.G.) XHAUST SUPPLY SIZ CFM PRSS. DROP (IN. W.G.) XHAUST SUPPLY SIZ 54 PRSS. DROP CFM (IN. W.G.) XHAUST SUPPLY

6 OPTIONS/ACCSSORIS Airflow Removable Screen Standard component of wall box and motor side guard. Screen is available with bolted removable or hinged construction. Allows for access to motor, bearings and drive components. Wall Box is used to mount the fan and accessories cleanly into a wall, and provides the strongest and safest way to mount wall fans. Wall boxes are constructed of 6-gauge galvanized steel and are provided with heavy-gauge mounting flanges with prepunched mounting holes for ease of installation. Available fully assembled or as a kit (field assembly required) to reduce shipping costs. Wall supports are provided by others. xtended Lube Lines with grease fittings are extended to the outside of the fan housing. Birdscreen protects the fan's internal components from entry of birds. 5 6 Filter Box For applications requiring filtered air, filter boxes are available with wall box or wall collar and fan in supply configuration. Filter box contains 2" thick aluminum washable filters and access panels as standard. Disposable filters and " options are also available upon request. Contact factory for more information. Weatherhood keeps snow and rain from entering the building and to prevent wind from altering the performance of the fan and backdraft damper. The weatherhood is designed to fit over the backdraft damper and can be installed to a wall collar via the mounting flanges and prepunched mounting holes. Weatherhoods are constructed of G90 galvanized steel and are standard with a removable galvanized steel, wire mesh, bird screen. Available fully assembled or as a kit (field assembly required) to reduce shipping costs. Weatherhoods are not weather tight when used with supply fans. 6 TWIN CITY - CATALOG 48

7 OPTIONS/ACCSSORIS Airflow OSHA Motor Side Guard with Removable Screen meets OSHA standards by completely enclosing the motor and drive components. Motor side guards are constructed of galvanized steel side sheets and a removable wire mesh screen. Prepunched mounting holes allow for easy installation to the fan. Can be used with or without a wall collar. NMA 4 Disconnect Switch provides positive electrical shutoff when fan cleaning or maintenance of fan and is water and dust tight. Switch is available shipped loose for field mounting and wiring or factory mounted and wired. See page 8 for other available disconnect switches. Single Point Wiring Available with factory assembled motor side guard or wall box, wired disconnect switch and motorized backdraft damper. Single point wiring option provides a single location for making connections to the damper actuator and disconnect switch. Wall Collars are an economical alternative to the wall box. Wall collars are constructed of 6-gauge galvanized steel. Heavy-gauge mounting flanges with prepunched mounting holes are provided for ease of installation. Available fully assembled or as a kit (field assembly required) to reduce shipping costs. If motor side of fan is to be enclosed, add OSHA motor side guard. Wall supports by others. 5 6 Backdraft Dampers are used to keep the elements and unwanted air out of the building when the fan is not in use. They are constructed to easily fasten to the wall box or wall collar so that the weatherhood or damper guard can easily fit over it. The standard damper frame is constructed of.062 extruded aluminum and the blades are constructed of 26-gauge mill finished aluminum. The leading edge of each damper blade is flanged with a vinyl seal for effective weather protection and quiet closing. Heavy duty/high velocity dampers are provided when the fan is selected at higher air volumes (see velocity table on page ). Frame and blades are.080 extruded aluminum. The blades freely pivot open or close on stainless steel pivot pins on both types. Motorized options are available. See page for additional information on backdraft damper limits. Damper Guard protects the backdraft damper when a weatherhood is not used. It is constructed of 8-gauge G90 galvanized steel side sheets and a galvanized steel screen. The screening complies with OSHA standards and will keep birds out of the fan and building. Mounting flanges and prepunched mounting holes are provided for ease of installation. 7

8 DISCONNCT SWITCHS Disconnect switches provide positive electrical shutoff during fan cleaning or maintenance. NMA Disconnect Switch (Standard) A NMA disconnect switch is available shipped loose for field mounting and wiring or factory mounted and wired with ODP or TFC motors. NMA Disconnect Switch NMA R Disconnect Switch A NMA R, rain proof, disconnect is available shipped loose for field mounting and wiring or factory mounted and wired externally. NMA 4 Disconnect Switch A NMA 4, water and dust tight, disconnect is available shipped loose for field mounting and wiring or factory mounted and wired externally. NMA R Disconnect Switch NMA 7/9 Disconnect Switch A NMA 7/9 disconnect switch is recommended on fans with explosion proof motors. The NMA 7/9 switch is designed for use with fans operating in hazardous environments. Available shipped loose for field mounting and wiring. (Not shown.) NMA 4 Disconnect Switch 8 TWIN CITY - CATALOG 48

9 MODL NOMNCLATUR WPB B Model WPD = Wall Propeller Fan, Direct Drive WPB = Wall Propeller Fan, Belt Driven = xhaust, S = Supply Fan Size Propeller Type L & L2 = Level & Level 2,, Fixed Pitch (5-Bladed) B =, Adjustable Pitch (4, 5, and 6-Bladed) =, Adjustable Pitch (4 and 8-Bladed) C =, Adjustable Pitch (4 and 6-Bladed) Z =, Fixed Pitch (5-Bladed) Hub Designation (B Propellers Only) No. of Blades Propeller Blade Angle (B, C,, and Z Propellers Only) TCF MODL COMPARISON Twin City Fan & Blower offers a full line of propeller fans available in both direct drive and belt driven. ach model and propeller type has been designed for a wide variety of commercial market applications. No matter what the requirements are, Twin City Fan & Blower has the propeller fan to suit the application. LVL 4 LVL 2 PROPLLR CONSTRUCTION Blades Riveted to Hubs Blades and Hubs MODL SIZ RANG PRFORMANC RANG CFM STATIC PRSSUR CAPABILITY PRFORMANC DATA LOCATION TCP 8-24 to 7, Up to in. w.g. Catalog to 5,50 WPD Blades and Hubs 24-48,00 to 2,0 Blades and Hubs PROPLLR CONSTRUCTION Galvanized Blades Riveted to Galvanized Hubs Reinforced Galvanized Blades Riveted to Galvanized Hubs Blades and Hubs Direct Drive TCWP to 9,980 TCWPX 24-60,640 to 72,000 MODL SIZ RANG Belt Driven PRFORMANC RANG CFM Up to.00 in. w.g. Pages - Up to.50 in. w.g. STATIC PRSSUR CAPABILITY Catalog AX500 PRFORMANC DATA LOCATION WPB L ,970 to 5,00 Up to 0.75 in. w.g. Pages 4-22 WPB L2 2-60,450 to 47,600 Up to 0.75 in. w.g. Pages ,0 to 56,700 Pages 4-22 WPB L Up to.00 in. w.g. Blades and Hubs 24-60,00 to 62,800 Pages Blades and Hubs TCWP 24-48,600 to 8,000 TCWPX ,000 to 75,000 Up to.50 in. w.g. Catalog AX

10 MOUNTING ARRANGMNTS MOUNTING FLANG MOUNTING FLANG Flush with Outside Wall RMOVABL GUARD SCRN AIR FLOW SUPPORTS (BY OTHRS) BACKDRAFT DAMPR xhaust WATHRHOOD WITH SCRN RMOVABL GUARD SCRN AIR FLOW SUPPORTS (BY OTHRS) BACKDRAFT DAMPR Supply WATHRHOOD WITH SCRN MOUNTING FLANG MOUNTING FLANG BACKDRAFT DAMPR BACKDRAFT DAMPR Middle of Wall RMOVABL GUARD SCRN AIR FLOW xhaust WATHRHOOD WITH SCRN RMOVABL GUARD SCRN AIR FLOW Supply WATHRHOOD WITH SCRN SUPPORTS (BY OTHRS) SUPPORTS (BY OTHRS) MOUNTING FLANG MOUNTING FLANG Flush with Interior Wall RMOVABL GUARD SCRN AIR FLOW SUPPORTS (BY OTHRS) BACKDRAFT DAMPR xhaust WATHRHOOD WITH SCRN RMOVABL GUARD SCRN AIR FLOW SUPPORTS (BY OTHRS) BACKDRAFT DAMPR Supply WATHRHOOD WITH SCRN Mounting without Accessories AIR FLOW SPACR (BY OTHRS) MIN BACKDRAFT DAMPR SIZ MIN TO ACHIV TH MINIMUM DIMNSION, THIS INSTALLATION RQUIRS A SPACR (BY OTHRS) BTWN TH AND TH WALL. IF TH WALL IS QUAL TO OR GRATR THAN TH MINIMUM DIMNSION, TH CAN B MOUNTD DIRCTLY TO TH WALL. Dimensions are in inches. 0 TWIN CITY - CATALOG 48

11 NGINRING DATA Approx. Shipping Weight (LB.) WPD WPB SIZ B 4 8 Z5 L L2 B 4 8 C C6 Z Material Specification SIZ GAUG OF MATRIAL SHAFT SIZ (IN.) PANL DRIV FRAM PROPLLRS HUBS WPB WPB WPB WPD L/L2 B//C/Z WPD L/L2 B//C/Z L/L2 B C Z L/L2 Z L L2 B//C/Z DI DI 4 /4 / CAST /4 /4 CAST ALUM /4 ALUM / /6 / /6 7 / CAST /6 7 / ALUM. 0 /6 7 /6 /2 /6 Outlet Velocities SIZ STANDARD HAVY DUTY DAMPR DAMPR OUTLT VLOCITY MAX. FPM MIN. FPM Backdraft Damper Limits STANDARD DAMPR HAVY DUTY DAMPR SIZ VLOCITY MAX. VLOCITY MAX. CFM MAX. CFM MAX. (FPM) (FPM) Not Required

12 PRFORMANC DATA DIRCT DRIV WPD Sizes 4-2 MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. SIZ PROPLLR BLAD HP RPM 0" SP ANGL GRAD Max RPM B05 = = = 750 Max Motor Frame Size = 56 Outlet Area (ft 2 ) = B / N/A / B B B / N/A 2 / / N/A 24 / Max RPM B05 = = = 750 Max Motor Frame Size = 56 Outlet Area (ft 2 ) = / / N/A / / / N/A 28 / / N/A / Max RPM B05 = = = 750 Max Motor Frame Size = 56 Outlet Area (ft 2 ) =.82 0 / / N/A 25 / / / N/A / / N/A / Max RPM B05 = = = 750 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / / FG / / / / / / NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Performance ratings do not include the effects of appurtenances (accessories).. The sound ratings shown are loudness values in fan sone at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 4. The AMCA Certified Ratings Seal applies to sone ratings only. 2 TWIN CITY - CATALOG 48

13 PRFORMANC DATA DIRCT DRIV WPD Sizes 24-6 MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. SIZ PROPLLR BLAD HP RPM 0" SP ANGL GRAD Max RPM B05 = = = 750 Z5 = 750 Max Motor Frame Size = 84T Outlet Area (ft 2 ) =.2 0 / B / / Z5 B Z5 B6 4 8 Z5 6 / / / / / / / / / Max RPM B05 = 60 4 = 60 8 = 60 Z5 = 60 Max Motor Frame Size = 84T Outlet Area (ft 2 ) = / / / / / / / / / Max RPM B6 = 60 4 = 60 8 = 60 Z5 = 60 Max Motor Frame Size = 25T Outlet Area (ft 2 ) = / / / FG75 FG75 FG75 NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Performance ratings do not include the effects of appurtenances (accessories).. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 4. The AMCA Certified Ratings Seal applies to sone ratings only.

14 PRFORMANC DATA DIRCT DRIV WPD Sizes MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. SIZ PROPLLR BLAD HP RPM 0" SP ANGL GRAD Max RPM B04 = = = 860 Z5 = 860 Max Motor Frame Size = 254T Outlet Area (ft 2 ) = B04 5 / / Z Max RPM B04 = = = 860 Z5 = 860 Max Motor Frame Size = 254T Outlet Area (ft 2 ) = / B FG Z FG75 NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Performance ratings do not include the effects of appurtenances (accessories).. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 4. The AMCA Certified Ratings Seal applies to sone ratings only. 4 TWIN CITY - CATALOG 48

15 PRFORMANC DATA BLT DRIVN WPB Size 2 MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS PROPLLR BLAD HP RPM 0" SP ANGL Level Performance Max RPM L = 085 Max Motor Frame Size = 56 Outlet Area (ft 2 ) = / L / / Level 2 Performance Max RPM L2 = 24 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = L2 / / Level Performance Max RPM B05 = = = 280 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / B05 25 / / / / / / / / / / / FF. GRAD N/A FG60 N/A NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 5. The AMCA Certified Ratings Seal applies to sone ratings only. 5

16 PRFORMANC DATA BLT DRIVN WPB Size 24 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 907 Max Motor Frame Size = 56 Outlet Area (ft 2 ) = / / L /2 / Level 2 Performance Max RPM L2 = 986 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / L2 / Level Performance Max RPM B05 = 90 4 = 90 8 = 75 Z5 = 450 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / B Z5 25 / / / / / / / / / / / FF. GRAD N/A FG6 NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 5. The AMCA Certified Ratings Seal applies to sone ratings only. 6 TWIN CITY - CATALOG 48

17 PRFORMANC DATA BLT DRIVN WPB Size 0 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 696 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / / L / / Level 2 Performance Max RPM L2 = 950 Max Motor Frame Size = 84T Outlet Area (ft 2 ) = / L2 / FF. GRAD NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 5. The AMCA Certified Ratings Seal applies to sone ratings only. 7

18 PRFORMANC DATA BLT DRIVN WPB Size 0 (continued) MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. PROPLLR BLAD HP RPM 0" SP ANGL GRAD Level Performance Max RPM B05 = = = 975 Z5 = 295 Max Motor Frame Size = 84T Outlet Area (ft 2 ) = / / B / / / / / / / / Z5 5 / / NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 5. The AMCA Certified Ratings Seal applies to sone ratings only. 8 TWIN CITY - CATALOG 48

19 WPB Size 6 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 55 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / / L L2 / Level 2 Performance Max RPM L = 69 Max Motor Frame Size = 84T Outlet Area (ft 2 ) = / Level Performance Max RPM B6 = 95 4 = 95 8 = 95 Z5 = 095 Max Motor Frame Size = 84T Outlet Area (ft 2 ) = B6 4 8 Z5 25 / / / / / / / / NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). PRFORMANC DATA BLT DRIVN FF. GRAD 4. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 5. The AMCA Certified Ratings Seal applies to sone ratings only. 9

20 PRFORMANC DATA BLT DRIVN WPB Size 42 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 424 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / / L / Level 2 Performance Max RPM L2 = 72 Max Motor Frame Size = 84T Outlet Area (ft 2 ) = / L Level Performance Max RPM B04 = = = 660 Z5 = 870 Max Motor Frame Size = 25T Outlet Area (ft 2 ) = B Z / / / / FF. GRAD FG75 NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 5. The AMCA Certified Ratings Seal applies to sone ratings only. TWIN CITY - CATALOG 48

21 WPB Size 48 MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. PROPLLR BLAD HP RPM 0" SP ANGL GRAD Level Performance Max RPM L = 55 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / L / Level 2 Performance Max RPM L2 = 608 Max Motor Frame Size = 84T Outlet Area (ft 2 ) = / L Level Performance Max RPM B04 = = = 670 Z5 = 805 Max Motor Frame Size = 25T Outlet Area (ft 2 ) = / B Z5 PRFORMANC DATA BLT DRIVN / / / / / / FG75 NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 5. The AMCA Certified Ratings Seal applies to sone ratings only. 2

22 PRFORMANC DATA BLT DRIVN WPB Size 54 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 4 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / L / Level 2 Performance Max RPM L2 = 508 Max Motor Frame Size = 84T Outlet Area (ft 2 ) = / L Level Performance Max RPM B406 = 985 C = 985 C6 = 795 Z5 = 665 Max Motor Frame Size = 254T Outlet Area (ft 2 ) = / B / / C / / C / / Z / FF. GRAD FG75 FG60 FG6 NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 5. The AMCA Certified Ratings Seal applies to sone ratings only. 22 TWIN CITY - CATALOG 48

23 PRFORMANC DATA BLT DRIVN WPB Size 60 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 00 Max Motor Frame Size = 45T Outlet Area (ft 2 ) = / L L2 / Level 2 Performance Max RPM L2 = 99 Max Motor Frame Size = 25T Outlet Area (ft 2 ) = / Level Performance Max RPM C = 955 C6 = 850 Z5 = 685 Max Motor Frame Size = 256T Outlet Area (ft 2 ) = C / C / / Z / FF. GRAD FG56 FG6 NOTS:. Performance certified is for installation type A: Free inlet, free outlet. 2. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at 5 ft. (.5m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 5. The AMCA Certified Ratings Seal applies to sone ratings only. 2

24 DIMNSIONAL DATA Direct Drive - WPD D MAX.00 B D MAX B.00 C SQ. (OUTSID) A DIA. C SQ. (OUTSID) A DIA. AIR FLOW AIR FLOW.44 X.75 SLOTS.44 X.75 SLOTS xhaust Airflow Supply Airflow SIZ A B C SQ. XHAUST D MAX SUPPLY DAMPR SIZ MAX MOTOR FRAM x x x x 22 45T x 25 84T x 84T x 9 25T x T x 5 254T D480-2A D480-A 24 TWIN CITY - CATALOG 48

25 Belt Driven - WPB DIMNSIONAL DATA D MAX X.75 SLOTS D MAX 2.00 D MAX X X SLOTS.00 SLOTS Supply Airflow A DIA. C SQ. (OUTSID) A DIA. C SQ. (OUTSID) A DIA. C SQ. (OUTSID) BLT DRIVN SIZS 2-60 L AND L2 BLT DRIVN SIZS 2-6 B,, C, Z B BLT DRIVN SIZS B,, C, Z B AIR FLOW D MAX B D MAX B D MAX B X.75 SLOTS X.75 SLOTS X.75 SLOTS xhaust Airflow C SQ. (OUTSID) A DIA. C SQ. (OUTSID) A DIA. C SQ. (OUTSID) A DIA. AIR FLOW 2.00 BLT DRIVN SIZS 2-60 L AND L2 F BLT DRIVN SIZS 2-6 B,, C, Z BLT DRIVN SIZS B,, C, Z WPB Levels & 2 WPB Level Sizes 2-6 WPB Level Sizes SIZ A B C XHAUST D MAX SUPPLY F (XHAUST ONLY) SHAFT SIZ MAX MOTOR FRAM DAMPR SIZ L L2 B,, C, Z L L2 B,, C, Z L, L2 L L2 B,, C, Z L L2 B,, C, Z T 45T 22 x T 45T 25 x T 84T 84T x T 84T 84T 9 x T 84T 25T 45 x T 84T 25T 5 x T 84T 254T 57 x T 25T 256T 6 x 6 D48-2A D48-A 25

26 DIMNSIONAL DATA Wall Box with Removable Screen A SQ. (INSID) C SQ. 6 GA. B SIZ A SQ. B C SQ. MINIMUM WALL OPNING D48-6B Wall Collar A SQ. I.D. C SQ. 6 GA. B SIZ A SQ. B C SQ. MINIMUM WALL OPNING D48-7B Backdraft Damper 5 /8" TYP /2" TYP /2" TYP A SQ. B SQ. I.D. 5 /8" TYP 6.25" RF " S AIRFLOW C OPN POSITION SIZ A SQ. FLANG B SQ. xhaust Damper shown (with front flange). Supply damper has rear flange. C NO. OF PANLS TWIN CITY - CATALOG 48

27 DIMNSIONAL DATA Weatherhood with Bird Screen A SQ. I.D. DTAIL A SCAL : 4 C SQ. D SQ. RAIN LIP 2.88, TYP F, QTY-G- B A SIZ A SQ. B C D STD. XT. STD. XT. GA Standard flange weatherhood shown. D48-9C 0 BIRDSCRN., TYP QTY-- Damper Guard B SQ. (MOUNTING HOLS) 8 GA. A SQ. 8" C SQ. SIZ A SQ. B SQ. C SQ D48-5A OSHA Motor Side Guard A SQ. OUTSID B 8 GA. SIZ A SQ. B D48-0B 27

28 TYPICAL SPCIFICATIONS Model WPD Wall propeller fans shall be Model WPD direct drive as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. PRFORMANC - Fans shall be tested in accordance with AMCA 20 and AMCA 00 test codes for air moving devices and shall be guaranteed by the manufacturer to deliver rated published performance levels. Fans shall be licensed to bear the AMCA certified ratings seal for both sound and air. CONSTRUCTION - Fan panels and motor mount assemblies shall be constructed of heavy gauge steel for durability and appearance. Panels shall have a deep formed inlet venturi and pre-punched holes for easy mounting. PROPLLRS - Propellers shall be constructed of fabricated steel or cast aluminum blades and hubs. Propellers on direct drive units shall be mounted directly on the motor shaft with a taperlock bushing. Propellers on belt driven units shall be welded to the fan shaft or secured with a taperlock bushing. MOTORS - All motors shall be split phase and capacitor start single phase or three phase induction, permanently lubricated, heavy-duty, ball bearing type, closely matched to the fan load and provided at the voltage, phase, hertz, and enclosure as provided on the fan schedule. FINISH AND COATING - Fans shall have galvanized steel or painted steel orifice panels and motor supports. ACCSSORIS - When specified, accessories such as wall boxes, wall collars, OSHA motor side guards, weatherhoods, backdraft dampers, damper guards, and disconnect switches shall be provided by Twin City Fan to maintain one source responsibility. FACTORY RUN TST - All fans prior to shipment shall be completely assembled and test run as a unit at operating speed or maximum RPM allowed for the particular construction type. ach propeller shall be statically and dynamically balanced in accordance with ANSI/AMCA 4-96 Balance Quality and Vibration Levels for Fans to Fan Application Category BV-, Balance Quality Grade G6.. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy shall be available upon request. GUARANT - The manufacturer shall guarantee the workmanship and materials for its WPD wall propeller fans for at least one () year from startup or eighteen (8) months from shipment, whichever occurs first. 28 TWIN CITY - CATALOG 48

29 TYPICAL SPCIFICATIONS Model WPB Wall propeller fans shall be Model WPB belt driven as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. PRFORMANC - Fans shall be tested in accordance with AMCA 20 and AMCA 00 test codes for air moving devices and shall be guaranteed by the manufacturer to deliver rated published performance levels. Fans shall be licensed to bear the AMCA certified ratings seal for both sound and air. CONSTRUCTION - Fan panels and motor mount assemblies shall be constructed of heavy gauge steel for durability and appearance. Panels shall have a deep formed inlet venturi and pre-punched holes for easy mounting. PROPLLRS - Propellers shall be constructed of fabricated steel or cast aluminum blades and hubs. Propellers on direct drive units shall be mounted directly on the motor shaft with a taperlock bushing. Propellers on belt driven units shall be welded to the fan shaft or secured with a taperlock bushing. SHAFTS - Shafts shall be AISI 045 cold rolled steel, accurately turned, ground, polished, and ring gauged for accuracy. Shafts shall be sized for the first critical speed of at least.4 times the maximum speed. BARINGS - Bearings are to be pillow block, heavy-duty, anti-friction, self-aligning, grease lubricated, ball type. ach fan s bearings are sized with a minimum average life, per AFBMA, in excess of 0,000 hours when operating at the maximum RPM of the class. DRIVS - Motor sheaves shall be cast iron, and supplied as variable pitch standard. Drives and belts shall be rated for a minimum of 50% of the required motor HP. MOTORS - All motors shall be split phase and capacitor start single phase or three phase induction, permanently lubricated, heavy-duty, ball bearing type, closely matched to the fan load and provided at the voltage, phase, hertz, and enclosure as provided on the fan schedule. FINISH AND COATING - Fans shall have galvanized steel or painted steel orifice panels and motor supports. ACCSSORIS - When specified, accessories such as wall boxes, wall collars, OSHA motor side guards, weatherhoods, backdraft dampers, damper guards, and disconnect switches shall be provided by Twin City Fan to maintain one source responsibility. FACTORY RUN TST - All fans prior to shipment shall be completely assembled and test run as a unit at operating speed or maximum RPM allowed for the particular construction type. ach propeller shall be statically and dynamically balanced in accordance with ANSI/AMCA 4-96 Balance Quality and Vibration Levels for Fans to Fan Application Category BV-, Balance Quality Grade G6.. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy shall be available upon request. GUARANT - The manufacturer shall guarantee the workmanship and materials for its WPB wall propeller fans for at least one () year from startup or eighteen (8) months from shipment, whichever occurs first. 29

30 INDUSTRIAL & COMMRCIAL S Centrifugal Fans Utility Sets Plenum & Plug Fans Inline Centrifugal Fans Mixed Flow Fans Tubeaxial & Vaneaxial Fans Propeller Wall Fans Propeller Roof Ventilators Centrifugal Roof & Wall xhausters Ceiling Ventilators Gravity Ventilators Duct Blowers Radial Bladed Fans Radial Tip Fans High fficiency Industrial Fans Pressure Blowers Laboratory xhaust Fans Filtered Supply Fans Mancoolers Fiberglass Fans Custom Fans Twin City Fan Companies, Ltd. A Twin City Fan Company TWIN CITY & BLOWR Trenton Lane N Minneapolis, MN Phone: Fax: Twin City Fan Companies, Ltd., Minneapolis, MN. All rights reserved. Catalog illustrations cover the general appearance of Twin City Fan & Blower products at the time of publication and we reserve the right to make changes in design and construction at any time without notice.

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PROPELLER WALL FANS WPD WPB CATALOG 4820 MARCH 2017

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PROPELLER WALL FANS WPD WPB   CATALOG 4820 MARCH 2017 Twin City Fan INDUSTRIAL PROCSS AND COMMRCIAL VNTILATION SYSTMS PROPLLR WALL S WPD WPB CATALOG 48 MARCH 7 PROPLLR WALL S Overview WPB WPD Twin City Fan & Blower Model WPD Medium Duty and Model WPB Light

More information

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED ROOF VENTILATORS LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply) CATALOG 4860 April 17 ROOF VENTILATORS Overview Propeller Roof Ventilators LHB with

More information

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST ROOF VENTILATORS LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat) CATALOG 4870 April 17 ROOF VENTILATORS Overview Propeller Roof

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE BELT AND DIRECT DRIVE MODEL FEATURES Exhaust air up to 78,000 CFM in static pressure applications up to 1/2 w.g. Straight-through air flow design results in maximum exhaust efficiency Belt drives permit

More information

DIrect drive exhaust & supply panel fans

DIrect drive exhaust & supply panel fans Air Moving Solutions. DIrect drive exhaust & supply panel fans MODEL BULLETIN 4800 March 2012 Direct DrivePanel ans Model panel fans are direct drive panel fans designed for low static pressures. They

More information

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP CATALOG 4135 February 2017 PENTHOUSE ROOF VENTILATORS Overview DCLH I BCLH I DCLP I BCLP Model

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

sidewall propeller fans L 1.07 models lc, l2 & l3 january 2007 belt drive - exhaust & supply three levels of construction

sidewall propeller fans L 1.07 models lc, l2 & l3 january 2007 belt drive - exhaust & supply three levels of construction R SOUND and PERFORMANCE MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. Jenco, Div. of Soler & Palau Ventilation Group, certifies that the models shown herein are licensed to bear the AMCA Seal. The

More information

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24 72 Diameter Bulletin PF-1410 July 2003 A Fläkt Woods Company PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003 Fläkt Woods Group Creative Air Fläkt Woods was created by bringing together several of the worlds leading players

More information

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading

More information

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS K Series Direct Drive K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS SPECIFICATIONS Fans shall be direct drive propeller type with integral motorside OSHA style guard. Propeller construction shall be of

More information

K SERIES SIDEWALL PROPELLER FANS

K SERIES SIDEWALL PROPELLER FANS K SERIES S Models LWBK/LMBK and LRBK/LNBK K SERIES S The Carnes Sidewall Propeller Fan series Models LW/LM and LR/LN have been designed for quiet and efficient air flow performance with the lowest possible

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

Propeller Fan BE Series

Propeller Fan BE Series Propeller Fan BE Series ENCLOSED BELT DRIVEN WALL EXHAUST THESE LOW PRESSURE BELT DRIVEN S ARE IDEALLY SUITED FOR VENTILATION OF UNDERGROUND GARAGES OF APARTMENT BUILDINGS, WAREHOUSES, PUBLIC BUILDINGS,

More information

Propeller Upblast Roof Fans

Propeller Upblast Roof Fans Propeller Upblast Roof Fans Models RBU, RBUMO, RDU and RGU Direct Drive, Belt Drive and Gravity April 2010 Propeller Upblast Roof Fans Greenheck upblast propeller fans are designed to discharge contaminants

More information

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS MODEL FEATURES Supply air to over 56,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Filtered models available

More information

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER MODEL CWD MODEL FEATURES Exhaust air up to 3,360 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2

More information

Propeller Hooded Roof Fans

Propeller Hooded Roof Fans Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive

More information

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 March 2018 CEILING & INLINE VENTILATORS Overview T I TL Twin City Fan & Blower s T-Series Ceiling and TL-Series

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD Model Features Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

Propeller Fan BE Series

Propeller Fan BE Series Propeller Fan BE Series ENCLOSED BELT DRIVEN WALL EXHAUST FAN THESE LOW PRESSURE BELT DRIVEN FANS ARE IDEALLY SUITED FOR VENTILATION OF UNDERGROUND GARAGES OF APARTMENT BUILDINGS, WAREHOUSES, PUBLIC BUILDINGS,

More information

TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH

TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH CATALOG 405 February 207 ROOF & WALL EXHAUSTERS Overview Roof & Wall Exhausters Twin

More information

CONSTRUCTION FEATURES AND OPTIONS

CONSTRUCTION FEATURES AND OPTIONS MODEL SQD & esqd MODEL FEATURES Exhaust air up to 2,8 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV CATALOG 600 March 2012 VentilatingSets Models BCV BCVU5 BCVU2 BCVSH BAV FCV Twin City Fan s line of utility ventilating sets is one

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

MODELS LCE/LCS, L2E/L2S, L3E/L3S

MODELS LCE/LCS, L2E/L2S, L3E/L3S LINE OVERVIEW S&P s Belt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With levels of construction, the belt drive models are for

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER MEL TXD MEL FEATURES Exhaust air up to 3,400 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside

More information

VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS

VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS SECTION 11 OPTIONAL ACCESSORIES VXDAF filter sections are insulated and supplied with 1 framed aluminum mesh filter.

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,

More information

Low Silhouette Power Roof Ventilator Propeller

Low Silhouette Power Roof Ventilator Propeller LOW SILHOUETTE Models LT, LG and LF Power Roof Ventilator Propeller Contemporary Styling Carnes line of low silhouette power roof ventilators are ideal for installations requiring high performance and

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0116 January 2016 Centrifugal Spun Aluminum Line Overview

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0317 March 2017 Centrifugal Spun Aluminum Line Overview

More information

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS UPBLAST PROPELLER FANS Model LUBK SECTION 16 MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS Application Model LUBK is a high capacity roof mounted exhauster rated from 3,560 to 42,000 CFM. It

More information

CEILING & INLINE/CABINET VENTILATORS

CEILING & INLINE/CABINET VENTILATORS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 MARCH 2018 CEILING & INLINE VENTILATORS OVERVIEW T I TL T-Series

More information

Axial Propeller Panel Fans, PAF-Series

Axial Propeller Panel Fans, PAF-Series Axial Propeller Panel Fans, PAF-Series TABLE OF CONTENTS 3 Introduction 4 Certifications & Listings 4 Options & Accessories 9 Motor Availability 11 Direct Drive Dimensional & Performance Data 14 Belt Drive

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page SRSH Tamper Proof Downblast Centrifugal Exhaust Ventilators Page Introduction....................................... 2 SRSH-D Specifications and Dimension Data............. 3 SRSH-B Specifications and

More information

UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS

UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH CATALOG 405 APRIL 08 ROOF & WALL EXHAUSTERS

More information

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall

More information

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit

More information

MODEL COMPARISON MOUNTING ARRANGEMENT OPTIONS

MODEL COMPARISON MOUNTING ARRANGEMENT OPTIONS LINE OVERVIEW S&P s Direct Drive Sidewall Propeller Fan line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models

More information

LOW PRESSURE MIXED FLOW FANS

LOW PRESSURE MIXED FLOW FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS LOW PRESSURE MIXED FLOW FANS QCLB QCLBR QCLBSH CATALOG 1070 JANUARY 2017 MIXED FLOW FANS Models QCLB QCLBR QCLBSH QCLB (Horizontal) Benefits

More information

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS LINE OVERVIEW S&P s Direct Drive Sidewall Propeller Fan line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

ceiling & inline/cabinet ventilators

ceiling & inline/cabinet ventilators Air Moving Solutions. ceiling & inline/cabinet ventilators T-Series ( T TL ) CATALOG 4600 March 2012 Ceiling&InlineVentilators T-Series T TL Twin City Fan & Blower s T Series Ceiling and TL Series Inline/Cabinet

More information

Twin City Fan & Blower

Twin City Fan & Blower BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial

More information

Your Clean Air Source!

Your Clean Air Source! Direct Drive Your Clean Air Source! HIGH QUALITY... HIGH FFICINCY... VRSATILITY stablished in 1893, Peerless Blowers has a well established record of manufacturing a complete line of heavyduty industrial

More information

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS BULLETIN 0 January 007 SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS TYPE ACX / ACXD TYPE ATD / ATDR / ATDW / ATDWR TYPE ATB / ATBR / AWX / AWXR Model ACX Model ATB Model ACXD Model ATDR Model AWX Centrifugal

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

Your Clean Air Source!

Your Clean Air Source! Direct Drive Your Clean Air Source! HIGH QUALITY... HIGH FFICINCY... VRSATILITY stablished in 1893, Peerless Blowers has a well established record of manufacturing a complete line of heavyduty industrial

More information

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 52,000 CFM in static pressure applications up to 3/4 w.g. Motor and drives are located outside of the exhaust

More information

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2.

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2. BDU Belt Drive - Centrifugal Up-Blast Fans W HT F Grease Drain B R RO Features & Benefits Complete range of motors available to meet specific application needs Heavy duty construction, durable and weather

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG   CATALOG 4720 MAY 2014 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014 WWW.TCF.COM GRAVITY VENTILATORS Overview Gravity Ventilators Models

More information

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4050 November 2009 DOWNBLAST ROOF EXHAUSTERS TYPE DCRD / BCRD (Spun Aluminum Housing) TYPE BCRD-E (Endurex Polymeric Housing) Downblast Roof Exhausters Twin City Fan & Blower

More information

DOWNBLAST ROOF EXHAUSTERS

DOWNBLAST ROOF EXHAUSTERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS DOWNBLAST ROOF EXHAUSTERS DCRD BCRD BCRD-E (Endurex Polymeric Housing) CATALOG 4050 FEBRUARY 07 DOWNBLAST ROOF EXHAUSTERS Overview DCRD

More information

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS S CSF & LSF Model CSF Hooded Design FEATURES Supply air to over 13,000 CFM in static pressure capabilities to 2 w.g. Heavy-galvanized construction Belt drives permit easy performance adjustments when needed

More information

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories IRECT RIVE TUBEAXIAL FANS Model LIA Model LIA IRECT RIVE TUBEAXIAL FANS SECTION 12 Application Carnes Company tubeaxial fans offer one of the widest ranges of sizes, horsepower and performance in the industry.

More information

EcoWatt Products. Advancing Ventilation

EcoWatt Products. Advancing Ventilation EcoWatt Products Advancing Ventilation EcoWatt-0817 August 2017 What is EcoWatt At S&P we strive to engineer and manufacture the most efficient products in the market. In order to categorize our most energy

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except

More information

Square Inline Fans with Multi-Directional Discharge

Square Inline Fans with Multi-Directional Discharge SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension

More information

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS R MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as

More information

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted The Industrial Choice. Model FSWB Wall Mounted Model FSR Roof Mounted FILTERED AIR SUPPLY FANS Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF CATALOG 664 June 2013 Filtered Air Supply Fans Roof

More information

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 405 April 2009 UPBLAST ROOF, WALL, & KITCHEN EXHAUSTERS TYPE DCRU / DCRUR / DCRW / DCRWR TYPE BCRU / BCRUR / BCRW / BCRWR TYPE BCRUSH (Smoke & Heat) Upblast Roof, Wall,

More information

MODELS LCE/LCS, L2E/L2S, L3E/L3S

MODELS LCE/LCS, L2E/L2S, L3E/L3S ELT DRIVE SIDEWLL PROPELLER FNS LINE OVERVIEW Jenco s elt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 levels of construction,

More information

FKUB Belt Drive - Centrifugal Up-Blast Fans

FKUB Belt Drive - Centrifugal Up-Blast Fans FKUB Belt rive - Centrifugal Up-Blast Fans W HT F Grease rain B R RO C Features & Benefits Complete range of motors available to meet specific application needs Heavy duty construction, durable and weather

More information

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as restrooms,

More information

TUBULAR CENTRIFUGAL INLINE FANS

TUBULAR CENTRIFUGAL INLINE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBULAR CENTRIFUGAL INLINE FANS MODEL TSL CATALOG 1001 APRIL 2014 CENTRIFUGAL INLINE FANS Model TSL The TSL is an inline centrifugal

More information