R-22. ACUM-S + CADX-S Series. Split Air Conditioners. Range 4 TR to 24 TR (14.1 kw to 84.5 kw) Sharjah Economic Excellence Award winner
|
|
- Stuart Floyd
- 6 years ago
- Views:
Transcription
1 R ACUMS CADXS Series Split Air Conditioners Range 4 TR 4 TR (14.1 kw 84.5 kw) facebook.com/skmuae youtube.com/marketingskm Sharjah Economic Excellence Award winner
2 ACUMS CADXS Series R Contents Introduction... Legend... Nomenclature... General Features...3 Component Features...3 Optional Features...4 Specifi cations...5 Legend Capacity Ratings...7 Fan Performance...17 Typical Wiring Diagram...15 Electrical Data...14 Dimensional Data...18 Guide Specifi cations...3 Introduction SKM Air Cooled Split AirConditioners consist of ceiling suspended indoor Fan Coil Unit CADXS and floor mounted outdoor Air Cooled Condensing Unit ACUMS. The following legends are used throughout this manual: AFR... Air Flow Rate BPF... Bypass Facr CFM... Cubic feet per minute Hz... Hertz in.wg... inch water gauge KW... Kilowatts kg... Kilogram lbs... Pounds MBH... BTUH X 1000 Pa... Pascal Ph... Phase PI... Power Input (for compressor) rpm...rotations per minute TR...Tons of refrigeration SKM Split units are available in 18 variations cover the range from TR (14 81 kw) in 50 Hz and from TR (16 9 kw) in 60Hz at nominal ARI conditions, which make them ideally suited for use in apartments, of f ces, shops, schools and the like. SKM split units are suitable operate in a wide range of ambient temperatures from 50 F (10 C) 15 F (51.7 C). Nomenclature ACU M 050 Y S SKM split units are internally wired and all that is required be done on site is ducting, refrigerant piping and power supply which reduces installation work and consequently keeps costs a minimum. Air Cooled Condensing Unit Series Code Model Designation Scroll Compressor Power Supply Code Y: V/3Ph/50Hz P: 440V/3Ph/50Hz R: 380V/3Ph/60Hz E: V/3Ph/60Hz T: 030V/3Ph/60Hz SKM split air conditioner are simply, Comfort Air Conditioner Direct Expansion Cooling Coil C A D X Y S Scroll Compressor You name it...we cool it Model Designation Power Supply Code Y: V/3Ph/50Hz P: 440V/3Ph/50Hz R: 380V/3Ph/60Hz E: V/3Ph/60Hz T: 030V/3Ph/60Hz
3 ACUMS CADXS Series R GENERAL FEATURES SKM split Air Conditioners incorporate many salient features in both the indoor and outdoor units which, gether, provides a heavy duty, robust and long lasting commercial unit meant for high end residential and most commercial applications. The Split Air Conditioners combine high effi ciency components provide an extremely rugged and energy effi cient split system that will provide cooling with higher effi ciency over a long and extended life. What makes SKM split systems yet another model in the p class range of SKM products is the use of : High effi ciency tally sealed hermetic compressors utilising the most current state of the art technology. Totally enclosed, Class F insulated, IP55 protected condenser and evaporar fan mors. Heavy duty condenser and evaporar coils optimised in design for longlife maintenance free operation. Cabinet construction specifi cally for Gulf climates. Electrical panel with many features, as standard. Facry matched performance and reliable output minimise fi eld decisions. Many standard features not included in residential domestic type split systems. SKM quality proven through a Quality Assurance & Quality Control (QA/QC) system that has recieved the ISO9001 stamp of independent verifi cation. COMPONENT FEATURES CADXS FAN COIL UNIT Evaporar The CADXS fan coil unit evaporar is made of HiX seamless copper tubes mechanically expanded in corrugated aluminium fi ns optimise heat transfer from refrigerant air. Filter 1inch (5mm) fi lter section with cleanable media is standard and built in the CADXS fan coil. The fi lter section is designed for easy filter access and removal for maintenance. Filters provide average dust arrestance of 54% as per ASHRAE test # 5.1. ACUMS CONDENSING UNIT Compressor Compressors used in ACUMS Series condensing unit are hermetically sealed, compact scroll as standard. All standard controls and accessories necessary for safe operation were all provided. Compressors are equipped with internal mor protecr, facry installed crank case heater and rubber grommets/vibration isolar for controlling structural vibration and with quiet and eff cient operation. Condenser The condenser coils are manufactured from waffl e louver aluminium cross fins and special HiX seamless copper tubes. The internal surface of the tubes is modified by serration ensure optimum heat transfer. All coils are fully pressure tested against leakage at 450 psig (3100 kpa) by pressurising air in the coils under water. A subcooler section is incorporated in the lower section of the condenser increase system capacity. This additional condenser surface provides more cooling using less energy and at no additional cost. The condenser fans are propeller type, aluminium alloy blades, directly driven by tally enclosed electric mors. The fans are arranged for vertical air flow discharge. The impeller fans are statically and dynamically balanced. The fans are provided with heavy duty acrylic coated guards. The condenser fan mors are tally enclosed air over (TEAO) ClassF insulation, IP55 protection, 6 poles and rated for continuous operation at design conditions. These mors are facry wired unit control panel where the mor contacrs are located control the operation of the mors. Mors conform relevant BS/IEC standards. Coils conform AHRI410. All evaporar coils are leak tested 300 psig (608 kpa) by pressurizing the air in the coils under water. Each evaporar coil is supplied with a facry sized and matched thermostatic expansion valve. The evaporar fan is forward curved double inlet double width, multiblade centrifugal fan driven by Vbelts. For accurate adjustment of air fl ow, the evaporar fan is driven by adjustable variable pitch pulley. Fans are statically and dynamically balanced. The evaporar fan mor is IP55 tally enclosed air cooled, 4 poles, and rated for continuous operation at design conditions. Mors conform relevant BS/IEC standards. 3 AIR CONDITIONING EQUIPMENT
4 ACUMS CADXS Series R Casing/Structure The unit casing used in the SKM split air conditioners is made of zinc coated galvanised steel sheets conforming JISG 330 and ASTM A55 which is phosphatized and baked after an electrostatic powder coat of approximately 60 microns. This fi nish and coating can pass a 1000 hour in 5% salt spray testing at 95 F (35 C) and 95% relative humidity as per ASTM B117. Panels and casing are insulated with 1/ (13.0 mm) thick fibre glass (with BGT coating) thermal and acoustic insulation having density of lb/cubic ft. (3.0 kg/m 3 ) and thermal conductivity of 0.3 BTU. in/ft Fh (0.033 W/m K). Insulation meets the requirement of NFPA 90A and 90B for fi re resistance. Control Panel Outdoor condensing units are provided with a weatherproof control panel enclosure comprising all starting, operating and safety controls. The following are the standard components used in all SKM Split System Air Conditioners. Compressor contacrs. Condenser fan mor contacrs and overload relays. ON/OF control switch. High/Low pressure switch. Antirecycling time delay relay. 4 volt control transformer for remote thermostat connection. Starter for maching CADXS unit with Coil Voltage: 4V. Power and control terminals. Optional Accessories As with all SKM air conditioning units, a wide range of options are available with SKM Split Units on request. Copper Fins [For Outdoor Unit Only ] Pre Coated Aluminum Fins Aeris Coating for Aluminium Fins /Copper Fins. (50mm) Flat Filter Section inch thick fi lter section with washable/aluminium media. (FC) (FAP) (FAA)/(FCA) (FFS) Voltage Moniring Module (VMM) Facry installed provide protection in the event of phase burnout, phase reversal and under voltage on the incoming line voltage. Voltage Moniring Module (DVM) To meet DEWA regulations. This option is available for Dubai, U.A.E. only. High & Low Pressure Gauges (SDG) Facry installed for each compressor monir the high side and low side operating pressure. Liquid Line Controls (CRSP) Refrigeration specialties comprising solenoid valve, fi lter drier, sight glass and shuff valve. Facry sizing and selection ensures correctly sized and selected components complete the fi eld installation. Low voltage thermostats (COTS) Wall mounted 4 volts cooling thermostats, supplied loose for field installation. External Overload Protection (EOP) For those electrical specifi cation requires additional overload protection for the compressors. Condenser Coil Guard (CGP) Wire mesh guard, in painted fi nish, for condenser coils. Recommended on ground level installations where coil needs be protected against vandalism. 4
5 ACUMS CADXS Series R SPECIFICATIONS Split Air Conditioner Model ACUMS CADXS Cooling Capacity (1) Cooling Capacity () 50Hz 60Hz MBh kw MBh kw MBh kw MBh kw Capacity Steps % Number of circuits # 1 1 Refrigerant Type 50Hz 60Hz R Condensing Unit ACUMS Type Hermetic Scroll Compressor Qty Type HiX Tubes, Cross Fin Waffle Louver,1 fpi Coil ft 7 10 Face Area m Type Direct Driven Propeller with Aluminium Blade Code / Qty 68 / 1 73 / 1 79 / 1 83 / 1 cfm AFR (50Hz) Fan l/s AFR (60Hz) cfm l/s Type Totally Enclosed Air Over, Class F insulation & IP 55 Mor 50Hz Size kw Hz Size kw Unit Weight (Approximate) lbs kg Fan Coil Unit CADXS Coil Fan Mor Unit Weight (Approximate) Notes: Type Face Area Type Code / Qty AFR Type Size ft m Centrifugal DIDW Belt Driven Y10/1 Y1/1 cfm l/s kw 0.55 Totally Enclosed Fan Cooled, Class F insulation and IP lbs kg (1) The capacity based on evaporar entering air conditions of 80 /67 F (6.7 C/19.4 C) dry bulb/wet bulb and condenser entering air temperature of 95 F (35 C ) () Capacity rating in accordance with AHRI standard 10/40 & 340/ HiX Tubes, Corrugated Fins 1 FPI Table 1 AIR CONDITIONING EQUIPMENT 5
6 SPECIFICATIONS Split Air Conditioner Model Cooling Capacity (1) 50Hz 60Hz SKM Split Air Conditioners ACUMS CADXS Series R ACUMS CADXS MBh kw MBh kw MBh Hz Cooling kw Capacity () MBh Hz kw Capacity Steps % Number of Circuits # 1 1 Refrigerant Type R Condensing Unit ACUMS ACUMS Compressor Type Hermetic Scroll Qty Type HiX Tubes, Cross Fin Waffle Louver,1 fpi Coil ft Face Area m Type Direct Driven Propeller with Aluminium Blade Code / Qty 83 / 1 73 / 79 / 83 / Fan AFR (50Hz) AFR (60Hz) cfm cfm l/s l/s Type Totally Enclosed Air Over, Class F insulation & IP 55 Mor 50Hz Size kw 1.1 x 0.75 x 1.1 x Hz Size kw 1.5 x 1.1 x 1.5 x. Unit Weight (Approximate) lbs kg Fan Coil Unit CADXS Coil Fan Mor Unit Weight (Approximate) Notes: 6 Type Face Area Type Code / Qty AFR Type Size ft 7.1 HiX Tubes, Corrugated Fins 1 FPI m Y1/1 Centrifugal DIDW Belt Driven Y108L/1 cfm l/s kw 1.5 Totally Enclosed Fan Cooled, Class F insulation and IP 55 3 lbs kg Y11L/1 (1) The capacity based on evaporar entering air conditions of 80 /67 F (6.7 C/19.4 C) dry bulb/wet bulb and condenser entering air temperature of 95 F (35 C ) () Capacity rating in accordance with AHRI standard 10/40 & 340/ Table
7 ACUMS CADXS Series R CAPACITY RATINGS (50Hz) ACUMS CADXS AFR cfm l/s EWB Condenser Entering Air Temperature 95 F (35 C) 105 F (41 C) 115 F (46 C) 15 F (51.7 C) Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* (BPF) F C MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw See Notes on page 1 Table 3 AIR CONDITIONING EQUIPMENT 7
8 ACUMS CADXS Series R CAPACITY RATINGS (50Hz) ACUMS CADXS AFR cfm l/s EWB Condenser Entering Air Temperature 95 F (35 C) 105 F (41 C) 115 F (46 C) 15 F (51.7 C) Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* (BPF) F C MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw See Notes on page 1 Table 4 8
9 ACUMS CADXS Series R CAPACITY RATINGS (50Hz) ACUMS CADXS AFR cfm l/s EWB See Notes on page 1 Condenser Entering Air Temperature 95 F (35 C) 105 F (41 C) 115 F (46 C) 15 F (51.7 C) Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* (BPF) F C MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw Table 5 AIR CONDITIONING EQUIPMENT 9
10 ACUMS CADXS Series R CAPACITY RATINGS (60Hz) ACUMS CADXS AFR cfm l/s EWB Condenser Entering Air Temperature 95 F (35 C) 105 F (41 C) 115 F (46 C) 15 F (51.7 C) Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* (BPF) F C MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw See Notes on page 1 Table 6 10
11 ACUMS CADXS Series R CAPACITY RATINGS (60Hz) ACUMS CADXS AFR cfm l/s EWB See Notes on page 1 Condenser Entering Air Temperature 95 F (35 C) 105 F (41 C) 115 F (46 C) 15 F (51.7 C) Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* (BPF) F C MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw Table 7 AIR CONDITIONING EQUIPMENT 11
12 ACUMS CADXS Series R CAPACITY RATINGS (60Hz) ACUMS CADXS AFR cfm l/s EWB Condenser Entering Air Temperature 95 F (35 C) 105 F (41 C) 115 F (46 C) 15 F (51.7 C) Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* Total Capacity Sensible Capacity PI* (BPF) F C MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw MBh kw MBh kw kw Notes: 1. Direct interpolation is permissible. Do not extrapolate.. Shaded area in gray are at 10 F (49 C ) condenser entering air temperature. 3. Ratings are based on 80 F (6.7 C ) evaporar entering air dry bulb temperature. 4. SKM Computer selections are available for quick and accurate selections. * Power input mentioned in this page should not be used for cable or fuse selection. MCA and MFA values given in the electrical data pages (1719) should be referred for the same. Table 8 1
13 ACUMS CADXS Series R Electrical Data Model ACUMS Unit Characteristic MFA MCA ICF AIR CONDITIONING EQUIPMENT Rated Power Supply: V/3Ph/50Hz Compressor Condenser Fan Mor Model Evaporar Fan Mor CADXS QTY RLA LRA QTY FLA LRA FLA LRA Model ACUMS Unit Characteristic MFA MCA ICF Table 9 Rated Power Supply: 440V/3Ph/50Hz Compressor Condenser Fan Mor Model Evaporar Fan Mor CADXS QTY RLA LRA QTY FLA LRA FLA LRA Model ACUMS MFA Unit Characteristic MCA ICF Table 10 Rated Power Supply: 380V/3Ph/60Hz Compressor Condenser Fan Mor Model Evaporar Fan Mor CADXS QTY RLA LRA QTY FLA LRA FLA LRA Table 11 13
14 ACUMS CADXS Series R Electrical Data Model ACUMS MFA Unit Characteristic MCA ICF Rated Power Supply: 460V/3Ph/60Hz Compressor Condenser Fan Mor Model Evaporar Fan Mor CADXS QTY RLA LRA QTY FLA LRA FLA LRA Table 1 Model ACUMS Legend : MFA Unit Characteristic MCA ICF Rated Power Supply: 0V/3Ph/60Hz Compressor Condenser Fan Mor Model Evaporar Fan Mor CADXS QTY RLA LRA QTY FLA LRA FLA LRA Table 13 MFA MCA RLA FLA LRA Maximum Fuse Amperes (for Fuse Sizing) Minimum Circuit Amperes (for wire sizing). Rated Load Amperes Full Load Amperes Locked Ror Amperes Notes : Voltage imbalance between phases be less than %. 14
15 R B B Y R C4 C5 M M SKM Split Air Conditioners ACUMS CADXS Series R Typical Wiring Diagram ACUM Models: 050S~090S, 105S, 15S & 145S, 155S ** ACUM 050S~090S, 105S, 15S, 145S & 155S L1 L L3 N POWER SUPPLY (V/PH/HZ) C4 C3 C C1 OL3 OL OL1 Y B CF1 A C4 CM CFM CFM1 CCH 0~40V CF 4A C R TFR ACUM Models: ACUM 100S, 100S, 110S & 110S 10S & 10S 4V C4 TH(BYOTHERS) CS G Y C1 FCS CR1 CR HPS M OL OL3 OL1 LPS TDR CR1 CR C1 TDR C4 C C3 E (OUT DOOR UNITACUM) * FIELD WIRING BYOTHERS * FIELD W IRING B ET WE EN IND OOR UNIT AND OUT D OOR UNIT FIELD W IRING B ETWEEN BY OTHERS. BY OTHERS. ** EFM CADX (INDOOR UNIT) PROVIDE OVERCURREN SHORT CIRCUIT AND DIS LOCAL &NATIONAL ELE * ** APPLICA ACUM * FIELD W IRING BY OTHERS EFM CADX (INDOOR UNIT) LEGEND C CCH CF CFM CM PROVIDE OVERCURRENT, EARTH FAULTPROTECTION, SHORT CIRCUIT AND DISCONNECT MEANS AS REQUIRED BY LOCAL & NATIONAL ELECTRIC CODE. CS EFM FC S HPS LPS CONTACTOR CRANK CASE HEATER (SELF REGULAT ING TYPE) CONTROL FUSE CONDENSE RFAN MOTOR COMPRESSOR MOTOR CONTROL SWITCH EVAPORATOR FAN MOTOR FAN C YCLING SWITCH HIGH PRESSURE SWITCH LOW PRESSURE SWITCH OL OVERLOAD RELAY TFR TRANSFORMER TH THERMOSTAT TDR TIME DELAY RELAY FIELD WIRINGAND FI ELD SUPP LIED DEVICES APPLICABLE ONLY FOR ACUM 145 & 155 MODELS POWER SUPPLY 380V/3PH/50HZ 400V/3PH/50HZ 415V/3PH/50HZ 380V/3PH/60HZ CF1 A CF 10A C4 C1 OL1 C3 C4 C3 C4 TH ( BY OTHERS) CS1 CS C R G Y1 Y POWER SUPPLY (V/PH/HZ) C3 C OL CM1 CFM 0~40V TFR 4V CR1 C1 CR HPS1 M C1 CR3 HPS M EFM CADX (INDOOR UNIT) CCH1 CCH OL1 OL CM LPS1 TDR1 LPS TDR ** L1 L L3 N E (OUT DOOR UNITACUM) CR1 CR CR3 C1 TDR1 C3 TDR C4 C ACUM Models: 140S, 160S~30S ACUM 140S, 160S~30S * FIELD W IRING BY OTHERS CF1 A CF 10A C4 C5 C1 OL1 CS1 CS R Y TH(BYOTHERS) C R G Y1 Y EF M POW ER SUPPLY (V/PH/HZ) C4 C3 C OL OL3 CFM CFM 1 CCH1 CCH 0~40V TFR 4V CR1 OL1 C1 CR HPS1 C1 CR3 HPS OL FCS1 OL3 FCS CADX (INDOOR UNIT) ** L1 L L3 N C5 CM CM1 CR1 CR CR3 C1 E (O UT DO OR U NITACUM) LPS1 TDR1 TDR1 C4 LPS TDR TDR C5 C C3 15 AIR CONDITIONING EQUIPMENT
16 ACUMS CADXS Series R Field Wiring Requirement Schematic Field Connections ACUMS CADXS series split air conditioners are designed minimum fi eld interaction. Every unit requires at most, fi eld installed disconnect switch or circuit breaker and a 4V control room thermostat. (Cooling/Heating, single stage or two stage) Power hookups, CADXS fan mor power wiring and control wiring of thermostat as per fi eld wiring schematic is all that requires electrically connect any model. All fi eld wiring must be done in accordance with appreciable local and national codes. For recommended maximum fuse sizes and minimum circuit amps for cable sizing refer electrical data on pages 13 & 14. Refer Installation, operation & maintenance manual for full details on fi eld connnections & requirements. Refer typical wiring diagram on page 15 for a schematic representation of required fi eld electrical hookups for a standard ACUMS CADXS series split units. REF. ACTUAL WIRING DIAGRAM FURNISHED WITHTHEUNITFOREXACTIDENTIFICATION OF WIRE NUMBERS. 3PHASE, 3 WIRE SYSTEM 0V/3Ph/60Hz 460V/3Ph/60Hz 440V/3Ph/50Hz L1 L L3 N R Y B GROUND E L1LL3N CIRCUIT BREAKER OR FUSED DISCONNECT SWITCH (NOT BY SKM) 3PHASE, 4 WIRE SYSTEM V/3Ph/50Hz 380V/3Ph/60Hz STARTER FOR CADX (EFM) BUILTIN WITH ACUM PANEL FIELD WIRING BY OTHERS 4V WIRING W W1 Y Y1 G R Com U V W FAN MOTOR ACUMS SERIES CONTROL PANEL CADXS (INDOOR UNIT) ACUMS (OUT DOOR UNIT) ComR GY1YW1 W TYPICAL ROOM THERMOSTAT 1STAGE AND/OR STAGE COOLING/HEATING LINE VOLTAGE FIELD WIRING LOW VOLTAGE FIELD WIRING 16
17 ACUMS CADXS Series R Fan Performance Model CADXS 50 Air Flow Internal Static External Static Pressure, inwg Pressure 0.0(0) 0.1(5) 0.(50) 0.3(75) 0.4(100) 0.5(15) 0.6(150) 0.7(175) 0.8(00) 0.9(5) 1.0(50) RPM Range cfm L/S inwg Pa rpm KW rpm KW rpm KW rpm KW rpm KW rpm KW rpm KW rpm KW rpm KW rpm KW rpm KW 50 Hz 60 Hz Table 14 Notes: 1. Areas shaded in grey indicate operating range outside the standard mor. Shift one step larger mor size in this area (not available for CADX155S & 160S).. Areas shaded in dark grey indicate facry setting ofrpm. 3. Internal static pressure is based on pressure drops through evaporar coil, fan casing and 1 washable fl at fi lter. 4. The shown rpm range is with standard pulley combination as supplied. 5. For dotted area consult SKM AIR CONDITIONING EQUIPMENT 17
18 ACUMS CADXS Series R Weights CADXS MODEL CADXS 050S 070S 090S 100S 105S 110S 15S 155S 160S 0S 40S A1 A A3 A4 44. (0) 45 (0.5) 55 (5) 57.5 (6.) 67.5 (30.8) 87.5 (39.8) 9.5 (4) (50) LOADAT EACH POINT lbs/kg 44. (0) 45 (0.5) 55 (5) 57.5 (6.) 67.5 (30.8) 87.5 (39.8) 9.5 (4) (50) 44. (0) 45 (0.5) 55 (5) 57.5 (6.) 67.5 (30.8) 87.5 (39.8) 9.5 (4) (50) 44. (0) 45 (0.5) 55 (5) 57.5 (6.) 67.5 (30.8) 87.5 (39.8) 9.5 (4) (50) TOTAL WEIGHT lbs(kg) 177 (80) 180 (8) 0 (100) 30 (105) 70 (13) 350 (159) 370 (168) 440 (00) ACUMS MODEL ACUMS 050S 060S 070S 080S 090S 0S 40S A1 75 (34) 77.5 (35) 80 (36.) 91. (41.) LOAD AT EACH POINT lbs/kg A 75 (34) 77.5 (35) 80 (36.) 91. (41.) 105 (47.5) (48.7) 110 (50) (85.) 15 (97.8) 17.5 (98.8) A3 75 (34) 77.5 (35) 80 (36.) 91. (41.) A4 75 (34) 77.5 (35) 80 (36.) 91. (41.) TOTAL WEIGHT lbs(kg) 300 (136) 310 (140) 30 (145) 365 (165) 100S S (47.5) (47.5) (47.5 (190) 110S (48.7) (48.7) (48.7) (195) 10S S (50) (50) (50) (00) 140S,145S 155S,160S 300S 30S (85.) 15 (97.8) 17.5 (98.8) 44.5 (111) 44.5 (111) (85.) 15 (97.8) 17.5 (98.8) 44.5 (111) (85.) 15 (97.8) 17.5 (98.8) 44.5 (111) 750 (341) 860 (391) 870 (395) 977 (444) Fan Coil Unit Models: CADX050S & 070S (40) A1 A M P A3 (40) 5.3 (135) 1.0 (5) LEGEND 1 RETURN AIR CONN. SUPPLY AIR CONN. 3 SUCTIONLINE CONN. 4 LIQUIDLINE CONN. 5 CABLE ENTRY Ø0.6 (15) HOLE 6 FLAT FILTER 1" (5) THK. BACK REMOVAL A 4xØ0.6 (15) HOLE F B E A4 1.0 C (5) A1A4 ARE LOADING POINTS ALL DIMENSIONS ARE ININCHES K D N R Q G S J T H (mm) 3.9 (100) (40) ACCESS PANEL BOTH SIDES 1.4 DRAIN CONN. FPS 3/4"B (19) (35) 1.0 (5) MODEL CADXS 050S 070S A B C D E F G H J K M N P Q R S T SUC. LINE LIQ. LINE CONN. Ø CONN. Ø /8 1/ (980) (1030) (850) (645) (331) (34) (87) (03) (463) (530) (750) (70) (10) (60) (180) (135) (5) (.) (1.7) /8 1/ (1080) (1130) (850) (645) (331) (374) (87) (03) (463) (530) (930) (70) (10) (60) (180) (135) (5) (.) (1.7) 18
19 ACUMS CADXS Series R Fan Coil Unit Models: CADX090S, 105S, 15S 0.75 (19) A1 M P A3 C 0.75 (19) (51) A F B A E A4 (51) 1 (5) D ACCESS PANEL BOTH SIDES R Q K G J LEGEND 1 RETURN AIRCONN. SUPPLY AIR CONN. 3 SUCTION LINE CONN. 4 LIQUID LINE CONN. 5 CABLE ENTRY Ø0.6(15) HOLE 6FLATFILTER 1" (5) THK. BACK REMOVAL 4xØ0.6 (15) A1A4 ARELOADINGPOINTS ALL DIMENSIONS AREININCHES (mm) 1 (5) T DRAIN CONN. (40) FPS 3/4"B (19) MODEL CADXS A B C D E F G H J K M P Q R S T SUC. LINE CONN. Ø 090S /8 (180) (1178) (950) (91) (395) (443) (338) (03) (514) (580) (980) (10) (60) (180) (135) (5) (8.6) 105S /8 (180) (1178) (950) (91) (395) (443) (338) (03) (514) (580) (980) (10) (60) (180) (135) (5) (8.6) 15S /8 (1580) (1478) (950) (91) (395) (593) (338) (03) (514) (580) (1330) (10) (60) (180) (135) (5) (8.6) *5/8 FORCOMBINATIONACUM15S CADX15S (60HZ) 1.18 G (30) H 3.9 (100) 1.4 (35) LIQ. LINE CONN. Ø 1/ (1.7) 1/ (1.7) 1/* (1.7) 1 (5) Fan Coil Unit Models: CADX 100S & 110S C 0.75 (19) A1 M P A3 4xØ0.6 (15) 0.75 (19) (51) A F B A E A4 (51) D 1 (5) R ACCESS PANEL BOTH SIDES Q G 3.9 (100) G 1 (5) H N K J T MODEL CADXS 100S 110S A 50.4 (180) 6. (1580) B 46.4 (1178) 58. (1478) C 37.4 (950) 37.4 (950) D 35.9 (91) E 15.6 (395) F (91) (395) (443) (338) (03) 3.3 (593) G 13.3 (338) H 8 (03) 1.18 (30) J 0. (514) 0. (514) (40) DRAIN CONN. FPS 3/4"B (19) K M N P Q R S T SUC. LINE CONN. Ø x7/8 (580) (980) (389) (10) (60) (180) (135) (5) x (.) x7/8 (580) (1330) (389) (10) (60) (180) (135) (5) x (.) 1.4 (35) LIQ. LINE CONN. Ø x1/ x (1.7) x1/ x (1.7) 1 (5) 19 AIR CONDITIONING EQUIPMENT
20 Fan Coil Unit Models: CADX 155S SKM Split Air Conditioners ACUMS CADXS Series R 0.9 [4] M LEGEND Ø0.6 (15) (x4 HOLES) 1 RETURN AIR CONN. SUPPLY AIR CONN. 3 SUCTION LINE CONN. 4 LIQUID LINE CONN. 5 CABLE ENTRY Ø0.6(15) HOLE 6 FLAT FILTER 1" (5) THK. BACK REMOVAL A1A4 ARE LOADING POINTS ALL DIMENSIONS ARE IN INCHES (mm) B A 1.0 [5] C R 1.0 [5] E Q L K J T D A1 A3 N A A4 F 6 1 H G [38] ACCESS PANEL BOTH SIDES 5 DRAIN CONN. FPS 1"B[5] x Nos. 3.1 [80] MODEL CADXS 155S A (165) B 65.9 (1675) C 31.5 (800) D 1. (538) E 9.3 (744) F 13.9 (353) G 11.3 (87) H (59) J 0.9 (53) K 5. (640) L M (135) (1483) N 4.0 (10) T 3.5 (90) Q.4 (60) R 7.1 (180) SUC. LINE CONN. Ø 11/8 (8.6) LIQ. LINE CONN. Ø 5/8 (15.9) Fan Coil Unit Models: CADX160S, 0S, 40S 0.9 [4] M A1 A3 B A 1.0 [5] C R 1.0 [5] F E Q S 0 K T H J G D Ø0.6 (15) (x4 HOLES) A N A [38] ACCESS PANEL BOTH SIDES 5 DRAIN CONN. FPS 1"B [5] x Nos. 3.1 [80] MODEL LIQ. LINE L O P Q SUC. LINE CADXS A B C D E F G H J K M N R CONN. Ø CONN. Ø 160S x11/8 x 1/ (165) (1675) (800) (538) (744) (353) (87) (59) (53) (640) (135) (1483)(10) (414) (90) (60) (180) x (8.6) x (1.7) 0S x11/8 x1/ (1980) (005) (800) (559) (1114) (0) (338) (46) (735) (845) (135) (1475) (81) (516) (90) (60) (180) x (8.6) x (1.7) x11/8 x5/8 40S (1980) (030) (800) (559) (1114) (46) (338) (46) * (735) (845) (135) (183) (81) (516) (90) (60) (180) x (8.6) x (15.9) * 1/ FOR COMBINATION ACUM40S CADX40S (50 HZ) 0
21 ACUMS CADXS Series R Condensing Unit Dimensional Data Models: ACUM 050S, 060S, 070S & 080S 4Ø0.79 [0] HOLES FOR ANCHOR BOLTS A1 A3 3 AIR IN LEGEND 1 CONDENSER FAN CONTROL PANEL 3 CONDENSER COIL 4 COMPRESSOR A A4 [51] 7 [686] [51] 1 31 [787] AIR OUT 36 [914] AIR IN 43.9 [1115] SUCTIONØ 7/8[] LIQUIDØ 1/ [13] [3] 1.9 [48] CABLE ENTRY HOLE WITH RUBBER GROMMET ACCESS PANEL FOR COMPRESSOR 36 [914] [50] Condensing Unit Dimensional Data Models: ACUM 090S, 100S, 105S, 110S, 10S & 15S AIR IN 3 A1 A 4Ø0.79[0] HOLES FOR ANCHOR BOLTS A [901] A4 ACUMS CONNECTIONØ MODELS SUC.Ø#1 LIQ.Ø#1 SUC.Ø# LIQ.Ø# *090S 11/8 [9] 1/ [13] 100S 7/8 [] 1/ [13] 7/8 [] 1/ [13] *105S 11/8 [9] 5/8 [16] 110S 7/8 [] 1/ [13] 7/8 [] 1/ [13] 10S 7/8 [] 1/ [13] 7/8 [] 1/ [13] *15S 11/8 [9] 5/8 [16] * MODEL WITHONECOMPRESSOR ALL DIMENSIONSAREININCHES [MM] A1A4 ARELOADINGPOINTSØ.79 [0] [981] AIR OUT 46.3 [1175] AIR IN ACCESS PANEL FOR COMPRESSOR 43.9 [1115] SUC.Ø 4 LI Q.Ø [50] 10.7 [7] ACUM 100S, 110S, 10S 13.9 [35] 1.9 [48] 1. 9 [48] CABLE ENTRY HOLE WITH RUBBER GROMMET 46.3 [1175] ACUM 105S, 15S 13.6 [345] 1.9 [48] SUC. Ø LIQ. Ø ACUM 090S 10.7 [7] 1.9 [48] SUC. Ø LIQ. Ø 1 AIR CONDITIONING EQUIPMENT
22 ACUMS CADXS Series R Condensing Unit Dimensional Data MODELS: Models: ACUM140S, 145S, 155S, 160S, 0S & 40S A1 A3 AIR IN A 3.5 [85] A4 AIR IN 43.9 [1115] 4Ø0.6 [15] HOLES (FOR ANCHOR BOLTS) ACUMS CONNECTIONØ MODELS SUC.Ø#1 LIQ.Ø#1 SUC.Ø# LIQ.Ø# 7/8 1/ 7/8 1/ 140S [] [13] [] [13] * * * 145S 155S 160S 0S 40S 11/8 [9] 11/8 [9] 11/8 [9] 11/8 [9] 5/8 [16] 5/8 [16] 1/ [13] 5/8 [16] 11/8 [9] 11/8 [9] 5/8 [16] MODEL WITH ONE COMPRESSOR ALL DIMENS IONS ARE IN INCHES [MM] A1A 4 A RE L OADING PO INTS Ø.79 [0 ] 1/ [13] 11/8 5/8 11/8 5/8 [9] [16] [9] [16] [1785] 4.3 [1075] AIR OUT AIR OUT AIR IN AIR IN CABLEENTRY HOLES WITH RUBBER GROMMET [1100].38 [60] 49 [145] CONN. FOR MODEL A CUM 140S, 160S, 0S, 40S LIQ.Ø5/8[16] SUC.Ø1 1/8 [9] [50].0.0[50] SUC.Ø1 1/8 [65] [60] LIQ.Ø5/8 [16] [9] CONN. FOR MODEL ACUM 145S, 155S [50].0 [65].6 Condensing Unit Dimensional Data Models: ACUM 300S, 30S 4Ø0.79 [19] HOLES (FOR ANCHOR BOLTS) A1 A3 AIR IN AIR IN LEGEND 1 CONDENSER FAN CONTROL PANEL 3CONDENSER COIL 4 COMPRESSOR A [100] A [03] [1500] AIR OUT 1 AIR OUT AIR IN AIR IN CABLE ENTRY HOLES WITH RUBBER GROMMET RIGGING HOLES Ø0.79[0] x 4Nos [14] [100] [1370] [1515] 4 LIQ.Ø5/8 [16] SUC.Ø1 1/8[9] [50].0 [60].4.0 [50] LIQ.Ø5/8[16] SUC.Ø1 1/8[9]
23 ACUMS CADXS Series R GUIDE SPECIFICATIONS GENERAL Split air conditioner shall be composed of a ceiling suspended indoor fan coil unit & floor mounted outside air cooled condensing unit, rated in accordance with ARI standards 10 / 4094 and The indoor and outdoor units shall be facry assembled, internally wired, charged with R and fully tested. Unit should be capable operate in a wide range of ambient temperatures from 50 F (10 C) 15 F (51.7 C) and shall be selected in accordance with project requirements and installed as per Instruction, Operation & Maintenance Manual. COOLING UNIT Evaporar Evaporar coil shall be constructed of HiX seamless copper tubes 3/8 OD mechanically bonded aluminum (copper) crosswave fins with maximum 1 fpi (.1mm) spacing. Coil consists of headers of seamless copper tubing, thermostatic expansion valve(s) & multicircuited distribur(s). These coils shall be tested against leakage by air pressure of 300 psig (608 Kpa) under water, cleaned & dehydrated at the facry. Coil shall conform AHRI 410. CONDENSING UNIT The condensing Unit shall be composed of Compressor(s), coil(s) and condenser fan(s). COMPRESSOR Compressors used are hermetically sealed, compact scroll as standard. All standard controls and accessories necessary for safe operation were all provided. Compressors are equipped with internal mor protecr, facry installed crank case heater and rubber grommets/vibrationisolar for controlling structural vibration and with quiet and eff cient operation. CONDENSER COIL(S) Condenser coils shall be air cooled with integral sub cooler, constructed of HiX seamless copper tubes 3/8 OD mechanically expanded in wavy plate type aluminum fi ns with maximum 1 fpi (.1mm) spacing. These coils shall be tested against leakage by air pressure of 450 psig (3100 Kpa) under water, cleaned & dehydrated at the facry. Coil shall conform ARI410/91. CONDENSER FAN(S) & MOTOR(S) Condenser Fans shall be direct driven propeller type discharging air vertically upward, equipped with statically & dynamically balanced aluminum alloy blades, inherent corrosion resistant shaft & PVC coated steel wire fan guard. Condenser fan mor(s) shall be Totally Enclosed Air Over (TEAO), 6 poles with classf insulation, minimum IP55 protection & wired unit control panel. Evaporar Fan & Mor Fans of evaporars shall be forward curved, double inlet double width (DIDW), centrifugal type, statically & dynamically balanced, mounted on a single heavy duty shaft with permanently lubricated bearings & driven by V belt with an adjustable variable pitch mor pulley. Mor shall be Totally Enclosed Fan Cooled (TEFC), 4 poles, classf insulated, minimum IP55 protection and starter for the mor shall be provided in the matching condensing unit ACUM control panel, if ordered. Filter(s) Cooling unit shall be provided with cleanable media, easy access, and minimum 1 thick coarse filter having average extraction efficiency of 75% as per ASHRE standards 576 or equivalent DIN Casing Units casing shall be made of Zinc coated galvanized steel sheets conforming JISG330 and ASTMA55 that shall be phosphatized and then elctrostatically dry powder coated of approx 60 microns provide an extremely ugh, scratch resistance, excellent anti corrosive protection that can pass 1000 hours in 5% salt spray testing at 95 F relative humidity as per ASTM B Casing shall be provided with access panels for easy service and maintenance & insulated with ½ (13.0mm) thick fibreglass insulation as per NFPA 90A and 90B for fire resistance. Controls Condensing unit shall be provided with a weatherproof control panel enclosure comprising all electrical control devices except for the field supplied room thermostat and shall include the following components as minimum. Compressor contacr Condenser fan mor contacrs and overload relays High / low pressure switch Anti recycling time delay relay 4volt control transformer for remote thermostat connection Terminal for evaporar fan mor interlock Split system shall be supplied with facry sized liquid line controls (Shut off valve, filter drier, sight glass and solenoid valves, if so specifi ed. 3 AIR CONDITIONING EQUIPMENT
24 ACUMS CADXS Spare Series Parts Division R HEAD OFFICE P.O Box: 6004 Sharjah, United Arab Emirates Tel: Fax: sales@skm.ae Sharjah, United Arab Emirates Tel: Fax: spareparts@skm.ae Service Centre Sharjah, United Arab Emirates Tel: Fax: aftersales@skm.ae UAE Abu Dhabi P.O Box: 7788 Abu Dhabi, United Arab Emirates Tel: Fax: abudhabisales@skm.ae Al Ain Al Ain, United Arab Emirates Tel: Fax: alainsales@skm.ae Dubai P.O Box: 988 Dubai, United Arab Emirates Tel: Fax: dubaisales@skm.ae Kuwait P.O Box: 115PC Dasman, Kuwait Tel: Fax: kuwaitsales@skm.ae Saudi Arabia mdaqqa@fawaz.com Dammam Fawaz Ref. & Air Conditioning Co. P.O Box: 1189 Al Khobar, Saudi Arabia Tel: Fax: abarbarawi@fawaz.com Jeddah Fawaz Ref. & Air Conditioning Co. P.O Box: 1318 Jeddah, Saudi Arabia Tel: Fax: jrabdu@fawaz.com Riyadh Fawaz Ref. & Air Conditioning Co. P.O Box: 8513 Riyadh, Saudi Arabia Tel: Fax: szaidan@fawaz.com Jordan Ideal A/C Systems Co. L.L.C Al Gardenz Street, Building 111, Al Bakri Complex P.O Box 550 Amman, Jordan Tel: Fax: tariq@idealac.com REGIONAL OFFICES DISTRIBUTORS Saudi Arabia AL Messila HVAC Equipment Facry (Part of SKM A/C facry in Saudi Arabia) Saudi Arabia, Eastern provenance AD Dammam nd industrial city Abqiq main road Hail Street Tel: / 4 / 5 Fax: / Egypt 9 Mosadak Street, 3 rd floor, Dokki, Giza, Egypt Tel: / Fax: egyptsales@skm.ae Algeria Aissat Idir ( EXENMA) City Bldg1, Flat, Dar El Beida Algiers, Algeria Tel: Fax: algeriasales@skm.ae Qatar Mannai Trading Co. WLL P.O Box: 76 Doha, Qatar Tel: / Fax: dohasales@skm.ae HVAC@mannai.com.qa Iraq Al Rawbitt Al Iraqia Co. Erbil Bagdad Basra Tel: info@alrawabitt.com Kuwait (for Unitary Products Only) British Link Kuwait (BLK) P.O Box: Al Nuzha Tel: Fax: rawad@blk.com.kw Forest (Global Distribur for Minisplit, VRF & Window) Head Office Kuwait Tel: Ext 500 Fax: forest@forestunited.com website: 4 visit us at 104/014 A
R-22. M-S Series Packaged Air Conditioners. Range 4 TR to 31 TR (14 kw to 110 kw) Sharjah Economic Excellence Award winner
R-22 -S Series Packaged ir Conditioners Range 4 TR to 31 TR (14 kw to 110 kw) facebook.com/skmuae www.skm.ae youtube.com/marketingskm Sharjah conomic xcellence ward winner SK Packaged ir Conditioners Introduction
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationR-22. ACUF-Series Air Cooled Condensing Units. SKM Air Cooled Condensing Units ACUF Series - R-22. Range 11 TR to 119 TR (40 kw to 420 kw)
R22 Series Air Cooled Condensing Units Range 11 TR to 119 TR (40 kw to 420 kw) facebook.com/skmaircon www.skmaircon.com @skmaircon Sharjah Economic Excellence Award winner 1 Contents Introduction...2 Legend...
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationPCB COMMERCIAL SERIES
PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner
More informationACUS-Series Air Cooled Condensing Units
Series R & R07C R/R07C Series Air Cooled Condensing Units Range 5 TR to 07 TR (7 k to 375 k) facebook.com/skmaircon www.skmaircon.com @skmaircon Sharjah Economic Excellence Award winner Series R & R07C
More informationR-134a. ACUV-D Series Air Cooled Condesing Units. SKM Air Cooled Condensing Units ACUV-D Series - R-134a.
SKM Air Cooled Condensing Units R134a D Series Air Cooled Condesing Units Range 8 TR to 142 TR (27 kw to 501 kw) facebook.com/skmaircon www.skmaircon.com @skmaircon Sharjah Economic Excellence Award winner
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationPACL Series Packaged Air Conditioners
PL Series - - - 50HZ PL Series Packaged ir onditioners ange T to 7.5 T ( kw to 97 kw) facebook.com/skmaircon www.skmaircon.com @skmaircon PL Series - - ontents Legend...0 Nomenclature... 0 Introduction...0
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationDESCRIPTION FEATURES
SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More information42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option
42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater
More informationRCD Air Cooled Condensing Unit (50/60 Hz)
Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)
-P Series 50Hz Rooftop Units Cooling Capacity : to 388 MBH (8 to 407 kw) Heating Capacity : 8 to 98 MBH (8 to 380 kw) 40A Products that perform...by people who care NOMENCLATURE AC P S E 435 P HP G Q Air
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More informationPHB SERIES 7-1/2 and 10 TON
PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationS3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant
TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationSINGLE PACKAGE AIR CONDITIONING WATER COOLED
MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationProduct Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil
FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationR-134a. APCY Series Screw Chillers. SKM Compact Screw Chillers APCY Series - R-134a. Range 50 TR to 455 TR (176 kw to 1600 kw)
SKM Compact Screw Chillers APCY Series - R-34a R-34a APCY Series Screw Chillers Range 50 TR to 455 TR (76 kw to 600 kw) facebook.com/skmaircon www.skmaircon.com @skmaircon Sharjah Economic Excellence Award
More informationProduct Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)
Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)
550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped
More informationGSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h
Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling
More informationFFQN-C, FCRN-E, FFRN-C
R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii
More informationS6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.
TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationN4A6. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES
(791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely
More information36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH
36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua
More informationDZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h
Split-System heat pump Up to 14 SEER / R-410A Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air
More informationProduct Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES
FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system
More informationProduct Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons
Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers
More informationGPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER
Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit
More information24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)
24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More informationProduct Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )
13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation
More informationFMU4X, FMC4X FMU4Z, FMC4Z
HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,
More informationMHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3
MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model
More informationAddress: VTS Clima L.L.C.
Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS
More informationLOW STATIC FAN COIL UNITS District Cooling Chilled Water Application
STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications
More informationMH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil
MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000
More informationNOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)
NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationProduct Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES
Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split -system heat pumps and air
More informationDX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h
DX11S Commercial Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube / aluminum fin coil Brass liquid and suction service valves High- and low-pressure
More informationGSC13 Split System Air Conditioner
Split System Air Conditioner 13 SEER / R-22 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 AHRI Ratings... 18 Wiring Diagram... 19 Dimensions... 20 Accessories...
More informationWCA4**4. Product Specifications
WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More informationR4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)
FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-
More informationCFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationSerenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog.
Serenity GT Series Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog Table of Contents: Product Introduction & Unit Features...2 Performance Data: AHRI - Single Compressor...3
More informationQ6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.
TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed
More informationAIR COOLED CHILLERS WATER COOLED CHILLERS
AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with
More informationN4A4 C. Product Specifications
COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier
More informationSSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H
PRODUCT SPECIFICATIONS 14 SEER / R-410A 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER The Goodman Air Conditioner uses the environmentally friendly refrigerant
More informationProduct Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS
DUCTED HEAT PUMP Sizes 018 To 060 1.5 To 5 Nominal Tons Product Data A08379 INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S Sound S Levels as low as 71 dba Design Features S New aesthetics S Small
More informationSSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON
HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP The Goodman uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry.
More informationCHP
Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level
More informationProduct Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits
More informationGQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged
More informationLUI / LUO. Condensing Units
UI / UO Condensing Units Standard Construction Cabinet: The rugged cabinet is constructed of heavy gauge, mill galvanized steel. Easily removable top and personnel screen are provided for convenient component
More informationLIST PRICES WAC AIR CURTAINS
PRICE SHEET PSWAC-2 EFFECTIVE: March 1, 2011 SUPERSEDES: PSWAC-1 LIST PRICES WAC AIR CURTAINS 4830 TRANSPORT DRIVE, DALLAS, TX 75247 PHONE: 214-638-6010 FAX: 214-905-0806 WAC AIR CURTAINS Basic Unit ITEM
More informationFORM NO. PTZ-806 REV. 1 HEAT PUMPS
FORM NO. PTZ-806 REV. 1 TZPLS-14 SERIES Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured for Thermal
More informationSection 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH
AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized
More informationProduct Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES
LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air
More informationTons BTU/h S.E.E.R* E.E.R** HSPF
SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum
More informationQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS
TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged
More informationTECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS
TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal
More informationWATER SOURCE HEAT PUMPS
HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units
More informationProduct Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES
FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More informationP6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units
TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility
More informationSSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF
High-Efficiency Cooling Capacity: 18,000 to 57,600 BTU/h Heating Capacity: 18,000 to 59,000 BTU/h Split System Heat Pump Up to 15 SEER & 8.5 HSPF Contents Nomenclature... 2 Product Specifications... 3
More information38P 60Hz Nominal Cooling Capacity Tons HFC R -410A Refrigerant
38P Condensing Units 60Hz 38P 36K 60K 38P 18K 24K Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturer s Name: Saudi Airconditioning Manufacturing
More informationODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz
ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz Condensing Models TTK 060 KD TTA 075 RD TTA 100 RD TTA 120 RD TTA 150 RD TTA 180 RD TTA 200 RD TTA 240 RD Air
More informationPACKAGE AIR CONDITIONERS
PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0
More informationCFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15
ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
CHS Product Specifications COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on 0 to 121 models, two stage cooling
More informationTECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz
TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS
(1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece
More informationengineering guide Air-Cooled Self-Contained Units
engineering guide Air-Cooled Self-Contained Units FORM 145.00-EG2 (1211) TABLE OF CONTENTS Air-Cooled Self-Contained Units Introduction...............................................................................
More informationSizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions
PHH Product Specifications COMMERCIAL HIGH EFFICIENCY PACKAGE HEAT PUMP UNITS R 22, SINGLE PACKAGE ROOFTOP, 3 15 TONS (3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE One piece, high efficiency heat
More information