2 VORT QUADRO EVO RANGE Centrifugal extractor fans for wall/ceiling and flush mounting CONSTRUCTION: VENTILATION UNIT: AC motor, shaft on ball bearings, granting continuous operation for more than hours. Forward curved centrifugal impeller, PBT made, granting high rigidity, dimensional stability and great resistance to aggressive chemical agents. Its high efficiency, resulting from accurate aerodynamics studies, grants high pressure levels in a wide range of airflows. Scroll, comprehending the electronic cardboard housing, made of self-extinguishing ABS, rated V0. Aesthetic front panel, made of self-extinguishing ABS, V0 rated, wave shaped for perimeter extraction. A hinge allows a wide rotation angle for easy filter maintenance. Motor housing and filter frame made of ABS plastic. G2 filter, with a clogged filter mechanic alarm. Electronic Suite. Splash-proof protection (rating IP45), allowing their installation in Zone 1 of bathrooms. 2

3 RESIDENTIAL VENTILATION CONSTRUCTION: CASINGS EXTERNAL/RECESSED MOUNTINGS: 10 casings, different for installation and fire protection (K90). Casings integrate a nominal 80 mm diameter spigot and a backdraught shutter. Casings will be also provided with a frame to prevent entry of dirt and plaster. Example: recessed casing Example: external casing 3

4 VORT QUADRO EVO RANGE Centrifugal extractor fans for wall/ceiling and flush mounting RANGE: + VENTILATION UNITS: 23 models motor fans different for 5 electronic Suite and 5 level of performance. CASINGS EXTERNAL/RECESSED MOUNTINGS: 10 casings, different for installation and fire protection (K90). VENTILATION UNITS: BASIC VERSION: QE 60 LL Ventilation unit with front panel, 1 speed with air volume 60 m 3 /h QE 60/35 LL Ventilation unit with front panel, 2 speeds with air volume 60/35 m 3 /h QE 100 LL Ventilation unit with front panel, 1 speed with air volume 100 m 3 /h QE 100/60 LL Ventilation unit with front panel, 2 speeds with air volume 100/60 m 3 /h QE 100/60/35 LL Ventilation unit with front panel, 3 speeds with air volume 100/60/35 m 3 /h TIMER VERSION (T): QE 60 LL T QE 60/35 LL T QE 100 LL T QE 100/60 LL T Ventilation unit with front panel, 1 speed with air volume 60 m 3 /h and timer. Ventilation unit with front panel, 2 speeds with air volume 60/35 m 3 /h and timer. Ventilation unit with front panel, 1 speed with air volume 100 m 3 /h and timer. Ventilation unit with front panel, 2 speeds with air volume 100/60 m 3 /h and timer. TIMER EVO VERSION (TP): QE 60 LL TP QE 60/35 LL TP QE 100 LL TP QE 100/60 LL TP QE 100/60/35 LL TP Ventilation unit with front panel, 1 speed with air volume 60 m 3 /h and timer plus. Ventilation unit with front panel, 2 speeds with air volume 60/35 m 3 /h and timer plus. Ventilation unit with front panel, 1 speed with air volume 100 m 3 /h and timer plus. Ventilation unit with front panel, 2 speeds with air volume 100/60 m 3 /h and timer plus. Ventilation unit with front panel, 3 speeds with air volume 100/60/35 m 3 /h and timer plus. 4

5 RESIDENTIAL VENTILATION VENTILATION UNITS: TIMER + PIR SENSOR (T PIR): QE 60 LL T PIR QE 60/35 LL T PIR QE 100 LL T PIR QE 100/60 LL T PIR TIMER EVO + HCS SENSOR (TP HCS): Ventilation unit with front panel, 1 speed with air volume 60 m 3 /h, timer and PIR sensor. Ventilation unit with front panel, 2 speeds with air volume 60/35 m 3 /h timer and PIR sensor. Ventilation unit with front panel, 1 speed with air volume 100 m 3 /h, timer and PIR sensor. Ventilation unit with front panel, 2 speeds with air volume 100/60 m 3 /h, timer and PIR sensor QE 60 LL TP HCS QE 60/35 LL TP HCS QE 100 LL TP HCS QE 100/60 LL TP HCS QE 100/60/35 LL TP HCS Ventilation unit with front panel, 1 speed with air volume 60 m 3 /h, timer plus and humidity sensor. Ventilation unit with front panel, 2 speeds with air volume 60/35 m 3 /h timer plus and humidity sensor. Ventilation unit with front panel, 1 speed with air volume 100 m 3 /h, timer plus and humidity sensor. Ventilation unit with front panel, 2 speeds with air volume 100/60 m 3 /h, timer plus and humidity sensor. Ventilation unit with front panel, 3 speeds with air volume 100/60/35 m 3 /h, timer plus and humidity sensor. CASINGS EXTERNAL/RECESSED MOUNTINGS: BASIC FOR INSTALLATION ON WALLS AND CEILINGS: QE - B M Wall-mounted casing without fire protection with regular backdraft shutter. BASIC FOR INSTALLATION ON WALLS AND CEILINGS WITH FIREPROOF CLASS, BACKDRAUGHT SHUTTER: QE - B M VK90 Wall-mounted casing with fire protected K90 backdraft shutter. BASIC FOR RECESSED INSTALLATION: QE - B I Flush-mounted casing without fire protection with regular backdraft shutter. 5

6 VORT QUADRO EVO RANGE Centrifugal extractor fans for wall/ceiling and flush mounting CASINGS EXTERNAL/RECESSED MOUNTINGS: BASIC FOR RECESSED INSTALLATION WITH FIREPROOF CLASS, BACKDRAUGHT SHUTTER: QE - B I VK90 Flush-mounted casing with fire protected K90 backdraft shutter. RECESSED INSTALLATION FIREPROOF ENCASEMENT, WITH FIREPROOF CLASS BACKDRAUGHT SHUTTER : QE - B I K90 R Flush-mounted fireproof K90 casing with fire protected K90 backdraft shutter, discharge spigot on the rear QE - B I K90 S Flush-mounted fireproof K90 casing with fire protected K90 backdraft shutter, discharge spigot on the side QE - B I K90 R 2R Flush-mounted fireproof K90 casing with fire protected K90 backdraft shutter, discharge spigot on the Rear and spigot for second room ventilation on the right QE - B I K90 R 2L Flush-mounted fireproof K90 casing with fire protected K90 backdraft shutter, discharge spigot on the Rear and spigot for second room ventilation on the left QE - B I K90 S 2R Flush-mounted fireproof K90 casing with fire protected K90 backdraft shutter, discharge spigot on the Side and spigot for second room ventilation on the Right 6

7 RESIDENTIAL VENTILATION CASINGS EXTERNAL/RECESSED MOUNTINGS: RECESSED INSTALLATION FIREPROOF ENCASEMENT, WITH FIREPROOF CLASS BACKDRAUGHT SHUTTER : QE - B I K90 S 2L Flush-mounted fireproof K90 casing with fire protected K90 backdraft shutter, discharge spigot on the Side and spigot for second room ventilation on the left. TECHNICAL DATA: CODE MODEL W A AIRFLOW (l/s) m 3 /h SOUND LEVEL Lw db(a) 3m Lp db(a) PRESSURE (mmh20) (Pa) RPM QE 60 LL 16 0,14 16, , QE 100 LL 26 0,17 27, , QE 60/35 LL 16/9 0,14/0,11 16,7/9,7 60/35 45,5/37,3 25/16,8 35/10 343/ / QE 100/60 LL 26/16 0,17/0,14 27,8/16,7 100/60 52/45,5 31,5/25 36/35 353/ / QE 100/60/35 LL 26/16/9 0,17/0,14/0,11 27,8/16,7/9,7 100/60/35 52/45,5/37,3 31,5/25/16,8 36/35/10 353/343/ /1170/ QE 60 LL T 16 0,14 16, , QE 100 LL T 26 0,17 27, , QE 60/35 LL T 16/9 0,14/0,11 16,7/9,7 60/35 45,5/37,3 25/16,8 35/10 343/ / QE 100/60 LL T 26/16 0,17/0,14 27,8/16,7 100/60 52/45,5 31,5/25 36/35 353/ / QE 60 LL TP 16 0,14 16, , QE 100 LL TP 26 0,17 27, , QE 60/35 LL TP 16/9 0,14/0,11 16,7/9,7 60/35 45,5/37,3 25/16,8 35/10 343/ / QE 100/60 LL TP 26/16 0,17/0,14 27,8/16,7 100/60 52/45,5 31,5/25 36/35 353/ / QE 100/60/35 LL TP 26/16/9 0,17/0,14/0,11 27,8/16,7/9,7 100/60/35 52/45,5/37,3 31,5/25/16,8 36/35/10 353/343/ /1170/ QE 60 LL TP HCS 16 0,14 16, , QE 100 LL TP HCS 26 0,17 27, , QE 60/35 LL TP HCS 16/9 0,14/0,11 16,7/9,7 60/35 45,5/37,3 25/16,8 35/10 343/ / QE 100/60 LL TP HCS QE 100/60/35 LL TP HCS 26/16 0,17/0,14 27,8/16,7 100/60 52/45,5 31,5/25 36/35 353/ / /16/9 0,17/0,14/0,11 27,8/16,7/9,7 100/60/35 52/45,5/37,3 31,5/25/16,8 36/35/10 353/343/ /1170/ QE 60 LL T PIR 16 0,14 16, , QE 100 LL T PIR 26 0,17 27, , QE 60/35 LL T PIR 16/9 0,14/0,11 16,7/9,7 60/35 45,5/37,3 25/16,8 35/10 343/ / QE 100/60 LL T PIR 26/16 0,17/0,14 27,8/16,7 100/60 52/45,5 31,5/25 36/35 353/ /1170 (V) , (HZ) 50, ( C) 50. 7

8 VORT QUADRO EVO RANGE Centrifugal extractor fans for wall/ceiling and flush mounting DIMENSIONAL DATA: G B D B H ØF ØE A D C External mounting ØF ØE G A H C Recessed mounting MODELS A B C D E F G H Kg External , Recessed , Dimension (mm) 8

9 RESIDENTIAL VENTILATION CURVES: FOR MODELS: - QE 60 LL (cod ) - QE 60/35 LL (cod ) - QE 60 LL T (cod ) - QE 60/35 LL T (cod.11528) - QE 60 LL TP (cod ) - QE 60/35 LL TP (cod ) - QE 60 LL TP HCS (cod ) - QE 60/35 LL TP HCS (cod.11541) - QE 60 LL T PIR (cod ) - QE 60/35 LL T PIR (cod ) FOR MODELS: - QE 100 LL (cod ) - QE 100/60 LL (cod ) - QE 100 LL T (cod ) - QE 100/60 LL T (cod ) - QE 100 LL TP (cod ) - QE 100/60 LL TP (cod ) - QE 100 LL TP HCS (cod ) - QE 100/60 LL TP HCS (cod ) - QE 100 LL T PIR (cod ) - QE 100/60 LL T PIR (cod ) FOR MODELS: - QE 100/60/35 LL (cod ) - QE 100/60/35 LL TP (cod ) - QE 100/60/35 LL TP HCS (cod ) PERFORMANCE CURVES max med min 9

10 VORT QUADRO EVO RANGE Centrifugal extractor fans for wall/ceiling and flush mounting APPLICATIONS: Example: Recessed Casings mounting cod with Timer (T) motor fan cod ; 10

11 RESIDENTIAL VENTILATION APPLICATIONS: Example: Recessed installation fireproof encasement K90, with fireproof class K90 backdraught shutter cod with Timer EVO (TP) motor fan cod ; Example: External Casings mounting cod with basic motor fan cod ; 11

12 Vortice Elettrosociali S.p.A Strada Cerca, 2 Frazione di Zoate Tribiano (Milano) Tel. (+39) Fax (+39) Italia Vortice France 15-33, Rue Le Corbusier CS Créteil Cedex Tél. (+33) Fax (+33) France Vortice Limited Beeches House-Eastern Avenue Burton on Trent DE13 0BB Tel. (+44) Fax (+44) United Kingdom The description and illustrations in this catalogue are understood to be indicative and are not binding. Vortice reserves the right, while not changing the essential characteristcs of the models described and illustred, to modify products whenever necessary and without warning.