RADIAL ALUMINUM LOW PRESSURE

Size: px
Start display at page:

Download "RADIAL ALUMINUM LOW PRESSURE"

Transcription

1 RADIAL ALUMINUM LOW PRESSURE Content LOW PRESSURE BLOWERS... 2 GENERAL... 3 D03M, E D04M, E D045M, E D05M, E D052M, E D060, E D064, E D066, E D07, D D08, D D09, D Blowers in twin models D D D D D D D D D ACCESSORIES

2 LOW PRESSURE BLOWERS Feature of this direct drive blowers is the aluminum housing with radial impeller wide forward curved blades. With a stocky build this ensures particularly quiet operation. The suction side is provided with a protective netting, there may possibly be a suction inlet to be mounted. We can also supply an extensive range of accessories. All fans are available in 8 positions, would like before ordering to make a choice in clockwise or counterclockwise rotation, the position of the snail shell can be decide for yourself. The motor can be mounted both horizontally and vertically. The blowers are in standard version for temperatures up to 50 C, for temperatures up to 180 C can be a hot soak clutch built, suitable type S484. The motors IP54 equipped with a voltage of 230 volts or 230/400 volts to 3 kw., Above 400/690 Volt. The default frequency is 50 Hz., Other voltages and 60 Hz. are also possible. The motors above 0,75 kw are IE3. The blowers can also be supplied with an electronically controlled engine, this concerns the types RVE. If there is dirt on the media, we recommend a filter. For suction operation of the blower should be 80% of the fan capacity take. The sound data obtained by measurement with an open suction inlet at 1 meter. All blowers are suitable for continuous operation. The impeller and the snail shells can be supplied in stainless steel. 2

3 GENERAL Clockwise Counter Clockwise All blowers can be supplied in various positions according to the above pictures. As standard we deliver the right (clockwise) model AR. If you want a left version (counter clockwise) and the base is molded, it must be in advance indicate this. With a removable base the snail shall can be turned, but one must then assemble a left impeller. When a channel on the discharge side connection of the same diameter as the blower mouth then P-dyn.2 as pressure drop indicated. If a larger channel mounted then, the dynamic pressure is considerable smaller and can be used as static pressure. At 100% bigger will win about 55% back. Suction side does not affect because of diffusion effects. Total pressure Blower characteristic B Capacities B pressure profit at increasing blow channel P dyn. 2 Characteristic A 3

4 D03M, E03 S484 version total length 227 mm. Max. Airflow Max. Pressure Voltage Frequency Max. Motor current Speed Power Capacitor Weight m³/min. Pa. V. Hz. Amp. o/min. kw. µf/v Kg. D03M 3,2 330 D03M 3, / / ,36-0,68/ 0,21-0,36 0,33-0,55/ 0,19-0, ,03-4, ,05-4,2 E03 3, , ,03 3/450 3,9 E03 3, , ,05 3/450 3,9 50 HZ 60 HZ 4

5 D04M, E04 S484 version total length 239,5 mm. Max. Max. Voltage Frequency Max. Speed Power Capacitor Weight m³/min. Pa. V. Hz. Amp. o/min. kw. µf/v Kg. D04M 5,0 350 D04M 6, / / ,45-0,72/ 0,26-0,42 0,47-0,52/ 0,27-0, ,07-4, ,12-4,5 E04 5, , ,07 3/450 4,7 E04 6, , ,12 3/450 4,7 5

6 D045M, E045 S484 version total length 263 mm. Max. Max. Voltage Frequency Max. Speed Power Capacitor Weight m³/min. Pa. V. Hz. Amp. o/min. kw. µf/v Kg. D045M 7, / ,50/0, ,10-4,7 D045M 9, / ,66/0, ,17-4,7 E045 7, , ,10 3/450 4,9 E045 9, , ,17 3/450 4,9 6

7 D05M, E05 S484 version total length 266 mm. Max. Max. Voltage Frequency Max. Speed Power Capacitor Weight m³/min. Pa. V. Hz. Amp. o/min. kw. µf/v Kg. D05M 10, / ,59/0, ,13-5,0 D05M 11, / ,74/0, ,19-5,0 E05 10, , ,14 3/450 5,2 E05 9, , ,14 3/450 5,2 7

8 D052M, E052 S484 version total length 371 mm. Max. Airflow Max. Pressure Voltage Frequency Max. Speed Power Capacitor Weight m³/min. Pa. V. Hz. Amp. o/min. kw. µf/v Kg. D052M 15,0 530 D052M 18, / / ,25-2,15/ 0,72-1,24 1,73-1,91/ 1,00-1, ,37-7, ,44-7,6 E052 13, , ,37 10/450 6,4 E052 12, , ,44 8/450 6,4 8

9 D060, E060 S484 version total length 387 mm. Max. Max. Voltage Frequency Max. Speed Power Capacitor Weight m³/min. Pa. V. Hz. Amp. o/min. kw. µf/v Kg. D060 22, ,50-1, ,55-12,0 D060 24, ,55-2, ,90-12,0 E060 22, , ,55 16/450 11,0 E060 22, , ,75 16/450 11,0 9

10 D064, E064 S484 version total length 403 mm. Max. Max. Voltage Frequency Max. Speed Power Capacitor Weight m³/min. Pa. V. Hz. Amp. o/min. kw. µf/v Kg. D ,00-2, ,10-15,0 D ,45-2, ,32-15,0 E , ,10 30/450 17,0 E , ,10 30/450 17,0 10

11 D066, E066 S484 version total length 443 mm. Max. Max. Voltage Frequency Max. Speed Power Capacitor Weight m³/min. Pa. V. Hz. Amp. o/min. kw. µf/v Kg. D / ,55/3, ,5-19,0 D / ,45/3, ,8-19,0 E , ,5 30/450 18,0 E , ,5 30/450 18,0 11

12 D07, D072 S484 version total length + 28 mm. Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. D / ,50/4, ,20 25 D / ,20/5, ,65 25 D / ,4/6, ,00 27 D / ,6/7, ,

13 D08, D082 S484 version total length + 28 mm. Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. D / ,50/4, ,2 30 D / ,20/5, ,6 30 D / ,4/6, ,0 33 D / ,6/7, ,

14 D09, D092 S484 version total length + 28 mm. Motor A D SX 605 D SL 640 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. D , ,5 66 D , ,6 66 D , ,5 71 D , ,

15 Blowers in twin models. A number of low pressure blowers can be supplied in a twin version, called 2D version. All the characteristics of these blowers are equal to the low-pressure blowers. The motor is placed in the center and has additional cooling fins because the cooling fan is missing and is over dimensioned. The advantage is that you can connect two pipes separately or if it is necessary parallel linking, while only one arrangement is required. 15

16 2D04 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. 2D / ,04/0, ,14 6,7 2D / ,13/0, ,24 6,7 16

17 2D045 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. 2D / ,63/0, ,24 8,7 2D / ,73/1, ,30 8,7 17

18 2D05 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. 2D / ,90/1, ,35 8,4 2D / ,15/1, ,55 8,4 18

19 2D052 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. 2D / ,6/1, ,56 11,0 2D / ,6/1, ,70 11,0 19

20 2D060 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. 2D / ,55/3, ,5 19 2D / ,45/3, ,

21 2D064 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. 2D / ,50/4, ,2 25 2D / ,20/5, ,

22 2D066 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. 2D , ,0 39 2D , ,

23 2D07 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. 2D , ,0 50 2D , ,

24 2D08 Max. Max. Voltage Frequency Max. Speed Power Weight m³/min. Pa. V. Hz. Amp. o/min. kw. Kg. 2D , ,0 52 2D , ,

25 ACCESSORIES Control valve. Is mounted on the pressure side. Blow nozzle. Suction nozzle a b d e f h Article nr. D03, E D04, E04, 2D04 D045, E045, 2D045 D05, E05, 2D05 D052, E052, 2D052 D060, E060, 2D060 D064, E064, 2D064 D066, E066, 2D D07, D072, 2D D08, D082, 2D D09,D a b d1 d2 d3 e f h1 h2 Article nr. D03, E D04, E04, 2D D045, E045, 2D D05, E05, 2D D052, E052, 2D D060, E060, 2D D064, E064, 2D D066, E066, 2D D07, D072, 2D D08, D082, 2D D09, D d1 d2 d3 d4 d5 h1 h2 Articl nr. D03, E ,5 4x5, D04, E04, 2D ,5 4x5, D045, E045, 2D x D05, E05, 2D ,5 4x5, D052, E052, 2D x5, D060, E060, 2D x5, D064, E064, 2D ,5 4x5, D066, E066, 2D x D07, D072, 2D x D08, D082, 2D x D09, D x bosaventilatoren bv 25

26 Fine dust filter. Is mounted on the suction side. d1 d2 d3 d5 e h1 h2 Article nr. D03, E x D04, E04, 2D x D045, E045, 2D x D05, E05, 2D x D052, E052, 2D x D060, E060, 2D x5, D064, E064, 2D x D066, E066, 2D x D07, D072, 2D x D08, D082, 2D x D09, D x Att:. Dirty filters reduce greatly the blower capacity. Regularly check the filter! Replace filter matting. For fine dust filter. Blower Article nr. D03, E03 15x120x D04, E04, 2D04 15x120x D045, E045, 2D045 15x160x D05, E05, 2D05 15x225x D052, E052, 2D052 15x225x D060, E060, 2D060 15x250x D064, E064, 2D064 15x355x D066, E066, 2D066 15x460x D07, D072, 2D07 15x460x D08, D082, 2D08 15x460x D09, D092 15x665x bosaventilatoren bv 26

RADIAL ALUMINUM LOW PRESSURE

RADIAL ALUMINUM LOW PRESSURE RADIAL ALUMINUM LOW PRESSURE Content: LOW PRESSURE BLOWERS... 2 GENERAL... 3 D03M, E03... 4 D04M, E04... 5 D05M, E05... 6 D052M, E052... 7 D060, E060... 8 D064, E064... 9 D066, E066... 10 D07, D072...

More information

RADIAL ALUMINUM HIGH PRESSURE

RADIAL ALUMINUM HIGH PRESSURE RADIAL ALUMINUM HIGH PRESSURE Content HIGH PRESSURE BLOWERS... 2 GENERAL... 3 PRESELECTED HIGH PRESSURE SERIES... 4 HRD 1/2T... 5 HRD 1/3 T... 6 HRD 1/4 T... 7 HRD 1/5 T... 8 HRD 14/5 T... 9 HRD 2/3 T...

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200 Defining Innovation. turbo pressure blowers MODEL TBA TBR 1 Twin City Catalog CATALOG -A May 11 Model TBA/TBR Turbo Pressure Blowers Model TBA and TBR fans from Twin City Fan & Blower are constant pressure,

More information

TURBO PRESSURE BLOWERS

TURBO PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBA TBR CATALOG 10 APRIL 13 TURBO PRESSURE BLOWERS Models TBA TBR TBR Arrangement 8 Model TBA and TBR fans from

More information

SIDE CHANNEL BLOWERS

SIDE CHANNEL BLOWERS SIDE CHANNEL BLOWERS RT-1 / RT-2 / RT-3 / RT-4 series 23 RT-4 / RT-5 / RT-6 / RT-7 / RT-8 / RT-9 series 24 RT-23 / RT-33 / RT-43 / RT-63 / RT-83 series 25 19 Applications Aeration Swiing pools and whirlpools

More information

RADIAL STEEL HIGH PRESSURE RHD 5/ RHD 4/ RHD 8/ RHD 11/ RHD 9/ RHD 13/ CAS... 8 CAM ACCESSORIES...

RADIAL STEEL HIGH PRESSURE RHD 5/ RHD 4/ RHD 8/ RHD 11/ RHD 9/ RHD 13/ CAS... 8 CAM ACCESSORIES... RADIAL STEEL HIGH PRESSURE RHD 5/10... 2 RHD 4/20... 3 RHD 8/25... 4 RHD 11/40... 5 RHD 9/60... 6 RHD 13/90... 7 CAS... 8... 14 ACCESSORIES... 18 1 RHD 5/10 A 230 / B 335 / C 385 / D 130 / E 140 / F 360

More information

Side Channel Blowers & Turboblowers

Side Channel Blowers & Turboblowers 1406 Side Channel Blowers & Turboblowers ENGINEERING & TRADING COMPANY Phone +45 4386 8333. Fax +45 4386 8388. e-mail: klee@klee.dk. www.klee.dk Index Side Channel Blowers Characteristics page 5 Application

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

[Small diaphragm vacuum pumps]

[Small diaphragm vacuum pumps] [Small diaphragm vacuum ] The small vacuum shown on this page produce vacuum using a diaphragm. They can be used either as vacuum pump or as a small compressor, and they are able to deliver 100% oil-free

More information

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas! Page 1 Standard Series Size: 3 Air flow volume Calculation of external available Pressure [m³/h] 3 4 5 55 6 65 7 75 8 9 1 11 12 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc.

More information

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION READ AND SAVE THESE INSTRUCTIONS Vertical Air Flow Mist Precipitator Industrial Applications TRION Vertical Air Flow Mist Precipitator for Industrial Applications Table of Contents Design...2 Installation...2

More information

Company Introduction Construction & Specific Parts and Illustration Appliation For Blowing Application for Suction...

Company Introduction Construction & Specific Parts and Illustration Appliation For Blowing Application for Suction... -Page1- Content Company Introduction... 4 Construction & Specific... 5 Parts and Illustration... 6 Appliation For Blowing... 8 Application for Suction... 9 Single Phase AC IP55 50Hz/60Hz... 10 Three Phase

More information

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 June 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated

More information

DWO DWO DWO DWO

DWO DWO DWO DWO Model Contents Item No. Specifications Selection Performance Pump Sectional Motor Chart Curve Dimensions View Data 506 704 006 70 70 705 708 709 7 006 706 4006 707 www.pumpsebara.com 700 (t) 80 7-5005

More information

FAN & BLOWER CENTRIFUGAL FANS

FAN & BLOWER CENTRIFUGAL FANS FAN & BLOWR CNTRIFUGAL FANS INTRODUCTION GNRAL PRODUCT RANG FANS BY FANTCH - INTRACTIV PRODUCT SUIT SLCTION PROGRAM PRFORMANC CONSTRUCTION The Fan & Blower range of centrifugal fans is marketed to the

More information

COMMERCIAL DUTY PLENUM FANS

COMMERCIAL DUTY PLENUM FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 JUNE 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed

More information

About Vacuum Producers

About Vacuum Producers Vacuum Producers About Vacuum Producers The heart of the system The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system. In Dustcontrol extraction systems,

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

D-Series Blowers and Exhausters

D-Series Blowers and Exhausters Operation and Maintenance Manual D-Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 MONOXVENT BLOWERS AND EXHAUSTERS D05-1 D05-3 D10-1 D10-3 D15-1 D15-3 D20-1 D20-3 D30-1 D30-3 ½ HP TEFC

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

Unobox units with backward curved centrifugal impellers

Unobox units with backward curved centrifugal impellers Unobox Fans Unobox units with backward curved centrifugal impellers Type Code UNO 67-450 -4 E W Unobox Box size 50=500mm ; 67=670mm 80=800mm ; 102=1020mm Impeller diameter Number of poles D - Three Phase

More information

User s Manual D-Series Blowers and Exhausters

User s Manual D-Series Blowers and Exhausters User s Manual D-Series Blowers and Exhausters D05-1 ½ HP TEFC 115/230 VOLTS, 1 PH D05-3 ½ HP TEFC 208/230/460 VOLTS, 3 PH D10-1 1 HP TEFC 115/230 VOLTS, 1 PH D10-3 1 HP TEFC 208/230/460 VOLTS, 3 PH D15-1

More information

Performance Data. Fan Performance Curves - FDCLP2 with ECM. Unit Size Unit Size FDCLP2 Fan Curves-1 v001

Performance Data. Fan Performance Curves - FDCLP2 with ECM. Unit Size Unit Size FDCLP2 Fan Curves-1 v001 Fan Performance Curves - FDCLP2 with ECM Unit Size 1 1 2 3 4 5 6 7 8 9 1 11 Unit Size 2 1 2 3 4 5 6 7 8 9 1 11 12 No Coil 1 Row 2 Row FDCLP2 Fan Curves-1 v1 Fan Performance Curves - FDCLP2 with ECM Unit

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Vacuum Producers. The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system.

Vacuum Producers. The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system. Vacuum Producers The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system. 23 About Vacuum Producers The heart of the system The vacuum producer is the

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

HALLMARK INDUSTRIES INC.

HALLMARK INDUSTRIES INC. 4 Deep Well Submersible Pump Part # Power Flow M 3 /H 0 1 2 2.6 3.2 3.6 4.2 4.5 Weight HP Volt Amp Flow (GPM) 0 4.6 9.1 11.5 14 16 18.4 20 (lbs) MA0343X-4 1/2 115 6.5 Head (ft) 154 142 120 103 80 56 27

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

Side channel blowers

Side channel blowers 19 Side channel blowers 20 Characteristics Quiet Equipped with low-noise, high-efficiency IP54 induction motor and specially designed mufflers, all blower series feature quiet operation. Type number Types

More information

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GENERAL VENTILATOR A quality product suitable for general residential application. proprietary made and compact design fan is designed

More information

CVM. EBARA PUMPS EUROPE S.p.A. MULTISTAGE CENTRIFUGAL PUMPS

CVM. EBARA PUMPS EUROPE S.p.A. MULTISTAGE CENTRIFUGAL PUMPS CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE A (UP TO 0.6 kw) 203 PERFORMANCE CURVE A (FROM 0.75 kw UP TO 1.1 kw) 204 PERFORMANCE CURVE

More information

- SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART MULTIGO PERFORMANCE CHART MULTIGO

- SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART MULTIGO PERFORMANCE CHART MULTIGO CONTENTS Page - CONTENTS CONTENTS 100 - SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 40 202 PERFORMANCE CHART 80 203 - CONSTRUCTIONS CONSTRUCTIONS 300 CONSTRUCTIONS 301 CONSTRUCTIONS

More information

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7 Calculation of external available Pressure Page 1 Size: 1 Air flow volume [m³/h] 4 6 8 1 12 14 16 18 2 24 28 32 36 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc. to white

More information

AXIAL FLOW CABINET FAN CGT Series

AXIAL FLOW CABINET FAN CGT Series Range of adjustable pitch aerofoil blade, axial flow cabinet fans. Fan casing manufactured from heavy gauge galvanised sheet steel internally lined with 25 mm thickness fireproof fibreglass acoustic insulation

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 PERFORMANCE CHART A (up to 0.6 kw) 203 PERFORMANCE CHART A (from 0.75 kw up to 1.1 kw) 204 PERFORMANCE CHART A (1.3 kw) 205 PERFORMANCE

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

Vacuum Producers. Vacuum Producers

Vacuum Producers. Vacuum Producers Vacuum roducers Vacuum roducers 7 Vacuum roducers About Vacuum roducers The heart of the system The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system.

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203

Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART 202 PERFORMANCE CHART VOX 203 - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 DIAGRAM AND ELECTRIC CONNECTIONS 302 DIAGRAM

More information

APIFLO-M series Series

APIFLO-M series Series APIFLO-M series Series Horizontal Multistage Pump According to API610 Capacity: up to 650m 3 /h (50Hz) up to 780 m 3 /h (60Hz) Head: up to 1200m (50Hz) up to 1728 m (60Hz) Pressure: APIFLO-M: up to 25

More information

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL Fan Powered Terminals VAV TERMINALS IOM FAN POWERED TERMINALS Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage is

More information

CA3000C & CA6000C Cartridge Air Cleaners

CA3000C & CA6000C Cartridge Air Cleaners CA3C & CA6C Cartridge Air Cleaners A i r P u r i f i c a t i o n S y s te m s w w w. t r i o n i a q. c o m Clean Air Solutions Designed for high efficiency, self-cleaning, easy serviceability, and long

More information

Airscrew 200+ Vmax Vaneaxial Fans

Airscrew 200+ Vmax Vaneaxial Fans Airscrew + Vmax Vaneaxial Fans General Vaneaxial Information Vmax Vaneaxial Fans comprise a combination of rotating impeller and stationary guide vanes, housed within an axial duct known as the fan case.

More information

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL AND BEARINGS 302 MECHANICAL SEAL 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL AND BEARINGS 302 MECHANICAL SEAL 303 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE A (UP TO 0.6 KW) 204 PERFORMANCE CURVE A (FROM 0.75 KW UP TO 1.1 KW) 205 PERFORMANCE CURVE

More information

CRS 2500 TECHNICAL GUIDE

CRS 2500 TECHNICAL GUIDE CRS2500 TECHNICAL GUIDE Model # CRS-2500 220v 1PH, 50/60 HZ Description CRS2500IDECcoolersaredesignedforoutdoorinstallation.Onlyutilityandductconnectionsarerequiredatthe pointofinstallation. FieldinstalledThermostatisrequired(Singlephaseonly)

More information

2CDU70/206-2HP 2CDU70/306-3HP CDU120/306-3HP 2CDU200/506-5HP 607

2CDU70/206-2HP 2CDU70/306-3HP CDU120/306-3HP 2CDU200/506-5HP 607 Model CDX/CDU Contents CDX/CDU Item No. Specifications Selection Performance Pump Sectional Motor Chart Curve Dimensions View Data CDXU70/06-HP CDXU70/6-HP 5 6 8 6 CDXU0/6-HP CDXU00/6-5HP 7 CDU70/06-HP

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 203 PERFORMANCE CURVE 120 204 PERFORMANCE CURVE 200 205 - CONSTRUCTIONS 300 SECTIONAL VIEW

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL AND BEARINGS 302 MECHANICAL SEAL 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL AND BEARINGS 302 MECHANICAL SEAL 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE A (UP TO 0.6 KW) 204 PERFORMANCE CURVE A (FROM 0.75 KW UP TO 1.1 KW)

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

Technical Service Manual

Technical Service Manual Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........

More information

Horizontal Cartridge DUST COLLECTOR OPF

Horizontal Cartridge DUST COLLECTOR OPF * The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces.

More information

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels KAT DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels KAT Series DOUBLE INLET ENTRIFUGAL FAN with Forward Wheels Kruger Ventilation Industries certifies that the KAT series : version S and - model 9-7 to

More information

Technical Data. 400 Series 403D-15G. ElectropaK

Technical Data. 400 Series 403D-15G. ElectropaK Technical Data 400 Series 403D-15G ElectropaK Basic technical data Number of cylinders.................................................... 3 Cylinder arrangement.................................... Vertical

More information

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning

LPS IN-LINE CENTRIFUGAL ELECTRIC PUMPS. Your Life, our Quality. Worldwide. 118 Heating & Conditioning In-Line centrifugal electric pumps with stainless steel hydraulic parts AISI 304. APPLICATIONS Civil/industrial heating plants Systems for moving domestic hot water Cooling and air conditioning plants

More information

AC axial fans S series, Ø 500

AC axial fans S series, Ø 500 axial fans, Ø 500 Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic lades: Sheet aluminium Rotor: ncased in aluminium

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL

More information

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page SPECIFICATIONS 0 SELECTION CHART 1 TYPE KEY 3 PERFORMANCE CURVE SPECIFICATIONS 4 MEI INDEX SPECIFICATIONS 5 PERFORMANCE CURVE 32 6 PERFORMANCE CURVE 32 7 PERFORMANCE CURVE 320 8 PERFORMANCE

More information

SINGLE STAGE TWO STAGES

SINGLE STAGE TWO STAGES BLOWERS CATALOG Table of contents SINGLE STAGE TWO STAGES 3 4 1 1 5 6 7 8 9 10 11 12 Weight (Kg) 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 2RSC 50-65 Performance curve for Vacuum

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 QUANTITY FOR MODEL 303 BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 QUANTITY FOR MODEL 303 BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATION 202 PERFORMANCE CURVE 40/86 203 PERFORMANCE CURVE 40/106 204 PERFORMANCE CURVE 40/126 205 PERFORMANCE CURVE 40/156

More information

NH 3. Evaporator. Ammonia Applications Tons MANP

NH 3. Evaporator. Ammonia Applications Tons MANP NH 3 Evaporator Ammonia Applications 12-108 Tons > > Used for medium TO large Industrial Ammonia applications Manufactured with Stainless steel tubes. The Global Leader In Heat Exchange Technology With

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel ITEC High Efficiency EC Twin Fan for convenient fitting and full control Casing constructed from 1.6mm Galvanised sheet steel Circular spigot connection Inline for ease of fitting into duct system Single

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

BWW EXHIBITION Sharing of experience. Kuek Eng Mong. Group Engineers Malaysia Sdn Bhd

BWW EXHIBITION Sharing of experience. Kuek Eng Mong. Group Engineers Malaysia Sdn Bhd BWW EXHIBITION 2012 Sharing of experience Kuek Eng Mong Group Engineers Malaysia Sdn Bhd CASE 1 DO NOT OVER ESTIMATE SYSTEM HEAD FOR PUMP SELECTION Use Reasonable C value. Hf 6.78xL( m) V ( m / s) 1.165

More information

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX DIMENSION TABLE MATRIX PACKING 403

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX DIMENSION TABLE MATRIX PACKING 403 CONTENTS Page - SPECIFICATIONS 200-201 SELECTION CHART 202 SELECTION CHART TABLE 203 TYPE KEY AND CURVE SPECIFICATIONS 204 PERFORMANCE CURVE 3 ( 2-3-4-5 IMPELLERS ) 205 PERFORMANCE CURVE 3 ( 6-7-8-9 IMPELLERS

More information

WELDING FUME EXHAUSTERS & ARMS

WELDING FUME EXHAUSTERS & ARMS WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through

More information

FCX TECHNICAL BOOKLET

FCX TECHNICAL BOOKLET FAN COIL FCX US FCX USPO This document is based on AERMEC s FCX US, USP, USPO Technical and Installa on Booklet but reflects only those sizes and configura ons currently offered by Phoenix Energy Supply.

More information

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572 FEATURES Computer designed, efficient performance, forward curved blower. Blower wheel hub is secured to the shaft with a locking keyway. Blower is secured to anti-vibration mounts within the cabinet.

More information

NCF fans 50 Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices Aerofoil Ventilation Fans Quality & Performance at Affordable Prices GENERAL FEATURES, located in Chennai strives to deliver quality products at affordable costs to all its customers. Our company s vision

More information

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

AGA-AGC. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

AGA-AGC. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE AGA 0.60 203 PERFORMANCE CURVE AGA 0.75 204 PERFORMANCE CURVE AGA 1.00 205 PERFORMANCE CURVE

More information

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans. 4 AC Fans AC Fans Overview 7 AC Axial Fans 8 AC Radial Fans 38 AC Radial Fans AC Axial Fans AC Fans ACmaxx Axial Fans Technology DC Axial Fans Specials DC Radial Fans 5 Accessories AC Fans Technical Informations

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,

More information

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017 Position Qty. Description 1 NB 1-31/29 A-F2-B-E-BAQE Phone: 4 84 61 Date: 13/3/217 Product No.: On request Non-self-priming, single-stage, centrifugal volute pump designed according to ISO 199 with dimensions

More information

CM15-1 A-R-I-V-AQQV C-A-A-N

CM15-1 A-R-I-V-AQQV C-A-A-N GRUNDFOS DATA BOOKLET CM15-1 A-R-I-V-AQQV C-A-A-N Grundfos Pump 97515 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/97515/cm15-1-a-r-i-v-aqqv.html

More information

Engineering Data Book

Engineering Data Book 40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

WINDER. Impellers with higher efficiency and less sound level

WINDER. Impellers with higher efficiency and less sound level WINDER Impellers with higher efficiency and less sound level Winder Solutions The last new generation impeller With the Serrated Novovent Concept (S.N.C.), NOVOVENT, S.A. has developed a new blades generation.

More information

Airscrew 105 to 170 Vmax Vaneaxial Fans

Airscrew 105 to 170 Vmax Vaneaxial Fans Airscrew 5 to 17 Vmax Vaneaxial Fans General Vaneaxial Information Vmax Vaneaxial Fans comprise a combination of rotating impeller and stationary guide vanes, housed within an axial duct known as the fan

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

DPS. The SSV Dual Pump System

DPS. The SSV Dual Pump System DPS The SSV Dual Pump System A Full Range of Product Features The DPS series of 36L stainless steel vertical multi-stage pumps from G&L has been designed to provide reliable high pressure boosting to serve

More information

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package.

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package. 5H Z VERSION Experts in Spray Technology Spray Nozzles Spray Control Spray Analysis Spray Fabrication WindJet Air Knife Packages Deliver superior blowing and drying performance in a complete, customizable

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

DC Dual Inlet Centrifugal Blowers

DC Dual Inlet Centrifugal Blowers DC Dual Inlet Centrifugal Blowers 85 to 656 CFM Brushless DC Dual Inlet Centrifugal Blowers.5..9.6 4 6 8 35 3 5 5.3 3 5 3 4 5 6 Curve Ref. Rota- CFM Wgt. Temp. Number Part Number Volts Watts Flange tion*

More information

Technical brochure. LTG Fans. Tangential fans Type GA 25 / TA 40. Impeller diameter 25 mm / 40 mm.

Technical brochure. LTG Fans. Tangential fans Type GA 25 / TA 40. Impeller diameter 25 mm / 40 mm. Technical brochure LTG Fans Tangential fans Type GA 25 / TA 40 Impeller diameter 25 mm / 40 mm www.ltg.net LTG Process Air Technology LTG Fans LTG Filtration Technology LTG Humidification Technology Content

More information

VERTICAL IN-LINE PUMP

VERTICAL IN-LINE PUMP VERTICAL IN-LINE PUMP TECHNICAL FEATURES ELINE: Vertical centrifugal pumps, single impeller, volute casing, non-self priming pump, in-line executive, with mechanical seal. Hydraulically designed in line

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and