HEPA terminal filter units Ceiling diffusers: F640, F650, F654, F655, F656, F659, F660 Wall grilles: F670

Size: px
Start display at page:

Download "HEPA terminal filter units Ceiling diffusers: F640, F650, F654, F655, F656, F659, F660 Wall grilles: F670"

Transcription

1 HPA terminal filter units eiling diffusers: 60, 650, 65, 655, 656, 659, 660 Wall grilles: 670 or critical air purity and hygiene requirements Used in medicine, biology, pharmaceuticals, and sensitive technical areas onstructions with shut-off damper or volume flow controller ontent overview eneral information... ace plates Special information... eiling diffuser eiling diffuser eiling diffuser eiling diffuser eiling diffuser eiling diffuser eiling diffuser Wall grille Specification text eaflet 6 / 1 / 2 / N

2 eneral information etail Application HPA terminal filter units for ceiling and wall installation as final filters (last filter stage) and for air distribution. itting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses, and bacteria from the supply and extract air. aterial asing made of sheet steel with powder coating (RA 9010). Available in stainless steel upon request. onstruction -Type 60: With side entry circular spigot -Type 650: With side entry rectangular spigot -Type 65: With manually adjustable shutoff damper and side entry circular spigot -Type 655: With shut-off damper, with pneumatic actuator and side entry circular spigot -Type 655: With shut-off damper, with pneumatic actuator and side entry circular spigot -Type 656: With shut-off damper, with electric actuator and side entry circular spigot -Type 659: With volume flow limiter and side entry circular spigot -Type 660: With top circular entry spigot -Type 670: Wall grille quipment - asing with clamping mechanism (two-point fixing) for the HPA filter. - Sealing integrity test facility and pressure measuring points to monitor differential operating pressure. - iffuser face plate for ceiling applications: Types Q-A,, VW, and Q made of sheet steel with powder coating (RA 9010). Type AQ-A made of anodised aluminium profiles. - rille face plate for wall application: Type S-A made of sheet steel with powder coating (RA 9010). Type AS-A made of anodised aluminium profiles. Options - lamping mechanism for the minipleat filter panel as four-point fixing. - Side suspension points and locations of differential pressure measurement points. - Sealing integrity test facility and internal measuring tube. Associated TROX filter elements Associated filters to be ordered separately. Installation and maintenance iffuser face plate with central fixing to facilitate its removal for filter change and decontamination. Suitable filter elements inipleat filter panels used as HPA filters (7/9/../..) - High-performance filters for the most critical requirements of air purity and sterility - Type 780 (11), Type 781 (H13), Type 782 (H1). -onstruction: rame made of, galvanised sheet steel, or stainless steel with flat section seal; frame made of extruded aluminium profiles with flat section seal or fluid seal. 2 HPA terminal filter units - eaflet 6/1/2/N

3 ace plates etail ace plates - iffuser face plate for ceiling applications: Types Q-A,, VW, and Q made of sheet steel with powder coating (RA 9010). Type AQ-A made of anodised aluminium profiles. - rille face plate for wall application: Type S-A made of sheet steel with powder coating (RA 9010). Type AS-A made of anodised aluminium profiles. onfiguration and code letters iffuser face plate Type ode letter 2 iffuser face Type ode letter 2 plate AQ-A Q-A A S VW VW 625 x 8 VW 680 x 5 V Other types of diffuser face plate and filter cell constructions available upon request. Table 1: iffuser face plates for ceiling application Q Table 2: iffuser face plates for ceiling application Possible combinations of unit size and diffuser face plate The diffuser face plates are a part of the unit and must be included in the purchase order. rille face plates for wall applications, see page 1. Type AQ-A/Q-A AQ-A/Q-A AQ-A/Q-A AQ-A/Q-A AQ-A/Q-A VW 00 x 16 VW 500 x 2 VW 600 x 2 VW 625 x 2 VW 680 x 2 VW 625 x 8 VW 680 x 5 Q Q Q Q Q Unit size /N P/Q / / / /N P/Q / / / /N P/Q / / / / / /N P/Q / / / iffuser face plate imensions in Size iffuser face plate ax. 1) volume flow rate m 3 /h urther information lima 1-2/11/0/ lima 1-2/11/0/ lima 1-2/11/0/ lima 1-2/11/0/ lima 1-2/11/0/ lima 1-2/6/0/ lima 1-2/6/0/ lima 1-2/6/0/ lima 1-2/6/0/ lima 1-2/6/0/ lima 1-2/7/0/ lima 1-2/7/0/ lima 1-2/7/0/ lima 1-2/7/0/ lima 1-2/7/0/ lima 1-2/7/0/ lima 1-2/7/0/ lima 1-2/15/0/ lima 1-2/15/0/ lima 1-2/15/0/ lima 1-2/15/0/ lima 1-2/15/0/ ode letter 2 A/S A/S A/S A/S A/S V V V V V Table 3: Volume flow rates for the ceiling diffusers 1) Volume flow rate at 0 db (A) HPA terminal filter units - eaflet 6/1/2/N 3

4 10 Unit type: Type 60 (last number = spigot code number) Type 650 Type 65 Type 655 Type 656 Type 659 Type 660 (last number = spigot code number) Type 670 or the diffuser face plate, see pages 3 and 1: A=AQ-A (ceiling diffuser), AS-A (wall grille) S=Q-A (ceiling diffuser), S-A (wall grille) = V=VW = VW 625 x 8 = VW 680 x 5 =Q Sealing integrity test facility: 1 = Sealing integrity test facility (standard) 2 = Sealing integrity test facility and internal measuring tube 1) Unit size: See the technical data in Tables to 1. Number of fixing points: 0 = 2 fixing points (standard) = fixing points 1) aterial of casing: 0 = Sheet steel, powder-coated in RA 9010 (standard) S = Sheet steel, powder-coated in RA 9005 = Stainless steel, pickled lange width: 0 = lange width (standard) = lange width, limiting size ) Zero Suspension and measuring points: 1) 0 = Top (standard) S=Side Zeros 1) Options only available for ceiling-mounted HPA filter units. xample: Type 68 with spigot code number eiling-mounted HPA filter Type 60 with spigot diameter of 28 with spigot code number 8: 68 iffuser face plate Type : Sealing integrity test facility and internal measuring tube: 2 Unit size: 575 x 575 x 78 : Two-point fixing: 0 asing made of sheet steel, powder-coated in RA 9010 (standard): 0 lange width (standard): 0 Side suspension and measuring points: S xample: Type 65 without spigot code number eiling-mounted HPA filter Type 65: 65 iffuser face plate Type VW: V Sealing integrity test facility and internal measuring tube: 2 Unit size: 575 x 575 x 78 : our-point fixing: asing made of sheet steel, powder-coated in RA 9010 (standard): 0 lange width (standard): 0 Side suspension and measuring points: S S V S 0 0 HPA terminal filter units - eaflet 6/1/2/N

5 Special information Sealing integrity test facility and measuring tube Test groove ilter seal onnection for sealing integrity test facility easuring tube ø 8 x 1.5 heesehead screw 6 x 10 etail drawing 1: Sealing integrity test facility etail drawing 2: Internal measuring tube Suspension and measuring points S Suspension easuring point on upstream side (plus) easuring point on downstream side (minus) Suspension easuring point on upstream side (plus) easuring point on downstream side (minus) etail drawing 3: Top suspension and measuring points etail drawing : Side suspension and measuring points HPA terminal filter units - eaflet 6/1/2/N 5

6 eiling diffuser 60 1 eiling diffuser Type 60 X S U 0 etail drawing 5: 60 with side entry circular spigot etail drawing 6: etail X Seal etail drawing 7: minipleat filter panels with flat section seal etail drawing 8: minipleat filter panels with fluid seal 6 HPA terminal filter units - eaflet 6/1/2/N

7 eiling diffuser 60 imensions of 60 and filter element size 6 6 A 1 A Unit size N N P P Q Q ilter element size B H T 1) / / / / Nominal volume flow rate 2) l/s m³/h imensions in U S Weight Spigot code no. Approx. (last digit kg of 1 ) 17 1, 3 17, , 3 17, , , Table : for 60 1) inipleat filter panel with flat section seal / minipleat filter panel with fluid seal 2) Related to minipleat filter panel 781 in the specified filter size Spigot dimensions Ø Spigot code number (last digit of 1) Table 5: Spigot dimensions and code numbers ist of abbreviations A = Overall width of rectangular inlet spigot flange 650 = iameter of entry spigot = Overall dimension of case including entry spigot 650 = ace flange width = imensions from face flange to centerline of spigot 1 = asing height = Overall dimensions of flange = Overall dimensions of diffuser face plate N = Overall length of grille face plate (Type 670) = Top suspension distance between holes = Overall dimensions of casing S = istance from casing flange to damper operator cover U = asing extension HPA terminal filter units - eaflet 6/1/2/N 7

8 eiling diffuser 650 A eiling diffuser Type 650 X etail drawing 9: 650 with side entry rectangular spigot etail drawing 10: etail X imensions of 650 and filter element size Unit size N P Q ilter element size B H T 1) / / l/s Table 6: for 650 Nominal volume flow rate 2) m³/h ) inipleat filter panel with flat section seal / minipleat filter panel with fluid seal 2) Related to minipleat filter panel 781 in the specified filter size imensions in A Weight Approx. kg HPA terminal filter units - eaflet 6/1/2/N

9 eiling diffuser 65 etail onstruction Air-tight shut-off damper according to IN N 1751, lass (nominal size 125, lass 3) for use in ventilation systems with critical hygiene requirements. Installation and maintenance ue to the integral shut-off damper, filter change and maintenance work is possible without disturbance to the system operation. With additional manually adjustable shut-off damper, sealing integrity test facility, and internal pressure measuring point. eiling diffuser Type S 1 X etail drawing 11: 65 with side entry circular spigot etail drawing 12: etail X imensions of 65 and filter element size Unit size P ilter element size B H T 1) / /91 Nominal volume flow rate 2) l/s m³/h imensions in Ø 1 S Weight Approx. kg Table 7: for 65 1) inipleat filter panel with flat section seal / minipleat filter panel with fluid seal 2) Related to minipleat filter panel 781 in the specified filter size HPA terminal filter units - eaflet 6/1/2/N 9

10 eiling diffuser 655 etail eiling diffuser Type 655 onstruction Air-tight, automatic shut-off damper according to IN 196 Part with pneumatic actuator (fail safe closed). This guarantees that in the case of loss of control pressure the room is isolated. eiling diffuser with internal pressure measuring point. Installation and maintenance ilter change and maintenance work is possible without interruption of the system operation; access to the actuator without having to open the ceiling. Pneumatic actuator - ontrol pressure: 0.6 to max. 1.0 bar. -ompressed air connection: push-on fitting for PT hose 6 x U X etail drawing 13: 655 with side entry circular spigot U = 89 ; only for unit size for filter size 35 x 35 etail drawing 1: etail X imensions of 655 and filter element size Unit size P ilter element size B H T 1) / /91 Nominal volume flow rate 2) l/s m³/h imensions in Ø Weight Approx. kg Table 8: for 655 1) inipleat filter panel with flat section seal / minipleat filter panel with fluid seal 2) Related to minipleat filter panel 781 in the specified filter size 10 HPA terminal filter units - eaflet 6/1/2/N

11 eiling diffuser 656 etail onstruction As Type 655, with electric actuator for the shut-off damper (fail safe closed). lectric actuator - ains connection: 230 V, 50 Hz. - Power consumption: Approx. 10 W. - Supply wiring: 2 x 0.75 ². eiling diffuser Type U X etail drawing 15: 656 with side entry circular spigot U = 89 ; only for unit size for filter size 35 x 35 etail drawing 16: etail X imensions of 656 and filter element size A 1 Unit size P ilter element size B H T 1) / /91 Nominal volume flow rate 2) l/s m³/h imensions in Ø Weight Approx. kg Table 9: for 656 1) inipleat filter panel with flat section seal / minipleat filter panel with fluid seal 2) Related to minipleat filter panel 781 in the specified filter size HPA terminal filter units - eaflet 6/1/2/N 11

12 eiling diffuser 659 etail onstruction With integral volume flow limiter Type V made of high-quality plastic for the limitation and control of constant volume flow rates. Type V volume flow limiter The volume flow limiter is set to a reference volume flow rate at the factory and can be readjusted within a volume flow rate range of > 5:1. or more information regarding the volume flow limiter, see the separate V eaflet. eiling diffuser Type Ø X etail drawing 17: 659 with side entry circular spigot etail drawing 18: etail X imensions of 659 and filter element size Unit size P ilter element size B H T 1) / /91 Nominal volume flow rate 2) l/s m³/h imensions in Ø Weight Approx. kg Table 10: for 659 1) inipleat filter panel with flat section seal / minipleat filter panel with fluid seal 2) Related to minipleat filter panel 781 in the specified filter size 12 HPA terminal filter units - eaflet 6/1/2/N

13 eiling diffuser eiling diffuser Type 660 X etail drawing 19: 660 with top circular entry spigot etail drawing 20: etail X imensions of 660 and filter element size A 1 A Unit size N P Q ilter element size B H T 1) / / Nominal volume flow rate 2) l/s m³/h imensions in Weight Spigot code number Approx. (last digit kg of 1 ) 17 1, 3,, , 3,, , 8, , 8, , 8, , 8, , 8, , 8, , 8, , 8, 9 Table 11: for 660 1) inipleat filter panel with flat section seal / minipleat filter panel with fluid seal 2) Related to minipleat filter panel 781 in the specified filter size Spigot dimensions Ø Spigot code number (last digit of 1 ) Table 12: Spigot dimensions and code numbers HPA terminal filter units - eaflet 6/1/2/N 13

14 Wall grille 670 etail onstruction Three different installation depths, with sealing integrity test facility and measuring point for monitoring of the differential operating pressure. rille face plate made of sheet steel with powder coating (RA 9010) Type S-A or made of anodised aluminium profiles Type AS-A. aintenance rille face plate with concealed fixing to facilitate its removal for filter change and decontamination. Wall grille Type 670 etail drawing with code letters rille face plate Type ode letter 2 AS-A S-A A S Table 13: rille face plate for wall application N etail drawing 21: 670 imensions of 670 and filter element size Type AS-A AS-A AS-A S-A S-A S-A Unit size ilter size in B H T Nominal volume flow rate 1) l/s m³/h Wall grille imensions in N Weight Approx. kg ode letter 2 A A A S S S 1 Table 1: for 670 1) Related to minipleat filter panel 781 in the specified filter size 1 HPA terminal filter units - eaflet 6/1/2/N

15 Specification text Specification text HPA terminal filter units: HPA terminal filter unit for ceiling and wall installation as final filter (last filter stage) and for air distribution. itting of filter elements for separation of suspended particles. asing made of sheet steel with powder coating (RA 9010). asing with clamping mechanism (two-point or four-point fixing) for the HPA filter. Sealing integrity test facility, at the top of the unit, pressure measuring points to monitor differential operating pressure. iffuser face plate made of sheet steel with powder coating (RA9010) or anodised aluminium profiles. eiling diffuser Type 60: With side entry circular spigot eiling diffuser Type 650: With side entry rectangular spigot eiling diffuser Type 65: With manually adjustable shut-off damper and side entry circular spigot eiling diffuser Type 655: With automatic adjustable shut-off damper (pneumatic actuator) and side entry circular spigot eiling diffuser Type 656: With automatic adjustable shut-off damper (electric actuator) and side entry circular spigot eiling diffuser Type 659: With volume flow limiter and side entry circular spigot eiling diffuser Type 660: With top entry circular spigot Wall grille Type 670: Three different installation depths, with sealing integrity test facility and pressure measuring point : Nominal volume flow rate l/s (m³/h) imensions of casing imensions of diffuser/grille face plate Net weight kg Order number Type of diffuser/grille face plate ake: TROX ist of abbreviations A = Overall width of rectangular inlet spigot flange 650 = iameter of entry spigot = Overall dimension of case including entry spigot 650 = ace flange width = imensions from face flange to centerline of spigot 1 = asing height = Overall dimensions of flange = Overall dimensions of diffuser face plate N = Overall length of grille face plate (Type 670) = Top suspension distance between holes = Overall dimensions of casing S = istance from casing flange to damper operator cover U = asing extension HPA terminal filter units - eaflet 6/1/2/N 15

16 TROX mbh Siemensstraße och, ermany Phone +9 (0) 28 23/ ax +9 (0) 28 23/ mail troxfilter@trox.de ilters Subject to change / All rights reserved / TROX mbh (1/2010)

Ducted HEPA filter units for highly sensitive areas

Ducted HEPA filter units for highly sensitive areas Ducted HEPA filter units for highly sensitive areas Without prefilter casing: Type F60 With prefilter casing: Type F70 Duct casing for installation into ductwork, with or without prefilter Double-groove

More information

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems Filter

More information

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION Pharmaceutical clean room terminal filters as final filter stage with Mini Pleat filter panels

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

Particle Filter Box FKU

Particle Filter Box FKU Particle Filter Box FKU Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP Type TFP FOR CRITICAL AIR CLEANLINESS

More information

Slot diffusers for ceiling installation

Slot diffusers for ceiling installation X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger

More information

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems Filter

More information

Duct filter units. Duct HEPA filter units AKF

Duct filter units. Duct HEPA filter units AKF Duct HEPA filter units AKF Application Duct HEPA filter unit AKF is being used in the network of inlet and outlet ducts used to supply or extract air from the rooms with highest demands regarding air cleanness.

More information

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

Particle Filter Box Model FKF

Particle Filter Box Model FKF Particle Filter Box Model FKF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Rectangular multileaf

More information

Type VSD35. Nominal length up to 1500 mm: one spigot

Type VSD35. Nominal length up to 1500 mm: one spigot Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements

More information

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Type AK FOR LOW-LEAKAGE SHUT-OFF Circular shut-off dampers for shutting off volume flows in ventilation ducts

More information

VARYCONTROL VAV Dual Duct Terminal Boxes

VARYCONTROL VAV Dual Duct Terminal Boxes 5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk

More information

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Shut-off dampers. Type AKK. For contaminated air PD AKK 1 X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

For installation into ductwork

For installation into ductwork X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum

More information

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face 2/1/EN/3 Slot Diffuser Type VSD15 with 15 mm wide diffuser face Contents Air Diffuser Discharge Characteristics (horizontal) 2 Description 3 Air Diffuser Discharge Characteristics (alternating) 3 Construction

More information

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Homepage > Products > Air Diffusers > Industrial diffusers > Diffusers for high momentum > Type ISH Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Impulse diffusers with horizontal air discharge

More information

DRUM SLOT DIFFUSER TYPE: RT350

DRUM SLOT DIFFUSER TYPE: RT350 TYPE: RT3 RT1 + RP301 98 RT2 + RP302 37 123 13.5 75.5 214 Application The RT3 drum slot diffuser is suitable for the supply and exhaust of cooled and warmed air in offices, shops, meeting rooms, etc. The

More information

Fan - Powered Terminal Unit Series Flow

Fan - Powered Terminal Unit Series Flow 5/22/M/1 Fan - Powered Terminal Unit Series Flow Type TFP Trox (Malaysia) Sdn Bhd 20 Persiaran Bunga Tanjung 1 Senawang Land Industrial Park 70400 Seremban Negeri Sembilan Darul Khusus Malaysia Telephone

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL. Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL Type KUL FOR INSTALLATION INTO DUCTWORK Non-return dampers prevent unwanted airflows

More information

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m 2/18/EN/2 Air Handling Lights Type LR Recommended for use in rooms with ceiling heights of approx. 2.60... 4.00 m Contents Description Description... 2 Supply Air Construction LR-Z... 3 Extract Air Construction

More information

CONSTANTFLOW Volume Flow Controllers

CONSTANTFLOW Volume Flow Controllers 5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions

More information

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES Homepage > Products > External Louvres & Dampers > External weather louvres > External weather louvres > Type WG Type WG External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS,

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CD SERIES CD SERIES LINEAR SLOT DIFFUSERS QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman Moducel

More information

Lindab air filtration. Technical Catalogue

Lindab air filtration. Technical Catalogue Lindab air filtration Technical Catalogue ir filtration Overview Duct-filter units Duct pre-filter units KPF are designed to clean the air in air-conditioning and ventilating systems. Built-in filters

More information

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

ADJUSTABLE SLOT DIFFUSER TYPE: SE800 TYPE: SE800 Installation dimensions Construction with hanger brackets Construction without hanger brackets D C Application 7 E A 0 7 E A 0 The slot diffuser, type SE800 is used for the supply of cooled

More information

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1 X X testregistrierung Disc valves Type For supply air Circular disc valves with manually adjustable annular gap Nominal sizes 100, 125, 160, 200 mm Volume flow rate range 10 90 l/s or 36 324 m³/h Diffuser

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

LINEAR SLOT DIFFUSERS

LINEAR SLOT DIFFUSERS LINEAR SLOT DIFFUSERS MODEL CD Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk - www.jprservices.co.uk

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com PRODUCT BROCHURE Rectangular Displacement Diffuser RDW-FD smartemp.com DESCRIPTION The SMARTEMP Rectangular Displacement Diffuser, type RDW-FD (figure 1), produces a low velocity horizontal airflow pattern

More information

Ceiling Slot Diffuser Model DSX

Ceiling Slot Diffuser Model DSX Ceiling Slot Diffuser Model DSX Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R 1/3/EN/4 Ventilation Grilles Types TRS-K TRS-R TRSE-R Contents Description Description 2 Constructions Dimensions TRS-K 3 Constructions Dimensions TRS-R 4 Constructions Dimensions TRSE-R 5 Installation

More information

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

Splash-proof Terminal HEPA Filter

Splash-proof Terminal HEPA Filter Splash-proof Terminal HEPA Filter Type GTS Overview The Splash-proofed Terminal HEPA Filter GTS is designed and tested to extract a Minipleat -Media Pack, available in different heights, with a new application

More information

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment Maximum Protection in Filter Systems CGF/CGG GEA Ceiling Air Outlets Data & Facts GEA Heat Exchangers / GEA Air Treatment Table of Contents Technical Description... 3 Application and Components... 3 Components...

More information

Volume Flow Limiters Type VFL

Volume Flow Limiters Type VFL X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered

More information

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25 Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard applications regarding the supply air or extract air control in variable air

More information

Parts and characteristics

Parts and characteristics Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN MT Silent Series MIX LOW IN-LIN UT N Mixed low In-Line uct an MT Silent Series MT Silent 100/2~200/2 MT Silent 250~315 Low profile Mixed-flow fans with sound- absorbent insulation. xtreme ly quiet. General

More information

CAV controllers Type RN

CAV controllers Type RN 2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant

More information

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES T SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES

More information

ceiling swirl diffuser DQJ

ceiling swirl diffuser DQJ ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...

More information

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element Cleanroom systems Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. with pull-down outlet element DS 4178 E 01.201 Preliminary remarks Materials and designs As a rule, turbulent mixing ventilation is used

More information

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1 X X testregistrierung VAV terminal units Type Easy controller Compact controller Rectangular connection on the room end Circular connection on the fan end For supply air systems with demanding acoustic

More information

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser 1/1.5/B/1 Plaster In Grilles AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Telephone +44 (0) 1842

More information

ACCESSORIES FOR DUCT FANS

ACCESSORIES FOR DUCT FANS FOR DUCT FANS Duct fan Clamp Filter box Silencer Electric heater Duct fans are mostly used in low-to medium-pressure ducted systems with additional components such as heaters, filter boxes, dampers, etc.

More information

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type NAK. Gas-tight shut-off damper with pneumatic actuator Homepage > Products > Control units > Shut-Off dampers > Type NAK Type NAK FOR THE GAS-TIGHT SHUT-OFF OF DUCTS Gas-tight shut-off damper with pneumatic actuator Gas-tight shut-off dampers are designed

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single

More information

Mobile recleanable HEPA filter units for a flow of m 3 / h

Mobile recleanable HEPA filter units for a flow of m 3 / h Mobile recleanable HEPA filter units for a flow of 3.000 m 3 / h Page 1/11 consisting of Mobile online recleanable HEPA filter block, Type M-RHF hightec 1 x 2 and Mobile air conveyor block, Page 2/11 RHF

More information

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CE SERIES CE SERIES LINEAR SLOT DIFFUSERS CE SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman

More information

Gastight Rectangular Shut-Off Damper, Type GD-R

Gastight Rectangular Shut-Off Damper, Type GD-R Page 1/7 Page 2/7 Gastight Shut-Off System Gastight Rectangular Shut-Off Damper, Components such as damper systems used in ventilation systems for sensitive areas, like the chemical, the pharmaceutical

More information

MVF S.r.l. Via San Giovanni Bosco, Alessandria Tel Fax Web:

MVF S.r.l. Via San Giovanni Bosco, Alessandria Tel Fax Web: MV S.r.l. Via San Giovanni osco, 12-15121 Alessandria Tel. +39 131 68.73 - ax +39 131 56.334 Web: www.mvf.it -mail: info@mvf.it IN-LIN MIXD LOW DUT ANS ultra-quiet TD-SILNT Series TD-SILNT - MOD 16 TO

More information

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Type AKK FOR CONTAMINATED AIR Plastic circular shut-off dampers for shutting off aggressive

More information

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Regulation and shut-off damper SPB and SPC

Regulation and shut-off damper SPB and SPC SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are

More information

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS Home > PRODOTTI > Unità di regolazione > VARYCONTROL > Unità terminali VAV > Serie TVA Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control

More information

HIGH CAPACITY LINEAR SLOT DUFFUSERS

HIGH CAPACITY LINEAR SLOT DUFFUSERS HIGH CAPACITY LINEAR SLOT DUFFUSERS CB SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871

More information

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S PERFORATED FACE DIFFUSERS P SERIES P SERIES PERFORATED FACE DIFFUSERS P SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application:

More information

Grilles Linear Grilles

Grilles Linear Grilles T 1.1/1/EN/2 Grilles Linear Grilles for Walls, Floors, Doors, Rectangular and Circular Ducts TROX GmbH Telephone +9/28 /2 02-0 Telefax +9/28 /202-2 Heinrich-Trox-Platz e-mail trox@trox.de D-0 Neukirchen-Vluyn

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades

More information

Active Chilled Beams

Active Chilled Beams T 2.4/2/EN/1 Active Chilled Beams Type DID300B TROX GmbH Telephone +49/2 45/2 02-0 Telefax +49/2 45/202-25 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn www.troxtechnik.com Contents

More information

Extract-air grille with ATK plenum box

Extract-air grille with ATK plenum box GB0416 09.17 UPK LØV-R Extract-air grille with ATK plenum box Bespoke dimensions, BxH variants Available with and without plenum box Grille with mounting frame Removable damper for easy cleaning ATK box

More information

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille Halton WDD/WSD Universal Grille Horizontal air supply, suitable also for exhaust Adjustable vertical front vanes, adjustable horizontal rear vanes: WDD, adjustable horizontal vanes: WSD Aluminium construction

More information

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

LINEAR SLOT DUFFUSERS

LINEAR SLOT DUFFUSERS LINEAR SLOT DUFFUSERS CE SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL 2AA Tel: 010 12 - Fax: 010 1 2 - email sales@jprservices.co.uk

More information

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS Airodyne multi leaf volume control tampers have been specifically designed for use in air conditioning and ventilation system for volume,

More information

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser Halton DFB Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation flush to the ceiling, light-weight aluminium design Circular duct connection with rubber gasket All sizes

More information

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise Halton AWE/AWU Universal Grille Horizontal air supply, suitable also for exhaust Fixed front vanes, stable throw pattern with vertical 15 deflection: AWE, no deflection: AWU Adjustable rear vanes for horizontal

More information

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise LINEAR BAR GRILLES T SERIES Quality and e!ciency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk

More information

NV series. Induction VAV air volume control terminals

NV series. Induction VAV air volume control terminals NV series Induction VAV Description Table of contents Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model overview / dimensions 4-5 Sound data NVOAOOB...

More information

Compact Grille Model KG

Compact Grille Model KG Compact grille KG Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...3

More information

Pressure relief dampers

Pressure relief dampers X X testregistrierung Pressure relief dampers Type Closed blade For the prevention of excess pressure in rooms Pressure relief dampers for gas fire extinguishing systems and transformer substations Air

More information

FIXED BLADE LOUVRE FACED CEILING DIFFUSER

FIXED BLADE LOUVRE FACED CEILING DIFFUSER IFFUSERSFixed lade Louvre Faced FIXE LE LOUVRE FCE CEILING IFFUSER range of fixed blade ceiling diffusers with a 2 position, removable core for use in heating / cooling applications where the mounting

More information

CG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms

CG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms CG INLET CEILING Inlet ceiling with the laminar discharge flow for operating rooms Pleasant climate controllable as required Economical operation due to the point protection principle Extremely low number

More information

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers Incorporating V2.0 Product spec >>> > Series DJ - Drum jet diffusers Diffusers Drum jets (Premium) Recommended for: Wall, ceiling & duct Supply Overview Exceptional throw Throw completely adjustable Drum

More information

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

More information

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles Incorporating V2.0 Product spec >>> > Series DD - Double deflection grilles Grilles Double deflection Recommended for: Wall, ceiling & duct Supply & extract Overview Enhanced functionality As per the name,

More information

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise EYELASH DIFFUSERS E SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 71526 - Fax: 01707 71 527 - email sales@jprservices.co.uk

More information

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles Incorporating V2.1 Product spec >>> > Series ECG - Egg crate grilles Grilles Egg crate Recommended for: Wall, ceiling & duct Extract Overview Industry standard extract grille Plastic egg crate core optional

More information