IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO62727W/V2

Size: px
Start display at page:

Download "IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO62727W/V2"

Transcription

1 IES LM MEASUREMENT AND TEST REPORT For MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO62727W/V2 Report Type: Test Engineer: Electrical and Photometric tests including: Luminous Flux, Power Factor, Chromaticity, Luminous Intensity Distribution Carl Du Report Number: RSZ Test Date: to Report Date: Reviewed By: Prepared By: Accreditation: Blake Zhang / EE Engineer Bay Area Compliance Laboratories Corp. (Dongguan). No.69,Pulongcun,Puxinhu Industrial Area, Tangxia, Tel: Fax: Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

2 1. Product Description Bay Area Compliance Laboratories Corp. (Dongguan) General Information: 3 samples were received on and used for testing. Model Tested: Brand Name: Product Designation: Burning Time Before Test: RRECO62727W/V2 Maxlite LED Recessed Downlight 0hour(For New Products) Rated Values: Rated Voltage/Frequency: Rated Power: Nominal CCT: V AC 50/60Hz 27 W 2700K Family Declaration MaxLite Inc declares that there are some differences between multiple models and tested model. Details as below: Model Number CCT Test Item RRECO62727W/V2 2700K ALL RRECO62730W/V2 RRECO62740W/V2 3000K 4000K Initial Photometric and Electrical Measurements Note: 1. The applicant MaxLite Inc declares that their product with model RRECO62727W/V2, RRECO62730W/V2, RRECO62740W/V2 are the same to the product in report# RSZ A1, RSZ A2 and RSZ A3and is authorized by original applicant to use their test data. 2. All the data in previous report (RSZ A1, RSZ A2 and RSZ A3) is shared in report. 2. Standards Used IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C : Harmonic Emission Limits Related Power Quality Requirements for Lighting IES TM-30-15: IES Method for Evaluating Light Source Color Rendition (This method is not in IAS accreditation scope) 3. Description of Test Equipment Device Manufacture Model No Serial No Test Range 2.0m integrating sphere Calibration date Calibration due date EVERFINE R R spectroradiometer EVERFINE HAAS nm Digital Power Meter EVERFINE PF2010A V/20A Digital CC&CV EVERFINE WY305-V V/5A Report No. RSZ Page 2 of 32

3 Device Manufacture Model No Serial No Test Range DC Power Supply Rapid Recording Photometer Standard Light Source Special zerovoltage synchronous switching AC 1.5m temperature integrating sphere High-precision rapid spectral analysis system Digital power meter Programmable Precision DC Power Supply Bay Area Compliance Laboratories Corp. (Dongguan) Calibration date Calibration due date EVERFINE PHOTO-2000F lm 200klm SENSING N/A LSD N/A EVERFINE DPS1010-YF T 0-150V, 0-300V SENSING SPR-600 S ~50 C EVERFINE HAAS-2000 M112048CA nm YOKOGAWA WT N/A ITECH IT ~32V thermometer SENSING NA NA C Standard Light Source Precision frequency power supply SENSING NA LSD N/A ALL Power APW-105N AC Power Supply EVERFINE VPS1030 PWM V±10% 50Hz 0-150V, 0-300V DC Power Supply EVERFINE WY V/5A Power Meter YOKOGAWA WT KB35700 Goniophotometer EVERFINE GO-R5000 YG108492N /30/60/150/30 0/600 V 1600mm,3000 W/10A 0 C~50 C;- 20 C~60 C Wireless Remote Sensor N/A 433MHz N/A Standard Light Source EVERFINE D N/A Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI). 4. Test Method Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25 C±1 C during measurement. And relative humidity is less than 65%. Integrating Sphere System The system includes AC power source, digital power meter, DC power supply, Spectroradiometer, and integrating sphere. The integrating sphere system is calibrated by standard spectrum light source before measurement. 4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the light output (luminous flux) measurements is U=1.8% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=20K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.8(K=2), at the 95% confidence level. Report No. RSZ Page 3 of 32

4 Bay Area Compliance Laboratories Corp. (Dongguan) The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=25K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1(K=2), at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Goniophotometer System The goniophotometer system is calibrated by standard light source before measurement. Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The vertical angle (γ) test intervals were set no more than 1 degree while data for 5 degree intervals is reported. The horizontal angle (C plane) test intervals were set no more than 22.5 degree. The uncertainty of the luminous intensity is U=1.6% (K=2), at the 95% confidence level. Fidelity Index and Gamut Index Calculation The R f, R g was calculated according to IES TM by using calculation tools. The calculation was based on the measured SPD from 380nm to 780nm with 1nm intervals. All the colors in this report is for reference only. Report No. RSZ Page 4 of 32

5 Bay Area Compliance Laboratories Corp. (Dongguan) 5. Test Result [Integrating Sphere System] The test data for RRECO62727W/V2 Total operating time for integrating sphere test: 1.0 hour Test orientation: Downward Photometric and Electrical Measurement Result Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor Luminous Flux(lm) Efficacy (lm/w) Radiant Flux (W) CCT (K) Duv x y u' v' Color Rendering Index Ra 83.3 R1 R2 R3 R R5 R6 R7 R R9 R10 R11 R R13 R14 R Report No. RSZ Page 5 of 32

6 SPD (normalized to Y=100) Bay Area Compliance Laboratories Corp. (Dongguan) Fidelity Index and Gamut Index Fidelity Index R f 85 Gamut Index R g 93 3 Spectral Power Distribution Comparison Test source Reference source l (nm) 140 Plot of R g versus R f R g R f Report No. RSZ Page 6 of 32

7 Bay Area Compliance Laboratories Corp. (Dongguan) Chroma Shift by Hue R f by Hue 20% % 10% % 80 0% -5% % 60-15% -20% Hue Bin Hue Bin Color Vector Graphic Refenerce Illuminat Test Source Report No. RSZ Page 7 of 32

8 Color Evaluation Sample Bay Area Compliance Laboratories Corp. (Dongguan) Color Fidelity by CES Sample CES01 CES03 CES05 CES07 CES09 CES11 CES13 CES15 CES17 CES19 CES21 CES23 CES25 CES27 CES29 CES31 CES33 CES35 CES37 CES39 CES41 CES43 CES45 CES47 CES49 CES51 CES53 CES55 CES57 CES59 CES61 CES63 CES65 CES67 CES69 CES71 CES73 CES75 CES77 CES79 CES81 CES83 CES85 CES87 CES89 CES91 CES93 CES95 CES97 CES Fidelity Index, R f Report No. RSZ Page 8 of 32

9 1.0 Bay Area Compliance Laboratories Corp. (Dongguan) Relative Spectral Power Distribution nm mw nm mw nm mw nm mw nm mw E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E+01 Report No. RSZ Page 9 of 32

10 Bay Area Compliance Laboratories Corp. (Dongguan) nm mw nm mw nm mw nm mw nm mw E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E+00 Report No. RSZ Page 10 of 32

11 Bay Area Compliance Laboratories Corp. (Dongguan) CIE 1931 x y Chromaticity Diagram Step Chromaticity Quadrangles sample 7-STEP 2200K 7-STEP 2500K 7-STEP 2700K 7-STEP 3000K 7-STEP 3500K 7-STEP 4000K 7-STEP 4500K 7-STEP 5000K 7-STEP 5700K 7-STEP 6500K Report No. RSZ Page 11 of 32

12 The test data for RRECO62730W/V2 Total operating time for integrating sphere test: 1.0 hour Test orientation: Downward Bay Area Compliance Laboratories Corp. (Dongguan) Photometric and Electrical Measurement Result Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor Luminous Flux(lm) Efficacy (lm/w) Radiant Flux (W) CCT (K) Duv x y u' v' Color Rendering Index Ra 82.3 R1 R2 R3 R R5 R6 R7 R R9 R10 R11 R R13 R14 R Report No. RSZ Page 12 of 32

13 SPD (normalized to Y=100) Bay Area Compliance Laboratories Corp. (Dongguan) Fidelity Index and Gamut Index Fidelity Index R f 83 Gamut Index R g Spectral Power Distribution Comparison Test source Reference source l (nm) 140 Plot of R g versus R f R g R f Report No. RSZ Page 13 of 32

14 Bay Area Compliance Laboratories Corp. (Dongguan) Chroma Shift by Hue R f by Hue 20% % 10% % 80 0% -5% % 60-15% -20% Hue Bin Hue Bin Color Vector Graphic Refenerce Illuminat Test Source Report No. RSZ Page 14 of 32

15 Color Evaluation Sample Bay Area Compliance Laboratories Corp. (Dongguan) Color Fidelity by CES Sample CES01 CES03 CES05 CES07 CES09 CES11 CES13 CES15 CES17 CES19 CES21 CES23 CES25 CES27 CES29 CES31 CES33 CES35 CES37 CES39 CES41 CES43 CES45 CES47 CES49 CES51 CES53 CES55 CES57 CES59 CES61 CES63 CES65 CES67 CES69 CES71 CES73 CES75 CES77 CES79 CES81 CES83 CES85 CES87 CES89 CES91 CES93 CES95 CES97 CES Fidelity 40 Index, R f Report No. RSZ Page 15 of 32

16 1.0 Bay Area Compliance Laboratories Corp. (Dongguan) Relative Spectral Power Distribution nm mw nm mw nm mw nm mw nm mw E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E+01 Report No. RSZ Page 16 of 32

17 Bay Area Compliance Laboratories Corp. (Dongguan) nm mw nm mw nm mw nm mw nm mw E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E+00 Report No. RSZ Page 17 of 32

18 Bay Area Compliance Laboratories Corp. (Dongguan) CIE 1931 x y Chromaticity Diagram Step Chromaticity Quadrangles sample 7-STEP 2200K 7-STEP 2500K 7-STEP 2700K 7-STEP 3000K 7-STEP 3500K 7-STEP 4000K 7-STEP 4500K 7-STEP 5000K 7-STEP 5700K 7-STEP 6500K Report No. RSZ Page 18 of 32

19 The test data for RRECO62740W/V2 Total operating time for integrating sphere test: 1.0 hour Test orientation: Downward Bay Area Compliance Laboratories Corp. (Dongguan) Photometric and Electrical Measurement Result Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor Luminous Flux(lm) Efficacy (lm/w) Radiant Flux (W) CCT (K) Duv x y u' v' Color Rendering Index Ra 84.9 R1 R2 R3 R R5 R6 R7 R R9 R10 R11 R R13 R14 R Report No. RSZ Page 19 of 32

20 SPD (normalized to Y=100) Bay Area Compliance Laboratories Corp. (Dongguan) Fidelity Index and Gamut Index Fidelity Index R f 83 Gamut Index R g Spectral Power Distribution Comparison Test source Reference source l (nm) 140 Plot of R g versus R f R g R f Report No. RSZ Page 20 of 32

21 Bay Area Compliance Laboratories Corp. (Dongguan) Chroma Shift by Hue R f by Hue 20% % 10% % 80 0% -5% % 60-15% -20% Hue Bin Hue Bin Color Vector Graphic Refenerce Illuminat Test Source Report No. RSZ Page 21 of 32

22 Color Evaluation Sample Bay Area Compliance Laboratories Corp. (Dongguan) Color Fidelity by CES Sample CES01 CES03 CES05 CES07 CES09 CES11 CES13 CES15 CES17 CES19 CES21 CES23 CES25 CES27 CES29 CES31 CES33 CES35 CES37 CES39 CES41 CES43 CES45 CES47 CES49 CES51 CES53 CES55 CES57 CES59 CES61 CES63 CES65 CES67 CES69 CES71 CES73 CES75 CES77 CES79 CES81 CES83 CES85 CES87 CES89 CES91 CES93 CES95 CES97 CES Fidelity 40 Index, R f Report No. RSZ Page 22 of 32

23 1.0 Bay Area Compliance Laboratories Corp. (Dongguan) Relative Spectral Power Distribution nm mw nm mw nm mw nm mw nm mw E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E+01 Report No. RSZ Page 23 of 32

24 Bay Area Compliance Laboratories Corp. (Dongguan) nm mw nm mw nm mw nm mw nm mw E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E+00 Report No. RSZ Page 24 of 32

25 Bay Area Compliance Laboratories Corp. (Dongguan) CIE 1931 x y Chromaticity Diagram Step Chromaticity Quadrangles sample 7-STEP 2200K 7-STEP 2500K 7-STEP 2700K 7-STEP 3000K 7-STEP 3500K 7-STEP 4000K 7-STEP 4500K 7-STEP 5000K 7-STEP 5700K 7-STEP 6500K Report No. RSZ Page 25 of 32

26 [Goniophotometer System] Bay Area Compliance Laboratories Corp. (Dongguan) The test data for RRECO62727W/V2 Total operating time for luminous intensity distribution: 1.5 hours Test orientation: Downward Electrical Measurement Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor Photometric Measurement Luminous Flux (lm) Efficacy (lm/w) I max (cd) S/MH (C0/180) S/MH (C90/270) Luminous Intensity Distribution C0/180 C45/225 C90/270 C135/315 AVG. Beam Angle (50% I max): Field Angle (10% I max): Report No. RSZ Page 26 of 32

27 Bay Area Compliance Laboratories Corp. (Dongguan) Luminous Intensity (cd) Distribution Data γ C Report No. RSZ Page 27 of 32

28 Bay Area Compliance Laboratories Corp. (Dongguan) Luminous Intensity (cd) Distribution Data (cont.) γ C Report No. RSZ Page 28 of 32

29 Zonal Lumen Density Measurement Bay Area Compliance Laboratories Corp. (Dongguan) Deg Flux (lm) % Deg Flux (lm) % Report No. RSZ Page 29 of 32

30 6. Product Photo Bay Area Compliance Laboratories Corp. (Dongguan) The Produce Photo for Model RRECO62727W/V2 Report No. RSZ Page 30 of 32

31 Bay Area Compliance Laboratories Corp. (Dongguan) The Produce Photo for Model RRECO62730W/V2 Report No. RSZ Page 31 of 32

32 Bay Area Compliance Laboratories Corp. (Dongguan) The Produce Photo for Model RRECO62740W/V2 ***********END OF REPORT*********** Report No. RSZ Page 32 of 32

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO81227W/V2

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO81227W/V2 IES LM-79-08 MEASUREMENT AND TEST REPORT For MaxLite Inc 12 York Ave West Caldwell, NJ. 07006 Test Model: RRECO81227W/V2 Report Type: Electrical and Photometric tests including: Luminous Flux, Chromaticity,

More information

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India IES LM-79-08 MEASUREMENT AND TEST REPORT For Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida 201305 UP India Test Model: L20H80/50K Report Type: Electrical and Photometric tests

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED11WA19/300/827K-GU24-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED15WA21/300/830K-GU24-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED11WA19/300/840K-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India IES LM-79-08 MEASUREMENT AND TEST REPORT For Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida 201305 UP India Test Model: L14EH80-W/HB/50K Report Type: Electrical and Photometric

More information

TEST REPORT For Company:

TEST REPORT For Company: TEST REPORT For Company: EiKO Global, LLC 23220 W. 84th Street, Shawnee, KS 66227 Model: LED6WG25/830K-DIM-G4 Report Type: Testing and Report According to ENERGY STAR Program Requirements for Lamps V1.0

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP35AUT550BPCMA Test & Report By: Sean Zhuo Engineer:

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006 LM-79-08 Test Report For MAXLITE INC (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): PTD100UT341SMxxx Representative (Tested)

More information

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA LM-79-08 Test Report For MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA OUTDOOR FULL-CUTOFF WALL-MOUNTED AREA LUMINAIRES Model name(s): BP45AUT5XXBPM0 BP45AUT5XXWPM0 Remark: The

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou,

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8030M57-A Representative (Tested) Model: LED-8030M57-A Model Different

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8036M40-A Representative (Tested) Model: LED-8036M40-A Model Different

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8050M50-HV Representative (Tested) Model: LED-8050M50-HV Model Different

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8029E40-A LED-8029M40-A Remark : The suffix of the model name E stand

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8029E57-A LED-8029M57-A Remark : The suffix of the model name E stand

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8024M40-A LED-8024-CW-E40-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8033E40-A LED-8033-CW-E27-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8033E57-A LED-8033-DL-E27-A Remark: The two models are the same

More information

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146,

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146, Photometric Test Report Relevant Standards IES LM-79-2008 Prepared For MaxLite Inc 0 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x46, rraghavan@maxlite.com Catalog Number BLHE-223DU50-[blank,

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8046M40-A LED-8046-CW-E40-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-2000LM-3000K Representative (Tested) Model: RPT-LEDBIAX-2000LM-3000K

More information

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT LM-79-08 Test Report For Model Different: All construction and rating are the same, except CCT Test & Report By: Review By: Sean Zhuo Engineer: Sean Zhuo Date: Apr.24,2015 Manager: Tommy Liang Note: This

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Fujian Lightning Optoelectronic Co., Ltd.Shenzhen Branch 5F, Building B, second phase of Chuangjian Industrial

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E57-A LED-8038-DL-E27-A Remark: The two models are the same

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8046M57-A LED-8046-DL-E40-A Remark: The two models are the same

More information

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Luminaire Model name(s): LED-8050M50 Representative (Tested) Model: LED-8050M50 Model Different

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Room 316, Building 2, No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Model:100B10C10(Ra2)

More information

LIGHT EFFICIENT DESIGN

LIGHT EFFICIENT DESIGN LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E40-A LED-8038-CW-E27-A Remark: The two models are the same

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E30-A LED-8038-NW-E27-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) SANHUI INDUSTRY ZONE CUNWEI VILLAGE HENGLI TOWN DONGGUAN GUANGDONG 523000 CN Outdoor Wall-Mounted Area

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. LED LAMP Model name(s): TLFLF220XYYZZ Remark:The letter

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. LED LAMP Model name(s): TLFLF80XYYZZ Remark:The letter

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

LIGHT EFFICIENT DESIGN, LLC

LIGHT EFFICIENT DESIGN, LLC LM-79-08 Test Report For LIGHT EFFICIENT DESIGN, LLC (Brand Name: N/A) 188 S.Northwest Highway, Cary, IL60013, USA LED Luminaires Model name(s): LED-7320-40K-G2 Representative (Tested) Model: LED-7320-40K-G2

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Model:40B18C12(Ra2) Report Type: 10000

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For HOCAN GROUP CO.,LTD (Brand Name: SEPICN LED LIGHTING) Rm.1902, Easey Comm. Bldg., 253-261 Hennessy Road,Wanchai, Hong Kong Direct Linear Ambient Luminaires Low-bay Luminaires for

More information

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED) LM-79-08 Test Report For SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Block 6,Zhengdaan Industry Park,No.172,Xiangshan Road,Luotian Village, SongGang Town,Baoan District,Shenzhen Replacement Lamps

More information

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For HOCAN GROUP CO.,LTD (Brand Name: SEPICN LED LIGHTING) Rm.1902, Easey Comm. Bldg., 253-261 Hennessy Road,Wanchai, Hong Kong Direct Linear Ambient Luminaires Low-bay Luminaires for

More information

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA LM-79-08 Test Report For MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA Four-Foot Linear Replacement Lamps Model name(s): MT8Z04 Representative (Tested) Model:

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503 LM-79-08 Test Report For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): IGTWP-0301550 (5000K) Model Difference:

More information

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED) LM-79-08 Test Report For SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Block 6,Zhengdaan Industry Park,No.172,Xiangshan Road,Luotian Village, SongGang Town,Baoan District,Shenzhen Replacement Lamps

More information

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA LM-79-08 Test Report For Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 1130SG-35T Remark:

More information

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W Customer Company & Address: MaxLite ADD: 12 York Ave, West Caldwell, NJ 07006 Contact Person: Francisco Garza Telephone: 973-244-7300x142 Telephone: fgarza@maxlite.com Manufacturer: Country of Origin:

More information

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0. LED Wall-PACK/Flood Light DataSheet Cat# 71391 Wet Locations Use RoHS QPL ID # PSQKCNWM Model: 71391 Input Voltage 100-277VAC Input Current 0.5A @100V / 0.2A @277V Input Power 28 W OVERALL LAMP PARAMETERS

More information

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS LED Wall-PACK/FloodLight DataSheet Cat# 71393 Model: RoHS Wet Locations Use 71393 Input Voltage 100-277VAC Input Current 0.69A @120V / 0.31A @277V Input Power 79 W Power Factor PF 0.95 OVERALL LAMP PARAMETERS

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For SHENZHEN MTC LIGHTING CO., LTD. NO.65,Chuangyi Road,Dalang Street,Baoan District,Shenzhen,GuangDong Province,CHINA

More information

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71376 UPC Number 601986713764 Description LED Bullet Flood Light 30 W 2300 Lumens Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71372 UPC Number 601986713726 Description LED Bullet Flood Light 1 LED 800 Lumen Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, , Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, +91

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Revolution Lighting Technologies, Inc 2280 Ward Ave. Simi Valley, CA. 93065 Roman Sukharev, (877)

More information

MEASUREMENT AND TEST REPORT

MEASUREMENT AND TEST REPORT IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux Report of Test LLIA000965 006 Integrating Sphere Report Performance Summary Voltage Current Power Frequency Power Factor Current THD Total Luminous Flux Efficacy Chromaticity (x,y) (u',v') Duv CCT CRI

More information

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux Report of Test LLIA000901 008B Integrating Sphere Report Performance Summary Voltage Current Power Frequency Power Factor Current THD Total Luminous Flux Efficacy Chromaticity (x,y) (u',v') Duv CCT CRI

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL13048-001A CR4T-790L-27K-12-E26GU24 Date: 08/22/18 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy Lehrmann

More information

Soraa Internal Report: IES LM79 08

Soraa Internal Report: IES LM79 08 PRELIMINARY Soraa Internal Report: IES LM79 08 Test results reported for: Part Number: SM16-09-36D-930-03 Soraa MR16, GU5.3/12V, 3000K, 95CRI, 9W, 36degree Relevant Standards IES LM-79 ANSI C78.377 IES

More information

Soraa Internal Report: IES LM79-08

Soraa Internal Report: IES LM79-08 PRELIMINARY Soraa Internal Report: IES LM79-08 Test results reported for: Customer Reference P/N: SR111-18-08D-830-03 Manufacturing P/N: SR111-18-08D-830-03 Soraa AR111, G53/12V, 3000K, 80CRI, 18.5W, 8degree

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08239-001A LN4-34L-40K-xxx Date: 05/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09173-004B IG-NM-5S-A-30K-UL-WH xxx Date: 09/21/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Zongjie

More information

IESNA LM79: 2008 Photometric Test Report

IESNA LM79: 2008 Photometric Test Report IESNA LM79: 28 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-28 Report Prepared For David Delgado Manger Applications and Certification MaxLite Description of Sample:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06624-001A VG-A-xx-5W-A-57K-UL w/ VG-PSSV Date: 08/20/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy

More information

T8 4ft 5000K EazyLux EZ8450D7R07

T8 4ft 5000K EazyLux EZ8450D7R07 PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08 Sample Tested T8 4ft 5000K EazyLux EZ8450D7R07 Prepared for: James Pan, Ph.D. Luxul Technology, Inc. 2905 Stender Way, Suite 22 Santa Clara, CA 95054 Phone:

More information

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG Customer Company & Address: GREEN CREATIVE ADD: Room 1206-7 New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Contact Person: Guillaume Vidal Telephone: +86 21-62320308 Email address: guillaume@gc-lighting.com

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ. Test #: L11125507 Date: 12/5/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L11125507 MLVT22D4535 Report Prepared For: MaxLite

More information

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

INDEPENDENT TEST LABORATORY REPORT No A

INDEPENDENT TEST LABORATORY REPORT No A Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

Lighting Sciences

Lighting Sciences Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY OUTPUT LUMENS ANGLE

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 77- Report Number: Model: PL-1 BXSPCxx2LGE3K-xxxxxx w/xa-sp1bls or XSPCxx2LGE3 Date: 8/8/21 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ, 07006

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ, 07006 Test #: L07120201 Date: 7/11/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L07120201 MLSWP30LED50 Report Prepared For: MAXLITE

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000901-044A One ERP ESP050W-1200-42 LED driver 120.0Vac, 60.00Hz, 0.3999A, 47.20W, 0.984PF, 11.8%THD(i) Total Light Output Luminaire Power Luminous Efficacy Performance Summary 3548

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Address...: Maxlite Inc. 12 York Ave,West Caldwell,NJ,USA Brand Name...: Maxlite Report No... : BTR66.181.16.38.3 Product Name...: Downlight Recessed Model

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB02540 PAGE: 1 OF 7 CATALOG NUMBER: VAN1LED12NW (SURFACE MOUNT - DROP LENS) LUMINAIRE: WHITE ALUMINUM SHEET METAL HOUSING, ONE WHITE CIRCUIT BOARD WITH 48 LEDS, FROSTED POLYCARBONATE DROP

More information

Report of Test LLIA A-R02*

Report of Test LLIA A-R02* Report of Test LLIA000762-006A-R02* *This test report supersedes test report LLIA000762-006A-R01 each. Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous

More information

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 LM 79 08 Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 Model(s) This test report presents the results of measurements performed on the product Spectrum Lighting SX1605RDLED18W35KE1/SM/OP

More information

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260 PHOTOMETRIC TESTING & EVALUATION Sample Tested Man-D-Tec UNILED-12-4K Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260 Phone: 480-998-0325 Technical Report Number 70150753 August 8, 2017

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Address...: Maxlite Inc. 12 York Ave,West Caldwell,NJ,USA Brand Name...: Maxlite Report No... : BTR66.181.16.38.27 Product Name...: Downlight Solid State Retrofit

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Address...: Maxlite Inc. 12 York Ave,West Caldwell,NJ,USA Brand Name...: Maxlite Report No... : BTR66.181.16.38.29 Product Name...: Downlight Recessed Model

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L121500401 Date: 12/8/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500401 Report Prepared For: Bartco Lighting 5761 Research

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07003-001A RUL-HT-5ME-C-40K-12-UF-N-ES-K2 Date: 12/16/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Michael Hash

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000930-001A Catalog Number: AR300-D-MO-K40-80--4-XX-LOH-XXXX-120 One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver 120.0Vac, 60.00Hz, 0.1556A, 18.56W, 0.994PF, 5.2%THD(i) Total

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000930-002A Catalog Number: AR300-D-HO-K40-80--4-XX-LOH-XXXX-120 One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver 120.0Vac, 60.00Hz, 0.2331A, 27.89W, 0.997PF, 5.9%THD(i) Total

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Address...: Maxlite Inc. 12 York Ave,West Caldwell,NJ,USA Brand Name...: Maxlite Report No... : BTR66.181.16.38.28 Product Name...: Downlight Recessed Model

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name... : Blackjack lighting Address... : 1553 Barclay Blvd. Buffalo Grove, IL 689 Brand Name...: Blackjack lighting Report No.... : BTR66.181.15.4.53 Product Name...:

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name... : Blackjack lighting Address... : 1553 Barclay Blvd. Buffalo Grove, IL 689 Brand Name...: Blackjack lighting Report No.... : BTR66.181.15.35.1 Product Name...:

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Blackjack lighting Address...: 1553 Barclay Blvd. Buffalo Grove, IL 689 Brand Name...: Blackjack lighting Report No... : BTR66.181.16.5.31 Product Name...:

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000762-003A Catalog Number: MLS3-I/D-HO/HO-K40-4-X-WSOP/LOH-X-XXX each. Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous Efficacy

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730 Test #: L04144501 Date: 4/15/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L04144501 MLFP22EP3641 Report Prepared For: Maxlite

More information

Calibration Due Date Chroma Programmable AC Source 61604

Calibration Due Date Chroma Programmable AC Source 61604 Test #: L12132802 Date: 12/18/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L12132802 LW52-BRZ-110-00 Report Prepared For:

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB02175 PAGE: 1 OF 7 CATALOG NUMBER: SK16XL20RYY LUMINAIRE: STAMPED STEEL CEILING PAN WITH WHITE FINISH, 10 LED BOARDS EACH WITH 8 LEDS, ACRYLIC DROP LENS WITH SMOOTH FINISH. LAMPS: EIGHTY

More information

Photometric Indoor Test Report

Photometric Indoor Test Report Photometric Indoor Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 Prepared For Elemental LED Inc, DBA Diode LED Wes Buck Suite 211,1195 Park Ave. Emeryville, CA 94608 United States Catalog

More information

Report of Test LLIA A-R01*

Report of Test LLIA A-R01* Report of Test LLIA000849-002A-R01* *This test report supersedes test report LLIA000849-002A One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver. Total Light Output Luminaire Power Luminous Efficacy

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L08133001 Date: 8/22/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L08133001 LUX-LED-360-4R-UNV-U Report Prepared

More information

Integrating Sphere Test Report

Integrating Sphere Test Report Integrating Sphere Test Report Relevant Standards IES LM-79-2008 ANSI C78.377-2011, ANSI C82.77-2002 CIE 13.3-1995, CIE 15-2004 Prepared For Elemental LED Inc, DBA Diode LED Wes Buck Suite 211,1195 Park

More information

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Osram Sylvania 200 Ballardvale Street Wilmington, Mass Report No: L071407402 Date: 7/30/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071407402 Report Prepared For: Osram Sylvania 200 Ballardvale

More information