1 Micro Motion ELITE Coriolis Flow and Density Meters Product Data Sheet PS-00374, Rev AE July 2017 Ultimate real world performance Unchallengeable ELITE performance on liquid mass flow, volume flow, and density measurements Best-in-class gas mass flow measurement Reliable two-phase flow measurement for the most challenging applications Designed to minimize process, mounting, and environmental effects Best fit-for-application Scalable platform for the widest range of line size and application coverage including hygienic, cryogenic, high pressure, and high temperature Available with the broadest range of I/O offerings highlighted by expansive digital protocol support Superior measurement confidence Smart Meter Verification delivers complete, online verification of device health and performance, continuously or on-demand at the press of a button Globally leading ISO/IEC calibration facilities offers best in class uncertainty of ±0.014% Intelligent sensor design mitigates the need for zero calibration in the field

2 ELITE Series Coriolis Flow and Density Meters July 2017 Micro Motion ELITE Coriolis flow and density meters Micro Motion ELITE meters provide unmatched flow and density measurement performance to deliver the ultimate control and confidence in your most complex and challenging liquid, gas, and slurry applications. Tip If you need help determining which Micro Motion products are right for your application, check out the Micro Motion Technical Overview and Specification Summary and other resources available at Achieving the ultimate flow fit for your application Able to achieve the best fit for your flow measurement with a wide range of tube designs and flow rate coverage to best serve your application Peak performance in a drainable design with a variety of industry approvals for use in strictly governed sanitary applications Scalable platform for a broad array of application coverage including hygienic, cryogenic, and high pressure Smart Meter Verification: advanced diagnostics for your entire system A comprehensive test that can be run locally or from the control room to provide confidence in your meter functionality and performance Verifies that your meter performs as well as the day it was installed, giving you assurance in less than 90 seconds Save significant expenditure by reducing labor and outsourced calibration service costs while eliminating process interruption Industry-leading capabilities that unleash your process potential Available with the most extensive offering of transmitter and mounting options for maximum compatibility with your system State of the art, ISO-IEC compliant calibration stands achieving ±0.014% uncertainty drive best in class measurement accuracy The most robust communication protocol offering in the industry including Smart Wireless True multi-variable technology measures necessary flow and density process variables simultaneously Widest selection of safety, country, and custody transfer approvals Unparalleled performance in two-phase flow conditions Featuring the lowest frequency Coriolis sensors that ensure the two-phase mixture vibrates with the tube to drastically reduce entrained gas uncertainty contributions Unmatched MVD transmitter technology with digital signal processing (DSP) delivers the fastest response and refresh rates enabling accurate batch and other two-phase flow measurement Measure fluids with any Gas Void Fraction (GVF). The relationship to mass flow accuracy varies with application 2

3 July 2017 ELITE Series Coriolis Flow and Density Meters Measurement principles As a practical application of the Coriolis effect, the Coriolis mass flow meter operating principle involves inducing a vibration of the flow tube through which the fluid passes. The vibration, though it is not completely circular, provides the rotating reference frame which gives rise to the Coriolis effect. While specific methods vary according to the design of the flow meter, sensors monitor and analyze changes in frequency, phase shift, and amplitude of the vibrating flow tubes. The changes observed represent the mass flow rate and density of the fluid. Mass flow measurement The measuring tubes are forced to oscillate producing a sine wave. At zero flow, the two tubes vibrate in phase with each other. When flow is introduced, the Coriolis forces cause the tubes to twist resulting in a phase shift. The time difference between the waves is measured and is directly proportional to the mass flow rate. A. Inlet pickoff displacement B. No flow C. Outlet pickoff displacement D. Time E. Inlet pickoff displacement F. With flow G. Outlet pickoff displacement H. Time difference I. Time Density measurement The measuring tubes are vibrated at their natural frequency. A change in the mass of the fluid contained inside the tubes causes a corresponding change to the tube natural frequency. The frequency change of the tube is used to calculate density. Temperature measurement Temperature is a measured variable that is available as an output. The temperature is also used internal to the sensor to compensate for temperature influences on Young s Modulus of Elasticity. 3

4 ELITE Series Coriolis Flow and Density Meters July 2017 Meter characteristics Measurement accuracy is a function of fluid mass flow rate independent of operating temperature, pressure, or composition. However, pressure drop through the sensor is dependent upon operating temperature, pressure, and fluid composition. Specifications and capabilities vary by model and certain models may have fewer available options. Please refer to the Online Store Sizing and Selection Tool at the Emerson web site ( for detailed information regarding performance and capabilities. All meters with the CMF designation (CMF, CMFHC, CMFS) are members of the ELITE meter family and should be considered to possess the same qualities and specifications as other ELITE family meters unless specifically noted. The letter at the end of the base model code (for example, CMF100M) represents wetted part material and/or application designation: M = 316L stainless steel, L = 304L stainless steel, H = nickel alloy C22, P = high pressure, A = high temperature 316L stainless steel, B = high temperature nickel alloy C22, Y = Super Duplex (UNS S32750). Detailed information about the complete product model codes are described later in this document. Performance specifications Reference operating conditions For determining the performance capabilities of our meters, the following conditions were observed/utilized: Water at 68 to 77 F and 14.5 to 29 psig (20 to 25 C and 1 to 2 barg) Accuracy based on industry leading accredited calibration stands according to ISO 17025/IEC All models have a density range up to 5 g/cm 3 (5000 kg/m 3 ) Accuracy and repeatability Accuracy and repeatability on liquids and slurries Performance Specification Standard Optional (1) Mass/volume flow accuracy (2)(3) ±0.10% of rate ±0.05% of rate Mass/volume flow repeatability ±0.05% of rate ±0.025% of rate Density accuracy (3) (4)(5) ± g/cm 3 (±0.5 kg/m 3 ) ± g/cm 3 (±0.2 kg/m 3 ) Density repeatability ± g/cm 3 (±0.2 kg/m 3 ) ± g/cm 3 (±0.1 kg/m 3 ) Temperature accuracy ±1 C ±0.5% of reading Temperature repeatability ±0.2 C Integral temp sensor, BS1904 Class, DIN43760 Class A (± x Temp C) Case temperature sensors (6) BS1904 Class, DIN Class B (± x Temp C) - Qty 3 (1) Optional accuracy is not available for high temperature models (base model code A/B) or high capacity models (CMFHC2/3/4) (2) Stated flow accuracy includes the combined effects of repeatability, linearity, hysteresis, orientation and other non-linearities. (3) For cryogenic applications with process temperatures below -100 C, the liquid mass flow accuracy is ±0.35% of rate and density accuracy specification does not apply. (4) The standard density accuracy option for the sensor models CMFS010, CMFS015 is ±0.002 g/cm 3 (±2 kg/m 3 ), optional accuracy is ± g/cm 3 (±0.5 kg/m 3 ). (5) The standard density accuracy option for the sensor model CMFS007 is ±0.002 g/cm 3 (±2 kg/m 3 ). (6) Case temperature sensors are used for Environmental Temperature Compensation of Density measurement. Only applicable to CMFS025- CMFS150 models. 4

5 July 2017 ELITE Series Coriolis Flow and Density Meters Accuracy and repeatability on gases Performance specification CMF models CMFS models Mass flow accuracy (1) ±0.35% of rate ±0.25% of rate Mass flow repeatability ±0.20% of rate Temperature accuracy ±1 C ±0.5% of reading Integral temp sensor, BS1904 Class, DIN43760 Class A (± x Temp C) Temperature repeatability ±0.2 C (1) Stated flow accuracy includes the combined effects of repeatability, linearity, hysteresis, orientation and other non-linearities. Liquid flow rates Nominal flow rate Micro Motion has adopted the term nominal flow rate, which is the flow rate at which water at reference conditions causes approximately 14.5 psig (1 barg) of pressure drop across the meter. Mass flow rates for stainless steel models: 304L (L), 316L (M/A), and Super Duplex (Y) Nominal line size Nominal flow rate Maximum flow rate Style inch mm lb/min kg/h lb/min kg/h CMFS007M 1/12 DN CMFS010M 1/10 DN CMFS015M 1/6 DN CMFS025M 1/4 DN CMFS040M 3/8 DN , ,640 CMFS050M 1/2 DN , ,820 CMFS075M 3/4 DN , ,500 CMFS100M 1" DN , ,900 CMFS150M 1-1/2 DN ,000 1,980 54,000 CMF010M/L 1/10 DN CMF025M/L 1/4 DN , ,180 CMF050M/L 1/2 DN , ,800 CMF100M/L 1" DN , ,200 CMF200M/L/ A CMF300M/L/ A 2" DN50 1,760 47,900 3,190 87,100 3" DN80 5, ,000 9, ,000 CMF350M/A 4 DN100 10, ,000 15, ,000 CMF400M/A 6" DN150 15, ,000 20, ,000 CMFHC2M/Y 8" DN200 27, ,000 54,000 1,470,000 CMFHC3M/Y 10" DN250 49,000 1,340,000 94,000 2,550,

6 ELITE Series Coriolis Flow and Density Meters July 2017 Nominal line size Nominal flow rate Maximum flow rate Style inch mm lb/min kg/h lb/min kg/h CMFHC4M 12" DN300 75,000 2,040, ,000 3,266,000 Mass flow rates for nickel alloy C22 (H/B) and high pressure (P) models Nominal line size Nominal flow rate Maximum flow rate Style inch mm lb/min kg/h lb/min kg/h CMFS010H/P 1/10 DN CMFS015H/P 1/6 DN CMFS025H/P 1/4 DN ,770 CMFS050H/P 1/2 DN , ,130 CMFS100H/P 1" DN , ,500 CMFS150H/P 1-1/2 DN ,500 1,800 49,100 CMF010H/P 1/10 DN CMF025H 1/4 DN6 48 1, ,180 CMF050H 1/2 DN , ,800 CMF100H 1" DN , ,200 CMF200H/B 2" DN50 1,760 47,900 3,190 87,100 CMF300H/B 3" DN75 5, ,000 9, ,000 CMF350P 4 DN100 10, ,000 15, ,000 CMF400H/B/P 6" DN150 15, ,000 20, ,000 Volume flow rates for stainless steel models: 304L (L), 316L (M/A), and Super Duplex (Y) Style Nominal flow rate Maximum flow rate gal/min barrels/h l/h gal/min barrels/h l/h CMFS007M CMFS010M CMFS015M CMFS025M , ,100 CMFS040M , ,640 CMFS050M , ,820 CMFS075M , ,500 CMFS100M , ,900 CMFS150M , ,000 CMF010M/L CMF025M/L , ,180 CMF050M/L , ,800 CMF100M/L , ,

7 July 2017 ELITE Series Coriolis Flow and Density Meters Style CMF200M/L/ A CMF300M/L/ A Nominal flow rate Maximum flow rate gal/min barrels/h l/h gal/min barrels/h l/h , , , ,000 1,200 1, ,000 CMF350M/A 1,283 1, ,000 1,800 2, ,000 CMF400M/A 1,820 2, ,000 2,400 3, ,000 CMFHC2M/Y 3,350 4, ,000 6,440 9,200 1,470,000 CMFHC3M/Y 5,880 8,400 1,340,000 11,270 16,100 2,550,000 CMFHC4 8,990 12,800 2,040,000 14,350 20,500 3,266,000 Volume flow rates for nickel alloy C22 (H/B) and high pressure (P) models Style Nominal flow rate Maximum flow rate gal/min barrels/h l/h gal/min barrels/h l/h CMFS010H/P CMFS015H/P CMFS025H/P ,770 CMFS050H/P , ,130 CMFS100H/P , ,500 CMFS150H/P , ,100 CMF010H/P CMF025H , ,180 CMF050H , ,800 CMF100H , ,200 CMF200H/B , ,100 CMF300H/B 700 1, ,000 1,200 1, ,000 CMF350P 1,283 1, ,000 1,800 2, ,000 CMF400H/B/P 1,820 2, ,000 2,400 3, ,

8 ELITE Series Coriolis Flow and Density Meters July 2017 Gas flow rates When selecting sensors for gas applications, pressure drop through the sensor is dependent upon operating temperature, pressure, and fluid composition. Therefore, when selecting a sensor for any particular gas application, it is highly recommended that each sensor be sized using the Online Store Sizing and Selection Tool at the Emerson web site ( The table below indicates mass flow rates that produce approximately 25 psig (1.7 barg) pressure drop on natural gas with molecular weight of 17 at 60 F (16 C) and 500 psig (34 barg). Gas flow rates for all models Mass Volume lb/min kg/h SCFM Nm 3 /h CMFS007M CMFS010M CMFS010H/P CMFS015M CMFS015H/P CMFS025M CMFS025H/P CMFS040M CMFS050M ,000 CMFS050H/P CMFS075M 54 1,400 1,200 2,000 CMFS100M 100 2,900 2,400 4,100 CMFS100H/P 98 2,600 2,200 3,700 CMFS150M 220 6,100 5,000 8,500 CMFS150H/P 200 5,600 4,600 7,800 CMF010M/H/L CMF010P CMF025M/L/H CMF050M/L/H ,100 CMF100M/L/H 130 3,600 3,000 5,100 CMF200M/L/H/A/B ,000 9,000 15,000 CMF300M/L/H/A/B 1,300 36,000 30,000 51,000 CMF350M/A/P 2,300 62,000 51,000 88,000 CMF400M/H/A/B/P 3,300 92,000 76, ,000 CMFHC2M/A/Y 5, , , ,000 CMFHC3M/A/Y 8, , , ,000 CMFHC4M 14, , , ,

9 July 2017 ELITE Series Coriolis Flow and Density Meters Note Standard (SCFM) reference conditions for natural gas with molecular weight of 17 are 14.7 psia (1 bara) and 60 F (15 C). Zero stability Zero stability is used when the flow rate approaches the low end of the flow range where the meter accuracy begins to deviate from the stated accuracy rating, as depicted in the turndown section below. When operating at flow rates where meter accuracy begins to deviate from the stated accuracy rating, accuracy is governed by the formula: accuracy = (zero stability/flow rate) x 100%. Repeatability is similarly affected by low flow conditions. Turndown capabilities The graph and table below represent an example of the measurement characteristics under various flow conditions. At flow rates requiring large turndowns (greater than 20:1), the zero stability values may begin to govern capability dependent upon flow conditions and meter in use :1 A :1 2:1 A. Accuracy, % B. Flow rate, % of nominal B Sample of accuracy and pressure drop across flow rate Turndown from nominal flow rate 60:1 20:1 10:1 2:1 1:1 Accuracy ±% Pressure drop psig (barg) (0.0006) 0.06 (0.004) 0.22 (0.015) 4.11 (0.28) 14.5 (1.0) Zero stability for stainless steel models: 304L (L), 316L (M/A), and Super Duplex (Y) Zero stability lb/min kg/h CMFS007M CMFS010M CMFS015M CMFS025M CMFS040M CMFS050M CMFS075M CMFS100M

10 ELITE Series Coriolis Flow and Density Meters July 2017 Zero stability lb/min kg/h CMFS150M CMF010M/L CMF025M/L CMF050M/L CMF100M/L CMF200M/L/A CMF300M/L/A CMF350M CMF350A CMF400M/A CMFHC2M/Y/A CMFHC3M/Y/A CMFHC4M Zero stability values for nickel alloy C22 models (H/B) Zero stability lb/min kg/h CMFS010H CMFS015H CMFS025H CMFS050H CMFS100H CMFS150H CMF010H CMF025H CMF050H CMF100H CMF200H/B CMF300H/B CMF400H/B Zero stability values for high pressure (P) models Zero stability lb/min kg/h CMFS010P CMFS015P CMFS025P

11 July 2017 ELITE Series Coriolis Flow and Density Meters Zero stability lb/min kg/h CMFS050P CMFS100P CMFS150P CMF010P CMF350P CMF400P Process pressure ratings Sensor maximum working pressure reflects the highest possible pressure rating for a given sensor. Process connection type and environmental and process fluid temperatures may reduce the maximum rating. Refer to the Technical Data Sheet for common sensor and fitting combinations. All sensors comply with ASME B31.3 process piping code and Council Directive 97/23/EC of 29 May 1997 on pressure equipment. Some sensor models also comply with the ASME B31.1 power piping design code as indicated with a pressure rating in the table. Sensors with JIS process connections do not comply with ASME B31.1 power piping code. Sensor maximum working pressure for stainless steel models: 304L (L) and 316L (M/A) CMFS007M, CMFS010M, CMFS015M CMFS025M, CMFS040M, CMFS050M, CMFS075M, CMFS100M, CMFS150M ASME B31.3 compliance ASME B31.1 compliance psig barg psig barg 1, n/a n/a 1, , CMF010M/L 1, , CMF025M/L, CMF050M/L 1, , CMF100M/L 1, , CMF200M/L/A 1, , CMF300M/L/A 1, , CMF350M/A 1, , CMF400M/A 1, , CMFHC2M/A 1, CMFHC3M/A 1, CMFHC4M 1, n/a n/a 11

12 ELITE Series Coriolis Flow and Density Meters July 2017 Sensor maximum working pressure for nickel alloy C22 models (H/B) ASME B31.3 compliance ASME B31.1 compliance psig barg psig barg CMFS010H, CMFS015H 6, n/a n/a CMFS025H, CMFS050H 3, , CMFS100H, CMFS150H 3, n/a n/a CMF010H 3, n/a n/a CMF025H 2, n/a n/a CMF050H 2, n/a n/a CMF100H 2, n/a n/a CMF200H/B 2, n/a n/a CMF300H/B 2, n/a n/a CMF400H/B 2, n/a n/a Sensor maximum working pressure for high pressure models (P) ASME B31.3 compliance ASME B31.1 compliance psig barg psig barg CMFS010P, CMFS015P 6, n/a n/a CMFS025P, CMFS050P 3, , CMFS100P, CMFS150P 3, n/a n/a CMF010P 6, n/a n/a CMF350P 2, n/a n/a CMF400P 2, n/a n/a Sensor maximum working pressure for Super Duplex models (Y) ASME B31.3 compliance ASME B31.1 compliance psig barg psig barg CMFHC2Y, CMFHC3Y 2, n/a n/a Case pressure Case pressure for CMF models Case maximum pressure (1) NAMUR NE132 Typical burst pressure (2) psig barg psig barg psig barg CMF , , CMF , , CMF , , CMF , ,

13 July 2017 ELITE Series Coriolis Flow and Density Meters Case maximum pressure (1) NAMUR NE132 Typical burst pressure (2) psig barg psig barg psig barg CMF , , CMF , , CMF , , CMF , , CMFHC2 n/a n/a , CMFHC3 n/a n/a , CMFHC4 n/a n/a (1) Derived from B31.3 international standards. (2) Values do not apply for high-temperature models (base model codes A or B). Case pressure for CMFS models Case maximum pressure (1) NAMUR NE132 Typical burst pressure psig barg psig barg psig barg CMFS007 1, , , CMFS010 1, , , CMFS015 1, , , CMFS , , CMFS , , CMFS , , CMFS , , CMFS , , CMFS , , (1) Case maximum pressure is determined by applying a safety factor of 4 to typical burst pressure. Operating conditions: Environmental Vibration limits Meets IEC , endurance sweep, 5 to 2000 Hz, 50 sweep cycles at 1.0 g. 13

14 ELITE Series Coriolis Flow and Density Meters July 2017 Temperature limits Sensors can be used in the process and ambient temperature ranges shown in the temperature limit graphs. For the purposes of selecting electronics options, temperature limit graphs should be used only as a general guide. If your process conditions are close to the gray area, consult with your Micro Motion representative. Note In all cases, the electronics cannot be operated where the ambient temperature is below 40 F ( 40 C) or above +140 F (+60 C). If a sensor is to be used where the ambient temperature is outside of the range permissible for the electronics, the electronics must be remotely located where the ambient temperature is within the permissible range, as indicated by the shaded areas of the temperature limit graphs. Temperature limits may be further restricted by hazardous area approvals. Refer to the hazardous area approvals documentation shipped with the sensor or available at The extended-mount electronics option allows the sensor case to be insulated without covering the transmitter, core processor, or junction box, but does not affect temperature ratings. When insulating the sensor case at elevated process temperatures (above 140 F), please ensure electronics are not enclosed in insulation as this may lead to electronics failure. For the CMFS007 sensor, the difference between the process fluid temperature and the average temperature of the case must be less than 210 F (99 C) Ambient and process temperature limits for ELITE CMFS007, CMFS025 CMFS150 meters 140 (60) 140 (60) B 113 (45) Tamb A 40 ( 40) 148 ( 100) B T amb = Ambient temperature F ( C) T proc = Process temperature F ( C) A = All available electronic options B= Remote mount electronics only 58 ( 50) 400 (204) Tproc 14

15 July 2017 ELITE Series Coriolis Flow and Density Meters Ambient and process temperature limits for ELITE CMF***M/L/H/P (excludes special order cryogenic modifications) and CMFS meters Tamb 140 (60) A 140 (60) B 113 (45) 40 ( 40) B 148 ( 100) 400 ( 240) Tproc 400 (204) T amb = Ambient temperature F ( C) T proc = Process temperature F ( C) A = All available electronic options B= Remote mount electronics only Ambient and process temperature limits for special order cryogenic ELITE meters Tamb 140 (60) 40 ( 40) A B 148 ( 100) 400 ( 240) Tproc 176 (80) T amb = Ambient temperature F ( C) T proc = Process temperature F ( C) A = All available electronic options B= Remote mount electronics only Ambient and process temperature limits for high temperature ELITE meters 140 (60) Tamb A 40 ( 40) 148 ( 100) 58 ( 50) B Tproc 662 (350) T amb = Ambient temperature F ( C) T proc = Process temperature F ( C) A = All available electronic options B= Remote mount electronics only 15

16 ELITE Series Coriolis Flow and Density Meters July 2017 Ambient and process temperature limits for Super Duplex ELITE meters 140 (60) 140 (60) B 113 (45) Tamb A 40 ( 40) B 148 ( 100) 40 ( 40) Tproc 400 (204) T amb = Ambient temperature F ( C) T proc = Process temperature F ( C) A = All available electronic options B= Remote mount electronics only Note For Super Duplex models operating above 177 C, please consult the factory before purchase. Operating conditions: Process Process temperature effect For mass flow measurement, process temperature effect is defined as the change in sensor flow accuracy due to process temperature change away from the calibration temperature. Temperature effect can be corrected by zeroing at the process conditions. For density measurement, process temperature effect is defined as the change in sensor density accuracy due to process temperature change away from the calibration density. See installation manual for proper setup and configuration. Process temperature effect for all models % of maximum flow rate per C Density accuracy per C g/cm 3 kg/m 3 CMFS007, CMFS010, CMFS015 CMFS025, CMFS040, CMFS050, CMFS075, CMFS100, CMFS150 ± ± ±0.015 ± ± ±0.015 CMF010 ± ± ±0.015 CMF025, CMF050, CMF100 ± ± ±0.015 CMF200, CMF300 ± ± ±0.015 CMF350, CMF400 ± ± ±0.015 CMFHC2 ± ± ±

17 July 2017 ELITE Series Coriolis Flow and Density Meters % of maximum flow rate per C Density accuracy per C g/cm 3 kg/m 3 CMFHC3 ± ± ±0.015 CMFHC4 ± ± ±0.015 Process pressure effect Process pressure effect is defined as the change in sensor mass flow and density accuracy due to process pressure change away from the calibration pressure. This effect can be corrected by dynamic pressure input or a fixed meter factor. Please refer to the calibration sheet for the specific meter pressure compensation coefficient. If no pressure compensation coefficient is provided, use the typical values listed in the table below. See installation manual for proper setup and configuration. Process pressure effect for CMFS models CMFS007, CMFS010, CMFS015 Mass Flow (% of rate) Density per psi per bar g/cm 3 per psi kg/m 3 per bar none none none none CMFS025 none none CMFS CMFS050 M CMFS050 H/P none none CMFS CMFS100 M CMFS100 H/P CMFS150M CMFS150H/P Process pressure effect for CMF and CMFHC models Liquid flow (% of rate) Gas flow (% of rate) Density per psi per bar per psi per bar g/cm 3 per psi kg/m 3 per bar CMF010 none none none none none none CMF025 none none none none CMF050 none none none none CMF CMF200 M/A/L CMF200 H/B CMF300 M/A/L CMF300 H/B CMF CMF400 M/A CMF400 H/B/P

18 ELITE Series Coriolis Flow and Density Meters July 2017 Liquid flow (% of rate) Gas flow (% of rate) Density per psi per bar per psi per bar g/cm 3 per psi kg/m 3 per bar CMFHC CMFHC CMFHC Pressure relief ELITE sensors are available with a rupture disk installed on the case. Rupture disks are meant to vent process fluid from the sensor case in the unlikely event of a flow tube breach. Some users connect a pipeline to the rupture disk to help contain escaping process fluid. For more information about rupture disks, contact Micro Motion Customer Service. If the sensor has a rupture disk, it should remain installed at all times as it would otherwise be necessary to re-purge the case. If the rupture disk is activated by a tube breach, the seal in the rupture disk will be broken, and the Coriolis meter should be removed from service. The rupture disk is located as follows on the meter, and the warning sticker shown is placed next to it. The sensor must be oriented so that personnel and equipment will not be exposed to any discharge along the pressure relief path. CAUTION! Stay clear of the rupture disk pressure relief area. High-pressure fluid escaping from the sensor can cause severe injury or death. 18

19 July 2017 ELITE Series Coriolis Flow and Density Meters Hazardous area classifications Approvals and certifications Type Approval or certification (typical) CSA and CSA C-US (CMFS sensors) Ambient temperature: 40 to +140 F ( 40 to +60 C) Class I, Div. 1, Groups A, B, C, and D. Class I, Div. 2, Groups A, B, C, and D. Class II, Div.1, Groups E, F, and G. CSA and CSA C-US (CMF sensors) Ambient temperature: 40 to +140 F ( 40 to +60 C) Class I, Div. 1, Groups C and D. ATEX Class I, Div. 2, Groups A, B, C, and D. Class II, Div.1, Groups E, F, and G. II 2G Ex ib IIB/IIC T1 T4/T5/T6 Gb IECEx NEPSI Ex ib IIB/IIC T1 T4/T5/T6 Gb Ex na IIC T1-T4/T5 Gc Ex ib IIB/IIC T1 T6 Gb Ex ibd 21 T450 C-T85 C Ex na IIC T1 T6 Gc II 2D Ex ib IIIC T(1) C Db IP66 II 3G Ex na IIC T1 T4/T5 Gc II 3D Ex tc IIIC T(1) C Dc IP66 Ingress Protection Rating EMC effects DIP A22 T(1) T1-T6 IP 66/67 for sensors and transmitters Complies with EMC directive 2004/108/EC per EN Industrial Complies with NAMUR NE-21 ( ) Marine approval classifications For models CMF200M, CMF300M, CMF350M, CMF400M, CMFHC2M, CMFHC3M, CMFHC4M. Marine approval Lloyd s Register ENV1, ENV2, ENV3, ENV5 Det Norske Veritas- Germanischer Lloyd Bureau Veritas American Bureau of Shipping Nippon Kaiji Kyokai Country United Kingdom Norway-Germany France USA Japan For models CMFS010H, CMFS015H, CMFS025H, CMFS050H, CMFS100H, CMFS150H. Marine approval Country Lloyd s Register ENV1, ENV2, ENV3, ENV5 United Kingdom Det Norske Veritas- Germanischer Lloyd Norway-Germany 19

20 ELITE Series Coriolis Flow and Density Meters July 2017 Industry standards Type Weights and Measures for custody transfer applications: Hygienic approvals (some models) Industry standards and commercial approvals Standard MID OIML R117/R137 National Type Evaluation Program (NTEP) Measurement Canada INMETRO Brazil ASME BPE EHEDG, 3A NAMUR: NE132 (burst pressure, sensor flange to flange length), NE131 Pressure Equipment Directive (PED) Canadian Registration Number (CRN) Dual Seal ASME B31.1 power piping code and ASME B31.3 process piping code SIL2 and SIL3 safety certifications All Super Duplex materials comply with NORSOK M-650 Note Approvals shown are for ELITE meters configured with a core processor for remote 4-wire connection to a Micro Motion transmitter. Meters with integral electronics may have more restrictive approvals. Refer to the Product Data Sheet for each transmitter for details. When a meter is ordered with hazardous area approvals, detailed information is shipped along with the product. More information about hazardous approvals, including detailed specifications and temperature graphs for all meter configurations is available on the ELITE Series product page at the Micro Motion web site ( Transmitter interface A Micro Motion flowmeter system is highly customizable to provide a configuration that is tailor-fit to specific applications. Robust transmitter offerings allow a multitude of mounting options: Compact mounting integral to the sensor Field mount variants for harsh conditions Compact control room DIN rail packages for optimal locating in a control cabinet Specific fit-for-purpose solutions for two-wire connectivity or filling and dosing machinery integration Micro Motion meters are available with an expansive selection of input and output connectivity options including the following: 4-20 ma HART WirelessHART EtherNet/IP FOUNDATION fieldbus PROFIBUS Modbus Other protocols may be available on request 20

21 July 2017 ELITE Series Coriolis Flow and Density Meters Physical specifications Materials of construction General corrosion guidelines do not account for cyclical stress, and therefore should not be relied upon when choosing a wetted material for your Micro Motion meter. Please refer to the Micro Motion Corrosion Guide for material compatibility information. Wetted part materials Stainless steel Sensor only weight Nickel alloy 316L 316L 32Ra 304L C22 Super Duplex lb kg CMFS CMFS CMFS CMFS CMFS CMFS CMFS CMFS CMFS CMF CMF CMF CMF CMF CMF CMF CMF CMFHC CMFHC CHFHC4 1, Note Weight specifications are based upon ASME B16.5 CL 150 flange and do not include electronics. Heat jackets and steam kits are also available. Table 1: Non-wetted part materials Component Enclosure rating 316L/CF-3M stainless steel Sensor housing Optional for CMFS models 300 series stainless steel Polyurethane-painted aluminum Core processor housing NEMA 4X (IP66/67) Junction box NEMA 4X (IP66) 21

22 ELITE Series Coriolis Flow and Density Meters July 2017 Table 1: Non-wetted part materials (continued) Component 1700/2700 transmitter housing 3700 transmitter housing 2400S transmitter housing 2200S transmitter housing FMT transmitter housing Enclosure rating 316L/CF-3M stainless steel 300 series stainless steel Polyurethane-painted aluminum NEMA 4X (IP66) NEMA 4X (IP66/67) NEMA 4X (IP66/67) NEMA 4X (IP66/67) NEMA 4X (IP66/67) Optional for 32 or 64 Ra Flanges Sensor type Stainless steel 316L & cryogenic Nickel alloy C22 Nickel alloy C22/316L stainless steel Hygienic Flange types ASME B16.5 weld neck flange (up to CL600) ASME B16.5 weld neck flange RTJ face (up to CL600) ASME B16.5 weld neck flange raised face (up to CL600) ASME B16.5 wafer style EN weld neck flange Type B1, B2, C, D, E, N (up to PN100) JIS B2220 weld neck raised face (up to 20K) VCO, VCR swagelok compatible fitting Hygienic tri-clamp compatible ASME B16.5 lap joint flange (up to CL900/1500) EN lap joint flange Type B, D (up to PN160) JIS B2220 lap joint flange (up to 20K) ASME B16.5 weld neck flange (up to CL2500) VCO swagelok compatible fitting EN weld neck flange Type B, D (up to PN250) Hygienic tri-clamp compatible Hygienic fittings (tri-clamp ASME BPE) Hygienic couplings (DIN A/2A/3A; DIN11851; ISO 2852/DIN 11850; ISO 2852/ISO 1127; SMS 1145) Note For flange compatibility, please refer to the Online Store Sizing and Selection Tool at the Emerson web site ( 22

23 July 2017 ELITE Series Coriolis Flow and Density Meters Dimensions These dimensional drawings are intended to provide a basic guideline for sizing and planning. They are representative of a 316 stainless steel model fitted with ASME B16.5 CL 150 flange, and 2400 or 5700 transmitter. Face-to-Face (Dim. A, below) dimensions for all ELITE meters with each available process connection can be found in the ELITE Technical Data Sheet. Complete and detailed dimensional drawings can be found through the product drawings link in our online store ( Note Accuracy: ±1/8 inch (±3 mm) Representative of a 316 stainless steel model fitted with ASME B16.5 CL 150 flange, and 2400 or 5700 transmitter Example dimensions for CMFS models Note For full dimensional details, refer to the ELITE Technical Data Sheet. Figure 1: CMFS 007, 010, and 015 models 5-1/4 (132) B C D A Figure 2: CMFS 025, 040, 050, 075, 100, and 150 models Note For full dimensional details, refer to the ELITE Technical Data Sheet. A 5-1/4 (132) B C D 23

24 ELITE Series Coriolis Flow and Density Meters July 2017 Dim. A ASME B16.5 CL150 Dim. B Dim. C Dim. D Inch mm Inch mm Inch mm Inch mm CMFS / / / /8 54 CMFS / / / /8 54 CMFS / / / /8 54 CMFS / / / /4 82 CMFS / / / /4 82 CMFS / / / /4 82 CMFS / / / CMFS / / / CMFS / / / Example dimensions for CMF010 through CMF100 models Note For full dimensional details, refer to the ELITE Technical Data Sheet. Figure 3: CMF010 model 7-7/8 (199) 7-1/8 (181) 7-13/16 (197) 9 (229) 1-3/4 (46) Figure 4: CMF025 through CMF100 models Note For full dimensional details, refer to the ELITE Technical Data Sheet. A C D E B Note Accuracy: ±1/8 inch (±3 mm) Representative of a 316 stainless steel model fitted with ASME B16.5 CL 150 flange, and 2400 transmitter 24

25 July 2017 ELITE Series Coriolis Flow and Density Meters Dim. A ASME B16.5 CL150 Dim. B Dim. C Dim. D Dim. E Inch mm Inch mm Inch mm Inch mm Inch mm CMF010???????6? 1-5/?8? CMF / / / /8 42 CMF / / / / CMF / / / /8 90 Example dimensions for CMF200 through CMFHC4 models Note For full dimensional details, refer to the ELITE Technical Data Sheet. Figure 5: CMF200 through CMFHC4 models A C D B E Note Accuracy: ±1/8 inch (±3 mm) Representative of a 316 stainless steel model fitted with ASME B16.5 CL 150 flange, and 2400 transmitter Dim. A ASME B16.5 CL150 Dim. B Dim. C Dim. D Dim. E Inch mm Inch mm Inch mm Inch mm Inch mm CMF / / / / /8 144 CMF / / / / /4 208 CMF / / / / /8 212 CMF / / / / /4 274 CMFHC2 42-3/ / / /4 324 CMFHC3 43-3/ / / CMFHC4 47-3/ / / /

26 ELITE Series Coriolis Flow and Density Meters July 2017 Ordering information code structure A complete sensor model code includes the ordering options. Example code CMFS Sensor series 025 Sensor size M Base model 313 Process connections N Case and hygienic options 0 Electronics interface A Conduit connections M Approvals E Languages Z Calibration Z Measurement application software Z Factory options Base model descriptions s M, L, H, Y, P, A, and B are model designations used to identify the type of meter. Material M 316L stainless steel L 304L stainless steel H Nickel alloy C22 Y Super Duplex (UNS S32750) P Nickel alloy C22/316L stainless steel A High temperature 316L stainless steel B High temperature nickel alloy C

27 July 2017 ELITE Series Coriolis Flow and Density Meters s available by model Available codes M L H Y P B A CMFS007 1/12 (DN1) M CMFS010 1/10 (DN2) M H P CMFS015 1/6 (DN3) M H P CMFS025 1/4 (DN6) M H P CMFS040 3/8 (DN10) M CMFS050 1/2 (DN15) M H P CMFS075 3/4 (DN20) M CMFS100 1 (DN25) M H P CMFS /2 (DN40) M H P CMF010 1/10 (DN2) M L H P CMF025 1/4 (DN6) M L H CMF050 1/2 (DN15) M L H CMF100 1 (DN25) M L H CMF200 2 (DN50) M L H B A CMF300 3 (DN80) M L H B A CMF350 4 (DN100) M P A CMF400 6 (DN150) M H P B A CMFHC2 8 (DN200) M Y A CMFHC3 10 (DN250) M Y A CMFHC4 12 (DN300) M Process connections CMFS010H and CMFS015H (nickel alloy C22) 323 #4 VCO N06022 Swagelok compatible fitting 1/4 N10276 NPT female adapter 334 #4 VCO N06022 Swagelok compatible fitting 520 1/2-inch CL150 ASME B16.5 F304/F304L Lap joint flange N06022 stub 521 1/2-inch CL300 ASME B16.5 F304/F304L Lap joint flange N06022 stub mm 10K JIS B 2220 F304/F304L Lap joint flange N06022 stub 523 DN15 PN40 DIN 2656 F304/F304L Lap joint flange Form C face, N06022 stub 524 DN15 PN40 EN F304/F304L Lap joint flange Type B1, N06022 stub 27

28 ELITE Series Coriolis Flow and Density Meters July 2017 CMFS007M, CMFS010M, and CMFS015M (316L stainless steel) 172 DN25 PN40 EN F316/F316L Weld neck flange Type B1 176 DN15 PN40 EN F316/F316L Weld neck flange Type B1 177 DN15 PN100 EN F316/F316L Weld neck flange Type B2 178 DN15 PN100 EN F316/F316L Weld neck flange Type D 183 DN25 PN40 EN F316/F316L Weld neck flange Type D mm 10K JIS B 2220 F316/F316L Weld neck flange Raised face mm 20K JIS B 2220 F316/F316L Weld neck flange Raised face 310 DN15 PN40 EN F316/F316L Weld neck flange Type D 313 1/2 CL150 ASME B16.5 F316/F316L Weld neck flange Raised face 314 1/2 CL300 ASME B16.5 F316/F316L Weld neck flange Raised face 315 1/2 CL600 ASME B16.5 F316/F316L Weld neck flange Raised face 319 #8 VCO 316/316L Swagelok compatible fitting 1/2 316 NPT female adapter 321 (1) 1/2 Tri-Clamp compatible 316L Hygienic fitting 323 #4 VCO 316/316L Swagelok compatible fitting 1/4 NPT female adapter 324 #4 VCO 316/316L Swagelok compatible fitting 1/4 tube compression fitting adapter 325 #4 VCO 316/316L Swagelok compatible fitting 6mm tube compression fitting adapter 334 #4 VCO 316/316L Swagelok compatible fitting 335 #8 VCO 316/316L Swagelok compatible fitting 344 (2)(3) 3/4 Tri-Clamp compatible 345 (2) (3) DN10 ISO 2852/ISO 1127 tube 346 (2) (3) DN15 ISO 2852/DIN tube 316L 316L 316L Hygienic fitting Hygienic fitting Hygienic fitting (1) Sensor is 3A authorized but not EHEDG certified when ordered with this fitting code. (2) Sensor is 3A authorized and EHEDG certified when ordered with this fitting code. Only available with case and hygienic code H or T. (3) Process connections 344, 345, 346 are not available for model CMFS007 sensors. CMFS010P and CMFS015P (nickel alloy C22/316L stainless steel) 150 1/2 CL900/1500 ASME B16.5 F316/F316L Weld neck flange Raised face 191 1/2 CL2500 ASME B16.5 F316/F316L Weld neck flange Raised face 319 #8 VCO 316/316L Swagelok compatible fitting 1/2 316 NPT female adapter 323 #4 VCO 316/316L Swagelok compatible fitting 1/4 NPT female adapter 28

29 July 2017 ELITE Series Coriolis Flow and Density Meters 324 #4 VCO 316/316L Swagelok compatible fitting 1/4 tube compression fitting adapter 325 #4 VCO 316/316L Swagelok compatible fitting 6 mm tube compression fitting adapter 334 #4 VCO 316/316L Swagelok compatible fitting 335 #8 VCO 316/316L Swagelok compatible fitting CMFS025H and CMFS050H (nickel alloy C22) 520 1/2-inch CL150 ASME B16.5 F304/F304L Lap joint flange N06022 stub 521 1/2-inch CL300 ASME B16.5 F304/F304L Lap joint flange N06022 stub mm 10K JIS B 2220 A105 Lap joint flange N06022 stub 523 DN15 PN40 DIN 2656 F304/F304L Lap joint flange Form C face, N06022 stub 524 DN15 PN40 EN F304/F304L Lap joint flange Type B1, N06022 stub CMFS025M, CMFS040M, and CMFS050M (316L stainless steel) 172 DN25 PN40 EN F316/F316L Weld neck flange Type B1 176 DN15 PN40 EN F316/F316L Weld neck flange Type B1 177 DN15 PN100 EN F316/F316L Weld neck flange Type B2 178 DN15 PN100 EN F316/F316L Weld neck flange Type D mm 10K JIS B 2220 F316/F316L Weld neck flange Raised face mm 20K JIS B 2220 F316/F316L Weld neck flange Raised face 310 DN15 PN40 EN F316/F316L Weld neck flange Type D 313 1/2 CL150 ASME B16.5 F316/F316L Weld neck flange Raised face 314 1/2 CL300 ASME B16.5 F316/F316L Weld neck flange Raised face 315 1/2 CL600 ASME B16.5 F316/F316L Weld neck flange Raised face 319 #8 VCO 316/316L Swagelok compatible fitting 1/2" 316 NPT female adapter 321 1/2 Tri-Clamp compatible 322 3/4 Tri-Clamp compatible ASME BPE 316L Hygienic fitting ASME BPE 316L Hygienic fitting 335 #8 VCO 316/316L Swagelok compatible fitting 336 (1) #12 VCO 316/316L Swagelok compatible fitting 29

30 ELITE Series Coriolis Flow and Density Meters July " Tri-Clamp compatible (1) Only available on model CMFS050. ASME BPE 316L Hygienic fitting CMFS025P and CMFS050P (nickel alloy C22/316L stainless steel) 150 1/2 CL900/1500 ASME B16.5 F316/F316L Weld neck flange Raised face 170 DN15 PN100/160 EN F316/F316L Weld neck flange Type B2 184 DN15 PN250 EN F316/F316L Weld neck flange Type B2 319 #8 VCO 316/316L Swagelok compatible fitting 1/2" 316 NPT female adapter 335 #8 VCO 316/316L Swagelok compatible fitting 336 (1) #12 VCO 316/316L Swagelok compatible fitting (1) Only available on model CMFS050. CMFS075M, CMFS100M, and CMFS150M (316L stainless steel) 179 DN25 PN40 EN F316/F316L Weld neck flange Type B1 180 DN25 PN100 EN F316/F316L Weld neck flange Type B2 181 DN25 PN100 EN F316/F316L Weld neck flange Type D 311 DN25 PN40 EN F316/F316L Weld neck flange Type D 316 DN50 PN40 EN F316/F316L Weld neck flange Type D mm 10K JIS B 2220 F316/F316L Weld neck flange Raised face mm 20K JIS B 2220 F316/F316L Weld neck flange Raised face 322 (1) 3/4 Tri-Clamp compatible ASME BPE 316L Hygienic fitting 328 1" CL150 ASME B16.5 F316/F316L Weld neck flange Raised face 329 1" CL300 ASME B16.5 F316/F316L Weld neck flange Raised face 330 1" CL600 ASME B16.5 F316/F316L Weld neck flange Raised face /2- inch CL600 ASME B16.5 F316/F316L Weld neck flange Raised face 336 (2) #12 VCO 316/316L Swagelok compatible fitting 339 (1) 1" Tri-Clamp compatible /2- inch /2- inch /2- inch 316L Hygienic fitting CL150 ASME B16.5 F316/F316L Weld neck flange Raised face CL300 ASME B16.5 F316/F316L Weld neck flange Raised face Tri-Clamp compatible inch Tri-Clamp compatible ASME BPE 316L Hygienic fitting ASME BPE 316L Hygienic fitting 363 DN40 PN100 EN F316/F316L Weld neck flange Type B2 30

31 July 2017 ELITE Series Coriolis Flow and Density Meters 365 DN50 PN100 EN F316/F316L Weld neck flange Type B2 366 DN40 PN100 EN F316/F316L Weld neck flange Type D 368 DN40 PN40 EN F316/F316L Weld neck flange Type B1 369 DN50 PN40 EN F316/F316L Weld neck flange Type B mm 10K JIS B 2220 F316/F316L Weld neck flange Raised face mm 20K JIS B 2220 F316/F316L Weld neck flange Raised face inch CL150 ASME B16.5 F316/F316L Weld neck flange Raised face inch CL300 ASME B16.5 F316/F316L Weld neck flange Raised face inch CL600 ASME B16.5 F316/F316L Weld neck flange Raised face (1) Not available on model CMFS150. (2) Only available on model CMFS075. CMFS100H and CMFS150H (nickel alloy C22) 530 (1) 1-inch CL150 ASME B16.5 F304/F304L Lap joint flange N06022 stub 531 (1) 1-inch CL300 ASME B16.5 F304/F304L Lap joint flange N06022 stub mm 10K JIS B 2220 F304/F304L Lap joint flange N06022 stub 533 (1) DN25 PN40 DIN 2656 F304/F304L Lap joint flange Form C face, N06022 stub 534 (1) DN25 PN40 EN F304/F304L Lap joint flange Type B1, N06022 stub /2" CL150 ASME B16.5 F304/F304L Lap joint flange N06022 stub /2" CL300 ASME B16.5 F304/F304L Lap joint flange N06022 stub mm 10K JIS B 2220 F304/F304L Lap joint flange N06022 stub 544 2" CL150 ASME B16.5 F304/F304L Lap joint flange N06022 stub 545 2" CL300 ASME B16.5 F304/F304L Lap joint flange N06022 stub mm 10K JIS B 2220 F304/F304L Lap joint flange N06022 stub 549 DN50 PN40 EN F304/F304L Lap joint flange Type B1, N06022 stub (1) Only available on model CMFS100H. CMFS100P and CMFS150P (high pressure) 180 DN25 PN100 EN F316/F316L Weld neck flange Type B2 185 DN25 PN250 EN F316/F316L Weld neck flange Type B2 362 DN40 PN160 EN F316/F316L Weld neck flange Type B2 364 DN40 PN250 EN F316/F316L Weld neck flange Type B2 370 DN50 PN160 EN F316/F316L Weld neck flange Type B2 483 DN50 PN250 EN F316/F316L Weld neck flange Type B2 31

32 ELITE Series Coriolis Flow and Density Meters July 2017 CMF010H, CMF025H, and CMF050H (nickel alloy C22) 323 (1) #4 VCO N06022 Swagelok compatible fitting 1/4 N10276 NPT female adapter 334 (1) #4 VCO N06022 Swagelok compatible fitting 520 1/2-inch CL150 ASME B16.5 F304/F304L Lap joint flange N06022 stub 521 1/2-inch CL300 ASME B16.5 F304/F304L Lap joint flange N06022 stub mm 10K JIS B 2220 F304/F304L Lap joint flange N06022 stub 523 DN15 PN40 DIN 2656 F304/F304L Lap joint flange Form C face, N06022 stub 524 DN15 PN40 EN F304/F304L Lap joint flange Type B1, N06022 stub (1) Only available on model CMF010H. CMF010L, CMF025L, and CMF050L (304L stainless steel) 413 1/2 CL150 ASME B16.5 F304/F304L Weld neck flange Raised face 414 1/2 CL300 ASME B16.5 F304/F304L Weld neck flange Raised face 421 DN15 PN40 EN F304/F304L Weld neck flange Type B1 423 DN15 PN40 DIN 2526 F304/F304L Weld neck flange Form C face CMF010M (316L stainless steel) 172 DN25 PN40 EN F316/F316L Weld neck flange Type B1 176 DN15 PN40 EN F316/F316L Weld neck flange Type B1 177 DN15 PN100 EN F316/F316L Weld neck flange Type B2 178 DN15 PN100 EN F316/F316L Weld neck flange Type D 183 DN25 PN40 EN F316/F316L Weld neck flange Type D 300 DN15 PN40 DIN 2635 F316/F316L Weld neck flange Form C face 302 DN15 PN100 DIN 2637 F316/F316L Weld neck flange Form E face mm 10K JIS B 2220 F316/F316L Weld neck flange Raised face mm 20K JIS B 2220 F316/F316L Weld neck flange Raised face 310 DN15 PN40 EN F316/F316L Weld neck flange Type D 313 1/2" CL150 ASME B16.5 F316/F316L Weld neck flange Raised face 314 1/2" CL300 ASME B16.5 F316/F316L Weld neck flange Raised face 315 1/2" CL600 ASME B16.5 F316/F316L Weld neck flange Raised face 319 #8 VCO 316/316L Swagelok compatible fitting 1/2 316 NPT female adapter 321 1/2" Tri-Clamp compatible 316L Hygienic fitting 323 #4 VCO 316/316L Swagelok compatible fitting 1/4" NPT female adapter 324 #4 VCO 316/316L Swagelok compatible fitting 1/4" tube compression fitting adapter 32

33 July 2017 ELITE Series Coriolis Flow and Density Meters 325 #4 VCO 316/316L Swagelok compatible fitting 6mm tube compression fitting adapter 334 #4 VCO 316/316L Swagelok compatible fitting CMF010P (high pressure) 323 #4 VCO 316/316L Swagelok compatible fitting 1/4 NPT female adapter 324 #4 VCO 316/316L Swagelok compatible fitting 1/4 tube compression fitting adapter 325 #4 VCO 316/316L Swagelok compatible fitting 6mm tube compression fitting adapter 334 #4 VCO 316/316L Swagelok compatible fitting CMF025M (316L stainless steel) 009 1/2 CL150/300 bolt kit ASME B16.5 F316/F316L Wafer style flange 016 DN15 PN40 bolt kit DIN 2526 F316/F316L Wafer style flange Form C face 017 DN15 PN40 bolt kit DIN 2512 F316/F316L Wafer style flange Form N grooved face 018 DN15 PN100 bolt kit 019 DN15 PN100 bolt kit mm 10K/20K bolt kit DIN 2526 F316/F316L Wafer style flange Form E face DIN 2512 F316/F316L Wafer style flange Form N grooved face JIS B 2220 F316/F316L Wafer style flange 172 DN25 PN40 EN F316/F316L Weld neck flange Type B1 176 DN15 PN40 EN F316/F316L Weld neck flange Type B1 177 DN15 PN100 EN F316/F316L Weld neck flange Type B2 178 DN15 PN100 EN F316/F316L Weld neck flange Type D 183 DN25 PN40 EN F316/F316L Weld neck flange Type D 300 DN15 PN40 DIN 2635 F316/F316L Weld neck flange Form C face 301 DN15 PN40 DIN 2635 F316/F316L Weld neck flange Form N grooved face 302 DN15 PN100 DIN 2637 F316/F316L Weld neck flange Form E face 303 DN15 PN100 DIN 2637 F316/F316L Weld neck flange Form N grooved face mm 10K JIS B 2220 F316/F316L Weld neck flange Raised face mm 20K JIS B 2220 F316/F316L Weld neck flange Raised face 310 DN15 PN40 EN F316/F316L Weld neck flange Type D 313 1/2 CL150 ASME B16.5 F316/F316L Weld neck flange Raised face 314 1/2 CL300 ASME B16.5 F316/F316L Weld neck flange Raised face 315 1/2 CL600 ASME B16.5 F316/F316L Weld neck flange Raised face 319 #8 VCO 316/316L Swagelok compatible fitting 1/2" NPT female adapter 33

Micro Motion ELITE Coriolis Flow and Density Meters

Micro Motion ELITE Coriolis Flow and Density Meters Micro Motion ELITE Coriolis Flow and Density Meters Product Data Sheet PS-00374, Rev AG June 2018 Ultimate real world performance Unchallengeable ELITE performance on liquid mass flow, volume flow, and

More information

Micro Motion ELITE Coriolis Flow and Density Meters

Micro Motion ELITE Coriolis Flow and Density Meters Micro Motion ELITE Coriolis Flow and Density Meters Product Data Sheet PS-00374, Rev V April 2013 Ultimate real world performance Unchallengeable ELITE performance on liquid mass flow, volume flow, and

More information

Micro Motion ELITE Coriolis Flow and Density Meters

Micro Motion ELITE Coriolis Flow and Density Meters Micro Motion ELITE Coriolis Flow and Density Meters Product Data Sheet PS-00374, Rev AH December 2018 Ultimate real world performance Unchallengeable ELITE performance on liquid mass flow, volume flow,

More information

Micro Motion F-Series Flow and Density Meters

Micro Motion F-Series Flow and Density Meters Product Data Sheet PS-00603, Rev AB January 2019 Micro Motion F-Series Flow and Density Meters High accuracy real world performance Best-in-class performance on liquid mass flow, volume flow, and density

More information

Micro Motion F-Series Flow and Density Meters

Micro Motion F-Series Flow and Density Meters Micro Motion F-Series Flow and Density Meters Product Data Sheet PS-00603, Rev Z December 2017 High accuracy real world performance Best-in-class performance on liquid mass flow, volume flow, and density

More information

Micro Motion F-Series Coriolis Flow and Density Meters

Micro Motion F-Series Coriolis Flow and Density Meters Product Data Sheet PS-00603, Rev. F December 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density

More information

Micro Motion R-Series Coriolis Flow and Density Meters

Micro Motion R-Series Coriolis Flow and Density Meters Micro Motion R-Series Coriolis Flow and Density Meters Product Data Sheet PS-00363, Rev N June 2018 Multi-variable flow and density measurement Basic liquid mass flow, volume flow, and density measurement

More information

Micro Motion T-Series Coriolis Flow and Density Meters

Micro Motion T-Series Coriolis Flow and Density Meters Micro Motion T-Series Coriolis Flow and Density Meters Product Data Sheet PS-00371, Rev K April 2018 Superior flow measurement in a single straight tube flow meter Built-in balance bar provides the best

More information

Micro Motion Technical Overview and Specification Summary

Micro Motion Technical Overview and Specification Summary Product Data Sheet PS-00232, Rev. J June 2009 Micro Motion Technical Overview and Specification Summary Emerson s world-leading Micro Motion Coriolis flow and density measurement devices have set the standard

More information

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Product Data Sheet PS-001041, Rev. F February 2010 Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Micro Motion ELITE High Capacity Coriolis meters offer unparalleled flow and density

More information

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Product Data Sheet PS-001041, Rev. L April 2013 Micro Motion ELITE High Capacity Coriolis Flow and Density Meters Micro Motion ELITE High Capacity Coriolis meters offer unparalleled flow and density measurement

More information

Micro Motion Model D and DL Coriolis Flow and Density Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,

More information

Micro Motion F-Series Coriolis Flow and Density Meters

Micro Motion F-Series Coriolis Flow and Density Meters Product Data Sheet PS-00629, Rev. E May 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density measurement

More information

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters Product Data Sheet PS-00408, Rev. D April 2011 Micro Motion Model CNG050 Compressed Natural Gas Flowmeters Micro Motion Model CNG050 meters are specifically designed for the CNG industry to meet the challenges

More information

Micro Motion ELITE Mass Flow and Density Meters

Micro Motion ELITE Mass Flow and Density Meters Product Data Sheet PS 00374, Rev. A July 2003 Micro Motion ELITE Mass Flow and Density Meters Available with MVD Technology! TM Micro Motion Micro Motion ELITE mass flow and density meters Experience the

More information

Micro Motion ELITE Mass Flow and Density Meters

Micro Motion ELITE Mass Flow and Density Meters Product Data Sheet PS 00375 March 2002 Micro Motion ELITE Mass Flow and Density Meters Now available with MVD Technology! www.micromotion.com Micro Motion ELITE Meters Experience the most accurate Coriolis

More information

Now available with MVD Technology! ELITE Mass Flow and Density Meters

Now available with MVD Technology! ELITE Mass Flow and Density Meters Product Data Sheet PS-00374 July 2001 Now available with MVD Technology! ELITE Mass Flow and Density Meters Micro Motion ELITE Meters Experience the most accurate Coriolis meters available today. Micro

More information

Technical Data Sheet PS , Rev C May Micro Motion R-Series Coriolis Flow and Density Meters

Technical Data Sheet PS , Rev C May Micro Motion R-Series Coriolis Flow and Density Meters Technical Data Sheet PS-001945, Rev C May 2017 Micro Motion R-Series Coriolis Flow and Density Meters R-Series Coriolis Flow Meters May 2017 Detailed Specifications R-Series accuracy Model Liquid mass

More information

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001 Micro Motion T-Series Straight-Tube Mass Flow and Density Meters Product Data Sheet PS-00371 July 2001 Micro Motion T-Series Straight-Tube Meters Micro Motion is proud to offer you the first single-straight-tube

More information

OPTIMASS 3000 Technical Datasheet

OPTIMASS 3000 Technical Datasheet OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless

More information

OPTIMASS 2000 Technical Datasheet

OPTIMASS 2000 Technical Datasheet OPTIMASS 2000 Technical Datasheet Sensor for bulk mass flow Large diameter for bulk measurement and custody transfer of liquids and gases Stainless Steel measuring tubes (NACE Compliant) Modular electronics

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Effective separation of measurement from plant vibration Reliable measurements due to high signal to noise ratio

More information

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters Product Data Sheet PS-00408, Rev. C February 2008 Micro Motion Model CNG050 Compressed Natural Gas Flowmeters Micro Motion Model CNG050 meters are specifically designed for the CNG industry to meet the

More information

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

VersaFlow Coriolis 100 Mass Flow Sensor Specifications VersaFlow Coriolis 100 Mass Flow Sensor Specifications 34-VF-03-09 May 2011 The Universal Solution for the Process Industry VERSAFLOW is the only sensor for mass flow in its class with secondary pressure

More information

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors. Product Data Sheet PS 00388 February 2002 Model D and DT Mass Flow and Density Sensors www.micromotion.com Model D and DT sensors Micro Motion Model D sensors set the standard for Coriolis flowmeters nearly

More information

LCMass Series Mass Flow Sensor

LCMass Series Mass Flow Sensor LCMass 100-140 Series Mass Flow Sensor Technical Data Sheet HIGH ACCURACY The LCMass 100 achieves a ±0.15% accuracy on liquids. COMPACT ECONOMIC DESIGN Straight twin-tube design allows for an overall smaller

More information

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel KROHNE 04/2004 7.02445.24.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel Status: 10/99 Status: 10/99 One tube no limits No limits with

More information

OPTIGAS 4010C Technical Datasheet

OPTIGAS 4010C Technical Datasheet OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation

More information

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits RHM40 Coriolis Mass Flow Meter for Demanding Applications Features Standard pressure ratings up to 433 bar (6280 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to

More information

Promass Q for the process industry

Promass Q for the process industry Products Solutions Services Promass Q for the process industry A unique Coriolis innovation from Endress+Hauser Slide 1 Promass Q for the process industry Promass Q Design Coriolis flowmeter Available

More information

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits RHM30 Coriolis Mass Flow Meter for Plant and Loading Flows Features Standard pressure ratings up to 798 bar (11574 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down

More information

OPTIGAS 4010C Technical Datasheet

OPTIGAS 4010C Technical Datasheet OPTIGAS 4010C Technical Datasheet Sensor for gas dispenser applications Compact design for easy istallation High accuracy with wide measuring range Designed to fit existing dispensers The documentation

More information

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM08. Versatile Coriolis Mass Flow Meter. Features. Applications. Benefits RHM08 Versatile Coriolis Mass Flow Meter Features Standard pressure ratings up to 1254 bar (18188 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.10% Repeatability

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R 117 (Liquids other than water)

More information

REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY

REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY Micro Motion Gas Density Meter INTRODUCING EMERSON S MICRO MOTION GAS DENSITY METER Our Gas Density Meter (GDM) delivers fast-response online

More information

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits

RHM015. Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications. Features. Applications. Benefits RHM015 Ultimate Performance Coriolis Mass Flow Meter for Critical Ultra Low Flow Applications Features Standard pressure ratings up to 752 bar (10907 psi) Temperature ratings from -196 to 350 C (-320 to

More information

Micro Motion 7827 Digital Viscosity Meter

Micro Motion 7827 Digital Viscosity Meter Product Data Sheet PS-001217, Rev. C April 2013 Micro Motion 7827 Digital Viscosity Meter Micro Motion viscosity meters are built to tackle the most demanding process and control applications. Rugged and

More information

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors RHM 015L/02L/03L/04L Compact Low Flow Coriolis Flow Sensors Features Pressure ratings up to 20000 psi / 1379 bar Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty less than 0.10%

More information

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors

RHM 015L/02L/03L/04L. Compact Low Flow Coriolis Flow Sensors RHM 015L/02L/03L/04L Compact Low Flow Coriolis Flow Sensors Features Pressure ratings up to 20000 psi / 1379 bar Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty less than 0.10%

More information

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits

RHM04. Compact Coriolis Flow Sensor With Enhanced Performance. Features. Applications. Benefits RHM04 Compact Coriolis Flow Sensor With Enhanced Performance Features Standard high pressure versions up to 1067 bar (15475 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C verview The flow measuring principle is based on the Coriolis Effect. The FCS400 sensor s measuring tubes are energized by an electromechanical driver circuit which oscillates them at their resonance frequency.

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.

More information

SITRANS FC. Flowmeter SITRANS FC410

SITRANS FC. Flowmeter SITRANS FC410 Siemens AG 2013 Flow Measurement Overview The Coriolis flowmeter 410 consists of a SITRANS FCS400 sensor and a T010 transmitter, always compact mounted. It is based on the latest developments within digital

More information

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview Siemens G 2009 SITRNS flowmeters SITRNS C SITRNS C MC2 Overview SITRNS C MC2 is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG-certified version (DN 20 to DN (¾ to 3

More information

SITRANS F flowmeters SITRANS F C

SITRANS F flowmeters SITRANS F C SITRNS F flowmeters Siemens G 2008 Overview is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG certified version (DN 20 to DN 80 (¾ to 3 )). MC2 and MC2 hygienic are suitable

More information

Ultimate Low Flow Coriolis Mass Flowmeter

Ultimate Low Flow Coriolis Mass Flowmeter RHM 015 - Ultimate Low Flow Coriolis Mass Flowmeter The RHM 015 can reliably measure flow rates as low as 1 g/min (0.002 lb/min). With its extremely wide turn-down ratio of 300 to 1, this model is perfect

More information

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter RHM 12 - Standard 1 inch Coriolis Mass Flowmeter The RHM 12 can measure flow rates up to 100 kg/min with temperatures in excess of 400 C and pressures up to 290 bar. This model is truly a versatile solution,

More information

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response The RHM 04 can measure flow rates up to 10 kg/min (21 lb/min) with extremely fast response times and excellent repeatability. A

More information

SITRANS F C. Flow sensor MC2 4/193. Overview

SITRANS F C. Flow sensor MC2 4/193. Overview Siemens G 2011 low Measurement SITNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals,

More information

Coriolis Mass Flowmeter for low flow measurements

Coriolis Mass Flowmeter for low flow measurements RHM 03 - Flexible Coriolis Mass Flowmeter for low flow measurements The RHM 03 can measure flow rates up to 5 kg/min (11 lb/min) with temperatures in excess of 400 C and pressures to 868 bar. This model

More information

Installation Manual , Rev CG January Micro Motion F-Series Coriolis Flow and Density Sensors

Installation Manual , Rev CG January Micro Motion F-Series Coriolis Flow and Density Sensors 20002298, Rev CG January 2019 Micro Motion F-Series Coriolis Flow and Density Sensors Safety and approval information This Micro Motion product complies with all applicable European directives when properly

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Micro Motion F-Series Coriolis Flow and Density Sensors. Installation Manual , Rev CF January 2018

Micro Motion F-Series Coriolis Flow and Density Sensors. Installation Manual , Rev CF January 2018 Micro Motion F-Series Coriolis Flow and Density Sensors Installation Manual 20002298, Rev CF January 2018 Safety and approval information This Micro Motion product complies with all applicable European

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Coriolis Flow Solutions for a Global Marketplace

Coriolis Flow Solutions for a Global Marketplace Coriolis Flow Solutions for a Global Marketplace www.tricorflow.com DECADES of EXPERIENCE = EXCEPTIONAL RESULTS When you combine decades of experience with truly unique talents, great things can happen.

More information

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry KROHNE 10/02 7.02444.21.00 GR Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry Optimass One Tube... Optimass is a brand new family of Coriolis mass flowmeters from

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

Coriolis Flow Solutions for a Global Marketplace

Coriolis Flow Solutions for a Global Marketplace Coriolis Flow Solutions for a Global Marketplace www.tricorflow.com DECADES of EXPERIENCE = EXCEPTIONAL RESULTS When you combine decades of experience with truly unique talents, great things can happen.

More information

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI Siemens AG Flow sensor MASS DI 3 to DI 0 Overview MASS DI 3 to DI 0 is suitable for accurate mass flow measurement of a variety of liquids and gases. The sensor offers superior performance in terms of

More information

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: Rosemount 1810 Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: A cleanable and compact stainless steel design An innovative patented venting configuration that prevents gauge reference

More information

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling

RHM 03 a1 - (low stress in welds and increased wall thickness against abrasion) RHM bar APPLICATIONS. Batching Dosing. Injections Filling RHM 03 a1 - RHM 03 0.05 ~ 5 kg/min (11 lb/min), -200 ~ 400 C, APPLICATIONS Batching Dosing Injections Filling FEATURES 868 bar 0.005 kg/min ~ 5 kg/min (11 lb/min) 0.1% 0.05% process connection. ADVANTAGES

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

RHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages

RHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages RHM 04 Universal Coriolis Mass Flowmeter with particular Fast Response The RHM 04 can measure flow rates up to 10 kg/min (22 lb/min) with extremely fast response times and excellent repeatability. A true

More information

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry KROHNE 10/02 7.02443.21.00 GR Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry Optimass One Tube... Optimass is a brand new family of Coriolis mass flowmeters from KROHNE.

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26 Electronic Pressure Measurement Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26 WIKA Datasheet WU-2X Applications Gas panels for OEM tools Semiconductor, flat panel display and photovoltaic

More information

RHM 015. Ultimate Low Flow Coriolis Mass Flowmeter. Applications. Features. Advantages

RHM 015. Ultimate Low Flow Coriolis Mass Flowmeter. Applications. Features. Advantages RHM 015 Ultimate Low Flow Coriolis Mass Flowmeter The RHM 015 can reliably measure flow rates as low as 1 g/min (0.002 lb/min). With its extremely wide turn-down ratio of 300 to 1, this model is perfect

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

HTM Series Helical Turbine Meters

HTM Series Helical Turbine Meters HTM Series Helical Turbine Meters The HTM series of turbine meters is designed for high accuracy volume measurement of crude oils and other liquid hydrocarbons. M&T helical turbine meters are preferred

More information

RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages

RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages RHM 03 Flexible Coriolis Mass Flowmeter for low flow measurements The RHM 03 can measure flow rates up to 5 kg/min (11 lb/min) with temperatures in excess of 400 C and pressures to 868 bar. This model

More information

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Pressure transmitter for marine applications MBS 3100 and MBS 3150 Data sheet Pressure transmitter for marine applications MBS 3100 and MBS 3150 The compact ship approved pressure transmitters MBS 3100 and MBS 3150 are designed for use in almost all marine applications.

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

Rosemount 3051T In-Line Pressure Transmitter

Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-line Pressure Transmitters are the industry standard for Gage, and Absolute pressure measurement. The in-line, compact design allows the

More information

SITRANS F M. Flow sensor MAG 1100 F 3/59

SITRANS F M. Flow sensor MAG 1100 F 3/59 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) is suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Siemens G 2014 SITRNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals, acids, alkalis

More information

Pressure transmitter for marine applications MBS 33M

Pressure transmitter for marine applications MBS 33M Data sheet Pressure transmitter for marine applications MBS 33M The standard pressure transmitter MBS 33M is designed for use in almost all marine applications, and offers a reliable pressure measurement,

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS Features/Benefits INSTALL IT & FORGET IT The ForceMeter TM offers the same rugged design for which the Niagara Meters brand is known. The ForceMeter is ideal for applications including water, compressed

More information

Rosemount DP Flowmeters and Primary Elements

Rosemount DP Flowmeters and Primary Elements meters and Primary Elements Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated Wireless Flowmeters allow for easy installation Minimize permanent pressure

More information

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the

More information

BARTON 7400 Precision Gas Turbine Flow Meters

BARTON 7400 Precision Gas Turbine Flow Meters TECHNICAL SPECIFICATIONS BARTON 7400 Precision Gas Turbine Flow Meters BARTON Model 7400 Precision Turbine Flow Meters are designed for gas service in a wide range of industrial, commercial, pipeline and

More information

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter INTERPLANT STANDARD - STEEL INDUSTRY IPSS Specification for Smart Pressure & Differential Pressure Transmitter Corresponding IS does not exist IPSS: 2-07-104-15 1. Scope 1.1 This Interplant Standard covers

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

RHM 08. One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications. Applications. Advantages.

RHM 08. One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications. Applications. Advantages. RHM 08 One of the most popular Rheonik Mass Flowmeter serving thousands of worldwide applications The RHM 08 can measure flow rates up to 50 kg/min (110 lb/min) with temperatures in excess of 350 C and

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Pressure transmitter for marine applications Type MBS 5100 and MBS 5150

Pressure transmitter for marine applications Type MBS 5100 and MBS 5150 Data sheet Pressure transmitter for marine applications Type MBS 5100 and MBS 5150 The ship approved high accuracy block pressure transmitter is designed for use in almost all marine applications. MBS

More information

Ultra High Purity Transducer, Ex na ic Models WUC-10, WUC-15 and WUC-16

Ultra High Purity Transducer, Ex na ic Models WUC-10, WUC-15 and WUC-16 Electronic Pressure Measurement Ultra High Purity Transducer, Ex na ic Models WUC-10, WUC-15 and WUC-16 WIKA Datasheet WUC-1X Applications Semiconductor, flat panel display and photovoltaic industry Specialty

More information

Micro Motion F-Series Coriolis Flow and Density Sensors. Installation Manual , Rev CC December 2010

Micro Motion F-Series Coriolis Flow and Density Sensors. Installation Manual , Rev CC December 2010 Micro Motion F-Series Coriolis Flow and Density Sensors Installation Manual 20002298, Rev CC December 2010 Safety and approval information This Micro Motion product complies with all applicable European

More information

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing KROHNE 10/02 7.02442.21.00 GR Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing Optimass One Tube... Optimass is a brand new family of Coriolis mass flowmeters from KROHNE.

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

RHM 06. One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications. Applications. Advantages.

RHM 06. One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications. Applications. Advantages. RHM 06 One of the Most Popular Rheonik Mass Flowmeter Serving Thousands of Worldwide Applications The RHM 06 can measure flow rates up to 25 kg/min (55 lb/min) with temperatures in excess of 350 C and

More information