Safeguarding Applications and Wiring Diagrams Cat 1 Stop with Guardlocking Interlock and Proximity Sensors TLSZR-GD2, 872C, GLP, PowerFlex 45

Size: px
Start display at page:

Download "Safeguarding Applications and Wiring Diagrams Cat 1 Stop with Guardlocking Interlock and Proximity Sensors TLSZR-GD2, 872C, GLP, PowerFlex 45"

Transcription

1 Cat with Guardlocking Interlock and TLSZ-GD, C,, PowerFlex 5 + VDC eset & Lock PowerFlex 5 LL L Brown ed Yellow Green Grey Pink White Blue TLSZ-GD D-FAC- X X 5 S5 S Y 6 -GLSP S S L5 5 A P P AX L Gnd S S control power supply control circuit C-DNP-D D-FAC- V DC Com The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Category with Logic IN OFF), a Safe Limited Speed (SLS) setting of (Hz) and a aximum speed setting of (Hz). The safety outputs (X & X), the single wire safety output (L) and the auxiliary output (Y) are OFF. NOTE: the logic configuration from to configure X and X for use as safety outputs. STATING: Press the reset button to lock the gate and turn the safety outputs ON. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns OFF and initiates a stop command to the drive. When the speed detected by the proximity sensors drops below the safe limited speed, the gate becomes unlocked and the safety outputs turn OFF. The PowerFlex drive goes to a safe off state. If the motor has not already stopped, the motor coasts to a stop. OVESPEED: If the proximity sensors detect a speed greater than the maximum speed (Hz), the auxiliary output (Y), the safety outputs (X & X) and the single wire safety output (L) turn off. The PW/Fault indicator flashes at a X rate. When the speed drops below the max speed limit, press the eset button to clear the fault. Upon power-up, the safety devices perform internal checks. The TLSZ has OSSD outputs and checks for crossfaults. The safety outputs are pulse tested to check for faults. The proximity sensors are continuously tested by requiring that both sensors cannot be OFF at the same time. The PowerFlex 5 performs its own internal safety checks, and requires two safety signals to enable the drive. atings The safety function meets the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Category stop. - -

2 + VDC Safeguarding Applications and Wiring Diagrams Cat with Guardlocking Interlock and TLS-GD, C,, PowerFlex eset & Lock L L L S T PowerFlex X X 5 S5 S Y L A 5 5 -GLSP S S L5 A P P AX L DC Comm Digital In Com TLS GD G-T Status C-DNP-D D-FAC- emove Jumper U V W V DC Com The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Category with Logic IN OFF), a Safe Limited Speed (SLS) setting of (Hz) and a aximum speed setting of (Hz). The safety outputs (X & X), the single wire safety output (L) and the auxiliary output (Y) are OFF. NOTE: the logic configuration from to configure X and X for use as safety outputs. STATING: Press the eset button to lock the gate and turn the safety outputs ON. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns OFF and initiates a stop command to the drive. When the speed detected by the proximity sensors drops below the safe limited speed, the gate becomes unlocked and the safety outputs turn OFF. The PowerFlex drive goes to a safe off state. If the motor has not already stopped, the motor coasts to a stop. OVESPEED: If the proximity sensors detect a speed greater than the maximum speed (Hz), the auxiliary output (Y), the safety outputs (X & X) and the single wire safety output (L) turn off. The PW/Fault indicator flashes at a X rate. When the speed drops below the max speed limit, press the eset button to clear the fault and energize the safety outputs. Upon power-up, the safety devices perform internal checks. The TLS has dual channel signals but does not checks for crossfaults. The safety outputs are pulse tested to check for faults. The proximity sensors are continuously tested by requiring that both sensors cannot be OFF at the same time. The PowerFlex requires two safety signals to enable the drive. atings The safety function meets the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Category stop. - -

3 Category with Guardlocking Interlock and TLS-GD, F, C,, DIS, PowerFlex + VDC L L L eset & Lock F-TXV PowerFlex S T E- A 5 5 X X 5 S5 S Y L -GLSP S S 5 A AX P P L S S S S S S Y DIS -DS L L A S Status eset DC Comm Digital In Com TLS GD G-T Status C-NP-D D-FAC- emove Jumper U V W V DC Com The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Cat with Logic IN OFF), a Safe Limited Speed (SLS) setting of ( Hz) and a maximum (AX) speed setting of ( Hz). Both E-s are closed. The DI is configured to setting [(IN AND IN) AND L] with monitored manual reset). NOTE: the logic configuration from to configure X and X for use with safety inputs. STATING: Press the eset button to turn the safety output (L) ON. This enables the DI relay. Press the eset button to turn the DI outputs ON and enable the Safe-Off Option of the PowerFlex Drive. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns OFF and initiates a stop command to the drive. When the motor speed drops below the safe limited speed, the unlocks the gate and turns its L safety output OFF. Subsequently the DI turns its safety outputs off, and the PowerFlex drive goes to a Safe-Off state. The motor, if not already stopped, coasts to a stop. The E-stop buttons can be used to initiate a coast-to-stop. Press the e-stop and the DI outputs turn off, which causes teh PowerFlex drive to execute a Safe-Off function. The motor coasts to a stop. Upon power-up, the safety devices perform internal checks. The sends out test pulses on X & X to check for faults on the guardlocking switch. The DI sends out test pulses on S & S to check for faults on the e-stops. The checks to see that the proximiity senors are connected, by requiring that both sensors cannot be OFF at the same time. The L/L connection is Single Wire connection tested for shorts to power or ground when active. The DIS outputs & are pulse tested to check for shorts to power and ground. The DIS outputs &, which are not pulse tested, should be used for compatibility with devices that cannot tolerate the pulse testing. atings The safety functions meet the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Category stop when requesting gate access through the, and a Category stop when pressing the e-stops. - -

4 Safe Limited Speed with Guardlocking Interlock and TLSZ-GD, T,, PowerFlex + VDC L L L eset & Lock PowerFlex VDC S T V DC Com Brown ed Yellow Green Grey Pink White Blue TLSZ-GD D-FAC- X X 5 -GLSP S S L5 S5 S Y A P P L AX L T-DHNP-D D-FAC- Speed Select DC Comm Digital In Com emove Jumper U V W The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Safe Limited Speed with Logic IN OFF), a Safe Limited Speed (SLS) setting of 5 (5Hz) and a aximum speed setting of (Hz). The safety outputs (S & S), the single wire safety output (L) and the auxiliary output (Y) are OFF. NOTE: the logic configuration from to configure X and X for use as safety outputs. STATING: Press the eset button to turn the safety outputs and single wire safety output ON. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns ON and commands the PowerFlex drive to bring the motor to a safe slow speed (less than 5Hz). When the speed detected by the proximity sensors drops below the safe limited speed (5Hz), the gate becomes unlocked. The operator can enter the machine cell, as the motor continues to run at the safe slow speed. After leaving the cell and closing the gate, press the reset button to lock the gate and return the machine to production speeds. Upon power-up, the safety devices perform internal checks. The TLSZ has OSSD outputs and checks for crossfaults. The safety outputs are pulse tested to check for faults. The proximity sensors are continuously tested by requiring that both sensors cannot be OFF at the same time. The PowerFlex requires two safety signals to enable the drive. If the gate is unlocked and the motor speed increases beyond the safe limited speed, the turns its safety and single wire safety outputs OFF. OVESPEED: If the proximity sensors detect a speed greater than the maximum speed (Hz), the safety and the single wire safety outputs turn OFF. The PW/Fault indicator flashes at a X rate. When the speed drops below the max speed limit, press the eset button to clear the fault. atings The safety function meets the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Safe Limited Speed function. - -

5 Safe Limited Speed with Guardlocking Interlock and TLS-GD, F, C,, DI, PowerFlex 5 + VDC eset & Lock E- F-T F-XS eset PowerFlex 5 +V DC L L L A 5 5 X X 5 S5 S Y L -GLSP S S 5 A AX P P L S S S S DI -D S S L L A S Y Dig Input (Speed Select) Gnd control power supply control circuit S V DC Com TLS GD G-T Status C-DNP-D D-FAC- Status S The gate is closed and locked. The motor is off. The is ready for reset. The has a Logic setting of : (Safe Limited Speed with Logic IN OFF), a Safe Limited Speed (SLS) setting of ( Hz) and a maximum (AX) speed setting of ( Hz). Both E-s are closed. The DI is configured to setting [(IN AND IN) AND L] with monitored manual reset. The single wire safety output (L) and the auxiliary output (Y) are OFF. The DI safety outputs are off and the DI auxiliary output (Y) is ON. NOTE: the logic configuration from to configure X and X for use with safety inputs. STATING: Press the eset button to turn the safety outputs (L) ON. This enables the DI relay. Press the eset button to turn the DI outputs ON and enable the PowerFlex Drive. Press the button to turn the motor ON. STOPPING: Normal production stopping is performed by pressing the button. Access through the safety gate is initiated by pressing the button. The Y output of the turns ON and commands the PowerFlex drive to bring the motor to a safe slow speed (less than Hz). When the speed detected by the proximity sensors drops below the safe limited speed (Hz), the gate becomes unlocked. The operator can enter the machine cell, as the motor continues to run at the safe slow speed. After leaving the cell and closing the gate, press the reset button to lock the gate and return the machine to production speeds. The E-stop buttons can be used to initiate a coast-to-stop. Press the e-stop and the DI outputs turn off, which commands the drive to a safe off state. The motor coasts to a stop. Upon power-up, the safety devices perform internal checks. The sends out test pulses on X and X to check for faults on the guardlocking switch. The DI sends out test pulses on S and S to check for faults on the e-stops. The checks to see that the proximiity senors are connected, by requiring that both sensors cannot be OFF at the same time. The L/L connection is Single Wire connection tested for shorts to power or ground when active. atings The safety functions meet the safety performance requirements of SIL CL per IEC 66:5 and has a Category structure that can be used in systems requiring Performance Levels up to PLd per ISO-:. This circuit executes a Safe Limited Speed function when requesting gate access through the, and a Category stop when pressing the e-stops

Safety Application Note

Safety Application Note Safety Application Note Safety Application Note Rockwell Automation A Modular Safety System Design Concept Gobal E-Stop with Local Machine Guarding This application note shows a modular safety design concept

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Power Supply Safety Guard Locking Atlas 5 General 1-2-Opto-electronics 3-Interlock Logic Description The Atlas 5 is a positive-mode, tongue-operated guard-locking interlock switch that locks a machine guard closed

More information

3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT

3-36. General 1-2-Opto-electronics 3-Interlock. Switches. Operator. Interface. Logic Power. Safety Switches Guard Locking Switches 440G-MT Safety Guard Locking 440G-MT General 1-2-Opto-electronics 3-Interlock Logic Description The 440G-MT solenoid switch is a positive mode, tongue operated guard locking interlock switch that locks a machine

More information

Palletiser Functional Safety Specification

Palletiser Functional Safety Specification Palletiser Functional Specification R Non-muted Light Curtain (generally in-feed conveyor), pages 6...7 +V DC * L-PSxxxxYD Power/ Fault Reset 800F-F6 800F-AL Auto Signal To PLC Start/Restart 800F-F8 800F-AL

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Locking Type. Power Supply. Operating Radius, Min Safety Guard Locking TLS- General 1-2-Opto-electronics 3-Interlock Logic Description The TLS- is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS Door Monitoring Trojan 5 Interlock Switch, Guardmaster Safety Relay, PowerFlex 525 Drive with Safe Torque-off Table of Contents: Introduction 6-122

More information

Safety Control HR1S-AC. Safety Relay HR1S-AC

Safety Control HR1S-AC. Safety Relay HR1S-AC HRS-AC Safety Relay HRS-AC Key features: NC or 2NC safety input type, such as E-Stops or Interlock Switches EN ISO 3849- PLe, Safety Cat 3 compliant, and EN 6206 SIL 3 Fault diagnosis function with dual

More information

APPLICATIONS. The SAFEasy TM SG2 light curtains represent the natural evolution of the

APPLICATIONS. The SAFEasy TM SG2 light curtains represent the natural evolution of the safety presence control LIGHT CURTAINS SG-presence control SERIES The SAFEasy TM SG light curtains represent the natural evolution of the SF series. The SG series offers two models, SG-B Base and SG-E

More information

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics Table of Contents Emergency Cable Pull Switches Operator Interface Overview...4-2 LIfeline ope Tensioner System (LTS)...4-4 Lifeline 3...4-6 Lifeline 4...4-10 Lifeline 4 Stainless Steel...4-16 Enabling

More information

APPLICATIONS. Automatic assembling lines Palletizers and Depalletizers

APPLICATIONS. Automatic assembling lines Palletizers and Depalletizers safety BODY PROTECTION LIGHT CURTAINS SG BODY COMPACT SERIES SG BODY COMPACT is the new family of Datalogic Automation Type 2 and Type 4 safety light curtains for body protection and access control able

More information

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No. Fixed. Block Diagram Y41 MSR30RT/RTP

Inputs Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. No. Fixed. Block Diagram Y41 MSR30RT/RTP Single-Function Relays SR30RT/RTP s Auxiliary s Terminals Type Supply 1 N.C., 2 N.C. 2 N.O. Solid State 1 N.O. Solid State Fixed Auto./anual or 24V DC SELV 440R-N23197 onitored anual 24V DC 440R-N23198

More information

Sequential logic implementation

Sequential logic implementation Sequential logic implementation Implementation random logic gates and FFs programmable logic devices (PAL with FFs) Design procedure state diagrams state transition table state assignment next state functions

More information

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

Specifications. Standards. Category. Certifications. Power Supply. Connection Wire Length, Max. Detection Weight. Wire Size

Specifications. Standards. Category. Certifications. Power Supply. Connection Wire Length, Max. Detection Weight. Wire Size General 1-Principles 2-Safety s 3-Safety Switches 4-Operator The Guard safety mat is a pressure-sensitive safeguarding product that is designed to detect the presence of people on its sensing surface.

More information

Safety Exhaust Valve Integration Guide

Safety Exhaust Valve Integration Guide Safety Exhaust Valve Integration Guide FRL-SIF-625 the total systems approach to air preparation Table of Contents Integration Guide Wilkerson E28/Q28 Safety Exhaust Valve General Information Introduction......

More information

Welcome to the presentation about safety functions of ACS880 functional safety, FSO- 12 Safety functions module.

Welcome to the presentation about safety functions of ACS880 functional safety, FSO- 12 Safety functions module. Welcome to the presentation about safety functions of ACS880 functional safety, FSO- 12 Safety functions module. 1 Here is a list of the FSO-12 supported safety functions and example applications they

More information

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics

Operator Interface 4-1. General. Safety Switches. 4-Table of. Contents. Logic. Power. Operator Interface Table of Contents. 2-Opto-electronics Table of Contents Emergency Operator Interface Overview...4-2 LIfeline ope Tensioner System (LTS)...4-4 Lifeline 3...4-6 Lifeline 4...4-10 Lifeline 4 Stainless Steel...4-16 Enabling Switches GripSwitch...4-24

More information

IDEM Solenoid Interlock Safety Switches

IDEM Solenoid Interlock Safety Switches KLP/KLM/KL3-SS Series Housing Solenoid locking, tongue (key) interlock operated Power to unlock 90 degree adjustable head One (KLP) or three (KLM, KL3-SS) 1/2 in. female NPT conduit opening 30mm mounting

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power SEFTEST 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with self-test function For self-contained emergency lighting SEV for output voltage

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Auxiliary Contacts. Actuation Speed, Max.

Specifications. Safety Ratings. Standards. Safety Classification. Certifications. Safety Contacts. Auxiliary Contacts. Actuation Speed, Max. AUDIN - 8, avenue de la malle - 70 Saint Brice Courcelles - Tel : 0.6.0.0. - Fax : 0.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr 80T Direct Opening Action Description The 80T Direct Opening

More information

Possible to create the highest level safety system

Possible to create the highest level safety system 14 LIGHT CURTAIS (For PP output type light curtain) Control category 4 Possible to create the highest level safety system Conforming to achine Directive & C Directive Approved Listing Compatible up to

More information

Safety Sensor CSS 180 Product Information

Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in

More information

FS1A Safety Controller

FS1A Safety Controller Complies with key safety standards In Human Machine Interface (HMI) environment, ensuring the safety of operators and machines is given the top priority. Enabling switches, emergency stop switches, light

More information

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information Segment Terminal Fused, with Diagnostics 24VDC Segment Terminal module is used to create a protected partial circuit (segment circuit) within the main circuit. It is not used to supply power and has no

More information

Note: Read this manual carefully before installing the operator and place this installation manual in an accessible place near the operator.

Note: Read this manual carefully before installing the operator and place this installation manual in an accessible place near the operator. Installation & Instruction Manual Electronic Control Board (ECB) Note: Read this manual carefully before installing the operator and place this installation manual in an accessible place near the operator.

More information

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve) Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

FT-10 Network Digital I/O Module Kits and

FT-10 Network Digital I/O Module Kits and Instruction Sheet 10-2004 FT-10 Network Digital I/O Module Kits 541 0771 and 541 0772 PURPOSE OF KIT The Digital I/O Module (DIM) makes provisions for a group of relay contact outputs and discrete inputs

More information

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: SECTION 6 Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION: 70 Application: IDEM Universal Gate Boxes (UGB-KLT) provide high level RFID coded interlocking and machine control

More information

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC AZM 00,,,,, M0x1, 0 1, AZM 00➀-T-➁➂ 0 1 Solenoid interlock (Solenoid interlock monitoring) Thermoplastic enclosure Sensor technology permits an offset of ± mm between actuator and interlock Intelligent

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

SensaGuard TM 18 mm Stainless Steel Barrel Installation Instructions

SensaGuard TM 18 mm Stainless Steel Barrel Installation Instructions TM 18 mm Stainless Steel Barrel Installation Instructions Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE PN-75056-181 ver 05 March 2012 2 TM 18 mm Stainless Steel Barrel Installation

More information

Safety door-handle system STS

Safety door-handle system STS Safety door-handle system STS Full body access ha Safety door-handle system STS EN 1037 Features The safety door-handle system is suitable for all types of safety guards. Safety switches and solenoid interlocks

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power SEFTEST 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with self-test function For self-contained emergency lighting SEV for output voltage

More information

DLKEK3HN INSTALLATION INSTRUCTIONS

DLKEK3HN INSTALLATION INSTRUCTIONS DLKEK3HN INDEX: INSTALLATION INSTRUCTIONS WIRING INSTRUCTIONS... PG 2-5 LED STATUS INDICATOR... PG 6 VALET/OVERRIDE BUTTON... PG 6 SHOCK SENSOR... PG 7 PROGRAMMABLE JUMPER-PINS... PG 7 PROGRAMMING REMOTE

More information

Senior Swing Control Box. Table of Contents

Senior Swing Control Box. Table of Contents *740100* 740100 2800 Overhead Consealed Series 9500 Surface Applied Series Senior Swing Control Box Installation Instructions important These instructions are presented in step-by-step sequence. It is

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output

More information

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept pg. 3 TS-6 & TS-16 Mini Sensing Edges Low profile with high sensitivity Immediate activation,

More information

GENSET CONTROL MODULE A121A / A241A

GENSET CONTROL MODULE A121A / A241A Technical Data Sheet GENSET CONTROL MODULE A121A / A241A Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 4-alarm light outputs with lamp-test provisions.

More information

224-EN WIRELESS CONTROLLER INSTALLATION & INTERFACE GUIDE. Guide No. 224-EN USING AS REPLACEMENT CONTROLLER

224-EN WIRELESS CONTROLLER INSTALLATION & INTERFACE GUIDE. Guide No. 224-EN USING AS REPLACEMENT CONTROLLER INSTALLATION & INTERFACE GUIDE USING AS REPLACEMENT CONTROLLER Confirm software version on existing controllers See Parameter 80 If Parameter 80 is 18 or lower change Parameter 54 to 1 Guide No. Contents

More information

Heavy-Duty Safety Interlock Switch with Guard Door Locking

Heavy-Duty Safety Interlock Switch with Guard Door Locking C R US Conforms to EN1088, EN60947--1, EN292, EN60204-1 UL and C-UL listed TL8018- Heavy-Duty Safety Interlock Switch with uard Door Locking High locking force of,00 N (1,236 lb.) locks guard door shut

More information

General Purpose Incremental Encoder

General Purpose Incremental Encoder Model Number Features Up to 5000 ppr Industrial standard housing Ø58 mm Servo or clamping flange 10 V... 30 V with short-circuit proof push-pull output Description Compatibility says it all for this incremental

More information

Flight Systems. Replacement for KASSEC DESCRIPTION

Flight Systems.   Replacement for KASSEC DESCRIPTION DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most

More information

4 relays DIN actuator

4 relays DIN actuator TECHICA SHEET relays DI actuator Description By means of internal relays, this device executes the controls received from the central unit or from the probe. It is needed to control loads such as - -coils,

More information

USERS GUIDE LO-21U LOCKOUT RELAY

USERS GUIDE LO-21U LOCKOUT RELAY USERS GUIDE LO-21U LOCKOUT RELAY PRODUCT DESCRIPTION The LO-21U (PN: 10LO21U) is a micro-processed lock out module designed to operate on swing door applications with BEA s Bodyguard or DK-12 overhead

More information

Close-Open (Short-Circuit) Time Results Interpretation

Close-Open (Short-Circuit) Time Results Interpretation Application Note Close-Open (Short-Circuit) Time Results Interpretation Close-Open (C-O, trip-free) cycles simulate closing on a short circuit. In the actual event, the breaker closes first, then the protection

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

Technical specification. POW12V20A-D1 Charger. LFP/LTO + BMS connector

Technical specification. POW12V20A-D1 Charger. LFP/LTO + BMS connector Technical specification POW12V20A-D1 Charger LFP/LTO + BMS connector 1. Input characteristics 1-1 Rated input voltage 230V Vac 1-2 Input voltage range 180V 264V Vac 1-3 AC input voltage frequency 47-63

More information

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22. PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22 News 08 PROTECT SRB s Safety relay modules with intrinsically safe monitoring

More information

INSTRUCTION INVERTER COMPACT FOR SLIDING GATES /R0 10/11/2017

INSTRUCTION INVERTER COMPACT FOR SLIDING GATES /R0 10/11/2017 INSTRUCTI INVERTER COMPACT FOR SLIDING GATES 6-1622616 /R0 10/11/2017 2 / 20 3 / 20 1. INTRO The control unit INVERTER COMPACT is integrated in the motor KALOS XL. It is a device suitable for operating

More information

INSTALLATION GUIDE. FCC ID NOTICE

INSTALLATION GUIDE.  FCC ID NOTICE REV.5 RS. ADVANCED REMOTE STARTER INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This

More information

3200NT Timer Service Manual

3200NT Timer Service Manual Service Manual Valve Serial Number Valve Position 1-LEAd 2-LAg 3-LAg 4-LAg IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specifications Sheet.....................................................................

More information

SHIVVERS ROTATION DETECTOR. fshiwersf ROTATION DETECTOR 676A-001A

SHIVVERS ROTATION DETECTOR. fshiwersf ROTATION DETECTOR 676A-001A SHIVVERS ROTATION DETECTOR 676A-1A INSTALLATION & OPERATING INSTRUCTIONS fshiwersf ROTATION DETECTOR 676A-1A INDICATOR LIGHT Solid Red = Rotation Is OK Slow Flash (1 sec. on; 1 sec. off)= Rotation Detector

More information

Installation and Maintenancee Manual

Installation and Maintenancee Manual Installation and Maintenancee Manual Commercial Boom Gate Operator Model: GDS BOOM 4 and 6 A.B.N. 62 059 806 405 Nov 2013 Section No: CONTENTS Page Number: 1 Safety Precautions 3 2 Specifications 4 3 Mechanical

More information

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift) First, Sign and Date Bln 2009-03-9 Updated, Sign and Date Bln 200-04-29 (0) User Manual TTT802 Gearshift Controller Firmware for R--N-2- TTT802 Gearshift Controller, Part # 2-620-9-RN-S (Standard), -P

More information

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start. Technical Data Sheet GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 5-alarm light outputs with lamp-test

More information

Tina 10A/B/C Adaptor unit

Tina 10A/B/C Adaptor unit Original instructions Tina 10A/B/C Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Controller Test Procedure

Controller Test Procedure Controller Test Procedure GALaxy ehydro Elevator Controller G.A.L. Manufacturing Corp. 50 East 153 rd Street Bronx, N.Y. 10451 Tel: (718) 292-9000 Ext. 202 Mobile: (845) 235-1074 E-mail: rickc@gal.com

More information

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA). PD 65493 GB1 20001-01 ThinkTop DeviceNetTM 11-25 VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA). Application The ThinkTop is designed to ensure optimum valve control

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

GUIDE 200.V2 VSD VERTICALLY CONTROL SYSTEM & INTERFACE GUIDE. 202 Standard Operation 202 Slave Mode 201 Sequence of Operations

GUIDE 200.V2 VSD VERTICALLY CONTROL SYSTEM & INTERFACE GUIDE. 202 Standard Operation 202 Slave Mode 201 Sequence of Operations THE PEELLE COMPANY FREIGHT DOORS I CAR GATES I CAR ENCLOSURES GUIDE 200.V2 CONTROL SYSTEM & INTERFACE GUIDE 202 Standard Operation 202 Slave Mode 201 Sequence of Operations VSD VERTICALLY SLIDING DOORS

More information

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE REV. ARS. WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This device may not cause

More information

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION Instruction Bulletin Bulletin No. 0006-39-03 May 997 Raleigh, NC, USA Enclosed ALTISTART 6 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION This bulletin is a supplement to

More information

CTi Automation - Phone: Fax: Web:

CTi Automation - Phone: Fax: Web: CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with I interface and automatic test function For self-contained emergency lighting

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod

More information

Programmable 8 Channel Injector Driver Module

Programmable 8 Channel Injector Driver Module Overview: Programmable 8 Channel Injector Driver Module 554-142 The 8 channel fuel injector driver module allows for an input signal from any ECU to be changed into a user selectable peak and hold current.

More information

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12 Safety Door Handle System TGY with SIDENT Safety Switch Ref. no. 43.20-01 07, -11, -12 1. Purpose Automated systems with dangerous machine functions require guards to ensure that the operating personnel

More information

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions UGB4-KLT with Sliding Handle Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions UGB2-KLT Application: The UGB-KLT Gate Box (incorporating an RFID interlock switch) is designed to fit

More information

Redundant Control System

Redundant Control System Redundant Control System Safety instrumented system applications up to SIL 3 Process reliability Process valve diagnostics COMPLETE FUNCTIONAL SAFETY WITH ENHANCED RELIABILITY The Redundant Control System

More information

CAUTION CM-SE CM-S21 CM-S41

CAUTION CM-SE CM-S21 CM-S41 CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE 4 NHP SAFETY REFERENCE GUIDE CONTENTS SAFETY TECHNOLOGY Risk Reduction Options Permanent Fixed Guard 4-02 Interlocked Guard: 4-03 Limit Switches 4-08 Presence Sensing Technology 4-09 Safety Laser Scanners

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F Starting System DS-102 Series 200 Elmatik AS P.O.Box 309 NO-3471, Slemmestad T - +47 31 28 37 83 F - +47 31 28 37 93 www.elmatik.no post@elmatik.no CONTENT 1. INTRODUCTION 3 2. TECHNICAL SPECIFICATIONS

More information

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series PRO 50 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output

More information

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE 5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE MODEL# 505 ( AMP @ VDC OR 4VDC) MODEL# 5500 ( AMP @ VDC OR AMPS @ 4VDC) MODEL# 5600- (0 AMPS @ VDC) MODEL# 5600-4 (5 AMPS @ 4VDC) IMPORTANT SAFETY INSTRUCTIONS

More information

4 Redundant Control System

4 Redundant Control System 4 Redundant Control System Introducing the all NEW RCS Configurator Safety Instrumented Systems Process Reliability Process Valve Diagnostics COMPLETE FUNCTIONAL SAFETY WITH ENHANCED RELIABILITY The Redundant

More information

SPECIAL DUST EXPLOSIVES ATMOSPHERES

SPECIAL DUST EXPLOSIVES ATMOSPHERES SPECIAL DUST EXPLOSIVES ATMOSPHERES Explosive atmospheres Main sectors of activity subject to a higher risk of explosion or fire Flour mills Wood and aluminium workshops A reference for installations in

More information

231.V1 GUIDE VSD. CONTROL SYSTEM & INTERFACE GUIDE C/W TDP (Total Door Protection) Dual Light Curtains

231.V1 GUIDE VSD. CONTROL SYSTEM & INTERFACE GUIDE C/W TDP (Total Door Protection) Dual Light Curtains I CAR GATES I CAR ENCLOSURES GUIDE FREIGHT DOORS INTERFACE GUIDE C/W TDP (Total Door Protection) Dual Light Curtains 202 Standard Operation 202 Slave Mode 201 Sequence of Operations VSD VERTICALLY SLIDING

More information

Hall Coded Non-contact Safety Switches. Model Number Structure

Hall Coded Non-contact Safety Switches. Model Number Structure Hall Coded Non-contact Safety Switches FS-TGR-N@C Hall coded non-contact switches monitor the status of guarding doors. Stainless steel housing for high hygiene demands in the food industry are available.

More information

MANUAL. MiniMax V / VK

MANUAL. MiniMax V / VK MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER MiniMax V / VK Revised 2014-10-07 Version 1.3.1 F21037901GB Declaration of Manufacturer The manufacturer s assurance of the agreement of the product with

More information

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition WWW.STELLAR.COM Button Function Condition 1 a. Arm and lock doors b. Car finder with sound c. Temporary stop alarm from sounding d. Remote lock doors 1 for 2 sec. Panic Anytime a. Alarm is disarmed b.

More information

Field Commander Lite Wiring Manual

Field Commander Lite Wiring Manual 2014-17 Field Commander Lite Wiring Manual (New Large Style Board board label Comm6 FC V4.1 or V4.2 only 1 relay ) Section 1 Pages 2-6 Irrigation Pivot wiring. Section 2 Page 6 Simple on/off monitor only

More information

FAST XIM. XIM Unit Installation

FAST XIM. XIM Unit Installation 1 INSTRUCTIONS XIM Thank you for choosing products; we are proud to be your manufacturer of choice. Please read this instruction sheet carefully before beginning installation, and also take a moment to

More information

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding P33T Series Redundant Safety Exhaust Valve Catalogue PDE675TCUK October

More information

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes Sorensen XG 1700 Series 1700 W 1700 Watt, 1U Programmable DC Power Supplies 6 600 V Industry Leading Power Density Up to 1700 Watts in 1U Standard Digital Interfaces USB&RS232/485 LXI Ethernet and Isolated

More information

FMC-1/2 Tina Muting unit

FMC-1/2 Tina Muting unit Original instructions FMC-1/2 Tina Muting unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version T5 T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD T5c EM SEFTE, 220 240 V SEFTEST version Product description Emergency lighting supply unit with self-test function For linear and compact fluorescent lamps ow-profile

More information

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version T T TC-DE TC-SE TC-TE TC-F TC- TC-DD Tc EM, 0 40 V PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent lamps

More information

EC DECLARATION OF CONFORMITY

EC DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY Manufacturer : Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 844 T control board, conforms to the essential safety requirements of the

More information

Contents. Part no.: MLC510R Safety light curtain receiver

Contents. Part no.: MLC510R Safety light curtain receiver Part no.: 68001315 MLC510R30-1500 Safety light curtain receiver Figure can vary Contents Technical data Suitable transmitters Dimensioned drawings Electrical connection Circuit diagrams Operation and display

More information

Solenoid interlock AZM 200 The non-contact interlock.

Solenoid interlock AZM 200 The non-contact interlock. Solenoid interlock AZM 200 The non-contact interlock. Solenoid interlock AZM 200 The non-contact Solenoid interlocks demand accurate alignment of actuator and device. This requirement is met on new machinery.

More information

SiCan Simple CAN Extension Charger to PacMon

SiCan Simple CAN Extension Charger to PacMon SiCan Simple CAN Extension Charger to PacMon Provides and extension charger to PacMon. Drives CAN TC (Elcon) type chargers. Interfaces with the CMon, SiMon, and UMon. Programmable high and low (balance)

More information

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing IDEM MPC Non-Contact Coded Magnetic MPC Series Plastic Housing MPC-114105 Coded magnetic actuation Compact yet robust fitting suitable for all small guard applications Hygenic screw cap covers ensure suitability

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

INSTRUCTION MANUAL H WELDER INTERLOCK

INSTRUCTION MANUAL H WELDER INTERLOCK INSTRUCTION MANUAL 700200H WELDER INTERLOCK MICROPROCESSOR BASED Welder Interlock Control Wiring Diagram 420721 NEMA 1 Cabinet ENTRON Controls, LLC. 1402 S. Batesville Road Greer, South Carolina 29650

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement

More information

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA MDC150-012301 12V, 30A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information