ACCESSIBILITY REVIEW

Size: px
Start display at page:

Download "ACCESSIBILITY REVIEW"

Transcription

1 Swinerton Builders CA Lic. N o Business Park Way, Suite 101 Sacramento, CA Tel: Fax: INTEGRITY LEADERSHIP PASSION EXCELLENCE ACCESSIBILITY REVIEW FOR Kimber Management, LLC 28 Liberty Ship Way Sausalito, CA Certified Access Specialist Survey By: Amy Casado, CASp 294

2 INTRODUCTION OVERVIEW: An on-site accessibility review of 28 Liberty Ship Way, Sausalito, CA, an existing Class B office building, was conducted during July and August of This review included facility and site accessibility including accessible routes of travel, parking, dos, and toilet facilities. Employee wk areas and alarm systems are excluded from this survey. A summary of findings and recommendations are contained herein. This survey has been conducted under the current code regulations listed below: 2010 ADA Standards f Accessible Design Title III 28 CFR Part 36 - Public Accommodations and Commercial Facilities** 2010 Califnia Building Code Title 24, Part 2, Chapter 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Publicly Funded Housing Califnia Building Code, Title 24, Part 2 Emergency Regulations effective July 1, **Element-by-Element Safe Harb The Standards include a general safe harb under which elements in covered facilities that were built altered in compliance with the 1991 Standards would not be required to be brought into compliance with the 2010 Standards until the elements were subject to a planned alteration. A similar safe harb applies to elements associated with the path of travel to an altered area. Refer to CFR Part , (d), (1), (i) Safe Harb f additional infmation. Findings and recommendations within this rept are based on interpretations and do not imply legal authity. As such, this rept is being provided without representations of warranties f err and/ omissions, either expressed implied. GENERAL INFORMATION: In public accommodations and commercial facilities, any renovation new construction that occurs after January 26, 1992, are subject to meet full code specifications of the Americans with Disabilities Act (ADA) Title III, 28 Code of Federal Regulations (CFR) Part 36; and Title 24, Part 2, of the Califnia Building Code (CBC); and are to be in full compliance with the most restrictive provisions of either the ADA the CBC. Although the CBC only requires improvements to access when an alteration to a facility takes place, public accommodations have an ongoing obligation to remove readily achievable barriers under the provisions of the ADA. Readily achievable barriers are defined as easily accomplished and able to be carried out without much difficulty expense. Determining if barrier removal is readily achievable is determined on a case by case judgment. Facts to consider are the nature and cost of the barrier and the financial resources of the entity and the parent company. Under the ADA, an entity must remove barriers as they are become readily achievable and is an on-going obligation until the building reaches full compliance. It is recommend that all barriers that are identified in this evaluation, and that are readily achievable, be removed as soon as possible with other barriers being removed as they become readily achievable. A transition plan should be developed to assist in planning the remediation of all barriers that are not currently readily achievable to remove. Periodic maintenance to ensure continued accessibility is essential in providing a safe and usable environment. Parking lot markings, signage, do opening Introduction - i

3 pressures, and maintaining clear flo space at dos and other elements and fixtures must be part of an ongoing maintenance schedule. Priities f barrier removal include the following: 1. An accessible entrance and path of travel 2. Access to goods and services 3. An accessible restroom f each sex 4. Accessible items such as drinking fountains, telephones, etc. 5. When possible, additional accessible elements such as parking, stage, and alarms Public accommodations ADA obligations f barrier removal can be found in Title 24, Part 2, Section 1134B of the Califnia Building Code; and the Department of Justice s ADA Title III regulations at 28 CFR part RESOURCES: Califnia Department of General Services Division of the State Architect, Access Compliance U.S. Department of Justice ADA Infmation ADA Standards f Accessible Design ADA Standards f Accessible Design ADA Update: A Primer f Small Business Tax Deductions and Credits f Barrier Removal Introduction - ii

4 Kimber Management, LLC 28 Liberty Ship Way Sausalito, Ca NOTICE TO PRIVATE PROPERTY OWNER/TENANT: YOU ARE ADVISED TO KEEP IN YOUR RECORDS ANY WRITTEN INSPECTION REPORT AND ANY OTHER DOCUMENTATION CONCERNING YOUR PROPERTY SITE THAT IS GIVEN TO YOU BY A CERTIFIED ACCESS SPECIALIST. IF YOU BECOME A DEFENDANT IN A LAWSUIT THAT INCLUDES A CLAIM CONCERNING A SITE INSPECTED BY A CERTIFIED ACCESS SPECIALIST, YOU MAY BE ENTITLED TO A STAY (TEMPORARY STOPPAGE) OF THE CLAIM AND AN EARLY EVALUATION CONFERENCE. IN ORDER TO REQUEST THE STAY AND EARLY EVALUATION CONFERENCE, YOU WILL NEED TO VERIFY THAT A CERTIFIED ACCESS SPECIALIST HAS INSPECTED THE SITE THAT IS THE SUBJECT OF THE CLAIM. YOU WILL ALSO BE REQUIRED TO PROVIDE THE COURT AND THE PLAINTIFF WITH THE COPY OF A WRITTEN INSPECTION REPORT BY THE CERTIFIED ACCESS SPECIALIST, AS SET FORTH IN CIVIL CODE SECTION THE APPLICATION FORM AND INFORMATION ON HOW TO REQUEST A STAYAND EARLY EVALUATION CONFERENCE MAY BE OBTAINED AT YOU ARE ENTITLED TO REQUEST, FROM A CERTIFIED ACCESS SPECIALIST WHO HAS CONDUCTED AN INSPECTION OF YOUR PROPERTY, A WRITTEN INSPECTION REPORT AND OTHER DOCUMENTATION AS SET FORTH IN CIVIL CODE SECTION YOU ARE ALSO ENTITLED TO REQUEST THE ISSUANCE OF A DISABILITY ACCESS INSPECTION CERTIFICATE, WHICH YOU MAY POST ON YOUR PROPERTY. This rept has been issued in compliance with Califnia Civil Code Section and does NOT comply with all applicable construction related accessibility standards. A CASp Determination Pending classification has been determined as defined in Califnia Civil Code Section (a) 5. A reasonable time frame f completing items noted in this rept and a determination of what barriers are Readily Achievable will be the responsibility of the property owner. Prepared by: Amy Casado 9/24/2013 Amy Casado, CASp #294 Date

5 TABLE OF CONTENTS TABLE OF CONTENTS General Facility and Survey Infmation Summary Sheets SECTION 1 Sheet A: Parking (PK) SECTION 2 Sheet B: Passenger Loading Zones (PZ) NOT APPLICABLE SECTION 3 Sheet C: Exteri Routes Of Travel (ER) SECTION 4 Sheet D: Entrances (EN) SECTION 5 Sheet E: Interi Routes of Travel (IP) SECTION 6 Sheet F: Rooms and s (RS) SECTION 7 Sheet G: Toilet Rooms (TR) SECTION 8 Sheet H: Assembly Use Areas (AA) NOT APPLICABLE SECTION 9 Sheet I: Alarms (AL) NOT APPLICABLE SECTION 10 Sheet J: Exhibits Survey Fms Fm 1: Parking Fm 2: Passenger Loading Zones NOT APPLICABLE Fm 3A: Exteri Routes of Travel, Public Rights-of-Way Fm 3B: Exteri Routes of Travel, On-Site Fm 4: Curb Ramps Fm 5: Drinking Fountains Fm 6: Telephones NOT APPLICABLE Fm 7: Ramps NOT APPLICABLE Fm 8: Stairs Fm 9: Platfm Lifts NOT APPLICABLE Fm 10: Building Entrances and Exits Fm 11: Dos and Gates Fm 12: Building Lobbies and Crids (Interi Accessible Route) Fm 13: Elevats Fm 14: Rooms and s Fm 15A: Large Assembly Areas NOT APPLICABLE Fm 15B: Small Assembly Areas NOT APPLICABLE Fm 16: Toilet Rooms Fm 17: Shower Facility Fm 18: Reserved Fm 19: Signage Fm 20: Alarms NOT SURVEYED Fm 21: Reserved Fm 22: Reserved Fm 23: Hazards

6 GENERAL FACILITY AND SURVEY INFORMATION Data Sheet Facility Name: Date: 28 Liberty Ship Way, Sausalito, CA September 16, 2013 a. Facility Name b. Facility Address (, Street) c. Facility Address (City, Zip) d. Contact Info e. Phone Fax f. Number of On-site Parking Stalls g. Square Footage h. of Sties and Size of Each i. Date of Construction (First Certificate of Occupancy) j. Date(s) and Type(s) of Previous Alteration(s) k. Circle Mark Type of Survey 28 Liberty Ship Way Sausalito, CA Bruce Huff ,000 2 Sties 2001 New Construction Renovation Lease Other (specify): GENERAL SURVEY l. Tenant Contact Info (Lease ) m. Suite (s) and Size of Each (SF) n. Name of Survey and Date of Survey o. Survey Contact Info p. Phone Fax Name: Amy Casado, CASp 294 P.O. Box 1929, Rocklin, CA Date: July/August acasado@pacfmance.com Additional Comments: See: EXHIBIT 1 28 LIBERTY SHIP WAY SITE PLAN EXHIBIT 2 28 LIBERTY SHIP WAY 1 ST FLOOR REFERENCE PLAN EXHIBIT 3 28 LIBERTY SHIP WAY 2 ND FLOOR REFERENCE PLAN

7 PARKING Summary Sheet A Facility Name: 28 Liberty Ship Way, Sausalito, CA Date: September 19, 2013 Parking: Where self-parking is provided f employees visits, each parking area/lot structure is required to have accessible parking spaces complying with the following table and with CBC Section 1129B. Total parking in area/lot structure Required minimum number of accessible spaces (including van) 1 to to to to to to to to to to percent of total 1001 and over 20 plus 1 f each 100 over 1000 At outpatient units and facilities 10 percent At facilities specializing in treatment f 20 percent persons with mobility impairments Note: s required by the table need not be provided in the particular area/lot structure. They may be provided at a different location if equivalent greater accessibility, in terms of distance from an accessible entrance, user cost and convenience, is ensured. In addition, one in every six (**one in every eight per 2010 CBC and 1991 Standards see Safe Harb provisions) accessible spaces, but not less than one, must be served by an access aisle 8 ft. wide minimum and must be designated "Van Accessible". SURVEY INCLUDES: ID Name/location of parking lots surveyed ( key number on site plan) Total parking in lot Total accessible* provided Total van accessible provided PK1 East West Minimum required accessible* Minimum required van accessible * Including van accessible spaces TOTAL Indicates the number of Survey Fms attached to Summary Sheet A in the field. Fm Fm Fm SF1 Parking 1 SF4 Curb Ramps SF5 Drinking Fountains SF6 Telephones SF7 Ramps SF11 Dos and Gates SF13 Elevats SF23 Hazards SECTION 1

8 PASSENGER LOADING ZONES Summary Sheet B Facility Name: 28 Liberty Ship Way, Sausalito, CA Date: September 19, 2013 Passenger Loading Zones Where passenger-loading zones are provided, at least one must be accessible and comply with CBC Section 1131B. Accessible passenger loading zones are to be identified by a sign bearing the International Symbol of Accessibility. Note: Valet parking facilities must provide an accessible passenger loading zone. SURVEY INCLUDES: ID Name/location of passenger loading zone surveyed ( key number on site plan) **NOT APPLICABLE** Indicates the number of Survey Fms attached to Summary Sheet B in the field. Fm Fm Fm SF2 Passenger Loading SF4 Curb Ramps SF23 Hazards SECTION 2

9 EXTERIOR ROUTES OF TRAVEL Summary Sheet C Facility Name: 28 Liberty Ship Way, Sausalito, CA Date: September 19, 2013 Exteri Routes of Travel An accessible route of travel must connect the following elements. Accessible routes must, to the maximum extent feasible, coincide with the routes f the general public. See Survey Fm 3A f accessible routes of travel to the public right-of-way, if adjacent to the property line of the site. See Survey Fm 3B f accessible routes of travel within the property line. At least one exteri accessible route of travel complying with CBC Section 1127B, must be provided between: and: Public transptation stops Accessible entrance* Accessible parking spaces Accessible entrance* Passenger loading zones Accessible entrance* Public streets and sidewalks Accessible entrance* Key facilities** Primary area *** * Accessible entrance means a primary entrance to the area subject to this survey. ** Key facilities means sanitary facilities, signs, drinking fountains, and public telephones serving the area subject to this survey. *** Primary area means the specific area subject to this survey. SURVEY INCLUDES: ID Name/location of routes of travel ( key number on site plan) Between: And: 3A 3B ER1 Marinship Way (Public Transptation) 28 Liberty Ship Way 3A ER2 28 Liberty Ship Way - Site 28 Liberty Ship Way Entrances 3B CR1 Curb Ramps Indicates the number of Survey Fms attached to Summary Sheet C in the field. Fm Fm Fm SF3 Exteri Routes (A+B) 2 SF4 Curb Ramps 1 SF5 Drinking Fountains SF6 Telephones SF7 Ramps SF8 Stairs SF9 Platfm Lifts SF13 Elevats SF19 Signage SF23 Hazards SECTION 3

10 ENTRANCES Summary Sheet D Facility Name: 28 Liberty Ship Way, Sausalito, CA Date: September 19, 2013 Primary Entrances CBC Section 1134B.2.1 requires at least one primary entrance serving the primary area to be accessible. Accessible routes to these entrances must, to the maximum extent feasible, coincide with the routes f the general public. In addition, if an entrance nmally serves one me of the functions listed below, that entrance must also be accessible. o Public transptation stops o Accessible parking spaces o Passenger loading zones o Public streets and sidewalks o Key facilities Note: In new construction all entrances and all ground flo exits must be fully accessible. SURVEY INCLUDES: ID EN1 28 Liberty Ship Way, Main Entry (South) EN2 28 Liberty Ship Way, Rear Exit (Nth) Name/location of entrances ( key number on site plan) **All other exteri dos surveyed with individual suites. Indicates the number of Survey Fms attached to Summary Sheet D in the field. Fm Fm Fm SF3 Exteri Routes (A+B) SF7 Ramps SF8 Stairs SF10 Entrances and Exits 2 SF11 Dos and Gates SF13 Elevats SF19 Signage SF23 Hazards SECTION 4

11 INTERIOR ROUTES OF TRAVEL Summary Sheet E Facility Name: 28 Liberty Ship Way, Sausalito, CA Date: September 19, 2013 Interi Routes of Travel An accessible route of travel must connect the accessible building facility entrances with all accessible spaces of the primary area and its key facilities. Accessible routes must, to the maximum extent feasible, coincide with the routes f the general public. If the primary area any of its key facilities is located on a level other than the ground flo level, an accessible elevat must provide access to that level. Elevat Exemption: Installation of an elevat is not required in an altered facility that is less than three sties has less than 3,000 square feet per sty, except with respect to any facility that houses a shopping center, a shopping mall, the professional office of a health care provider, a terminal, depot, other station used f specified public transptation an airpt passenger terminal. SURVEY INCLUDES: ID Name/location of routes of travel ( key number on site plan) Survey Fm IR1 Interi Route of Travel SF12 Lobbies & Crids, IR1 Drinking Fountain 1 st Drinking Fountain 2 nd Main Stairs Rear Stairs Elevat SF5 Drinking Fountains, IR1 1 st FL SF5 Drinking Fountains, IR1 2 nd FL SF8 Stairs, IR1 - Main SF8 Stairs, IR1 - Rear SF13 Elevat, IR1 First, Double Dos SF11 Dos and Gates, IR1 1 st FL SECTION 5

12 ROOMS AND SPACES Summary Sheet F Facility Name: 28 Liberty Ship Way, Sausalito, CA Date: September 19, 2013 Rooms and s All primary area rooms and spaces which are not specifically exempt by code which are not used solely as wk areas must be accessible. Areas that are used only by employees as wk areas must be designed and constructed so that individuals with disabilities can approach, enter, and exit the areas. Accessibility is not required to: (i) observation galleries used primarily f security purposes; (ii) nonoccupiable spaces accessed only by ladders, catwalks, crawl spaces, very narrow passageways, (iii) freight (non-passenger) elevats and frequented only by service personnel f repair purposes (e.g., elevat pits, elevat penthouses, piping equipment catwalks). Note: F lobbies, crids, assembly areas, and toilet rooms, see specific Summary Sheets. SURVEY INCLUDES: ID Room ID Wk area only? Indicate Yes No 1 st Survey Fm RS UB Yes SF11 Dos and Gates, RS RS Steve & Kate s Camp Yes SF11 Dos and Gates, RS2 Do A **Kitchen area located in Counter & Sink with no knee clearance. SF11 Dos and Gates, RS2 Do B SF11 Dos and Gates, RS2 Do C SF11 Dos and Gates, RS2 Do D RS Q Surgical (1 st ) Yes SF11 Dos and Gates, RS3 Do A SF11 Dos and Gates, RS3 Do B 2 nd RS Butler Shine Stern & Partners Yes SF14 Rooms and s, RS RS Q Surgical ( 2 nd ) Yes SF11 Dos and Gates, RS5 **Employee wk areas above surveyed f general access only. SECTION 6

13 TOILET ROOMS Summary Sheet G Facility Name: 28 Liberty Ship Way, Sausalito, CA Date: September 19, 2013 Toilet Rooms Each public and common use toilet room must be accessible and comply with CBC Section 1115B. Employee toilet rooms are considered to be "common use" toilet rooms. In existing buildings facilities when compliance with building standards would create an unreasonable hardship, an exception may be granted when equivalent facilitation is provided. When equivalent facilitation is used, the following applies: (1) all sanitary facilities are not required to comply with building standards when accessible sanitary facilities are provided within a reasonable distance of accessible areas, and (2) signage is provided at inaccessible sanitary facilities indicating the location of the nearest accessible sanitary facilities. SURVEY INCLUDES (Survey Fm 16 Toilet Rooms): ID Name/location/function of toilet room Survey Fm ( key number on site plan) TR1 Women s Restroom & Shower 1 st SF16 Toilet Rooms, Women s 1st SF17 Shower Facility, Women s 1st TR2 Men s Restroom & Shower 1 st SF16 Toilet Rooms, Men s 1st SF17 Shower Facility, Men s 1st TR3 Women s Restroom & Shower 2 nd SF16 Toilet Rooms, Women s 2nd SF17 Shower Facility, Women s 2nd TR4 Men s Restroom & Shower 2 nd SF16 Toilet Rooms, Men s 2nd SF17 Shower Facility, Men s 2nd SECTION 7

14 ASSEMBLY USE AREAS Summary Sheet H Facility Name: 28 Liberty Ship Way, Sausalito, CA Date: September 19, 2013 Assembly Use Areas An assembly area is defined as a room space accommodating a group of individuals f recreational, educational, political, social, amusement purposes, f the consumption of food and drink, including conference and meeting rooms, stadiums, grandstands, bleachers, athletic pavilions, gymnasiums and miscellaneous spt-related facilities, auditiums, assembly halls, theaters and related facilities, such as stages, enclosed and unenclosed platfms, and chestra pits. Assembly use areas must comply with the general accessibility requirements and CBC Section 1104B. See Survey Fm 15A f rooms with fixed seating and large assembly areas, and Fm 15B f smaller meeting and conference rooms up to 750 square feet in size. SURVEY INCLUDES: ID Name/location/function of assembly area ( key number on site plan) 15A 15B AA1 AA2 AA3 AA4 AA5 AA6 AA7 AA8 AA9 AA10 Room On flo **NOT APPLICABLE** Indicates the number of Survey Fms attached to Summary Sheet H in the field. Fm Fm Fm SF5 Drinking Fountains SF6 Telephones SF7 Ramps SF8 Stairs SF9 Platfm Lifts SF10 Entrances and Exits SF11 Dos and Gates SF12 Lobbies and Crids SF15A Large Assembly SF15B Small Assembly SF19 Signage SF20 Alarms SF23 Hazards SECTION 8

15 ALARMS Summary Sheet I Facility Name: 28 Liberty Ship Way, Sausalito, CA Date: September 19, 2013 Alarm Systems If fire, evacuation, emergency warning systems are required provided at a building facility, then they must include both audible alarms and visual alarms complying with CBC Sections , , , and 1114B.2.2. Emergency warning systems in medical care facilities, large assembly areas, and detention facilities may be modified to suit specific use and safety standards. SURVEY INCLUDES: ID AL1 Name of building facility (e.g., main building) Part of building facility (e.g., east wing) On flo Room AL2 AL3 **NOT APPLICABLE** Alarms not surveyed. Fire Alarm Systems to comply with NFPA 72. Indicates the number of Survey Fms attached to Summary Sheet I in the field. Fm Fm Fm SF20 Alarms SF23 Hazards SECTION 9

16 EXHIBITS Facility Name: 28 Liberty Ship Way, Sausalito, CA Summary Sheet J Date: September 19, 2013 ID Reference /Description 1 Exhibit 1 28 Liberty Ship Way Site Map 2 Exhibit 2 28 Liberty Ship Way 1 st Reference Plan 3 Exhibit 3 28 Liberty Ship Way 2 nd Reference Plan Indicates the number of Survey Fms attached to Summary Sheet J in the field. Fm Fm Fm SECTION 10

17 PARKING Survey Fm 1 /Room Name: 28 Liberty Ship Way, Parking : PK1 : : 1.1 Number - Where parking spaces are provided f self-parking Accessible by employees visits both, is the required Parking s number of accessible parking spaces provided? (See Minimum Summary Sheet A) (Note: All some of the accessible parking spaces may be in a different location if equivalent greater accessibility is ensured.) /// 1129B.1; 1129B.2; Table 11B Each Area/Lot Are the accessible parking spaces located in each specific area/lot? OR If the accessible parking spaces are in a different location, is equivalent greater accessibility provided in terms of distance from the accessible entrance, user cost and convenience? /// 1129B Van Accessible s Is one in every six accessible parking spaces (but not less than one) designated "van accessible? /// 1129B.3 item 2, 1129B.4 2 stalls total no van accessible stall. Located directly in front of entrance. 3 stalls required and no less than 1 must be van accessible. Add an accessible parking stall and access isle that meet the requirements of a van accessible stall. See notes in 1.1 **1 in 8 required by 1991 Standards and CBC See Safe Harb Provisions 1.4 Location - Are accessible parking spaces which serve a Serving particular building on the shtest accessible route of Accessible travel from adjacent parking to the building's Entrance accessible entrance? /// 1129B Lot Layout Are parking stalls arranged so that persons with disabilities are not compelled to wheel walk behind parked cars other than their own? /// 1129B.3 item Serving Multiple Accessible Entrances 1.7 Separate Parking Facility 1.8 Parking Width 1.9 Van Access Aisle If the building has multiple accessible entrances with adjacent parking, are the accessible parking spaces on the shtest accessible route of travel to the parking facility's accessible pedestrian entrance? /// 1129B.1 Where a parking facility does not serve a particular building, are the accessible parking spaces on the shtest accessible route of travel to the parking facility's accessible pedestrian entrance? /// 1129B.1 Are accessible parking spaces, including van spaces, at least 9 wide and 18 long with a demarcated access aisle? (two spaces may share a common aisle) /// 1129B.3 items 1 & 2 If the parking space is designated as "van accessible," is the adjacent access aisle at least 8 wide by 18 long and located on the passenger side of the vehicle space? /// 1129B.3 item 2 Accessible stalls located at Main Entrance. Van accessible parking stall is required. Provide van accessible parking space. Page 1 of 3

18 PARKING Survey Fm 1 /Room Name: 28 Liberty Ship Way, Parking : PK1 : : 1.10 Car Access Aisles Are all other access aisles at least 5 wide and 18 long? /// 1129B.3 item Level Surface Are the accessible parking spaces and access aisles level with no slope greater than 2% in all directions? (This means a curb ramp cannot project into the access aisle.) /// 1129B.3 items 3 & Surface Are access aisles stable, firm, and slip resistant? /// 1124B Access Aisle and Accessible Route Does each access aisle connect directly to an accessible route of travel? (Use Fm 3 - Exteri Routes of Travel) /// 1129B Parking Does each accessible parking space have a reflectized sign (at least 70 sq in) visible from each stall showing the ISA and shall include an additional sign, language, below the symbol of accessibility stating Minimum Fine $ /// 1129B Van Accessible Parking Do van accessible spaces have a sign stating "Van Accessible" below the ISA? /// 1129B Sign Height Are the signs 60 minimum above the finished flo ground surface measured to the bottom of sign; a minimum height of 80 from the bottom of the sign when located in a path of travel? /// 1129B Pavement Striping Is the loading and unloading access aisle marked by a bder painted blue? Within the blue bder, are hatched lines, a maximum of 36 on center, painted a col contrasting with the parking surface (preferably blue white)? /// 1129B.3 items 1 & Pavement Sign Is there a 36 square ISA painted on the pavement at the rear of the stall? /// 1129B Lettering Are the wds NO PARKING provided in each access aisle, painted in white, 12 high letters? /// 1129B.3 items 1 & 2 Slopes in left hand stall ok. Slopes in access aisle between 2.2% and 2.3%. Slopes in right hand stall at 2.6 near wheel stop. Slopes in access aisle between 2.2% and 2.3%. Slopes along accessible path of travel exceed 2%. (2.5% cross slope approaching the Main Entrance) are mounted lower than the 60 minimum to the bottom of the sign. Level accessible parking and access isle so slopes do not exceed 2% in any direction. Level accessible path of travel so cross slopes do not exceed 2%. Van accessible stall required. Raise accessible parking signs so that the bottom of the sign is a minimum of 60 above the ground surface. Page 2 of 3

19 PARKING Survey Fm 1 /Room Name: 28 Liberty Ship Way, Parking : PK1 : : 1.20 Tow-away Sign Is there a tow-away sign posted in a conspicuous place at each entrance to off street parking lot, immediately adjacent to and visible from each accessible stall? /// 1129B Van Accessible s - Vertical Clearance 1.22 Van Accessible s - Vertical Clearance Do van accessible spaces have a vertical clearance of at least 8-2? /// 1130B Does one vehicular access route to and from van accessible spaces have a vertical clearance of at least 8-2? (Van accessible spaces may be grouped on one level of a parking structure.) /// 1130B Sign provided at Nth West parking lot entrance. A Tow-Away sign will need to be provided at the Nth East entrance that also serves 30 Liberty Ship Way. See 30 Liberty Ship Way rept f crection item Other NOTES: PK1-002 Page 3 of 3

20 EXTERIOR ROUTES OF TRAVEL (Public Rights-of-Way Only) Survey Fm 3A /Room Name: 28 Liberty Ship Way : ER1 : : 3.1A Accessible Route of Travel in the Public Right of Way Is there an accessible route of travel linking an accessible site entrance with the following, if provided and if adjacent to the property line of the site: public transptation stops, passenger loading zones, accessible parking, and public sidewalks? /// 1114B A Width Is the accessible route of travel at least 48 wide except at doways gates? /// 1133B A Surface Are accessible route surfaces stable, firm and slipresistant? /// 1124B.1 3.4A Head Room Is there at least 80 clear head room within the pedestrian circulation area, including the accessible route of travel? 307 /// 1133B A Protruding Objects 3.6A Protruding Objects If wall-mounted objects have leading edges between 27 and 80 from the flo, do they project less than 4 into the circulation path (objects with leading edges at below 27 may project any amount)? If wall-mounted objects project into the circulation path, is the required clear width of the accessible route of travel maintained? /// 1133B Do free-standing objects mounted on posts with leading edges between 27 and 80 high (such as a sign telephone) overhang 12 less above the ground finish flo? If free-standing objects mounted on posts project into the circulation path, is the required clear width of the accessible route of travel maintained? /// 1133B A Cross Slope Is the cross slope of the accessible route of travel no greater than 1:50 (2 percent)? /// 1133B A Running Slope 3.9A Changes in Level Is the slope of the accessible route of travel no greater than 1:20 (5 percent), unless it complies with the requirements of a ramp it does not exceed the grade of the adjacent roadway? /// 1133B.7.3 When walkway levels change abruptly, is the vertical distance between them less than 1/4 inch? OR Are changes in level between 1/4 inch and 1/2 inch beveled with a slope no greater than 1:2? /// 1124B.2 Or See comments below in Notes section. Cross slopes exceed 2% (min) throughout all of the paths of travel. Consider landscaping/trees at paths from walking trail to south parking lot. With the exception of curb ramps. See SF4 Curb Ramps. x x Page 1 of 2

21 EXTERIOR ROUTES OF TRAVEL (Public Rights-of-Way Only) Survey Fm 3A /Room Name: 28 Liberty Ship Way : ER1 : : 3.10A Changes in Level 3.11A Grates and Drains 3.12A Hazardous Vehicular Areas - Detectable Warnings Are all curb ramps and ramps compliant? (See Fm 4 - Curb Ramps Fm 7 - Ramps) Is the smaller dimension of a grate opening in the accessible route of travel no me than 1/2 inch, and are long dimensions of rectangular gaps placed perpendicular to the usual direction of travel? /// 1124B.4 If an accessible route of travel crosses adjoins the vehicular way and the walking surface is not separated by curbs, railings, other elements between the pedestrian areas and vehicular areas, is the boundary between the areas defined by a continuous detectable warning at least 36 wide complying with 1133B.8.5? Or Curb ramps at the sidewalk on the Nth Side of Liberty Ship Way, running East and West, at Buildings 28 and 30 drive way entrances, require detectable warning surfaces. Truncated domes do not separate pedestrian areas from vehicular areas typical through entire site. Install truncated domes at curb ramps as required per CBC 1127B.5 Install continuous truncated domes, 36 wide, where a pedestrian path conjoins crosses a vehicular way. 3.13A Other NOTES: South Side A bus stop is located at Bridgeway and Mariship Way. There is a sidewalk on the Nth side of Marinship Way that intersects with Liberty Ship Way; however, there is no sidewalk along Liberty Ship Way running in the East/West direction. A walking path diverts off Marinship Way which runs parallel along the South side of 10/20 Liberty Ship Way, 28 Liberty Ship Way and 30 Liberty Ship Way. Individual paths provide access from the walking path to the south parking lots of each building. Refer to Site Map Exhibit 1. Access from the walking path to the south side of 28 Liberty Ship Way does not have the 48 required clearance as there is a bollard installed in the center of the path. There is no defined path of travel from the walking path to the front entrance of the building. **An accessibility survey was not conducted on the sidewalk along Marinship Way the walking path running along the south side of 10/20, Liberty Ship Way. Nth Side A 60 sidewalk runs along Liberty Ship Way in the East and West direction along the Nth property line of 28 Liberty Ship Way and 30 Liberty Ship Way. A 4 sidewalk T s off the street sidewalk on each side of 28 Liberty Ship way providing access to the building. These sidewalks provide access to the building on the nth side which then connect to a path of travel around the building to the Main Entry on the South side (See Survey Fm 3B). (Note: The sidewalk from the stair exit on the Nth side of Liberty ship way is non-compliant in both width and running slopes. See ER2, SF3B Exteri Routes of Travel (On-Site Only). Exception References: CBC 1127B Exteri Routes of Travel, Exception 2: In existing buildings, this section shall not apply in those conditions where, due to legal physical constraints, the site of the project would not allow compliance with these regulations equivalent facilitation without creating an unreasonable hardship ADA Standards Site Arrival Points, Exception 2: An accessible route shall not be required between site arrival points and the building facility entrance if the only means of access between them is a vehicular way not providing pedestrian access. Page 2 of 2

22 EXTERIOR ROUTES OF TRAVEL (On-Site Only) Survey Fm 3B /Room Name: 28 Liberty Ship Way : ER2 : : 3.1B On-site Accessible Route of Travel 3.2B Route f General Public 3.3B Facilities Connected Is there an accessible route of travel within the property line of the site linking an accessible building entrance with site arrival points serving the following, if provided: public transptation stops, passenger loading zones, accessible parking, and public sidewalks? /// 1114B.1.2, 1127B.1 Does the accessible route of travel, to the maximum extent feasible, coincide with the route f the general public? /// 1114B.1.2 Are there accessible routes of travel connecting all accessible buildings, facilities, elements and spaces on the same site with one another? /// 1114B.1.2, 1127B.1 3.4B Width Is the accessible route of travel at least 48 wide except at doways gates? /// 1133B B Passing s If the accessible route of travel is less than 60 wide, are there passing spaces at least 60 by 60 intersecting walks provided, allowing passing at reasonable intervals not exceeding 200? /// 1133B B Head Room Is there at least 80 clear head room within the pedestrian circulation area, including the accessible route of travel? 307 /// 1133B B Protruding Objects If wall-mounted objects have leading edges between 27 and 80 from the flo, do they project less than 4 into the circulation path (objects with leading edges at below 27 may project any amount)? If wall-mounted objects project into the circulation path, is the required clear width of the accessible route of travel maintained? /// 1133B Sidewalks are Designate an located on the accessible path Nth side of the of travel from the building, but a path walking path to of travel needs to the front entrance be defined from the walking path to the main entrance on the South side. See above. Sidewalks from Liberty Ship Way on the Nth side are 48. Sidewalk from Stair Exit is 36 wide and should be 48. The path of travel from the walking path does not have 48 as there is a bollard installed in the middle of the path. x x Page 1 of 3

23 EXTERIOR ROUTES OF TRAVEL (On-Site Only) Survey Fm 3B /Room Name: 28 Liberty Ship Way : ER2 : : 3.8B Protruding Objects Do free-standing objects mounted on posts with leading edges between 27 and 80 high (such as a sign telephone) overhang 12 less above the ground finish flo? If free-standing objects mounted on posts project into the circulation path, is the required clear width of the accessible route of travel maintained? /// 1133B B Cross Slope Is the cross slope of the accessible route of travel no greater than 1:50 (2 percent)? /// 1133B B Running Slope 3.11B Running Slope 3.12B Changes in Level 3.13B Changes in Level Is the slope of the accessible route of travel no greater than 1:20 (5 percent), unless it complies with item 12 below? /// 1133B.7.3 Where the slope is greater than 1:20 (5 percent), does it comply with the requirements f ramps? (See Fm 7 - Ramps) 405 /// 1133B.5 When walkway levels change, is the vertical distance between them less than 1/4 inch? OR Are changes in level between 1/4 inch and 1/2 inch beveled with a slope no greater than 1:2? /// 1124B.2 Are curb ramps, ramps, elevats compliant? (See Fm 4 - Curb Ramps) 3.14B Surface Are accessible route surfaces stable, firm and slipresistant? /// 1124B B Grates Is the smaller dimension of a grate opening no me than 1/2 inch, and are long dimensions of rectangular gaps placed perpendicular to the usual direction of travel? /// 1124B B Abrupt Changes in Level >4 3.17B Abrupt Changes in Level >30 Is the site free of abrupt changes in level adjacent to pedestrian areas exceeding 4 vertical except (1) between a walk sidewalk and an adjacent street driveway, (2) where a 6 high warning curb 42 high guard is provided to warn of a potential drop off? /// 1133B.8.1 Is the site free of abrupt changes in level adjacent to pedestrian areas exceeding 30 vertical except were a 42 high guard is provided to prevent persons from falling off the open edge? /// See f exceptions. Cross slopes exceed 2% (min) throughout all paths of travel. The running slope of the walk from the do landing to the street sidewalk exceeds 8.6% which is greater than the max allowable f ramps. Curb ramps require detectable warnings. This section of walk will need to be reconfigured f width and slopes. Page 2 of 3

24 EXTERIOR ROUTES OF TRAVEL (On-Site Only) Survey Fm 3B /Room Name: 28 Liberty Ship Way : ER2 : : 3.18B Entrance 3.19B Directions to Accessible Entrance 3.20B Hazardous Vehicular Areas - Detectable Warnings Are signs at primary public entrances and at every maj junction where the accessible route of travel diverges from the regular circulation path compliant? /// 1117B , 1127B.3 When not all entrances are accessible, is there directional signage indicating the accessible route to an accessible entrance? /// 1117B If a walk crosses adjoins the vehicular way and the walking surface is not separated by curbs, railings, other elements between the pedestrian areas and vehicular areas, is the boundary between the areas defined by a continuous detectable warning at least 36 wide complying with1133b.8.5? Install continuous truncated domes, 36 wide, where a pedestrian path conjoins crosses a vehicular way. 3.21B Other NOTES: The walk surrounding 28 Liberty Ship Way is flush with the parking area, a curb detectable warning surfaces will need to be installed around the perimeter of the building to separate the pedestrian area from the vehicular area. See 3.20B above. Page 3 of 3

25 CURB RAMPS Survey Fm 4 /Room Name: 28 Liberty Ship Way, Nth Sidewalk : CR1 : : 4.1 Curb Ramp Location Is there a curb ramp wherever an accessible route crosses a curb? 406 /// 1127B.5 item Slope Is the slope of the curb ramp the least possible slope but in no case me than 8.3%? /// 1127B.5 item Transition Is the transition from the curb ramp to the road gutter flush and free of abrupt changes? /// 1127B.5 item Counter Slope Are the running slopes of the road, gutter accessible route adjoining the ramp no greater than 5%? /// 1127B.5 item Width Is the width of the curb ramp, not including the flared sides, at least 48? /// 1127B.5 item Surface Is the surface of the curb ramp stable, firm and slipresistant? /// 1127B.5 item Grooved Bder 4.8 Side Flare Slope 4.9 Side Flare Slope 4.10 Built-up Curb Ramps 4.11 Detectable Warning 4.12 Detectable Warning 4.13 Parked Vehicles Is there a 12 grooved bder along the top and sides of the ramp at the level of the surface sidewalk? ///1127B.5 item 6 Do the flared sides have a slope of 10% less (measured along the curb)? /// 1127B.5 item 3 Where the landing at the top of the ramp is less than 48 deep and wheelchair users must use the side flares f access, do the flared sides have a slope of 8.3% less (measured along the curb)? /// 1127B.5 item 4 Are built-up curb ramps located so that they do not project into vehicular traffic lanes parking access aisles? /// 1127B.5 item 1, 1129B.3 items 3 & 4 Does the curb ramp have detectable warning? /// 1127B.5 item 7 Does the detectable warning consist of raised truncated domes, which contrast visually with adjoining surfaces (light-on-dark dark-on-light), and is the material used to provide contrast an integral part of the walking surface? /// 1127B.5 item 7 Are curb ramps located protected so that they will not be obstructed by parked vehicles? ///1127B.5 item 8 Curb ramp on west side of driveway to 20 Liberty Ship Way has a slope of 10.6% and the curb ramp on the east side of the driveway has a slope of 10.5% No truncated domes. Reconfigure ramp by extending the run so slopes do not exceed 8.3%. Install detectable warnings as required below. Install as required. Page 1 of 2

26 CURB RAMPS Survey Fm 4 /Room Name: 28 Liberty Ship Way, Nth Sidewalk : CR1 : : 4.14 Curb Ramps at Crosswalks Where pedestrian crossings are identified by lines, are curb ramps at wholly contained within the crosswalk lines, except f the flared sides? /// 1127B.5 items 1 & Bottom Landing Is the bottom 48 x 48 landing completely contained within the crosswalk lines? /// 1127B.5 item Straight Curb If the diagonal curb ramp has flared sides, is there at least a 24 segment of straight curb located on each side of the curb ramp within the crosswalk lines? /// 1127B.5 item Island Where the accessible route of travel crosses a median island, is the island curb cut through at street level? OR Are there curb ramps on both sides and a level area at least 48 long between them? /// 4.18 Other NOTES: Page 2 of 2

27 BUILDING ENTRANCES AND EXITS Survey Fm 10 /Room Name: 28 Liberty Ship Way, Main Entrance : EN1 : : 10.1 Entrances Serving Site Arrival Points Is there at least one accessible entrance connected by an accessible route to each type of existing site arrival point (i.e.: public transptation stops, accessible parking and passenger loading zones, and public streets sidewalks)? (See Fm 3 - Exteri Routes of Travel) /// 1114B Entrance Sign Are all accessible entrances identified by an ISA? /// 1117B Directional Sign If an entrance is not accessible, are there directional signs indicating the location of the nearest accessible entrance? /// 1117B Dos At each accessible entrance to a building facility, is there at least one accessible do complying with the requirements below? /// 1133B , 1133B Clear Do Opening 10.6 Do Maneuvering 10.7 Do Maneuvering When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? /// 1133B , 1133B.2.2 If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B.2.6 Refer to Survey Fm 3B ER2. Add the International Symbol of Accessibility at accessible entrances provide directional signage to nearest accessible entrance. Page 1 of 2

28 BUILDING ENTRANCES AND EXITS Survey Fm 10 /Room Name: 28 Liberty Ship Way, Main Entrance : EN1 : : 10.9 Do Threshold Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Do Hardware Are all handles, locks, and latches other operative devices operable with one hand? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Tactile Exit Tactile Exit Tactile Exit Directional Exit At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? ; /// item 3 & 4 Is there directional signage posted at all inaccessible exits indicating the direction to the nearest accessible exit? The sign must be located so that the route does not have to be retraced, and must comply with the requirements f visual signs /// >20 lbs per leaf. Adjust closer. Add signage per referenced code Other NOTES: Page 2 of 2

29 BUILDING ENTRANCES AND EXITS Survey Fm 10 /Room Name: 28 Liberty Ship Way, Rear Exit : EN2 : : 10.1 Entrances Serving Site Arrival Points Is there at least one accessible entrance connected by an accessible route to each type of existing site arrival point (i.e.: public transptation stops, accessible parking and passenger loading zones, and public streets sidewalks)? (See Fm 3 - Exteri Routes of Travel) /// 1114B Entrance Sign Are all accessible entrances identified by an ISA? /// 1117B Directional Sign If an entrance is not accessible, are there directional signs indicating the location of the nearest accessible entrance? /// 1117B Dos At each accessible entrance to a building facility, is there at least one accessible do complying with the requirements below? /// 1133B , 1133B Clear Do Opening 10.6 Do Maneuvering 10.7 Do Maneuvering When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? /// 1133B , 1133B.2.2 If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Do Threshold Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Do Hardware Are all handles, locks, and latches other operative devices operable with one hand? /// 1133B Refer to Survey Fm 3B ER2. Exit Do Slopes at exteri do landing range from 2.4% to 3.2%. Page 1 of 2

30 BUILDING ENTRANCES AND EXITS Survey Fm 10 /Room Name: 28 Liberty Ship Way, Rear Exit : EN2 : : Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Tactile Exit Tactile Exit Tactile Exit Directional Exit At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? ; /// item 3 & 4 Is there directional signage posted at all inaccessible exits indicating the direction to the nearest accessible exit? The sign must be located so that the route does not have to be retraced, and must comply with the requirements f visual signs /// >18 lbs Adjust closer. Add signage per referenced code. Add signage at 2 nd flo do. Add signage at do between stairwell exit and Suite Other NOTES: Page 2 of 2

31 DRINING FOUNTAINS Survey Fm 5 /Room 28 Liberty Ship Way Name: Drinking Fountain 1 st IR1 : DF - 1 : 1st : 5.1 Drinking Fountains 5.2 Drinking Fountains 5.3 Accessible Route Where there is only one drinking fountain area on a flo, is there one drinking fountain accessible to wheelchair users and one accessible to persons who have difficulty bending stooping (e.g. hi-lo drinking fountain)? /// 1117B.1 item 1 Where there is me than one drinking fountain on a flo, are 50% wheelchair accessible? /// 1117B.1 item 1 Is the accessible drinking fountain on an accessible route? /// 1117B.1 item Depth Is the drinking fountain a minimum of 18 inches and a maximum of 19 inches in depth? /// 1117B.1 item Knee Is the knee clearance between the bottom of the apron and the flo at least 27 high, 30 wide, and 8 deep, the depth being taken from the front edge of the fountain back towards the wall post? /// 1117B.1 item Toe Is the toe clearance at least 9 high and 17 deep from the front edge of the fountain? /// 1117B.1 item Clear 5.8 Protruding Objects Is there a clear flo space at least 30 by 48 providing a fward approach (a side approach is not acceptable)? /// 1117B.1 item 2 If a wall-mounted drinking fountain has a leading edge between 27 and 80 from the flo, does it project less than 4 inches into the circulation path? /// 1117B.1 item Spout Height Is the bubbler outlet no higher than 36 above the flo and is the water flow at least 4 high to allow the insertion of a cup under the flow of water? 602.4, /// 1117B.1 item Location Is the bubbler outlet located within 5 of the front of the unit, with a water flow trajecty parallel nearly parallel to the front edge? /// 1117B.1 item 4, Controls - Location Are the controls front-mounted on the side located within 6 of the front edge? /// 1117B.1 item Operation Are the controls operable with one hand, and without tight grasping, pinching, twisting of the wrist, and is the fce to operate the controls no greater than 5 lbs? /// 1117B.6 item 4 Comments 27-1/2 35-1/ Other NOTES: Page 1 of 1

32 DRINING FOUNTAINS Survey Fm 5 /Room 28 Liberty Ship Way Name: Drinking Fountain 2nd IR1 : DF - 2 : 2nd : 5.1 Drinking Fountains 5.2 Drinking Fountains 5.3 Accessible Route Where there is only one drinking fountain area on a flo, is there one drinking fountain accessible to wheelchair users and one accessible to persons who have difficulty bending stooping (e.g. hi-lo drinking fountain)? /// 1117B.1 item 1 Where there is me than one drinking fountain on a flo, are 50% wheelchair accessible? /// 1117B.1 item 1 Is the accessible drinking fountain on an accessible route? /// 1117B.1 item Depth Is the drinking fountain a minimum of 18 inches and a maximum of 19 inches in depth? /// 1117B.1 item Knee Is the knee clearance between the bottom of the apron and the flo at least 27 high, 30 wide, and 8 deep, the depth being taken from the front edge of the fountain back towards the wall post? /// 1117B.1 item Toe Is the toe clearance at least 9 high and 17 deep from the front edge of the fountain? /// 1117B.1 item Clear 5.8 Protruding Objects Is there a clear flo space at least 30 by 48 providing a fward approach (a side approach is not acceptable)? /// 1117B.1 item 2 If a wall-mounted drinking fountain has a leading edge between 27 and 80 from the flo, does it project less than 4 inches into the circulation path? /// 1117B.1 item Spout Height Is the bubbler outlet no higher than 36 above the flo and is the water flow at least 4 high to allow the insertion of a cup under the flow of water? 602.4, /// 1117B.1 item Location Is the bubbler outlet located within 5 of the front of the unit, with a water flow trajecty parallel nearly parallel to the front edge? /// 1117B.1 item 4, Controls - Location Are the controls front-mounted on the side located within 6 of the front edge? /// 1117B.1 item Operation Are the controls operable with one hand, and without tight grasping, pinching, twisting of the wrist, and is the fce to operate the controls no greater than 5 lbs? /// 1117B.6 item 4 Comments 26-7/8 34-1/ Other NOTES: Page 1 of 1

33 STAIRS Survey Fm 8 /Room 28 Liberty Ship Way Name: Main Stairs IR1 : Main : : 8.1 Stairs Do public and common use interi and exteri stairs comply with the accessibility requirements below? 504 /// 1114B.1.1, 1133B Risers/Treads Are the risers closed? /// 1133B Risers/Treads Are the treads unifm and at least 11 wide measured from riser to riser and are the risers all unifm and between 4 and 7 in height? /// , 1133B.4.5.1, 1133B Col Strip Interi Stairs 8.5 Col Strip Exteri Stairs Is there a solid contrasting col stripe 2 wide parallel to and not me than 1 away from the nosing on the upper approach and the lower tread of the stairway? /// 1133B.4.4 Is there a solid contrasting col stripe 2 wide parallel to and not me than 1 away from the nosing on the upper approach and all treads of the stairway? /// 1133B Nosings Do stair nosings project no me than 1-1/4 past the face of the riser below? Is the transition from the nosing to the riser free of abrupt edges? (The 2007 CBC requires that stair nosings project no me than 1-1/4. The 2001, 1998 & 1995 CBC required that stair nosings project no me than 1-1/2. There is no requirement to retroactively alter existing nosing projections of 1-1/2 when constructed in compliance with the building code in effect at the time of iginal construction.) /// , 1133B Continuous Handrails Are there continuous handrails along both sides? 504.6, /// 1133B Handrails On dogleg switchback stairs, is the inside handrail continuous at landings? /// 1133B Exception Handrail Extensions 8.10 Diameter and Clearance Do the handrails extend a min. of 12 beyond the top nosing and 12 plus the tread width, beyond the bottom nosing, and are the tops of handrails between 34 and 38 above the stair nosings? /// 1133B.4.2.1, 1133B Is the diameter of the handrail between 1-1/4 and 1-1/2 in cross-sectional nominal dimension equivalent, and is the clear space between handrails and walls exactly 1-1/2? /// 1133B.4.2.5, 1133B Stairway Width Is the width of the stairway a minimum of 44? Are stairways serving an area of rescue assistance at least 48 wide between handrails? /// , Hazards Are handrail edges free of sharp abrasive elements and do they have edges with a min. radius of 1/8? /// 1133B /4 Riser 12 Tread 5/ / /2 clear between handrails. Page 1 of 2

34 STAIRS Survey Fm 8 /Room 28 Liberty Ship Way Name: Main Stairs IR1 : Main 8.13 Tactile Designation Are tactile flo designation signs located at each flo level landing in all enclosed stairways in buildings two me sties in height to identify the flo level; and at the exit discharge level, does the sign include a raised five pointed star? /// 1133B.4.3 At each exit do that leads directly to a grade-level exteri exit by means of a stairway identified by a tactile exit sign that states EXIT STAIR DOWN EXIT STAIR UP, as appropriate? /// Tactile Exit Signage 8.15 Other : : NOTES: Page 2 of 2

35 STAIRS Survey Fm 8 /Room 28 Liberty Ship Way Name: Rear Stairs IR1 : Rear : : 8.1 Stairs Do public and common use interi and exteri stairs comply with the accessibility requirements below? 504 /// 1114B.1.1, 1133B Risers/Treads Are the risers closed? /// 1133B Risers/Treads Are the treads unifm and at least 11 wide measured from riser to riser and are the risers all unifm and between 4 and 7 in height? /// , 1133B.4.5.1, 1133B Col Strip Interi Stairs 8.5 Col Strip Exteri Stairs Is there a solid contrasting col stripe 2 wide parallel to and not me than 1 away from the nosing on the upper approach and the lower tread of the stairway? /// 1133B.4.4 Is there a solid contrasting col stripe 2 wide parallel to and not me than 1 away from the nosing on the upper approach and all treads of the stairway? /// 1133B Nosings Do stair nosings project no me than 1-1/4 past the face of the riser below? Is the transition from the nosing to the riser free of abrupt edges? (The 2007 CBC requires that stair nosings project no me than 1-1/4. The 2001, 1998 & 1995 CBC required that stair nosings project no me than 1-1/2. There is no requirement to retroactively alter existing nosing projections of 1-1/2 when constructed in compliance with the building code in effect at the time of iginal construction.) /// , 1133B Continuous Handrails Are there continuous handrails along both sides? 504.6, /// 1133B Handrails On dogleg switchback stairs, is the inside handrail continuous at landings? /// 1133B Exception Handrail Extensions 8.10 Diameter and Clearance Do the handrails extend a min. of 12 beyond the top nosing and 12 plus the tread width, beyond the bottom nosing, and are the tops of handrails between 34 and 38 above the stair nosings? /// 1133B.4.2.1, 1133B Is the diameter of the handrail between 1-1/4 and 1-1/2 in cross-sectional nominal dimension equivalent, and is the clear space between handrails and walls exactly 1-1/2? /// 1133B.4.2.5, 1133B Stairway Width Is the width of the stairway a minimum of 44? Are stairways serving an area of rescue assistance at least 48 wide between handrails? /// , Hazards Are handrail edges free of sharp abrasive elements and do they have edges with a min. radius of 1/8? /// 1133B Riser 11-1/2 Tread See signage below. 36-1/2 1-1/2 44 Page 1 of 2

36 STAIRS Survey Fm 8 /Room 28 Liberty Ship Way Name: Rear Stairs IR1 : Rear : : 8.13 Tactile Designation 8.14 Tactile Exit Signage Are tactile flo designation signs located at each flo level landing in all enclosed stairways in buildings two me sties in height to identify the flo level; and at the exit discharge level, does the sign include a raised five pointed star? /// 1133B.4.3 At each exit do that leads directly to a grade-level exteri exit by means of a stairway identified by a tactile exit sign that states EXIT STAIR DOWN EXIT STAIR UP, as appropriate? /// Provide signage. Provide required signage Other NOTES: Page 2 of 2

37 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: 1 st Double Dos : IR1 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? , /// 1133B.2.3.3; 1133B Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? /// 1133B , 1133B.2.2, 1133B Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? /// 1133B Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? /// 1133B Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Refer to Survey Fm 12 Building Lobbies and Crids: IR1. Vestibule between 1 st double dos and do to Suite Page 1 of 3

38 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: 1 st Double Dos : IR1 : 1 : Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) /// 1133B Hardware Is any operating hardware mounted between 30 and 44 above the flo? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? /// 1133B Room/ Identification Tactile Exit Tactile Exit Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 >20 lbs Adjust closer. Install EXIT ROUTE sign per requirements below. Page 2 of 3

39 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: 1 st Double Dos : IR1 : 1 : Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, Other NOTES: Page 3 of 3

40 BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 28 Liberty Ship Way Main Crids : IR1 : 1 st & 2nd : 12.1 Accessible Route 12.2 Width - General Is there an accessible route of travel connecting accessible entrances with all accessible elements and spaces within the building? /// 1114B.1.2 Is the accessible route of travel, except at doways, at least 44 wide where the occupancy load is 10, at least 36 where the occupancy load is <10? /// 1133B U-Turn Where the accessible route of travel makes a U-turn around an obstacle which is less than 48 wide, is the accessible route at least 42 wide on the approaches and 48 wide in the turn? /// Fig 11B-5E 12.4 Surface Are the flo surfaces on the accessible route of travel stable, firm, and slip-resistant? /// 1124B Clear Do Opening 12.6 Do Maneuvering 12.7 Do Hardware 12.8 Do Operating Efft 12.9 Revolving Do When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? ( the N/A box if dos are being documented by another ption of your survey.) /// 1133B , 1133B.2.2 If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26A, B, C Are all handles, locks, and latches other operative devices operable with one hand? /// 1133B Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B.2.5 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the revolving do turnstile to facilitate the same use pattern? , /// 1133B Yes, other than Adjust do do pressures and pressures as signage. required this is an on-going maintenance issue. See Fm 10 Building Entrances and Exits EN1 Main Entry EN2 Rear Exit Page 1 of 4

41 BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 28 Liberty Ship Way Main Crids : IR1 : 1 st & 2nd : Other Do Do crid dos comply with all applicable requirements of Survey Fm 11 - Dos and Gates? 404 /// 1133B Directional and Infmational Room/ Identification Tactile Exit Tactile Exit Tactile Exit Do signs which provide direction to, infmation about, functional spaces of the building comply with the requirement f visual signage? EXCEPTION: Building directies, menus, and all other signs which are tempary are not required to comply. 216 /// 1117B.5.1 item 2 Do signs which identify permanent rooms and spaces comply with the visual and tactile/braille requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B.5.7 See individual suite do surveys. Page 2 of 4

42 BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 28 Liberty Ship Way Main Crids : IR1 : 1 st & 2nd : Raised and Braille Characters Character Size Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B.5.6 Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Counter Height Counter Knee Changes in Level Protruding Objects Does signage comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 At reception, transaction, security counters, is there a ption of the main counter at least 36 long and no me than 34 high? 227, /// 1122B.4 Where seated service at a counter is provided, is the knee space at least 27 high, 30 wide, and 19 deep? /// 1122B.3 Are ramps elevats used f changes in level greater than 1/2"? (Platfm lifts may only be used in certain limited situations.) /// 1124B.2 If objects mounted to the wall have leading edges between 27 and 80 from the flo, do they project less than 4 into the circulation path? (Wall mounted objects with leading edges at below 27 may project any amount so long as the required clear width of an accessible route is not reduced.) 307 /// 1133B Head room Is there at least 80 clear head room within the pedestrian circulation area, including the accessible route of travel? /// 1133B Alarms If emergency warning systems are provided, do they include both audible alarms and visual alarms complying with Survey Fm 20 - Alarms? 215 /// , , 1114B.2.2 Head room protected by a curb and the underside is not in the path of travel at the main circular stair. Fire Alarm System not surveyed. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, Reach Range Page 3 of 4

43 BUILDING LOBBIES AND CORRIDORS (Interi Accessible Route) Survey Fm 12 /Room Name: 28 Liberty Ship Way Main Crids : IR1 : 1 st & 2nd : Other NOTES: Page 4 of 4

44 ELEVATORS Survey Fm 13 /Room Name: 28 Liberty Ship Way, Elevat IR1 : Elevat : : 13.1 Multi-level Building Does an elevat serve each level, including mezzanines? F exceptions see 1103B.1. (If a ramp a platfm lift is provided instead, use Survey Fm 7 - Ramps and Survey Fm 9 - Platfm Lifts.) /// 1103B Elevats If me than one elevat is provided in a building, does each full passenger elevat comply with the requirements below? 206.6, /// 1103B Hizontal Gap Is the hizontal gap between the car flo platfm and the landing edge no greater than 1-1/4? /// 1116B Hallway Call Buttons 13.5 Visual Indicats Are the hallway call buttons centered at 42 above the flo and are the buttons at least 3/4 in the smallest dimension? , /// 1116B.1.10 Do the buttons have visual signals to indicate when each call is registered and answered and are the buttons raised flush (not recessed)? , /// 1116B Hall Lanterns Is there a visible and audible signal at each hoistway entrance to indicate which car is answering a call and direction of travel? /// 1116B Audible Signals Do audible signals sound once f "up" and twice f "down," do they have verbal annunciats that say "up" "down"? /// 1116B Visible Signals Are visible signals also provided and are they: Mounted so that the centerline is at least 72 AFF; At least 2-1/2 in the smallest dimension; and, visible from the vicinity of the hall call button? /// 1116B.1.13, Fig. 11B-40C 13.9 Do Jamb - Raised Characters Do Jamb - Braille Does each elevat hoistway entrance have raised flo designation letters numerals, sans serif simple serif type, 2 high on each do jamb centered 60 AFF, and do the signs f the main entry flo include a raised star? /// 1116B.1.14 Is Grade 2 Braille placed below the cresponding raised characters symbols? /// 1116B.1.14, 1117B Dos Do the dos re-open automatically without contact if an obstruction passes through the opening between 5 and 29 above the flo? /// 1116B Do Opening Is the clear opening at elevat dos at least 36? /// 1116B Car Inside Does the flo area of the car allow maneuvering room f wheelchair users to enter the car, reach the controls, turn, and exit? /// 1116B /8 42-1/4 on center Chimes once f both directions. 42 Page 1 of 3

45 ELEVATORS Survey Fm 13 /Room Name: 28 Liberty Ship Way, Elevat IR1 : Elevat : : Center Opening Car Dos Side-slide Opening Car Dos At cars with center opening dos, is the clear distance between walls between wall and do, excluding return panels, at least 80 by 54, and is the distance from wall to return panel at least 51 clear? Fig (a) /// 1116B.1.8, Fig 11B-40A At cars with side-slide opening dos, is the clear distance between walls between wall and do, excluding return panels, at least 68 by 54, and is the distance from wall to return panel at least 51 clear? Fig (b) /// 1116B.1.8, Fig 11B-40A Handrail Is there a handrail installed at 32 AFF (+/-1 ), on at least one wall of the car? /// 1116B Car Control Buttons Car Controls - Raised Characters Car Controls - Character Height Car Controls - Braille Car Controls - Contrast Car Controls Main Entry Designation Are the car control buttons at least 3/4 in their smallest dimension, raised with square edges, and self-illuminated? /// 1116B.1.9 Are the controls designated by raised letters and/ numerals, standard elevat symbols that are placed immediately to the left of the buttons? /// 1116B.1.9 Are these raised characters upper case, sans serif simple serif, and at least 5/8 high? /// 1116B.1.9 Is Grade 2 Braille placed below the cresponding raised characters symbols? /// 1116B.1.9, 1117B.5.6 Are the raised characters white on a black background? /// 1116B.1.9 Is the button f the main entry flo designated by a raised star? /// 1116B Buttons Do the flo buttons have visual indicats to show when each call is registered and are they extinguished when each call is answered? /// 1116B Height of Car Controls Emergency Car Controls Car Control Location Are the flo buttons no higher than 54 AFF f side approach and no higher than 48 when only front approach is possible? /// 1116B.1.8 Are the emergency controls grouped at the bottom of the panel with centerlines no less than 35 AFF? /// 1116B.1.8 If the cars have center opening dos, are the controls located on the front wall? OR If the cars have side-slide opening dos are the controls located on the side front wall adjacent to the dos? /// 1116B.1.6, Fig 11B-40A 54-1/2 x /2 to top 41-3/4 Page 2 of 3

46 ELEVATORS Survey Fm 13 /Room Name: 28 Liberty Ship Way, Elevat IR1 : Elevat : : Emergency Communication Emergency Communication Emergency Communication Is there an emergency two-way communication system between the elevat and a point outside the hoistway provided? /// 1116B.1.8 Is the highest operable part of the communication system no higher than 48 AFF, and if the system uses a handset, is the length of the cd from the panel to the handset at least 29? /// 1116B.1.8 Is the 2-way communication system usable without voice communication? /// 1116B Controls If the communication system is in a closed compartment, is the hardware on the compartment do operable with one hand, and without tight grasping, pinching, twisting of the wrist? /// 1116B.1.8, 1117B.6 item Other NOTES: Page 3 of 3

47 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2810 : RS1 : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? , /// 1133B.2.3.3; 1133B Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? /// 1133B , 1133B.2.2, 1133B Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? /// 1133B Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? /// 1133B Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Exteri slopes at 2.1% - 2.4% Page 1 of 3

48 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2810 : RS1 : 1 : Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) /// 1133B Hardware Is any operating hardware mounted between 30 and 44 above the flo? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? /// 1133B Room/ Identification Tactile Exit Tactile Exit Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 Exteri OK Interi office had knob style. >20 lbs Adjust closer. Install EXIT sign per requirements below. Page 2 of 3

49 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2810 : RS1 : 1 : Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B Other 1 st Crid do to this area is alarmed and was not surveyed. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, NOTES: 2810 is a private lease space and was surveyed f an accessible exteri entrance/exit only. Page 3 of 3

50 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do A : RS2 - A : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? , /// 1133B.2.3.3; 1133B Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? /// 1133B , 1133B.2.2, 1133B Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? /// 1133B Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? /// 1133B Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Exteri slopes at 2.4% - 2.8% Page 1 of 3

51 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do A : RS2 - A : 1 : Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) /// 1133B Hardware Is any operating hardware mounted between 30 and 44 above the flo? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? /// 1133B Room/ Identification Tactile Exit Tactile Exit Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 16 lbs Adjust closer. Install EXIT sign per requirements below. Page 2 of 3

52 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do A : RS2 - A : 1 : Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B Other If one of the exteri dos is used as a public entrance to the suite, install an ISA sign. NOTES: Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, See SF10 EN1, 10.2 Page 3 of 3

53 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do B : RS2 - B : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? , /// 1133B.2.3.3; 1133B Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? /// 1133B , 1133B.2.2, 1133B Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? /// 1133B Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? /// 1133B Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Exteri slopes at 2.1% - 2.3% Page 1 of 3

54 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do B : RS2 - B : 1 : Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) /// 1133B Hardware Is any operating hardware mounted between 30 and 44 above the flo? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? /// 1133B Room/ Identification Tactile Exit Tactile Exit Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 22 lbs Adjust closer. Install EXIT sign per requirements below. Page 2 of 3

55 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do B : RS2 - B : 1 : Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B Other If one of the exteri dos is used as a public entrance to the suite, install an ISA sign. NOTES: Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, See SF10 EN1, 10.2 Page 3 of 3

56 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do C : RS2 - C : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? , /// 1133B.2.3.3; 1133B Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? /// 1133B , 1133B.2.2, 1133B Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? /// 1133B Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? /// 1133B Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Refer to Survey Fm 12 Building Lobbies and Crids: IR1. Page 1 of 3

57 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do C : RS2 - C : 1 : Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) /// 1133B Hardware Is any operating hardware mounted between 30 and 44 above the flo? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? /// 1133B Room/ Identification Tactile Exit Tactile Exit Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 17 lbs Adjust closer. Install EXIT ROUTE sign per requirements below. Page 2 of 3

58 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do C : RS2 - C : 1 : Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, Other NOTES: Page 3 of 3

59 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do D : RS2 - D : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? , /// 1133B.2.3.3; 1133B Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? /// 1133B , 1133B.2.2, 1133B Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? /// 1133B Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? /// 1133B Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Refer to Survey Fm 12 Building Lobbies and Crids: IR1. Page 1 of 3

60 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do D : RS2 - D : 1 : Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) /// 1133B Hardware Is any operating hardware mounted between 30 and 44 above the flo? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? /// 1133B Room/ Identification Tactile Exit Tactile Exit Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 13 lbs Adjust closer. Install EXIT ROUTE sign per requirements below. Page 2 of 3

61 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2815 Do D : RS2 - D : 1 : Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, Other NOTES: Page 3 of 3

62 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2830 Do A : RS3 - A : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? , /// 1133B.2.3.3; 1133B Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? /// 1133B , 1133B.2.2, 1133B Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? /// 1133B Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? /// 1133B Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Refer to Survey Fm 12 Building Lobbies and Crids: IR1. Page 1 of 3

63 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2830 Do A : RS3 - A : 1 : Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) /// 1133B Hardware Is any operating hardware mounted between 30 and 44 above the flo? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? /// 1133B Room/ Identification Tactile Exit Tactile Exit Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 >10 lbs Adjust closer. Install room identification signage per requirements below. Page 2 of 3

64 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2830 Do A : RS3 - A : 1 : Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, Other NOTES: Page 3 of 3

65 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2830 Do B : RS3 - B : 1 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? , /// 1133B.2.3.3; 1133B Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? /// 1133B , 1133B.2.2, 1133B Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? /// 1133B Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? /// 1133B Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Exteri slopes at 2.1% - 2.3%. Page 1 of 3

66 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2830 Do B : RS3 - B : 1 : Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) /// 1133B Hardware Is any operating hardware mounted between 30 and 44 above the flo? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? /// 1133B Room/ Identification Tactile Exit Tactile Exit Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 >15 lbs Do latch sticks. Adjust closer. Repair accdingly. Install EXIT sign if this do is to be used as an exit. Page 2 of 3

67 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2830 Do B : RS3 - B : 1 : Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, Other NOTES: This space is currently being used as a stage area and the exteri do is kept locked. Page 3 of 3

68 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2830 : RS5 : 2 : 11.1 Accessible s 11.2 Accessible Routes 11.3 Revolving Dos and Turnstiles Is there at least one accessible do complying with the requirements below at each accessible space in the facility? /// 1133B.2 Does each do that is an element of an accessible route comply with the requirements below? 404 /// 1114B.1.1 If a revolving do turnstile is used on an accessible route, is an accessible do gate provided adjacent to the turnstile revolving do to facilitate the same use pattern? , /// 1133B.2.3.3; 1133B Gates Do gates, including ticket gates, meet all applicable specifications of dos? 404 /// 1133B Clear Opening When a do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the do stop on the latch side? At double dos does at least one do leaf comply? /// 1133B , 1133B.2.2, 1133B Do Maneuvering 11.7 Maneuvering 11.8 Vestibules - Dos in Series 11.9 Vestibules - Dos in Series If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 24 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 18 at interi dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B.2.4 If there are two dos in a series, is the clear space between dos in a vestibule at least 48 plus the width of any do swinging into the space? /// 1133B Do dos in a series swing in the same direction? OR Do they swing away from the space between the dos? /// 1133B Thresholds Are the thresholds at doways no higher than 1/2? Are changes in level between 1/4 and 1/2 beveled at 1:2 less? /// 1133B Refer to Survey Fm 12 Building Lobbies and Crids: IR1. Install signage and adjust do closer. Page 1 of 3

69 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2830 : RS5 : 2 : Hardware Are all handles, locks, and latches other operative devices operable with one hand, and are they operable without tight grasping, pinching, twisting of the wrist? (Levers and push/pull type mechanisms are acceptable designs.) /// 1133B Hardware Is any operating hardware mounted between 30 and 44 above the flo? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Kick Plate Does the bottom 10 of all dos except automatic and sliding have a smooth, uninterrupted surface on the push side to allow the do to be opened by a wheelchair footrest without creating a trap hazardous condition? /// 1133B Powered Dos If a power-assisted do is used, does it have an opening fce of 5 lbs less and does such do require no me than 15 lbs to stop do movement? /// 1133B Room/ Identification Tactile Exit Tactile Exit Tactile Exit If there is a sign designating a permanent room space, does it comply with the requirements below? /// 1117B.5.1 item 1 At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 18 lbs Adjust closer. Install room identification signage per requirements below. Page 2 of 3

70 DOORS AND GATES Survey Fm 11 /Room 28 Liberty Ship Way Name: Suite 2830 : RS5 : 2 : Tactile Exit At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does the sign comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B.5 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, Other NOTES: Page 3 of 3

71 ROOMS AND SPACES Survey Fm 14 /Room 28 Liberty Ship Way Name: Suite 2800 : RS4 : 2nd : 14.1 Accessible Route 14.2 Clear Do Opening 14.3 Do Maneuvering 14.4 Maneuvering Is there an accessible route of travel connecting the room space to an accessible entrance within the building? /// 1114B.1.2 When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? /// 1133B , 1133B.2.2 If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26 Is the flo level (2% max) and clear within the required maneuvering space? /// 1133B Do Hardware Are all handles, locks, and latches other operative devices operable with one hand? /// 1133B Do Operating Efft Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B.2.5 Refer to Survey Fm 12 Building Lobbies and Crids: IR1. Main Entry Exit Stair Do Main Entry Exit Stair Do Main Entry Exit Stair Do Main Entry Exit Stair Do 14.7 Do Closers If the do has a closer, is the closer adjusted so that Speed OK from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B Room/ If there is a sign designating the permanent room Identification space, does it comply with the requirements below? /// 1117B.5.1 item Tactile Exit At each grade level exteri exit do is there a tactile/braille exit sign with the wd EXIT mounted on the wall adjacent to the latch side of the do? /// item 1 >20 lbs Adjust closer at all dos. Page 1 of 4

72 ROOMS AND SPACES Survey Fm 14 /Room 28 Liberty Ship Way Name: Suite 2800 : RS4 : 2nd : Tactile Exit Tactile Exit Tactile Exit At each exit do leading to a grade-level exteri exit by means of a stairway ramp, is there a tactile/braille exit sign with the wds EXIT STAIRS DOWN ( UP) EXIT RAMP DOWN ( UP) mounted on the wall adjacent to the latch side of the do? /// item 2 At each exit do that leads to a grade-level exteri exit by means of an exit enclosure that does not utilize a stair ramp, by means of an exit passageway, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item 3 At each exit access do from an interi room area that is required to have a visual exit sign, is there a tactile/braille exit sign with the wds EXIT ROUTE mounted on the wall adjacent to the latch side of the do? /// item Side of Dos Are permanent identification signs located on the approach side of the do as one enters the room space? Are exit signs located on the approach side of the do as one exits the room space? /// 1117B Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Exit Stair Do Page 2 of 4

73 ROOMS AND SPACES Survey Fm 14 /Room 28 Liberty Ship Way Name: Suite 2800 : RS4 : 2nd : Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Does signage comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B Aisles Are aisles at least 36 wide when serving cross aisles on one side only? OR Are aisles at least 44 wide when serving cross aisles on both sides? /// 1133B U-Turn Where the accessible route of travel makes a U-turn around an obstacle which is less than 48 wide, is the accessible route at least 42 wide on the approaches and 48 wide in the turn? /// Fig 11B-5E Surface Are the flo surfaces on the accessible route of travel stable, firm, and slip-resistant? /// 1124B Carpet Where carpet is provided, is it low pile type (< 1/2 ) with a firm pad no pad underneath? /// 1124B.3, Figure 11B-7E Level Changes At level changes, is the vertical distance < 1/4? OR Are changes in level between 1/4 and 1/2 beveled with a slope no greater than 1:2? 303.2, /// 1124B.2; 1133B Level Changes When flo materials change, does the vertical distance between them meet the above requirement? 303 /// 1124B; 1133B Level Changes Are ramps elevats used f changes in level greater than 1/2"? (Lifts may only be used in certain limited situations.) /// 1124B Fixed/Built-in Seating, Tables Counters At fixed built-in seating, tables, counters in public common employee areas, are 5% (but not less than one) of the provided seating spaces wheelchair accessible and have a 30 by 48 clear space which overlaps an accessible route of travel? 226, 902 /// 1122B.4, 1125B Knee Is the knee space at least 27 high, 30 wide, and 19 deep? /// 1122B.3 Crids ok. Wk areas/cubicles not surveyed. Receptionist Counter at 36-1/4 ; however this is a wk area, not a counter that conducts business transactions with the public. Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, Page 3 of 4

74 ROOMS AND SPACES Survey Fm 14 /Room 28 Liberty Ship Way Name: Suite 2800 : RS4 : 2nd : Protruding Objects If objects mounted to the wall have leading edges between 27 and 80 from the flo, do they project less than 4 into the circulation path? (Wall mounted objects with leading edges at below 27 may project any amount so long as the required clear width of an accessible route is not reduced.) /// 1133B Head room Is there at least 80 clear head room within the pedestrian circulation area, including the accessible route of travel? /// 1133B Controls Are controls, dispensers, and similar devices between 15 and 48 AFF when the clear flo space allows a fward parallel approach? /// 1117B.6 item Electrical Switches Electrical Receptacle Outlets Are controls and switches located no me than 48 measured from the top of the outlet box n less than 15 measured from the bottom of the outlet box AFF? /// 1117B.6 item 5.1 Are all electrical and communications receptacles at least 15 and not me than 48 above the finish flo? /// 1117B Controls Are controls operable with one hand, and without tight grasping, pinching, twisting of the wrist and is the fce required to activate controls less than 5 lbs? /// 1117B.6 item Kitchen Counter If provided in public common employee use areas are countertops and sinks mounted no me than 34 AFF? /// 1117B.9, 1122B Sink Is the knee space under the sink at least 27 high, 30 wide, and 19 deep? /// 1115B.4.7 item Faucet Operation Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? /// 1115B.4.7 item Alarms If emergency warning systems are provided, do they include both audible alarms and visual alarms complying with Survey Fm 20 - Alarms? 215 /// , , 1114B.2.2 Not Surveyed 34-1/4 Garbage disposal interferes with required knee space. Fire Alarm System not surveyed Other - NOTES: Wk Area surveyed general access path only. Page 4 of 4

75 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? /// 1115B.1.1 Is the toilet room located on an accessible route of travel? /// 1115B Entry Dos Does the do comply with the requirements below? 404 /// 1115B Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? /// 1133B Do Swing Does the do swing not intrude into the clear flo space at any fixture? /// 1115B Do Maneuvering 16.9 Do Hardware Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? /// 1133B Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B >20 lbs Adjust closer. Page 1 of 8

76 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : Identification Symbols Identification Symbols Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? /// 1117B.5.1 item Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? /// 1117B.5.1 item Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? /// 1117B.5.5 item ISA If the toilet room is accessible, is the room identified by an ISA? /// 1117B.5.1 item Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B Page 2 of 8

77 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B Surface Is the surface of the toilet room stable, firm, and slip resistant? /// 1124B Maneuvering Maneuvering Maneuvering Stall Do Width Stall Do Width Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.) /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? /// 1115B.3.1 item Stall Do Is the stall do self-closing? /// 1115B.3.1 item Stall Do Strike Edge Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? /// 1115B.3.1 item Stall Width Is the stall at least 60 wide? /// 1115B.3.1 item 4.1 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, /2 Clear Hardware on pull side only. Page 3 of 8

78 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : Stall Maneuvering Stall Maneuvering Stall Maneuvering Stall Do Location Maneuvering Maneuvering WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? /// 1115B.3.1 item 4.2 If the stall has an in-swinging side entry stall do, is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep space f flo-mounted WC? (Toilet compartment dos shall not swing into the minimum required compartment area.) , /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? /// 1115B.4.1 item WC Seat Is the top of the WC seat between 17 and 19 AFF? /// 1115B.4.1 item WC Flush Controls Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? /// 1115B.4.1 item 5 The length of the stall is long enough to accommodate the 56 clear compartment space; however there is a 6 stile installed on the hinge side of the compartment do which reduces the required compartment depth to 54. See photo and sketch below. Reconfigure compartment by lengthening the partition adjacent to the toilet to achieve 56 minimum clear from the rear wall. Reduce stile size at the hinge side of compartment do /4 at front 17-3/4 at rear Can WC be adjusted? 19-1/4 on LH side Page 4 of 8

79 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : Toilet Paper Dispenser Toilet Paper Dispenser Toilet Paper Dispenser Seat Cover Dispenser Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? /// 1115B.8.4 Does the toilet paper dispenser allow continuous paper delivery? /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A Grab Bar Diameter Grab Bar Wall Clearance Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? /// **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? /// 1115B Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? /// 1115B.4.1 item from back wall. 17 to center line of dispenser from the front of the water closet. Bottom roll 21 AFF; top roll 29 AFF. Recessed toilet paper and seat cover dispenser will need to be relocated to meet requirements. Currently mounted too high (f seat cover dispenser) and too far away from the water closet f the toilet paper dispenser. 41 See above. 33-1/4 Install grab bars at 33 o.c. AFF. 50 from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 8

80 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? /// 1115B.4.1 item Semi- Ambulant Stall Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? /// 1115B.3.1 item 5, 1115B.4.1 item Urinals Where urinals are provided, does at least one comply with the requirements below? /// 1115B Urinal Rim Height Clear at Urinal Width Between Screens at Urinal Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, /// 1118B.4 item 2, Fig. 11B-5A(b) Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? /// 1115B Lavaty Rim Height Lavaty Apron Clearance Lavaty Knee Clearance Lavaty Wall ion Clear at Lavaty Side Clearance at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Page 6 of 8

81 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : Lavaty Location Pipe Insulation at Lavaty Smooth Surfaces at Lavaty Faucet Operation at Lavaty Faucet Operation at Lavaty Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? /// 1115B.4.3 item 1 If the valve is self-closing, does it remain open f at least 10 seconds? /// 1115B.4.3 item Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? /// 1115B Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? /// 1117B Dispensers Operating Height at Dispensers Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// , , 1114B /8 Paper towel: OK Soap: OK Sanitary Napkin Dispenser: OK Other slopes are good. NOTES: Page 7 of 8

82 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 1 st : TR1 : 1st : Code Clearance Typical f Men s and Women s accessible stall both flos. Page 8 of 8

83 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 1st : TR2 : 1st : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? /// 1115B.1.1 Is the toilet room located on an accessible route of travel? /// 1115B Entry Dos Does the do comply with the requirements below? 404 /// 1115B Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? /// 1133B Do Swing Does the do swing not intrude into the clear flo space at any fixture? /// 1115B Do Maneuvering 16.9 Do Hardware Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? /// 1133B Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B >10 lbs Adjust closer. Page 1 of 8

84 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 1st : TR2 : 1st : Identification Symbols Identification Symbols Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? /// 1117B.5.1 item Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? /// 1117B.5.1 item Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? /// 1117B.5.5 item ISA If the toilet room is accessible, is the room identified by an ISA? /// 1117B.5.1 item Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B /4 Page 2 of 8

85 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 1st : TR2 : 1st : Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B Surface Is the surface of the toilet room stable, firm, and slip resistant? /// 1124B Maneuvering Maneuvering Maneuvering Stall Do Width Stall Do Width Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.) /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? /// 1115B.3.1 item Stall Do Is the stall do self-closing? /// 1115B.3.1 item Stall Do Strike Edge Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? /// 1115B.3.1 item Stall Width Is the stall at least 60 wide? /// 1115B.3.1 item 4.1 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, /2 Clear Hardware on pull side only. 59-3/4 Page 3 of 8

86 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 1st : TR2 : 1st : Stall Maneuvering Stall Maneuvering Stall Maneuvering Stall Do Location Maneuvering Maneuvering WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? /// 1115B.3.1 item 4.2 If the stall has an in-swinging side entry stall do, is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep space f flo-mounted WC? (Toilet compartment dos shall not swing into the minimum required compartment area.) , /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? /// 1115B.4.1 item WC Seat Is the top of the WC seat between 17 and 19 AFF? /// 1115B.4.1 item WC Flush Controls Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? /// 1115B.4.1 item /4 wide Depth ok. The length of the stall is long enough to accommodate the 56 clear compartment space; however there is a 6 stile installed on the hinge side of the compartment do which reduces the required compartment depth to 54. See photo and sketch below. Reconfigure compartment by lengthening the partition adjacent to the toilet to achieve 56 minimum clear from the rear wall. Reduce stile size at the hinge side of compartment do /2 18 Page 4 of 8

87 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 1st : TR2 : 1st : Toilet Paper Dispenser Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? /// 1115B /4 from back wall. Bottom roll: 20 AFF Top roll: 28 AFF Toilet Paper Dispenser Toilet Paper Dispenser Seat Cover Dispenser **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? /// 1115B.8.4 Does the toilet paper dispenser allow continuous paper delivery? /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A Grab Bar Diameter Grab Bar Wall Clearance Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? /// 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? /// 1115B Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? /// 1115B.4.1 item from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 8

88 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 1st : TR2 : 1st : Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? /// 1115B.4.1 item Semi- Ambulant Stall Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? /// 1115B.3.1 item 5, 1115B.4.1 item Urinals Where urinals are provided, does at least one comply with the requirements below? /// 1115B Urinal Rim Height Clear at Urinal Width Between Screens at Urinal Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, /// 1118B.4 item 2, Fig. 11B-5A(b) Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? /// 1115B Lavaty Rim Height Lavaty Apron Clearance Lavaty Knee Clearance Lavaty Wall ion Clear at Lavaty Side Clearance at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item /2 from wall, 16 AFF 35-1/2 35-1/2 34-3/4 & 34-5/8 Lower counter and sinks. 30 Page 6 of 8

89 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 1st : TR2 : 1st : Lavaty Location Pipe Insulation at Lavaty Smooth Surfaces at Lavaty Faucet Operation at Lavaty Faucet Operation at Lavaty Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? /// 1115B.4.3 item 1 If the valve is self-closing, does it remain open f at least 10 seconds? /// 1115B.4.3 item Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? /// 1115B Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? /// 1117B Dispensers Operating Height at Dispensers Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// , , 1114B /2 Paper towel: OK Other slope is good. NOTES: Page 7 of 8

90 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 1st : TR2 : 1st : Code Clearance Typical f Men s and Women s accessible stall both flos. Page 8 of 8

91 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? /// 1115B.1.1 Is the toilet room located on an accessible route of travel? /// 1115B Entry Dos Does the do comply with the requirements below? 404 /// 1115B Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? /// 1133B Do Swing Does the do swing not intrude into the clear flo space at any fixture? /// 1115B Do Maneuvering 16.9 Do Hardware Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? /// 1133B Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B >15 lbs Adjust closer. Page 1 of 8

92 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : Identification Symbols Identification Symbols Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? /// 1117B.5.1 item Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? /// 1117B.5.1 item Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? /// 1117B.5.5 item ISA If the toilet room is accessible, is the room identified by an ISA? /// 1117B.5.1 item Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B /2 Page 2 of 8

93 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B Surface Is the surface of the toilet room stable, firm, and slip resistant? /// 1124B Maneuvering Maneuvering Maneuvering Stall Do Width Stall Do Width Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.) /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? /// 1115B.3.1 item Stall Do Is the stall do self-closing? /// 1115B.3.1 item Stall Do Strike Edge Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? /// 1115B.3.1 item Stall Width Is the stall at least 60 wide? /// 1115B.3.1 item 4.1 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, /2 Clear Hardware on pull side only. Page 3 of 8

94 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : Stall Maneuvering Stall Maneuvering Stall Maneuvering Stall Do Location Maneuvering Maneuvering WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? /// 1115B.3.1 item 4.2 If the stall has an in-swinging side entry stall do, is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep space f flo-mounted WC? (Toilet compartment dos shall not swing into the minimum required compartment area.) , /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? /// 1115B.4.1 item WC Seat Is the top of the WC seat between 17 and 19 AFF? /// 1115B.4.1 item WC Flush Controls Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? /// 1115B.4.1 item 5 The length of the stall is long enough to accommodate the 56 clear compartment space; however there is a 6 stile installed on the hinge side of the compartment do which reduces the required compartment depth to 54. See photo and sketch below. Reconfigure compartment by lengthening the partition adjacent to the toilet to achieve 56 minimum clear from the rear wall. Reduce stile size at the hinge side of compartment do /4 Page 4 of 8

95 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : Toilet Paper Dispenser Toilet Paper Dispenser Toilet Paper Dispenser Seat Cover Dispenser Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? /// 1115B.8.4 **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? /// 1115B.8.4 Does the toilet paper dispenser allow continuous paper delivery? /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A Grab Bar Diameter Grab Bar Wall Clearance Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? /// 43 from back wall. 17 to center line of dispenser from the front of the water closet. Bottom roll: 20-1/2 AFF Top roll: 28-1/2 AFF Recessed toilet paper and seat cover dispenser will need to be relocated to meet requirements. Currently mounted too far away from the water closet f the toilet paper dispenser. 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? /// 1115B Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? /// 1115B.4.1 item from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 8

96 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? /// 1115B.4.1 item Semi- Ambulant Stall Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? /// 1115B.3.1 item 5, 1115B.4.1 item Urinals Where urinals are provided, does at least one comply with the requirements below? /// 1115B Urinal Rim Height Clear at Urinal Width Between Screens at Urinal Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, /// 1118B.4 item 2, Fig. 11B-5A(b) Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? /// 1115B Lavaty Rim Height Lavaty Apron Clearance Lavaty Knee Clearance Lavaty Wall ion Clear at Lavaty Side Clearance at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item 2 Page 6 of 8

97 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : Lavaty Location Pipe Insulation at Lavaty Smooth Surfaces at Lavaty Faucet Operation at Lavaty Faucet Operation at Lavaty Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? /// 1115B.4.3 item 1 If the valve is self-closing, does it remain open f at least 10 seconds? /// 1115B.4.3 item Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? /// 1115B Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? /// 1117B Dispensers Operating Height at Dispensers Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// , , 1114B Other Slope to flo drain at 2.7%. Should not exceed 2% in any direction. 37-5/8 Paper towel: OK Soap: OK Sanitary Napkin Dispenser: Coin slot at 42 Lower sanitary napkin dispenser so that all operable parts are no higher than 40.. NOTES: Page 7 of 8

98 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Women s Restroom 2nd : TR3 : 2nd : Code Clearance Typical f Men s and Women s accessible stall both flos. Page 8 of 8

99 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : 16.1 Toilet Rooms If toilet rooms are provided, does each public and common use toilet room comply with the requirements below? (A common use toilet room is used f a restricted group of people such as occupants of a building employees of a company.) 603 /// 1115B Gender Separate Toilet Rooms 16.3 Unisex Toilet Rooms 16.4 Accessible Route of Travel Where separate facilities are provided f persons of each sex, are these facilities accessible? /// 1115B.1.1 Where unisex facilities are provided are these facilities accessible? /// 1115B.1.1 Is the toilet room located on an accessible route of travel? /// 1115B Entry Dos Does the do comply with the requirements below? 404 /// 1115B Clear Do Opening When the do is open 90 degrees, is there a clear opening width at least 32 measured between the face of the do and the dostop on the latch side? /// 1133B Do Swing Does the do swing not intrude into the clear flo space at any fixture? /// 1115B Do Maneuvering 16.9 Do Hardware Do Operating Efft If the do is not automatic power assisted, does it have maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26? Approach Side Width Depth Front Pull D + 18 * 60 Front Push D + 0 ** 48 Latch Pull D Latch Push D *** Hinge Pull D Hinge Push 54 **** 44 ***** * D + 24 at exteri dos. ** D + 12 if do has both a latch and a closer. *** 48 if do has closer. **** Measured from latch toward hinge. ***** 48 if do has both a latch and a closer /// 1133B.2.4.2, Fig. 11B-26A & 11B-26B Are all handles, locks, and latches other operative devices operable with one hand? /// 1133B Is the fce required to operate a do no greater than 5 lbs? (Required fire dos shall have the minimum opening fce allowable by the appropriate administrative authity, not to exceed 15 lb.) /// 1133B Do Closers If the do has a closer, is the closer adjusted so that from an open position of 70 degrees, the do will take at least 3 seconds to move to a point 3 from the latch (measured to the leading edge of the do)? /// 1133B lbs Adjust closer. Page 1 of 8

100 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : Identification Symbols Identification Symbols Room/ Identification Is each doway leading to a men s toilet room identified by an equilateral triangle 1/4" thick with edges 12 long, and is each women s toilet room identified by a circle, 1/4" thick and 12 in diameter? (Unisex facilities shall be identified by a 12 circle, 1/4" with a 1/4" thick triangle superimposed and within the circle.) /// 1115B.6 Is the geometric symbol centered on the do leaf at a height of 60 and is the symbol s col and contrast distinctly different from the col and contrast of the do? /// 1115B.6 In addition, is there a tactile room identification sign complying with the requirements below? /// 1117B.5.1 item Gender Is the gender indicated on the sign by raised letters (men s, women s, boys, girls )? /// 1117B.5.1 item Pictogram Is there a gender pictogram provided directly above the raised letters (pictograms are optional)? /// 1117B.5.5 item ISA If the toilet room is accessible, is the room identified by an ISA? /// 1117B.5.1 item Mounting Location Are tactile signs mounted on the wall adjacent to the latch side of the do and located 48 minimum above the finished flo, measured from the baseline of the lowest line of Braille; and 60 maximum above the finish flo, measured from the baseline of the highest line of raised characters (At double leaf dos, are the signs placed on the nearest adjacent wall?) /// 1117B Approach Are signs containing tactile characters located so that a clear flo space of 18 minimum, centered on the tactile characters, is provided beyond the arc of any do swing? Can a person approach to within 3 of tactile signs without encountering protruding objects standing within the swing of the do? /// 1117B Raised and Braille Characters Are the characters on tactile signs accompanied by Grade 2 Braille? Is the Braille placed a min. of 3/8 and a max. of 1/2 below the tactile characters, flush left centered? If the tactile text is multi-lined, is all Braille placed together below all lines of tactile text? Are the dots within each Braille cell 1/10 o.c.? /// 1117B.5.5 items 1& 4, 1117B Character Size Are the raised characters on tactile signs between 5/8 and 2 high and raised at least 1/32? , /// 1117B.5.5 items 1 & Upper Case Are the raised characters on tactile signs upper case, and sans serif simple serif? , /// 1117B /2 Page 2 of 8

101 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : Contrast Do the characters on signs contrast with their background (light-on-dark dark-on-light) and do the signs have a non-glare finish? /// 1117B Other Identification Signage Do signs comply with all applicable requirements of Survey Fm 19 - Signage? 703 /// 1117B Surface Is the surface of the toilet room stable, firm, and slip resistant? /// 1124B Maneuvering Maneuvering Maneuvering Stall Do Width Stall Do Width Stall Do Hardware Is there an unobstructed turning space (a 60 diameter circle T-shaped space) in the toilet room? (The clear flo space of fixtures and controls, the accessible route of travel, and the turning space may overlap.) /// 1115B.3.1 1, 1115B.3.2 item 1 Other than the do to the accessible WC compartment, no do, in any position, encroaches into this turning space f me than /// 1115B.3.1 1, 1115B.3.2 item 1 Are the accessible fixtures and controls on an unobstructed accessible path? /// 1115B.1 In front entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 32 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 In side entry stalls: When the stall do is open 90 degrees, is there a clear opening of at least 34 measured between the face of the do and the edge of the partition on the latch side? /// 1115B.3.1 item 4.4 Does the stall do have U-pulls on both sides and a locking mechanism operable with one hand without tight grasping, pinching, twisting of the wrist? /// 1115B.3.1 item Stall Do Is the stall do self-closing? /// 1115B.3.1 item Stall Do Strike Edge Approach Aisle to Stall If the stall do opens out at the end of an aisle, is there at least 18 of maneuvering space at the latch side of the stall do? /// 1115B.3.1 item 4.5 If the stall do swings out, is the aisle approaching the stall at least 60 wide? /// 1115B.3.1 item Stall Width Is the stall at least 60 wide? /// 1115B.3.1 item 4.1 Provide signage per 2010 ADA requirements and CBC Emergency Regulations dated July 1, /2 Clear Hardware on pull side only. 59-3/4 Page 3 of 8

102 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : Stall Maneuvering Stall Maneuvering Stall Maneuvering Stall Do Location Maneuvering Maneuvering WC not in Stalls If the stall has a side entry stall do, is there a 60 by 60 clear flo space in front of the WC? /// 1115B.3.1 item 4.2 If the stall has an in-swinging side entry stall do, is there a 60 min wide by 56 min deep space f a wallmounted WC, a 60 min wide by 59 min deep space f flo-mounted WC? (Toilet compartment dos shall not swing into the minimum required compartment area.) , /// Fig 11B-1B If the stall has an end entry stall do, is there at least a 60 wide by 48 deep clear flo space in front of the WC? /// 1115B.3.1 item 4.3 If the stall has an end entry stall do, is the stall do located in front of the clear flo space - diagonal to the WC - with a maximum stile width of 4 inches? /// 1115B.3.1 item 4.3 Is there a minimum 32 wide clear flo space from a wall at one side of the WC to allow a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If there is another fixture alongside the toilet, is there a clear flo space at least 28 wide to allow f a side transfer? /// 1115B.4.1 item 1, Fig. 11B-1A If the WC is not in a stall, is there a clear flo space at least 60 wide by 48 deep in front of the WC to allow f a front transfer? /// 1115B.4.1 item 2, Fig. 11B-1A WC Location Is the centerline of the WC a minimum of 16 and a maximum of 18 from a wall partition? /// 1115B.4.1 item WC Seat Is the top of the WC seat between 17 and 19 AFF? /// 1115B.4.1 item WC Flush Controls Are flush controls automatic operable with one hand and located on the wide side of the WC where the clear flo space is provided? /// 1115B.4.1 item /4 wide Depth ok. The length of the stall is long enough to accommodate the 56 clear compartment space; however there is a 6 stile installed on the hinge side of the compartment do which reduces the required compartment depth to 54. See photo and sketch below. Reconfigure compartment by lengthening the partition adjacent to the toilet to achieve 56 minimum clear from the rear wall. Reduce stile size at the hinge side of compartment do /2 at front 18-1/4 at back Can toilet be adjusted? 18-1/2 Page 4 of 8

103 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : Toilet Paper Dispenser Is the toilet paper dispenser located a minimum of 7 and a maximum of 9 in front of the water closet measured to the centerline of the dispenser; mounted below the grab bar, with the outlet of the dispenser at a minimum height of 19 AFF? /// 1115B from back wall. Bottom roll: 20-1/2 AFF Top roll: 28-1/2 AFF Toilet Paper Dispenser Toilet Paper Dispenser Seat Cover Dispenser **1991 Standards and CBC allowed dispenser to be located within 12 of the front edge of the toilet seat, and 36 maximum to the far edge from the rear wall. See Safe Harb Provisions. Is the toilet paper dispenser mounted below the side grab bar? /// 1115B.8.4 Does the toilet paper dispenser allow continuous paper delivery? /// 1115B.8.4 Is the highest operable part of the seat cover dispenser no higher than 40 inches AFF? /// 1115B Grab Bars Is there a 42 side grab bar and a 36 rear grab bar in the stall, centered at 33 AFF? (The rear grab bar may be centered at 36 AFF at tank-type toilets.) 604.5, 609.4, /// 1115B.4.1 items 3.1 & 3.2, Fig. 11B-1A Grab Bar Diameter Grab Bar Wall Clearance Grab Bar Clearance Is the outside diameter of the grab bar between 1-1/4 and 1-1/2? /// 1115B.7.1 Is the space between the grab bar and the wall exactly 1-1/2 inches? /// 1115B.7.1 Is any dispenser located so that it does not obstruct the use of the grab bar (e.g., no closer than 12 above and 1-1/2 below the tangent point of the grab bar unless dispenser is recess, flush with wall and has no sharp edges)? /// 40 **1991 Standards allowed a 19 above and 2 below See Safe Harb provisions Hazards at Are grab bars and adjacent walls free of sharp Grab Bars abrasive elements? /// 1115B Side Grab Bar Does the side grab bar extend at least 54 min beyond the rear wall while the other end is a maximum of 12 from the rear wall, with the front end positioned 24 min. in front of the WC? /// 1115B.4.1 item from rear wall. Relocate 42 grab bar so it is a maximum of 12 from the rear wall and extends a minimum of 54 from the rear wall. Install at 33 o.c. AFF. Page 5 of 8

104 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : Rear Grab Bar Does the rear grab bar extend from the centerline of the WC 12 min. on one side and 24 min. on the other side? /// 1115B.4.1 item Semi- Ambulant Stall Semi- Ambulant Stall Where 6 me toilet stalls are provided, in addition to the 60 wide accessible stall, is at least one semiambulant stall 36 wide with an outward swinging, self-closing do provided? /// 1115B.3.1 item 5 Are there two side grab bars in the semi-ambulant stall, 42 in length, and located 12 maximum from the rear wall? /// 1115B.3.1 item 5, 1115B.4.1 item Urinals Where urinals are provided, does at least one comply with the requirements below? /// 1115B Urinal Rim Height Clear at Urinal Width Between Screens at Urinal Width Between Screens at Urinal Does the urinal have an elongated rim projecting at least 14 from the wall and a maximum of 17 AFF? /// 1115B.4.2 item 1 Is there a clear flo space at least 30 x 48 which allows a fward approach to the urinal? /// 1115B.4.2 item 3 If urinal screens are provided and they extend less than 24 beyond the front edge of the urinal rim, is there at least 30 between the two panels? /// 1115B.4.2 item 3 If urinal screens are provided and they do extend me than 24 beyond the front edge of the urinal rim, is there at least 36 between the two panels? 605.3, /// 1118B.4 item 2, Fig. 11B-5A(b) Lavaties If lavaties are provided, does at least one lavaty meet the requirements below? /// 1115B Lavaty Rim Height Lavaty Apron Clearance Lavaty Knee Clearance Lavaty Wall ion Clear at Lavaty Side Clearance at Lavaty Is the lavaty rim counter surface no higher than 34 AFF? /// 1115B.4.3 item 2 Is there at least 29 clearance from the flo to the bottom of the apron? /// 1115B.4.3 item 2 Is there at least 27 clearance from the flo to the underside of the lavaty, extending 8 minimum measured from the front edge underneath the lavaty back towards the wall? /// 1115B.4.3 item 2, Fig 11B-1D Does the front edge of the lavaty project at least 17 from the wall? /// 1115B.4.3 item 2 Is there a clear flo space at least 30 x 48 in front of the lavaty (extending a maximum of 19 underneath the lavaty) allowing a fward approach? /// 1115B.4.3 item 3 Is there a minimum of 18 from the centerline of the lavaty to the nearest sidewall partition? /// 1115B.4.3 item /2 35-1/2 29-1/4 Page 6 of 8

105 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : Lavaty Location Pipe Insulation at Lavaty Smooth Surfaces at Lavaty Faucet Operation at Lavaty Faucet Operation at Lavaty Does the clear flo space adjoin overlap an accessible route of travel (is there at least 48 clearance between the front edge of the lavaty and the nearest obstruction)? /// 1115B.4.3 item 3 Are drainpipes and hot water pipes insulated to protect against contact? /// 1115B.4.3 item 4 Is the area below the lavaty free of sharp abrasive surfaces? /// 1115B.4.3 item 4 Can the faucet be operated with one hand without tight grasping, pinching, twisting of the wrist? /// 1115B.4.3 item 1 If the valve is self-closing, does it remain open f at least 10 seconds? /// 1115B.4.3 item Mirrs Where mirrs are provided, does at least one mirr have the bottom edge of the reflecting surface no higher than 40 AFF? /// 1115B Coat Hook Where a coat hook is provided in an accessible stall is it 48 maximum AFF? /// 1117B Dispensers Operating Height at Dispensers Dispenser Operation Is at least one of each dispenser type accessible and is the highest operable part no higher than 40 AFF? (Indicate type, e.g., paper towel dispenser [PTD], electrical dryer [ED], soap dispenser [SD], and height in inches.) /// 1115B.8.3 Is there a clear flo space at least 30 x 48 in front of the dispenser allowing either a fward a parallel approach to the dispenser? /// 1117B.6 item 2 Can the dispenser be operated with one hand without tight grasping, pinching, twisting of the wrist? 309 /// 1117B.6 item Alarm In buildings where an emergency warning system is required, is there a visual alarm (strobe) in the toilet room? 215 /// , , 1114B.2.2 Paper towel at 41 AFF Provide paper towel dispenser with operable part no higher than Other slope is good. NOTES: Page 7 of 8

106 TOILET FACLITIES Survey Fm 16 /Room 28 Liberty Ship Way Name: Men s Restroom 2nd : TR4 : 2nd : Code Clearance Typical f Men s and Women s accessible stall both flos. Page 8 of 8

107 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Women s Shower 1 st TR1 : Shower : 1st : x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Grab Bar Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side /// 1115B Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? /// 1115B Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? /// 1115B Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? /// 1115B Is the surface slope at 2% less in any direction? /// 1115B Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? ///1115B Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, /// 1115B When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B Does the folding seat extend the full-required depth of the stall? /// 1115B , Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? /// 1115B , Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? /// 1115B , Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? /// 1115B , Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? /// 1115B , 1115B.7.2 Are grab bars located on walls adjacent to and opposite the seat? /// 1115B , Fig. 11A, 11B As-built Dimensions 35-7/8 x 61-3/4 Entry width at 35-3/16 2.5% Seat mounted at 17-3/4 above flo. Clearances to wall OK. 14-9/ /2 Page 1 of 3

108 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Women s Shower 1 st TR1 : Shower : 1st : Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) /// 1115B Are grab bars mounted between above flo surface? /// 1115B Are grab bars between 1 ¼ 1 ½ diameter equivalent? /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? /// 1115B thru.4 Are the grab bars stable and do not rotate within their fittings? /// 1115B Is the water valve control a single lever type? /// 1115B Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? , /// 1115B Is the fce to operate the controls a maximum of 5lbs? /// 1115B Is the centerline of the control valves between 39 to 41 above the shower flo? , /// 1115B Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? /// 1115B Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? /// 1115B Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? , /// 1115B As-built Dimensions /2 Control Valve at 24 Diverter Valve at 14-1/8 Diverter valve should be located with-in the control area of from the rear edge of the seat. 40-1/2 Page 2 of 3

109 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Women s Shower 1 st TR1 : Shower : 1st : Design Design Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? As-built Dimensions No soap dish /// 1115B.8.5, 1115B.2 Other Hooks at 51-1/2 and 57 AFF Do not meet required reach ranges no higher than 48. Lower add hook at a height not greater than 48. NOTES: Page 3 of 3

110 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Men s Shower 1 st TR2 : Shower : 1st : x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Grab Bar Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side /// 1115B Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? /// 1115B Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? /// 1115B Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? /// 1115B Is the surface slope at 2% less in any direction? /// 1115B Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? ///1115B Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, /// 1115B When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B Does the folding seat extend the full-required depth of the stall? /// 1115B , Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? /// 1115B , Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? /// 1115B , Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? /// 1115B , Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? /// 1115B , 1115B.7.2 Are grab bars located on walls adjacent to and opposite the seat? /// 1115B , Fig. 11A, 11B As-built Dimensions 36 x 62-1/4 Entry width at 35-1/2 2.2% Seat mounted at 18 above flo. Clearances to wall OK. 5-1/ /2 16 Page 1 of 3

111 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Men s Shower 1 st TR2 : Shower : 1st : Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) /// 1115B Are grab bars mounted between above flo surface? /// 1115B Are grab bars between 1 ¼ 1 ½ diameter equivalent? /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? /// 1115B thru.4 Are the grab bars stable and do not rotate within their fittings? /// 1115B Is the water valve control a single lever type? /// 1115B Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? , /// 1115B Is the fce to operate the controls a maximum of 5lbs? /// 1115B Is the centerline of the control valves between 39 to 41 above the shower flo? , /// 1115B Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? /// 1115B Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? /// 1115B Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? , /// 1115B As-built Dimensions 33 Control Valve at 23-1/2 Diverter Valve at 14 +/- Diverter valve should be located with-in the control area of from the rear edge of the seat. 40-1/4 Page 2 of 3

112 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Men s Shower 1 st TR2 : Shower : 1st : Design Design Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? As-built Dimensions No soap dish /// 1115B.8.5, 1115B.2 Other Hooks at 51 and 57 AFF Do not meet required reach ranges no higher than 48. Lower add hook at a height not greater than 48. NOTES: Page 3 of 3

113 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Women s Shower 2nd TR3 : Shower : 2nd : x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Grab Bar Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side /// 1115B Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? /// 1115B Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? /// 1115B Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? /// 1115B Is the surface slope at 2% less in any direction? /// 1115B Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? ///1115B Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, /// 1115B When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B Does the folding seat extend the full-required depth of the stall? /// 1115B , Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? /// 1115B , Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? /// 1115B , Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? /// 1115B , Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? /// 1115B , 1115B.7.2 Are grab bars located on walls adjacent to and opposite the seat? /// 1115B , Fig. 11A, 11B As-built Dimensions 35-5/16 x 59-5/8 Entry width at 35-5/8 2.7% Seat mounted at 18-1/2 above flo. Clearances to wall OK. 22-1/2 Page 1 of 3

114 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Women s Shower 2nd TR3 : Shower : 2nd : Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) /// 1115B Are grab bars mounted between above flo surface? /// 1115B Are grab bars between 1 ¼ 1 ½ diameter equivalent? /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? /// 1115B thru.4 Are the grab bars stable and do not rotate within their fittings? /// 1115B Is the water valve control a single lever type? /// 1115B Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? , /// 1115B Is the fce to operate the controls a maximum of 5lbs? /// 1115B Is the centerline of the control valves between 39 to 41 above the shower flo? , /// 1115B Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? /// 1115B Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? /// 1115B Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? , /// 1115B As-built Dimensions Control Valve at 24 Diverter Valve at 14-1/4 Diverter valve should be located with-in the control area of from the rear edge of the seat. 41 Page 2 of 3

115 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Women s Shower 2nd TR3 : Shower : 2nd : Design Design Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? As-built Dimensions No soap dish /// 1115B.8.5, 1115B.2 Other Hooks at 51-1/2 and 57 AFF Do not meet required reach ranges no higher than 48. Lower add hook at a height not greater than 48. NOTES: Page 3 of 3

116 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Men s Shower 2nd TR4 : Shower : 2nd : x 60 Shower Stall Design 30 x 60 Shower Stall Design Alternate Roll-In Shower Stall Design Alternate Roll-In Shower Stall Design Design Design Seating Seating Seating Seating Seating Seating Seating Grab Bar Is the roll-in shower a minimum 60 in width between wall surfaces and a minimum 30 in depth with a full opening width on the long side /// 1115B Is the clear flo space that adjoins the shower compartment a minimum of 36 x 60? /// 1115B Is the roll-in shower a minimum 36 x 60 with a minimum entry width of 36? /// 1115B Is there a minimum 36 wide clear flo space adjoining the shower seat to allow f parallel transfer? /// 1115B Is the surface slope at 2% less in any direction? /// 1115B Where drains are provided, are the grate openings minimum of ¼ and located flush with the flo surface? ///1115B Is there a folding seat mounted 18 above flo? Is the clearance from the seat to the adjacent wall surfaces minimum of 1 and a maximum of 1 ½? 608.4, /// 1115B When folded, does the shower seat extend a maximum 6 from the mounting (back) wall? ///1115B Does the folding seat extend the full-required depth of the stall? /// 1115B , Fig. 11B-2D Does the wide ption of the seat extend a maximum of 15 from the adjacent wall? /// 1115B , Fig. 11B-2D Does the wide ption of the seat extend a maximum of 23 from the mounting (back) wall? /// 1115B , Fig. 11B-2D Does the narrow ption of the seat extend a maximum of 16 from the mounting (back) wall? /// 1115B , Fig. 11B-2D Does the shower seat provide a minimum Structural strength to suppt a 250 lb point load? /// 1115B , 1115B.7.2 Are grab bars located on walls adjacent to and opposite the seat? /// 1115B , Fig. 11A, 11B As-built Dimensions 35-1/4 x 58-7/8 Entry width at 35-7/16 Slopes OK Seat mounted at 18 above flo. Clearances to wall OK. 5-1/2 14-3/4 22-1/2 16 Page 1 of 3

117 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Men s Shower 2nd TR4 : Shower : 2nd : Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Grab Bar Design Controls Controls Controls Controls Controls Controls Is grab bar L-shaped and continuous along the wall opposite from and adjacent to the seat? (But NOT extended to include the ption of wall over the seat) /// 1115B Are grab bars mounted between above flo surface? /// 1115B Are grab bars between 1 ¼ 1 ½ diameter equivalent? /// 1115B.7.1 Is the clearance between the wall and grab bar 1 ½? /// 1115B.7.1 Are the bars smooth with a minimum radius of 1/8? /// 1115B.4.1.3, 1115B.7.3 Do the bars provide a minimum structural strength to suppt a 250lb point load? /// 1115B thru.4 Are the grab bars stable and do not rotate within their fittings? /// 1115B Is the water valve control a single lever type? /// 1115B Is the centerline of the control located on the side wall of the compartment adjacent to the seat within reach range of no less than 19 and no me than 24 from the rear edge of the seat? , /// 1115B Is the fce to operate the controls a maximum of 5lbs? /// 1115B Is the centerline of the control valves between 39 to 41 above the shower flo? , /// 1115B Are the controls operable with one hand and do not require tight grasping, pinching twisting of the wrist? /// 1115B Is a flexible hand held spray unit with a hose at least 60 long that can be used both as a fixed shower head and as a hand-held shower provided and mounted such that the top of the mounting bracket is at a maximum height of 48 from the flo? /// 1115B Is the hand-held sprayer unit located on the back wall of the compartment adjacent to the seat, and the centerline of the control is no me than 27 from the seat wall? , /// 1115B As-built Dimensions 33-1/4 Control Valve at 23-1/4 Diverter Valve at 14 +/- Diverter valve should be located with-in the control area of from the rear edge of the seat /2 from flo 10 from wall Page 2 of 3

118 SHOWER FACILITY Survey Fm 17 /Room 28 Liberty Ship Way Name: Men s Shower 2nd TR4 : Shower : 2nd : Design Design Is the soap dish mounted on the control wall at 40 maximum height and within reach limits from the seat? /// 1115B Where lockers are provided f the public, clients, employees, members, participants, is at least one and not less than 5% of all lockers accessible. Is a path of travel not less than 36 in clear width provided to these lockers? As-built Dimensions No soap dish /// 1115B.8.5, 1115B.2 Other Hooks at 51 and 57 AFF Do not meet required reach ranges no higher than 48. Lower add hook at a height not greater than 48. NOTES: Page 3 of 3

119 EXHIBIT 1-28 LIBERTY SHIP WAY SITE PLAN PK1 WALKING TRAIL BUS STOP

ACCESSIBILITY REVIEW

ACCESSIBILITY REVIEW Swinerton Builders CA Lic. N o 92 15 Business Park Way, Suite 101 Sacramento, CA 95828 Tel: 916.383.4825 Fax: 916.383.6014 www.swinerton.com INTEGRITY LEADERSHIP PASSION EXCELLENCE ACCESSIBILITY REVIEW

More information

Accessible Routes. Chapter 1. Accessible Routes & Clearances. General Notes

Accessible Routes. Chapter 1. Accessible Routes & Clearances. General Notes Chapter 1 Accessible Routes Accessible Routes & Clearances Accessible routes or paths of travel in new and existing projects are essential aspects of Accessible design. If you cannot even get to an area,

More information

ADA Checklist RESTAURANTS AND CAFETERIAS

ADA Checklist RESTAURANTS AND CAFETERIAS ADA Checklist RESTAURANTS AND CAFETERIAS 205 North 400 West Salt Lake City, Utah 84103 (800) 662 9080 (800) 550 4182 TTY www.disabilitylawcenter.org Restaurant Name Getting into the Restaurant Parking

More information

The Moscone Center Facility Accessibility Information

The Moscone Center Facility Accessibility Information The Moscone Center Facility Accessibility Information Introduction It is The Moscone Center s intention to provide all reasonable accommodation for persons with disabilities to assist them in attending

More information

NAU DESIGN GUIDELINES FOR DISABLED ACCESS PARKING AND ACCESSIBLE ROUTE AT VEHICULAR TRAFFIC AREAS

NAU DESIGN GUIDELINES FOR DISABLED ACCESS PARKING AND ACCESSIBLE ROUTE AT VEHICULAR TRAFFIC AREAS NAU DESIGN GUIDELINES FOR DISABLED ACCESS PARKING AND ACCESSIBLE ROUTE AT Intent, Purpose And Goals: The intent and purpose of these NAU technical requirements is to establish minimum requirements to safeguard

More information

Chapter 5. General Site and Building Elements

Chapter 5. General Site and Building Elements 501 General Chapter 5. General Site and Building Elements 501.1 Scope. General site and building elements required to be accessible by the scoping provisions adopted by the administrative authority shall

More information

Public Health Services San Joaquin Co.

Public Health Services San Joaquin Co. Proposed San Joaquin Co. Stockton, California REVISIONS No. Description Cover Sheet Data CS No. Description Site Plan A1 No. Description Enlarged Existing Lab Area Site / Demolition Plan A2 No. Description

More information

FORM A: ACCESSIBILITY CHECKLIST. Questions. Possible Solutions A. PARKING. Location Name Location Address: (street address) (city) (state) (zip)

FORM A: ACCESSIBILITY CHECKLIST. Questions. Possible Solutions A. PARKING. Location Name Location Address: (street address) (city) (state) (zip) FORM A: ACCESSIBILITY CHECKLIST Survey Date: Location Name Location Address: (street address) (city) (state) (zip) Questions A. PARKING 1) Does the facility have: a) accessible parking spaces available?

More information

ACCESSIBILITY SELF-EVALUATION CHECKLIST

ACCESSIBILITY SELF-EVALUATION CHECKLIST ACCESSIBILITY SELF-EVALUATION CHECKLIST Section 504 of the Rehabilitation Act of 1973 Date: County: Region: County Program Director: Please check either yes, no, or not applicable (N/A) to each question.

More information

ACCESSIBILITY DETAILS FOR PARKING

ACCESSIBILITY DETAILS FOR PARKING INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Sec.11B-208,11B-228.3,11B-502, Effective: 01/01/2017 11B-812,1113A,1138A DOCUMENT NO.: P/BC 2017-084 Revised: 10/18/2017 Previously Issued

More information

CHAPTER 4: ACCESSIBLE ROUTES

CHAPTER 4: ACCESSIBLE ROUTES CHAPTER 4: ACCESSIBLE ROUTES 401 General 401.1 Scope. The provisions of Chapter 4 shall apply where required by Chapter 2 or where referenced by a requirement in this document. 402 Accessible Routes 402.1

More information

Surveyor Information

Surveyor Information Surveyor Information Name of Firm Permit Solutions, Inc. Name of Surveyor Mike Russell Contact Number 847--550 Contact Email mrussell@permitsolutionsohio.com Date of Survey November, 07 Pre-Construction

More information

ADA Became Law In 1990

ADA Became Law In 1990 ADA Became Law In 1990 Many conflicts between State & Federal guidelines exist. Always default to the more stringent requirements. California Access Codes have come closer but still not equal to the Federal

More information

(2) For mounting heights suitable in schools and other facilities used primarily by children see section

(2) For mounting heights suitable in schools and other facilities used primarily by children see section Last page revision- March 31st, 1999 TEXAS ACCESSIBILITY STANDARDS (TAS) TAS Table of Contents 4.10 Elevators. 4.10.1 General. (1) Accessible elevators shall be on an accessible route and shall comply

More information

th Edition Florida Accessibility Code for Building Construction

th Edition Florida Accessibility Code for Building Construction 2014 5 th Edition Florida Accessibility Code for Building Construction Course Title: 2014 Florida Building Code Advanced Accessibility ADOPTED PURSUANT TO SECTION 553.503, FLORIDA STATUTES BASED ON THE

More information

Shelter: Primary Shelter Secondary Shelter Respite Site Only Client Service Center Pet Shelter

Shelter: Primary Shelter Secondary Shelter Respite Site Only Client Service Center Pet Shelter DIRECTIONS: Print legibly. Complete all sections as thoroughly as possible, indicating numbers, space dimensions, etc. Record only usable space. If a room is 600 square feet, but has furniture or fixtures

More information

GOVERNOR S OFFICE of PLANNING AND RESEARCH

GOVERNOR S OFFICE of PLANNING AND RESEARCH STATE OF CALIFORNIA GOVERNOR S OFFICE of PLANNING AND RESEARCH EDMUND G. BROWN JR. GOVERNOR KEN ALEX DIRECTOR Plug-In Electric Vehicles: Universal Charging Access Guidelines and Best Practices These draft

More information

Chapter 8 - Special Rooms and Spaces

Chapter 8 - Special Rooms and Spaces Chapter 8 - Special Rooms and Spaces 801 General 801.1 Scope. Special rooms and spaces required to be accessible by the scoping provisions adopted by the administrative authority shall comply with the

More information

Georgia-Pacific Compliance Guide for Title III of the Americans with Disabilities Act

Georgia-Pacific Compliance Guide for Title III of the Americans with Disabilities Act Georgia-Pacific Compliance Guide for Title III of the Americans with Disabilities Act Enacted in 1990, the Americans with Disabilities Act (ADA) is a federal civil rights law granting equal rights and

More information

Location: Fraser Fort George, Prince George, Northern BC - Municipal : Trail (Great Northern Circle Route)

Location: Fraser Fort George, Prince George, Northern BC - Municipal : Trail (Great Northern Circle Route) Mt Robson Visitors Centre Information Date of Audit: 2016-10-20 Park Name: Fergusen Lake Key Features: Picnic_Site,Trails Location: Fraser Fort George, Prince George, Northern BC - Municipal : Trail (Great

More information

ADA Entrance Accessibility

ADA Entrance Accessibility ADA Entrance Accessibility Objective 1 - Latch requirements for an opening Objective 2 - Characteristics of a clear opening Objective 3 - Opening force requirements for an opening Objective 4 - Closing

More information

Purpose: General Provisions:

Purpose: General Provisions: 10-19-1 Purpose: The purpose of off-street parking requirements is to promote traffic/pedestrian safety and efficiency and to minimize hard surfaced areas to reduce storm water run-off and visual impacts

More information

CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES

CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES 601 General 601.1 Scope. The provisions of Chapter 6 shall apply where required by Chapter 2 or where referenced by a requirement in this document. 602 Drinking

More information

CITY OF LEMOORE AMERICAN WITH DISABILITIES ACT TRANSITION PLAN FINAL

CITY OF LEMOORE AMERICAN WITH DISABILITIES ACT TRANSITION PLAN FINAL CITY OF LEMOORE AMERICAN WITH DISABILITIES ACT TRANSITION PLAN FINAL Approved 9/3/13 September 3, 2013 1.0 Introduction 1.1 Summary The American with Disabilities Act (ADA) is a comprehensive civil rights

More information

Designing Pedestrian Facilities for Accessibility. Module 7 Street Furniture and On-Street Parking

Designing Pedestrian Facilities for Accessibility. Module 7 Street Furniture and On-Street Parking Module 7 Furniture and On- R212 Furniture (R307) On- Benches Drinking Fountains Meters lights Utility poles/hardware Transit shelters Bike racks Newspaper vending Public Telephones Sculptures The Zone

More information

REAR +/- 94' 20' 10' 10'-4" 9'-6" 10'-3" 10' 20' 13'-2" Private Office 25. Private Office 23 Private Office 24 7'-1" Open Space 3 14'-7"

REAR +/- 94' 20' 10' 10'-4 9'-6 10'-3 10' 20' 13'-2 Private Office 25. Private Office 23 Private Office 24 7'-1 Open Space 3 14'-7 REAR +/- 94' 20' 10' 10'-4" 9'-6" 10'-3" 10' 20' 2801 Finley Road Unit A 1975 W. Happy Trails Happy, CA 55555 Shared Office 4 15'-5" 13'-2" 12' 12' Private Office 23 Private Office 24 Private Office 25

More information

ACCESSIBILITY. for Public Charging Stations. Plug-In Electric Vehicle Planning Toolbox

ACCESSIBILITY. for Public Charging Stations. Plug-In Electric Vehicle Planning Toolbox Version 2.0 (November 2014) for Public Charging Stations Governing Standards As municipalities and businesses install publically available plug-in electric vehicle (PEV) charging stations, an important

More information

ZONING CODE PARKING REGULATIONS

ZONING CODE PARKING REGULATIONS CHAPTER 169 ZONING CODE PARKING REGULATIONS 169.01 Purpose 169.06 Design For Parking Facilities 169.02 Authority and Application 169.07 Stacking Spaces For Drive-Through Facilities 169.03 Off-Street Loading

More information

APPENDIX B TRAINING MANUAL

APPENDIX B TRAINING MANUAL APPENDIX B TRAINING MANUAL BUS STOP ADA ASSESSMENT STUDY Assessment Procedures and Practices Training and Guidance Manual OVERVIEW Space Coast Area Transit wishes to improve the accessibility, safety,

More information

Temporary Sales Trailer Application

Temporary Sales Trailer Application Development Services Department Building Division 311 Vernon Street Roseville, California 95678-2649 Temporary Sales Trailer Application General: Requests for temporary sales trailers, which comply with

More information

ARTICLE 8 OFF-STREET PARKING AND PRIVATE DRIVEWAY STANDARDS

ARTICLE 8 OFF-STREET PARKING AND PRIVATE DRIVEWAY STANDARDS ARTICLE 8 OFF-STREET PARKING AND PRIVATE DRIVEWAY STANDARDS TABLE OF CONTENTS SECTION PAGE 8.1 GENERAL STANDARDS...8-2 8.2 PRIVATE DRIVEWAY PROVISIONS...8-4 8.3 OFF-STREET PARKING STANDARDS...8-5 8.4 OFF-STREET

More information

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 5 GROUP B AND GROUP M OCCUPANCIES

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 5 GROUP B AND GROUP M OCCUPANCIES AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES Plan Check No. 1. Electronic information processing devices that accept or dispense cash in connection with a credit, deposit or convenience

More information

ACCESSIBILITY GUIDE REVISED

ACCESSIBILITY GUIDE REVISED ACCESSIBILITY GUIDE REVISED 2017-09-28 Oregon Convention Center Facility Accessibility Information It is the Oregon Convention Center s intention to provide all reasonable accommodation for persons with

More information

Chapter 6. Plumbing Elements and Facilities

Chapter 6. Plumbing Elements and Facilities AMERICAN NATIONAL STANDARD Chapter 6. Plumbing Elements and Facilities Chapter 6. Plumbing Elements and Facilities 601 General 601.1 Scope. Plumbing elements and facilities required to be accessible by

More information

Accessibility Survey Techniques. John Salmen, AIA Andrew Yarrish, AIA Universal Designers & Consultants, Inc.

Accessibility Survey Techniques. John Salmen, AIA Andrew Yarrish, AIA Universal Designers & Consultants, Inc. John Salmen, AIA Andrew Yarrish, AIA www. Outline of Program 1. Tools 2. Accessibility Checklists 3. Measurement Questions will be taken throughout 2 1 Objectives Become familiar with measuring techniques

More information

APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE MARKHAM CAMPUS MARKHAM, ONTARIO

APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE MARKHAM CAMPUS MARKHAM, ONTARIO APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE MARKHAM CAMPUS MARKHAM, ONTARIO Prepared by: Rita Cherniavskaya & Elias Frechette Technical Consultants

More information

ACCESSIBLE COMMUNITY BUILDER CHECKLIST

ACCESSIBLE COMMUNITY BUILDER CHECKLIST ACCESSIBLE COMMUNITY BUILDER CHECKLIST Multifamily Residential Commercial Industrial Institutional NOTE: The City of Parksville has adopted this checklist as an informal guide to assist developers in considering

More information

DIVISION 6: PLUMBING ELEMENTS AND FACILITIES

DIVISION 6: PLUMBING ELEMENTS AND FACILITIES DIVISION 6: PLUMBING ELEMENTS AND FACILITIES 11B-601 General 11B-601.1 Scope. The provisions of Division 6 shall apply where required by Division 2 or where referenced by a requirement in this chapter.

More information

County of Fresno. South Annex Jail ADA Transition Plan LARS ANDERSEN & ASSOCIATES, INC. Prepared by:

County of Fresno. South Annex Jail ADA Transition Plan LARS ANDERSEN & ASSOCIATES, INC. Prepared by: County of Fresno South Annex Jail ADA Transition Plan Prepared by: LARS ANDERSEN & ASSOCIATES, INC. CIVIL ENGINEERS LAND SURVEYORS PLANNERS LEED ACCREDITED ACCESS COMPLIANCE STORM WATER QUALITY 4694 W

More information

Access California. New Regulations for Electric Vehicle Charging Stations. presented to The City of Palo Alto, California

Access California. New Regulations for Electric Vehicle Charging Stations. presented to The City of Palo Alto, California New Regulations for presented to The City of Palo Alto, California Dennis J. Corelis Deputy State Architect, Access Code and Policy 18 November 2016 Copyright Electric Vehicles Are Here! Expansion of EV

More information

Oregon Conventi Center

Oregon Conventi Center Oregon Conventi on Center Accessi bi l i tygui de Revi sedmay2014 Oregon Convention Center Facility Accessibility Information It is the Oregon Convention Center s intention to provide all reasonable accommodation

More information

ANN ARBOR CITY NOTICE ORDINANCE NO. ORD OFF STREET PARKING CHAPTER 59

ANN ARBOR CITY NOTICE ORDINANCE NO. ORD OFF STREET PARKING CHAPTER 59 ANN ARBOR CITY NOTICE ORDINANCE NO. ORD-12-04 OFF STREET PARKING CHAPTER 59 AN ORDINANCE TO AMEND SECTIONS 5:168 AND 5:169 OF CHAPTER 59 (OFF- STREET PARKING) OF TITLE V OF THE CODE OF THE CITY OF ANN

More information

Amusement Rides. ADA Checklist for Existing Facilities. Amusement rides should be accessible to everyone, including people with disabilities.

Amusement Rides. ADA Checklist for Existing Facilities. Amusement rides should be accessible to everyone, including people with disabilities. Project Building Location Date Surveyors Contact Information Amusement rides should be accessible to everyone, including people with disabilities. Institute for Human Centered Design www.humancentereddesign.org

More information

CHAPTER 90. STREETS, SIDEWALKS AND PUBLIC WAYS ARTICLE II. USE OF STREETS, SIDEWALKS AND PUBLIC WAYS DIVISION 10. SIDEWALK CAFÉS

CHAPTER 90. STREETS, SIDEWALKS AND PUBLIC WAYS ARTICLE II. USE OF STREETS, SIDEWALKS AND PUBLIC WAYS DIVISION 10. SIDEWALK CAFÉS CHAPTER 90. STREETS, SIDEWALKS AND PUBLIC WAYS ARTICLE II. USE OF STREETS, SIDEWALKS AND PUBLIC WAYS DIVISION 10. SIDEWALK CAFÉS Sec. 90-271. Definitions. The following words, terms and phrases, when used

More information

Article 6: Off Street Parking and Loading Standards. Table of Contents. page

Article 6: Off Street Parking and Loading Standards. Table of Contents. page Article 6: Off Street Parking and Loading Standards Table of Contents page Sec. 601 Purpose of Article 6.... 6-1 Sec. 602 Off-street parking; when required.... 6-1 Sec. 603 Number of parking spaces required....

More information

Parking and Loading. Page 1 of 7

Parking and Loading. Page 1 of 7 Parking and Loading 21.03.020 Off-street parking and loading. A. Purpose. The purpose of this section is to ensure that sufficient off-street parking and loading areas are provided and properly designed

More information

Electric Vehicle Charging System Guidelines for Residential Buildings

Electric Vehicle Charging System Guidelines for Residential Buildings Check One Electric Vehicle Charging System Guidelines for Residential Buildings Checklist Review for Residential Electric Vehicle Charging Station Permits Type of Charging Station(s) Proposed CITY OF CYPRESS

More information

Also below is a limited list of the proposals which will be included in the first draft of the revised ICC/ANSI A117.1 standard for accessibility.

Also below is a limited list of the proposals which will be included in the first draft of the revised ICC/ANSI A117.1 standard for accessibility. TO: DATE: Code Task Force Chair CC: Randy Smith, Regal Cinemas FROM: Gene Boecker, AIA Todd Halstead, NATO RE: NATIONAL ASSOCIATION OF THEATRE OWNERS 2013-2014 ICC PROPOSED CODE CHANGES- IFC & IEBC ICC/ANSI

More information

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD EMERGENCY APPARATUS ACCESS WAYS STANDARD #B-003 EFFECTIVE 05-05-2009 PURPOSE To establish a consistent guideline for fire access roadways required by

More information

CHAPTER 2 ZONING AND DEVELOPMENT

CHAPTER 2 ZONING AND DEVELOPMENT 2.200 GENERAL DEVELOPMENT STANDARDS CHAPTER 2 ZONING AND DEVELOPMENT Section 2.201 GENERAL PROVISIONS... 2.2-1 Section 2.202 FENCES AND VISIONS CLEARANCE... 2.2-2 2.202.01 Fences... 2.2-2 2.202.02 Vision

More information

Table Station Elements

Table Station Elements The overall layout of the station in the Preferred Alternative (Modified Alternative 2) is described in Table 7.5-1. Table 7.5-1 Station Elements Ground Level Mezzanine Level Platform Level Existing/Upgraded

More information

ORDINANCE NO

ORDINANCE NO ORDINANCE NO. 07-5424 AN ORDINANCE OF THE CITY OF BILLINGS, PROVIDING THAT THE BILLINGS, MONTANA CITY CODE BE AMENDED BY REVISING SECTION 6-1208; PROVIDING CHANGES TO CERTAIN CURB CUT LENGTHS AND REGULATIONS.

More information

Appendix D: ADA Self- Assessment

Appendix D: ADA Self- Assessment Appendi D: ADA Self- Assessment 2014 Palmer Open Space and Recreation Plan Page 232 ADA Transition Plan Facility Name Jurisdiction Location Endelson Playground Recreation Department & Parks Department

More information

800 Access Control, R/W Use Permits and Drive Design

800 Access Control, R/W Use Permits and Drive Design Table of Contents 801 Access Control... 8-1 801.1 Access Control Directives... 8-1 801.2 Access Control Policies... 8-1 801.2.1 Interstate Limited Access... 8-1 801.2.2 Limited Access... 8-1 801.2.3 Controlled

More information

Capital Programs Institute Provider Number: I Accessibility Training Course Number: CLA-AT-0917

Capital Programs Institute Provider Number: I Accessibility Training Course Number: CLA-AT-0917 Capital Programs Institute Provider Number: I005 2017 Accessibility Training Course Number: CLA-AT-0917 Susan Moe, CASp Senior Architect Division of State Architect Sacramento ICC Accessibility Inspector/Plans

More information

6.16 OFF-STREET PARKING AND LOADING REQUIREMENTS

6.16 OFF-STREET PARKING AND LOADING REQUIREMENTS 6.16 OFF-STREET PARKING AND LOADING REQUIREMENTS 6.16.1 Off-Street Parking Off-street parking and loading spaces shall be required for all land uses as set forth in this section. A. Minimum Parking Space

More information

ADA Design Guide Washrooms & Showers

ADA Design Guide Washrooms & Showers ADA Design Guide Washrooms & Showers Accessories Faucets Showers Toilets Lavatories interactive version available at bradleycorp.com/adaguide.pdf Accessible Stall Design There are many dimensions to consider

More information

THE CORPORATION OF THE TOWNSHIP OF MIDDLESEX CENTRE BY-LAW NUMBER

THE CORPORATION OF THE TOWNSHIP OF MIDDLESEX CENTRE BY-LAW NUMBER THE CORPORATION OF THE TOWNSHIP OF MIDDLESEX CENTRE BY-LAW NUMBER 2006-052 BEING A BY-LAW TO REGULATE AND CONTROL PARKING WITHIN THE TOWNSHIP OF MIDDLESEX CENTRE WHEREAS the Municipal Act authorizes local

More information

(New), (New)

(New), (New) 4-1 12 402 (New), 402.1 (New) Proponent: Kim Paarlberg, International Code Council 402 Accessible means of egress 402.1 General. Means of egress shall comply with Section 1007 of the International Building

More information

Plan Check Policies and Guidelines

Plan Check Policies and Guidelines VIII. TRAFFIC SIGNING AND STRIPING PLANS A. INTRODUCTION Traffic signing and striping plans are required for all General Plan Roads and any roadway that is 56-foot wide curb-to-curb (78 R/W) or wider.

More information

OFF-STREET PARKING. A. Parking facilities for each use shall be provided in accord with the minimum requirements set forth in Table 9-1.

OFF-STREET PARKING. A. Parking facilities for each use shall be provided in accord with the minimum requirements set forth in Table 9-1. 09 ARTICLE NINE OFF-STREET PARKING 9-1 Purpose The off-street parking regulations require that developments provide parking in proportion to the need created by each use. The regulations further establish

More information

MOTOR VEHICLE ORIENTED BUSINESSES.

MOTOR VEHICLE ORIENTED BUSINESSES. ARTICLE 23. MOTOR VEHICLE ORIENTED BUSINESSES. Sec. 25-23.1. Conditional Use. Motor vehicle oriented businesses (MVOB) shall require a Conditional Use Permit in all districts as indicated in Appendix B,

More information

Barrier Free Design Guide

Barrier Free Design Guide 11-07 Department of Veterans Affairs Barrier Free Design Guide A Supplement to the Uniform Federal Accessibility Standards PG-18-13 November 2007 Office of 1 Construction & Facilities Management Facilities

More information

Parking Space and Drive Aisle Dimension Requirements June 2011

Parking Space and Drive Aisle Dimension Requirements June 2011 Parking Space and Drive Aisle Dimension Requirements June 2011 What are your code s minimum dimension requirements for a standard parking space? Municipality Parallel Space Angle Space Are there any standard

More information

EVCS Access California

EVCS Access California EVCS Access California New Accessibility Regulations for Electric Vehicle Charging Stations Ida A. Clair AIA, LEED AP, CASp California Department of General Services Division of the State Architect Sacramento,

More information

Please direct all questions regarding this policy and its administration to:

Please direct all questions regarding this policy and its administration to: CITY of OAKLAND DEPARTMENT of TRANSPORTATION Subject: Accessible On-Street Parking Policy Effective Date: October 12, 2017 Supersedes: On-Street Disabled Parking Zone Policy (July 1, 2009) Reference: U.S.

More information

BILLERICA OPEN SPACE AND RECREATION PLAN

BILLERICA OPEN SPACE AND RECREATION PLAN BILLERICA OPEN SPACE AND RECREATION PLAN AMERICANS WITH DISABILITIES ACT INVENTORY OF ACTIVE RECREATION FACILITIES WITH SUPPORTING FACILITY PHOTOGRAPHS AND RECOMMENDATIONS BY MEMBERS OF THE COMMISSION

More information

TRAFFIC MANAGEMENT STANDARDS CITY OF GARLAND TRANSPORTATION DEPARTMENT

TRAFFIC MANAGEMENT STANDARDS CITY OF GARLAND TRANSPORTATION DEPARTMENT TRAFFIC MANAGEMENT STANDARDS CITY OF GARLAND TRANSPORTATION DEPARTMENT JUNE 1996 TABLE OF CONTENTS 1.0 Street Design Standards 1.1 Right-of-Way Requirements 1.2 Median Openings 1.3 Sidewalks 1.4 Traffic

More information

TRAFFIC CONTROL REGULATIONS

TRAFFIC CONTROL REGULATIONS TRAFFIC CONTROL REGULATIONS Town of Southampton Applies to: Vehicles and Traffic in the Town of Southampton Select Board Original Adoption: November 2, 2017 Amended on: -- Last Reviewed by Select Board:

More information

St. Catharines Transit Commission Accessibility Plan. St. Catharines Transit Commission Accessibility Plan

St. Catharines Transit Commission Accessibility Plan. St. Catharines Transit Commission Accessibility Plan St. Catharines Transit Commission 2013-2018 Accessibility Plan 1 2013-2018 ST. CATHARINES TRANSIT ACCESSIBILITY PLAN The following document is the St. Catharines Transit s Accessibility Plan for the next

More information

ChapterS ACCESSIBLE BUILDINGS & FACILITIES Code References 1.) Plumbing fixtures conforming to "Accessible Buildings & Facilities"

ChapterS ACCESSIBLE BUILDINGS & FACILITIES Code References 1.) Plumbing fixtures conforming to Accessible Buildings & Facilities ACCESSBLE BULDNGS & FACLTES Code References 1.) Plumbing fixtures conforming to "Accessible Buildings & Facilities" a. Accessible water closets (wheelchair-accessible): (1) Number of wheelchair-accessible

More information

Terminal Alternatives

Terminal Alternatives Chapter 5 Terminal Alternatives Missoula International Airport Master Plan Update Prepared for Missoula County Airport Authority OCTOBER 2008 Contents Section Page 5 Terminal Alternatives...5-1 5.1 Terminal

More information

DISCUSSION For the purpose of this General Order, the following definitions shall apply:

DISCUSSION For the purpose of this General Order, the following definitions shall apply: TYPE OF ORDER NUMBER/SERIES General Order 140.04 SUBJECT TITLE Public Safety Complex Parking Plan REFERENCE N/A SUBJECT AREA Administration ISSUE DATE EFFECTIVE DATE 2/1/2013 2/3/2013 PREVIOUSLY ISSUED

More information

Expedited Permitting Process for Electric Vehicle Charging Stations

Expedited Permitting Process for Electric Vehicle Charging Stations Expedited Permitting Process for Electric Vehicle Charging Stations BPC-062 Purpose: This document provides all of the needed links to forms and checklists necessary to utilize Permit Sonoma s Expedited

More information

INFORMATION BULLETIN / PUBLIC - ZONING CODE REFERENCE NO.: L.A.M.C A5 Effective: DOCUMENT NO.: P/ZC Revised:

INFORMATION BULLETIN / PUBLIC - ZONING CODE REFERENCE NO.: L.A.M.C A5 Effective: DOCUMENT NO.: P/ZC Revised: INFORMATION BULLETIN / PUBLIC - ZONING CODE REFERENCE NO.: L.A.M.C. 12.21A5 Effective: 10-01-1999 DOCUMENT NO.: P/ZC 2002-001 Revised: 11-28-2018 Previously Issued As: IB ZO-1, RGA 3-72 PARKING DESIGN

More information

I-290 Phase I Study Summary of NFPA-130 Analysis of Proposed CTA Station Platform Widths May 2016

I-290 Phase I Study Summary of NFPA-130 Analysis of Proposed CTA Station Platform Widths May 2016 I-290 Phase I Study Summary of NFPA-130 Analysis of Proposed CTA Station Platform Widths May 2016 INTRODUCTION As part of the I-290 reconstruction phase I study, IDOT has coordinated with the CTA regarding

More information

ORDINANCE NUMBER 3424

ORDINANCE NUMBER 3424 ORDINANCE NUMBER 3424 AN ORDINANCE OF THE MISSOULA CITY COUNCIL AMENDING TITLE 12 STREETS, SIDEWALKS AND PUBLIC PLACES TO ADD CHAPTER 12.22 ENTITLED "PARKING FACILITIES," SECTIONS 12.22.010 THROUGH 12.22.130

More information

Plan Check Policies and Guidelines

Plan Check Policies and Guidelines Plan Check Policies and Guidelines VII. A. INTRODUCTION Traffic signing and striping plans are required for all General Plan Roads and any roadway that is 56-foot wide curb-to-curb (78 R/W) or wider. Transportation

More information

STANDARD DRAWING INDEX

STANDARD DRAWING INDEX ATTACHMENT B STANDARD DRAWING INDEX DESCRIPTION EXISTING DRAWING NO. GENERAL Typical Layout for Improvement Plans City of Stockton Standard Border and Title Block for 8 1/2 x11 Sheet City of Stockton Standard

More information

Standards for Barrier-Free Campus Office for Students with Disabilities University Planning Office June 2004

Standards for Barrier-Free Campus Office for Students with Disabilities University Planning Office June 2004 Standards for Barrier-Free Campus Office for Students with Disabilities University Planning Office June 2004 F:\PROJECTS\Disabled\ACCESS04.doc INTRODUCTION The McGill standards for barrier-free and universal

More information

Design of Parking Facilities. Design of Parking Facilities. Location of Parking Facilities

Design of Parking Facilities. Design of Parking Facilities. Location of Parking Facilities Design of Parking Facilities Design of Parking Facilities Location Type of Operations Surface Car Parks Parking Garage / Underground Access Layout Pedestrian Bus / Truck Terminal Other Consideration Location

More information

150 OFF-STREET PARKING AND LOADING REGULATIONS

150 OFF-STREET PARKING AND LOADING REGULATIONS 150 OFF-STREET PARKING AND LOADING REGULATIONS (B/L 2454-2015) 150.1 Applicability.1 The off-street parking and loading regulations in this section apply to: a. a proposed building or structure; b. a building

More information

Enhanced Accessibility in the ICC/A Pacific ADA Update Conference Presented by: Kermit Robinson, CBO International Code Council

Enhanced Accessibility in the ICC/A Pacific ADA Update Conference Presented by: Kermit Robinson, CBO International Code Council Enhanced Accessibility in the ICC/A117.1 2017 2017 Pacific ADA Update Conference Presented by: Kermit Robinson, CBO International Code Council Requirements Scoping : What, Where and How Many 2015 IBC and

More information

Operations Center FAQs

Operations Center FAQs RICHARDSON INDEPENDENT SCHOOL DISTRICT Where all students learn, grow and succeed Operations Center FAQs Richardson ISD is constructing an operations center on vacant district land between Greenville Avenue

More information

PACIFIC FAIR ACCESS STATEMENT. Using this document. Facility Summary. Facility details

PACIFIC FAIR ACCESS STATEMENT. Using this document. Facility Summary. Facility details PACIFIC FAIR ACCESS STATEMENT At Pacific Fair we aim to ensure everyone's experience is as enjoyable as possible. We are committed to providing suitable access for all our guests, whatever their individual

More information

Parking Regulations. Responsibility

Parking Regulations. Responsibility Parking Regulations International University of Sarajevo (IUS), Foundation for Education Development Sarajevo, and Sedef Bosnia d.o.o. welcomes you, the motorist, on campus. Students, faculty, staff and

More information

Chapter ACCESS, PARKING AND TRAFFIC*

Chapter ACCESS, PARKING AND TRAFFIC* Chapter 49.40 ACCESS, PARKING AND TRAFFIC* *Administrative Code of Regulations cross reference--access, parking and traffic, Part IV, 04 CBJAC 025.010 et seq. Cross References: Traffic, CBJ Code tit. 72.

More information

Chapter 17 TRAFFIC AND VEHICLES. Adoption of Uniform Rules of the Road. Temporary Traffic Regulations.

Chapter 17 TRAFFIC AND VEHICLES. Adoption of Uniform Rules of the Road. Temporary Traffic Regulations. Chapter 17 TRAFFIC AND VEHICLES Article I. Article II. Article III. In General. Section 17.1 Adoption of Uniform Rules of the Road. Section 17.2 Temporary Traffic Regulations. Section 17.3 Traffic Speed,

More information

Fire Apparatus Access Roads in Marysville

Fire Apparatus Access Roads in Marysville Fire Apparatus Access Roads in Marysville 1094 Cedar Avenue, Marysville, Washington 98270 Phone (360) 363-8500 Fax (360) 659-1382 These documents all address various requirements for Fire Apparatus Access

More information

TRAFFIC PARKING ANALYSIS

TRAFFIC PARKING ANALYSIS TRAFFIC PARKING ANALYSIS NAPA FLEA MARKET COUNTY OF NAPA Prepared for: Tom Harding Napa-Vallejo Flea Market 33 Kelly Road American Canyon, CA 9453 Prepared by: 166 Olympic Boulevard, Suite 21 Walnut Creek,

More information

CHAPTER 69 PARKING REGULATIONS

CHAPTER 69 PARKING REGULATIONS 69.01 Parking Limited or Controlled 69.08 Persons with Disabilities Parking 69.02 Park Adjacent to Curb 69.09 Truck Parking Limited 69.03 Park Adjacent to Curb One-way Street 69.10 Snow Removal 69.04 Angle

More information

TOWN OF MARANA, ARIZONA LAND DEVELOPMENT CODE

TOWN OF MARANA, ARIZONA LAND DEVELOPMENT CODE TITLE 22 OFF-STREET PARKING AND LOADING SECTIONS: 22.000 Purpose 22.010 When required 22.020 Size and access requirements 22.030 Number of spaces required for designated uses 22.050 Parking areas-development

More information

SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS

SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS Kitsap County Public Works July 2019 If you have any questions regarding the Standards or have recommendations for improvement, please contact: Sarah Olson

More information

DRAFT Commission, based upon the requirements of comparable uses listed.

DRAFT Commission, based upon the requirements of comparable uses listed. Chapter 345 OFF-STREET PARKING AND LOADING 345.01 Purpose 345.02 General Provisions 345.03 Off-Street Parking Standards 345.04 Off-Street Loading Standards Commission, based upon the requirements of comparable

More information

Moraga-Orinda Fire District

Moraga-Orinda Fire District Moraga-Orinda Fire District Fire Prevention Division Subject: Fire Apparatus Access Roads Approved by: Fire Marshal Kathy Leonard Reference: CFC 2016, MOFD Ordinance 16-02 Standard Number: 2016.503 Effective

More information

ACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS

ACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LABC Chapter 11B Effective: 07/01/2018 DOCUMENT NO.: P/BC 2018-087 Revised: 07/01/2018 ACCESSIBILITY DETAILS FOR RESTROOMS AND S 60 " C 6 "

More information

The minimum number of accessory off-street parking spaces. shall conform to the requirements of the Table of General

The minimum number of accessory off-street parking spaces. shall conform to the requirements of the Table of General ARTICLE VII Parking and Loading 1. Conformity with Use Table; exceptions. The minimum number of accessory off-street parking spaces shall conform to the requirements of the Table of General Use Regulations,

More information

41 One Gateway Plaza Los Angeles, CA

41 One Gateway Plaza Los Angeles, CA 41 One Gateway Plaza Los Angeles, CA 90012-2952 213.922.20C metro. net SYSTEM SAFETY AND OPERATIONS COMMITTEE FEBRUARY 21, 2013 EXECUTIVE MANAGEMENT COMMITTEE FEBRUARY 21, 2013 SUBJECT: ACTION: ADMINISTRATIVE

More information

Title 33, Planning and Zoning Chapter /1/11 Parking And Loading

Title 33, Planning and Zoning Chapter /1/11 Parking And Loading Title 33, Planning and Zoning Chapter 33.266 7/1/11 Parking And Loading CHAPTER 33.266 PARKING AND LOADING (Amended by: Ord. No. 164014, effective 3/27/91; Ord. No. 164899, effective 12/11/91; Ord. No.

More information

IMPROVEMENT CONCEPTS

IMPROVEMENT CONCEPTS IMPROVEMENT CONCEPTS for the South Novato Transit Hub Study Prepared by: January 11, 2010 DKS Associates With Wilbur Smith Associates IMPROVEMENT CONCEPTS Chapter 1: Introduction 1. INTRODUCTION The strategic

More information