1 OLEOIDRAULICA RACCOMANDAZIONI CETOP ELIMINATE & CORRISPONDENTI NORMATIVE ISO Rif/Data Titolo & Normativa(e) ISO collegata(e) R 6H 1979 Pipe couplings for hydraulic piping - coupling thread see ISO 6149 (preferred), ISO 1179, ISO 9974 R 8H RP 9H 1964 R 10H 1979 R 11H RP 12H 1967 Definitions and symbols of performance characteristics - pumps, motors and integral transmissions see ISO 4391 Technical conditions of delivery no longer relevant Hydraulic cylinder - Cylinder internal diameters and rod diameter - Sizes of threaded rods and ports - Nominal pressures - Piston strokes see ISO 3320, 3321, 3322, 4393, 4395, 7181, 8136, 8137, 8138 Recommendations for installation, commissioning and maintenance of complete hydraulic systems see ISO 4413 Recommendations for starting, servicing and maintenance of hydraulic power pumps RP 13H 1967 P 14H 1967 RP 15H RP 16H RP 17H Recommendations for starting, servicing and maintenance of hydraulic motors Recommendations for starting, servicing and maintenance of complete hydraulic transmissions Related ISO Standards: ISO 4413 Recommendations for starting, servicing and maintenance of hydraulic valves no longer relevant Recommendations for starting, servicing and maintenance of hydraulic cylinders no longer relevant Recommendations for starting, maintenance and servicing of hydraulic intensifiers no longer relevant. RP 18H Recommendations for installation, commissioning and maintenance of hydraulic accumulators no longer relevant. 1

2 R 34 R 35H R 39H (revised) RP 41 RP 47H R 48H ) RP 55H 1995 RP 56H R 58H RP 60H RP 62H RP 63H RP 64H 1992) RP 65H 1993) RP 66H Couplings for fluid power hoses see ISO 12151, Parts 1-5 Mounting surfaces for hydraulic directional valves - see RP 121H Schedule of required data for hydraulic fluids This document has been prepared to assist fluid suppliers, equipment manufacturers and users to determine the data which can be made available for each hydraulic fluid and agreed means for stating this data. Hydraulic and pneumatic systems - Circuit diagrams see ISO Recommendations for the design, manufacture and safe application of gas-loaded hydraulic accumulators see EN 982 & ISO 4413 Evaluation of the anti-corrosive qualities of water based fire resistant fluids A laboratory bench-top method is described to measure the effect of water based fluids on specified metals. Related ISO Standards: ISO & ISO This recommendation is effectively superseded by ISO A method specific to HFD-type fluids is in development in CEN/TC19 (ISO ) Schedule of fire resistant tests for fire resistant fluids A revised version of the document. Lists test procedures for determining the low inflammability of pressure fluids. Test method to determine the fire resistance of FR fluids using a CFR (Co-operative Fuel Research) engine at variable compression speed (based on ASTM D T) - due to lack of test-rigs Hydraulic cylinders bar - Medium series - Mounting dimensions - Bores 25 to 500 mm see ISO Specification for oil hydraulic piston rods see ISO 3320 & 3321 Definitions and symbols of the operating characteristics of gas-loaded hydraulic accumulators see ISO 5596 Square flange connections for hydraulic piping see ISO 6162, 6163, 6164 Effect of evaporation on flammability This method is used for determining the effect of evaporation on the flammability of a fire resistant fluid. It consists of checking the flammability of the liquid, storing the sample in an oven for the time and at the temperature required by the specification and rechecking flammability. Manifold ignition test This method is used for determining the relative flammability of a liquid in contact with hot surface. *A possible replacement for this recommendation is in development in CEN/TC19, EN ISO Wick test see ISO

3 RP 67H (revised 1999) RP 69H RP 70H RP 71 RP 72H 1992) RP 73H RP 75H RP 76 RP 77H RP 78H RP 80 R 81H RP 86H 1979 RP 87H RP 88H R 89H RP 91H 1988 RP 92H RP 93H Anti-wear vane pump test for hydraulic fluids This test assesses the anti-wear properties of hydraulic fluids by means of a vane type hydraulic pump. It is for fluids intended for use in applications with high speed sliding contacts such as are encountered in a vane pump.. *A possible replacement for this recommendation is in development in CEN/TC19, EN ISO Hydraulic fluid power - mounting surfaces for flow control, pressure control and check valves - see RP 121H Identification code for the level of solid contaminant in hydraulic fluids - see ISO 4406 Quantities, symbols and units of the international system (SI) to be used for fluid power - see ISO 1000 Evaporation test for fire resistant fluid type HFC This test determines the rate of evaporation and checks that during evaporation no hard or waxy deposits are formed. Hydraulic cylinders bar mounting dimensions - bores 50 to 500 mm see ISO 6022 Fluids for hydraulic transmissions - mineral oils - classification - see ISO Outside diameters for tubes in fluid power applications - see ISO 4397 Fluids for hydraulic transmissions - fire resistant fluids - classification - see ISO Hydraulic cylinders - tolerances see ISO 8131 & 8135 Cone type connection - 24 degree - for fluid power tubes and hoses see ISO , , Compatibility of hydraulic fluids with elastomeric materials - see ISO 6072 Guidelines for the use of fire-resistant fluids in hydraulic systems see ISO 7745 & EN ISO Hydraulic cylinders - mounting dimensions for rod end plain eye see ISO 6981 Hydraulic cylinders - mounting dimensions for rod end spherical eye see ISO 6982 Fluids for hydraulic systems - mineral oils - stability corrosion test 1991 Fluids for hydraulic transmission mineral oils - specifications see ISO Statement of requirements for filters in hydraulic systems - see ISO 7744 Anti-wear test for hydraulic fluids using an internal gear type steering motor

4 RP 94H RP 95H RP 96H 1980 RP 97H 1989 RP 98H 1979 RP 99H 1982 RP RP 101 RP 104H 1982 RP 106H RP 108H 1991 RP 109H ) RP 110H RP 112H 1984 RT 113H RP 115H Determination of particulate matter in hydraulic fluids using an automatic size analyser employing the light interruption principle see ISO Recommended method for the bottle sampling of hydraulic fluids for particle counting - see ISO 4021 Hydraulic fluid power - cavities for two-port slip-in cartridge valves see ISO 7368 Fluids for hydraulic transmission - fire-resistant fluids - specification see ISO Guidelines for the specification, selection and application of hydraulic reservoir air breather filters see ISO 7744 Hydraulic fluid power - modular stack and directional control valves - sizes 03 and 05 - clamping dimensions see ISO 7790 Hydraulic and pneumatic fluid power glossary see ISO 5598 Lexicon of terms from the hydraulic and pneumatic fluid power glossary see ISO 5598 Hydraulic fluid power - acceptance test for hydraulic cylinders see ISO Hydraulic quick action couplings - see ISO Hydraulic fluid power 2, 3 and 4 port screw-in cartridge valve cavities see ISO 7789 Hydraulic fluid power - Filter elements - Low temperature integrity test This is a standard method for carrying out a low temperature test on filter elements to verify the ability of a filter element to withstand such a test and maintain its performance integrity. Fluids for hydraulic transmission - Fire-resistant fluids - Category HFA - Specifications This document gives the required values for HFAE and HFAS fluids; the concentrates and test waters. Suggestions are also given for the production, operation, care, supervision and disposal of the diluted fluid. Related ISO Standards: ISO (see also ISO 7745) Fluids for hydraulic transmission - Mineral oil category HV - Method for determination of shear stability This document describes a standard procedure for determining the resistance to shear of hydraulic fluids containing polymers (for more modern method see RP 122H). Fluids for hydraulic transmission - Disposal methods for used oil/water emulsions Special problems and difficulties arise in the disposal of used oil/water emulsions and water soluble hydraulic fluids. 13 methods are shown in a chart and further details are given for 8 of the preferred methods. Hydraulic fluid power - 4 port and 5 port servo-valves - Mounting surfaces see ISO

5 RT 117H RT 118H 1988 RP 121H 1991 RP 122H 1995 RP 123H 1995 RP 124H 1995 Hydraulic fluid power - Flushing of hydraulic systems Flushing is a procedure which is vital to the operation and life of a hydraulic system. This document provides guidance applicable to all systems. Guidelines to the contamination control in hydraulic fluid power systems Most hydraulic component failures are due to the presence of abrasive contaminant in the fluid. Clean hydraulic fluid is the key to reliability and effective contamination control is the way to achieve and maintain this.. An updated guide, BFPA/P5 is available from BFPA. Hydraulic fluid power - Mounting surfaces for flow directional, pressure control, check and flow control valves This document is an update of the previous documents R 35H and RP 69H. Related ISO Standards: ISO 4401, ISO 5781, ISO 6263, ISO 6264 Viscosity Shear Stability of Hydraulic Oils (Taper Roller Bearing Rig) see CEC L-45-A-99 Classification of ecologically acceptable hydraulic fluids see ISO Procedure for the determination of the filterability of hydraulic and lubrication oils - procedure for 'dry' oils see ISO (or ISO for wet oils) Key to abbreviations CETOP R : Recommendation RP : Provisional Recommendation RT : Technical Report H : Hydraulic P : Pneumatic 5

6 PNEUMATICA RACCOMANDAZIONI CETOP ELIMINATE & CORRISPONDENTI NORMATIVE ISO Rif/Data RP 4P 1964 RP 5P 1964 RP 19P to RP 30P & RP 57P RP 19P RP 20P RP 21P RP 22P RP 23P RP 24P RP 25P Titolo & Normativa(e) ISO collegata(e) Pneumatic cylinders - Suggested data for inclusion as a minimum in manufacturers sales and literature This document contains the most important data for pneumatic cylinders. This data should be specified by the manufacturer in order to permit optimum utilisation. Two charts are included which give safe loads for piston rods. Specification for pneumatic cylinders Specification applies to pneumatic cylinders for normal operating conditions. RECOMMENDED DATA FOR INCLUSION IN MANUFACTURERS' SALES LITERATURE The characteristics given are based on the appropriate CETOP recommendations and national standards. Pneumatic directional control valves Data covering general and pneumatic characteristics, method of actuation and response times are given. Pneumatic flow control valves Data covering general and pneumatic characteristics and method of actuation are given. Pressure control valves - see ISO 6953 Pneumatic shuttle, non-return and quick exhaust valves Data covering general and pneumatic characteristics and methods of actuation are given. Pneumatic pressure intensifiers Data covering general, pneumatic, hydraulic and pneumatic-hydraulic characteristics are given. Pneumatic rectilinear piston type cylinders Data covering general and pneumatic characteristics are given Filters and water traps - see ISO 5782 RP 26P Lubricators - see ISO

7 RP 27P RP 28P 1968 RP 29P 1969 RP 30P 1969 RP 33P R 34 RP 37P RP 38P 1970 RP 40P RP 41 RP 43P RP 44P RP 46P RP 49P 1972 RP 54P RP 57P 1972 RP 68P 1989 Air Dryers Connections Data on dimensions, tubing working conditions and applications are given. Pneumatic quick action couplings Reference is made to RP 28P with additional data given relevant to quick action couplings. Related ISO Standards: ISO 6150 Pneumatic rotating and telescopic joints Descriptive and working condition characteristics are given. Graphical symbols and definitions for logic and related function in fluid logic circuits Couplings for fluid power hoses Dimensions of couplings for fluid power hoses. Hose bore range 3.2 to 51 mm. Related ISO Standards: ISO 8434 Recommended diameters for pneumatic tubes and hoses Guidance on relation between port threads and pipe hose diameters This document states the recommended outside diameters for tubes and inside diameters for hoses related to certain port threads. Hose couplings, claw type This document states the connecting dimensions of recommended couplings up to 10 bar working pressure. Hydraulic and pneumatic systems - Circuit diagrams see ISO Pneumatic cylinders - 10 bar operating - operating conditions and dimensions - bores 32 to 100 mm Pneumatic fluid power glossary - see ISO 5598 Units for fluid logic components and systems to be used in manufacturers' technical sales literature Technological symbols for fluid logic and related devices with and without moving parts see ISO 5784 Specification for polyamide tubing 11 and 12 for pneumatic transmissions Data on quality and dimensions of nylon tubing over the size range 4 to 28mm OD are given. Pressure relief valves - Recommended data for inclusion in manufacturers technical sales literature Characteristics are given for general data, pneumatic features and method of loading. This is a further document in the series RP 19P to RP 30P. Rules for the identification of ports and operators of pneumatic control valves and other pneumatic components see ISO

8 RP 71 RP 76 RP 80 RP 82P RP 85P RP RP RP 105P 1982 RP 107P 1981 RP 111P 1989 RP 114P Quantities, symbols and units of the International System (SI) to be used for fluid power - see ISO 1000 Outside diameters for tubes in fluid power applications - see ISO 4397 Cone type connections for fluid power tubes and hoses see ISO , , Response time characteristics of pneumatic directional control valves in favour of RP 111P Characteristics of pneumatic components Hydraulic and pneumatic fluid power glossary see ISO 5598 Lexicon of terms from the hydraulic and pneumatic fluid power glossary see ISO 5598 Acceptance test for pneumatic cylinders see ISO Fixed pivot bracket for pneumatic cylinders see ISO/DIS Switching characteristics of pneumatic directional control valves and moving part logic components This document defines the switching characteristics of pneumatic directional control valves and moving part logic components, and explains the methods and equipment used in their measurement. It supersedes RP 82P: 1977 which is now withdrawn. Related ISO Standard: ISO Pneumatic valves, subplates for five-port valves with mounting surfaces in accordance with ISO see ISO 5599 Key to abbreviations CETOP R : Recommendation RP : Provisional Recommendation RT : Technical Report H : Hydraulic P : Pneumatic ISO DIS : Draft International Standard 3

Number Title Year Organization Page

Number Title Year Organization Page Id Number Title Year Organization Page 365528 B93.1 Dimension Identification Code for Fluid Power Cylinders; Appendices I and II (NFP(A) T3.6.2-1964) R(1994) 365529 B93.2 Fluid Power Systems and Products

More information

Axial Piston Units for Use with HF Fluids

Axial Piston Units for Use with HF Fluids RE 90 223/11.99 Replaces: 09.90 Axial Piston Units for Use with HF Fluids For mineral oil based fluids for axial piston units, see data sheet RE 90220 For environmentally acceptable fluids for axial piston

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 11158 Second edition 2009-09-15 Corrected version 2009-12-01 Lubricants, industrial oils and related products (class L) Family H (hydraulic systems)

More information

ISO INTERNATIONAL STANDARD. Lubricants, industrial oils and related products (Class L) Family X (Greases) Specification

ISO INTERNATIONAL STANDARD. Lubricants, industrial oils and related products (Class L) Family X (Greases) Specification INTERNATIONAL STANDARD ISO 12924 First edition 2010-05-01 Lubricants, industrial oils and related products (Class L) Family X (Greases) Specification Lubrifiants, huiles industrielles et produits connexes

More information

CETOP POSITION PAPER PP 07

CETOP POSITION PAPER PP 07 CETOP POSITION PAPER PP 07 MACHINERY DIRECTIVE 2006/42/EC Valid since 26 th May 2010 CETOP General Secretariat Lyoner Straße 18 D-60528 Frankfurt am Main Phone: +49 69 6603 1201 Fax: +49 69 6603 2201 E-mail:

More information

In line high pressure filters. HF 725 series

In line high pressure filters. HF 725 series In line high pressure filters HF 725 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

PNEUMATIC PUMP Series

PNEUMATIC PUMP Series PNEUMATIC PUMP Series 3103... User and Maintenance Manual Original text translation TABLE OF CONTENTS 1. INTRODUCTION 2. GENERAL DESCRIPTION 3. PRODUCT-MACHINE IDENTIFICATION 4. TECHNICAL CHARACTERISTICS

More information

Intermot Hydraulic Motors. Drum Brakes RC Series

Intermot Hydraulic Motors. Drum Brakes RC Series Intermot Hydraulic Motors Drum Brakes RC Series TECHNICAL CATALOGUE INDEX General information Pag. 10 Technical data Pag. 14 Dimensional drawings Pag. 15 Ordering instructions Pag. 17 9 Hydraulic fluids

More information

In line high pressure filters. HF 735 series

In line high pressure filters. HF 735 series In line high pressure filters HF 735 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the fluid.

More information

RENEP CGLP. High-performance slideway oils for machine tools, with excellent demulsification properties. Description. Advantages

RENEP CGLP. High-performance slideway oils for machine tools, with excellent demulsification properties. Description. Advantages Description The quality of machined components depends heavily on the accurate feed and accurate positioning provided by machine tool slideways with slideway oils playing an important role. Slideway oils

More information

Applications of Pneumatics and Hydraulics

Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 Aim This unit aims to extend learners understanding of pneumatic and hydraulic fluid power systems

More information

British Standard institute-bs Valve Standards

British Standard institute-bs Valve Standards BS 341-1:1991 Transportable gas container valves. Specification for industrial valves for working pressures up to and including 300 bar (REPLACED by BS EN 14189:2003), BS 341-3:2002), BS EN 849:1997),

More information

ISO 6022 INTERNATIONAL STANDARD. Hydraulic fluid power Mounting dimensions for single rod cylinders, 25 MPa (250 bar) series

ISO 6022 INTERNATIONAL STANDARD. Hydraulic fluid power Mounting dimensions for single rod cylinders, 25 MPa (250 bar) series INTERNATIONAL STANDARD ISO 6022 Second edition 2006-02-01 Hydraulic fluid power Mounting dimensions for single rod cylinders, 25 MPa (250 bar) series Transmissions hydrauliques Dimensions d'interchangeabilité

More information

1410 Series & 4413 / 4423 Series Intrinsically Safe Solenoid Operated Directional Control Valves & Pilot Valves for Marine Applications

1410 Series & 4413 / 4423 Series Intrinsically Safe Solenoid Operated Directional Control Valves & Pilot Valves for Marine Applications 1410 Series & 4413 / 4423 Series Intrinsically Safe Solenoid Operated Directional Control Valves & Pilot Valves for Marine Applications Intrinsically safe solenoid operated pilot valve 1410 Series The

More information

SINGLE ACTING METRIC RANGE

SINGLE ACTING METRIC RANGE CONTENTS Page 2 General specifications Ram Style No. Female Rod Male Rod Pin Hole 3 Part Numbering System 4 Dimensions 5 Buckling Calculations 6 Buckling Force/ Graphs 7 Load Calculations 8 PBV Flow Chart

More information

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07 Throttle check valve Type ZFS RE 758 Edition: 06-0 Replaces: 0.07 Size 0 Component series 3X Maximum operating pressure 35 bar [4569 psi] Maximum flow 60 l/min [4.3 US gpm] H5556 Features Sandwich plate

More information

DOUBLE ACTING METRIC RANGE

DOUBLE ACTING METRIC RANGE CONTENTS Page 2 General specifications Ram Style No. Female Rod Male Rod 3 Part Numbering System 4 Basic Dimensions 5 Load Calculations 6 Load Calculations 7 Buckling Calculations 8 Buckling Calculations

More information

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces: Pressure reducing valve, direct operated Type ZDR RE 657 Edition: 8-3 Replaces: 8- Size 6 Component series 4X Maximum operating pressure 35 bar Maximum flow 5 l/min H775 Features Sandwich plate valve Porting

More information

Oil Soluble Polyalkylene Glycol Hydraulic Fluid: Equipment Performance Testing and Case Study

Oil Soluble Polyalkylene Glycol Hydraulic Fluid: Equipment Performance Testing and Case Study Oil Soluble Polyalkylene Glycol Hydraulic Fluid: Equipment Performance Testing and Case Study Authors Andrew Larson, The Dow Chemical Company Dr. Martin Greaves, The Dow Chemical Company The Dow Chemical

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 10100 Second edition 2001-08-01 Hydraulic fluid power Cylinders Acceptance tests Transmissions hydrauliques Vérins Essais de réception Reference number ISO 10100:2001(E) ISO

More information

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND 48 900/103 ED LC* LP* LOGIC ELEMENTS CARTRIDGE VALVES ISO 7368 - DIN 24342 COVERS FOR CARTRIDGE VALVES ND 16-25-32-40-50 p max 420 bar Q max (see performance ratings table) OPERATING PRINCIPLE Logic elements

More information

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03 Pressure reducing valve, pilot operated Type DR RE 293 Edition: 2013-01 Replaces: 02.03 Sizes 10 and 2 Component series 1X; 4X Maximum operating pressure 31 bar Maximum flow 10 l/min H792 Features Contents

More information

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition: Pressure relief valve, direct operated Type DBD..K RE 25715 Edition: 2015-06 Size 2 Component series 2X Maximum operating pressure 420 bar Maximum flow 2 l/min H8070 Features Screw-in cartridge valve 6

More information

Nomenclature... xi Hydraulic Laws, Theorems, and Equations...xii

Nomenclature... xi Hydraulic Laws, Theorems, and Equations...xii Nomenclature... xi Hydraulic Laws, Theorems, and Equations...xii 1 Introduction 1.1 Component Design Perspective...1 1.2 Hydraulic Power Evolution...2 1.3 Hydraulic Applications...6 1.4 Component Design

More information

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground. Heat exchangers Air/Oil LAC - LAC with AC Motor for Industrial Use - Maximum cooling capacity 300 kw Heat exchangers Air/Oil LAC-X - ATEX Version. Approved for applications where there may be an explosive

More information

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed

More information

APP pump instruction APP 21-43

APP pump instruction APP 21-43 MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 21-43 ro-solutions.com Table of Contents 1. Identification...2 2. System design...3 2.1 Open-ended systems with direct water supply....3

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

FLUID POWER TUTORIAL HYDRAULIC PUMPS APPLIED PNEUMATICS AND HYDRAULICS H1

FLUID POWER TUTORIAL HYDRAULIC PUMPS APPLIED PNEUMATICS AND HYDRAULICS H1 FLUID POWER TUTORIAL HYDRAULIC PUMPS This work covers outcome 2 of the Edexcel standard module: APPLIED PNEUMATICS AND HYDRAULICS H1 The material needed for outcome 2 is very extensive so the tutorial

More information

NZQA unit standard version 5 Page 1 of 6. Demonstrate knowledge of engine design factors and machining practices

NZQA unit standard version 5 Page 1 of 6. Demonstrate knowledge of engine design factors and machining practices Page 1 of 6 Title Demonstrate knowledge of engine design factors and machining practices Level 4 Credits 20 Purpose People credited with this unit standard are able to demonstrate knowledge of engine design

More information

FLUID POWER SEALING SOLUTIONS TROUBLESHOOTING GUIDE

FLUID POWER SEALING SOLUTIONS TROUBLESHOOTING GUIDE FLUID POWER SEALING SOLUTIONS TROUBLESHOOTING GUIDE POLYMER SEALS This section provides troubleshooting criteria for Chesterton s hydraulic and pneumatic sealing devices. It should be used only as a general

More information

KE-M02 configuration Configuratie documentatie documentation KE-M02

KE-M02 configuration Configuratie documentatie documentation KE-M02 Configuratie documentatie KE-M02 1/32 2/32 3/32 4/32 5/32 General Technical Data for Compact Power Module KE series Through the years DCOC has developed a highly evolved modular system resulting in powerful,

More information

M-11 MARINE DIESEL ENGINE FUEL INJECTOR

M-11 MARINE DIESEL ENGINE FUEL INJECTOR Guideline No.M-11(201510) M-11 MARINE DIESEL ENGINE FUEL INJECTOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable

More information

THE IMPORTANCE OF AN EFFICIENT FILTRATION

THE IMPORTANCE OF AN EFFICIENT FILTRATION In line high pressure filters HF 745 / HF 748 series THE IMPORTANCE OF AN EFFICIENT FILTRATION The main cause of anomalies in hydraulic systems has to be attributed to the presence of contaminants in the

More information

Recommendation for petroleum fuel treatment systems for marine diesel engines

Recommendation for petroleum fuel treatment systems for marine diesel engines (July 2017) Recommendation for petroleum fuel treatment systems for marine diesel engines I Recommendation for the treatment of fuel oil on board ships 1 Application The following requirements should apply

More information

The range of products is completed by a number of accessories, including:

The range of products is completed by a number of accessories, including: ACCESSORIES The range of products is completed by a number of accessories, including: Foot brackets, which serve to support the motor-and-pump unit in the event that the selected electric motor does not

More information

VARIABLE VOLUME RESERVOIR (VVR) FOR INDUSTRIAL AND MOBILE APPLICATIONS

VARIABLE VOLUME RESERVOIR (VVR) FOR INDUSTRIAL AND MOBILE APPLICATIONS SOBACOR inc. 812 boul. Industriel Bois-des-Filion, Québec Canada J6Z 0A3 450-965-9669 450-965-9690 sobacor@sympatico.ca www.sobacor.com VARIABLE VOLUME RESERVOIR (VVR) FOR INDUSTRIAL AND MOBILE APPLICATIONS

More information

APP pump instruction APP and APP 16-22

APP pump instruction APP and APP 16-22 MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 11-13 and APP 16-22 www.ro-solutions.com Table of Contents 1. Identification...2 2. System design...3 2.1 Open-ended systems with direct

More information

Australian Standard. Pneumatic fluid power General requirements for systems (ISO 4414:1998, MOD) AS AS 2788

Australian Standard. Pneumatic fluid power General requirements for systems (ISO 4414:1998, MOD) AS AS 2788 AS 2788 2002 AS 2788 Australian Standard Pneumatic fluid power General requirements for systems (ISO 4414:1998, MOD) This Australian Standard was prepared by Committee ME-035, Fluid Power Systems and Components.

More information

ISO/TC 131/SC

ISO/TC 131/SC DRAFT INTERNATIONAL STANDARD ISO/DIS 6149-1 ISO/TC 131/SC 4 Connections for hydraulic fluid power and general use Ports and stud ends with ISO 261 metric threads and O-ring sealing Part 1: Ports with truncated

More information

ClaronPolyseal Single Acting Rod Seal PVM & PV

ClaronPolyseal Single Acting Rod Seal PVM & PV M & Metric tyle and M is a acting rod or piston seal for medium to heavy duty applications. The assembly consists of a male and female header and a series of 'V'. The number of 'V' may be varied to alter

More information

Series RFL In-Line Filter

Series RFL In-Line Filter APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction

More information

Fluid Power with Applications

Fluid Power with Applications Fluid Power with Applications Sixth Edition Anthony Esposito Professor Emeritus Department of Manufacturing Engineering Miami University Oxford, Ohio Prentice Hall Upper Saddle River, New Jersey Columbus,

More information

Terresolve Biodegradable Products High Performance Environmentally Safe

Terresolve Biodegradable Products High Performance Environmentally Safe Terresolve Biodegradable Products High Performance Environmentally Safe Terresolve Technologies 9609 Jackson Street, Mentor, Oh, 44060 800-661-3558 www.terresolve.com Environmental Products Have Been Used

More information

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Mounting dimensions for single rod cylinders, 16 MPa (160 bar) series Part 1: Medium series

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Mounting dimensions for single rod cylinders, 16 MPa (160 bar) series Part 1: Medium series INTERNATIONAL STANDARD ISO 6020-1 Third edition 2007-08-15 Hydraulic fluid power Mounting dimensions for single rod cylinders, 16 MPa (160 bar) series Part 1: Medium series Transmissions hydrauliques Dimensions

More information

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product

More information

HIGH PRESSURE FILTERS Series HF2P

HIGH PRESSURE FILTERS Series HF2P HIGH PRESSURE FILTERS Series HF2P Pressures to 3000 psi Flows to 25 GPM Port Size 3/4 APPLICATION HYDAC HF2 Inline High- Pressure Filters are designed for use on hydraulic power units, machine tools, plastics,

More information

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium:

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium: Settima screw a. Medium: HL oil conforming to DIN 51524 Parts 2 and 3 Special media such as: HFA min 5% oil HFB min 40% oil HFC max. 35-55% water HFDR high-viscosity lubricants SKYDROL, MIL-H may also

More information

Shut-off valves in stainless steel SVA-S SS

Shut-off valves in stainless steel SVA-S SS Technical brochure Shut-off valves in stainless steel In certain specific areas such as outdoor applications and corrosive atmospheres, such as coastal installations, there is a need for high surface protection

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) REVISION 1 REFERENCE EEAM-Q-002 (ORIGINAL SPECIFICATION HE9.2.2 Ver6) DOCUMENT TYPE: SPECIFICATION TITLE: SPECIFICATION FOR HYDRAULIC EQUIPMENT PAGE 0 of 09 COMPILED BY REVIEWED BY REVIEWED BY PROJECT

More information

RENOSAFE FireProtect 46, 68 Fire resistant hydraulic fluid, based on new ester and additive technology, Type HFDU

RENOSAFE FireProtect 46, 68 Fire resistant hydraulic fluid, based on new ester and additive technology, Type HFDU Description RENOSAFE FireProtect products are fire resistant hydraulic fluids based on special synthetic esters. The selected organic ester base oils have highest purity and show high oxidation and thermal

More information

RANDO HDZ. Rando HDZ, our premium, zinc additized, anti-wear hydraulic oil that helps provide you with:

RANDO HDZ. Rando HDZ, our premium, zinc additized, anti-wear hydraulic oil that helps provide you with: HYDRAULIC OILS RANDO HDZ The demands on your equipment, time and bottom line multiply daily. Rando HDZ helps keep your equipment operating longer, faster and harder, allowing you to extend the time between

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block

More information

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition: Pressure reducing valve, pilot-operated Type Z3DR RE 26874 Edition: 206-0 Size 0 Component series X Maximum operating pressure 350 bar Flow 20 l/min H8078 Features Sandwich plate valve Porting pattern

More information

[You may download this article at: https://fluidsys.org/downloads/ ]

[You may download this article at: https://fluidsys.org/downloads/ ] Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org

More information

Dancal (india) Pvt. Ltd.

Dancal (india) Pvt. Ltd. +91-8071676024 Dancal (india) Pvt. Ltd. https://www.indiamart.com/dancalindia/ We have established ourselves as the affluent Manufacturer and Supplier of a superior quality array of Double Acting Power

More information

Series RFLD Duplex In-Line Filter

Series RFLD Duplex In-Line Filter APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.

More information

MOTORS MV HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

MOTORS MV HYDRAULIC MOTORS T E C H N I C A L C A T A L O G OTORS V HYDRAULIC OTORS T E C H N I C A L C A T A L O G otors V - Hydraulic otors POCLAIN HYDRAULICS OVERVIEW Displacement Speed V2 V3 aximum cm³/rev [in³/rev.] From 3 [2.14] to 3 [3.23] From [3.3] to

More information

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10 Check valve Type ZS RE 537 Edition: 05-06 Replaces: 09.0 Size 0 Component series 4X Maximum operating pressure 350 bar [5076 psi] Maximum flow 00 l/min [6.4 US gpm] H7647 Features Sandwich plate valve

More information

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13 Accumulator shut-off block Type ABZSS RE 011 Edition: 2016-07 Replaces: 0.1 Nominal diameter DN08; DN10; DN20; DN0 Component series X Maximum operating pressure 0 bar [07 psi] HAD8066 Contents Features

More information

Product Specifications for Phase Over Phase GOABS(r)

Product Specifications for Phase Over Phase GOABS(r) 1. General a) This specification covers the design, manufacture, and shipment of phase-over-phase, 1-way, 2-way, 3-way, and 4-way, gang-operated disconnecting switches, both air-break and load-break, for

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD First edition 1996-04-15 Connections for general use and fluid power - Ports and stud ends with IS0 261 threads with elastomeric or metal-to-metal sealing - Part 3: Stud ends with

More information

Servo-hydraulic Universal Testing Machine HUT Type DP

Servo-hydraulic Universal Testing Machine HUT Type DP Test type Slip & Tensile Strength Permanent Elongation & Tensile Strength Static Tension Test Static Compression Test Cyclic Tension & Compression Test Test standards AC 133: 2010: 4.1 BS 8110: PART 1:

More information

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05 Pressure relief valve, pilot-operated Type ZDB and ZDB RE 575 Edition: 06- Replaces: 0.05 Size 6 Component series 4X Maximum operating pressure 35 bar Maximum flow 60 l/min H7746 Features Sandwich plate

More information

HIGH PRESSURE FILTERS

HIGH PRESSURE FILTERS APPLICATION HIGH PRESSURE FILTERS For Manifold Block Side Mounting Series DF...QE Pressures to 4 psi Flows to 18 gpm HYDAC DF...QE High Pressure Filters are designed to be side mounted directly onto the

More information

TECHNICAL CATALOGUE FD/FDM FDM

TECHNICAL CATALOGUE FD/FDM FDM l. ORS TECHNICAL FLOW DIVIDERS DATA FD/FDM MODEL SERIES TECHNICAL CATALOGUE FD FD bar FDM bar FDM INDEX GENERAL INFORMATION rpm - - - 950 - - - - - 950 - - - - - 950 - - - - - 0 - - - - - 0 - - - - - 750

More information

Variable Displacement Plug-In Motor A6VE

Variable Displacement Plug-In Motor A6VE Electric Drives and Controls Hydraulics Linear Motion and Assembly echnologies Pneumatics Service Variable Displacement Plug-In Motor A6VE RE 91 606/06.05 1/16 Replaces: 05.99 echnical data sheet Series

More information

Connections for fluid power and general use Hydraulic couplings for diagnostic purposes. Part 2: Coupling for connection under pressure

Connections for fluid power and general use Hydraulic couplings for diagnostic purposes. Part 2: Coupling for connection under pressure FINAL DRAFT INTERNATIONAL STANDARD ISO/FDIS 15171-2 ISO/TC 131/SC 4 Secretariat: ANSI Voting begins on: 2015-10-20 Voting terminates on: 2015-12-20 Connections for fluid power and general use Hydraulic

More information

SPIN-ON FILTER - LOW PRESSURE LINE

SPIN-ON FILTER - LOW PRESSURE LINE SERIES MSH SPIN-ON FILTER - LOW PRESSURE LINE Maximum working pressure 5 psi Flow rate to 8 GPM D e s c r i p t i o n MSH working pressure of 5 psi, with a peak pressure This filter MSH series utilises

More information

Industrial Mechanic (Millwright) Level 3

Industrial Mechanic (Millwright) Level 3 Industrial Mechanic (Millwright) Level 3 Rev. September 2005 Industrial Mechanic (Millwright) Unit: G5 Prime Movers I Diesel 1 Level: Duration: Three 60 hours Theory: 20 hours Practical: 40 hours Overview:

More information

Hydraulic fluid power Gas-loaded accumulators with separator Selection of preferred hydraulic ports

Hydraulic fluid power Gas-loaded accumulators with separator Selection of preferred hydraulic ports ISO 2017 All rights reserved ISO/TC 131/SC N Date: 2017-08-18 ISO/PDTR 10946 ISO/TC 131/SC /WG 1 Secretariat: AFNOR Hydraulic fluid power Gas-loaded accumulators with separator Selection of preferred hydraulic

More information

Shut-off valves in stainless steel Types SVA-S SS and SVA-L SS

Shut-off valves in stainless steel Types SVA-S SS and SVA-L SS Data sheet Shut-off valves in stainless steel s SVA-S SS and SVA-L SS In certain specific areas such as outdoor applications and corrosive atmospheres, such as coastal installations, there is a need for

More information

High-performance slideway oils for machine tools, with excellent demulsification properties

High-performance slideway oils for machine tools, with excellent demulsification properties CGLP SLIDEWAY OILS High-performance slideway oils for machine tools, with excellent demulsification properties Description The quality of machined components depends heavily on the accurate feed and accurate

More information

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

A complete line of pressure differential visual and electrical indicators are available with this series of filters. D e s c r i p t i o n FHB series filters are designed for pressure line applications where manifold mounting is a specific requirement. The manifold type filters are designed to integrate onto manifold

More information

Tube connection Ambient temperature range Medium temperature range. T min C +80. C T max. max. Weight (mass) kg See table

Tube connection Ambient temperature range Medium temperature range. T min C +80. C T max. max. Weight (mass) kg See table Cylinder Ø32-125 mm with blocking device Series DZB... Blocking reverse stroke Series DZBA... Blocking forward stroke Mountings to ISO 15552 (ISO 6431) Special versions: according to CETOP RP 53 P (Piston

More information

CHAPTER 9 : TYPE II TEST ON SI ENGINES (VERIFYING CARBON MONOXIDE EMISSION AT IDLING)

CHAPTER 9 : TYPE II TEST ON SI ENGINES (VERIFYING CARBON MONOXIDE EMISSION AT IDLING) CHAPTER 9 : TYPE II TEST ON SI ENGINES (VERIFYING CARBON MONOXIDE EMISSION AT IDLING) 1 Scope : This Chapter describes the procedure for the TYPE II test for verifying carbon monoxide emission at idling

More information

3/2 directional spool valve, direct operated with solenoid actuation

3/2 directional spool valve, direct operated with solenoid actuation / directional spool valve, direct operated with solenoid actuation RE 86-4/6. Replaces:.9 / Type KKDE (high-performance) Size Component series A Maximum operating pressure 5 bar Maximum flow 6 l/min H68

More information

ATC ATIEL ACEA CONCAWE. CEC Board

ATC ATIEL ACEA CONCAWE. CEC Board CEC 2010 - Organisation and its Role in Developing Fuels and Lubricant Tests for the European Automotive Industry. UNITI MineralÖl lt Techhnologie Forum 17 th March 2010 The Co-ordinating ordinating European

More information

Guideline No.M-10(201510) M-10 Marine Diesel Engine Fuel Injection Pump

Guideline No.M-10(201510) M-10 Marine Diesel Engine Fuel Injection Pump Guideline No.M-10(201510) M-10 Marine Diesel Engine Fuel Injection Pump Issued date: 20 th October, 2015 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical

More information

introduction FE Series Butterfly Valves Product Data Sheet

introduction FE Series Butterfly Valves Product Data Sheet Product Data Sheet introduction < STANDARDS > ASTM D1784 IPEX FE Series Butterfly Valves incorporate many features of our industrial FK valve, yet the all PVC construction and EPDM liner make this valve

More information

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition: Pressure relief valve, direct operated, with DC motor actuation Type DBGT RE 2943 Edition: 204-02 Size 6 Component series 2X Maximum operating pressure: 700 bar Maximum flow: 2 l/min Features Contents

More information

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request) HYDRAULIC FILTRATION Return filters, tank top mounting, inside-to-outside filtration Technical Information Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to

More information

HOW THE SPRAGUE PRODUCTS BOOSTERS WORK

HOW THE SPRAGUE PRODUCTS BOOSTERS WORK SUPERCHARGE SHOP AIR OR BOTTLED GAS WITH SPRAGUE PRODUCTS GAS BOOSTER Sprague Products pneumatic boosters offer a cost effective way to compress shop air or bottled gas to meet various requirements for

More information

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8. R 26 404/06.9 ccumulator unloading valve, pilot operated, Model D 6 V.., series 4X Size 6 up to 4500 SI (315 bar) up to.00 GM (30 L/min) R 26 404/04.9 Features: For subplate mounting: porting pattern to

More information

FRL unit consist of Filterations, Regulators and Lubricator unit.

FRL unit consist of Filterations, Regulators and Lubricator unit. 4.1 AIR CONTROL 4.1.1 Fluid Conditioner FRL unit consist of Filterations, Regulators and Lubricator unit. It is also known as Air Service Unit. Primary function is to provide clean air at optimal pressure

More information

[TO BE PUBLISHED IN THE GAZETTE OF INDIA, PART-II, SECTION-3, SUB-SECTION (ii)]

[TO BE PUBLISHED IN THE GAZETTE OF INDIA, PART-II, SECTION-3, SUB-SECTION (ii)] [TO BE PUBLISHED IN THE GAZETTE OF INDIA, PART-II, SECTION-3, SUB-SECTION (ii)] Ministry of Consumer Affairs, Food and Public Distribution (Department of Consumer Affairs) BUREAU OF INDIAN STANDARDS New

More information

UV PROCESS SUPPLY, INC.

UV PROCESS SUPPLY, INC. UV PROCESS SUPPLY, INC. GENERAL DESCRIPTION The ¼ Diaphragm Pump others high volume delivery even at low air pressures, easy self-priming, the ability to pump various viscosity materials and the ability

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 1179-1 Second edition 2013-11-01 Connections for general use and fluid power Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing Part 1: Threaded

More information

ISO/TC 131/SC Pneumatic fluid power Cylinders, kpa (10 bar) series Mounting dimensions of rod-end clevises

ISO/TC 131/SC Pneumatic fluid power Cylinders, kpa (10 bar) series Mounting dimensions of rod-end clevises DRAFT INTERNATIONAL STANDARD ISO/DIS 8140 ISO/TC 131/SC 3 Secretariat: DIN Voting begins on: Voting terminates on: 2017-06-07 2017-08-29 Pneumatic fluid power Cylinders, 1 000 kpa (10 bar) series Mounting

More information

Turcon Glyd Ring. Double Acting Rubber Energized Plastic Faced Seal Material: Turcon, Zurcon and Elastomer

Turcon Glyd Ring. Double Acting Rubber Energized Plastic Faced Seal Material: Turcon, Zurcon and Elastomer Turcon Glyd Ring Double Acting Rubber Energized Plastic Faced Seal Material: Turcon, Zurcon and Elastomer 15 Turcon Glyd Ring 16 Turcon Glyd Ring Turcon Glyd Ring Description Successfully used for decades,

More information

Valve Technology and Special Solutions for Transmissions on Mobile Machines

Valve Technology and Special Solutions for Transmissions on Mobile Machines Valve Technology and Special Solutions for Transmissions on Mobile Machines Your partner for expertise in solutions specific to mobile transmissions Innovative and tailored valve solutions for modern mobile

More information

Input, Control and Processing elements

Input, Control and Processing elements PNEUMATIC & HYDRAULIC SYSTEMS CHAPTER FIVE Input, Control and Processing elements Dr. Ibrahim Naimi Valves The function of valves is to control the fluid path or the pressure or the flow rate. Depending

More information

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J 1 IMPORTANT: READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING. PUMP DATA TYPE: MAT'L: WEIGHT: Air Operated Double Diaphragm Polypropylene or PVDF or Acetal PVDF (Polyvinylidene Fluoride)

More information

DK Series Pneumatic Diaphragm Valves Product Data Sheet

DK Series Pneumatic Diaphragm Valves Product Data Sheet 1" through 2-1/2" 1/2" and 3/4" < STANDARDS > ASTM D1784 ASTM D1785 ASTM D4101 ASTM D3222 ASTM D2464 ASTM D2466 ASTM D2467 ASTM F441 ASTM F437 ASTM F439 ASTM F1498 IPEX DK Series are the ideal solution

More information

Directional servo-valve in 4-way design

Directional servo-valve in 4-way design Directional servo-valve in 4-way design RE 2983/.11 Replaces: 7.3 1/ Type 4WS.2E... Size Component series X Maximum operating pressure 31 bar Maximum flow 1 l/min HD892 Type 4WSE2ED -X/...K31EV HD893 Type

More information

Industry. Contents. Flender Foaming Test GG-V 425 Rev.1 Description of the testing instrument; carrying out the test; criteria

Industry. Contents. Flender Foaming Test GG-V 425 Rev.1 Description of the testing instrument; carrying out the test; criteria Contents 1 Introduction...3 2 Description of the testing instrument...3 3 Carrying out the test...6 4 Evaluation and assessment of the foaming characteristics...7 5 Literature...7 6 Enclosures...7 _ Page

More information

Synthetic EP air compressor oils based on PAO, for turbo, screw, vane and piston compressors; High-performance synthetic, PAO-based hydraulic fluids

Synthetic EP air compressor oils based on PAO, for turbo, screw, vane and piston compressors; High-performance synthetic, PAO-based hydraulic fluids Description Compressed air has become a major form of energy and the reliable generation of compressed air is vital. Operators require compressors to function perfectly over and beyond entire service intervals.

More information

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL 14 201/118 ED RV1P VARIABLE DISPLACEMENT VANE PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS (measured with mineral oil with viscosity of 46 cst at 40 C) RV1P are variable displacement vane pumps with

More information

Air Driven Gas Boosters

Air Driven Gas Boosters Features & Benefits Sprague Products pneumatic boosters offer a cost effective way to compress shop air or bottled gas to meet various requirements for higher pressure, lower volume air or gas. Industrial

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 15524 First edition 2011-11-01 Pneumatic fluid power Cylinders Single-rod short-stroke cylinders, 1 000 kpa (10 bar) series, bores from 20 mm to 100 mm Transmissions pneumatiques

More information