Model A Switching Logic Board. User s Manual. For Use With Minarik Full-Wave Regenerative Drives
|
|
- Shanon Dickerson
- 5 years ago
- Views:
Transcription
1 Model A Switching Logic Board User s Manual For Use With Minarik Full-Wave Regenerative Drives
2 Copyright 2002 by Minarik Corporation All rights reserved. No part of this manual may be reproduced or transmitted in any form without written permission from Minarik Corporation. The information and technical data in this manual are subject to change without notice. Minarik Corporation and its Divisions make no warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. Minarik Corporation and its Divisions assume no responsibility for any errors that may appear in this manual and make no commitment to update or keep current the information in this manual. MVD Printed in the United States of America.
3 Safety Warnings SHOCK HAZARD AVOID HEAT KEE DR OID ATION Have a qualified electrical maintenance technician install, adjust, and service this equipment. Follow the National Electrical Code and all other applicable electrical and safety codes, including the provisions of the Occupational Safety and Health Act (OSHA) when installing equipment. Reduce the chance of an electrical fire, shock, or explosion by proper grounding, over current protection, thermal protection, and enclosure. Follow sound maintenance procedures. It is possible for a drive to run at full speed as a result of a component failure. Install a master switch in the AC line for stopping the drive in an emergency. When the switching logic board is connected to a variable speed regenerative drive it is isolated from earth ground. Circuit potentials are at 115 VAC or 230 VAC above earth ground. Avoid direct contact with the printed circuit board or with circuit elements to prevent the risk of serious injury or fatality. Use a non-metallic screwdriver for any necessary adjustments.
4 ii Contents Safety Warnings i Specifications 1 Dimensions 2 General Information 3 Installation 4 Mounting the Logic Board Wiring Screw terminal block Speed adjust potentiometer Shielding Guidelines Modes of Operation 10 Pushbutton switches Limit switches Foot pedals DIP switches Pushbutton operation: FORWARD/STOP/REVERSE Pushbutton operation: RUN/STOP Pushbutton operation: jog FORWARD/jog REVERSE Pushbutton operation: jog RUN Limit switch operation: no automatic reversing Limit switch operation: FORWARD/STOP/REVERSE, 1 Cycle Limit switch operation: automatic cycling Foot pedal operation: FORWARD/STOP/REVERSE Foot pedal operation: RUN/STOP
5 iii Connection to Minarik Regenerative Drives 22 Unconditional Warranty inside back cover Illustrations Figure 1. Model A Switching Logic Board Layout and Dimensions 2 Figure 2. Screw Terminal Block 5 Figure 3. Speed Adjust Potentiometer 6 Figure 4. Single Speed Potentiometer Connections 7 Figure 5. Two Speed Potentiometer Connection 8 Figure 6. Pushbutton Operation: FWD/STOP/REV 12 Figure 7. Pushbutton Operation: RUN/STOP 13 Figure 8. Pushbutton Operation: jog Forward/jog Reverse 14 Figure 9. Pushbutton Operation: jog RUN 15 Figure 10. Limit switch operation: no automatic reversing 16 Figure 11. Limit Switch Operation: FWD/STOP/REV, 1 cycle 17 Figure 12. Limit Switch Operation: automatic cycling 19 Figure 13. Foot pedal operation: FORWARD/STOP/REVERSE 20 Figure 14 Foot pedal operation: RUN/STOP 21 Figure 15. Connection diagram: Switching Logic Board ( A) to RG100UC/RG200UC 22 Figure 16. Connection diagram: Switching Logic Board ( A) to RG300UA/RG310UA/RG400UA 23 Figure 17. Connection diagram: Switching Logic Board ( A) to RG500UA/RG510UA 24
6 iv Illustrations (cont.) Figure 18. Connection diagram: Switching Logic Board ( A) to RG5500U 25 Figure 19. Connection diagram: Switching Logic Board ( A) to MRG30U/MMRG31U/MMRG40U 26 Figure 20. Connection diagram: Switching Logic Board ( A) to MMRGD03/MMRGD10 27 Figure 21. Connection diagram: Switching Logic Board ( A) to RG60U 28 Figure 22. TTL Logic Input 29 Figure 23. NPN Open Collector Input 30 Figure 24. Contact Input 31
7 1 Specifications Input Power ma ma Acceptable Input Devices Dry Contacts Current-Sinking Open Collectors TTL Logic Devices Number of Switching Modes Four (4) Speed adjust potentiometer 10 K Ohms Maximum Reference Voltage to Drive ±15 VDC Ambient Operating Temperature Range 10 C - 40 C Weight 0.2 lbs Note: This switching logic board is specifically designed to operate with Minarik control models RG100UC, RG200UC, RG300U, RG400U, RG500U, RG5500U, and RG60U. Consult factory before attempting to use with other models.
8 2 Dimensions TB502 TB POWER IL501 6 IC501 7 K501 IC [79] K [5] 0.87 [22] 2.49 [63] 3.45 [88] MOUNTING HOLES 0.19 [5] - 4 PLACES " Figure 1. Model A Switching Logic Board Layout and Dimensions
9 3 General Information Caution Regenerative braking imposes very high stress on the rotating components of the drive train. It is very important that these deceleration forces be considered before selecting a drive system that applies regenerative braking to a gearmotor or other gearbox. Minarik Corporation s model A provides the logic interface between the regenerative drive and pushbutton stations, foot switches, or programmable controls. It accepts dry contact mechanical closures, current-sinking open collectors, and TTL logic devices. The limit switch logic board has four operating modes, which can be configured nine different ways. Select the one that fits your application and follow the wiring and DIP switch instructions for that configuration. The speed adjust potentiometer (10K ohms, 2 watts) is wired through the logic board ( A) module, rather than directly to the regenerative drive. Use either one potentiometer for both forward and reverse speeds (Figure 4, page 7) or if different speeds are required in each direction one potentiometer for forward and one potentiometer for reverse speed settings (Figure 5, page 8).
10 4 Installation Mounting the Logic Board Logic board components are sensitive to electrostatic fields. Avoid contact with the circuit board directly. Protect the logic board from dirt, moisture, and accidental contact. Provide sufficient room for access to the terminal block. Mount the logic board away from other heat sources. Operate within the specified ambient operating temperature range. The operating temperature range for the A is 10 C through 40 C. Prevent loose connections by avoiding excessive vibration of the logic board. Mount the logic board in either a horizontal or vertical plane using the four 0.19 inch [5 mm] mounting holes located on the board.
11 Installation 5 Wiring Screw terminal block Connections to Minarik s A logic board are made to a screw terminal block. There are two screw terminal blocks on the board. The large one is shown in Figure 2. The smaller screw terminal block has a similar connection style to the one shown. Using a screwdriver, turn the terminal block screw counterclockwise to open the wire clamp. Insert stripped wire into the wire clamp. Turn the terminal block screw clockwise to clamp the wire. TERMINAL BLOCK SCREW WIRE CLAMP Figure 2. Screw Terminal Block
12 6 Installation Speed adjust potentiometer Warning Be sure that the potentiometer tabs do not make contact with the potentiometer enclosure. Grounding the input will cause damage to the regenerative drive. Install the circular insulating disk between the panel and the 10K ohm speed adjust pot. Mount the speed adjust pot through a 0.38 inch (10mm) hole with the hardware provided (Figure 3). Twist the speed adjust pot wire to avoid picking up unwanted electrical noise. If potentiometer leads are longer than 18 inch (457mm), use shielded cable. Logic lines of this length act as an antenna and can pick up noise from the drive components, noise from other devices or other ground wires, or voltage from power lines that can cause erratic operation. The A does not include this pot. MOUNT THROUGH A 0.38 IN. (10 MM) HOLE CW WIPER W NUT STAR WASHER SPEED ADJUST POTENTIOMETER PANEL INSULATING DISK Figure 3. Speed Adjust Potentiometer
13 Installation 7 It may be necessary to earth ground the shielded cable. If noise is produced by devices other that the drive, ground the shield at the drive end. If noise is generated by a device on the drive, ground the shield at the end away from the drive. Do not ground both ends of the shield. The following diagrams show the potentiometer connections to terminal block 2 (TB2). Use Figure 4 when a single speed is desired in both the forward and reverse directions. Use Figure 5 when one speed is desired in the forward direction, and a different speed is desired in the reverse direction CW 10K OHM SPEED ADJUST POTENTIOMETER Figure 4. Single Speed Potentiometer Connections
14 8 Installation CW CW Figure 5. Two Speed Potentiometer Connection
15 Installation 9 Shielding Guidelines Warning Under no circumstances should power and logic leads be bundled together. Induced voltage can cause unpredicatble behavior in any electronic device, including motor controls. As a general rule, Minarik recommends shielding of all conductors. If it is not practical to shield power conductors, Minarik recommends shielding all logic-level leads. If shielding logic leads is not practical, the user should twist all logic leads with themselves to minimize induced noise. It may be necessary to earth ground the shielded cable. If noise is produced by devices other than the drive, ground the shielf at the drive end. If noise is generated by a device on the drive, ground the sheild at the end away from the drive. Do not ground both ends of the shield. If the drive continues to pick up noise after grounding the shield, it may be necessary to add AC line filtering devices, or to mount the drive in a less noisy environment.
16 10 Modes of Operation The limit switch logic board has four (4) different modes of operation which can be configured into nine (9) difference connections. They are as follows: 1) FORWARD/STOP/REVERSE Pushbutton Operation Limit Switch Operation Foot Pedal Operation 2) RUN/STOP Pushbutton Operation Foot Pedal Operation Limit Switch Operation (no automatic reversing) 3) jog FORWARD/jog REVERSE Pushbutton Operation 4) jog RUN Pushbutton Operation Limit Switch Operation
17 Modes of Operation 11 Pushbutton switches Pushbutton switches are momentary operated type. RUN, FWD, and REV switches are normally open. STOP switches are normally closed. Limit switches Limit switches are single pole, single throw, normally closed. Foot pedals Foot pedals are single pole, single throw, normally open. DIP switches Use a small screwdriver to change DIP switch settings. The arrow on the dip switch box indicates the ON position.
18 12 Modes of Operation Pushbutton operation: FORWARD/STOP/REVERSE In this mode the appropriate pushbutton initiates travel. The motor is reversed by pressing the opposite direction pushbutton. The stop pushbutton will regeneratively brake the motor. OFF OFF O N TB501 FWD REV STOP JUMPER Figure 6. Pushbutton Operation: FWD/STOP/REV
19 Modes of Operation 13 Pushbutton operation: RUN/STOP In this mode the RUN pushbutton is actuated to start the motor. The motor will continue to run until the STOP pushbutton is depressed. This mode does not allow reversing. If the motor runs in the wrong direction, shut down the system and reverse the armature connections to the regenerative drive. OFF OFF O N TB501 RUN STOP JUMPER Figure 7. Pushbutton Operation: RUN/STOP
20 14 Modes of Operation Pushbutton operation: jog FORWARD/jog REVERSE In this mode the motor turns only when the forward or reverse pushbutton is being depressed. To reverse the motor, first release the activated pushbutton to regeneratively brake the motor. Then push the opposite direction pushbutton. ON ON O N TB501 FWD REV JUMPER JUMPER Figure 8. Pushbutton Operation: jog Forward/jog Reverse
21 Modes of Operation 15 Pushbutton operation: jog RUN In this mode the motor turns only as long as the RUN pushbutton is depressed. When the pushbutton is released the drive will regeneratively brake the motor. If the motor runs in the wrong direction, shut down the system and reverse the armature connections to the regenerative drive. ON ON O N TB501 RUN JUMPER JUMPER Figure 9. Pushbutton Operation: jog RUN
22 16 Modes of Operation Limit switch operation: no automatic reversing In this mode activating the appropriate pushbutton will initiate travel. The motor will regeneratively brake when the corresponding limit switch is actuated (opened) or when the STOP pushbutton is depressed. If travel is interrupted by STOP before the limit switch is reached, it can be resumed by pressing the appropriate direction pushbutton. OFF OFF O N TB501 REV FWD REV STOP FWD Figure 10. Limit switch operation: no automatic reversing
23 Modes of Operation 17 Limit switch operation: FORWARD/STOP/REVERSE, 1 Cycle In this single-cycle mode the motor automatically returns to the REV limit switch location. It normally begins at that site with the actuation of the FWD pushbutton. If the starting position is not at the FWD limit switch, press FWD to complete the balance of the automatic FWD/STOP/REV cycle or press REV to complete the REV portion of the cycle. ON OFF O N TB501 REV FWD REV STOP FWD Figure 11. Limit Switch Operation: FWD/STOP/REV, 1 cycle
24 18 Modes of Operation Limit switch operation: automatic cycling In this mode the motor will continuously cycle the load between the FWD and REV limit switches. To stop the cycling process, press the STOP pushbutton. Re-starting the cycle is dependent upon the position of the machine when stopped: If stopping occurs with the FWD limit switch activated, the REV pushbutton must be pressed to re-start. If stopping occurs with the REV limit switch activated, the FWD pushbutton must be pressed to re-start the cycle. If stopping occurs between the FWD and REV limit switches, either pushbutton may be pressed to re-start the cycle.
25 Modes of Operation 19 OFF ON O N TB501 REV FWD REV STOP FWD Figure 12. Limit Switch Operation: automatic cycling
26 20 Modes of Operation Foot pedal operation: FORWARD/STOP/REVERSE In this mode the motor runs as long as a pedal is depressed. When the pedal is released the drive will regeneratively brake the motor. When reversing the direction of travel it is necessary to release one pedal before depressing the other. ON ON O N TB501 FWD REV JUMPER JUMPER Figure 13. Foot pedal operation: FORWARD/STOP/REVERSE
27 Modes of Operation 21 Foot pedal operation: RUN/STOP In this mode the motor runs as long as the pedal is depressed. Release the pedal and the drive will regeneratively brake the motor. If the motor runs in the wrong direction, shut down the system and reverse the armature connections to the regenerative drive. ON ON O N TB501 RUN JUMPER JUMPER Figure 14 Foot pedal operation: RUN/STOP
28 22 Connection to Minarik Regenerative Drives K501 K502 IC P501 K501 P502 P509 C501 P503 P510 IC501 C502 P504 IC502 TB A RG100UC/RG200UC Figure 15. Connection diagram: Switching Logic Board ( A) to RG100UC/RG200UC
29 Connection to Minarik Regenerative Drives GND F1 T505 F2 A2 K502 IC502 C504 C502 C503 TB501 A1 2 1 C511 IC502 IC501 C505 + INHIBIT + TB S3 S2 S1 S0 RB1 RB A RG300UA/RG310UA/ RG400UA Figure 16. Connection diagram: Switching Logic Board ( A) to RG300UA/RG310UA/RG400UA
30 24 Connection to Minarik Regenerative Drives A RG500UA/RG510UA TB502 C S3 S2 S1 S0 RB1 RB T1 T2 Figure 17. Connection diagram: Switching Logic Board ( A) to RG500UA/RG510UA
31 Connection to Minarik Regenerative Drives A RG5500U A2 A1 DISABLE/ENABLE CFVS SW505 TB502 C503 C516 IC TB501 L1 L2 CS S3 S2 S1 SO TP -15 S1 S2 S3 S0 Figure 18. Connection diagram: Switching Logic Board ( A) to RG5500U
32 26 Connections to Minarik Regenerative Drives A MMRG30U/MMRG31U/ MMRG40U S DS5 1 K HZ PL K DC VOLTAGE DC VOLTAGE S SW501 MMRG PL1 12 DC VOLTAGE 10 TB502 DC VOLTAGE +15V -15V T501 SO501 COMMON S0 IC501 Figure 19. Connection diagram: Switching Logic Board ( A) to MRG30U/MMRG31U/MMRG40U
33 Connections to Minarik Regenerative Drives A MMRGD03/MMRGD10 POWER S0 IL503 IL504 IL505 IC501 K502 K C502 C501 SW502 IC502 SW P501 P502 P503 P504 SW503 T501 S1 REV FWD S2 S3 +15V -15V RB4 RB3 RB2 RB1/COM TACHO FEEDBACK TACH ARM SO501 IC501 PL2 ARMATUR TB502 FWD ACC REV ACC FWD TQ REV TQ P508 P507 P506 P505 MAX MIN IR SPD SPD COMP TACH Figure 20. Connection diagram: Switching Logic Board ( A) to MMRGD03/MMRGD10
34 K 28 Connections to Minarik Regenerative Drives REV C50 IC502 L2 L1 X INVERT INHIBIT MP INVERT ENABLE LIMIT FWD REV D IL501 IL502 TB502 Y501 JP502 C503 IC501 IC504 TB503 ENABLE C5 IL503 K501 POWER TACH T2 T1 RB1 RB2-15V +15V S3 S2 S1 S TB501 T501 S3 S2 S1 S A RG60U Figure 21. Connection diagram: Switching Logic Board ( A) to RG60U
35 TB502 NOTE: TTL GATES MAY REQUIRE PULL-UP RESISTORS FWD PB N.O. REV PB N.O. TTL GATES STOP PB N.C. COMMON FWD LS N.C. REV LS N.C. TTL LOGIC +5 R 2.2K TB A SWITCHING LOGIC BOARD TB Figure 22. TTL Logic Input 9 8 (RB1/COM) (+15) (S2) (-15) JUMPER REV CW FWD CW INDEPENDENT FWD & REV SPEED CONNECTIONS SHOWN CAUTION! TTL LOGIC MUST BE ISOLATED FROM THE AC LINE. CW JUMPERS SINGLE SPEED FOR FWD & REV CONNECTIONS SHOWN Connections to Minarik Regenerative Drives 29
36 TB BASE CURRENT LIMITING RESISTORS FWD PB R N.O. +BASE VOLTAGE REV PB R N.O. +BASE VOLTAGE STOP PB R N.C. +BASE VOLTAGE COMMON FWD LS N.C. REV LS N.C. TB A SWITCHING LOGIC BOARD TB (RB1/COM) (+15) (S2) (-15) JUMPER REV CW FWD CW INDEPENDENT FWD & REV SPEED CONNECTIONS SHOWN CW JUMPERS SINGLE SPEED FOR FWD & REV CONNECTIONS SHOWN Connections to Minarik Regenerative Drives CAUTION! NPN TRANSISTOR SUPPLY VOLTAGE MUST BE ISOLATED FROM THE AC LINE. Figure 23. NPN Open Collector Input
37 TB502 FWD PB N.O. REV PB N.O. STOP PB N.C. FWD LS N.C. REV LS N.C. TB A SWITCHING LOGIC BOARD TB (RB1/COM) (+15) (S2) (-15) JUMPER REV CW FWD CW INDEPENDENT FWD & REV SPEED CONNECTIONS SHOWN CW JUMPERS SINGLE SPEED FOR FWD & REV CONNECTIONS SHOWN Connections to Minarik Regenerative Drives Figure 24. Contact Input 31
38 32 NOTES
39 Unconditional Warranty A. Warranty Minarik Corporation (referred to as "the Corporation") warrants that its products will be free from defects in workmanship and material for twelve (12) months or 3,000 hours, whichever comes first, from date of manufacture thereof. Within this warranty period, the Corporation will repair or replace, at its sole discretion, such products that are returned to Minarik Corporation, 901 East Thompson Avenue, Glendale, CA USA. This warranty applies only to standard catalog products, and does not apply to specials. Any returns for special controls will be evaluated on a case-by-case basis. The Corporation is not responsible for removal, installation, or any other incidental expenses incurred in shipping the product to and from the repair point. B. Disclaimer The provisions of Paragraph A are the Corporation's sole obligation and exclude all other warranties of merchantability for use, express or implied. The Corporation further disclaims any responsibility whatsoever to the customer or to any other person for injury to the person or damage or loss of property of value caused by any product that has been subject to misuse, negligence, or accident, or misapplied or modified by unauthorized persons or improperly installed. C. Limitations of Liability In the event of any claim for breach of any of the Corporation's obligations, whether express or implied, and particularly of any other claim or breech of warranty contained in Paragraph A, or of any other warranties, express or implied, or claim of liability that might, despite Paragraph B, be decided against the Corporation by lawful authority, the Corporation shall under no circumstances be liable for any consequential damages, losses, or expense arising in connection with the use of, or inability to use, the Corporation's product for any purpose whatsoever. An adjustment made under warranty does not void the warranty, nor does it imply an extension of the original 12-month warranty period. Products serviced and/or parts replaced on a no-charge basis during the warranty period carry the unexpired portion of the original warranty only. If for any reason any of the foregoing provisions shall be ineffective, the Corporation's liability for damages arising out of its manufacture or sale of equipment, or use thereof, whether such liability is based on warranty, contract, negligence, strict liability in tort, or otherwise, shall not in any event exceed the full purchase price of such equipment. Any action against the Corporation based upon any liability or obligation arising hereunder or under any law applicable to the sale of equipment or the use thereof, must be commenced within one year after the cause of such action arises.
40 901 East Thompson Avenue Glendale, California Phone: (818) Fax: (818) Document number , Revision 2 Printed in the U.S.A June 2002
C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL
C1XP Series Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL Copyright 2013 by Minarik Drives All rights reserved. No part of this document may be reproduced or transmitted in any form without
More informationMM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors
MM501U User s Manual SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors Copyright 2002 by Minarik Corporation All rights reserved. No part of this manual may be reproduced or transmitted in
More informationSCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL
SPEEDMASTER SCR THYRISTOR MOTOR CONTROLS Catalog Numbers 174100, 174105, 174307, 174308, 174311, 174709, M1740005, M1740006, M1740007 OPERATION MANUAL LIMITED WARRANTY A. Warranty - Leeson Electric Corporation
More informationAn American Control Electronics Brand. RG6xU SERIES USER MANUAL RG60U RG61U.
An American Control Electronics Brand RG6xU SERIES USER MANUAL RG60U RG61U www.minarikdrives.com Dear Valued Consumer: Congratulations on your purchase of the RG6xU Series drive. This User Manual was created
More informationSPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS
SPEEDMASTER Operation Manual 174102 & 174107 NEMA 4X SCR MOTOR CONTROLS LIMITED WARRANTY A. Warranty - LEESON Electric warrants that its products will be free from defects in material and workmanship for
More informationXP Series USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC.
An American Control Electronics Brand USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC www.minarikdrives.com Dear Valued Consumer: Congratulations on
More informationMM03-PCM MM10-PCM. User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors
MM03-PCM MM10-PCM User s Manual SCR, Adjustable Speed Drives for DC Brush Motors Copyright 2002 by Minarik Corporation All rights reserved. No part of this manual may be reproduced or transmitted in any
More informationModels: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors
Models: 170-203-0002 170-203-0005 User s Manual Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors Copyright 2006 by Bison Gear & Engineering All rights reserved. No part of this manual
More informationAn American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.
An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A www.minarikdrives.com Dear Valued Consumer: Congratulations on your purchase of the
More informationPWP Series USER MANUAL PWP100-2 PWP100-2-QDT PWP100-5 PWP PWP101-2 PWP101-5 PWP
USER MANUAL PWP100-2 PWP100-2-QDT PWP100-5 PWP100-10 PWP101-2 PWP101-5 PWP101-10 www.americancontrolelectronics.com Dear Valued Consumer: Congratulations on your purchase of the PWP Series drive. This
More information17429X.00 SERIES MODELS:
LEESON ELECTRIC MOTORS, GEARMOTORS AND DRIVES R User s Manual 17429X.00 SERIES MODELS: 174298.00 174299.00 PWM REGENERATIVE DC TO DC DRIVES II Table of Contents 17429X.00 Drives...............................................................
More informationMM23xx1C Series USER MANUAL MM23001C MM23001C-Q MM23011C MM23011C-Q MM23101C MM23111C MM23201C MM23211C MM23401C MM23411C.
USER MANUAL MM23001C MM23001C-Q MM23011C MM23011C-Q MM23101C MM23111C MM23201C MM23211C MM23401C MM23411C An American Control Electronics Brand www.minarikdrives.com Dear Valued Consumer: Congratulations
More informationExcel [XL] Series USER S MANUAL
Excel [XL] Series USER S MANUAL MODELS C4XL3025 C4XL3200A Pulse-Width Modulated, Adjustable Speed, Cased Drives for DC Brush Motors Copyright 2006 by Minarik Drives All rights reserved. No part of this
More informationUSER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM
N R G - 4 Q S e r i e s USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM Four Quadrant, Regenerative PWM Drives For DC Brush
More informationDO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.
Safety Warnings i This symbol denotes an important safety tip or warning. Please read these instructions carefully before performing any of the procedures contained in this manual. DO NOT INSTALL, REMOVE,
More informationMDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA
MDC150-012301 12V, 30A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471
More informationUSER S MANUAL. Variable-frequency drives for 3-phase and single-phase AC motors
USER S MANUAL Variable-frequency drives for 3-phase and single-phase AC motors 175318 175318PCM 175319 175319PCM 175320 175321PCM 175321 175321PCM 175310 175310PCM 175322 175322PCM 175323 175323PCM 175311
More informationVFD Series USER MANUAL VFD02-115AC VFD02-230AC VFD02-D230AC VFD04-115AC VFD04-230AC VFD04-D230AC.
USER MANUAL VFD02-115AC VFD02-230AC VFD02-D230AC VFD04-115AC VFD04-230AC VFD04-D230AC www.minarikdrives.com Dear Valued Consumer: Congratulations on your purchase of the VFD Series drive. This User Manual
More informationRG500 SERIES USER S MANUAL. SCR, Dual Voltage, Adjustable-Speed Regenerative Drives for DC Brush Motors
RG500 SERIES USER S MANUAL SCR, Dual Voltage, Adjustable-Speed Regenerative Drives for DC Brush Motors Copyright 2001 by Minarik Corporation All rights reserved. No part of this manual may be reproduced
More informationMDCSL V, 30A
MDCSL100-050301 50V, 30A Sensorless Controller User s Guide A N A H E I M 4985 E. Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com A U T O M A T I O N (714) 992-6990 fax: (714) 992-0471
More informationMDC Series
MDC151-012601 Series 12V @ 60A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax:
More informationMHS Series USER MANUAL MHS MHS MHS MHS443-10
USER MANUAL MHS403-1.5 MHS403-10 MHS403-25 MHS443-10 Dear Valued Consumer: Congratulations on your purchase of the MHS Series drive. This User Manual was created for you to get the most out of your new
More informationMDC VAC Input Brushless Controller. User s Guide E. Landon Drive Anaheim, CA
MDC2-2451 11VAC Input Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 9287 e-mail: info@anaheimautomation.com (714) 992-699 fax: (714) 992-471 website:
More informationBoston Gear Ratiotrol DC Motor Speed Control
Boston Gear Ratiotrol DC Motor Speed Control P-3017-BG Doc. No. 60007 Installation and Operation DCX plus Series II Enclosed Models 1/12-1 HP a division of Altra Industrial Motion Contents l General Information
More informationBSC Series
BSC151-024031 Series 24V, 3A Brushless Speed Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax:
More informationBLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA
BLDPN30001 Series 30A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471
More informationMDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA
MDCKB1-120081 120VAC, 8A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471
More informationBLY34MDA Series. 50V, 30A Brushless Controller / Motor. User s Guide E Landon Drive, Anaheim, CA
BLY34MDA Series 50V, 30A Brushless Controller / Motor User s Guide A N A H E I M A U T O M A T I O N 4985 E Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)
More informationGS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual
GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS User s Manual Safety Warnings SHOCK HAZARD AVOID HEAT KEEP DRY AVOID VIBRATION This symbol denotes an important safety tip or warning. Please
More informationMDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA
MDCKB1-120081-01 110VAC, 8A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471
More informationMDC Series
MDC050-050051 Series 50V, 5A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)
More informationMDC Series
MDC151-050101 Series 50V, 10A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)
More informationInstallation and Operating Manual
MOTORS AND DRIVES SIGNAL ISOLATOR Accessory for BC204 Regenerative Drive Installation and Operating Manual 4/2000 MN1387 TABLE OF CONTENTS Section Page i. Safety Warning..........................................................
More informationUSER S MANUAL
USER S MANUAL 170-503-0002 Variable-frequency drives for 3-phase and single-phase AC motors Copyright 2006 by Bison Gear & Engineering All rights reserved. No part of this manual may be reproduced or transmitted
More informationMDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA
MDC150-120151 120VAC, 15A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471
More informationBLWS23MDAxS-160 Offline Series 110VAC, 3A Brushless Controller / Motor
BLWS23MDAxS-160 Offline Series 110VAC, 3A Brushless Controller / Motor User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990
More informationUSER S MANUAL VFD SERIES. Variable-frequency drives for 3-phase and single-phase AC motors
USER S MANUAL VFD SERIES Variable-frequency drives for 3-phase and single-phase AC motors VFD01-230AC VFD01-D230AC VFD02-115AC VFD02-230AC VFD02-D230AC VFD04-115AC VFD04-230AC VFD04-D230AC VFD01-230AC-PCM
More informationUSER S MANUAL VFD05-D230-PCM VFDP4X04-D230-PCM VFDA4X04-D230-PCM VFDF4X04-D230-PCM VFDS4X05-D230-PCM
USER S MANUAL VFD PCM SERIES Variable-frequency drives for 3-phase and single-phase AC motors VFD05-D230-PCM VFDP4X04-D230-PCM VFDA4X04-D230-PCM VFDF4X04-D230-PCM VFDS4X05-D230-PCM Copyright 2005 by Minarik
More informationDC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC
DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC Instruction Manual D2-3453 The information in this manual is subject to change without notice. Throughout this manual, the following notes
More informationUser s Manual. SCR, Adjustable Speed Drives for DC Brush Motors
MM23000 Series User s Manual SCR, Adjustable Speed Drives for DC Brush Motors Copyright 2001 by Minarik Corporation All rights reserved. No part of this manual may be reproduced or transmitted in any form
More informationMBDC V, 30A Brush Controller. User s Guide E. Landon Drive Anaheim, CA
MBDC050-050301 50V, 30A Brush Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website:
More informationMBDC V, 10A Brush Controller. User s Guide East Landon Drive, Anaheim, CA
MBDC050-050101 50V, 10A Brush Controller User s Guide A N A H E I M A U T O M A T I O N 4985 East Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website:
More informationBoston Gear Ratiotrol DC Motor Speed Control
Boston Gear Ratiotrol DC Motor Control P-25-BG Installation and Operation Doc. No. 1 DCX Series ll Chassis Models 1/12 - HP a division of Altra Industrial Motion Contents Operating Conditions l II III
More informationCBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls
CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls P-269-89-0408 Installation Installation & Operating Instructions Contents Introduction........................... 2 Specifications.........................
More informationMBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA
MBDC050-024031-120V 110VAC Input Brush DC Controller User s Guide A N A H E I M A U T O M A T I O N 4985 East Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)
More informationMDC Series
MDC300-120151 Series 120VAC, 15A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)
More informationBLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide E. Landon Drive Anaheim, CA
BLWR23MDA Series 24V, 15A Brushless Controller / Motor User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)
More informationUSER S MANUAL. Variable-frequency drive for 3-phase and single-phase AC motors
USER S MANUAL Variable-frequency drive for 3-phase and single-phase AC motors 170-543-0004 Copyright 2006 by Bison Gear & Engineering All rights reserved. No part of this manual may be reproduced or transmitted
More informationSAFTRONICS DF8 PLUS SERIES
DF8 PLUS SERIES ¼ to 5 HP Full Wave Regenerative Reversing SCR Speed Controls for DC Motors CAUTION Equipment is at possibly lethal AC line voltage when AC power is connected. Pressing the STOP pushbutton
More informationFiltered PWM Speed Control for Permanent Magnet DC Motors
Instructions for Installation and Operation Filtered PWM Speed Control for Permanent Magnet DC Motors Model 0794 Speed and Direction Control up to 5/8 HP NEMA-1/IP-20 Specifications Product Type:... WPM-2148E1
More informationUSER'S MANUAL MODEL DPS32PG1 DRIVER PACK
USER'S MANUAL MODEL DPS32PG1 DRIVER PACK ANAHEIM AUTOMATION 4985 E. Landon Drive Anaheim, CA 92807 Phone: (714) 992-6990 Fax: (714) 992-0471 http://www.anaheimautomation.com Email: info@anaheimautomation.com
More informationCBC-802 Plug-In Clutch/Brake Control with Solid State Switching
DIST. AUTORIZADO Plug-In Clutch/Brake Control with Solid State Switching P-29-5 19-0409 Service & Installation Instructions An Altra Industrial Motion Company DIST. AUTORIZADO Brake (Red) and clutch (Green)
More informationGraham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual
Graham TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Vari Speed S1000 Instruction Manual TABLE OF CONTENTS Introduction 4 Unit Features 5 Operating Conditions 6 Specifications 7 Ratings
More informationDC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455
DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC Instruction Manual D2-3455 The information in this manual is subject to change without notice. Throughout this manual, the following
More informationBLY17MDA Series. 24V, 10A Brushless Controller/Motor. User s Guide E. Landon Drive Anaheim, CA
BLY17MDA Series 24V, 10A Brushless Controller/Motor User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471
More informationINSTALLATION & OWNER'S MANUAL
INSTALLATION & OWNER'S MANUAL THE EAGLE POWER I BATTERY BACK UP PHONE (818) 764-6690 / TOLL FREE (800) 708-8848 PRE INSTALLATION INSTRUCTIONS BEFORE PROCEEDING WITH INSTALLATION READ THIS MANUAL THOROUGHLY
More information2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /
Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.
More informationDPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA
DPD72001, DPD72002 Unipolar Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471
More informationDPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:
DPBHV001, DPZHV002 High Voltage Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)
More informationMBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA
MBD45021-75 Enhanced Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website:
More informationBoston Gear Ratiotrol
Boston Gear Ratiotrol DC Motor Speed Control P-05-BG Doc. No. 85 Installation and Operation RP, RPR /6-/ HP RP, RPR /4- HP a division of Altra Industrial Motion GENERAL INFORMATION Description Boston Gear
More informationTM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060
TM4500 Track Mounted Step Motor Driver User s Guide CE Certified and RoHS Compliant A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990
More informationCBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls
CBC-300 & CBC-300- Series Dual Channel Adjust Clutch/Brake Controls P-205-WE 89-0549 Installation & Operating Instructions An Altra Industrial Motion Company Contents Introduction... 2 Specifications...
More informationGC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY
GC-1 Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GENERAL INFORMATION The GC-1 heating cable controller has been designed and manufactured for
More informationDC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI
250-0287-rev2.qxd 3/12/01 10:27 AM Page a DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D-00-010-AI M/N DC3N-12D-4X-010-AI Instruction Manual D2-3452-1 250-0287-rev2.qxd
More informationFincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible
DC Drives Flexible & Powerful single-phase DC drives provide a complete family solution from the compact Series 2120 chassis drive to the powerful Series 2230 and it s feature rich application specific
More informationCBC-802 Plug-In Clutch/Brake Control with Solid State Switching
CBC-02 Plug-In Clutch/Brake Control with Solid State Switching P-2104-WE 19-054 Service & Installation Instructions An Altra Industrial Motion Company Brake (Red) and clutch (Green) indicator lights When
More informationInstallation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator
www..c Installation & Operation Manual Electrak 100 Series / Electromechanical Linear Actuator Thomson has many years of experience designing and manufacturing linear actuators for a wide variety of applications
More informationBLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:
BLHV, BLHV-1 High Voltage Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com #L010015 (714) 992-6990 fax: (714)
More informationBoston Gear Ratiotrol DC Motor Speed Control
Boston Gear Ratiotrol DC Motor Speed Control P-3049-BG Doc. No. 83721 Installation and Operation RG1 and RG2 Models 1/6-1 HP a division of Altra Industrial Motion Contents General Information.....................
More informationUSER'S MANUAL MODEL DPD60001 MICROSTEP DRIVER PACK
COPYRIGHT Copyright 1997 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language,
More informationWIRING DIAGRAMS FOR BRIDGE CONTROL PANELS
WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS Bridge W/D's Panel Part # Page No. Nema-4/12 1-Speed 444231-** 2 Nema-4/12 1-Speed with Soft-Start 444711-** 3 Nema-4/12 2-Speed 444232-** 4 Nema-4/12 2-Speed
More informationCRD610 Automatic Fitting Inserter
CRD610 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 1.2 LAST EDITED 12.12.2018 cleanroomdevices.com 1 Table of Contents Title Page. 1 Table of Contents...2 1.0 General Product & Safety Information....3
More informationBLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA
BLD75-1 Bilevel Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website:
More informationNEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors
Made in the U.S.A. NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Nema Enclosed DC Control Specifications Catalog Number BC140 or Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140
More informationINSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09
HAND CRANK & MOTORIZED POWER CORD REELS: SERIES 1125PC SERIES: 1125PC HAND CRANK SERIES: 1125PC MOTORIZED COXREELS The technical data and images which appear in this manual are for informational purposes
More informationManufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1
STEEL NIPPLES S40 & S80 Steel Nipple Product Specifications Manufacturing Facility is ISO9001:2000 Welded Steel Pipe Conform to ASTM A53 Threads Conform to ASME B1.20.1 800-678-2544 800-678-0857 www.msi-products.com
More informationDPS32001 and DPS32PS1
DPS32001 and DPS32PS1 Driver Pack User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com
More informationCLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"
CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD400 Fitting Inserter OPERATIONS MANUAL VERSION 3.1 LAST EDITED 03.08.11 DOCUMENT NUMBER 001 cleanroomdevices.com 1 Table of Contents
More informationCRD600 Automatic Fitting Inserter
CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.3 LAST EDITED 12.07.2018 cleanroomdevices.com 1 Table of Contents Title Page.. 1 Table of Contents. 2 1.0 General Product & Safety Information...3
More informationInstallation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator
www..com Installation & Operation Manual Electrak 10 Series / Electromechanical Linear Actuator INTRODUCTION Thomson has many years of experience designing and manufacturing linear actuators for a wide
More informationDocument No D1 Revised December Atlantic Ultraviolet Corporation
375 Marcus Boulevard Hauppauge, NY 11788 USA 631.273.0500 Fax: 631.273.0771 e-mail: info@ultraviolet.com Extensive Product Information Available at: www.ultraviolet.com Document No. 98-1138D1 Revised December
More informationMBDC Series
MBDC020-024031 Series 24V, 3A Brush DC Controller User s Guide A N A H E I M A U T O M A T I O N 4985 East Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471
More informationModel NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More informationUser s Manual. Item no. 2561
User s Manual Item no. 2561 Solar e Charger Exec Duo by Wagan Tech User s Manual Read before using this equipment Mini USB Port Power switch Charging jack Basic Operation 1. Insert and attach the iphone
More informationCLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"
CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600 Automatic Fitting Inserter OPERATIONS MANUAL VERSION 2.1 LAST EDITED 7.25.14 DOCUMENT NUMBER 001 cleanroomdevices.com 1 Table of
More informationBlinkerBeam Solar Controller
Blinker Division Solar LED Solutions The Route To Safety, One Solution At A Time BlinkerBeam Solar Controller BlinkerSign, BlinkerBeacon or RRFB 2.0 with 55 W Solar Panel User Guide TAPCO Traffic & Parking
More informationSTAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications
STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications Manufactured in ISO9000:2000 Facility Manufactured to ASTM/ASME A182/SA182 Items conform
More informationSUNTURA SOLAR TRACKER
WindyNation SUNTURA SOLAR TRACKER SOT-TRKS-NF User s Manual Page 1 of 10 WindyNation 08/09/2012 Table of Contents 1 Introduction... 3 1.1 Limited Warranty... 3 1.2 Restrictions... 3 1.3 Warranty Claims
More informationMDC Series
MDC020-024031 Series 24V, 3A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)
More informationOWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP
Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475
More informationINSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL
INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No. 8821 FULL WAVE 4 QUADRANT FWD EN FWD ACCEL REV ACCEL DB MAX IR REV SPD RESP COMP CL FWD CL S/LT NLT OFFSET J8
More informationMBL600 Bilevel Step Motor Driver
MBL600 Bilevel Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website:
More informationCLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"
CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER" CRD600AF Automatic Fitting Inserter With Auto Feed OPERATIONS MANUAL (Shown with optional alcohol dispenser) 1 VERSION 1.1 LAST EDITED
More informationSUNTURA HD SOLAR TRACKER
WindyNation SUNTURA HD SOLAR TRACKER SOT-TRKS-NFHD User s Manual Page 1 of 11 WindyNation 08/09/2012 Table of Contents 1! Introduction... 3! 1.1! Limited Warranty... 3! 1.2! Restrictions... 3! 1.3! Warranty
More informationBLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control
BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control Phone 712.722.4135 groschopp.com 420 15th St NE, Sioux Center, IA 51250 Toll-Free 800.829.4135 Email sales@groschopp.com FAX 712.722.1445
More informationREDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.
REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion KARAM A.L. www.alternatorstarter.com 1-888-515-2726 REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL
More informationInstallation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models
www..com Installation & Operation Manual Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models INTRODUCTION Thomson has many years of experience
More informationPick and Hold Module Pin Assignment and Description
CONNECTION SIGNAL DESCRIPTION CONNECTION SIGNAL DESCRIPTION J1 + PWR This pin should be connected to the positive output of the driver power supply. The maximum voltage applied This should pin should not
More informationCRD400 Fitting Inserter OPERATIONS MANUAL
CRD400 Fitting Inserter OPERATIONS MANUAL ORIGINAL INSTRUCTIONS VERSION 3.4 LAST EDITED 01.07.2019 www.cleanroomdevices.com 1 Table of Contents Title Page.. 1 Table of Contents... 2 1.0 General Product
More information