K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

Size: px
Start display at page:

Download "K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw"

Transcription

1 PRODUCT SPECIFICATIONS PACKAGED ELECTRIC / ELECTRIC KC K-Series Rooftop Units 60 HZ Bulletin No. KCA/KCB (/07) MODEL NUMBER IDENTIFICATION Brand/Family K = K-Series Unit Type C = Packaged Electric Cooling w/ optional Major Design Sequence A = st Generation B = nd Generation Nominal Cooling Capacity - Tons 56 = Tons 80 = 5 Tons 0 = 7.5 Tons 40 = 0 Tons 00 = 5 Tons ASHRAE 90. COMPLIANT to 5 Tons Net Cooling Capacity 5,000 to 70,000 Btuh Optional - 5 to 90 kw Cooling Efficiency H = High Efficiency S = Standard Efficiency K C B 40 S 4 B N Y Refrigerant Type 4 = R-40A Voltage Y = 08/0V- phase-60hz G = 460V- phase-60hz J = 575V- phase-60hz Minor Design Sequence = st Revision = nd Revision = rd Revision Factory Installed N = No Heat Blower Type B = Belt Drive, Constant Air Volume (CAV) M = Single Zone VAV Supply Fan Air Blower, Option, Belt Drive

2 FEATURES AND BENEFITS F C L M N G K H D C A B J I K-Series rooftop units from Allied are the new standard for reliable, efficient rooftop units built for long-lasting performance that can significantly improve indoor and outdoor environments. K-Series rooftop units feature: R-40A Refrigerant - Environmentally friendly Scroll Compressors - Single speed scroll compressors are furnished on all models. Eco-Last Coil System - Smaller, lighter condenser coil. Crankcase Heaters - Protect compressors from refrigerant liquid migration in the off cycle improving product reliability. High Pressure Switches - Protects compressor. Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow. Independent Outdoor Fan Motor Mounts - Allows for easy and efficient service access without removing the top panel. Constant Air Volume (CAV) or Single Zone VAV Supply Fan Blower Option - Allows constant or multi-staged air delivery. Downflow Airflow - Horizontal airflow with optional horizontal curb. Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle. Corrosion-Resistant Removable, Drain Pan - Provides application flexibility, durability and improved serviceability. Thermostatic Expansion Valves (All High Efficiency Models and 00S Model) - Provide peak cooling performance across the entire application range. MERV 8 or MERV Filters - Available as field installed option, provide an enhanced level of indoor air quality, and can help the building qualify for additional LEED credits. Common Components - Many maintenance items are standard throughout the entire product line, reducing the need to carry different parts to the job or maintain in inventory. K-Series Packaged Electric / Electric to 5 Ton / Page

3 FEATURES AND BENEFITS CONTENTS Blower Data Dimensions - Accessories Dimensions - Unit Electrical/ Data Capacities Features And Benefits Model Number Identification Options / Accessories - High Efficiency Models Only Options / Accessories - Standard And High Efficiency Models Options / Accessories - Standard Efficiency Models Only Outdoor Sound Data Ratings - High Efficiency Ratings - Standard Efficiency Specifications - High Efficiency Specifications - Standard Efficiency Unit Clearances Weight Data APPROVALS ETL listed. Efficiency rating CSA. Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes. All models are certified in accordance with the ULE certification program, which is based on AHRI Standard 40/ All models are ASHRAE energy efficiency compliant and meet or exceed requirements of Section 6.8. All models meet DOE 08 energy efficiency standards. Single Zone VAV Supply Fan models meet California Code of Regulations, Title 4 and ASHRAE Section requirements for staged airflow. ISO 900 Registered Manufacturing Quality System. WARRANTY Limited five years on compressors. Limited three years on the Eco-Last Coil System. Limited five years Optional High Performance Economizers. Limited one year all other covered components. B C COOLING SYSTEM Designed to maximize sensible and latent cooling performance at design conditions. System can operate from 0 F to 5 F without any additional controls. R-40A Refrigerant Non-chlorine based, ozone friendly, R-40A. Scroll Compressors Scroll compressors on all models for high performance, reliability and quiet operation. Resiliently mounted on rubber grommets for quiet operation. Compressor Crankcase Heaters Protect against refrigerant migration that can occur during low ambient operation. Thermal Expansion Valves (All High Efficiency Models and 00S Model) Assures optimal performance throughout the application range. Removable element head. Refrigerant Metering Orifice (All Standard Efficiency Models except 00S Model) Accurately meters refrigerant in system. Refrigerant control is accomplished by exact sizing of refrigerant metering orifice. D E Filter/Driers High capacity filter/drier protects the system from dirt and moisture. High Pressure Switches Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation. Freezestats Protects the evaporator coil from damaging ice build-up due to conditions such as low/no airflow, or low refrigerant charge. Eco-Last Coil System Condenser coil features lightweight, all aluminum brazed fin construction. Constructed of three components: a flat extrusion tube, fins inbetween the flat extrusion tubes and two refrigerant manifolds. Eco-Last Coil System Features: Improved heat transfer performance due to high primary surface area (flat tubes) versus secondary surface (fins). Smaller internal volume (reduced refrigerant charge). High durability (all aluminum construction). Fewer brazed joints. Compact design (reduces unit weight). Easy maintenance/cleaning. Face split design. Mounting brackets with rubber inserts secure coil to unit providing vibration dampening and corrosion protection. Angled design in cabinet helps protect coil from possible contact or hail damage. K-Series Packaged Electric / Electric to 5 Ton / Page

4 F FEATURES AND BENEFITS COOLING SYSTEM (continued) Evaporator Coil Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested. Cross row circuiting with rifled tubing optimizes both sensible and latent cooling capacity. Condensate Drain Pan Plastic pan, sloped to meet drainage requirements of ASHRAE 6.. Side or bottom drain connections. Outdoor Coil Fan Motors Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount. Outdoor Coil Fans PVC coated fan guard furnished. Required Selections Cooling Capacity Specify nominal cooling capacity of the unit. Options/Accessories Field Installed Condensate Drain Trap Available in copper or PVC. Drain Pan Overflow Switch Monitors condensate level in drain pan, shuts down unit if drain becomes clogged. Low Ambient Control Cycles the outdoor fans while allowing compressor operation in the cooling cycle. This intermittent fan operation allows the system to operate without icing the evaporator coil and losing capacity. Designed for use in ambient temperatures no lower than 0 F. G CABINET Construction Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation. Base rails have rigging holes. Three sides of the base rail have forklift slots. Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building. Airflow Choice Units are available in downflow (vertical) or horizontal return air flow configuration. Horizontal air flow requires Horizontal Roof Curb. Horizontal Return Air Panel Kit is also required if converting a downflow configured unit to horizontal air flow. Power Entry Electrical lines can be brought through the unit base or through horizontal access knock-outs. Exterior Panels Constructed of heavy-gauge, galvanized steel with a two-layer enamel paint finish. Insulation All panels adjacent to conditioned air are fully insulated with nonhygroscopic fiberglass insulation. Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation. Access Panels Access panels are provided for the economizer/filter section, heating/blower section, and the compressor/controls section. Options/Accessories Factory Installed Corrosion A completely flexible immersed coating with an electrodeposited dry film process. (AST ElectroFin E-Coat) Meets Mil Spec MIL-P-5084, ASTM B7 Standard Method Salt Spray Testing. Indoor Corrosion : - Coated coil - Painted blower housing - Painted indoor base Outdoor Corrosion : - Coated coil - Painted outdoor base Hinged Access Panels Hinged access panels for the filter section, the blower section and compressor/controls section. All hinged panels have seals and quarter-turn latching handles to provide a tight air and water seal. Field Installed Combination Coil/Hail Guards Heavy gauge steel frame painted to match cabinet with expanded metal mesh to protect the outdoor coil from damage. Horizontal Return Air Panel Kit Required for horizontal applications with Horizontal Roof Curb, contains panel with return air opening for field replacement of existing unit panel and panel to cover bottom return air opening in unit, see dimension drawings. K-Series Packaged Electric / Electric to 5 Ton / Page 4

5 H FEATURES AND BENEFITS BLOWER A wide selection of supply air blower options are available to meet a variety of airflow requirements. Motor Overload protected, equipped with ball bearings. Belt drive motors are offered on all models and are available in several different sizes to maximize air performance. Supply Air Blower Forward curved blades, double inlet, blower wheel is statically and dynamically balanced. Equipped with ball bearings and adjustable pulley (allows speed change). Blower assembly slides out of unit for servicing. Required Selections Select Constant Air Volume (CAV) or Single Zone VAV Supply Fan Blower Option On Constant Air volume (CAV) models, the supply air blower will provide a constant volume of air. Single Zone VAV Supply Fan option models utilize a Variable Frequency Drive (VFD) to stage the supply air blower airflow. The VFD alters the frequency and voltage of the power supply to the blower to control blower speed. The supply air blower has two speeds:. Low speed for part-load cooling operation. NOTE - Low speed is 66% of high speed.. High speed for full load cooling and all heat modes. Full speed blower operation is set by adjusting the motor pulley to deliver the desired air volume. The ventilation speed is selectable between high and low speed. NOTE - Part load airflow in cooling mode on Single Zone VAV Supply Fan models should not be set below 0 cfm/nominal full load ton to reduce the risk of evaporator coil freeze-up. The VFD has an operational range of -40 to 5 F outdoor air ambient temperature. Lower operating costs are obtained when the blower is operated on lower speeds. Single Zone VAV Supply Fan Sequence of Operation Ventilation speed is determined by the VENT SPEED switch setting on VFD control board (LO or HI). Blower operates in low speed for mechanical cooling (Y). Blower operates in high speed for any other mode (free cooling, mechanical cooling Y+Y, and heating). Economizer damper minimum position is fully closed in unoccupied mode. In occupied mode, the economizer damper minimum position is determined by the setting of the two potentiometers on VFD control board. LO SPD MIN POS potentiometer sets the minimum position when blower is operating at low speed. HI SPD MIN POS potentiometer sets the minimum position when blower is operating at high speed. Ordering Information Specify standard or high efficiency blower motor, motor horsepower and drive kit number when base unit is ordered, see Drive Kit Specifications Table. Options/Accessories Field Installed VFD Manual Bypass Kit VFD Manual Bypass Control is available as a kit for Single Zone VAV Supply Fan equipped models. The VFD Manual Bypass Control is a manual bypass and is enabled by re-configuring the wiring on the unit. I CONTROLS Unit Control All control voltage is provided via a 4V (secondary) transformer with built-in circuit breaker protection. Heat/Cool Staging - Capable of up to heat / cool staging with a third party DDC control system or thermostat. Low Voltage Terminal Block - Provides screw terminal connections for thermostat or controller wiring. Night Setback Mode - Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only. Options/Accessories Field Installed Smoke Detector Photoelectric type, installed in supply air section, return air section or both sections. Available with power board and single sensor (supply or return) or power board and two sensors (supply and return). Power board located in unit control compartment. K-Series Packaged Electric / Electric to 5 Ton / Page 5

6 J K FEATURES AND BENEFITS ELECTRICAL All units include terminal block and fuse block in power entry junction box for single power entry application. Marked & Color-Coded Wiring All electrical wiring is color-coded and marked to identify which components it is connecting. Electrical Plugs Positive connection electrical plugs are used to connect common accessories or maintenance parts for easy removal or installation. Required Selections Voltage Choice Specify when ordering base unit. Options/Accessories Factory or Field Installed Disconnect Switch Accessible from outside of unit, spring loaded weatherproof cover furnished. GFI Service Outlets () 5V ground fault circuit interrupter (GFCI) type, non-powered, fieldwired. Field Installed Helix wound nichrome elements, individual element limit controls, wiring harness. Unit fuse block is furnished as standard. See Options / Accessories tables for ordering information. GFI Weatherproof Cover Single-gang cover. Heavy-duty UV-resistant polycarbonate case construction. Hinged base cover with gasket. L Phase Monitor Phase monitor detects the phasing of incoming power. If the incoming power is out of phase or if any of the three phases are lost, an indicator LED on the phase monitor will turn red and the unit will not start. In normal operation with correct incoming power phasing, the LED will be green. NOTE - Phase Monitor is factory Installed in the control compartment on all units equipped with the Single Zone VAV Supply Fan option. INDOOR AIR QUALITY Air Filters Disposable inch filters furnished as standard. Options/Accessories Field Installed High Efficiency Air Filters Disposable MERV 8 or MERV ( Efficiency Reporting Value based on ASHRAE 5.) efficiency inch pleated filters. UVC Germicidal Lamps Germicidal lamps emit ultra-violet (UV-C) energy, which has been proven to be effective in reducing microbes such as viruses, bacteria, yeasts, and molds. This process either destroys the organism or controls its ability to reproduce. UV-C energy greatly reduces the growth and proliferation of mold and other bioaerosols (bacteria and viruses) on illuminated surfaces (particularly coil and drain pan). Lamps are field installed in the blower/evaporator coil section. All necessary hardware for installation is included. Lamps operate on 08/0V power supply. Step-down transformer must be field supplied when used with 460V and 575V rooftop units. Magnetic safety interlock terminates power when access panels are removed. Approved by ETL. Indoor Air Quality (CO ) Sensors Monitors CO levels, reports to the Unit Controller which adjusts economizer dampers as needed. K-Series Packaged Electric / Electric to 5 Ton / Page 6

7 OPTIONS / ACCESSORIES M ECONOMIZER OPTIONS Factory or Field Installed Economizer (Standard and High Performance Common Features) Outdoor Air Hood with mist elimination filter is furnished. Mixed Air Sensor is furnished for field installation in the rooftop unit. Sensor is factory installed when Economizers are factory installed. Standard Economizer Features (Not for Title 4) Gear-driven action, return air and outdoor air dampers, plugin connections to unit, nylon bearings, neoprene seals, 4-volt, fully-modulating spring return motor. Standard Economizer Control Module (Not for Title 4) The Standard Economizer Control Module can be adjusted to operate based on outdoor air temperatures. Economizer Controls: Damper Position - Can be set lower than traditional minimum air requirements resulting in cost savings. IAQ Sensor - Signals dampers to modulate and maintain 55 F when CO is higher than the CO setpoint. Demand Control Ventilation (DCV) LED - A steady green Demand Control Ventilation LED indicates the IAQ reading is higher than setpoint and requires more fresh air. Free Cool LED - A steady green LED indicates outdoor air is suitable for free cooling. Free Cooling runs when outdoor air temperature is lower than the set temperature on the economizer control. NOTE: The Free Cooling default setting for outdoor air temperature sensor is 55 F. High Performance Economizer Features Approved for California Title 4 building standards. Low leakage dampers are Air Movement and Control Association International (AMCA) Class A Certified - CFM per sq. ft. leakage at in. w.g. ASHRAE compliant. Gear-driven action, high torque 4-volt fully-modulating spring return damper motor, return air and outdoor air dampers, plug-in connections to unit, stainless steel bearings, enhanced neoprene blade edge seals and flexible stainless steel jamb seals to minimize air leakage. NOTE - High Performance Economizers are not approved for use with enthalpy controls in Title 4 applications. High Performance Economizer Control Module Module provides inputs and outputs to control economizer based on parameter settings. Module automatically detects sensors by polling to determine which sensors are installed in system. Module displays any alarm messages (fault detection and diagnostics) as an aid in troubleshooting. Non-volatile memory retains parameter settings in case of power failure. Keypad with four navigation buttons and LCD screen is furnished for setting economizer parameters. Menu Up/Exit button returns to the main menu. Arrow Up button moves to the previous or next parameter within the selected menu. Arrow Down button moves to the next parameter within the selected menu. Select (enter) button confirms parameter selection. Main Menu Structure: STATUS (economizer and system operation status) SETPOINTS (settings for various setpoint parameters) SYSTEM SETUP (settings/ information about the system) ADVANCED SETUP (freeze protection, CO settings, stage delay and additional calibration settings) CHECKOUT (damper positions) ALARMS (output signal that can be configured for remote alarm monitoring) NOTE - The Free Cooling setpoint for Title 4 applications must be set based on the Cimate Zone where the system is installed. See Section 40.4 Prescriptive Requirements for Space Conditioning Systems of the California Energy Commision s 0 Building Energy Efficiency Standards. Refer to Installation Instructions for complete setup information and menu parameters available. Factory or Field Installed Single Enthalpy Control (Not for Title 4) Outdoor air enthalpy sensor enables Economizer if the outdoor enthalpy is less than the setpoint of the control. Field Installed Differential Enthalpy Control (Not for Title 4) Order two Single Enthalpy Controls. One is field installed in the return air section, the other in the outdoor air section. Allows the economizer control board to select between outdoor air or return air, whichever has lower enthalpy. K-Series Packaged Electric / Electric to 5 Ton / Page 7

8 N O OPTIONS / ACCESSORIES EXHAUST OPTIONS Factory or Field Installed Downflow Barometric Relief Dampers With Exhaust Hood Allow relief of excess air. Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle. Exhaust hood with bird screen is furnished. Field Installed Horizontal Barometric Relief Dampers With Exhaust Hood For use when unit is configured for horizontal applications requiring an economizer. Allows relief of excess air. Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle. Field installed in return air duct. Exhaust hood with bird screen is furnished. Fans Installs internal to unit for downflow applications only with economizer option. Provides exhaust air pressure relief. Interlocked to run when supply air blower is operating, fans run when outdoor air dampers are 50% open (adjustable), motor is overload protected. Requires Economizer with Outdoor Air Hood and Downflow Barometric Relief Dampers. Dual fans are 0 in. diameter with 5 blades with () / hp motors. OUTDOOR AIR OPTIONS Factory or Field Installed Outdoor Air Damper - Downflow or Horizontal With Air Hood Linked mechanical dampers, 0 to 5% (fixed) outdoor air adjustable, installs in unit. Includes outdoor air hood. Automatic model features fully modulating spring return damper motor with plug-in connection. Manual model features parallel blade, gear-driven dampers with adjustable fixed position. Outdoor Air Hood is included when damper is factory installed and is furnished with damper when ordered for field installation. ROOF CURBS Nailer strip furnished (downflow only), mates to unit, US National Roofing Contractors Approved, shipped knocked down. Hybrid Roof Curbs, Downflow Roof curb can be assembled using interlocking tabs to fasten corners together. No tools required. Curb can also be fastened together with furnished hardware. Available in 8, 4, 8, and 4 inch heights. Adjustable Pitch Curb, Downflow Fully adjustable pitch curbs (/4 in. per foot in any direction) provide a level platform for rooftop units allowing flexible installations on roofs with uneven or sloped angles. Uses interlocking tabs to fasten corners together. No tools required. Hardware is furnished to connect upper curb with lower curb. Available in 4 inch height. Horizontal Converts unit from downflow to horizontal (side) air flow, return air is on unit, supply air is on curb, see dimension drawings. Curbs for rooftop applications meet National Roofing Code requirements. Requires Horizontal Return Air Panel Kit. Available in 6, 0, 7 and 4 inch heights. Optional Insulation Kit is available to help prevent sweating. Adaptor Curbs (not shown) Curbs are regionally sourced. Dimensions will vary based upon the source. Contact your local sales representative for a detailed cut sheet with applicable dimensions. CEILING DIFFUSERS Ceiling Diffusers (Flush or Step-Down) Diffuser face and grilles with white powder coat finish, insulated (UL listed duct liner), diffuser box with collars for duct connection, fixed blades (flush diffusers) and double deflection blades (stepdown diffusers), provisions for suspending, internally sealed (prevents recirculation), removable return air grille, adapts to T-bar ceiling grids or plaster ceilings. Transitions (Supply and Return) Used with diffusers, installs in roof curb, galvanized steel construction, flanges furnished for duct connection to diffusers, fully insulated. K-Series Packaged Electric / Electric to 5 Ton / Page 8

9 OPTIONS / ACCESSORIES - STANDARD AND HIGH EFFICIENCY MODELS Item Description COOLING SYSTEM Model Number Catalog Number KCA 56 Unit Model No. Condensate Drain Trap PVC - CTRAP0AD 76W6 X X X X X KCA KCB 80 KCA KCB 0 KCA KCB 40 Copper - CTRAP0AD 76W7 X X X X X Corrosion Factory O O O O O Drain Pan Overflow Switch CSNSR7FF- 0C4 X X X X X Efficiency Standard or High Factory O O O O O Refrigerant Type R-40A O O O O O BLOWER - SUPPLY AIR Blower Option CAV (Constant Air Volume) Factory O O O O O KCB 00 Single Zone VAV Supply Factory O O O O O Motors - Constant Air Volume (CAV) Belt Drive (standard efficiency) - hp Factory O Belt Drive (standard efficiency) - hp Factory O O O Belt Drive (standard efficiency) - 5 hp Factory O O O O O Belt Drive (standard efficiency) hp Factory O O O O Belt Drive (standard efficiency) - 0 hp Factory O O Motors -Single Zone VAV Supply Belt Drive (standard efficiency) - hp Factory O VFD Manual Bypass Kit (for Single Zone VAV Supply equipped units) Drive Kits See Blower Data Tables for usage and selection CABINET Belt Drive (standard efficiency) - hp Factory O O O Belt Drive (standard efficiency) - 5 hp Factory O O O O O Belt Drive (standard efficiency) hp Factory O O O O Belt Drive (standard efficiency) - 0 hp Factory O O,, 5 hp (08/0V),, 5, 7.5, 0 hp (460V and 575V) KVFDBC- 90W5 X X X X X 7.5, 0 hp (08/0V) KVFDB0C- 90W5 X X X X Kit # rpm Factory O O O Kit # rpm Factory O O O Kit # rpm Factory O O O O O Kit # rpm Factory O O O O O Kit # rpm Factory O O O O O Kit # rpm Factory O O O O Kit # rpm Factory O O O O Kit # rpm Factory O O O O Kit # rpm Factory O O Kit # 5-65 rpm Factory O O Hinged Access Panels Factory O O O O O CONTROLS Commercial Controls BACnet K0CTRLC- 96W6 OX OX OX OX OX BACnet Sensor with Display K0SNSR0FF 97W X X X X X BACnet Sensor without Display K0SNSR00FF 97W4 X X X X X Novar 05 K0CTRL0C- 96W OX OX OX OX OX Plenum Cable (75 ft.) K0MISC00FF 97W5 X X X X X Smoke Detector - Supply or Return (Power board and one sensor) CSNSR44C- 8W40 X X X X X Smoke Detector - Supply and Return (Power board and two sensors) CSNSR4C- 8W4 X X X X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed K-Series Packaged Electric / Electric to 5 Ton / Page 9

10 OPTIONS / ACCESSORIES - STANDARD AND HIGH EFFICIENCY MODELS Item Description ELECTRICAL Model Number Catalog Number KCA 56 Unit Model No. Voltage 60 hz 08/0V - phase Factory O O O O O KCA KCB 80 KCA KCB 0 KCA KCB 40 KCB V - phase Factory O O O O O 575V - phase Factory O O O O O Disconnect Switch (see Tables for usage) 80 amp - CDISC080C- 54W85 OX OX OX OX OX 50 amp - CDISC50C- 54W86 OX OX OX OX OX 50 amp - CDISC50C- 54W87 OX OX OX OX OX GFI Service Outlets 5 amp non-powered, field-wired (08/0V, 460V only) LTAGFIK0/5 74M70 X OX OX OX OX 0 amp non-powered, field-wired (575V only) CGFCI0FF 67E0 X X X X X Weatherproof Cover for GFI CGFCI99FF 0C89 X X X X X Phase Monitor CPHZM0FF- 0C5 X X X X X ELECTRIC HEAT 5 kw 08/0V-ph - CEH050C-Y 5W84 OX OX OX OX OX 460V-ph - CEH050C-G 5W86 OX OX OX OX OX 575V-ph - CEH050C-J 5W87 OX OX OX OX OX 0 kw 08/0V-ph - CEH000CY 5W88 OX 460V-ph - CEH000CG 5W90 OX 575V-ph - CEH000CJ 5W9 OX 08/0V-ph - CEH000CY 5W9 OX OX OX OX 460V-ph - CEH000CG 5W94 OX OX OX OX 575V-ph - CEH000CJ 5W95 OX OX OX OX 45 kw 08/0V-ph - CEH0450CY 5W96 OX 460V-ph - CEH0450CG 5W98 OX 575V-ph - CEH0450CJ 5W99 OX 08/0V-ph - CEH0450CY 54W00 OX OX OX OX 460V-ph - CEH0450CG 54W0 OX OX OX OX 575V-ph - CEH0450CJ 54W0 OX OX OX OX 60 kw 08/0V-ph - CEH0600CY 54W04 OX 460V-ph - CEH0600CG 54W06 OX 575V-ph - CEH0600CJ 54W07 OX 08/0V-ph - CEH0600CY 54W08 OX OX OX OX 460V-ph - CEH0600CG 54W0 OX OX OX OX 575V-ph - CEH0600CJ 54W OX OX OX OX 90 kw 08/0V-ph - CEH0900C-Y 54W OX OX OX 460V-ph - CEH0900C-G 54W4 OX OX OX Factory installed on all Single Zone VAV Supply Fan equipped units. 575V-ph - CEH0900C-J 54W5 OX OX OX NOTE - Factory installed electric heat is only available with high efficiency models. NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed K-Series Packaged Electric / Electric to 5 Ton / Page 0

11 OPTIONS / ACCESSORIES - STANDARD AND HIGH EFFICIENCY MODELS Item Description INDOOR AIR QUALITY Air Filters High Efficiency Air Filters 4 x 4 x in. (Order 6 per unit) Replacement Media Filter With Metal Mesh Frame (includes non-pleated filter media) Indoor Air Quality (CO ) Sensors Model Number Catalog Number KCA 56 Unit Model No. KCA KCB 80 KCA KCB 0 KCA KCB 40 MERV 8 - CFLTR5C-- 54W67 X X X X X MERV - CFLTR40C-- 5W40 X X X X X KCB 00 CFLTR0C-- 44N6 X X X X X Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AEL 77N9 X X X X X Sensor - Wall-mount, off-white plastic cover, no display C0SNSR5AEL 87N5 X X X X X Sensor - Black plastic case with LCD display, rated for plenum mounting Sensor - Wall-mount, black plastic case, no display, rated for plenum mounting C0SNSR5AEL 87N5 X X X X X C0MISC9AE 87N54 X X X X X CO Sensor Duct Mounting Kit - for downflow applications C0MISC9AE- 85L4 X X X X X Aspiration Box - for duct mounting non-plenum rated CO sensors (87N5 or 77N9) UVC Germicidal Light Kit C0MISC6AE- 90N4 X X X X X UVC Light Kit (0/0V-ph) CUVCL0C- 54W65 X X X X X ECONOMIZER Standard Economizer With Outdoor Air Hood (Not for Title 4) Standard Economizer Downflow or Horizontal Applications - Includes Outdoor Air Hood, order Downflow or Horizontal Barometric Relief Dampers separately Standard Economizer Controls (Not for Title 4) KECON0C- U48 OX OX OX OX OX Single Enthalpy Control CSNSR64FF 5W64 OX OX OX OX OX Differential Enthalpy Control (order ) CSNSR64FF 5W64 X X X X X High Performance Economizer With Outdoor Air Hood (For Title 4) / AMCA Class A Certified High Performance Economizer Downflow or Horizontal Applications - Includes Outdoor Air Hood, order Downflow or Horizontal Barometric Relief Dampers separately High Performance Economizer Controls (Not for Title 4) KECONC- 0U6 OX OX OX OX OX Single Enthalpy Control CSNSR60FF 0Z75 OX OX OX OX OX Differential Enthalpy Control (order ) CSNSR60FF 0Z75 X X X X X Barometric Relief Dampers With Exhaust Hood Downflow Barometric Relief Dampers CDAMP50C 54W78 OX OX OX OX OX Horizontal Barometric Relief Dampers LAGEDH8/4 6K99 X X X X X OUTDOOR AIR Outdoor Air Dampers With Outdoor Air Hood Motorized CDAMP0C- U04 OX OX OX OX OX Manual CDAMP0C- U05 OX OX OX OX OX POWER EXHAUST (DOWNFLOW APPLICATIONS ONLY) Standard Static 08/0V - CPWREC-Y 75W90 X X X X X 460V - CPWREC-G 75W9 X X X X X 575V - CPWREC-J 75W9 X X X X X Lamps operate on 0-0V single-phase power supply. Step-down transformer must be field supplied for field installation in 460V and 575V rooftop units (transformer is furnished for factory installed light kits). Alternately, a separate 0V power supply may be used to directly power the UVC ballast(s) NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed K-Series Packaged Electric / Electric to 5 Ton / Page

12 OPTIONS / ACCESSORIES - STANDARD AND HIGH EFFICIENCY MODELS Item Description Model Number Catalog Number KCA 56 Unit Model No. ROOF CURBS Hybrid Roof Curbs, Downflow 8 in. height CCURB70C- F58 X X X X X 4 in. height CCURB7C- F59 X X X X X 8 in. height CCURB7C- F60 X X X X X 4 in. height CCURB7C- F6 X X X X X Adjustable Pitch Curb 4 in. height LCURB55C 4W6 X X X X X Standard Roof Curbs, Horizontal - Requires Horizontal Return Air Panel Kit 6 in. height - slab applications CCURB4C- T89 X X X X 0 in. height - slab applications CCURB5C- T90 X 7 in. height - rooftop applications CCURB6C- T96 X X X X 4 in. height - rooftop applications CCURB7C- T97 X Insulation Kit For Standard Horizontal Curbs for CCURB4C- CINSUC-- 7K X X X X for CCURB5C- CINSUC-- 7K X for CCURB6C- CINSUC-- 7K4 X X X X for CCURB7C- CINSU4C-- 7K5 X Horizontal Return Air Panel Kit Required for Horizontal Applications with Roof Curb CHRAP0C-- 87M00 X X X X X CEILING DIFFUSERS Step-Down - Order one RTD-85S K6 X X RTD-75S K64 X X X Flush - Order one FD-85S K58 X X FD-75S K59 X X X Transitions (Supply and Return) - Order one CDIFFC- X68 X X CDIFF4C- X70 X X X NOTE - Catalog and model numbers shown are for ordering field installed accessories. OX - Configure To Order (Factory Installed) or Field Installed O = Configure To Order (Factory Installed) X = Field Installed KCA KCB 80 KCA KCB 0 KCA KCB 40 KCB 00 OPTIONS / ACCESSORIES - STANDARD EFFICIENCY MODELS ONLY Item Description Model Number Catalog Number KCA 80S Unit Model No. KCB KCB KCB 80S 0S 40S COOLING SYSTEM Low Ambient Control KLOAM5C 0T6 X KLOAM5C 0T6 X X KLOAM5C 0T64 X KLOAM54C 0T65 X CABINET Combination Coil/Hail Guards CGARD5C 5T9 X X X CGARD5C 5T9 X X KCB 00S OPTIONS / ACCESSORIES - HIGH EFFICIENCY MODELS ONLY Item Description K-Series Packaged Electric / Electric to 5 Ton / Page Model Number Catalog Number KCA 56H Unit Model No. KCA KCA 80H 0H COOLING SYSTEM Low Ambient Control KLOAM5C 0T6 X KLOAM5C 0T64 X X KLOAM54C 0T65 X CABINET Combination Coil/Hail Guards CGARD5C 5T9 X CGARD5C 5T9 X X X KCA 40H

13 SPECIFICATIONS - STANDARD EFFICIENCY General Data Nominal Tonnage 5 Ton 5 Ton 7.5 Ton 7.5 Ton Model Number KCB80S4B KCA80S4M KCB0S4B KCA0S4M Efficiency Type Standard Standard Standard Standard Blower Type Constant Air Volume (CAV) Single Zone VAV Supply Fan Constant Air Volume (CAV) Single Zone VAV Supply Fan Cooling Performance Gross Cooling Capacity - Btuh 8,000 8,000 06,000 04,000 Net Cooling Capacity - Btuh 76,000 76,000 00,000 98,000 AHRI Rated Air Flow - cfm Unit Power - kw EER (Btuh/Watt) IEER (Btuh/Watt) Refrigerant Type R-40A R-40A R-40A R-40A Refrigerant 5 lbs. 4 oz. 7 lbs. 8 oz. 6 lbs. 8 oz. 5 lbs. oz. Charge 5 lbs. oz. 7 lbs. 8 oz. 6 lbs. 4 oz. 5 lbs. 8 oz. Furnished 5 lbs. oz lbs. oz. 5 lbs. 8 oz. Available, see page kw kw Compressor Type (number) Scroll () Scroll () Scroll () Scroll () Outdoor Coils Outdoor Coil Fans Net face area (total) - sq. ft Number of rows Fins per inch Motor - (No.) horsepower () / () / () / () / Motor rpm Motor watts Diameter - (No.) in. () 4 () 4 () 4 () 4 Number of blades Air volume - cfm,000,000,000,000 Indoor Coils Net face area (total) - sq. ft Tube diameter - in. /8 /8 /8 /8 Number of rows 4 Fins per inch Drain connection - No. and size () in. FPT () in. FPT () in. FPT () in. FPT Expansion device type Refrigerant Metering Orifice (RFC) Indoor Blower and Drive Selection Nominal motor output usable motor output (US Only) Motor - Drive kit number hp, 5 hp, 7.5 hp.45 hp, 5.75 hp, 8.6 hp hp Kit rpm Kit rpm 5 hp Kit rpm Kit rpm Kit rpm 7.5 hp Kit rpm Kit rpm Kit rpm () 5 x 5 () 5 x 5 () 5 x 5 () 5 x 5 Blower wheel nominal diameter x width - in. Filters Type of filter Fiberglass, disposable Number and size - in. (6) 4 x 4 x Electrical characteristics 08/0V, 460V or 575V - 60 hertz - phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. AHRI Certified to AHRI Standard 40/60; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Integrated Energy Efficiency Ratio tested according to AHRI Standard 40/60. Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. NOTE Units equipped with Single Zone VAV Supply Fan option are limited to a motor service factor of.0. K-Series Packaged Electric / Electric to 5 Ton / Page

14 SPECIFICATIONS - STANDARD EFFICIENCY General Data Nominal Tonnage 0 Ton 0 Ton 5 Ton 5 Ton Model Number KCB40S4B KCA40S4M KCB00S4B KCB00S4M Efficiency Type Standard Standard Standard Standard Blower Type Constant Air Volume (CAV) Single Zone VAV Supply Fan Constant Air Volume (CAV) Single Zone VAV Supply Fan Cooling Performance Gross Cooling Capacity - Btuh 6,000 8,000 8,000 8,000 Net Cooling Capacity - Btuh 0,000 8,000 70,000 70,000 AHRI Rated Air Flow - cfm Unit Power - kw EER (Btuh/Watt) IEER (Btuh/Watt) Refrigerant Type R-40A R-40A R-40A R-40A Refrigerant 7 lbs. 0 oz. 7 lbs. 4 oz. 6 lbs. 4 oz. 6 lbs. 4 oz. Charge 7 lbs. 4 oz. 7 lbs. 4 oz. 5 lbs. 0 oz. 5 lbs. 0 oz. Furnished 7 lbs. 0 oz. 6 lbs. 4 oz. 6 lbs. 6 oz. 6 lbs. 6 oz lbs. 0 oz. 6 lbs. 0 oz. Available, see page kw kw Compressor Type (number) Scroll () Scroll () Scroll (4) Scroll (4) Outdoor Coils Outdoor Coil Fans Net face area (total) - sq. ft Number of rows Fins per inch 0 0 Motor - (No.) horsepower (4) / (4) / (6) / (6) / Motor rpm Motor watts Diameter - (No.) in. (4) 4 (4) 4 (6) 4 (6) 4 Number of blades Air volume - cfm 6,000 6,000 0,000 0,000 Indoor Coils Net face area (total) - sq. ft Tube diameter - in. /8 /8 /8 /8 Number of rows Fins per inch Drain connection - No. and size () in. FPT () in. FPT () in. FPT () in. FPT Expansion device type Refrigerant Metering Orifice (RFC) Balanced port TXV, removable head Indoor Blower and Drive Selection Nominal motor output usable motor output (US Only) Motor - Drive kit number 5 hp, 7.5 hp, 0 hp 5.75 hp, 8.6 hp,.5 hp 5 hp Kit rpm Kit rpm Kit rpm 7.5 hp Kit rpm Kit rpm Kit rpm 0 hp Kit rpm Kit rpm Kit 5-65 rpm () 5 x 5 () 5 x 5 () 5 x 5 () 5 x 5 Blower wheel nominal diameter x width - in. Filters Type of filter Fiberglass, disposable Number and size - in. (6) 4 x 4 x Electrical characteristics 08/0V, 460V or 575V - 60 hertz - phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. AHRI Certified to AHRI Standard 40/60; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Integrated Energy Efficiency Ratio tested according to AHRI Standard 40/60. Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. NOTE Units equipped with Single Zone VAV Supply Fan option are limited to a motor service factor of.0. K-Series Packaged Electric / Electric to 5 Ton / Page 4

15 SPECIFICATIONS - HIGH EFFICIENCY General Data Nominal Tonnage Ton Ton 5 Ton 5 Ton Model Number KCA56H4B KCA56H4M KCA80H4B KCA80H4M Efficiency Type High High High High Blower Type Constant Air Volume (CAV) Single Zone VAV Supply Fan Constant Air Volume (CAV) Single Zone VAV Supply Fan Cooling Performance Gross Cooling Capacity - Btuh 56,000 56,000 76,000 76,000 Net Cooling Capacity - Btuh 5,000 5,000 7,000 7,000 AHRI Rated Air Flow - cfm Unit Power - kw EER (Btuh/Watt) IEER (Btuh/Watt) Refrigerant Type R-40A R-40A R-40A R-40A Refrigerant 5 lbs. 4 oz. 5 lbs. 4 oz. 6 lbs. 0 oz. 6 lbs. 0 oz. Charge 5 lbs. 8 oz. 5 lbs. 8 oz. 5 lbs. 0 oz. 5 lbs. 0 oz. Furnished 5 lbs. oz. 5 lbs. oz. 5 lbs. 4 oz. 5 lbs. 4 oz. Available, see page kw kw Compressor Type (number) Scroll () Scroll () Scroll () Scroll () Outdoor Coils Outdoor Coil Fans Net face area (total) - sq. ft Number of rows Fins per inch Motor - (No.) horsepower () / () / (4) / (4) / Motor rpm Motor watts Diameter - (No.) in. () 4 () 4 (4) 4 (4) 4 Number of blades Air volume - cfm ,000 6,000 Indoor Coils Net face area (total) - sq. ft Tube diameter - in. /8 /8 /8 /8 Number of rows Fins per inch Drain connection - No. and size () in. FPT () in. FPT () in. FPT () in. FPT Expansion device type Balanced port TXV, removable head Indoor Blower and Drive Selection Nominal motor output hp, hp, 5 hp hp, 5 hp, 7.5 hp usable motor. hp,.45 hp, 5.75 hp.45 hp, 5.75 hp, 8.6 hp output (US Only) Motor - Drive kit number hp Kit rpm Kit rpm hp Kit rpm Kit rpm 5 hp Kit rpm Kit rpm Kit rpm hp Kit rpm Kit rpm 5 hp Kit rpm Kit rpm Kit rpm 7.5 hp Kit rpm Kit rpm Kit rpm Blower wheel nominal diameter x width - in. () 5 x 5 () 5 x 5 () 5 x 5 () 5 x 5 Filters Type of filter Fiberglass, disposable Number and size - in. (6) 4 x 4 x Electrical characteristics 08/0V, 460V or 575V - 60 hertz - phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. AHRI Certified to AHRI Standard 40/60; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Integrated Energy Efficiency Ratio tested according to AHRI Standard 40/60. Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. NOTE Units equipped with Single Zone VAV Supply Fan option are limited to a motor service factor of.0. K-Series Packaged Electric / Electric to 5 Ton / Page 5

16 SPECIFICATIONS - HIGH EFFICIENCY General Data Nominal Tonnage 7.5 Ton 7.5 Ton 0 Ton 0 Ton Model Number KCA0H4B KCA0H4M KCA40H4B KCA40H4M Efficiency Type High High High High Blower Type Constant Air Volume (CAV) Single Zone VAV Supply Fan Constant Air Volume (CAV) Single Zone VAV Supply Fan Cooling Performance Gross Cooling Capacity - Btuh 04,000 04,000 8,000 8,000 Net Cooling Capacity - Btuh 94,000 94,000 0,000 0,000 AHRI Rated Air Flow - cfm Unit Power - kw EER (Btuh/Watt) IEER (Btuh/Watt) Refrigerant Type R-40A R-40A R-40A R-40A Refrigerant 6 lbs. oz. 6 lbs. oz. 6 lbs. 4 oz. 6 lbs. 4 oz. Charge 6 lbs. 4 oz. 6 lbs. 4 oz. 6 lbs. oz. 6 lbs. oz. Furnished 6 lbs. 4 oz. 6 lbs. 4 oz. 5 lbs. 4 oz. 5 lbs. 4 oz lbs. 6 oz. 5 lbs. 6 oz. Available, see page <?> kw kw Compressor Type (number) Scroll () Scroll () Scroll (4) Scroll (4) Outdoor Coils Outdoor Coil Fans Net face area (total) - sq. ft Number of rows Fins per inch Motor - (No.) horsepower (6) / (6) / (6) / (6) / Motor rpm Motor watts Diameter - (No.) in. (6) 4 (6) 4 (6) 4 (6) 4 Number of blades Air volume - cfm 0,000 0,000 0, Indoor Coils Net face area (total) - sq. ft Tube diameter - in. /8 /8 /8 /8 Number of rows Fins per inch Drain connection - No. and size () in. FPT () in. FPT () in. FPT () in. FPT Expansion device type Balanced port TXV, removable head Indoor Blower and Drive Selection Nominal motor output hp, 5 hp, 7.5 hp 5 hp, 7.5 hp, 0hp usable motor.45 hp, 5.75 hp, 8.6 hp 5.75 hp, 8.6 hp,.5 hp output (US Only) Motor - Drive kit number hp Kit rpm Kit rpm 5 hp Kit rpm Kit rpm Kit rpm 7.5 hp Kit rpm Kit rpm Kit rpm 5 hp Kit rpm Kit rpm Kit rpm 7.5 hp Kit rpm Kit rpm Kit rpm 0 hp Kit rpm Kit rpm Kit 5-65 rpm Blower wheel nominal diameter x width - in. () 5 x 5 () 5 x 5 () 5 x 5 () 5 x 5 Filters Type of filter Fiberglass, disposable Number and size - in. (6) 4 x 4 x Electrical characteristics 08/0V, 460V or 575V - 60 hertz - phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. AHRI Certified to AHRI Standard 40/60; 95 F outdoor air temperature and 80 F db/67 F wb entering evaporator air; minimum external duct static pressure. Integrated Energy Efficiency Ratio tested according to AHRI Standard 40/60. Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. NOTE Units equipped with Single Zone VAV Supply Fan option are limited to a motor service factor of.0. K-Series Packaged Electric / Electric to 5 Ton / Page 6

17 RATINGS - STANDARD EFFICIENCY NOTE - For s and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 5 TON STANDARD EFFICIENCY KCB80S4B (ST STAGE) - CONSTANT AIR VOLUME Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To Cap. Input Dry Cap. Input Dry Cap. Input Dry Cap. Input Dry F F F TON STANDARD EFFICIENCY KCB80S4B (ND STAGE) - CONSTANT AIR VOLUME Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To Cap. Input Dry Cap. Input Dry Cap. Input Dry Cap. Input Dry F F F TON STANDARD EFFICIENCY KCA80S4M (ST STAGE) - SINGLE ZONE VAV SUPPLY AIR FAN BLOWER Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To Cap. Input Dry Cap. Input Dry Cap. Input Dry Cap. Input Dry F F F TON STANDARD EFFICIENCY KCA80S4M (ND STAGE) - SINGLE ZONE VAV SUPPLY AIR FAN BLOWER Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To Cap. Input Dry Cap. Input Dry Cap. Input Dry Cap. Input Dry F F F K-Series Packaged Electric / Electric to 5 Ton / Page 7

18 RATINGS - STANDARD EFFICIENCY NOTE - For s and Capacities not shown in tables, see bulletin - Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 7.5 TON STANDARD EFFICIENCY KCB0S4B (ST STAGE) - CONSTANT AIR VOLUME Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To Cap. Input Dry Cap. Input Dry Cap. Input Dry Cap. Input Dry F F F TON STANDARD EFFICIENCY KCB0S4B (ND STAGE) - CONSTANT AIR VOLUME Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To Cap. Input Dry Cap. Input Dry Cap. Input Dry Cap. Input Dry F F F TON STANDARD EFFICIENCY KCA0S4M (ST STAGE) - SINGLE ZONE VAV SUPPLY AIR FAN BLOWER Outdoor Air Outdoor Coil 65 F 75 F 85 F 95 F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To Cap. Input Dry Cap. Input Dry Cap. Input Dry Cap. Input Dry F F F TON STANDARD EFFICIENCY KCA0S4M (ND STAGE) - SINGLE ZONE VAV SUPPLY AIR FAN BLOWER Outdoor Air Outdoor Coil 85 F 95 F 05 F 5 F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To Cap. Input Dry Cap. Input Dry Cap. Input Dry Cap. Input Dry F F F K-Series Packaged Electric / Electric to 5 Ton / Page 8

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT. 13 to 25 Tons Net Cooling Capacity 152,000 to 270,000 Btuh Optional Electric Heat - 15 to 90 kw PRODUCT SPECIFICATIONS PACKAGED ELECTRIC / ELECTRIC KC K-Series Rooftop Units 60 HZ Bulletin No. KCA-56-00 (/04) MODEL NUMBER IDENTIFICATION Brand/Family K = K-Series Unit Type C = Packaged Electric Cooling

More information

K-Series Rooftop Units 50 HZ

K-Series Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC / ELECTRIC KC K-Series Rooftop Units 50 HZ Bulletin No. KCA/KCB-56-300-50HZ (2/207) 45.7 to 88 kw (3 to 25 Tons) Net ing Capacity - 38. to 68.6 kw (30 000 to 234

More information

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP KH K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KHA-80-240 (6/207) MODEL NUMBER IDENTIFICATION Brand/Family K = K-Series Unit Type H = Packaged Heat Pump Major Design

More information

K-Series Rooftop Units 60 HZ

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC KG K-Series Rooftop Units 60 HZ Bulletin No. KGA-80-00 (6/0) MODEL NUMBER IDENTIFICATION ASHRAE 90. COMPLIANT to 5 Tons Net Cooling Capacity 5,000 to 70,000

More information

Landmark Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

Landmark Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC / ELECTRIC KC Landmark Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. 0550 May 07 Supersedes February 07 MODEL NUMBER IDENTIFICATION K C A 0 H 4 B N Y Brand/Family K = Landmark

More information

K-Series Rooftop Units 60 HZ

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP KH K-Series Rooftop Units 60 HZ Bulletin No. KHA-092-50 (3/204) MODEL NUMBER IDENTIFICATION ASHRAE 90. COMPLIANT 7.5 to 2.5 Tons Net Cooling Capacity 87,000 to

More information

ZCA. Raider Rooftop Units 60 HZ. ASHRAE 90.1 COMPLIANT 3 to 6 Tons Net Cooling Capacity 34,600 to 68,000 Btuh Optional Electric Heat - 5 to 30 kw

ZCA. Raider Rooftop Units 60 HZ. ASHRAE 90.1 COMPLIANT 3 to 6 Tons Net Cooling Capacity 34,600 to 68,000 Btuh Optional Electric Heat - 5 to 30 kw PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric ZCA Raider Rooftop Units 60 HZ Bulletin No. 0748 November 07 Supersedes June 07 Value Without Compromise MODEL NUMBER IDENTIFICATION Z C A 060 S 4 B N

More information

Landmark Rooftop Units 50 HZ

Landmark Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC KG Landmark Rooftop Units 50 HZ Bulletin No. 49045 June 208 Supersedes March 208 45.7 to 88 kw (3 to 25 Ton) Net ing Capacity - 38. to 68.6 kw (30 000 to 234

More information

K-Series Rooftop Units 50 HZ

K-Series Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC KG K-Series Rooftop Units 50 HZ Bulletin No. KG-56-300-50HZ (2/207) 45.7 to 88 kw (3 to 25 Ton) Net ing Capacity - 38. to 68.6 kw (30 000 to 234 000 Btuh) Gas

More information

Landmark Rooftop Units 50 HZ

Landmark Rooftop Units 50 HZ P R O D U C T S P E C I F I C AT I O N S P A C K A G E D H E A T P U M P KH Landmark Rooftop Units 50 HZ Bulletin No. 49049 March 202 Supersedes November 20 52.8 and 70.3 kw (5 and 20 Tons) Net Cooling

More information

Z-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

Z-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC ZG Z-Series Rooftop Units 60 HZ Bulletin No. ZGA/ZGB-092-50 (8/208) MODEL NUMBER IDENTIFICATION Brand/Family Z = Z Series Unit Type G = Packaged Gas Heat w/

More information

K-Series Rooftop Units Standard and High Efficiency - 60 HZ

K-Series Rooftop Units Standard and High Efficiency - 60 HZ PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP KH K-Series Rooftop Units Standard and High Efficiency - 60 HZ Bulletin No. KH-09-50 (/07) MODEL NUMBER IDENTIFICATION Brand/Family K = K-Series Unit Type H =

More information

Z-Series Rooftop Units 50 HZ

Z-Series Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric ZH Z-Series Rooftop Units 50 HZ Bulletin No. ZHA-036-060-50HZ (05/207) 0.5 to 2.0 kw (3 to 6 Tons) Net ing 9. to 7.3 kw (3 200 to 59 000 Btuh) Net 8.5

More information

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC KG K-Series Rooftop Units 60 HZ Bulletin No. KGA-092-50 (9/204) ASHRAE 90. COMPLIANT 7.5 to 2.5 Tons Net Cooling Capacity 86,000 to 38,000 Btuh Gas Input Heat

More information

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC KG K-Series Rooftop Units 60 HZ Bulletin No. KGA-092-50 (2/207) ASHRAE 90. COMPLIANT 7.5 to 2.5 Tons Net Cooling Capacity 86,000 to 38,000 Btuh Gas Input Heat

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP zh Rooftop Units 50 HZ Bulletin No. ZHA-092-20 (3/205) 26 to 35 kw Net ing Capacity 22.6 to 30.6 kw (77 00 to 04 600 Btuh) Net Heating Capacity 23.6 to 29.0 kw

More information

K-Series Rooftop Units Standard and High Efficiency - 60 HZ

K-Series Rooftop Units Standard and High Efficiency - 60 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric KCb K-Series Rooftop Units Standard and High Efficiency - 60 HZ Bulletin No. -04-090 (/07) MODEL NUMBER IDENTIFICATION Brand/Family K = K Series Product

More information

Landmark Rooftop Units Standard and High Efficiency - 60 HZ

Landmark Rooftop Units Standard and High Efficiency - 60 HZ PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP KH Landmark Rooftop Units Standard and High Efficiency - 60 HZ Bulletin No. 055 August 08 Supersedes June 08 MODEL NUMBER IDENTIFICATION Brand/Family K = Landmark

More information

K-Series Rooftop Units Standard Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units Standard Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP KHA K-Series Rooftop Units Standard Efficiency - 60 HZ Bulletin No. KHA-036-07 (/07) MODEL NUMBER IDENTIFICATION ASHRAE 90. COMPLIANT 3 to 6 Tons Net Cooling Capacity

More information

K-Series Rooftop Units 50 HZ

K-Series Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric KC K-Series Rooftop Units 50 HZ Bulletin No. KCA/KCB-036-090-50HZ (/206) Noal Capacity - 0.5 to 26.4 kw (3 to 7.5 Tons) Net ing Capacity 9. to 22.5 kw

More information

Z-Series Rooftop Units 60 HZ

Z-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS ZH Z-Series Rooftop Units 60 HZ Bulletin No. ZHA-036-060 (0/03) MODEL NUMBER IDENTIFICATION ASHRAE 90. COMPLIANT 3 to 5 Tons Net Cooling Capacity 36,00 to 58,000

More information

ASHRAE 90.1 COMPLIANT

ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED GAS/electric ZGB Raider Rooftop Units 60 HZ Bulletin No. 0795 November 07 Value Without Compromise MODEL NUMBER IDENTIFICATION Brand/Family Z = Raider Product Line Unit

More information

Landmark Rooftop Units 50 HZ

Landmark Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric KC Landmark Rooftop Units 50 HZ Bulletin No. 490 June 0 Supersedes September 0 0.5 to 6.4 kw (3 to 7.5 Tons) Net Cooling Capacity 9.5 to 3.7 kw (3 400

More information

Z-Series Rooftop Units 60 HZ

Z-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric ZC Z-Series Rooftop Units 60 HZ Bulletin No. ZCA-06-060 (0/0) MODEL NUMBER IDENTIFICATION to 5 Tons Net Cooling Capacity 4,600 to 57,000 Btuh Optional

More information

Energence Ultra-High Efficiency Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No

Energence Ultra-High Efficiency Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No PACKAGED ELECTRIC / ELECTRIC LCH Energence Ultra-High Efficiency Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. 20734 August 208 Supersedes July 208 5 and 20 Tons Net Cooling Capacity 80,000 to

More information

ASHRAE 90.1 COMPLIANT

ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED GAS/electric ZGA Raider Rooftop Units 60 HZ Bulletin No. 20747 November 207 Supersedes June 207 Value Without Compromise MODEL NUMBER IDENTIFICATION Brand/Family Z = Raider

More information

Landmark Rooftop Units 50 HZ

Landmark Rooftop Units 50 HZ P R O D U C T S P E C I F I C AT I O N S P A C K A G E D H E A T P U M P KH Landmark Rooftop Units 50 HZ Bulletin No. 49048 November 200 Supersedes August 200 26 to 44 kw Net Cooling 23.6 to 36.5 kw (80

More information

ROOFTOP UNITS 60 HZ P A C K A G E D H E A T P U M P

ROOFTOP UNITS 60 HZ P A C K A G E D H E A T P U M P E N G I N E E R I N G D A T A P A C K A G E D H E A T P U M P TH ROOFTOP UNITS 60 HZ Bulletin No. THA024 030 036 048 060 (08/09) ASHRAE 90.1 COMPLIANT 2 to 6 Tons Net 24,000 to 71,000 Btuh Net Heating

More information

E-Series Rooftop Units 50 HZ

E-Series Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC / ELECTRIC LCH E-Series Rooftop Units 50 HZ Bulletin No. LCH-56-300-50HZ (4/206) 45.7 to 88 kw (3 to 25 Ton) Net ing Capacity - 38. to 68 kw (30 000 to 232 000

More information

T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ

T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ PRODUCT SPECIFICATIONS AIR HANDLERS TA T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ Bulletin No. TAA-07-40 (05/015) 180-40 Models 07-090-10-150 Models Nominal Capacity - 6 to 0 Tons Optional

More information

K-Series Rooftop Units Standard and High Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units Standard and High Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP KHB K-Series Rooftop Units Standard and High Efficiency - 60 HZ Bulletin No. KHB-04-074 (/07) ASHRAE 90. COMPLIANT to 6 Tons Net Cooling Capacity,000 to 68,000

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

ROOFTOP UNITS 60 HZ P A C K A G E D E L E C T R I C / E L E C T R I C

ROOFTOP UNITS 60 HZ P A C K A G E D E L E C T R I C / E L E C T R I C E N G I N E E R I N G D A T A P A C K A G E D E L E C T R I C / E L E C T R I C tc ROOFTOP UNITS 60 HZ Bulletin No. TCA090 102 120 150 (08/09) ASHRAE 90.1 COMPLIANT 7.5 to 12 Tons Net 90,000 140,000 Btuh

More information

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA (5/2013)

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA (5/2013) PACKAGED GAS/electric KG K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA-04-090 (5/03) MODEL NUMBER IDENTIFICATION Brand/Family K = K Series Product Line Unit Type G = Packaged Gas

More information

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED GAS/electric KG K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA/KGB-04-090 (/06) ASHRAE 90. COMPLIANT to 7.5 Tons Net Cooling Capacity 4,00 to 90,000 Btuh Gas Input Heat Capacity

More information

Z-Series Rooftop Units 60 HZ

Z-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED GAS/electric ZG Z-Series Rooftop Units 60 HZ Bulletin No. ZGA-036-060 (02/203) MODEL NUMBER IDENTIFICATION Brand/Family Z = Z-Series Unit Type G = Packaged Gas Heat w/ Electric

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Landmark Rooftop Units Standard and High Efficiency - 60 HZ PRODUCT SPECIFICATIONS

Landmark Rooftop Units Standard and High Efficiency - 60 HZ PRODUCT SPECIFICATIONS PACKAGED GAS/electric Landmark Rooftop Units Standard and High Efficiency - 60 HZ PRODUCT SPECIFICATIONS Bulletin No. 0786 January 08 Supersedes December 07 ASHRAE 90. COMPLIANT to 7.5 Tons Net Cooling

More information

Energence Ultra-High Efficiency Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

Energence Ultra-High Efficiency Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED ELECTRIC / ELECTRIC LCH Energence Ultra-High Efficiency Rooftop Units 60 HZ Bulletin No. 0686 March 09 Supersedes July 08 MODEL NUMBER IDENTIFICATION Brand/Family L = Energence

More information

K-Series Rooftop Units Dual-Fuel - High Efficiency - 60 HZ

K-Series Rooftop Units Dual-Fuel - High Efficiency - 60 HZ PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP KD K-Series Rooftop Units Dual-Fuel - High Efficiency - 60 HZ Bulletin No. KD-04-060 (/07) MODEL NUMBER IDENTIFICATION Brand/Family K = K-Series Product Line Unit

More information

Packaged L Series LCA/LGA/LHA

Packaged L Series LCA/LGA/LHA Packaged L Series LCA/LGA/LHA 80, 0, 40 & 300S Models LCA/LGA 5-5 Ton LHA 5 & 0 Ton 60,000-470,000 Btuh Gas Heating Cap. 88,000-0,000 Heat Pump Heating Cap. 38,600-307,00 Btuh Optional Electric Heat GUK

More information

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS AIR CONDITIONERS ELS T-SERIES COMMERCIAL SPLIT SYSTEMS R-40A - 60 HZ Bulletin No. ELS-072-240 (2/208) P R O D U C T S P E C I F I C AT I O N S 072-090 Models 80-240 Models EER up to 2.0 6 to 20 Tons Cooling

More information

K-Series Rooftop Units 50 HZ

K-Series Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED GAS/electric KG K-Series Rooftop Units 50 HZ Bulletin No. KGA/KGB-036-090-50hz (2/207) Noal Capacity - 0.5 to 26.4 kw (3 to 7.5 Ton) Net ing Capacity - 9. to 22.5 kw (3

More information

ELITE COMMERCIAL SPLIT SYSTEMS UPFLOW/HORIZONTAL - R-410A - 60 HZ

ELITE COMMERCIAL SPLIT SYSTEMS UPFLOW/HORIZONTAL - R-410A - 60 HZ PRODUCT SPECIFICATIONS AIR HANDLERS ELA ELITE COMMERCIAL SPLIT SYSTEMS UPFLOW/HORIZONTAL - R-40A - 60 HZ Bulletin No. 20806 February 208 80-240 Models 072-090-20-50 Models Nominal Capacity - 6 to 20 Tons

More information

T CLASS ROOFTOP UNITS 60 HZ

T CLASS ROOFTOP UNITS 60 HZ E N G I N E E R I N G D A T A P A C K A G E D G A S / E L E C T R I C TG T CLASS ROOFTOP UNITS 60 HZ Bulletin No. 210444 July 2008 Supersedes February 2008 ASHRAE 90.1 COMPLIANT 2 to 6 Tons Net 23,400

More information

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature TCA ROOFTOP UNITS Service Literature TCA 180 210 240 300 (10 08) The TCA180S, 180H, 210S, 210H, 240S, 240H and 300S are available in one cabinet size with cooling capacities from 180,000 to 286,000 Btuh

More information

T A A 120 S 4 D - 1 M

T A A 120 S 4 D - 1 M PRODUCT SPECIFICATIONS AIR HANDLERS TA T-CLASS SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 50 HZ Bulletin No. 490133 February 2013 Supersedes December 2010 180-240 Models 072-090-120-150 Models Noal

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

T CLASS ROOFTOP UNITS 60 HZ Bulletin No July 2008 Supersedes August 2007

T CLASS ROOFTOP UNITS 60 HZ Bulletin No July 2008 Supersedes August 2007 E N G I N E E R I N G D A T A P A C K A G E D G A S / E L E C T R I C TG T CLASS ROOFTOP UNITS 60 HZ Bulletin No. 210392 July 2008 Supersedes August 2007 MODEL NUMBER IDENTIFICATION ASHRAE 90.1 COMPLIANT

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C P A C K A G E D E L E C T R I C / E L E C T R I C 2SA13 60HZ E N G I N E E R I N G D A T A Bulletin No. 210454 August 06 Supersedes July 06 MODEL NUMBER IDENTIFICATION SEER 13.00 2 to 2.5 Tons Capacity

More information

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Three Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

Factory Option Codes L M E S P R D V F F H E

Factory Option Codes L M E S P R D V F F H E I N D O O R A I R Q U A L I T Y P R O D U C T S P E C I F I C AT I O N S ENERGY RECOVERY SYSTEM FOR L-SERIES ROOFTOP UNITS - 60 HZ Bulletin No. 10533 January 011 Supersedes October 010 800 to 600 cfm Capacity

More information

ELITE Series R-410A - Upflow / Horizontal

ELITE Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX7UH ELITE Series R-0A - Upflow / Horizontal Bulletin No. 08 March 0 Supersedes October 0 Nominal Capacity -. to Tons Optional Electric Heat -. to kw MODEL NUMBER

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

TCA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

TCA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents TCA ROOFTOP UNITS Service Literature TCA 024 030 036 048 060 072 (10 08) The TCA packaged electric cooling units are available in basic cooling efficiency (036B, 048B and 060B) and standard cooling efficiency

More information

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained heating and cooling units

More information

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION P R O D U C T S P E C I F I C AT I O N S I N D O O R A I R Q U A L I T Y ERV ENERGY RECOVERY VENTILATOR 60 HZ Bulletin No. 20245 March 200 Supersedes April 2009 Indoor / Outdoor 500 to 0,000 cfm Capacity

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained cooling units

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can

More information

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M AIR CONDITIONERS ELS ELITE COMMERCIAL SPLIT SYSTEMS R-40A - 50 HZ Bulletin No. 49073 March 208 P R O D U C T S P E C I F I C AT I O N S Supersedes February 208 072-090 Models 80-240 Models 2 to 70 kw ing

More information

Packaged L Series LCA/LCC GUK

Packaged L Series LCA/LCC GUK Packaged L Series LCA/LCC 090, 102, 1 & 150 Models 7 1/2 to 12 Tons 7.5 to Optional Electric Heat GUK FEATURES Down flow or horizontal supply and return configuration E.T.L. and CSA listed, efficiency

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GN Series Single Packaged Gas/Electric Units with R-410A R6GN 10.8 EER Commercial System 12½ and 15 Ton Units These units offer flexibility in the replacement market. The 12½

More information

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS P6SD Series The P6SD Series packaged units are high efficiency self contained cooling units that can be installed on a roof or on a slab. The convertible unit design makes installations

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower TECHNICAL SPECIFICATIONS R6GF Series Rev B Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower R6GF 15 SEER, 81% AFUE 2-5 Ton Units These single packaged gas/electric systems

More information

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

MERIT Series R-410A - Upflow / Horizontal - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model P6SD Series M120 Product Line Single Packaged Air Conditioning, 13 SEER - R-410A, 3, 4 and 5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability

More information

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Submittal Data Form Job Name DCG Series 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Cooling Capacity: 88,000 144,000 BTU/h Heating Capacity (Output): 168,000 BTU/h Purchaser Order No.

More information

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units TM TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

GR4GA Series Single Packaged Gas/Electric Units

GR4GA Series Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS GR4GA Series Single Packaged Gas/Electric Units GR4GA 10 SEER, Three Phase, 208/230V, 460V, 575V 3 Ton thru 5 Ton Units The GR4GA Series single packaged gas/electrics are high

More information

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility

More information

K-SERIES COMMERCIAL PACKAGED ROOFTOP UNITS 2- TO 25-TON KG/KC/KH MODELS UP TO 16.5 SEER, 14.8 IEER AND 13.0 EER

K-SERIES COMMERCIAL PACKAGED ROOFTOP UNITS 2- TO 25-TON KG/KC/KH MODELS UP TO 16.5 SEER, 14.8 IEER AND 13.0 EER K-SERIES COMMERCIAL PACKAGED ROOFTOP UNITS 2- TO 25-TON KG/KC/KH MODELS UP TO 16.5 SEER, 14.8 IEER AND 13.0 EER PRECISE. VERSATILE. SOLID. K-Series rooftop units are known for precise, dependable performance.

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS TECHNICAL GUIDE CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL York s Champion package units are designed to

More information

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6) ENGINEERING DT PCKGED HET PUMPS CHP16 024 030 036 048 060 CHP20 036 048 060 2 to 5 Ton (7.0 to 17.6 ) SEER up to 12.65 Net Capacity 23,800 to 59,000 Btuh (7.0 to 17.3 ) Heating Capacity 23,800 to 56,000

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

Typical Applications. Horizontal Installation

Typical Applications. Horizontal Installation ENGINEERING DATA COILS COIL UNITS CB19 AND CBH19 SERIES UP-FLOW, DOWN-FLOW AND HORIZONTAL COIL UNITS *12,600 to 65,500 Btuh (3.7 to 19.2 kw) Cooling Capacity 11,500 to 60,000 Btuh (3.4 to 17.6 kw) Heat

More information

GR4GC Series Single Packaged Gas/Electric Units

GR4GC Series Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS GR4GC Series Single Packaged Gas/Electric Units GR4GC 12 SEER, Three Phase 3 Ton thru 5 Ton Units The GR4GC Series single packaged gas/electrics are high efficiency self contained

More information

Q4SE Series Single Packaged Heat Pump, Single Phase

Q4SE Series Single Packaged Heat Pump, Single Phase TM TECHNICAL SPECIFICATIONS Q4SE Series Single Packaged Heat Pump, Single Phase Q4SE-14 SEER 2-5 Ton Units Cooling: 23,600 to 56,500 Btuh Heating: 22,200 to 55,500 Btuh The Q4SE Series single packaged

More information

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS DF6SF Series Rev B Two-Stage Heat/Two-Stage Cool with Variable Speed Blower ihybrid Dual Fuel Package Units DF6SF 15 SEER, 81% AFUE, 8.0 HSPF 2 Ton thru 5 Ton Units These dual

More information

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units TM TECHNICAL SPECIFICATIONS P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units The P4 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS R8HE Series Rev A Single-Phase and Three-Phase 95% AFUE Condensing Exchanger offering Two-Stage ing and 14 SEER Single-Stage Cooling with ECM Blower These single packaged gas/electric

More information

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353

More information

ENERGY RECOVERY SYSTEM 60 HZ

ENERGY RECOVERY SYSTEM 60 HZ I N D O O R A I R Q U A L I T Y E N G I N E E R I N G D A T A ENERGY RECOVERY SYSTEM 60 HZ Bulletin No. 210517 April 2008 Supersedes 210368 April 2007 300 to 6200 cfm Capacity MODEL NUMBER IDENTIFICATION

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information