1 Machine, Panel, and Plant Level Solutions Mark Stephens, PE Manager Industrial Studies Electric Power Research Institute 942 Corridor Park Blvd Knoxville, Tennessee Phone
2 Cost of Solutions Versus Knowledge of Sensitivity 2
3 Example PQ Solution Levels Machine or Subsystem Level Power Conditioning Control Level Power Conditioning (1/10 th to 1/20 th of Machine Level Power Conditioner Cost) Control Level Embedded DC Solution (Best done by OEM in design phase) 3
4 Technologies Covered Pro DySC (larger version of MiniDySC) Eaton SRT/Omniverter AVC Active Power Flywheel (a.k.a CAT UPS) Pentadyne Flywheel Static Transfer Switch DVR Beckwith Digital Motor Bus Transfer System 4
5 Example PQ Solution Levels Machine or Subsystem Level Power Conditioning Control Level Power Conditioning (1/10 th to 1/20 th of Machine Level Power Conditioner Cost) Control Level Embedded DC Solution (Best done by OEM in design phase) 5
6 Dynamic Sag Corrector MegaDySC Draws power from remaining sagged voltage down to 50% of nominal voltage, and injects a series voltage to regulate a sinusoidal output voltage Below 50%, draws power from internal storage capacitors Mega and Pro DySC have on board event logging. Three-Phase Protection Amps ProDySC Three-Phase Protection Amps MiniDySC Single-Phase Protection 1-50 Amps 6
7 Example DySC Output Input Voltage (Van) t (s) Missing Volts t (s) DySC Output Voltage t (s) 7
8 Voltage Sag Correction & Ride-Through Times Ride-Through Times: (Based on 100% load, 0.7PF at 60Hz line frequency) Standard Runtime: 2 seconds for sags from 87% to 50% of nominal voltage every 60 seconds Up to 5 seconds coverage on Extended Run-Time Models 3 cycles for Standard Outage units from 50%-100% (zero voltage remaining) 12 cycles for Extended Outage units from 50%-100% (zero voltage remaining) 8
9 Extended Run-Time Models Are Available 9
10 Extended Run-Time Models Are Available 10
11 Example DySC Bypass Configuration 11
12 Example DySC Pricing Type Part Number Current Cost ProDySC 480Vac, Standard Outage Panel Mount 3-Wire 18-21kVA DS30025A480V3SH2000B 25A $17, ProDySC 480Vac, Standard Outage Panel Mount 3-Wire 36-42kVA DS30050A480V3SH2000B 50A $23, ProDySC 480Vac, Standard Outage Floor Mount 3-Wire 73-83kVA DS30100A480V3SH2000B 100A $40, ProDySC 480Vac, Standard Outage Floor Mount 3-Wire 165kVA DS30200A480V3SH2051A 200A $58, MegaDySC 480Vac, Standard Outage Floor Mount 3-Wire 333kVA DS30400A480V3SH2000A 400A $103,
13 Omniverter AVC Voltage 208,480 or 600V standard with 400/690V options available at 50/60 Hz. Sag correction 30 and 40% (SEMI F47) 13
14 Omniverter Active Voltage Conditioner Inverter controlled power conditioning for high power applications 25 kva to 5 MVA at Low Voltage and 1 MVA to 50 MVA + at Medium Voltage 2-36kV The AVC is a 3 phase device and corrects voltages Line to Line. The AVC is a LOAD dedicated device and as a standard does not provide correction back to the supply 14
15 Single Phase Schematic 15
16 How Does The AVC Work? The AVC consists of an inverter which feeds an injection transformer connected in series with the utility supply. The inverter produces compensating voltage vectors which correct for utility voltage disturbances (sags, imbalance, flicker, voltage harmonics and optionally overvoltages, etc). For Medium Voltage (MV) applications add a rectifier transformer and change voltage ratio on injection transformer Should the AVC require energy to provide correction it draws this power from its rectifier. There are NO storage devices in the AVC NO back feed of any upstream fault 16
17 Key Features Fast response <1msec to initiate correction Complete correction to ±1% in 8msec (< 1/2 cycle) Continuously variable control (no step changes in output) Very efficient (typically > 98.5%) A modern microprocessor controlled solution High reliability through the use of redundant static switch back-up and Maintenance Bypass. 17
18 AVC is an ON LINE Device Unlike most of its competitive devices, which start correction at a predetermined voltage threshold, the AVC is continuously ON LINE It can maintain voltage within ± 1% of nominal It can provide continuous correction in the event of a prolonged under-voltage It can correct multiple sag events occurring in rapid succession It also corrects other voltage problems 18
19 Benefits of On-line Operation Corrects multiple sequential events Does not feed line faults as no storage Continuous phase balancing Flicker & voltage harmonic correction Optional 3-phase over-voltage correction, single phase OV correction standard No resonance with downstream capacitance 19
20 AVC Sag correction & Power conditioner Actual voltage sag event showing AVC input (top) and output (bottom) Before After AVC 20
21 3- phase sag to 70% 21
22 3- phase sag to 60% 22
23 Single phase 50% sag for 130mS 23
24 Example Control Level Solutions at the Distribution Panel and Recommendations Sometimes the most effective solution is to provide conditioned power for the entire IPP Panel. Advantages of this approach include: Simplified Cut Over/Fewer Touch Points Single Power Conditioner for many loads When sized to support kva of transformer, this approach will support future expansion in panels 24
25 Example Measured Loading of IPP Panel Panel Lightly Loaded Several Spare CB in Panel 480Vac CB Rating is 50A 480Vac Phase Currents Phase A 4.89A Phase B 4.11A Phase C 1.67A Measurements were taken when line was running. It is possible that some loads could be cycled off. 25
26 Example Three Phase Solution ProDySC The Dynamic Sag Corrector from Softswitching Technologies Deep Sag Coverage especially when lightly Loaded Has Capacitors that allow for some ride-through for interruptions 26
27 Example Three Phase Solution AVC Three-Phase Correction to 50% Single-Phase Correction to 25% No capacitors, therefore no deep sag or interruption ride-through Less Expensive than DySC 27
28 CAT UPS
29 Active Power/CAT UPS Solution Diesel Genset For continuous power after seconds CLEANSOURCE CS 600 On-line Temperature: OK Current: OK Voltage: OK Battery: OK UPS Critical Load Utility Power DC Flywheel UPS 29
30 CAT UPS 250kW/300kVA unit costs in the range of $100k-$140k depending upon accessories and options. Flywheel speed 8000 RPM. In recent years there has been a number of installations in US for bridge power application; provides 15 second protection under rated load condition. 30
31 Flywheel System One-line DC Buss IGBT Inverter Motor, Generator To UPS Battery Input & Flywheel Energy Storage Flywheel Sensors Field Drive Bearing Drive DC Monitoring IGBT Control AC Monitoring Control and System Monitoring Comm 120 VAC Flywheel Sensors: Over speed Over voltage Over temperature Vibration Local EPO 31
32 Flywheel During Discharge DC Buss IGBT Inverter Motor, Generator To UPS Battery Input & Flywheel Energy Storage Flywheel Sensors Field Drive Bearing Drive DC Monitoring IGBT Control AC Monitoring Control and System Monitoring Comm 120 VAC Flywheel Sensors: Over speed Over voltage Over temperature Vibration Local EPO 32
33 Flywheel During Recharge or Float DC Buss IGBT Inverter Motor, Generator To UPS Battery Input & Flywheel Energy Storage Flywheel Sensors Field Drive Bearing Drive DC Monitoring IGBT Control AC Monitoring Control and System Monitoring Comm 120 VAC Flywheel Sensors: Over speed Over voltage Over temperature Vibration Local EPO 33
34 Integrated Motor/Generator/Flywheel Magnetic bearing integrated into field circuit Ball bearings easily replaced One moving part (rotor) Removable cartridge armature Simple, Reliable, and Power-dense 34
35 The Cat UPS Family UPS 300 UPS 300E 480Vac, 60Hz UPS 600 UPS
36 Continuous Power System Auto Transfer Switch Non-Critical Load From Utility Cat UPS Parallel On-Line Cat Gen Set Redundant 24 VDC Starting Power Critical Load 36
37 Dynamic Voltage Regulation +10% Nominal Voltage RMS Voltage sampled every 5 cycles +2% -2% -10% 37
38 CAT UPS Performance from Test in EPRI Lab 38
39 Pentadyne Flywheel
40 What is it? The Pentadyne Voltage Support Solution is a flywheel-based energy storage system. It operates as a mechanical battery that stores energy in the form of a rotating mass. This energy is immediately converted to useful power when needed. 40
41 Pentadyne VSS+DC A short duration energy storage device that can supplement or completely eliminate the need for lead-acid batteries in UPS applications. If used as the sole source of energy storage it vastly improves reliability, longevity and uptime availability. It can change downtime maintenance from many hours, many times per year to a single one-hour interval once every six years. 41
42 What Can It Do? Configured as a two-terminal DC system Used as a functional replacement for a bank of chemical batteries used with Uninterruptible Power Supply Systems (UPSs) VSS+DC can work in parallel with a bank of chemical batteries for increased DC bus reliability and redundancy It receives recharge and float power from the two-terminal DC bus and returns power to the same DC bus whenever the voltage droops below a programmable threshold level Multiple VSS+DC units can be put in parallel for higher power output, longer ride-through duration and/or redundancy. Can be used in many DC applications to provide power quality or energy recycling. Designed not to require major service for 20 years in a UPS application. 42
43 Features and Benefits 43
44 Possible Setups 44
45 Performance Chart 45
46 Typical Modes of Operation 46
47 Technology Comparisons Pentadyne: (Also marketed as Liebert FS) Requires separate UPS unit that is sold in package Magnetically levitated flywheel, no bearings No Vacuum Pump (factory sealed flywheel) 50lb flywheel Spins at 52,000 RPM 190KW for 10+ Seconds One unit size Flywheel standby is 250W Maintenance: Operation check in first 6 months Service every 6 yrs, approximately $1,500 per flywheel. Yearly maintenance contract price is $460 per year per flywheel. Active Power /CAT UPS: UPS is integrated into package electronics Bearing On Board Vacuum Pump Included in system 800lb flywheel Spins at 8,000 RPM 150,300,600,900kW for 10+ seconds - Multiple sizes Flywheel standby power is about 2500W Maintenance: Air filters as needed Vac pump oil, six ounces once a year Major Maintenance every 3 to 4 years, $6,357 dollars per unit for bearing change 47
48 Static Transfer Switch Solid State thyristor or GTO switches transfer between independent distribution sources for interruptions and sags 1/4 to 1/2 cycle response medium voltage, 600 A no energy storage electronics require cooling ~ $350k to $700k each 48
49 Series Voltage Boost Devices Synthesizes missing part of waveform Medium voltage applications, up to 40 MVA May contain energy storage, usually DC capacitors Ride-thru for 0.2 to 1.0 sec 1/4 cycle response Up to 60% boost ~$600K per boost MVA 49
50 Beckwith Digital Motor Bus Transfer System (MBTS) This is an interruption protection scheme not a voltage sag ride-through solution. The Beckwith Digital Motor Bus Transfer System (MBTS) M is used to transfer between two plant feeders. This switch can provide inphase switching between the back-emf from the plant and the alternate feeder. 50
51 MBTS Standard Features of Automatic Transfer The system provides the following Automatic Transfer logic and features: Transfer initiated by protective relay external to the MBTS Automatic Transfer after a loss of the motor bus supply voltage based on the programmable undervoltage element. This provides a selectable backup feature if a manual or protective relay transfer is not initiated. Fast Transfer with adjustable phase angle limit In-Phase Transfer at the first phase coincidence if Fast Transfer is not possible Residual Voltage Transfer at an adjustable low residual voltage limit if Fast Transfer and In-Phase Transfer are not possible Fixed Time Transfer after an adjustable time delay Programmable Load Shedding with no time delay for Fast Transfer Programmable load shedding prior to initiating In-Phase Transfer, Residual Voltage Transfer, and Fixed Time Transfer Adjustable setpoints for delta voltage limit and delta frequency limit Verify the new source (the source to which the bus is being transferred) is healthy and within acceptable 51
52 There are two options of the MBTS $9450 List price for M-4272 switch alone. 52
53 MBTS Sequence of Transfer Logic in Sequential Transfer Mode Open Breaker on side with Faulted Feeder 53
54 Glide Trajectory Estimation of Residual Voltage During an Interruption Examining the response of the plant when a voltage interruption occurred when the Incoming Circuit Breaker (ICB) opens. We will examine how long it take to reach various voltage levels 80% Level (Trip AB PLC-5) 70% Level (Trip AC ice cubes ) 50% Levels (SEMI F47 level) 25% Level (Level Required for 0% Level (complete spin down) 54
55 Glide Trajectory Estimation of Residual Voltage 55
56 Example Glide Trajectory Estimation of Residual Voltage at a Plant Residual Voltage 100% 90% 80% % Residual Voltage 70% 60% 50% 40% 30% 20% 10% 0% Cycles 56
57 MBTS Transfer Estimates at a Plant The MBTS will attempt to transfer in fast transfer first. If this does not work it will do either Delayed In- Phase or Residual Voltage Transfer. With the low Inertia load of the Example Plant Load, the order of operation that the MBTS will attempt is most likely 1) Fast Transfer 2) Residual Voltage Transfer when voltage is less than 25% 3) Delayed-in-Phase Transfer (may never happen in Plants scenario) 57
58 Example Transfer Time Based on Example Plant Scenario 1.0 Fast Transfer Scenario 100% % Residual Voltage 90% 80% 70% 60% Residual Voltage 50% Fast Transfer Min (est.) Fast Transfer Max (est.) 40% 30% 20% 10% 0% Cycles 3.0 Delayed-in-Phase Transfer Scenario 100% 90% % Residual Voltage 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 2.0 Residual Voltage Transfer Scenario Residual Voltage Residual Voltage Transfer Scenario Min (est.) Residual Voltage Transfer Scenario Max (est.) % Residual Voltage 80% 70% 60% 50% 40% 30% 20% 10% 0% Residual Voltage Delayed In Phase Transfer Min (est.) Delayed In Phase Transfer Max (est.) 0% Cycles Even in Best Case Scenario, plant would still need either SEMI F47 Compliant Equipment or power conditioning on Control Circuits! Cycles 58
Standby Power Systems
Source: Power Quality in Electrical Systems Chapter 13 Standby Power Systems The term standby power systems describes the equipment interposed between the utility power source and the electrical load to
More informationSurabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality
Surabaya Seminar 2014 Ferdinand Sibarani, Surabaya, 30 th October 2014 Power Quality Content 1. Power quality problems 2. ABB s low voltage (LV) solution PCS100 AVC (Active Voltage Conditioner) PCS100
More informationTECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
More informationModel ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase
Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible
More informationPOWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)
TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)
More informationPOWER kva
TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power
More informationPower Protection Discrete Automation & Motion South Africa
Carel Oberholzer, ABB South Africa, May 2013 PCS100 Power Protection Discrete Automation & Motion South Africa May 13, 2013 Slide 1 Power Protection Agenda 1. Introduction of power protection 2. Overview
More informationGE Industrial Solutions ES Group / UPS Solutions. GE Flywheel UPS. Flywheel Energy. An Integrated Solution
GE Industrial Solutions ES Group / UPS Solutions GE Flywheel UPS Flywheel Energy Using An Integrated Solution Key Drivers that Makes GE Flywheel UPS Attractive Low Total Cost of Ownership / Flywheel 20
More informationExpect More From An Energy Storage Solution BATTERY FREE DC ENERGY STORAGE FOR UPS BILL WOLFE NORTHEAST REGIONAL MANAGER
Expect More From An Energy Storage Solution BATTERY FREE DC ENERGY STORAGE FOR UPS BILL WOLFE NORTHEAST REGIONAL MANAGER DC Energy Storage - ReGen Energy Re-cycle Markets / Applications Energy Re-cycling
More informationVOLTAGE SAGS; A LITTLE STORAGE CAN GO A LONG WAY
WHITE PAPER VOLTAGE SAGS; A LITTLE STORAGE CAN GO A LONG WAY I. Utility power in the U.S. is very reliable; we count on it to be there, expect it to be there, and it usually is. Barring natural disasters
More informationPOWER kva
+44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw
More informationMKN-DSP SERIES - THREE PHASE
Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /
More informationBATTERY FREE DC ENERGY STORAGE FOR UPS. Yorba Linda CA (714)
BATTERY FREE DC ENERGY STORAGE FOR UPS Yorba Linda CA (714) 386-03800 Expect More From An Energy Storage Solution VYCON s VDC DC Flywheels VYCON s VDC/XE flywheel system stores and delivers reliable DC
More informationPower Systems Trainer
Electrical Power Systems PSS A self-contained unit that simulates all parts of electrical power systems and their protection, from generation to utilisation Key Features Simulates generation, transmission,
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationPOWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting
POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running
More informationTheory of Operation: Low Speed Flywheel
Theory of Operation: Low Speed Flywheel White Paper 106 2128 W. Braker Lane, BK12 Austin, Texas 78758-4028 www.activepower.com Objective This paper will review the concept and operation of a flywheel system
More informationFlywheel UPS Systems, kva
GE Industrial Solutions Flywheel UPS Systems, 50-1000 kva using TLE or SG Series UPS Incorporating Flywheel Technology Growing Need for Flywheel UPS Systems Popular Market Segments Numerous applications
More informationABB Data Center Solutions Day 5 July 2013 by Kelvin Sim Myths or Truths: Achieving 99% Efficiency with Single Conversion Backup Power System
ABB Data Center Solutions Day 5 July 2013 by Kelvin Sim Myths or Truths: Achieving 99% Efficiency with Single Conversion Backup Power System Striking the right balance The Data Centre Backup Power / UPS
More informationIlluminator Series CR NEMA 3R
Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the
More informationDC POWER SUPPLY SYSTEMS
DC POWER SUPPLY SYSTEMS double branch Rectifier - SCR type TITANIUM 2R-SCR PLUS SERIES TITANIUM 2R-SCR rectifier series belongs to the Double Branch category thus provided with two independent AC / DC
More informationTechnical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER
Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationTECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III
TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III 1. SCOPE A. The Central Lighting Inverter shall be a solid-state three phase system designed to provide
More informationTECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)
TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5
More informationPowerware Master Modbus
Powerware Master Modbus Map 164201391 Rev D This document describes the format of the data contained in the Modbus messages. Not all registers apply to all UPS modules. Please consult the individual UPS
More informationTECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)
TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5
More informationEFFEKTA Power Supplies
EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power
More informationSS SyStem SyStemy free UPS tter ba UPS
UPS battery free UPS systems www.ctm.it CleanSource HD 625 Flywheel Technology SYSTEM FEATURES Rugged, on-line & fault-tolerant UPS Highly efficient UPS architecture Handles multi-load characteristics
More informationPowerValue 11/31 T kva
Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power
More informationTechnical Data Sheets
GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01
More informationAPC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply
APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous
More informationSmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT20KX Highlights On-line double-conversion topology, VFI operation
More information.3 Section Waste Management and Disposal.
Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section
More informationProduct Specifications
Product Specifications Guide Specification for FirstLine 10Kva, 15Kva, and 20Kva Three-Phase, On-Line Uninterruptible Power Supply 4-15-10 301 Gaddis blvd, Dayton, OH 45403, USA Telephone: (866) 261-2257,
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationPower stability for manufacturers
ARTICLE Power stability for manufacturers Manufacturing is a critical aspect of many economies. However, many places lack power grid stability, which leads to production disruption. ABB s PCS100 family
More informationn Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99
80-125 kva/kw E Three-Phase Double-Conversion On-Line Full Four Year Warranty www.stacoenergy.com Up to 99% Efficient n Lower energy costs and carbon footprint Compact & Reliable n Requires either front,
More informationLiebert FS Flywheel DC Energy Storage System
AC Power For Business-Critical Continuity Liebert FS Flywheel DC Energy Storage System Reliable Battery-Free Solution For Use With UPS Systems Liebert gives you a whole new way to look at energy storage
More informationMaster Plus kva
Local Area Networks (LAN) ServerS Data Centers Telecommunication devices e-business (Servers Farms, ISP/ASP/POP) Industrial Processes Industrial PLCs Electromedical Devices Emergency Devices (lights/alarms)
More informationABB UPS 3. November 2014
ABB UPS 3. November 2014 Modular Architectures Centralized Parallel Architecture (CPA) In a Centralized Parallel Architectures the system is composed of common system building blocks: MAINS 1 MAINS 2 CENTRAL
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series
More informationSmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS
SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS MODEL NUMBER: S3M60KX Highlights Best-in-class footprint and power density minimize space requirements for up to 60kVA
More informationPowerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)
A Complete solution for small battery-backed dc instrument power systems. DATASHEET Supply 12Vdc 8A or 24Vdc 6A loads Ideal for RTU s, dataloggers, remote field instrumentation, alarm systems, etc. where
More informationTECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008
NB Power Customer Service and Distribution June 2008 Prepared by: Steven Wilcox Revised by: Steven Wilcox TABLE OF CONTENTS 1.0 Introduction 4 2.0 NB Power Policy on Independent Power Production 4 3.0
More informationStatic frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids
Static frequency converter couples US paper mill s 2-Hz and 0-Hz electricity grids Before 0 Hz was adopted as the standard frequency for electricity distribution in the USA, power companies across the
More information10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph
VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery
More informationMedium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.
Medium Voltage Power Factor Correction Reactive Compensation Harmonic Filters POWER QUALITY Electrical Power Quality Management at its best. From electricity generation, transmission, thru its distribution
More informationVYCON Direct Connect (VDC ) Kinetic Energy Storage Systems
VYCON Direct Connect (VDC ) Kinetic Energy Storage Systems The Optimal UPS Energy Storage Solution for Mission-Critical Power Protection RELIABLE AND PREDICTABLE ENERGY STORAGE The VYCON kinetic energy
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply SGSE_010-040_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91
More informationTechnical Specification SENTINEL PRO
Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES
More informationABB n.v Power Quality in LV installations
ABB n.v. - 1 - Power Quality in LV installations PQ problems in LV installations 750 500 250 Volts 0-250 -500 Amps -750 3000 2000 1000 0-1000 -2000-3000 10:25:43.72 10:25:43.73 10:25:43.74 10:25:43.75
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TM SG Series 100 &120 PurePulse TM SG Series 60 & 80 PurePulse SGSE_060-120_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TM SG Series 200-250 - 300 PurePulse CE S3 TM SG Series 160 PurePulse CE S3 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)
More informationEON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems
EON Model EL3 Three Phase Centralized Emergency Lighting Inverter General Specification 40KW 55KW Systems 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements
More informationIlluminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System
Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41
More informationD Series: UPS UPTO - 300KVA - Three / Three Phase
D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction
More informationThe behavior of the cycloconverter fed gearless drive under abnormal electrical conditions
Mining The behavior of the cycloconverter fed gearless drive under abnormal electrical conditions Reprint Authors: Kurt Tischler Siemens AG, Mining Technologies, Erlangen, Germany Reprint: WORKSHOP SAG
More informationForm G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION
Form G5-1 Page 1 of 3 PACIFIC GAS AND ELECTRIC COMPANY PG&E LOG WO/GM D&C Name of Project: Location: Transmission Line No. Distance Circuit No. 1. Maintenance Data: Generation Customer s Maintenance Chief
More informationPower Quality and Protective Device Coordination: Problems & Solutions Part 1 Undersizing of Utility Main Service Transformers
Power Quality and Protective Device Coordination: Problems & Solutions Part 1 Undersizing of Main Service s INTRODUCTION by Robert E. Fuhr, P.E. The use of electronic equipment has dramatically increased
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33U Series / 10 20 30 40 50 60 kva 208 VAC UL Series 1 Date of issue: 11/05/2008 LPS33U_030-040_S1 GE_01
More informationDefender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications
Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting
More informationSmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT30K Highlights On-line double-conversion topology, VFI operation
More informationTOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS
INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...
More informationTargeted Application of STATCOM Technology in the Distribution Zone
Targeted Application of STATCOM Technology in the Distribution Zone Christopher J. Lee Senior Power Controls Design Engineer Electrical Distribution Division Mitsubishi Electric Power Products Electric
More informationVYCON Direct Connect (VDC ) Kinetic Energy Storage Systems
VYCON Direct Connect (VDC ) Kinetic Energy Storage Systems The Optimal UPS Energy Storage Solution for Mission-Critical Power Protection Innovation That Drives Industries Reliable and Predictable Energy
More informationEON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems
EON Model EL3 Three Phase Centralized Emergency Lighting Inverter General Specification 10KW 33KW Systems 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements
More informationFortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state
More informationPower Lynx 3 Uninterruptible Power System (UPS) Technical Specifications
Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible
More informationSitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004
SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004 Applications Computer and Data Centers Server Farms Process Control Broadcasting / SAT Systems Radar control installations Air traffic control
More informationAchieving the Highest Power Density in the Smallest Footprint
Achieving the Highest Power Density in the Smallest Footprint White Paper Summary For many years, mission critical applications have required high quality power conditioning and uninterruptable power to
More informationTechnical data sheets
GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company
More informationDevelopment and Operational Advantages of a Solid State Circuit Breaker with Current Limiting
Development and Operational Advantages of a Solid State Circuit Breaker with Current Limiting Breaker Technology Operational Advantages Development Schedule Dave Richardson, Ph.D.,P.E. Powell Power Electronic
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH
More informationWorld Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants
World Class Power Solutions Rectifiers For Stationary Battery Systems in Nuclear Power Plants General 2 1.1 Application Electronically controlled rectifier assemblies are used in conjunction with suitable
More informationMarketing Management Team of Europe
Emerson Network Power Liebert NXe UPS GUIDE SPECIFICATIONS For a 10 to 20 kva (50 or 60Hz) Parallelable Digital Uninterruptible Power Supply (UPS) System - 1 - Contents 1.1 SUMMARY... 3 1.2 STANDARDS...
More informationSmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation
More informationPQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads
PQC-STATCON PPHVC-Power Quality Solutions Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads Contents What is poor power quality? Reasons for investing
More informationPower Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS
Power Quality Solutions 2018 POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS ACTIVE Ematic FA40 New Series ICAR: products and solutions Founded in 1946, ICAR is a leading manufacturer of capacitors and
More informationPI144D - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE
More informationPI144J - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE
More informationDesigning and Maintaining a Pollution-Resilient Electric Power System. Managing Pollution Issues
Designing and Maintaining a Pollution-Resilient Electric Power System Tom McDermott IEEE/PES T&D Conference April 21-24, 2008 Chicago, IL Managing Pollution Issues Define the metrics, and measure them
More informationCobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications
Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System
More informationPOWER WAVE 1 SINGLE-PHASE, (3 TO 20 KVA) & (3 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER
POWER WAVE 1 SINGLE-PHASE, (3 TO 20 KVA) & (3 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER GENERAL SCOPE This guide provides technical information and specifications for OnLine Power s Power Wave 1 Central
More informationEst DCM Double Conversion Module 400kVA - 800kVA
Est.1968 DCM Double Conversion Module 400kVA - 800kVA The parallel operation of converters for increased output power or redundancy is commonplace but poses problems for large systems. A new approach is
More informationTower Electronic Systems
3300 UPS Instruction Manual AUGUST 2005 CONTENTS 1.0 INTRODUCTION 1.1 General description 3 1.2 UPS building blocks 3 1.2.1 Boost converter 3 1.2.2 Inverter 3 1.2.3 Static transfer switch 3 1.2.4 Battery
More informationCrucial Power Products
TECHNICAL GUIDE SPECIFICATIONS WAVE RIDER 1 SINGLE-PHASE, (2.1 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER 1. GENERAL 1.1 SCOPE Crucial Power Products This guide provides technical information and specifications
More informationQuestions Section: Do you have questions that aren't covered? Please contact us!
Questions Section: 1. What are the screw terminals on the back of my XP600 for? 2. How do I hook up a remote turn-on switch for my XP250 / XP600 / XP1100/ MX series inverter? 3. Can I sell power back to
More informationPhoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP
Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER
More informationTechnical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality
GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino
More informationPowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations
Standalone three-phase UPS system PowerWave 33 S3 60 120 kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations Innovative technology delivering unmatched
More informationLiebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL
1.1 SUMMARY Liebert GXT3 8000 & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements
More informationMaster DIALOG INDUSTRY RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs Emergency devices (lights/alarms) Electro-medical devices Telecommunication devices Industrial applications
More informationINDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL
Local Area NETWORKS (LAN) ServerS DATA CENTRES TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE
More informationUPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.
SENTRY HPS HM/HT provides maximum protection for vital mission-critical networks, security applications (electro-medical) and industrial applications thanks to its outstanding mechanical and electrical
More informationTOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY
CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA 4400 15/20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE
More informationCONTINUOUS POWER IN YOUR CONTROL KEM5
CONTINUOUS POWER IN YOUR CONTROL KEM5 Simply Reliable Solutions to Power Quality Issues Banks, Data Centers, Telecoms, Airports, Manufacturing Processes & Major Research Projects, in fact all installations
More information