VIKING HEAVY DUTY PUMPS SERIES 225 AND 4225 JACKETED BRACKET, STANDARD CONSTRUCTION FEATURES

Size: px
Start display at page:

Download "VIKING HEAVY DUTY PUMPS SERIES 225 AND 4225 JACKETED BRACKET, STANDARD CONSTRUCTION FEATURES"

Transcription

1 VIKING HEAVY DUTY PUMPS JACKETED BRACKET, STARD CONSTRUCTION FEATURES SERIES 5 Pumps Cutaway View GPM Sizes ( m³/hr) Section Page. Issue C MECHANICAL SEAL (SERIES 5) H - LL SIZES LS - M SIZES SEAL SETSCREW ACCESS HOLE ROTOR BRACKET 567 SHAFT Stainless Steel Retainer Stainless Steel Springs PTFE Shaft Wedge Carbon Rotating Face (Washer) 5 Stationary Seat 6 PTFE Seat Ring 7 Anti-Rotation Pins JACKETED HEAD (Standard) BRACKET FEATURES SHAFT Stainless Steel Retainer Stainless Steel Springs PTFE Shaft Wedge Carbon Rotating Face (Washer) 5 Stationary Seat 6 Seal Seat Gaskets 7 Seal Holder 8 Seal Plate RELIEF VALVE (Plain or Jacketed) (Jacketed valve shown) Jacketed head is standard with Jacketed Bracket Series 5 and 5. For over pressure protection when using a jacketed head, a jacketed relief valve should be piped into the discharge line. Jacketed relief valves on head are available for pumps of 5 to 0 GPM ( to 95 m³/hr); non-jacketed valves available for all sizes. (Note: combination of jacketed head and relief valve on head not available.) POSITIVE-LOCK THRUST CONTROL Series 5 and 5 pumps are manufactured with positive-lock thrust control for accurate axial positioning of rotor and shaft. Illustration shows bearing and double end cap arrangement. 6 Range Temperature Range Viscosity Range SERIES 5 Pumps Cutaway View GPM Sizes ( m³/hr) 00 PSI ( BAR) for 00 SSU ( cst) and above 00 PSI (7 BAR) for below 00 SSU ( cst) 0 F. to +50 F. (-8 C. to + C.) 8 SSU to,000,000 SSU (0. cp to 0,000 cst) GPM (m³/hr ) (Nominal Rating) Heavy-Duty Jacketed Bracket Pumps For Viscous Liquid Handling Problems The jacketed bracket Series 5 and 5 pumps use heavy-duty construction to tackle tough industrial jobs. The Viking positive displacement jacketed rotary pump provides an even flow when handling heavy, viscous liquids like asphalt, syrup, molasses, coal tar, soap solutions, etc. These liquids present temperature control problems, so jacketed areas at the front and back of the pumps allow preheating of the pump. Preheating is required with viscous liquids which cool down to ambient temperatures and become almost solid. Without preheating, this heavy mass can damage pumps, motors and total systems. These pumps are available with either soft packing (Series 5) or with mechanical seals (Series 5). Values shown represent minimums or maximums. Some special construction or consideration may be required before a cataloged pump can be applied to an application involving maximum pressure or minimum or maximum temperature and/or viscosity. Nominal capacities based on handling thin liquids at low pressures. Metric conversions are based on US measurements and rounded to the nearest whole number.

2 Section Page. Issue C VIKING HEAVY DUTY PUMPS UNMOUNTED PUMPS LQ, LL and LS Sizes Dimensions for Unmounted Pumps See Page.9. Performance Data for Unmounted Pumps See Pages. through.. H and HL Sizes K, KK and L Sizes Q and M Sizes Shown with jacketed relief valve CONSTRUCTION SERIES 5 and 5 ( H THROUGH M SIZES) Pump Construction Casing Head Bracket Rotor Idler Rotor Shaft And Idler Pin Shaft Sealing Packed Bushings Mechanical Seal Packed Mech. Seal Idler Bracket Idler Bracket Standard Construction Iron Iron Iron 5 Iron Iron Steel Standard PTFE Seal Bronze Bronze Carbon Graphite Carbon Graphite Steel Fitted Iron Iron Iron Steel Iron Steel Standard PTFE Seal Bronze Bronze Carbon Graphite Carbon Graphite NOTE: Relief valve cannot be used on pump with jacketed head plate or jacketed head. SPECIFICATIONS SERIES 5 and 5 UNMOUNTED PUMPS Packed Model Number Port Size Nominal Pump Rating Mech. Seal Inches GPM (m³/hr) RPM Motor HP Required At Rated Speed Pumping 00 SSU Liquid 50 PSI ( BAR) Hydrostatic Steel Fitted Construction Above This Viscosity 6 Discharge When Handling 00 SSU Liquid At Nominal Rated Speeds 00 PSI (7 BAR) PSIG (BAR) SSU (cst) PSIG Steam (Sat.) Temperature / of Fluids In Jackets PSIG (BAR) Heat Transfer Oil PSIG (BAR) Approximate Shipping Weight With Jacketed Head Pounds (KG) H5 H5 ½ 5 () 800 ½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) (9) HL5 HL5 ½ 0 (7) (8) 7,500 (,650) (85) 50 (0) 50 () 50 (0) 5 (0) K5 K5 60 () 60 7½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 0 (5) KK5 KK5 80 (8) ½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 5 (57) L5 L5 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 75 (79) LQ5 LQ5 ½ 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 90 (86) LL5 LL5 0 () 50 7½ 5 00 (8),500 (550) (85) 50 (0) 50 () 50 (0) 00 (9) LS5 LS5 00 (5) (8) 75,000 (6,500) (85) 50 (0) 50 () 50 (0) 0 (95) Q5 Q5 00 (68) (8) 7,500 (,650) (85) 50 (0) 50 () 50 (0) 80 (8) M5 M5 0 (95) (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 60 (9) Note: recommended temperature for cataloged pump is 50 F. For higher temperatures consult factory. PTFE fitted mechanical seal used in Series 5 pumps. Q size has steel idler. For mechanical seal pumps on applications with viscosities greater than 5,000 SSU (5,500 cst) anytime during operating cycle, check with factory. Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. 5 KK and LS sizes have Ductile Iron rotor. 6 For maximum recommended discharge pressures when handling other viscosities and/or at other speeds, see performance curves. If suction pressure exceeds 50 PSIG ( BAR), consult factory. Metric conversions are based on US measurements and rounded to the nearest whole number.

3 VIKING HEAVY DUTY PUMPS Section Page. Issue B VIKING HELICAL GEAR REDUCTION UNITS ( R DRIVE) with R Drive A Reducer Shown with non-jacketed relief valve with R Drive B Reducer with R Drive C Reducer Shown with non-jacketed relief valve Viking s jacketed bracket pump Series 5 and 5 are available with helical gear reducers that have been specifically developed for efficient operation with Viking heavy-duty pumps. These rugged, compact, exceptionally quiet gear reducers come in three sizes: the small A size, medium B size and large C size. The A size reducer, available with four gear ratios (.,.76,., and.7 to ), is ideally suited for use with the H and HL size pumps. This reducer is bracket mounted and requires couplings on both the input and output shafts. With the A size reducer and 00 or 800 RPM motors, the H and HL size pumps can be used to cover a capacity range from to GPM. The medium size B helical gear reducer is available with eight gear ratios from.87: to 7.65:. This size normally is used with pump sizes K through LS. Like the A reducer, the B reducer is bracket mounted and requires couplings on both the input and the output shafts. With the B reducer, K through LS pumps driven by 00 or 800 RPM motors can be used to cover a capacity range from to 0 GPM. The large C size reducer also is available with seven gear ratios from.: to 7.95:. It is normally used with the L through M size pumps. Like the A and B reducers, the C reducer is bracket mounted and requires flexible couplings both for the input and output shafts. With the C reducer, L through M size pumps, driven by 00 or 800 RPM motors, can cover a capacity range from 0 to 0 GPM. Dimensions for R Drive Units See Pages.0 and.. Performance Data for R Drive Units See Pages.5 through..

4 Section Page. Issue C VIKING HEAVY DUTY PUMPS VIKING HELICAL GEAR REDUCER UNITS ( R DRIVE) SPECIFICATIONS R DRIVE UNITS Packed Model Number Port Size Nominal Pump Rating Mech. Seal Inches GPM (m³/hr) RPM Motor HP Required At Rated Speed Pumping 00 SSU Liquid 50 PSI ( BAR) Hydro- Static Steel Fitted Construction Above This Viscosity Discharge When Handling 00 SSU Liquid At Nominal Rated Speeds 00 PSI (7 BAR) PSIG (BAR) SSU (cst) PSIG Temperature / of Fluids in Jackets Steam (Sat.) PSIG (BAR) Heat Transfer Oil PSIG (BAR) A Reducer Approximate Shipping Weight (Less Power) Pounds (KG) H5R H5R ½ 5 () 800 ½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 9 (59) HL5R HL5R ½ 0 (7) (8) 7,500 (,650) (85) 50 (0) 50 () 50 (0) 5 (6) K5R K5R 60 () 60 7½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0).... (55).... KK5R KK5R 80 (8) ½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) (58) 565 (57) L5R L5R 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) (8) 60 (77) LQ5R LQ5R ½ 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) (95) 60 (9) LL5R LL5R 0 () 50 7½ 5 00 (8),500 (550) (85) 50 (0) 50 () 50 (0) (09) 670 (0) LS5R LS5R 00 (5) (8) 75,000 (6,500) (85) 50 (0) 50 () 50 (0) () 70 (7) Q5R Q5R 00 (68) (8) 7,500 (,650) (85) 50 (0) 50 () 50 (0) (7) M5R M5R 0 (95) (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) (56) B Reducer C Reducer PTFE fitted mechanical seal used in Series 5 pumps. For mechanical seal pumps on applications with viscosities greater than 5,000 SSU (5,500 cst) anytime during operating cycle, check with factory. For maximum recommended discharge pressures when handling other vis cosities and/or at other speeds, see performance curves. If suction pressure exceeds 50 PSIG ( BAR), consult factory. Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. Metric conversions are based on US measurements and rounded to the nearest whole number. OUTSTING FEATURES. Mounts NEMA standard motors, 00 or 800 RPM. (5 HP, 800 RPM maximum with A reducer; 5 HP, 800 RPM maximum with B reducer, and 0 HP, 800 RPM maximum with C reducer.). Complete reducers within a size may be interchanged on a Viking pump unit to obtain desired pump speeds and capacities. Thus the four gear ratios within the A size reducer may be interchanged within the size by selecting the proper pinion and gear of a common ratio. Similarly, all eight B reducers are interchangeble on each respective series of B reducer units. All seven C reducers are interchangeable on each respective series of C reducer units.. Quiet operation. High hardness helical gears run in a bath of oil.. Compact. Narrow and low to fit in small space and low overhead Pump, motor or reducer can be removed without disturbing the other two components. Units with A, B and C reducers have standard flexible coupling with guard between power and reducer as well as between reducer and pump. Oil and weather tight for outdoor service. Ball bearings throughout. Reducers easily adjustable to different motor center heights. Self-supported. Not hung on pump or motor shafts. No radial load on pump or motor shafts. A reducers have ¾ dia., ³ ₁₆ key input and output shafts; B reducers have dia., ¼ key input shaft and ⅛ dia., ¼ key output shaft; C reducers have ⅜ dia., ⁵ ₁₆ key input and output shafts.

5 VIKING HEAVY DUTY PUMPS Section Page.5 Issue B VIKING HELICAL GEAR REDUCTION UNITS ( R DRIVE) HELICAL REDUCER HORSEPOWER TABLE A SIZE HIGH SPEED SHAFT INPUT RPM GEAR REDUCER RATIOS A SIZE LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM...6. MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP For input speeds higher than 750 RPM, consult the factory. Horsepower ratings based on 8-0 hours operation per day, electric motor drive. See Catalog Section 60 for specific reducer sizing information. HELICAL REDUCER HORSEPOWER TABLE B SIZE HIGH SPEED SHAFT INPUT RPM GEAR REDUCER RATIOS B SIZE LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP For input speeds higher than 750 RPM, consult the factory. Horsepower ratings based on 8-0 hours operation per day, electric motor drive. See Catalog Section 60 for specific reducer sizing information. HELICAL REDUCER HORSEPOWER TABLE C SIZE HIGH SPEED SHAFT INPUT RPM GEAR REDUCER RATIOS C SIZE.:.80:.:.: 5.08: 6.: 7.95: LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP LOW SPEED SHAFT RPM MAXIMUM REDUCER HP For input speeds higher than 750 RPM, consult the factory. Horsepower ratings based on 8-0 hours operation per day, electric motor drive. See Catalog Section 60 for specific reducer sizing information.

6 Section Page.6 Issue C VIKING HEAVY DUTY PUMPS GEAR REDUCER UNITS ( P DRIVE) with P Drive K through L Sizes with P Drive LQ through M Sizes Viking s Heavy-Duty Series 5 and 5 packed and mechanical seal pumps in sizes from K through M (60 to 0 GPM) are available in the P drive arrangement. These Heavy-Duty units are mounted on formed steel bases ( K through LS sizes) and structural or formed steel bases ( Q and M sizes) as illustrated above. All mount separate heavy-duty reducers with flexible couplings between pump, reducer and motor. Coupling guards as illustrated are standard construction. See below for specifications and motor horsepower range. Dimensions for P Drive Units Consult Factory. Performance Data for P Drive Units See Pages.5 through.. SPECIFICATIONS P DRIVE UNITS Packed Model Number Port Size 5 Nominal Pump Rating Mech. Seal Inches GPM (m³/hr) RPM Motor HP Required At Rated Speed Pumping 00 SSU Liquid 50 PSI ( BAR) Hydrostatic Steel Fitted Construction Above This Viscosity Discharge When Handling 00 SSU Liquid At Nominal Rated Speeds 00 PSI (7 BAR) PSIG (BAR) SSU (cst) (PSIG) Steam (Sat.) Temperature / of Fluids In Jackets PSIG (BAR) Heat Transfer Oil Approximate Shipping Weight (Less Power) PSIG (BAR) Pounds (KG) K5P K5P 60 () 60 7½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 6 (65) KK5P KK5P 80 (8) ½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 68 (67) L5P L5P 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) (88) LQ5P LQ5P ½ 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) (0) LL5P LL5P 0 () 50 7½ 5 00 (8),500 (550) (85) 50 (0) 50 () 50 (0) 7 (5) LS5P LS5P 00 (5) (8) 75,000 (6,500) (85) 50 (0) 50 () 50 (0) 8 (9) Q5P Q5P 00 (65) (8) 7,500 (,650) (85) 50 (0) 50 () 50 (0) 80 (77) M5P M5P 0 (95) (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 966 (9) Note: recommended temperature for cataloged pump is 50 F. For higher temperatures consult factory. PTFE fitted mechanical seal used in Series 5 pumps. For mechanical seal pumps on applications with viscosities greater than 5,000 SSU (5,500 cst) anytime during operating cycle, check with factory. For maximum recommended discharge pressures when handling other viscosities and/or at other speeds, see performance curves. If suction pressure exceeds 50 PSIG ( BAR), consult factory. Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. 5 Nominal rating based on handling thin liquids. Metric conversions are based on US measurements and rounded to the nearest whole number.

7 VIKING HEAVY DUTY PUMPS Section Page.7 Issue C DIRECT DRIVE UNITS ( D DRIVE) with D Drive K through M Sizes K size shown with non-jacketed head with D Drive H and HL Sizes Shown with non-jacketed head The Direct Drive D mounting is specifically designed for compactness and quietness of operation. In this type assembly the pump is mounted on one end of a rectangular formed steel base and connected to a gearhead motor by means of a flexible coupling with guard. H and HL sizes can be directly connected to 800 RPM motors, as well as gearhead motors. Dimensions for D Drive Units See Pages. and.. Performance Data for D Drive Units See Pages.5 through.. SPECIFICATIONS d DRIVE UNITS Packed Model Number Port Size 5 Nominal Pump Rating Mech. Seal Inches GPM (m³/hr) RPM Motor HP Required At Rated Speed Pumping 00 SSU Liquid 50 PSI ( BAR) Hydrostatic Steel Fitted Construction Above This Viscosity Discharge When Handling 00 SSU Liquid At Nominal Rated Speeds 00 PSI (7 BAR) PSIG (BAR) SSU (cst) (PSIG) Steam (Sat.) Temperature / of Fluids In Jackets PSIG (BAR) Heat Transfer Oil PSIG (BAR) Approximate Shipping Weight (Less Power) Pounds (KG) H5D H5D ½ 5 () 800 ½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 09 (9) HL5D HL5D ½ 0 (7) (8) 7,500 (,650) (85) 50 (0) 50 () 50 (0) 5 (5) K5D K5D 60 () 60 7½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 5 () KK5D KK5D 80 (8) ½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 75 (5) L5D L5D 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 0 (5) LQ5D LQ5D ½ 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 70 (68) LL5D LL5D 0 () 50 7½ 5 00 (8),500 (550) (85) 50 (0) 50 () 50 (0) 5 (9) LS5D LS5D 00 (5) (8) 75,000 (6,500) (85) 50 (0) 50 () 50 (0) 5 (97) Q5D Q5D 00 (68) (8) 7,500 (,650) (85) 50 (0) 50 () 50 (0) 860 (90) M5D M5D 0 (95) (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 00 (6) Note: recommended temperature for cataloged pump is 50 F. For higher temperatures consult factory. PTFE fitted mechanical seal used in Series 5 pumps. For mechanical seal pumps on applications with viscosities greater than 5,000 SSU (5,500 cst) anytime during operating cycle, check with factory. For maximum recommended discharge pressures when handling other viscosities and/or at other speeds, see performance curves. If suction pressure exceeds 50 PSIG ( BAR), consult factory. Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. 5 Nominal rating based on handling thin liquids. Metric conversions are based on US measurements and rounded to the nearest whole number.

8 Section Page.8 Issue C VIKING HEAVY DUTY PUMPS V-BELT DRIVE UNITS ( V DRIVE) with V Drive H through M Size Pumps Viking s V-belt driven line of Heavy-Duty Series 5 and 5 pumps are all mounted on formed welded steel bases. Pumps mount on pads to accept totally enclosed V-belt drive. All units in this series feature standard pump shaft extension with totally guarded V-driven pulley mounted on end of heavy-duty pump shaft. Pumps furnished with jacketed head as standard. Dimensions for V Drive Units See Page.. Performance Data for V Drive Units See Pages.5 through.. SPECIFICATIONS v DRIVE UNITS Packed Model Number Port Size 5 Nominal Pump Rating Mech. Seal Inches GPM (m³/hr) RPM Motor HP Required At Rated Speed Pumping 00 SSU Liquid 50 PSI ( BAR) Hydrostatic Steel Fitted Construction Above This Viscosity Discharge When Handling 00 SSU Liquid At Nominal Rated Speeds 00 PSI (7 BAR) PSIG (BAR) SSU (cst) (PSIG) Steam (Sat.) Temperature / of Fluids In Jackets PSIG (BAR) Heat Transfer Oil Approximate Shipping Weight (Less Power) PSIG (BAR) Pounds (KG) H5V H5V ½ 5 () 800 ½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) (5) HL5V HL5V ½ 0 (7) (8) 7,500 (,650) (85) 50 (0) 50 () 50 (0) 9 (5) K5V K5V 60 () 60 7½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 70 () KK5V KK5V 80 (8) ½ 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 80 (7) L5V L5V 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 5 (8) LQ5V LQ5V ½ 5 () 60 7½ 5 00 (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 55 (6) LL5V LL5V 0 () 50 7½ 5 00 (8),500 (550) (85) 50 (0) 50 () 50 (0) 80 (7) LS5V LS5V 00 (5) (8) 75,000 (6,500) (85) 50 (0) 50 () 50 (0) 95 (79) Q5V Q5V 00 (68) (8) 7,500 (,650) (85) 50 (0) 50 () 50 (0) 06 (66) M5V M5V 0 (95) (8) 5,000 (5,500) (85) 50 (0) 50 () 50 (0) 78 (55) Note: recommended temperature for cataloged pump is 50 F. For higher temperatures consult factory. PTFE fitted mechanical seal used in Series 5 pumps. For mechanical seal pumps on applications with viscosities greater than 5,000 SSU (5,500 cst) anytime during operating cycle, check with factory. For maximum recommended discharge pressures when handling other viscosities and/or at other speeds, see performance curves. If suction pressure exceeds 50 PSIG ( BAR), consult factory. Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. 5 Nominal rating based on handling thin liquids. Metric conversions are based on US measurements and rounded to the nearest whole number.

9 VIKING HEAVY DUTY PUMPS Section Page.9 Issue B DIMENSIONS These dimensions are average and not for construction purposes. Certified prints on request. For specifications, see page.. DIMENSIONS UNMOUNTED PUMPS MODEL NO. PACKED SEAL A B C D E F G H J K N O P T U V W X Y C₁ L₁ M₁ N₁ R₁ S₁ AA BB CC H5 HL5 H5 ½ in x ¾ ½ HL5 mm x K5 KK5 K5 KK5 in x ¼ ¼ mm x L5 L5 in x ¼ mm x LQ5 LQ5 ½ in x ¼ mm x LL5 LL5 in x ¼ mm x LS5 LS5 in x ¼ mm x Q5 Q5 in x ½ ¼ mm x M5 M5 in x ½ ½ mm x Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard N.P.T. pipe. Model Q. R. Model M 5.5 R.

10 Section Page.0 Issue B VIKING HEAVY DUTY PUMPS DIMENSIONS These dimensions are average and not for construction purposes. Certified prints on request. For specifications, see pages. through.5. DIMENSIONS ( R DRIVE) H HL SIZE PUMPS A SIZE REDUCER UNITS A SIZE REDUCER MODEL NUMBER PACKED H5R HL5R SEAL H5R HL5R A B C E F G H J K L M N ½ in mm Base suitable for 56 through 8-T frame motors. (Base has closed ends.) For motor frame -T dimension G increases to.00. All other dimensions remain the same. (Base has open ends.) MODEL NUMBER B SIZE REDUCER For specifications, see pages. through.5. DIMENSIONS ( R DRIVE) K THROUGH LS SIZE PUMPS B SIZE REDUCER UNITS PACKED K5R KK5R SEAL K5R KK5R A B C E F G J K L M N L5R L5R LQ5R LQ5R ½ LL5R LL5R LS5R LS5R in mm in mm in mm in mm in mm Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. With motor frames 8-T and smaller, these units are assembled on a shorter base with the following dimension changes: (F = 6, G = 9, L =, N = 5⅝ ). Motor rails ⅞ high are required with 56, -T and 5-T frame motors. NOTE: Motor frame larger than 56-T requires larger base. Consult factory. Units available to accept 0 HP, 00 RPM maximum motor. NOTE: Motor rails high are required on L through LS size units with 8-T or ½ center height motors.

11 VIKING HEAVY DUTY PUMPS Section Page. Issue B DIMENSIONS These dimensions are average and not for construction purposes. Certified prints on request. For specifications, see pages. through.5. DIMENSIONS ( R DRIVE) KK THROUGH M SIZE PUMPS C SIZE REDUCER UNITS Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. MODEL NUMBER PACKED SEAL KK5R KK5R L5R L5R LQ5R LQ5R ½ LL5R LL5R LS5R LS5R Q5R M5R Q5R M5R A B C E F G J K L M N in mm in mm in mm in mm in mm in mm in mm For specifications, see page.7. DIMENSIONS ( D DRIVE) H HL SIZE PUMPS DIRECT CONNECTED UNITS For motor frames 56, -T and 5-T. (Base has open ends.) For motor frames 8, 8-T, 8 and 8-T. (Base has closed ends.) For motor frames through 5-T. (Base has closed ends.) MODEL NUMBER PACKED SEAL H5D H5D OR OR HL5D HL5D A B D E F K L M N S ½ ½ ½ in mm in mm in mm

12 Section Page. Issue B VIKING HEAVY DUTY PUMPS DIMENSIONS These dimensions are average and not for construction purposes. Certified prints on request. For specifications, see page.7. DIMENSIONS ( D DRIVE) K THROUGH M SIZE PUMPS DIRECT CONNECTED UNITS MODEL NUMBER PACKED K5D KK5D SEAL K5D KK5D A L5D L5D LQ5D LL5D LS5D Q5D M5D LQ5D LL5D LS5D Q5D M5D ½ B D E F J K L M N S in mm in mm in mm in mm in mm in mm in mm Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. Varies with gearmotor used. For specifications, see page.8. MODEL NUMBER PACKED H5V HL5V K5V KK5V L5V LQ5V LL5V LS5V Q5V M5V SEAL H5V HL5V K5V KK5V A B C E F G J K L M N ½ L5V LQ5V LL5V LS5V Q5V M5V ½ in mm in mm in mm in mm in mm in mm in mm in mm DIMENSIONS ( V DRIVE) H THROUGH M SIZE PUMPS V-BELT DRIVE UNITS Ports are suitable for use with 5# ANSI cast iron or 50# ANSI steel companion flanges or flanged fittings. All others tapped for standard pipe. Base dimensions correct for all motors. Base dimensions correct through frame 5-T motors and 9 OD sheaves. Larger motors and/or 5 OD sheaves require larger base.

PRODUCT OBSOLETED 1Q16

PRODUCT OBSOLETED 1Q16 VIKING HEAVY DUTY PUMPS FEATURES Section 6 Page 6. Issue C 9 SERIES 27 s Cutaway View (Packed Type) 60-200-280 GPM Sizes (36-45-64 m³/hr) Shown without over-pressure relief valve MECHANICAL SEAL (SERIES

More information

VIKING HEAVY DUTY ALLOY PUMPS SERIES 724 AND 4724

VIKING HEAVY DUTY ALLOY PUMPS SERIES 724 AND 4724 VIKING HEAVY DUTY ALLOY PUMPS Section 210 Page 210.1 FEATURES SERIES 4724 Cutaway View Mechanical, 1½, 3 and 5 GPM Sizes 1 Range 200 PSI (14 BAR) for (21 cst) and above (Small Pumps F, FH and G sizes)

More information

PRODUCT OBSOLETED 1Q16

PRODUCT OBSOLETED 1Q16 STANDARD CONSTRUCTION FEATURES Page 141.1 SERIES 15 Pumps Cutaway View (Packed Type) 8-15-0 GPM Sizes (--7 m³/hr) MECHANICAL SEAL (SERIES 415) G - HL, K - LL SIZES AK, AL, LS - M SIZES BRACKET 5 416 SHAFT

More information

VIKING GENERAL PURPOSE PUMPS SERIES 32 AND 432

VIKING GENERAL PURPOSE PUMPS SERIES 32 AND 432 Page 310.1 FEATURES SERIES 32 and 432 3 GPM (.7 m³/hr) Size Shown. or Mechanical seal type. Valve on casing. SERIES 432 5 GPM (1 m³/hr) Mechanical seal type. Shown with valve on head. C, F & FH Sizes J

More information

VIKING SPUR GEAR SINGLE PUMPS SERIES SG-04, SG-05, SG-07 AND SGN-05, SGN-07 STANDARD CONSTRUCTION FEATURES

VIKING SPUR GEAR SINGLE PUMPS SERIES SG-04, SG-05, SG-07 AND SGN-05, SGN-07 STANDARD CONSTRUCTION FEATURES VIKING SPUR GEAR SINGLE PUMPS FEATURES Section 34 Page 34. SERIES SG-04 and SG-05 Pumps Cutaway View.0 to.2 GPM Sizes (.0 to 2.5 m³/hr) SERIES SG-07 Pump Cutaway View 2.8 to 32.0 GPM Sizes (. to 7 m³/hr)

More information

VISCOSITY RANGE GPM m 3 h PSI Bar F C SSU cst

VISCOSITY RANGE GPM m 3 h PSI Bar F C SSU cst UNIVERSL PRODUCT LINE: SERIES 724, 4724 Section 1706 Page 1706.1 Issue B TBLE OF CONTENTS Features & Benefits...2 Cutaway View & Pump Features...2 Model Number Key...3 Standard Materials of Construction...3

More information

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE SERIES 4223, 4323 (API 682 Seal) Section 304 Page 304. TABLE OF CONTENTS Features & Benefits...2 Revolvable Pump Casings...2 Materials of Construction...2 Cutaway View & Pump Features...3 Key...4 Specifications...4

More information

VIKING JACKETED ASPHALT PUMPS

VIKING JACKETED ASPHALT PUMPS VIKING ED ASPHALT PUMPS SERIES 34 AND 434 Section 430 Page 430.1 Issue G FEATURES 1 Pressure 1 Temperature 1 Viscosity 1 Flow To 100 PSI (6.9 Bar) -60 F. to +450 F. (-51 C. to +232 C.) 31 SSU to 250,000

More information

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE Page 1602.1 TABLE OF CONTENTS Features & Benefits...2 Porting & Sealing...2 Jacketing...2 Revolvable Pump Casings...2 Cutaway View & Pump Features...3 Model Number Key...4 Standard Materials of Construction...4

More information

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE SERIES 223A, 4223A, 323A, 4323A Page 1302.1 Issue B TABLE OF CONTENTS Features & Benefits...2 Jacketing...2 Relief Valve Configurations...3 Porting & Sealing...3 Revolvable Pump Casings...3 Cutaway View

More information

Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Stainless Steel.

Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Stainless Steel. Page 630.1 Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options Standard Pump (shown: KK124A) Operating Range 1 : Cast Iron Series: 124A/AE, 4124A/AE, 324A, 4324A, 224A/AE, 4224A/AE

More information

VIKING UNIVERSAL SEAL PUMPS. Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options. Operating Range1: Nominal Flow Rates:

VIKING UNIVERSAL SEAL PUMPS. Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options. Operating Range1: Nominal Flow Rates: VIKING UNIVERSAL SEAL PUMPS Section 630 Page 630.1 Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options Operating Range1: Cast Iron Series 124A/AE, 4124A/AE, 4124B, 324A, 4324A, 224A/AE,

More information

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A Page 1601.1 TABLE OF CONTENTS Features & Benefits...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features...4 Special Materials & Options

More information

UNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE:

UNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE: Page 1701.1 TABLE OF CONTENTS Features & Benefits...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features...4 Special Materials & Options

More information

UNIVERSAL PRODUCT LINE: STAINLESS STEEL JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: STAINLESS STEEL JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE UNIVERSAL PRODUCT LINE: SERIES 227A, 4227A, 327A, 4327A Section 1702 Page 1702.1 Issue B TABLE OF CONTENTS Features & Benefits...2 Jacketing...2 Relief Valve Configurations...3 Porting & Sealing...3 Revolvable

More information

VIKING UNIVERSAL SEAL PUMPS. Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options. Operating Range: Nominal Flow Rates:

VIKING UNIVERSAL SEAL PUMPS. Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options. Operating Range: Nominal Flow Rates: VIKING UNIVERSAL SEAL PUMPS Section 630 Page 630. Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Options Standard Pump (shown: KK123A) Jacketed Pump (shown: KK4223A) Nominal Flow Rates: Pump

More information

UNIVERSAL PRODUCT LINE: CAST IRON NON-JACKETED PUMPS SERIES DESCRIPTION TABLE OF CONTENTS RELATED PRODUCTS OPERATING RANGE:

UNIVERSAL PRODUCT LINE: CAST IRON NON-JACKETED PUMPS SERIES DESCRIPTION TABLE OF CONTENTS RELATED PRODUCTS OPERATING RANGE: Page 1401.1 TABLE OF CONTENTS Features & Benefits...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features (124A/AE, 4124A/AE, 324A, 4324A)...4

More information

L Q LIQUID-SPECIFIC PRODUCT LINE: CAST IRON ASPHALT PUMPS SERIES DESCRIPTION (34 & 32E) OPERATING RANGE: MODEL NUMBER KEY:

L Q LIQUID-SPECIFIC PRODUCT LINE: CAST IRON ASPHALT PUMPS SERIES DESCRIPTION (34 & 32E) OPERATING RANGE: MODEL NUMBER KEY: LIQUID-SPECIFIC PRODUCT LINE: SERIES 4A, 4AE, 44A, 44AE, 34A, 434A, 14E, 34E, 34, 3E Section 430 Page 430.1 Issue S SERIES DESCRIPTION (34 & 3E) Viking 34 Series Asphalt Pumps are designed to handle asphalts,

More information

SPUR GEAR PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1451 Page 1451.

SPUR GEAR PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1451 Page 1451. Page 1451.1 TABLE OF CONTENTS Features & Benefits...2 Typical Applications...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features...4 Component

More information

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442. Page 1442.1 TABLE OF CONTENTS Features & Benefits...2 Standard Materials of Construction...2 Specifications...2 Model Number Key...3 Cutaway View & Pump Features...3 Dimensions C, F, FH Sizes...4 Dimensions

More information

VIKING HEAVY DUTY PUMPS SERIES 4197 STAINLESS STEEL FEATURES

VIKING HEAVY DUTY PUMPS SERIES 4197 STAINLESS STEEL FEATURES VIKING HEAVY DUTY PUMPS FEATURES Section 64 Page 64. s Cutaway View 0--0 GPM Sizes (2-4.5-7 m³/hr) s Cutaway View 5-50-75 GPM Sizes (8--7 m³/hr) Pressure Range Temperature Range Viscosity Range 0 PSI (4

More information

VIKING HEAVY DUTY PUMPS SERIES 4193 AND 493 STEEL EXTERNALS FEATURES

VIKING HEAVY DUTY PUMPS SERIES 4193 AND 493 STEEL EXTERNALS FEATURES VIKING HEAVY DUTY PUMPS SERIES 49 AND 49 FEATURES Section 54 Page 54. Issue C Pressure Range 2 Temperature Range Viscosity Range 250 PSI ( BAR) for 00 SSU ( cst) and above 50 PSI (0 BAR) for 8 to 00 SSU

More information

GEAR PUMPS TOUGH INTERNAL GEAR SIMPLE SIMPLE EXTERNAL GEAR COST EFFECTIVE COST EFFECTIVE

GEAR PUMPS TOUGH INTERNAL GEAR SIMPLE SIMPLE EXTERNAL GEAR COST EFFECTIVE COST EFFECTIVE TOUGH INTERNAL GEAR GEAR PUMPS SIMPLE SIMPLE EXTERNAL GEAR COST EFFECTIVE COST EFFECTIVE NOMAD GEAR PUMPS California-based JDA GLOBAL LLC, the world s largest provider of after-market diaphragm pump products,

More information

VIKING HEAVY DUTY PUMPS

VIKING HEAVY DUTY PUMPS SERIES 495 STANDARD CONSTRUCTION Section 44 Page 44. Issue D FEATURES Range Temperature Range Viscosity Range 250 PSI (7 BAR) for 00 SSU ( cst) and above 50 PSI (0 BAR) for 8 to 00 SSU ( cst to cst) 00

More information

VIKING SG SERIES SINGLE PUMPS (WITH SHAFT SEAL)

VIKING SG SERIES SINGLE PUMPS (WITH SHAFT SEAL) SERIES SG-04, -05, -07, -10, -14 () Page 341.1.1 OPERATING RANGE: SERIES SG-04/-05 PUMP SG Pumps (, Lip or Mechanical Sealed) Displacements No. 29 Flow Range Pressure Range Temperature Range Viscosity

More information

POMPE À ENGRENAGES GEAR PUMP ASYBCO

POMPE À ENGRENAGES GEAR PUMP ASYBCO POMPE À ENGRENAGES GEAR PUMP ASYBCO GEAR PUMP Series 5 Canadian General Purpose Designed and engineered to serve petroleum, chemical, process and manufacturing industries. GPM (289 L/m) PSI (690 kpa) /2

More information

TOUGH SIMPLE GEAR PUMPS COST EFFECTIVE TOUGH SIMPLE COST EFFECTIVE. Tel: / Int'l: Fax: / Int'l:

TOUGH SIMPLE GEAR PUMPS COST EFFECTIVE TOUGH SIMPLE COST EFFECTIVE. Tel: / Int'l: Fax: / Int'l: GEAR PUMPS TOUGH TOUGH SIMPLE SIMPLE COST EFFECTIVE COST EFFECTIVE NOMAD GEAR PUMPS California-based JDA GLOBAL LLC, the world s largest provider of after-market diaphragm pump products, in conjunction

More information

GEAR PUMPS TOUGH TOUGH SIMPLE SIMPLE COST EFFECTIVE COST EFFECTIVE

GEAR PUMPS TOUGH TOUGH SIMPLE SIMPLE COST EFFECTIVE COST EFFECTIVE GEAR PUMPS TOUGH TOUGH SIMPLE SIMPLE COST EFFECTIVE COST EFFECTIVE NOMAD GEAR PUMPS California-based JDA GLOBAL LLC, the world s largest provider of after-market diaphragm pump products, in conjunction

More information

Viking SL Industrial Lobe Pump Series

Viking SL Industrial Lobe Pump Series Section 288 Page 288. Viking SL Industrial Lobe Pump Series This product brings gentle low shear pumping action with in-line cleaning capabilities to the industrial markets. Rugged enough for corrosive

More information

Product Range IDEX CORPORATION

Product Range IDEX CORPORATION Product Range IDEX CORPORATION Viking Pump provides an unmatched combination of application expertise and positive displacement pumping products to meet your pumping needs. We specialize in the design,

More information

VIKING MOTOR SPEED INTERNAL GEAR PUMPS

VIKING MOTOR SPEED INTERNAL GEAR PUMPS VIKING MOTOR SPEED Series Description Vikg s Motor Speed series ternal gear pumps represent a technological advance the science of flow. Through new techniques of feedg the rotor and idler, Vikg has achieved

More information

MOTOR SPEED PRODUCT LINE: CAST IRON MAG DRIVE PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

MOTOR SPEED PRODUCT LINE: CAST IRON MAG DRIVE PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE MOTOR SPEED PRODUCT LINE: SERIES 895 Section 1443 Page 1443.1 Issue B TBLE OF CONTENTS Features & Benefits...2 Standard Materials of Construction...2 Key...3 Cutaway View & Pump Features...3 Specifications...4

More information

Nominal Flow Pressure Range Temp. Range Viscosity Range

Nominal Flow Pressure Range Temp. Range Viscosity Range VIKING UNIVERSL XPD 676 PUMPS - FULL COMPLINCE with PI 676 STNDRDS SERIES 4223X & 4323X Section 633 Page 633.1 Heavy-Duty, Foot-Mounted Internal Gear Pumps Offering Full Compliance with PI 676 Design Standards

More information

VIKING. Series LVP STAINLESS STEEL VANE PUMP. VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA 2016 PRODUCT DESCRIPTION SERIES OPERATING RANGE

VIKING. Series LVP STAINLESS STEEL VANE PUMP. VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA 2016 PRODUCT DESCRIPTION SERIES OPERATING RANGE Page 445.1 PRODUCT DESCRIPTION Rotary vane pumps are used for liquid transfer in applications ranging from chemicals to LP gas. Vanes extend from slots on the rotor, sweeping liquid through a cam-shaped

More information

VIKING. Series LVP. VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA Section 445 Page Issue C

VIKING. Series LVP. VIKING PUMP A Unit of IDEX Corporation Cedar Falls, IA Section 445 Page Issue C VIKING Section 445 Page 445.1 Issue C PRODUCT DESCRIPTION Rotary vane pumps are used for liquid transfer in applications ranging from chemicals to LP gas. Vanes extend from slots on the rotor, sweeping

More information

LIQUID-SPECIFIC PRODUCT LINE: STAINLESS STEEL VANE PUMPS PRODUCT DESCRIPTION SERIES OPERATING RANGE 1 NOMINAL FLOW RATES 2

LIQUID-SPECIFIC PRODUCT LINE: STAINLESS STEEL VANE PUMPS PRODUCT DESCRIPTION SERIES OPERATING RANGE 1 NOMINAL FLOW RATES 2 Page 445.1 PRODUCT DESCRIPTION SERIES OPERATING RANGE 1 Rotary vane pumps are used for liquid transfer in applications ranging from chemicals to LP gas. Vanes extend from slots on the rotor, sweeping liquid

More information

Basic Hydraulic Features. Basic Mechanical Features

Basic Hydraulic Features. Basic Mechanical Features APRIL 2006 1.0 Overview The ETA is designed for flow rates that fall beyond the range of most end suction pumps. Performance extends to 9,500 GPM, 440 feet of head, and 88% efficiency. This range is covered

More information

V Rev US

V Rev US V - 0805 Rev. 05 - US APPLICATIONS INDUSTRIES V series internal gear rotary pumps are suitable for pumping liquids of any viscosity. Solids cannot be handled, but the pumps can cope with abrasive particles.

More information

LACT PERFORMANCE PRODUCTS

LACT PERFORMANCE PRODUCTS LACT PRODUCTS DURABLE & RELIABLE SOLUTIONS BOLTS PLUG LID Low Pressure Drop Inclined basket design for low pressure drop and high system efficiency O-RING Easy to Clean Top basket removal eliminates the

More information

BSM ROTARY GEAR PUMPS

BSM ROTARY GEAR PUMPS -SERIES FLG. MTD. PUMP PUMP FOOT The BSM -Series pumps are designed to provide quiet and efficient service at standard motor speeds, moderately high pressures. Typical applications are supplying hydraulic

More information

CLARK SOLUTIONS S Series Rotary Gear Pump Pressure to 200 PSI, Flow to 32 GPM, Drive Speed to 1800 RPM

CLARK SOLUTIONS S Series Rotary Gear Pump Pressure to 200 PSI, Flow to 32 GPM, Drive Speed to 1800 RPM CLARK SOLUTIONS S Series Rotary Gear Pump Pressure to 200 PSI, Flow to 32 GPM, Drive Speed to 1800 RPM DESCRIPTION Series S pumps are general purpose positive displacement gear pumps and are a good choice

More information

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1441 Page 1441.

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1441 Page 1441. MOTOR SPD PRODCT LIN: SRIS 495, 495 Section 44 Page 44. Issue TL OF CONTNTS Features & enefits...2 Standard Materials of Construction...2 Cutaway View & Pump Features...3 Key...4 Specifications...4 Mounting

More information

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS Page 350.1 Series Description Viking s HG series positive displacement pumps are designed to provide low noise transfer and processing of clean, lubricating liquids for applications such as lube oils,

More information

VIKING SG SERIES SEALLESS MAG DRIVE PUMPS

VIKING SG SERIES SEALLESS MAG DRIVE PUMPS SERIES SG-04, -05, -07, -0, -4 (Cast Iron) Section 34.3 Page 34.3. OPERATING RANGE: SG Pumps (Cast Iron Mag Drive) and SGN (Ductile Iron Mag Drive) Displacements No. 23 SG and 7 SGN 0.06 to 90 (SG) and

More information

High Temperature Chemical Process Inline Pumps

High Temperature Chemical Process Inline Pumps Bulletin C-1.2.21. Dean Pump Division High Temperature Chemical Process Inline Pumps Series DL Series DL High Temperature Chemical Process Inline Pumps Capacities to 6 GPM (182 m 3 /hr) Heads to feet (167

More information

PIPELINE INJECTION PRODUCTS

PIPELINE INJECTION PRODUCTS PIPELINE INJECTION PRODUCTS DURABLE & RELIABLE SOLUTIONS PIPELINE INJECTION PUMP GP-10 & GP-1 SERIES Flows up to: 210 GPM / BPH / 7,20 BPD (nominal flow) BUSHINGS BACK PULL OUT SEAL HEAD DRIVER SHAFT DRIVEN

More information

High Temperature Air-Cooled Hot Oil Pumps

High Temperature Air-Cooled Hot Oil Pumps Bulletin C 1.4.42 Dean Pump Division High Temperature Air-Cooled Hot Oil Pumps No Water Cooling Required RA3 RA2 DEAN PUMP SERIES RA FAN COOLED HIGH TEMPERATURE HOT OIL PUMPS No Liquid Cooling Required

More information

Positive Displacement Rotary Vane Pumps For Fluid Processing and Transfer Applications

Positive Displacement Rotary Vane Pumps For Fluid Processing and Transfer Applications Full Line Bulletin One Section: 100 Effective: March 2014 Replaces: February 2012 Positive Displacement Rotary s For Fluid Processing and Transfer Applications Blackmer Fluid Processing and Transfer s

More information

A Series General Purpose Pumps General Purpose Pumps for Pressure Lubrication, Hydraulic Service, Fuel Supply and General Transfer

A Series General Purpose Pumps General Purpose Pumps for Pressure Lubrication, Hydraulic Service, Fuel Supply and General Transfer THE LEADING FORCE behind liquids since 1857 A Series General Purpose Pumps General Purpose Pumps for Pressure Lubrication, Hydraulic Service, Fuel Supply and General Transfer The Roper Pump Family of Gear

More information

VISCOSITY RANGE GPM m 3 h PSI Bar F C SSU cst

VISCOSITY RANGE GPM m 3 h PSI Bar F C SSU cst SERIES 493, 493 Section 34 Page 34. TBLE OF CONTENTS Features & Benefits...2 Specifications...2 Standard Materials of Construction...2 Key...3 Cutaway View & Pump Features...3 Mountg Options...4 Dimensions

More information

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs Bulletin BX-1H Bell & Gossett Series HSC-S Pumps Technical Bulletin Part of the Bell & Gossett Equipment Selection Programs TABLE OF CONTENTS Useful Pump Formulas...............................................

More information

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS 3312 Model pumping 3314 Model 3311 Model AURORA 3310 Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS WWW.AURORAPUMP.COM AURORA 3310 Series Horizontal and Vertical Close-Coupled Pumps Capacities to 3800

More information

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C)

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C) 3800 Series Single Stage End Suction Pumps Capacities to 200 G.P.M. (95 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (19 C) MODEL 380 Aurora 3800 Pump Setting New Standards of Efficiency

More information

BSM ROTARY GEAR PUMPS

BSM ROTARY GEAR PUMPS FT. MTD. PUMP B-Series pumps are a good choice for a variety of recirculating, mixing, and transfer applications. Typical pumped liquids include solvents, resins, and petroleum products. These pumps are

More information

OPERATION MANUAL INTERNAL GEAR PUMP. Models: NG-H, NG-HL, NG-K, NG-KK, NG-L, NG-LQ, NG-LL, NG-LS, NG-Q, NG-QS. Tel: Fax:

OPERATION MANUAL INTERNAL GEAR PUMP. Models: NG-H, NG-HL, NG-K, NG-KK, NG-L, NG-LQ, NG-LL, NG-LS, NG-Q, NG-QS. Tel: Fax: OPERATION MANUAL INTERNAL GEAR PUMP Models: NG-H, NG-HL, NG-K, NG-KK, NG-L, NG-LQ, NG-LL, NG-LS, NG-Q, NG-QS. 1 Contents Pump Designation System Maintenance Thrust bearing adjustment Pressure Relief Valve

More information

EN. 850 Filtrate Pumps. Technical Specification Pages

EN. 850 Filtrate Pumps. Technical Specification Pages 850 17.01.EN 850 Filtrate Pumps Technical Specification Pages 850 Series Filtrate Pump 850 17.01.EN This page left intentionally blank. 1.0 Overview. The 850 is Carver s filtrate pump line designed for

More information

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE Index Sheet ITEM S Bulletin Product Numbering System... 1 Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC... 2 Pump Assembly, Types AC & AE... 3-4 Dimensions, Types AC & AE... 5-8 Selection Curves,

More information

Series HSC-S Pumps Technical Brochure

Series HSC-S Pumps Technical Brochure Series HSCS Pumps Technical Brochure BX512L Table of Contents Useful Pump Formulas 2 60 Cycle Performance Curves Series HSCS 3 50 Cycle Performance Curves Series HSCS 4 Series HSCS Materials of Construction

More information

CLOSED COUPLED CENTRIFUGAL PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS SECTION B PAGE 0 ISSUED /0 REPLACES /0 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: G6--/ thru G9-F 0 Third Street Piqua, Ohio 6-060 CLOSED COUPLED CENTRIFUGAL PUMPS 00RPM

More information

BSM ROTARY GEAR PUMPS

BSM ROTARY GEAR PUMPS FT. MTD. PUMP The Heavy Duty S-Series pumps are designed to handle a wide variety of liquids and are particularly suitable for bulk transfer applications where long life and dependable service is required.

More information

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS TECHNICAL Brochure BAC8 Series A-C 8 SPLIT CASE PUMPS TABLE OF CONTENTS Useful Pump Formulas 2 Performance Curves 3-5 Materials of Construction (Standard) 6 Materials of Construction (Optional) 7 Pump

More information

CLOSED COUPLED CENTRIFUGAL PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS SECTION B PAGE 0 ISSUED /0 REPLACES /0 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: G6--/ thru G9-F 0 Third Street Piqua, Ohio 6-060 CLOSED COUPLED CENTRIFUGAL PUMPS 00RPM

More information

PRODUCT OBSOLETED 1Q16

PRODUCT OBSOLETED 1Q16 TECHNICAL SERVICE MANUAL HEAVY DUTY STEEL EXTERNAL MOUNTED PUMPS SERIES 123 AND 4123 SIZES H-LL SECTION TSM 151.1 PAGE 1 OF 13 ISSUE C CONTENTS Introduction 1 Special Information 2 Maintenance 3 Packed

More information

PRODUCT OBSOLETED 4Q16

PRODUCT OBSOLETED 4Q16 Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL SECTION TSM 141.1 HEAVY-DUTY BRACKET MOUNTED PUMPS PAGE 1 of 16 SERIES

More information

M50 L50 Series Multistage Regenerative Turbine Pumps

M50 L50 Series Multistage Regenerative Turbine Pumps Page M- MTH PUMPS M L Series Multistage Regenerative Turbine Pumps Capacities to 4 GPM Heads to Feet Single or Multi-stage Units (up to stages) Vertical Close Coupled Horizontal Close Coupled Horizontal

More information

Coro-Flo Sales Catalog

Coro-Flo Sales Catalog LPGCFP100C LPG Pumps Coro-Flo Sales Catalog FF-Model DL-Model DLF-Model C-Model Table of Contents General Information What is a Coro-Flo Pump...3 History of the Coro-Flo Pump... 4 Markets Served... 4 Model

More information

8L SERIES THREE SCREW PUMPS

8L SERIES THREE SCREW PUMPS TM 8L SERIES THREE SCREW PUMPS The reliable pump people ROTARY SCREW PUMPS Performance Shown at 1500 PSID (103 BAR), 200 SSU (43 CST) 60 HZ: 870 1150 1750 50 HZ: 960 1450 1200 1100 630M 40 250 1000 900

More information

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: G-H, G-HL, G-K, G-KK, G-L, G-LQ, G-LL, GLS, G-Q, G-QS 1 Contents Maintenance Thrust bearing adjustment

More information

Viking Helical Gear Reducers

Viking Helical Gear Reducers Page 610.1 Issue J Gear Ratio Range: (varies by reducer size) 1.87:1 to 7.95:1 Output Speeds (with 1750 rpm input) Reducer Horsepower Range: 950 to 220 rpm 1.4 HP (.1 kw) to 49.8 HP (37.2 kw) THREE SIZES

More information

VSC /VSCS Pumps Technical Brochure

VSC /VSCS Pumps Technical Brochure VSC /VSCS Pumps Technical Brochure BX-4C VSC/VSCS Construction Materials STANDARD SEAL CONFIGURATION PART NAME STANDARD CONSTRUCTION ASTM NO. Casing Cast iron A159 Class G0 Volute cover plate (Outboard)

More information

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps 855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps Technical Specification Pages This page left intentionally blank. 1.0 Overview. The 855 Series is Carver s offering specifically designed to

More information

LUBE OIL PUMPS. Critical Lubrication Service for: Bearings Seals Gearboxes. on... Gas & Steam Turbines Compressors Engines Starting Packages

LUBE OIL PUMPS. Critical Lubrication Service for: Bearings Seals Gearboxes. on... Gas & Steam Turbines Compressors Engines Starting Packages LUBE OIL PUMPS Critical Lubrication Service for: Bearings Seals Gearboxes on... Gas & Steam Turbines Compressors Engines Starting Packages LEADING SUPPLIER OF LUBE OIL PUMPS TO THE POWER GENERATION INDUSTRY

More information

BSM ROTARY GEAR PUMPS

BSM ROTARY GEAR PUMPS FT. MTD. PUMP BSM bronze pumps are ideal for use where corrosion resistant materials are required such as providing circulation on water-jacketed engines, pumping saline solutions as well as a variety

More information

High Temperature Air-Cooled Hot Oil Pumps

High Temperature Air-Cooled Hot Oil Pumps Bulletin C 1.4.42 Dean Pump Division High Temperature Air-Cooled Hot Oil Pumps No Water Cooling Required RA296 RA3146 RA3186 RA296 The smaller, foot mounted economy version of the air-cooled RA series

More information

ITT. Goulds Pumps G&L Series NPO. Engineered for life. Commercial Water. Open Impeller All Stainless Steel End Suction Pumps.

ITT. Goulds Pumps G&L Series NPO. Engineered for life. Commercial Water. Open Impeller All Stainless Steel End Suction Pumps. ITT Goulds Pumps G&L Series NPO Open Impeller All Stainless Steel End Suction Pumps www.goulds.com Engineered for life A Full Range of Product Features NPO Product Line Numbering System Superior Materials

More information

Series: GNA5-1-1/4, GNA6-1-1/4

Series: GNA5-1-1/4, GNA6-1-1/4 1750 RPM - 60Hz. CAPACITIES TO 40 GPM (2.5 LPS) HEADS TO 0 FEET (9 m) USA: (97) 778-8947 Canada: (905) 457-622 International: (97) 615-598 1 500 RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 15 FEET

More information

Series: ET. 4ET RPM - 60Hz. ET RPM - 60Hz. (See Indivdual curves for symbol number)

Series: ET. 4ET RPM - 60Hz. ET RPM - 60Hz. (See Indivdual curves for symbol number) 4ET - 725 RPM - 60Hz. ET - 450 RPM - 60Hz. (See Indivdual curves for symbol number) ET - 2900 RPM - 50Hz. (See Indivdual curves for symbol number) 60 Hz Performance 60Hz - PERFORMANCE AND SELECTION CHART

More information

Industrial Pump Catalog

Industrial Pump Catalog Industrial Pump Catalog Contents Why Corken?........................................................................ i-5 About This Catalog...................................................................

More information

Series: ET. 4ET RPM - 60Hz. ET RPM - 60Hz. (See Indivdual curves for symbol number)

Series: ET. 4ET RPM - 60Hz. ET RPM - 60Hz. (See Indivdual curves for symbol number) 4ET - 725 RPM - 60Hz. ET - 450 RPM - 60Hz. (See Indivdual curves for symbol number) ET - 2900 RPM - 50Hz. (See Indivdual curves for symbol number) USA: (97) 77-947 Canada: (905) 457-622 International:

More information

THE LEADING FORCE behind liquids since 1857

THE LEADING FORCE behind liquids since 1857 THE LEADING FORCE behind liquids since 1857 High Capacity Bulk Liquid Handling Pumps - For loading/unloading transport truck tankers, railway tank cars, and barges - High flow rate transfer capability

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL TECHNICAL SERVICE MANUAL ABRASIVE LIQUID HEAVY-DUTY BRACKET MOUNTED PUMPS SERIES 4625 SIZES H - M SECTION TSM 410.2 PAGE 1 of 10 ISSUE C CONTENTS Introduction....................... 1 Special Information...................

More information

4" GRJ Internal Eccentric Gear Pump

4 GRJ Internal Eccentric Gear Pump 4" GRJ Internal Eccentric Gear Pump Performance: Flow rate 55 m 3 /h Pressure 1-14 bar Temperature 0-200 C Speed 400 d/d Viscosity 100-250000 SSU Technical Features: Internal eccentric gear pump 4 flanged

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL HEAVY-DUTY Stainless steel BRACKET MOUNTED PUMPS SERIES 127 AND 4127

More information

EAN PUMP SERIES DL200/DL230

EAN PUMP SERIES DL200/DL230 A Met-Pro Fluid Handling Technologies Business Combining the Resources of Dean Pump, Fybroc & Sethco DEAN PUMP SERIES DL200/DL230 Inline Centrifugal Process Pumps D A T A P A K Section DL200/DL230 SERIES

More information

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump Section 914 Page 101 Supersedes Section 913 Page 101 Dated November 1, 199p Application & Reference Data Typical Specifications Section 914 Section 914 Page 102 Supersedes Section 913 Page 102 Dated November

More information

Contents Project: Model: Chk d: Date:

Contents Project: Model: Chk d: Date: Contents Model DSHU6. DSHU6.7 DSHU6. DSU6. DSHU6. DSU6.7 DSHU6.7 8DSU6. 8DSHU6. 8DSU6.7 8DSHU6.7 DSU6. DSU67. Section Page Specifications -7, 8 Selection Chart -7., 8. Performance Curves -6 Outline Drawings

More information

ITT. Goulds Pumps. G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps. Engineered for life. Commercial Water.

ITT. Goulds Pumps. G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps. Engineered for life. Commercial Water. ITT Goulds Pumps G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps www.goulds.com Engineered for life A Full Range of Product Features Superior Materials of Construction: AISI Type 316L

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL HEAVY-DUTY STAINLESS STEEL PUMPS SERIES 724 AND 4724 SIZES H - LL

More information

Viking s helical gear reducers are available in three basic sizes, each size offering several gear ratios.

Viking s helical gear reducers are available in three basic sizes, each size offering several gear ratios. PARTS & ACCESSORIES: SIZES A, B & C Section 610 Page 610.1 Issue L Gear Ratio Range: (varies by reducer size) 1.87:1 to 7.95:1 Output Speeds (with 1750 rpm input) 950 to 220 rpm Reducer Horsepower Range:

More information

CONTENTS INTRODUCTION. Electronic copies of the most current TSM issue can be found on the Viking Pump website at

CONTENTS INTRODUCTION. Electronic copies of the most current TSM issue can be found on the Viking Pump website at Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL UNIVERSAL SEAL HEAVY DUTY PUMPS SERIES 124A, 4124A, 124AE, AND 4124AE

More information

EFQT/EFQU. EBARA Self Priming Trash Pump. Contents Project: Model: Chk d: Date:

EFQT/EFQU. EBARA Self Priming Trash Pump. Contents Project: Model: Chk d: Date: Contents Section Page Model Designation 2 Features 3 Standard Specifications 5 Specifications 6 Selection Chart 7 Suction Speed Flow Chart 9 Performance Curves 10 Dimension Drawings 20 Model Designation

More information

Sealless Mag Drive Pumps For Crucial Liquid Containment Applications

Sealless Mag Drive Pumps For Crucial Liquid Containment Applications Viking Mag Drive Pumps Sealless Mag Drive Pumps For Crucial Liquid Containment Applications Eliminates pump seal maintenance Highest level of liquid containment available Metric or U.S. Design Sizes in

More information

RS Multi-Stage, Ring Section Pumps

RS Multi-Stage, Ring Section Pumps RS Multi-Stage, Ring Section Pumps Technical Specification Pages This page left intentionally blank. 1.0 Overview. The RS Series is Carver s multi-stage pump for fluids at moderate to high pressures. The

More information

GENERAL OVERVIEW BRONZE PEDESTAL ROTARY GEAR N13HDM C992 BRONZE BRONZE HELICAL ROTOR 101BG RUBBER

GENERAL OVERVIEW BRONZE PEDESTAL ROTARY GEAR N13HDM C992 BRONZE BRONZE HELICAL ROTOR 101BG RUBBER GENERAL OVERVIEW BRONZE CLOSE COUPLED N970 BRONZE PEDESTAL N4000R BRONZE PEDESTAL ROTARY GEAR N13HDM PLASTIC CENTRIFUGAL 144 RUBBER ROLLER 310F BRONZE CENTRIFUGAL 50P DUCTILE IRON CLOSE COUPLED C992 BRONZE

More information

Pumps. KRAL Screw Pumps C Series. Quality, innovation and short lead times.

Pumps. KRAL Screw Pumps C Series. Quality, innovation and short lead times. Pumps KRAL Screw Pumps C Series. Quality, innovation and short lead times. www.kral-usa.com Pumps Our Legacy and Commitment. Tapping into over 60 years of experience in ever improving quality and customer

More information

D51 D61 D71 D91 Series

D51 D61 D71 D91 Series MTH PUMPS D51 D61 D71 D91 Series Page D-1 Capacities to 24 GPM Heads to 36 Feet Horizontal Close Coupled Close-coupled centrifugal pumps from MTH provide economical performance up to 24 GPM applications

More information

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps 1.0 Purpose A. The following guidelines apply to the selection of pumps primarily for circulating water. It is the goal of NC State to purchase pumps that are selected to provide a long service life, minimal

More information

THE LEADING FORCE behind liquids TM since Rotary Positive Displacement Pumps

THE LEADING FORCE behind liquids TM since Rotary Positive Displacement Pumps THE LEADING FORCE behind liquids TM since 1857 Rotary Positive Displacement Pumps External Gear 3600 Series General purpose pumps for transferring, mixing, blending and recirculating. Efficiently handles

More information

M50 L50 Series - 50Hz Metric Edition Multistage Regenerative Turbine Pumps

M50 L50 Series - 50Hz Metric Edition Multistage Regenerative Turbine Pumps Page M-M MTH PUMPS M L Series - Hz Metric Edition Multistage Regenerative Turbine Pumps Capacities to LPM Heads to 6 Meters Single or Multi-stage Units (up to stages) Vertical Close Coupled Horizontal

More information

Engineering Data Pack GlobalGear Series Pump US

Engineering Data Pack GlobalGear Series Pump US Engineering Data Pack GlobalGear Series Pump US Excellence at work. Excellence in life. Table of Contents GG015 - GG030 with Angle Ports (Flanged Only) Mounting Dimensions 3 IG015I - IG030I with Integral

More information