Fan Coil Units POWERED BY KLIMAK ITALY

Size: px
Start display at page:

Download "Fan Coil Units POWERED BY KLIMAK ITALY"

Transcription

1 Fan Coil Units POWERED BY KLIMAK ITALY

2

3 Index Chilled Water Fan Coil Unit Decorative Fan Coil... Concealed Ducted Fan Coil Unit (Low ESP)...11 Concealed Ducted Fan Coil Unit (Medium ESP)...1 Concealed Ducted Fan Coil Unit (High ESP)...19 Wiring Diagram of Fan Coil Unit...2 3

4 HC FC 03 M 1 DA

5 Decorative Fan Coil Specification

6 Decorative Fan Coil Unit Technical Data-Horizontal Unit Unit Model (1) Unit Performance Nom. Airflow Rate HDFC-02F HDFC-03F HDFC-0F HDFC-0F HDFC-0F HDFC-08F High Medium (L/S) Low External Static Pressure (Pa) Free Blow Noise Level (2) Physical Data Cooling Coil Size (3) Power Supply High < < <0 <8 <9 <3 Medium db(a) <3 < <7 < <7 <0 Low <0 <1 < < < <8 Fin Height (mm) Fin Length (mm) Coil Style 3/8" OD Copper Tube + Aluminum fins 12FPI Max. Working Pre Bar 220~20V/1PH/0HZ Motor Type 3-Speed Fan Motor Fan Motor Output (2) (w) Power (2) Consumption (w) Fan Blower Size (Dia x L) (mm) 10 x x x x x x 200 Fan Blower Type Double Inlet Forward Curved Centrifugal Fan Blower Chilled Water Connection Drainage Connection 1/2"MPT 3/"MPT Net Dimension () L x W x H (mm) 0 x 830 x 29 0 x 1080 x 29 0 x 130 x 29 Packing Dimension () L x W x H (mm) 80 x 900 x 3 80 x 110 x 3 80 x 110 x 3 Row Coil (Kg) Net Weight () Row Coil (Kg) Row Coil (Kg) Unit Model (1) Unit Performance Nom. Airflow Rate HDFC-10F HDFC-12F HDFC-1F HDFC-18F HDFC-20F High Medium (L/S) Low External Static Pressure (Pa) Free Blow Noise Level (2) Physical Data Cooling Coil Size (3) Power Supply High <9 <1 <3 <7 <9 Medium db(a) <8 <9 <0 < < Low < <7 <7 <1 <3 Fin Height (mm) Fin Length (mm) Coil Style 3/8" OD Copper Tube + Aluminum fins 12FPI Max. Working Pre Bar 20.0 Bar 220~20V/1PH/0HZ 220~20V/1PH/0HZ Motor Type 3-Speed Fan Motor 3-Speed Fan Motor Fan Motor Output (2) (w) Power (2) Consumption (w) Fan Blower Size (Dia x L) (mm) 10 x x x x x 200 Fan Blower Type Double Inlet Forward Curved Centrifugal Fan Blower Chilled Water Connection Drainage Connection 3/"MPT 3/"MPT Net Dimension () L x W x H (mm) 0 x 110 x 29 0 x 190 x 29 0 x 1870 x 29 0 x 1870 x 39 0 x 1870 x 39 Packing Dimension () L x W x H (mm) 80 x 180 x 3 80 x 170 x 3 80 x 190 x x 1900 x x 1900 x 30 Row Coil (Kg) Net Weight () Row Coil (Kg) Row Coil (Kg) Notes : (1) Unit Model differs in the extended letters indicating different cabinet construction, as per "unit model identification"; (2) Unit noise level & fan motor output are stated based on -row cooling coil, and can be different for units with other cooling coils; (3) 1/2" tubing coil are available for all models with different coil sizes; () Net Dimension are same for single skin and double skin unit; () Net weight stated are for single skin cabinet structure units with Aluminum Frame, and will be different for double skin units. Please add 3kg onto these weights in calculating the shipping weights.

7 Decorative Fan Coil Unit Dimensional Drawing Cable Water Outlet Water Inlet Drain Port Back View D (Installation Distance) C (Unit Length) B (Installation Distance) A (Unit Width) Top View C (Unit Length) 29 (Unit Height) E (Unit Height) Front View Side View Unit Model A B C D E HDFC-02F1SA/DA HDFC-03F1SA/DA HDFC-0F1SA/DA HDFC-0F1SA/DA HDFC-0F1SA/DA HDFC-08F1SA/DA HDFC-10F1SA/DA HDFC-12F1SA/DA HDFC-1F1SA/DA HDFC-18F1SA/DA HDFC-20F1SA/DA (Unit: mm) 7

8 R Decorative Fan Coil Unit KLIMAK Technical Data-Vertical Unit Unit Model VDFC-02F1 VDFC-03F1 VDFC-0F1 VDFC-0F1 VDFC-0F1 VDFC-08F1 VDFC-10F1 VDFC-12F1 VDFC-1F1 Unit Performance High Nom. Airflow Rate Medium (L/S) Low External Static Pressure (Pa) Free Blow High < < <0 <8 <9 <3 <9 <1 <3 Noise Level (1) Medium db(a) <3 < <7 < <7 <0 <8 <9 <0 Low <0 <1 < < < <8 < <7 <7 Physical Data Fin Height (mm) Fin Length (mm) Cooling Coil Size (2) Coil Style 3/8" OD Copper Tube + Hydrophilic Aluminum Fins 12FPI Max. Working Pre Bar Power Supply 220~20V/1PH/0HZ Motor Type 3-Speed Fan Motor Fan Motor Output (1) (w) Fan Blower Size (Dia x L) (mm) 10 x x x x x x x x x 200 Fan Blower Type Double Inlet Forward Curved Centrifugal Fan Blower Chilled Water Connection Drainage Connection 1/2"MPT 3/"MPT 3/"MPT Standard Dimension (3) L x W x H (mm) 878 x 29 x x 29 x x 29 x 93 1 x 29 x x 29 x x 29 x 93 Packing Dimension (3) L x W x H (mm) 90 x 320 x x 320 x 0 1 x 320 x 0 12 x 320 x x 320 x x 320 x 0 Row Coil (Kg) Net Weight () Row Coil (Kg) Row Coil (Kg) Notes: (1) Unit noise level & fan motor output are stated based on -row cooling coil, and can be different for units with other size cooling coils; (2) 1/2" OD copper tube cooling coils are also available for all models; (3) Standard dimension and packing dimension are stated based on 1mm thick closed cell foam insulation; () Net weights are stated for double skin units; Please add 3kg onto net weights in calculating the shipping data. Dimensional Drawing Return Air Grille A Unit Model Unit Model A VDFC-02F1 878 VDFC-08F1 138 VDFC-03F1 878 VDFC-10F1 1 VDFC-0F1 878 VDFC-12F1 170 Bottom View VDFC-0F VDFC-1F VDFC-0F (Unit: mm) A (Unit Length) 29(Unit Width) Front View Supply Air Grille (93 (Unit Height) 8 (Feet Height) 78 (Total Height) Side View Water Inlet Cable Water Outlet Drain Port BackView 8

9 Decorative Fan Coil Unit COOLING COIL PERFORMANCE - 3/8" TUBE Unit Model Rows of Coil Fan Speed HDFC-02F HDFC-03F HDFC-0F HDFC-0F HDFC-0F HDFC-08F Standard Application EWT/LWT. /11. Air On DBT/WBT 23 /1 High Delta T Application EWT/LWT. /1. Standard Application EWT/LWT. /11. Air On DBT/WBT 2 /18 High Delta T Application EWT/LWT. /1. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. (kw) (kw) (kw) (kw) (kw) (kw) (kw) (kw) High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low

10 Decorative Fan Coil Unit COOLING COIL PERFORMANCE - 3/8" TUBE Unit Model Rows of Coil Fan Speed HDFC-10F HDFC-12F HDFC-1F HDFC-18F HDFC-20F Standard Application EWT/LWT. /11. Air On DBT/WBT 23 /1 High Delta T Application EWT/LWT. /1. Standard Application EWT/LWT. /11. Air On DBT/WBT 2 /18 High Delta T Application EWT/LWT. /1. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. (kw) (kw) (kw) (kw) (kw) (kw) (kw) (kw) High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low

11 Concealed Ducted Fan Coil Unit (Low ESP) Specification Single / Double Skin Unit Cabinet Single skin: Casing made of 1.2mm powder coated galvanized steel sheets, internally insulated with 1mm closed cell foam insulation. Double skin: Casing made of 1.0mm outer and 0.mm inner powder coated galvanized steel sheets, with 1mm thick closed cell foam insulation. Option: Return air spigot with bottom withdrawal air filter (extra price). Fan Section Fan Motor: 3 speed fan motors with permanent split capacitor, thermal overload protection, and lifetime lubricated ball bearing. Fan Blower: DIDW forward curved centrifugal fan blower made of galvanized steel directly driven by fan motors. All fan blowers are statically and dynamically balanced. Coil Section Cooling Coils made out of 10mm or 12mm OD copper tubes mechanically bonded into aluminum fins, with copper header; fin thickness 0.1mm, with fin spacing 2.0mm (12FPI) Cooling coils are ARI rated. Drain Pan Drain pan made of powder coated galvanized steel along with auxiliary drain pan extending under valve package, insulated with closed cell foam. Option: Drain pan made of stainless steel (extra price). Filter Section 12mm thick polyester or aluminum return air filter assembled in aluminum frames provided for easy withdrawal and replacement. Heater Battery (Extra Price) PTC Electrical heater battery is supplied with inbuilt thermal protection for heating application on special requirement. 11

12 R Concealed Ducted Fan Coil Unit (Low ESP) KLIMAK Technical Data Unit Model Unit Performance HCFC-02L1 HCFC-03L1 HCFC-0L1 HCFC-0L1 HCFC-0L1 HCFC-08L1 HCFC-10L1 HCFC-12L1 HCFC-1L1 High (L/S) Nom. Airflow Rate Medium (L/S) Low (L/S) External Static Pressure (1) (Pa) Nominal 30 Pa (30~0Pa) High db(a) < <7 <1 <9 <1 <3 <1 <3 < Noise Level (2) Medium db(a) <3 < <9 <7 <8 <1 <8 <1 <2 Low db(a) <0 <2 <7 < < <0 < <8 <9 Physical Data Fin Height (mm) Cooling Coil Size (3) Fen Length (mm) Coil Style 3/8" OD Copper Tube + Hydrophilic Aluminum Fins 12FPI Max. Working Pre Bar Power Supply 220~20V/1PH/0HZ Motor Type 3-Speed Fan Motor Fan Motor Output (2) (w) Fan Blower Size (Dia x L) (mm) 10 x x x x x x x x x 200 Fan Blower Type Double Inlet Forward Curved Centrifugal Fan Blower Chilled Water Connection 3 Row Coil Inner 1/2"FPT - Outer 3/"MPT Inner 3/"FPT - Outer 1"MPT Drainage Connection 3/"MPT Standard Dimension() (mm) 7 x 92 x 20 7 x 1212 x 20 7 x 17 x 20 7 x x 1827 x 20 7 x 1997 x 20 Packing Dimension () (mm) 70 x 99 x x 123 x x 190 x x 170 x x 180 x x 2020 x 270 Row Coil (Kg) Net Weight () Row Coil (Kg) Row Coil (Kg) Notes: (1) External Static Pressure are measured based on Medium dirty polyster air fitler; (2) Unit noise level & fan motor output are stated based on -row cooling coil, and can be different for units with other size cooling coils; (3) 1/2 OD copper tube cooling coils are available with all models; () Standard dimension and packing dimension are stated based on 1mm thick closed cell foam insulation; () Please add 3kg onto net weights in calculating the shipping weights. Dimensional Drawing 2 7(Unit Length) (Coil Section) 191(Spigot Height) Water Outlet 10 Water Inlet 110 Junction. Box Air Filter 28(Unit Height) Side View Drain Port Front View Unit Model A B HCFC-02L1 92 HCFC-03L1 92 Drain Port HCFC-0L1 HCFC-0L1 HCFC-0L1 HCFC-08L1 HCFC-10L1 HCFC-12L1 HCFC-1L (Unit: mm) 7 A (Unit Width) B (Length of Drain Pan) 220 ( Width of Drain Pan) Top View 12

13 Concealed Ducted Fan Coil Unit (Low ESP) Concealed Ducted Fan Coil Unit (Low ESP) R KLIMAK COOLING COIL PERFORMANCE - 3/8" TUBE Unit Model HCFC-02L1 HCFC-03L1 HCFC-0L1 HCFC-0L1 HCFC-0L1 HCFC-08L1 HCFC-10L1 HCFC-12L1 HCFC-1L1 Air On DBT/WBT 23 /1 Air On DBT/WBT 2 /18 Standard Application EWT/LWT. /11. High Delta T Application EWT/LWT. /1. Standard Application EWT/LWT. /11. High Delta T Application EWT/LWT. /1. Rows Fan Speed T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. of Coil (kw) (kw) (kw) (kw) (kw) (kw) (kw) (kw) High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low

14 Concealed Ducted Fan Coil Unit (Medium ESP) Single Skin Unit Double Skin Unit Cabinet Single skin: Casing made of 1.2mm powder coated galvanized steel sheets, internally insulated with 1mm closed cell foam insulation. Double skin: Casing made of 1.0mm outer and 0.mm inner powder coated galvanized steel sheets, with 1mm thick closed cell foam insulation. Option 1: 2mm thick closed cell foam insulation (extra price). Option 2: For Hygienic unit, inner stainless steel sheet (extra price). Option 3: Return air spigot with bottom withdrawal air filter (extra price). Fan Section Fan Motor: 3 speed fan motors with permanent split capacitor, thermal overload protection, and lifetime lubricated ball bearing. Fan Blower. DIDW forward curved centrifugal fan blower made of galvanized steel directly driven by fan motors. All fan blowers are statically and dynamically balanced. Coil Section Cooling Coils made out of 10mm or 12mm OD copper tubes mechanically bonded into aluminum fins, with copper header, fin thickness 0.1mm, fin spacing 2.0mm (12FPI). Cooling coils are ARI rated. Drain Pan Drain pan made of powder coated galvanized steel along with auxiliary drain pan extending under valve package, insulated with closed cell foam. Option: Drain pan made of stainless steel (extra price). Filter Section 12mm thick polyester or aluminum return air filter assembled in aluminum frames provided for easy withdrawal and replacement. Heater Battery (Extra Price) PTC Electrical Heater Battery is supplied with inbuilt thermal protection for heating application on special requirement. 1

15 Concealed Ducted Fan Coil Unit (Medium ESP) Technical Data Unit Model Unit Performance HCFC-02M1 HCFC-03M1 HCFC-0M1 HCFC-0M1 HCFC-0M1 HCFC-08M1 HCFC-10M1 HCFC-12M1 HCFC-1M1 High (L/S) Nom. Airflow Rate Medium (L/S) Low (L/S) External Static Pressure (1) (Pa) Nominal 0 Pa (0~7Pa) High db(a) <7 <9 <0 <3 <3 <2 < < <7 Noise Level (2) Medium db(a) < <7 <8 <1 <0 <8 <3 <2 < Low db(a) <3 < < <8 < < <2 <9 <2 Physical Data Cooling Coil Size (3) Power Supply Fin Height (mm) Fen Length (mm) Coil Style 3/8" OD Copper Tube + Hydrophilic Aluminum Fins 12FPI Max. Working Pre Bar 220~20V/1PH/0HZ Motor Type 3-Speed Fan Motor Fan Motor Output (2) (w) Fan Blower Size (Dia x L) (mm) 180 x x x x x x x x x 190 Fan Blower Type Double Inlet Forward Curved Centrifugal Fan Blower Chilled Water Connection 1/2"FPT - 3/"MPT 3/"FPT - 1"MPT Drainage Connection 3/" MPT Net Dimension - Single Skin Unit 90 x 820 x x 920 x x 1170 x x 1220 x x 1370 x 10 () () () Net Dimension - Double Skin Unit (mm) 00 x 880 x 3 00 x 980 x 3 00 x 1230 x 3 72 x 1280 x 0 72 x 130 x 0 () Packing Dimension - Single Skin Unit 00 x 80 x x 90 x x 1200 x 30 7 x 120 x 0 7 x 100 x 0 () Packing Dimension - Double Skin Unit (mm) 1 x 910 x 10 1 x 1010 x x 120 x 10 7 x 1310 x 0 7 x 10 x 0 Row Coil (Kg) Net Weight () Row Coil (Kg) Row Coil (Kg) Unit Model Unit Performance Nom. Airflow Rate HCFC-18M1 HCFC-20M1 HCFC-2M1 HCFC-30M1 HCFC-3M1 HCFC-2M1 HCFC-8M1 HCFC-M1 High (L/S) Medium (L/S) Low (L/S) External Static Pressure (1) (Pa) Nominal 0 Pa (0~7Pa) High db(a) <8 <9 <71 <7 <7 <78 <79 <81 Noise Level (2) Medium db(a) < < <8 <71 <72 <7 <7 <77 Low db(a) <1 <2 < <9 <9 <71 <72 <7 Physical Data Cooling Coil Size (3) Power Supply Fin Height (mm) Fen Length (mm) Coil Style 3/8" OD Copper Tube + Hydrophilic Aluminum Fins 12FPI 1/2" OD Copper Tube + Hydrophilic Aluminum Fins 12FPI Max. Working Pre Bar 220~20V/1PH/0HZ 3-Speed Fan Motor Fan Motor Output (2) (w) Fan Blower Size (Dia x L) (mm) 200 x x x x x x x x 0 Fan Blower Type Double Inlet Forward Curved Centrifugal Fan Blower Chilled Water Connection 3/"FPT - 1"MPT 1-1/" MPT Drainage Connection 3/" MPT Net Dimension - Single Skin Unit 72 x 123 x 7 () () Net Dimension - Double () Skin Unit (mm) 72 x 123 x 7 82 x 123 x 0 82 x 19 x 0 89 x 18 x 0 99 x 18 x 1 99 x 1970 x 1 99 x 210 x 1 Packing Dimension - Single Skin Unit() 7 x 170 x 0 () Packing Dimension - Double Skin Unit (mm) 7 x 10 x x 170 x x 17 x x 189 x x 189 x 100 x 2020 x 100 x 220 x Net Weight () Motor Type Row Coil (Kg) Row Coil (Kg) Row Coil (Kg) Notes (1) External Static Pressure are measured based on Medium dirty polyster air fitler; (2) Unit noise level & fan motor output are stated based on -row cooling coil, and can be different for units with other size cooling coils; (3) 1/2" OD copper tube cooling coils are also available for all models; () Standard dimension and packing dimension are stated for single skin unit based on 1mm thick closed cell foam insulation; () Standard dimension and packing dimension are stated for double skin units based on 2mm thick closed cell foam insulation; () Please add 3kg onto net weights in calculating the shipping data. 1

16 H Concealed Ducted Fan Coil Unit (Medium ESP) Dimensional Drawing (Unit: mm) Aux Drain Pan Junction Box A Unit W idth B Spigot Length Front View C Spigot Height D Unit Height F Installation Distance Air Filter Water Outlet Water Inlet G Unit Length Drain Port Side View Spigot Depth MODEL A B C D E F G H HCFC- 02M1S HCFC- 03M1S HCFC- 0M1S HCFC- 0M1S HCFC- 0M1S HCFC- 08M1S HCFC- 10M1S HCFC- 12M1S HCFC- 1M1S HCFC- 18M1S HCFC- 20M1S E Installation Distance Top View Support Hook Single Skin Unit A Unit Width B Spigot Length G Total Length Aux Drain Pan Front View C Spigot Height D Unit Height Doouble Skin Uhit A Unit Width B Spigot Length Spigot Depth C Spigot Height D Unit Height Air Filter Water Outlet Water Inlet H Front View Drain Port Side View 20 F Installation Distance Air Filter Water Outlet Water Inlet Drain Port Side View H Spigot Depth MODEL A B C D E F G H HCFC- 02M1DA HCFC- 03M1DA HCFC- 0M1DA HCFC- 0M1DA HCFC- 0M1DA HCFC- 08M1DA HCFC- 10M1DA HCFC- 12M1DA HCFC- 1M1DA HCFC- 18M1DA HCFC- 20M1DA Junction Box E Installation Distance Top View ( Suspendi ng Hol e G Total Length Aux Drain Pan 10 Junction Box F Installation Distance MODEL HCF C- 2M1DA HCF C- 30M1DA HCF C- 3M1DA HCF C- 2M1DA HCF C- 8M1DA HCF C- M1DA A B C D E F G H Hole for suspension E (Installation Distance) Top View Single & Double Skin Unit 1

17 Concealed Ducted Fan Coil Unit (Medium ESP) COOLING COIL PERFORMANCE - 3/8" TUBE Unit Model HCFC-02M1 HCFC-03M1 HCFC-0M1 HCFC-0M1 HCFC-0M1 HCFC-08M1 HCFC-10M1 HCFC-12M1 HCFC-1M1 HCFC-18M1 Rows of Coil Air On DBT/WBT 23 /1 Air On DBT/WBT 2 /18 Standard Application EWT/LWT. /11. High Delta T Application EWT/LWT. /1. Standard Application EWT/LWT. /11. High Delta T Application EWT/LWT. /1. Fan Speed T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. (kw) (kw) (kw) (kw) (kw) (kw) (kw) (kw) High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low

18 Concealed Ducted Fan Coil Unit (Medium ESP) COOLING COIL PERFORMANCE - 1/2" TUBE Unit Model HCFC-20M1 HCFC-2M1 HCFC-30M1 HCFC-3M1 HCFC-2M1 HCFC-8M1 HCFC-M1 Air On DBT/WBT 23 /1 Air On DBT/WBT 2 /18 Standard Application EWT/LWT. /11. High Delta T Application EWT/LWT. /1. Standard Application EWT/LWT. /11. High Delta T Application EWT/LWT. /1. Rows T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. of Coil Fan Speed (kw) (kw) (kw) (kw) (kw) (kw) (kw) (kw) High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low

19 Concealed Ducted Fan Coil Unit (High ESP) Single Skin Unit Double Skin Unit Specification Cabinet Single skin: Casing made of 1.2mm powder coated galvanized steel sheets, internally insulated with 1mm closed cell foam insulation. Double skin: Casing made of 1.0mm outer and 0.mm inner powder coated galvanized steel sheets, with 1mm thick closed cell foam insulation. Option 1: 2mm thick closed cell foam insulation (extra price). Option 2: For Hygienic unit, inner stainless steel sheet (extra price). Option 3: Return air spigot with bottom withdrawal air filter (extra price). Fan Section Fan Motor: 3 speed fan motors with permanent split capacitor, thermal overload protection, and lifetime lubricated ball bearing. Fan Blower. DIDW forward curved centrifugal fan blower made of galvanized steel directly driven by fan motors. All fan blowers are statically and dynamically balanced. Coil Section Cooling Coils made out of 10mm or 12mm OD copper tubes mechanically bonded into aluminum fins, with copper header, fin thickness 0.1mm, fin spacing 2.0mm (12FPI). Cooling coils are ARI rated. Drain Pan Drain pan made of powder coated galvanized steel along with auxiliary drain pan extending under valve package, insulated with closed cell foam. Option: Drain pan made of stainless steel (extra price). Filter Section 12mm thick polyester or aluminum return air filter assembled in aluminum frames provided for easy withdrawal and replacement. Heater Battery (Extra Price) PTC Electrical Heater Battery is supplied with inbuilt thermal protection for heating application on special requirement. 19

20 Concealed Ducted Fan Coil Unit (High ESP) Technical Data Unit Model Unit Performance Nom. Airflow Rate HCFC-03H1 HCFC-0H1 HCFC-0H1 HCFC-0H1 HCFC-08H1 HCFC-10H1 HCFC-12H1 HCFC-1H1 High (L/S) Medium (L/S) Low (L/S) External Static Pressure (1) (Pa) Nominal 100 Pa (100~10Pa) High db(a) <0 <2 <3 < < <8 <70 <70 (2) Noise Level Medium db(a) <7 <8 <1 <3 <3 < < <7 Low db(a) < < <7 <0 <1 <1 <3 < Physical Data (3) Cooling Coil Size Power Supply Fan Motor Fan Blower Fin Height (mm) Fen Length (mm) Coil Style 3/8" OD Copper Tube + Hydrophilic Aluminum Fins 12FPI Max. Working Pre Bar 220~20V/1PH/0HZ Motor Type 3-Speed Fan Motor Output (2) (w) Size (Dia x L) (mm) 200 x x x x x x x 190 Fan Blower Type Double Inlet Forward Curved Centrifugal Fan Blower Chilled Water Connection Inner 1/2"FPT - Outer 3/"MPT 3/"FPT - 1"MPT Drainage Connection 3/" MPT Net Dimension - Single Skin Unit (mm) 90 x 820 x x 920 x x 1170 x x 1220 x x 1370 x 10 () () Net Dimension - Double Skin Unit (mm) 00 x 880 x 3 00 x 980 x 3 00 x 1230 x 3 72 x 1280 x 0 72 x 130 x 0 () Packing Dimension - Single Skin Unit (mm) 00 x 80 x x 90 x x 1200 x 30 7 x 120 x 20 7 x 100 x 0 () Packing Dimension - Double Skin Unit (mm) 1 x 910 x 10 1 x 1010 x x 120 x 10 7 x 1310 x 0 7 x 10 x 0 Row Coil (Kg) Net Weight () Row Coil (Kg) Row Coil (Kg) Unit Model Unit Performance HCFC-18H1 HCFC-20H1 HCFC-2H1 HCFC-30H1 HCFC-3H1 HCFC-2H1 HCFC-8H1 HCFC-H1 High (L/S) Nom. Airflow Rate Medium (L/S) Low (L/S) External Static Pressure (1) (Pa) Nominal 100 Pa (100~10Pa) High db(a) <71 <72 <7 <77 <78 <80 <82 <8 Noise Level Medium db(a) < <8 <71 <7 <7 <7 <79 <79 (2) Low db(a) <3 < <9 <72 <72 <72 <7 <7 Physical Data (3) Cooling Coil Size Power Supply Fin Height (mm) Fen Length (mm) Coil Style 3/8" OD Copper Tube + Hydrophilic Aluminum Fins 12FPI 1/2" OD Copper Tube + Hydrophilic Aluminum Fins 12FPI Max. Working Pre Bar 220~20V/1PH/0HZ Motor Type 3-Speed Fan Motor Fan Motor Output (2) (w) Fan Blower Size (Dia x L) (mm) 200 x x x x x x x 30 Fan Blower Type Double Inlet Forward Curved Centrifugal Fan Blower Chilled Water Connection 3/"FPT - 1"MPT 1-1/" MPT Drainage Connection 3/" MPT Net Dimension - Single Skin Unit (mm) 72 x 123 x 7 () () Net Dimension - Double Skin Unit (mm) 72 x 123 x 7 82 x 123 x 0 82 x 19 x 0 89 x 18 x 0 99 x 18 x 1 99 x 1970 x 1 99 x 210 x 1 () Packing Dimension - Single Skin Unit (mm) 7 x 170 x 0 () Packing Dimension - Double Skin Unit (mm) 7 x 10 x x 170 x 0 80 x 17 x x 189 x x 189 x x 2020 x x 220 x 3 Row Coil (Kg) Net Weight () Row Coil Row Coil (Kg) Notes: (1) External Static Pressure are measured based on Medium dirty polyster air fitler; (2) Unit noise level & fan motor output are stated based on -row cooling coil, and can be different for units with other size cooling coils; (3) 1/2" OD copper tube cooling coils are also available for all models; () Standard dimension and packing dimension are stated for single skin unit based on 1mm thick closed cell foam insulation; () Standard dimension and packing dimension are stated for double skin units based on 2mm thick closed cell foam insulation; () Please add 3kg onto net weights in calculating the shipping data. 20

21 H Concealed Ducted Fan Coil Unit (High ESP) Dimensional Drawing (Unit: mm) Aux Dra in Pan Jun ction Box A Unit Wid th B Spigo t Len gt h Front View C Spigot Height D Unit Height 3(Hook) 70 F Installation Dis tan ce Air Filter Water Out let Water Inle t G Unit Leng th Dra in Port Side View Spigot Depth MODEL A B C D E F G I HCFC-03 H1S HCFC-0 H1S HCFC-0 H1S HCFC -0 H1S HCFC-08 H1S HCFC-10 H1S HCFC -12 H1S HCFC -1 H1S HCFC -18 H1S HCFC -20 H1S E Ins ta lla tion D istanc e Suppo rt Hook Top View Single Skin Unit A Unit Width B Spigot Length G Total Len gth 20 Aux Dra in Pan Jun ction Box Front View C Spigot Height D Unit Height F Installation distance Air Filter Water Out let Water Inle t Dra in Port Side View H Spigot D ept h MODEL A B C D E F G I HCFC-03H1DA HCFC-0H1DA HCFC-0H1DA HCFC-0H1DA HCFC-08H1DA HCFC-10H1DA HCFC-12H1DA HCFC-1H1DA 130 HCFC-18H1DA 123 HCFC-20H1DA E Hole Dista nce Top View for suspension Hole Double Skin Unit A Unit Width B Spig ot Le ngt h G ( Total Len gth) 30 ( Spigo t Depth ) C Spigot Height D Unit Height Air Filter Water Out let Water Inle t H Front View 20 Dra in Port Side View Aux Dra in Pan F Installation Distance MODEL A B C D E F G H HCFC-2H1DA HCFC-30H1DA HCFC-3H1DA HCFC-2H1DA HCFC-8H1DA HCFC-H1DA Jun ction Box E (Installation Distance) Hole for suspension Top View Single & Double Skin Unit 21

22 Concealed Ducted Fan Coil Unit (High ESP) COOLING COIL PERFORMANCE - 3/8" TUBE Unit Model HCFC-03H1 HCFC-0H1 HCFC-0H1 HCFC-0H1 HCFC-08H1 HCFC-10H1 HCFC-12H1 HCFC-1H1 HCFC-18H1 Air On DBT/WBT 23 /1 Air On DBT/WBT 2 /18 Standard Application EWT/LWT. /11. High Delta T Application EWT/LWT. /1. Standard Application EWT/LWT. /11. High Delta T Application EWT/LWT. /1. Rows Fan Speed T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. of Coil (kw) (kw) (kw) (kw) (kw) (kw) (kw) (kw) High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low

23 Concealed Ducted Fan Coil Unit (High ESP) COOLING COIL PERFORMANCE - 1/2" TUBE Unit Model HCFC-20H1 HCFC-2H1 HCFC-30H1 HCFC-3H1 HCFC-2H1 HCFC-8H1 HCFC-H1 Air On DBT/WBT 23 /1 Air On DBT/WBT 2 /18 Standard Application EWT/LWT. /11. High Delta T Application EWT/LWT. /1. Rows Standard Application EWT/LWT./11. High Delta T Application EWT/LWT. /1. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. of Coil Fan Speed (kw) (kw) (kw) (kw) (kw) (kw) (kw) (kw) High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low High Medium Low

24 PTC HEATER Wiring Diagram of Fan Coil Unit Wiring Diagram HIGH SPEED (RED) MEDIUM SPEED (BLUE) LOW SPEED (BLACK) NEUTRAL (YELLOW) M1 YELLOW/GREEN YELLOW/GREEN C1 C2 M2 YELLOW/GREEN HIGH SPEED (RED) MEDIUM SPEED (BLUE) LOW SPEED (BLACK) NEUTRAL (YELLOW) M1 YELLOW/GREEN YELLOW/GREEN C1 H M L N(L2) (G) H M L N(L2) (G) TO CONTROL SIGNAL ONE FAN MOTOR UNIT TO CONTROL SIGNAL TWO FAN MOTOR UNIT ELECTRICAL WIRING OF FCU UNITS WITHOUT ELEC. HEATER AC RELAY PTC THERMAL HT N HIGH SPEED (RED) MIDDLE SPEED (BLUE) LOW SPEED (BLACK) NEUTRAL (YELLOW) M1 H M L N(L2) (G) C1 YELLOW/GREEN YELLOW/GREEN C2 M2 YELLOW/GREEN AC RELAY PTC THERMAL PTC HEATER HT N HIGH SPEED (RED) MIDDLE SPEED (BLUE) LOW SPEED (BLACK) NEUTRAL (YELLOW) M1 H M L N(L2) (G) YELLOW/GREEN C1 YELLOW/GREEN TO CONTROL SIGNAL ONE FAN MOTOR UNIT TO CONTROL SIGNAL TWO FAN MOTOR UNIT ELECTRICAL WIRING OF FCU UNITS WITH ELEC. HEATER 2

25 OUR CONTACTS Navy Housing To Riyadh To Kharj Str. #170 Fuel Tanks Str. #9 Power Station Entrance No.: 1 For Riyadh 2 nd Industrial Area Visit our office: Riyadh - Head Office Industrial Area II - Riyadh Kingdom of Saudi Arabia refer to the map Or contact us at: PO Box: 1300 Riyadh 11 Kingdom of Saudi Arabia Tel: Fax: sales@safid.com Or visit our website: 2

26

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS DECORATIVE FAN COIL SPECIFICATIONS UNIT CABINET Single skin or double skin casing (inner perforated sheet or flat sheet) made of powder coated galvanized steel assembled in aluminum extrusion profiles,

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

The World Leading Air-conditioning Company

The World Leading Air-conditioning Company The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040

More information

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter INTRODUCTION GENERL DESCRIPTION Ducted Direct Drive Fan Coil ir Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free

More information

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS ACWL Series ACWL0 thru ACWL4 00 CFM thru 400 CFM GE_ACWL_series.indd 3// : PM CONTENTS Model decoding 3 Unit features 3 Standard specifications 3-4

More information

Technical Sales Guide # 040 YDFC 0 1 Page 2

Technical Sales Guide # 040 YDFC 0 1 Page 2 17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows

More information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option 42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 10 cfm Electric heater option 42DC/ 42DCD Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 0 to 00 cfm Electric heater

More information

CHILLED WATER FAN-COIL UNITS

CHILLED WATER FAN-COIL UNITS 40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Address: VTS Clima L.L.C.

Address: VTS Clima L.L.C. Address: VTS Clima L.L.C. Business Bay, Churchill Tower, Office 2409, P.O.Box#76849 Dubai, UAE phone: +971 (4) 443 91 20 fax: +971 (4) 443 96 20 e-mail: dubai@vtsgroup.com www.uae.vtsgroup.com Index VTS

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

CHILLED WATER DUCTED FAN COIL

CHILLED WATER DUCTED FAN COIL SD CHILLED WATER DUCTED AN A Series B Series (Double Skin) General abricated with a rigid galvanized steel casing. The DIDW centrifugal fans have balanced, galvanized steel, and forward curved blades.

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

PHCD-Series. Catalog

PHCD-Series. Catalog PCD-Series Catalog odel: PCD Introduction PCD fan coil unit is designed for a fully concealed ceiling installation. The external static pressure(esp) is up to 75Pa. Owing to its low static and low noise,

More information

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application 42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4 Fan coil units HFCE, HFXE, VFCE, VFXE series Sizes 03 to 20-300 to 3400 m3/h 2012 Trane Contents Features and Benefits 4 Model Nomenclature 5 Performance Data 7 Capacities 9 Dimensional data 19 Typical

More information

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed

More information

HIGH STATIC FAN COIL UNITS

HIGH STATIC FAN COIL UNITS STATIC FAN COI UNITS District Cooling Chilled Water Application TECNICA CATAOGUE (DUCTED TYPE) GFC - D SERIES COOING CAPACITY RANGE: 10,407 TO 66,329 BTU/R CASSIFIED INSUATION & FITER EDIA GFC-D-TC-10-13

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE Model: YSHW-DD 00784VIP Introduction YORK DIRECT DRIVE FAN COIL UNITS The YORK Fan Coil Unit is designed for many exposed and concealed applications.

More information

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series. Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...

More information

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0

More information

FCVC Series VERTICAL FAN COILS

FCVC Series VERTICAL FAN COILS VERTICAL FAN COILS The FCVC is designed for concealed, wall mounted installations with flexible heating/ cooling loads and minimal duct requirements. With a variety of options, such as fiber free insulation,

More information

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed

More information

High Static Fan Coil Units YDFC

High Static Fan Coil Units YDFC Static Fan Coil Units YDFC Contents contents Product information...3 Nomenclature & features...4 Features & benefits...4 Product details...5 Technical specifications...6 Unit dimensions ST type...7 Unit

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

GENERAL ELECTRIC FAN COIL UNITS

GENERAL ELECTRIC FAN COIL UNITS GENERAL ELECTRIC FAN COIL S Chilled Water System CFM thru CFM GE_AWHE_series.indd 3/6/ 3:3 PM GE_AWHE_series.indd 3/6/ 3:3 PM CONTENTS Outstanding features 4 Model decoding 5 A pplications 5 Physical data

More information

Commercial Blower Coil Air Handlers

Commercial Blower Coil Air Handlers Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration

More information

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001 42CHS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM QMS 001 World's No.1 Air Conditioning Expert www.carrier.co.th 42CHS-W Series Furred-in ceiling model 400-2000

More information

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered

More information

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Engineering Data ED-FWW-201501 Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz) Models: FWW200 FWW300 FWW400 FWW600 FWW800 FWW1000 FWW1200 FWW1400 FWW1600 FWW1800 Air Flow: 360-3020m 3 /h DAIKIN

More information

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool

More information

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

Submittal. Front View Side View

Submittal. Front View Side View RBHO Horizontal Low Profile Concealed Free Return Submittal FCU-RBHO-1.0 07-25-18 Top View (Drain Pan Omitted) Bottom View Front View Side View Left hand unit shown. All dimensions are inches [millimeters].

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499] BC--1.0 03-01-1 Belt Drive Blower Coil Unit, Basic Unit Discharge ARGT. 1 4. See page 1 for filter rack details. 5. Base rail is optional on he base unit. See page 13. Base rails must be used with mixing

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3 MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model

More information

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5 TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum

More information

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low

More information

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

Product Data. 42D Ducted Fan Coil Air Conditioners cfm Product Data 42D Ducted Fan Coil Air Conditioners 600-2000 cfm Carrier s 42D series ducted fan coil units offer design and equipment location flexibility Choice of 5 models, each available in 8 sizes For

More information

High Static Pressure Duct Fan Coil Unit

High Static Pressure Duct Fan Coil Unit MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4

More information

IDENTIFICATION ACCESSORIES DESCRIPTION

IDENTIFICATION ACCESSORIES DESCRIPTION Sentinel Doorway mounted air curtain. 1000mm, 1500mm & 2000mm widths. 1800 to 2700mm mounting height. Soffit drop rod or wall bracket mounted. Ambient air, 3 phase electric or LPHW heating. 1 IDENTIFICATION

More information

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A Chassis panelwork is all In House manufactured from nominally 1.2mm Galvanised steel. Where at all possible, flanges are formed inward facing to prevent exposure to bare metal edges. Sufficient forms and

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

BHH Product Specifications

BHH Product Specifications BHH Product Specifications HORIZONTAL BELT DRIVE DIRECT EXPANSION BLOWER COIL UNITS ALL S 3, 4, and 5 Ton 208/230 3 60 and 460 3 60 supply voltage Units are ETL listed to U.S. and Canadian safety standards

More information

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778] FCU-THBP-1.0 08-22-18 THBP Horizontal Low Profile Plenum Return Top View (Drain Pan Omitted) Bottom View Front View Left hand unit shown. All dimensions are inches [millimeters]. Side View Unit Size A

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

Low Static Pressure Duct(V shape evaporator)

Low Static Pressure Duct(V shape evaporator) Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...

More information

Vertical Floor Fan Coil Unit (Model FW)

Vertical Floor Fan Coil Unit (Model FW) Technical Bulletin Issue Date March 24, 2005 Vertical Floor Fan Coil Unit (Model FW) Figure 1: Model FWX Vertical Exposed Model FW Vertical Floor fan coil units are designed to maximize flexibility of

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL Centrifugal fan coil units SYSCOIL Fan coil units Compact, slim fan coil units. Available

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING SIZES FROM 600 TO 9,000 All Technical Specifications are Subject to Change without Notice.

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units Chiller Close Control Water terminals SYSCASSETTE Water cassette units SYSCASSETTE Water cassette Available accessories Available in 8 different sizes and 2 versions. Due to its square design these units

More information

Engineering Data Book

Engineering Data Book 40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Engineering Data Book

Engineering Data Book 40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature

More information

MODULAR AIR HANDLING UNITS GAH SERIES

MODULAR AIR HANDLING UNITS GAH SERIES MODULAR AIR HANDLING UNITS GAH SERIES 15 Models with Air Flows from 2,250 Cu.m/hr upto 77,800 Cu.m/hr Suitable for both Standard and District Cooling Applications GAH-TC-10-13 CONTENTS Design 2 Various

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

HEATING & COOLING COIL PRODUCTS

HEATING & COOLING COIL PRODUCTS HEATING & COOLING COIL PRODUCTS CC CEILING MOUNTED COOLERS Capacities 10-135k hite powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing HEATING & COOLING COIL PRODUCTS The CC range of ceiling mounted

More information

Low Static Pressure Duct (V shape evaporator)

Low Static Pressure Duct (V shape evaporator) MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...

More information

Prepared By : Checked By : Approved By : Page 1 out of 6

Prepared By : Checked By : Approved By : Page 1 out of 6 Software Name Carrier AHU - Version 1.0, Patch R1.1X UNIT MODEL GENERAL SPECIFICATIONS GENERAL LOCATION / WEIGHT UNIT DIMENSION Configuration : Quick Selection Wizard Unit Orientation : Horizontal Box

More information

Chilled Water Fan Coil Unit. DCBL VAV Stepless FCU Model : HFCF02~HFCF14

Chilled Water Fan Coil Unit. DCBL VAV Stepless FCU Model : HFCF02~HFCF14 Chilled Water Fan Coil Unit VV Stepless FCU Model : HFCF02~HFCF Features and Benefits ew Features Variable irflow & ccurate Control fan coil unit features variable airflow in addition to accurate temperature

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

42HS Fan Coil Unit (High Static Pressure)

42HS Fan Coil Unit (High Static Pressure) 42S Fan Coil Unit (igh Static Pressure) Air Volume: 1360~3400m3/h Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

Ceiling Concealed Chilled Water Fan Coil Unit

Ceiling Concealed Chilled Water Fan Coil Unit Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...

More information

Vertical Hi-Rise Fan Coil Unit (Model FS)

Vertical Hi-Rise Fan Coil Unit (Model FS) Technical Bulletin Issue Date March 1, 2005 Vertical Hi-Rise Fan Coil Unit (Model FS) Model FS Vertical Hi-Rise fan coil units are designed to maximize flexibility of selection and installation. The units

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT SIZES FROM 600 TO 4,000 All Technical Specifications are Subject to Change without Notice.

More information

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION UH Series abinet Unit Heaters TM HEAT TRANSFER DIVISION UH SERIES ABINET UNIT HEATERS ROUGHING IN DIMENSIONS TYPIAL ARRANGEMENTS B B 1 1/" (38) REESSING FRAME B 1 1/" (38) REESSING FRAME FULLY EXPOSED

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

Hi-Performance Series Fan Coil Technical Catalog

Hi-Performance Series Fan Coil Technical Catalog Hi-Performance Series Fan Coil Technical Catalog HYB Horizontal Hideaway Furred-in with galvanized finish for ducted/high static applications in drop-ceilings or over-closets. (600-2000 CFM) HGC Horizontal

More information

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS MAGIC AIRE BVX SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC COMPANY,

More information

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM 42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11 AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal

More information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping

More information

Modular Variable Speed Air Handlers

Modular Variable Speed Air Handlers Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A

More information

FN Fan-Coil Units High-Performance, Horizontal

FN Fan-Coil Units High-Performance, Horizontal FN Fan-Coil Units High-Performance, Horizontal Model FNX Exposed-Cabinet Dimensional Data Notes: 1. All dimensions are in inches [mm] and are +/- 1/8" [3 mm]. Metric values are soft conversions. 2. See

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL COIL UNITS MAGIC AIRE FFW/FSW/FHW/FHW SERIES COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. UNITED ELECTRIC

More information

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE Low Power Consumption, Accessible, & FW and FL Fan-Coil Design Features Owners Owners can choose between a standard height (FW)

More information