Advance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES

Size: px
Start display at page:

Download "Advance Information SPLIT SYSTEM HEAT PUMP 10 SEER. ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION FEATURES"

Transcription

1 TG1Y (1095) Advance Information SPLIT SYSTEM HEAT PUMP 10 S ERA 018 thru thru 5 NOMINAL TONS DESCRIPTION The ERA series heat pumps are designed for use with a variety of YORK evaporator sections to suit any application need. A full line of matching Add-On Coils are available for use with upflow, downflow or horizontal furnaces. Matching Air Handlers are also available for upflow, downflow or horizontal installation to provide a complete system. Electric heat may be installed in air handlers. All units are factory charged to assure easy installation. FEATURES DURABLE CONSTRUCTION - The outdoor unit is constructed of pre-painted steel that offers tough protection against corrosion and resists fading when exposed to sunlight. Drain holes are incorporated into the base pan to permit free drainage of moisture. QUALITY - The black outdoor coil is constructed of copper tube and aluminum fins for durability. Coil guard provides additional protection when installed in a heavy traffic area. PROTECTED COMPRESSOR - The hermetic compressor is internally protected against high pressure and temperature by the simultaneous operation of a high pressure relief valve and temperature sensors which stop the compressor if operating temperatures go too high. Both protectors reset automatically. TIME TEMPERATURE DEFROST CONTROL - Provides defrost including field selectable time periods between cycles (30, 60, 90 minutes). LOW OPERATING SOUND LEVEL - The compressor is mounted on rubber isolators to reduce operating sounds. The slow moving condenser fan keeps air turbulence and sound to a low level. EASY ACCESS - Removable panel affords accessibility to the electrical box. FACTORY TESTED - to verify system operation and control functioning before shipment. FULLY CHARGED AND FACTORY WIRED - to simplify installation and reduce labor costs. Only power supply and control wiring and refrigerant lines must be connected. All models are sweat connect with re-usable service valves. U.L. AND C.U.L. LISTED - approved for outdoor application. ARI CERTIFIED - to comply with ARI standard 240 and 270 for rating air cooled heat pump units. SINGLE PHASE - one (1) year limited parts warranty to original registered owner. Five (5) year warranty for compressor. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

2 TG1Y CAPACITY - With Air Handler Coils AIR HANDLER 2 ELECTRIC HEAT W 2 1 Phase ERA / NAH & NFA E1RA 018 N2AHD10 5,8,10,13,15 16 G3HC E1RA 024 N2AHD10 5,8,10,13,15 16 G3HC E1RA 030 N2AHD10 5,8,10,13,15 16 G3HC N4AHD14 5,10,15,20,25 22 G3HC E1RA 036 N4AHD14 5,10,15,20,25 22 G3HC N4AHD14 5,10,15,20,25 22 G3HC N4AHD16 8,10,15,20,25,30 26 G3HC E1RA 048 N4AHD16 8,10,15,20,25,30 G3HC N4AHD20 8,10,15,20,25,30 G3HC E1RA 060 N4AHD20 8,10,15,20,25,30 26 G3HC S AIR HANDLER 2 ELECTRIC HEAT W 1 Phase ERA / F1RP / F1FP E1RA 018 F1RP024 5, 7.5, E1RA 024 F1RP030 5, 7.5, E1RA 030 F1RP036 5, 7.5, 10, E1RA 036 F1RP036 5, 7.5, 10, Rated in accordance with DOE test procedures (Federal Register ) and ARI Standards 240 and 270. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 for blower motor. (Energy Efficiency Ratio) is the total cooling output in BTU s at a 95 F outdoor ambient divided by the total electric power in watthours at those conditions. S (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1 TXV = Thermal Expansion Valve Kit. Must be used with Hard Start Kit Accessory. 2 To meet Florida R=4.2 insulation code requirements, substitute N1FA, N3FA for N2AH, N4AH, G1FC for G3HC AND F1FP FOR F1RP models. All ratings remain the same. 3 P2MP, P2DP, and P2UR furnaces and F1RP air handlers have B.O.D. standard. P1SP furnace requires B.O.D. accessory (2FD ). ** Field transition may be required. = Not Applicable. S 2 Unitary Products Group

3 CAPACITY - With 80% Furnace and Coils FURNACE # MBH W 1 Phase ERA / UPFLOW FURNACE & S E1RA 018 P2MPD G3UA P2MPD G3UA P2MPD E1RA 024 P2MPD G3UA P2MPD P2MPD G3UA P2MPD E1RA 030 P2MPD G3UA P2MPD G3UA P2MPD P2MPD G3UA E1RA 036 P2MPD P2MPD G3UA P2MPD P2MPD P2MPD P2MPD G3UA P2MPD P2MPD P2MPD P2MPD G3UA E1RA 048 P2MPD P2MPD20 3 P2MPD P2MPD G3UA P2MPD P2MPD G3UA P2MPD E1RA 060 P2MPD G3UA P2MPD G3UA See Notes on Page 2 S TG1Y Unitary Products Group 3

4 TG1Y CAPACITY - With 90% Furnace and Coils FURNACE # MBH W 1 Phase ERA / UPFLOW FURNACE & S E1RA 018 P2URD P2URD G3UA P2URD E1RA 024 P2URD G3UA P2URD G3AU P2URD G3UA036 E1RA 030 P2URD P2URD G3UA037 P2URD G3AU E1RA 036 P2URD G3UA037 P2URD P2URD P2URD G3UA P2URD P2URD P2URD G3UA E1RA F048 P2URD P2URD P2URD G3UA E1RA 060 P2URD G3UA060 P2URD G3UA See Notes on Page 2 CAPACITY - With 78% Furnace and Coils FURNACE # MBH W 1 Phase ERA / UPFLOW FURNACE & S E1RA 018 P1SPD G3UA P1SPD G3UA P1SPD12 E1RA P1SPD G3UA E1RA 030 P1SPD G3UA P1SPD G3UA E1RA 036 P1SPD G3UA P1SPD G3UA P1SPD G3UA P1SPD P1SPD G3UA E1RA P1SPD G3UA E1RA 060 P1SPD G3UA S S 4 Unitary Products Group

5 CAPACITY - With 80% Furnace and Coils FURNACE # MBH W 1 Phase ERA / HORIZONTAL FURNACE & S E1RA 024 P2HED12 40 ** 60 ** P1HDD12 47 ** 69 ** G3HC E1RA 030 P2HED12 40 ** 60 ** G3HC030 P1HDD12 47 ** G3HC ** P2HED12 40 ** 60 ** P2HED16 80 ** E1RA 036 G3HC ** P1HDD12 69 ** P1HDD16 92 ** P2HED16 80 ** P2HED ** P1HDD16 92 ** G3HC P1HDD ** P2HED16 80 ** E1RA 048 P2HED ** G3HC P1HDD16 92 ** G3HC P1HDD ** E1RA 060 P2HED ** P2HDD ** G3HC Phase ERA/ HORIZONTAL FURNACE AND S E1RA 018 P2MPD G3HC E1RA 024 P2MPD G3HC E1RA 030 P2MPD G3HC030 P2MPD G3HC E1RA 036 P2MPD P2MPD16 64, G3HC P2MPD16 64, P2MPD G3HC042 P2MPD P2MPD G3HC048 P2MPD16 64, G3HC P2MPD20 80, G3HC E1RA G3HCO P2MPD G3HC P2MPD20 80, E1RA 060 P2MPD20 96 G3HC P2MPD See Notes on Page 2. S TG1Y Unitary Products Group 5

6 TG1Y CAPACITY - With 80% / 90% Furnace and Coils (continued) E1RA 018 E1RA 024 E1RA 030 E1RA 036 E1RA 048 E1RA 060 See Notes on Page 2 FURNACE # MBH P2DPD10 48 P2CDD10 57 P2CDD10 57 P2DPD10 48 P2DPD12 64 P2CDD12 76 P2DPD12 80 P2DPD10 48 P2DPD12 64 P2DPD10 80 P2CDD10 57 P2CDD12 76 P2DPD12 76 P2DPD12 80 P2DPD16 91 P2DPD16 95 P2CDD12 76 P2CDD16 95 P2DPD P2DPD16 95 P2CDD16 95 P2DPD16 80 P2DPD16 92 P2DPD P2DPD P2CDD16 95 P2DPD P2DPD P2CDD W 1 Phase ERA / DOWNFLOW FURNACE & S S 16 G3CN G3CN G3CN G3CN G3CN G3CN G3CN ARI SOUND RATINGS (ARI Standard 270) ERA SOUND RATINGS BELS E1RA CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI 6 Unitary Products Group

7 HEATING CAPACITY - With Air Handler Coils E1RA 018 E1RA 024 E1RA 030 E1RA 036 E1RA ARI HEATING 2 OUTDOOR TEMP 3 HSPF 47 F 17 F -3 F 7 F 17 F 27 F 37 F 47 F 57 F MBH COP MBH COP STD MBH MBH MBH MBH MBH MBH MBH 1 Phase ERA / AIR HANDLERS & S G3HC024 G1FC F1RP024 F1FP G3HC030 G1FC F1RP030 F1FP G3HC030 G3HC036 G1FC G1FC036 F1RP036 F1FP G3HC042 G1FC F1RP042 F1FP G3HC042 G3HC048 G1FC G1FC048 G3HC G1FC048 G3HC G1FC060 E1RA 060 G3HC G1FC060 1 Rated same as for cooling. 2 Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. 3 Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. COP equals MBH output divided by (total input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. = Not Applicable TG1Y Unitary Products Group 7

8 TG1Y HEATING CAPACITY - With Furnace Coils 1 ARI HEATING 2 OUTDOOR TEMP 3 47 F 17 F HSPF -3 F 7 F 17 F 27 F 37 F 47 F 57 F MBH COP MBH COP MBH MBH MBH MBH MBH MBH MBH 1 Phase ERA / UPFLOW FURNACE & S E1RA 018 G3UA G3UA E1RA 024 G3UA036 G3UA E1RA 030 G3UA036 G3UA G3UA E1RA 036 G3UA G3UA G3UA E1RA 048 G3UA060 G3UA E1RA 060 G3UA060 G3UA Phase ERA / DOWNFLOW FURNACE & S E1RA 018 G3CN E1RA 024 G3CN E1RA 030 G3CN E1RA 036 G3CN G3CN E1RA 048 G3CN E1RA 060 G3CN Rated same as for cooling. 2.Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. 3 Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. COP equals MBH output divided by (total input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. = Not Applicable. 8 Unitary Products Group

9 DIMENSIONS TG1Y All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. ERA REFRIGERANT DIMENSIONS CONNECTION LINE SIZE A 1 B C LIQUID VAPOR Includes fan guard PHYSICAL AND ELECTRICAL DATA - (1 Phase) E1RA E1RA E1RA E1RA E1RA E1RA E1RA SUPPLY VOLTAGE 208/ NORMAL VOLTAGE RANGE to 252 MIN. CIRCUIT AMPACITY MAX. OVERCURRENT DEVICE AMPS COMPRESSOR TYPE RECIP RECIP INERTIA INERTIA RECIP SCROLL SCROLL COMPRESSOR AMPS LOAD LOCKED ROTOR CRANKCASE HEATER YES YES YES NO YES NO NO FAN MOTOR AMPS LOAD MIN. FIELD WIRE SIZE - AWG/LENGTH(ft) 12 / / / / / C COPPER CONDUCTORS, 230V 10 / / / / / / / 0-44 FAN DIAMETER INCHES HP FAN MOTOR NOMINAL RPM 1,100 1,100 1,100 1, NOMINAL 1,850 1,850 2,750 2,750 3,150 3,150 3,350 FACE AREA SQ. FT ROWS DEEP FIN / INCH LIQUID LINE OD VAPOR LINE OD CHARGE, LBS CHARGE PER FOOT, oz OPERATING WEIGHT, LBS Utilization range A in accordance with ARI standard 110. Dual element fuses or HACR circuit breaker. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant calculated, using the difference in length multiplied by the per foot value. Unitary Products Group 9

10 TG1Y TYPICAL INSTALLATION - ERA 018 THRU 030 TYPICAL POWER WIRING TYPICAL FIELD WIRING E1RA SERIES HEAT PUMPS LOW VOLTAGE WIRING - E1RA HEAT PUMPS WITH 2HN, 2HW, OR 2HK ELECTRIC HEAT KITS WITH NO OUTDOOR THERMOSTAT E1RA SERIES HEAT PUMPS LOW VOLTAGE WIRING - E1RA HEAT PUMPS WITH 2HV ELECTRIC HEAT KIT WITH NO OUTDOOR THERMOSTAT 10 Unitary Products Group

11 TYPICAL FIELD WIRING TG1Y E1RA SERIES HEAT PUMPS LOW VOLTAGE WIRING - E1RA HEAT PUMPS WITH 2HN, 2HW, OR 2HK ELECTRIC HEAT KITS WITH 2TD OD THERMOSTAT ACCESSORY E1RA SERIES HEAT PUMPS LOW VOLTAGE WIRING - E1RA HEAT PUMPS WITH 2HV ELECTRIC HEAT WITH 2TD OD THERMOSTAT ACCESSORY E1RA SERIES HEAT PUMPS LOW VOLTAGE WIRING - E1RA HEAT PUMPS WITH 2TT TRANSFORMER WITH NO ELECTRIC HEAT Unitary Products Group 11

12 MATCHING INDOOR COMPONENTS Add-On Coils - For Furnace Application 5 ➀ UPFLOW G3UA AND G2UT ➁ DOWNFLOW G3CN Air Handlers - For Non-Furnace Application UPFLOW➂ DOWNFLOW HORIZONTAL ➃ ➄ BLOWER N1VS, N2AH, N4AH or N1FA, N3FA G3HC OR G1FC UPFLOW HORIZONTAL ➂ ➄ F1RP OR F1RC FAN ACCESSORIES Refer to Price Manual for specific model numbers. Compressor Blanket - Designed to futher reduce the normal operating sound and is required to meet Canadian sound levels for units of three tons and below. Stub Adapters - Available to adapt sweat connect units to quick connect coils or sweat connect coils to quick connect units. Precharged Line Sets - Available in 15, 25, 35 and 50 foot lengths for connection of sweat models with stub adapters. Outdoor ends have F-6 and F-11 fittings to connect to outdoor units which have M-6 liquid and M-11 vapor fittings. Indoor ends have M-6 and M-11 fittings to connect to indoor coils which have F-6 liquid and F-11 vapor fittings. All indoor vapor ends are provided with a 90 bend. A 30 foot line set with straight ends is available for splicing to other lines for longer runs. All vapor lines are insulated with 1 2 " sponge rubber. Blower Time Delay - 2FD allows blower to run 60 seconds after the cooling thermostat has been satisfied.hard Start Kit (Single Phase Units) - Provides required starting torque for use with thermal expansion valve. Low Temperature Lockout - 2LT Prevents heat pump operation below minus 10 F ambient temperature. Outdoor Thermostat - 2TD Consists of an adjustable outdoor thermostat and relay in a vented enclosure. It provides additional second stage control of the supplemental resistance heat. (balance point control) Room Thermostats - One of the following thermostats may be used with these heat pump systems. 6ET Two stage heat / one stage cool / electronic manual changeover nonprogrammable 6TH Two stage heat / one stage cool / electronic manual changeover. Unitary Products Group P.O. Box 1592, York, Pennsylvania USA Subject to change without notice. Printed in U.S.A. Copyright by York International Corporation All Rights Reserved. Code: EBY, EGY TG1Y Supersedes: TG1Y (1095)

SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS

SPLIT SYSTEM HEAT PUMPS. ERA Series 10 SEER Single and Three Phase TECHNICAL SPECIFICATIONS 515.16-TG1Y (499) TECHNICAL SPECIFICATIONS SPLIT SYSTEM HEAT PUMPS Models 018-060 1Ø 036, 048 3Ø ERA Series 10 SEER Single and Three Phase Models ERA 018 thru ERA090 Nominal Capacity: 18 thru 90 MBH Models

More information

SPLIT SYSTEM HEAT PUMP 12 SEER

SPLIT SYSTEM HEAT PUMP 12 SEER 515.18-TG1C (600) SPLIT SYSTEM HEAT PUMP 12 SEER 018 thru 060 1.5 thru 5 NOMINAL TONS GENERAL DESCRIPTION The series heat pumps are designed for use with a variety of UPG evaporator sections to suit any

More information

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES (1295) STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES - 12.00 SEER S E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION These high efficiency EFH Series heat pump units are the outdoor

More information

TECHNICAL GUIDE DESCRIPTION

TECHNICAL GUIDE DESCRIPTION TECHNICAL GUE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: BRCS018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*BA-(T,W)036 THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) S: 018-060 (1 PH & 3 PH) S: 076-090 (3 PH)

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED P G TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 10 SEER MODELS: HP018X10* THRU 060X10* (1.5 THRU 5 NOMINAL TONS) HP036X10* THRU 060X10* (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management

More information

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS:

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS: 036-21023-002 Rev A (5/00) TECHNICAL GUIDE 16 SEER 2-5 TON CONDITIONING SPLIT-SYSTEM COOLING DESCRIPTION The HTS Stealth series condensing units use Twin Single compressor technology to provide cooling

More information

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) TECHNICAL GUIDE TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE S: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) LISTED Due to continuous product improvement, specifications are subject

More information

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60 TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous

More information

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES TECHNICAL GUIDE RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RHP14J18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE)

TECHNICAL GUIDE LISTED SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE) TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: THGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS - 3 PHASE) LISTED ISO 9001 Certified Quality Management System Due to continuous product improvement,

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED T I I I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER MODELS: H*BA018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*BA036(25,46) THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) This product was manufactured

More information

LISTED TECHNICAL GUIDE STELLAR 2000 TM

LISTED TECHNICAL GUIDE STELLAR 2000 TM E T I I I R P I T I O I N G TECHNICAL GUIDE STELLAR 2000 TM SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: H*DB018 THRU 060 (1 THRU 5 NOMINAL TONS, 1 PH) H*DB036 THRU 076 (3 THRU 6-1/3 NOMINAL TONS, 3 PH) This

More information

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A Single Phase MODELS: YHJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A Single Phase MODELS: YHJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY DESCRIPTION 571209-YTG-B-1211 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

TECHNICAL GUIDE MODELS: RHP13J30 THRU 60 (3 ) RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS. TECHNICAL GUIDE RHP SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS S: RHP13J30 THRU 60 (3 ) Due to continuous product improvement, specifications are subject to change without

More information

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES P G 036-21342-002 Rev. C (0902) TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) U R MA N U F A CT R E C E CE R T I F R T I UN I TA RY A R I F I

More information

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) E T I I I R P I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: AC018X12* THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) LISTED ISO 9001 Certified Quality Management System CERTIFICATION APPLIES

More information

LISTED TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A MODELS: THJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A MODELS: THJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES DESCRIPTION 560550-CTG-A-0310 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED E T I I I R P I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 12 SEER MODELS: H*BC-F018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH)H*BC- (T,W)036 THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001

More information

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC13J18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 S: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) LISTED Due to continuous product improvement, specifications are subject to change without

More information

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES DESCRIPTION 364834-YTG-H-0509 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

LISTED TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A MODELS: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A S: YHJR18-60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) LISTED Due to continuous product improvement, specifications are subject to change without

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A Single Phase MODELS: YHJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY

TECHNICAL GUIDE. SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A Single Phase MODELS: YHJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES WARRANTY DESCRIPTION 561923-YTG-C-1211 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC13J18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS DESCRIPTION

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS DESCRIPTION 571209-YTG-F-0615 DESCRIPTION The 14 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING

STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING (598) STELLAR 2000 SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING HEAT PUMP S: F2RP / F2FP018 THRU 060 COOLING S: F2RC / F2FC018 THRU 036 VARIABLE SPEED : F2FV060 DESCRIPTION This fan coil

More information

TECHNICAL GUIDE MODELS: THJD18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: THJD18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION 571471-LTG-C-1012 The 13 SEER Series unit is the outdoor part of a versatile climate system. It i76s designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

LISTED TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES DESCRIPTION 567175-YTG-C-1010 The 16 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

LISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE)

LISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A MODELS: TCJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A MODELS: TCJF18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES DESCRIPTION 700696-CTG-A-0312 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE MODELS: RAC14J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION

TECHNICAL GUIDE MODELS: RAC14J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION TECHNICAL GUIDE RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: RAC14J18 THRU 60 Due to continuous product improvement, specifications are subject to change

More information

LISTED TECHNICAL GUIDE

LISTED TECHNICAL GUIDE TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS 13 SEER R-22 MODELS: E*RD018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) E*RD030 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) LISTED ISO 9001 Certified Quality Management

More information

TECHNICAL GUIDE MODELS: YHJR18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YHJR18 THRU 60 LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS TECHNICAL GUIDE AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: YZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.     DESCRIPTION TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

LISTED TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS)

LISTED TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS) E T I I I R P I T G 036-21592-002 Rev. A (1204) TECHNICAL GUIDE AFFINITY R-410A SPLIT-SYSTEM AIR CONDITIONERS UP TO 18 SEER MODELS: CZE024 THRU 060 (2 THRU 5 NOMINAL TONS) U R A C T MA N U F R C E UN I

More information

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: YZF024 THRU 060 AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS TECHNICAL GUIDE AFFINITY TM SERIES SPLIT-SYSTEM HEAT PUMPS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: YZF024 THRU 060 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.   DESCRIPTION FEATURE TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806 TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS HEAT PUMP MODELS: F2RP/F2FP018 THRU 060 F3RP/F3FP018 THRU 060(T) FXRP024 THRU 060 COOLING MODELS F2RC/F2FC024 THRU

More information

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: THJD18 THRU 60

Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: THJD18 THRU 60 Technical Guide LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER - R-410A - 1 PHASE 1.5 THRU 5 NOMINAL TONS S: THJD18 THRU 60 Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

TECHNICAL GUIDE MODELS: THJD30 THRU 60 (3 ) LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS.

TECHNICAL GUIDE MODELS: THJD30 THRU 60 (3 ) LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS. TECHNICAL GUIDE LX SERIES SPLIT-SYSTEM HEAT PUMPS 13 SEER R-410A 3 PHASE 2.5 THRU 5 NOMINAL TONS S: THJD30 THRU 60 (3 ) Due to continuous product improvement, specifications are subject to change without

More information

TECHNICAL GUIDE MODELS: TCJD30 THRU 76 LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.3 NOMINAL TONS

TECHNICAL GUIDE MODELS: TCJD30 THRU 76 LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.3 NOMINAL TONS DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES TECHNICAL GUIDE MODELS: N*AH Modular Air Handlers For use w / Split System Cooling & Heat Pump 600-2000 CFM Blowers 2-5 Ton Coils Optional 1 & 3 Electric Heaters DESCRIPTION This unique modular system

More information

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton. AFAIR12B Air Conditioners Features Top discharge directs hot air and noise away from the living area Durable Copeland scroll compressor with internal pressure relief valves and inherent thermal protection

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: YCJF18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES DESCRIPTION 700695-YTG-C-0714 The 14.5 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6. DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

10+ SEER - AIR CONDITIONER

10+ SEER - AIR CONDITIONER 10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

10+ SEER - AIR CONDITIONER

10+ SEER - AIR CONDITIONER 10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum FORM NO. P66-774 Supersedes Form No. P66-765 Rev. 4 Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES earth friendly refrigerant 13 SEER HEAT PUMPS Features Coils constructed with copper tubing

More information

TECHNICAL GUIDE MODELS: AC8B024 THRU 060* ECHELONTM SERIES SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS DESCRIPTION

TECHNICAL GUIDE MODELS: AC8B024 THRU 060* ECHELONTM SERIES SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS DESCRIPTION 1109218-CTG-B-0515 DESCRIPTION The 18 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from. Available for typical applications this

More information

HP19 Bulletin No August 1994 Supersedes November 1993

HP19 Bulletin No August 1994 Supersedes November 1993 ENGINEERING DATA HP19 SERIES HEAT PUMP OUTDOOR UNITS 10.05 to 12.15 SEER *18,000 to 61,000 (5.3 to 17.9 ) *18,800 to 59,000 (5.5 to 17.3 ) *ARI Standard 210/240 certified Ratings HEAT PUMP OUTDOOR UNITS

More information

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6.

TECHNICAL GUIDE MODELS: YCJD30 THRU 76 (3 ) LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE 2.5 THRU 6. DESCRIPTION The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available for typical

More information

TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: TCHD18 THRU 60

TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: TCHD18 THRU 60 TECHNICAL GUIDE HORIZONTAL DISCHARGE SPLIT SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS S: TCHD18 THRU 60 Due to continuous product improvement, specifications are subject to

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES FORM NO. PTZ-781 Supersedes Form No. PTZ-781 Featuring New Industry Standard R-410A Refrigerant TZPL SERIES Manufactured for Thermal Zone Philadelphia, PA (IN CERTAIN MATCHED SYSTEMS) 14.5 SEER HEAT PUMPS

More information

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]

More information

TECHNICAL GUIDE LISTED

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: H*BD-F018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PHASE) H*BD-(T,W)036 THRU 060 (2.5 THRU 5 NOMINAL TONS, 3 PHASE) LISTED Due to continuous

More information

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE (1.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE MODELS: TCJD18 THRU 60 LX SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE (1.5 THRU 5 NOMINAL TONS) DESCRIPTION 840621-LTG-A-0612 The 13 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from Johnson Controls Unitary Products. Available

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS (1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece

More information

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged

More information

TECHNICAL GUIDE MODELS: CZH024 THRU 060* SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS AFFINITYTM SERIES DESCRIPTION

TECHNICAL GUIDE MODELS: CZH024 THRU 060* SPLIT SYSTEM AIR CONDITIONERS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS AFFINITYTM SERIES DESCRIPTION 1109217-YTG-B-0515 DESCRIPTION The 18 SEER Series unit is the outdoor part of a versatile climate system. It is designed with a matching indoor coil component from. Available for typical applications this

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

13 HP x

13 HP x E N G I N E E R I N G D ATA H E A T P U M P O U T D O O R U N I T S 13HPX MERIT Series R-410A Bulletin 210460 December 2009 Supersedes November 2009 SEER up to 14.5 1.5 to 5 Tons Cooling Capacity - 18,000

More information

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHA D SERIES UNITARY AIRCONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CONVERTIBLE SINGLE PACKAGE HEAT PUMP FEATURE SINGLE PACKAGE, 2 THRU 5 TON COOLING Single

More information

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only

More information

Q5RD Series Single Packaged Heat Pump, Single Phase

Q5RD Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The Q5 Series single packaged

More information

HEAT PUMPS UPKB- SERIES. Seven Models

HEAT PUMPS UPKB- SERIES. Seven Models FORM NO. P22-754 REV. 1 Supersedes Form No. P11-729 Rev. 8 HEAT PUMPS UPKB- SERIES Seven Models 10 SEER with efficiencies ranging up to 10.30 SEER in certain matched systems. Nominal Sizes 1 1 /2 to 5

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: CZF024 THRU 060

TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: CZF024 THRU 060 TECHNICAL GUIDE AFFINITY TM SERIES SPLIT SYSTEM AIR CONDITIONERS 16 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: CZF024 THRU 060 Due to continuous product improvement, specifications are subject to change

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz 3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS 14HPX MERIT Series R-410A Bulletin No. 210564 October 2017 Supersedes August 2017 SEER up to 16.00 1.5 to 5 Tons Capacity - 18,000 to 61,000 Btuh Heating

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES: 15SEERSplitHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons Product Data AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS DUCTED HEAT PUMP Sizes 018 To 060 1.5 To 5 Nominal Tons Product Data A08379 INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S Sound S Levels as low as 71 dba Design Features S New aesthetics S Small

More information

HS 29. ELITE SERIES SEER up to to 5 Tons Cooling Capacity 12,000 to 62,500 Btuh Bulletin No October 2004 Supersedes September 2003

HS 29. ELITE SERIES SEER up to to 5 Tons Cooling Capacity 12,000 to 62,500 Btuh Bulletin No October 2004 Supersedes September 2003 ENGINEERING DATA AIR CONDITIONERS HS29 ELITE SERIES SEER up to 12.95 1 to 5 Tons 12,000 to 62,500 Btuh Bulletin No. 210304 October 2004 Supersedes September 2003 Direct Drive Fan Lanced Aluminum Fins Heavy

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACX MERIT Series R-410A Bulletin 210739 November 2017 Supersedes August 2017 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh MODEL NUMBER

More information

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just

More information