1 APPLICATION NOTE: CLOSED LOOP INTEGRATION WITH XANBUS ENABLED SCHNEIDER ELECTRIC CONEXT PRODUCTS 1. Safety Warnings, Cautions and Notes General Warning 1.3 Fire Risk Electric Shock Risk Chemical Risk Do s Do Not s DC Motor Connection Transportation 4 2. Maximum Operating Limits Maximum Battery Operating Limits Recommended Battery Operating Settings 5 3. Installation Battery DC and Communication Connections Installation Battery Location Battery Connection and Parallel Wiring 7 4. Networking Xanbus Network AESbus Network Verify Network Connections Verify Xanbus Connections Verify AEBus Connections 9 5. Configuration Settings Fixed Settings Dynamically Controlled Settings Recommended User-Adjustable Battery Related Settings REV A # Crestwood Place, Richmond, BC, V6V 2E9, Canada info@

2 OVERVIEW There are notable performance and configuration differences when comparing your AES battery installation with that of a conventional lead battery installation. This Application Note provides information about the integration of Discover Xanbus enabled AES batteries with Xanbus enabled Schneider Electric Conext components. Plug and play communications automatically configure the charge and discharge settings of the Inverters and charge controllers. When AES batteries are connected to the Conext system they will automatically configure critical battery related settings and in most cases user configuration is not required. The AES battery provides more accurate battery status readings than the inverter/charger. The AES battery will dynamically control the charge characteristics by using its internal voltage, current, and temperature measurements. This will reduced charging time and provide for intelligent battery balancing. Supported Schneider Electric documents: Schneider Electric Conext XW+ Installation Guide Schneider Electric Conext SW Installation Guide Discover Reference documents: Discover Energy Data Sheet Discover Energy Data Sheet Discover Energy Charge Algorithm Discover Energy Charge Algorithm Discover Energy GEN 2 Product Manual Visit for the most recent version of published documents. Certain configuration, installations, service, and operating tasks should only be performed by qualified personnel in consultation with local utilities and/or authorized dealers. Qualified personnel should have training, knowledge, and experience in: Installing electrical equipment Applying applicable installation codes Analyzing and reducing hazards involved in performing electrical work Installing and configuring batteries No responsibility is assumed by Discover for any consequences arising out of the use of this material. 2

3 1. SAFETY 1.1 Warnings, Cautions, Notes and Symbols WARNING Important information regarding possible personal injury. CAUTION Important information regarding possible equipment damage. NOTE Additional information concerning important procedures and features of the battery. 1.2 General Warning CAUTION It is important to operate the device with care to avoid undesirable consequences. Do not throw in the garbage. Do not dispose in fire. Use personal protective equipment when working with batteries. Additional information concerning important procedures and features of the battery. Read all the instructions before installation, operation and maintenance. This product must be recycled and is made of recycled products. CAUTION Do not disassemble or modify the battery. If the battery housing is damaged, do not touch exposed contents. 1.3 Fire Risk WARNING Risk of fire - No user serviceable parts. Battery has a Battery Management System (BMS) with integrated solid state relay to reduce fire risk. Primary suppression for lithium battery fires is water. Secondary suppression is CO2, powder and halon. 1.4 Electric Shock Risk 1.5 Chemical Risk WARNING For wet and electrically uninsulated working conditions, electric shock risk is high, and can cause injury and death. WARNING Lithium batteries are a chemical risk if misoperated, mishandled or abused. 3 3

4 1.6 Do s Do protect terminals from short circuit before, during, and after installation Do wear electrically insulated gloves Do use electrically insulated tools Do wear eye protection Do wear safety toe boots / shoes Do handle battery carefully Do secure battery safely Do always assume battery terminals are energized 1.7 Do Not s Do not immerse battery in water Do not lift or carry the battery during usage or operation Do not operate or store battery outside of operating limits Do not short circuit battery Do not puncture battery Do not expose battery to flames, or incinerate Do not open battery case or dissemble battery Do not wear rings, watches, bracelets or necklaces when handling or working near battery Do not drop or crush battery Do not lift battery by the terminal cables Do not vibrate battery Do not expose battery to water or other fluids Do not expose battery to direct sunlight Do not dispose of battery Do not connect with other types of batteries Do not expose battery to high temperatures Do not install with other battery types or brands 1.8 DC Motor Connection Without proper safety protection, direct connection to DC motors, motor controllers and external motor voltage clamping systems (such as high power anti-parallel diodes or braking resistor systems) may result in damage to the internal pack protection system which may result in unsafe situations. Please consult Discover technical support before directly connecting any motor loads. 1.9 Transportation If the battery is not installed in equipment, it must be transported in the original package or equivalent. Batteries are tested according to UN Handbook of Tests and Criteria, part III, sub section 38.3 (ST/SG/AC. 10/11/Rev.5). For transport the batteries belong to category UN3480, Class 9, Packaging Group II. 2. MAXIMUM OPERATING LIMITS 2.1 Maximum Battery Operating Limits The battery should not be operated outside these operating limits. The BMS will open its internal relay and disconnect the battery if any of these limits are exceeded. Maximum Operating Limits Continuous Charge Current* 110 Adc 130 Adc Continuous Discharge Current* 110 Adc 130 Adc Charge Voltage 27.2 V 54.4 V Operating Voltage (Min / Max) 22.4 V / 29.2 V 44.8 V / 58.4 V Charge Temperature (Min / Max) Discharge Temperature (Min / Max) Storage Temperature (Min / Max) * Effects of AC Ripple must be taken into consideration when sizing and configuring your system. 0 C / 45 C (32 F / 113 F) -20 C / 50 C (-4 F / 122 F) -20 C / 45 C (-4 F / 113 F) 4

5 NOTE! Intentional bypassing of BMS to operate battery outside maximum and minimum limits voids warranty. 2.2 Recommended Battery Operating Settings Although the battery is capable of performing at higher operating limits, the following settings are recommended to maximize battery health and account for unforeseen external conditions. Recommended Operating Settings Max Continuous Charge Current < 78 A < 92 A Max Continuous Discharge Current < 78 A < 92 A Charge Voltage (Bulk/Absorb) 27.2 V 54.4 V Low Voltage Disconnect 24 V 48 V Operating Temperature 20 C (68 F) 3. INSTALLATION WARNING! Read Safety Section before installing the battery. CAUTION! Do not install batteries in series. Select the appropriate AES battery model for the voltage of your system. 3.1 Battery DC and Communication Connections ITEM 1 DESCRIPTION COM1 AEBus interface to connect to AES enabled devices 2 COM2 Xanbus 3 USB interface for PC connectivity On-Off when battery is enabled blue power light will be illuminated Battery Positive (+) (red) DC terminal connects to the positive bus bar of the DC Switchgear Battery Negative (-) (black) DC terminal connects to the negative bus bar of the DC Switchgear Figure 1. Discover AES terminal deck. 5

6 3.2 Installation Check that battery is switched off If the battery circuit has a disconnect, open the disconnect to isolate battery Clean cable connections. Broken, frayed, brittle, kinked or cut cables should be replaced Install and secure battery. Be careful not to ground the terminals to any metal mounting, fixture, or body part Connect battery cables. Connect ground cable last to avoid sparks Recommended terminal torque is 9.0 Nm (6.64 ft-lb) Washers ARE ARE NOT NOT compressed! Close circuit disconnect (if open) Turn battery switch on Copper compression lug Shrink-wrap to color-code the cable Terminal surface Figure 2. Terminal stack. M8 bolt (supplied with battery) Lock washer (supplied with battery) Flat washer (supplied with battery) Battery cable lug Ensure nothing is between the terminal surface and the battery cable lug Terminal hardware IS bottomed out! Terminal hardware IS bottomed out! Terminal hardware IS NOT bottomed out! Figure 3. Proper hardware selection. Terminal hardware IS NOT bottomed out! NOTE! All cable ends must be connected to battery terminals without any washers between terminal bushings and cable ends. Terminal burnout is caused by: Discharge currents exceeding allowable limits Improper cable installation Improper cable sizing Improper terminal torque NOTE! Without exception, product experiencing terminal burn out will not be warranted. 3.3 Battery Location Locate the batteries close to the inverter in order to minimize the length of the battery cables. However, care should be taken to ensure adequate clearance above the batteries is maintained for access to both battery and inverter connections and disconnects. Battery performance and service life will be optimized when operating in an ambient temperature of 15 C to 25 C (59 F to 77 F). Care should be taken to ensure that the battery s temperature is > 0 C (32 F) during charging. 6

7 3.4 Battery Connection and Parallel Wiring To ensure proper balancing and load sharing between parallel batteries refer to the wiring diagram below. Actual wiring requirements may vary. Consult with your local authority having jurisdiction. LO All parallel cablesall should be cables the same length. parallel should be the same length. Figure 4. Two parallel batteries. / ALTERNATE 1 Figure 5. Three parallel batteries. ALTERNATE 1 ALTERNATE 2 All cables should be the same length. ALTERNATE 1 ALTERNATE 2 All cables should be the same length. All cables should be the same length. Figure 6. Two parallel batteries with DC terminal blocks. Figure 7. Three parallel batteries with DC terminal blocks. 4. NETWORKING NOTE! All cables should be the same length. All cables should be the same length. Connect the battery to the end of the Xanbus network. 4.1 Xanbus Network Xanbus enabled devices communicate with each other over the Xanbus network to share settings, activity and other updates. It is a requirement for one battery from the AES network to be connected to the Xanbus network. No more than one battery may be connect to the Xanbus network. The AES network of batteries will communicate as 'one battery' providing battery bank settings, activity and real time status to the other devices on the Xanbus network. No more than one AES network of batteries may be connected to Xanbus. 7

8 Inverter Solar Charger Controller Battery Conext Combox System Control Panel Network Terminator Network Terminator Xanbus Network Figure 4. Xanbus Network Network Terminators are required for proper functioning of the Xanbus network. Care should be taken to ensure they are installed. CAUTION Only one AES battery is required to be connected to the Xanbus network. Failure to do so could result in impaired system performance. 4.2 AEBus Network The AEBus is utilized by all networked AES batteries to coordinate all voltage, temperature, and current data. Network Terminators are required for proper functioning of the AES network. Care should be taken to ensure they are installed. Figure 5. The AESbus Network connected to Xanbus Network 8

9 4.3 Verify Network Connections Verify Network Connections To verify that all batteries are communicating over Xanbus, please review the following steps. All networked Discover AES Lithium batteries will appear as a single battery, BattMon 00, in the Select Device screen of the Conext System Control Panel (SCP). To view this screen, follow the steps below: SCP: (System Status screen) Enter button (Select Device screen) Once in this screen navigate with the and buttons to locate the BattMon 00 device. If the BattMon 00 is listed, the Discover AES battery connection was successful. If connection is unsuccessful, check that network is correctly terminated and for any damage to the network cabling, terminators and connectors. Confirm all batteries have the same firmware revision. Rectify any problems and verify again Verify AEBus Connection To verify that all batteries are communicating over AEBus follow the steps below: SCP: (System Status Screen) Enter Button (Select Device Screen) and buttons to select (BattMon 00) press Enter/ / buttons at the same time to enable access to (Advanced Settings Menu) If the connection was successful, the listed Capacity should be as follows: Product Capacity 110 Ah x number of batteries 130 Ah x number of batteries If the connection is unsuccessful, check that network is correctly terminated and for any damage to the network cabling, terminators and connectors. Confirm all batteries have the same firmware revision. Rectify any problems and verify again. 5.0 CONFIGURATION SETTINGS 5.1 Fixed Settings The settings in the table below are automatically set by AES batteries when they are connected via Xanbus. These settings will automatically be reset by the AES battery if inadvertently adjusted by the user. Batt Type Settings Custom High Batt Cut Out 29.2V 58.4 V Low Batt Cut Out Hyst 1.8V 3.5 V High Batt Cut Out Hyst 1.2V 2.4 V High Batt Warning 28.8V 57.6 Low Batt Warning 24.8V 49.6 Low Batt Warning Hyst 1V 1.9 V High Batt Warning Hyst 0.8V 1.6 V Float Voltage 26.8V 53.6 V Battery Capacity 48V Determined by number of AES batteries on the AEBus network. Eg. 2x = 260Ah 9

10 NOTE! Fixed settings and dynamically controlled settings are configured by the AES battery. No user configuration is necessary. These settings will automatically be reset by the AES battery if inadvertently adjusted by the user. 5.2 Dynamically Controlled Settings These settings are dynamically Configured by AES Batteries Through Xanbus Network. Bulk Voltage Settings Absorption Voltage Max 28.4V to charge and balance efficiently without causing over voltage fault 48V Max 56.8V to charge and balance efficiently without causing over voltage fault Low Batt Cut Out (LBCO) 24 V 48 V 5.3 Recommended User-Adjustable Battery Related Settings Recommended User-Adjustable Settings for XW+ Inverter/Charger. Settings Grid Supp Volts (GSV) Description Setting GSV below 51.5V will likely cause under voltage protection before LBCO setting. Set above Conext MPPT Solar Charge Controllers equalization voltage for enhanced grid support Nominal System Voltage (48V) 64V ReCharge Volts Setting ReCharge Volts higher allows for more back-up capacity. Setting lower helps maximize self consumption. See Table 15 for further guidance Min 51.5 V Max Chg Rate Limited to maximum battery bank current 1C Charge Cycle 2-Stage Recommended User-Adjustable Settings for the SW Inverter/Charger. Settings Description AC Supp on SoC Enables the SOC monitoring for AC support mode Enabled Enabled AC Supp Start SoC Sets high SOC value required for AC support to engage 80% 80% AC Supp Stop SoC Sets low SoC value for AC support to disengage 20% 20% ReCharge Volts Setting ReCharge Volts Higher allows for more back-up capacity. Setting lower helps maximize self consumption Min 25.8V 48VV Min 51.5 V Max Chg Rate Limited to maximum battery bank current < 1C < 1C Charge Cycle 2-Stage NOTE! User-Adjustable settings are configured by the user. 10

11 Recommended User-Adjustable Settings for Solar Charge Controllers. Settings Description 48VV Max Chg Rate Limited to maximum battery bank current < 1C < 1C Charge Cycle 2-Stage Recommended User-Adjustable Settings for Automatic Generator Start (AGS). AGS Triggers 48V Start DCV 30 sec 25V (LCBO +1V) 49V (LCBO +1V) Stop Absorb Disabled Disabled Start SoC > 10% > 10% Stop SoC < 95% < 95% ReCharge Voltage Setting Guidance Remaining Capacity 48V 10-15%* 24.5V* 49V* 15-20% 25V 50V Battery Voltage (Grid Supp Volts) (RechargeV+0.5V) VBatt Grid Support Mode/Sell Load Shave Mode 20-30% 25.8V 51.5V 40-50% 26V 52V AC Pass-Through 80-90% 26.3V 52.5V % 27V 54V (LBCO)V+1V * Not recommended. Inverter may display Low Batt Warning. Charge Mode LoadShave Start (entry) LoadShave Stop (exit) (A) Figure 6. Grid Support Load Shave Mode. 11

APPLICATION NOTE: OPEN LOOP INTEGRATION WITH MAGNUM ENERGY

APPLICATION NOTE: OPEN LOOP INTEGRATION WITH MAGNUM ENERGY APPLICATION NOTE: OPEN LOOP INTEGRATION WITH MAGNUM ENERGY 1. Safety 3 1.1 Warnings, Cautions and Notes 3 1.2 General Warning 3 1.3 Fire Risk 3 1.4 Electric Shock Risk 3 1.5 Chemical Risk 3 1.6 Do s 4

More information

Operating Manual Crestwood Place, Richmond, BC, V6V 2E9, Canada discoverbattery.com

Operating Manual Crestwood Place, Richmond, BC, V6V 2E9, Canada discoverbattery.com Operating Manual 44-24-2800 42-48-6650 1. Safety 2 1.1 Warnings, Cautions and Notes 2 1.2 General Warning 2 1.3 Fire Risk 2 1.4 Electric Shock Risk 2 1.5 Chemical Risk 3 1.6 Do s 3 1.7 Do Not s 3 1.8 DC

More information

APPLICATION NOTE: XANBUS ENABLED DISCOVER ADVANCED ENERGY SYSTEMS AND SCHNEIDER ELECTRIC CONEXT INTEGRATION DOCUMENT NUMBER

APPLICATION NOTE: XANBUS ENABLED DISCOVER ADVANCED ENERGY SYSTEMS AND SCHNEIDER ELECTRIC CONEXT INTEGRATION DOCUMENT NUMBER APPLICATION NOTE: XANBUS ENABLED DISCOVER ADVANCED ENERGY SYSTEMS AND SCHNEIDER ELECTRIC CONEXT INTEGRATION DOCUMENT NUMBER 885-0001 DOCUMENT REVISION REV C Revision Date Revision Author Description of

More information

Operating Manual / / REV F

Operating Manual / / REV F Operating Manual 14-24-2800 / 44-24-2800 1. Safety 2 1.1 Warnings, Cautions and Notes 2 1.2 General Warning 2 1.3 Fire Risk 2 1.4 Electric Shock Risk 2 1.5 Chemical Risk 3 1.6 Do s 3 1.7 Do Not s 3 1.8

More information

Operating Manual

Operating Manual Operating Manual 15-24-1000 15-36-1000 1. Safety 2 1.1 Warnings, Cautions and Notes 2 1.2 General Warning 2 1.3 Fire Risk 2 1.4 Electric Shock Risk 2 1.5 Chemical Risk 3 1.6 Do s 3 1.7 Do Not s 3 1.8 DC

More information

APPLICATION NOTE: OPEN LOOP INTEGRATION WITH VICTRON ENERGY

APPLICATION NOTE: OPEN LOOP INTEGRATION WITH VICTRON ENERGY APPLICATION NOTE: OPEN LOOP INTEGRATION WITH VICTRON ENERGY 1. Battery Operating Limits 2 1.1 Maximum Battery Operating Limits 2 1.2 Recommended Battery Operating Settings 2 2.0 AES Open Loop Integration

More information

Freedom egen System End-of- Line Functional Checklist

Freedom egen System End-of- Line Functional Checklist U Freedom egen System End-of- Line Functional Checklist 976-0361-01-01 Rev A April 2018 DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This checklist is in addition to, and incorporates

More information

Description Sets the priority for the AC source (AC1 or AC2) for qualification and transfer.

Description Sets the priority for the AC source (AC1 or AC2) for qualification and transfer. AC Settings AC Settings Table 3-5 AC Settings Menu The AC Settings menu configures the voltage and frequency limits for AC port 1 (Grid) and AC port 2 (Gen). These are the limits at which the Xantrex XW

More information

SimpliPhi Power PHI Battery

SimpliPhi Power PHI Battery Power. On Your Terms. SimpliPhi Power PHI Battery INTEGRATION GUIDE: MAGNUM ENERGY Optimized Energy Storage & Management for Residential & Commercial Applications Utilizing Efficient, Safe, Non-Toxic,

More information

Conext SW Inverter/Charger

Conext SW Inverter/Charger Conext SW Inverter/Charger Conext SW 2524 230 (865-2524-61) Conext SW 4024 230 (865-4024-61) Conext SW 4048 230 (865-4048-61) Owner s Guide 975-0636-01-01 Rev E 7-2015 TM solar.schneider-electric.com Conext

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

Conext SW Inverter Charger

Conext SW Inverter Charger Conext SW Inverter Charger Conext SW 2524 120/240 Split-phase (865-2524) Conext SW 4024 120/240 Split-phase (865-4024) Owner s Guide TM www.schneider-electric.com Conext SW Inverter Charger Conext SW

More information

Installation Guide B-BOX Pro2.5 ~ 10.0

Installation Guide B-BOX Pro2.5 ~ 10.0 Installation Guide B-BOX Pro2.5 ~ 10.0 20170625 Version:2.1 1 / 37 Content Safety... 4 1 Product overview... 5 2 Cabinet terminal introduction... 6 3 Cable outlet of cabinet... 7 4 B-Plus2.5 interface

More information

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY SMT WITH MPPT TECHNOLOGY Installation and Operation Manual Model:SMT SMT Dimensions Specification Summary System Voltage 12 V/24V Rated Battery Current 12V, 5A 8A 10A 15A 20A 25A 24V, 5A 8A 10A 15A Rated

More information

Conext XW Inverter/Charger

Conext XW Inverter/Charger Conext XW Inverter/Charger Conext XW+ 7048 E Conext XW+ 8548 E Owner s Guide 975-0713-01-01 Rev D November 2017 http://solar.schneider-electric.com Conext XW Inverter/Charger Owner s Guide http://solar.schneider-electric.com

More information

The Traveler Series TM : Adventurer

The Traveler Series TM : Adventurer The Traveler Series TM : Adventurer 30A PWM Flush Mount Charge Controller w/ LCD Display 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 3.4 Important Safety Instructions Please save

More information

The Traveler Series: Adventurer

The Traveler Series: Adventurer The Traveler Series: Adventurer RENOGY 30A Flush Mount Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.2 Important Safety Instructions Please save these instructions.

More information

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA Appliances 420-00300-02 PC TV Light Electricfan Table Of Contents GENERAL PRECAUTIONS... 1 PERSONNEL PRECAUTIONS... 1 INTRODUCTION...

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A PWM Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version: 2.3 Important Safety Instructions Please save these instructions.

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

DANGER. The Conext products below can utilize Load Shedding and Load Shifting:

DANGER. The Conext products below can utilize Load Shedding and Load Shifting: Conext XW+/XW/SW/MPPT SCC - Load Shedding and Load Shifting to Address Time-of- Use (ToU) Metering and Peak Demand Tariffs solar.schneider-electric.com 976-0322-01-01/A July 2015 Application Note EXCLUSION

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.0 Important Safety Instructions Please save these instructions. This

More information

Eclipse Solar Suitcase

Eclipse Solar Suitcase Eclipse Solar Suitcase Renogy 100W 200W 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.0 Important Safety Instructions Please save these instructions. This manual contains important

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Solar Charge Controller Quick Guide 200W 300W 400W 600W 850W V. 2.2 1. Introduction solar charge controller uses PWM-based DSP controller to keep the batteries regulated and prevent batteries from overcharging

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 4: Alarm point for low battery voltage table Model Alarm point SCC-MPPT-300 10.5 V SCC-MPPT-600 21.0 V Table 5: Charging hour table for reference Battery Capacity To 90% capacity @ 25A charging current

More information

SimpliPhi Power PHI Battery

SimpliPhi Power PHI Battery Power. On Your Terms. SimpliPhi Power PHI Battery INTEGRATION GUIDE: VICTRON Optimized Energy Storage & Management for Residential & Commercial Applications Utilizing Efficient, Safe, Non-Toxic, Energy

More information

Conext XW Inverter/Charger

Conext XW Inverter/Charger Conext XW Inverter/Charger Conext XW+ 7048 E Conext XW+ 8548 E Owner s Guide 975-0713-01-01 Rev B July 2015 solar.schneider-electric.com Conext XW Inverter/Charger Owner s Guide solar.schneider-electric.com

More information

Solar Charge Controller

Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Type Battery Type Code SC-600W MPPT Bulk Voltage Floating Voltage Vented 01 28.6 V 26.4 V Sealed 02 28.6 V 26.8 V Gel 03 28.6 V 27.4 V NiCd 04 28.6

More information

Conext Configuration Tool

Conext Configuration Tool AC1 AC2 Event Equalize kw A Inverting Charging Conext Configuration Tool Version 1.00 Owner s Guide! www.sesolar.com Copyright and Contact Copyright 2012, 2014 Schneider Electric. All Rights Reserved.

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Battery 12V battery system 24V battery system Type Type Code Bulk Floating Bulk Floating Vented 01 14.3 V 13.2 V 28.6 V 26.4 V Sealed 02 14.3 V

More information

How To Set Up SimpliPhi Batteries Using OutBack Chargers

How To Set Up SimpliPhi Batteries Using OutBack Chargers Introduction How To Set Up SimpliPhi Batteries Using OutBack Chargers The main focus of this application note will be on setting up OutBack charging sources for best operational performance for SimpliPhi

More information

Wind & Solar Hybrid Controller User Manuel

Wind & Solar Hybrid Controller User Manuel Wind & Solar Hybrid Controller User Manuel Ver.2.0-201307 Thank you for purchasing our product(s). The manual is provided to people who need to install and operate the controller. Read this manual before

More information

Freedom SW Sine Wave Inverter/Chargers

Freedom SW Sine Wave Inverter/Chargers TM RESET GEN SUPPORT INVERTER ENABLED AC IN FAULT TM FREEDOM SW 3012 CLEAR FAULT INVERTER ENABLE FREEDOM SW 3012 INVERTER ENABLED AC IN FAULT CHARGING WARNING FREEDOM SW 3012 CLEAR FAULT INVERTER RESET

More information

Conext MPPT Solar Charge Controller ( )

Conext MPPT Solar Charge Controller ( ) Conext MPPT 60 150 Solar Charge Controller (865-1030-1) Installation and Owner s Guide 975-0400-01-01 Revision H November 2017 Owner s Manual http://solar.schneider-electric.com Conext MPPT 60 150 Solar

More information

Conext Configuration Tool AI

Conext Configuration Tool AI AC1 AC2 Event Equalize kw A Inverting Charging Conext Configuration Tool AI Version 1.01 Owner s Guide 975-0721-01-01 Revision C 06-2016! http://solar.schneider-electric.com Conext Configuration Tool

More information

SimpliPhi Power PHI Battery

SimpliPhi Power PHI Battery Power. On Your Terms. SimpliPhi Power PHI Battery INTEGRATION GUIDE: SELECTRONIC Optimized Energy Storage & Management for Residential & Commercial Applications Utilizing Efficient, Safe, Non-Toxic, Energy

More information

M Series External Battery Frame. User Guide

M Series External Battery Frame. User Guide M Series External Battery Frame User Guide M 24-065-144 BF-NB M 24-100-144 BF-NB M 24-120-144 BF-NB UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY

More information

Freedom SW 230V Sine Wave Inverter/Chargers

Freedom SW 230V Sine Wave Inverter/Chargers TM RESET GEN SUPPORT INVERTER ENABLED AC IN FAULT TM FREEDOM SW 3524 CLEAR FAULT FREEDOM SW 3524 INVERTER ENABLE INVERTER ENABLED AC IN FAULT CHARGING WARNING FREEDOM SW 3524 CLEAR FAULT INVERTER RESET

More information

BYD Battery-Box LV Installation Guidance

BYD Battery-Box LV Installation Guidance Battery-Box L 3.5/7.0/10.5/14.0 Version1.0 1 / 33 Contents 1 SAFETY... 6 2 PRODUCT OVERVIEW... 7 3 BCU INTRODUCTION... 7 4 DESCRIPTION OF B-PLUS L 3.5 INTERFACE AND TERMINAL... 8 5 PREPARATION... 9 5.1

More information

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller Rover Series Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller 0 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.5 Important Safety Instructions Please save these

More information

Conext SW Inverter Charger

Conext SW Inverter Charger ConextSWEUROInstallationGuide.book Page i Friday, January 31, 2014 3:07 PM Conext SW Inverter Charger Conext SW 2524 230 (865-2524-61) Conext SW 4024 230 (865-4024-61) Installation Guide TM www.schneider-electric.com

More information

Xantrex XW System The NEW Standard

Xantrex XW System The NEW Standard Xantrex XW System The NEW Standard XW System Complete system solution Indoor installations from 4 kw to 18 kw Manageable building blocks for simple, easy, field configuration and installation Clean, integrated

More information

Freedom SW Sine Wave Inverter/Chargers

Freedom SW Sine Wave Inverter/Chargers TM RESET GEN SUPPORT INVERTER ENABLED AC IN FAULT TM FREEDOM SW 3012 CLEAR FAULT FREEDOM SW 3012 INVERTER ENABLE INVERTER ENABLED AC IN FAULT CHARGING WARNING FREEDOM SW 3012 CLEAR FAULT INVERTER RESET

More information

Conext XW Inverter/Charger

Conext XW Inverter/Charger Conext XW Inverter/Charger Conext XW+ 8548 E Conext XW+ 7048 E Installation Guide 975-0714-01-01 Rev E November 2017 http://solar.schneider-electric.com Conext XW Inverter/Charger Installation Guide http://solar.schneider-electric.com

More information

Installation Manual. OptoLoop. MiniBMS. Model Numbers

Installation Manual. OptoLoop. MiniBMS. Model Numbers * Model Numbers GT12V450A-F24 GT12V600A-F24 GT24V300A-F24 GT48V150A-F24 GT51V150A-F24 GT12V600A-F27 GT24V300A-F27 GT48V150A-F27 GT51V150A-F27 *See Table 1 for model number details Installation Manual R5

More information

Conext Battery Monitor

Conext Battery Monitor Conext Battery Monitor Owner s Guide www.sesolar.com Copyright 2014 Schneider Electric. All Rights Reserved. Microsoft and Excel are registered trademarks of Microsoft Corporation in the United States

More information

SimpliPhi AccESS Type I and II

SimpliPhi AccESS Type I and II Power. On Your Terms. SimpliPhi AccESS Type I and II INSTALLATION MANUAL Optimized Energy Storage & Management for Residential & Commercial Applications Utilizing Efficient, Safe, Non-Toxic, Energy Dense

More information

Installation Guide Kratos (B10L)

Installation Guide Kratos (B10L) Installation Guide Kratos (B10L) Rev 1.1_Mar.2017 1/ 37 Content Safety... 3 1 Product Overview... 4 2 Cabinet terminal introduction... 5 3 Cable outlet of cabinet... 6 4 B10L2.5M interface and terminal

More information

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters This application note will explain how to AC couple a Grid Tied Inverter (GTI) to an OutBack inverter. When there is a grid

More information

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A Manual EN Appendix Lynx Ion BMS 400A / 1000A 1. SAFETY INSTRUCTIONS 1.1 In general Please read the documentation supplied with this product first, so that you are familiar with the safety signs en directions

More information

Go Power! Manual. GP-Smart Charger

Go Power! Manual. GP-Smart Charger Go Power! Manual GP-Smart Charger Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Toll Free Tel: 866-247-6527 Toll Free Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. IMPORTANT

More information

CTC Battery, Inc. Lithium Iron Phosphate Battery Specification

CTC Battery, Inc. Lithium Iron Phosphate Battery Specification CTC Battery, Inc. Lithium Iron Phosphate Battery Specification Model: 12.8 V 19.8 Ah 10/25/2012 Rev 01 Robert Tan Copyright 2012 CTC Battery, Inc. All Rights Reserved Copyright 2012 CTC Battery, Inc. All

More information

1000-Watt Energy Center

1000-Watt Energy Center 1000-Watt Energy Center OPERATING INSTRUCTIONS Patent Pending Sierra Wave 1000-Watt Energy Center #9675 The Sierra Wave 1000-Watt Energy Center is a heavy duty and efficient portable power center offering

More information

Lithium Power Supply

Lithium Power Supply Lithium Power Supply User Manual LPS 1200W-60Ah LPS 1500W-100Ah LPS 2500W-100Ah Compact lithium battery based power supply - for easy acces to 230V and 12V energy, everywhere! V1.1 Safety Instructions

More information

Conext XW Inverter/Charger

Conext XW Inverter/Charger Conext XW Inverter/Charger Conext XW+ 6848 NA Conext XW+ 5548 NA Installation Guide 975-0239-01-01 Rev M November 2017 http://solar.schneider-electric.com Conext XW Inverter/Charger Installation Guide

More information

XW XW XW Hybrid Inverter/Charger. Operation Guide. XW Hybrid Inverter/Charger

XW XW XW Hybrid Inverter/Charger. Operation Guide. XW Hybrid Inverter/Charger Hybrid Inverter/Charger XW4024-230-50 XW4548-230-50 XW6048-230-50 Operation Guide XW Hybrid Inverter/Charger XW Hybrid Inverter/Charger Operation Guide About Xantrex Xantrex Technology Inc. (www.xantrex.com),

More information

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17. Inverter / Charger Accessory for Steca Solarix PLI 5000-48 3-Phase / Parallel Kit Installation and operating instructions GB Z01 17.31 Table of Contents About this Manual... 2 Purpose... 2 Scope... 2 Keywords

More information

TROJAN BATTERY COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV = ISO

TROJAN BATTERY COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV = ISO USER S GUIDE CONGRATULATIONS on your purchase from Trojan Battery Company, the manufacturer of the world s most trusted deep-cycle batteries. The battery you purchased was engineered by Trojan to deliver

More information

Duo Battery Charge Controller

Duo Battery Charge Controller Duo Battery Charge Controller RENOGY 10A 20A Pulse Width Modulation Solar Charge Controller Manual 1 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678 Version: 1.2 Important Safety Instructions

More information

Battery Charger Series EASY Charger

Battery Charger Series EASY Charger Battery Charger Series EASY Charger User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimensions rely on information s given by the manufacturer.

More information

Installation Guidance. B-Box Pro2.5~10.0

Installation Guidance. B-Box Pro2.5~10.0 Installation Guidance B-Box Pro2.5~10.0 Rev 2.1_Jul.2017 1/ 38 Content Safety... 4 1 Product Overview... 5 2 Cabinet terminal introduction... 6 3 Cable outlet of cabinet... 7 4 B-Plus2.5 interface and

More information

Freedom SW 3000 Sine Wave Inverter/Charger

Freedom SW 3000 Sine Wave Inverter/Charger 3033614 UL 458 CSA 107.1-01 FREEDOM SW 3000 Model Number FGA Number WARNING: Shock hazard. Do not open. No user serviceable parts. Energized from both AC and DC sources. Disconnect all sources before servicing.

More information

AC CONVERTER / BATTERY CHARGER

AC CONVERTER / BATTERY CHARGER AC CONVERTER / BATTERY CHARGER User s Manual MODEL #: CON120AC12/24VDC Listed to UL 458 and CSA 22.2 NO. 107.1 Standards Contents INTRODUCTION... 3 Important Safety Instructions... 3 1. General Description...

More information

Freedom SW 230V Sine Wave Inverter/Chargers

Freedom SW 230V Sine Wave Inverter/Chargers TM RESET GEN SUPPORT TM Freedom SW 3524-230 shown. CLEAR FAULT INVERTER ENABLE FREEDOM SW 3524 INVERTER ENABLED AC IN FAULT CHARGING WARNING FREEDOM SW 3524 FREEDOM SW 3524 FREEDOM SW 3524 Freedom SW 230V

More information

Sentry Battery Charger. Installation and Operations Manual Section 75

Sentry Battery Charger. Installation and Operations Manual Section 75 Sentry Battery Charger Installation and Operations Manual 00-02-0616 03-03-08 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our

More information

BATTERY SAVER LOW RIPPLE HO

BATTERY SAVER LOW RIPPLE HO INSTRUCTION MANUAL BATTERY SAVER LOW RIPPLE HO LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS MODEL #: 091-195-12 INPUT: 120 Volt, 50/60 Hz, 4.5 Amps RMS OUTPUT: 13.2 Volts DC,

More information

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet SOLAR SMART 12/24V 20Amp MPPT Solar Charge controller with Ethernet Embedded web pages, SNMP support, output port for external Relay board and GSM SMS unit port USER MANUAL PLEASE READ THIS MANUAL CAREFULLY

More information

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking. GV-4 Manual Solar Charge Controller with Maximum Power Point Tracking For models: GV-4-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded http://genasun.com Genasun Inc. 1035 Cambridge st. Suite 16B Cambridge,

More information

LS0512 Solar Charge Controller

LS0512 Solar Charge Controller LandStar LS0512 Solar Charge Controller Nominal system voltage Maximum PV input voltage Nominal charge / discharge current 12VDC 35V 5A Contents 1 Important Safety Information... 1 2 General Information...

More information

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS Introduction ST - II Series POWER SUPPLIES These instructions detail the installation and operation requirements for the ST20-II & ST35-II power supplies. These have been designed for operation in RV s

More information

Battery Charger. Series EASY Charger. User s manual

Battery Charger. Series EASY Charger. User s manual Battery Charger Series EASY Charger User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimensions rely on information s given by the manufacturer.

More information

Xantrex XW System Quick Start Guide to Purchasing

Xantrex XW System Quick Start Guide to Purchasing Xantrex XW System Quick Start Guide to Purchasing 1 XW System Component Overview XW INVERTER/ CHARGER XW6048-120/240-60 p/n: 865-1000 MSRP = $4500 XW4548-120/240-60 p/n: 865-1005 MSRP = $3600 XW-POWER

More information

GV-Boost Manual. 8A Input / W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

GV-Boost Manual. 8A Input / W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking GV-Boost Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GVB-8-Pb-12V: GVB-8-Pb-24V: GVB-8-Pb-36V: GVB-8-Pb-48V: GVB-8-Li-**.*V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded 24V Lead-Acid/AGM/Gel/Sealed/Flooded

More information

INSTALLATION INFORMATION

INSTALLATION INFORMATION INSTALLATION INFORMATION BMS ZE6000i-PCBT.xxxx / ver. 2 Programmable battery management system for Lithium Ion battery cells, for up to 32 round or prismatic cells, 10 to 400Ah NOTE: This installation

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

SCCP PWM Charge Controller/Load Manager Owner s Manual

SCCP PWM Charge Controller/Load Manager Owner s Manual SCCP05-050 PWM Charge Controller/Load Manager Owner s Manual NOTE: Follow instructions in order. Charge batteries at least once a week. Use reducers to connect larger wires disconnect to terminals. battery

More information

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Installation and Operating Instructions. MPPT Solar System Controller ISC3040 Installation and Operating Instructions MPPT Solar System Controller ISC3040 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s

More information

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Lithium Battery Disposal: This product contains a lithium battery. A lithium battery should not be thrown away in the trash. Please dispose of the battery at an authorized disposal or recycle center. Check

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power Issued Date > 2016-02-24 Issued Version > V01 1. General Information This specification defines the performance of rechargeable LiFePO4

More information

MULTI-FUNCTION JUMP STARTER

MULTI-FUNCTION JUMP STARTER MULTI-FUNCTION JUMP STARTER FEATURES 1. Flashlight 2. Jump Start Port 3. LED Power indicator 4. USB Output 5. Power button 6. Charging port 7. Car battery clamp 8. Home charger&car charger 9. Portable

More information

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection MANUAL CONGRATULATIONS on the purchase of your new CTEK charger providing professional battery care. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the

More information

Conext MPPT Solar Charge Controller ( )

Conext MPPT Solar Charge Controller ( ) ! Conext MPPT 80 600 Solar Charge Controller (865-1032) Owner s Guide 975-0560-01-01 Rev F May 2015 solar.schneider-electric.com Conext MPPT 80 600 Solar Charge Controller Owner s Guide solar.schneider-electric.com

More information

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before

More information

EV Power - Battery Control Unit Instructions. 8 Cell 24V

EV Power - Battery Control Unit Instructions. 8 Cell 24V EV Power - Battery Control Unit Instructions. 8 Cell 24V PAGE 1 OF 12 BCU-EVPPAK Features - Simple to install and use, microprocessor control. - Low power requirement, just 15mA when switched on with relay

More information

Operating Manual MP-3739

Operating Manual MP-3739 Operating Manual MP-3739 1 About this manual These operating instructions come with the product and should be kept for the life of the product for proper installation and usage. Read these operating instructions

More information

Guidelines for Battery Electric Vehicles in the Underground

Guidelines for Battery Electric Vehicles in the Underground Guidelines for Battery Electric Vehicles in the Underground Energy Storage Systems Rich Zajkowski Energy Storage Safety & Compliance Eng. GE Transportation Agenda Terminology Let s Design a Battery System

More information

LS0512R Solar Light Controller

LS0512R Solar Light Controller LandStar LS0512R Solar Light Controller Nominal system voltage Maximum PV input voltage Nominal charge / discharge current 12VDC 35V 5A Contents 1 Important Safety Information... 1 2 General Information...

More information

GVB-8 (Boost) Manual

GVB-8 (Boost) Manual www.genasun.com GVB-8 (Boost) Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GVB-8-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded GVB-8-Pb-24V: 24V Lead-Acid/AGM/Gel/Sealed/Flooded

More information

Lithium Power Pack LITHIUM-ION BATTERY SYSTEM. With epro Plus Battery Monitor

Lithium Power Pack LITHIUM-ION BATTERY SYSTEM. With epro Plus Battery Monitor Lithium Power Pack LITHIUM-ION BATTERY SYSTEM With epro Plus Battery Monitor LITHIUM-ION BATTERY SYSTEM After 2 years of research, testing and proving, and a further 5 years of infield sales, Enerdrive

More information

Guardian Battery Charger Series. Installation and Operations Manual Section 75

Guardian Battery Charger Series. Installation and Operations Manual Section 75 Guardian Battery Charger Series Installation and Operations Manual 00-02-0615 02-29-08 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to

More information

BYD Battery-Box HV User Manual Battery-Box H 5.1/6.4/7.7/9.0/10.2/11.5

BYD Battery-Box HV User Manual Battery-Box H 5.1/6.4/7.7/9.0/10.2/11.5 Battery-Box H 5.1/6.4/7.7/9.0/10.2/11.5 Version 5.0 Contents 1 General Information... 2 1.1 Validity... 2 1.2 Application... 2 1.3 Intended Use... 2 1.4 Definition... 2 1.5 Identifying The Product... 3

More information

General Precautions. Personnel Precautions

General Precautions. Personnel Precautions USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only

More information

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-4800 BBS-4800E

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-4800 BBS-4800E AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-4800 BBS-4800E SENS part no: 101312 Document revision: K DCN No. 107455 Date 4/2/18 1840 Industrial Circle Longmont, CO 80501 Fax: (303) 678-7504

More information

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE D2 AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-74-12 INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY 1

More information

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0. 12 Vdc 1500 W 2000 VA Overload >125% 60 s >110% 15 min Efficiency 89% Standby adjustment 0.2% - 2% Rated Power Zero load power 14 W Zero load power (power save mode) 3.5 W 10 A 12 Vdc Max Output current

More information

Installation Guidance. B-BOX Res2.5~10.0

Installation Guidance. B-BOX Res2.5~10.0 B-BOX Residential installation guidance Installation Guidance B-BOX Res2.5~10.0 Rev 1.0_April.2017 1 / 34 Content B-BOX Residential installation guidance Safety... 3 1 Product Overview... 3 2 Cabinet introduction...

More information

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function. User Manual Design Features: 1. PFC function. except BC-1215HT / BC-2407HT 2. LCD remote control. BC-1215HT / BC-2407HT 3. Battery temperature sensor function. 4. Tri-LED color indicator for different

More information

FLEXnet DC Programming & Guidelines

FLEXnet DC Programming & Guidelines FLEXnet DC Programming & Guidelines PURPOSE: This document provides a detailed description of the FLEXnet DC Battery Monitor (FN-DC), its operation, and the best way to use it in different applications.

More information