1 DEFROST CONTROLS PARAGON ERC-2 ELECTRONIC REFRIGERATION CONTROL Real time clock for defrost control Integrated Control - Temperature Control Function - Defrost Control Function Output Relays [4] - Compressor - Defrost - Evaporator fan - Alarm Digital temperature display Keypad programming Two Temperature sensors [supplied] - Terminate defrost cycle - Refrigeration cycle Safe Mode Operation - Continues operation based on performance average in the event sensor fails Power Failure Recovery - All settings retained in memory - Time-of-day carried over for 100 hours NSF certified C-UR-us recognized component Rating equivalent to UL and CSA Voltage input 120/208/240VAC, 50 or 60 cycles P4396 P/N ERC ERC DESCRIPTION ERC-2 With NEMA 1 Case and Integrated Display ERC-2 With NEMA 1 Case and Remote Display 1090

2 DEFROST CONTROLS PARAGON COMMERCIAL DEFROST CONTROLS Special Features Time Initiated, Temperature or Pressure Terminated High amp switch contacts, 40 amps, 2 hp Positive slider bar switch designed, assures positive electrical contact and wipes the contact surface of contaminates Designed for defrost termination using an external temperature or pressure device Safety back-up mechanical time driven defrost termination Heavy duty synchronous design drive motor Choice of three contact arrangements Frequency of defrost initiation is adjustable from 1 to 6 cycles per day with a minimum of 4 hours between successive operations Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments Enclosed is constructed of heavy-duty steel with knockouts on the bottom, back and sides. Hasp and staple for padlock is part of the enclosure Models Time Initiated, Time Terminated High amp switch contacts, 40 amps, 2 hp Positive slider bar switch designed, assures positive electrical contact and wipes the contact surface of contaminates Choice of three contact arrangements Heavy duty synchronous design drive motor Frequency of defrost initiation is adjustable from 1 to 6 cycles per day with a minimum of 4 hours between successive operations Duration of the defrost cycle is adjustable from 4 to 110 minutes in 2 minute increments Accuracy of defrost duration is +/ - 2 minutes Enclosed is constructed of heavy-duty steel with knockouts on the bottom, back and sides. Hasp and staple for padlock is part of the enclosure Applications Defrost controls for commercial freezers and refrigerators P1170 P/N 120 VAC 208/240 VAC Time Initiated, Time Terminated Time Initiated, Temperature or Pressure Terminated

3 TIMERS PARAGON ELECTRONIC TIME CONTROLS P1178 P1179 EC4000 EC1015 EC11 & EC11D EC7000 EC7005PC EC71 & EC71D EC4000 SERIES 24-HOUR OR 7-DAY The EC4000 Series are 24-hour, single-channel, electronic time controls that provide simple, inexpensive control of electrical loads with a time-of-day schedule. As a 24-hr. control, the same ON/OFF schedule is utilized each day. Saturday and/or Sunday, or any other day(s) of the week may be skipped. The skipped day(s) can be either load ON all day or load OFF all day, depending upon application. Sixteen events are available to provide programming versatility. An event defines an activity either load ON or load OFF. The EC4000 Series are available in either a NEMA 1 steel enclosure or a NEMA Type 3R non-metallic enclosure for indoor or outdoor use. 24-hr. programming with skip-a-day. Four-day min. power outage carry-over without the use of a battery. 20 amp ballast switch rating on DPST model (UL only). 16 ON or OFFs per day. SPST, SPDT and DPST switching. NEMA 1 or NEMA Type 3R enclosure. Large display & simple programming with just 4 keys. P1180 P1181 RATING PER POLE OF OUTPUT P1182 ENCLOSURE NEMA P1183 SHIPPING WGT. Lb Kg EC4000 Series - 24-hour, single-channel, capacitor carry-over EC4000/120V 20A SPDT EC4000PC/120V 20A SPDT 3R 2-1/2 1.1 EC4000PC/120V-RT 20A SPDT 3R 2-1/2 1.1 EC4000/ V 20A SPDT EC4000PC/ V PC/240V 30A SPDT 3R 2-1/2 1.1 EC4004/120V 30A SPST EC4004/120V-RT 30A SPST EC4004PC/120V 30A SPST 3R 2-1/2 1.1 EC4004PC/120V-RT 30A SPST 3R 2-1/2 1.1 EC4004/ V 30A SPST EC4004/ V-RT 30A SPST EC4004PC/ V 30A SPST 3R 2-1/2 1.1 EC4004PC/ V-RT 30A SPST 3R 2-1/2 1.1 EC4005PC/120, V 30A DPST 3R 2-1/2 1.1 EC4005PC/120, V-RT 30A DPST 3R 2-1/2 1.1 EC7000 SERIES 24-HOUR OR 7-DAY EC7000 Series are single-channel, electronic time controls that provide simple, inexpensive control of electrical loads with a time-of-day schedule. When schedules vary from day to day, the 7-day programming capability allows a different schedule for each day of the week. With 16 set points available, the EC7000 Series provides programming versatility. Models are also available to provide two individually programmable durations of one to 59 seconds in addition to the maintained ON & OFF set points. This provides ideal control for bell or chime ringing in schools & factories. The EC7000 Series Controls are ideal for indoor & outdoor lighting, billboard & security lighting, school crossing lights, heating, ventilating, bell, chime & buzzer ringing, water heater & security system control. 24-hr. or 7-day programming - 7-day programming allows greater flexibility thus added energy savings by allowing loads to remain on only when needed. 4-day min. power outage carry-over without the use of batteries. Eliminates the need to replace batteries & the environmental concerns of battery disposal 16 set points 30 amp heavy duty relay-output allows switching most electrical loads without the use of contractors. To-the-minute programming with just four keys & a large easy to read display that uses visual prompts for ease of programming. SPST, SPDT, DPST switching designed for high immunity to electrical noise Momentary feature available. Recessed reset button Available in NEMA Type 3R (EC7005) or NEMA 1 enclosures. NOTE: Also available in 50 amp. Contact your nearest branch for details and other available models. RATING PER POLE OF OUTPUT ENCLOSURE NEMA SHIPPING WGT. Lb Kg EC7000 Series - 24-hour and 7-day, single-channel, capacitor carry-over EC7000/24V 20A SPDT EC7000/120V 20A SPDT EC7000PC/120V-RT 20A SPDT 3R EC7000/ V 20A SPDT EC7001PC/12VDC 10A SPDT 3R 1-1/2 0.7 EC7001/24V 20A SPDT EC7001/120V 20A SPDT EC7001/ V 20A SPDT EC7004/120V 30A SPST EC7004/ V 30A SPST EC7005PC/120V, V 30A DPST 3R EC7005PC/277V 30A DPST 3R EC71/18S Series day, single channel EC71/18S/120V 15A SPDT EC71D/18S/24V 15A SPDT DIN 1-1/8 0.5 EC71D/18S/120V 15A SPDT DIN 1-1/8 0.5 EC71D/18S/240V 10A SPDT DIN 1-1/

4 PARAGON 24-HOUR TIME SWITCHES 4000 & 4000S SERIES 24-HOUR The 4000 series has a 24-hour dial with 2 to 14 replaceable trippers for 1 to 7 On and Off operations per day. The 4000-S series is the same as the 4000 series but with Skip-A-Day feature to allow skipping operations on any day or days of the week without disturbing the preset schedule. 1/2 hour min. On or Off time; 22-1/2 hour max. On or Off time. Manual On/Off lever transfers switch operation without disturbing preset schedule. Switch slider bar assures positive switching. Heavy duty terminals accommodate up to AWG #8 wire. NEMA type 1 indoor case with combination 1/2-3/4 in. knockouts in bottom and sides; hasp for padlock or seal SERIES 4010 SERIES P1203 P1204 TIMERS 4000, 4010 AND 4210 SERIES 1-1/2 Hour Minimum On or Off Time, 1 to 7 On/Off Operations Per Day ENCLOSURE SHIPPING SWITCH HP AC LINE WGT. VOLTS NEMA Lb Kg Series - Standard NEMA 1 indoor metal enclosure SPST / RT SPST / B SPST / M SPST / SPST / B SPST / DPST / RT DPST / M DPST / DPST / RT DPST / B DPST / M DPST / B SPDT /2 1.1 With skip-a-day, allows schedule to be omitted on any day(s) without permanently disturbing preset schedule S DPST / SB DPST / SM DPST / S DPST / S DPST / S SPDT / SB SPDT / S SPDT / S SPDT / SB SPDT With skip-a-day and astro dial, adjusts for seasonal changes in sunrise and sunset times SZ32 DPST SZ42 DPST SZ32 DPST SZ42 DPST SZ32 SPDT SZ42 SPDT SZ32 SPDT SZ42 SPDT Leaves load on during day(s) scheduled to be skipped S DPST / Series - Standard NEMA 3 indoor/outdoor metal or NEMA type 3R plastic enclosure SPST / P SPST R 1-3/ PC-RT SPST R 1-3/ DPST / P DPST R 1-3/ PC-RT DPST R 1-3/ DPST / P DPST 2 208/277 3R 1-3/ PC-RT DPST 2 208/277 3R 1-3/8 0.6 With skip-a-day, allows schedule to be omitted on any day(s) without permanently disturbing preset schedule S DPST / S DPST /4 2.2 With skip-a-day and astro dial, adjusts for seasonal changes in sunrise and sunset times SZ32 DPST / SZ42 DPST /2 2.5 P SERIES 1093

5 TIMERS PARAGON 7-DAY TIME SWITCHES 7000 SERIES 7-day calendar permits different On/Off schedules on different days of the week. Maximum of 4 On/Off operations per day and 28 per week. 3 hour min. On or Off time per day; 21 hour max. On or Off time per day. Independent 4-pole design allows for SPST, DPST or SPDT switching. Manual overrride lever temporarily reverses switch operation without permanently disturbing preset schedule. Switch slider bar assures positive switching Heavy duty industrial type synchronous motor. Heavy duty terminals accommodate up to AWG #8 wire. Standard NEMA 1 indoor metal enclosure side hinged with combination 1/2-3/4 in. knockouts in bottom and side. Hasp for padlock or seal SERIES 7-day calendar permits different On/Off schedules on different days of the week. Maximum of 4 On/Off operations per day and 28 per week. 3 hour min. On or Off time per day; 21 hour max. On or Off time per day. Independent 4-pole design allows for SPST, DPST or SPDT switching. Manual overrride lever temporarily reverses switch operation without permanently disturbing preset schedule. Switch slider bar assures positive switching Heavy duty industrial type synchronous motor. Heavy duty terminals accommodate up to AWG #8 wire. Standard NEMA 3 indoor/outdoor metal enclosure side hinged with combination 1/2-3/4 in. knockouts in bottom and sides. Hasp for padlock or seal. Spring wound carry-over to take over during power outages, keeping control running up to 10 hours. Only two hour wind up required for each hour of power outage and 7210 SERIES 4-Pole, 3 Hour Minimum On or Off Time, 4 On/Off Operations per Day, 28 per Week P1177 AC LINE ENC. SWITCH SWITCH RATING PER POLE SHIPPING WGT. 60 HZ AMP AMP T VA HP VOLTS NEMA Lb Kg 7000 Series PST-4 NO /2 2.9 * PST-4 NO / PST-4 NO / NO-2 NC / B 2 NO-2 NC /2 2.9 * NO-2 NC / NO-2 NC / Series - With spring wound carry-over PST-4 NO PST-4 NO *Not UL or CSA listed. Hp rating one pole only. Furnished with 7 sets of on/off trippers. Switch rating per pole = 40 amp. Hertz =

6 REFRIGERATION DEFROST CONTROLS PARAGON COMMERCIAL REFRIGERATION DEFROST CONTROLS 8040 SERIES Frequency of defrost initiation is adjustable from 1-6 cycles per day. Min of 4 hours between successive operations. Duration of defrost cycle is adjustable from minutes in 2 minute increments. Accuracy of defrost duration ± 2 minutes. Choice of 4 contact arrangements for electric heat, hot gas or compressor shutdown defrost. Positive switch action slider bar. Heavy duty synchronous motor. Heavy steel enclosure. Grey finish. Knockouts on bottom, back and sides. Hasp and staple for padlock. Available on bracket for sub-panel mounting SERIES Frequency of defrost is 1-6 cycles per day. Min of 4 hours between successive defrost cycles. Adjustable back-up defrost termination from minutes in 2 minute increments. Control works with an external temperature or pressure sensor. Choice of 3 contact arrangements for electric heat, compressor shutdown defrost or hot gas defrost. Positive switch action slider bar. Heavy duty synchronous industrial type motor. Heavy steel enclosure. Grey finish. Knockouts on bottom, back and sides. Hasp and staple for padlock. Available on bracket for sub-panel mounting SERIES Time Initiated, Time Terminated, 40 Amp P & 8140 SERIES AC LINE SWITCH ARRANGEMENT ADJ. LENGTH 60 HZ CONTACTS OF DEFROST VOLTS N Closed Open Closed Min Closed Open Closed Min Closed Open None Min Closed Open None Min Open Open Closed Min Open Open Closed Min. NEMA 1 indoor metal enclosure SERIES Time Initiated, Remote Temperature or Pressure Terminated, 40 Amp NORMAL POSITION OF CONTACTS AC LINE DURING REFRIGERATION CYCLE 60 HZ CONTACT CONTACT CONTACT VOLTS N NEMA 1 indoor metal enclosure Closed Open Closed Closed Open Closed Open Closed Open Open Closed Open None Open Closed None Open Closed NEMA 1 indoor metal enclosure. 1095

7 REFRIGERATION DEFROST CONTROLS PARAGON COMMERCIAL REFRIGERATION DEFROST CONTROLS 8240 SERIES Frequency of defrost is 1-6 cycles per day. Min. of 4 hours between successive defrost cycles. Adjustable back-up defrost termination from minutes in 2 minute increments. Choice of 3 contact arrangements for electric heat, compressor shutdown defrost or hot gas defrost. Positive switch action slider bar. Heavy duty synchronous industrial type motor. Heavy steel enclosure. Grey finish. Knockouts on top. Available on bracket for sub-panel mounting. P SERIES 8240 SERIES Time Initiated, Pressure Terminated, 40 Amp NORMAL POSITION OF CONTACTS AC LINE UPC NO. DURING REFRIGERATION CYCLE 60 HZ CONTACT CONTACT CONTACT VOLTS N Closed Open None Closed Open None Open Open Closed NEMA 1 indoor metal enclosure. 1096

8 REFRIGERATION DEFROST CONTROLS/ACCESSORIES PARAGON ACCESSORIES DIAL TRIPPERS, PINS AND BATTERIES PART NUMBER USE WITH SERIES QUANTITY PER SET X ON,1OFF X S 4210-S S 4000-SZ 4210-SZ SZ 6 cutout pins X þ 8140* 8040* 8240* 5 trippers X S S 4210-S S Cutout index tripper (ON) X ON, 1 OFF X7248 RM* 12 X S 1 ON, 1 OFF X9242 P100 1 ON, 1 OFF X9246 P100-S Cutout pins (6) X S Cutout Index tripper (OFF) X9250 P100-S Cutout Index tripper (ON) *See Bulletin #3010. P1184 P1185 P1186 P1187 P1188 P1189 P1190 P1191 X2772 X3495 X3596 X4296 X4299 X8348 X9242 X9246 X9249 X9250 Brackets For Panel Mounting PART SHIPPING WGT. USE WITH SERIES NOTES NUMBER LB KG A454-W (X2626) /2 0.7 A536 (X4105) A537-W (X3967) A569 (X5815) D Intermatic Adapter Bracket A * *Must be used with 4010PC S 4000-SZ S 4010-SZ EC4000 P100 EC7000 not for carry-over models 1-1/ TS 1015 not for carry-over models 1-1/ may be used with carry-over models 1-1/ S EC S P100 EC7000 not for carry-over models 3 oz EC PC EC7001 EC4004 EC7000 EC oz. 0.1 P1192 P1193 P1194 P1195 P1196 P1197 A454 (X2626) A569 (X5815) A536 (X4105) D A537 (X3967) A

24HR 30A SPST TM SW. Features. Long Description

24HR 30A SPST TM SW. Features. Long Description 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ET05C 24HR 30A SPST TM SW Intermatic Inc. Catalog Number Manufacturer Description Weight per unit Product Category ET05C

More information

ET Basic+ Series Electronic Controls

ET Basic+ Series Electronic Controls ET Basic+ Series Electronic Controls Better Control at a Better Price. Intermatic s Basic+ Series meets the demands of today s facilities with precise control, scheduling flexibility, simple installation,

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Part # Features & Applications Specifications Cross Reference

Part # Features & Applications Specifications Cross Reference Solid State Controls 24-ICM450 24-ICM400 Fully Programmable - with LCD diagnostic display. Easy to configure - simple 7-step push-button setup. Easy to customize - set points, variables and features are

More information

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction 7000 series Industrial Electropneumatic Timing Relay File E15631 File LR29186 Note:7032 types and certain models with accessories are not agency approved. Users should thoroughly review the technical data

More information

A25 Series Warm Air Control with Manual Reset

A25 Series Warm Air Control with Manual Reset FANs 125, 121 Product/Technical Bulletin A25 Issue Date 0316 A25 Series Warm Air Control with Manual Reset The A25 Series Warm Air Control with Manual Reset is designed to shut down fans, burners, dampers,

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Special Specification 6058 Battery Back-Up System for Signal Cabinets Special Specification Battery Back-Up System for Signal Cabinets 1. DESCRIPTION 2. DEFINITIONS Install a Battery Back-Up System (BBU System) for traffic signals that will provide reliable emergency power

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC) SWITCH SELECTION GUIDE Toggle Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive @ 115VAC, 28VDC) T1 2 or 3 Position, Momentary, 8A MIL-PRF-83731 15/32" or 1/4" dia.

More information

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT) 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

TOTALINE PROTECTION CONTROLS

TOTALINE PROTECTION CONTROLS TOTALINE PROTECTION CONTROLS SOLID STATE HEAD PRESSURE CONTROL WITH OPTIONAL HEAT PUMP OVERRIDE Head Pressure Controls Temperature sensitive fan motor control which regulates head pressure at low ambients

More information

AccuPower AQU128B Installation Instructions

AccuPower AQU128B Installation Instructions Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU128B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS 1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM

More information

Heat Tracing Sales Mt. Airy, Maryland Controls

Heat Tracing Sales Mt. Airy, Maryland Controls Heat Tracing Line Sensing Control Panels Solid State Relay Output Rated 30 Amps or Two-Pole Contactor Control Output Universal Inputs NEMA 4/4X Enclosure Ground Fault Alarm/Trip Monitor or GFI Circuit

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

60T Series Snap-Action Temperature Controls

60T Series Snap-Action Temperature Controls Series SnapAction Temperature Controls SnapAction Temperature Control The line of 3/4 (19mm) bimetal disc temperature controls from ThermODisc offers proven reliability in a versatile, costeffective design.

More information

Locking-Type Mounting, Thermal Type K4500 Series

Locking-Type Mounting, Thermal Type K4500 Series Locking-Type Mounting, Thermal Type K4500 Series Easy to install; just plug in and twist. This series is equipped with standard 3-prong NEMA locking-type plug connections. Incorporates K4000 style thermal

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS

More information

Digital Time Switches

Digital Time Switches Digital Time Switches Precise time programming for Daily/Weekly/Pulse switching 25 ON/OFF programs Weekend Exclusion (FRI SAT or SAT SUN) and Weekly OFF programming LED Indication of Relay status & 12/24

More information

Central Battery Systems Loadstar AC/DC Systems

Central Battery Systems Loadstar AC/DC Systems The Loadstar range of AC/DC central battery units comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources of emergency power for escape

More information

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up Master atalog 125 s and ontactors Section R Product Bulletin R1000 Issue Date 0493 R1000 Series s The R1000 Series s switch line voltage devices from low voltage controllers. Plug-in DPDT relays and snap-in

More information

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches MiG2 TIME SWITCHES 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches The MiG2 series of timers are programmable 365-day time-switches, incorporating: Multiple switching times per day Single and block

More information

VIBRATION SELECTION GUIDE

VIBRATION SELECTION GUIDE INDUSTRIAL PRODUCTS DIVISION VIBRATION SELECTION GUIDE Industrial Products Division Robertshaw Industrial Products Division 1602 Mustang Drive Maryville, TN 37801 Telephone: (865) 981-3100 Fax: (865) 981-3168

More information

B BASIC HEAT TREATMENT CONSOLE

B BASIC HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

A22NK. Key-type Selector Switches

A22NK. Key-type Selector Switches Key-type Selector Switches -mm dia. Key-type Selector Switches Control panel miniaturization through a more compact design and modified wiring direction. Addition of Push-In Plus terminal blocks for easy

More information

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps 5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps The 5 series is a 2 coil mechanical latch electrical reset power relay. It is panel mounted with screw terminals, and has 600 volt spacing. The 5 series

More information

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

Surface mounting, flush mounting, and DIN track mounting

Surface mounting, flush mounting, and DIN track mounting Solid-state Timer H3JA Economical, Compact, Plug-in Timer Time limit, ON-delay, operation with automatic resetting. DIN size (36 x 36 mm), fits standard 8-pin sockets. Wide choice of supply voltages: 24,

More information

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com

More information

AccuPower AQU126B Installation Instructions

AccuPower AQU126B Installation Instructions Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU126B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead

More information

TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE

TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS P 2 9 1 - RUN CAPACITOR SINGLE P238 MFD PART NUMBER SIGNIFICANCE MFD NON-PCB DIELECTRIC FLUID UL APPROVED CURRENT INTERRUPTER MULTIPLE ELECTRICAL

More information

Remote Temperature Controllers. Quick Selection Guide

Remote Temperature Controllers. Quick Selection Guide Remote Temperature Controllers Quick Selection Guide A Complete Selection For A Wide Range Of Applications Electronic Standalone Controllers T775 Provide on/off, modulating, or reset control in applications

More information

SPECIFICATION BULLETIN

SPECIFICATION BULLETIN SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS on page 3. SPECIAL TO THIS PRODUCT:

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

24-hour/Weekly Time Switch H2F

24-hour/Weekly Time Switch H2F 24-hour/Weekly Time Switch H2F Up to 96 ON/OFF Cycles from DIN-sized (72 x 72 mm) Timer Easy setting with color-coded programming tabs. Choose from 24-hour or 1-week models with either SPST-NO or SPDT

More information

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

General Purpose Buck - Boost Wiring Diagrams... 86

General Purpose Buck - Boost Wiring Diagrams... 86 SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS Security Door Controls & Door Controllers 5 SDC Access Control Power Supplies have been developed specifically to support access controls and electric locking hardware with clean, consistent power. Combined

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller LC-ZEC200-xxxx Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller Description The CCS Variable Air Volume (VAV) Zone Pressure Independent Damper Controllers

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

HUNTERSVILLE, NORTH CAROLINA USA. MAY Fax: Phone toll free:

HUNTERSVILLE, NORTH CAROLINA USA. MAY Fax: Phone toll free: HUNTERSVILLE, NORTH CAROLINA USA E f f ective S e p te m b er 1, 2 0 0 4 www.nsiindustries.com MAY 2009 E-mail: nsi@nsiindustries.com Fax: 800.841.5566 Phone toll free: 1.800.321.5847 MECHANICAL TIME SWITCH

More information

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O Diaphragm Type Differential Pressure Gauge & Switch BULLETIN NO. 130/11 (SUPERSEDES BULLETIN NO. 130/02) is a rugged general purpose differential pressure gauge with a 4-1/2" round dial. Common Applications:

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9

More information

40 Amp Resistive, VAC 40 Amp Tungsten, Inductive or 1000 VA Pilot Duty, VAC 2 HP (24 FLA) 120 VAC 5 HP (28 FLA) 240 VAC single-phase

40 Amp Resistive, VAC 40 Amp Tungsten, Inductive or 1000 VA Pilot Duty, VAC 2 HP (24 FLA) 120 VAC 5 HP (28 FLA) 240 VAC single-phase T100 Series Electromechanical Time Switches T100 Series The T100 Series Mechanical Time Switches are heavy-duty switches that have the highest horsepower ratings in the industry for industrial, commercial

More information

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start) AQUASTAR C6 (Comfort 6000) Next Generation Auto Backwash Valve System (selectable time-pressure or remote cycle start) SIDE MOUNTED AND TOP MOUNTED VALVES WITH QUICK INSTALL ELECTRIC ACTUATORS FOR PIPE

More information

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 TM Table of Contents Table of Contents SELECTION GUIDE PUMPTROL COMMERCIAL PRESSURE SWITCHES...

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Class 9038 Type A Mechanical Alternator, Open Tank

Class 9038 Type A Mechanical Alternator, Open Tank Selection Guide Float Switches Class 9038 Type A Mechanical Alternator, Open Tank Type of Installation Product Features Horsepower rated 4-pole switch Standard action contacts close on liquid rise Reverse

More information

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1 Motor Timer H2A Miniature, High-performance Motor Timer Employs high-reliability bifurcated contacts for output. Moving pointer provided in all types for confirmation of elapsed time. Employs time-out

More information

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21) EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies SDU Series, Direct Current Uninterruptible Power Supply (DC UPS) System The SDU DIN Rail DC UPS is an advanced uninterruptible power system that combines an industry leading design with a wide operational

More information

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz c February, 1979 Supersedes DB 39-485, pages 1-4, dated November, 1973 Mailed to: E, D, C/2001, 2002/DB Benefits There are many capacitor applications in which factors such as physical location, personnel

More information

table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3

table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3 table of contents Switches Quick Guide to Switches....................................... J2-J3 Push Switches.............................................. J4-J7 Single Pole ON-OFF.......................................

More information

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com.11 Product Description Features Special Purpose (Type F), Rotating Shaft (Type J),

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

LOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller

LOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller 505 Series Low voltage DC, regulated, filtered. Step down transformer, fused primary and 6 heavy duty 505 shown with SBP2 KLC screw terminals. 12 VDC - 1 Amp, 24 VDC - 1 Amp, field selectable. Battery

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit:   Mid-West Instrument PISTON STYLE GAUGE For Installation and Operation Manuals Please Visit: www.midwestinstrument.com/literature Mid-West Instrument BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument

More information

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007 Instruction Sheet PA-00281 October 2007 PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls THE FLEXIBLE

More information

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS REMOTE LOCATIONS COMMERCIAL VEHICLES RV/MARINE BACKUP POWER Do you need reliable AC power in a vehicle, remote location or for emergency backup?

More information

Series A DC Link Chokes

Series A DC Link Chokes Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 INTRODUCTION...3 LIST PRICE / CROSS REFERENCE...4 SELECTION & LIST PRICE...5 208 VOLTS (60 HZ)...5 240 VOLTS (60 HZ)...6 400 VOLTS

More information

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect

More information

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures A419 Issue Date February 10, 2003 A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures The A419 series controls are single-stage, electronic temperature

More information

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS) BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS) Programmable Automatic Transfer Switch Operation Manual Main Switch Rated Current 2P/3P/4P 250Amp 2P 400 Amp Main Switch Rated Voltage 690 Vac Taiwan Patent Number

More information

AquaMatic Series. A100 and A200 Stager Controls

AquaMatic Series. A100 and A200 Stager Controls AquaMatic Series A100 and A200 Stager Controls 2 Table of Contents Introduction To AquaMatic Series A100 and A200 Stager Controls3 Specifications 4 Applications 5 Features 6 Cycle Time Programming 7 Setting

More information

IEC Limit Switches Selection Guide

IEC Limit Switches Selection Guide IEC Limit Switches Selection Guide Limit Switches Selection Guide ABM Series ABP Series AAP Series Series ABM Series ABP Series AAP Series Prices start at Description Heavy duty IEC Double-insulated,

More information

JARD by MARS JARD by MARS

JARD by MARS JARD by MARS Table of Contents Description Page No. Capacitors Motor Run....................................................................................... J-3 J-5 Motor Start...........................................................................................J-6

More information

MERCURY CONTACTORS & RELAYS

MERCURY CONTACTORS & RELAYS MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND

More information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay Creepage distance of 8.0 mm (0.31 in) min. between coil and contact Dual-winding latching type available Plug-in and quick-connect terminals available High sensitivity (360 mw) and high

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

TE-6300 Series Temperature Sensors

TE-6300 Series Temperature Sensors TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued July 14, 2008 Supersedes November 13, 2006 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety

More information

PISTON STYLE GAUGE. Mid-West Instrument

PISTON STYLE GAUGE. Mid-West Instrument PISTON STYLE GAUGE Mid-West Instrument 1 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 A low cost differential

More information

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910 s DP, DPA, and SYD Class 89 Compact Design Industry Standard Mounting Double Brea Contacts Low Coil VA Straight-Through Wiring Low Cost Definite purpose contactors are ideal for heating, air conditioning,

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel RCS000 Series Controllable Circuit Breaker Panel RCS000 Data Sheet Overview The RCS000 Series Controllable Circuit Breaker Panels combines the benefi ts of traditional relay based load control and the

More information

Climate Control Products

Climate Control Products Products Filter Fans NEMA 1 Box Fan High airflow with low noise operations makes these versatile packaged fans very popular in a wide range of applications. Reversible mounting brackets allow user to push

More information

IEC Limit Switches Selection Guide

IEC Limit Switches Selection Guide IEC Limit Switches Selection Guide Limit Switches Selection Guide ABM Series ABP Series AAP Series Series ABM Series ABP Series AAP Series Prices start at Description Heavy duty IEC Double-insulated,

More information

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input) Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai- Ph: + Fax: E-mail: info@intechchennai.com Website: www.intechchennai.com Temperature Controllers ECS CSM_ECS_DS_E Simple Functi ons in

More information