AAFAME Presentation. Shermco Industries Inc. Drives and Automation Application, Sales and Service Manager, Irving Texas.

Size: px
Start display at page:

Download "AAFAME Presentation. Shermco Industries Inc. Drives and Automation Application, Sales and Service Manager, Irving Texas."

Transcription

1 AAFAME Presentation Scott D.Holdridge Shermco Industries Inc. Drives and Automation Application, Sales and Service Manager, Irving Texas. 1

2 What we are going to cover in this Presentation Motor Efficiency-NEMA Definitions Applying VFD to NEMA Motors Saving Money- Motors/Drives Fiscal Payback- Infinity Laws 10 Questions for Drive Applications Application Considerations & Q/A s 2

3 NEMA Trade Association Information NEMA is the trade association of choice for the electrical manufacturing industry. Founded in 1926 and headquartered near Washington, D.C., its approximately 450 member companies manufacture products used in the generation, transmission and distribution, control, and end-use of electricity. 3

4 Exploded Motor View: TEFC NEMA Design Electric Motor 4

5 Subject: The Dumb, Energy Using Electric Motor 5

6 General Industry Electric Motor Energy Nameplate Labeling NEMA Premium Efficient NEMA MG-1 NEMA Energy Efficient /EPACT NEMA MG-1 High Efficiency Standard d Efficiency Definite Purpose Motors Additional Labeling: Inverter Duty Motors 6

7 Example of Premium Efficiency Motor VFD Capabilities and Speed Turndown Specifications from a Major Manufacture s Industrial Motor Catalog. VFD service Capability. Inverter Duty motors utilize a class F insulation system designed for peak voltages of PWM waveform application. Designed to meet and exceed NEMA MG1 Part 31 requirements at either 460V or 575V. Choose between zero to base speed variable torque; 4:1, 6:1, 10:1 or 1000:1 constant torque. Parameters are included in a detailed variable speed design nameplate. Use whenever NEMA Part 31 is required, for quality and reliability. That s why every motor is backed by a three-year warranty for this design. 7

8 Example of a Typical NEMA Premium Efficiency Motor Nameplate, Note: Nom, Eff. 8

9 Example of NEMA Premium. Eff. Chart FULL-LOAD EFFICIENCIES FOR 60 HZ NEMA PREMIUM EFFICIENCY ELECTRIC MOTORS RATED 600 VOLTS OR LESS (RANDOM WOUND) HP TEFC ENCLOSED MOTORS (Data Based From IEEE 112 Method B Testing For Manufactures) 2 POLE 4 POLE 6 POLE HP Nom. Eff. Min. Eff. Nom. Eff. Min. Eff. Nom. Eff. Min. Eff

10 NEMA -National Electrical and Medical Manufactures Association i :Presentation References NEMA-Motor Eff. IEEE112 Method B Testing Procedure and NEMA MG1- Part 31 Inverter Duty Definitions NEMA Application Guide For Ac Adjustable Speed Drives 2007 US Government -EPACT 10

11 What is a VFD? A (VFD) Variable Frequency Drive or DC Drive is like the Gas Peddle on a car, with the AC/DC Motor being the car engine It adjusts the speed of a motor, based on demand, with the added benefit to save energy and prolonging motor and mechanical component life Without a VFD, a motor is either on at full speed, or off period. A VFD/DC Drive eliminates the initial power surge and mechanical shock of switching the motor from 0% to 100% Voltage/Current, just like a soft start. A VFD conserves energy when the control system senses that the motor can meet process needs at lower speed, while running at less than 100% power. 11

12 How Does A VFD Work? It changes the speed of an AC motor by adjusting or varying the frequency and voltage Typical frequency-voltage adjustment range from 10-60Hz AC and V- 3 Phase However this can be increased up-to 400 Hz Proportional changes in the Frequency and Voltage, change motor output speed. Example : Same 1800 RPM Motor, 3 Frequency Settings 1800 RPM AC Motor at 60HZ/480V Setting. 900 RPM AC Motor at 30HZ/230V Setting. 450 RPM AC Motor at 15HZ/115V Setting. 12

13 VFD s What and Why s What Adjustable Speed Controlled Starting Controlled Stopping Why Standard AC Motor Energy Savings Improved Process Control Remote and/or Automated Control Reduced Inrush Current Less Power Line Disturbance. Improved Process Control Reduced d Shock Loading Reduced Maintenance Increased Equipment Life Improved Safety Improved Process Control 13

14 V/T Vs./T Applications Examples Variable Torque Vs. Constant Torque Variable speed drives, and the loads they are applied to, can generally be divided into two groups: constant torque and variable torque. The energy savings potential of variable torque applications is much greater than that of constant torque applications. Variable torque loads include centrifugal pumps and fans, which make up the majority of HVAC applications. Constant torque loads include vibrating conveyors, punch presses, rock crushers, machine tools, and other applications where the drive follows a constant V/Hz ratio 14

15 Why Variable Speed Energy Savings Why Variable Torque Loads Offer Greatest Energy Savings In variable torque applications, the torque required varies with the square of the speed, and the horsepower required varies with the cube of the speed, resulting in a large reduction of horsepower for even a small reduction in speed. The motor will consume only 25% as much energy at 50% speed than it will at 100% speed. This is referred to as the Affinity Laws, which define the relationships between speed, flow, torque, and horsepower. If you have an AC motor-driven application that does not need to be run at full speed, then you can cut down energy costs by controlling the motor with a variable speed drive (VFD, aka variable frequency drive). Variable speed drives allow you to match the speed of the motor-driven equipment to the process requirement. There is no other method of AC motor control that allows you t o accomplish this. 15

16 Affinity Laws Affinity Laws The effects that reduced speed has on a variable torque fan are summarized by a set of rules known as the Affinity Laws. The basis interpretation of these laws is quite simple: 1. Flow produced by the device is proportional to the motor speed. 2. Pressure produced by the device is proportional to the motor speed squared. 3. Horsepower required by the device is proportional to motor speed cubed. For instance, a variable speed drive running a variable torque load at 50 percent speed needs to deliver only 12.5 percent of the horsepower required to run it at 100 percent speed. The reduction of horsepower means that it costs less to run that motor. When these savings are applied over the yearly y hours of operation, a significant savings can accumulate. 16

17 Affinity Table Numeric Description of the Affinity Laws Speed Flow Required Power 100% 100% 100% 90% 90% 73% 80% 80% 50% 70% 70% 34% 60% 60% 22% 50% 50% 13% 40% 40% 6% 30% 30% 3% 17

18 Payback on Variable Torque Applications. VFD Variable Torque drive takes advantage of the affinity laws on variable torque loads such as fans and pumps and does so without altering the voltage or interrupting power to the motor. Even with the motor running continuously, the current and KW required by the motor changes according to the actual load, i.e.: -loading and unloading of the motor by varying the speed of the load via magnetic coupling between the motor and the load. What you always pay for is the amount of KW used and even with the motor running continuously, the difference in the amount of kw required of any 3 phase motor from no load to full load is very significant. ifi 18

19 Example of an Excellent Variable Speed Drive Candidate* 19

20 Example of a Decent Variable Speed Drive Candidate* 20

21 Useful Information: VT Inverters & Motors-Variable Torque Hertz-Voltage = Speed of Motor Example: 10 HP-1800 RPM Inverter Motor, VT Turn Down Ratio On Drive, using Variable Torque of Blower Fan Example: 10 HP-1800 RPM lb-ft =60 Hertz -100% Flow at 100% Speed 73HP 7.3 HP-1620 RPM lb-ft =54 Hertz - 90% Flow at 90% Speed 1.3 HP- 900 RPM 7.58 lb-ft =30 Hertz - 50% Flow at 50% Speed.3 HP- 600 RPM 2.62 lb-ft =20 Hertz - 30% Flow at 30% Speed Torque (in lb-ft) = HP X 5252 Example.3 X 5252 = 2.62 lb-ft Speed d( (In RPM) 600 Major Energy Saving on Variable Torque Motor Drive Applications from the Infinity Laws on Pumps & Fans. 21

22 Variable Torque (VT) Graph 22

23 Electric Motor Energy Facts Simple Payback Formula (.746 X Hp /Mtr. Eff.) X Hours X Days X KW Cost. Electric motors account for more than two-thirds of all energy used in the industrial market place. 63% of all energy consumed is linked to air & liquid flow in a pump or fan application Variable Torque applications. A typical 100 HP industrial motor, with an Nominal Prem. Efficiency value of 95.4 percent costs over $22,770 to operate continuously over a year. Based on 16 Hrs. Per day/260 Days Per Year at.07 KW. in this application, you can buy a new VFD drive below with energy savings. Example 10% Reduction in Speed on V/T VFD, using same scenario of costs, is a energy savings of 27% or $6,147 The average cost of the new VFD drive you are going buy is only going to cost $5,500 plus install and it s free money, purchased with energy savings, and your the hero. 23

24 Energy Savings Comparison Potential energy savings using a VFD vs. modulating flow with a damper In nput Pow wer (%) Speed Reduction 10% = 35% Power Reduction Speed Reduction 20% = 45% Power Reduction Speed Reduction 30% = 65% Power Reduction Energy Saving Potential Damper VFD VT Ideal Fan Control Flow Rate (%) 24

25 Useful Information: CT Inverters & Motors-Constant Torque Example: Hertz-Voltage = Speed of Motor Example: 10 HP-1800 RPM Inverter Motor 10-1, Turn Down Ratio On Drive, using Constant Torque on Conveyor Example: 10 HP-1800 RPM lb-ft =60 Hertz-460 Volt, 7.66 V/Hertz Ratio 100% Speed 7.5HP-1200 RPM lb-ft =45 Hertz-345 Volt, 7.66 V/Hertz Ratio 75% Speed 5.0HP- 900 RPM lb-ft =30 Hertz-230 Volt, 7.66 V/Hertz Ratio 50% Speed 2.5HP- 450 RPM lb-ft =15 Hertz-115 Volt, 7.66 V/Hertz Ratio 25% Speed 1.0HP- 180 RPM lb-ft = 6 Hertz- 46 Volt, 7.66 V/Hertz Ratio 10% Speed Constant Torque= Constant Volts per Hertz ratio Example: 460 V = 7.66 V 230 V = 7.66 V 60 Hertz 30 Hertz Torque (in lb-ft) = HP X 5252 Example 10HP X 5252 = Speed (In RPM) 1800 RPM Torque (in lb-ft) = HP X 5252 Example 5HP X 5252 = Speed (In RPM) 900 RPM CONSTANT TORQUE IS THE SAME WORK( TORQUE ) AVAILABLE AT MOTOR SHAFT AT ALL SPEEDS! 25

26 Constant Torque Graph (CT) 26

27 Keyword is Proper Application of Equipment: Application of Poor Brakes or Just Poor Application Corvette Applied or Misapplied as a Bumper Support Assist Device 27

28 How to select a Motor/Drive 10 Easy Steps What Power do you need (HP/KW) What Voltage (V) & Phase What type of Application (Constant or Variable Torque) What is the temperature/location where the drive is to be mounted What is the distance from the motor to the drive Are there Power Issues, do they have Drives installed now Is Braking required Is there Communications or Automation required What Construction-Enclosure and Eff. of Motor and Speed Range (Turndown) is required for application. What is Manufactures preference of customer and why 28

29 Thank You for Your Time and Hospitality and Courtesy QUESTIONS PLEASE: Handout: Covers Major Slides in Today's Presentation. I recommend you download: NEMA Application Guide For Adjustable Speed Drives Systems 2007 If I can be of further help, I can be reached at the following address or phone, which is: &

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código Letra de código Código de rotor bloqueado Rotor bloqueado, Letra de código kva / hp kva / hp A 0.00 3.15 L 9.00 10.00 B 3.15 3.55 M 10.00 11.00 C 3.55 4.00 N 11.00 12.50 D 4.00 4.50 P 12.50 14.00 E 4.50

More information

Energy Independence & Securities Act Frequently Asked Questions

Energy Independence & Securities Act Frequently Asked Questions What does EISA stand for? Energy Independence & Securities Act Frequently Asked Questions EISA is the acronym for the Energy Independence & Securities Act. This law was signed on Dec. 19, 2007. This law

More information

Variable Speed Drives Controlling Centrifugal Pumps Energy Savings

Variable Speed Drives Controlling Centrifugal Pumps Energy Savings 2018 Clean and Safe Drinking Water Workshop Hotel Gander Variable Speed Drives Controlling Centrifugal Pumps Energy Savings Presenter: Dave Galbraith What is a Variable Speed (Frequency) Drive? AKA VFD,

More information

AND LOAD PARAMETERS IMPORTANT MOTOR. Torque x Speed Constant. Horsepower= Mechanical Power Rating Expressed in either horsepower or watts

AND LOAD PARAMETERS IMPORTANT MOTOR. Torque x Speed Constant. Horsepower= Mechanical Power Rating Expressed in either horsepower or watts MOTOR SELECTION Electric motors should be selected to satisfy the requirements of the machines on which they are applied without exceeding rated electric motor temperature IMPORTANT MOTOR AND LOAD PARAMETERS

More information

Understanding NEMA Motor Nameplates

Understanding NEMA Motor Nameplates Understanding NEMA Motor Nameplates Mission Statement is to be the best (as determined by our customers) marketers, designers and manufacturers of industrial electric motors, mechanical power transmission

More information

Chapter 3.2: Electric Motors

Chapter 3.2: Electric Motors Part I: Objective type questions and answers Chapter 3.2: Electric Motors 1. The synchronous speed of a motor with 6 poles and operating at 50 Hz frequency is. a) 1500 b) 1000 c) 3000 d) 750 2. The efficiency

More information

Jeff Fehr, Senior Application Engineer. ACH550 Flux Optimization White Paper

Jeff Fehr, Senior Application Engineer. ACH550 Flux Optimization White Paper Jeff Fehr, Senior Application Engineer ACH550 Flux Optimization White Paper Table of Contents Executive Summary...3 Introduction...3 Problem Statement...4 ABB Solution...5 Implementation...6 Summary...6

More information

Inverter Speed Ratio Information

Inverter Speed Ratio Information Inverter Speed Ratio Information Guidelines for Application of General Purpose,, Single Speed on Variable Frequency Drives Meets NEMA MG1-2006 Part 30 and Part 31 Section 4.4.2 Unless stated otherwise,

More information

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities. PART 1: GENERAL 1.01 This design guidelines contained herein includes the requirements electric motors utilized for electric motor driven systems at Texas State University. It is the intention of this

More information

Motors & Drives Rebate Application

Motors & Drives Rebate Application Rebate Application Business Member Information Business Name Installation Address City, State, Zip Contact Name Email Phone Number Account Number Rebate Recipient To release the rebate incentive check

More information

30 top tips to tackle HVAC challenges No.09 - Energy efficiency

30 top tips to tackle HVAC challenges No.09 - Energy efficiency ABB DRIVES AND MOTORS 30 top tips to tackle HVAC challenges - Energy efficiency 1 Not all drives count energy use, CO 2 and money Today s variable speed drives (VSDs) offer a wealth of features and smart

More information

IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS

IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS Contents Introduction Where to Find Energy Saving Opportunities Power Transmission System Efficiency Enhancing Motor System Performance

More information

Steve Schouten. Donna Densmore

Steve Schouten. Donna Densmore March 12, 2013 2 Steve Schouten Donna Densmore 3 Mike Carter Justin Kale 4 Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality Issues Source: Emerson Industrial Automation

More information

Measuring Pump Efficiency with Mike Eglitis

Measuring Pump Efficiency with Mike Eglitis Measuring Pump Efficiency with Mike Eglitis Centrifugal Product Specialist since 1995 Mitchell Lewis & Staver Co. Who is MLS? Mitchell Lewis & Staver is the West s premiere value-added integrator of high

More information

The Energy Policy Act. The law s requirements for 1 to 200 horsepower AC motors effective October 24, 1997

The Energy Policy Act. The law s requirements for 1 to 200 horsepower AC motors effective October 24, 1997 The law s requirements for 1 to 200 horsepower AC motors effective October 24, 1997 ELECTRIC COMPANY June 12, 1997 CORPORATE OFFICE 5711 R. S. BOREHAM JR. STREET FORT SMITH, ARKANSAS 72902 U.S.A. PHONE:

More information

It s What s Inside that Counts

It s What s Inside that Counts It s What s Inside that Counts Drive Basics Adjustable Frequency Drive Description: Solid State Device Controls the Frequency and Voltage Speed Range Depends on the Motor HP Range - Fractional to 10,000

More information

Energy Saving Solutions Using Variable Frequency Drives

Energy Saving Solutions Using Variable Frequency Drives Energy Saving Solutions Using Variable Frequency Drives Keystone E April 20 01:00 PM April 21 09:00 AM Presenter: Dan Dillon Energy Efficiency: What s all the fuss about? Rapidly rising energy costs Finite

More information

Realizing Energy Savings in Fan and Pump Systems using Variable Frequency Drives. Schaedler Yesco Expo 2012

Realizing Energy Savings in Fan and Pump Systems using Variable Frequency Drives. Schaedler Yesco Expo 2012 Realizing Energy Savings in Fan and Pump Systems using Variable Frequency Drives Cocoa Suite 4 April 11, 2012 09:30 AM Presenter: Dan Dillon Schaedler Yesco Expo 2012 Energy Savings no-brainer: Motor Efficiency

More information

How to Select a Variable Frequency Drive Based on Load Characteristics

How to Select a Variable Frequency Drive Based on Load Characteristics How to Select a Variable Frequency Drive Based on Load Characteristics by Vishnuvarthanaraj (Vishnu) Balaraj, Software/Hardware Engineer KB Electronics for more information, email: info@kbelectronics.net

More information

Common recommendations

Common recommendations Motor Overview Why are motors important? What is a motor? Optimizing the motor component power factor efficiency and losses motor/load relationships standards Common recommendations Review of CD-ROM Industrial

More information

Motor Efficiency Improvements for Pumping Applications. Brent McManis, P.E. Industry Engineering Manager Baldor Electric: A Member of the ABB Group

Motor Efficiency Improvements for Pumping Applications. Brent McManis, P.E. Industry Engineering Manager Baldor Electric: A Member of the ABB Group Motor Efficiency Improvements for Pumping Applications Brent McManis, P.E. Industry Engineering Manager Baldor Electric: A Member of the ABB Group Participants are in a listen-only mode. To ask a question

More information

AC Adjustable Speed Drives (ASD s)

AC Adjustable Speed Drives (ASD s) Variable Speed ontrol A Adjustable Speed Drives (ASD s) The simplest and least expensive way to control the speed of a process or piece of equipment is to operate all the equipment at full speed. Many

More information

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp

More information

PIP ELEMT01 Guidelines for Selecting IEEE and API Standards for AC Motors 250 HP (185 kw) and Larger

PIP ELEMT01 Guidelines for Selecting IEEE and API Standards for AC Motors 250 HP (185 kw) and Larger COMPLETE REVISION April 2013 Process Industry Practices Electrical PIP ELEMT01 Guidelines for Selecting IEEE and API Standards for AC Motors 250 HP (185 kw) and Larger PURPOSE AND USE OF PROCESS INDUSTRY

More information

Drives and Motor Sizing Made Easy. ABB Inc. October 23, 2014 Slide 1

Drives and Motor Sizing Made Easy. ABB Inc. October 23, 2014 Slide 1 Drives and Motor Sizing Made Easy ABB Inc. October 23, 2014 Slide 1 Drive and motor sizing made easy Size your drive and motor in three easy steps Determine the application requirements Size the motor

More information

Using Variable Speed

Using Variable Speed Potential Energy Savings Using Variable Speed Drives Presented by: Darryl Whitley Our Rules A Dollar not Spent on Energy Is a Dollar of NET PROFIT No consumption of manufacturing capacity No consumption

More information

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings

More information

Variable Frequency Drives

Variable Frequency Drives We Make Energy Engaging Variable Frequency Drives Questline Academy Meet Your Panelist Mike Carter questline.com 2 Contents Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality

More information

Motor Efficiency, Selection and Management. A Guidebook for Industrial Efficiency Programs

Motor Efficiency, Selection and Management. A Guidebook for Industrial Efficiency Programs Motor Efficiency, Selection and Management A Guidebook for Industrial Efficiency Programs For more information, contact: Keith Forsman, P.E. Customer Energy Solutions Core Products Pacific Gas and Electric

More information

Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium

Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium Richard R. Schaefer, Baldor Electric Company ABSTRACT This paper will discuss the latest advances in AC motor design that combines

More information

Motor Basics AGSM 325 Motors vs Engines

Motor Basics AGSM 325 Motors vs Engines Motor Basics AGSM 325 Motors vs Engines Motors convert electrical energy to mechanical energy. Engines convert chemical energy to mechanical energy. 1 Motors Advantages Low Initial Cost - $/Hp Simple &

More information

"Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Tuesday, May 8, Sessions Session 1-8:30-9:25 a.m. Motors 101 Session

Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Tuesday, May 8, Sessions Session 1-8:30-9:25 a.m. Motors 101 Session "Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Tuesday, May 8, 2018 3 Sessions Session 1-8:30-9:25 a.m. Motors 101 Session 2-9:30-10:25 a.m. Power and Motors Session 3-10:30-10:25

More information

AGN 041 Alternator Operating Speed

AGN 041 Alternator Operating Speed Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 041 Alternator Operating Speed INTRODUCTION AvK and STAMFORD synchronous a.c. generators (alternators) are designed

More information

Drive Fundamentals. Motor Control Bootcamp May 15-18, Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC CO900H

Drive Fundamentals. Motor Control Bootcamp May 15-18, Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC CO900H - 5058-CO900H Drive Fundamentals Motor Control Bootcamp May 15-18, 2017 How are these Devices Related? Variable frequency drives Variable speed drives Variable speed controllers Adjustable frequency drives

More information

Industrial and Commercial Duty IEC Motors

Industrial and Commercial Duty IEC Motors Industrial and Commercial Duty IEC Motors A Regal Brand Five product families delivering a world of opportunity LEESON Passport Series IEC Motors. There s a world of opportunity right here at home. The

More information

ENERGY CONSERVATION IN AUTOMATIC FLUID FLOW CONTROL USING VARIABLE FREQUENCY DRIVE

ENERGY CONSERVATION IN AUTOMATIC FLUID FLOW CONTROL USING VARIABLE FREQUENCY DRIVE ENERGY CONSERVATION IN AUTOMATIC FLUID FLOW CONTROL USING VARIABLE FREQUENCY DRIVE Mr. Pinkle J. Bhatt 1, Prof. Aditi R. Hajari 2 1 PG Student, Electrical Engineering Department, SCET, Surat,( India) 2

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

Energy Efficient Motors

Energy Efficient Motors Energy Efficient Motors Why High Efficiency Motors? Electric motors responsible for 40% of global electricity usage Drive pumps, fans, compressors, and many other mechanical traction equipment International

More information

Premium Efficiency Motor Rebate Program (Retrofit Applications) Efficiency Requirements Page

Premium Efficiency Motor Rebate Program (Retrofit Applications) Efficiency Requirements Page 2017 Premium Efficiency Program (Retrofit Applications) Efficiency Requirements Page Premium Efficiency Motor Standards Open DripProof (ODP) Totally Enclosed FanCooled (TEFC) 1200 1800 3600 1200 1800 3600

More information

EPACT ENERGY POLICY ACT OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER

EPACT ENERGY POLICY ACT OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER EPACT ENERGY POLICY OF 1992: THE SCOPE OF ELECTRIC MOTORS SUBJECT TO EFFICIENCY STANDARDS ON OCTOBER 24, 1997 The Energy Policy Act of 1992 (EPAct) covering efficiency levels of general purpose industrial

More information

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT SECTION 22 05 12 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable in the section

More information

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL Design Standard Detailed specifications follow. PART 1 - GENERAL 1.01 SCOPE This design guidelines contained herein include the requirements of electric motors utilized for electric motor driven systems

More information

How do you take the first step towards an energy efficient future?

How do you take the first step towards an energy efficient future? How do you take the first step towards an energy efficient future? Low-voltage induction motors according to the new standard and new classes Answers for industry. EU Directive 2005/32/EC and IEC 60034-30

More information

Best Practice High Eff iciency Motors

Best Practice High Eff iciency Motors Best Practice High Eff iciency Motors Contents 1 Introduction 3 2 Recommendations 4 3 Importance of improving motor eff iciency 5 4 When should you consider buying an energy-eff icient motor? 6 5 Financial

More information

S R ATE TOO EG M R G G A

S R ATE TOO EG M R G G A MOTORS AGGREGATE AGGREGATE MOTORS THE RIGHT PRODUCT IN THE TOUGHEST CONDITIONS For decades, aggregate operators have come to depend on Baldor products to keep their facilities operating at optimum efficiency

More information

Blue Chip Severe Duty / Cooling Tower: Single Speed EPAct Efficiency

Blue Chip Severe Duty / Cooling Tower: Single Speed EPAct Efficiency Blue Chip Severe Duty / Cooling Tower: Single Speed EPAct Efficiency Rigid Base, Three Phase IP55 Features: Blue Chip quality, 100% cast iron construction for rigidity and reduced vibration Internal and

More information

30% and Higher Energy Savings with EC Motors. BUILDINGSNY.COM Javits Center, NY March 21-22, 2017

30% and Higher Energy Savings with EC Motors. BUILDINGSNY.COM Javits Center, NY March 21-22, 2017 30% and Higher Energy Savings with EC Motors BUILDINGSNY.COM Javits Center, NY March 21-22, 2017 The Strategic Horsepower to Drive Efficiency GREENCROWN Motor Solutions Moderated by: Ron Zeccardi Paul

More information

PUSHING MOTOR EFFICIENCY TO THE LIMIT

PUSHING MOTOR EFFICIENCY TO THE LIMIT PUSHING MOTOR EFFICIENCY TO THE LIMIT Federal legislation mandating energy efficiency standards promise more reliable electric motors and lower operating costs for equipment manufacturers A Reliance E!ecW

More information

Building Bridges to Net Zero Adjustable Speed Motor and VFD Applications and Opportunities in Multifamily Buildings

Building Bridges to Net Zero Adjustable Speed Motor and VFD Applications and Opportunities in Multifamily Buildings Building Bridges to Net Zero Adjustable Speed Motor and VFD Applications and Opportunities in Multifamily Buildings Andrew Brooks Nick Dirr Types of Motors: AC Induction Motor Permanent Magnet AC Motor

More information

NEMA & IEC Product Features and Benefits

NEMA & IEC Product Features and Benefits NEMA & IEC Product Features and Benefits BEAUTY BENEATH THE SURFACE. Looking at a Techtop electric motor, it would be understandable if you thought it was just another NEMA or IEC squirrel-cage induction

More information

Name : Tushar Patankar Division : LT Motors Category : General

Name : Tushar Patankar Division : LT Motors Category : General Welcome 1 Name : Tushar Patankar Division : LT Motors Category : General 2 Avantha Group CG, 75 year old company, employs more than 10000 people in 21 countries. With several international acquisitions,

More information

Variable Frequency Drive Basics

Variable Frequency Drive Basics Variable Frequency Drive Basics Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq Variable Frequency Drives are

More information

Energy Savings Variable Frequency Drives and Cooling Tower Fan Motors

Energy Savings Variable Frequency Drives and Cooling Tower Fan Motors Contacts: Head Office: Ecodyne Limited 4475 Corporate Drive Burlington, ON L7L 5T9 Phone: (905) 33-1404 Fax: (905) 33-676 1-888-ECODYNE Paul Holmes Manager Cooling Products paul.holmes@ecodyne.com Jim

More information

AutomationDirect AC Motors Selection Overview

AutomationDirect AC Motors Selection Overview AutomationDirect AC s Selection (1992), High, What does it all mean? In 1992, the U.S. Congress passed legislation requiring that general purpose Design A & B motors meet minimum efficiency requirements,

More information

Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please

Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please click the Notes button in the bottom right corner. 1 After

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

LT Motors. Efficiency level1 motors Cat No: LTM/Cat/01/Dec.2009

LT Motors. Efficiency level1 motors Cat No: LTM/Cat/01/Dec.2009 LT Motors Efficiency level1 motors Cat No: LTM/Cat/01/Dec.2009 Energy Efficient Motors - Level I 0.37 kw to 225 kw From 80 to 355 Frame EFF Level 1 ENERGY EFFICIENT MOTORS LEVEL 1 Crompton Greaves has

More information

Variable Speed Motor Products

Variable Speed Motor Products Variable Motor Products Why Baldor? Customer Preference 90% 2000 20% 1985 50% 1990 Percentage of research studies in which Baldor was chosen most preferred. For nearly 100 years, Baldor has strived to

More information

REDUCING ENERGY CONSUMPTION IN WATER PUMPING STATIONS

REDUCING ENERGY CONSUMPTION IN WATER PUMPING STATIONS 2014 Water Workshop REDUCING ENERGY CONSUMPTION IN WATER PUMPING STATIONS Tom Sherman CEM, CDSM President Sustainable Energy Services, Inc. 440.773.5044 Tom@Sustainable-Energy-Services.com THE ROAD TO

More information

SMC -50 Technology and Control Advances

SMC -50 Technology and Control Advances White Paper SMC -50 Technology and Control Advances Sensorless Linear Acceleration and Energy Management Topic Page Introduction 2 Energy Effectiveness with Appropriate Starting Method 3 SMC-50 Starting

More information

SECTION VARIABLE FREQUENCY DRIVE UNITS

SECTION VARIABLE FREQUENCY DRIVE UNITS SECTION 26 29 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide variable frequency drive (VFD) units, complete and operable, in accordance with the Contract Documents. It

More information

NEMA MOTORS. Aggregate motors

NEMA MOTORS. Aggregate motors NEMA MOTORS Aggregate motors 2 AGGREGATE MOTORS Aggregate motors The right product in the toughest conditions Building on the rich history of our mechanical power transmission products, you can expect

More information

A Full Line of Low Voltage IEC Motors In-Stock

A Full Line of Low Voltage IEC Motors In-Stock BUILT TO PERFORM WHERE OTHERS FAIL A Full Line of Low Voltage IEC Motors In-Stock Distributed by Elektrim Motors Authorized Distributor: www.elektrimmotors.com or call 855-Go-Elektrim 0.08-220HP Low Voltage

More information

ELECTRIC MOTORS, MOTOR MANAGEMENT, AND VARIABLE SPEED DRIVES SECTION M

ELECTRIC MOTORS, MOTOR MANAGEMENT, AND VARIABLE SPEED DRIVES SECTION M ELECTRIC MOTORS, MOTOR MANAGEMENT, AND VARIABLE SPEED DRIVES SECTION M ELECTRIC MOTOR MANAGEMENT Why bother? Electric motor basics Electricity and electric motors Energy efficient electric motors Electric

More information

3/29/2012 ELECTRIC MOTORS, MOTOR MANAGEMENT, AND VARIABLE SPEED DRIVES SECTION M WHY SO DIFFICULT? ELECTRIC MOTOR MANAGEMENT WHY BOTHER?

3/29/2012 ELECTRIC MOTORS, MOTOR MANAGEMENT, AND VARIABLE SPEED DRIVES SECTION M WHY SO DIFFICULT? ELECTRIC MOTOR MANAGEMENT WHY BOTHER? ELECTRIC MOTORS, MOTOR MANAGEMENT, AND VARIABLE SPEED DRIVES SECTION M Why bother? Electric motor basics Electricity and electric motors Energy efficient electric motors Electric motor inventories and

More information

The Perfect Fit. Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive. usa.siemens.

The Perfect Fit. Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive. usa.siemens. The Perfect Fit Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive usa.siemens.com/perfectharmony When reliability is all you have room for. When it comes to improving throughput,

More information

Sensible flow saves Variable Speed Drives (VSDs) saving energy in the industrial sector

Sensible flow saves Variable Speed Drives (VSDs) saving energy in the industrial sector Sensible flow saves Variable Speed Drives (VSDs) saving energy in the industrial sector 124541ESKD VS Brochure.indd 1 2010/09/20 2:49 PM 124541ESKD VS Brochure.indd 2 Contents page Variable Speed Drives

More information

Your Source for a Complete Line of Electric Motors. Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors

Your Source for a Complete Line of Electric Motors. Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors Your Source for a Complete Line of Electric Motors Rolled Steel Motors A Complete Line of Single Phase and Three Phase Rolled Steel Motors Mission Statement To provide the United States market for industrial

More information

ET 332b Ac Motors, Generators and Power Systems. lesson14_et332b.pptx. Learning Objectives. After this presentation you will be able to:

ET 332b Ac Motors, Generators and Power Systems. lesson14_et332b.pptx. Learning Objectives. After this presentation you will be able to: ET 332b Ac Motors, Generators and Power Systems lesson14_et332b.pptx 1 Learning Objectives After this presentation you will be able to: List the characteristics of NEMA Design motors. Identify and interpret

More information

Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors

Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors Rolled Steel Motors A Complete Line of Single Phase and Three Phase Rolled Steel Motors SINGLE PHASE, TEFC, 56C FRAME 1/3-2 Horse Power 1800 and 3600 RPM C-Flange with Removable Feet High Starting Torque

More information

CHAPTER 3 EFFICIENCY IMPROVEMENT IN CAGE INDUCTION MOTORS BY USING DCR TECHNOLOGY

CHAPTER 3 EFFICIENCY IMPROVEMENT IN CAGE INDUCTION MOTORS BY USING DCR TECHNOLOGY 37 CHAPTER 3 EFFICIENCY IMPROVEMENT IN CAGE INDUCTION MOTORS BY USING DCR TECHNOLOGY 3.1 INTRODUCTION This chapter describes, a comparison of the performance characteristics of a 2.2 kw induction motor

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6 I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load

More information

Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754

Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754 Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Prescriptive Program Rebate Application

Prescriptive Program Rebate Application Prescriptive Program Rebate Check the appropriate program box for your rebate. Cooling FSO (Fluid System Optimization) Foodservice Equipment Heating Lighting Motors and Drives Customer information Xcel

More information

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS HPS CENTURION R REACTORS AND RC DV/DT FILTERS Single and Three Phase Why Choose a Line Reactor?... 98 Construction Features... 100 HPS Centurion R Reactors Specifications... 101 Part Number Guide... 102

More information

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features TM WEG W21 Severe Duty motors meet the most demanding severe duty application requirements. These TEFC motors are all cast iron construction, with enclosures rated IP55 to handle wet and dirty environments.

More information

Table 1. Lubrication Guide

Table 1. Lubrication Guide Lubrication. Too much lubricant is a major cause of premature motor failure. Excess grease is eventually forced out of the bearing housings and begins dripping on the motor windings, resulting in early

More information

MAX-E1 HIGH EFFICIENCY. Severe Duty

MAX-E1 HIGH EFFICIENCY. Severe Duty MAX-E1 HIGH EFFICIENCY Severe Duty DESIGN FEATURES & CONSTRUCTION ALL MAX-E1 MOTORS DELIVER THESE IMPRESSIVE DESIGN FEATURES HPE - High Pulse Endurance Wire Non-hygroscopic, Class F insulation system High-grade,

More information

Oftentimes, that isn't the end of the story for the engineer.

Oftentimes, that isn't the end of the story for the engineer. How to select a VFD These guidelines dispel the confusion about matching variable frequency drives (VFD) and motors to fans and pumps that are typically encountered in commercial building applications.

More information

How to implement higher efficiency motors

How to implement higher efficiency motors How to implement higher efficiency motors Higher efficiency motors (HEMs) cost less to run than conventional motors. The savings they realise can quickly outweigh their additional cost to purchase, and

More information

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER

More information

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date: CSDA Best Practice Title: Hi-Cycle Concrete Cutting Equipment Issue No: CSDA-BP-010 : Oct 1, 2010 Revised : Introduction Hi-cycle/high frequency concrete cutting equipment has become more prevalent in

More information

ECET 211 Electric Machines & Controls Lecture 5-4 Electric Motors. Lecture 5-4 Electric Motors

ECET 211 Electric Machines & Controls Lecture 5-4 Electric Motors. Lecture 5-4 Electric Motors ECET 211 Electric Machines & Controls Lecture 5-4 Electric Motors (4 of 4) Text Book: Chapter 5 Electric Motors, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015.

More information

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters MSC - 3 1100VAC Variable Speed Drive Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters Why Variable Speed Drive? Process automation & productivity

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Motors Automation Energy Coatings. CrusherDuty. g Roller Bearing. g Reinforced Cast Iron. g Durable. Motor TPH Starter.

Motors Automation Energy Coatings. CrusherDuty. g Roller Bearing. g Reinforced Cast Iron. g Durable. Motor TPH Starter. Motors Automation Energy Coatings CrusherDuty Motor TPH Starter g Roller Bearing g Reinforced Cast Iron g Durable g Quality CD0808 FOR THE MOST DEMANDING ROCK CRUSHER APPLICATIONS WEG Crusher Duty motors

More information

PAC TRAINING PUMP MOTORS

PAC TRAINING PUMP MOTORS PAC TRAINING PUMP MOTORS 1 Basics Magnet supported from above N S N S Since unlike poles repel each other, the magnet will rotate Stationary Magnet 2 Basics N S Stationary Magnet 3 Basics N N S S Stationary

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Twenty Ways to Optimize Energy Efficiency in the Use of Induction Motors

Twenty Ways to Optimize Energy Efficiency in the Use of Induction Motors Twenty Ways to Optimize Energy Efficiency in the Use of Induction Motors Course No: M06-021 Credit: 6 PDH A. Bhatia Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

You have probably noticed that there are several camps

You have probably noticed that there are several camps Pump Ed 101 Joe Evans, Ph.D. Comparing Energy Consumption: To VFD or Not to VFD You have probably noticed that there are several camps out there when it comes to centrifugal pump applications involving

More information

Variable Speed Pumping

Variable Speed Pumping Variable Speed Pumping Jim Vukich Application Engineer ITT Corp. Malvern, PA Why Do It? Why Do It? Flow-Matching Minimize Starting & Stopping Flexibility Different Discharge Points, Flows Changing Conditions

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

ECE1750, Spring Motor Drives and Other

ECE1750, Spring Motor Drives and Other ECE1750, Spring 2018 Motor Drives and Other Applications 1 Three-Phase Induction Motors Reliable Rugged Long lived Low maintenance Efficient (Source: EPRI Adjustable Speed Drives Application Guide) The

More information

Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1

Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1 Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

Five Reasons for VFDs in HVAC Applications

Five Reasons for VFDs in HVAC Applications Five Reasons for VFDs in HVAC Applications Save Money and Improve Performance with HVAC-Specific Drives by Larry Gardner, Yaskawa America, Inc., HVAC Drives Product Marketing Manager yaskawa.com Introduction

More information

MOTOR WINDING INSULATION TESTING

MOTOR WINDING INSULATION TESTING 1 MOTOR WINDING INSULATION TESTING 237 237 237 217 217 217 200 200 200 80 119 27 252 174.59 255 255 255 0 0 0 163 163 163 131 132 122 239 65 53 110 135 120 112 92 56 62 102 130 102 56 48 130 120 111 AKA

More information

MASTERDRIVE Compact Plus

MASTERDRIVE Compact Plus MASTERDRIVE Compact Plus The Compact Plus is a member of the MASTERDRIVE product line. The Compact Plus offers many of the same features as the larger MASTERDRIVE products in a smaller package. Compact

More information

TTM-04: The relationship of system efficiency and speed control using VSDs vs. EC motors

TTM-04: The relationship of system efficiency and speed control using VSDs vs. EC motors August 2016 TTM-0: The relationship of system efficiency and speed control using VSDs vs. EC motors Kunal Pental, Sales Manager NSW & QLD, ebm-papst A&NZ 1 Introduction In an effort to reduce energy consumption,

More information