Full Voltage Starting (Number of Starts):

Size: px
Start display at page:

Download "Full Voltage Starting (Number of Starts):"

Transcription

1 Starting Method Full Voltage Starting (Number of Starts): Squirrel cage induction motors are designed to accelerate a NEMA inertia along a NEMA load curve with rated voltage applied to the motor terminals. With the motor initially at ambient temperature, it may be started twice in succession coasting to rest between starts, or once the motor has reached the rated load operating temperature it may be stopped, coasting to rest, and restarted immediately, providing the WK2 inertia of the load, the load torque during acceleration, the applied voltage and the method of starting are those for which the motor was designed. Note: When more frequent starting is necessary contact the Large AC Sales Team for pricing, frame size and availability. 23 ABB Motors and Mechanical Inc.

2 Voltage Dip (also known as Reduced Voltage Starting): Squirrel cage induction motors for pumps and fans are capable of accelerating the specified load inertia in WK2 with the specified load starting conditions when the motor terminal voltage does not drop below 90 percent of the nominal voltage. This applies only to ratings utilizing normal inrush current. Exception: When the load WK2 is not more that 1/2 of the NEMA normal values and where the load torque varying as the square of the speed does not exceed 60 percent of motor rated torque during the acceleration period, no price addition is required for terminal voltage down to 70 percent of rated. Notes: 1. Where motor is to accelerate a load WK2 greater than NEMA normal also make price addition for high WK2 2. Do not use this option where non-standard starting torques are required. 3. Motors designed for low voltage starting conditions may have higher than 650% inrush current at full voltage and lower than listed efficiency and power factor. 4. Customer load speed torque curve required prior to order acceptance. 24 ABB Motors and Mechanical Inc.

3 Electronic Soft Starting: Electronic Soft-starting is used to either limit the inrush current or to limit the torque in order to reduce the strain on the mechanical system. There are two basic kinds of electronic soft-starters: voltage ramp and current limit. In either type of device, the user pre-sets an initial voltage and ramp time or current limit that will reduce the torque available from the motor. The following data must be supplied to insure proper application of the motor: 1. Will voltage ramp or current limit be used? 2. What is the current limit and time (if applicable)? 3. What is the initial voltage and ramp time (if applicable)? 4. Provide driven equipment load speed vs. torque curve. 5. Provide Load inertia (reflected at the motor shaft). 25 ABB Motors and Mechanical Inc.

4 Wye Start-Delta Run: The motor normally operates while running as a delta connected stator. At start, the stator is connected as a wye winding and draws only 1/3 locked rotor current of the delta connected winding. This is because the phase voltage and current in the wye connection is 1/3 times the phase voltage and current in the delta connection. The starting torque is decreased to approximately 1/3 of its value for the delta or running connection, since the change from delta to wye decreases the phase voltage to 1/3 of its original value and the torque is proportional to the square of the phase voltage. After the motor has reached a certain predetermined speed, or locked current value, a timer in the control panel actuates the starter contacts and switches the winding connection from wye to delta. The motor now develops full design running torque to produce rated horsepower. The control timer is usually set for 5-8 seconds, so the value of locked rotor current drawn by the delta connected winding at switch over is not much greater than the initial locked current on the wye at startup. This method is often termed Star-Delta starting. Note: This feature is only practical for low voltage (typically 380 or 460V). 26 ABB Motors and Mechanical Inc.

5 Reactor starting: Despite the simplicity and reliability of the polyphase induction motor, high inrush current limited its usefulness in the early years of weak power system capability. This led to the use of series resistance during starting, to reduce that current. As motor size increased, such resistors required high power dissipation capability, and the autotransformer, or "starting compensator," became popular. An alternative was replacement of series resistance by series reactance. Although the solid-state electronic starter is now popular for motors under 375 kw, especially below 600 volts, the motor starting reactor is still used for many large machines and at voltages up to 11,000. Although some starting reactors are of the air-core type, most contain iron cores because such cores provide higher reactance in a smaller space. One reactor is usually connected in each phase, bypassed by a contactor once the motor reaches full speed. Alternatively, reactors are inserted in the neutral side of a wyeconnected stator winding. This permits a lower level of reactor insulation. A less-common scheme includes a single reactor in only one phase, resulting in phase voltage unbalance that reduces total kva supplied to the accelerating motor. 27 ABB Motors and Mechanical Inc.

6 Reactor starting (Cont.): Reactor starting always reduces motor accelerating torque. Voltage reduction in the reactor is not fixed, as with an autotransformer, but varies with the current. Since this current is determined by total circuit impedance, motor voltage during acceleration depends upon the relative reactor and motor impedances. Complete circuit analysis, and choice of reactor characteristics, involves the vectorial relationships among the circuit voltages and the current. Reactor opposition to current flow, unlike series resistance, is not necessarily a constant for all values of current. That's because of magnetic saturation in the reactor core. In some starters the reactors are "saturable"; that is, a separate control winding on the same core allows an external control voltage to vary the saturation and therefore the reactor impedance. Control voltage may be fed back directly or indirectly from the counter EMF of the accelerating motor. 28 ABB Motors and Mechanical Inc.

Starting of Induction Motors

Starting of Induction Motors 1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding

More information

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc. Chapter 2 MOTOR CLASSIFICATION 1 In general, motors are classified according to the type of power used (AC or DC) and the motor's principle of operation. AC DC Motor Family Tree 2 DC MOTOR CONNECTIONS

More information

Electrical Drives I. Week 11: Three phase Induction Motor Starting

Electrical Drives I. Week 11: Three phase Induction Motor Starting Electrical Drives I Week 11: Three phase Induction otor Starting Starting Problem Definition: ' I r Rs Vs 2 R ' r S 2 Xeq At S=0 and S=1, thus the current can be determined as: ' I r st Vs 2 ' Rs Rr Xeq

More information

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase motor? Stator and Rotor 2. Which part of a three-phase squirrel-cage induction motor is a

More information

Induction Motor Control

Induction Motor Control Induction Motor Control A much misunderstood yet vitally important facet of electrical engineering. The Induction Motor A very major consumer of electrical energy in industry today. The major source of

More information

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT BALDOR -RELIANCE FRAME HP TYPE PHASE HERTZ RPM SALES ORDER 385- O58 5 P 3 6 3576 VOLTS AMPS DUTY AMB o C INSUL S.F. NEMA DESIGN 3 / 46 36 / 8 CONT 4 F.5 --- CODE ENCL. ROTOR WK STATOR RES.@5 o C LETTER

More information

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1 University f Jordan School of Engineering Department of Mechatronics Engineering Electrical Machines Lab Eng. Osama Fuad Eng. Nazmi Ashour EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1 OBJECTIVES To

More information

Spec Information. Reactances Per Unit Ohms

Spec Information. Reactances Per Unit Ohms GENERATOR DATA Selected Model Spec Information Generator Specification Frame: 687 Type: SR4 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 521.0 Connection: SERIES STAR Housing: 00 Phases: 3 No.

More information

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase 2. Which part of a three-phase squirrel-cage induction motor is a hollow core? 3. What are

More information

PERFORMANCE - DELTA CONNECTION LOAD HP AMPERES RPM % % SPEED TORQUE - WYE / DELTA CONNECTION RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT 61 / 219

PERFORMANCE - DELTA CONNECTION LOAD HP AMPERES RPM % % SPEED TORQUE - WYE / DELTA CONNECTION RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT 61 / 219 BALDOR -RELIANCE FRAME HP TYPE PHASE HERTZ RPM SALES ORDER 347778- E58 4 P 3 6 784 VOLTS AMPS DUTY AMB o C INSUL S.F. NEMA DESIGN 38 566 CONT 46 F.5 --- CODE ENCL. ROTOR WK STATOR RES.@5 o C LETTER (lb-ft

More information

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications 38. Paint (continued) The motor will be painted with Nidec Motor Corporation s standard paint used for CORRO-DUTY motors (unless Special Paint is specified), including: On Open Motors: exterior of motor,

More information

GENERATOR DATA MAY 10, 2018

GENERATOR DATA MAY 10, 2018 Page 1 of 10 GENERATOR DATA MAY 10, 2018 For Help Desk Phone Numbers Click here Spec Information Generator Specification Frame: 449 Type: SR4 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 14.0

More information

ESO 210 Introduction to Electrical Engineering

ESO 210 Introduction to Electrical Engineering ESO 210 Introduction to Electrical Engineering Lectures-37 Polyphase (3-phase) Induction Motor 2 Determination of Induction Machine Parameters Three tests are needed to determine the parameters in an induction

More information

GENERATOR DATA SEPTEMBER 29, 2015

GENERATOR DATA SEPTEMBER 29, 2015 Page 1 of 10 GENERATOR DATA SEPTEMBER 29, 2015 For Help Desk Phone Numbers Click here Spec Information Generator Specification Frame: 685 Type: SR4 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel:

More information

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código Letra de código Código de rotor bloqueado Rotor bloqueado, Letra de código kva / hp kva / hp A 0.00 3.15 L 9.00 10.00 B 3.15 3.55 M 10.00 11.00 C 3.55 4.00 N 11.00 12.50 D 4.00 4.50 P 12.50 14.00 E 4.50

More information

Chapter 3.2: Electric Motors

Chapter 3.2: Electric Motors Part I: Objective type questions and answers Chapter 3.2: Electric Motors 1. The synchronous speed of a motor with 6 poles and operating at 50 Hz frequency is. a) 1500 b) 1000 c) 3000 d) 750 2. The efficiency

More information

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE VOLT CONNECTION(S). IF OTHER VOLTAGE CONNECTIONS ARE AVAILABLE, THE AMPERES WILL

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE VOLT CONNECTION(S). IF OTHER VOLTAGE CONNECTIONS ARE AVAILABLE, THE AMPERES WILL BALDOR -RELIANCE FRAME HP TYPE PHASE HERTZ RPM SALES ORDER 385-7 E588 7 P 3 6 3577 VOLTS AMPS DUTY AMB o C INSUL S.F. NEMA DESIGN 3 / 46 58 / 87 CONT 46 F.5 --- CODE ENCL. ROTOR WK STATOR RES.@5 o C LETTER

More information

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter Direct On Line (DOL) Motor Starter Direct Online Motor Starter Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting.

More information

Motor Protection Fundamentals. Motor Protection - Agenda

Motor Protection Fundamentals. Motor Protection - Agenda Motor Protection Fundamentals IEEE SF Power and Energy Society May 29, 2015 Ali Kazemi, PE Regional Technical Manager Schweitzer Engineering Laboratories Irvine, CA Copyright SEL 2015 Motor Protection

More information

PAC TRAINING PUMP MOTORS

PAC TRAINING PUMP MOTORS PAC TRAINING PUMP MOTORS 1 Basics Magnet supported from above N S N S Since unlike poles repel each other, the magnet will rotate Stationary Magnet 2 Basics N S Stationary Magnet 3 Basics N N S S Stationary

More information

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of

More information

Question Number: 1. (a)

Question Number: 1. (a) Session: Summer 2008 Page: 1of 8 Question Number: 1 (a) A single winding machine cannot generate starting torque. During starting the switch connects the starting winding via the capacitor. The capacitor

More information

MAIN ELECTRIC MOTOR 900 HP 4000 V 60 HZ MAKE: RELIANCE ELECTRIC

MAIN ELECTRIC MOTOR 900 HP 4000 V 60 HZ MAKE: RELIANCE ELECTRIC MAIN ELECTRIC MOTOR 9 HP 4 V 6 HZ MAKE: RELIANCE ELECTRIC E.I DUPONT DE NEMOURS & CO. COOPER RIVER PROJECT PROJ: 76P PO: # LCRCP-5W RELIANCE FRAME HP TYPE PHASE HERTZ RPM SALES ORDER B795 588 9 P 6

More information

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines Department of Electrical Engineering Lecture Introduction to Electrical Machines 1 In this Lecture Induction motors and synchronous machines are introduced Production of rotating magnetic field Three-phase

More information

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1... 100HP 400HP 700HP 1000HP 1400HP PCS Softstarter Controller IN-rail mountable microprocessor controller for 3-phase motors up to 480A (3...85A din-rail mountable) Provides three different starting modes

More information

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION 1. What is meant by drive and electric drive? Machines employed for motion control are called drives and may employ any one of the prime movers for

More information

Modifiable TITAN Horizontal Motors Accessories and Modifications

Modifiable TITAN Horizontal Motors Accessories and Modifications 36. Rotor, Standard And Optional Construction Standard rotor construction of 449, 5000 and 5800 frame TITAN products is typically die-cast aluminum. 720 RPM and slower is typically fabricated aluminum.

More information

Three-Phase Induction Motor With Frequency Inverter

Three-Phase Induction Motor With Frequency Inverter Objectives Experiment 9 Three-Phase Induction Motor With Frequency Inverter To be familiar with the 3-phase induction motor different configuration. To control the speed of the motor using a frequency

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

AC MOTOR TYPES. DESCRIBE how torque is produced in a single-phase AC motor. EXPLAIN why an AC synchronous motor does not have starting torque.

AC MOTOR TYPES. DESCRIBE how torque is produced in a single-phase AC motor. EXPLAIN why an AC synchronous motor does not have starting torque. Various types of AC motors are used for specific applications. By matching the type of motor to the appropriate application, increased equipment performance can be obtained. EO 1.5 EO 1.6 EO 1.7 EO 1.8

More information

ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits

ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Text Book: Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai Lin, Professor

More information

The Wound-Rotor Induction Motor Part I

The Wound-Rotor Induction Motor Part I Experiment 1 The Wound-Rotor Induction Motor Part I OBJECTIVE To examine the construction of the three-phase wound-rotor induction motor. To understand exciting current, synchronous speed and slip in a

More information

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1 It is the mark of an educated mind to be able to entertain a thought without accepting it. DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1 1. Explain the Basic concepts of rotating machine. 2. With help

More information

Electrical Motor Controls (Fourth Edition)

Electrical Motor Controls (Fourth Edition) Electrical Motor Controls (Fourth Edition) 1. Which drawing type shows physical details as seen by the eye? Pictorial Drawing 2. Which drawing is similar to a pictorial drawing but has circles or rectangles

More information

Regulation: R16 Course & Branch: B.Tech EEE

Regulation: R16 Course & Branch: B.Tech EEE SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road 517583 QUESTION BANK (Descriptive) Subject with Code : Electrical Machines-II (16EE215) Regulation: R16 Course & Branch: B.Tech

More information

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK 16EET41 SYNCHRONOUS AND INDUCTION MACHINES UNIT I SYNCHRONOUS GENERATOR 1. Why the stator core is laminated? 2. Define voltage regulation

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

DC CIRCUITS ELECTROMAGNETISM

DC CIRCUITS ELECTROMAGNETISM DC CIRCUITS 1. State and Explain Ohm s Law. Write in brief about the limitations of Ohm s Law. 2. State and explain Kirchhoff s laws. 3. Write in brief about disadvantages of series circuit and advantages

More information

Principles of iers (intelligent

Principles of iers (intelligent Principles of iers (intelligent Energy Recovery System) Chapter 4 Table of Contents............... 4 1 Principles of the iers....................................... 4 2 Enabling Intelligent Energy Recovery

More information

10. Starting Method for Induction Motors

10. Starting Method for Induction Motors 10. Starting Method for Induction Motors A 3-phase induction motor is theoretically self starting. The stator of an induction motor consists of 3-phase windings, which when connected to a 3-phase supply

More information

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING ME 6351 ELECTRICAL DRIVES AND CONTROL UNIVERSITY QUESTIONS AND ANSWERS

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING ME 6351 ELECTRICAL DRIVES AND CONTROL UNIVERSITY QUESTIONS AND ANSWERS DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING ME 6351 ELECTRICAL DRIVES AND CONTROL UNIVERSITY QUESTIONS AND ANSWERS 1) What is the Necessity of starter? UNIT 3 Two Marks Both

More information

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB Relion. Thinking beyond the box. Designed to seamlessly consolidate functions, Relion relays are smarter,

More information

694 Electric Machines

694 Electric Machines 694 Electric Machines 9.1 A 4-pole wound-rotor induction motor is used as a frequency changer. The stator is connected to a 50 Hz, 3-phase supply. The load is connected to the rotor slip rings. What are

More information

SOLSTART Instruction Manual

SOLSTART Instruction Manual Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

Electrical Machines -II

Electrical Machines -II Objective Type Questions: 1. Basically induction machine was invented by (a) Thomas Alva Edison (b) Fleming (c) Nikola Tesla (d) Michel Faraday Electrical Machines -II 2. What will be the amplitude and

More information

ROTATING MAGNETIC FIELD

ROTATING MAGNETIC FIELD Chapter 5 ROTATING MAGNETIC FIELD 1 A rotating magnetic field is the key to the operation of AC motors. The magnetic field of the stator is made to rotate electrically around and around in a circle. Stator

More information

Fachpraktikum Elektrische Maschinen. Experiments with a 400/ 690 V Squirrel Cage Induction Machine

Fachpraktikum Elektrische Maschinen. Experiments with a 400/ 690 V Squirrel Cage Induction Machine Fachpraktikum Elektrische Maschinen Experiments with a 400/ 690 V Squirrel Cage Induction Machine Prepared by Arda Tüysüz January 2013 1. Questions to answer before the experiment - Describe the operation

More information

RVS-AX Instruction Manual

RVS-AX Instruction Manual RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3

More information

MOTOR TERMINAL CONNECTIONS

MOTOR TERMINAL CONNECTIONS MOTOR TERMINAL CONNECTIONS Motor Classification Most of the industrial machines in use today are driven by electric motors Motors are classified according to the type of power used (AC or DC) and the motors

More information

2. Draw the speed-torque characteristics of dc shunt motor and series motor. (May2013) (May 2014)

2. Draw the speed-torque characteristics of dc shunt motor and series motor. (May2013) (May 2014) UNIT 2 - DRIVE MOTOR CHARACTERISTICS PART A 1. What is meant by mechanical characteristics? A curve is drawn between speed-torque. This characteristic is called mechanical characteristics. 2. Draw the

More information

R07 SET - 1

R07 SET - 1 R07 SET - 1 II B. Tech II Semester Supplementary Examinations April/May 2013 ELECTRICAL MACHINES - II (Electrical and Electronics Engineering) Time: 3 hours Max. Marks: 80 Answer any FIVE Questions All

More information

ECET Industrial Motor Control. NEMA Ratings. National Electrical Manufacturers Association

ECET Industrial Motor Control. NEMA Ratings. National Electrical Manufacturers Association ECET 4530 Industrial Motor Control NEMA Ratings National Electrical Manufacturers Association NEMA * Trade association whose 400+ member companies manufacture products used in the generation, transmission,

More information

HCI634V - Technical Data Sheet

HCI634V - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

Motor Basics AGSM 325 Motors vs Engines

Motor Basics AGSM 325 Motors vs Engines Motor Basics AGSM 325 Motors vs Engines Motors convert electrical energy to mechanical energy. Engines convert chemical energy to mechanical energy. 1 Motors Advantages Low Initial Cost - $/Hp Simple &

More information

Introduction. Upon completion of AC Motors you should be able to: Explain the concepts of force, inertia, speed, and torque

Introduction. Upon completion of AC Motors you should be able to: Explain the concepts of force, inertia, speed, and torque Table of Contents Introduction...2 AC Motors...4 Force and Motion...6 Energy... 11 Electrical Energy... 13 AC Motor Construction... 17 Magnetism... 23 Electromagnetism... 25 Developing a Rotating Magnetic

More information

ECE 325 Electric Energy System Components 6 Three Phase Induction Motors. Instructor: Kai Sun Fall 2016

ECE 325 Electric Energy System Components 6 Three Phase Induction Motors. Instructor: Kai Sun Fall 2016 ECE 325 Electric Energy System Components 6 Three Phase Induction Motors Instructor: Kai Sun Fall 2016 1 Content (Materials are from Chapters 13-15) Components and basic principles Selection and application

More information

ADS7 AC Contactor Starters

ADS7 AC Contactor Starters ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice

More information

Understand how soft starters operate.

Understand how soft starters operate. Exercise 5-2 Soft Starters EXERCISE OBJECTIVE Understand how soft starters operate. DISCUSSION Soft starters are solid-state devices providing gradual voltage increase, for the purpose of starting a motor

More information

Contents. Review of Electric Circuitd. Preface ;

Contents. Review of Electric Circuitd. Preface ; Preface ; Chapter 1 Review of Electric Circuitd 1.1 Introduction, 1 1.2 Direct Circuit Current, 1 1.2.1 Voltage, 3 1.2.2 Power, 3 1.2.3 Ohm's Law, 5 1.2.4 KirchhofTs Laws, 5 1.2.4.1 Kirchhoff s Current

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Understanding NEMA Motor Nameplates

Understanding NEMA Motor Nameplates Understanding NEMA Motor Nameplates Mission Statement is to be the best (as determined by our customers) marketers, designers and manufacturers of industrial electric motors, mechanical power transmission

More information

A Novel Technique for Energy & Cost Effective Drives for AC & DC Motors

A Novel Technique for Energy & Cost Effective Drives for AC & DC Motors International Journal of Electrical Engineering. ISSN 0974-2158 Volume 3, Number 3 (2010), pp. 241--250 International Research Publication House http://www.irphouse.com A Novel Technique for Energy & Cost

More information

HCM634K - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCM634K - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet - Winding 311 and 312 Technical Data Sheet SPECIFICATIONS & OPTIONS WINDING 311 and 312 STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

AUCOM WHITE PAPER SERIES GET YOUR MOTOR RUNNING. An introduction to reduced voltage starting of three phase induction motors

AUCOM WHITE PAPER SERIES GET YOUR MOTOR RUNNING. An introduction to reduced voltage starting of three phase induction motors AUCOM WHITE PAPER SERIES GET YOUR MOTOR RUNNING An introduction to reduced voltage starting of three phase induction motors GET YOUR MOTOR RUNNING WHITE PAPER #1 Reduced voltage starting of three phase

More information

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition) Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition) 1. Which drawing type shows physical details as seen by the eye? 2. Which drawing is similar to a pictorial drawing but has

More information

HCI634H - Winding 311 and 312. Technical Data Sheet

HCI634H - Winding 311 and 312. Technical Data Sheet HCI634H - Winding 311 and 312 Technical Data Sheet HCI634H SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

HCI634G - Technical Data Sheet

HCI634G - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

Handout Activity: HA773

Handout Activity: HA773 Charging system HA773-2 Handout Activity: HA773 Charging system The charging system allows for a means to recharge the battery and allow for electrical usage of components in the vehicle. The charging

More information

Stator rheostat, Autotransformer Star to Delta starter and rotor resistance starter.

Stator rheostat, Autotransformer Star to Delta starter and rotor resistance starter. UNIT-IV 1.What are the types of starters? Stator rheostat, Autotransformer Star to Delta starter and rotor resistance starter. 2. List out the methods of speed control of cage type 3-phase induction motor?

More information

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet HCI634J - Winding 311 and 312 Technical Data Sheet HCI634J SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

HCI634H - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634H - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet HCI634H - Winding 311 and 312 Technical Data Sheet HCI634H SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

Jogging and Plugging of AC and DC Motors. Prepared by Engr. John Paul Timola, LPT

Jogging and Plugging of AC and DC Motors. Prepared by Engr. John Paul Timola, LPT Jogging and Plugging of AC and DC Motors Prepared by Engr. John Paul Timola, LPT Jogging sometimes called inching momentary operation of a motor for the purpose of accomplishing small movements of the

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

CT430 - Soft Starters on Motor Applications

CT430 - Soft Starters on Motor Applications CT430 - Soft Starters on Motor Applications Bill Bernhardt Sr. Commercial Engineer May 16, 2018 PUBLIC Copyright 2018 Rockwell Automation, Inc. All Rights Reserved. 1 Topics Traditional Motor Starting

More information

Fall 1997 EE361: MIDTERM EXAM 2. This exam is open book and closed notes. Be sure to show all work clearly.

Fall 1997 EE361: MIDTERM EXAM 2. This exam is open book and closed notes. Be sure to show all work clearly. NAME: STUDENT NUMBER: Fall 1997 EE361: MIDTERM EXAM 2 This exam is open book and closed notes. Be sure to show all work clearly. 1. 10 points - Mechanical and Electrical Energy Relationships: A dc motor

More information

When to use a Soft Starter or an AC Variable Frequency Drive

When to use a Soft Starter or an AC Variable Frequency Drive White Paper When to use a or an AC Variable Frequency Product lines: Smart Motor Controllers (SMCs), AC Variable Frequency s (VFDs) Topic Page Introduction 2 Starting Methods 3 How does a VFD work? 7 Comparisons

More information

(d) None of the above.

(d) None of the above. Dr. Mahalingam College of Engineering and Technology, Pollachi-3 (An Autonomous Institution affiliated to Anna niversity) CCET II (2016 Regulation) Name of Programme: B.E. (EEE) Course Code & Course Title:

More information

SYNCHRONIZER. The ABC s of Synchronous Motors 200-SYN-42

SYNCHRONIZER. The ABC s of Synchronous Motors 200-SYN-42 SYNCHRONIZER The ABC s of Synchronous Motors 200-SYN-42 SYNCHRONOUS 2 The ABC s of Synchronous Motors The Greeks had a word for it SYNCHRONOUS syn a prefix meaning with, and chronos a word denoting time.

More information

A few tips on how to select contactor for use in direct on line starter

A few tips on how to select contactor for use in direct on line starter electrical-engineering-portal.com http://electrical-engineering-portal.com/contactors-direct-on-line-starters A few tips on how to select contactors for use in direct on line starters Google+ A few tips

More information

Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please

Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please click the Notes button in the bottom right corner. 1 After

More information

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection,

More information

Institute of Technology, Nirma University B. Tech. Sem. V: Electrical Engineering 2EE305: ELECTRICAL MACHINES II. Handout: AC Commutator Motors

Institute of Technology, Nirma University B. Tech. Sem. V: Electrical Engineering 2EE305: ELECTRICAL MACHINES II. Handout: AC Commutator Motors Institute of Technology, Nirma University B. Tech. Sem. V: Electrical Engineering 2EE305: ELECTRICAL MACHINES II Handout: AC Commutator Motors Prepared by: Prof. T. H. Panchal Learning Objective: Introduction

More information

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M] Code No:RT32026 R13 SET - 1 III B. Tech II Semester Regular Examinations, April - 2016 POWER SEMICONDUCTOR DRIVES (Electrical and Electronics Engineering) Time: 3 hours Maximum Marks: 70 Note: 1. Question

More information

Intelligent Softstarter Controllers

Intelligent Softstarter Controllers Intelligent Softstarter Controllers General escription... 2 Custom Softstarter Panels... 4 Series PCS Controllers... 6 Selection Guide... 8 Accessories... 19 Replacement Parts... 21 Technical Information

More information

AND LOAD PARAMETERS IMPORTANT MOTOR. Torque x Speed Constant. Horsepower= Mechanical Power Rating Expressed in either horsepower or watts

AND LOAD PARAMETERS IMPORTANT MOTOR. Torque x Speed Constant. Horsepower= Mechanical Power Rating Expressed in either horsepower or watts MOTOR SELECTION Electric motors should be selected to satisfy the requirements of the machines on which they are applied without exceeding rated electric motor temperature IMPORTANT MOTOR AND LOAD PARAMETERS

More information

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters .2 Type S80+, Soft Starters Contents Description Type S6, Solid-State Soft Starters........... Type S80+, Soft Starters Operation............................. Features.............................. Benefits...............................

More information

Synchronous Generators I. Spring 2013

Synchronous Generators I. Spring 2013 Synchronous Generators I Spring 2013 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is then turned

More information

Technical Guide No. 7. Dimensioning of a Drive system

Technical Guide No. 7. Dimensioning of a Drive system Technical Guide No. 7 Dimensioning of a Drive system 2 Technical Guide No.7 - Dimensioning of a Drive system Contents 1. Introduction... 5 2. Drive system... 6 3. General description of a dimensioning

More information

ECET 211 Electric Machines & Controls Lecture 2-3 (Part 3 of 3) Symbols and Drawing for Electric Motor Control Systems

ECET 211 Electric Machines & Controls Lecture 2-3 (Part 3 of 3) Symbols and Drawing for Electric Motor Control Systems ECET 211 Electric Machines & Controls Lecture 2-3 (Part 3 of 3) Symbols and Drawing for Electric Motor Control Systems Text Book: Chapter 2. Understanding Electrical Drawings, Electric Motors and Control

More information

Chapter 3.10: Energy Efficient Technologies in Electrical Systems

Chapter 3.10: Energy Efficient Technologies in Electrical Systems Chapter 3.10: Energy Efficient Technologies in Electrical Systems Part-I: Objective type questions and answers 1. Maximum demand controller is used to. a) switch off essential loads in a logical sequence

More information

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet - Winding 311 and 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

Single Phase Induction Motors

Single Phase Induction Motors Single Phase Induction Motors Prof. T. H. Panchal Asst. Professor Department of Electrical Engineering Institute of Technology Nirma University, Ahmedabad Introduction As the name suggests, these motors

More information

2014 ELECTRICAL TECHNOLOGY

2014 ELECTRICAL TECHNOLOGY SET - 1 II B. Tech I Semester Regular Examinations, March 2014 ELECTRICAL TECHNOLOGY (Com. to ECE, EIE, BME) Time: 3 hours Max. Marks: 75 Answer any FIVE Questions All Questions carry Equal Marks ~~~~~~~~~~~~~~~~~~~~~~~~~~

More information

HCI 534E/544E - Technical Data Sheet

HCI 534E/544E - Technical Data Sheet HCI 34E/44E - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

HCI 434E/444E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet HCI 434E/444E - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

HCI634H - Technical Data Sheet

HCI634H - Technical Data Sheet HCI634H - Technical Data Sheet HCI634H SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1 Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT - Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2 FAN ENGINEERING Information and Recommendations for the Engineer Twin City Fan FE-1800 Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia Introduction Bringing a fan up to speed

More information

Scheme - I. Sample Question Paper

Scheme - I. Sample Question Paper Program Name Program Code Course Title Sample Question Paper : Diploma in Industrial Electronics : IE : Electrical Machines and Transformers Max. Marks : 70 Time : 3 Hrs. Q1. ATTEMPT ANY FIVE OF THE FOLLOWING.

More information