ELITE Series R-410A - Upflow / Horizontal

Size: px
Start display at page:

Download "ELITE Series R-410A - Upflow / Horizontal"

Transcription

1 PRODUCT SPECIFICATIONS AIR HANDLERS CBX7UH ELITE Series R-0A - Upflow / Horizontal Bulletin No. 08 March 0 Supersedes October 0 Nominal Capacity -. to Tons Optional Electric Heat -. to kw MODEL NUMBER IDENTIFICATION CB X 7 UH Unit Type CB = Air Handler Refrigerant Type X = R-0A Series Configuration UH = Upflow/Horizontal Nominal Cooling Capacity - Tons 08 =. tons 0 = tons 00 =. tons 06 = tons 0 =. tons 08 = tons 060 = tons Minor Revision Number Refrigerant Metering Device = Fixed Orifice = TXV - Bleedport (indoor unit) = TXV - Non-bleedport (indoor unit) = TXV - Non-bleedport (outdoor unit) 6 = TXV - R-0A Non-bleedport (indoor unit) Voltage 0 = 08/0V- phase-60hz 60 = 60V- phase-60hz Can be used with 7V (step-down transformer required)

2 FEATURES CONTENTS Blower Data... 8 Dimensions... Electrical Data... 6 Electric Heat Data... 0 Features... Installation Clearances With Electric Heat... Model Number Identification... Optional Accessories... 6 Replacement Breakers... 9 Specifications... 6 F H B E G WARRANTY All covered components - five years in residential applications, one year in non-residential applications Refer to Lennox Limited Warranty Certificate included with each unit for additional details. APPROVALS Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in accordance with AHRI Standard 0/0. Optional electric heaters are rated in accordance with US Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations. Blower performance data according to unit tests conducted in Lennox air test chamber. Air handlers are UL Listed to US and Canadian safety standards and components within are bonded for grounding to meet safety standards for servicing required by CEC and NEC. Air handler units are approved for installation in manufactured housing and mobile homes. ISO 900 Registered Manufacturing Quality System. APPLICATIONS. to ton nominal sizes. Upflow or horizontal applications. Downflow applications with optional conversion kit. Applicable to expansion valve systems in cooling applications and check and expansion valve systems in heat pump applications. Wide-range check and expansion valve is factory installed. See bulletins in section Air Conditioners for cooling capacities. See bulletins in section Heat Pump Outdoor Units for cooling and heating capacities. Optional field installed electric heaters available in several sizes for additive heating capacity. CBX7UH / Page B C D I D REFRIGERANT SYSTEM C Copper Tube/Enhanced Fin Indoor Coil Lennox designed and fabricated twin coils. Assembled in A configuration. Provides extra large surface and contact area, excellent heat transfer and low air resistance for maximum efficiency. Precise circuiting for uniform refrigerant distribution. Precisely spaced ripple-edged aluminum fins fitted to durable seamless copper tubes. Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area. Lanced fins provide maximum exposure of fin surface to air stream. Long life copper tubing is easy to service. Rifled tubing provides superior heat transfer. Flared shoulder tubing joints and silver soldering provide tight, leakproof joints. Coil thoroughly factory tested under high pressure to ensure leakproof construction. Refrigerant Line Connections Suction (vapor) and liquid lines have sweat connections that extended outside of the cabinet for ease of connection. See dimension drawings for locations. Check and Expansion Valve Furnished For use with R-0A systems. Wide range valve with Chatleff style fitting. Factory installed on all models, internal to cabinet.

3 E F G FEATURES BLOWER Programmable Multi-Speed Blower Motor Programmable high efficiency multi-speed blower motor. By maintaining constant torque output, blower motor can deliver more uniform (but not constant) airflow over the static pressure range. Programmable multi-speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Leadless blower motor features simple plug-in connections. Choice of blower speeds is available. See Blower Data tables. Blower speed change is easily accomplished by a simple wiring change. Blower Assembly Lennox designed and built, direct drive blower. Each blower is statically and dynamically balanced as an assembly before installation in the unit. Blower motor is resiliently mounted to blower assembly. Blower slides out of cabinet for servicing. CABINET Constructed of heavy-gauge galvanized steel. Completely insulated with thick fiberglass insulation. Pre-painted steel cabinets have mildly textured enamel finish with primer coat on unpainted side of all panels. Units are shipped in one piece but may be disassembled into two separate sections for ease of installation in tight applications. See dimension drawings. Thick rubber gasket between sections of the two piece cabinets provides an air tight seal. No external screw heads on sides of cabinet for tight installations without damage to walls or woodwork. Removable panels provide complete service access. Electrical inlets provided in sides and top of cabinet. See dimension drawings for locations. Dual Position Drain Pans Drain pans designed for upflow, downflow or horizontal applications. Deep, corrosion resistant plastic drain pans have dual pipe drains. See dimension drawings. Optional Accessories Downflow Combustible Flooring Floor Base Base is required for models with electric heat installed in downflow position on combustible floors. Downflow Conversion Kit Required for field conversion to downflow position. Kit consists of drip shields and brackets for repositioning coil and drain pan. See Specifications table. Horizontal Support Frame Kit Provides support of unit in horizontal applications. Consists of () x -/ x -/8 in. and () x x -7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. Bolts and nuts furnished for field assembly. Suspending rods must be field provided. Side Return Unit Stand (Upflow Only) Raises unit 6 in. above floor for side return air duct connection. Eliminates need for wooden platform construction. All aluminum construction. Two adjustable frames fit -08/0 thru -060 models. Wall Hanging Bracket Kit (Upflow Only) Allows unit to be hung on wall at any height. Consists of heavy-gauge steel support brackets (one for air handler, one for wall mount). Screws furnished for fastening one bracket to unit. Bolts for fastening one bracket to wall are field provided. Low Leakage Cabinet All models have less than % air leakage and meet ANSI/ASHRAE Standard 9-00 Method of Test for Determining the Air Tightness of HVAC Equipment. Upflow/Horizontal Capability (Optional Downflow) Shipped for upflow and horizontal left-hand discharge. May be field converted to horizontal right-hand air discharge by repositioning horizontal drain pan. Optional downflow kit available for field conversion. CBX7UH / Page

4 FEATURES CONTROLS Transformer and Blower Cooling Relay volt transformer with in-line fuse and blower cooling relay furnished as standard. Factory installed in the unit control box. Terminal strip furnished. Optional Accessories ComfortSense 7000 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, HOME SCHEDULE OPTIONS touchscreen thermostat. SET AT Heat/ Cool. Auto-changeover. Controls humidity during cooling mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. Remote outdoor temperature sensor (optional) allows the thermostat to display outdoor temperature. Required in dual fuel and Humiditrol applications. See the ComfortSense 7000 Product Specifications bulletin in the Controls section for more information. Dehumidification Relay Kit Required with ComfortSense thermostat. Provides dehumidification mode when used in conjunction with ComfortSense 7000 thermostat. Used with single- or two-stage heat pumps and air conditioners. Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. CBX7UH / Page MODE SCHED AUTO ON INDOOR RH 6% WED AN :AM HEAT SET AT COOL H OPTIONAL ELECTRIC HEAT Field install internal to unit cabinet. Available in several voltages and kw sizes. See Electric Heat tables. Helix wound nichrome heating elements exposed directly in air stream resulting in instant heat transfer, low element temperatures and long service life. Each element equipped with accurately located limit control with fixed temperature off setting and automatic reset. Supplemental thermal cutoff limit control, provides positive protection in case of excessive temperatures. Thermal sequencer relay brings elements on and off line, in sequence and equal increments, with time delay between each. Initiates and terminates blower operation. Heating control relay(s) furnished as standard. Control box and access cover constructed of heavy gauge galvanized steel. Factory assembled with controls installed and wired. Electric heat low voltage controls plug-in to air handler. Breaker Models ECB9-CB, -CB, -6CB, -8CB, -9CB, -0CB, -.CB, -CB, -0CB, -CB and -0CB (08/0V-ph) and ECB9-CB, -0CB and -CB (08/0V-ph) heaters are equipped with circuit breakers for overload and short circuit protection. Factory wired and mounted on electric heat unit. Current sensitive and temperature actuated. Manual reset. breakers qualify as disconnect means at unit in many areas, eliminate the need for field provided disconnect. Consult local electrical code in your area. NOTE - 60V- phase air handlers can be used in 7V applications. 7V electric heaters are shipped with a 7V to 60V step-down transformer. Optional Accessories Breaker Cover Kit Flexible plastic cover protects circuit breaker. Recommended in areas with high humidity or unconditioned areas to prevent nuisance tripping. Single-Point Power Source Control Box Control Box may be used with optional electric heat when single power supply is connected to multi-circuit electric heat. Field installs external to the unit cabinet on either side or top. Constructed of heavy gauge steel, baked enamel finish, prepunched mounting holes, electrical inlet knockouts, and terminal strip. Removable cover provides easy access. Dimensions (H x W x D) - 7 x 7 x in.

5 I FEATURES INDOOR AIR QUALITY Air Filter Tool-less access to filter area for quick and easy servicing. Disposable frame type filter furnished and factory installed in rails in cabinet. See Specifications tables for sizes. Optional Accessories Healthy Climate Germicidal UVC Light Germicidal lamp emits C-Band ultra-violet (UVC) energy at.7 nanometers, which is proven to be effective in reducing microbes such as viruses, bacteria, yeasts, and molds. This process either destroys the organism or controls its ability to reproduce. UVC germicidal light greatly reduces the growth and proliferation of mold and other bioaerosols (bacteria and viruses) on illuminated surfaces (particularly coil and drain pan). Surfaces must be cleaned prior to UVC light being installed. Available in volt and 0.0V-ph models. Air handlers have a factory provided knockout in the coil delta plate for mounting light within coil area. Shielding baffle is required when installing light above a non-uvc resistant component, such as a filter. Baffle must be ordered separately. INSTALLATION CLEARANCES WITH ELECTRIC HEAT Cabinet 0 inch (0 mm) To Plenum inch ( mm) To Outlet Duct within feet (9 mm) inch ( mm) Floor See Note # Service / Maintenance See Note # Units installed on combustible floors in the downflow position with electric heat require optional downflow combustible flooring base. Front service access - inches (60 mm) minimum. NOTE - If cabinet depth is more than inches (60 mm), allow a minimum of the cabinet depth plus inches ( mm). CBX7UH / Page

6 SPECIFICATIONS General Data Model Number CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 Nominal tonnage.. Connections Suction (vapor) line (o.d.) - in. sweat / / / / Liquid line (o.d.) - in. sweat /8 /8 /8 /8 Condensate - in. fpt () / () / () / () / Indoor Coil Net face area - ft Tube outside diameter - in. /8 /8 /8 /8 Number of rows Fins per inch Blower Wheel nominal diameter x width - in. 0 x 8 0 x 8 x 8 x 8 Blower motor output - hp / / / / Filters Size of filter - in. 0 x 0 x 0 x 0 x 0 x 0 x 0 x 0 x Shipping Data - package - lbs ELECTRICAL DATA Voltage - phase - 60hz 08/0V-ph 08/0V-ph 08/0V-ph 08/0V-ph Voltage - phase - 60hz V-ph overcurrent protection (unit only) - All voltages circuit ampacity (unit only) - 08/0V Blower Motor Full Load Amps - 08/0V.... circuit ampacity (unit only) - 60V Blower Motor Full Load Amps - 60V OPTIONAL ACCESSORIES - ORDER SEPARATELY ComfortSense 7000 Thermostat Y08 Y08 Y08 Y08 Remote Outdoor Temperature Sensor (for ComfortSense 7000) X68 X68 X68 X68 Dehumidification Relay Kit 6W6 6W6 6W6 6W6 Downflow Combustible Flooring Base K K K K Downflow Conversion Kit 8M7 8M7 8M7 8M7 Electric Heat - See Electric Heat Data tables. to 0 kw Electric Heat Breaker Cover Kit 8W0 8W0 8W0 8W0 Healthy Climate Germicidal Light UVC-V (V) X9 X9 X9 X9 Shielding Baffle (required) Y0 Y0 Y0 Y0 UVC-W-S (0/0v- ph) X9 X9 X9 X9 Shielding Baffle (required) X9900 X9900 X9900 X9900 Horizontal Support Frame Kit 6J8 6J8 6J8 6J8 Side Return Unit Stand (Upflow Only) K K K K Single Point Power Source Control Box H9 H9 H9 H9 Wall Hanging Bracket Kit (Upflow Only) K0 K0 K0 K0 Disposable frame type filter. HACR type circuit breaker or fuse. Blower motor is 60V - phase. Optional electric heat is 60V - phase. CBX7UH / Page 6

7 SPECIFICATIONS General Data Model Number CBX7UH-0 CBX7UH-08 CBX7UH-060 Nominal tonnage. Connections Suction (vapor) line (o.d.) - in. sweat 7/8 7/8 7/8 Liquid line (o.d.) - in. sweat /8 /8 /8 Condensate - in. fpt () / () / () / Indoor Coil Net face area - ft Tube outside diameter - in. /8 /8 /8 Number of rows Fins per inch Blower Wheel nominal diameter x width - in. x 9 x 9 x 9 Blower motor output - hp Filters Size of filter - in. 0 x x 0 x x 0 x x Shipping Data - package lbs ELECTRICAL DATA Voltage - phase - 60hz 08/0V-ph 08/0V- ph 08/0V- ph Voltage - phase - 60hz V-ph 60V-ph overcurrent protection (unit only) - All voltages circuit ampacity (unit only) - 08/0V Blower Motor Full Load Amps - 08/0V circuit ampacity (unit only) - 60V Blower Motor Full Load Amps - 60V OPTIONAL ACCESSORIES - ORDER SEPARATELY ComfortSense 7000 Thermostat Y08 Y08 Y08 Remote Outdoor Temperature Sensor (for ComfortSense 7000) X68 X68 X68 Dehumidification Relay Kit 6W6 6W6 6W6 Downflow Combustible Flooring Base K K K Downflow Conversion Kit 8M7 8M7 8M7 Electric Heat - See Electric Heat Data tables to kw Electric Heat Breaker Cover Kit 8W0 8W0 8W0 Healthy Climate Germicidal Light UVC-V (V) X9 X9 X9 Shielding Baffle (required) Y0 Y0 Y0 UVC-W-S (0/0v- ph) X9 X9 X9 Shielding Baffle (required) X9900 X9900 X9900 Horizontal Support Frame Kit 6J8 6J8 6J8 Side Return Unit Stand (Upflow Only) K K K Single Point Power Source Control Box H9 H9 H9 Wall Hanging Bracket Kit (Upflow Only) K0 K0 K0 Disposable frame type filter. HACR type circuit breaker or fuse. Blower motor is 60V - phase. Optional electric heat is 60V - phase. CBX7UH / Page 7

8 BLOWER DATA CBX7UH-08 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts N/A N/A N/A N/A N/A N/A N/A N/A CBX7UH-0 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts N/A N/A N/A N/A N/A N/A N/A N/A CBX7UH-00 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts N/A N/A N/A N/A N/A N/A N/A N/A CBX7UH-06 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V / 60V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts CBX7UH / Page 8

9 BLOWER DATA CBX7UH-0 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts N/A N/A N/A N/A N/A N/A N/A N/A CBX7UH-08 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V / 60V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts N/A N/A N/A N/A N/A N/A N/A N/A CBX7UH-060 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V / 60V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts N/A N/A N/A N/A N/A N/A N/A N/A REPLACEMENT CIRCUIT BREAKERS Voltage Description Catalog No. amp, pole K 0 amp, pole 7K70 amp, pole 7K07 08/0V - Phase 0 amp, pole 9K amp, pole 7K7 0 amp, pole K 60 amp, pole 7K7 0 amp, pole 6W7 amp, pole K 08/0V - Phase 0 amp, pole K6 amp, pole 8M86 0 amp, pole K 60 amp, pole K7 CBX7UH / Page 9

10 ELECTRIC HEAT DATA - CBX7UH-08 Model Number No. of Stages Input Volts kw Btuh Blower Motor Full Load Amps SINGLE PHASE. kw lbs. kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs. ECB9-. (L7) ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-0 (L) ECB9-0CB (L) 60A breaker , , , , ,0. 0., , , , , , , , , , , , , , , , , , , , , , , NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page 0

11 ELECTRIC HEAT DATA - CBX7UH-0 Model Number No. of Stages Input Volts kw Btuh Blower Motor Full Load Amps SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs. ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-0 (L) ECB9-0CB (L) 60A breaker ,0. 0., , , , , , , , , , , , , , , , , , , , , , , NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

12 ELECTRIC HEAT DATA - CBX7UH-00 Model Number SINGLE PHASE kw ECB9- (L0) lbs. ECB9-CB (L) 0A breaker kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs.. kw 0 lbs. kw lbs. THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker 60A breaker ECB9-0 (L) ECB9-0CB (L) 60A breaker ECB9-.CB (L) () A breaker & () 0A breaker ECB9-CB (L6) () 0A breaker & () 60A Breaker ECB9-8 (L6) ECB9-0 (L6) ECB9-CB (L6) () 0A breaker No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

13 ELECTRIC HEAT DATA - CBX7UH-06 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-0 (L) ECB9-0CB (L) 60A breaker ECB9-.CB (L) () A breaker and () 0A breaker ECB9-CB (L6) () 0A breaker and () 60A Breaker ECB9-0CB (L8) () 0A breaker and () 60A Breaker No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

14 ELECTRIC HEAT DATA - CBX7UH-06 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. Model Number ECB9-8 (L6) ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) () 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

15 ELECTRIC HEAT DATA - CBX7UH-0 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. No. Volts kw Model Number of Input Input Stages ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker 60A breaker ECB9-.CB (L) () A breaker and () 0A breaker ECB9-CB (L6) () 0A breaker and () 60A breaker ECB9-0CB (L8) () 0A breaker and () 60A breaker ECB9-CB (L9) () 0A breakers Btuh Input Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

16 ELECTRIC HEAT DATA - CBX7UH-0 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9-8 (L6) Terminal block ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker ECB9-0 (8K9) () A Fuses 6 ECB9-0 (8K) () A Fuses ECB9-CB (L6) () A breaker ECB9- (8K0) () 0A Fuses 6 ECB9- (8K) () A Fuses No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. 6 Blower motor is rated at 60V. CBX7UH / Page 6

17 ELECTRIC HEAT DATA - CBX7UH-08 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-.CB (L) (9K68) () A breaker & () 0A breaker ECB9-CB (L6) () 0A breaker & () 60A breaker ECB9-0CB (L8) () 0A breaker & () 60A breaker ECB9-CB (L9) () 0A breakers No. of Stages Input Blower Motor Full Load Amps NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Volts kw Btuh Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page 7

18 ELECTRIC HEAT DATA - CBX7UH-08 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9-8 (L6) Terminal block ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker ECB9-0 (8K9) () A Fuses 6 ECB9-0 (8K) () A Fuses ECB9-CB (L6) () A breaker ECB9- (8K0) () 0A Fuses 6 ECB9- (8K) () A Fuses No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. 6 Blower motor is rated at 60V. CBX7UH / Page 8

19 ELECTRIC HEAT DATA - CBX7UH-060 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-.CB (L) () A Breaker and () 0A breaker No. of Stages Input Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , kw lbs. 0 kw 9 lbs. ECB9-CB (L6) () 0A breaker and () 60A breaker ECB9-0CB (L8) () 0A Breaker and () 60A breaker 08. 8, , , , , , , , kw 9 lbs. ECB9-CB (L9) () 0A breakers NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page 9

20 ELECTRIC HEAT DATA - CBX7UH-060 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9-8 (L6) Terminal block ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker ECB9-0 (8K9) () A Fuses 6 ECB9-0 (8K) () A Fuses ECB9-CB (L6) () A breaker ECB9- (8K0) () 0A Fuses 6 ECB9- (8K) () A Fuses No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. 6 Blower motor is rated at 60V. CBX7UH / Page 0

21 DIMENSIONS - INCHES (MM) UPFLOW POSITION / (9) / (9) -/6 (8) D LINE VOLTAGE INLETS (Top and Left Side) TOP VIEW B SUPPLY AIR OPENING / (9) LOW VOLTAGE INLETS (Top and Right Side) /8 (6) -/8 (9) SUCTION LINE () -/8 (7) LIQUID LINE C -/ (70) DETAIL OF PIPING PLATE -/ () -/8 () -/ (89) CONDENSATE DRAINS () (Horizontal) CONDENSATE DRAINS () (Upflow and Downflow) AIR FLOW G OPTIONAL ELECTRIC HEAT (Field Installed) BLOWER Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. A PIPING PLATE H SUCTION LINE COIL LIQUID LINE /8 (6) Return Air F FRONT VIEW /8 (6) FILTER ACCESS FILTER () Return Air E SIDE VIEW /8 (6) Model No. A B C D E F G H CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 CBX7UH-0 CBX7UH-08 CBX7UH-060 in. 9-/ -/ 0-/8 9-/ 9 0 -/8 -/8 mm in. -/ -/8 9-/ 0 6-/8 -/8 mm in. 8-/ -/ -/8 9-/ 0 7-7/8 0-/8 mm in. 6-/ -/ -/8 9-/ 0 7-7/8 -/8 mm CBX7UH / Page

22 DIMENSIONS - INCHES (MM) DOWNFLOW POSITION with Optional Downflow Conversion Kit (Required) DETAIL OF PIPING PLATE /8 (6) E /8 (6) F RETURN AIR OPENING /8 (6) -/8 (9) SUCTION LINE () /8 (9) LIQUID LINE -/8 () CONDENSATE DRAINS () (Horizontal) CONDENSATE DRAINS () (Up-Flow and Downflow) () TOP VIEW () -/ () -/ (89) B FILTER ACCESS C FILTER H PIPING PLATE SUCTION LINE COIL LIQUID LINE AIR FLOW G A OPTIONAL ELECTRIC HEAT (Field Installed) LOW VOLTAGE (Right Side) LINE VOLTAGE (Left Side) BLOWER / (9) Supply Air D FRONT VIEW / (9) /8 (6) Supply Air -/6 (8) SIDE VIEW /8 (6) Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. Model No. A B C D E F G H CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 CBX7UH-0 CBX7UH-08 CBX7UH-060 in. 9-/ -/ 0-/8 9-/ 9 0 -/8 -/8 mm in. -/ -/8 9-/ 0 6-/8 -/8 mm in. 8-/ -/ -/8 9-/ 0 7-7/8 0-/8 mm in. 6-/ -/ -/8 9-/ 0 7-7/8 -/8 mm CBX7UH / Page

23 DIMENSIONS - INCHES (MM) DETAIL OF PIPING PLATE RIGHT-HAND AIR DISCHARGE -/8 (7) () LIQUID LINE FILTER SUCTION LINE -/ (6) CONDENSATE DRAINS () (Upflow and Downflow) /8 (6) -/ () -/ (8) -/8 (9) -/8 () CONDENSATE DRAINS () (Horizontal) LIQUID LINE COIL SUCTION LINE H TOP VIEW A BLOWER OPTIONAL ELECTRIC HEAT (Field Installed) G C Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. /8 (6) LINE VOLTAGE INLETS (Top and Right Side) -/6 (8) / (9) / (9) E /8 (6) F RETURN AIR OPENING () PIPING PLATE AIR FLOW B SUPPLY AIR OPENING D /8 (6) END VIEW FILTER ACCESS FRONT VIEW LOW VOLTAGE INLETS (Bottom and Right Side) END VIEW / (9) LEFT-HAND AIR DISCHARGE FILTER DETAIL OF PIPING PLATE C BLOWER COIL -/8 () Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. OPTIONAL ELECTRIC HEAT (Field Installed) TOP VIEW SUCTION LINE LIQUID LINE -/8 (9) SUCTION LINE LIQUID LINE () -/8 (7) / (9) / (9) -/6 (8) LOW VOLTAGE INLETS (Top and Left Side) /8 (6) G A H /8 (6) D SUPPLY AIR OPENING B AIR FLOW PIPING PLATE FILTER ACCESS CONDENSATE DRAINS () (Horizontal) () E RETURN AIR OPENING F /8 (6) / (9) END VIEW LINE VOLTAGE INLETS (Bottom and Left Side) FRONT VIEW -/ () -/ (6) -/ (8) /8 (6) END VIEW Model No. CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 CBX7UH-0 CBX7UH-08 A B C D E F G H inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm 9-/ -/ 0 0-/8 9-/ /8 6 -/ / 0 -/8 7 9-/ / /8 6 8-/ 86 -/ 0 -/8 6 9-/ / /8 778 CBX7UH / 88 -/ 0 -/8 6 9-/ / /8 879 CBX7UH / Page

24 DIMENSIONS - INCHES (MM) AIR FLOW PIPING PLATE AIR FLOW B B AIR FLOW PIPING PLATE A /8 (6) RIGHT-HAND AIR FLOW B /8 (6) /8 (6) A LEFT-HAND AIR FLOW B AIR FLOW PIPING PLATE A Model No. CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 CBX7UH-0 CBX7UH-08 A B in. mm in. mm 9-/ -/ 0 9 -/ 0 8-/ 86 -/ 0 CBX7UH / 88 -/ 0 PIPING PLATE AIR FLOW A UPFLOW DOWNFLOW /8 (6) SIDE RETURN UNIT STAND (Upflow Only) 6 (06) 6 () -/ (0) ADJUSTABLE 0 (08) to (6) ALL UNITS CBX7UH / Page

25 DIMENSIONS - INCHES (MM) DOWNFLOW COMBUSTIBLE FLOORING BASE AIR HANDLER DOWNFLOW COMBUSTIBLE FLOORING BASE Catalog No. K -/8 () -/8 () 0 (08) TOP VIEW -/8 (89) / (9) Break off extended width at pre-perforated line to fit specific air handler application. NOTE - Width of base includes an additional in. ( mm) for air handler positioning adjustment. -/8 () SUPPLY AIR OPENING /8 (6) -/ () Opening SIDE VIEW (76) A B C D No modification required. Model No. 08, 0 00, 06 0, 08, 060 in. mm in. mm in. mm A -/ B / C /8 676 CBX7UH / Page

26

27

28 REVISIONS Sections Electric Heat Data Description of Change New catalog numbers for electric heat models. Removed EvenHeater electric heat models. Visit us at For the latest technical information, Contact us at LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 0 Lennox Industries, Inc.

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

MERIT Series R-410A - Upflow / Horizontal - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0

More information

DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower E N G I N E E R I N G D A T A A I R H A N D L E R S C31MV DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable lower ulletin No. 210107 July 2007 Supersedes January 2007 Nominal Capacity 3 to 5 Tons

More information

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A E N G I N E E R I N G D T I R H N D L E R S CB29M Multi Position 60 HZ Bulletin No. 210478 November 2008 Supersedes July 2007 3 to 5 Tons Optional Electric Heat 5 to 30 kw MODEL NUMBER IDENTIFICTION CB

More information

Typical Applications. Horizontal Installation

Typical Applications. Horizontal Installation ENGINEERING DATA COILS COIL UNITS CB19 AND CBH19 SERIES UP-FLOW, DOWN-FLOW AND HORIZONTAL COIL UNITS *12,600 to 65,500 Btuh (3.7 to 19.2 kw) Cooling Capacity 11,500 to 60,000 Btuh (3.4 to 17.6 kw) Heat

More information

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS CX34 PRODUCT SPECIFICATIONS Upflow - Cased - R-410A Bulletin No. 210322 August 2011 Supersedes August 2010 MODEL NUMBER IDENTIFICATION 18/24 = 1.5/2 tons 30 = 2.5 tons 31 = 2.5 tons 36 = 3

More information

T A A 120 S 4 D - 1 M

T A A 120 S 4 D - 1 M PRODUCT SPECIFICATIONS AIR HANDLERS TA T-CLASS SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 50 HZ Bulletin No. 490133 February 2013 Supersedes December 2010 180-240 Models 072-090-120-150 Models Noal

More information

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT Service Literature Corp. 9711 L7 CB29M CB30M ELITE 10 CB29M and ELITE 12 CB30M SERIES UNITS INCLUDING ECB29 The Elite 10 CB29M and Elite 12 CB30M are high efficiency blower coils. Several models are available

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage

More information

T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ

T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ PRODUCT SPECIFICATIONS AIR HANDLERS TA T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ Bulletin No. TAA-07-40 (05/015) 180-40 Models 07-090-10-150 Models Nominal Capacity - 6 to 0 Tons Optional

More information

Air Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011)

Air Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011) Air Handlers ACBX32CM 3 Phase Multi-Position ACBX32CM-100 (07/2011) FEATURES AND BENEFITS Application Environmentally friendly R410A refrigerant 3, 4, and 5 ton nominal capacities Multi-position applications

More information

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three

More information

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY PRODUCT SPECIFICATIONS APPLICATION 2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (11/2018) INSTALLATION One piece design Smaller profile for closet

More information

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY PRODUCT SPECIFICATIONS APPLICATION 1 1/2-5 ton systems Sequenced for demand management External access to heater circuit breakers FORM NO. -100 (12/2018) INSTALLATION 1 piece design Smaller profile for

More information

ELITE Series R-410A - Two-Stage Compressor

ELITE Series R-410A - Two-Stage Compressor AIR CONDITIONERS XC16 ELITE Series R-410A - Two-Stage Compressor Bulletin 210743 June 2015 P R O D U C T S P E C I F I C AT I O N S Supersedes April 2015 SEER up to 17.00 2 to 5 Tons Cooling Capacity -

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

BCE3V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

BCE3V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER FORM NO. -100 (03/2017) APPLICATION 1.5-5 ton systems Upflow and horizontal Sequenced for demand management External access to heater circuit breakers INSTALLATION

More information

ELITE COMMERCIAL SPLIT SYSTEMS UPFLOW/HORIZONTAL - R-410A - 60 HZ

ELITE COMMERCIAL SPLIT SYSTEMS UPFLOW/HORIZONTAL - R-410A - 60 HZ PRODUCT SPECIFICATIONS AIR HANDLERS ELA ELITE COMMERCIAL SPLIT SYSTEMS UPFLOW/HORIZONTAL - R-40A - 60 HZ Bulletin No. 20806 February 208 80-240 Models 072-090-20-50 Models Nominal Capacity - 6 to 20 Tons

More information

ELITE Series R-410A - Two-Stage Compressor

ELITE Series R-410A - Two-Stage Compressor AIR CONDITIONERS XC16 ELITE Series R-410A - Two-Stage Compressor Bulletin 210743 November 2017 P R O D U C T S P E C I F I C AT I O N S Supersedes August 2017 SEER up to 17.00 2 to 5 Tons Cooling Capacity

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS AIR CONDITIONERS 13ACX MERIT Series R-410A Bulletin 210739 November 2017 Supersedes August 2017 SEER up to 15.50 1.5 to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh MODEL NUMBER

More information

13 HP x

13 HP x E N G I N E E R I N G D ATA H E A T P U M P O U T D O O R U N I T S 13HPX MERIT Series R-410A Bulletin 210460 December 2009 Supersedes November 2009 SEER up to 14.5 1.5 to 5 Tons Cooling Capacity - 18,000

More information

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353

More information

HS22 Bulletin # November 1992 Supersedes September 1990

HS22 Bulletin # November 1992 Supersedes September 1990 ENGINEERING DATA CANADIAN EDITION FEATURES Application The HS22 series condensing units feature extra high efficiency with minimum operating sound levels. Units have seasonal energy efficiency ratings

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.     DESCRIPTION TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

HS 29. ELITE SERIES SEER up to to 5 Tons Cooling Capacity 12,000 to 62,500 Btuh Bulletin No October 2004 Supersedes September 2003

HS 29. ELITE SERIES SEER up to to 5 Tons Cooling Capacity 12,000 to 62,500 Btuh Bulletin No October 2004 Supersedes September 2003 ENGINEERING DATA AIR CONDITIONERS HS29 ELITE SERIES SEER up to 12.95 1 to 5 Tons 12,000 to 62,500 Btuh Bulletin No. 210304 October 2004 Supersedes September 2003 Direct Drive Fan Lanced Aluminum Fins Heavy

More information

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS AIR CONDITIONERS ELS T-SERIES COMMERCIAL SPLIT SYSTEMS R-40A - 60 HZ Bulletin No. ELS-072-240 (2/208) P R O D U C T S P E C I F I C AT I O N S 072-090 Models 80-240 Models EER up to 2.0 6 to 20 Tons Cooling

More information

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS.   DESCRIPTION FEATURE TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHE18 THRU 60* DESCRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features FORM NO. H11-528 Supersedes Form No. H11-526 Rev. 1 AIR HANDLERS AIR HANDLERS RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant Features earth friendly refrigerant Includes an energy efficient

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable

More information

FORM NO. HSC-543 AIR HANDLERS

FORM NO. HSC-543 AIR HANDLERS FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure

More information

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C P A C K A G E D E L E C T R I C / E L E C T R I C 2SA13 60HZ E N G I N E E R I N G D A T A Bulletin No. 210454 August 06 Supersedes July 06 MODEL NUMBER IDENTIFICATION SEER 13.00 2 to 2.5 Tons Capacity

More information

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY PRODUCT SPECIFICATIONS STANDARD AIR HANDLER FORM NO. -100 (05/2014) APPLICATION 1 1/2-5 ton systems Upflow and horizontal (counterflow capable with kits) Sequenced for demand management External access

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal

More information

MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS

MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS ENGINEERING DATA Direct Drive Fan CONDENSING UNITS 13ACC MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS 1.5 to 5 Ton SEER up to 14.80 Net Capacity 18,300 to 61,000 Heavy Duty Louvered Steel Fan Guard Bulletin

More information

ELECTRIC HEAT AIR HANDLERS

ELECTRIC HEAT AIR HANDLERS ELECTRIC HEAT AIR HANDLERS 208/230V 1 1 /2 to 5 TONS High efficiency series for R-22 Certain models feature GE s new X-13 motor for enhanced SEER performance with most outdoor condensing units Multi-position

More information

VERIFIED ENERGY PERFORMANCE

VERIFIED ENERGY PERFORMANCE ENGINEERING DATA CONDENSING UNITS HS29 ELITE 11Z SERIES SINGLE PHASE SEER - 10.0 to 12.05-12,000 to 61,000 Btuh (3.5 to 17.6 ) Bulletin No. 210216 July 1999 Supersedes December 1997 Typical Application

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2005 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CB29M & CB30M Elite Series Units MULTI POSITION BLOWER COILS 504,79M 09/05 Supersedes 04/05 Litho U.S.A. RETAIN THESE INSTRUCTIONS

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-517 REV. 1 Supersedes Form No. H11-509 Rev. 7 AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are always just

More information

CBH17-95V Horizontal Unit CB V

CBH17-95V Horizontal Unit CB V E N G I N E E R I N G D T I R H N D L E R S CB17/CBH17 UP FLOW/HORIZONTL 60 HZ Bulletin No. 210070 July 2008 Supersedes May 2002 CBH17-95V Horizontal Unit CB17-95V Up-Flow Unit Nominal Capacity 7.5 to

More information

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) TECHNICAL SPECIFICATIONS HMG*T Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG*T series of air handlers, when combined with our heat pump or air conditioner, offer

More information

Ruud High Efficiency Air Handler

Ruud High Efficiency Air Handler Air Handlers Ruud High Efficiency Air Handler RHLL- Series X-1 (ECM) Efficiencies up to 16 SEER RHLL feature an X-1 (ECM) motor which provides enhanced SEER performance with most Ruud outdoor units. Versatile

More information

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) TECHNICAL SPECIFICATIONS HMG Series Air Handler 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The HMG Series of air handlers, when combined with our heat pump or air conditioner,

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

T-Class Split System Units R-410A - 50 HZ

T-Class Split System Units R-410A - 50 HZ E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S TS T-Class Split System Units R-40A - 50 HZ Bulletin No. 49035 February 200 Supersedes October 2009 MODEL NUMBER IDENTIFICATION Nominal Capacity

More information

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS 6EMMX Series Air Handler with TXV 14-15 SEER Residential System 18,000-60,000 tuh (Heat Pump & Air Conditioner) R-410A Refrigerant The 6EMMX Series of air handlers, when combined

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler /RHT- Series Constant Torque (ECM) Efficiencies up to 16 SEER /RHT feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most

More information

HP19 Bulletin No August 1994 Supersedes November 1993

HP19 Bulletin No August 1994 Supersedes November 1993 ENGINEERING DATA HP19 SERIES HEAT PUMP OUTDOOR UNITS 10.05 to 12.15 SEER *18,000 to 61,000 (5.3 to 17.9 ) *18,800 to 59,000 (5.5 to 17.3 ) *ARI Standard 210/240 certified Ratings HEAT PUMP OUTDOOR UNITS

More information

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHLP- Standard Efficiency X-13 (ECM) Motor RHLP features an X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 1 1 /2 ton [.3 kw] through

More information

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT FORM NO. H11-521 AIR HANDLERS earth friendly refrigerant RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal left and horizontal right. Available

More information

13 GCS X A X Nominal SEER Minor Revision Number

13 GCS X A X Nominal SEER Minor Revision Number PA C KA G E D G A S / E L E C T R I C 13GCSX ELITE SERIES Residential - R-410A P R O D U C T S P E C I F I C AT I O N S Bulletin No. 210422 April 2013 Supersedes June 2012 SEER - 13.00 AFUE - 80% 2 to

More information

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION FORM NO. H22-522 AIR HANDLERS earth friendly refrigerant PRELIMINARY NOT FOR DISTRIBUTION UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT Features Versatile 3-way convertible design for upflow, horizontal

More information

B6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

B6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner) TECHNICAL SPECIFICATIONS 6VMMX Series Air Handler with TXV 18,000-60,000 tuh (Heat Pump & Air Conditioner) The 6VMMX Series of air handlers, when combined with our heat pump or air conditioner, offers

More information

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M AIR CONDITIONERS ELS ELITE COMMERCIAL SPLIT SYSTEMS R-40A - 50 HZ Bulletin No. 49073 March 208 P R O D U C T S P E C I F I C AT I O N S Supersedes February 208 072-090 Models 80-240 Models 2 to 70 kw ing

More information

B6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

B6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) TECHNICAL SPECIFICATIONS B6BMMX Series Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The B6BMMX series of air handlers, when combined with our heat pump or air conditioner,

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS 14HPX MERIT Series R-410A Bulletin No. 210564 October 2017 Supersedes August 2017 SEER up to 16.00 1.5 to 5 Tons Capacity - 18,000 to 61,000 Btuh Heating

More information

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60 TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous

More information

AIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.

AIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant. FORM NO. H22-523 REV. 4 Supersedes Form No. H22-523 Rev. 3 AIR HANDLERS AIR HANDLERS UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant Features earth friendly

More information

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

HEAT PUMP AIR HANDLERS AND FAN COIL UNIT FORM NO. H66-515 Supersedes Form No. H66-5 Rev. 1 HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features 1 1 /2 ton [5 kw] through 5 ton [18 kw] models are always just 35 inches [889 mm] tall and 22 inches

More information

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...

More information

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency

More information

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P5RF Series Rev A Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

P7RE Series Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 BTUH The P7 Series single packaged air conditioners are high efficiency self contained

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

P7RE Series Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner 14 SEER 1½ thru 5 Ton Units Cooling: 17,800 to 56,000 BTUH The P7 Series single packaged air conditioners are high efficiency self contained

More information

Modular Variable Speed Air Handlers

Modular Variable Speed Air Handlers Modular Variable Speed Air Handlers Convertible Variable Speed Communicating Air Handlers - 1 1/2-5 Ton 4TEE3C01A1000A 4TEE3C02A1000A 4TEE3C03A1000A 4TEE3C04A1000A 4TEE3C05A1000A 4TEE3C06A1000A 4TEE3C07A1000A

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed

More information

P5RF Series Single Packaged Air Conditioner Single Phase

P5RF Series Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) TECHNICAL GUIDE TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE S: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS) LISTED Due to continuous product improvement, specifications are subject

More information

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 59,500 Btuh Heating Capacity - 16,900 to 56,000 Btuh

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 59,500 Btuh Heating Capacity - 16,900 to 56,000 Btuh PRODUCT SPECIFICATIONS heat pump outdoor units 13HPX MERIT Series R-410A Bulletin No. 210566 June 2015 Supersedes January 2015 SEER up to 15.00 1.5 to 5 Tons Capacity - 17,800 to 59,500 Btuh Heating Capacity

More information

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES Base Series Fan Coil Sizes 018 thru 036 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split system heat pumps and air

More information

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES LEGACY LINE FAN COIL SIZES 018 THRU 037 Product Data FEATURES The Series Fan Coil unit is primarily designed for apartment applications as upflow indoor air handlers for split-system heat pumps and air

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

HP25 HEAT PUMP OUTDOOR UNITS ELITE 12 HEAT PUMP OUTDOOR UNITS

HP25 HEAT PUMP OUTDOOR UNITS ELITE 12 HEAT PUMP OUTDOOR UNITS ENGINEERING DATA HEAT PUMP OUTDOOR UNITS ELITE 12 HEAT PUMP OUTDOOR UNITS 11.35 to 13.50 SEER *19,000 to 58,500 Btuh (5.6 to 17.1 ) *17,600 to 57,000 Btuh (5.2 to 16.7 ) *ARI Standard 210/240 and DOE Certified

More information

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh TECHNICAL SPECIFICATIONS P3R(A,C) Series Single Packaged Air Conditioner, Single Phase P3RA-10 SEER 2 thru 5 Ton Units Cooling: 24,000 to 59,000 Btuh P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1. TECHNICAL SPECIFICATIONS JT4BE Series High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series of heat pumps offers exceptional performance. The unit, when combined with

More information

TECHNICAL GUIDE DESCRIPTION

TECHNICAL GUIDE DESCRIPTION TECHNICAL GUE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER S: BRCS018 THRU 060 (1.5 THRU 5 NOMINAL TONS, 1 PH) H*BA-(T,W)036 THRU 090 (3 THRU 7.5 NOMINAL TONS, 3 PH) S: 018-060 (1 PH & 3 PH) S: 076-090 (3 PH)

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

XC21. DAVE LENNOX SIGNATURE COLLECTION R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

XC21. DAVE LENNOX SIGNATURE COLLECTION R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S A I R C O N D I T I O N E R S XC21 DAVE LENNOX SIGNATURE COLLECTION R 410A Two Stage ressor SilentComfort Technology E N G I N E E R I N G D A T A Bulletin No. 210414 April 2005 Supersedes March 2005 SEER

More information

MB6(B,E,V)M Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Modular Indoor Blower 13+ SEER Residential System. Additional MB6EM Features:

MB6(B,E,V)M Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Modular Indoor Blower 13+ SEER Residential System. Additional MB6EM Features: TECHNICAL SPECIFICATIONS MB6(B,E,V)M Series Modular Indoor Blower 13+ SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner) The MB6 Series Modular Indoor Blower offers exceptional flexibility

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

S-CLASS SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ

S-CLASS SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ AIR CONDITIONERS SSB S-CLASS SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ Bulletin 210466 November 2017 P R O D U C T S P E C I F I C AT I O N S Supersedes August 2017 S up to 16.50 3 to 5 Tons Cooling

More information

BCS2S. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS ACCESSORIES.

BCS2S. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS ACCESSORIES. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION 2-5 ton sizes Upflow and horizontal (counterflow capable with kit) Sequenced for demand management External access to heater

More information

BCS2**V. Enhanced Air Handler APPLICATION INSTALLATION CABINET ACCESSORIES COMPONENTS

BCS2**V. Enhanced Air Handler APPLICATION INSTALLATION CABINET ACCESSORIES COMPONENTS Enhanced Air Handler BCS2**V APPLICATION 2-5 ton sizes Upflow and horizontal (counterflow capable with kit) Sequenced for demand management External access to heater circuit breakers INSTALLATION 1 Piece

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GQ3RD Series Single Packaged Heat Pump, Single Phase GQ3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The GQ3 Series single packaged

More information