Elta Select Product Guide 2016

Size: px
Start display at page:

Download "Elta Select Product Guide 2016"

Transcription

1 Elta Select Guide 2016 Tel: +44 (0) Fax: +44 (0) visit: eltaselect.com

2 Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this All rights over material in this product guide are specifically owned by and reserved to Elta Fans Ltd, unless otherwise stated. Please seek permission before duplicating material which will constitute a breach of copyright and/or design right.

3 The Elta Select range represents the very best in Fans, Ventilation and Accessories. The new Elta Select Guide reflects a product range designed around customers needs by providing the best available technology. Browse through our comprehensive guide, full of new features and products and select from a range of products that you can be assured comply with the latest industry standards and regulations. The range is supplied in conjunction with a customer service approach that epitomises the very essence of what the Elta Select brand represents...integrity in everything we do. The Elta Select Guide allows you to select your fans responsibly.

4 WHAT IS ELTA SELECT? What to expect from our Select Range The Elta Select Guide reflects the continuing development of our high quality range of industrial & commercial fans and ventilation products for the building services market, which was originally launched in September Within it, you will see: ü All of our stocked range products ü Every product group features: - Quick Facts - Overview - Specification - Typical Applications - Key Performance Data - Dimensional Drawings - Accessories - Notes Section More detailed information for every product, such as full performance data, Specific Fan Power and sound and/or silencer data, can be found on eltaselect.com It s not just about products, you will also find information about the following: ü Indoor Air Quality ü Legislation ü Destratification ü Smoke and Car Park Ventilation ü Residential s ü Heat Recovery Units Plus more information on: ü Our fan selection software The fact is, choosing the right fan manufacturer for your requirements is an important decision. Which is why we thought a few facts about Elta Fans and the Select Range might help with that decision... It s not just about being one of the widest standard ranges of H&V products on the market today. Nor is it our extensive distributor network - We have over 90 distributors in the UK and in 36 countries across 5 continents. Nor is it the people Elta Fans attracts some of the most talented and experienced professionals in the H&V industry, providing excellence in technical support and a level of customer service that is the envy of many. Nor is it the depth of stock of standard products we carry, or the flexibility to respond quickly to more specialist product requirements. It is knowing that our customers come back to us time and time again. The product guide is divided up into categories, so you can quickly find the type of product you are looking for. Our products include: ü Window/Wall fans ü Ducted/Inline fans ü Roof fans and cowls ü High Temperature fans ü Hazardous Area fans ü Destratification fans ü Portable Cooling fans ü A wide range of accessories and controls, including: - Inverter Controllers - Electrical Accessories - Voltage Controllers - Auto Changeover Controllers 4 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

5 WHAT IS ELTA SELECT? What to expect from our Select Range We hold over 4m of stock in central England All of our stocked products are available for next day delivery Specialist carriage outside of normal hours is available on request Our engineers have over 200 years of combined experience 90 carefully chosen distributors in the UK, find your nearest at eltaselect.com Available worldwide in 36 countries across 5 continents Search our dedicated website any time Our friendly sales team are here to offer advice & technical support Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 5

6 INDOOR AIR QUALITY The reason for ventilation The rapid growth of industry and population density over the last century has led to wider use of man-made materials and a lack of fresh air for building occupants. This in turn has caused an increase in the incidence of allergies, asthma and eczema, correlating closely to the changes in the world around us. In 2007 the European Council adopted ambitious energy and climate change objectives for 2020 to reduce greenhouse gas emissions by 20%, rising to 30% if the conditions are right, to increase the share of renewable energy to 20% and to make a 20% improvement in energy efficiency.* In order to save energy, buildings are becoming increasingly more airtight. This can lead to an adverse affect on the health of occupants, with the average person spending 90% of their time indoors, as they are exposed to the chemicals from modern building fabrics and furnishings with no ventilation to filter them. Particularly vulnerable are the young, the old and people with existing respiratory and health problems. "With the average person spending 90% of their time indoors, ventilation is critical in order to prevent adverse health consequences" Inadequate ventilation leads to poor air quality causing occupant discomfort, health problems and damage to the building fabric. *Source: Energy A strategy for competitive, sustainable and secure energy. Publications Office of the European Union, Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

7 INDOOR AIR QUALITY The reason for ventilation Common factors affecting IAQ Advantages of good IAQ CHEMICALS AND VOLATILE ORGANIC COMPOUNDS Chemicals and VOCs are found in furnishings, man-made materials, adhesives, cleaners, pesticides and household products. Harmful effects vary from mild irritation to serious health problems dependent on the length of exposure and the chemical concentration levels. Greater insulation, less ventilation and a huge increase in new chemicals and products within new buildings, collectively induces chemical exposure and threats to health never previously experienced in human history.** CARBON MONOXIDE Carbon monoxide results from smoking and the use of combustion appliances. Carbon monoxide poisoning causes headaches, nausea, vomiting and fatigue. Exposure to an atmosphere containing 1% carbon monoxide for five minutes will result in losing consciousness followed by death. PARTICULATES Small particles from smoke, tobacco smoke, fibres, dust and spores can cause problems varying from allergies to cancer. HUMIDITY FROM COOKING, WASHING AND PERSPIRING Condensed moisture damages the building fabric and when combined with warmth, provides ideal conditions for mould growth and for dust mites to flourish. Dust mites, which can be found in bedding and carpets, can cause asthma and allergic skin reactions. MOULD SPORES Mould spores are present in the form of dust and trigger asthma, allergies and hay fever when inhaled. CARBON DIOXIDE & ODOURS Carbon dioxide is a product of human respiration and combustion. Increased carbon dioxide levels lead to a lack of concentration, drowsiness and to occupants feeling uncomfortable. Increased CO² levels are considered to be a reliable indicator that the ventilation rate has dropped below acceptable levels and that the levels of occupancy related contaminants are increasing. Increased CO² levels are particularly relevant for students and office and factory workers as they can cause reduced concentration and productivity. TEMPERATURE Concentration levels decrease rapidly once temperatures exceed 24 C, which results in reduced productivity for workers and an increase in accident rates. VENTILATION Well designed, installed and maintained ventilation systems delivering sufficient levels of fresh air and extracting the stale contaminated air will ensure that adequate levels of indoor air quality can be maintained. It is essential to ensure that regular maintenance and cleaning of the HEVAC systems including the air filters is carried out. Apart from the obvious health benefits, a well ventilated building will result in: ü Happier and more motivated occupants In the workplace this will lead to: ü Higher productivity levels ü Lower levels of absenteeism ü A more stable workforce Solutions from Elta Fans Elta Fans produce a range of fans, air handling units, controls and ancillary equipment to facilitate the provision of clean, fresh and tempered air, providing a comprehensive range of industrial, commercial and domestic ventilation products directly from stock, as well as larger standard and specialist products ranging from ATEX requirements to car park ventilation and emergency smoke extract applications. To find out more, visit eltafans.com **Source: The Green Building Debate. LEED. CERTIFICATION. Where Energy Efficiency Collides with Human Health. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 7

8 PRODUCT INDEX Window/ Wall 15 Compact SCP Axial Up to 5.61 m³/s Raptor SPA Axial Up to 6.27 m³/s Window/Wall SAX Centrifugal Up to 0.53 m³/s Ducted/ Inline Compact SCD Axial Up to 4.24 m³/s Raptor SDA Axial Up to 4.60 m³/s Viper SCC Centrifugal Up to 1.73 m³/s Jetflow HIT Centrifugal Up to 0.51 m³/s ISEO IMF Mixed Flow Up to 0.26 m³/s Mulitflow SEM Mixed Flow Up to 0.92 m³/s QUBe SQU Centrifugal Up to 3.9 m³/s Multiflow SMB Mixed Flow Up to 2.87 m³/s 131 Twinflow STD Centrifugal Up to 1.89 m³/s 8 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

9 PRODUCT INDEX Revolution SLC Axial Up to m³/s Compact PowerPlus SCPP Axial Up to 4.6 m³/s PowerPlus SPP Axial Up to 3.96 m³/s Miniflow SAMF Axial Up to 0.55 m³/s 94 Multiflow SEL Mixed Flow Up to 3.89 m³/s Hideaway SH Centrifugal Up to 0.37 m³/s Singleflow SSD Centrifugal Up to 1.87 m³/s Quietflow SQS Centrifugal Up to 1.87 m³/s Quietflow SQT Centrifugal Up to 1.82 m³/s Quietflow SQS DCV Centrifugal Up to 1.87 m³/s Quietflow SQT DCV Centrifugal Up to 1.82 m³/s Tel: Fax: Visit: eltaselect.com 9

10 Index Roof Heritage SCH Roof Up to 1.87 m3/s Heritage SCHT Roof Up to 4.17 m³/s Singleflow SSDR Roof Up to 1.72 m³/s 173 Skyflow SSR Roof Up to 30 roof pitch 177 Skyflow SSFV Roof Up to 30 roof pitch High Temperature Biflow SB (CYL) Bifurcated Up to 4.50 m3/s Biflow SB (CON) Bifurcated Up to 3.80 m3/s QUBE SQU-HT(s) Centrifugal Up to 3.90 m3/s Destratification 215 Portable 223 ZOO Fan SDF Destratification Up to 0.66 m3/s Cooling Raptor Cooler SRC Circulating Up to 1.82 m3/s 10 Tel: Fax: Visit: eltaselect.com

11 Index Twinflow STDR Roof Up to 1.65 m³/s Singleflow SSDR DCV Roof Up to 1.72 m³/s Twinflow STDR DCV Roof Up to 1.65 m³/s 170 Miniflow SMF Roof Up to 30 roof pitch 196 Hazardous Slim QUBE SSQU-HT Centrifugal Up to 5.22 m3/s Area Revolution SLCX ATEX Up to 6.80 m3/s Raptor SFB ATEX Up to 2.57 m3/s Tel: Fax: Visit: eltaselect.com 11

12 THE ERP DIRECTIVE Legislation and Key Points Regulations have been introduced under the Energy Related s (ErP) Directive in order to assist the Kyoto Protocol obligation to safeguard the environment in which we live, by increasing the total share of renewable energy in the EU to 20% by 2020, whilst increasing energy efficiency by 20%. Fans Regulation 327/2011 The Directive has set out minimum efficiency levels for fans, which includes all the principal fan types between 125W and 500kW input power. Where fans do not comply with the efficiency guidelines they will not be permitted to be marketed throughout Europe after these dates. A fan is considered as an axial or centrifugal fan only equipped with a housing which is a casing around the impeller that guides the gas stream towards, through and from the impeller. Examples of 327/2011 compliant fans Maximum flowrate 250 m³/h RVU 250 m³/h < maximum flowrate < 1000 m³/h RVU (if the manufacturer declares the ventilation units intended use as being exclusively for a residential ventilation application) NRVU (if the manufacturer does not declare the ventilation units intended use as being exclusively for a residential ventilation application) Maximum flowrate 1000 m³/h NRVU Regulation 1254/2014 sets out the labelling requirements for Residential s (RVU) and data that must be freely available regarding the product. Motors Regulation 640/2009 (and EU 4/2014) requires that motors with a rated output of kw must meet EITHER the IE3 efficiency level (driven direct online) OR the IE2 level if fitted with a variable speed drive. Ventilation Units Regulation 1253/2014 and 1254/2014 Regulation 1253/2014 has set out minimum efficiency levels for Ventilation Units where the electric power input is greater than 30W. Ventilation units are by definition equipped with a casing which is additional to the housing (327/2011) and implies the casing is defined as all parts of the ventilation unit additional to the housing that interfere with the airflow. s that would normally be called box-fans or roof-fans are ventilation units. These products must also be multi speed, used with a variable speed drive or EC (Electronic commutated), which can be considered as a variable speed drive The regulation also categorises product as either Residential (RVU) or Non-Residential (NRVU), there are also further definitions that can be obtained by referring to the regulation. By defining the product as either RVU or NRVU sets out the efficiency requirements that have to be met. What it means to you It is only possible for a fan manufacturer to CE mark a product and sell that product into the EU if it meets the requirements of the ErP Directive and regulation that categorises that product. In essence by purchasing from a reputable manufacturer that CE marks their product you have no concerns. It does mean that product is changing, new technologies are more prevalent such as EC, the wider use of Variable Speed Drives as examples. Also old technologies and product that is not efficient are being removed, this leads to better system designs and product selections that need to be made. What is next? Year Affects Regulation Comment 2017 Motors 640/ Ventilation Units 1253/ Ventilation Units 1254/ kW to 375kW motors either IE3 or IE2 + VSD Tighter efficiency requirements Removal of lowest energy classes on RVU Labels 12 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

13 Window/Wall Tel: Fax: Visit: eltaselect.com 13

14 14 Tel: Fax: Visit: eltaselect.com

15 COMPACT SCP Plate Mounted Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 10 standard sizes from 250mm to 800mm. ü Air volume flow rates up to 5.61 m³/s. ü Static pressures up to 234 Pa. ü Highly efficient, lightweight induction motors. ü Available in AC. Fully speed controllable. CASING The all metal fan casing and guard provide a long lasting and robust construction. The units have been constructed from mild steel and suitably treated to ensure full corrosion protection. The guard shall be bright zinc plated. Fan plates and motors shall have a powder coated polyester epoxy paint finish in pastel beige (RAL 7032). IMPELLER Adjustable pitch aerofoil impellers are provided with blades made from high quality GRP. Impellers are factory set at an angle to provide maximum performance. The hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are to be dynamically balanced to ISO Grade G6.3. MOTORS Three phase multi-voltage motors are wound for either (Delta) 230V/3Ph/50Hz or (Star) 400V/3Ph/50Hz connection, suitable for speed control when used with the Eltadrive VSD range of frequency inverter controls. Fans are suitable for operating temperatures between -20 C and +70 C fixed speed and -20 C and +50 C when used with a speed controller. Electrical connection to the motor shall be provided by an IP55 terminal box fitted to a 550mm long flying lead. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SCP units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Factories Sports Halls Shops Industrial Units Warehousing Schools Kitchens ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-EL, 149-POT Transformer Controller : 149-TC Inverter : 149-ODE Louvre Shutter : 064 Impeller Side Guard : 078C Wall Cowl : SWC Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 15

16 COMPACT SCP Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SCP250/4-1AC 1445 SCP315/4-1AC 1370 SCP350/4-1AC 1360 SCP500/4-1AC 1300 SCP560/4-1AC 1315 SCP630/4-1AC 1295 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet <125W W/(L/s) Outlet 42 m³/s Inlet <125W W/(L/s) Outlet 49 m³/s Inlet <125W W/(L/s) Outlet 50 m³/s Inlet W/(L/s) Outlet 57 m³/s Inlet W/(L/s) Outlet 62 m³/s Inlet W/(L/s) Outlet 65 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 16 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

17 COMPACT SCP Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min SCP250/4-3AC 1460 SCP315/4-3AC 1445 SCP350/4-3AC 1440 SCP400/4-3AC 1400 SCP450/4-3AC 1390 SCP450/4B-3AC 1375 SCP500/4-3AC 1405 SCP500/6-3AC 930 SCP560/4-3AC 1410 SCP560/6-3AC 880 SCP630/4-3AC 1420 SCP630/6-3AC 915 SCP710/4/6-3AC SCP710/6/8-3AC SCP800/6/8-3AC Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Peak Amps Motor Electrical Data Input kw / Y 3m m³/s Inlet <125W Mains W/(L/s) Outlet 42 m³/s Inlet <125W Mains W/(L/s) Outlet 49 m³/s Inlet <125W Mains W/(L/s) Outlet 50 m³/s Inlet Mains W/(L/s) Outlet 55 m³/s Inlet Mains W/(L/s) Outlet 58 m³/s Inlet Mains W/(L/s) Outlet 58 m³/s Inlet Mains W/(L/s) Outlet 61 m³/s Inlet Mains W/(L/s) Outlet 52 m³/s Inlet Mains W/(L/s) Outlet 64 m³/s Inlet Mains W/(L/s) Outlet 56 m³/s Inlet Mains W/(L/s) Outlet 67 m³/s Inlet Mains W/(L/s) Outlet 57 m³/s Inlet 62 W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 58 m³/s Inlet 56 W/(L/s) Outlet 58 m³/s Inlet Y W/(L/s) Outlet 54 m³/s Inlet 60 W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 53 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 17

18 COMPACT SCP Dimensional Data D E CTS 4-HOLES 10 DIA 550mm LENGTH OF 20mm FLEXIBLE CONDUIT COMPLETE WITH TERMINAL BOX MOUNTING FACE A B C F H G A B C D E F G H Weight kg 1PH SCP250/4-1AC SCP250/4-3AC SCP315/4-1AC SCP315/4-3AC SCP350/4-1AC SCP350/4-3AC SCP400/4-3AC SCP450/4-3AC SCP450/4B-3AC SCP500/4-1AC SCP500/4-3AC SCP500/6-3AC SCP560/4-1AC SCP560/4-3AC SCP560/6-3AC SCP630/4-1AC SCP630/4-3AC SCP630/6-3AC SCP710/4/6-3AC SCP710/6/8-3AC SCP800/6/8-3AC Dimensions are in mm. 3PH 18 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

19 COMPACT SCP Accessories Electronic Controller Transformer Controller Louvre Shutter Impeller Side Guard Wall Cowl Wiring Diagram SCP250/4-1AC C C SWC25/ SCP315/4-1AC C C SWC25/ SCP350/4-1AC C C SWC35/ SCP500/4-1AC 149-EL61TK 149-TC C C SWC45/ SCP560/4-1AC 149-EL61TK 149-TC C C SWC56/ SCP630/4-1AC TC C C SWC56/ Transformer Controller Inverter Controller 1PH-3PH IP66 Inverter Controller 1PH-3PH IP20 Inverter Controller 3PH-3PH IP66 Inverter Controller 3PH-3PH IP20 SCP250/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCP315/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCP350/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCP400/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCP450/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCP450/4B-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCP500/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCP500/6-3AC 149-TC ODE KA1Y 149-ODE KA12 SCP560/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCP560/6-3AC 149-TC ODE KA1Y 149-ODE KA12 SCP630/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCP630/6-3AC 149-TC ODE KA1Y 149-ODE KA12 SCP710/4/6-3AC 149-TC ODE KA4Y 149-ODE KA42 SCP710/6/8-3AC 149-TC ODE KA1Y 149-ODE KA12 SCP800/6/8-3AC 149-TC ODE KA1Y 149-ODE KA12 Louvre Shutter Impeller Side Guard Wall Cowl Wiring Diagram SCP250/4-3AC C C SWC25/ SCP315/4-3AC C C SWC25/ SCP350/4-3AC C C SWC35/ SCP400/4-3AC C C SWC35/ SCP450/4-3AC C C SWC45/ SCP450/4B-3AC C C SWC45/ SCP500/4-3AC C C SWC45/ SCP500/6-3AC C C SWC45/ SCP560/4-3AC C C SWC56/ SCP560/6-3AC C C SWC56/ SCP630/4-3AC C C SWC56/ SCP630/6-3AC C C SWC56/ SCP710/4/6-3AC C C SCP710/6/8-3AC C C SCP800/6/8-3AC C C Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 19

20 COMPACT SCP Notes 20 Tel: Fax: Visit: eltaselect.com

21 RAPTOR SPA Plate Mounted Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 9 standard sizes from 250mm to 710mm. ü Air volume flow rates up to 6.27 m³/s. ü Static pressures up to 298 Pa. ü Suitable for operating temperatures up to +70 C. ü Available in AC & EC. CASING The all metal fan casing and guard provide a long lasting and robust construction. The units have been constructed from mild steel and suitably treated to ensure full corrosion protection. The guard is powder coated polyester epoxy paint finish in black (RAL 9005). Fan plates are powder coated polyester epoxy paint finish in pastel beige (RAL 7032). IMPELLER Impellers are high quality Ziehl-Abegg Sickle Blade or FE2owlet in pressure die cast aluminium or high performance composite material providing enhanced aerodynamic properties, low noise and reliability, dynamically balanced to ISO Grade G6.3 and finished in black (RAL 9005). Ziehl-Abegg Sickle Blade and FE2owlet impellers provide significant noise reduction. MOTORS Motors are highly efficient, lightweight external rotor motors, insulated to Class F, with integral thermal overload protection. Sizes weatherproofed to IP44 Sizes weatherproofed to IP54. All fans are suitable for use with a speed controller. Electrical connection to the motor shall be provided by an IP55 terminal box fitted to a flying lead allowing the fan to be positioned conveniently to incoming electrical inputs. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SPA units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Sports Hall Squash Courts Schools & Colleges Shops Retail Parks Commercial Kitchens Factories Industrial Units Warehousing ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-EL Transformer Controller : 149-TC Louvre Shutter : 064 Wall Cowl : SWC Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 21

22 RAPTOR SPA Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SPA250/2-1AC 2119 SPA250/4-1AC 1368 SPA315/4-1AC 1320 SPA350/4-1AC 1286 SPA400/4-1AC 1372 SPA450/4-1AC 1323 SPA450/6-1AC 926 SPA500/4-1AC 1320 SPA500/6-1AC 918 SPA560/4-1AC 1350 SPA560/6-1AC 930 SPA630/6-1AC 892 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps SC Amps Input W 3m m³/s Inlet 50 - <125W W/(L/s) Outlet 50 m³/s Inlet 37 - <125W W/(L/s) Outlet 37 m³/s Inlet 44 - <125W W/(L/s) Outlet 45 m³/s Inlet 40 - <125W W/(L/s) Outlet 42 m³/s Inlet W/(L/s) Outlet 48 m³/s Inlet W/(L/s) Outlet 48 m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet W/(L/s) Outlet 50 m³/s Inlet W/(L/s) Outlet 44 m³/s Inlet W/(L/s) Outlet 63 m³/s Inlet W/(L/s) Outlet 52 m³/s Inlet W/(L/s) Outlet 50 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Overall static efficiency, r/min and FMEG values are per ISO installation category A. Peak 230V / 1Ph / 50Hz. 22 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

23 RAPTOR SPA Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz SPA400/4/6-3AC SPA450/4/6-3AC SPA500/4/6-3AC SPA560/4/6-3AC SPA630/4/6-3AC SPA630/6/8-3AC SPA710/4/6-3AC SPA710/6/8-3AC Speed r/min Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Peak Amps Motor Electrical Data SC Amps Input kw / Y 3m m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 46 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 45 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 47 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 51 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 45 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 45 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Overall static efficiency, r/min and FMEG values are per ISO installation category A. Peak 400V / 3Ph / 50Hz. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 23

24 RAPTOR SPA Performance, SFP & Electrical Data SINGLE Phase - 220V to 277V / 50Hz or 60Hz SPA250/2-1EC SPA250/2B-1EC SPA315/4-1EC SPA350/4-1EC SPA350/6-1EC SPA400/4-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 47 <125W m³/s Inlet W/(L/s) Outlet 35 m³/s Inlet * W/(L/s) 0.05 Outlet *20 m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 43 m³/s Inlet * W/(L/s) 0.05 Outlet *20 m³/s Inlet W/(L/s) Outlet 58 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet * W/(L/s) 0.08 Outlet *20 m³/s Inlet W/(L/s) Outlet 57 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet * W/(L/s) 0.05 Outlet *20 m³/s Inlet W/(L/s) Outlet 42 m³/s Inlet W/(L/s) Outlet 39 <125W m³/s Inlet W/(L/s) 0.05 Outlet 27 m³/s Inlet * W/(L/s) 0.03 Outlet *20 m³/s Inlet W/(L/s) Outlet 58 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet * W/(L/s) 0.03 Outlet *20 A variable speed drive is integrated within the fan. Data in accordance with ERP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. 24 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

25 RAPTOR SPA Performance, SFP & Electrical Data SINGLE Phase - 220V to 277V / 50Hz or 60Hz SPA450/4-1EC SPA500/4-1EC SPA560/4-1EC SPA630/4-1EC SPA710/6-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 39 m³/s Inlet W/(L/s) 0.04 Outlet 20 m³/s Inlet W/(L/s) Outlet 56 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 40 m³/s Inlet W/(L/s) 0.11 Outlet 20 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet Outlet m³/s Inlet W/(L/s) Outlet 38 m³/s Inlet W/(L/s) 0.09 Outlet 20 m³/s Inlet W/(L/s) Outlet 51 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 40 m³/s Inlet W/(L/s) 0.23 Outlet 20 m³/s Inlet W/(L/s) Outlet 51 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 33 m³/s Inlet W/(L/s) 0.05 Outlet 20 A variable speed drive is integrated within the fan. Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 25

26 RAPTOR SPA Performance, SFP & Electrical Data THREE Phase - 380V to 480V / 50Hz or 60Hz SPA500/4-3EC SPA560/4-3EC SPA630/4-3EC SPA710/6-3EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 58 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 42 m³/s Inlet * W/(L/s) 0.02 Outlet *20 m³/s Inlet W/(L/s) Outlet 56 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 42 m³/s Inlet * W/(L/s) 0.04 Outlet *20 m³/s Inlet W/(L/s) Outlet 54 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 43 m³/s Inlet * W/(L/s) 0.03 Outlet *20 m³/s Inlet W/(L/s) Outlet 54 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 36 m³/s Inlet * W/(L/s) 0.03 Outlet *20 A variable speed drive is integrated within the fan. Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. 26 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

27 RAPTOR SPA Dimensional Data 'D' 'E'CTRS FLYING LEAD COMPLETE WITH TERMINAL BOX 4-HOLES Ø'K' Ø 'A' Ø 'B' Ø 'C' 'F' 'H' 'G' 'J' A B C D E F G H J K Weight kg SPA250/2-1AC SPA250/2-1EC SPA250/2B-1EC SPA250/4-1AC SPA315/4-1AC SPA315/4-1EC SPA350/4-1AC SPA350/4-1EC SPA350/6-1EC SPA400/4-1AC SPA400/4-1EC SPA400/46-3AC SPA450/4-1AC SPA450/4-1EC SPA450/46-3AC SPA450/6-1AC SPA500/4-1AC SPA500/4-1EC SPA500/4-3EC SPA500/46-3AC SPA500/6-1AC SPA560/4-1AC SPA560/4-1EC SPA560/4-3EC SPA560/46-3AC SPA560/6-1AC SPA630/4-1EC SPA630/4-3EC SPA630/46-3AC SPA630/6-1AC SPA630/68-3AC SPA710/46-3AC SPA710/6-1EC SPA710/6-3EC SPA710/68-3AC Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 27

28 RAPTOR SPA Accessories Electronic Controller Transformer Controller Louvre Shutter Wall Cowl Wiring Diagram SPA250/2-1AC 149-EL TC C SWC25/ SPA250/4-1AC 149-EL TC C SWC25/ SPA315/4-1AC 149-EL TC C SWC25/ SPA350/4-1AC 149-EL TC C SWC35/ SPA400/4-1AC 149-EL61TK 149-TC C SWC35/ SPA450/4-1AC 149-EL61TK 149-TC C SWC45/ B SPA450/6-1AC 149-EL31TK 149-TC C SWC45/ B SPA500/4-1AC 149-EL61TK 149-TC C SWC45/ B SPA500/6-1AC 149-EL31TK 149-TC C SWC56/ B SPA560/4-1AC 149-EL61TK 149-TC C SWC56/ B SPA560/6-1AC 149-EL61TK 149-TC C SWC56/ B SPA630/6-1AC 149-EL61TK 149-TC C SWC56/ B Transformer Controller Louvre Shutter Wall Cowl Wiring Diagram SPA400/46-3AC 149-TC C SWC35/ SPA450/46-3AC 149-TC C SWC45/ SPA500/46-3AC 149-TC C SWC45/ SPA560/46-3AC 149-TC C SWC56/ SPA630/46-3AC 149-TC C SWC56/ SPA630/68-3AC 149-TC C SWC56/ SPA710/46-3AC 149-TC C SPA710/68-3AC 149-TC C Electronic Controller Louvre Shutter Wall Cowl Wiring Diagram SPA250/2-1EC 149-POT C SWC25/ SPA250/2B-1EC 149-POT C SWC25/ SPA315/4-1EC 149-POT C SWC25/ SPA350/4-1EC 149-POT C SWC35/ SPA350/6-1EC 149-POT C SWC35/ SPA400/4-1EC 149-POT C SWC35/ SPA450/4-1EC 149-POT C SWC35/ SPA500/4-1EC 149-POT C SWC45/ MOEA03K1 SPA560/4-1EC 149-POT C SWC56/ MOEA03K1 SPA630/4-1EC 149-POT C SWC56/ MOEA03K1 SPA710/6-1EC 149-POT C MOEA03K1 Electronic Controller Louvre Shutter Wall Cowl Wiring Diagram SPA500/4-3EC 149-POT C SWC45/ MOEA03K3 SPA560/4-3EC 149-POT C SWC56/ MOEA03K3 SPA630/4-3EC 149-POT C SWC56/ MOEA03K3 SPA710/6-3EC 149-POT C MOEA03K3 28 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

29 RAPTOR SPA Notes Tel: Fax: Visit: eltaselect.com 29

30 WINDOW/WALL SAX Window/Wall Mounted Centrifugal Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 2 standard sizes from 230mm to 305mm. ü Air volume flow rates up to 0.53 m³/s. ü Static pressures up to 80 Pa. ü Suitable for operating temperatures up to +40 C. ü Available in AC. CASING Unit casings shall be manufactured from shockproof, heat resistant white plastic. The fans shall be suitable for installation into window, wall or ceiling mounted applications. All built in units shall have a telescopic wall liner for installations between 240mm and 315mm and 5m 4 core cable to assist installation. The unit shall comply with Documents F1 of the Building Regulations and is BEAB approved. All units have IPX4 protection and are splash proof as required under current electrical regulations. IMPELLER Axial impellers shall be provided with fixed blade angles to meet the required duty. The impeller construction shall comprise of white plastic. MOTORS Motors have sealed for life, self lubricating bearings which do not require ventilation. They are sealed in a housing, ensuring quiet operation of the fan. Motors shall be Class B insulated to EN Motors are connected in accordance with EN , double insulated with in-built thermal overload protection. The fan shall be suitable for operating temperatures up to +40 C. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SAX units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Pubs Restaurants Offices Kitchens Factories School and Shops 30 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

31 WINDOW/WALL SAX Performance, SFP & Electrical Data SINGLE Phase to 240V / 50Hz Speed r/min Airflow m³/s Pressure Pa Motor Electrical Data Peak Amps Input W 3m SAX23/9A SAX23/9AR SAX23/9ARB SAX30/12A SAX30/12AR SAX30/12ARB Peak 230V / 1Ph / 50Hz. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 31

32 WINDOW/WALL SAX Dimensional Data WINDOW MOUNT A C B WALL MOUNT D E F Fan Size A B C D E F Weight kg SAX23/9A SAX23/9AR SAX23/9ARB SAX30/12A SAX30/12AR SAX30/12ARB Dimensions are in mm. 32 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

33 WINDOW/WALL SAX Notes Tel: Fax: Visit: eltaselect.com 33

34 WINDOW/WALL SAX Notes 34 Tel: Fax: Visit: eltaselect.com

35 Ducted/Inline

36 36 Tel: Fax: Visit: eltaselect.com

37 COMPACT SCD Case Mounted Axial Flow Fan Ducted/Inline For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 6 standard sizes from 315mm to 630mm. ü Air volume flow rates up to 4.24 m³/s. ü Static pressures up to 191 Pa. ü Suitable for operating temperatures up to +70 C. ü Available in AC. CASING The all metal fan casing provides a long lasting and robust construction.the units have been constructed from mild steel and suitably treated to ensure full corrosion protection, with both motors and axial impellers mounted within the length of the unit casing. All casing parts shall have a powder coated polyester epoxy paint finish in pastel beige (RAL 7032). IMPELLER Adjustable pitch aerofoil impellers are provided with blades made from high quality GRP. Impellers are factory set at an angle to provide maximum performance. The hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are to be dynamically balanced to ISO Grade G6.3. MOTORS Three phase multi-voltage motors are wound for either (Delta) 230V/3Ph/50Hz or (Star) 400V/3Ph/50Hz connection, suitable for speed control when used with the Eltadrive VSD range of frequency inverter controls. Fans are suitable for operating temperatures between -20 C and +70 C fixed speed and -20 C and +50 C when used with a speed controller. Electrical connection to the motor is provided by an IP55 terminal box which is fitted onto the outer side of the fan casing. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SCD units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-EL Transformer Controller : 149-TC Inverter : 149-ODE Impeller Side Guard : 078C Wall Cowl : SWC Ancillary Pack : APK Mounting Feet : 060A Matching Flanges : 061A Flexible Connections : 063 MAN AV Mounts (Set of 4) : TYPICAL APPLICATIONS Silencer : 068 DE*P(C) Factories Sports Halls Shops Industrial Units Warehousing Schools Kitchens Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 37

38 COMPACT SCD Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min SCD315/4-3AC 1435 SCD350/4-3AC 1435 SCD450/4-3AC 1405 SCD500/4-3AC 1435 SCD560/4-3AC 1445 SCD630/4-3AC 1435 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet <125W W/(L/s) Outlet 49 m³/s Inlet <125W W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet 59 m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet 61 m³/s Inlet W/(L/s) Outlet 67 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 38 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

39 COMPACT SCD Dimensional Data B A TERMINAL BOX FITTED AS STANDARD COMPLETE WITH CONNECTION BLOCK. CABLE ENTRY IS 21 D E HOLES F EQUI-SPACED ON G PCD C A B C D E F G Weight kg SCD SCD SCD SCD SCD SCD Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 39

40 COMPACT SCD Accessories Transformer Controller Inverter Controller 1PH-3PH IP66 Inverter Controller 1PH-3PH IP20 Inverter Controller 3PH-3PH IP66 Inverter Controller 3PH-3PH IP20 Impeller Side Guard SCD315/4-3AC 149-TC C-0315-C SCD350/4-3AC 149-TC C-0350-C SCD450/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0450-C SCD500/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0500-C SCD560/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0560-C SCD630/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0630-C Wall Cowl Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) SCD315/4-3AC SWC25/31 APK315SCD/ A-0315-C 061A-0315-C MAN SCD350/4-3AC SWC35/40 APK350SCD/ A-0350-C 061A-0350-C MAN SCD450/4-3AC SWC45/50 APK450SCD/ A-0450-C 061A-0450-C MAN SCD500/4-3AC SWC45/50 APK500SCD/ A-0500-C 061A-0500-C MAN SCD560/4-3AC SWC56/63 APK560SCD/ A-0560-C 061A-0560-C MAN SCD630/4-3AC SWC56/63 APK630SCD/ A-0630-C 061A-0630-C MAN Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded Wiring Diagram SCD315/4-3AC DEP DENP DEP DENP SCD350/4-3AC DEP DENP DEP DENP SCD450/4-3AC DEPC DENPC DEPC DENPC SCD500/4-3AC DEPC DENPC DEPC DENPC SCD560/4-3AC DEPC DENPC DEPC DENPC SCD630/4-3AC DEPC DENPC DEPC DENPC * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. 40 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

41 COMPACT SCD Notes Tel: Fax: Visit: eltaselect.com 41

42 RAPTOR SDA Case Mounted Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 7 standard sizes from 250mm to 630mm. ü Air volume flow rates up to 4.60 m³/s. ü Static pressures up to 290 Pa. ü Suitable for operating temperatures up to +70 C. ü Available in AC & EC. CASING The all metal fan casing and guard provide a long lasting and robust construction. The units have been constructed from mild steel and suitably treated to ensure full corrosion protection. The guard is powder coated polyester epoxy paint finish in black (RAL 9005). Fan casings are powder coated polyester epoxy paint finish in pastel beige (RAL 7032). IMPELLER Impellers are high quality Ziehl-Abegg Sickle Blade or FE2owlet in pressure die cast aluminium or high performance composite material providing enhanced aerodynamic properties, low noise and reliability, dynamically balanced to ISO Grade G6.3 and finished in black (RAL 9005). Ziehl-Abegg Sickle Blade and FE2owlet impellers provide significant noise reduction. MOTORS Motors are highly efficient, lightweight external rotor motors, insulated to Class F, with integral thermal overload protection. Sizes weatherproofed to IP44. Sizes weatherproofed to IP54. All fans are suitable for use with a speed controller. Electrical connection to the motor shall be provided by an IP55 terminal box. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SDA units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Sports Halls Squash Courts Schools & Colleges Shops Retail Parks Commercial Kitchens Factories Industrial Units Warehousing ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-EL, 149-POT Transformer Controller : 149-TC Ancillary Pack : APK Mounting Feet : 060A Matching Flanges : 061A Flexible Connections : 063 MAN AV Mounts (Set of 4) : Silencer : 068 DE*P(C) Wall Cowl : SWC 42 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

43 RAPTOR SDA Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SDA250/4-1AC 1374 SDA400/4-1AC 1359 SDA450/4-1AC 1302 SDA450/6-1AC 915 SDA500/4-1AC* 1359 SDA500/6-1AC 910 SDA560/4-1AC 1341 SDA560/6-1AC 924 SDA630/6-1AC 872 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet 39 - <125W W/(L/s) Outlet 40 m³/s Inlet W/(L/s) Outlet 49 m³/s Inlet W/(L/s) Outlet 49 m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet W/(L/s) Outlet 51 m³/s Inlet W/(L/s) Outlet 46 m³/s Inlet W/(L/s) Outlet 63 m³/s Inlet W/(L/s) Outlet 52 m³/s Inlet W/(L/s) Outlet 50 THREE Phase - 380V to 415V / 50Hz SDA400/4/6-3AC SDA450/4/6-3AC SDA500/4/6-3AC SDA560/4/6-3AC SDA630/4/6-3AC SDA630/6/8-3AC Speed r/min Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw / Y 3m m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 46 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 45 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 48 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 51 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 59 m³/s Inlet W/(L/s) Outlet m³/s Inlet Y W/(L/s) Outlet 44 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. *An Inverter must be installed with this fan. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 43

44 RAPTOR SDA Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SDA250/2-1EC SDA250/2B-1EC SDA350/4-1EC SDA350/6-1EC SDA400/4-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 54 m³/s Inlet W/(L/s) Outlet 48 <125W m³/s Inlet W/(L/s) Outlet 37 m³/s Inlet 20* W/(L/s) 0.04 Outlet 20* m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 44 m³/s Inlet 20* W/(L/s) 0.05 Outlet 20* m³/s Inlet W/(L/s) Outlet 58 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet 20* W/(L/s) 0.05 Outlet 20* m³/s Inlet W/(L/s) Outlet 43 m³/s Inlet W/(L/s) Outlet 40 <125W m³/s Inlet W/(L/s) 0.06 Outlet 29 m³/s Inlet 20* W/(L/s) 0.03 Outlet 20* m³/s Inlet W/(L/s) Outlet 58 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet 20* W/(L/s) 0.04 Outlet 20* A variable speed drive is integrated within the fan. Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 44 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

45 RAPTOR SDA Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SDA450/4-1EC SDA500/4-1EC SDA560/4-1EC SDA630/4-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 56 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) 0.05 Outlet 41 m³/s Inlet 20* W/(L/s) 0.04 Outlet 20* m³/s Inlet W/(L/s) Outlet 57 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet 20* W/(L/s) 0.08 Outlet 20* m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 39 m³/s Inlet W/(L/s) 0.08 Outlet 20 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet 20* W/(L/s) 0.12 Outlet 20* A variable speed drive is integrated within the fan. Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 45

46 RAPTOR SDA Performance, SFP & Electrical Data THREE Phase - 380V to 480V / 50Hz or 60Hz SDA500/4-3EC SDA560/4-3EC SDA630/4-3EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 58 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 43 m³/s Inlet 20* W/(L/s) 0.04 Outlet 20* m³/s Inlet W/(L/s) Outlet 57 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 42 m³/s Inlet 20* W/(L/s) 0.04 Outlet 20* m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet m³/s Inlet W/(L/s) Outlet 43 m³/s Inlet 20* W/(L/s) 0.03 Outlet 20* A variable speed drive is integrated within the fan. Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 46 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

47 RAPTOR SDA Dimensional Data ØB ØA A SECTION A-A TERMINAL BOX FITTED AS STANDARD COMPLETE WITH CONECTION BLOCK CABLE ENTRY IS Ø21 D *SDA630/4/6-3AC, 33mm A E HOLES ØF EQUI-SPACED ON G PCD C A B C D E F G Weight kg SDA250/ SDA350/ SDA400/ SDA400/4/ SDA450/ SDA450/ SDA450/4/ SDA500/ SDA500/ SDA500/4/ SDA560/ SDA560/ SDA560/4/ SDA630/ SDA630/4/ SDA630/6/ Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 47

48 RAPTOR SDA Accessories Electronic Controller Transformer Controller Wall Cowl Ancillary Pack* Mounting Feet (each) Matching Flanges (each) SDA250/4-1AC 149-EL TC12 SWC25/31 APK250SCD/ A-0250-C 061A-0250-C SDA400/4-1AC 149-EL31TK 149-TC12 SWC35/40 APK400SCD/ A-0400-C 061A-0400-C SDA450/4-1AC 149-EL31TK 149-TC12 SWC45/50 APK450SCD/ A-0450-C 061A-0450-C SDA450/6-1AC 149-EL31TK 149-TC1 SWC45/50 APK450SCD/ A-0450-C 061A-0450-C SDA500/4-1AC 149-FXET4AMQ - SWC45/50 APK500SCD/ A-0500-C 061A-0500-C SDA500/6-1AC 149-EL31TK 149-TC12 SWC45/50 APK500SCD/ A-0500-C 061A-0500-C SDA560/4-1AC TC110 SWC56/63 APK560SCD/ A-0560-C 061A-0560-C SDA560/6-1AC 149-EL31TK 149-TC14 SWC56/63 APK560SCD/ A-0560-C 061A-0560-C SDA630/6-1AC 149-EL61TK 149-TC14 SWC56/63 APK630SCD/ A-0630-C 061A-0630-C Flexible Connections (each) AV Mounts (set of 4) Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded Wiring Diagram SDA250/4-1AC MAN DEP DENP DEP DENP SDA400/4-1AC MAN DEPC DENPC DEPC DENPC B SDA450/4-1AC MAN DEPC DENPC DEPC DENPC B SDA450/6-1AC MAN DEPC DENPC DEPC DENPC B SDA500/4-1AC MAN DEPC DENPC DEPC DENPC SDA500/6-1AC MAN DEPC DENPC DEPC DENPC B SDA560/4-1AC MAN DEPC DENPC DEPC DENPC B SDA560/6-1AC MAN DEPC DENPC DEPC DENPC B SDA630/6-1AC MAN DEPC DENPC DEPC DENPC B Transformer Controller Wall Cowl Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) SDA400/4/6-3AC 149-TC33 SWC35/40 APK400SCD/ A-0400-C 061A-0400-C MAN SDA450/4/6-3AC 149-TC33 SWC45/50 APK450SCD/ A-0450-C 061A-0450-C MAN SDA500/4/6-3AC 149-TC33 SWC45/50 APK500SCD/ A-0500-C 061A-0500-C MAN SDA560/4/6-3AC 149-TC33 SWC56/63 APK560SCD/ A-0560-C 061A-0560-C MAN SDA630/4/6-3AC 149-TC310 SWC56/63 APK630SCD/ A-0630-C 061A-0630-C MAN SDA630/6/8-3AC 149-TC33 SWC56/63 APK630SCD/ A-0630-C 061A-0630-C MAN Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded Wiring Diagram SDA400/4/6-3AC DEPC DENPC DEPC DENPC SDA450/4/6-3AC DEPC DENPC DEPC DENPC SDA500/4/6-3AC DEPC DENPC DEPC DENPC SDA560/4/6-3AC DEPC DENPC DEPC DENPC SDA630/4/6-3AC DEPC DENPC DEPC DENPC SDA630/6/8-3AC DEPC DENPC DEPC DENPC * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. 48 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

49 RAPTOR SDA Accessories Electronic Controller Wall Cowl Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) SDA250/2-1EC 149-POT-10 SWC25/31 APK250SCD/ A-0250-C 061A-0250-C MAN SDA250/2B-1EC 149-POT-10 SWC25/31 APK250SCD/ A-0250-C 061A-0250-C MAN SDA350/4-1EC 149-POT-10 SWC35/40 APK350SCD/ A-0350-C 061A-0350-C MAN SDA350/6-1EC 149-POT-10 SWC35/40 APK350SCD/ A-0350-C 061A-0350-C MAN SDA400/4-1EC 149-POT-10 SWC35/40 APK400SCD/ A-0400-C 061A-0400-C MAN SDA450/4-1EC 149-POT-10 SWC45/50 APK450SCD/ A-0450-C 061A-0450-C MAN SDA500/4-1EC 149-POT-10 SWC45/50 APK500SCD/ A-0500-C 061A-0500-C MAN SDA560/4-1EC 149-POT-10 SWC56/63 APK560SCD/ A-0560-C 061A-0560-C MAN SDA630/4-1EC 149-POT-10 SWC56/63 APK630SCD/ A-0630-C 061A-0630-C MAN Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded Wiring Diagram SDA250/2-1EC DEP DENP DEP DENP SDA250/2B-1EC DEP DENP DEP DENP SDA350/4-1EC DEP DENP DEP DENP SDA350/6-1EC DEP DENP DEP DENP SDA400/4-1EC DEPC DENPC DEPC DENPC SDA450/4-1EC DEPC DENPC DEPC DENPC SDA500/4-1EC DEPC DENPC DEPC DENPC 152-MOEA03K1 SDA560/4-1EC DEPC DENPC DEPC DENPC 152-MOEA03K1 SDA630/4-1EC DEPC DENPC DEPC DENPC 152-MOEA03K1 Electronic Controller Wall Cowl Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) SDA500/4-3EC 149-POT-10 SWC45/50 APK500SCD/ A-0500-C 061A-0500-C MAN SDA560/4-3EC 149-POT-10 SWC56/63 APK560SCD/ A-0560-C 061A-0560-C MAN SDA630/4-3EC 149-POT-10 SWC56/63 APK630SCD/ A-0630-C 061A-0630-C MAN Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded Wiring Diagram SDA500/4-3EC DEPC DENPC DEPC DENPC 152-MOEA03K3 SDA560/4-3EC DEPC DENPC DEPC DENPC 152-MOEA03K3 SDA630/4-3EC DEPC DENPC DEPC DENPC 152-MOEA03K3 * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 49

50 RAPTOR SDA Notes 50 Tel: Fax: Visit: eltaselect.com

51 VIPER SCC Duct Mounted Centrifugal Fan UK Patent Number GB For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 8 standard sizes from 250mm to 630mm. ü Air volume flow rates up to 1.73 m³/s (AC) and 1.73 m³/s (EC). ü Static pressures up to 660 Pa (AC) and 973 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Available in AC & EC. CASING The all metal fan casing and guard provide a long lasting and robust construction. The units have been constructed from mild steel and suitably treated to ensure full corrosion protection. The guard is powder coated polyester epoxy paint finish in black (RAL 9005). Fan casings are powder coated polyester epoxy paint finish in pastel beige (RAL 7032). IMPELLER High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit. MOTORS The units may have either an EC or AC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability. All motors are suitable for use in ambient air conditions up to +60 C. Electrical connection to the motor shall be provided by an IP55 terminal box. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SCC units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Sports Hall Squash Courts Schools & Colleges Shops Retail Parks Commercial Kitchens Factories Industrial Units Warehousing ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-POT Transformer Controller : 149-TC Ancillary Pack : APK Mounting Feet : 060A Matching Flanges : 061A Flexible Connections : 063 MAN AV Mounts (Set of 4) : Silencer : 068 DE*P(C) Impeller Side Guard : 078C Wall Cowl : SWC Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 51

52 VIPER SCC Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SCC250-1AC 2520 SCC315-1AC 2585 SCC350-1AC 2755 SCC400-1AC 2740 SCC450-1AC 1283 SCC500-1AC 1392 SCC560-1AC 1350 SCC630-1AC 1415 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet W/(L/s) Outlet 48 m³/s Inlet W/(L/s) Outlet 50 m³/s Inlet W/(L/s) Outlet 49 m³/s Inlet W/(L/s) Outlet 44 m³/s Inlet W/(L/s) Outlet 43 m³/s Inlet W/(L/s) Outlet 50 m³/s Inlet W/(L/s) Outlet 58 Peak Amps SC Amps Input kw 3m Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 52 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

53 VIPER SCC Performance, SFP & Electrical Data SINGLE Phase - 220V to 277V / 50Hz or 60Hz SCC250-1EC SCC315-1EC SCC350-1EC SCC400-1EC SCC450-1EC SCC500-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data 3m Peak Input Amps kw m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 52 m³/s Inlet W/(L/s) Outlet 40 m³/s Inlet 20* W/(L/s) Outlet 20* m³/s Inlet W/(L/s) Outlet 52 m³/s Inlet W/(L/s) Outlet 48 m³/s Inlet W/(L/s) Outlet 37 m³/s Inlet 20* W/(L/s) Outlet 20* m³/s Inlet W/(L/s) Outlet 51 m³/s Inlet W/(L/s) Outlet 46 m³/s Inlet W/(L/s) Outlet 38 m³/s Inlet W/(L/s) Outlet 30 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 49 m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet W/(L/s) Outlet 24 m³/s Inlet W/(L/s) Outlet 54 m³/s Inlet W/(L/s) Outlet 47 m³/s Inlet W/(L/s) Outlet 35 m³/s Inlet W/(L/s) 0.08 Outlet 26 m³/s Inlet W/(L/s) Outlet 58 m³/s Inlet W/(L/s) Outlet 52 m³/s Inlet W/(L/s) Outlet 39 m³/s Inlet 20* W/(L/s) 0.07 Outlet 21 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 53

54 VIPER SCC Performance, SFP & Electrical Data SINGLE Phase - 220V to 277V / 50Hz or 60Hz SCC560-1EC SCC630-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data 3m Peak Input Amps kw m³/s Inlet W/(L/s) Outlet 54 m³/s Inlet W/(L/s) Outlet 48 m³/s Inlet W/(L/s) Outlet 37 m³/s Inlet W/(L/s) 0.13 Outlet 22 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 46 m³/s Inlet W/(L/s) Outlet 34 m³/s Inlet 20* W/(L/s) 0.04 Outlet 20* THREE Phase - 380V to 480V / 50Hz or 60Hz Control Voltage Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input Kw 3m SCC630-3EC 10V 8V 5V 2V m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 39 m³/s Inlet W/(L/s) 0.07 Outlet 24 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. 54 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

55 VIPER SCC Dimensional Data Ø B Ø A TERMINAL BOX FITTED AS STANDARD COMPLETE WITH CONNECTION BLOCK. CABLE ENTRY Ø21 D E HOLES OF Ø F EQUI-SPACED ON G PCD C A B C D E F G Weight kg SCC SCC SCC SCC SCC SCC SCC SCC Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 55

56 VIPER SCC Accessories Transformer Controller Impeller Side Guard Wall Cowl Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) SCC250-1AC 149-TC12 078C-0250-C SWC25/31 APK250SCD/ A-0250-C 061A-0250-C MAN150 SCC315-1AC 149-TC12 078C-0315-C SWC25/31 APK315SCD/ A-0315-C 061A-0315-C MAN150 SCC350-1AC 149-TC12 078C-0350-C SWC35/40 APK350SCD/ A-0350-C 061A-0350-C MAN150 SCC400-1AC 149-TC12 078C-0400-C SWC35/40 APK400SCD/ A-0400-C 061A-0400-C MAN150 SCC450-1AC 149-TC12 078C-0450-C SWC45/50 APK450SCD/ A-0450-C 061A-0450-C MAN150 SCC500-1AC 149-TC12 078C-0500-C SWC45/50 APK500SCD/ A-0500-C 061A-0500-C MAN150 SCC560-1AC 149-TC18 078C-0560-C SWC56/63 APK560SCD/ A-0560-C 061A-0560-C MAN200 SCC630-1AC 149-TC C-0630-C SWC56/63 APK630SCD/ A-0630-C 061A-0630-C MAN200 AV Mounts (set of 4) Silencer 1D Unpodded Silencer 2D Unpodded Wiring Diagram SCC250-1AC DENP DENP SCC315-1AC DENP DENP SCC350-1AC DENP DENP SCC400-1AC DENPC DENPC SCC450-1AC DENPC DENPC SCC500-1AC DENPC DENPC A SCC560-1AC DENPC DENPC A SCC630-1AC DENPC DENPC A Electronic Controller Impeller Side Guard Wall Cowl Ancillary Pack* Mounting Feet (each) Matchin Flanges (each) Flexible Connetions (each) SCC250-1EC 149-POT C-0250-C SWC25/31 APK250SCD/ A-0250-C 061A-0250-C MAN150 SCC315-1EC 149-POT C-0315-C SWC25/31 APK315SCD/ A-0315-C 061A-0315-C MAN150 SCC350-1EC 149-POT C-0350-C SWC35/40 APK350SCD/ A-0350-C 061A-0350-C MAN150 SCC400-1EC 149-POT C-0400-C SWC35/40 APK400SCD/ A-0400-C 061A-0400-C MAN150 SCC450-1EC 149-POT C-0450-C SWC45/50 APK450SCD/ A-0450-C 061A-0450-C MAN150 SCC500-1EC 149-POT C-0500-C SWC45/50 APK500SCD/ A-0500-C 061A-0500-C MAN150 SCC560-1EC 149-POT C-0560-C SWC56/63 APK560SCD/ A-0560-C 061A-0560-C MAN200 SCC630-1EC 149-POT C-0630-C SWC56/63 APK630SCD/ A-0630-C 061A-0630-C MAN200 SCC630-3EC 149-POT C-0630-C SWC56/63 APK630SCD/ A-0630-C 061A-0630-C MAN200 AV Mounts (set of 4) Silencer 1D Unpodded Silencer 2D Unpodded Wiring Diagram SCC250-1EC DENP DENP SCC315-1EC DENP DENP SCC350-1EC DENP DENP SCC400-1EC DENPC DENPC SCC450-1EC DENPC DENPC SCC500-1EC DENPC DENPC 152-MOEA03K1 SCC560-1EC DENPC DENPC 152-MOEA03K1 SCC630-1EC DENPC DENPC 152-MOEA03K1 SCC630-3EC DENPC DENPC 152-MOEA03K1 * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. 56 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

57 VIPER SCC Notes Tel: Fax: Visit: eltaselect.com 57

58 REVOLUTION SLC Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 11 standard sizes from 315mm to 1000mm. ü Air volume flow rates up to m³/s. ü Static pressures up to 994 Pa. ü Suitable for operating temperatures up to +54 C. ü Available in AC. CASING The all metal fan casing provides a long lasting and robust construction. The units have been constructed from a single sheet of steel, with both motor and axial impeller mounted within the length of the unit casing. All casing parts are heavy gauge mild steel sheet, roll formed and welded for added strength and durability, hot dip galvanised to BS EN ISO 1461:2009 after fabrication and drilled to BS ISO 6580:2005 The fans are suitable for external mounting as standard. IMPELLER Adjustable pitch aerofoil impellers are provided with blades made from high quality pressure die cast aluminium (LM6), natural finish. Impellers are factory set at an angle to provide maximum performance. The hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are to be dynamically balanced to ISO Grade G6.3. MOTORS Motors are to be foot mounted totally enclosed metric type to IP55, with sealed for life bearings, standard industrial paint finish and Class F insulation to EN , suitable for operating temperatures up to +54 C. Motors are to be wired via a weatherproofed cable to an IP55 protected terminal box mounted on the outside of the unit casing. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SLC units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). ACCESSORIES For full accessories & controls information please visit eltaselect.com Transformer Controller : 149-TC Inverter : 149-ODE Ancillary Pack : APK Mounting Feet : 060B Matching Flanges : 061B Flexible Connections : 063 MAN AV Mounts (Set of 4) : Impeller Side Guard : 078C Damper : 019 Bell Mouth Inlet : 241B TYPICAL APPLICATIONS Silencer : 068 DE*P(C) Kitchen Canopy Systems Agriculture Sports Halls Industrial Units and Warehousing Factories Schools Air Conditioning Units Cooling Towers & Stations Marine Airports Hotels 58 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

59 REVOLUTION SLC Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SLC400/4-1AC 1435 SLC450/2-1AC 2815 SLC450/4-1AC 1465 SLC500/4A-1AC 1460 SLC500/4B-1AC 1440 SLC560/4A-1AC 1415 SLC560/4B-1AC 1460 SLC630/4-1AC 1375 SLC630/4B-1AC 1455 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 52 m³/s Inlet W/(L/s) Outlet 70 m³/s Inlet W/(L/s) Outlet 57 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 56 m³/s Inlet W/(L/s) Outlet 59 m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet 61 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 59

60 REVOLUTION SLC Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min SLC315/4-3AC 1435 SLC355/4-3AC 1435 SLC450/2A-3AC 2895 SLC450/4-3AC 1455 SLC500/2A-3AC 2920 SLC500/2B-3AC 2920 SLC500/4A-3AC 1435 SLC500/4B-3AC 1450 SLC560/2-3AC 2950 SLC560/4A-3AC 1450 SLC560/4B-3AC 1470 SLC560/4C-3AC 1460 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet <125W W/(L/s) Outlet 48 m³/s Inlet <125W W/(L/s) Outlet 43 m³/s Inlet W/(L/s) Outlet 72 m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet 69 m³/s Inlet W/(L/s) Outlet 71 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet 77 m³/s Inlet W/(L/s) Outlet 58 m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet 60 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 60 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

61 REVOLUTION SLC Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min SLC630/4A-3AC 1475 SLC630/4B-3AC 1460 SLC710/4A-3AC 1440 SLC710/4B-3AC 1460 SLC710/6A-3AC 910 SLC710/6B-3AC 940 SLC800/4A-3AC 1465 SLC800/4B-3AC 1460 SLC800/6A-3AC 940 SLC800/6B-3AC 955 SLC900/4A-3AC 1465 SLC900/4B-3AC 1470 SLC900/6A-3AC 955 SLC900/6B-3AC 960 SLC900/8-3AC 700 SLC1000/4A-3AC 1455 SLC1000/4B-3AC 1470 SLC1000/4C-3AC 1465 SLC1000/6A-3AC 955 SLC1000/6B-3AC 960 SLC1000/8-3AC 700 Airflow SFP Airflow Static Pressure Pa Overall FMEG Efficiency N % Motor Electrical Data Peak Amps SC Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 64 m³/s Inlet W/(L/s) Outlet 67 m³/s Inlet W/(L/s) Outlet 71 m³/s Inlet W/(L/s) Outlet 73 m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet 63 m³/s Inlet W/(L/s) Outlet 69 m³/s Inlet W/(L/s) Outlet 69 m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet 63 m³/s Inlet W/(L/s) Outlet 74 m³/s Inlet W/(L/s) Outlet 75 m³/s Inlet W/(L/s) Outlet 65 m³/s Inlet W/(L/s) Outlet 65 m³/s Inlet W/(L/s) Outlet 59 m³/s Inlet W/(L/s) Outlet 81 m³/s Inlet W/(L/s) Outlet 80 m³/s Inlet W/(L/s) Outlet 81 m³/s Inlet W/(L/s) Outlet 76 m³/s Inlet W/(L/s) Outlet 72 m³/s Inlet W/(L/s) Outlet 63 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 61

62 REVOLUTION SLC Dimensional Data B A CASING TERMINAL BOX WITH ENTRY HOLE TO SUIT K CONDUIT FITTINGS D AIR-FLOW E HOLES F EQUI-SPACED ON G PCD C Fan Dia. A B C D E F G K Weight kg SLC315/4-3AC SLC355/4-3AC SLC400/4-1AC SLC450/2-1AC SLC450/2A-3AC SLC450/4-1AC SLC450/4-3AC SLC500/2A-3AC SLC500/2B-3AC SLC500/ SLC560/2-3AC SLC560/ SLC630/ SLC710/4A-3AC SLC710/4B-3AC SLC710/6A-3AC SLC710/6B-3AC SLC800/4A-3AC SLC800/4B-3AC SLC800/6A-3AC SLC800/6B-3AC SLC900/4A-3AC SLC900/4B-3AC SLC900/6A-3AC SLC900/6B-3AC SLC900/8-3AC SLC1000/4A-3AC SLC1000/4B-3AC SLC1000/4C-3AC SLC1000/6A-3AC SLC1000/6B-3AC SLC1000/8-3AC Dimensions are in mm. 1Ph 3Ph 62 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

63 REVOLUTION SLC Accessories Transformer Controller Impeller Side Guard Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) SLC400/4-1AC 149-TC18 078C-0400-C APK400Sl/ B B MAN SLC450/2-1AC - 078C-0450-C APK450Sl/ B B MAN SLC450/4-1AC - 078C-0450-C APK450Sl/ B B MAN SLC500/4A-1AC 149-TC18 078C-0500-C APK500Sl/ B B MAN SLC500/4B-1AC 149-TC18 078C-0500-C APK500Sl/ B B MAN SLC560/4A-1AC 149-TC18 078C-0560-C APK560Sl/ B B MAN SLC560/4B-1AC 149-TC18 078C-0560-C APK560Sl/ B B MAN SLC630/4-1AC 149-TC18 078C-0630-C APK630Sl/ B B MAN SLC630/4B-1AC 149-TC18 078C-0630-C APK630Sl/ B B MAN Damper Bell Mouth Inlet Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded Wiring Diagram SLC400/4-1AC STD 241B-0400-BELL DEP DENP DEP DENP SLC450/2-1AC STD 241B-0450-BELL DEP DENP DEP DENP SLC450/4-1AC STD 241B-0450-BELL DEP DENP DEP DENP SLC500/4A-1AC STD 241B-0500-BELL DEP DENP DEP DENP SLC500/4B-1AC STD 241B-0500-BELL DEP DENP DEP DENP SLC560/4A-1AC STD 241B-0560-BELL DEP DENP DEP DENP SLC560/4B-1AC STD 241B-0560-BELL DEP DENP DEP DENP SLC630/4-1AC STD 241B-0630-BELL DEP DENP DEP DENP SLC630/4B-1AC STD 241B-0630-BELL DEP DENP DEP DENP * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 63

64 REVOLUTION SLC Accessories Transformer Controller Inverter Controller 1PH-3PH IP66 Inverter Controller 1PH-3PH IP20 Inverter Controller 3PH-3PH IP66 Inverter Controller 3PH-3PH IP20 Impeller Side Guard Ancillary Pack* Mounting Feet (each) SLC315/4-3AC 149-TC C-0315-C APK315Sl/ B-0315 SLC355/4-3AC 149-TC C-0350-C APK350Sl/ B-0355 SLC450/2A-3AC ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA42 078C-0450-C APK450Sl/ B-0450 SLC450/4-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0450-C APK450Sl/ B-0450 SLC500/2A-3AC ODE KA4Y 149-ODE KA42 078C-0500-C APK500Sl/ B-0500 SLC500/2B-3AC ODE KA4Y 149-ODE KA42 078C-0500-C APK500Sl/ B-0500 SLC500/4A-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0500-C APK500Sl/ B-0500 SLC500/4B-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0500-C APK500Sl/ B-0500 SLC560/2-3AC ODE KA4Y 149-ODE KA42 078C-0560-C APK560Sl/ B-0560 SLC560/4A-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0560-C APK560Sl/ B-0560 SLC560/4B-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0560-C APK560Sl/ B-0560 SLC560/4C-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0560-C APK560Sl/ B-0560 SLC630/4A-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0630-C APK630Sl/ B-0630 SLC630/4B-3AC 149-TC ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA42 078C-0630-C APK630Sl/ B-0630 SLC710/4A-3AC ODE KA4Y 149-ODE KA42 078C-0710-C APK710Sl/ B-0710 SLC710/4B-3AC ODE KA4Y 149-ODE KA42 078C-0710-C APK710Sl/ B-0710 SLC710/6A-3AC 149-TC ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 078C-0710-C APK710Sl/ B-0710 SLC710/6B-3AC 149-TC ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA42 078C-0710-C APK710Sl/ B-0710 SLC800/4A-3AC ODE KA4Y 149-ODE KA42 078C-0800-C APK800Sl/ B-0800 SLC800/4B-3AC ODE KA4Y 149-ODE KA42 078C-0800-C APK800Sl/ B-0800 SLC800/6A-3AC 149-TC ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA42 078C-0800-C APK800Sl/ B-0800 SLC800/6B-3AC ODE KA4Y 149-ODE KA42 078C-0800-C APK800Sl/ B-0800 SLC900/4A-3AC ODE KA4Y 149-ODE KA42 078C-0900-C APK900Sl/ B-0900 SLC900/4B-3AC ODE KA42 078C-0900-C APK900Sl/ B-0900 SLC900/6A-3AC ODE KA4Y 149-ODE KA42 078C-0900-C APK900Sl/ B-0900 SLC900/6B-3AC ODE KA4Y 149-ODE KA42 078C-0900-C APK900Sl/ B-0900 SLC900/8-3AC ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA42 078C-0900-C APK900Sl/ B-0900 SLC1000/4A-3AC ODE KA4Y 149-ODE KA42 078C-1000-C APK1000Sl/ B-1000 SLC1000/4B-3AC ODE KA42 078C-1000-C APK1000Sl/ B-1000 SLC1000/4C-3AC ODV IN 078C-1000-C APK1000Sl/ B-1000 SLC1000/6A-3AC ODE KA4Y 149-ODE KA42 078C-1000-C APK1000Sl/ B-1000 SLC1000/6B-3AC ODE KA4Y 149-ODE KA42 078C-1000-C APK1000Sl/ B-1000 SLC1000/8-3AC ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA42 078C-1000-C APK1000Sl/ B-1000 * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. 64 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

65 REVOLUTION SLC Accessories Matching Flanges (each) AV Flexible Mounts Connections (each) (set of 4) Damper Bell Mouth Inlet Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded Wiring Diagram SLC315/4-3AC 061B MAN STD 241B DEP DENP DEP DENP SLC355/4-3AC 061B MAN STD 241B DEP DENP DEP DENP SLC450/2A-3AC 061B MAN STD 241B-0450-BELL DEP DENP DEP DENP SLC450/4-3AC 061B MAN STD 241B-0450-BELL DEP DENP DEP DENP SLC500/2A-3AC 061B MAN STD 241B-0500-BELL DEP DENP DEP DENP SLC500/2B-3AC 061B MAN STD 241B-0500-BELL DEP DENP DEP DENP SLC500/4A-3AC 061B MAN STD 241B-0500-BELL DEP DENP DEP DENP SLC500/4B-3AC 061B MAN STD 241B-0500-BELL DEP DENP DEP DENP SLC560/2-3AC 061B MAN STD 241B-0560-BELL DEP DENP DEP DENP SLC560/4A-3AC 061B MAN STD 241B-0560-BELL DEP DENP DEP DENP SLC560/4B-3AC 061B MAN STD 241B-0560-BELL DEP DENP DEP DENP SLC560/4C-3AC 061B MAN STD 241B-0560-BELL DEP DENP DEP DENP SLC630/4A-3AC 061B MAN STD 241B-0630-BELL DEP DENP DEP DENP SLC630/4B-3AC 061B MAN STD 241B-0630-BELL DEP DENP DEP DENP SLC710/4A-3AC 061B MAN STD 241B-0710-BELL DEP DENP DEP DENP SLC710/4B-3AC 061B MAN STD 241B-0710-BELL DEP DENP DEP DENP SLC710/6A-3AC 061B MAN STD 241B-0710-BELL DEP DENP DEP DENP SLC710/6B-3AC 061B MAN STD 241B-0710-BELL DEP DENP DEP DENP SLC800/4A-3AC 061B MAN STD 241B-0800-BELL DEP DENP DEP DENP SLC800/4B-3AC 061B MAN STD 241B-0800-BELL DEP DENP DEP DENP SLC800/6A-3AC 061B MAN STD 241B-0800-BELL DEP DENP DEP DENP SLC800/6B-3AC 061B MAN STD 241B-0800-BELL DEP DENP DEP DENP SLC900/4A-3AC 061B MAN STD 241B-0900-BELL DEP DENP DEP DENP SLC900/4B-3AC 061B MAN STD 241B-0900-BELL DEP DENP DEP DENP SLC900/6A-3AC 061B MAN STD 241B-0900-BELL DEP DENP DEP DENP SLC900/6B-3AC 061B MAN STD 241B-0900-BELL DEP DENP DEP DENP SLC900/8-3AC 061B MAN STD 241B-0900-BELL DEP DENP DEP DENP SLC1000/4A-3AC 061B MAN STD 241B-1000-BELL DEP DENP DEP DENP SLC1000/4B-3AC 061B MAN STD 241B-1000-BELL DEP DENP DEP DENP SLC1000/4C-3AC 061B MAN STD 241B-1000-BELL DEP DENP DEP DENP SLC1000/6A-3AC 061B MAN STD 241B-1000-BELL DEP DENP DEP DENP SLC1000/6B-3AC 061B MAN STD 241B-1000-BELL DEP DENP DEP DENP SLC1000/8-3AC 061B MAN STD 241B-1000-BELL DEP DENP DEP DENP Fan & inverter packages available. Please contact Elta Fans for more information. Tel: Fax: Visit: eltaselect.com 65

66 REVOLUTION SLC Notes 66 Tel: Fax: Visit: eltaselect.com

67 POWERPLUS SCPP Contra-Rotating Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 4 standard sizes from 450mm to 630mm. ü Air volume flow rates up to 4.6 m³/s. ü Static pressures up to 475 Pa. ü Ideal for internal or external use. ü Available in AC. CASING The all metal fan casing provides a long lasting and robust construction. The units have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing. All casing parts are heavy gauge mild steel sheet, roll formed and welded, then hot dip galvanised to BS EN ISO 1461:2009 after fabrication. IMPELLER Adjustable pitch aerofoil impellers are provided with blades made from high quality pressure die cast aluminium (LM6), natural finish. Impellers are factory set at an angle to provide maximum performance. The hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are to be dynamically balanced to ISO Grade G6.3. MOTORS Motors are highly efficient, lightweight induction motors with sealed for life, maintenance free ball bearings, which allows the fan to be installed at any angle. Each motor is matched to the aerodynamic performance of the impeller. Motors are Class F insulated to EN , weatherproofed to IP55 and (excluding size 630) suitable for speed control. Each motor has integral thermal overload protection. Fans are suitable for operating temperatures between -20 C and +70 C fixed speed and -20 C and +50 C when used with a speed controller. Electrical connection to the motor is provided by an IP55 terminal box which is fitted onto the outer side of the fan casing. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SCPP units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). ACCESSORIES For full accessories & controls information please visit eltaselect.com Transformer Controller : 149-TC Ancillary Pack : APK Mounting Feet : 060B Matching Flanges : 061B Flexible Connections : 063 MAN AV Mounts (Set of 4) : Damper : 019 Bell Mouth Inlet : 241B Silencer : 068 DE*P(C) Impeller Side Guard : 078C TYPICAL APPLICATIONS Commercial Kitchens Sports Halls Industrial Units Warehousing Factories Schools Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 67

68 COMPACT POWERPLUS SCPP Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SCPP450/4-1AC 1465 SCPP500/4-1AC 1465 SCPP560/4-1AC 1375 SCPP630/4-1AC 1340 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data m³/s Inlet W/(L/s) Outlet 68 m³/s Inlet W/(L/s) Outlet 64 m³/s Inlet W/(L/s) Outlet 65 m³/s Inlet W/(L/s) Outlet - Peak Amps Input kw 3m Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 68 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

69 COMPACT POWERPLUS SCPP Dimensional Data E HOLES F EQUI- SPACED ON G PCD (BOTH FLANGES) 15 CASING TERMINAL BOX WITH ENTRY HOLE TO SUIT K CONDUIT FITTINGS D AIR-FLOW A B AIR-FLOW 1ST STAGE C 2ND STAGE Fan Dia A B C D E F G K Weight kg SCPP450/4-1AC SCPP500/4-1AC SCPP560/4-1AC SCPP630/4-1AC Dimensions are in mm. Accessories Transformer Controller Impeller Side Guard Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) SCPP450/4-1AC 149-TC C-0450-C APK450Sl/ B B MAN SCPP500/4-1AC 149-TC C-0500-C APK500Sl/ B B MAN SCPP560/4-1AC 149-TC C-0560-C APK560Sl/ B B MAN SCPP630/4-1AC - 078C-0630-C APK630Sl/ B B MAN Damper Bell Mouth Inlet Silencer 1D Podded** Silencer 1D Unpodded** Silencer 2D Podded** Silencer 2D Unpodded** Wiring Diagram SCPP450/4-1AC STD 241B-0450-BELL DEP DENP DEP DENP SCPP500/4-1AC STD 241B-0500-BELL DEP DENP DEP DENP SCPP560/4-1AC STD 241B-0560-BELL DEP DENP DEP DENP SCPP630/4-1AC STD 241B-0630-BELL DEP DENP DEP DENP * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. ** Melinex lined silencers must be used to prevent grease impregnation into the acoustic media for kitchen extract applications as prescribed for kitchen ventilation systems. Contact Elta Fans for insertion losses for melinex lined silencers. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 69

70 COMPACT POWERPLUS SCPP Notes 70 Tel: Fax: Visit: eltaselect.com

71 POWERPLUS SPP Contra-Rotating Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 5 standard sizes from 450mm to 630mm. ü Air volume flow rates up to 3.96 m³/s. ü Static pressures up to 764 Pa. ü Suitable for operating temperatures up to +70 C. ü Available in AC. CASING The all metal fan casing provides a long lasting and robust construction. The units have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing. All casing parts are heavy gauge mild steel sheet, roll formed and welded for added strength and durability, hot dip galvanised to BS EN ISO 1461:2009 after fabrication and drilled to BS ISO 6580:2005. The fans are suitable for external mounting as standard. IMPELLER Adjustable pitch aerofoil impellers are provided with blades made from high quality die cast aluminium (LM6). Impellers are factory set at an angle to provide maximum performance and efficiency across the duty range. The hubs are manufactured from die cast aluminium alloy (LM24). All impellers are to be dynamically balanced to ISO Grade G6.3. MOTORS Motors are totally enclosed, airstream rated induction motors with sealed for life, maintenance free ball bearings, which allows the fan to be installed at any angle. Each motor is matched to the aerodynamic performance of the impeller. Motors are Class F insulated to EN , protected to IP55 and suitable for inverter speed control. Motors are suitable for 230V Delta and 400V Star connection. Fans are suitable for operating temperatures between -20 C and +70 C. Electrical connection to the motor is provided by an IP55 terminal box which is fitted onto the outer side of the fan casing. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SPP units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Commercial Kitchens Restaurants and Cafés Shops and Retail Parks Sports Halls Industrial Units Warehousing Factories Schools ACCESSORIES For full accessories & controls information please visit eltaselect.com Inverter : 149-ODE Ancillary Pack : APK Mounting Feet : 060B Matching Flanges : 061B Flexible Connections : 063 MAN AV Mounts (Set of 4) : Impeller Side Guard : 078C Damper : 019 Bell Mouth Inlet : 241B Silencer : 068 DE*P(C) Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 71

72 POWERPLUS SPP Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min SPP450/4-3AC 1415 SPP500/4A-3AC 1455 SPP500/4B-3AC 1445 SPP560/4-3AC 1440 SPP630/4-3AC 1460 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 70 m³/s Inlet W/(L/s) Outlet 67 m³/s Inlet W/(L/s) Outlet 68 m³/s Inlet W/(L/s) Outlet 70 m³/s Inlet W/(L/s) Outlet 74 Dimensional Data E HOLES Ø F EQUI- SPACED ON G PCD (BOTH FLANGES) 15 CASING TERMINAL BOX WITH ENTRY HOLE TO SUIT Ø K CONDUIT FITTINGS AIRFLOW D Ø A INSIDE Ø B OUTSIDE FLANGE AIRFLOW L M 4 HOLES Ø11 N CRS P CRS MOUNTING FEET A 2ND STAGE C OVERALL 1ST STAGE A B C D E F G K L M N P Weight kg SPP SPP SPP SPP Dimensions are in mm. *Weight does not include mounting feet. Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 72 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

73 POWERPLUS SPP Accessories Inverter Controller 3PH-3PH IP66 Inverter Controller 3PH-3PH IP20 Inverter Controller 1PH-3PH IP66 Inverter Controller 1PH-3PH IP20 Impeller Side Guard Ancillary Pack* Mounting Feet (each) SPP450/4-3AC 149-ODE KA1Y 149-ODE KA ODE KB1Y 149-ODE KB12 078C-0450-C APK450SI/ B-0450 SPP500/4A-3AC 149-ODE KA1Y 149-ODE KA ODE KB1Y 149-ODE KB12 078C-0500-C APK500SI/ B-0500 SPP500/4B-3AC 149-ODE KA1Y 149-ODE KA ODE KB1Y 149-ODE KB12 078C-0500-C APK500SI/ B-0500 SPP560/4-3AC 149-ODE KA1Y 149-ODE KA ODE KB1Y 149-ODE KB12 078C-0560-C APK560SI/ B-0560 SPP630/4-3AC 149-ODE KA4Y 149-ODE KA ODE KB4Y 149-ODE KB42 078C-0630-C APK630SI/ B-0630 Mounting Flanges (each) Flexible Connections (each) AV Mounts (set of 4) Damper Bell Mouth Inlet Silencer 1D Podded** Silencer 1D Unpodded** Silencer 2D Podded** SPP450/4-3AC 061B MAN STD 241B-0450-BELL DEP DENP DEP SPP500/4A-3AC 061B MAN STD 241B-0500-BELL DEP DENP DEP SPP500/4B-3AC 061B MAN STD 241B-0500-BELL DEP DENP DEP SPP560/4-3AC 061B MAN STD 241B-0560-BELL DEP DENP DEP SPP630/4-3AC 061B MAN STD 241B-0630-BELL DEP DENP DEP Silencer 2D Unpodded** Wiring Diagram SPP450/4-3AC DENP SPP500/4A-3AC DENP SPP500/4B-3AC DENP SPP560/4-3AC DENP SPP630/4-3AC DENP Fan & inverter packages available. Please contact Elta Fans for more information. * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. ** Melinex lined silencers must be used to prevent grease impregnation into the acoustic media for kitchen extract applications as prescribed for kitchen ventilation systems. Contact Elta Fans for insertion losses for melinex lined silencers. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 73

74 POWERPLUS SPP Notes 74 Tel: Fax: Visit: eltaselect.com

75 MINIFLOW SAMF Cased Axial Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 4 standard sizes from 150mm to 315mm. ü Air volume flow rates up to 0.55 m³/s. ü Static pressures up to 150 Pa. ü Suitable for operating temperatures up to +50 C. ü Available in AC. CASING The all metal fan casing provides a long lasting and robust construction. The units have been constructed from mild steel, with mounting brackets as an integral component. Both motors and axial impellers mounted within the length of the unit casing. All casing parts shall have a powder coated finish after manufacture, except the SAMF150/2-2 which has a die cast aluminium housing. IMPELLER The impeller is aerodynamically designed by combining the impeller with the rotor of the external rotor motor. Motor and impeller are balanced to ISO Grade G6.3. MOTORS External rotor motor, with sealed for life ball bearings, allowing the unit to be mounted at any angle. Motors shall be IP44 protected and Class B insulation. All units are suitable for a maximum of 80% R.H. and ambient operating temperatures up to +50 C. Motors are wound for 220V to 240V/1Ph/50Hz AC supply, with built in thermal overload protection, except the SAMF150/2-2 which is impedance protected. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SAMF units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Small commercial premises Kitchens (where there is not an outside wall to terminate a wall fan) ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-EL Mounting Brackets (each) : 060A SAMF Flexible Connections : 063 SAMF Clamps (each) : 018 CLAMP AV Mounts (Set of 4) : Damper : 018 DAMPER Silencer : 068 JF Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 75

76 MINIFLOW SAMF Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SAMF150/ SAMF200/ SAMF200/ SAMF250/ SAMF250/ SAMF315/ Airflow SFP Airflow Static Pressure Pa Overall Efficiency % FMEG N Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet <125W W/(L/s) Outlet - m³/s Inlet <125W W/(L/s) Outlet - m³/s Inlet <125W W/(L/s) Outlet - m³/s Inlet <125W W/(L/s) Outlet - m³/s Inlet <125W W/(L/s) Outlet - m³/s Inlet <125W W/(L/s) Outlet - Dimensional Data 2-MOUNTING BRACKETS WITH 8mm SLOTTED HOLE ON CENTRE LINE (EXCEPT SIZE 150) TERMINAL BOX B A D C A B C D Weight kg SAMF SAMF SAMF SAMF Dimensions are in mm. Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 76 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

77 MINIFLOW SAMF Accessories Electronic Controller Mounting Brackets (each) Flexible Connections (each) Clamps (each) AV Mounts (set of 4) Damper SAMF150/ EL SAMF CLAMP DAMPER SAMF200/ EL31 060A-SAMF200-MB SAMF CLAMP DAMPER SAMF200/ EL31 060A-SAMF200-MB SAMF CLAMP DAMPER SAMF250/ EL31 060A-SAMF250-MB SAMF CLAMP DAMPER SAMF250/ EL31 060A-SAMF250-MB SAMF CLAMP DAMPER SAMF315/ EL31 060A-SAMF315-MB SAMF CLAMP DAMPER Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram SAMF150/ JF JF JF JF SAMF200/ JF JF JF JF SAMF200/ JF JF JF JF SAMF250/ JF JF JF JF SAMF250/ JF JF JF JF SAMF315/ JF JF JF JF Tel: Fax: Visit: eltaselect.com 77

78 MINIFLOW SAMF Notes 78 Tel: Fax: Visit: eltaselect.com

79 JETFLOW HIT Centrifugal In-line Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 5 standard sizes from 150mm to 315mm. ü Air volume flow rates up to 0.51 m³/s. ü Static pressures up to 650 Pa. ü Suitable for operating temperatures up to +50 C. ü Available in AC. CASING HIT casings have a galvanised pressed sheet steel construction, providing a robust, long lasting and corrosion resistant casing. The inlet and outlet spigots should be a minimum of 25mm long to enable the installation and fixing to circular rigid, or flexible ductwork. All HIT units are to be supplied complete with integral mounting brackets manufactured from galvanised sheet steel for horizontal or vertical mounting arrangements. IMPELLER All impellers are single inlet backward curved centrifugal type. Impellers are balanced to ISO Grade G6.3. MOTORS All motors are to be highly efficient, three speed external rotor motors; matched to the aerodynamic performance of the impeller. Motors have sealed for life ball bearings to enable the fan to be mounted at any angle. Motors are protected to IP44 with Class F insulation; suitable for speed control and ambient operating temperatures up to +50 C with built in thermal overload protection. Non self-resetting thermal cut-outs are fitted in accordance with EN Motors are wound for 230V/1Ph/50Hz/60Hz supply. Electrical connections are made by an IP54 terminal box fitted to the outside of the fan casing. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All HIT units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Variety of industrial, light commercial & domestic applications, including: Toilets Café Entrance Halls Duct Ventilation Boost Bathrooms Equipment Cooling Air Curtain Supply Restaurants ACCESSORIES For full accessories & controls information please visit eltaselect.com 3 Speed Switch : 149-MTS Flexible Connections : 018 FLEX Clamps (each) : 018 CLAMP Damper : 018 DAMPER Silencer : 068 JF Panel Filter : 018 FILT-P Electric Heater Battery : 018 HEA Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 79

80 JETFLOW HIT Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz HIT150 HIT160 HIT200 Speed r/min HIGH 2590 MED 2320 LOW 2180 HIGH 2500 MED 2170 LOW 2030 HIGH 2520 MED 2315 LOW 1420 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps SC Amps Input kw 3m Inlet 47 m³/s Outlet 49 W/(L/s) Breakout 43 Inlet 44 m³/s Outlet 45 W/(L/s) Breakout 39 Inlet 38 m³/s Outlet 39 W/(L/s) Breakout 35 Inlet 47 m³/s Outlet 49 W/(L/s) Breakout 43 Inlet 44 m³/s Outlet 45 W/(L/s) Breakout 39 Inlet 38 m³/s Outlet 39 W/(L/s) Breakout 35 Inlet 51 m³/s Outlet 53 W/(L/s) Breakout 47 Inlet 47 m³/s Outlet 48 W/(L/s) Breakout 43 Inlet 42 m³/s Outlet 41 W/(L/s) Breakout 36 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 80 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

81 JETFLOW HIT Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz HIT250 HIT250B HIT315 HIT315B Speed r/min HIGH 2400 MED 2290 LOW 1380 HIGH 2390 MED 2300 LOW 2090 HIGH 2270 MED 2010 LOW 1840 HIGH 2230 MED 2250 LOW 2140 Airflow SFP Airflow Static Pressure Pa m³/s Overall Efficiency % Motor Electrical Data Peak Amps SC Amps Input kw m Inlet 52 Outlet 56 W/(L/s) Breakout 50 m³/s Inlet 49 Outlet 52 W/(L/s) Breakout 45 m³/s Inlet 44 Outlet 47 W/(L/s) Breakout 40 m³/s Inlet 52 Outlet 56 W/(L/s) Breakout 47 m³/s Inlet 47 Outlet 50 W/(L/s) Breakout 41 m³/s Inlet 41 Outlet 42 W/(L/s) Breakout 36 m³/s Inlet 56 Outlet 56 W/(L/s) Breakout 48 m³/s Inlet 51 Outlet 51 W/(L/s) Breakout 41 m³/s Inlet 46 Outlet 47 W/(L/s) Breakout 36 m³/s Inlet 56 Outlet 58 W/(L/s) Breakout 46 m³/s Inlet 54 Outlet 56 W/(L/s) Breakout 48 m³/s Inlet 52 Outlet 54 W/(L/s) Breakout 49 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 81

82 JETFLOW HIT Dimensional Data 2-HOLES IN EACH BRACKET SIZES , O4 SIZES , O5 B E G F A DIA D DIA C A B C D E F G Weight kg HIT HIT HIT HIT250 & HIT250B HIT315 & HIT 315B Dimensions are in mm. 82 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

83 JETFLOW HIT Accessories 3 Speed Switch Flexible Connections (each) Clamps (each) Damper Panel Filter Electric Heater Battery HIT MTS FLEX CLAMP DAMPER FILT-P HEAT-1 HIT MTS FLEX CLAMP DAMPER FILT-P HEAT-1 HIT MTS FLEX CLAMP DAMPER FILT-P HEAT-1 HIT MTS FLEX CLAMP DAMPER FILT-P HEAT-1 HIT250B 149-MTS FLEX CLAMP DAMPER FILT-P HEAT-1 HIT MTS FLEX CLAMP DAMPER FILT-P HEA1/3 HIT315B 149-MTS FLEX CLAMP DAMPER FILT-P HEA1/3 Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram HIT JF JF JF JF HIT JF JF JF JF HIT JF JF JF JF HIT JF JF JF JF HIT250B JF JF JF JF HIT JF JF JF JF HIT315B JF JF JF JF Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 83

84 JETFLOW HIT Notes 84 Tel: Fax: Visit: eltaselect.com

85 ISEO IMF In-Line Mixed Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit homevent.co.uk. QUICK FACTS ü Moulded mounting bracket for quick installation ü Double Insulated, no earth connections required ü Totally recyclable plastic components, environmentally friendly ü Reliability Sealed for life ball bearings ü Motors Two speed AC permanent capacitor induction type ü Impeller Mixed flow impeller for high performance & silent operation CASING The all plastic fan casing provides a long lasting shockproof and robust construction. The units are finished in white RAL 9010 and are UV resistant. IMPELLER Mixed flow impellers are provided with blades made from high quality plastic. MOTORS Two speed permanent capacitor totally enclosed induction type with integral thermal overload protection, mounted on sealed for life ball bearings. All fans are double insulated. QUALITY MANAGEMENT All units in the Elta range are designed and manufactured to procedures as defined in BS EN ISO 9001:2008. TYPICAL APPLICATIONS Variety of industrial, light commercial & domestic applications, including: Toilets Café Entrance Halls Duct Ventilation Boost Bathrooms Equipment Cooling Air Curtain Supply Restaurants For full accessories & controls information please contact Elta Fans Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 85

86 ISEO IMF Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz ISEO IMF 100 ISEO IMF 100T ISEO IMF 125 ISEO IMF 125T ISEO IMF 150 ISEO IMF 150T ISEO IMF 200 ISEO IMF 200T Speed r/min Airflow SFP Airflow Static Pressure Pa m³/s Overall Efficiency % FMEG Motor Electrical Data Peak Amps Input kw 12.4 <125W m Inlet 47 Outlet 45 W/(L/s) Break Out 41 m³/s <125W Inlet 43 Outlet 41 W/(L/s) Break Out 36 m³/s <125W Inlet 47 Outlet 45 W/(L/s) Break Out 41 m³/s <125W Inlet 43 Outlet 41 W/(L/s) Break Out 36 m³/s <125W Inlet 44 Outlet 43 W/(L/s) Break Out 41 m³/s <125W Inlet 41 Outlet 38 W/(L/s) Break Out 36 m³/s <125W Inlet 44 Outlet 43 W/(L/s) Break Out 41 m³/s <125W Inlet 41 Outlet 38 W/(L/s) Break Out 36 m³/s <125W Inlet 49 Outlet 48 W/(L/s) Break Out 45 m³/s <125W Inlet 43 Outlet 43 W/(L/s) Break Out 38 m³/s <125W Inlet 49 Outlet 48 W/(L/s) Break Out 45 m³/s <125W Inlet 43 Outlet 43 W/(L/s) Break Out 38 m³/s <125W Inlet 53 Outlet 57 W/(L/s) Break Out 50 m³/s <125W Inlet 51 Outlet 53 W/(L/s) Break Out 45 m³/s <125W Inlet 53 Outlet 57 W/(L/s) Break Out 50 m³/s <125W Inlet 51 Outlet 53 W/(L/s) Break Out 45 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 86 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

87 ISEO IMF Dimensional Data G H B øf øa D E C A B C D E F G H ISEO IMF ISEO IMF ISEO IMF ISEO IMF Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 87

88 ISEO IMF Notes 88 Tel: Fax: Visit: eltaselect.com

89 MULTIFLOW SEM Mixed Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 5 standard sizes from 150mm to 400mm. ü Air volume flow rates up to m³/s. ü Static pressures up to 660 Pa (AC). ü Suitable for operating temperatures up to +60 C. ü Extensive stock range available. ü Available in AC and EC. CASING Shockproof, heat resistant plastic, long lasting, robust, non-corrosive construction, IPX4. MOTORS Three speed AC induction motor with an in-built thermostatic switch. IMPELLER High efficiency diagonal mixed flow impeller with three dimensional guide vanes. INSTALLATION Removable fan section. IP44 terminal box. Suitable for installation at any angle. QUALITY MANAGEMENT Commitment to quality runs deep within Elta, as with all of our building services products the Multiflow SEM range is designed and manufactured with procedures as defined in BS EN ISO 9001:2008 and tested to ISO 5801:2007 (airside performance) and EN : (sound performance). OPERATING TEMPERATURE AC units from -25 C to +60 C (model dependent). ACCESSORIES For full accessories & controls information please visit eltaselect.com 3 Speed Controller : 149 MTS Fast Clamps : 018 CLAMP Panel Filter : 018 FILT-P Silencer : 068 JF Electric Heater Battery : 018 HEA Matching Flanges : 061B Damper : 018 DAMPER Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 89

90 MULTIFLOW SEM Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SEM150/2-1AC 2730 SEM200/2-1AC 2740 SEM250/2-1AC 2822 SEM315/2-1AC 2778 SEM400/4-1AC 1414 Airflow SFP Airflow Pressure Pa At Best Efficiency Point Overall Efficiency % FMEG N Input kw Peak Amps 3m m³/s Inlet <125W Outlet 45 W/(L/s) Breakout 35 m³/s Inlet <125W Outlet 53 W/(L/s) Breakout 37 m³/s Inlet Outlet 57 W/(L/s) Breakout 39 m³/s Inlet Outlet 63 W/(L/s) Breakout 45 m³/s Inlet Outlet 53 W/(L/s) Breakout 35 AVAILABLE IN EC The Multiflow SEM is available in EC models on request. Please contact us for more information. Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 90 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

91 MULTIFLOW SEM Dimensional Data Ø F G D E Ø A H C B A B C D E F G H Weight kg SEM SEM SEM SEM SEM Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 91

92 MULTIFLOW SEM Accessories 3 Speed Controller Clamps (each) Damper Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long SEM150/2-1AC MTS CLAMP DAMPER JF JF JF JF4 SEM200/2-1AC MTS CLAMP DAMPER JF JF JF JF4 SEM250/2-1AC MTS CLAMP DAMPER JF JF JF JF4 SEM315/2-1AC MTS CLAMP DAMPER JF JF JF JF4 SEM400/4-1AC MTS CLAMP DAMPER JF JF JF JF4 Panel Filter Electric Heater Battery Wiring Diagram SEM150/2-1AC FILT-P HEAT SEM200/2-1AC FILT-P HEAT SEM250/2-1AC FILT-P HEAT SEM315/2-1AC FILT-P HEAT SEM400/4-1AC FILT-P HEAT Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

93 MULTIFLOW SEM Notes Tel: Fax: Visit: eltaselect.com 93

94 MULTIFLOW SEL Mixed Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 8 standard sizes from 250mm to 630mm. ü Air volume flow rates up to 3.88 m³/s (AC). ü Static pressures up to 1270 Pa (AC). ü Suitable for operating temperatures up to +80 C. ü Extensive stock range available. ü Available in AC and EC. CASING Manufactured from all weather galvanised steel, heat resistant plastic or seawater resistant aluminium (sizes over 400mm), IPX4. MOTORS AC single phase units are suitable for transformer control. IMPELLER High efficiency diagonal mixed flow impeller with three dimensional guide vanes. INSTALLATION Integral mounting bracket. IP44 terminal box. Suitable for installation at any angle. OPERATING TEMPERATURE From -25 C to +80 C (model dependent). QUALITY MANAGEMENT Commitment to quality runs deep within Elta, as with all of our building services products the Multiflow SEL range is designed and manufactured with procedures as defined in BS EN ISO 9001:2008 and tested to ISO 5801:2007 (airside performance) and EN : (sound performance). ACCESSORIES For full accessories & controls information please visit eltaselect.com Transformer Controller : 149-TC Fast Clamps : 018 CLAMP Panel Filter : 018 FILT-P Silencer : 068 JF Electric Heater Battery : 018 HEA Matching Flanges : 061B Damper : 018 DAMPER 94 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

95 MULTIFLOW SEL Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Image Speed r/min SEL250/2-1AC 2684 SEL315/2B-1AC 2776 SEL315/2A-1AC 2819 SEL355/2-1AC 2776 SEL355/4-1AC 1438 SEL400/4-1AC 1440 SEL450/4-1AC 1435 SEL500/4-1AC 1352 SEL560/4-1AC 1401 SEL630/4-1AC 1371 Airflow SFP Airflow Pressure Pa At Best Efficiency Point Overall Efficiency % FMEG N Input kw Peak Amps 3m Inlet 51 m³/s Outlet 53 W/(L/s) Breakout 29 Inlet 55 m³/s Outlet 61 W/(L/s) Breakout 40 Inlet 54 m³/s Outlet 58 W/(L/s) Breakout 37 Inlet 59 m³/s Outlet 63 W/(L/s) Breakout 42 Inlet 43 m³/s Outlet 45 W/(L/s) Breakout 26 Inlet 49 m³/s Outlet 53 W/(L/s) Breakout 39 Inlet 50 m³/s Outlet 55 W/(L/s) Breakout 44 Inlet 54 m³/s Outlet 55 W/(L/s) Breakout 46 Inlet 61 m³/s Outlet 64 W/(L/s) Breakout 54 Inlet 62 m³/s Outlet 64 W/(L/s) Breakout 53 AVAILABLE IN EC The Multiflow SEL is available in EC models on request. Please contact us for more information. Also available in AC three phase, complete with controls and supplied as a package. Please contact us for more information Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 95

96 MULTIFLOW SEL Dimensional Data Ø E F D Ø A G C B ø A B C D ø E F G Weight kg SEL250/2-1AC SEL315/2B-1AC SEL315/2A-1AC SEL355/2-1AC SEL355/4-1AC SEL400/4-1AC SEL450/4-1AC SEL500/4-1AC SEL560/4-1AC SEL630/4-1AC Dimensions are in mm. 96 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

97 MULTIFLOW SEL Accessories Transformer Controller Clamps (each) Damper Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long SEL250/2-1AC 149-TC CLAMP DAMPER JF JF JF JF4 SEL315/2B-1AC 149-TC CLAMP DAMPER JF JF JF JF4 SEL315/2A-1AC 149-TC CLAMP DAMPER JF JF JF JF4 SEL355/2-1AC 149-TC CLAMP DAMPER JF JF JF JF4 SEL355/4-1AC 149-TC CLAMP DAMPER JF JF JF JF4 SEL400/4-1AC 149-TC CLAMP DAMPER JF JF JF JF4 SEL450/4-1AC 149-TC CLAMP DENP DENP - - SEL500/4-1AC 149-TC CLAMP DENP DENP - - SEL560/4-1AC 149-TC CLAMP DENP DENP - - SEL630/4-1AC 149-TC CLAMP DENP DENP - - Panel Filter Electric Heater Battery Wiring Diagram SEL250/2-1AC FILT-P HEAT SEL315/2B-1AC FILT-P HEAT SEL315/2A-1AC FILT-P HEAT SEL355/2-1AC FILT-P HEAT SEL355/4-1AC FILT-P HEAT SEL400/4-1AC FILT-P HEAT SEL450/4-1AC FILT-P SEL500/4-1AC FILT-P SEL560/4-1AC FILT-P SEL630/4-1AC FILT-P Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 97

98 MULTIFLOW SEL Notes 98 Tel: Fax: Visit: eltaselect.com

99 HIDEAWAY SH Centrifugal Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 6 standard sizes from 100mm to 315mm. ü Air volume flow rates up to m³/s (AC) 0.37 m³/s (EC). ü Static pressures up to 690 Pa (AC) 900 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Available in AC & EC. CASING The robust 1.2mm galvanised mild steel sheet casing, is treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating. The casing is specially manufactured using integral motor mounting plates to provide additional rigidity for the casings. Each casing provides spigots to suit standard circular ducting. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. A removable lid is provided as a standard feature to facilitate ease of maintenance and cleaning. IMPELLER High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO Grade G6.3 and directly driven by the motor. MOTORS The single range of units may have either an EC or AC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability. All motors are suitable for use in ambient air conditions up to +60 C. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SH units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Bathroom and Kitchen Extract in Apartments Hotels Residential Properties Libraries Offices ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-POT Transformer Controller :149-TC Flexible Connections : 018 FLEX Clamps (each) : 018 CLAMP Damper : 018 DAMPER Silencer : 068 JF Panel Filter : 018 FILT-P Electric Heater Battery : 018 HEA Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 99

100 HIDEAWAY SH Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SH125-1ACL 2525 SH150-1ACL 2500 SH200-1ACL 2515 SH250-1ACL 2506 SH315-1ACL 2715 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps SC Amps Input kw 3m m³/s Inlet Outlet 52 W/(L/s) Breakout 41 Inlet 51 m³/s Outlet 53 W/(L/s) Breakout 44 Inlet 54 m³/s Outlet 56 W/(L/s) Breakout 49 Inlet 53 m³/s Outlet 54 W/(L/s) Breakout 48 Inlet 50 m³/s Outlet 51 W/(L/s) Breakout 46 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 100 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

101 HIDEAWAY SH Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SH100-1ECL SH125-1ECL SH150-1ECL SH200-1ECL Contol Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 58 m³/s Outlet 58 W/(L/s) Breakout 48 Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet 60 m³/s Outlet 61 W/(L/s) Breakout 53 Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet 60 m³/s Outlet 60 W/(L/s) Breakout 54 Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet 60 m³/s Outlet 63 W/(L/s) Breakout 58 Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 101

102 HIDEAWAY SH Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SH250-1ECL SH315-1ECL Contol Voltage 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 58 m³/s Outlet 60 W/(L/s) Breakout 56 Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet 53 m³/s Outlet 52 W/(L/s) Breakout 51 Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - Inlet - m³/s Outlet - W/(L/s) Breakout - A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 102 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

103 HIDEAWAY SH Dimensional Data CABLE ENTRY E G CTRS D C A F CTRS B A B C D E F G Weight kg SH SH SH SH SH SH Dimensions are in mm. Accessories Transformer Controller Flexible Connections (each) Clamps (each) Damper Panel Filter Electric Heater Battery Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram SH125-1ACL 149-TC FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF SH150-1ACL 149-TC FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF SH200-1ACL 149-TC FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF SH250-1ACL 149-TC FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF SH315-1ACL 149-TC FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF Electronic Controller Flexible Connections (each) Clamps (each) Damper Panel Filter Electric Heater Battery Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram SH100-1ECL 149-POT FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF SH125-1ECL 149-POT FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF SH150-1ECL 149-POT FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF SH200-1ECL 149-POT FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF SH250-1ECL 149-POT FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF SH315-1ECL 149-POT FLEX CLAMP DAMPER FILT-P HEAT JF JF JF JF Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 103

104 HIDEAWAY SH Notes 104 Tel: Fax: Visit: eltaselect.com

105 SINGLEFLOW SSD Centrifugal Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 8 standard sizes from 100mm to 500mm. ü Air volume flow rates up to m³/s (AC) / m³/s (EC). ü Static pressures up to 640 Pa (AC) and 930 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Available in AC & EC. CASING Robust 1.2mm galvanised mild steel sheet casing. The casing is specially manufactured using integral motor mounting plates to provide additional rigidity for the casings. Each casing provides spigots to suit standard circular ducting. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. Top & bottom access is provided as a standard feature to facilitate ease of maintenance and cleaning. IMPELLER High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit. MOTORS The single range of units may have either an EC or AC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability. All motors are suitable for use in ambient air conditions up to 60 C. QUALITY MANAGEMENT All units in the Elta range are designed and manufactured to procedures as defined in BS EN ISO 9001:2008. All SSD units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Toilets Bathrooms Hotels Schools Colleges Libraries ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-POT Transformer Controller : 149-TC Flexible Connections : 018 FLEX Clamps (each) : 018 CLAMP AV Mounts (Set of 4) : 062 SEL Damper : 018 DAMPER Silencer : 068 JF Panel Filter : 018 FILT-P Electric Heater Battery : 018 HEA Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 105

106 SINGLEFLOW SSD Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SSD125-1AC 2550 SSD150-1AC 2485 SSD200-1AC 2500 SSD250-1AC 2710 SSD315-1AC 2715 SSD400-1AC 1385 SSD500-1AC 1400 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 45 m³/s Outlet 45 W/(L/s) Breakout 38 Inlet 51 m³/s Outlet 52 W/(L/s) Breakout 39 Inlet 47 m³/s Outlet 46 W/(L/s) Breakout 41 Inlet 50 m³/s Outlet 49 W/(L/s) Breakout 43 Inlet 40 m³/s Outlet 40 W/(L/s) Breakout 33 Inlet 43 m³/s Outlet 42 W/(L/s) Breakout 39 Inlet 42 m³/s Outlet 43 W/(L/s) Breakout 47 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 106 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

107 SINGLEFLOW SSD Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SSD100-1EC SSD125-1EC SSD150-1EC SSD200-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 52 m³/s Outlet 53 W/(L/s) Breakout 47 Inlet 48 m³/s Outlet 50 W/(L/s) Breakout 44 Inlet 44 m³/s Outlet 42 W/(L/s) Breakout 38 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Inlet 52 m³/s Outlet 53 W/(L/s) Breakout 46 Inlet 49 m³/s Outlet 48 W/(L/s) Breakout 42 Inlet 49 m³/s Outlet 41 W/(L/s) Breakout 36 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Inlet 52 m³/s Outlet 54 W/(L/s) Breakout 47 Inlet 45 m³/s Outlet 51 W/(L/s) Breakout 40 Inlet 44 m³/s Outlet 47 W/(L/s) Breakout 34 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Inlet 56 m³/s Outlet 57 W/(L/s) Breakout 51 Inlet 49 m³/s Outlet 50 W/(L/s) Breakout 41 Inlet 43 m³/s Outlet 43 W/(L/s) Breakout 35 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. * At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible (less than 20dBA). Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 107

108 SINGLEFLOW SSD Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SSD250-1EC SSD315-1EC SSD400-1EC SSD500-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 51 m³/s Outlet 51 W/(L/s) Breakout 46 Inlet 47 m³/s Outlet 46 W/(L/s) Breakout 42 Inlet 36 m³/s Outlet 36 W/(L/s) Breakout 26 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Inlet 48 m³/s Outlet 50 W/(L/s) Breakout 42 Inlet 48 m³/s Outlet 47 W/(L/s) Breakout 41 Inlet 39 m³/s Outlet 35 W/(L/s) Breakout 28 Inlet *20 m³/s Outlet *20 W/(L/s) 0.15 Breakout *20 Inlet 57 m³/s Outlet 60 W/(L/s) Breakout 57 Inlet 49 m³/s Outlet 50 W/(L/s) Breakout 46 Inlet 40 m³/s Outlet 38 W/(L/s) Breakout 34 Inlet *20 m³/s Outlet *20 W/(L/s) 0.32 Breakout *20 Inlet 47 m³/s Outlet 50 W/(L/s) Breakout 51 Inlet 41 m³/s Outlet 42 W/(L/s) Breakout 44 Inlet 28 m³/s Outlet 28 W/(L/s) Breakout 30 Inlet *20 m³/s Outlet *20 W/(L/s) 0.22 Breakout *20 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. * At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible (less than 20dBA). 108 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

109 SINGLEFLOW SSD Performance, SFP & Electrical Data THREE Phase - 380V to 480V / 50Hz or 60Hz SSD500-3EC Control Voltage 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 51 m³/s Outlet 57 W/(L/s) Breakout 57 Inlet 46 m³/s Outlet 48 W/(L/s) Breakout 51 Inlet 34 m³/s Outlet 34 W/(L/s) Breakout 37 Inlet - m³/s Outlet - W/(L/s) 0.08 Breakout - A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. * At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible (less than 20dBA). Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 109

110 SINGLEFLOW SSD Dimensional Data E Ø D C A H B 74 G F J NO OF HOLES Ø K A B C D E F G H J K Weight kg SSD SSD SSD SSD SSD SSD SSD SSD Dimensions are in mm. 110 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

111 SINGLEFLOW SSD Accessories Transformer Controller Flexible Connections (each) Clamps (each) AV Mounts (set of 4) Panel Filter Electric Heater Battery SSD125-1AC 149-TC FLEX CLAMP 062-SEL FILT-P HEAT-1 SSD150-1AC 149-TC FLEX CLAMP 062-SEL FILT-P HEAT-1 SSD200-1AC 149-TC FLEX CLAMP 062-SEL FILT-P HEAT-1 SSD250-1AC 149-TC FLEX CLAMP 062-SEL FILT-P HEAT-1 SSD315-1AC 149-TC FLEX CLAMP 062-SEL FILT-P HEA1/3 SSD400-1AC 149-TC FLEX CLAMP 062-SEL FILT-P HEA1/3 SSD500-1AC 149-TC FLEX CLAMP 062-SEL FILT-P HEAT HEAT-4 Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram SSD125-1AC JF JF JF JF SSD150-1AC JF JF JF JF SSD200-1AC JF JF JF JF SSD250-1AC JF JF JF JF SSD315-1AC JF JF JF JF SSD400-1AC JF JF JF JF A SSD500-1AC Please enquire A Electronic Controller Flexible Connections (each) Clamps (each) AV Mounts (set of 4) Panel Filter Electric Heater Battery SSD100-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SSD125-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SSD150-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SSD200-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SSD250-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SSD315-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEA1/3 SSD400-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEA1/3 SSD500-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT HEAT HEAT-3 SSD500-3EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-4 Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram SSD100-1EC JF JF JF JF SSD125-1EC JF JF JF JF SSD150-1EC JF JF JF JF SSD200-1EC JF JF JF JF SSD250-1EC JF JF JF JF SSD315-1EC JF JF JF JF SSD400-1EC JF JF JF JF4 152-MOEA03K1 SSD500-1EC Please enquire 152-MOEA03K1 SSD500-3EC Please enquire 152-MOEA03K3 Tel: Fax: Visit: eltaselect.com 111

112 SINGLEFLOW SSD Notes 112 Tel: Fax: Visit: eltaselect.com

113 QUIETFLOW SQS Centrifugal Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 8 sizes from 100mm to 500mm. ü Air volume flow rates up to m³/s (AC) and m³/s (EC). ü Static pressures up to 640 Pa (AC) and 930 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Robust galvanised sheet steel casing. ü Available in AC & EC. CASING The robust 1.2mm galvanised mild steel sheet casing, is treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating. The wrap around folded casing is specially manufactured using integral motor mounting plates to provide additional rigidity for the casings. Each casing provides spigots to suit standard circular ducting. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. A removable lid is provided as a standard feature to facilitate ease of maintenance and cleaning. IMPELLER High efficiency low tonal noise backward curved centrifugal impeller. Dynamically balanced to ISO Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit. MOTORS The single range of units may have either an EC or AC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability All motors are suitable for use in ambient air conditions up to +60 C. Electrical connection shall be via an IP55 terminal box mounted on the side for easy customer connection. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SQS units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Toilets Bathrooms Hotels Schools Colleges Libraries ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-POT Transformer Controller : 149-TC Flexible Connections : 018 FLEX Clamps (each) : 018 CLAMP AV Mounts (Set of 4) : 062 SEL Damper : 018 DAMPER Silencer : 068 JF Panel Filter : 018 FILT-P Electric Heater Battery : 018 HEA Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 113

114 QUIETFLOW SQS Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SQS125-1ACL 2550 SQS150-1ACL 2485 SQS200-1ACL 2500 SQS250-1ACL 2710 SQS315-1ACL 2715 SQS400-1ACL 1385 SQS500-1ACL 1400 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 45 m³/s Outlet 45 W/(L/s) Breakout 38 Inlet 51 m³/s Outlet 52 W/(L/s) Breakout 39 Inlet 47 m³/s Outlet 46 W/(L/s) Breakout 41 Inlet 50 m³/s Outlet 49 W/(L/s) Breakout 43 Inlet 40 m³/s Outlet 40 W/(L/s) Breakout 33 Inlet 43 m³/s Outlet 42 W/(L/s) Breakout 39 Inlet 42 m³/s Outlet 43 W/(L/s) Breakout 47 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 114 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

115 QUIETFLOW SQS Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SQS100-1ECL SQS125-1ECL SQS150-1ECL SQS200-1ECL Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 51 m³/s Outlet 50 W/(L/s) Breakout 44 Inlet 48 m³/s Outlet 50 W/(L/s) Breakout 44 Inlet 44 m³/s Outlet 42 W/(L/s) Breakout 38 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Inlet 49 m³/s Outlet 54 W/(L/s) Breakout 43 Inlet 49 m³/s Outlet 48 W/(L/s) Breakout 42 Inlet 49 m³/s Outlet 41 W/(L/s) Breakout 36 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Inlet 49 m³/s Outlet 51 W/(L/s) Breakout 43 Inlet 45 m³/s Outlet 51 W/(L/s) Breakout 40 Inlet 44 m³/s Outlet 47 W/(L/s) Breakout 34 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Inlet 51 m³/s Outlet 53 W/(L/s) Breakout 44 Inlet 49 m³/s Outlet 50 W/(L/s) Breakout 41 Inlet 43 m³/s Outlet 43 W/(L/s) Breakout 35 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. * At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible (less than 20dBA). Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 115

116 QUIETFLOW SQS Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SQS250-1ECL SQS315-1ECL SQS400-1ECL SQS500-1ECL Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 49 m³/s Outlet 48 W/(L/s) Breakout 44 Inlet 47 m³/s Outlet 46 W/(L/s) Breakout 42 Inlet 36 m³/s Outlet 36 W/(L/s) Breakout 26 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Inlet 54 m³/s Outlet 53 W/(L/s) Breakout 48 Inlet 48 m³/s Outlet 47 W/(L/s) Breakout 41 Inlet 39 m³/s Outlet 35 W/(L/s) Breakout 28 Inlet *20 m³/s Outlet *20 W/(L/s) 0.15 Breakout *20 Inlet 55 m³/s Outlet 56 W/(L/s) Breakout 52 Inlet 49 m³/s Outlet 50 W/(L/s) Breakout 46 Inlet 40 m³/s Outlet 38 W/(L/s) Breakout 34 Inlet *20 m³/s Outlet *20 W/(L/s) 0.32 Breakout *20 Inlet 45 m³/s Outlet 47 W/(L/s) Breakout 49 Inlet 41 m³/s Outlet 42 W/(L/s) Breakout 44 Inlet 28 m³/s Outlet 28 W/(L/s) Breakout 30 Inlet *20 m³/s Outlet *20 W/(L/s) 0.22 Breakout *20 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. * At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible (less than 20dBA). 116 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

117 QUIETFLOW SQS Performance, SFP & Electrical Data THREE Phase - 380V to 480V / 50Hz or 60Hz SQS500-3ECL Control Voltage 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 51 m³/s Outlet 57 W/(L/s) Breakout 57 Inlet 46 m³/s Outlet 48 W/(L/s) Breakout 51 Inlet 34 m³/s Outlet 34 W/(L/s) Breakout 37 Inlet *20 m³/s Outlet *20 W/(L/s) 0.08 Breakout *20 DCV CONTROLS Demand Control Ventilation (DCV) EC options available, refer to pages for DCV information and page 144 for product information; to order add DCV to product code: SQS100-ECL with DCV order SQSDCV100-ECL. A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. * At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible (less than 20dBA). Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 117

118 G Ø D C QUIETFLOW SQS Dimensional Data E A H B 76 F J NO OF HOLES Ø K A B C D E F G H J K Weight kg SQS SQS SQS SQS SQS SQS SQS SQS Dimensions are in mm. 118 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

119 QUIETFLOW SQS Accessories Transformer Controller Flexible Connections (each) Clamps (each) AV Mounts (set of 4) Panel Filter Electric Heater Battery SQS125-1ACL 149-TC FLEX CLAMP 062-SEL FILT-P HEAT-1 SQS150-1ACL 149-TC FLEX CLAMP 062-SEL FILT-P HEAT-1 SQS200-1ACL 149-TC FLEX CLAMP 062-SEL FILT-P HEAT-1 SQS250-1ACL 149-TC FLEX CLAMP 062-SEL FILT-P HEAT-1 SQS315-1ACL 149-TC FLEX CLAMP 062-SEL FILT-P HEA1/3 SQS400-1ACL 149-TC FLEX CLAMP 062-SEL FILT-P HEA1/3 SQS500-1ACL 149-TC FLEX CLAMP 062-SEL FILT-P HEAT HEAT-4 Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram SQS125-1ACL JF JF JF JF SQS150-1ACL JF JF JF JF SQS200-1ACL JF JF JF JF SQS250-1ACL JF JF JF JF SQS315-1ACL JF JF JF JF SQS400-1ACL JF JF JF JF A SQS500-1ACL Please enquire A Electronic Controller Flexible Connections (each) Clamps (each) AV Mounts (set of 4) Panel Filter Electric Heater Battery SQS100-1ECL 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SQS125-1ECL 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SQS150-1ECL 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SQS200-1ECL 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SQS250-1ECL 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 SQS315-1ECL 149-POT FLEX CLAMP 062-SEL FILT-P HEA1/3 SQS400-1ECL 149-POT FLEX CLAMP 062-SEL FILT-P HEA1/3 SQS500-1ECL 149-POT FLEX CLAMP 062-SEL FILT-P HEAT HEAT-4 SQS500-3ECL 149-POT FLEX CLAMP 062-SEL FILT-P HEAT HEAT-4 Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram DCV Accessories Sensors SQS100-1ECL JF JF JF JF SQS125-1ECL JF JF JF JF SQS150-1ECL JF JF JF JF SQS200-1ECL JF JF JF JF SQS250-1ECL JF JF JF JF SQS315-1ECL JF JF JF JF SQS400-1ECL JF JF JF JF4 152-MOEA03K1 Can be used with all DCV products. 149-DCV-CO2 149-DCV-DPT DCV-H1 149-DCV-HRT 149-DCV-PIR 149-DCV-TRT SQS500-1ECL Please enquire 152-MOEA03K1 SQS500-3ECL Please enquire 152-MOEA03K3 Tel: Fax: Visit: eltaselect.com 119

120 QUIETFLOW SQS Notes 120 Tel: Fax: Visit: eltaselect.com

121 QUBE SQU Centrifugal Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 4 physical sizes with 5 models from 315mm to 710mm. ü Air volume flow rates up to 3.9 m³/s. ü Static pressures up to 928 Pa. ü Suitable for operating temperatures up to +50 C. ü Inverter speed controllable via 1Ph and 3Ph supply. ü Interchangeable double skinned panels. ü Available in AC. CASING Constructed from self supporting corrosion-resistant extruded aluminium section. Straight through airflow as supplied. Discharge position can be altered on site. The inlet and outlet panels incorporate circular spigots with integral U-shaped ozone and UV stable EPDM rubber seals to prevent duct leakage. Assembled with shock resistant fibreglass reinforced Polyamide PA6 corners, and 25mm thick double skinned removable panels, manufactured from pre-galvanised steel, in-filled with a non flammable mineral wool, 60kg/m³, thereby minimising breakout noise. IMPELLER A high efficiency backward curved welded steel impeller with a nonoverloading power characteristic, finished with a powder coating to RAL 5002 for greater surface protection, and dynamically balanced to G2.5 / G6.3 according to ISO1940 part 1. MOTORS Three phase multi-voltage IP55 TEFC Foot / Flange mounted IEC frame motors, wound for either (Delta) 230V/3Ph/50Hz or (Star) at 400V/3Ph/50Hz connection, suitable for speed control when used with the Eltadrive VSD range of frequency inverter controls. Motors are pre-wired to an IP55 terminal box mounted on the side, for easy customer connection. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SQU units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Kitchens Restaurants Schools Colleges Shops Sports Halls Shower Rooms Factories Industrial Units Warehousing ACCESSORIES For full accessories & controls information please visit eltaselect.com Inverter : 149-ODE Matching Flanges : 061B Flexible Connections : 063 MAN Silencer : 068 DE*P(C) Weather Hood : 064 WHC Transition Piece : 260 TP Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 121

122 QUBE SQU Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min SQU1/ SQU2/ SQU3/ SQU4/ SQU4/ Airflow SFP Airflow Static Pressure Pa. Overall Efficiency Motor % kw Peak m³/s Amps Electrical Data FLC* Amps FLC # Amps m Inlet 51 Outlet 53 W/(L/s) Breakout 36 m³/s Inlet 57 Outlet 59 W/(L/s) Breakout 42 m³/s Inlet 60 Outlet 62 W/(L/s) Breakout 45 m³/s Inlet 66 Outlet 68 W/(L/s) Breakout 51 m³/s Inlet 59 Outlet 61 W/(L/s) Breakout 44 Dimensional Data D A D A A Spigot 65mm T/BOX Spigot Ø A D Weight kg SQU1/ SQU2/ SQU3/ SQU4/ SQU4/ Dimensions are in mm. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. FLC* Amps at 230V / 1Ph / 50Hz input before a 1Ph to 3Ph Variable Speed Drive FLC# Amps at 400V / 3Ph / 50Hz input before a 3Ph to 3Ph Variable Speed Drive A variable speed drive (Eltadrive) must be installed with this fan Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 122 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

123 QUBE SQU Accessories Inverter Controller 1PH-3PH IP66 Inverter Controller 1PH-3PH IP20 Inverter Controller 3PH IP66 3PH- Inverter Controller 3PH-3PH IP20 Matching Flanges (each) SQU1/ ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 061B-0315 SQU2/ ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 061B-0500 SQU3/ ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 061B-0560 SQU4/ ODE KA4Y 149-ODE KA42 061B-0710 SQU4/ ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA42 061B-0710 Flexible Connections (each) Weather Hood Silencer 1D Unpodded Silencer 2D Unpodded Wiring Diagram SQU1/ PU SQU-WHV-A DENP DENP SQU2/ PU SQU-WHV-B DENP DENP SQU3/ PU SQU-WHV-C DENP DENP SQU4/ PU SQU-WHV-D DENP DENP SQU4/ PU SQU-WHV-D DENP DENP Fan & inverter packages available. Please contact Elta Fans for more information. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 123

124 QUBE SQU Notes 124 Tel: Fax: Visit: eltaselect.com

125 MULTIFLOW SMB Mixed Flow Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 5 standard sizes from 400mm to 650mm. ü Air volume flow rates up to 2.87m³/s. ü Static pressures up to 600 Pa. ü Suitable for operating temperatures up to +50 C. ü Available in AC. CASING The all metal casing shall be manufactured using pre-galvanised sheet steel suitably stiffened. Casings shall incorporate Ductmate flange connections at each end. Motor supports shall be of steel sheet construction, hot-dip galvanised to BS EN ISO 1461:2009 after manufacture and shall have an aerodynamic profile. IMPELLER Impellers shall be single inlet mixed flow type. Manufactured in a highly complex one-shot injection moulding process without any welded seams for maximum process reliability. Impellers are to be dynamically balanced to ISO Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit. MOTORS The single range of units may have either an EC or AC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability All motors are suitable for use in ambient air conditions up to +60 C. Electrical connection shall be via an IP55 terminal box mounted on the side for easy customer connection. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SMB units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Where higher pressure developments are required, such as: Kitchen Canopies Restaurants Lift Motor Rooms General HVAC installations ACCESSORIES For full accessories & controls information please visit eltaselect.com Transformer Controller : 149-TC Mounting Brackets (each) : 060 MFB Flexible Connections : 063 MFB Silencer : 068 MFB Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 125

126 MULTIFLOW SMB Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SMB400/4-1AC 1370 SMB450/4-1AC 1385 SMB500/4-1AC 1275 SMB550/4-1AC 1390 SMB650/4-1AC 1380 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data m³/s Inlet W/(L/s) Outlet 49 m³/s Inlet W/(L/s) Outlet 47 m³/s Inlet W/(L/s) Outlet 52 m³/s Inlet W/(L/s) Outlet 58 m³/s Inlet W/(L/s) Outlet 61 Peak Amps Input kw 3m THREE Phase - 380V to 415V / 50Hz Speed r/min Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data m³/s Inlet 46 SMB400/4-3AC W/(L/s) Outlet 50 m³/s Inlet 42 SMB450/4-3AC W/(L/s) Outlet 46 m³/s Inlet 49 SMB500/4-3AC W/(L/s) Outlet 52 m³/s Inlet 51 SMB550/4-3AC W/(L/s) Outlet 55 m³/s Inlet 57 SMB650/4-3AC W/(L/s) Outlet 61 Peak Amps Input kw 3m Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Please contact Elta Fans for SFP data. 126 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

127 MULTIFLOW SMB Dimensional Data E 4 HOLES Ø D DUCTMATE FLANGE AIR FLOW A B C A B C D E Ductmate Flange Weight kg SMB SMB SMB SMB SMB Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 127

128 MULTIFLOW SMB Accessories Transformer Controller Mounting Brackets (each) Flexible Connections (each) AV Mounts (set of 4) Splitter Silencer Wiring Diagram SMB400/4-1AC 149-TC MFB MFB MFB A SMB450/4-1AC 149-TC MFB MFB MFB A SMB500/4-1AC 149-TC MFB MFB MFB A SMB550/4-1AC 149-TC MFB MFB MFB A SMB650/4-1AC 149-TC MFB MFB MFB A Transformer Controller Mounting Brackets (each) Flexible Connections (each) AV Mounts (set of 4) Splitter Silencer Wiring Diagram SMB400/4-3AC 149-TC MFB MFB MFB A SMB450/4-3AC 149-TC MFB MFB MFB A SMB500/4-3AC 149-TC MFB MFB MFB A SMB550/4-3AC 149-TC MFB MFB MFB A SMB650/4-3AC 149-TC MFB MFB MFB A 128 Tel: Fax: Visit: eltaselect.com

129 MULTIFLOW SMB Notes Tel: Fax: Visit: eltaselect.com 129

130 TWINFLOW STD Centrifugal Twin Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 7 standard sizes from 125mm to 500mm. ü Air volume flow rates up to 1.89 m³/s. ü Static pressures up to 1028 Pa. ü Suitable for operating temperatures up to +60 C. ü Available in EC. CASING Robust 1.2mm galvanised mild steel sheet casing. The casing is specially manufactured using integral motor mounting plates to provide additional rigidity for the casings. Each casing provides spigots to suit standard circular ducting. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. Top & bottom access is provided as a standard feature to facilitate ease of maintenance and cleaning. IMPELLER High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit. MOTORS The twin range of units have an EC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability All motors are suitable for use in ambient air conditions up to 60 C. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All STD units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Toilets Bathrooms Hotels Schools Colleges Libraries ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-POT Flexible Connections : 018 FLEX Clamps (each) : 018 CLAMP AV Mounts (Set of 4) : 062 SEL Damper : 018 DAMPER Silencer : 068 JF Panel Filter : 018 FILT-P Electric Heater Battery : 018 HEA ACO Panel : 149-ACO 130 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

131 TWINFLOW STD Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz STD125-1EC STD150-1EC STD200-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa m³/s Overall Efficiency % Motor Electrical Data Peak Amps Input kw m Inlet 52 Outlet 54 W/(L/s) Breakout 45 m³/s Inlet 48 Outlet 48 W/(L/s) Breakout 42 m³/s Inlet 40 Outlet 38 W/(L/s) Breakout 42 m³/s Inlet *20 Outlet *20 W/(L/s) Breakout *20 m³/s Inlet 53 Outlet 53 W/(L/s) Breakout 46 m³/s Inlet 47 Outlet 50 W/(L/s) Breakout 43 m³/s Inlet 38 Outlet 43 W/(L/s) Breakout 43 m³/s Inlet *20 Outlet *20 W/(L/s) 0.16 Breakout *20 m³/s Inlet 57 Outlet 57 W/(L/s) Breakout 51 m³/s Inlet 50 Outlet 51 W/(L/s) Breakout 45 m³/s Inlet 40 Outlet 41 W/(L/s) Breakout 35 m³/s Inlet *20 Outlet *20 W/(L/s) Breakout *20 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Please contact Elta Fans for full sound data. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 131

132 TWINFLOW STD Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz STD250-1EC STD315-1EC STD400-1EC ST500-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 52 m³/s Outlet 52 W/(L/s) Breakout 47 Inlet 47 m³/s Outlet 48 W/(L/s) Breakout 42 Inlet 36 m³/s Outlet 35 W/(L/s) Breakout 27 Inlet *20 m³/s Outlet *20 W/(L/s) 0.08 Breakout *20 Inlet 54 m³/s Outlet 53 W/(L/s) Breakout 50 Inlet 43 m³/s Outlet 43 W/(L/s) Breakout 40 Inlet 36 m³/s Outlet 32 W/(L/s) Breakout 28 Inlet *20 m³/s Outlet *20 W/(L/s) 0.16 Breakout *20 Inlet 59 m³/s Outlet 62 W/(L/s) Breakout 55 Inlet 51 m³/s Outlet 52 W/(L/s) Breakout 47 Inlet 40 m³/s Outlet 41 W/(L/s) Breakout 34 Inlet *20 m³/s Outlet *20 W/(L/s) 0.04 Breakout *20 Inlet 51 m³/s Outlet 54 W/(L/s) Breakout 53 Inlet 45 m³/s Outlet 47 W/(L/s) Breakout 44 Inlet 32 m³/s Outlet 32 W/(L/s) Breakout 30 Inlet *20 m³/s Outlet *20 W/(L/s) 0.02 Breakout *20 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible. (less than 20dBA) 132 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

133 TWINFLOW STD Performance, SFP & Electrical Data THREE Phase - 380V to 480V / 50Hz or 60Hz STD500-3EC Control Voltage 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 58 m³/s Outlet 60 W/(L/s) Breakout 57 Inlet 51 m³/s Outlet 52 W/(L/s) Breakout 50 Inlet 37 m³/s Outlet 38 W/(L/s) Breakout 36 Inlet 20 m³/s Outlet 20 W/(L/s) 0.08 Breakout 20 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Please contact Elta Fans for full sound data. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 133

134 TWINFLOW STD Dimensional Data E A H G ØD C B 74 F J NO OF HOLES Ø K A B C D E F G H J K Weight kg STD STD STD STD STD STD STD Dimensions are in mm. 134 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

135 TWINFLOW STD Accessories Electronic Controller Flexible Connections (each) Clamps (each) AV Mounts (set of 4) Panel Filter Electric Heater Battery STD100-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 STD125-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 STD150-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 STD200-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 STD250-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT-1 STD315-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEA1/3 STD400-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEA1/3 STD500-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT HEAT-4 STD500-3EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT HEAT-4 ACOP Standard Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram STD100-1EC 149-ACO14E JF JF JF JF STD125-1EC 149-ACO14E JF JF JF JF STD150-1EC 149-ACO14E JF JF JF JF STD200-1EC 149-ACO14E JF JF JF JF STD250-1EC 149-ACO14E JF JF JF JF STD315-1EC 149-ACO14E JF JF JF JF STD400-1EC 149-ACO14E JF JF JF JF STD500-1EC 149-ACO14E Please enquire STD500-3EC 149-ACO14E Please enquire 152-2MOEA03K3 Tel: Fax: Visit: eltaselect.com 135

136 TWINFLOW STD Notes 136 Tel: Fax: Visit: eltaselect.com

137 QUIETFLOW SQT Centrifugal Twin Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 7 standard sizes from 125mm to 500mm. ü Air volume flow rates up to m³/s. ü Static pressures up to 1029 Pa. ü Suitable for operating temperatures up to +60 C. ü Available in EC. CASING The robust 1.2mm galvanised mild steel sheet casing, is treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating. The wrap around folded casing is specially manufactured using integral motor mounting plates to provide additional rigidity for the casings. Each casing provides spigots to suit standard circular ducting. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. A removable lid is provided as a standard feature to facilitate ease of maintenance and cleaning. IMPELLER High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit. MOTORS The twin range of units have an EC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability All motors are suitable for use in ambient air conditions up to +60 C. Electrical connection shall be via an IP55 terminal box mounted on the side for easy customer connection. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SQT units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Toilets and Bathrooms Hotels Kitchens Residential Offices Libraries ACCESSORIES For full accessories & controls information please visit eltaselect.com ACO Panel : 149-ACO Electronic Controller :149-POT Flexible Connections : 018 FLEX Clamps (each) : 018 CLAMP AV Mounts (Set of 4) : 062 SEL Damper : 018 DAMPER Silencer : 068 JF Panel Filter : 018 FILT-P Electric Heater Battery : 018 HEA Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 137

138 QUIETFLOW SQT Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SQT125-1ECL SQT150-1ECL SQT200-1ECL Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 50 m³/s Outlet 52 W/(L/s) Breakout 42 Inlet 48 m³/s Outlet 48 W/(L/s) Breakout 42 Inlet 40 m³/s Outlet 38 W/(L/s) Breakout 42 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 Inlet 50 m³/s Outlet 50 W/(L/s) Breakout 43 Inlet 47 m³/s Outlet 50 W/(L/s) Breakout 43 Inlet 38 m³/s Outlet 43 W/(L/s) Breakout 43 Inlet *20 m³/s Outlet *20 W/(L/s) 0.16 Breakout *20 Inlet 54 m³/s Outlet 54 W/(L/s) Breakout 48 Inlet 50 m³/s Outlet 51 W/(L/s) Breakout 45 Inlet 40 m³/s Outlet 41 W/(L/s) Breakout 35 Inlet *20 m³/s Outlet *20 W/(L/s) Breakout *20 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 138 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

139 QUIETFLOW SQT Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SQT250-1ECL SQT315-1ECL SQT400-1ECL SQT500-1ECL Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 50 m³/s Outlet 50 W/(L/s) Breakout 44 Inlet 47 m³/s Outlet 48 W/(L/s) Breakout 42 Inlet 36 m³/s Outlet 35 W/(L/s) Breakout 27 Inlet *20 m³/s Outlet *20 W/(L/s) 0.08 Breakout *20 Inlet 51 m³/s Outlet 51 W/(L/s) Breakout 47 Inlet 43 m³/s Outlet 43 W/(L/s) Breakout 40 Inlet 36 m³/s Outlet 32 W/(L/s) Breakout 28 Inlet *20 m³/s Outlet *20 W/(L/s) 0.16 Breakout *20 Inlet 58 m³/s Outlet 57 W/(L/s) Breakout 53 Inlet 51 m³/s Outlet 52 W/(L/s) Breakout 47 Inlet 40 m³/s Outlet 41 W/(L/s) Breakout 34 Inlet *20 m³/s Outlet *20 W/(L/s) 0.04 Breakout *20 Inlet 51 m³/s Outlet 51 W/(L/s) Breakout 50 Inlet 45 m³/s Outlet 47 W/(L/s) Breakout 44 Inlet 32 m³/s Outlet 32 W/(L/s) Breakout 30 Inlet *20 m³/s Outlet *20 W/(L/s) 0.02 Breakout *20 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 139

140 QUIETFLOW SQT Performance, SFP & Electrical Data THREE Phase - 380V to 480V / 50Hz or 60Hz SQT500-3ECL Control Voltage 10V 8V 5V 2V Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m Inlet 58 m³/s Outlet 58 W/(L/s) Breakout 56 Inlet 51 m³/s Outlet 52 W/(L/s) Breakout 50 Inlet 37 m³/s Outlet 38 W/(L/s) Breakout 36 Inlet *20 m³/s Outlet *20 W/(L/s) 0.08 Breakout *20 DCV CONTROLS Demand Control Ventilation (DCV) EC options available, refer to pages for DCV information and page 144 for product information; to order add DCV to product code: SQT100-ECL with DCV order SQTDCV100-ECL. A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. * At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible (less than 20dBA). 140 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

141 QUIETFLOW SQT Dimensional Data E Ø D C A H B 74 G F J NO OF HOLES Ø K A B C D E F G H J K Weight kg SQT SQT SQT SQT SQT SQT SQT Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 141

142 QUIETFLOW SQT Accessories Electronic Controller Flexible Connections (each) Clamps (each) AV Mounts (set of 4) Panel Filter Electric Heater Battery ACOP Standard SQT100-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT ACO14E SQT125-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT ACO14E SQT150-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT ACO14E SQT200-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT ACO14E SQT250-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEAT ACO14E SQT315-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEA1/3 149-ACO14E SQT400-1EC 149-POT FLEX CLAMP 062-SEL FILT-P HEA1/3 149-ACO14E HEAT-3 SQT500-1EC 149-POT FLEX CLAMP 062-SEL FILT-P 149-ACO14E HEAT HEAT-3 SQT500-3EC 149-POT FLEX CLAMP 062-SEL FILT-P 149-ACO14E HEAT-4 Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram SQT100-1EC JF JF JF JF SQT125-1EC JF JF JF JF SQT150-1EC JF JF JF JF SQT200-1EC JF JF JF JF SQT250-1EC JF JF JF JF SQT315-1EC JF JF JF JF SQT400-1EC JF JF JF JF SQT500-1EC Please enquire SQT500-3EC Please enquire 152-2MOEA03K3 DCV Accessories Sensors Can be used with all DCV products. 149-DCV-CO2 149-DCV-DPT DCV-H1 149-DCV-HRT 149-DCV-PIR 149-DCV-TRT 142 Tel: Fax: Visit: eltaselect.com

143 QUIETFLOW SQT Notes Tel: Fax: Visit: eltaselect.com 143

144 QUIETFLOW SQS DCV Centrifugal Box Fan OVERVIEW The Quietflow SQS...EC DCV incorporates the BAT (Best Available Technology) Vpro/ZAvBlue backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of acoustically treated single in-line fans are suitable for Demand Control Ventilation via matching sensors. Refer to Quietflow SQS on pages for Performance & Electrical Data. For DCV information refer to pages QUICK FACTS ü 8 sizes from 100mm to 500mm. ü Air volume flow rates up to m³/s (EC). ü Static pressures up to 930 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Robust galvanised sheet steel casing. ü Available in EC. QUIETFLOW SQT DCV Centrifugal Box Fan OVERVIEW The Quietflow SQT DCV...ECL incorporates the BAT (Best Available Technology) Vpro/ZAvBlue backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of acoustically treated in-line centrifugal twin fans are suitable for Demand Control Ventilation via matching sensors. Refer to Quietflow SQT on page for Performance & Electrical Data. For DCV information refer to pages QUICK FACTS ü 7 standard sizes from 125mm to 500mm. ü Air volume flow rates up to m³/s. ü Static pressures up to 1029 Pa. ü Suitable for operating temperatures up to +60 C. ü Available in EC. 144 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

145 Roof Tel: Fax: Visit: eltaselect.com 145

146 146 Tel: Fax: Visit: eltaselect.com

147 HERITAGE SCH Roof Mounted Vertical Discharge Centrifugal Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 5 standard sizes from 315mm to 500mm. ü Air volume flow rates up to m³/s. ü Static pressures up to 6 00 Pa. ü Suitable for operating temperatures up to +50 C. ü Can be mounted at angles up to 30. ü Available in AC. CASING MOTORS TYPICAL APPLICATIONS Roof The all metal fan casing provides a long lasting and robust construction. The casings are manufactured from pregalvanised sheet steel. The wind band shall incorporate quick-release toggle clamps to provide easy access for cleaning and maintenance. All SCH units can be mounted at angles up to 30. IMPELLER Aerodynamically designed backward curved centrifugal impellers constructed in aluminium or galvanised sheet steel. Impellers are balanced to ISO Grade G6.3. Motors shall be external rotor motor, with sealed for life ball bearings. Motors shall be minimum IP44 protected and minimum Class B insulation. All units are suitable for operating temperatures up to +50 C. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SCH units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). Industrial Commercial Kitchens and Catering Hospitals Bakeries Forges and Foundries ACCESSORIES For full accessories & controls information please visit eltaselect.com Transformer Controller : 149-TC Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 147

148 HERITAGE SCH Performance & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min SCH315/ SCH350/ SCH400/ SCH450/ Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps SC Amps Input kw 3m m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - THREE Phase - 380V to 415V / 50Hz Speed r/min SCH315/ SCH350/ SCH400/ SCH450/4-3 SCH500/ Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps SC Amps Input kw 3m m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet m³/s Inlet - W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet m³/s Inlet - W/(L/s) Outlet - Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 148 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

149 HERITAGE SCH Dimensional Data A D B E F C A B C D E F Weight kg SCH SCH SCH SCH SCH /57* Dimensions are in mm. *The higher weight shown applies to the /4-2 & /4-3 versions. Accessories Transformer Controller SCH315/4-2 SCH350/4-2 SCH400/4-2 SCH450/ TC TC TC TC18 Transformer Controller SCH315/4-3 SCH350/4-3 SCH400/4-3 SCH450/4-3 SCH500/ TC TC TC TC TC35 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 149

150 HERITAGE SCH Notes 150 Tel: Fax: Visit: eltaselect.com

151 HERITAGE SCHT Roof Mounted Vertical Discharge Centrifugal Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 5 standard sizes from 400mm to 630mm. ü Air volume flow rates up to m³/s. ü Static pressures up to 1000 Pa. ü Suitable for operating temperatures up to +50 C. ü Can be mounted at angles up to 15. ü Available in AC. CASING The all metal cowls shall provide a long lasting and robust construction, manufactured from pressed galvanised sheet steel and powder coated after forming. The wind band shall incorporate toggle clamps to provide easy access for cleaning and maintenance. All SCHT units can be mounted at angles up to 15. IMPELLER Aerodynamically designed backward curved centrifugal impellers constructed in aluminium or galvanised sheet steel. Impellers are balanced to ISO Grade G6.3. MOTORS Motors are to be foot mounted totally enclosed metric type to IP55, with sealed for life bearings, standard industrial paint finish and Class F insulation to EN , suitable for operating temperatures up to +50 C. Motors are to be wired via a weatherproofed cable to an IP55 protected terminal box. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SCHT units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Industrial Commercial Kitchens and Catering Hospitals Bakeries Forges and Foundries ACCESSORIES For full accessories & controls information please visit eltaselect.com Inverter : 149-ODE Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 151

152 HERITAGE SCHT Performance & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min SCHT400/ SCHT450/ SCHT500/ SCHT560/ SCHT630/ Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 152 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

153 HERITAGE SCHT Dimensional Data A D B E F C A B C D E F Weight kg 4 Pole SCHT SCHT SCHT SCHT SCHT Dimensions are in mm. Accessories Inverter Controller 1PH-3PH IP66 Inverter Controller 1PH-3PH IP20 Inverter Controller 3PH-3PH IP66 Inverter Controller 3PH-3PH IP20 SCHT400/ ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCHT450/ ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCHT500/ ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 SCHT560/ ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA42 SCHT630/ ODE KA4Y 149-ODE KA42 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 153

154 HERITAGE SCHT Notes 154 Tel: Fax: Visit: eltaselect.com

155 SINGLEFLOW SSDR Roof Mounted Direct Drive Centrifugal Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 5 standard sizes from 200mm to 500mm (7 models). ü Air volume flow rates up to m³/s (AC) / m³/s (EC). ü Static pressures up to 600 Pa (AC) / 950 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Available in AC and EC. CASING The unit casing shall be manufactured from 1.2mm thick natural finish Aluzinc. The casing shall be designed so as to minimise vibration and shall incorporate a louvered air discharge guarded against bird ingress. Drain points shall also be provided. Each casing provides an inlet spigot to suit standard circular ducting. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. Top access panels shall be provided for ease of servicing. IMPELLER High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit. MOTORS The Twin range of units may have either an EC or AC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability. All motors are suitable for use in ambient air conditions up to +60 C. QUALITY MANAGEMENT All units in the Elta range are designed and manufactured to procedures as defined in BS EN ISO 9001:2008. They are also tested in accordance with BS848 Part (sound performance) and ISO 5801:2007 (airside performance). TYPICAL APPLICATIONS Industrial Building Banks Hospitals Offices Hotels and Shopping Malls ACCESSORIES For full accessories & controls information please visit eltaselect.com Electronic Controller :149-POT Transformer Controller : 149-TC Flexible Connections : 018 FLEX Clamps (each) : 018 CLAMP Silencer : 068 JF Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 155

156 SINGLEFLOW SSDR Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz Speed r/min SSDR200-1AC 2555 SSDR250L-1AC 2570 SSDR250H-1AC 2520 Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 42 m³/s Inlet W/(L/s) Outlet 47 m³/s Inlet W/(L/s) Outlet 49 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 156 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

157 SINGLEFLOW SSDR Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SSDR200-1EC SSDR250H-1EC SSDR250L-1EC SSDR315-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 50 m³/s Inlet W/(L/s) Outlet 48 m³/s Inlet W/(L/s) Outlet 40 m³/s Inlet W/(L/s) Outlet *20 m³/s Inlet W/(L/s) Outlet 49 m³/s Inlet W/(L/s) Outlet 45 m³/s Inlet W/(L/s) Outlet 34 m³/s Inlet * W/(L/s) Outlet *20 m³/s Inlet W/(L/s) Outlet 54 m³/s Inlet W/(L/s) Outlet 49 m³/s Inlet W/(L/s) Outlet 39 m³/s Inlet * W/(L/s) Outlet *20 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 47 m³/s Inlet W/(L/s) Outlet 34 m³/s Inlet * W/(L/s) 0.17 Outlet *20 A variable speed drive is integrated within the fan. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 157

158 SINGLEFLOW SSDR Performance, SFP & Electrical Data SINGLE Phase - 200V to 277V / 50Hz or 60Hz SSDR400-1EC SSDR500-1EC Control Voltage 10V 8V 5V 2V 10V 8V 5V 2V Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m m³/s Inlet W/(L/s) Outlet 59 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 41 m³/s Inlet W/(L/s) 0.34 Outlet 24 m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet 47 m³/s Inlet W/(L/s) Outlet 38 m³/s Inlet W/(L/s) Outlet 20 THREE Phase - 380V to 415V / 50Hz Control Voltage Speed r/min SSDR500-3EC 10V 1799 SSDR500-3EC 8V 1455 SSDR500-3EC 5V 874 SSDR500-3EC 2V 292 Airflow Airflow Static Pressure Pa FMEG N Motor Electrical Data Peak Amps Output kw 3m m³/s Inlet W/(L/s) Outlet 61 m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet 42 m³/s Inlet W/(L/s) 0.09 Outlet 23 DCV CONTROLS Controllers Demand Control Ventilation (DCV) EC options available, refer to pages for DCV information and page 169 for product information; to order add DCV to product code: SSDR200-EC with DCV order SSDRDCV200-EC. Humidity PIR Pressure CO 2 Temperature Controller Elta Drive Single PH 3PH SmartStart Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. A variable speed drive is integrated within the fan. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. 158 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

159 SINGLEFLOW SSDR Dimensional Data C E Ø D F 76 A B A B C D E F Weight kg SSDR SSDR SSDR SSDR SSDR Dimensions are in mm. Accessories Transformer Controller Flexible Connections (each) Clamps (each) Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long SSDR200-1AC 149-TC FLEX CLAMP JF JF JF JF4 SSDR250L-1AC 149-TC FLEX CLAMP JF JF JF JF4 SSDR250H-1AC 149-TC FLEX CLAMP JF JF JF JF4 Electronic Controller Flexible Connections (each) Clamps (each) Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long SSDR200-1EC 149-POT FLEX CLAMP JF JF JF JF4 SSDR250H-1EC 149-POT FLEX CLAMP JF JF JF JF4 SSDR250L-1EC 149-POT FLEX CLAMP JF JF JF JF4 SSDR315-1EC 149-POT FLEX CLAMP JF JF JF JF4 SSDR400-1EC 149-POT FLEX CLAMP JF JF JF JF4 SSDR500-1EC 149-POT FLEX CLAMP Please enquire SSDR500-3EC 149-POT FLEX CLAMP Please enquire DCV Accessories Sensors Can be used with all DCV products. 149-DCV-CO2 149-DCV-DPT DCV-H1 149-DCV-HRT 149-DCV-PIR 149-DCV-TRT Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 159

160 SINGLEFLOW SSDR Notes 160 Tel: Fax: Visit: eltaselect.com

161 TWINFLOW STDR Direct Drive Twin Centrifugal Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 5 standard sizes from 200mm to 500mm. ü Air volume flow rates up to 0.23 m³/s (AC) / 1.65 m³/s (EC). ü Static pressures up to 500 Pa (AC) / 960 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Extensive range of stock available. ü Available in AC and EC. CASING The unit casing shall be manufactured from 1.2mm thick natural finish Aluzinc. The casing shall be designed so as to minimise vibration and shall incorporate a louvered air discharge guarded against bird ingress. Drain points shall also be provided. Each casing provides an inlet spigot to suit standard circular ducting. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. Top access panels shall be provided for ease of servicing. IMPELLER High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit. MOTORS The Twin range of units may have either an EC or AC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability. All motors are suitable for use in ambient air conditions up to +60 C. QUALITY MANAGEMENT All units in the Elta range are designed and manufactured to procedures as defined in BS EN ISO 9001:2008. They are also tested in accordance with BS848 Part (sound performance) and ISO 5801:2007 (airside performance). TYPICAL APPLICATIONS Industrial Building Banks Hospitals Offices Hotels and Shopping Malls ACCESSORIES For full accessories & controls information please visit eltaselect.com ACO Panel : 149-ACO Electronic Controller :149-POT Transformer Controller : 149-TC Flexible Connections : 018 FLEX Clamps (each) : 018 CLAMP Silencer : 068 JF Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 161

162 TWINFLOW STDR Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m STDR200-1AC 2490 STDR250L-1AC 2506 m³/s Inlet W/(L/s) Outlet 47 m³/s Inlet W/(L/s) Outlet 55 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. 162 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

163 TWINFLOW STDR Performance, SFP & Electrical Data EC SINGLE Phase - 200V to 277V / 50Hz or 60Hz Control Voltage Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m STDR200-1EC STDR250H-1EC STDR250L-1EC STDR315-1EC STDR400-1EC 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V 10V 8V 5V 2V m³/s Inlet W/(L/s) Outlet 57 m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet 44 m³/s Inlet W/(L/s) 0.40 Outlet 22 m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet 50 m³/s Inlet W/(L/s) Outlet 37 m³/s Inlet * W/(L/s) 0.27 Outlet *20 m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet 55 m³/s Inlet W/(L/s) Outlet 44 m³/s Inlet W/(L/s) Outlet 30 m³/s Inlet W/(L/s) Outlet 57 m³/s Inlet W/(L/s) Outlet 50 m³/s Inlet W/(L/s) Outlet 38 m³/s Inlet * W/(L/s) 0.22 Outlet *20 m³/s Inlet W/(L/s) Outlet 65 m³/s Inlet W/(L/s) Outlet 59 m³/s Inlet W/(L/s) Outlet 43 m³/s Inlet * W/(L/s) 0.04 Outlet 22 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the fan. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 163

164 TWINFLOW STDR Performance, SFP & Electrical Data EC SINGLE Phase - 200V to 277V / 50Hz or 60Hz Control Voltage Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m STDR500-1EC 10V 8V 5V 2V m³/s Inlet W/(L/s) Outlet 59 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 39 m³/s Inlet * W/(L/s) 0.03 Outlet *20 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the fan. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. 164 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

165 TWINFLOW STDR Performance, SFP & Electrical Data EC THREE Phase - 380V to 480V / 50Hz or 60Hz Control Voltage Airflow Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data Peak Amps Input kw 3m STDR500-3EC 10V 8V 5V 2V m³/s Inlet W/(L/s) Outlet 68 m³/s Inlet W/(L/s) Outlet 60 m³/s Inlet W/(L/s) Outlet 46 m³/s Inlet * W/(L/s) 0.13 Outlet 22 DCV CONTROLS Demand Control Ventilation (DCV) EC options available, refer to pages for DCV information and page 169 for product information; to order add DCV to product code: SSDR200-EC with DCV order SSDRDCV200-EC. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the fan. *At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 165

166 TWINFLOW STDR Dimensional Data C 76 E A Ø D B F A B C D E F Weight kg STDR STDR250L STDR250H STDR STDR STDR Dimensions are in mm. 166 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

167 TWINFLOW STDR Accessories ACO Panel Transformer Controller Flexible Connections (each) Clamps (each) Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram STDR200-1AC 149-ACO TC FLEX CLAMP JF JF JF JF STDR250L-1AC 149-ACO TC FLEX CLAMP JF JF JF JF Electronic Controller ACO Panel Flexible Connections (each) Clamps (each) Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram STDR200-1EC 149-POT ACO14E FLEX CLAMP JF JF JF JF STDR250H-1EC 149-POT ACO14E FLEX CLAMP JF JF JF JF STDR250L-1EC 149-POT ACO14E FLEX CLAMP JF JF JF JF STDR315-1EC 149-POT ACO14E FLEX CLAMP JF JF JF JF STDR400-1EC 149-POT ACO1/B FLEX CLAMP JF JF JF JF STDR500-1EC 149-POT ACO1/B FLEX CLAMP Please enquire Electronic Controller ACO Panel Flexible Connections (each) Clamps (each) Silencer 300mm Long Silencer 600mm Long Silencer 900mm Long Silencer 1200mm Long Wiring Diagram STDR500-3EC 149-POT ACO3/B FLEX CLAMP Please enquire MOEA03K3 Tel: Fax: Visit: eltaselect.com 167

168 TWINFLOW STDR Notes 168 Tel: Fax: Visit: eltaselect.com

169 SINGLEFLOW SSDR DCV Roof Mounted Direct Drive Centrifugal Fan Refer to Singleflow SSDR on pages for Performance & Electrical Data. For DCV information refer to pages QUICK FACTS OVERVIEW The Singleflow SSDR DCV...EC incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor.the range of single roof fans are suitable for external mounting, manufactured in Aluzinc with a natural finish. ü 5 standard sizes from 200mm to 500mm (7 models). ü Air volume flow rates up to 3.84 m³/s (EC). ü Static pressures up to 1300 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Available in EC. TWINFLOW STDR DCV Roof Mounted Direct Drive Twin Centrifugal Fan OVERVIEW The Twinflow STDR DCV...EC incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of twin roof fans are suitable for external mounting, manufactured in Aluzinc with a natural finish. Refer to Twinflow STDR on pages for Performance & Electrical Data. For DCV information refer to pages QUICK FACTS ü 5 standard sizes from 200mm to 500mm. ü Air volume flow rates up to 1.65 m³/s (EC). ü Static pressures up to 960 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Extensive range of stock available. ü Available in EC. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 169

170 MINIFLOW SMF Horizontal Roof Cowl For full detailed information on Accessories please visit eltaselect.com. QUICK FACTS ü UV Stabilised ü Maintenance Free ü Up to 30 roof pitch ügoose Wing Grey (BS 00-A-05) CASING The top cowl and fan support housing shall be manufactured from UVstabilised plastic, finished in goose wing grey (BS 00-A-05). QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. TYPICAL APPLICATIONS Changing Rooms Toilets Bathrooms Shower Rooms 170 Tel: Fax: Visit: eltaselect.com

171 MINIFLOW SMF Cowl Pressure Drop Curve SMF13 SMF20/ Pressure Drop, Pa Vol m /s Determine pressure loss against required flow rate and add pressure loss value to system design pressure, verify that fan selection can accommodate extra pressure loss. Original design: flow rate (m³/s) and pressure (Pa), with cowl becomes flow rate (m³/s) and (pressure (Pa) + pressure loss (Pa) from curve). Dimensional Data A D C E F B A B C D E F Weight kg SMF SMF20/ Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 171

172 MINIFLOW SMF Notes 172 Tel: Fax: Visit: eltaselect.com

173 SKYFLOW SSR Horizontal Roof Cowl For full detailed information on Accessories please visit eltaselect.com. QUICK FACTS ü UV Stabilised ü Maintenance Free ü Up to 30 roof pitch ü Goose Wing Grey (BS 00-A-05) CASING The top cowl and fan support housing shall be manufactured from UV stabilised GRP finished in goose wing grey (BS 00-A-05). QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. TYPICAL APPLICATIONS Libraries Hospitals Offices Banks Small Industrial Units Retail Parks ACCESSORIES For full accessories & controls information please visit eltaselect.com SSR (c/w Bird Guard) SSR (c/w Bird Guard & Shutters) Silencer : 068 SFDS Back Draught Shutter : 039 SFSV Purlin Box : 039B PB Soaker Sheet : 039 SP Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 173

174 SKYFLOW SSR Cool Pressure Drop Curve SSR25 SSR31/35 SSR40/45 SSR50/56 SSR63/71 SSR80 Pressure Drop, Pa Vol m /s Determine pressure loss against required flow rate and add pressure loss value to system design pressure, verify that fan selection can accommodate extra pressure loss. Original design: flow rate (m³/s) and pressure (Pa), with cowl becomes flow rate (m³/s) and (pressure (Pa) + pressure loss (Pa) from curve). 174 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

175 SKYFLOW SSR Dimensional Data 1 Purlin Mounted PURLIN MOUNTING UNIT PURLIN MOUNTING UNIT 1 A A Curb Mounted CURB MOUNTING UNIT CURB MOUNTING UNIT C C D F HEIGHT PURLIN BOX D F HEIGHT PURLIN BOX E B INSIDE SECTION A-A J TYP CRS K CRS E N N B INSIDE L L STANDARD PURLIN BOX STANDARD PURLIN BOX SECTION A-A IS SUITABLE FOR ROOM IS SUITABLE FOR ROOM SECTION B-B SECTION B-B THICKNESS OF 50-75mmTHICKNESS OF 50-75mm SECURE UNIT TO HARDWOOD SECURE UNIT TO HARDWOOD SILL WITH M10 COACH BOLTS SILL WITH M10 COACH BOLTS (NOT SUPPLIED BY ELTA FANS) (NOT SUPPLIED BY ELTA FANS) J TYP CRS PURLIN BOX SECURED TOPURLIN BOX SECURED TO TRIMMERS WITH M10 TRIMMERS WITH M10 K CRS LINDAPTERS (NOT SUPPLIED LINDAPTERS (NOT SUPPLIED BY ELTA FANS) BY ELTA FANS) M K CRS M K CRS PRODUCT CODE A B C D E SSR SSR SSR350 SSR SSR450 SSR SSR560 SSR SSR710 A A A G BETWEEN TRIMMERS A G BETWEEN TRIMMERS B B B B H TYP CRS H TYP CRS NOTE: SIZE 250 PURLIN BOXES ARE PARALLEL SIDED A B C D E F G H J K L M N Weight kg SSR SSR31/ SSR40/ SSR50/ SSR63/ SSR Dimensions are in mm. Accessories (c/w Bird Guard) (c/w Bird Guard & Shutters) Backdraught Shutter Purlin Box Soaker Sheet Drop in Silencer 600mm Long Drop in Silencer 900mm Long Drop in Silencer 1200mm Long SSR25 SSR25B SSR25BS 039-SFSV B-PB SP SFDS-0600-E 068-SFDS-0900-E 068-SFDS-1200-E SSR31/35 SSR31/35B SSR31/35BS 039-SFSV-31/35 039B-PB31/ SP31/ SFDS-0600-A 068-SFDS-0900-A 068-SFDS-1200-A SSR40/45 SSR40/45B SSR40/45BS 039-SFSV-40/45 039B-PB40/ SP40/ SFDS-0600-B 068-SFDS-0900-B 068-SFDS-1200-B SSR50/56 SSR50/56B SSR50/56BS 039-SFSV-50/56 039B-PB50/ SP50/ SFDS-0600-C 068-SFDS-0900-C 068-SFDS-1200-C SSR63/71 SSR63/71B SSR63/71BS 039-SFSV-63/71 039B-PB63/ SP63/ SFDS-0600-D 068-SFDS-0900-D 068-SFDS-1200-D SSR80 SSR80B SSR80BS 039-SFSV B-PB SP SFDS-0600-F 068-SFDS-0900-F 068-SFDS-1200-F Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 175

176 SKYFLOW SSR Notes 176 Tel: Fax: Visit: eltaselect.com

177 SKYFLOW SSFV Vertical Roof Cowl For full detailed information on Accessories please visit eltaselect.com. QUICK FACTS ü UV Stabilised ü Maintenance Free ü Up to 30 roof pitch ü Goose Wing Grey (BS 00-A-05) ü Complete with Shutter CASING The top cowl and fan support housing shall be manufactured from UV stabilised GRP finished in goose wing grey (BS 00-A-05). QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. TYPICAL APPLICATIONS Industrial Units Hospitals Workshops ACCESSORIES For full accessories & controls information please visit eltaselect.com Purlin Box : 039B PB Soaker Sheet : 039 SP Silencer : 068 SFDS Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 177

178 SKYFLOW SSFV Cowl Pressure Drop Curve SSFV31/35 SSFV40/45 SSFV50/56 SSFV63/ Vol m /s Determine pressure loss against required flow rate and add pressure loss value to system design pressure, verify that fan selection can accommodate extra pressure loss. Original design: flow rate (m³/s) and pressure (Pa), with cowl becomes flow rate (m³/s) and (pressure (Pa) + pressure loss (Pa) from curve). 178 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

179 SKYFLOW SSFV Dimensional Data Purlin Mounted Curb Mounted Ø A Ø A C C D F HEIGHT PURLIN BOX D F HEIGHT PURLIN BOX E B INSIDE SECTION A-A E B INSIDE STANDARD PURLIN BOX SECTION IS A-A SUITABLE FOR ROOM THICKNESS OF 50-75mm STANDARD PURLIN BOX IS SUITABLE FOR ROOM THICKNESS OF 50-75mm N L SECTION B-B J TYP CRS K CRS PURLIN BOX SECURED TO PURLIN BOX SECURED TO J TYP CRSTRIMMERS WITH M10 TRIMMERS WITH M10 K LINDAPTERS CRS (NOT SUPPLIEDLINDAPTERS (NOT SUPPLIED BY ELTA FANS) BY ELTA FANS) SECURE UNIT TO HARDWOOD SILL WITH M10 COACH BOLTS (NOT SUPPLIED BY ELTA FANS) M K CRS A H TYP CRS A H TYP CRS A 50 G BETWEEN TRIMMERS A 50 G BETWEEN TRIMMERS B B PRODUCT CODE A B C D E F SSRV315/4-1AC SSRV350/4-1AC SSRV400/4/6-3AC SSRV400/4-1AC SSRV450/4/6-3AC SSRV450/4-1AC SSRV450/6-1AC SSRV500/4/6-3AC SSRV500/4-1AC SSRV500/6-1AC SSRV560/4-1AC SSRV560/4/6-3AC SSRV560/6-1AC SSRV630/4/6-3AC SSRV630/6/8-3AC SSRV630/6-1AC SSRV710/4/6-3AC SSRV710/6/8-3AC A B C D E F G H J K L M N Weight kg SSFV31/ SSFV40/ SSFV50/ SSFV63/ Dimensions are in mm. Accessories Purlin Box Soaker Sheet Drop in Silencer 600mm Long Drop in Silencer 900mm Long Drop in Silencer 1200mm Long SSFV-31/35 039B-PB31/ SP31/ SFDS-0600-A 068-SFDS-0900-A 068-SFDS-1200-A SSFV-40/45 039B-PB40/ SP40/ SFDS-0600-B 068-SFDS-0900-B 068-SFDS-1200-B SSFV-50/ SP50/ SP50/ SFDS-0600-C 068-SFDS-0900-C 068-SFDS-1200-C SSFV-63/71 039B-PB63/ SP63/ SFDS-0600-D 068-SFDS-0900-D 068-SFDS-1200-D Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 179

180 SKYFLOW SSFV Notes 180 Tel: Fax: Visit: eltaselect.com

181 High Temperature Tel: Fax: Visit: eltaselect.com 181

182 182 Tel: Fax: Visit: eltaselect.com

183 BIFLOW SB (CYL) Bifurcated Cylindrical Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 3 standard sizes from 400mm to 630mm. ü Air volume flow rates up to 4.50 m³/s. ü Static pressures up to 200 Pa. ü Suitable for operating temperatures up to +200 C. ü Available in AC. CASING IMPELLER QUALITY MANAGEMENT High Temperature The all metal fan casing provides a long lasting and robust construction. The units have been constructed from sheet steel with both motor and impeller mounted within the length of the unit casing. The motor is located out of the airstream in a single entry tunnel into the casing making the unit suitable for temperatures up to +200 C. All casing parts are heavy gauge mild steel sheet, roll formed and welded, then hot dip galvanised to BS EN ISO 1461:1999 after fabrication. Adjustable pitch aerofoil impellers are provided with blades made from high quality pressure die cast aluminium (LM6), natural finish. Impellers are factory set at an angle to provide maximum performance. The hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are to be dynamically balanced to ISO Grade G6.3. MOTORS Motors are to be foot mounted totally enclosed metric type to IP55, with sealed for life bearings, standard industrial paint finish and Class H insulation to EN Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SB (CYL) units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Kitchen Extract Spray Booths Hot Gas Situations Corrosive Atmospheres Boiler Houses Heavy Industrial ACCESSORIES For full accessories & controls information please visit eltaselect.com Ancillary Pack : APK Mounting Feet : 060B Matching Flanges : 061B Flexible Connections : 063 PU AV Mounts (Set of 4) : Damper : 019 Bell Mouth Inlet : 241B Silencer : 068 DE*P(C) Impeller Side Guard : 078C Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 183

184 BIFLOW SB (CYL) Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min Airflow Airflow Static Pressure Pa Motor Electrical Data Peak Amps SC Amps Output kw 3m SB400-CYL m³/s SB500-CYL m³/s SB630-CYL m³/s Dimensional Data E-HOLES F EQUISPACED ON G PCD AIRFLOW A B C A B C E F G Weight kg SB400-CYL SB500-CYL SB630-CYL Dimensions are in mm. Exempt from ErP of the European Parliament. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Data provided at standard air density of 1.2 kg/m³. Peak 400V / 3Ph / 50Hz. 184 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

185 BIFLOW SB (CYL) Accessories Impeller Side Guard Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) Damper SB400-CYL C-0400-C APK400SBCYL/ B B PU STD SB500-CYL C-0500-C APK500SBCYL/ B B PU STD SB630-CYL C-0630-C APK630SBCYL/ B B PU STD Bell Mouth Inlet Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded SB400-CYL B-0400-BELL DEP DENP DEP DENP SB500-CYL B-0500-BELL DEP DENP DEP DENP SB630-CYL B-0630-BELL DEP DENP DEP DENP * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 185

186 BIFLOW SB (CYL) Notes 186 Tel: Fax: Visit: eltaselect.com

187 BIFLOW SB (CON) Bifurcated Conical Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 4 standard sizes from 250mm to 500mm. ü Air volume flow rates up to 3.80 m³/s. ü Static pressures up to 600 Pa. ü Suitable for operating temperatures up to +200 C. ü Available in AC. CASING The all metal fan casing provides a long lasting and robust construction. The units have been constructed from sheet steel with both motor and impeller mounted within the length of the unit casing. The motor is located out of the airstream in a tunnel which traverses the casing making the unit suitable for temperatures up to +200 C. All casing parts are heavy gauge mild steel sheet, roll formed and welded, then hot dip galvanised to BS EN ISO 1461:1999 after fabrication. IMPELLER Adjustable pitch aerofoil impellers are provided with blades made from high quality pressure die cast aluminium (LM6), natural finish. Impellers are factory set at an angle to provide maximum performance. The hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are to be dynamically balanced to ISO Grade G6.3. MOTORS Motors are to be foot mounted totally enclosed metric type to IP55, with sealed for life bearings, standard industrial paint finish and Class H insulation to EN QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SB (CON) units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Kitchen Extract Spray Booths Hot Gas Situations Corrosive Atmospheres Boiler Houses Heavy Industrial ACCESSORIES For full accessories & controls information please visit eltaselect.com Ancillary Pack : APK Mounting Feet : 060B Matching Flanges : 061B Flexible Connections : 063 PU AV Mounts (Set of 4) : Damper : 019 Bell Mouth Inlet : 241B Silencer : 068 DE*P(C) Impeller Side Guard : 078C Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 187

188 BIFLOW SB (CON) Performance, SFP & Electrical Data SINGLE Phase to 240V / 50Hz Speed r/min Airflow SFP Airflow Static Pressure Pa Motor Electrical Data Peak Amps Input kw 3m SB250-CON m³/s Inlet 48 SB315-CON m³/s Inlet 51 THREE Phase to 415V / 50Hz Speed r/min Airflow SFP Airflow Static Pressure Pa Motor Electrical Data Peak Amps Input kw 3m SB250-CON m³/s Inlet 61 SB250-CON m³/s Inlet 48 SB315-CON m³/s Inlet 64 SB315-CON m³/s Inlet 51 SB400-CON m³/s Inlet 70 SB500-CON m³/s Inlet 80 Dimensional Data E-HOLES F EQUISPACED ON G PCD AIRFLOW A D B H OPTIONAL MOUNTING FEET c A B C D E F G H Weight kg SB SB SB315-CON SB SB Dimensions are in mm. 1Ph 3Ph Exempt from ErP of the European Parliament. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Data provided at standard air density of 1.2 kg/m³. 188 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

189 BIFLOW SB (CON) Accessories Impeller Side Guard Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) Damper SB250-CON C-0250-C APK250SBCON/ B-0250-B 061B-0250-B PU STD SB315-CON C-0315-C APK315SBCON/ B-0315-B 061B PU STD Bell Mouth Inlet Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded SB250-CON B DEP DENP DEP DENP SB315-CON B DEP DENP DEP DENP Impeller Side Guard Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) Damper SB250-CON C-0250-C APK250SBCON/ B-0250-B 061B-0250-B PU STD SB250-CON C-0250-C APK250SBCON/ B-0250-B 061B-0250-B PU STD SB315-CON C-0315-C APK315SBCON/ B-0315-B 061B PU STD SB315-CON C-0315-C APK315SBCON/ B-0315-B 061B PU STD SB400-CON C-0400-C APK400SBCON/ B-0400-B 061B PU STD SB500-CON C-0500-C APK500SBCON/ B-0500-B 061B PU STD Bell Mouth Inlet Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded SB250-CON B DEP DENP DEP SB250-CON B DEP DENP DEP SB315-CON B DEP DENP DEP SB315-CON B DEP DENP DEP SB400-CON B-0400-BELL DEP DENP DEP SB500-CON B-0500-BELL DEP DENP DEP * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 189

190 BIFLOW SB (CON) Notes 190 Tel: Fax: Visit: eltaselect.com

191 QUBE SQU-HT(S) Centrifugal Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 6 physical sizes with 8 models from 315mm to 710mm. ü Air volume flow rates up to 3.9 m³/s. ü Static pressures up to 1120 Pa. ü Suitable for operating temperatures up to +120 C ( In-duct). ü Inverter speed controllable via 1Ph and 3Ph supply. ü Interchangeable double skinned panels. ü Available in AC. CASING Constructed from self supporting corrosion-resistant extruded Aluminium section, assembled with aluminium corners and 25mm thick double skinned removable panels, manufactured from pre-galvanised steel, in-filled with a non flammable mineral wool, 60kg/m³, thereby minimising breakout noise. IMPELLER A high efficiency backward curved welded steel impeller with a nonoverloading power characteristic, suitable for continuous S1 operation up to +120 C, finished with a powder coating to RAL 5002 for greater surface protection, and dynamically balanced to G2.5 / G6.3 according to ISO1940 part 1. MOTORS Three phase multi-voltage IP55 TEFC Foot / Flange mounted IEC frame motors, wound for either (Delta) 230V/3Ph/50Hz or (Star) at 400V/3Ph/50Hz connection, suitable for speed control when used with the Eltadrive VSD range of frequency inverter controls. Electrical connection is made directly to the IP55 motor terminal box. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SQU-HT units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Kitchens Restaurants Schools Colleges Shops Shower Rooms Factories ACCESSORIES For full accessories & controls information please visit eltaselect.com Inverter : 149-ODE Matching Flanges : 061B Flexible Connections : 063 PU Silencer : 068 DE*P(C) Weather Hood : 064 WHV Transition Piece : 260 TP Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 191

192 QUBE SQU-HT(S) Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min SQU1/4-3HT(s) 1441 SQU2/4-3HT(s) 1445 SQU22/4-3HT(s) 1470 SQU3/4-3HT(s) 1471 SQU23/4-3HT(s) 1445 SQU24/4-3HT(s) 1435 SQU4/4-3HT(s) 1447 SQU4/6-3HT (s) 910 Airflow SFP Airflow Static Pressure Pa. Overall Efficiency Motor % kw Peak m³/s Amps Electrical Data FLC* Amps FLC# Amps m Inlet 51 Outlet 53 W/(L/s) Breakout 38 m³/s Inlet 57 Outlet 59 W/(L/s) Breakout 44 m³/s Inlet 60 Outlet 62 W/(L/s) Breakout 47 m³/s Inlet 60 Outlet 62 W/(L/s) Breakout 47 m³/s Inlet 66 Outlet 68 W/(L/s) Breakout 53 m³/s Inlet 66 Outlet 68 W/(L/s) Breakout 53 m³/s Inlet 66 Outlet 68 W/(L/s) Breakout 48 m³/s Inlet 59 Outlet 61 W/(L/s) Breakout 46 The unit is supplied as either an end inlet vertical discharge unit (SQU-HT) or as a side inlet vertical discharge unit (SQU-HTS). Exempt from ErP of the European Parliament. FLC* Amps at 230V / 1Ph / 50Hz input before a 1Ph to 3Ph Variable Speed Drive. FLC# Amps at 400V / 3Ph / 50Hz input before a 3Ph to 3Ph Variable Speed Drive. A variable speed drive (Eltadrive) must be installed with this fan. Data shown is for end inlet configuration. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. 192 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

193 QUBE SQU-HT(S) Dimensional Data OUTLET D A OUTLET B 50mm TYP A C Spigot END INLET OPTION A SIDE INLET OPTION SIDE INLET OPTION End Inlet Spigot Ø A B C D Side Inlet W x H Outlet W x H Weight kg SQU1/4HT x x SQU2/4HT x x SQU22/4HT x x SQU3/4HT x x SQU23/4HT x x SQU24/4HT x x SQU4/4HT x x SQU4/6HT x x Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 193

194 QUBE SQU-HT(S) Accessories Inverter Controller 1PH-3PH IP66 Inverter Controller 1PH-3PH IP20 Inverter Controller 3PH-3PH IP66 Inverter Controller 3PH-3PH IP20 Matching Flanges (each) Flexible Connections (each) SQU1/4-3HT* 149-ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 061B PU250 SQU2/4-3HT* 149-ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 061B PU250 SQU22/4-3HT* 149-ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 061B PU250 SQU3/4-3HT* 149-ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA12 061B PU250 SQU23/4-3HT* ODE KA4Y 149-ODE KA42 061B PU250 SQU24/4-3HT* ODE KA4Y 149-ODE KA42 061B PU250 SQU4/4-3HT* ODE KA4Y 149-ODE KA42 061B PU250 SQU4/6-3HT* 149-ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA42 061B PU250 Inlet Transition piece Outlet Transistion Piece Weather Hood Silencer 1D Unpodded Silencer 2D Unpodded Wiring Diagram SQU1/4-3HT* 260-SQU-TPI-A 260-SQU-TPO-A 064-SQU-WHV-A DENP DENP SQU2/4-3HT* 260-SQU-TPI-B 260-SQU-TPO-B 064-SQU-WHV-B DENP DENP SQU22/4-3HT* 260-SQU-TPI-C 260-SQU-TPO-C 064-SQU-WHV-B DENP DENP SQU3/4-3HT* 260-SQU-TPI-D 260-SQU-TPO-D 064-SQU-WHV-C DENP DENP SQU23/4-3HT* 260-SQU-TPI-E 260-SQU-TPO-E 064-SQU-WHV-C DENP DENP SQU24/4-3HT* 260-SQU-TPI-F 260-SQU-TPO-F 064-SQU-WHV-D DENP DENP SQU4/4-3HT* 260-SQU-TPI-G 260-SQU-TPO-G 064-SQU-WHV-D DENP DENP SQU4/6-3HT* 260-SQU-TPI-G 260-SQU-TPO-G 064-SQU-WHV-D DENP DENP * Add S to code for side entry. HTS model only. For horizontal discharge only. Fan & inverter packages available. Please contact Elta Fans for more information. 194 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

195 QUBE SQU-HT(S) Notes Tel: Fax: Visit: eltaselect.com 195

196 SLIM QUBE SSQU-HT Centrifugal Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 4 standard sizes, 9 models. ü Air volume flow rates up to m³/s. ü Static pressures up to 1390 Pa. ü Suitable for operating temperatures up to +120 C (In duct). ü Inverter speed controllable via 1Ph and 3Ph supply. ü Available in AC. CASING Constructed from self supporting corrosion-resistant extruded Aluminium section, assembled with aluminium corners and 25mm thick double skinned removable panels, manufactured from pre-galvanised steel, in-filled with a non flammable mineral wool, 60kg/m³, thereby minimising breakout noise. IMPELLER A high efficiency backward curved welded steel impeller with a nonoverloading power characteristic, finished with a powder coating to RAL 5002 for greater surface protection, and dynamically balanced to G2.5 / G6.3 according to ISO1940 part 1. MOTORS Three phase multi-voltage IP55 TEFC Foot / Flange mounted IEC frame motors, wound for either (Delta) 230V/3Ph/50Hz or (Star) at 400V/3Ph/50Hz connection, suitable for speed control when used with the Eltadrive VSD range of frequency inverter controls. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001: All QUBe units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Kitchens Restaurants Schools Colleges Shops Shower Rooms Factories ACCESSORIES For full accessories & controls information please visit eltaselect.com Inverter : 149-ODE Flexible Connections : 063 PU Silencer : 068 DE*P(C) Weather Hood : 064 WHC Weather Hood : 064 WHV Transition Piece : 260 TP External Roof : 039 ER 196 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

197 SLIM QUBE SSQU-HT Performance, SFP & Electrical Data THREE Phase - 380V to 415V / 50Hz Speed r/min SSQU1/4-3HT 1431 SSQU2/4-3HT 1435 SSQU22/4-3HT 1470 SSQU3/4-3HT 1463 SSQU23/4-3HT 1440 SSQU4/4-3HT 1437 SSQU24/4-3BHT 1475 SSQU4/4-3BHT 1441 SSQU4/6-3HT 950 Airflow SFP Airflow Static Pressure Pa. Overall Efficiency % kw Motor Peak Amps Electrical Data FLC* Amps FLC# Amps 3m m³/s Inlet W/(L/s) Outlet 45 m³/s Inlet W/(L/s) Outlet 52 m³/s Inlet W/(L/s) Outlet 62 m³/s Inlet W/(L/s) Outlet 56 m³/s Inlet W/(L/s) Outlet 68 m³/s Inlet W/(L/s) Outlet 65 m³/s Inlet W/(L/s) Outlet 72 m³/s Inlet W/(L/s) Outlet 71 m³/s Inlet W/(L/s) Outlet 59 FLC* Amps at 230V / 1Ph / 50Hz input before a 1Ph to 3Ph Variable Speed Drive. FLC# Amps at 400V / 3Ph / 50Hz input before a 3Ph to 3Ph Variable Speed Drive. Exempt from ErP of the European Parliament. A variable speed drive (Eltadrive) must be installed with this fan. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 197

198 SLIM QUBE SSQU-HT Dimensional Data B C OUTLET W E Spigot D OUTLET H A A B C D E Inlet Spigot Outlet (W x H) Weight kg SSQU1/4-3HT x SSQU2/4-3HT x SSQU22/4-3HT x SSQU3/4-3HT x SSQU23/4-3HT x SSQU4/4-3BHT x SSQU24/4-3BHT x SSQU4/4-3HT x SSQU4/6-3HT x Dimensions are in mm. 198 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

199 SLIM QUBE SSQU-HT Accessories Inverter Controller 1PH-3PH IP66 Inverter Controller 1PH-3PH IP20 Inverter Controller 3PH-3PH IP66 Inverter Controller 3PH-3PH IP20 Flexible Connections (each) Circular Silencer 1D Unpodded Circular Silencer 2D Unpodded SSQU1/4-3HT 149-ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA PU DENP DENP SSQU2/4-3HT 149-ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA PU DENP DENP SSQU22/4-3HT 149-ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA PU DENP DENP SSQU3/4-3HT 149-ODE KB1Y 149-ODE KB ODE KA1Y 149-ODE KA PU DENP DENP SSQU23/4-3HT ODE KA4Y 149-ODE KA PU DENP DENP SSQU4/4-3HT ODE KA4Y 149-ODE KA PU DENP DENP SSQU24/4-3BHT ODE KA4Y 149-ODE KA PU DENP DENP SSQU4/4-3BHT ODE KA4Y 149-ODE KA PU DENP DENP SSQU4/6-3HT 149-ODE KB4Y 149-ODE KB ODE KA4Y 149-ODE KA PU DENP DENP Outlet Transition Piece External Roof Weather Hood (Vertical discharge only) Weather Hood (Horizontal discharge only) Wiring Diagram SSQU1/4-3HT 260-SSQU-TPO-A 039-SSQU-ER-A 064-SSQU-WHV-A 064-SSQU-WH-A SSQU2/4-3HT 260-SSQU-TPO-B 039-SSQU-ER-B 064-SSQU-WHV-B 064-SSQU-WH-B SSQU22/4-3HT 260-SSQU-TPO-C 039-SSQU-ER-C 064-SSQU-WHV-C 064-SSQU-WH-C SSQU3/4-3HT 260-SSQU-TPO-D 039-SSQU-ER-C 064-SSQU-WHV-D 064-SSQU-WH-D SSQU23/4-3HT 260-SSQU-TPO-E 039-SSQU-ER-D 064-SSQU-WHV-E 064-SSQU-WH-E SSQU4/4-3HT 260-SSQU-TPO-F 039-SSQU-ER-D 064-SSQU-WHV-F 064-SSQU-WH-F SSQU24/4-3BHT 260-SSQU-TPO-G 039-SSQU-ER-E 064-SSQU-WHV-G 064-SSQU-WH-G SSQU4/4-3BHT 260-SSQU-TPO-G 039-SSQU-ER-E 064-SSQU-WHV-G 064-SSQU-WH-G SSQU4/6-3HT 260-SSQU-TPO-G 039-SSQU-ER-D 064-SSQU-WHV-G 064-SSQU-WH-G Fan & inverter packages available. Please contact Elta Fans for more information. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 199

200 SLIM QUBE SSQU-HT Notes 200 Tel: Fax: Visit: eltaselect.com

201 Hazardous Area Tel: Fax: Visit: eltaselect.com 201

202 202 Tel: Fax: Visit: eltaselect.com

203 REVOLUTION SLCX ATEX Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 7 standard sizes from 355mm to 710mm. ü Air volume flow rates up to 6.8 m³/s. ü Static pressure up to 800 Pa. ü Suitable for operating temperatures up to +40 C. ü Suitable for extract or supply systems. ü Available in AC. CASING The all metal fan casing and guard provide a long lasting and robust construction. The units have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing. All casing parts are heavy gauge mild steel sheet, roll formed and welded, then hot dip galvanised to BS EN ISO 1461:1999 after fabrication. IMPELLER Adjustable pitch aerofoil impellers are provided with blades made from high quality carbon filled anti static material. Impellers are factory set at an angle to provide maximum performance. Hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are dynamically balanced to ISO Grade G6.3. MOTORS Motors according to Gas Zone, Ignition Temperature and Protection to Ex II 2G c IIC T4 X. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All ATEX units are to be tested to ISO 5801:1997 (airside performance) and BS 848 Part 2: 1985 (sound performance). TYPICAL APPLICATIONS Chemical Process Water and Sewage Treatment Material and Gas Waste Dust and Paint Extraction Battery Room Ventilation and Refrigeration ACCESSORIES For full accessories & controls information please visit eltaselect.com Ancillary Pack : APK Mounting Feet : 060B Matching Flanges : 061B Flexible Connections : 063 MAN AV Mounts (Set of 4) : Bell Mouth Inlet : 241B Silencer : 068 DE*P(C) Impeller Side Guard : 078C Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 203

204 REVOLUTION SLCX Performance, SFP & Electrical Data AC THREE Phase - 380V to 415V / 50Hz Speed r/min Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data FLC Amps SC Amps Output kw 3m SLCX355/ SLCX400/ SLCX400/ SLCX450/4-3B 1390 SLCX450/2-3A 2820 SLCX500/ SLCX500/ SLCX500/2-3B 2900 SLCX560/ SLCX630/ SLCX710/ m³/s Inlet W/(L/s) Outlet 49 m³/s Inlet W/(L/s) Outlet 53 m³/s Inlet W/(L/s) Outlet 61 m³/s Inlet W/(L/s) Outlet 56 m³/s Inlet W/(L/s) Outlet 68 m³/s Inlet W/(L/s) Outlet 59 m³/s Inlet W/(L/s) Outlet 73 m³/s Inlet W/(L/s) Outlet 80 m³/s Inlet W/(L/s) Outlet 62 m³/s Inlet W/(L/s) Outlet 65 m³/s Inlet W/(L/s) Outlet 71 Exempt from ErP of the European Parliament. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Data provided at standard air density of 1.2 kg/m³. Peak 400V / 3Ph / 50Hz. 204 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

205 REVOLUTION SLCX Dimensional Data AC E HOLES ØF EQUI-SPACED ON G PCD TERMINAL BOX WITH CUSTOMER ENTRY ØK D AIR-FLOW M6 EARTH STUD ØA C ØB A B C D E F G K Weight kg SLCX355/ M20 29 SLCX400/ M20 43 SLCX400/ M20 35 SLCX450/2-3A M20 47 SLCX450/4-3B M20 40 SLCX500/ M20 51 SLCX500/2-3B M20 68 SLCX500/ M20 47 SLCX560/ M20 63 SLCX630/ M20 64 SLCX710/ M20 70 Dimensions are in mm. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 205

206 REVOLUTION SLCX Accessories Impeller Side Guard Ancillary Pack* Mounting Feet (each) Matching Flanges (each) Flexible Connections (each) AV Mounts (set of 4) Bell Mouth Inlet SLCX355/ C-0350-C APKX350/ B B BM B-0350-BELL SLCX400/ C-0400-C APKX400/ B B BM B-0400-BELL SLCX400/ C-0400-C APKX400/ B B BM B-0400-BELL SLCX450/2-3A 078C-0450-C APKX450/ B B BM B-0450-BELL SLCX450/4-3B 078C-0450-C APKX450/ B B BM B-0450-BELL SLCX500/ C-0500-C APKX500/ B B BM B-0500-BELL SLCX500/2-3B 078C-0500-C APKX500/ B B BM B-0500-BELL SLCX500/ C-0500-C APKX500/ B B BM B-0500-BELL SLCX560/ C-0560-C APKX560/ B B BM B-0560-BELL SLCX630/ C-0630-C APKX630/ B B BM B-0630-BELL SLCX710/ C-0710-C APKX710/ B B BM B-0710-BELL Silencer 1D Podded Silencer 1D Unpodded Silencer 2D Podded Silencer 2D Unpodded Wiring DIagram SLCX355/ DEP DENP DEP DENP SLCX400/ DEP DENP DEP DENP SLCX400/ DEP DENP DEP DENP SLCX450/2-3A DEP DENP DEP DENP SLCX450/4-3B DEP DENP DEP DENP SLCX500/ DEP DENP DEP DENP SLCX500/2-3B DEP DENP DEP DENP SLCX500/ DEP DENP DEP DENP SLCX560/ DEP DENP DEP DENP SLCX630/ DEP DENP DEP DENP SLCX710/ DEP DENP DEP DENP * Consists of Flexible Connections, Matching Flanges, AV Mounts and Mounting Feet. 206 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

207 REVOLUTION SLCX Notes Tel: Fax: Visit: eltaselect.com 207

208 RAPTOR SFB ATEX Plate Mounted Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 4 standard sizes from 350mm to 650mm. ü Air volume flow rates up to 2.57 m³/s. ü Static pressure up to 125 Pa. ü Suitable for operating temperatures up to +40 C. ü Available in AC. Suitable for extract or supply systems. CASING The all metal fan casing and guard provides a long lasting and robust construction. The units have been constructed from mild steel and suitably treated to ensure full corrosion protection, the guard shall be powder coated polyester epoxy paint finish in black (RAL 9005). Fan plates shall have a surface coated to fulfil the requirements in DIN EN regarding electrostatic charges with paint finish in black (RAL 9005). IMPELLER Pressed aluminium impellers providing low noise and increased efficiency with protective measures between rotating and stationary components, dynamically balanced to ISO Grade G6.3, and finished in black (RAL 9005). MOTORS Motors are Ziehl-Abegg, highly efficient, lightweight external rotor motors with sealed for life, maintenance free ball bearings; which allows the fan to be installed at any angle. Motors are all suitable for speed control and each motor has temperature monitoring by integrated PTC Thermistor. Motors according to: Gas, Zone and ignition temperature. Protection to Ex II 2G c Ex e IIB T4 classified for constructional safety and fulfil the requirements stated in 94/4/EU (ATEX) directive. Fans are suitable for operating temperatures between -20 C and +40 C. Electrical connection to the motor is via a 650mm long flying lead. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SFB units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Chemical Process Water and Sewage Treatment Material and Gas Waste Dust and Paint Extraction Battery Room Ventilation and Refrigeration ACCESSORIES For full accessories & controls information please visit eltaselect.com Transformer Controller* : 149-TC Thermistor Protection Relay : 149-U-EK IP54 Option also available * Controller is not ATEX rated and must be mounted outside the hazardous area 208 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

209 RAPTOR SFB Performance, SFP & Electrical Data AC THREE Phase - 380V to 415V / 50Hz Speed r/min SFB035-VDE.4Y.A4P 1428 SFB042-VDE.4Y.A4P 1402 SFB056-SDE.4Y.A4P 914 SFB065-SDE.4Y.A4P 894 Airflow SFP Airflow Static Pressure Pa Overall Efficiency % Motor Electrical Data FLC Amps SC Amps Input kw 3m m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - m³/s Inlet W/(L/s) Outlet - Exempt from ErP of the European Parliament. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Data provided at standard air density of 1.2 kg/m³. Peak 400V / 3Ph / 50Hz. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 209

210 RAPTOR SFB Dimensional Data D E C FLYING LEAD A B 4 HOLES J DIA H F G A B C D E F G H J Weight kg SFB035-VDE.4Y.A4P SFB042-VDE.4Y.A4P SFB056-SDE.4Y.A4P SFB065-SDE.4Y.A4P Dimensions are in mm. 210 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

211 RAPTOR SFB Accessories Transformer Controller* Thermistor Protection Relay IP54 Protection Relay Enclosure SFB035-VDE.4Y.A4P 149-TC U-EK230E 149-U-EK230E-HOUSING SFB042-VDE.4Y.A4P 149-TC U-EK230E 149-U-EK230E-HOUSING SFB056-SDE.4Y.A4P 149-TC U-EK230E 149-U-EK230E-HOUSING SFB065-SDE.4Y.A4P 149-TC U-EK230E 149-U-EK230E-HOUSING * Controller is not ATEX rated and must be mounted outside the hazardous area. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 211

212 RAPTOR SFB Notes 212 Tel: Fax: Visit: eltaselect.com

213 Destratification Tel: Fax: Visit: eltaselect.com 213

214 214 Tel: Fax: Visit: eltaselect.com

215 ZOO FAN SDF Destratification and Spot Cooling During the heating season, rising heat results in thermal stratification that can make the area near the ceiling quite warm. As a result, the entire space must be overheated in order to maintain comfortable temperatures at floor level: See figure 1. Overheating results in significantly more energy consumption than necessary and usually creates hot and cold spots in a building. A ZOO Fan creates a gentle, concise column of air that brings warm air down to floor level, destratifies the space and reduces the temperature differential to as low as 1 overall: See figures 2 and 3. Figure 1: The above thermal image is from a CFD (Computational Fluid Dynamics) computer model of a 12.2m² space with a 7.6m flat ceiling deck and a ceiling-mounted heat source with a thermostat affixed 1.5m above the floor, set at 21 C Figure 2: This shows what happens almost immediately to this built-up heat when a ZOO Fan (represented by the white silhouette) is turned on in this CFD Analysis. Figure 3: Destratification results in an even temperature throughout the Zone Of Occupancy. Creature comfort improves noticeably and energy consumption is reduced, often significantly. Zone Of Occupancy Thermal stratification causes similar problems during the cooling season. Destratification of the occupied zone gives a uniform temperature throughout so no area needs to be over-cooled in order to maintain an acceptable temperature in other elsewhere. The concentrated columns of air produced by ZOO Fans eliminate the need for physical duct work, gently forcing the cool, conditioned air down to the Zone Of Occupancy. The HVAC systems cycle less, the air handlers run less, introduction of outside air is reduced and the air keeps moving. ZOO Fans, hung in closer proximity, can also be used as spot coolers. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 215

216 ZOO FAN SDF Destratification Ceiling Mounted Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 2 standard sizes from 250mm to 300mm. ü Air volume flow rates up to 0.593m³/s (AC) and 0.656m³/s (EC). ü High quality Ziehl-Abegg FE2owlet. ü Suitable for operating temperatures up to +70 C. ü Fully speed controllable. ü Available in AC & EC. CASING The Fire-Resistant (5VB), UV-treated PC ABS plastic housing provides a long lasting and robust construction. IMPELLER Impellers are high quality Ziehl- Abegg FE2owlet in high performance composite material providing enhanced aerodynamic properties and reliability, dynamically balanced to ISO Grade G6.3, and finished in black (RAL 9005). MOTORS Motors are highly efficient AC or EC, lightweight external rotor motors suitable for speed control. Each motor has integral overload protection. Fans are supplied with a fitted IP54 terminal box, which allows the fan to be positioned conveniently to incoming electrical inputs. QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SDF units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Factories Sports Halls Shops Industrial units Warehousing ACCESSORIES For full accessories & controls information please visit eltaselect.com Transformer Controller : 149-TC Electronic Controller :149-POT 216 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

217 ZOO FAN SDF Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz or 60Hz SDF250/4-1AC SDF300/4-1AC Frequency (Hz) FLC Amps Motor Electrical Data SC Amps Input kw r/min Max Volume m³/s Max Operating Temp C Inlet 37 Outlet 38 Inlet 41 Outlet 41 Inlet 43 Outlet 42 Inlet 46 Outlet 46 SINGLE Phase - 200V to 277V / 50Hz or 60Hz Motor Electrical Data FLC Amos Input kw r/min Max Volume m³/s Max Operating Temp C SDF250/4-1EC SDF300/4-1EC Inlet 53 Outlet 53 Inlet 51 Outlet 49 Exempt from ErP of the European Parliament. Fan data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Data provided at standard air density of 1.2 kg/m³. Peak 400V / 3Ph / 50Hz. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 217

218 ZOO FAN SDF Dimensional Data A F E B C D A B C D E F Weight kg SDF SDF Dimensions are in mm. Accessories Transformer Controller Electronic Controller Wiring Diagram SDF250/4-1AC 149-TC POT SDF300/4-1AC 149-TC POT POT-10 required if 149-TC is to be used in manual control. Electronic Controller Wiring Diagram SDF250/4-1EC 149-POT SDF300/4-1EC 149-POT Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

219 ZOO FAN SDF Selecting a Zoo Fan The calculations for destratification are worked out using the volume of air within the area, rather than the floor area. 1. Calculate volume in metres by multiplying the length, width and average height: Length x Width x Average Height = Volume in m³ EXAMPLE 1. A big box store with a length of 75m, 50m width and a height of 7m has the following volume: 75 x 50 x 7 = Volume 26,250m³ 2. Next, determine which fan to use based on ceiling height. ZOO Fans are currently manufactured in two sizes: SDF250 AC: 0.265m³/s, EC: 0.423m³/s. Applications up to 9m height. SDF300 AC: 0.532m³/s, EC: 0.656m³/s. Applications up to 20m height. 2. As the celing height is less than 9m the SDF250 AC can be used: SDF250 AC 0.265m³/s. Applications up to 9m height. 3. After selecting the fan size you are going to use (SDF250 or SDF300), use the following formula: Volume m³ 3600 m³/s = number of fans to install Volume of the space in m³ 3600 (seconds in an hour) m³/s (of the fan selected) = the number of fans that are required to achieve one (1) air turn in one (1) hour. Every ZOO Fan is variable-speed controllable and can be angled easily, if need be, to direct the flow. This allows for ease of installation and control across a broad range of applications. By simply adjusting the speed of the fan, the two sizes and models shown above can effectively cover ceiling heights from 3m to 20m. In most cases it is best to use the SDF250 for ceiling heights up to 9m and the SDF300 for anything higher than 9m (see Other Considerations for additional information). 3. Using the formula and rounding the number up, it shows 28 AC SDF250 fans would be required: 26, = Other Considerations: There are some instances where you may consider the 300mm unit for lower ceiling heights. For example, with a ceiling height of 8m in a warehouse that is not constantly occupied, or where racking system and overhead truck doors are evident, you would select the 300mm or EC model to have the option of delivering a higher volume of air at floor level. You would also select the 300mm model for applications where you want to use the fans for spot cooling. In a more constantly occupied space where your ceiling height is 9m or less, and higher air speeds might cause discomfort for the occupants, it s preferable to use the SDF200. Examples would be a grocery store or a car showroom. This would create less draught and still destratify the space effectively. Height 7m Width Length 50m 75m Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 219

220 ZOO FAN SDF Notes 220 Tel: Fax: Visit: eltaselect.com

221 Portable Cooling Tel: Fax: Visit: eltaselect.com 221

222 222 Tel: Fax: Visit: eltaselect.com

223 RAPTOR COOLER SRC Circulating Axial Flow Portable Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü Available in 450mm only. ü Air volume flow rates up to 1.82 m³/s. ü Free standing. ü Suitable for operating temperatures up to +60 C. ü Variable fan position. ü Available in AC. CASING The all metal fan casing and guard provide a long lasting and robust construction. The units have been constructed from mild steel and suitably treated to ensure full corrosion protection. Fan casings are powder coated polyester epoxy paint finish in pastel beige (RAL 7032). The fan inlet and discharge shall be suitably protected by bright zinc plated steel wire guards. The unit shall be supplied complete with integral IP51 speed controller and flying lead fitted with 13A UK plug. IMPELLER Ziehl-Abegg FE2owlet impellers are provided with blades made from high quality pressure die cast aluminium or high performance composite material providing enhanced aerodynamic properties and increased efficiency, dynamically balanced to ISO Grade G6.3 and finished in black (RAL 9005). MOTORS Motors are highly efficient, lightweight external rotor motors, insulated to Class F, with integral thermal overload protection. Weatherproofed to IP54, QUALITY MANAGEMENT Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All PC units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance). TYPICAL APPLICATIONS Temporary Ventilation Construction Sites Machine Shops Welding Bays Foundries Marquees Workshops Gymnasiums Large Offices Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 223

224 RAPTOR COOLER SRC Performance, SFP & Electrical Data AC SINGLE Phase - 220V to 240V / 50Hz Speed r/min SRC450/4-1AC 1302 Airflow SFP Max Volume Overall Efficiency % FMEG N Motor Electrical Data Peak Amps SC Amps Input kw 3m m³/s Inlet W/(L/s) 0.28 Outlet 49 Exempt from ErP of the European Parliament. Fan data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Data provided at standard air density of 1.2 kg/m³. Peak 400V / 3Ph / 50Hz. Dimensional Data A D B C A B C D Weight kg SRCC450/ Dimensions are in mm. 224 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

225 RAPTOR COOLER SRC Notes Tel: Fax: Visit: eltaselect.com 225

226 RAPTOR COOLER SRC Notes 226 Tel: Fax: Visit: eltaselect.com

227 Additional s Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 227

228 DCV CONTROLS A selection of our fans are available with DCV controls The Principle Behind DCV Demand Control Ventilation or DCV, is a technological innovation that provides an effective, efficient means of using variable speed ventilation solutions to meet variable occupancy levels in spaces requiring ventilation. 149-DCV-CO2 149-DCV-DPT DCV-H1 149-DCV-HRT 149-DCV-PIR 149-DCV-TRT DCV Controls CO2 Transmitter Pressure Transmitter Room Humidistat Humidity Transmitter Presence Detector Temperature Transmitter Demand Control Ventilation allows the user to control the whole ventilation system, including all fans and components, to provide variable degrees of ventilation for changing occupancy levels. This is achieved by using different sensors to supply an array of different detection modules which identify the level of spatial contaminant within the building (e.g. people, temperature, CO₂, humidity etc). These sensors provide an almost infinite amount of possible variation to the ventilation system provided so that it matches almost identically, the level of occupation within the area to be ventilated. Zone Controller At the heart of the Elta Fans DCV system is the zone controller - designed to monitor and control one or more fan units simultaneously, with 6 preprogrammed fan applications. Each application has its own factory set parameters (input value range, set-points, P-band, min and max speeds) and control function. All of which can be changed in the field via the display unit, which is connected via a SELV cable and incorporates a digital display. Control Functions Remote enable (BMS) Trickle and boost Heater battery operation Fan run status (fan fail) Control input signal Time/clock Manual speed control Master/slave fan operation Twin fan operation (c/w duty share change over) Min/max speed settings for master or slave fan Sensors The DCV systems various sensors provide continuous real time feedback monitoring of the ambient air conditions through temperature, humidity, CO₂ or pressure in the occupied space. 228 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

229 DCV CONTROLS A selection of our fans are available with DCV controls Typical Classroom Environment Pick up ducting for fan DCV Zone Controller (integral to fan) Quietflow DCV Box Fan Ceiling Grille (Inlet) Ceiling Room Controller Sensor Exhausted air to outside ROOM CONTROLLER SENSORS PRESSURE SENSOR PASSIVE INFRARED DETECTOR SLAVE FAN - CO₂ - Humidity - Temperature For constant pressure For occupancy detection Operate a second fan from a single room controller Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 229

230 ARCO RANGE Axial Extract Fans residential OVERVIEW The ARCO range of intermittent extract fans are ideal for extracting stale air when required. They are suitable for wall, ceiling and window mounting. The Arco range of fans have been developed to provide energy efficient and silent ventilation. The Arco fans are available in 3 different cover options that all offer discrete styling. For full detailed information please visit homevent.co.uk. QUICK FACTS ü Available in 3 sizes to suit bathroom, utility and kitchen. ü 3 different styles; standard, automatic grille and design front facia. ü IPX4 to allow installation in Zones 1+2. ü Timer version available to allow run on after the trigger has been removed. ü Humidistat version to trigger the fan when there is excess humidity. AVIO In-Line Axial Fan residential OVERVIEW The AVIO range of intermittent extract fans are suitable for mounting in short duct lengths, allowing them to be used with more aesthetic grilles and the fan is hidden away. It is the perfect choice for extracting humid and stale air. The Avio range of fans have been developed to provide energy efficient and silent ventilation. For full detailed information please visit homevent.co.uk. QUICK FACTS ü Available in 3 sizes to suit bathroom, utility and kitchen. ü IPX4 to allow installation in Zones 1+2. ü Timer version available to allow run on after the trigger has been removed. ü Low Power consumption from under 8W. ü Aerodynamic impeller providing enhanced performance and sound. 230 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

231 CETO Axial Extract Fan residential OVERVIEW The CETO 100 is a centrifugal intermittent extract fan for extracting stale air from bathrooms. The fan develops high pressures allowing it to be used with longer duct runs where there is no external wall. Can be installed on wall or ceiling. For full detailed information please visit homevent.co.uk. QUICK FACTS ü IPX4 to allow installation in Zones 1+2. ü Integral back-draught shutter to prevent draughts entering the room when the fan is off. ü Improved performance thanks to the unique air straightener to optimise performance and reduce power consumption. ü Aesthetic front cover with discrete yet modern styling that goes well with a range of interior finishes. MORI MEV Centralised Mechanical Extract Ventilation Unit residential OVERVIEW A range of centralised continuously running, low energy, ultra-quiet extract fans that extract from multiple rooms such as kitchens, utility rooms, bathrooms, and toilets via a system of ductwork with a single discharge to atmosphere. For full detailed information please visit homevent.co.uk. QUICK FACTS üextremely low power consumption. Annual running costs as little as 5 per year for continuous operation. ü Ultra-Quiet. Almost imperceptible noise on background settings. ü Flexible installation. 4 inlet spigots to aid in installation and can simultaneously extract from multiple wet rooms to minimise system pressure drops. ü Very adaptable. Numerous control strategies to choose from and a wide duty range. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 231

232 MORI dmev Decentralised Mechanical Extract Ventilation residential OVERVIEW The MORI dmev range of fans, are continuously running mechanical extract fans which are suitable for installation in all wetrooms including kitchen, utility, bathroom and W.C. The range is class leading in terms of energy usage and noise. Continuously running fans use much less energy and have lower noise levels compared to intermittent fans and are often the best way to prevent the build-up of humidity. For full detailed information please visit homevent.co.uk. QUICK FACTS ü Extremely low power consumption. Annual running costs of less than 1 per year. ü Ultra-Quiet. Almost imperceptible noise on background settings. ü Aesthetically pleasing front cover. Discrete yet stylish, blends in well with different wall and ceiling finishes. ü Versatile. Suitable for wall, ceiling or window mounting in W.C., bathroom, kitchen and utility rooms. PIV LOFT Loft Mounted Positive Input Ventilation Unit residential OVERVIEW The PIV LOFT is a loft mounted ultra-quiet, low energy, low maintenance, home ventilation unit. The unit is designed to help ventilate a home using the well-established Positive Input Ventilation (PIV) principle. PIV units prevent and cure condensation and dampness related problems in homes. They are also used to control other indoor air pollutants and can be an effective means for controlling Radon gas in some properties. For full detailed information please visit homevent.co.uk. QUICK FACTS ü Small discrete, white plastic supply air diffuser which will blend well with any ceiling while distributing the air as required. ü Low energy ultra-low quiet fan/motor assembly. ü Robust, lightweight fan casing constructing. ü Large very long life, grade G4 filter. ü Integral, multi-functional controls to suit the individual requirements of a home and its occupants. 232 Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

233 MORI HR Alternate, Supply & Extract Fan With Heat Retention residential OVERVIEW A range of continuously running, low energy ultra-quiet alternate flow supply and extract fans with heat retention facility for use in habitable rooms such as living rooms, bedrooms, dining rooms basements and hallways. The unit essentially helps a room breathe and reduces indoor air pollutants and humidity levels. It is an ideal unit for tackling problems associated with condensation dampness such as mould growth. For full detailed information please visit homevent.co.uk. QUICK FACTS ü Saves Energy Regenerative Heat Exchanger Recovers up to 90% of the heat that would otherwise be lost. ü Extremely Low Power Consumption, costs less than 2 a year to run and can save around 50 of heating bills. ü Very quiet running. ü Aesthetic Front Fascia The fascia is modern and discrete with a low profile to blend into any home. Easily removed for cleaning. VIGO RANGE Continuous Mechanical Ventilation With Heat Recovery residential OVERVIEW The VIGO range covers various models that provide supply and extract ventilation whilst recovering heat from the extract air that would otherwise be lost. There is a Vigo to suit any need from small flats and houses right up to large dwellings. All benefitting from the high level of development. For full detailed information please visit homevent.co.uk. QUICK FACTS ü Low Noise Internally the unit is aerodynamically designed to ensure noise levels are extremely low. ü Efficient Heat Recovery Up to 92% of the heat from the stale air is recovered via a highly efficient counter-flow heat exchanger. ü Energy efficient motors providing low running costs. ü Available with an automatic LCD Display with advanced control features. ü Horizontal and vertical models available. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 233

234 KOMFOVENT DOMEKT RVU Heat Recovery Unit heat recovery OVERVIEW The Komfovent DOMEKT Heat Recovery Units are designed to create healthy indoor air quality and comfort. Units are equipped with rotary heat exchangers. They are very efficient, easy to mount and maintain and offer integrated automatic control, PLUG & PLAY. For full detailed information please contact Elta Fans. QUICK FACTS ü Domekt available m³/h. ü Efficient energy recovery thermal efficiency up to 90%. ü Easy installation due to extra compact size and universal inspection side. ü Silent operation. ü Integrated automatic control. ü Available in EC. KOMFOVENT VERSO NRVU Heat Recovery Unit heat recovery OVERVIEW The Komfovent VERSO Heat Recovery Units are designed to create healthy indoor air quality and comfort in hotels, schools, nurseries, offices, conference halls and other premises. They are very efficient, easy to mount and maintain. Units are available with Heat Recovery or as Supply only. For full detailed information please contact Elta Fans. QUICK FACTS ü Verso available m³/h. ü Energy efficient solution. ü Rotary Wheel & Plate Heat Exchanger available. ü Pre wired Plug & Play Concept with integrated controls. ü Integrated automatic control. ü Energy efficiency tested and approved by EUROVENT. 234 Tel: Fax: Visit: eltaselect.com

235 Smoke & Car Park Ventilation The ventilation level to be provided within a car park (in order to limit the concentration of carbon monoxide and other vehicle emissions and to remove smoke in the event of a fire) can be found in the relevant Building Regulations and in BS :2006 Components for smoke and heat control systems of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks. Elta Fans is a major supplier of axial flow fans for fresh air supply and extract as well as for emergency smoke ventilation systems. The SmokeVent range is specifically developed for general ventilation plus emergency smoke extract at either 200 C or 300 C for 2 hours using fans up to 2000mm in diameter or 400 C for 2 hours up to 1400mm in diameter. Elta can thus supply the main exhaust fans to operate in conjunction with the JetVent Induction fans. It is a mandatory requirement within the European Union that all smoke extract fans are independently tested to EN :2002 Smoke and heat control systems Specification for powered smoke and heat exhaust ventilators. This standard covers the testing, design and production controls that are required before the manufacturer can obtain product certification from the appropriate notified body. All Elta Fans emergency smoke extract fans are included on EC Certificate of Conformity 0086-CPD Smokevent LCS For for full technical information and much more, contact Elta Fans. Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 235

236 FAN SELECTION PROGRAM The Elta Fans Selection Program has been designed to make fan selection faster and more efficient. Developed from the ground up, the selection program makes it quicker and easier for you to select fans from our expansive range of products. Whether you ve used the program in a previously or if this is your first time, you will find this program a helpful part of your processes. Navigating the Program To navigate between the main areas of the program, simply use the main navigation buttons at the top. The program highlights the button to show which area of the program you are in. Basic Mode A dedicated Help source is available with the ability to define common default settings. Selecting a Fan Basic mode: allows you to use a 5 step process to determine suitable fans, or alternatively, use a single. Advanced mode: gives you complete control over the criteria for selecting your fan. Advanced Mode Silencers and Acoustic Analysis Silencer selection is available in both basic and advanced modes allowing a simple 5 step process to determine a suitable silencer or complete control over the criteria of the silencer type required. The Acoustic Analysis tool allows calculations on simple systems to be made to provide a rough approximation of what noise level can be expected. Our Fan Selection Program has become the essential software for consultants and contractors who want fast and accurate fan and silencer selections. Please contact Elta Fans for more information on Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com

237 FAN SELECTION PROGRAM Key Features The latest version has been designed to make it easier for you to select, compare and schedule fans and silencers with a number of powerful new features that will help you save time. ü A more user-friendly interface easier to find what you need based on a wide choice of criteria ü Basic and advanced user modes with guidance, use the program at the level that suits you ü Revolutionary support for variable speed fans helps you design more energy efficient systems Revolutionary Support ü Store all 2D.dwg and.dxf for a project in a folder in one quick step ü Conveniently view technical data in a single screen and recall it at any time ü Easily select energy efficient fans and calculate running costs ü Fully integrated PDF and Excel output promoting the efficient electronic flow of data and further compliment paperless offices Store All Files Convenient Data View PDF Output Select Efficient Fans Tel: Fax: bs@eltafans.co.uk Visit: eltaselect.com 237

238 With expertise in innovative fan design and manufacture dating back over 40 years. Bringing a continuum of product innovation and technical support focused on the needs of the customer. Today Elta Fans boasts a comprehensive range of standard and non-standard products for building services and residential applications. eltafans.com TM Idealair Group offer a wide range of standard products available immediately from stock to meet volume requirements, coupled with the ability to design and supply bespoke air distribution products to suit specific project requirements, idealair group can offer product guidance and provide the best solution available. idealairgroup.co.uk egbuildingservices..co.uk

239 Elta Group Building Services unites existing brands under one umbrella to create a singular, comprehensive portfolio of products. This range of highly competitive products will enable the business to satisfy larger and more diverse project specification, whilst extending the reach of their exceptional customer service operations. Air Design is an innovative manufacturer of air handling units (AHU) and heat recovery units (HRU) aimed primarily at the building services market, but also meeting the requirements of specialised applications. Operating from our dedicated engineering and production facility in the UK. air-design.com Hydor Building Services manufacture and supply cost effective products for residential, commercial and industrial applications, providing additional flexibility for specification clients and the wholesale market as completing the Elta Group Building Services portfolio with a unique range of washroom and hygiene products. hydor.co.uk/building-services

BIFLOW SB CON Product Brochure

BIFLOW SB CON Product Brochure BIFLOW SB CON Brochure Available for next day delivery with ELTA SELECT Bifurcated Conical Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

QUBE SQU-HT(S) Product Brochure

QUBE SQU-HT(S) Product Brochure QUBE SQU-HT(S) Product Brochure Available for next day delivery with ELTA SELECT Centrifugal Box Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy

More information

TWINFLOW STDR Product Brochure

TWINFLOW STDR Product Brochure TWINFLOW STDR Brochure Available for next day delivery with ELTA SELECT Direct Drive Twin Centrifugal Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

REVOLUTION SLCX Product Brochure

REVOLUTION SLCX Product Brochure REVOLUTION SLCX Brochure Available for next day delivery with ELTA SELECT ATEX Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

ISEO IMF Product Brochure

ISEO IMF Product Brochure ISEO IMF Product Brochure Available for next day delivery with ELTA SELECT In-Line Mixed Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy

More information

CLASSIC SAX Window / Wall Mounted Axial Fan. Select models available for next day delivery

CLASSIC SAX Window / Wall Mounted Axial Fan. Select models available for next day delivery Window / Wall Mounted Axial Fan Select models available for next day delivery Product Overview 2 standard sizes 230mm and 305mm Air volume flow rates up to 0.53 m³/s Static pressures up to 80 Pa Suitable

More information

MULTIFLOW SEL Product Brochure

MULTIFLOW SEL Product Brochure MULTIFLOW SEL Product Brochure Available for next day delivery with ELTA SELECT Mixed Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency

More information

ZOO FAN SDF Destratification Ceiling Mounted Fan

ZOO FAN SDF Destratification Ceiling Mounted Fan Destratification Ceiling Mounted Fan Overview 2 standard sizes from 250mm to 300mm Air volume flow rates up to 0.593m³/s (AC) and 0.656m³/s (EC) High quality Ziehl-Abegg FE2owlet impeller Suitable for

More information

BOX BLB Centrifugal Box Fan

BOX BLB Centrifugal Box Fan Centrifugal Box Fan Select models available for next day delivery Product Overview 3 sizes from 260mm to 400mm Air volume flow rates up to 0.751m³/s Static pressures up to 733 Pa Suitable for operating

More information

TURBOFLOW TF Contra Rotating Axial Flow Fan

TURBOFLOW TF Contra Rotating Axial Flow Fan TURBOFLOW TF Contra Rotating Axial Flow Fan Select models available for next day delivery TURBOFLOW TF Overview 5 standard sizes from 450mm to 630mm Air volume flow rates up to 4.6 m³/s Static pressures

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

Bifurcated Case Axial Fans (BIFA)

Bifurcated Case Axial Fans (BIFA) Bifurcated Case Axial Fans (BIFA) Sizes 250 to 1000 dia Motors protected to IP55 Motor insulation Class F Maximum ambient temperature 200 C Speed controllable via transformer or inverter (when the ambient

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT

MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT AIR COMFORT FIRE SAFETY AIR MOVEMENT MAXFAN COMPAC» OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL INTRODUCING THE MAXFAN COMPAC THE NEW MAXFAN COMPAC DESIGNED FOR THE KITCHEN CANOPY MARKET

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range Twin and Single Inline Fans Offers a range of flexible installation and application options, including auto-changeover on the Twin range 2 Version 3.1 Breathing Buildings Inline Box Fans Demand Control

More information

Plate mounted axial flow fans HXBR / HXTR Series

Plate mounted axial flow fans HXBR / HXTR Series Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester

More information

Max. airflow m 3 /s Diam. min. Diam. max

Max. airflow m 3 /s Diam. min. Diam. max Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89

More information

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS OUR COMMITMENT TO THE ENVIRONMENT Sodeca has begun a new stage of study and design of new trends in ventilation which will help to preserve the environment and

More information

NEW Slimpak EC Box Fan (SLPT EC)

NEW Slimpak EC Box Fan (SLPT EC) NEW Slimpak EC Box Fan (SLPT EC) Compact low profile design Duct Sizes 100 500mm Performance - Airflow 0.01 to 1.2m 3 /s, Pressure up to 650Pa Latest energy saving EC/DC motors Internal mounting IPX2 Manufactured

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

Size and Configurations

Size and Configurations !!"#!""!"$%!!" &'()&('& AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

Ultra-reliable cooling technology is in our DNA

Ultra-reliable cooling technology is in our DNA www.howden.com Ultra-reliable cooling technology is in our DNA Fans and cooling systems that keep the world s rail transport running In an industry where safety is paramount and reliability is essential,

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range CI/SfB (57.7) 1st Edition from Vent-Axia Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range Energy Recovery Ventilation (ERV) Range Building on the success of the Sentinel Totus 2 range

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

LC/SC. Long & Short Cased Axial Fans

LC/SC. Long & Short Cased Axial Fans LC/SC Long & Short Cased xial Fans LC/SC contents introduction features & benefits specification performance dimensional data mounting silencer data accessories inverters & DCV controllers additional

More information

ExpressBuild STANDARD FAN RANGE

ExpressBuild STANDARD FAN RANGE AIR COMFORT FIRE SAFETY ExpressBuild STANDARD FAN RANGE OUR SHORT LEAD TIME FAN RANGE ExpressBuild CONCEPT & PRINCIPLES When a short lead time solution is important, choose an ExpressBuild Fan product

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

Uniclass L7534. Manufacture controlled to ISO9001

Uniclass L7534. Manufacture controlled to ISO9001 CABINET & TWIN FANS FOR INDUSTRIAL / COMMERCIAL USE "ACFS" - Quiet Duct Centrifugal - Single Fan "DMTSQ" - Quiet Duct Centrifugal - Twin Fan "RMS" - Roof Centrifugal - Single Fan "RMTS" - Roof Centrifugal

More information

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour 1.0 Introduction The Nuaire Axus range of Long Cased Axial Flow Fans are produced in sixteen case sizes from 315mm dia. to 1600mm dia. with duties up to 65m3/s. Impellers are manufactured in aluminium

More information

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications. EuroSeries (ESR) Cowl & base moulded from recyclable polymeric material All sizes resistant to UV light Sizes 250 to 1000 dia are protected to IP54 Optional backdraught shutters and bird guard (250-630mm)

More information

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant infinity AIR VENT T E C H N O L O G Y energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant INDEX Selection Chart Page 3 Internal & External Acoustic

More information

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive

More information

JM Aerofoil Multi-Stage 50 Hz

JM Aerofoil Multi-Stage 50 Hz JM Aerofoil Multi-Stage 5 Hz JM AEROFOIL - MULTI-STAGE CONTENTS Page: JM Aerofoil Multi-Stage - Introduction -5 Multi-Staging Motor Frame Size Schedules - Three Phase 7-8 Performance Curves SK1- SK135

More information

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices Aerofoil Ventilation Fans Quality & Performance at Affordable Prices GENERAL FEATURES, located in Chennai strives to deliver quality products at affordable costs to all its customers. Our company s vision

More information

Section 4 e c tio - P lat F a n s

Section 4 e c tio - P lat F a n s Plate Fans Section 4 The Fläkt Woods Plate Fan Range is the result of detailed market analysis and intensive research and development by the world leaders in air movement technology. By setting and achieving

More information

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS Cabinet Fan SV-1 INDEX INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART pages 01 02 03 04 DIMENSION SHEET - SINGLE CABINET FANS DIMENSION SHEET - TWIN CABINET FANS PERFORMANCE GRAPH WIRING

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

High Performance Axial Fans

High Performance Axial Fans High Performance Axial Fans Model RA Standard and High Temperature High Efficiencies Low Sound January 2014 High Performance Axial Fans Greenheck s model RA, high performance, direct-driven axial fans,

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR 13 POWERBOX EC FANS - ESTOC EC FEATURES Sizes from 3 to 3 mm diameter Air flow up to.1 m 3 /s Static pressures up to Pa Controllable EC motors Multiple outlet orientations ELECTRICAL SUPPLY 22-2V/Hz/1f

More information

QUIETSCROLL TWIN FAN RANGE

QUIETSCROLL TWIN FAN RANGE QUIETSCROLL TWIN FAN RANGE MOST COMPREHENSIVE RANGE OF TWIN FANS WITH INTEGRAL ENERGY- SAVING CONTROLS NUAIRE. FOR THE COMPLETE VENTILATION SOLUTION UK MADE QUIETSCROLL TWIN FANS QUIETSCROLL TWIN FAN RANGE

More information

BRIZA 22 HYBRID HEATING & COOLING

BRIZA 22 HYBRID HEATING & COOLING BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe

More information

Sentinel D-Box Single Fan

Sentinel D-Box Single Fan Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

Medium Pressure Centrifugal Fans

Medium Pressure Centrifugal Fans Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock

More information

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features and Benefits In-line, Belt Driven, compact centrifugal twin fan. High Quality Heavy Gauge Galvanised Steel Casing. Optional IP65 Service

More information

SQUIF HIGH TEMPERATURE FANS

SQUIF HIGH TEMPERATURE FANS FNS HIGH TEMPERTURE CENTRIFUGL SQUIF FOR SMOKE EXTRCT CERTIFIED TO EN12101-3-2002. 366 029 2085 8200 BENEFITS HIGH TEMPERTURE PPLICTION Capable of running continuously at 90ºC, ideal for kitchen canopy

More information

Sapphire Horizontal Waterside Control Fan Coil Units

Sapphire Horizontal Waterside Control Fan Coil Units Sapphire Horizontal Waterside Control Fan Coil Units Introduction The Quartz SAPPHIRE series is a compact, high output fan coil unit capable of meeting exacting heating and cooling requirements whilst

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

something new in the air Technical Bulletin

something new in the air Technical Bulletin something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological

More information

Wide performance ranges are obtained by using three impeller designs to suit all types of applications.

Wide performance ranges are obtained by using three impeller designs to suit all types of applications. Roof Mounted Fans Section 6 Wide performance ranges are obtained by using three impeller designs to suit all types of applications. The roof extract units are designed to satisfy the consultants functional

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

SILENT MV Ultra Quiet In-line Fans

SILENT MV Ultra Quiet In-line Fans Ultra Quiet In-line Fans 5 IP44 2 YEAR GUARANTEE Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,

More information

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016 Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

Acoustic Twin Fans (ATQ)

Acoustic Twin Fans (ATQ) Acoustic Twin Fans (ATQ) Features and Benefits Available in sizes from 100 to 500mm dia 50mm Acoustically treated housing, Class O rated, self extinguishing, zero burn rate, resists ignition, no toxic

More information

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1) Industrial and commercial ventilation (Catalogue no. 1) Industrial and commercial ventilation components - fans for round and rectangular ducts, sound-insulated, axial and roof fans, air handling units

More information

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA KVA POWERHOUSE RANGE 1250 KVA 1700 KVA 50 hz Three phase 380-415 v Model Engine Alternator Manufacturing country of engine & alternator PRP Output ESP Output Kva Kw Kva 380v/400- Kw 415v 46TWG2A PI734B

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

SLCX ATEX LONG CASED AXIAL FLOW FAN PLEASE CONTACT AERAULIQA DIRECLTY FOR A SPECIFIC FAN SELECTION ACCESSORIES APPLICATION FEATURES & BENEFITS

SLCX ATEX LONG CASED AXIAL FLOW FAN PLEASE CONTACT AERAULIQA DIRECLTY FOR A SPECIFIC FAN SELECTION ACCESSORIES APPLICATION FEATURES & BENEFITS ATEX LOG ASE AXAL FLOW FA ALATO ATEX ucted Axial Flow Fans suitable to exhaust/supply air in presence of chemical processes, water and sewage treatment, material and gas waste, dust and paint extraction,

More information

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS External roof mounted single fan unit manufactured from aluzinc. 7.111 +44 (0) 29 2085 8515 BENEFITS Hard wearing on site External single fan unit manufactured

More information

CYLINDRICAL CASED AXIAL FLOW FANS

CYLINDRICAL CASED AXIAL FLOW FANS - Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate

More information

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Galaxy TM In-Line Belt Driven Twin Fans (GDB) Galaxy TM In-Line Belt Driven Twin Fans (GDB) Features & Benefits In-line, Belt Driven, compact centrifugal twin fan High Quality Heavy Gauge Galvanised Steel Casing Optional IP65 Service Isolator Motor

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

Multi directional heating. Air heaters Model NOZ

Multi directional heating. Air heaters Model NOZ Multi directional heating Air heaters Model NOZ Air heaters The ideal heat source for large buildings Air heaters are used for the heating and ventilation of large industrial buildings. New industrial

More information

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series C. October CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series WTC Centrifugal Fans & AMCA Certification WTC Tech

More information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with

More information

Kitchen exhaust fan GLEB

Kitchen exhaust fan GLEB Kitchen exhaust fan GLEB Contents General description...3 Quick selection...5 Design description...5 Material and design...6 Fan impeller...6 Motor...6...6 Quality...6 Specification...6 Technical data

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE CIL - Centrifugal In-Line Fans SBAF - Slimbox Acoustic Fans ACF - Acoustic Cabinet Fans - Direct Drive ACFS - Super-Silent Acoustic Cabinet Fans

More information

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology HANDLERS LTD AHTW Compact Heat Recovery Air Handling Unit 1262 Acoustic Testing Laboratory College of Science & Technology BIM & REVIT Engineering Solutions The Company Air Handlers has been trading since

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

low carbon centrifugal Pod blowers

low carbon centrifugal Pod blowers low carbon centrifugal Pod blowers torin-sifan For over 100 years, torin-sifan have been a leader in servicing the Air Movement requirements of our customers. From our Head Office and Manufacturing facility

More information

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE ELECTRIC HEAT PUMP PACKAGED UNITS MHP4 FORM NO. MHP4-100 (10/2018) MODEL NUMBER GUIDE 3 M HP 4 11 18 1 F P 1 FACTORY INSTALLED ELECTRIC HEAT 3= 3 KW 5 = 5 KW 7 = 7 KW 10 = 10 KW M = MAGIC-PAK HP = HEAT

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS - ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate

More information

BIFURCATED AXIAL FANS

BIFURCATED AXIAL FANS BFURATE AXAL FAS SB (YL) ALATO SB (O) Bifurcated axial fans suitable to move air in hostile applications, for example in case of dust and chemical substances in heavy industrial, boiler houses, corrosive

More information