1 MGV25.X USER GUIDE INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.X Ver. 3.1 MONTANARI GIULIO & C. S.r.l MODENA (Italy) Via Bulgaria,39 Tel Fax Cap.Soc i.v. Export MO R.E.A. di MO N Reg.Imprese di MO Cod.fisc. e Part.IVA n Identification CEE No. IT info@montanari-giulio.com

2 Aim The aim of this manual is to provide instructions for the correct installation, use and maintenance of the GEARLESS type MGV25.2, MGV25.3 and MGV25.5 for use in passenger and freight lifts. Warning: This booklet does not contemplate the instructions for the shutting down of the entire system, but only the instructions relating to the GEARLESS, therefore before starting the installation of the gearless you must follow the instructions in this operation and maintenance manual and take precautions in accordance with the current safety standards. The Gearless motors MGV25 and all the components supplied by Montanari Giulio & C, have been tested in order to guarantee their correct operation. The Gearless motor has been tested in both empty and loaded operating conditions, in accordance with the technical specifications for velocity, car capacity load, car weight, presence or not of compensation and the type of roping requested when the order was placed. This ensures the correct operation and a minimum number of set-up operations. All responsibility is declined for any malfunctions due to installation with different characteristics, except in the case of specific approval by Montanari G. & C.

3 Summary: 1. References Standard 2 2. General notes 2 3. Transport 2 4. Warehouse storage 3 5. Installation 3 6. Use Maintenance Declaration of Conformity Brake Certificate 14 1

4 MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l 1 References Standard. 1.1 The following standards are to be considered as references and are not necessarily entirely applicable to this technical instruction. (Table 1) N Reference Type of standard Description 1 UNI E Maintenance : Terminology 2 UNI EN 81/1 E Safety rules for the construction and installation of passenger and freight lifts Table 1 2 General Notes. 2.1 The operations described in this manual must be carried out by qualified personnel, equipped with the necessary workshop tools. 2.2 Before all interventions the entire system must be put out of commission to prevent it from being used. 2.3 For all requests for spare parts or for particular instructions it is always necessary to specify the serial number, which can be found stamped next to the electrical connection terminal board. 3 Transport. 3.1 The entire gearless are packed in cases or crates. In some cases they are mounted upon wooden platforms, in order to be transported correctly on the lorry. The cases and crates are not load bearing and therefore cannot be stacked upon each other. 3.2 The unloading of the material, from the transport vehicle, must be done with equipment that is suitable for both the weight and the dimensions of the load. All the packing is designed for movement by fork lift and low lift platform trucks. 3.3 Upon the receipt of all material, check its condition. In the event of any damage do not proceed with the installation unless authorised otherwise by Montanari Giulio & C. 2

5 19/02/2013 Ver Warehouse storage. 4.1 Preserve the gearless, even if it is still packed, in a dry place where it is protected from bad weather. 4.2 Once the packing has been removed take the necessary precautions to avoid the settling of any dust. 5 Installation. 5.1 Operating Conditions. - The gearless machine must be installed in a building or closed hoist-way. - Do not operate the gearless in an explosive atmosphere. - The ambient temperature must be within 0 C and +40 C. 5.2 Handling. The gearless MGV25 can be lifted using the holes already present on the base for the fitting of belts or chains. (Figure N 1) Lifting sample: Figure 1 Care must be taken to ensure that the gearless doesn t get knocked as the brake disc, the brake callipers and the electrical connection terminal board are particularly delicate. 3

6 MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l 5.3 Assembly. The gearless are ideal for assembly either with or without a machine room. The roping and therefore the load must always be orientated versus the base of the machine as shown in the diagram. (Figure N 2) MGV25.2 MGV25.3 MGV25.5 Figure 2 In the case of assembly with the machine down, and therefore with the roping and load upward, you must mount it rotated by 180 degrees. (Figure N 3) MGV25.2 MGV25.3 MGV25.5 Figure 3 4

7 19/02/2013 Ver Gearless Dimension. MGV25.3 MGV25.5 Figure 4 MGV25.3 MGV25.5 Figure 5 MGV25.3 MGV25.5 Figure 6 5

8 MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l MGV25.2 Figure 7 Figure 8 Figure 9 6

9 19/02/2013 Ver Brake. The gearless is provided with a disc brake that is operated by 2 independent electromechanical devices which are conform to the EN81-1 standard. The gripping calipers are pre-calibrated by the manufacturer and therefore don t require any further adjustment. In attachment, we send the technical documentation of the brake, with the procedure of maintenance, regulation and electrical connection installation. Attention must be paid and if necessary precautions taken to ensure that oil or grease do not come into contact with the brake disc. Grease or oil on the brake disc can jeopardise the braking and put people in serious danger. 5.6 Lubrication. The gearless does not contain oil and is supplied with bearings that are lubricated for the life of the equipment; therefore no further lubrication is necessary. 5.7 Electric installation. The gearless is directly supplied with cable, with inside three cables for phases (1,2,3), two cables for cooling fan supply (230Vac between F7 and F8), two cables for the Thermistors PTC (T5, T6), one ground cable and one cable for shield (gray cable). (See image below) Figure 10 7

10 MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l Temporiti s Brake: (For MGV25.2 and MGV25.3 machines) The cables of the brake supply and micro switches must be connected separately. For information about supply the brake, see the label on the brake. For the micro switches, are represent from two contacts, one Normally Open (N.O.) and one Normally Close (N.C.) (See Figure 10). In rested state the gearless brake is closed and there isn t voltage in the coil (Figure 8). In this condition all lift system is motionless. When motor receive a command of moving, the coil is supplied and the brake disk is free changing the status from closed to open and hence the micro switch does the same (Figure 9). Brake disk M1 Coil Coil Micro switch M2 Figure 11 Brake Closed Figure 12 Brake Open For the operating principle of the micro switches M1 and M2 see the table 2. For example: micro switch M1; when brake is close, it s open;but when brake is supplied changing in off status. N.C N.O Com Brake Closed/Stuck Contact Type Status Contact Figure 13 Brake Open/Free Contact Type Status Contact N.O. - M1 Disconnected N.O. - M1 Connected N.O. - M2 Disconnected N.O. - M2 Connected Table 2 8

11 19/02/2013 Ver.3.1 Intorq s Brake: (For MGV25.5 machines) As Temoriti s brake, the cables of the brake supply and micro switches must be connected separately, but, this brake has to be supplied with Booster device in order to give 207 VDC for 1 second while opening and hold at 104 VDC. See Booster Basic Manual for further information. Figure 14 Brake Closed Figure 15 Brake Open The operating principle of the micro switches is different from Temporiti s brake; in rested state the gearless brake it s closed (Figure 11), and the contact normally open of the micro switch M1 and M2 is open(open circuit). When we will open the brake (Figure 12), all two micro switches changing that status in closed (short circuit). In the Table 3 is explained how to works the contacts of the micro switches M1 and M2. M1 Brake Supply Micro switch M2 Brake Closed/Stuck Contact Type for M1 and M2 Status Contact Figure 16 Brake Open/Free Contact Type for M1 and M2 Status Contact N.O. Disconnected N.O. Connected N.C. Connected N.C. Disconnected Table 3 9

12 MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l GEARLESS MGV25 TECHNICAL CHARACTERISTICS Motor Type Pn [kw] Speed [Rpm] Vn [V] Cn [Nm] In [A] Cmax [Nm] Imax [A] Emf [V*s/rad] Poles [n ] F [Hz] R [Ohm] L [H] St. Load [Kg] I [kgm^2] Duty Cycle Weight [Kg] Typical Installation MGV % 180s/h Kg 2:1 0.63m/s 320mm MGV % 180s/h Kg 2:1 1m/s 320mm MGV % 180s/h Kg 2:1 1.5m/s 320mm MGV % 180s/h Kg 2:1 1m/s 320mm MGV % 180s/h Kg 2:1 1m/s 320mm MGV % 180s/h kg 2:1 1.5m/s 320mm MGV % 180s/h Kg 2:1 1.5m/s 320mm MGV % 180s/h Kg 2:1 1m/s 320mm MGV % 180s/h Kg 2:1 1.5m/s 320mm Table 4 10

13 19/02/2013 Ver Use 6.1 General notes. The gearless are designed and constructed as lifting devices for lifts and hoists and respect the various sector standards. Any other use is to be considered improper. They cannot be used in systems with characteristics that are different to those agreed upon in the order (e.g. carrying capacity, velocity, etc.), Qualified and competent personnel must carry out all tests, inspections or manoeuvres that may be necessary in accordance with the current standards. 6.2 Emergency manoeuvre. The emergency maneuver must be made by an independent electrical device, which is capable of opening the brake and moving the gearless at a reduced velocity. It is possible to exploit the characteristics of the synchronous motor as it can slow down the car when the phases are put into short circuit. This system has some load limits and it is therefore necessary to observe several precautions. Montanari Giulio & C. can provide the information necessary to apply the aforementioned solution upon request. 7 Maintenance 7.1 Traction/Driving pulley. Periodically, at least once a year, check the amount of wear on the cable races on the traction pulley. In the event of the cables slipping or of excessive wear contact Montanari Giulio & C. for the substitution instructions, always indicating the serial number. 11

14 MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l 7.2 Component substitution. The instructions for any eventual component substitutions must be asked for each time from the Technical Department, specifying the serial number. 12

15 19/02/2013 Ver Declaration of Conformity. DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY (Directive 2006/42/CE, Annex II, par. B.) Manufacturer: Montanari Giulio & C. S.r.l. Via Bulgaria n.39, Modena Person authorised to compile the relevant technical documentation: Bertoni Stefano, via Pagani 133/3, Modena Model of the partly completed machinery: Gearless: MG200 MG250 MG300 - MG340 MCG150 MDD35 - MDD70 The essential requirements of this Directive are applied a fulfilled and the relevant technical documentation is compiled in accordance with part B of Annex II. The partly completed machinery comply with the following directives: 95/16/CE, 89/336/CE, 92/31/CE, 73/23/CE The Montanari Giulio & C. S.r.l. undertakes to provide, in response to a reasoned request by national authorities, relevant information on the partly completed machinery. The partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of this Directive: 2006/42/CE or 95/16/CE. Violation of the dispositions given in these technical instructions will immediately invalidate any form of guarantee Note: With regard to fulfilment of point 9.7 of reference regulation EN , please remember that Montanari supplies protection devices only if specifically requested by the customer. The responsible Ponanti Graziano Firma: Modena il 22/12/

16 MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l 9 Brake Certificate. The brake has been designed in conformance with the specific requests of the EN81-1 standard. This device is therefore usable as a brake to slow down the car in combination with a suitable speed governor in the case of excessive velocity in the rising direction. The examination certificate is an ABV817 type and is issued by TÜV B.B. Temporiti s Certificate: 14

17 19/02/2013 Ver

18 MGV25 USER GUIDE MONTANARI GIULIO & C. S.r.l Intorq s Certificate: 16

19 19/02/2013 Ver

20 MONTANARI GIULIO & C. S.r.l MODENA (Italy) Via Bulgaria,39 Tel Fax Cap.Soc i.v. Export MO R.E.A. di MO N Reg.Imprese di MO Cod.fisc. e Part.IVA n Identification CEE No. IT info@montanari-giulio.com Manuale_MGV25_ENG_Vs3_1

MGV25.X USER GUIDE. Ver. 3.7 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5

MGV25.X USER GUIDE. Ver. 3.7 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5 MGV25.X USER GUIDE INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5 Ver. 3.7 MONTANARI GIULIO & C. S.r.l. 41100 MODENA (Italy) Via Bulgaria,39 Tel. +39 059 45.36.11

More information

MG300 USER GUIDE. Ver. 3.2 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MG300.4, MG300.6, MGV30.4 AND MGV30.6

MG300 USER GUIDE. Ver. 3.2 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MG300.4, MG300.6, MGV30.4 AND MGV30.6 MG300 USER GUIDE INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MG300.4, MG300.6, MGV30.4 AND MGV30.6 Ver. 3.2 MONTANARI GIULIO & C. S.r.l. 41100 MODENA (Italy) Via Bulgaria,39 Tel. +39

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16 Installation manual ASTER AUTOMATION FOR SWING GATES 11_16 Contents 1. GENERAL SAFETY PRECAUTIONS... page 01 2. INTENDED USE AND APPLICATION... page 01 2.1 Kit contents... page 01 2.2 Technical features...

More information

Montanari Giulio & C. s.r.l.

Montanari Giulio & C. s.r.l. Montanari Giulio & C. s.r.l. Montanari Giulio produces a complete range of gears and accessories for lies; Categories index GEARS ACCESSORIES FOR GEARS TRACTION SHEAVES FLY- WHELLS MOTORS ELETTRONICA Montanari

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

Position Limit Switches PLTA

Position Limit Switches PLTA Position Limit Switches PLTA PLTA PLTA is a position limit switch designed to control overhead travelling cranes, hoists and machine tools. It operates as auxiliary controller of electrical motors through

More information

BOX A3 TEST REL. DATE R.T. Check and Approval

BOX A3 TEST REL. DATE R.T. Check and Approval BOX A3 TEST 3 20-07-2012 REL. DATE R.T. Check and Approval INDEX 1 - FOREWORD......Page 3 2 - BOX A3 TEST FOR HYDRAULIC LIFTS...Page 3 2.1 GENERAL OPERATION...Page 3 2.2 HOW THE CHECK OF THE VALVE HYDRAULIC

More information

Hollister-Whitney Elevator Corporation

Hollister-Whitney Elevator Corporation Hollister-Whitney Elevator Corporation Installation and Service Manual GL101, GL131, GL171, GL130A, GL185 and GL260 AC Permanent Magnet, Gearless Machines Page 1 of 32 Table of Contents I. Introduction

More information

USER INSTRUCTIONS FOR SLIDING DOORS

USER INSTRUCTIONS FOR SLIDING DOORS ENGLISH USER INSTRUCTIONS FOR SLIDING DOORS SL3L LIGHT SL4A ADVANCED SL5A ADVANCED SL5H HEAVY SLTA TELESCOPIC-ADVANCED SL4E EMERGENCY SL5E EMERGENCY SL5B BIG SLTE TELESCOPIC-EMERGENCY FACE S.p.A. Viale

More information

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS TABLE OF CONTENTS 1.0 - WARNINGS 2.0 - GENERAL DATA 2.1 - Technical characteristics 2.2 - Data on electrical

More information

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT Page 1/38 Safety Valve HSV Installation, maintenance and startup guide HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT Page 2/38 2011 by Hydronic Lift Spa All right reserved. This documentation, in whole and/or

More information

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Electrically Released Brakes ERS VAR11-01 FT = 4100 N SM429gb - rev 06/11 S E R V I C E Electrically Released Brakes ERS VAR11-01 FT = 4100 N M A N U A L EC type certificate ABV 775/1 According to drawing 1 12 106946 TUV SUD Industrie Service WARNER ELECTRIC

More information

BELT CONVEYOR CB/M5 Series

BELT CONVEYOR CB/M5 Series BELT CONVEYOR CB/M5 Series User and maintenance manual 1 DECLARATION OF CONFORMITY The company: Tel. +39-0444 450 620-451 520 Fax +39-0444 671 840 declares under its own responsibility that the machine

More information

OPERATION & MAINTENANCE MANUAL SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L

OPERATION & MAINTENANCE MANUAL SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L OPERATION & MAINTENANCE MANUAL 3005/ /12 en Ed. 01 1.2012 SYNCHRONOUS GEARLESS MACHINES T32S/T32/T32L CONTENTS 1. SAFETY RULES 1.1. General safety instructions 1.2. Safety precautions 1.3. Intended use

More information

Automatic concealed bollards 275 H600 and 275 H800 with pit

Automatic concealed bollards 275 H600 and 275 H800 with pit Automatic concealed bollards 275 H600 and 275 H800 with pit Technical installation manual CE Declaration of conformity Warnings for the installer Bollard technical data Preparing and installing the bollard

More information

GREENSTAR CANTIELEVER. User Guide. v4 - English

GREENSTAR CANTIELEVER. User Guide. v4 - English GREENSTAR CANTIELEVER User Guide v4 - English Content 1 General Information 1.1 Greenstar 1.2 Objective 1.3 Copyrigth 1.4 Safety 2 Technical Information 2.1 Mounting 2.1.1 Functions 2.1.2 Nomenclature

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

BAH series Use and Maintenance Manual

BAH series Use and Maintenance Manual Page 1 of 15 BAH 225-280 series Use and Maintenance Manual Page 2 of 15 We would like to thank you for trusting us and buying our product. Field of application Before starting the motor, it s necessary

More information

Certificate of Incorporation (Typical)

Certificate of Incorporation (Typical) Certificate of Incorporation (Typical) Declaration We Varley Pump Limited hereby declare that the following machinery has been designed to be safely incorporated into other machinery and must not be put

More information

Explosion and flame-proof cast iron electric motors

Explosion and flame-proof cast iron electric motors Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting

More information

BELT CONVEYOR PNL/4 Series User and maintenance manual

BELT CONVEYOR PNL/4 Series User and maintenance manual BELT CONVEYOR PNL/4 Series User and maintenance manual 1 DECLARATION OF CONFORMITY CE In conformity with the 2006/42/CE Machine Directives, Enclosure II, section A The company: VIRGINIO NASTRI S.r.l. Tel.

More information

IP 900 W/KS & IP 900 D/KS

IP 900 W/KS & IP 900 D/KS B W/KS & D/KS Installation and operating instructions We reserve the right to make modifications in the interest of technical development (4) 15975178 GB 04/05 1 pplication reas The submersible waste-water

More information

Crane fork KGM/KGA and KGQ/KGL

Crane fork KGM/KGA and KGQ/KGL Crane fork KGM/KGA and KGQ/KGL Operating manual This equipment must not be installed, operated or maintained by any person who has not read and understood all the contents of this manual - 1 - Table of

More information

Electrically Released Brakes ERS VAR10 SZ 5000/5000

Electrically Released Brakes ERS VAR10 SZ 5000/5000 SM366gb - rev 01/06 S E R V I C E Electrically Released Brakes ERS VAR10 SZ 5000/5000 M A N U A L EC type certificate ABV 604/1 according drawing 1 12 106602 WARNER ELECTRIC EUROPE Rue Champfleur, B.P.

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

User Guide AMF Floor / Portrait Adaptor

User Guide AMF Floor / Portrait Adaptor User Guide AMF100200 Floor / Portrait Adaptor SAFTEY INFORMATION These instructions should be handed over to the person carrying out the installation. 1. Only a qualified technician should carry out installation

More information

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03 INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR469000 OR25 REV03 I II CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment

More information

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference! Tension Meter FT Series S C H M I D T c o n t r o l i n s t r u m e n t s Edition FT 03.E Model FT Instruction Manual Valid as of: 01.09.2011 Please keep the manual for future reference! Contents 1 Warranty

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

New Machinery Directive

New Machinery Directive New Machinery Directive Machinery Directive 2006/42/EC Member States to adopt and Publish 29 th June 2008 Directive applies in full 29 th December 2009 This Directive now looks at the lifecycle of the

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION 770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the

More information

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY Sheet n 1 of 20 WATER DRAW/ MASTER METER PETROL COUNTER MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL PETROL INSTRUMENTS S.r.l. - 04011 APRILIA (LT) - ITALY Sheet n 2 of 20 INSTALLATION, USE AND SERVICE

More information

Explosion and flame-proof single phase electric motors

Explosion and flame-proof single phase electric motors Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting

More information

VA-7450 Series. Electric Valve Actuators

VA-7450 Series. Electric Valve Actuators 34-636- 771, Rev. D Installation Instructions VA-7450 Series Issue Date 0216 VA-7450 Series Electric Valve Actuators Applications VA-7450 Series Electric Valve Actuators provide on/off, floating, or proportional

More information

NPA-CP Pendant Control Station

NPA-CP Pendant Control Station NPA-CP Pendant Control Station Pendant station for direct control of industrial machines. Sturdy and handy, NPA-CP is specifically designed for heavy duty in industrial environments. FEATURES The cable

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax V2 S.p.A. Corso Principi di Piemonte, 65/67 12035 RACCONIGI (CN) ITALY tel. +39 01 72 81 24 11 - fax +39 01 72 84 050 info@v2home.com - www.v2home.com IL n.131 EDIZ. 28/08/2012 Bingo I GB F E P D NL ATTUATORE

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 770

More information

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4DL. Guard Lock Safety-door Switch. Model Number Structure Guard Lock Safety-door Switch Two new types added to series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage is applied

More information

MV Series Motors Operation & Parts Manual

MV Series Motors Operation & Parts Manual MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson

More information

Pump Series 999 DROPSA SpA In accordance with point 1.7.4, to I, Dir 98/37 CE

Pump Series 999 DROPSA SpA In accordance with point 1.7.4, to I, Dir 98/37 CE Pump Series 999 DROPSA SpA In accordance with point.7.4, to I, Dir 98/37 CE INSTRUCTIONS FOR USE Sections: 0.0 INTRODUCTION.0 DESCRIPTION OF THE PUMP.0 TECHNICAL SPECIFICATIONS 3.0 CORRECT USE 4.0 INSTRUCTIONS

More information

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION 1. GENERAL INFORMATION The MICROSOL intrinsic safety solenoid valves produced by Fluid Automation Systems SA are dedicated to piloting fluids in explosive atmospheres according to the ATEX 94/9/CE directive,

More information

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00 INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR469100 BR25AT REV00 I CONTENT: 1 SAFETY 1.1 Safety instructions 1 1.2 Specified applications 1 1.3 Safety notes on the equipment operation 1 2 BR 25

More information

NPA-CP. Pendant control station. OPtiONs. FeAtures. CertiFiCAtiONs

NPA-CP. Pendant control station. OPtiONs. FeAtures. CertiFiCAtiONs Pendant control station NPA-CP Pendant station for direct control of industrial machines. Sturdy and handy, NPA-CP is speciically designed for heavy duty in industrial environments. FeAtures The cable

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

Solenoid Operator 0516 / 1216

Solenoid Operator 0516 / 1216 nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

Charlie Pendant Control Station

Charlie Pendant Control Station Tecno Elettrica Ravasi Charlie pendant station is a control device for all industrial machinery. It operates as an auxiliary controller of electrical motors through a power interface, such as a contactor

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack UNDERGROUND OPERATOR FOR SWINGING GATES COMPAS 2 WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack Our products if installed by qualified personnel capable to

More information

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS Super ELF-X2 USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS SUPER ELF X2 WARNING! - Condensation could form on the Weft Feeder when it is moved from the cold environment of the warehouse to

More information

Quick Start. Flat head screwdriver. Wheel carriage x 2. M8 Nut x 2. Strap Bolt x 2. 1 x 2m Anodised Track

Quick Start. Flat head screwdriver. Wheel carriage x 2. M8 Nut x 2. Strap Bolt x 2. 1 x 2m Anodised Track Evolve 80 Glass FITTING INSTRUCTIONS - NOTICE DE POSE - MONTAGE HANDLEIDING - MONTAGEANLEITUNG ISTRUZIONI DI MONTAGGIO - INSTUCCIONES DE MONTAJE 80kg Maximum Weight = 80kg - Maximum Door Width = 1100mm

More information

Solenoid Operator 0513 / 1213

Solenoid Operator 0513 / 1213 nass magnet GmbH Run Nr. 5 Eckenerstraße 4-6 24.10.2006 D-30179 Hannover Rev. 5 061024 Solenoid Operator 0513 / 1213 Operating Instructions NN 8220 112 and EC Declaration of Conformity Dear Customer! In

More information

OPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO

OPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO OPERATING INSTRUCTIONS ASTRO HOIST Type E89-CTO CONFORM TO EN 1808 - MARCH 1999 MACHINE DIRECTIVE 98/37 EC All persons operating this equipment must read and completely understand this manual. Any operation

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

INSTRUCTIONS FOR INSTALLATION

INSTRUCTIONS FOR INSTALLATION HYDRAULIC OPERATOR MODO 110-110/L FOR SINGLE- OR DOUBLE-WING SWING GATES INSTRUCTIONS FOR INSTALLATION GENERAL WARNINGS These warnings constitute an integral and essential part of the product and must

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

Disclaimer: This brochure is for information only. The manufacturer reserves the right to modify specifications.

Disclaimer: This brochure is for information only. The manufacturer reserves the right to modify specifications. USER MANUAL 2 3 Table of contents 4-5 6 7 8 9 10 11 12 Safety recommendations elebia autohook system / Installation Main features Specifications / Regulatory standards elebia remote control / Working modes

More information

Ditec DOD Industrial sectional door automations

Ditec DOD Industrial sectional door automations Ditec DOD Industrial sectional door automations (Original instructions) IP1733EN Technical manual www.ditecentrematic.com Index Subject Page 1. General safety precautions 33 2. Declaration of incorporation

More information

UNI EN ISO EN

UNI EN ISO EN Airplus Safeline eneral Upon implementation of the AIRPLUS T series, air-treatment units, PNEUMAX develops a supply and discharge valve, with an electropneumatic control and spring-return, fitted with

More information

Automatic concealed bollards 275 H600 and 275 H800 Control station

Automatic concealed bollards 275 H600 and 275 H800 Control station Automatic concealed bollards 275 H600 and 275 H800 Control station Technical installation manual CE Declaration Warnings for the installer Bollard electrical connection Technical specifications for control

More information

Mod: KLD6-12/35XLAS-N

Mod: KLD6-12/35XLAS-N 12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like

More information

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 The operating instructions...2 2 Intended

More information

Rotary Limit Switches Driver FRS Series

Rotary Limit Switches Driver FRS Series Rotary Limit Switches Driver FRS Series TM Limit Switches Driver FRS Series Main Features Driver rotary limit switch Series FRS is a device which allows you to control the movement of industrial and building

More information

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE by IL n. 366 EDIZ. 28/03/2012 CICLÓN I GB F E P D ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE IRREVERSIBLE ELECTROMECHANICAL PIVOTING ARM ACTUATOR FOR SWING GATES

More information

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

SARGON S - M - L. All rights reserved INSTALLATION MANUAL INSTALLATION MANUAL Our compliments for your excellent choice. SARGON LINE S (300mm) M (400mm) and L (600mm) electro-mechanical gear motor has been produced for reliability and high quality. This Manual

More information

Maximum Weight = 80 kg for 2 doors; Maximum door width = 1100mm (to suit up to maximum 2120mm clear opening) Quick Start. 5 & 4mm Allen keys.

Maximum Weight = 80 kg for 2 doors; Maximum door width = 1100mm (to suit up to maximum 2120mm clear opening) Quick Start. 5 & 4mm Allen keys. EVOLVE 80 SIM KIT FITTING INSTRUCTIONS - NOTICE DE POSE - MONTAGE HANDLEIDING - MONTAGEANLEITUNG ISTRUZIONI DI MONTAGGIO - INSTUCCIONES DE MONTAJE 80kg Maximum Weight = 80 kg for 2 doors; Maximum door

More information

SIZING OF SOLAR GENERATOR

SIZING OF SOLAR GENERATOR MULTI ISLAND is a water pumping system with power from photovoltaic panels. It is designed for use in water wells, irrigation systems, or the power supply network is not available, or when the user wishes

More information

MICRO SWITCH INSTALLATION SHEET

MICRO SWITCH INSTALLATION SHEET MICRO SWITCH INSTALLATION SHEET Micro Switch Cam Rest Position See Vertical or Horizontal Arm Installation Instructions for Micro Switch activation sequence. Micro Switch Cam Adjustment Screw SW 1 Micro

More information

Universal mechanical load limiter HF Series`s. English. ENG: Assembly instructions. Reading this manual for use and maintenance is mandatory.

Universal mechanical load limiter HF Series`s. English. ENG: Assembly instructions. Reading this manual for use and maintenance is mandatory. Universal mechanical load limiter HF Series`s English ENG: Assembly instructions Reading this manual for use and maintenance is mandatory. [1] APS Trako srl Romania PRECEDING INSTRUCTIONS: 1. Before installing

More information

ISTRUCTION MANUAL Italian Movements Italian Movements

ISTRUCTION MANUAL Italian Movements Italian Movements ISTRUCTION MANUAL CONTENTS OF MANUAL 1. General Information page 3 1.1 Introduction to this manual 2 Safety page 3 3. Technical Data page 5 3.1 Table of technical data and CE mark 4 Actuator page 6 4.1

More information

PF2C Rotary Limit Switch. PF2C Rotary Limit Switch

PF2C Rotary Limit Switch. PF2C Rotary Limit Switch The rotary limit switch is used to control the movement of industrial machinery. It operates as an auxiliary controller of electrical motors through a power interface, such as a contactor or PLC. Suitable

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

Modular Flameproof Brakes

Modular Flameproof Brakes Modular Flameproof Brakes New, Easy, Strong 2012 rev 0 INDEX PAG1 PAG2 PAG3 PAG4 PAG5 PAG6 PAG7 PAG8 PAG9-12 About VIS Application example, Main characteristics, Standards Certificates and available protection

More information

POWER SUPPLY UNIT FOR 3 KW MAGNETRON TECHNICAL NOTE

POWER SUPPLY UNIT FOR 3 KW MAGNETRON TECHNICAL NOTE POWER SUPPLY UNIT FOR 3 KW MAGNETRON TECHNICAL NOTE (Issue April 2004) CE Declaration of Conformity Dichiarazione di Conformità CE Manufacturer s Name: Nome del Costruttore: Manufacturer s Address: Indirizzo

More information

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer A company of ThyssenKrupp Elevator ThyssenKrupp Aufzugswerke Operating Manual Oil buffer OPERATING MANUAL Printer s imprint All rights reserved. Copyright by: THYSSENKRUPP AUFZUGSWERKE GMBH P.O. box 23

More information

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

Installation Instructions

Installation Instructions Installation Instructions ELEKTROMAT SE 15.48-25,40 NOT DEFINED Model: 10004112 10006 -en- Status: 21.07.2016 2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom

More information

MANUAL FOR USE AND MAINTENANCE OF THE MACHINE GALAXY

MANUAL FOR USE AND MAINTENANCE OF THE MACHINE GALAXY Page 1 of 19 MANUAL FOR USE AND MAINTENANCE OF THE MACHINE GALAXY It contains: E.E.C. Declaration of Conformity concerning mini-hydraulic cutting machine Page 2 of 19 We Oma System S.r.l. Via delle Scienze,

More information

Installation Instructions: K-Safe-T-Drift

Installation Instructions: K-Safe-T-Drift Micro Switch Installation Sheet Micro Switch Cam Rest Position See Vertical or Horizontal Arm Installation Instructions for Micro Switch activation sequence. Micro Switch Cam Adjustment Screw SW 1 Micro

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.

More information

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC) SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC) TABLE OF CONTENTS 1 EC Declaration of incorporation...1 2 General description...2

More information

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS

ROPE THIMBLE P/N STP-40-SS P/N STP-50-SS PULL WIRE SHOULD BE STRAIGHT AND CLEAR OF OBSTRUCTIONS WIRE SUPPORT P/N STG-200, STG-200-SS 1 P/N: PS-P INSTALLATION & SETTING INSTRUCTIONS YELLOW INDICATION FLAG: P/N STP-F The Indication Flag should be fitted when there is more than one switch used on the conveyor as noted in AS1755-2000 Clause

More information

Support T10552 T10595 T40386

Support T10552 T10595 T40386 T10552 T10595 T40386 en-gb 7 T10552 T10595... 1 General Information Product name: Product type: Product number: Weight: Max. load capacity: Static test coefficient: 3.0 Intended Use: Load holding device

More information

POWER SUPPLY UNIT FOR 2 KW MAGNETRON TECHNICAL NOTE

POWER SUPPLY UNIT FOR 2 KW MAGNETRON TECHNICAL NOTE POWER SUPPLY UNIT FOR 2 KW MAGNETRON TECHNICAL NOTE (Issue October 2004) CE Declaration of Conformity Dichiarazione di Conformità CE Manufacturer s Name: Nome del Costruttore: Manufacturer s Address: Indirizzo

More information

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS VH IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack Our products if installed by qualified personnel capable

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3 Operating Instructions for DORNIER looms Robustness Reliability Quality Productivity Versatility WARNING! - Condensation could form on the Weft Feeder when

More information

FLEXIBLE COUPLINGS RU-STEEL Annex Atex 95

FLEXIBLE COUPLINGS RU-STEEL Annex Atex 95 FLEXIBLE COUPLINGS RU-STEEL Annex Atex 95 Index: 1 Coupling s Choice 2 Assembly and Alignment 3 Simultaneous Alignment Check 4 Coupling s Guard 5 Check Intervals 6 Extraordinary Malfunctions, Causes and

More information

Bowl feeder WV401-1 / Translation of operating and installation instructions

Bowl feeder WV401-1 / Translation of operating and installation instructions Bowl feeder WV401-1 / 402-1 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder WV401-1 Bowl feeder WV402-1 Type 230 V / 50

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

Declaration of Conformity

Declaration of Conformity Declaration of Conformity We, Manufacturer: Spartanics Ltd. 3605 Edison Place Rolling Meadows, Illinois 60008 Phone: 847-394-5700 Fax: 847-394-0409 USA ENGLISH declare under our sole responsibility that

More information

Mod. SC Man09. Manual sliding door USER AND MAINTENANCE MANUAL

Mod. SC Man09. Manual sliding door USER AND MAINTENANCE MANUAL USER AND MAINTENANCE MANUAL Manual sliding door Mod. SC Man09 Frigo Doors by Sevenfrigo srl Via della Tecnica 44 Z.I. Molinaccio 06135 loc. Ponte S. Giovanni - PERUGIA (PG) - ITALY Tel: +39 075 5997648

More information

Ditec LUXO Swing gates automation (Original instruction)

Ditec LUXO Swing gates automation (Original instruction) Ditec LUXO Swing gates automation (Original instruction) IP2128EN Technical manual www.ditecentrematic.com Index Subject Page 1. General safety precautions 21 2. Declaration of incorporation of partly

More information

E N G L I S H HYDRAULIC TRUCK-MOUNTED LIFT. Art. 1120/E Art. 1120/F Art. 1120/G INSTRUCTIONS FOR USE, MAINTENANCE AND SPARE PARTS A 01 03

E N G L I S H HYDRAULIC TRUCK-MOUNTED LIFT. Art. 1120/E Art. 1120/F Art. 1120/G INSTRUCTIONS FOR USE, MAINTENANCE AND SPARE PARTS A 01 03 HYDRAULIC TRUCK-MOUNTED LIFT E N G L I S H Art. 1120/E Art. 1120/F Art. 1120/G INSTRUCTIONS FOR USE, MAINTENANCE AND SPARE PARTS A 01 03 Before use, place on the lift the adhesive labels enclosed with

More information

Bowl Feeder BF10 / BF15 Translation of original operating instruction

Bowl Feeder BF10 / BF15 Translation of original operating instruction Bowl Feeder BF10 / BF15 Translation of original operating instruction Copyright by Afag GmbH This operation instruction applies to: Bowl feeder right 12 Bowl feeder left 12 Type Order number BF10 BF15

More information

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps UNPK04DC Pressure UNPK04DCB Pressure UNPK04DC Vacuum UNPK04DCB Vacuum KNF Neuberger, Inc 2 Black Forest Rd Trenton, NJ

More information