CB33 Pressure Switch CD75 Explosion-Protected Construction Pressure Switch

Size: px
Start display at page:

Download "CB33 Pressure Switch CD75 Explosion-Protected Construction Pressure Switch"

Transcription

1 Cat.No. A6-27 CB Pressure Switch Explosion-Protected Construction Pressure Switch OUTLINE This device is a dead-band adjustable pressure switch designed and manufactured to ensure durability and reliability with an accuracy of.5% max. P. It has excellent vibration-proof characteristics thanks to its double snap action(using Belleville spring) and is therefore ideal in the site for direct control of equipment. FEATURES With the application of a Bellebille spring, this pressure switch demonstrates excellent vibration resistance and durability. (Double Snap Action Mechanism) Adjustable range of dead-band is ~ 2% max. P. Since setting is by multiple rotations (5 rotations / max. P.), accurate setting is possible. Acid-proof coating prevents rusting from salt damage. To keep high accuracy and long life of pressure switch, pressure adjustable range should be to 65% of pressure range. Please pay attention whether wetted parts materials are suitable for gas or liquid to be measured or not. SPECIFICATION Model: CB General process use Explosion-protected construction (Exd II B+H2 T4) Fluid: Gas or liquid Operating condition: CB Under the normal condition, where there is no inflammable gas or liquid which cause the ignition or explosion. Hazardous area The details refer to explanation column of explosion-protected construction. Connection: G/8B(PF), G/2B(PF), Rc/4(PT), Rc/2(PT), /4NPT female, /2NPT( only) For other connections, please contact us. Wetted parts material: Bellows 6Lst.st. Tank socket 6st.st. Please contact us if phosphor bronze bellows (brass body) is required. (CB only) : CB. ~. h.5 ~ 5MPa (. ~ h 5 ~ 5kgf/cm 2 ) -. ~ (- ~ kgf/cm 2 ). ~. h ~ MPa(. ~ h ~ kgf/cm 2 ) -. ~ (- ~ kgf/cm 2 ) Proof-pressure:.5 ~ 2MPa (.5 ~ 2kgf/cm 2 ) (Depending on range) Operating temperature: CB -2 ~ 6g -5 ~ 4g Accuracy: CB.5%max.P..%max.P. Dead band: Adjustable ~ 2%max.P. Switch: Number of contact: One contact (Standard, direct current use) or two contact (Setting dual circuit) Setting system: Internal adjustment type Outlet for electric wire: CB Conduit type PF/2 female Flame-proof packing type Case material finishing: CB Aluminium alloy die casting (ADC2) Blue & Gray Epoxy painted Aluminium alloy casting (AC7A) Blue & Gray Epoxy painted Construction: IP65

2 SPECIFICATION 2 Terminal box:(option)cb only Although the wire used to have to be removed from the terminal plate and the tester terminal pressed against it when measuring contact resistance, with the provision of a check terminal, simply remove the screws on the terminal plate and insert the terminals of the tester. This ensures stability when measuring and eliminates the trouble of removing the wire from the terminal plate. Operation lamp:(option) CB only The on/off state of the pressure switch and the operating state of the microswitch can also be confirmed at a glance. Weight: CB Approx. 2kgs Approx. 5kgs Electric characteristics: Switch Rating Load resistance Inductive load Withstand voltage Insulation resistance Single setting 25V AC 25V AC 25V DC 25V DC A A.5A.25A 6A 4A.5A.A Single setting direct current use Single setting dual circuits 25V AC 25V AC 25V DC 25V DC 25V AC 25V AC 25V DC 25V DC A A A A A A.5A.25A 6A.5A 6A.5A 6A 4A.5A.A 2V AC Beween terminal and case minute 5V DC MΩ over Beween terminal and case Inductive load :Power factor.4 over(ac) Time-constant 7ms or less(dc) One contact direct current use: Direct current rating is bigger than standard. and dead band Proof-pressure: MPa(kgf/cm 2 ) (Adjustable range) Dead band MPa(kgf/cm 2 ) (Adjustable range) Proof-pressure MPa(kgf/cm 2 ) -. ~ (-~ ).~.2 (.~.2).5 (.5).~. (.~ ).~.2 (.~.2).5 (.5).2~.2 (.2~ 2).6~.4 (.6~.4). ().~. (.~ ).9~.6 (.9~.6).45 (4.5).4~.4 (.4~ 4).2~.8 (.2~.8).6 (6).6~.6 (.6~ 6).8~.2 (.8~.2).9 (9). ~ (~ ). ~.2 (. ~ 2).5 (5).5~.5 (.5~ 5).45~. (.45~ ) 2.25 (22.5).2 ~2 (2~ 2).6 ~.4 (.6 ~ 4) (). ~ (~ ).9 ~.6 (.9 ~ 6) 4.5 (45).5 ~5 (5~ 5).5 ~ (.5 ~ ) 7.5 (75).7 ~7 (7~ 7).2 ~.4 (2. ~ 4).5 (5) ~ (~). ~2 ( ~ 2) 5 (5).5 ~5 (5~5) CB only.75 ~ (7.5 ~ ) 2 (2)

3 DIMENSIONS CB (.8) DIA. 8-6 DIA. Mounting hole 96 For range.mpa 8 (kgf/cm 2 ) or less NAGANO KEIKI 5 69 (2.5) Bracket For range.mpa (kgf/cm 2 ) or less PF/2 5 6 G/2B(PF).4,.6,,.5,2,MPa (4,6,,5,2, kgf/cm 2 ) 2 24X27.7 Hex. 24x27.7 G/2B (PF) 82 DIA ,.MPa (2,kgf/cm 2 ) 24 Flats G/2B (PF) 2 5,7,,5MPa (5,7,,5 kgf/cm 2 ) G/2B (PF) 9 DIA. 2 6 G/2B (PF) 9 DIA MPa (-kgf/cm 2 ).MPa (kgf/cm 2 ) Dimensions marked with are also applied to.mpa (kgf/cm 2 ) Option Neon lamp or LED

4 DIMENSIONS 2.4,.6,,.5,2,MPa (4,6,,5,2,kgf/cm 2 ) Panel mounting 4 4 DIA. 7 Terminal box (2) (9) 48 (274.5) 4 DIA Flame-proof packing type () DIA. G/2B(PF) 54 5,7,MPa (5,7,kgf/cm 2 ) -.MPa (-kgf/cm 2 ) (9) (46) 2 G/2B (PF) 2 9 DIA. G/2B (PF) 42.MPa (kgf/cm 2 ) Dimensions marked with are also applied to.mpa (kgf/cm 2 ) () 2 9 DIA. G/2B(PF).,.2,.MPa (,2,kgf/cm 2 ) 4 2B pipe mounting (62) (2) 7 (2.5) (48) 2 DIA. (2) (6) 27 G/2B (PF) 2B pipe.75 M8 (98)

5 EXPLOSION-PROTECTED CONSTRUCTION Type approval for explosion-proof: () It acquires a technical standard adjusted in international standard IEC by the ministry of Labor notification and the national authorization on the basis of new explosion proof guide. Type name Type approval number No.C24 Explosion-protected construction: Explosion protected-construction is a totally enclosed construction such that even if the explosive gas explodes inside the container, the container withstands the force of the explosion and there is no danger of ignition of external explosive gases. As for our pressure switch produced based on this policy, use can have combustible gases or steam of combustibility liquid in pressure measurement at a place with existing fear in a factory, other business office. Exd II+H2 T4 : Ex d II B+H2 T4 Temperature class II B+H2:Hydrogen gas is also contains in II B group A sign of explosion proof construction Group classification A kind of explosion proof electrical instrument and apparatus is classed in group I and group II by a place to be used. belongs to group II, and comes under machinery using it in a factory except hazardous location of the mine or hazardous location of business office. Applicable group and classification of gas or steam. Classification of gas or steam Applicable group A II A II B IIC B C IIB IIC IIC Ignition point of gas or steam which T4 can apply. Ignition point of gas or steam Higher than 45g Higher than g Higher than 2g Higher than 5g Applicable temperature class T T2 T T4 T5 T6 T2 T T4 T5 T6 T T4 T5 T6 T4 T5 T6 Higher than g Higher than 85g T5 T6 T6 Example of applicable gas or steam. Temperature class T T2 T T4 T5 T6 Group Acetone Ethanol Hexane Acetaldehyde Ammonia -butanol Carbon monoxide Butane Ethane Acetic acid IIA Ethyl acetate Toluene Propane Benzene Methanol Methane IIB IIC Hydrogen Ethylene Ethylenoxide Acetylene Ethylmethyl Ether Carbon bisulfide Nitric acid ethyl

6 WIRING CB SW SW INC. DEC. Terminal division a : b : c : a c b Terminal INC. DEC. COM Ṅ.C. Terminal 2SW (D.P.D.T.) INC. DEC. Terminal division a.2a : b.2b : c.2c : a c b 2a 2c 2b Terminal 2SW(D.P.D.T.) INC. DEC Terminal OUTLET FOR ELECTRIC WIRE Conduit Connection Packing inner DIA.(d) Applicable cable Out DIA. Protecting tube Connection PF/2 8 DIA.~2 DIA. mm step 7. DIA.~2. DIA..5mm step PF/2 PF/4 DIA.~6 DIA. mm step 2. DIA.~6. DIA..5mm step PF/4 Terminal box PF 7 DIA.~2 DIA. mm step 6. DIA.~2. DIA..5mm step PF Washer Ring packing ME set screw Cable gland Cable clamp Cable protecting tube connection Applicable cable out DIA.

7 Type No. constitution Please specify Type No.,each specification and range when ordering. Note:For this Model,there is no applicable item for the figures X,but please specify X when ordering. Pressure switch C B Type No. Selection spec. Additional spec. (Option) Other additional spec. Switch Single setting S.P.D.T. Single setting direct current use S.P.D.T. 2 Single setting dual circuit D.P.D.T. 2 Connection X G/8B G/2B Rc /4 Rc /2 /4NPT female Please specify your requirement For nuclear power plant, bracket, case finishing For range.mpa or less, bracket is equipped as standard. Operation lamp 5 With LED(24V DC) With neon lamp(v AC) With neon lamp(22v AC) 9 Terminal box W/Check terminal 8 Treatment Wetted parts material Socket:6st.st.,Bellows:6Lst.st. 2 Use no oil Use no water Use no oil & water 7 Outlet for electric wire 4 (MPa) (When ordering, please specify pressure range & unit.) -. ~ 2. ~.,.2 ~.2,. ~..4 ~.4,.6 ~.6,. ~.5 ~.5,.2 ~ 2,. ~ 4.5 ~ 5,.7 ~ 7, ~,.5 ~ 5 2 Conduit PF/2 female 6 Switch Standard Standard + gold plated 5 Document 5 Type of contact H:Upper limit type with one contact 2 L:Lower limit type with one contact 4 2H:Upper limit type with two contact 5 2L:Lower limit type with two contact Please specify your requirement Drawing one sheet, Instruction manual, Inspection procedure, Mill sheet, Test report Appoint old model model in case of hope extra.

8 I Type No. constitution Please specify Type No.,each specification and range when ordering. Note:For this Model,there is no applicable item for the figures X,but please specify X when ordering. Pressure switch Type No. Selection spec. Additional spec.(option) Mounting type Panel mounting, Flame-proof packing type 7 2B pipe mounting, Flame-proof packing type 2 Connection M X G/8B G/2B Rc /4 Rc /2 /2NPT /4NPT female 8 Treatment 2 9 Other additional spec. Please specify your requirement Case finishing Use no oil Use no water Use no oil & water Switch 2 4 (MPa) (When ordering, please specify pressure range & unit.) -. ~ Single setting (S.P.D.T.) Single setting direct current use (S.P.D.T.) Single setting dual circuit (D.P.D.T.) 2. ~,.2 ~.2,. ~..4 ~.4,.6 ~.6,. ~,.5 ~.5,.2 ~ 2,. ~ 4.5 ~ 5,.7 ~ 7, ~ 7 Outlet for electric wire Packing inner DIA.mm (PF/2 female) 4 Packing inner DIA.2mm (PF/2 female) 6 Packing inner DIA.4mm (PF/4 female) 8 Packing inner DIA.6mm (PF/4 female) A Packing inner DIA.7mm (PF female) Since the inside diameter of the packing can be manufactured in -mm step, please consult us for other cases. 5 Document 5 Type of contact H :Upper limit type with one contact 2 L :Lower limit type with one contact 4 2H:Upper limit type with two contact 5 2L:Lower limit type with two contact 6 Switch Standard Standard + gold plated Please specify your requirement Drawing one sheet, Instruction manual, Inspection procedure, Mill sheet, Test report The contents in the catalogue are subject to change without notice. Q u a ISO 9 NA GA NO l i t y S KE t y s I K e m UEDA FACTORY (JQA-794) MARUKO FACTORY (JQA-789) HEAD OFFICE & OVERSEAS : --4, HIGASHIMAGOME OHTA-KU, TOKYO, JAPAN. TELEPHONE : (776) 528 SALES DEPT FAX TELEX : (776) 5447 : NKSTKY J OVERSEAS PLANTS OR AFFILIATES: U.S.A., KOREA, GERMANY OVERSEAS SALES NETWORK: AUSTRALIA, HONG KONG, INDONESIA, KOREA, MALAYSIA, PHILIPPINES, SINGAPORE, TAIWAN, THAILAND, U.S.A. PRINTED IN JAPAN '97.2.A

Fans for ATEX EXPLOSIVE ATMOSPHERES

Fans for ATEX EXPLOSIVE ATMOSPHERES Fans for ATEX EXPLOSIVE ATMOSPHERES An ATEX area is a mixture of air and inflammable gas, the vapour of an inflammable liquid, a fog of combustible liquid or combustible powder, which, if they catch fire,

More information

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller

More information

BFG range BFGC range BFN range

BFG range BFGC range BFN range BFG range BFGC range BFN range LOW AND MEDIUM VOLTAGE MOTORS FOR HAZARDOUS AREAS EEx d EEx de EEx na - Flameproof Motors - Flameproof Motors With Increased Safety Terminal Box - Non Sparking Motors TABLE

More information

BFG range BFGC range BFN range

BFG range BFGC range BFN range BFG range BFGC range BFN range LOW AND MEDIUM VOLTAGE FOR HAZARDOUS AREAS EEx d EEx de EEx na - Flameproof Motors - Flameproof Motors With Increased Safety Terminal Box - Non Sparking Motors 1. MARKING

More information

Explosion Proof (Flameproof) Solenoid Operated Directional Valves. (Old) DSG-01-***-*X*-50. Notice of Model Change

Explosion Proof (Flameproof) Solenoid Operated Directional Valves. (Old) DSG-01-***-*X*-50. Notice of Model Change NO. 15 05 05E March 2015 Public Relations Group Sales Planning Section Sales Planning Department Hamamatsucho Seiwa Bdg., 4-8, Shibadaimon 1-chome, Minato-ku, Tokyo 105-0012, Japan Tel: +81-3-3432-2113

More information

EXPLOSION-PROOF MOTORS SINGLE PHASE

EXPLOSION-PROOF MOTORS SINGLE PHASE AC Motors MOTORS SINGLE PHASE Underwriters Laboratories and Canadian Standards Association Listed These explosion proof motors are designed and approved for application in hazardous environments having

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

Pressure Switches Type Z

Pressure Switches Type Z Pressure Switches Type The actual results prove of reliability. A Total Supplier of Pressure Switches Taihei Boeki Co., Ltd. QEC25000ISO 9001:2015 Design and manufacturing of pressure switch High-performance

More information

Compact temperature switch Model TCS

Compact temperature switch Model TCS Mechatronic temperature measurement Compact temperature switch Model TCS WIKA data sheet TV 31.64 Process Compact Series Applications Temperature monitoring and control of processes Safety-critical applications

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog 3-4 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog -2 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb Article

More information

Compact pressure switch Model PCS

Compact pressure switch Model PCS Mechatronic pressure measurement Compact pressure switch Model PCS WIKA data sheet PV 33.30 for further approvals see page 4 Process Compact Series Applications Pressure monitoring and control of processes

More information

Pressure switch FF 4 Approval acc. to ATEX EN For mining and chemistry

Pressure switch FF 4 Approval acc. to ATEX EN For mining and chemistry Approval acc. to ATEX EN 679 Description n... 3 bar with perbunan diaphragm. n 6... 5 bar with plastic plunger and throttle. n Throttle must be removed when using viscous media. 151 mm 7 13 mm a 1 mm,5

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

Mini pressure switch Stainless steel switch enclosure Model PXS

Mini pressure switch Stainless steel switch enclosure Model PXS Mechatronic pressure measurement Mini pressure switch Stainless steel switch enclosure Model PXS WIKA data sheet PV 34.36 Process Mini Series Applications Pressure monitoring and control of processes Safety-critical

More information

Unused flameproof threads for cable glands have to be closed with certified plugs.

Unused flameproof threads for cable glands have to be closed with certified plugs. E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.

More information

Be prepared with Lutz. Safety is our concern

Be prepared with Lutz. Safety is our concern Be prepared with Lutz Safety is our concern L u t z P u m p S e t s L u t z P u m p S e t s Lutz Pump Sets A quick solution for many applications 2 Already pre-assembled Example: Pump set consisting of:

More information

Compact differential pressure switch Models DC, DCC

Compact differential pressure switch Models DC, DCC Mechatronic pressure measurement Compact differential pressure switch Models DC, DCC WIKA data sheet PV 35.40 Process Compact Series Applications Differential pressure monitoring and control of processes

More information

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA Mechatronic pressure measurement Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA WIKA data sheet PV 34.38 Applications Pressure monitoring and control of processes

More information

Mini temperature switch Stainless steel switch enclosure Model TXS

Mini temperature switch Stainless steel switch enclosure Model TXS Mechatronic temperature measurement Mini temperature switch Stainless steel switch enclosure Model TXS WIKA data sheet TV 31.70 Process Mini Series Applications Temperature monitoring and control of processes

More information

Control pressure switch series FF 4

Control pressure switch series FF 4 .11 up to 5, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale Applications Air compressors, water pumps, booster pumps, firefighting equipment, oil supply equipment.

More information

ATEX LABELLING FOR MOTORS AND GEAR UNITS

ATEX LABELLING FOR MOTORS AND GEAR UNITS ATEX LABELLING FOR MOTORS AND GEAR UNITS EN ATEX INFORMATION GAS AND DUST COMPLETE DRIVE SOLUTIONS FROM A SINGLE SOURCE RELIABLE n Reliable products n Coordinated components n NORD's own development and

More information

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS AP1000-2000 Airpower positioners are a robust range of rotary or linear valve positioners in AP1000 electro-pneumatic (4-20mA), AP1200 pneumatic (3-15 psi) or AP2000 programmable smart type. Designed to

More information

Magnetic Switches for WEKA Visual Level Indicators Australian Version

Magnetic Switches for WEKA Visual Level Indicators Australian Version Magnetic Switches for WEKA Visual Level Indicators Australian Version -1- Overview Overview and Selection Guide Installation Information for electrical Reed switches Page 2 3 Type old version Function

More information

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2 Series 0 D Pressure switches for all-fluid technique Port sizes and Microswitch with gold-plated contacts (silver plated for outdoor variants) Plug-in connection to DIN 4650 Technical Data Fluid: Neutral

More information

Hazardous Duty Applications

Hazardous Duty Applications Hazardous Location Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Plugs, Receptacles and Interlocks Hazardous Duty Applications Russellstoll Hazardous Duty Plugs, Receptacles and Interlocks

More information

VL (AZ8) Limit Switches

VL (AZ8) Limit Switches COMPACT SIZE LIMIT SWITCHES VL (AZ8) Limit Switches A compact and accurate vertical limit switch. Switches with indicator lamp available for convenient maintenance; either a neon AC powered lamp or an

More information

VL (AZ8) Limit Switches

VL (AZ8) Limit Switches COMPACT SIZE LIMIT SWITCHES Limit Switches A compact and accurate vertical limit switch. Type with a lamp which makes maintenance convenient; either a neon AC powered lamp or an LED DC powered lamp. With

More information

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42) Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of

More information

Pressure switch FF up to 250 bar, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale

Pressure switch FF up to 250 bar, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale Microlectra bv. www.microlectra.nl info@microlectra.nl Pressure switch FF.11 up to 25, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale 151 mm 75,5 mm a 1 mm,5

More information

Pump kits. We deliver values.

Pump kits. We deliver values. Pump kits We deliver values. Table of contents FLUX Pump Kits for: Acids and alkalis 4 5 Concentrated acids and AdBlue 6 Petroleum products 7 Flammable liquids 8 Universal applications 9 99,98 % barrel

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

Filtration efficiency: 99% or more HEPO2element

Filtration efficiency: 99% or more HEPO2element High Precision Filter for Liquids Series Filtration efficiency: 99% or more HEPO2element Filtration accuracy: 2, 4, 6 or 13 µm (Filtration efficiency 99%) Membrane element Filtration accuracy: 0.2 or 0.4

More information

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons   Gases C-C Hydrocarbons C-C Paraffins. Methane. Carbon Dioxide. Ethylene. Ethane. Acetylene. Methane (0.9%). Ethane (0.09%). Propane (0.099%). Isobutane (0.09%). Butane (0.09%). n-pentane (0.00%) Column: ft x

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such

More information

VACUUM A RESOURCE FOR EVERYONE

VACUUM A RESOURCE FOR EVERYONE Vacuum grippers VACUUM PRODUCTS INNOVATORS IN VACUUM TECHNOLOGY CATALOG VERSION 5.0 VACUUM A RESOURCE FOR EVERYONE www.piab.com Accessories Suction cups Vacuum pumps PVA VACUUM SWITCHES, INDUCTIVE UNIVERSAL

More information

Flame arresters/vents

Flame arresters/vents Flame arresters/vents Product information serving the gas industry worldwide Introduction RMG-GASELAN Regel- und Messtechnik GmbH is a company based in Germany. We produce devices and safety systems recommended

More information

Valve Position Monitors

Valve Position Monitors CONTROLS Valve Position Monitors EX Series for Hazardous Locations APL Series NEMA 4, 4X CONTROLS Triac APL Series Limit Switches The Triac APL Series Limit Switches feature high quality, easy to use multiple

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

Series PMB-D PRC-A PMB-C

Series PMB-D PRC-A PMB-C Low Vacuum Pump Mechanical Booster Pump PMB / PRC Series By using mechanical booster pumps together with backing pumps such as dry vacuum pumps and oil rotary pumps, it is possible to increase pumping

More information

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A CONTENTS Page 5 555 09 5 555 29 5 555 59 5 555 9 1. General characteristics...1 2. Use...1 3. Range/Equivalence table...2 4. Dimensions..............................3 5. Technical characteristics...5 6.

More information

HD and HDL Single-Stage Non-Lube Gas Compressors

HD and HDL Single-Stage Non-Lube Gas Compressors COMPRESSORS CB-324 2013/05 Ethylene Ethylene Oxide HCFC s Helium n-heptane n-hexane Hydrogen Hydrogen Chloride Hydrogen Sulfide Isobutane Isobutene Isobutylene Isopentane Methane Methanol Methyl Acetylene

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion EX-PROTECTION ADVANTAGES Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all zones The

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

International approvals.

International approvals. E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42) Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable

More information

PFA Lined Ball Valve:Model PF2 PFA. Lined Check Valve: Model PSC20. CATALOGUE No.ZP05 NIPPON VALQUA INDUSTRIES, LTD. NIPPON VALQUA INDUSTRIES, LTD.

PFA Lined Ball Valve:Model PF2 PFA. Lined Check Valve: Model PSC20. CATALOGUE No.ZP05 NIPPON VALQUA INDUSTRIES, LTD. NIPPON VALQUA INDUSTRIES, LTD. Revised April 2017 CATALOGUE No.ZP05 PFA Lined Check Valve: Model PSC20 Spring Type "VALQUA" is a compounded word coming from VALUE and QUALITY which is the symbol and motto of the company. The above trade

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

ARM1000/2000. Standard Specifications

ARM1000/2000. Standard Specifications .5- Regulator Manifold ARM000/000 4 connection methods Standard Specifications Fluid Proof pressure Max. operating pressure Set pressure range Ambient and fluid temperature Cracking pressure (Valve) Construction

More information

Differential pressure gauges with Bourdon tube

Differential pressure gauges with Bourdon tube Differential pressure gauges with Bourdon tube Nominal dia. and with movement of Brass or stainless steel measuring monitoring analysing Description These pressure gauges are suitable for measuring of

More information

Pressure Instrument Testing Equipment

Pressure Instrument Testing Equipment Pressure Instrument Testing Equipment BULLETIN TE-1 A Halliburton Company A Durable, Portable Primary Standard Model 1305D Deadweight Tester The Ashcroft 1305D Deadweight Tester is an affordable, portable

More information

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key HSB Series Full Size Interlock Switch HSB features: Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available

More information

7 NK 72 en Issue 12/99 LIMIT SWITCHES. Series NK700 INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

7 NK 72 en Issue 12/99 LIMIT SWITCHES. Series NK700 INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS 7 NK 72 en Issue 12/99 LIMIT SWITCHES Series NK700 INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS 2 Table of Contents 1 INTRODUCTION..................... 3 1.1 General description......................

More information

Installation, Operation & Maintenance of the In-Line Flame Arrestor Model L76L-UF

Installation, Operation & Maintenance of the In-Line Flame Arrestor Model L76L-UF Installation, Operation & Maintenance of the In-Line Flame Arrestor Model L76L-UF IOM-L76L-UF Ref. I.D.: 102171 TABLE OF CONTENTS INTRODUCTION 3 INSTALLATION 3 DESIGN AND FUNCTION 7 MAINTENANCE 7 PRODUCT

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion Ex-protection Explosion protection Valves for fluid technology for use in explosion hazard areas Explosion protection for gas, dust and mining Flameproof enclosures and intrinsic safety Solutions for all

More information

Filtration efficiency: 99% or more

Filtration efficiency: 99% or more High Precision Filter for Liquids Series Filtration efficiency: 99% or more HEPO2element Filtration accuracy: 2, 4, 6 or 13 µm (Filtration efficiency 99%) Membrane element Filtration accuracy: 0.2 or 0.4

More information

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy 2 3 4 5 6 7 8 9 Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy Turbine oil P-32 Turbine oil 32 Turbine 32 Turbine oil 32 R turbine oil 32 Turbine oil 32

More information

Precision. Consistently.

Precision. Consistently. Precision. Consistently. CONTENTS INDEX PRODUCT RANGE... 4 Standards & References Rating Plate Ambient Temperature... 5 Tolerance on Performance Parameters & Dimensions... 6 TERMINAL BOX DATA Effect of

More information

Pump Kits. More than just pumps

Pump Kits. More than just pumps Pump Kits More than just pumps Table of Contents FLUX Pump Kits for: Acids and Alkalis 4 5 Concentrated Acids and AdBlue 6 Petroleum Products 7 Flammable Liquids 8 Universal Applications 9 99.98 % Drum

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Information. Mechanical. Electrical. Chemical. Conversions & Calculations

Information. Mechanical. Electrical. Chemical. Conversions & Calculations i Information Installation Monitoring Repair As part of our fluidity.nonstop concept, AxFlow has become one of the leading UK providers of pump care services. We have Pump Service Centres spread across

More information

Petroleum industries are dealing with different hazardous materials starting from storing, processing and distributing the petroleum products These he

Petroleum industries are dealing with different hazardous materials starting from storing, processing and distributing the petroleum products These he FIRE SAFETY OF PETROLEUM INDUSTRIES By- Debapriya Biswas Additional Director General West Bengal Fire & Emergency Services Petroleum industries are dealing with different hazardous materials starting from

More information

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON MOST COST EFFECTIVE FLOW MEASUREMENT O-1000 Series ORIFLOMETER GENERAL O-1000 series ORIFLO METER is a flow meter consisting of an orifice plate and a metal tube variable area flow meter. Since the flow

More information

Azbil Corporation All Rights Reserved.

Azbil Corporation All Rights Reserved. No. CP-SP-1318E Operating Manual for 1LX7 _-J with Increased-Safety Conduit and 1LX7 _-R with Increased-Safety Packing Gas/ Vapour Explosion-Proof Limit Switches for Outdoor Applications, Compliant with

More information

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded

More information

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP High-pressure for gas, air, flue gases and combustion products HP /2 HP 5.04 Printed in Germany Rösler Druck Edition 06.04 Nr. 241 654 1 6 Technical description The pressure is an adjustable pressure for

More information

http://www.kosmek.co.jp FOR PRESS MACHINES Company Profile K OS ME K LTD. H ea d O f f i ce Company Name KOS ME K L T D. Established Ma y 1 9 8 6 Capital 99,000,000 Sales 6 0 b i l l i o

More information

EL Series Explosion Proof Linear Actuators

EL Series Explosion Proof Linear Actuators EL Series Explosion Proof Linear Actuators The EL Series linear actuators offer users all of the advantages of Exlar s patented inverted roller screw actuator designs in a Class I, div 1, Groups B, C or

More information

Small on price, big on boot

Small on price, big on boot 018 VOLUME 1 FEATURES KEY Toe Cap High Heat Non Conductive Female Male Leather Chemical Body International Organization for Standardisation Body PU - Polyurethane RECOMMENDED INDUSTRY USE* General Smelting/

More information

TEMPERATURE AND PRESSURE SWITCHES

TEMPERATURE AND PRESSURE SWITCHES TEMPERATURE AND PRESSURE SWITCHES APPLICATIONS : HYDRAULIC, PNEUMATIC AND ENGINE LM Instrumentation 2 rue Junon 44 470 CARQUEFOU - FRANCE Tél. : +33 2 40 18 51 00 Fax : +33 2 40 18 51 10 lmi@lminstrumentation.fr

More information

by Jim Phillips, P. E.

by Jim Phillips, P. E. by Jim Phillips, P. E. Baking flour, coal dust and gasoline; what do these things have in common? They are not the ingredients for a strange new cake recipe. Each of these ingredients is the fuel that

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

Sample Installation: Fixed Power Source (Wall) to Remote/Portable Location

Sample Installation: Fixed Power Source (Wall) to Remote/Portable Location Industrial interlocked receptacles are available in 30 through 400. Switched receptacles have mechanical linkages for added safety. Safety features include: Plugs cannot be inserted unless power is safely

More information

Technical Documentation

Technical Documentation Technical Documentation EX09EN ELECTRIC OTORS IN EXPLOSION - PROOF PROTECTION INCREASED SAFETY EExe FLAEPROOF ENCLOSURE EExd Vision We set your ideas in motion. We do not merely manufacture motors, but

More information

TYPICAL APPLICATIONS FOR EL SERIES EXPLOSION-PROOF MOTORS ARE WELL-SUITED TO MANY APPLICATIONS SUCH AS:

TYPICAL APPLICATIONS FOR EL SERIES EXPLOSION-PROOF MOTORS ARE WELL-SUITED TO MANY APPLICATIONS SUCH AS: EL Series Explosion Proof Linear Actuators The EL Series linear actuators offer users all of the advantages of Exlar s patented inverted roller screw actuator designs in a Class I, div 1, Groups B, C or

More information

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP High-pressure switch for gas, air, flue gases and combustion products 5.04 Printed in Germany Edition 02.10 Nr. 241 654 1 6 Technical description The pressure switch is an adjustable pressure switch as

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

Installation Instructions - K-Safe-T-Rip Belt Rip Detector

Installation Instructions - K-Safe-T-Rip Belt Rip Detector Kinder Australia product: Preferred Setup Instructions Note: The correct Belt Rip pick up detachment operation of the Rip Socket, is in a sideways motion to the attachment point. This means once the Socket

More information

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality Full Size Interlock Switch with Locking Solenoid HSC Key features include: Rugged Aluminum Die-cast Housing With the actuator mounted on a movable door, and the switch on a machine, the door can be mechanically

More information

Pressure. Pressure. Mechanical. Press. Switches

Pressure. Pressure. Mechanical. Press. Switches Pressure Pressure Mechanical Press. Switches Contents Mechanical Pressure Switches 4 Introduction 4 Metal Diaphragm 6 Bourdon Tube 7 Compact 8 Diaphragm Seal Piston Summary Mechanical Pressure Switches

More information

2 Fluid Level Management

2 Fluid Level Management 2 Fluid Level Management Introduction.................................... 2-3 REN Oil Level Regulator........................ 2-5 REN Slow Flow Meter.......................... 2-9 Slow Flow Meter Remote

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

Adjustable Dead Band Pressure Switches

Adjustable Dead Band Pressure Switches The adjustable dead band pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points. Function Alarm: Hi Lo Control:

More information

Electric Top-Guided Single-Seated Control Valves

Electric Top-Guided Single-Seated Control Valves No. SS2-AGV200-0300 CV3000 Alphaplus series Electric Top-Guided Single-Seated Control Valves Model AGVB / AGVM OVERVIEW The CV3000 Alphaplus range of top-guided single-seat control valves features a compact

More information

Pressure controls and thermostats, type KPS

Pressure controls and thermostats, type KPS KPS pressure controls are fitted with a 3 mm steel mounting plate. The units should not be allowed to hang from the pressure connection. Pressure connection When fitting or removing pressure lines, the

More information

Metallic Systems TYPE SPTC

Metallic Systems TYPE SPTC CONDUIT 27/01/2009 Technical Data Sheet Page No. 1 Applications Hospitals External Safety Critical Area Fittings IP54 SPB Fittings type A & B Characteristics Very High UV Resistance High Flexibility Medium

More information

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp. Thermostats Description KPS thermostats are temperature-controlled switches. The position of the contacts depends on the temperature of the sensor and the set value. In this series, special attention has

More information

Mini Magnetic Float Type Level Switch

Mini Magnetic Float Type Level Switch 33 Mini Magnetic Float Type Level Switch Hydraulic Equipment. Lubricating Oils. and Coolant Tanks Introduction SFM series float type liquid level Switch made by Seojin Instech is intended for mounting

More information

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2 Hoffman s new ZonEX ATEX-certified enclosures can be used in Zone 1- and Zone 2-rated applications throughout the world. Our NEMA Type 9 enclosures are designed for use in Class II Division 1 and 2 locations

More information

Commonwealth of Massachusetts Approved Product Approval code G

Commonwealth of Massachusetts Approved Product Approval code G AA...A4 Differential Air Pressure Switch Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Model Description &

More information

EZ-View. Flow Meters ISO CERTIFIED 9001

EZ-View. Flow Meters ISO CERTIFIED 9001 EZ-View ISO CERTIFIED 9001 General Design Features OPERATING PRINCIPLE The EZ-View Flow Meter is a variable-area instrument. A precisionmolded, sharp-edged Orifice, located within the Piston Assembly,

More information

Pressure switch, high adjustability of switch differential

Pressure switch, high adjustability of switch differential switch, high adjustability of switch differential For the process industry Model PSM-700, with robust aluminium case WIKA data sheet PV 35.05 Applications Pumps for process applications (e.g. water treatment,

More information

W1000/W3000/W4000/W8000 Series

W1000/W3000/W4000/W8000 Series Filter and W/W/W/ Series New Series of m elements for dust removal, and m elements for tar removal : / to JIS symbol Specifications Descriptions Appearance W W W nic sensor Pressure Working fluid Max.

More information

Local Control Station

Local Control Station Local Control Station As per table given below Ex'd', IIC, IP-66, FLP/WP Local Control Station and Switch MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFRS/104/I/IIC-IEC MFRS/104/IIC-IEC A B C D

More information

SERIES R - MD MOR & GOR

SERIES R - MD MOR & GOR SERIES R - MD MOR & GOR CHARACTERISTICS OPTIONS Aluminium alloy construction Surface protection treatment (anodising, only for ATEX 2 versions) Available in monoblock execution (MOR) and with coupling

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Compact, high-performance limit switch with superior environmental resistance. Broad lineup covers from die casting cases to economical plastic cases.

More information

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP High- switch for gas, air, flue gases and combustion products 5.04 Printed in Germany Edition 01.18 Nr. 241 654 1 6 Technical description The switch is an adjustable switch as per EN 1854 (GW 6000 A4 as

More information