Short form catalogue Fusegear BS and DIN type HRC-fuse links OFFN_, OFAF_H, OFAA_GG. / gg. 4 / gg. OFAA 4gG 800A. OFAA 4gG 800A OFAA. 3gG 400A.

Size: px
Start display at page:

Download "Short form catalogue Fusegear BS and DIN type HRC-fuse links OFFN_, OFAF_H, OFAA_GG. / gg. 4 / gg. OFAA 4gG 800A. OFAA 4gG 800A OFAA. 3gG 400A."

Transcription

1 OFFNF 1 32A 1 / gg OFFNB 1 63A 1 / gg OFFNB 4 4 / gg OFFNC 2 630A 2 / gg OFFNB 4 4 / gg 3gG OFFNB 4 4 / gg 4gG 800A OFFNC 2 630A 2 / gg Short form catalogue Fusegear BS and DIN type HRC-fuse links OFFN_, OFAF_H, _GG 3gG 4gG 800A

2

3 HRC fuses links Contents Fuse range 4 Fuse & switch overview 6 Fuse features 8 OFFNF 1 32A 1 / gg OFFNA 3 63A 3 / gg OFFNB 2 200A 2 / gg BS Type fuses 9 DIN Type fuses Time current curves 14 Cut off currents 16 I2t charecteristics 18 Dimensions 20 OFFNB 1 63A 1 / gg 3 Fusegear 0115 ABB Low Voltage

4 Fuse protection - safe and reliable 2A A BS-type HRC fuse links (bolted-type), OFFN_ 2A A, 415 V OFFNF 1 32A 1 / gg OFFNA 1 32A 1 / gg OFFNA 2 32A 2 / gg OFFNA 3 63A 3 / gg OFFNA 4 125A 4 / gg S04076 OFFNB 1 63A 1 / gg OFFNB 2 200A 2 / gg... BS-size In [A] Tag type F1 A1 A2 A3 A4 B1 B Centred (50 & 63A) Offset Offset Offset Offset Offset Offset (80 & 0A) Offset DIN-type HRC fuse links, gg OFAF_H_, _GG_ 2A A OFAF 00gG 160A OFAF 0gG 160A... DIN-size OFAF 1gG 315A 2gG 315A 3gG OFAF_H_ / ln[a] / 500 V _GG_ / ln[a] / 690 V Fusegear 0115 ABB Low Voltage

5 OFFNB 3 315A 3 / gg OFFNB 4 4 / gg OFFNC 1 1 / gg OFFNC 2 630A 2 / gg OFFNC 3 800A 3 / gg... B3 B4 C1 C2 C Centre Centre Centre Centre Centre 4gG 800A 4a/gG 00A a Fusegear 0115 ABB Low Voltage

6 Fuse and switch overview 2A A For optimum performance ABB recommends using ABB fuses along side ABB OS switch fuses Switch Size [A] AC23/400V [kw] AC23/ [kw] OS20FB_A1_ OS32FB_A2_ OS32GB_ OS0GB_ BS Switch Fuses OS32FB_A1_ - OS63GB_ OS125GB_ OS160GB_ OS200GB_ DIN Switch Fuses - OS40FD_ OS32GD_ OS125GD_ - - OS63GD_ OS160GD_ OFFNA1GG2 OFFNA2GG6 OFFNA2GG6 OFFNA4GG50 BS Fuses OFFNA1GG4 OFFNA2GG OFFNA2GG OFFNA4GG63 OFFNA1GG6 OFFNA2GG16 OFFNA2GG16 OFFNA4GG80 OFFNA1GG OFFNA2GG20 OFFNA2GG20 OFFNA4GG0 S04078 OFFNB 3 315A 3 / gg OFFNA1GG16 OFFNA2GG25 OFFNA2GG25 OFFNA4GG125 OFFNA1GG20 OFFNA2GG32 OFFNA2GG32 OFFNA4GG160 OFFNA1GG25 - OFFNA3GG40 OFFNA4GG200 OFFNA1GG32 - OFFNA3GG OFFNA3GG OFAF000H6 OFAF000H6 OFAF000H32 DIN 500V Fuses - OFAF000H OFAF000H OFAF000H35 - OFAF000H16 OFAF000H16 OFAF000H40 - OFAF000H20 OFAF000H20 OFAF000H50 - OFAF000H25 OFAF000H25 OFAF000H63 S04071 OFAFN 2 500V 2 / gg - OFAF000H32 OFAF000H32 OFAF000H80 - OFAF000H35 OFAF000H35 OFAF000H0 - OFAF000H40 OFAF000H40 OFAF00H OFAF000H50 OFAF00H OFAF000H GG6 000GG6 000GG32 DIN 690V Fuses - 000GG 000GG 000GG35-000GG16 000GG16 000GG40-000GG20 000GG20 000GG50-000GG25 000GG25 000GG63-000GG32 000GG32 00GG80 S01574A 4gG 800A - 000GG35 000GG35 00GG0-000GG40 000GG40 00GG GG GG63-6 Fusegear 0115 ABB Low Voltage

7 OS200B_ OS315B_ OS630B_ OS1250B_ OS250B_ OS400B_ OS800B_ OS200D_ OS400D_ OS630D_ OS1250D_ OS250D_ - OS800D_ - OFFNB1GG50 OFFNB1GG0 OFFNC1GG400 0n request OFFNB1GG63 OFFNB2GG125 OFFNC2GG500 - OFFNB1GG80 OFFNB2GG160 OFFNC2GG630 - OFFNB1GG0 OFFNB2GG200 OFFNC3GG800 - OFFNB2GG125 OFFNB3GG OFFNB2GG160 OFFNB3GG OFFNB2GG200 OFFNB4GG OFFNB3GG OFAF0H32 OFAF0H0 OFAF3H315 OFAF4H630 OFAF0H40 OFAF0H125 OFAF3H355 OFAF4H800 OFAF0H50 OFAF0H160 OFAF3H400 OFAF4H630 OFAF0H63 OFAF0H200 OFAF3H450 OFAF4H630 OFAF0H80 OFAF1H200 OFAF3H500 - OFAF0H0 OFAF1H250 OFAF3H630 - OFAF0H125 OFAF2H315 OFAF3H800 - OFAF0H160 OFAF2H OFAF0H OFAF0H GG50 0GG0-0GG63 0GG125 3GG315 4GG500 0GG80 0GG160 3GG400 4GG630 0GG0 1GG200 3GG425 4GG800 0GG125 1GG250 3GG500 4GG00 0GG160 2GG GG200 2GG GG Fusegear 0115 ABB Low Voltage

8 Fuse protection - safe and reliable Features Total safety for your cables, motors and electronics protection. Wide current ratings for optimal dimensioning of other circuit components. Low let through energy, low cut off characteristics, reduced electro magnetic stress. Energy saving through low power losses. High breaking capacity 80 ka at 415 V (AC). Fault indication on the top of the fuse link for DIN fuses. Conforms to standard IEC OFFNB 4 4 / gg OFFNA 3 63A 3 / gg OFAFN 2 500V 2 / gg OFAFN 3 500V 630A 3 / gg OFFNC 2 630A 2 / gg OFFNB 3 315A 3 / gg OFFNF 1 32A 1 / gg 8 Fusegear 0115 ABB Low Voltage

9 HRC fuse links, BS-type BS-fuse type In [A] Ph [W] Part Number Product Hierarchy Order Code OFFNF 1 32A 1 / gg S04082 OFFNA 1 32A 1 / gg OFFNA 2 OFFNF1 OFFNA1 OFFNA2 32A 2 / gg Tag type: Offset F OFFNF1GG2 1SCA7786R OFFNF1GG4 1SCA7787R OFFNF1GG6 1SCA7788R OFFNF1GG 1SCA7789R OFFNF1GG16 1SCA7790R OFFNF1GG20 1SCA7791R OFFNF1GG25 1SCA7792R OFFNF1GG32 1SCA7793R01 S04076 OFFNA 3 63A 3 / gg OFFNA3 OFFNB1 OFFNB3 OFFNB 1 63A 1 / gg OFFNB 3 315A 3 / gg OFFNA 4 125A 4 / gg OFFNA4 OFFNB2 OFFNB4 OFFNB 2 200A 2 / gg OFFNB 4 4 / gg Tag type: Offset, two holes fixing 20 (except 50A and 63A B1 fuses) A1 A2 A3 A4 B1 B OFFNA1GG2 1SCN833065R OFFNA1GG4 1SCN833066R OFFNA1GG6 1SCN833067R OFFNA1GG 1SCN833068R OFFNA1GG16 1SCN833069R OFFNA1GG20 1SCN833061R OFFNA1GG25 1SCN833070R OFFNA1GG32 1SCN833062R OFFNA2GG6 1SCA7795R OFFNA2GG 1SCA7796R OFFNA2GG16 1SCA7798R OFFNA2GG20 1SCA7827R OFFNA2GG25 1SCA7800R OFFNA2GG32 1SCA7801R OFFNA3GG40 1SCA7803R OFFNA3GG50 1SCA7804R OFFNA3GG63 1SCA7805R OFFNA4GG50 1SCA7806R OFFNA4GG63 1SCA7807R OFFNA4GG80 1SCA7808R OFFNA4GG0 1SCA7809R OFFNA4GG125 1SCA78R OFFNA4GG160 1SCN833063R OFFNA4GG200 1SCN833064R OFFNB1GG50 1SCA7811R OFFNB1GG63 1SCA7812R OFFNB1GG80 1SCA7813R OFFNB1GG0 1SCA7814R OFFNB2GG125 1SCA7816R OFFNB2GG160 1SCA7817R OFFNB2GG200 1SCA7818R01 Tag type: Central, two holes fixing B OFFNB3GG250 1SCA7819R OFFNB3GG315 1SCA7820R OFFNB4GG400 1SCA7822R01 OFFNC 2 630A 2 / gg Tag type: Central, four holes fixing C OFFNC1GG400 1SCA7823R01 C OFFNC2GG500 1SCA7824R OFFNC2GG630 1SCA7825R01 C OFFNC3GG800 1SCA7826R01 OFFNC2 9 Fusegear 0115 ABB Low Voltage

10 HRC fuse links, DIN-type, gg S01350A OFAF000H_ HRC fuse links, gg, universal fuses OFAF_H_, 500 V The type code includes one fuse link. Dual indication. IEC Size In [A] Ph [W] Part Number 000 Product Hierarchy Order Code OFAF000H2 1SCA022627R OFAF000H4 1SCA022627R OFAF000H6 1SCA022627R OFAF000H 1SCA022627R OFAF000H16 1SCA022627R OFAF000H20 1SCA022627R OFAF000H25 1SCA022627R OFAF000H32 1SCA022627R OFAF000H35 1SCA022627R OFAF000H40 1SCA022627R OFAF000H50 1SCA022627R OFAF000H63 1SCA022627R OFAF000H80 1SCA022627R OFAF000H0 1SCA022627R1550 S01351A OFAF 00gG 160A OFAF00H125 1SCA022627R OFAF00H160 1SCA022627R OFAF0H6 1SCA022627R1800 OFAF00H_ 1.5 OFAF0H 1SCA022627R OFAF0H16 1SCA022627R OFAF0H20 1SCA022627R OFAF0H25 1SCA022627R OFAF0H32 1SCA022627R OFAF0H35 1SCA022627R OFAF0H40 1SCA022627R OFAF0H50 1SCA022627R OFAF0H63 1SCA022627R OFAF0H80 1SCA022627R2870 OFAF 0gG 160A OFAF0H0 1SCA022627R OFAF0H125 1SCA022627R OFAF0H160 1SCA022627R OFAF0H200 1SCA022629R5140 OFAF0H_ OFAF0H250 1SCA022629R OFAF1H16 1SCA022627R OFAF1H20 1SCA022627R OFAF1H25 1SCA022627R OFAF1H32 1SCA022627R OFAF1H35 1SCA022627R OFAF1H40 1SCA022627R OFAF1H50 1SCA022627R3840 S01353A OFAF 1gG 315A OFAF1H63 1SCA022627R OFAF1H80 1SCA022627R OFAF1H0 1SCA022627R OFAF1H125 1SCA022627R OFAF1H160 1SCA022627R OFAF1H200 1SCA022627R4490 OFAF1H_ OFAF1H250 1SCA022627R OFAF1H315 1SCA022627R OFAF1H355 1SCA022701R4520 Fusegear 0115 ABB Low Voltage

11 HRC fuse links, DIN-type, gg OFAF2H_ OFAF3H_ OFAF 2gG OFAF 3gG 630A HRC fuse links, gg, universal fuses OFAF_H_, 500 V The type code includes one fuse link. Dual indication on fuse link sizes 2 and 3 up to 630 A. IEC Size In [A] Ph [W] Part Number 2 3 Product Hierarchy Order Code OFAF2H25 1SCA115948R OFAF2H35 1SCA022627R OFAF2H40 1SCA022627R OFAF2H50 1SCA022627R OFAF2H63 1SCA022627R OFAF2H80 1SCA022627R OFAF2H0 1SCA022627R OFAF2H125 1SCA022627R OFAF2H160 1SCA022627R OFAF2H200 1SCA022627R OFAF2H250 1SCA022627R OFAF2H300 1SCA022627R OFAF2H315 1SCA022627R OFAF2H355 1SCA022627R OFAF2H400 1SCA022627R OFAF2H425 1SCA022706R OFAF2H500 1SCA022701R OFAF3H250 1SCA022627R OFAF3H300 1SCA022627R OFAF3H315 1SCA022627R OFAF3H355 1SCA022627R OFAF3H400 1SCA022627R OFAF3H425 1SCA022627R OFAF3H450 1SCA022627R OFAF3H500 1SCA022627R OFAF3H630 1SCA022627R OFAF3H800 1SCA022627R7240 S01362A OFAF 4gG 1250A OFAF4H400 1SCA022627R OFAF4H500 1SCA022627R OFAF4H630 1SCA022627R OFAF4H800 1SCA022627R OFAF4H00 1SCA022627R7750 OFAF4H_ OFAF4H1250 1SCA022627R OFAF4AH500 1SCA022637R OFAF4AH630 1SCA022637R40 4a OFAF4AH800 1SCA022637R OFAF4AH00 1SCA022637R OFAF4AH1250 1SCA022637R4360 OFAF 4a/gG 1250A OFAF4AH_ 11 Fusegear 0115 ABB Low Voltage

12 HRC fuse links, DIN-type, gg 000GG_ 000gG 63A HRC fuse links, gg, universal fuses _GG_, 690V The type code includes one fuse link. Dual indication. IEC Size In [A] Ph [W] Part Number 000 Product Hierarchy Order Code GG2 1SCA022661R GG4 1SCA022661R GG6 1SCA022661R GG 1SCA022661R GG16 1SCA022661R GG20 1SCA022661R GG25 1SCA022661R GG32 1SCA022661R GG35 1SCA022661R GG40 1SCA022661R GG50 1SCA022661R GG63 1SCA022661R GG80 1SCA022700R9440 S01567A 00gG 0A GG0 1SCA022700R GG125 1SCA022724R GG6 1SCA022703R GG 1SCA022703R GG16 1SCA022703R GG_ GG20 1SCA022703R GG25 1SCA022703R GG32 1SCA022703R GG35 1SCA022703R GG40 1SCA022703R GG50 1SCA022703R GG63 1SCA022703R GG80 1SCA022703R GG0 1SCA022703R2340 0gG 160A GG125 1SCA022703R GG160 1SCA022703R GG16 1SCA022703R GG20 1SCA022703R2770 0GG_ GG25 1SCA022703R GG32 1SCA022703R GG35 1SCA022703R GG40 1SCA022703R GG50 1SCA022700R GG63 1SCA022700R GG80 1SCA022700R GG0 1SCA022700R GG125 1SCA022701R0020 S01569A 1gG 200A GG160 1SCA022701R GG200 1SCA022701R GG250 1SCA022701R0370 1GG_ 12 Fusegear 0115 ABB Low Voltage

13 HRC fuse links, DIN-type, gg 2GG_ 2gG 315A HRC fuse links, gg, universal fuses _GG_, 690V The type code includes one fuse link. Dual indication on fuse link sizes 2 and 3. IEC Size In [A] Ph [W] Part Number 2 Product Hierarchy Order Code GG32 1SCA022703R GG35 1SCA022703R GG40 1SCA022703R GG50 1SCA022703R GG63 1SCA022703R GG80 1SCA022703R GG0 1SCA022703R GG125 1SCA022701R GG160 1SCA022701R GG200 1SCA022701R GG250 1SCA022701R GG300 1SCA022703R GG315 1SCA022701R GG355 1SCA022701R GG250 1SCA022703R4120 3GG_ 3gG GG300 1SCA022703R GG315 1SCA022701R GG355 1SCA022701R GG400 1SCA022701R GG425 1SCA022706R GG500 1SCA022701R GG500 1SCA022701R GG630 1SCA022701R GG800 1SCA022701R GG00 1SCA112679R AGG500 1SCA022660R9770 4gG 800A 4a AGG630 1SCA022660R AGG800 1SCA022660R AGG00 1SCA022699R6360 4GG_ 4a/gG 00A 4AGG_ 13 Fusegear 0115 ABB Low Voltage

14 Time current characteristics BS Type Time-current characteristics, OFFN_ fuse links, type gg, 415 V S04059 Pre-arcing time (seconds) Prospective current (amperes) 14 Fusegear 0115 ABB Low Voltage

15 Time current characteristics DIN Type Time-current characteristics, 500 V, gg- fuse links OFAF_H_, sizes /4a Rated current I n /A 2 A 4 A 6 A A 16 A 35 A 125 A 20 A 25 A 32 A 40 A 50 A 63 A 80 A 0 A 200 A 250 A 160 A 224 A 300 A 355 A 315 A 400 A 425 A 450 A 500 A 630 A 800 A 00 A 1250 A 4 3 Pre-arcing time t s /s Prospective current I p /A S07026 Time-current characteristics, 690 V, gg- fuse links _GG_, sizes a Rated current I n /A 2 A 4 A 6 A A 16 A 20 A 25 A 32 A 35 A 40 A 50 A 63 A 80 A 0 A 125 A 160 A 200 A 224 A 250 A 300 A 355 A 315 A 400 A 425 A 450 A 500 A 630 A 800 A 00 A 1250 A 4 3 Pre-arcing time t s /s Prospective current I p /A S Fusegear 0115 ABB Low Voltage

16 Cut off current characteristics BS Type Current limitation, type OFFN_ type gg, 415 V S04060 Cut off current ka (peak) (asymmetrical fault current) Prospective current ka (R.M.S) 16 Fusegear 0115 ABB Low Voltage

17 Cut off current characteristics DIN Type Current limitation, 500 V, gg- fuse links OFAF_H_, sizes /4a 6 Cut-off current (peak) limited by fuse link ic/ka (asymmetrical short-circuit) i s = 2.3 I p 1250 A 800 A 500 A 425 A 355 A 300 A 224 A 160 A 0 A 63 A 40 A 32 A 25 A 20 A 16 A A 6 A 4 A 2 A 00 A 630 A 450 A 400 A 315 A 250 A 200 A 125 A 80 A 50 A 35 A Prospective current Ip (r.m.s.) ka S07030 Current limitation, 690 V, gg- fuse links _GG_, sizes /4a 6 Cut-off current (peak) limited by fuse link ic/ka (asymmetrical short-circuit) I s = 2.3 I p 800 A 500 A 425 A 355 A 300 A 224 A 160 A 0 A 63 A 40 A 32 A 25 A 20 A 16 A A 6 A 4 A 2 A 00 A 630 A 450 A 400 A 315 A 250 A 200 A 125 A 80 A 50 A 35 A Prospective current Ip (r.m.s.) ka S Fusegear 0115 ABB Low Voltage

18 I2t characteristics BS Type I2t -values, OFFN_ fuse links, type gg, 415 V - with prospective current > 80 ka at 415 V S04062 Ampere 2 seconds Fuse rating amperes DIN Type I2t characteristics, 500 V, gg- fuse links OFAF_H_, sizes /4a I 2 t/[a 2 s] A 1 Discrimination B 2 > A 1 + B 1 S07036 B 1 B 2 operating-i 2 t pre-arcing-i 2 t operating-i 2 t pre-arcing-i 2 t S07035 gg, 500 V Fusegear 0115 ABB Low Voltage

19 I2t characteristics DIN Type I2t characteristics, 690 V, gg- fuse links _GG_, sizes I 2 t/[a 2 s] operating-i 2 t pre-arcing-i 2 t A 1 Discrimination B 2 > A 1 + B 1 S07036 B 1 B 2 operating-i 2 t pre-arcing-i 2 t am, 500 V (400V) S Fusegear 0115 ABB Low Voltage

20 Dimensions BS Type OFFN_ fuse links BS-Fuse size A B D E F F BS Fuse size A B D E F G H K S04066 BS-Fuse size A1 & A3 A BS Fuse Size A B D E F G H K A BS Fuse Size A B D E F G H J K A A B1 (80 & 0A) B BS Fuse Size A B D E F G H J B1 (50-63A) B B BS Fuse Size A B D E F G H J L C C C Fusegear 0115 ABB Low Voltage

21 Dimensions DIN Type gg- and am- fuse links OFAF_H_, _GG_ OFA_ 000 OFA_ 00 OFA_ 0 OFA_ 1 OFA_ 2 OFA_ 3 h OFA_ 4a h OFA_ 4 h d e a d e a d e a g OFA_ 000 OFA_ 00 OFA_ 0 OFA_ 2 S07044 f c g OFA_4_ b g OFA_ 3 ( -) OFA_ 1 f c f c b b g b OFA_ 3 ( A) f c Fuse link OFA_000_ OFA_00_ OFA_0_6-160 OFA_0_ OFA_1_16-0 OFA_1_ OFA_2_ OFA_2_ OFA_3_ OFA_3_ OFA_4_ OFA_4A_ IECsize a a b 52,5 59,5 59,5 59,5 64, , c 20,8 29,5 29,5 39,5 29,5 39,5 39, d 49, e 52 52,8 66,8 66,8 70,8 70,8 72,3 72,3 72,3 72, f g h Fusegear 0115 ABB Low Voltage

22 Notes 22 Fusegear 0115 ABB Low Voltage

23

24 Contact us ABB Ltd Tower Court Foleshill Enterprise Park Courtaulds Way Coventry CV6 5NX Tel: Fax: Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB Ltd does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB Ltd. Copyright 2015 ABB Ltd All rights reserved Copyright ABB Ltd 9AKK6354A1407 Power and productivity for a better world TM

Low Voltage Products. HRC Fuse Links OFAFN_ and OFFN_ DIN and BS types, gg 500V 630A OFAFN 3. >80kA. 2 / gg MADE IN ABB

Low Voltage Products. HRC Fuse Links OFAFN_ and OFFN_ DIN and BS types, gg 500V 630A OFAFN 3. >80kA. 2 / gg MADE IN ABB Low Voltage Products HRC Fuse Links OFAFN_ and OFFN_ DIN and BS types, gg OFFNC 2 OFAFN 3 3/gG Fuse protection - safe an 2A...1250 A, 500 V DIN-Type HRC fuse links (blade-type), 2A. DIN-size I n [A] S01350A

More information

Short form catalogue Motor protection and control Manual motor starters

Short form catalogue Motor protection and control Manual motor starters Short form catalogue Motor protection and control Manual motor starters Motor protection and control Index Contents Beneifits 4 Features 5 Overview 6 Manual motor starter MS116 and MS132 8 Manual motor

More information

Short form catalogue Switchgear Enclosed switch disconnectors, switch fuses and transfer switches

Short form catalogue Switchgear Enclosed switch disconnectors, switch fuses and transfer switches Short form catalogue Switchgear Enclosed switch disconnectors, switch fuses and transfer switches MADE IN ABB MADE IN ABB Switchgear Enclosed OT switch disconnectors, OS switch fuses, Manual & automatic

More information

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low

More information

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A DISTRIBUTION SOLUTIONS Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A Efficient protection of voltage transformer circuits Extending the lifetime of installed electrical

More information

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant Product Brochure Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant Introduction General The braking switch serves the purpose of electrical braking a machine in a hydro or pumped

More information

Electrification Products United Kingdom. Buildings & Infrastructure Enhanced energy efficiency & performance

Electrification Products United Kingdom. Buildings & Infrastructure Enhanced energy efficiency & performance Electrification Products United Kingdom Buildings & Infrastructure Enhanced energy efficiency & performance About ABB Let s write the future together ABB is a pioneering technology leader that works closely

More information

Manual motor starters Overview and benefits

Manual motor starters Overview and benefits Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection

More information

Mini contactors B6, BC6 with 3 pole

Mini contactors B6, BC6 with 3 pole Data sheet Mini contactors B6, BC6 with 3 pole Mini contactors from ABB are used for remotely ling motors and other loads wherever space is at a premium. These devices feature hum free coils, shallow depth,

More information

Engineered installation products Solutions for control panel applications

Engineered installation products Solutions for control panel applications Engineered installation products Solutions for control panel applications 2 Engineered installation products Solutions for control panel applications Solutions for control panel applications ABB introduces

More information

Selective main circuit breakers S 750 series Technical Data

Selective main circuit breakers S 750 series Technical Data Selective main circuit breakers S 750 series Technical Data When connecting aluminium conductors ( 4 mm 2 ) ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease.

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

Panorama. Softstarters The complete range

Panorama. Softstarters The complete range Panorama Softstarters The complete range Why does soft starting matter? Controlling industrial electricity. The vast majority of the world s industrial applications are driven by motors. It is estimated

More information

ZX-Family Gas-insulated medium voltage switchgear

ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Minimum overall costs ZX offers maximum economy The compact design of the panels reduces the space required and therefore the size of the station. Freedom

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units ABB MEASUREMENT & ANALYTICS DATA SHEET Series 4234-500 and 4234-600 Katharometer power supply units 2 SE RIE S 4 23 4-500 AN D 4 23 4-600 K ATHAROME TE R POWE R SU PPLY U NITS DS/4 23 4-E N RE V. F Measurement

More information

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection

More information

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage

More information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Short form catalogue Building automation Door communication & access control

Short form catalogue Building automation Door communication & access control Short form catalogue Building automation Door communication & access control Door communication & access control Contents ABB - Welcome overview 4 ABB - Welcome door system 8 ABB - Welcome accessories

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

Surge arrester POLIM-H..SD

Surge arrester POLIM-H..SD Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

BRIDGE-BOY Load limitation electronics with 1 or 3 set points Change from one to two columns Data Sheet DS/BRIDGE-BOY-LCI-EN Rev. A BRIDGE-BOY Load limitation electronics with 1 or 3 set points Electronics with 1 or 3 set points designed, in combination with a load

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

TwinLine The new system of wall-mounting and floor-standing cabinets

TwinLine The new system of wall-mounting and floor-standing cabinets 04 2012 TwinLine The new system of wall-mounting and floor-standing cabinets 04 2012 TwinLine The new system of wall-mounting and floor-standing cabinets 2 2CPC 000 170 L0201 TwinLine The new system of

More information

Surge arrester POLIM-H.. ND

Surge arrester POLIM-H.. ND DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3 IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade

More information

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance 2 Semi-pantograph

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

Surge arrester POLIM-C.. HD

Surge arrester POLIM-C.. HD DATA SHEET Surge arrester POLIM-C.. HD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-A High current impulse I hc (4/10

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

Safety stop buttons Smile, INCA and Compact

Safety stop buttons Smile, INCA and Compact Smile, INCA and are used to safely stop a certain part of a dangerous machine. ABB offers safety stop buttons to suit different needs of connection and communication. Models are available for e.g. external

More information

ZP2.5-PE Spring Terminal Block Ground

ZP2.5-PE Spring Terminal Block Ground Technical Datasheet 1SNK162002D0201.indd 08/06/11 ZP2.5-PE Spring Terminal Block Ground Catalogue Page Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail

More information

Shut-off valves and accessories for pressure measuring instruments

Shut-off valves and accessories for pressure measuring instruments Data Sheet 10/14-4.31-EN Shut-off valves and accessories for pressure measuring instruments Non-replaceable seat and plug Application Shut-off valves for pressure measuring instruments are designed for

More information

Low Voltage Switches. Fusegear Switch fuses OS and OSM

Low Voltage Switches. Fusegear Switch fuses OS and OSM Low Voltage Switches Fusegear Switch fuses OS and OSM Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 DIN-

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector Catalogue March 2015 InLine II - ZLBM/ZHBM Fuse Switch Disconnector 2 1SEC312022B0202 ABB Catalogue Contents Introduction 1 Apparatus 2 Accessories 3 Technical Data 4 Cable terminations and cable shrouds

More information

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices MEDIUM VOLTAGE PRODUCTS The worldʼs fastest switching devices 2 FAULT CURRENT LIMITERS THE WORLDʼ S FASTETST SWITCHING DEVICES The worldʼs fastest switching devices ABBʼs fault current limiters disconnect

More information

ZP2.5-4P Spring Terminal Block Feed-through

ZP2.5-4P Spring Terminal Block Feed-through Technical Datasheet 1SNK162005D0201.indd 08/06/11 ZP2.5-4P Spring Terminal Block Feed-through Catalogue Page Thanks to the ZP2.5-4P, PI-Spring terminal block: Save time and connect directly rigid and flexible

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

Switch fuses OS , OSM

Switch fuses OS , OSM Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 16 Ordering information, manual operation 16 Front operated switch fuses OS 25 Side operated switch fuses

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA The next generation MCB for UL/CSA applications within the proven System pro M compact

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Product Brochure. Grip Tight ball bearings

Product Brochure. Grip Tight ball bearings Product Brochure Grip Tight ball bearings We provide motors, generators and mechanical power transmission products, services and expertise to improve customers, processes and optimize the total cost of

More information

Low Voltage Systems MNS and MNS is PowerCenter

Low Voltage Systems MNS and MNS is PowerCenter Low Voltage Systems MNS and MNS is PowerCenter For our customers, it s all about saving space maximizing functionality for power distribution systems while reducing equipment footprint. ABB has answered

More information

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications 2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up

More information

Safety interlock switch MKey

Safety interlock switch MKey Safety interlock switch MKey MKey are mechanical safety switches used for monitoring doors and hatches. The switch is mounted on the frame and the actuator key on the moving part of the guard. All MKey

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems

ABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems ABB MEASUREMENT & ANALYTICS DATA SHEET 2867 series ph and Redox (ORP) industrial dip electrode systems 2 28 67 SE RIE S P H AN D R EDOX ( ORP) INDU STRIAL DIP E LE C TRODE SYSTE MS DS/28 67-E N RE V. F

More information

US CATALOG. ProLine Panelboard and breakers

US CATALOG. ProLine Panelboard and breakers US CATALOG ProLine Panelboard and breakers 2 PROLINE PANELBOARD AND BREAKERS PROLINE PANELBOARD AND BREAKERS 3 Table of contents 004 006 Description and features 007 008 Guides: and breaker placement 009

More information

Overview Overvoltage protection

Overview Overvoltage protection A P P L I C AT I O N N OT E 1.0 Overview Overvoltage protection The APPLICATION NOTES (AN) are intended to be used in conjunction with the APPLICATION GUIDELINES Overvoltage protection Metal-oxide surge

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies Data sheet Redundancy unit -A-RU Accessory for range power supplies ABB s redundancy units are used to establish true redundancy which increases the availability of electrical systems significantly. 2CDC

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide 1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET 9QGPS5500 Wire rope load cell 2 Measurement made easy Low cost load cell specially designed to measure the tension force on hoisting ropes. CE certified

More information

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket Technical Datasheet 1SNK1659D01 Catalogue Page 1SNK160S01 ZK2.5-SP-P PI-Spring Terminal Blocks Disconnect with plug - with test socket The flexible solution for fitting the component of your choice in

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Voltage limiting device HVL

Voltage limiting device HVL Datasheet Voltage limiting device HVL 120-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 120-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 120-0.3

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Product Brochure. Grip Tight ball bearings

Product Brochure. Grip Tight ball bearings Product Brochure Grip Tight ball bearings We provide motors, generators and mechanical power transmission products, services and expertise to save energy and improve customers, processes over the total

More information

Optimized cost of ownership See all the hidden costs without paying any. ABB Title Lorem Ipsum dolor sit Possible Subtitle

Optimized cost of ownership See all the hidden costs without paying any. ABB Title Lorem Ipsum dolor sit Possible Subtitle Optimized cost of ownership See all the hidden costs without paying any ABB Title Lorem Ipsum dolor sit Possible Subtitle When choosing an electric motor look behind the obvious. Which one is more expensive

More information

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands 1 TEHNIL DT SHEET cable glands SG series Stainless Steel 316L, general purpose cable glands Stainless steel cable glands for general purpose use, OEM, industrial and commercial applications, where a high

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Baldor-Reliance Food Safe Stainless steel NEMA motors

Baldor-Reliance Food Safe Stainless steel NEMA motors FOOD & BEVERAGE Baldor-Reliance Food Safe Stainless steel NEMA motors Food safety first priority of design Reliability in intense cleaning environments Worker safety from installation through operation

More information

Voltage limiting device HVL

Voltage limiting device HVL Datasheet Voltage limiting device HVL 60-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 60-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 60-0.3

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications Data Sheet System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System

More information

EAS822 (Contrac) Power Electronic Unit

EAS822 (Contrac) Power Electronic Unit Contents Data Sheet Rev. A EAS822 (Contrac) Power Electronic Unit For continuous control of Contrac actuators PME120 AN and LME620 AN Microprocessor-controlled power electronic unit with integrated frequency

More information

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications 2CDC021031S0011 2CDC021033S0011 The miniature circuit breaker S 200 M UC extends the established ABB System pro M compact

More information

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011 Technical Data 2CDC508163D0201 ABB i-bus KNX Device description The Magnetic Contact EnOcean is a surface mounted device for windows or doors. Its purpose is to recognize the opening or closing of windows

More information

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring ABB is a leader in power and automation technologies that enable utility and industry customers to

More information

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic Technical Information TI/266LT-EN Rev.A 2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic Measurement Made Easy Engineered solutions for all applications Improved

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication

More information

Surge arrester POLIM-H..N

Surge arrester POLIM-H..N Data sheet Surge arrester POLIMH..N Technical data Arrester class SH, Station High Line discharge class (LD) 4 Nominal discharge current I n (8/20 µs) 20 ka peak Repetitive charge transfer rating Q rs

More information

Bussmann series NH catalogue. Leadership in circuit protection

Bussmann series NH catalogue. Leadership in circuit protection Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places

More information

Manual motor starter magnetic only MO325

Manual motor starter magnetic only MO325 Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF

More information

Data Sheet Manual Motor Starters Ex9SN Series

Data Sheet Manual Motor Starters Ex9SN Series Data Sheet Manual Motor Starters Ex9SN Series www.noarkusa.com NOARK Ex9SN Series Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors

More information

Protistor size 70 gr 690VAC (IEC)

Protistor size 70 gr 690VAC (IEC) Protistor size 70 gr SEMICONDUCTOR PROTECTION FUSES SQUARE BODY HIGH-SPEED FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Excellent cycling capability Multiple body sizes and terminals or blades combination

More information

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS10 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK6004D00 Catalogue Page SNK6004S00 ZS0 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 0 mm² (CB certified) 6 AWG in just 8 mm 0. in spacing. SNK6008F004

More information

NEOZED D0 fuse-links gg 400/440VAC

NEOZED D0 fuse-links gg 400/440VAC NEOZED D0 fuse-links gg 400/440VAC LOW VOLTAGE IEC FUSES DIN LV FUSE-LINKS D0 FEATURES & BENEFITS The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non

More information

EMPAC Metal enclosed capacitor bank for wind applications

EMPAC Metal enclosed capacitor bank for wind applications EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks

More information

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS4 Screw Clamp Terminal Blocks Feed-through Technical Datasheet SNK60D0 Catalogue Page SNK60S0 ZS4 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 4 mm² (CB certified) AWG in just. mm 0. in spacing. SNK60F00 SNK0000F0000

More information

ZS50-PE Screw Clamp Terminal Blocks Ground

ZS50-PE Screw Clamp Terminal Blocks Ground Technical Datasheet SNK607D00 Catalogue Page ZS0-PE Screw Clamp Terminal Blocks Ground - Reliable electrical and mechanical contact with the rail that exceeds the requirements of the IEC 60947-7- terminal

More information

SR1 multipurpose enclosures Enclosures for automation and distribution applications

SR1 multipurpose enclosures Enclosures for automation and distribution applications AU TO M AT I O N B OA R D S SR1 multipurpose enclosures Enclosures for automation and distribution applications Complete range of monobloc enclosures for small and mediumsize automation, command and distribution

More information

Insulated crimp terminals For reliable device connection

Insulated crimp terminals For reliable device connection E L EC T R I FI C AT I O N P R O D U C T S, I N S TA L L AT I O N P R O D U C T S Insulated terminals For reliable device connection ELECTRIFICATION PRODUCTS AUSTRALIA AND NEW ZEALAND Spec-Kon Wire terminals

More information

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade Technical Datasheet SNK6D00 Catalogue Page SNK6S00 ZS4-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,

More information

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator Technical Datasheet SNK63D00 Catalogue Page SNK63S00 ZS-SF-R Screw Clamp Terminal Blocks For x 0 and x fuses - with blown fuse indicator - Protect your circuit with x and x0 fuse terminal blocks (fuse

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET 9QGPS5190 Trough hole (annular) heavy capacity load cell 2 Measurement made easy Annular compression load cell. Low profile for high capacity load cells

More information

Control Valve 23 / 24 Single-seat straight-way valve with exchangeable seat ring

Control Valve 23 / 24 Single-seat straight-way valve with exchangeable seat ring Change from one to two columns Data Sheet 10/138.29EN Rev. B Control Valve 23 / 24 Singleseat straightway valve with exchangeable seat ring Size DN 15... DN 100 With pneumatic actuator Verschiedene Gehäusewerkstoffe

More information

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever Technical Datasheet SNK6D0 Catalogue Page ZS-S-R2 Screw Clamp Terminal Blocks Disconnect with lever Simplify the disconnect operations for the disconnect terminal blocks installed next to fuse terminal

More information

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

Brochure. Motor protection and control DRAS enclosed direct-on-line starters Brochure Motor protection and control DRS enclosed direct-on-line starters DRS09 DRS16 enclosed direct-on-line starters 4 to 7.5 kw, protected by thermal overload relays C or DC operated DRS + T16 to

More information