Auto Mains Failure AMF Controller AE10113
|
|
- Lucinda Rodgers
- 6 years ago
- Views:
Transcription
1 Auto Mains Failure AMF Controller AE03
2 Auto Mains Failure DESCRIPTION AMF Controller AE03 is an Automatic Mains Failure controller, which activates the generator during power failure & vice versa. The panel includes mc based controller. The operation is controlled automatically in Auto Mode as well as manually in the Manual Mode. Apart from the activating & deactivating, AMF03 can control the GENSET according to the engine side parameters like Water Temp., Lub oil pressure etc. And alternator side parameter like under voltage, over voltage, under frequency etc. Also it gives us various indications & power measurement. It s having LCD display & user friendly setting parameter. Software also provides inbuilt help menu. SPECIFICATIONS DC supply: 2V DC (Battery supply) Starter output: Signal for relay coil Fuel start/stop output: Signal for relay coil (In CCPL case controls ECU supply) Over all dimensions: (for controller) : 96mm x 96mm x 00mm Approx. weight or controller : 750 gms.
3 Auto Mains Failure FEATURES Microprocessor based design Automatic engine start and stop LCD Display with key pad Solid state fuel stop & crank outputs LED indication for few operations. OPERATION Auto mode: In this mode panel monitors the mains supply (3 phase or single phase). As the incoming mains supply either fail or drops below preset limit i.e. 80V (by default) the generator will be started and load will be transferred to genset, panel will indicate that load is transferred to genset with LED indication. When the AC mains supply returns within limit, the panel will wait for preset time & will transfer the load to mains (indication through LED). The engine will be instructed to stop after preset time. Manual mode: Manual mode is used to start & run the engine with start push button. And it can be stopped by pressing the stop push button. Off mode: Off mode is used to keep the Genset off condition in case of mains fail. Nor AMF controller will transfer the Load on DG. Night mode: Night mode is the special mode in which the Genset will be kept in Off Mode in the specific period of the day. This period is settable. Test mode: Test mode will be active in AUTO / MANUAL mode while mains present. To enter into test mode, press test key, and observe the indications on LCD display.
4 Auto Mains Failure Indication Remote start Charging fail Warning (any warning fault) Shut down fault (any) Mains present DG on Mains CB close DG CB close Indications on LCD display Battery voltage Alternator voltage (for three phases i.e.ph, PH2, PH3) Load current (for three phases i.e.ph, PH2, PH3) Alternator power in kw Alternator power in KVA Alternator KwH Alternator KVAH Power factor (pf) for three phases Alternator supply frequency
5 Auto Mains Failure Key switches F F2 PROG ESC Increment Decrement Enter Left Right ACK. Start Stop Sensor / switches required Lop switch Fuel level switch 25% Charge Fail Water in Fuel Remote Start Remote Stop Apart from this there will be 2 PF contacts that can be programmed as per our requirement. No need to have separate relay card. Every warning fault / shutdown fault will be displayed on the LCD display. Also we can program the parameters as per or requirement with the help of keys provided on the controller. This will b totally user friendly. No need to have separate energy meter, as controller displayed all the required readings.
6 Programmable Parameters No. Parameter Range Start delay 0-59sec Standard if not set 5 sec 2 Mains restore time -59 sec 5 sec 3 Mains under voltage V 90V 4 Mains Over voltage V 250V 5 Warm up time -59 sec 5 sec 6 Cool down time -59 sec 30 sec 7 Generator under voltage V 90V 8 Generator over voltage V 250V 9 CT ratio 0-000A 50:5 0 Generator over load Low frequency 0 - disable or value 0-99Hz 47Hz 2 High frequency 0-99Hz 53Hz 3 Generator fail Alarm 4 Crank Time -20sec 5 sec 5 Charge Fail Level 3-24 volts 8 volt 6 Rest time -59 sec 5 sec 7 Crank attempt -0 attempt 3 attempt 8 LLOP bypass time 0-59 sec 5sec 9 Stop Time 0-59 sec 0 sec
7 Programmable Parameters No. Parameter Range 20 Horn time 0-59 sec 2 Fuel type 22 Faults for programmable relay- pull to stop 2 pull to start -2 faults (table) 23 Faults for programmable relay-2-2 faults (table) 2 24 Faults for programmable relay-3-2 faults (table) 3 25 Faults for programmable relay-4-2 faults (table) 4 26 Single / three phase 27 Low fuel programmable 28 Alarm Time for shut down single phase three phase -Shut down fault 0 only LED indi. -59 sec 29 Alarm 2 Time for shut down -59 sec sec 30 Low Fuel Time for shut down 3-5 min 0 min 3 R.P.M. selection; Frequency = 50 Hz Remote signal Enable/ Disable for Single phase Continuous On time = 500 RPM 2 = 3000 RPM Disable Enable Min Standard if not set 20 sec sec min
8 List of Faults Fault no. Faults Start Fail 2 LLOP 3 Over speed 4 Low Battery 5 Charge fail 6 HWT 7 Low fuel 8 Over load 9 Alarm 0 Alarm 2 Fail to Stop 2 Generator voltage fail
9 TERMINAL DETAILS
10 ARYA ELECTRONICS & CONTROLS Add: S. No. 5, House No. 48/, Ganesh Nagar, Dhayari, Maharashtra, INDIA Office : T ( INDIA ) T ( USA ) info@aryaelectronicsandcontrols.com Web :
OPERATING INSTRUCTION: DGC-6D/6D1I
OPERATING INSTRUCTION: DGC-6D/6D1I GCB Auto Man Stop Fail - PROCOM Pvt Ltd MRM PROCOM Plot No. : 20-21, Industrial Estate, Sector - 59, Phase-II, Faridabad (Haryana) Ph.: 0129-4700400(10 Lines) Email:
More informationCat/DCG-6D1I/07-08/03/Ver 1 Page 2/10
Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10 Index 1.1 Introduction 1.2 Salient Feature of the DGC-6D 1.2.1 Protection & Supervision 1.2.2 Measurement & Display 1.2.3 LED Indications 1.2.4 Timer 1.3 Function
More informationOPERATING INSTRUCTIONS ECON-M
OPERATING INSTRUCTIONS ECON-M INDEX 1.0 Introduction 2.0 Salient features, Protection & Supervision 3.0 Display/ Front Panel 4.0 Switches Description 5.0 LED Annunciations Description 6.0 Lamp Test 7.0
More informationOPERATING INSTRUCTIONS MCP-MT1
OPERATING INSTRUCTIONS MCP-MT1 MRM PROCOM Pvt Ltd ISO-9001-2008 certified organization Plot No. : 20-21, Industrial Estate, Sector - 59, Phase-II, Faridabad (Haryana) Ph.: 0129-4700400(10 Lines) Email:
More informationHGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL
HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,
More informationHGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology
HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951
More informationHGM501 Gen-set Controller USER MANUAL. Smartgen Technology
HGM501 Gen-set Controller USER MANUAL Smartgen Technology Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. OVERVIEW... 4 PERFORMANCE AND CHARACTERISTICS... 4 TECHNICAL DATA... 5 OPERATION... 6 4.1. BUTTON DESCRIPTION...
More informationHGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic
HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic Smartgen Electronic Equipment Co., Ltd No.28 Jinsuo Road Zhengzhou Henan Province P.R.China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951/67992952
More informationUSER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD
HGM400 Series Genset Controller (HGM410/HGM420) USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENTS 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATION... 9 4.1
More informationICON 2 1. FEATURES AND CHARACTEIRICS
ICON 2 1. FEATURES AND CHARACTEIRICS High end Micro-controller(DSP) technology Wide range of auxiliary supply: 7V to 45Vdc. Low power Consumption : 200 ma @ 12 V DC. Alphanumeric 16X4 or 16X2 LCD display
More informationHGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic
HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 FEATURES... 4 3 SPECIFICATION... 4 4 DISPLAY SYMBOL AND OPERATION... 5 5 ALARM... 7 6 PARAMETERS TABLE (ONLY
More informationUSER MANUAL FOR GC500 GENSET CONTROLLER SEDEMAC ABSTRACT
ABSTRACT This manual is intended as an information guide for operating SEDEMAC's GC500 genset controller. USER MANUAL FOR Doc #SED-MAN-GC500-002 Date: 01-Aug-2016 GC500 GENSET CONTROLLER Product Manual
More informationHGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic
HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 4 3. SPECIFICATIONS... 5 4. OPERATION... 6 5. PROTECTION...
More informationHGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...
CONTENT 1. SUMMARY...4 2. PERFORMANCE AND CHARACTERISTICS...4 3. SPECIFICATION...5 4. OPERATION...6 4.1. DISPLAY PANEL...6 4.2. LCD ICON INSTRUCTION...7 4.3. DISPLAY INSTRUCTIONS...7 4.4. DISPLAY DESCRIPTION...8
More informationDSEULTRA DSE6000 Quick Start Guide Document Number
n DSEULTRA DSE6000 Quick Start Guide Document Number 057-102 Author : John Ruddock Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099 Sales
More informationBe-K3 OEM s Manual --
Be-K3 OEM's Manual V200 - July - 010 page 1 Be-K3 OEM s Manual -- Consult Section 17.0 for software upgrades & revisions The information in this document may be subject to change without notice. No part
More information1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.
1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 3. AMMETER/PERCENT OF LOAD: Displays the load on the generator in amps or in percentage.
More informationGENSET CONTROL MODULE A121A / A241A
Technical Data Sheet GENSET CONTROL MODULE A121A / A241A Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 4-alarm light outputs with lamp-test provisions.
More informationGENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).
Technical Data Sheet GENSET CONTROL MODULE A121H / A241H Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 4-alarm light outputs with lamp-test provisions.
More informationHGM6100K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronics
HGM6100K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronics All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing
More informationBe2K-Plus AMF panel control wiring --
Be2K-Plus OEM's Manual V200 - August - 014 page 1 Be2K-Plus AMF panel control wiring -- Consult Section 17.0 for software upgrades & revisions The information in this document may be subject to change
More informationModel H30 Operation Manual
Model H30 Operation Manual Model H30 Version 1.0 August 1, 2007 2 135 West Davenport Street Rhinelander WI 54501 Phone: 866.441.7997 Fax: 866.278.0036 info@houstonst.com www.houstonst.com 3 Table of Contents
More informationHGM1750 Genset Security Module USER MANUAL Smartgen Technology
HGM1750 Genset Security Module USER MANUAL Smartgen Technology CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 5 3. SPECIFICATION... 7 4. OPERATION... 8 5. PROTECTION... 9 6. PARAMETER RANGE
More informationHGM6000K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronic
HGM6000K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 6 4 OPERATION... 6 4.1 KEY FUNCTION... 6
More informationHGM6310D/6320D AUTOMATIC GENERATOR MODULE USER MANUAL
HGM6310D/6320D AUTOMATIC GENERATOR MODULE USER MANUAL SMARTGEN ELECTRONIC CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 6 4 OPERATION... 7 4.1 KEY FUNCTION... 7 4.2 AUTOMATIC
More informationGENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).
Technical Data Sheet GENSET CONTROL MODULE LEVEL 0 A120A Features: One model for both spark ignition and diesel engines. 4-alarm light outputs with automatic lamp-test provision. Overspeed adjustment not
More informationAUTOSTART 705S V1.00 AUTOSTART 710S / 720S / 730S V1.04 Programming Reference and Check Sheets
The Generator Controls Division of Frank W. Murphy AUTOSTART 705S V1.00 AUTOSTART 710S / 720S / 730S V1.04 Programming Reference and Check Sheets MODEX AUTOMATION FRANK W. MURPHY LTD. Church Road Laverstock
More informationHGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL
HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL Smartgen Technology CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATION... 6 4.1 LCD DISPLAY... 6 4.2 KEY
More informationHSC940 Genset Controller CONTENTS 1 OVERVIEW PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION KEY FUNCTIONS...
CONTENTS 1 OVERVIEW... 4 2 PERFORMANCE AND CHARACTERISTICS... 5 3 SPECIFICATION... 7 4 OPERATION... 8 4.1 KEY FUNCTIONS... 8 4.2 INDICATOR LIGHT... 9 4.3 AUTO START/STOP OPERATION... 10 4.4 MANUAL START/STOP
More informationManual and Remote Start Unit with Key Switch, 72x72 DIN Size
Manual and Remote Start Unit with Key Switch, x DI Size FAILED TO ~~~ ~ ~ STOP 0 I Hz./ EAOM - 36 SPEED FAILURE CHARGIG FAIL Features Designed For Generator, Pump & Fire Pump Applications Remote start
More informationDKG-114 MANUAL AND REMOTE START UNIT
DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional
More informationGenerator Controller Manual
Generator Controller Manual Web Site:http://www.monicon.com.tw E-mail:sales@monicon.com.tw 1. Controller Description is low cost but multi-function diesel engine generator controller. It applies with 3
More informationDeep Sea Electronics Plc
Deep Sea Electronics Plc 5520 Operators Manual Author Tony Manton Deep Sea Electronics Plc Highfield House Hunmanby Industrial Estate North Yorkshire YO14 0PH ENGLAND Tel +44 (0) 1723 890099 Fax +44 (0)
More informationTe 803 Electronic Controller. Service, Operation & Technical Information Manual
Te 803 Electronic Controller Service, Operation & Technical Information Manual WARNING! Technical descriptions and data given in this document are accurate, to the best of our knowledge, but can be subject
More informationHGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL
HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951/67992952
More informationDEEP SEA ELECTRONICS PLC
DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >
More informationFlight Systems. Replacement for KASSEC DESCRIPTION
DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc
More informationGENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.
Technical Data Sheet GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 5-alarm light outputs with lamp-test
More informationEAOM-10.2 AUTOMATIC TRANSFER SWITCH & START UNIT FOR DIESEL GENERATORS
AUTOMATIC TRANSFER SWITCH & START UNIT FOR DIESEL GENERATORS Designed for diesel generators Long life membrane front key pad EEPROM internal memory 1 GENERAL INFORMATION EAOM-102 Automatic Transfer Unit
More informationHGM9520 Genset Parallel (With Mains) Unit USER MANUAL. Smartgen Technology
USER MANUAL Smartgen Technology Chinese trademark English trademark Smartgen make your generator smart Smartgen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou city Henan Province P. R. China Tel: +86-371-67988888/67981888
More informationHGM6000K Series Automatic Generator Module USER MANUAL Smartgen Technology
HGM6000K Series Automatic Generator Module USER MANUAL Smartgen Technology Chinese trademark English trademark Smartgen make your generator smart Smartgen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou
More informationDKG-317 MANUAL AND REMOTE START UNIT
Tel: +54-11-4629-600 Fax:+54-11-4627-3500 http://www.cramelectro.com DKG-317 MANUAL AND REMOTE START UNIT FEATURES Manual starting and stopping Engine control Generator protection Built in alarms and warnings
More informationHGM9510 GENSET PARALLEL (WITH GENSET) UNIT USER MANUAL
HGM9510 GENSET PARALLEL (WITH GENSET) UNIT USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd. No.
More informationGENSET CONTROL MODULE
HGM7200/HGM7100 Series AUTOMATIC GENSET CONTROL MODULE User Manual SMARTGEN TECHNOLOGY Smartgen Technology Co., Ltd No.28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888
More informationAdvanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list
OPERATOR'S MANUAL Advanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE710 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44
More informationDeep Sea Electronics Plc
Deep Sea Electronics Plc 5120 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL Author: Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH England Tel: +44 (0) 1723
More informationANALOG CONTROL PANEL
ANALOG CONTROL PANEL 1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 3. Percent of Load: Displays percentage of load on the generator.
More informationPPU Diesel Power 50/60Hz Containerized Generator Set
50Hz at 0.8 Power Factor 380-400V 3-Phase Rated Voltage 60Hz at 0.8 Power Factor 480V 3-Phase Rated Voltage PRIME STANDBY 800kW/1,000kVA 880kW/1,100kVA GENERATOR SET PERFORMANCE Application A factory designed
More informationAutomatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list
OPERATOR'S MANUAL Automatic Genset Controller, AGC-4 Display readings Push-button functions handling Log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com
More informationMKN-DSP SERIES - THREE PHASE
Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /
More informationAxpert-CSS AMTECH DRIVES Axpert-CSS Amtech
The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the
More informationHGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL
HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL SMARTGEN ELECTRONICS Smartgen Electronic Equipment Co., Ltd No.12 Dongqing Street Zhengzhou Henan Province P.R.China Tel : (0086)-371-67992951
More informationDKG-215 MANUAL AND REMOTE START UNIT
DKG-215 MANUAL AND REMOTE START UNIT FEATURES Manual and remote starting and stopping Zero power consumption at rest Engine control mode available Generator protection Built in alarms and warnings 1 phase
More informationHAT700 Series HAT700/HAT700I/HAT700B/HAT700BI/HAT700S ATS CONTROLLER USER MANUAL
HAT700 Series HAT700/HAT700I/HAT700B/HAT700BI/HAT700S ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD Software Version Version Date Note 1.0 2014-09-09 Original release. 1.1 2015-03-04
More informationOPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets
Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599
More informationHGM6410/6420. Automatic Generator Module. With J1939 Interface OPERATING MANUAL. Smartgen Electronics
HGM6410/6420 Automatic Generator Module With J1939 Interface OPERATING MANUAL Smartgen Electronics Smartgen Electronic Equipment Co,.Ltd No.12 Dongqing Street Zhengzhou Henan Province P.R.China Tel : (0086)-371-67992951
More informationDKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT
DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT FEATURES Automatic mains failure, Engine control, Gas engine support, Generator protection, Built in alarms and warnings, 3 phase mains voltage inputs
More informationEnergy Division
Energy Division http://energy.tycoelectronics.com Installation and Operating Manual GEN-TRANS Automatic Generator Transfer Switch Controller with Metering Tyco Electronics UK Limited Crompton Instruments
More informationPowerCommand 2100 digital generator set control
Specification sheet PowerCommand 2100 digital generator set control Description The PowerCommand 2100 control is a microprocessor-based generator set monitoring, metering and control system. The control
More informationENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER
ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER The engine/generator controller is an integrated genset controller contained in a single, easy to install package. The controller contains a microprocessor-based
More informationGenerator Sets Controller 210. Operation Manual. Ver1.0
Generator Sets Controller 210 Operation Manual Ver1.0 Note This information could include technical inaccuracies or typographical error. Manufacturer may make improvements and/or changes in the product(s)
More informationiguard Digital Generator Set Controller Installation and Operations Manual Section 75
iguard Digital Generator Set Controller Installation and Operations Manual 00-02-0522 09-24-12 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the
More informationPowerCommand 1.1 control system
Specification sheet PowerCommand 1.1 control system Description The PowerCommand control system is a microprocessor-based generator set monitoring, metering and control system designed to meet the demands
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4120 AUTO MAINS FAILURE MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel:
More informationRVS-DN Digital Reduced Voltage Motor Starter
RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationMODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM
MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...
More informationHGM6400 Automatic Genset Controller (With J1939 Interface) USER MANUAL Smartgen Technology
HGM6400 Automatic Genset Controller (With J1939 Interface) USER MANUAL Smartgen Technology Chinese trademark English trademark Smartgen make your generator smart Smartgen Technology Co., Ltd No. 28 Jinsuo
More informationThe measurements module provides the following engine features information:
1. INTRODUCTION The CEM6 control board is a monitoring network signal and monitoring and control generator feeding device. The device consists of 2 different modules: - Visualization module. The visualization
More informationDKG-509 AUTOMATIC MAINS FAILURE UNIT
DKG-509 AUTOMATIC MAINS FAILURE UNIT CANBUS AND MPU VERSIONS DESCRIPTION The controller is a comprehensive AMF unit for single genset standby or dual genset mutual standby operations. The unit is available
More informationGENSET PRODUCTS 013 2
GENSET PRODUCTS 2013 TECHNOLOGY IS NOW FOR EVERYONE D 700 COMMUNICATION CAPABILITIES AUTOMATIC MAINS FAILURE UNITS DKG 107 DKG 107 The lowest cost AMF module Factory set timers Adjustable AC low voltage
More informationUK MANUFACTURED GENERATORS PS100P PS150P PERKINS 1006 SERIES TECHNICAL DATA SHEET
UK MANUFACTURED GENERATORS PS100P PS150P PERKINS 1006 SERIES TECHNICAL DATA SHEET Head Office H # 2243, Markaz, I-10/2 Islamabad. 44000 Pakistan Tel: +92-51-4433933 Fax: +92-51-4102199 Lahore Office Mian
More informationDKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES
Genset Automation Control Pte Ltd DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES FEATURES Automatic mains failure, Remote start operation,
More informationProduct Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0
Product Manual Part Number: MVP-193 Mefi-6 ECU Revision: 1.0 Copyright Controls, Inc. P.O. Box 368 Sharon Center, OH 44274 Phone 330.239.4345 Fax 330.239.2845 www.controlsinc.com TABLE OF CONTENTS PRIOR
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE720 AUTOSTART CONTROL MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North
More informationKomatsu Power Generation Systems
Komatsu Power Generation Systems Komatsu Air-to-Air aftercooled engine Advanced Air-to-Air aftercooled Engines have been introduced. EGS Series Generators are mounted with Komatsu engines that have High
More informationGSC300 Auto Start Engine Controller
GSC300 Auto Start Engine Controller Revision 2.9 Installation and User Manual for the GSC300 Auto Start Engine Controller File: MAN-0039 R2.9, GSC300 User Manual.doc May 2011 2 of 29 Thank You For Purchasing
More informationRVS-DX Digital Reduced Voltage Motor Starter
RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationUK MANUFACTURED GENERATORS PS9P PS20P PERKINS 400 SERIES TECHNICAL DATA SHEET
UK MANUFACTURED GENERATORS PS9P PS20P PERKINS 400 SERIES TECHNICAL DATA SHEET Head Office H # 2243, Markaz, I-10/2 Islamabad. 44000 Pakistan Tel: +92-51-4433933 Fax: +92-51-4102199 Lahore Office Mian Ishaq
More informationGSC300 Auto Start Engine Controller
GSC300 Auto Start Engine Controller Revision 2.12 Installation and User Manual for the GSC300 Auto Start Engine Controller File: MAN-0039 R2.12, GSC300 User Manual.doc June 2014 2 of 28 Thank You For Purchasing
More informationPWM-High Voltage Charge controller. User s Manual. Models available: 72V to 240V in 20A or 40A
PWM-High Voltage Charge controller User s Manual Models available: 72V to 240V in 20A or 40A Introduction Congratulations! You are the proud owner of one of the best PWM charge controllers available in
More informationDEEP SEA ELECTRONICS
DEEP SEA ELECTRONICS DSE6010 MKII / DSE6020 MKII Configuration Suite PC Software Manual Document Number: 057-223 Author: Fady Atallah DSE6010 MKII / DSE6020 MKII Configuration Suite PC Software Manual
More informationPower (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/
General Characteristics Model Name AJD 33 Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model JOHN DEERE 3029DF128 Alternator Made and Model ECP 28-VL/4 A Control Panel Model 7320 Canopy AK 20 Power
More information2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY
2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY User Guide For Key WARNING It is the responsibility of the vehicle operator to ensure that their vehicle is parked in
More informationThis generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC
This generator set has been designed to meet ISO 8528 regulation. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 2000/14/EC 3 Phase
More informationOPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02
OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02 1. INTRODUCTION 2. SAFETY INSTRUCTIONS 3. SPECIFICATION 4. OPERATING INSTRUCTIONS AND CONTROL FUNCTIONS 5. SET UP PROCEDURE 6. CONNECTIONS
More informationDEEP SEA ELECTRONICS DSE7110 MKII / DSE7120 MKII Configuration Suite PC Software Manual
DEEP SEA ELECTRONICS DSE7110 MKII / DSE7120 MKII Configuration Suite PC Software Manual Document Number 057-185 Author: Fady Atallah DSE7110 MKII / DSE7120 MKII Configuration Suite PC Software Manual DSE7110
More informationDKG-109 AUTOMATIC MAINS FAILURE UNIT
Tel: +90-216-466 84 60 Fax: +90-216 364 65 65 datakom@datakom.com.tr http://www.datakom.com.tr DKG-109 AUTOMATIC MAINS FAILURE UNIT FEATURES Automatic mains failure Engine control Generator protection
More informationVoltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES
This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed
More informationPower Solution Supplier
Power Solution Supplier. Diesel & Gas Power Generators. Power Plant. Transformer Substation. CHP & CCHP System Guangdong Honny Power-Tech Co., Ltd GENERATOR FEATURE Engine and alternator shall be mounted
More informationStarting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F
Starting System DS-102 Series 200 Elmatik AS P.O.Box 309 NO-3471, Slemmestad T - +47 31 28 37 83 F - +47 31 28 37 93 www.elmatik.no post@elmatik.no CONTENT 1. INTRODUCTION 3 2. TECHNICAL SPECIFICATIONS
More informationGCU-10. Automatic Engine Control Unit Operators Manual
GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,
More informationEnclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00
This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed
More informationUSER S MANUAL AMF TRINITY. AMF Operational Manual
USER S MANUAL AMF This document contains the latest technical information about AMF. The unit is tested against latest "MTE" Standard Model PRS400.3 having basic accuracy of 0.02%, traceable upto International
More informationANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A
AKSA Power Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main
More informationThis generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More informationCENTAURI ENERGY SERVER TECHNICAL DATA kw POWER
Chassis Inverter power Rated input Rated output Battery pack Safeties Environment Others Input Voltage Lower Limit Input Voltage Upper Limit Power Input Current Output Voltage Output accuracy Transient
More informationStandby Amper VOLTAGE
INTRODUCTION Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More information