Instruction manual. 0 Manual Control and Switch Panel DT 201 B. Table of contents

Size: px
Start display at page:

Download "Instruction manual. 0 Manual Control and Switch Panel DT 201 B. Table of contents"

Transcription

1 Instruction manual 0 Manual Control and Switch Panel DT 201 B Control and switch panel DT 201 B Table of contents 1 Introduction Safety information Description and appropriate use Technical data Operation Starting up Maintenance Shutting down Technical faults, possible causes and remedies Circuit diagram - for specialist workshop only Customer service Fault report Schaudt GmbH, Elektrotechnik & Apparatebau, Daimlerstraße 5, Markdorf, Germany, Phone , Telefax , SDT EN (Valid from software version 2.16) Situation:

2 1 Introduction This instruction manual contains important information for the safe operation of the control and switch panel. It is essential to read and to follow the given safety information. The instruction manual should always be kept in the motorhome/caravan. All safety information must be passed on to other users. W Failure to comply with this sign may lead to the endangerment of persons. W Failure to comply with this sign may damage the unit or the connected consumers. W This sign indicates recommendations or special features. The reproduction, translation and duplication of this manual, even in parts, is not allowed without written authorization. 2 Safety information The design of the control and switch panel is state-of-the-art and according to approved safety technology regulations. Nevertheless, if the safety information in this instruction manual is not closely followed, persons might be injured or the control and switch panel might be damaged. Do not use the control and switch panel if it is not in technically good order and condition. The instruction manual must be followed. Any technical faults affecting the safety of persons or of the control and switch panel must be dealt with immediately by qualified personnel. W The electrical system of the motorhome or the caravan has to meet current DIN, VDE and ISO regulations. Manipulations of the electrical system will endanger the safety of persons and the vehicle, and are therefore prohibited. W Never make any modifications to the control and switch panel. W Connection work is to be carried out in tensionless condition only. W The electrical connection may only be established by qualified personnel and must be carried out according to the Schaudt installation instructions. W If the living area battery is totally discharged or overcharged for a lengthy period, it will be irreparably damaged. W Switch off the 12 V main switch when you leave the vehicle. This prevents the living area battery from unnecessarily discharging. W Before starting to drive, check if the step and the supports are retracted and if the roof hood is closed. If the sensors are defective or if the D+ signal is missing, the warning signal can fail. 2 Situation: SDT EN

3 3 Description and appropriate use The job of the control and switch panel DT 201 B is to control the electrical functions in the living area of the motorhome and display various values such as capacity, voltages, battery currents and water tank levels. This system includes: P P P An Electrobloc, consisting of a charger module, the 12 V distribution and the fuses for each circuit Tank sensors for measuring the level in the water tanks An outside temperature sensor Fig. 1 Control and switch panel DT 201 B 1 12 V main switch button 2 Tank button 3 Battery button 4 Basic display button 5 Display window 6 "MENUE" button, setting menu 7 "+" button (increase indicated value) 8 " " button (reduce indicated value) 9 "OK" button (selection/confirm settings) SDT00092 Buttons The various displays and menus are selected and settings made using the 8 buttons on the front of the control and switch panel. The control and switch panel must first be switched on using the 12 V main switch button, before the other buttons can be used. When the control and switch panel is switched on, the basic display is visible. If the basic display, tank or battery button is pressed, the corresponding display appears and is illuminated. 20 seconds after pressing the button for the last time, the basic display appears. It is not illuminated. The "MENUE" button must be pressed for more than 3 seconds to arrive at the desired setting menu. W The control and switch panel can only be switched on, if the living area battery voltage is above 11.0 V. W For more information, see the section 5.7. SDT EN Situation:

4 Symbols on the display Symbols, measured values and settings of the selected display are indicated in the display window SDT Fig. 2 Display window 1 Defroster switched on 2 Spare cylinder in use 3 Living area battery/inside temperature 4 Solar current 5 Setting menu 6 Battery and filling level alarm 7 Call up next page 8 Optical display for buzzer/warning that buzzer is switched off 9 12 V Off display (3 seconds) V power supply is connected 11 Water tank 12 Waste water tank 13 Fault display for battery, filling level sensors, temperature sensors 14 Starter battery/outside temperature/step 11 Calling up the next page If the arrow is visible in the display window, the next page can be called up with the basic display, tank, battery and menu buttons. 4 Technical data Operating voltage 12 V ( V), powered via Electrobloc 4 Situation: SDT EN

5 5 Operation 5.1 Switching the 12 V power supply for the living area on and off 12 V main switch button The 12 V main switch button switches all consumers and the control and switch panel on and off. Exceptions: P Floor light/step P Frost protection valve P Heater P Spare 4 P Compressor refrigerator/aes refrigerator Switching on Press the 12 V main switch button. The illuminated basic display appears and the system is ready for use. The basic display is illuminated for 20 seconds. If there is an alarm message, this is also indicated in the basic display. Switching off Press the 12 V main switch button. The system shuts down. The text "12 V OFF" appears for 3 seconds. W Switch off the 12 V main switch when you leave the vehicle. This prevents the living area battery from unnecessarily discharging. 5.2 Using the basic display Basic display button The basic display gives information on mains indicator, step, special equipment and temperature as well as date and time. Press basic display button. The 1st page of the basic display appears. SDT00095 Fig. 3 Basic display W If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated. 230 V mains indicator The 230 V mains indicator symbol is displayed, if the input of the Electrobloc is live and if the control and switch panel has been switched on using the 12 V main switch. SDT EN Situation:

6 Spare cylinder (optional) Defroster (optional) For additional equipment Truma Duomatic L plus: The spare cylinder symbol is displayed when one of the two gas cylinders is empty. The spare cylinder symbol flashes if the second gas cylinder is also empty. The "ALARM" message appears in the basic display. For additional equipment Truma Triomatic: The spare cylinder symbol is displayed when the gas cylinder in use is empty. For additional equipment Truma Duomatic L or Truma Triomatic: The "Eis-Ex" (defroster) symbol is displayed when the defroster unit is switched on. W For more information, see the instruction manual for the additional equipment. Step The step symbol is displayed when the step is extended. Before commencing the journey, the step must be retracted. W Before commencing the journey, check if the step is retracted. If the step is extended and the engine is started, a loud warning signal is emitted and the buzzer symbol appears on the display. If the sensors are defective or if the D+ signal is missing, the warning signal can fail. Before commencing the journey, the driver must therefore check if the step is retracted. W For more information, see the section Checking the temperatures Basic display button Press the basic display button twice briefly. The inside and outside temperatures are indicated on the 2nd page of the basic display. The display range is between -40 C and +60 C. W If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated. 6 Situation: SDT EN

7 5.2.2 Settings in the basic menu The defroster option can be switched on and off in the basic menu. Time, date and nominal battery capacity can also be set and software version and parameter number displayed. "MENUE" button In the basic display, press the "MENUE" button for more than 3 seconds. The 1st page of the basic display appears. The adjustable values flash in the display. P If the step alarm is emitted, it can be switched off on the 1st page (page is only visible if the warning signal is emitted). P If the defroster unit is installed, the defroster option can be switched on and off on the next page (page is only visible if the defroster unit is installed). P The time can be set on the next page. SDT00098 Fig. 4 Basic menu P P The date can be set on the next page. Software version and parameter number are displayed on the next page. Change the flashing value with the "+" or " " button. Press "OK" button. The entry of the new value is confirmed, the next adjustable value begins to flash and can be changed or confirmed. W If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated. Entries that are not confirmed with "OK" are not saved. W Changed values are only saved if the entry was confirmed using the "OK" button. If one switches to another display before pressing the "OK" button, the changed values are not saved. Press "MENUE" button. The next page is displayed. To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display. SDT EN Situation:

8 Defroster unit The defroster unit can be switched on and off or set to automatic operation in the basic menu. Depending on the setting, "ON", "OFF" or "AUTO" is indicated in the display window. This menu is only displayed if the defroster unit is installed. In automatic operation, the defroster unit is automatically switched on if the outside temperature falls below +7.5 C and automatically switched off if the temperature rises above +7.5 C. W Both defroster outputs are designed only for operation with the liquid gas control units Truma Duomatic L plus or Truma Triomatic and may only be used together with these units. The maximum load current for each output is 0.4 A. Setting the time Press the "MENUE" button for more than 3 seconds. The basic display is displayed. Press the "MENUE" button several times until the "TIME" page of the basic menu is displayed. The hour display flashes. Set the hours with the "+" or " " button. Press "OK" button. The hour entry is confirmed. The minute display flashes. Set the minutes with the "+" or " " button. Press "OK" button. The minute entry is confirmed. The time is set. Setting the date Press the "MENUE" button several times until the "DATE" page of the basic menu is displayed. The year display flashes. Set the year with the "+" or " " button. Press "OK" button. The entry of the year is confirmed. The day display flashes. Set the day with the "+" or " " button. Press "OK" button. The entry of the day is confirmed. The month display flashes. Set the month with the "+" or " " button. Press "OK" button. The entry of the month is confirmed. Software version and parameter number Press the "MENUE" button several times until the software version and the four-digit parameter number are displayed. These settings cannot be changed. W Software version and parameter number are required for queries at the dealer or customer service. Always have these settings ready for queries. W For the correct functionality, the parameter number must be modified if special equipment is installed at a later date. You can obtain further information at your dealer or at Schaudt GmbH customer service. To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display. Press "OK" button. 8 Situation: SDT EN

9 5.3 Battery display The battery display indicates the battery capacity and the load current of the living area battery as well as the battery voltage of living area battery and starter battery. If available, the solar current of living area battery and starter battery is also displayed. The control and switch panel is equipped with a real level display for the living area battery. The display of the battery capacity gives direct information on how much power is stored in the battery. Example: The battery has been fully charged (100 %) and the motorhome has not been connected to a 230 V power supply for 3 days. The display indicates 40 %. That means that the battery can supply the motorhome with power for about 2 more days. Other functions The following functions are also integrated: P P P P P P Automatic setting of the capacity display to "full" on reaching a full battery charge Warning if the battery capacity falls below 15 % of the nominal level. For more information see section Automatic determination of the maximum possible battery capacity (in Ah) for defined discharging of the battery Warning at the end of the battery service life (max. capacity reached: only 50 % of the nominal capacity) Charge request if the last full charge was more than 20 days ago Setting of the nominal capacity by the motorhome user (e.g. if a higher battery capacity is retrofitted) Checking battery capacity and load current Battery button Press battery button. Battery capacity and charge current of the living area battery appear on the 1st page of the battery display. SDT00097 Fig. 5 Battery display SDT EN Situation:

10 The battery capacity can be displayed in ampere hours (Ah) and percent (%). Switching between units Press "OK" button. The display of the battery capacity switches between the units ampere hours (Ah) and percent (%). The charging current of the living area battery is shown in amps (A). Positive values indicate the charging current. Negative values indicate the discharge current. W The illumination of the display requires approx. 0.4 A. This illumination current is added to the discharge current and displayed. W In order to register the entire power consumption, all consumers must be connected to the Electrobloc. If consumers are connected directly to the battery, the Schaudt system cannot register their power consumption. The indication of current, battery capacity and charge request are not correct in such an event. The battery display takes all types of battery charge into account in connection with the Electrobloc EBL 101: P Via the charger module of the 230 V mains P Via the cut-off relay of the alternator while driving P Via a solar charge regulator for the solar cells connected to the system Checking the battery voltage Battery button Press battery button twice briefly. The voltages of living area battery and starter battery appear on the 2nd page of the battery display. Voltage in the living area battery Voltage in the starter battery The off-load voltage of the starter battery is only displayed if the engine is switched off and if no consumers are using the starter battery. W If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated. Entries that are not confirmed are not saved. W In mobile operation, the voltage of the starter battery is indicated slightly too low, if the refrigerator is in use with 12 V. If the refrigerator is switched off or operated using gas, the voltage display of the starter battery is correct. In stationary operation, the voltage of the starter battery is also displayed correctly. 10 Situation: SDT EN

11 The following table will help you correctly interpret the living area battery voltages displayed by the control and switch panel. These values apply to actual operation, not off-load voltage and for lead gel batteries only. Battery voltage Description 10.5 or less P Risk of total discharge P The battery monitor switches off all consumers (apart from the frost protection valve) 11 V or more The 12 V power supply can be switched on using the main switch 10.5 V to 12 V P If the voltage falls below 12 V, the battery alarm is triggered P If the voltage remains under V 1) for more than 1 minute, the battery capacity is set to zero P If the voltage remains under V 1) for more than 5 minutes, the system is switched off 12 V to 13.2 V Battery off load More than 13.2 V Battery is being charged: Main charge 13.8 V constant Trickle charge voltage 14.3 V Final charging voltage (equalising charge) P 1 h for lead acid battery P 8 h for lead gel battery 1) depending on the current load W If the living area battery is totally discharged or overcharged for a lengthy period, it will be irreparably damaged. W If the 12 V power supply is overloaded, switch off some of the consumers. W Inactive consumers can gradually discharge the battery. Checking the condition of the battery Measuring the off-load voltage is an additional method of assessing the condition of the battery. Off-load voltage is the voltage of the charged battery in a passive state, with no current being supplied or drawn. Take the measurement several hours after the last charging. In the meantime, no significant load should have been placed on the battery, which means no current should have been drawn from it. If the off-load voltage of the battery is less than 12.0 V, there is a risk of total discharge. The following table will help you interpret the off-load voltage displayed. These values apply for lead gel batteries. Values for off-load voltage 12 V 0 % 12.2 V 25 % 12.3 V 50 % More than 12.8 V Full Charging condition of the battery SDT EN Situation:

12 Charge request CHARGE! The batteries should be fully charged every 4 weeks for a long service life. As a reminder a charge request is displayed 20 days after the last equalising charge. Connect the motorhome to the 230 V power supply. The batteries are charged. W For more information see section 5.7 as well as the instruction manual for the Electrobloc Displaying the solar current (optional) Battery button The solar current display is only possible with a solar charge regulator type LRS... of Schaudt GmbH. Press battery button three times briefly. The solar currents of living area battery and starter battery appear on the 3rd page of the battery menu: Solar current display of the living area battery Solar current display of the starter battery To exit the display, press any button or wait for 20 seconds until the display automatically switches to the basic display Displaying the maximum battery capacity of the living area battery The maximum battery capacity of the living area battery "Ah max" is displayed in the battery menu, but it cannot be set. The maximum capacity is set at the factory to 80 % of the nominal capacity. The control and switch panel also recalculates the battery capacity after every complete charging cycle (total charge and total discharge) and indicates the current value. This display applies only to the living area battery. Press battery button once briefly. Press the "MENUE" button for more than 3 seconds. The maximum battery capacity "Ah max" of the living area battery appears on the 1st page of the battery menu. To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display. W For more information, see the section Situation: SDT EN

13 5.3.5 Settings in the battery menu Displaying/setting the battery capacity The nominal battery capacity "Ah nom" can be adapted e.g. on retrofitting a battery. The setting range is between 50 Ah and 495 Ah (K100 value). The standard setting ex works is 90 Ah. Press battery button once briefly. Press the "MENUE" button for more than 3 seconds. The 1st page of the battery menu is displayed. The maximum battery capacity "Ah max" is displayed. Press "MENUE" button a second time. The 2nd page of the battery menu is displayed. The display of the battery capacity flashes. Enter the new battery capacity of the living area battery with the "+" or " " button. It can be read off at the battery as K value. If no K100 value is indicated, the K20 value can be read off and multiplied by Confirm the set value with the "OK" button. To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display. W Changed values are only saved if the entry was confirmed using the "OK" button. If one switches to another display before pressing the "OK" button, the changed values are not saved. W If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated. 5.4 Battery monitor Automatic disconnector The battery monitor compares the living area battery voltage to a reference voltage. Monitoring is continued, even when the control and switch panel is switched off. Depending on the current drain an alarm message is displayed or the system is shut down sooner or later. This improves protection against total discharge of the battery. As soon as the battery voltage falls below 10.5 V to 12 V (depending on the discharge current), an alarm message appears in the display window. As soon as the battery voltage falls below 10.5 V, all 12 V consumers are immediately switched off. Only the frost protection valve is still powered. The control and switch panel also shuts down. Before shutting down, all switching conditions and the battery capacity value are saved. The automatic disconnector is not triggered by short-term low voltage, caused by high current when switching on consumers. If an overload or an insufficiently charged living area battery causes the voltage to fall so low that the automatic disconnector is triggered, any consumers which are not essential should be switched off. You may be able to switch on the 12 V power supply for a short time. Press the 12 V main switch button. The 12 V power supply is switched on. SDT EN Situation:

14 If the battery voltage remains below 11.0 V, you cannot switch on the 12 V power supply. The battery symbol and "CHARGE!" flash. The battery voltage is also displayed. Fully charge up the living area battery as soon as possible. W The saved switching conditions and the battery capacity value are restored on switching the unit on. W For more information, see the section 5.7 and the table "Battery voltage". 5.5 Tank display The tank level can be indicated and the tank alarm switched on and off in the tank display Checking the tank level Tank button Press tank button. SDT00096 Fig. 6 Tank display The tank level is indicated as a numerical value in steps of 0 %, 25 %, 50 %, 75 % and 100 % and also as graphical symbol with 1 to 4 filling level marks. Filling level of the water tank Filling level of the waste water tank 14 Situation: SDT EN

15 The following table will help you correctly interpret the tank levels indicated by the symbols. Symbol on display Tank level Full or almost full Roughly 3/4 full Roughly 1/2 full Roughly 1/4 full Empty or almost empty Settings in the tank menu Tank alarm The tank alarm can be switched on and off in the tank menu. In the tank display, press the "MENUE" button for more than 3 seconds. The tank menu is displayed. Switch the tank alarm on or off with the "+" or " " button. When the tank alarm is switched on, "ON" appears in the display window. When the tank alarm is switched off, "OFF" appears. Press "OK" button. The entry is confirmed. W If no button is pressed for 20 seconds, the system automatically switches back to the basic display that is not illuminated. W For more information, see the section Tank monitor The tank monitor checks the water tank and waste water tank levels. This check is carried out every minute or on switching to the tank display. As soon as the water tank is empty or the waste water tank is full, the tank alarm is triggered. The water tank is not monitored if the 12 V power supply of the consumers is switched off and while driving. W For more information, see the section 5.7. SDT EN Situation:

16 5.7 Alarm messages Alarm messages are indicated in the basic display by a flashing warning triangle and the corresponding symbol. In addition, the display window lights up for 20 seconds. More information on the alarm message is displayed in the battery menu and tank menu. If there are multiple alarm messages, they are indicated simultaneously with the corresponding symbols Living area battery alarm The battery alarm is triggered if the living area battery is nearly totally discharged or if the battery exceeds its gassing limit during the charging process due to overvoltage (U batt > approx V). W If the living area battery is totally discharged for a lengthy period, it will be irreparably damaged. W If the voltage is too high, the living area battery will be irreparably damaged. Total discharge If the living area battery voltage falls below the critical limit of 12 V to 10.5 V (depending on the current drain), the warning triangle and the word "ALARM" flash in the basic display. The living area battery symbol and the charge request "CHARGE!" also flash. Switch off all consumers. Recharge the living area battery by driving or by connecting it to the 230 V mains. W If the battery is empty, the control and switch panel cannot be switched on. As soon as the 12 V main switch button is pressed, the charge request "CHARGE!" and the battery symbol flash. The motorhome symbol and the battery voltage are also indicated. W For more information see section 5.4, the table "Battery charge" as well as the instruction manual for the Electrobloc. Overvoltage If there is overvoltage and therefore a risk of the living area battery falling below its gassing limit (U batt > approx V), the warning triangle and the word "ALARM" flash in the basic display. The living area battery symbol and the charge request "CHARGE!" also flash. The battery voltage value flashes in the display. Interrupt the charging of the battery, disconnect the battery from the 230 V power supply. Call customer service. W For more information see section 5.4, the table "Battery charge" as well as the instruction manual for the Electrobloc. 16 Situation: SDT EN

17 5.7.2 Battery capacity alarm for the living area battery CHARGE! The battery capacity alarm is triggered when the capacity of the living area battery falls below 15 % of the nominal capacity. The motorhome symbol is indicated in the basic display with a flashing battery symbol. The battery display also indicates the battery capacity and the charge request "CHARGE!". Recharge the living area battery by driving or by connecting it to the 230 V mains Charge request (instruction) CHARGE! DATE The motorhome symbol is indicated in the basic display with a flashing battery symbol 20 days after the last equalising charge. The battery menu also displays the charge request "CHARGE!", the word "DATE" and the battery capacity. The battery should be fully charged every 4 weeks for 24 hours to maintain its full capacity. Fully charge the living area battery by driving or by connecting it to the 230 V mains Battery defect message for the living area battery DEFECT Batteries lose their capacity due to ageing and wear. The battery defect message is displayed as soon as the maximum capacity falls below 50 % of the preset nominal capacity "Ah nom ". The motorhome symbol with a flashing battery symbol and the message "DEFECT" are indicated in the basic display. The living area battery has reached its maximum service life. Check the battery and install a new living area battery, if required Message for undefined battery capacity If the charge status of the battery is not known (e.g. after starting up the system for the first time or after changing the batteries), a "?" is displayed as capacity value. In addition, the charge request "CHARGE!" is displayed. Recharge the living area battery by connecting it to the 230 V mains for at least 24 hours. After completion of the charging process, disconnect the battery from the mains. Push any button. After approx. 30 seconds the "?" disappears. W For more information see the instruction manual for the Electrobloc. SDT EN Situation:

18 5.7.6 Tank alarm If the water tank level falls below 12 % or if the waste water tank level exceeds 87 %, the warning triangle, the word "ALARM" and the tank symbol flash in the basic display. The tank symbol and the tank level percentage indicator also flash in the tank display. Fill up water tank or drain waste water tank. W If the water tank remains empty due to an external water supply, the tank alarm can be switched off. W For more information, see the section Step alarm W Before commencing the journey, check if the step is retracted. Before commencing the journey, the step must be retracted. If the step is not retracted, a loud warning signal is emitted and the buzzer symbol appears on the display when the engine is started. If the sensors are defective or if the D+ signal is missing, the warning signal can fail. Before commencing the journey, the driver must therefore check if the step is retracted. False step alarm In exceptional cases, there can be a false alarm: The step alarm is triggered, even though the step is retracted. If such a malfunction occurs, the acoustic warning signal can be switched off after starting the engine. In the basic display, press the "MENUE" button for more than 3 seconds. Set the buzzer to "OFF" with the "+" or " " button of the basic menu. Confirm the entry with "OK". To exit the menu, press any button or wait for 20 seconds until the display automatically switches to the basic display. Have the malfunction rectified by the dealer. W The acoustic warning signal must be switched off after every engine start, until the malfunction has been rectified Mains alarm If the 230 V power supply fails or if it is disconnected from the motorhome, the 230 V symbol flashes. As soon as the 230 V power supply has been restored, the symbol lights up and remains illuminated. The symbol goes out as soon as the engine is started. Switching off the flashing symbol Press "OK" button. The mains alarm is confirmed. The symbol goes out. 18 Situation: SDT EN

19 5.7.9 Gas alarm For additional equipment Truma Duomatic L plus: If one of the two gas cylinders is empty, the spare cylinder symbol appears in the basic display. As soon as the second gas cylinder is empty, the spare cylinder symbol and the "ALARM" message appear Tank sensor fault message If there is a malfunction of the water or waste water sensors, a "?" flashes in the tank display. Clean the tank sensors of the respective tank. If the fault message is still displayed after cleaning, customer service must be informed Temperature fault message If there is a malfunction of the temperature sensors or if a temperature is not within the range of between -40 C and +60 C, a "?" is indicated in the temperature display Date message DATE If no date has been entered in the basic menu, the word "DATE" flashes. The date display is required for the capacity display to work properly. 6 Starting up The control and switch panel DT 201 B can only be started up with the Electrobloc EBL 101 and the accessories for measuring the water tank levels. Starting up the system Set the battery cut-off switch on the Electrobloc to "Batterie Ein" (battery on). Follow the instruction manual of the Electrobloc. Press the 12 V main switch on the control and switch panel. W After switching on the battery cut-off switch or after changing batteries: Switch on the 12 V main switch on the control and switch panel briefly to start up the consumers. After shutting down If the battery is disconnected from the system (battery cut-off switch is turned off on the Electrobloc or a battery pole is disconnected): Check the off-load voltage of the battery immediately after start up. Do not connect the vehicle to the 230 V mains, do not start the engine and do not switch on any consumers until the off-load voltage of the battery has been checked. After an off-load time of maximum 6 months, the battery voltage should be above 12.7 V if the battery was fully charged before shut down. If voltage is below 12.0 V then the battery might be defective and need to be replaced. W Connection work is to be carried out in tensionless condition only. SDT EN Situation:

20 7 Maintenance The control and switch panel requires no maintenance. Cleaning Clean the front plate of the control and switch panel with a soft, slightly damp cloth and a mild detergent. Never use spirit, thinners or similar substances. Do not allow any fluid to penetrate the inside of the control and switch panel. 8 Shutting down W Before using the battery cut-off switch on the Elektrobloc or before disconnecting the living area battery from the 12 V power supply, the 12 V power supply must be switched off with the 12 V main switch on the control and switch panel! Switch off the system if you are not going to use the motorhome for a lengthy period (for example during the winter). Shutting down the system for up to 6 months Shutting down the system for more than 6 months Disconnecting the living area battery from the 12 V power supply Fully charge up the living area battery before shutting down the system. The living area battery is then protected against total discharge. This applies only if the battery is intact. Follow the instructions of the battery manufacturer. Carry out the following work steps in the correct order: 1. Switch off the 12 V main switch on the control and switch panel. 2. Turn off the battery cut-off switch on the Electrobloc. Fully charge up the living area battery and remove the connecting terminals on the battery poles. Carry out the following work steps in the sequence mentioned below. The battery alarm is then no longer active. Carry out the following work steps in the correct order: 1. Switch off the 12 V main switch on the control and switch panel. 2. Turn off the battery cut-off switch on the Electrobloc. 3. Remove the clamps from the battery poles. W For other shutdown tasks, see the instruction manual for the Electrobloc. 20 Situation: SDT EN

21 9 Technical faults, possible causes and remedies If you are unable to solve a fault using the following tables, please contact our customer service address. If this is not possible, e.g. if you are abroad, you can have the control and switch panel repaired at a specialist workshop. Inexpert repairs invalidate the guarantee for the control and switch panel and Schaudt GmbH takes no liability for any resulting damage. Fault Possible cause Remedy 12 V power supply does not work No voltage in living area battery Step alarm even though the step is retracted 12 V main switch turned off Switch on the 12 V main switch Living area battery is discharged The battery can be discharged by inactive consumers such as the frost protection valve in the heater system Defective sensors or missing D+ signal Charge the living area battery immediately W If the living area battery is totally discharged for a lengthy period, it will be irreparably damaged Fully charge the living area battery before you shut down the motorhome for any lengthy period Switch off the acoustic warning signal (see the section 5.7) and contact customer service SDT EN Situation:

22 10 Circuit diagram - for specialist workshop only X1 X2 X3 X4 X5 X6 X7 X8 X Fig. 7 Circuit diagram for control and switch panel DT 201 B SDT00093 Plug assignment for the circuit plan X1 ELCO x to gas cylinders X2 ELCO x to gas cylinders 1. Negative defroster 1. Negative defroster 2. + Defroster 2. + Defroster 3. Spare gas 1 3. Spare gas 2 X3 Lumberg MSFQ/0 6 x to water tank X4 Lumberg MSFQ/0 5 x to waste water tank 1. Full 1. Full 2. 3/4 2. 3/4 3. 1/2 3. 1/2 4. 1/4 4. 1/4 5. Base water tank 5. Base waste water tank 6. Not assigned X5 Lumberg MSFQ/0 12 x to Electrobloc BL 3 X6 Lumberg MSFQ/0 7 x to Electrobloc BL 9 1. Main switch relay 1 OFF 1. D+ base 2. Main switch relay 1 ON 2. Not assigned 3. Main switch relay 2 OFF 3. Not assigned 4. Main switch relay 2 ON 4. Not assigned 5. Mains indicator 5. Not assigned 6. Shunt consumer 6. Signal solar starter battery 7. Shunt battery 7. Signal solar living area battery 8. Negative living area battery sensor X7 Lumberg MSFQ 2 x (3114) to 9. Negative lighting outside temperature sensor Living area battery sensor 1. Connection Starter battery 2. Connection Lighting X8 Lumberg MSFQ 3 x to capacity tank rod sensor 1. Signal capacity tank rod sensor 1. Negative 2. Negative capacity tank rod sensor 2. Step 3. + Capacity tank rod sensor 3. Not assigned 4. Not assigned X9 RIA plug-in/screw-type terminal type 09 4 x to limit switch 22 Situation: SDT EN

23 11 Customer service Customer service address Sending in the device Disposal instruction Schaudt GmbH, Elektrotechnik & Apparatebau Daimlerstraße Markdorf Germany Phone: kundendienst@schaudt-gmbh.de Opening hours Mon to Thu Fri Returning a defective device: 8 to 12 a.m., 1 to 4 p.m. 8 to 12 a.m. Use ESD protective bag and well-padded packaging. If there is no ESD protective bag, ask Schaudt GmbH for a suitable protective bag. Fill in and enclose the fault report, see section 12. Send it to the addressee delivered free. When the product service life is over, dispose of the device in accordance with the applicable regulations. SDT EN Situation:

24 12 Fault report In the event of damage, please return the defective device together with the completed fault report. Device type: Type no.: (please enter) DT 201 B There is the following defect: (please tick) The following electrical consumers do not work: Malfunction of control and switch panel Tank Voltage/current Which display? Constant fault Temporary fault/loose contact Other remarks: 24 Situation: SDT EN

Instruction manual. 0 manual for LT A control and switch panel. Table of contents

Instruction manual. 0 manual for LT A control and switch panel. Table of contents Instruction manual 0 manual for LT 109-4 A control and switch panel LT 109-4 A control and switch panel Table of contents 1 Introduction..........................................2 2 Safety information.....................................2

More information

Instruction manual. Electrobloc EBL 269

Instruction manual. Electrobloc EBL 269 Instruction manual 0 Manual Electrobloc EBL 69 Electrobloc EBL 69 Table of contents Introduction.......................................... Safety information..................................... Description

More information

Instruction Manual. Control and Display Panel DT 220 C. Table of contents

Instruction Manual. Control and Display Panel DT 220 C. Table of contents Instruction Manual Control and Display Panel DT 220 C Table of contents 1 Introduction... 2 2 Operation... 2 2.1 Design... 2 2.2 Controls and displays... 2 2.3 Restarting (after shutting down)... 6 2.4

More information

Instruction manual. Electrobloc EBL 109-6

Instruction manual. Electrobloc EBL 109-6 Instruction manual Electrobloc EBL 109-6 Table of contents 1 Introduction... 2 2 Safety information... 2 2.1 Significance of the warning signs... 2 2.2 General safety instructions... 2 3 Application and

More information

Instruction Manual. Electrobloc EBL 40 B

Instruction Manual. Electrobloc EBL 40 B Instruction Manual Electrobloc EBL 40 B Table of contents 1 Safety Information... 2 1.1 Meaning of safety symbols... 2 1.2 General safety information... 2 2 Introduction... 3 3 Operation... 3 3.1 Starting

More information

Operating Instructions

Operating Instructions Operating Instructions LRM 1218 Solar Charge Regulator Table of contents 1 Safety information... 2 1.1 Meaning of safety symbols... 2 1.2 General safety information... 2 2 Introduction... 3 2.1 Purpose...

More information

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7 EBL 208, Art.-No 911.430 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7 EBL 99 C, Art.-Nr. 911.413 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

Instruction Manual. Electroblock EBL 119 EBL 119 with OVP. Table of contents

Instruction Manual. Electroblock EBL 119 EBL 119 with OVP. Table of contents Instruction Manual Electroblock EBL 9 EBL 9 with OVP Table of contents Safety information.... Meaning of safety symbols.... General safety information... Introduction... Operation.... Starting up the system....

More information

Operating Instruction Manual for Instrument Panel IT 992 Art.-Nr Page 1 / 5

Operating Instruction Manual for Instrument Panel IT 992 Art.-Nr Page 1 / 5 Art.-Nr. 930.420 Page 1 / 5 Contents 1. Description 2. Safety Infmation 3. Operating Instructions and Display 4. Transpt, Stage, Installation 5. Electrical Installation 6. Power-Up, Maintenance 7. Enclosure

More information

Instruction manual. CSV 402 caravan power supply. Table of contents

Instruction manual. CSV 402 caravan power supply. Table of contents Instruction manual CSV 402 caravan power supply Table of contents 1 Introduction... 2 2 Safety information... 2 2.1 Significae of the warning signs... 2 2.2 General safety instructions... 2 Application

More information

Instruction Manual. Caravan Charging System CSV 404. Table of contents

Instruction Manual. Caravan Charging System CSV 404. Table of contents Instruction Manual Caravan Charging System CSV 404 Table of contents 1 Introduction... 2 2 Safety information... 2 2.1 Meaning of safety symbols... 2 2.2 General safety information... 2 3 Operation...

More information

Installation instructions. Adapter AD 01 AD 02 AD 03

Installation instructions. Adapter AD 01 AD 02 AD 03 Installation instructions Adapter AD 0 AD 0 AD 03 Table of contents Safety information..... Meaning of safety symbols... General safety information... 3 Introduction... Operation... 3 3. 4 Operating faults...

More information

Instruction Manual. Caravan Charging System CSV 414. Table of contents

Instruction Manual. Caravan Charging System CSV 414. Table of contents Instruction Manual Caravan Charging System CSV 414 Table of contents 1 Introduction... 2 2 Safety information... 2 2.1 Meaning of safety symbols... 2 2.2 General safety information... 2 Operation....1

More information

Installation and Connection: Installation and Operating Manual

Installation and Connection: Installation and Operating Manual Installation and Operating Manual LCD Battery Computer 100 S with Measuring Shunt 100 A No. 1262 LCD Battery Computer 200 S with Measuring Shunt 200 A No. 1265 LCD Battery Computer 400 S with Measuring

More information

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01 SI AT A22 English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and

More information

TRADE PRODUCTS. Electronic systems for recreational vehicles Supplying controlling indicating

TRADE PRODUCTS. Electronic systems for recreational vehicles Supplying controlling indicating TRADE PRODUCTS Electronic systems for recreational vehicles Supplying controlling indicating All systems under control Monitoring and controlling systems by Schaudt leading in safety and comfort in recreational

More information

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03 SI AT A22 English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and

More information

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply

More information

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Match 19 GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19 UPS. Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

PURE SINE WAVE DC TO AC POWER INVERTER

PURE SINE WAVE DC TO AC POWER INVERTER PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read

More information

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

D Dräger Alcotest 3000 Breath Alcohol Measuring Device D Dräger Alcotest 3000 Breath Alcohol Measuring Device Instructions for Use ST-14138-2008_sw.eps Table of Contents For Your Safety....................................... 3 Intended Use..........................................

More information

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

D2020N. Negative Ground 20A Max. Charge 20A Max. Load. Advanced Solar Charge Controller. DINGO User Guide. Read this before installing. Ver 1.

D2020N. Negative Ground 20A Max. Charge 20A Max. Load. Advanced Solar Charge Controller. DINGO User Guide. Read this before installing. Ver 1. D2020N Negative Ground 20A Max. Charge 20A Max. Load Advanced Solar Charge Controller DINGO User Guide Read this before installing Ver 1.5 031017 2 This is not an MPPT device: There is no voltage conversion.

More information

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings

ENGLISH SAFETY INSTRUCTIONS. Recommendations for safe operation. Operator safety. General warnings Safety and use instructions LifeSpeed iq TM - 3-phase chargers ENGLISH SAFETY INSTRUCTIONS GOALS OF THIS MANUAL This manual is aimed at any authorized personnel wanting to use a 3-phase LifeSpeed iq TM

More information

FlexCharger Battery Chargers

FlexCharger Battery Chargers FlexCharger Battery Chargers Operating Instructions Definitions (as used in these instructions) Flooded Battery Lead-acid battery with liquid electrolyte that requires open-venting and regular water replacement.

More information

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Installation and Operating Instructions. MPPT Solar System Controller ISC3040 Installation and Operating Instructions MPPT Solar System Controller ISC3040 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

PL User Guide. PL User Guide. Advanced Solar Charge Controller. Simple, easy to read. User Guide. Read this before installing BOOST

PL User Guide. PL User Guide. Advanced Solar Charge Controller. Simple, easy to read. User Guide. Read this before installing BOOST PL Advanced Solar Charge Controller Simple, easy to read User Guide Read this before installing Ah BOOST 2 Ah BOOST SOLAR CONTROLLER PL20 BATTERY CHARGE PL40 12-48V CONTROLLER 20A CHARGE BAT+ 40A CHARGE

More information

Installation and Operating Instructions. Solar System Controller ISC3020

Installation and Operating Instructions. Solar System Controller ISC3020 Installation and Operating Instructions Solar System Controller ISC3020 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s of

More information

USER MANUAL MPS 1-5KW SERIES

USER MANUAL MPS 1-5KW SERIES USER MANUAL MPS 1-5KW SERIES Low Series Frequency Solar and Wind Power Charging Inverter CONTENTS 1 WWW.NEXTGENNRG.COM 1. Introduction... 3 2. Profile Structure 4 2.1. Working Principle 4 2.2.Product Features..5

More information

Battery charger , A, B

Battery charger , A, B Battery charger 420.093.050, 420.093.050.A, 420.093.050.B Battery charger 420.093.050, 420.093.050.A, 420.093.050.B englisch 12.09 2009 AUDI AG AUDI AG works continuously to develop and further improve

More information

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer, Phocos CML-V2 Solar charge controller User Manual (English) Dear customer, Thank you very much for buying this Phocos product. Please read the instructions carefully and thoroughly before using the product.

More information

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5 OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER Version 1.5 1 Product Overview EMBC-8025 is an intelligent switching mode battery charger with float maintenance. It is designed to offer maximum

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

SC-Max 48V series. User Manual. Solar Charge Controller 30A

SC-Max 48V series. User Manual. Solar Charge Controller 30A SC-Max 48V series Solar Charge Controller 30A User Manual Contents 1 Description of function 2 Safety Instructions and Waiver of Liability 2.1 Safety 2.2 Liability Exclusion 3 Dimensions 4 Optional 4.1

More information

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.: Operating manual HDA eco Box 12/24V DC Automatic Dispenser Item No.: 110 500 900 Translation of the original operating manual Important! Copyright The operating manual is always to be read before commissioning

More information

Eclipse Solar Suitcase

Eclipse Solar Suitcase Eclipse Solar Suitcase Renogy 100W 200W 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.0 Important Safety Instructions Please save these instructions. This manual contains important

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

Installation and Operating Instructions. Solar System Controller ISC3030

Installation and Operating Instructions. Solar System Controller ISC3030 Installation and Operating Instructions Solar System Controller ISC3030 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s of the

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Ignition Key, Remote Control Key

Ignition Key, Remote Control Key Ignition Key, Remote Control Key TABLE OF CONTENTS Remote Control Key* and Ignition Key... - Remote Control Key Functions... - Key Functions... - Immobilizer System*... - Opening and Closing the Doors

More information

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

FUM-24xxCBP Series 3 Stage Battery Charger User Manual FUM-24xxCBP Series 3 Stage Battery Charger User Manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct use

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions AQUATEC R / AQUATEC F / AQUATEC XL Bathlift Operating instructions 1 2 3 4 5 6 7 8 9 10 11 Contents 1 General instructions................. 3 1.1 Introduction......................... 3 1.2 Proper use.........................

More information

Remote Engine Starter System I User s Information Manual

Remote Engine Starter System I User s Information Manual Remote Engine Starter System I User s Information Manual A Few Words About Safety Your safety, and the safety of others, is very important. Operating this Remote Engine Starter System safely is an important

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

Your new LM controller is a state-of-the art device which was developed in accordance with the latest CAP LM-series Solar charge controller User Manual Thank you very much for buying this CAP product. Please read the instructions carefully and thoroughly before using the products. Your new LM controller

More information

INSTRUCTION AND USE MANUAL

INSTRUCTION AND USE MANUAL CONTROL UNITS FOR ENGINE CONTROL AND PROTECTION TYPE CEP-090 INSTRUCTION AND USE MANUAL It is equipped with display to show the INSTRUMENTS: - hour-meter - fuel level indicator - tachometer - battery voltmeter

More information

Original Operating Manual

Original Operating Manual 2010-10-29 Original Operating Manual Control Panel Comfort for Pedelecs Series 4313 Save for future use! Marquardt GmbH Schlossstraße 16 78604 Rietheim-Weilheim E-mail: marquardt@marquardt.de Website:

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9 USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.

More information

OPERATIONS MANUAL CR Thermoreactor

OPERATIONS MANUAL CR Thermoreactor OPERATIONS MANUAL CR 2200 Thermoreactor CR 2200 Note For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI 1725 Brannum Lane Yellow Springs, OH 45387 USA Tel: +1 937-767-7241

More information

Installation and Operating Manual

Installation and Operating Manual Installation and Operating Manual VPC Jupiter 100 with Measuring Shunt 100 A No. 5747 VPC Jupiter 200 with Measuring Shunt 200 A No. 5748 VPC Jupiter 400 with Measuring Shunt 400 A No. 5749 The VPC Jupiter

More information

Solar System Controller

Solar System Controller POWER FAULT 50 Amp MPPT Installation and Operating Instructions Solar System Controller ISC5040 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference

More information

Installation and Operating Manual Solar Controller

Installation and Operating Manual Solar Controller Installation and Operating Manual Solar Controller MPP 320 Duo Digital Li (12 V / 24 A / 320 Wp) No. 098103037 MPP 420 Duo Digital Li (12 V / 32 A/ 420 Wp) No. 098103039 MPP 320/24 Duo Digital Li (24 V

More information

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5

More information

SBC / 2140 / Stage Battery Charger User Manual

SBC / 2140 / Stage Battery Charger User Manual SBC - 2130 / 2140 / 2150 3 Stage Battery Charger User Manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct

More information

EC400 Power Control System

EC400 Power Control System 1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in section 3 or in the supporting technical manual available

More information

Tips & Technology For Bosch business partners

Tips & Technology For Bosch business partners Tips & Technology For Bosch business partners Current topics for successful workshops No. 75/2014 Electrics / Electronics Starter batteries Information and tips Tasks and requirements The starter battery

More information

EC200 ELECTRONIC CONTROL SYSTEM

EC200 ELECTRONIC CONTROL SYSTEM 1 INTRODUCING THE EC200 ELECTRONIC CONTROL SYSTEM With the use of new technology and an innovative approach to user interfacing, the EC200 Power Control System provides a complete control solution for

More information

Owner s Manual. Solar Controller GP-PWM-30

Owner s Manual. Solar Controller GP-PWM-30 Owner s Manual Solar Controller GP-PWM-30 1.0 Installation Overview 1.1 Introduction A Solar Controller (or Charge Controller / Regulator) is an essential component of your photovoltaic solar system. The

More information

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual c-go 12V/10A 12V/20A Power supply and battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Mounting and installation... 4 4. Operation... 5 5. Problem solving...

More information

Instructions for use. Hawker Premier

Instructions for use. Hawker Premier Instructions for use GB Hawker Premier Instructions for use Hawker Premier system ENGLISH The Hawker Premier system integrates a battery with airmixing system and aquamatic system, an on-board electronic

More information

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1 MEGA 2700 2-WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1 2 WARNINGS: As with any product that performs automatic functions, there

More information

SmartON / SmartON+ Installation and Use Manual

SmartON / SmartON+ Installation and Use Manual SmartON / SmartON+ Installation and Use Manual Rev. Date Ver. Ver. Notes document document SmartON SmartViewII 1.0 06/04/2007 3.08 2.30 Pre-release 1.01 10/04/2007 3.08 2.30 Release 1.02 04/10/2007 3.09

More information

Important instructions

Important instructions Operation manual Please read this manual, before starting the unit. It contains important notes on commissioning and handling. Keep these instructions for future reference. Be careful even if you pass

More information

MP V 8A Electronic Smart Charger. Instruction and Information Manual

MP V 8A Electronic Smart Charger. Instruction and Information Manual MP7428 12V 8A Electronic Smart Charger Instruction and Information Manual In order to ensure correct and safe usage of your battery charger, you should read these instructions carefully. Please retain

More information

INTRODUCTION. Specifications. Operating voltage range:

INTRODUCTION. Specifications. Operating voltage range: INTRODUCTION INTRODUCTION Thank you for purchasing the EcoPower Electron 65 AC Charger. This product is a fast charger with a high performance microprocessor and specialized operating software. Please

More information

U n i n t e r r u p t i b l e P o w e r S y s t e m

U n i n t e r r u p t i b l e P o w e r S y s t e m SMART ON-LINE UPS User s Manual U n i n t e r r u p t i b l e P o w e r S y s t e m Smart On-Line UPS 2KVA ~ 20KVA 20KVA Exhaust hole (16)Main breaker (12)Heat exhaust hole (15)Telephone (Rj11) or network

More information

Rev. U8e PL80e. Advanced PWM Solar Charge Controller. User Guide. Read this before installing. Solar Charge Controller

Rev. U8e PL80e. Advanced PWM Solar Charge Controller. User Guide. Read this before installing. Solar Charge Controller Rev. U8e. 19092017 PL80e Advanced PWM Solar Charge Controller User Guide Read this before installing PL80e Solar Charge Controller 12-48V 80A Charge 40A Load PLASMATRONICS PLASMATRONICS 2 PL80e User Guide

More information

Fast Charger SL01/02

Fast Charger SL01/02 Fast Charger SL01/02 User Manual This manual contains important information for commissioning and handling. Please read them first before use of the SL01 or SL02 and keep these instruction, so you can

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

MPPT5012A-DUO-BT MPPT5025A-DUO-BT

MPPT5012A-DUO-BT MPPT5025A-DUO-BT MPPT Dual batterysolar controller User Manual MPPT5012A-DUO-BT MPPT5025A-DUO-BT Thank you very much for buying our product,please read thoroughly before using the prouuct Description of Functions 1. Increased

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION

RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION Introduction Congratulations and thank you for purchasing Marlec s HRDi Charge Regulator. This is the latest technology for charge regulation of

More information

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside

More information

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation

More information

DINGO PUP. Negative Ground 20A Max. Charge 20A Max. Load. Dingo Series Expansion Unit. User Guide. Read this before installing. Ver 1.

DINGO PUP. Negative Ground 20A Max. Charge 20A Max. Load. Dingo Series Expansion Unit. User Guide. Read this before installing. Ver 1. DINGO PUP Negative Ground 20A Max. Charge 20A Max. Load Dingo Series Expansion Unit User Guide Read this before installing Ver 1.6 230317 2 Pup configuration: Each Pup must have its own address. Configure

More information

Operating instructions

Operating instructions 76 307 Model-Nr. AT596 Battery-operated windscreen de-icer PLUS 12 V Operating instructions Hergestellt für: INTER-UNION Technohandel GmbH Klaus-von-Klitzing-Str. 2 76829 Landau Germany www.inter-union.de

More information

PWM Charge Controller with LCD Display 30A. User Manual

PWM Charge Controller with LCD Display 30A. User Manual PWM Charge Controller with LCD Display 30A User Manual 1 Product Features 1. 12V/ 24 V system voltages are automatically recognized. 2. Charging program options for sealed, GEL and flooded lead-acid batteries

More information

Solar Hybrid Inverter SP Brilliant Series

Solar Hybrid Inverter SP Brilliant Series User Manual Solar Hybrid Inverter SP Brilliant Series Version: 1.5 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System

More information

Operating Instructions

Operating Instructions Operating Instructions Lubricus Lubrication System LUB - M (24 VDC) Operating Instructions: LUB- M Table of Contents Contents 2 1) General Information 4 1.1 Warning 4 1.2 Scope of supply 4 1.3 Overview

More information

EC328 Power Control System

EC328 Power Control System 1 Key Features Battery Charger / Power Supply Incorporates an air cooled 300 Watt multi-stage power converter unit that charges the batteries and provides 12V DC power. Built-in dual Solar Regulator -

More information

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller User Manual 4KVA/ 5KVA INVERTER / CHARGER With MPPT Controller CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775 URL : http://www.kutai.com.tw

More information

Owner s Manual. Contents GP-PWM-10-SQ

Owner s Manual. Contents GP-PWM-10-SQ Owner s Manual Contents 1.0 Installation Overview... 2 2.0 Warnings... 2 3.0 Choosing a Location... 3 4.0 Installation Instructions... 3 5.0 Operating Instructions... 4 6.0 Frequently Asked Questions (FAQs)...

More information

Engine coolant. Introduction WARNING

Engine coolant. Introduction WARNING Engine coolant Introduction In this section you ll find information about: Warning light and engine coolant temperature gauge Engine coolant specifications Checking engine coolant level and topping off

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

NeverDie Battery Management System Section 1: Overview

NeverDie Battery Management System Section 1: Overview Section 1: Overview PURPOSE: A Battery Management System or BMS Protects the Battery From Being Damaged by External Sources A BMS Protects the User and the External Sources from a Failed Battery A BMS-Based

More information

EC500 Power Control System

EC500 Power Control System EC500 Power Control System 1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in sections 3 to 6 or in the

More information

PS Bedienungsanleitung. Symbole 3. D PowerStarter 7. GB PowerStarter 15. E PowerStarter 23. F PowerStarter 31.

PS Bedienungsanleitung. Symbole 3. D PowerStarter 7. GB PowerStarter 15. E PowerStarter 23. F PowerStarter 31. Bedienungsanleitung Operating Instructions Instrucciones de servicio Instructions de service Istruzioni di d uso Bedieningshandleiding Betjeningsvejledning Bruksanvisning Bruksanvisning Käyttöohje Symbole

More information

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4 USER S MANUAL ON-LINE 1K/2K/3KVA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. UPS OPERATION...... 12 6. TROUBLE

More information

PILOT S GUIDE. for the XXX Series Electric Attitude Indicator with Battery Backup

PILOT S GUIDE. for the XXX Series Electric Attitude Indicator with Battery Backup PILOT S GUIDE for the 4300-XXX Series Electric Attitude Indicator with Battery Backup Mid-Continent Instruments and Avionics 9400 E. 34 th Street N., Wichita, KS 67226 USA Phone 316-630-0101 Fax 316-630-0723

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information