The relative site locations are detailed below with the main headquarters circled in blue and the new Fiji Airways Aviation Academy in green.
|
|
- Benedict Cross
- 6 years ago
- Views:
Transcription
1 Page 1 of 8 This is NOT the Expression of Interest Application Form. The Expression of Interest Application Form is a separate document. This information document is provided such that interested firms may understand the possible scope of works and the associated opportunity. PROJECT BACKGROUND Fiji Airways as Fiji s national airline are based at Nadi International Airport. Fiji Airways wish to reduce their carbon footprint and their electrical costs through the installation of solar arrays on the available sites and buildings both within their Nadi headquarters and hanger complex and the new Fiji Aviation Academy building which is to be constructed in Namaka, Nadi. The relative site locations are detailed below with the main headquarters circled in blue and the new Fiji Airways Aviation Academy in green. Both sites are adjacent the airport and located within 1 kilometre of Nadi Bay. Installations therefore need to be mindful of the marine exposure of the site.
2 Page 2 of 8 EXISTING FACILITIES: NADI HEADQUARTERS The existing Nadi Headquarters and Hanger provides a large area and site for a roof mounted Solar PV installation. MAIN BUILDING The main hanger has three separate roofs with main hanger roof having lower roofs to the western and northern sides.
3 Page 3 of 8 Extract of existing design drawing section showing the western lower level roof. Fig : Extract of Roof drawing of main Hanger
4 Page 4 of 8 Level 3 as a north facing roof having its roofing replaced with Trimdeck roof sheeting. The lower level 1 roof is subject to significant shading from the upper hanger roof in the morning. PUMP HOUSE
5 Page 5 of CUSTOMS BOND The customs bond building has a northern and south facing centrally pitched roof.
6 Page 6 of 8 EXISTING ELECTRICAL INSTALLATION The power supply to the premises is via 2 x 500kVA Fiji Electricity Authority (FEA) substation transformers connected in parallel. These transformers are housed within a substation building and located adjacent to the carpark area. There is a site main switchboard (SMSB) within the Hangar Building from which all loads are distributed. The mains power to the SMSB is currently backed up by 2 standby generators rated at 181Kva and 400kVA and the loads within the SMSB are separated by two essential Bus Bars with separate Automatic Transfer Switches (ATS) on each bus bar. The generator installation is to be upgraded to 1 MW in the next 12 months. All outgoing low voltage sub main cables to all electrical distribution boards are reticulated from this SMSB via perforated cable trays and cable ladders to all levels. The total forecast peak load 600 kva at the maximum compared to an installed capacity of 1000 kva. Average load is 277kVA based on logging results over two days.
7 Page 7 of 8 NEW FACILITIES: FIJI AVIATION ACADEMY The new Fiji Aviation Academy building is intended to incorporate solar arrays in its design. The below preliminary roof plan has the likely solar array panel locations nominated on the north facing roofs with each array area being approximately 250m2.. Preliminary roof plan : Fiji Aviation Academy. SCOPE OF WORKS: SOLAR INSTALLATION The work carried out shall comprise the design, supply, installation, testing, commissioning and defects liability and maintenance of the proposed Solar PV installations located at the sites as previously nominated. The respondent shall be responsible for submitting all technical information for their proposed panels, inverters, protection relay, controls system, structural supports and accessories as part of their proposal submission. The documents show the general intent and do not show all equipment and scope required to complete the works.
8 Page 8 of 8 The work includes but is not limited to the following main elements: Liaison with FEA, Fiji Airways, Airports Fiji Limited and CAAF for the proposed Solar PV installation including pre-approval. Temporary builder s power. Installation of PV panel, inverters, protection relay, control system and all accessories for a fully functioning grid system. Switchboard upgrades, alterations and additions to cater for the Solar PV installations. New metering to cater for Solar PV installation. Cables, installation and termination. Cabling and cable support systems. Roof penetrations and decktite seals on roof penetrations. Earthing. Accessories and appliances. Equipment supports and bracing. Liaison with other trades. Maintenance Manuals. As-Installed Drawings. Training. Maintenance during 12 months defects liability period. Safe Roof access systems for Maintenance Purposes where panels are installed within 3 m of roof edges. The above scope is preliminary and subject to development and change by Fiji Airways. The delivery methodology is as a Supply delivery and training (and potentially operate) solution incorporating the following hold points: 1. Proposal submission 2. Proposal approval 3. Design submissions and preapproval phase. 4. Technical compliance review 5. Site delivery 6. Site acceptance testing 7. Training 8. Acceptance/Handover 9. Operations and Maintenance phase. Proposals from respondents are expected to include the following ownership options: Capital procurement and outright ownership by Fiji Airways. Lease costs per annum. Purchase of power supplied per kw/hr.
Major Customer Connections. Preliminary Enquiry Form Embedded Generation > 30 kw
Major Customer Connections Preliminary Enquiry Form Embedded Generation > 30 kw MARCH 2018 Privacy Notice Ergon Energy is collecting information (including personal information) on this form for the purposes
More informationAPPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION
APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION Work Order No: File Reference: 16/2/1 This application form for the connection of small scale embedded generation is for small
More informationList of exemptions from compliance with the Technical Rules granted by Western Power after 1 July 2007
to: details Version: 2007 Technical Rules 1 16-Jan-08 2 16-Jan-08 3 29-Jan-08 Neerabup (two generating units - Units G11 and G12) Neerabup (two generating units - Units G11 and G12) Bluewaters Power Station
More informationFund and 2015 revenue bonds Est. State and Local Taxes: $2,810,000
PORT OF SEATTLE MEMORANDUM COMMISSION AGENDA Item No. 6b ACTION ITEM Date of Meeting August 4, 2015 DATE: TO: FROM: Dave Soike, Director, Aviation Facilities and Capital Programs Wayne Grotheer, Director,
More informationGeneration Interconnection Facilities Study For
Generation Interconnection Facilities Study For Prepared for: Prepared by: SCE&G Transmission Planning May 27, 2015 TABLE OF CONTENTS General Discussion... Page 3 Generator Interconnection Specifications...
More informationINTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY
INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY Table of Contents Chapter 1. Purpose and scope. Pg 3 Chapter 2. Application
More informationTENDER DOCUMENT PART-II
1 NATIONAL BANK FOR AGRICULTURE AND RURAL DEVELOPMENT TAMILNADU REGIONAL OFFICE TENDER DOCUMENT PART-II (PRICE BID) Supply, Installation, Testing and Commissioning of 25 kva DG Sets with Acoustic Enclosure
More informationOFF GRID SOLAR PV SYSTEMS
OFF GRID SOLAR PV SYSTEMS e n l i g h t e n i n g h o r i z o n s We thank you very much for your enquiry for OFF GRID Solar PV system and we are pleased to furnish our most competitive offer for the supply
More informationAirports Going SOLAR! Michael Shonka
Airports Going SOLAR! Michael Shonka www.solaromaha.com 402-590-5900 Agenda Why Go SOLAR Solar System Components System Design Long-term Impacts SGHAT - Forge Solar Why Airports Go SOLAR? FREE and abundant
More informationPhone: Website: CAPABILITY STATEMENT. Energy Efficiency & Sustainability Engineers
Phone: 1300 969 471 Website: www.gemenergy.com.au 2017 CAPABILITY STATEMENT Energy Efficiency & Sustainability Engineers COMPANY PROFILE Professionals in renewable energy consultancy, photovoltaic engineering,
More information40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power
40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power WHO SHOULD FILE THIS APPLICATION: Anyone expressing interest to install generation which will interconnect
More informationSTREAMLINED SOLAR CHECKLIST Owner Name:
STREAMLINED SOLAR CHECKLIST Owner Name: Address: DEPARTMENT OF PUBLIC WORKS AND PLANNING ALAN WEAVER, DIRECTOR This checklist must be completed by the contractor or an authorized agent of the contractor
More informationInterconnection System Impact Study Report Request # GI
Executive Summary Interconnection System Impact Study Report Request # GI-2008-23 34 MW Solar Generation Ranch at Hartsel, Colorado Public Service Company of Colorado Transmission Planning August 19, 2010
More informationRULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)
- (SMUD FORM 2655) A. Applicability: This Generating Facility Interconnection Application (Application) shall be used to request the interconnection of a Generating Facility to Sacramento Municipal Utility
More informationInterconnection Process for Generation Systems
Interconnection Process for Generation Systems I. INTRODUCTION...1 II. GENERAL INFORMATION...2 A. Definitions...2 B. Nodak Electric Cooperative, Inc. Generation Interconnection Contacts...3 C. Engineering
More informationSchneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant
Schneider Electric PV Skid Optimized solar power conversion system tailored to enhance any North American PV power plant 1 PV Skid solution Integrated solution designed for optimal performance in any environment
More informationSolar PV Projects PPA Model
Solar PV Projects PPA Model We help you set up 'Grid Connected Solar PV Power Plants' of the size ranging from 50 kw to MW scale power projects under the PPA (Power Purchase Agreement) Model. How does
More informationBU Power Conversion, 03/2013 ABB solar inverters Product portfolio. ABB Group June 19, 2013 Slide 1
BU Power Conversion, 03/2013 ABB solar inverters Product portfolio June 19, 2013 Slide 1 PV application ABB solar inverters - product portfolio Solar inverter offering Power plants Commercial and industrial
More informationENERGY STORAGE FOR THE EDGE OF THE GRID
ENERGY STORAGE FOR THE EDGE OF THE GRID DSS BEHIND-THE-METER SIMPLE DIAGRAM DSS Simplified Behind-the-Meter Diagram GRID HVAC BATTERY 85 kwh 1-6 BATTERY BAYS BATTERY 85 kwh AEROS CONTROLS System Communica
More information100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT DETAILED PROJECT REPORT AERO SPACE MATERIALS PVT LTD
EXECUTIVE SUMMARY 100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT 1. Location i) State : TAMIL NADU, ii) Locality : KOVILPALAYAM, POLLACHI iii) Latitude : 10 45 16.22 N iv) Longitude : 77 01 15.27 E
More informationShould I Get a Solar Array for my House? The Regulations, Available Equipment, and Benefits Steven Johnson
Should I Get a Solar Array for my House? The Regulations, Available Equipment, and Benefits Steven Johnson 1 Scope Explore the considerations in the decision to install a PV System on my house Limited
More informationSPN High Value Project PO Route. RIIO-ED1 Investment Justification Reinforcement for PO Route Network: SPN
SPN High Value Project PO Route RIIO-ED1 Investment Justification Reinforcement for PO Route Network: SPN Document History Version Date Details Originator V0.1 20/06/2013 Initial version Chris Winch V0.2
More information100 MW Wind Generation Project
A subsidiary of Pinnacle West Capital Corporation 100 MW Wind Generation Project CUSTOMER FINAL Feasibility Study Results By Transmission Planning, APS December 21, 2007 Executive Summary This Feasibility
More informationEnquiry Form (Non-Registered Generator With Capacity less than 5 MW)
Connection Applicant (Embedded Generating Unit Owner/Proponent) Business name: ABN: Contact name: Address: Telephone number: E-mail address: Connection Applicant acting and working on behalf of the above
More informationPID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation
PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation Prepared by: Entergy Services, Inc. T & D Planning L-ENT-17A 639 Loyola Avenue New Orleans, LA 70113 Rev Issue Date
More informationSolar Photovoltaic (PV) Design Considerations & Issues. By Paul M. Williams, President & CEO
Solar Photovoltaic (PV) Design Considerations & Issues By Paul M. Williams, President & CEO NEC Article 690 Solar Photovoltaic (PV) Systems The article consists of eight chapters. Chapters 2 through 4
More information15 Nelson-Marlborough Regional Plan
15 Nelson-Marlborough Regional Plan 15.1 Regional overview 15.2 Nelson-Marlborough transmission system 15.3 Nelson-Marlborough demand 15.4 Nelson-Marlborough generation 15.5 Nelson-Marlborough significant
More informationSolar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings
Your City logo here Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems
More informationSolar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings
PV TOOLKIT DOCUMENT #3 Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings SCOPE: Use this plan ONLY for utility-interactive central/string inverter systems
More informationAppendix 11 RETURN TO APPENDICES LIST. High Voltage Power Supply Upgrade (Welcon Technologies Pty Ltd)
Appendix 11 RETURN TO APPENDICES LIST High Voltage Power Supply Upgrade (Welcon Technologies Pty Ltd) GLADSTONE AREA WATERBOARD AWOONGA DAM HIGH VOLTAGE POWER SUPPLY UPGRADE Document: GJ543-RP-02B Submission
More informationNet Metering Program
Net Metering Program Chapter 1 Purpose and Scope. The purpose of this chapter is to establish rules for determining the terms and conditions governing the interconnection of electric generation facilities
More information* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction
Backup The Powerwall may be used to provide backup power to a home or small business. The backup function can be tied to solar for multiple charge/recharge cycles during the outage, or offered as stand-alone,
More informationCompact Energy Storage Module. Modular Systems, EPDS. Product overview
Compact Energy Storage Module Modular Systems, EPDS Product overview ABB Power Products in energy storage Portfolio coverage Stationary Application Focus ESM Load leveling Spinning reserve ESM Behind-the-meter
More informationInformation Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program
Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program As part of our commitment to support renewable energy, Kissimmee Utility Authority
More informationNet +Plus Connection Code
Net +Plus Connection Code LANKA ELECTRICITY COMPANY (PRIVATE) LIMITED 1.0 BACKGROUND The existing Net Metering Concept launched in the year 2010 noticed an exponential growth in the recent year and at
More information15 Nelson-Marlborough Regional Plan
15 Nelson-Marlborough Regional Plan 15.1 Regional overview 15.2 Nelson-Marlborough transmission system 15.3 Nelson-Marlborough demand 15.4 Nelson-Marlborough generation 15.5 Nelson-Marlborough significant
More informationBuilding the Business Case for Energy Storage
Building the Business Case for Energy Storage A viable and economical alternative power supply solution Unrestricted Siemens AG 2015 All Rights Reserved. March 2015 Siemens.en/siestorage Seconds Minutes
More informationSolar PV General Introduction Guide for Electricians
Solar PV General Introduction Guide for Electricians Important Note: This guide was written to provide a broad guidance for electricians that would like to expand their product knowledge and skills for
More informationPJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008
PJM enerator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study 504744 September 2008 PJM Interconnection 2008. All rights reserved R60 Robison Park-Convoy 345kV Impact Study eneral
More informationMerger of the generator interconnection processes of Valley Electric and the ISO;
California Independent System Operator Corporation Memorandum To: ISO Board of Governors From: Karen Edson Vice President, Policy & Client Services Date: August 18, 2011 Re: Decision on Valley Electric
More informationExample 1MW Solar System for Fosters Yatala
Example 1MW Solar System for Fosters Yatala Document Created by Luke M Hardy lmhardy@smartconsult.com.au Smartcom P/L 31 December 2012 Highlights Luke M Hardy MBA, Grad Cert Carbon Management Key Points
More informationHealth & Safety Issues Associated with Solar Photovoltaic (PV)
Health & Safety Issues Associated with Solar Photovoltaic (PV) Presented To: Presented By: MOEMA ASM Michigan Occupational Health Conference Detroit, MI October 18, 2014 Thomas W. Neelands, CEM Sr. Project
More informationTechnical Standard - TS 129. Small Inverter Energy Systems (IES) - Capacity not exceeding 30kW. SA Power Networks. Published: November 2017
TS 130: Inverter Energy Systems (IES) - capacity up to or equal to 200 kw Technical Standard - TS 129 Small Inverter Energy Systems (IES) - Capacity not exceeding 30kW Published: November 2017 SA Power
More informationReasonableness Test RT 015 /11 Salisbury Substation 11kV Feeders
Reasonableness Test RT 015 /11 Salisbury Substation 11kV Feeders Reasonableness Test: Salisbury Substation 11kV Feeders DISCLAIMER The purpose of this document is to inform customers, Interested Parties,
More informationHorns Rev 3 & Kriegers Flak Platform Interfaces
Horns Rev 3 & Kriegers Flak Platform Interfaces Technical Dialog Meeting 10 September 2013 HR3 and Krigers Flak - AC platforms Technical Dialog Meeting 10 September 2013 1 Agenda 1. Location of platforms
More informationSUBSIDY SCHEME FOR GRID CONNCTED AND OFF GRID SOLAR SYSTEMS AT IOCL PETROL PUMPS
SUBSIDY SCHEME FOR GRID CONNCTED AND OFF GRID SOLAR SYSTEMS AT IOCL PETROL PUMPS FIRSTGREEN CONSULTING PVT LTD MA, 74, DLF Phase III Gurgaon 122002 info@firstgreen.co +91-124-6450224 1. ABOUT THE PROGRAM
More informationSection 6 - Employer s Requirements
Section 6 - Employer s Requirements 6-1 Section 6 - Employer s Requirements This Section contains the Specifications, the Drawings, Supplementary Information that describe the Works to be procured, Personnel
More informationREQUEST FOR PROPOSALS FOR THE ESTABLISHMENT OF SOLAR PV POWER PLANT ON BUILD, OWN AND OPERATE BASIS. International Competitive Bidding (ICB)
REQUEST FOR PROPOSALS FOR THE ESTABLISHMENT OF SOLAR PV POWER PLANT ON BUILD, OWN AND OPERATE BASIS International Competitive Bidding (ICB) Polonnaruwa Solar PV Power Project (10 MWp) Tender No: CEB/EPT/SP/RFP1
More informationPhotovoltaic Solar Plan Review
PAIGE B. VAUGHAN, CBO Director of Building and Safety Phone (310) 605-5509 Fax Line (310) 605-5598 E-mail:lbutler@comptoncity.org Building & Safety Department Photovoltaic Solar Plan Review Plan Check
More information2016 Photovoltaic Solar System Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE
More informationTERMS AND CONDITIONS
XXV. NET METERING A. Applicability and Availability 1. The terms Net Metering Service, Demand Charge-based Time-of- Use Tariff, Net Metering Customer, Customer, Time-of-Use Customer, Time-of-Use Tier,
More informationSolar*Rewards Frequently asked questions system size and customer usage
Solar*Rewards 1. Will a PV system work with my home? 2. Am I eligible to participate in the Solar*Rewards program? 3. What size system should I get? 4. Can a customer at a service location apply for the
More information24. SOLAR INCENTIVE PROGRAM II
24. SOLAR INCENTIVE PROGRAM II A. General California Senate Bill 1 requires publicly owned utilities that sell electricity at the retail level, to adopt, implement, and fund a solar incentive program for
More informationGrasshopper Vision. Accelerate the adoption of sustainable practices by creating accessible and affordable products for everyone.
Meeting Objective 1. Who are we? 2. Review Commercial Solar Industry 3. Who are the ideal candidates for solar? 4. Key Site Conditions 5. Typical Upfront and On-going Costs Grasshopper Vision Accelerate
More informationGenerator Interconnection System Impact Study For
Generator Interconnection System Impact Study For Prepared for: January 15, 2015 Prepared by: SCE&G Transmission Planning Table of Contents General Discussion... Page 3 I. Generator Interconnection Specifications...
More informationEnergy Security Electrical Islanding Approach and Assessment Tools. Dr. Bill Kramer Senior Research Engineer Distributed Energy Systems Integration
Energy Security Electrical Islanding Approach and Assessment Tools Dr. Bill Kramer Senior Research Engineer Distributed Energy Systems Integration Dr. Bill Kramer - 2 Electricity, Resources, & Building
More informationRenewable Energy & Storage Best Practice at TPL and Issues Faced. Murray Sheerin Power Generation Manager, Tonga Power Limited.
Renewable Energy & Storage Best Practice at TPL and Issues Faced. Murray Sheerin Power Generation Manager, Tonga Power Limited. Tonga Power Limited Tonga Power Limited (TPL) is a 100% state owned enterprise
More informationNew Jersey State Report
New Jersey State Report July 2017 Table of Contents 1. Planning Generation Portfolio Analysis Transmission Analysis Load Forecast 2. Markets Capacity Market Results Market Analysis 3. Operations Emissions
More informationTraining Course on Design, Installation of MW Scale Solar PV Systems & Commissioning concepts
Training Course on Design, Installation of MW Scale Solar PV Systems & Commissioning concepts Course Description: This course is designed To provide the participants with basic understanding of Solar Photovoltaic
More informationThis is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
More information17 th Annual Caribbean Energy Conference
17 th Annual Caribbean Energy Conference Santo Domingo Jan 26-27 th 2017 Multi-site Solar Project By Clive Hosten Chief Engineer Introduction Grenada Spice Isle situated Lat12 N, Long 61 W, area of 133
More informationMinistry of New and Renewable Energy. Jawaharlal Nehru National Solar Mission (Off-grid and Decentralized Solar Applications)
Ministry of New and Renewable Energy Jawaharlal Nehru National Solar Mission (Off-grid and Decentralized Solar Applications) Format for Submitting Project Proposals for installing Standalone SPV power
More informationGuideline on Energy Storage
Purpose Commonwealth of Massachusetts Executive Office of Energy and Environmental Affairs DEPARTMENT OF ENERGY RESOURCES SOLAR MASSACHUSETTS RENEWABLE TARGET PROGRAM (225 CMR 20.00) GUIDELINE Guideline
More informationBulletin Wiring methods for Solar Photovoltaic Systems Rules, 2-034, , and , Tables 11 and 19
Bulletin 50-4-4 Wiring methods for Solar Photovoltaic Systems Rules, 2-034, 50-014, 50-018 and 50-020, Tables 11 and 19 Scope (1) Introduction (2) New cable types RPV & RPVU (3) Wiring methods within photovoltaic
More informationEmerald Reactive Support Alternative Solution Expressions of interest
Emerald Reactive Support Alternative Solution Expressions of interest Publishing Date 21/02/2017 Closing Date 21/03/2017 1. Executive Summary Ergon Energy Corporation Limited (EECL) is seeking expressions
More informationCity of Manhattan Beach Community Development
City of Manhattan Beach Community Development Phone: (310) 802-5500 FAX: (310) 802-5501 TDD: (310) 546-3501 Photovoltaic Solar Panel Plan Check Guidelines Updated: 12-20-16 ORDINANCE NO. 15-0022 MBMC 9.06
More informationASP General Information
ASP General Information Metering and Connection Policy Alert Number: GI34_16 Subject: NSW Solar Bonus Scheme Net Conversions 23 November 2016 Background The NSW Solar Bonus Scheme (SBS) payments will cease
More informationLot 26 WBS 1150 Bill of Quantities
UNITED NATIONS DEVELOPMENT PROGRAMME ITB 2016-196 Lot 26 WBS 1150 Bill of Quantities Programme Title: Right to Education in the Gaza Strip Project name: Extension and Rehabilitation Works For The Governmental
More informationABB solar inverters Product portfolio
BU LV Drives, 05/2012 ABB solar inverters Product portfolio April 10, 2013 Slide 1 Solar inverter offering Remote monitoring portal Solar inverter PC tools (sizing and product selection) April 10, 2013
More informationMAKING SOLAR SYSTEMS SMARTER PANEL TO GRID SOLUTIONS FROM A GLOBAL LEADER IN SOLAR TECHNOLOGY
MAKING SOLAR SYSTEMS SMARTER PANEL TO GRID SOLUTIONS FROM A GLOBAL LEADER IN SOLAR TECHNOLOGY LOOKING FOR GREAT REASONS TO GO SOLAR? It will save you money... Power your home with solar energy to reduce
More informationContents. 1 Introduction. 2. Advisory and Information Systems. 3. Supply. 3.1 Quality of Electric Supply. 3.2 Interference with other Customers
DISTRIBUTION CODE Contents 1 Introduction 2. Advisory and Information Systems 3. Supply 3.1 Quality of Electric Supply 3.2 Interference with other Customers 3.3 Application for the Supply of Electricity
More informationAfrica Australia Technology & Infrastructure Conference. John Davidson Executive Director Carnegie Clean Energy
Africa Australia Technology & Infrastructure Conference John Davidson Executive Director Carnegie Clean Energy DISCLAIMER The information contained herein has been prepared solely for informational purposes
More informationMaryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)
Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less) Interconnection Customer Contact Information Name: Address: City: Telephone (aytime):
More informationYour Needs. Our Technology.
Your Needs. Our Technology. Renewable Energy Solutions for Businesses Nationwide As a division of Ellies Electronics (Pty) Ltd, Ellies Commercial Solutions offers innovative solar solutions for any business
More informationForecast Life-Cycle Cost of solar PV Electrity (LCOE) (RM/ KWhr) VS Future Cost of Electricity from Fossil Fuel (RM/ KWhr)
Forecast Life-Cycle Cost of solar PV Electrity (LCOE) (RM/ KWhr) VS Future Cost of Electricity from Fossil Fuel (RM/ KWhr) PV Scenarios for Residential ( 5% Nominal Discount Rate) Year Capital Cost (RM/
More informationRenewable Energy Integration: Wind, Solar and Energy Storage
Renewable Energy Integration: Wind, Solar and Energy Storage ReGen Powertech Archit Khemka Technology Overview: Wind Solar Hybrid with Energy Storage Concepts Co-located System Two largely independent
More informationPLANNING, ELIGIBILITY FOR CONNECTION AND CONNECTION PROCEDURE IN EMBEDDED GENERATION
PLANNING, ELIGIBILITY FOR CONNECTION AND CONNECTION PROCEDURE IN EMBEDDED GENERATION Presentation by Engr. O. C. Akamnnonu Chief Executive Officer, Ikeja Electricity Distribution Company AGENDA WORK THROUGH
More informationGet ready for rising energy challenges. This is where xstorage Home can help
xstorage Home Get ready for rising energy challenges More and more people, factories, businesses connect to the grid around the world. How can you be sure there will still be power for you and your family
More informationGRID CONNECTED 400kWp SOLAR ROOF TOP POWER PLANT NET METERING AT KARNATAKA STATE CRICKET ASSOCIATION M. CHINNASWAMY STADIUM, BENGALURU
MGIRED Journal Volume 2(1) : 125-128 ISSN 2393-9605 GRID CONNECTED 400kWp SOLAR ROOF TOP POWER PLANT NET METERING AT KARNATAKA STATE CRICKET ASSOCIATION M. CHINNASWAMY STADIUM, BENGALURU Punati Sridhar,
More informationMILLIGAN SOLAR PROJECT
February 16, 2009 Page 1 of 18 A subsidiary of Pinnacle West Capital Corporation MILLIGAN SOLAR PROJECT FINAL Feasibility Study Report APS Contract 52115 Prepared by: Arizona Public Service Company Transmission
More informationStand-alone Power System (SPS) CASE STUDY APPLICATION PACK
Stand-alone Power System (SPS) CASE STUDY APPLICATION PACK A case study is a representation of your Best Work so please pay particular attention to the quality of your installation. Are you using Best
More informationANNEX B TERMS OF REFERENCE FOR THE DESIGN OF A LOW VOLTAGE POWER NETWORK FOR IMS STATIONS IN WARRAMUNGA, AUSTRALIA
ANNEX B TERMS OF REFERENCE FOR THE DESIGN OF A LOW VOLTAGE POWER NETWORK FOR IMS STATIONS IN WARRAMUNGA, AUSTRALIA Page 1 of 9 Table of Contents 1 Introduction... 3 2 Background... 3 3 Work Tasks... 3
More informationAPPLICATION ELECTRICITY SERVICES. APPLICATION FOR THE CONNECTION OF SMALL SCALE EMBEDDED GENERATION Page 1
APPENDIX 2B APPLICATION ELECTRICITY SERVICES APPLICATION FOR THE CONNECTION OF SMALL SCALE EMBEDDED GENERATION Page 1 This application form for the connection of small scale embedded generation is for
More informationUmatilla Electric Cooperative Net Metering Rules
Umatilla Electric Cooperative Net Metering Rules Version: July 2017 Umatilla Electric Cooperative NET METERING RULES Rule 0005 Scope and Applicability of Net Metering Facility Rules (1) Rule 0010 through
More informationKENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO
BILL 1 MAINS POWER DISTRIBUTION 2-1 ITEM DESCRIPTION QTY UNIT RATE AMOUNT Supply, install, test, commission and set to work the following:- 1.01 Free-standing purpose made front access sub main switchboard
More informationANNEXURE-I CHECK LIST FOR APPLICATION FORM
ANNEXURE-I CHECK LIST FOR APPLICATION FORM S.No. DOCUMENTS REQUIRED SUBMITTED 1 Application Form must be signed by Registered Consumer on each page with stamp 2 Occupancy Proof along with roof rights (Registered
More informationSolar Farm Electrical Control Buildings & Substation Build Project
Brock s Solar Farm Electrical Control Buildings & Substation Build Project PROJECT PROFILE Canadian Solar Inc. Recognized as a leading global solar manufacturer, Canadian Solar Inc. delivers high-efficiency
More informationMicrogrids for industrial applications. ABB Group June 22, 2016 Slide 1
June 2016; Pablo Astorga, Head of Sales Microgrids Microgrids for industrial applications Group June 22, 2016 Slide 1 Microgrid segments and main drivers Covering a diverse range of applications Main drivers
More informationPika Energy Island Made in America
Pika Energy Island Solar plus storage, clean and simple. designed in Maine Made in America control solar, batteries and local loads with one inverter The Pika Energy Island Optimized Solar Battery Inverter
More informationContents. Solar Select TM Frequently Asked Questions
Solar Select TM Frequently Asked Questions Contents Program Overview and How Solar Select Works... 1 Participation Requirements... 3 Cost and Payment... 4 Solar Production... 5 Development, Equipment,
More informationGuidelines for connection of generators:
Guidelines for connection of generators: Greater than 30 kva, and not greater than 10 MW, to the Western Power distribution network January, 2017. EDM 32419002 / DM 13529244 Page 1 of 14 Contents 1 INTRODUCTION...
More informationEnergy Savings through Solar Energy for Municipalities
Energy Savings through Solar Energy for Municipalities May 2015 2014 Sunvestment Group www.sunvestmentgroup.com Solar Market Growth U.S. US Capacity and Generation: Solar Source: National Renewable Energy
More informationStorage guidance & codes. Martin Cotterell
Storage guidance & codes Martin Cotterell NSC 2015 Part of the BRE Trust Battery storage guide NSC project - WIP Target audience: A) End users: Benefits of energy storage systems Financial payback Pros
More informationCity Power Johannesburg: Response to Potential Load Shedding. Presented by : Stuart Webb General Manager : PCM October 2014
City Power Johannesburg: Response to Potential Load Shedding Presented by : Stuart Webb General Manager : PCM October 2014 Topics to be discussed Background Challenges Options Available Summary 2 Background
More informationPower Conversion System for ESS 100 kw to 30 MW Bi-directional Inverters
Power Conversion System for ESS 100 kw to 30 MW Bi-directional Inverters Energy Storage Solutions Power Conversion Systems With more than 125 years experience in power engineering and over a decade of
More informationJEA Distributed Generation Policy Effective April 1, 2018
Summary This JEA Distributed Generation Policy is intended to facilitate generation from customer-owned renewable and non-renewable energy generation systems interconnecting to the JEA electric grid. The
More informationCorporate Brochure. June 2016
Corporate Brochure June 2016 Background SolarCast (Parent) founded August 2012 Solar-Tec spun off as a division of SolarCast in 2014 Focus on Commercial, Industrial, Institutional, Non-Profit, Community
More informationHawk Asgeirsson Manager Power Systems Technologies DTE Energy
Hawk Asgeirsson Manager Power Systems Technologies DTE Energy Agenda Energy Storage & Renewable DTE Energy Background PV and Energy Storage 500 kw PV + 500 KW Battery 500 kw PV + 750 kw Battery Community
More informationM E T R O P O L I T A N W A S H I N G T O N A I R P O R T S A U T H O R I T Y
Report to the Board of Directors Recommendation to Establish Airport Concessions Disadvantaged Business Enterprise Program Goals for Fiscal Years 2012-2014 This is a formal action item that requires Committee
More informationBrion Energy Corporation
Decision 20907-D01-2015 MacKay River Commercial Project October 29, 2015 Alberta Utilities Commission Decision 20907-D01-2015 MacKay River Commercial Project Proceeding 20907 Application 20907-A001 October
More information