Commercial Water Treatment Catalog

Size: px
Start display at page:

Download "Commercial Water Treatment Catalog"

Transcription

1 Commercial Water Treatment Catalog 2017 Form # NP Rev F. Effective: 05/01/

2 We know water. With a wide range of technologies we ve pioneered to meet a variety of commercial water treatment applications and decades of expertise dealing with the most challenging water problems, look no further than EcoWater to be your preferred solutions provider. Since 1925, EcoWater has been a leading manufacturer of innovative water treatment systems, consistently offering its customers advanced, state-of-the-art technology, high quality and environmentally sound solutions. We continually invest in research and development to provide you with the best products on the market. Our commitment to innovation, service and providing clean water has made EcoWater one of the largest water treatment equipment manufacturers in the world today. EcoWater Systems is a member of The Marmon Group, a subsidiary of Berkshire Hathway Inc. and an international company consisting of more than 175 autonomous manufacturing and service organizations. We re also a member of the Water Quality Association (WQA), a not-for-profit international trade association representing the residential, commercial and industrial water treatment industry. We have the expertise to diagnose your application and provide a customized solution to your specific water treatment needs in North America and around the world. With nearly 100 years of combined commercial water treatment expertise, our commercial sales support team can help you find the proper solution. Ron Butler Bob Duitsman Steve Hamann Damon Seheult Lonny Zillmer Contact us at eci@ecowater.com or today with your commercial application questions and quote requests. We welcome the opportunity to work with you! Catalog NP Rev. F (05/17) Effective 05/01/17 ii

3 Product Categories Terms and Conditions... iv Returns...iv Softeners Our innovative water softeners provide soft water to lower water heating costs, minimize equipment wear, and reduce soap and chemical use. Fleck Top Mount Fiberglass Softeners... Section 1 Fleck Epoxy Lined Steel Softeners... Section 2 Plastic Valve Nest Fiberglass Softeners 18 thru Section 3 Plastic Valve Nest Epoxy Lined Steel Softeners 18 thru Section 4 Filters Our filtration systems provide a variety of options for chlorine, taste and odor removal as well as protection against sediment and other contaminants. Fleck Top Mount Fiberglass Filters... Section 5 Fleck Epoxy Lined Steel Filters... Section 6 Plastic Valve Nest Epoxy Lined Steel Filters 18 thru Section 7 Reverse Osmosis Systems Choose from a selection of reverse osmosis system configurations for optimal boiler feed water, contaminant reduction, improved taste and clarity, and spot-free rinsing. Reverse Osmosis Systems and Components... Section 8 Dealkalizers Our dealkalizers reduce unwanted anions in the water supply to help decrease cycles of concentration in boilers. Fleck Fiberglass Chloride Dealkalizers... Section 9 Deionizers Our dionization systems provide high quality process water for manufacturing consistency. Deionizer Systems Two Bed, Mixed Bed, Regeneration Plants and Jumbo Exchange s... Section 10 iii Catalog NP Rev. F (05/17) Effective 05/01/17

4 TERMS AND CONDITIONS OF SALE ORDER ACCEPTANCE: EcoWater Systems LLC reserves the right to accept or reject an order request. Possession of a price sheet or a product catalog shall not be construed as an offer to sell the product listed. EcoWater Systems LLC sells wholesale only and does not sell to end-users. These terms and conditions shall be considered a part of all accepted orders and accepted purchase orders. Minimum order is $ A handling fee of $20.00 will be added to orders that total less than $ CANCELLATION OR CHANGE ORDER: Orders are processed as they are received. Once order is in process (or production), add-ons (or change orders) may hold up shipment of the original order (or build), or may be shipped as a separate order. Buyer s add-ons (change orders) are subject to EcoWater Systems LLC acceptance. Cancellations are subject to EcoWater Systems LLC acceptance and may incur a restocking fee (see Returns Notice). Custom equipment orders that are cancelled may incur additional charges beyond the restock fee. CUSTOM EQUIPMENT: Custom equipment is subject to the terms and conditions detailed on the separate quote form and may require a down payment. PRICES: Products are sold at prices currently in effect at time of order, and are F.O.B. shipping point (Ex Works shipping point for international orders). Prices generally coincide with dated EcoWater Systems LLC printed price sheets and web site information. However, we reserve the right to change prices at anytime and without notice and without updating published material at our web site or in print. The customer is responsible for all freight charges. (See Shipping Charges). DELIVERY: Stock items distributed by EcoWater Systems LLC are generally shipped within 5 to 10 working days after receipt of the order. Additional time is required on Special orders, Large Orders, or Items Not Stocked. Out of stock items are back ordered and shipped when received. EcoWater Systems LLC is not responsible for delays due to conditions beyond our control. Orders will be delayed or not processed where accounts are found delinquent and no arrangements have been made with Credit Department to settle account. (See Billing and General Open Accounts.) RIGHT OF TITLE of purchased goods does not transfer from seller to buyer until payment of monies in full is received by EcoWater Systems LLC. Responsibility for goods is the buyer s upon shipment. SHIPPING CHARGES: All shipments are F.O.B shipping point, and shipping costs are the customer s responsibility. Most items are shipped via UPS, FedEx, common carrier, or freight collect. Prepaid Freight shipments will be billed to the buyer with a 20% handling charge applied. Hazardous materials may require additional freight charges. BILLING: Orders are C.I.A. or payment with order, unless a General Open Account has been established and is in good standing or other type of payment is arranged, such as with Visa, MasterCard, American Express, Cashier s Check, or check with Telcheck approval. All amounts invoiced are due. Customer must report any disputed amount on invoice in writing within 10 days of invoice. Pending adjustment, the amount invoiced, less disputed amount remains due and must be paid within terms. (See open Account.) OPEN ACCOUNT: To establish an open account, a complete credit analysis is required. This involves correspondence with you, your suppliers, and your bank. The time involved depends on the response time from the references you give us. You will be notified when your credit is approved. In the interim, all orders must be shipped COD or via payments described above. (See Billing.) Terms are net 30 days and will be subject to service charge of 1.5% per month on all past due amounts. DAMAGED MERCHANDISE: EcoWater Systems LLC is not responsible for damage or loss to a shipment by a freight carrier. Check shipments for damage before acceptance or note on freight bill Subject to inspection for concealed damage. Consignee is responsible for filing a claim with a freight carrier for any and all damage or loss. Return of Damaged Goods will not be authorized. ERRORS AND RETURN GOODS AUTHORIZATION: Merchandise cannot be returned without prior authorization. Call EcoWater Systems LLC for an RGA number. Freight/shipping must be prepaid. An RGM not used in 30 days will expire. A return after that will be refused and invoice will be payable within terms. Special order goods are not returnable. Additional conditions apply, see Returns Policy described, top of next text column. DEFECTIVE GOODS & WARRANTY PROCESSING: An item returned for warranty consideration without prior authorization will be refused. Call EcoWater Systems LLC for an RGM number. EcoWater Systems LLC and its manufacturers reserve the right to repair or replace defective merchandise. If pre-warranty replacement merchandise has been sent and the warranted goods are repairable, the repaired product will be returned to you at our expense and the pre-warranty invoice will be for your account. If the warranted product is not repairable, an offsetting credit invoice will be issued to your account. If the warranty consideration is denied, all expenses are for your account. RETURNS NOTICE: MERCHANDISE CANNOT BE RETURNED WITHOUT PRIOR AUTHORIZATION. SHIPMENTS NOT HAVING PRIOR APPROVAL WILL BE REFUSED. RETURN MEMO NUMBER MUST APPEAR ON ALL CARTONS. ALL FREIGHT MUST BE PREPAID AND THE FOLLOWING POLICY IS TO BE SATISFIED: Any shipment returned for credit when the error is not ours will be subject to a minimum of 25% restocking charge. Authorization number must be obtained within 30 days of invoice date and the returns received in our plant within thirty (30) days after that number is issued. Returned Goods Memos expire after thirty (30) days and goods arriving after that time will be refused and the original invoice will be payable in full. All returned goods must be new and unused. Multiple part assemblies must be returned complete. Custom machined, special orders, or customer-fabricated items cannot be returned. DAMAGE / LOSS CLAIMS We are WILLING TO ASSIST you in every possible manner in collecting claims for loss or damages, but this willingness on our part does not make us responsible for collection of claim or replacement of materials. Inspect and report within 5 days: A. VISIBLE DAMAGE 1) Have deliveryman note on the Freight Bill the nature and extent of damages. 2) Notify the transportation company s office to inspect the merchandise. 3) File claim for damages at once. B. CONCEALED DAMAGE 1) If damage is noticed when merchandise is unpacked, notify transportation company s office immediately and asked to have it inspected. 2) Do not destroy or discard any packages or packing until claim is settled. 3) Do not return damaged merchandise as transportation company will pick it up after settling claim. C. SHORTAGES 1) All shortages must be reported within five (5) days of receipt. 2) Check number of cartons or packages. Compare this total with total listed on Bill of Lading. Confirm that you have received all cartons of packages pertaining to this shipment. 3) If quantities do not tally, have deliveryman note shortage and if the missing cartons or packages do not show up in the next few days, advise us. 4) You must file a Freight Claim for shorted packages. D. SHIPPING ERRORS 1) All Shipping errors must be reported within five (5) days of receipt. CUSTOMERS OF EcoWater Systems, LLC HEREBY AGREE TO FOLLOWING TERMS OF PAYMENT THE PARTIES ACKNOWLEDGE BY SUBMITTING A CREDIT APPLICATION, GUARANTEEING PAYMENT OF ANY CREDIT ACCOUNT, OR BY ORDERING ANY PRODUCTS FROM COMPANY THAT ALL OBLIGATIONS AND RIGHTS PERTAINING TO THE SALE OF PRODUCTS OR EXTENSION OF CREDIT FOR THE SAME BEAR A REASONABLE RELATION TO THE STATE OF MINNESOTA, ARE PERFORMABLE IN THE STATE OF MINNESOTA, AND FURTHER AGREE AND ACKNOWLEDGE THAT THE LAWS OF THE STATE OF MINNESOTA WILL GOVERN THE RIGHTS AND DUTIES OF COMPANY AND THE CUSTOMER (SEE THE DETAILS). TERMS OF PAYMENT: Customer hereby agrees to pay all invoices when due according to customers assigned terms by the Company. Invoices are due and payable at Company s Lockbox at P. O. Box 91749, Chicago, IL Payment will be deemed made when actually received by Company. If Customer disputes any item invoiced, Customer shall within ten (10) days from the date of the invoice, notify Company of the terms disputed, specifying the reason thereof. Payment of the disputed items may be withheld until settlement of the dispute, but payment of any undisputed portion shall be made within its terms above set forth. Customer agrees that any invoice or the undisputed prorate part thereof not paid in accordance with its terms shall bear interest at 1.5% per month or the maximum rate permitted by law at the time payment becomes delinquent until paid. GOVERNING LAW and VENUE: This Agreement, and the rights and obligations of the parties hereunder, shall be construed and governed in accordance with laws of the state of Minnesota. Venue for any legal proceeding brought by either party under this Agreement shall be in Woodbury, Minnesota. Catalog NP Rev. F (05/17) Effective 05/01/17 iv

5 HOW TO USE THIS CATALOG This catalog replaces all previously published price schedules. Prices are associated by part number and equipment model. LIST PRICE In order to give every customer the best price according to their purchasing volume and account performance, we now publish LIST price only. According to your account status and previous purchasing profile, your account has been assigned a particular multiplier code. You would have been told your multiplier when you received this price book. Orders placed for your account automatically utilize the assigned multiplier when processed by Order Entry. SUBJECT TO CHANGE WITHOUT NOTICE If you have general questions regarding your current multiplier, please contact us at eci@ecowater.com. Your Customer Service Representative will respond without delay. Prices and multiplier assignments are subject to change without notice. PROVIDE COMPLETE ORDER INFORMATION Please provide us with your assigned Customer and have s, price list, or catalog in hand when ordering. Some equipment requires completed questionnaires/spec forms found in the catalog. Copy the form and retain the original blank for next use. numbers are required to process your order. When necessary, call for Technical Support prior to placing your order. QUOTATIONS We accept bid requests from qualified customers when accompanied with written specifications and drawings. We reserve the right to correct written errors or to note substitute brands for components. Prices quoted do not include taxes, freight, or crating charges unless so stated. Engineering consultation and/or time changes to prepare customer specifications or to revise customer drawings may be chargeable. Customers will be notified in advance of work if such charges will be accessed. PROFESSIONAL USE ONLY Water treatment equipment can be harmful if installed or used improperly. Use of installation of equipment and chemicals listed in our catalog require knowledge and experience of the trained water treatment professional. Do not order equipment or chemicals unless you have been certified in their installation and use. Certain licenses, permits, and supplemental training may be required to install or use certain equipment. In any case, read and follow manufacturer s warnings, instructions, and procedures carefully. If in doubt, do not activate equipment. Contact manufacturer, vendor or EcoWater Systems LLC for referral. Before using, the user must determine the suitability of the product for its intended application, and user assumes all risk in connection therewith. Neither EcoWater Systems LLC nor the manufacturer know or have reason to know the application to which the user will put the product. Neither EcoWater Systems LLC nor the vendor shall be liable for any injury, loss or damage, direct or consequential, arising out of the use or inability to use any item sold. Our only obligation in lieu of all warranties express or implied, is to replace any item proved to be detective. VIEW OUR WEBSITE Website: Phone: Fax: eci@ecowater.com DOMESTIC & INTERNATIONAL SHIPPING Customer service operators will advise you of availability and expected shipping. Notify Customer Service (within 5 days) if there is any error in your shipment. Merchandise cannot be returned without prior authorization. INTERNATIONAL ORDERS Pro forma invoices are sent on request. We accept certified checks, wire transfers of funds or irrevocable letters of credit. Send all inquiries to EcoWater Systems, LLC Sales Department Woodbury, MN. Export quotation pricing is in US dollars and Ex Works shipping point. International orders requiring special handling, packaging, consular invoices, certificates of origin, inspection certificates, etc are subject to additional charges. Special export packaging can be supplied when required or specified. Terms and conditions of sale apply at all times. Copyright by EcoWater Systems LLC All rights reserved. Except as permitted under the United States Copyright Act of 1976, no part of this publication may be reproduced or distributed in any form or by any means, stored in a database or retrieval system, without the prior written permission of EcoWater Systems LLC. v Catalog NP Rev. F (05/17) Effective 05/01/17

6

7 Fleck Top Mount Section 1 Fiberglass Softeners Fleck Top Mount Fiberglass Softeners *Shown with factory SKID & Interconnecting Plumbing *Shown with factory SKID & Interconnecting Plumbing Section 01 Fleck Top Mount Fiberglass Softeners Catalog NP Rev. F (05/17) Effective 05/01/17

8 Section 1 Table of Contents Fleck Top Mount Fiberglass Softeners Fiberglass Softener Specifications And Design Data Simplex Softeners FRP s Recommended Resin And Gravel Loading Duplex Parallel Softeners FRP s Recommended Resin And Gravel Loading Fleck Configurations VIP 1E Control Simplex Softener, FRP VIP 1E Control Twin Alternating Softener, FRP s VIP 1E Control Duplex Alternating Softeners, FRP s VIP 1E Control Duplex Parallel Softeners, FRP VIP 2/3E Control Duplex Alternating Or Parallel Softeners, FRP s VIP 2/3E Control Triplex Alternating Or Parallel Softener, FRP s VIP 2/3E Control Quadraplex Alternating Or Parallel Softener, FRP s Time Clock Control Simplex Softener, FRP Time Clock Control Duplex Softener, FRP s Softener Components And Accessories Skid Mounting, Interconnecting Piping Assembly (ICP) & Sample Valve / Press Gauge Controls (VIP Stagers, Micro T) VIP Control Extension Cables Transformers Water Meters and Flow Sensor Extension Cables Flow Sensor Extension Cables Assemblies well / Aircheck Assemblies /2850 Stop Valve Assemblies Replacement Fleck Power Heads Fleck Valve Covers Section 01 Fleck Top Mount Fiberglass Softeners Catalog NP Rev. F (05/17) Effective 05/01/17

9 Fleck Top Mount Section 1 Fiberglass Softeners Fiberglass Softener Specifications and Design Data Fleck Simplex Units FRP s Grains (2) Recommended Flow Rates Salt Setting Continuous Peak (3) 15lb/CF 10lb/CF 5lb/CF GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. (4) in. Resin Qty Cu. Ft. Max Drain Flow GPM Space (5) Reqmt LxDxH in. S-31-A 30,000 25,000 20, x x18x62 S-61A 60,000 50,000 40, x x18x60 S-91A 90,000 75,000 60, x x18x71 S-91B 90,000 75,000 60, x x18x71 S-121B 120, ,000 80, x x24x72 S-151B 150, , , x x24x72 S-301B 300, , , x x24x82 S-121C 120, ,000 80, x x24x72 S-151C 150, , , x x24x72 S-301C 300, , , x x24x87 S-451C 450, , , x x30x100 S-601C 600, , , x x24x100 S-451E 450, , , x x32x104 S-601E 600, , , x x42x104 S-901E 900, , , x x42x112 S-1201E 1,200,000 1,000, , x x52x112 NOTES: (1) Weight and pressure drop data are estimates. (2) Exchange capacity is based upon treating water with 10 gpg total hardness, as CaCO3 at the service rates specified and free of color, odor and turbidity. is for both tanks. (3) Peak flow rates are not recommended for extended periods of time. (4) Dimension refers to nominal vessel size only. (5) Not including operating and maintenance areas. Quantity of Resin and Gravel required per above specifications 9x48 12x52 14x65 16x65 18x65 24x72 30x72 36x72 42x72 48x72 Resin Qty. 1 cu. ft. 2 cu. ft. 3 Cu. Ft. 4 Cu. Ft. 5 Cu. Ft. 10 Cu. Ft. 15 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. Gravel Qty. 12 lbs 25 lbs 50 lbs 100 lbs 100 lbs 150 lbs 250 lbs 300 lbs 400 lbs 600 lbs Effective 05/01/17 1-1

10 Section 1 Fleck Top Mount Fiberglass Softeners Fiberglass Softener Specifications and Design Data (cont d) Fleck Duplex Parallel Units FRP s Grains (2) Salt Setting Recommended Flow Rates Duplex Duplex Peak Continuous (3) GPM Flow PSI Drop GPM Flow PSI Drop (2) Mineral in. (4) in. Resin Qty Cu.Ft. Max Drain Flow GPM Space (5) Reqmt LxDxH in. 15lb/cf 10lb/cf 5lb/cf S-31A 60,000 50,000 40, x x18x62 S-61A 120, ,000 80, x x18x60 S-91A 180, , , x x18x71 S-91B 180, , , x65 1½ x18x71 S-121B 240, , , x65 1½ x24x72 S-151B 300, , , x65 1½ x24x72 S-301B 600, , , x72 1½ x24x82 S-121C 240, , , x x24x72 S-151C 300, , , x x24x72 S-301C 600, , , x x24x87 S-451C 900, , , x x32x100 S-601C 1,200,000 1,000, , x x42x100 S-451E 900, , , x x32x104 S-601E 1,200,000 1,000, , x x42x104 S-901E 1,800,000 1,500,000 1,200, x x42x112 S-1201E 2,400,000 2,000,000 1,600, x x52x112 NOTES (1) Weight and pressure drop data are estimates. (2) Exchange capacity is based upon treating water with 10 gpg total hardness, as CaCO 3 at the service rates specified and free of color, odor and turbidity. is for both tanks. (3) Peak flow rates are not recommended for extended periods of time. (4) Dimension refers to nominal vessel size only. (5) Not including operating and maintenance areas. Quantity of Resin and Gravel required per above specifications (2)9x48 (2)12x52 (2)14x65 (2)16x65 (2)18x65 (2)24x72 (2)30x72 (2)36x72 (2)42x72 (2)48x72 Resin Qty. 2 Cu. Ft. 4 Cu. Ft. 6 Cu. Ft. 8 Cu. Ft. 10 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. 60 Cu. Ft. 80 Cu. Ft. Gravel Qty. 24 lbs 50 lbs 100 lbs 200 lbs 200 lbs 300 lbs 500 lbs 600 lbs 800 lbs 1200 lbs Effective 05/01/17 1-2

11 Fleck Top Mount Section 1 Fiberglass Softeners VIP 1E Control Simplex Demand Softener FRP Simplex = Simplex tank operation. Hard water bypass during regeneration. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, resettable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Fleck Valve Type (grains) Mineral (inches) S-301C-SNGL 1 S-31A-SNGL ,000 9 x x S-61A-SNGL ,000 1x x S-91A-SNGL , x x S-91B-SNGL , x x S-121B-SNGL , x x S-151B-SNGL , x x S-301B-SNGL , x x S-121C-SNGL , x x S-151C-SNGL , x x S-301C-SNGL , x7 1, x50 1,000 S-451C-SNGL , x7 1, x50 1,490 S-601C-SNGL , x7 2, x48 1,880 3 S-451E-SNGL , x7 1, x50 1,515 3 S-601E-SNGL , x7 2, x48 1, S-901E-SNGL ,000 4x7 2, x48 2,835 3 S-1201E-SNGL ,200, x7 4,500 5x60 3,670 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Ship Wt. Effective 05/01/17 1-3

12 Section 1 VIP 1E Control Twin Alternating Softener FRP ALT 1 Fleck Top Mount Fiberglass Softeners = Twin alternating operation; No hard water bypass during regeneration. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Lead-free brass multi-port control valves with self- cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices) = Standard safety-float valve shutoff on 400/700lb brine tanks; Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. S-61A-ALT1 Fleck Valve Type (grains) Mineral (inches) 1 S-31A-ALT ,000 9 x x S-61A-ALT ,000 1x x S-91A-ALT , x x S-91B-ALT , x x S-121B-ALT , x x S-151B-ALT , x x S-301B-ALT , x7 1, x Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Ship Wt. Effective 05/01/17 1-4

13 Fleck Top Mount Section 1 Fiberglass Softeners VIP 1E Control Duplex Alternating Softener FRP ALT 2 = Duplex alternating operation; No hard water bypass during regeneration. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Lead-free brass multi-port control valves with self- cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. S-301C-ALT2 Fleck Valve Type (grains) Mineral (inches) 1 S-31A-ALT ,000 9 x x S-61A-ALT ,000 1x x S-91A-ALT , x x S-91B-ALT , x x S-121B-ALT , x x S-151B-ALT , x x41 1, S-301B-ALT , x7 1, x50 2,270 S-121C-ALT , x x41 1,060 S-151C-ALT , x x41 1, S-301C-ALT , x7 1, x50 2,000 S-451C-ALT , x7 1, x50 2,980 S-601C-ALT , x7 2, x48 3,760 3 S-451E-ALT , x7 1, x50 3,030 3 S-601E-ALT , x7 2, x48 3, S-901E-ALT ,000 4x7 2, x48 5,670 3 S-1201E-ALT ,200, x7 4,500 5x60 7,340 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order Ship Wt. Effective 05/01/17 1-5

14 Section 1 VIP 1E Control Duplex Parallel Softener FRP PAR2 Fleck Top Mount Fiberglass Softeners = Duplex parallel operation; No hard water bypass during regeneration. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Par 2 Systems utilize one pipe size larger flow meter! = Lead-free brass multi-port control valves with self- cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. S-301C-PAR2 Fleck Valve Type (grains) Mineral (inches) 1 S-31A-PAR ,000 9 x x S-61A-PAR ,000 1x x S-91A-PAR , x x S-91B-PAR , x x S-121B-PAR , x x S-151B-PAR , x x41 1, S-301B-PAR , x7 1, x50 2,270 S-121C-PAR , x x41 1,060 S-151C-PAR , x x41 1, S-301C-PAR , x7 1, x50 2,000 S-451C-PAR , x7 1, x50 2,980 S-601C-PAR , x7 2, x48 3,760 3 S-451E-PAR , x7 1, x50 3,030 3 S-601E-PAR , x7 2, x48 3, S-901E-PAR ,000 4x7 2, x48 5,670 3 S-1201E-PAR ,200, x7 4,500 5x60 7,340 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Note: Duplex parallel systems have next size larger flow meter to handle double the flow rate. If not required, order duplex alternating system on previous page and program for parallel mode. Ship Wt. Effective 05/01/17 1-6

15 Fleck Top Mount Section 1 Fiberglass Softeners VIP 2/3E Control Duplex Softener FRP Alternating or Parallel = Twin alternating or parallel operation; No hard water bypass during regeneration. = VIP 2E electronic metered or time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = VIP 2E - Systems utilize individual tank flow meters, allowing expansion up to four future tanks. = Lead-free brass multi-port control valves with self- cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. S-301C-VIP2-D Fleck Valve Type (grains) Mineral (inches) 1 S-31A-VIP2-D ,000 9 x x S-61A-VIP2-D ,000 1x x S-91A-VIP2-D , x x S-91B-VIP2-D , x x S-121B-VIP2-D , x x S-151B-VIP2-D , x x41 1, S-301B-VIP2-D , x7 1, x50 2,270 S-121C-VIP2-D , x x41 1,060 S-151C-VIP2 -D , x x41 1,160 S-211C-VIP2-D , x7 1, x50 1, S-301C-VIP2-D , x7 1, x50 2,000 S-451C-VIP2-D , x7 1, x50 2,980 S-601C-VIP2-D , x7 2, x48 3,760 3 S-451E-VIP2-D , x7 1, x50 3,030 3 S-601E-VIP2-D , x7 2, x48 3, S-901E-VIP2-D ,000 4x7 2, x48 5,260 3 S-1201E-VIP2-D ,200, x7 4,500 5x60 6,870 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Ship Wt. Effective 05/01/17 1-7

16 Section 1 VIP 2/3E Control Triplex Softener FRP Alternating or Parallel Fleck Top Mount Fiberglass Softeners = Triplex alternating or parallel operation. No hard water bypass during regeneration. = VIP 2E electronic metered or time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems utilize individual tank flow meters, allowing expansion up to four future tanks. = Lead-free brass multi-port control valves with self- cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety float valve shutoff on 400/700lb brine tanks. Optional on S-301C-VIP2-T 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/ NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Fleck Valve Type (grains) Mineral (inches) 1 S-31A-VIP2-T ,000 9 x x S-61A-VIP2-T ,000 1x x S-91A-VIP2-T , x x40 1, S-91B-VIP2-T , x x40 1, S-121B-VIP2-T , x x41 1, S-151B-VIP2-T , x x41 1, S-301B-VIP2-T , x7 1, x50 3,405 S-121C-VIP2-T , x x41 1,590 S-151C-VIP2-T , x x41 1, S-301C-VIP2-T , x7 1, x50 3,000 S-451C-VIP2-T , x7 1, x50 4,470 S-601C-VIP2-T , x7 2, x48 5,640 3 S-451E-VIP2-T , x7 1, x50 4,520 3 S-601E-VIP2-T , x7 2, x48 5, S-901E-VIP2-T ,000 4x7 2, x48 8,496 3 S-1201E-VIP2-T ,200, x7 4,500 5x60 11,010 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Ship Wt. Effective 05/01/17 1-8

17 Fleck Top Mount Section 1 Fiberglass Softeners VIP 2/3E Control Quadraplex Softener FRP Alternating or Parallel = Quadraplex alternating or parallel operation. No hard water bypass during regeneration. = VIP 2E electronic metered or time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems offer individual tank flow meters. = Lead-free brass multi-port control valves with self- cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. S-301C-VIP2-Q = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/ NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Fleck Valve Type (grains) Mineral (inches) 1 S-31A-VIP2-Q ,000 9 x x S-61A-VIP2-Q ,000 1x x S-91A-VIP2-Q , x x40 1, S-91B-VIP2-Q , x x40 1, S-121B-VIP2-Q , x x41 1, S-151B-VIP2-Q , x x41 2, S-301B-VIP2-Q , x7 1, x50 4,540 S-121C-VIP2-Q , x x41 2,120 S-151C-VIP2-Q , x x41 2,320 S-241C-VIP2-Q , x7 1, x50 3, S-301C-VIP2-Q , x7 1, x50 4,000 S-451C-VIP2-Q , x7 1, x50 5,960 S-601C-VIP2-Q , x7 2, x48 7,520 3 S-451E-VIP2-Q , x7 1, x50 6,080 3 S-601E-VIP2-Q , x7 2, x48 7, S-901E-VIP2-Q ,000 4x7 2, x48 11,340 3 S-1201E-VIP2-Q ,200, x7 4,500 5x60 14,680 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Ship Wt. Effective 05/01/17 1-9

18 Section 1 Time Clock Control Simplex Softener FRP - Simplex Fleck Top Mount Fiberglass Softeners = Automatic mechanical time clock initiated regeneration. Hard water bypass during regeneration. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH operation. 7 Day Mech. Time Clock S-301C-TC Fleck Valve Type (grains) Mineral (inches) 1 S-31A-TC ,000 9 x x S-61A-TC ,000 1x x S-91A-TC , x x S-91B-TC , x x S-121B-TC , x x S-151B-TC , x x S-301B-TC , x7 1, x S-121C-TC , x x S-151C-TC , x x S-301C-TC , x7 1, x50 1,000 S-451C-TC , x7 1, x50 1,490 S-601C-TC , x7 2, x48 1,880 3 S-451E-TC , x7 1, x50 1,515 3 S-601E-TC , x7 2, x48 1, S-901E-TC ,000 4x7 2, x48 2,835 3 S-1201E-TC ,200, x7 4,500 5x60 3,670 Ship Wt. Effective 05/01/

19 Fleck Top Mount Section 1 Fiberglass Softeners Time Clock Control Dual Softener FRP Duplex Parallel = Automatic mechanical time clock initiated regeneration. No hard water bypass during regeneration. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH operation. 7 Day Mech. Time Clock S-301C-TC-D 1 Fleck Valve Type (grains) Mineral (inches) S-61A-TC-D ,000 1x x Ship Wt. S-31A-TC-D ,000 9 x x S-91A-TC-D , x x S-91B-TC-D , x x S-121B-TC-D , x x S-151B-TC-D , x x41 1, S-301B-TC-D , x7 1, x50 2,270 S-121C-TC-D , x x41 1,060 S-151C-TC-D , x x41 1, S-301C-TC-D , x7 1, x50 2,000 S-451C-TC-D , x7 1, x50 2,980 S-601C-TC-D , x7 2, x48 3,760 3 S-451E-TC-D , x7 1, x50 3,030 3 S-601E-TC-D , x7 2, x48 3, S-901E-TC-D ,000 4x7 2, x48 5,670 3 S-1201E-TC-D ,200, x7 4,500 5x60 7,340 Effective 05/01/

20 Section 1 Softener Components and Accessories Fleck Top Mount Fiberglass Softeners Skid Mounting: Factory assembled skid mounting for FRP Duplex Softener with mounting hardware & FRP tank supports. Diameters Valve Skid LxWxH 9 thru x30 x thru & 4x30 x thru & 7x4x & 84 x48 x x54 x x60 x Interconnecting Piping Assembly (ICP): The interconnecting plumbing headers are sized based on the flow rate and designed for a maximum velocity of 10 feet per second. Factory assembled Sch80 PVC Duplex Interconnecting piping / plumbing assembly: Description 1 Common I/O headers & bypass line with isolation valve. Includes: 1 tank I/O piping, manual tank I/O isolation valves. 1.5 Common I/O headers & bypass line with isolation valve. Includes: 1.5 tank I/O piping, manual tank I/O isolation valves. Common I/O headers & bypass line with isolation valve. Includes: tank I/O piping, manual tank I/O isolation valves. 3 Common I/O headers & bypass line with isolation valve. Includes: tank I/O piping, manual tank I/O isolation valves. 3 Common I/O headers & bypass line with isolation valve. Includes: 3 tank I/O piping, manual tank I/O isolation valves. 4 Common I/O headers & bypass line with isolation valve. Includes: 3 tank I/O piping, manual tank I/O isolation valves Note: Galvanized piping is available contact factory for pricing. Kit: Sample Valve & Pressure Gauge Description Kit: 2.5 Pressure Gauge 0-100psi with ¼ Tee & ¼ Sample Valve Test Cock Used on above factory assembled inlet/outlet headers for ICP. Note: Skid number, ICP number and gauge/sample valve kit(s) number consummate a complete assembly. Effective 05/01/

21 Fleck Top Mount Section 1 Fiberglass Softeners Controls VIP 1E & VIP 2E demand initiated controllers have the following standard features. They directly replace older style VIP controllers. = Electronic time clock capability = Delay regeneration on alternating systems = UL listing VIP 3E controllers allow for progressive flow capabilities; as the flow rate increases or decreases the controller will move units into and out of service. This eliminates the possibility of channeling through the resin during low flow conditions and lessens the pressure drop through the system during high flow conditions. Ideal for applications with varying flow rate demands such as hotels, condominiums or apartment buildings. Description VIP 1E Programmable Control Simplex or Duplex VIP 2E Programmable Control 2, 3, or 4 s VIP 3E Variable-Demand Programmable Control Time Clock Valve Nest System w/solenoids for filters Stager Control Valve Nest System Micro-TR Time Clock with RO Lockout Board ( Mount) Pumped Control Reclaim Control Day Control VIP Mounting Kit VIP 1E CONTROL VIP 2/3E CONTROL MICRO-T CONTROL STAGER CONTROL Effective 05/01/

22 Section 1 VIP Control Extension Cables Fleck Top Mount Fiberglass Softeners Length (ft.) Description 10 Extends harness from valve to control Transformers Description 50 VA 120v x 24vac Plug In VA 120v x 24vac (NEMA BOX) VA 220v x 24vac (NEMA BOX) VA 120V x 24vac (Encapsulated) FLK41034 Water Meters and Flow Sensors Turbo Flow Meters All VIP water softener and filter systems come with flow sensors. The standard 1, 1.5 and flow meter in a plastic housing can be replaced with a brass housing. The standard 3 & 4 flow sensor in a copper tee assembly can be replaced with a PVC saddle fitting or an iron saddle fitting. Description Flow Rate (gpm) Normal Range Peak 1 NPT Flow Meter PVC NPT Flow Meter PVC NPT Brass turbine assy or NPT Brass turbine assy NPT Water meter Plastic NPT Flow Meter PVC Flow Meter w/copper fitting Sensor w/pvc saddle Sensor w/copper fitting Sensor w/pvc saddle Replacement Turbine for 1, 1.5 & Replacement Sensor for 3 & Replacement Sensor does not include installation fittings: -Copper Tee -PVC Saddle -Iron Saddle Effective 05/01/

23 Fleck Top Mount Section 1 Fiberglass Softeners Flow Sensor Extension Cables Length (ft.) Description 10 Extends harness from flow sensor to control Complete Assemblies Polyethylene Systems (includes brine well and 1 air-check assembly). 400/700lb brine tanks come standard with brine well, air/check and safety float valve style shutoff. Optionally, safety float valve style shutoff on 1000lbs and above systems are offered at an additional cost only. Description Dimensions Standard Air-check (Dia. x Height) No. & List Price 400 lb capacity 18 x lb capacity 24 x ,000 lb capacity 24 x ,500 lb capacity 30 x ,500 lb capacity 39 x ,500 lb capacity 5x ,000 lb capacity 60 x ,000 lb capacity 7x well / Air-check Assemblies Standard Description 400 lb & 700 lb well / Air-check assy lb well / Air-check assy lb well / Air-check assy lb, 4500 lb, 7000 lb or 10,000 well / Aircheck assy Effective 05/01/

24 Section & Stop Valve Assemblies Description 1 Valve assy, STEEL 24v NO BYP (complete) Valve assy, STEEL 24v NO BYP (complete) Solenoid Valve, 24v (replc part) Diaph/Seal Kit, 1 vlv 421 (replc part) Diaph/Seal Kit, 1.5 vlv 424 (replc part) AQM Internal s Kit 421 f/1 (replc part) AQM Internal s Kit 424 f/1.5 (replc part) Fleck Top Mount Fiberglass Softeners Fleck Replacement Power Heads (VIP/24V) with Cables Power Head Description 2750 / 2850 Power Head, (VIP config) Power Head, (VIP config) Power Head, (VIP config) Power Head, (VIP config) /9500 Power Head, (VIP config) Covers sold separately Fleck Valve Covers Description Black Environmental Cover w/ Clear Window 2750, 2850, Upper 2900 Black Environmental Cover Lower 2900 Drive Motor Cover Black Environmental Cover w/ Clear Window 3150 & Upper 3900 Black Environmental Cover w/ Black Window 3150 & Lower 3900 FLK FLK FLK FLK Effective 05/01/

25 Fleck Epoxy Lined Section 2 Steel Softeners Fleck Epoxy Lined Steel Softeners *Shown with factory SKID & Plumbing Section 02 Fleck Epoxy Lined Steel Softeners Catalog NP Rev. F (05/17) Effective 05/01/17

26 Section 2 Table of Contents Fleck Epoxy Lined Steel Softeners Steel Softener Specifications And Design Data Simplex Units Epoxy Lined Carbon Steel s Recommended Resin And Gravel Loading Duplex Units Epoxy Lined Carbon Steel s Recommended Resin And Gravel Loading Configuration VIP 1E Softener, Epoxy Lined Steel Simplex VIP 1E Softener, Epoxy Lined Steel Twin Alternating VIP 1E Softener, Epoxy Lined Steel Duplex Alternating VIP 1E Softener, Epoxy Lined Steel Duplex Parallel VIP 2E Softener, Epoxy Lined Steel Duplex Alternating Or Parallel VIP 2E Softener, Epoxy Lined Steel Triplex Alternating Or Parallel VIP 2E Softener, Epoxy Lined Steel Quadraplex Alternating Or Parallel Time Clock Softener, Epoxy Lined Steel Simplex Time Clock Softener, Epoxy Lined Steel Duplex Section 02 Fleck Epoxy Lined Steel Softeners Catalog NP Rev. F (05/17) Effective 05/01/17

27 Fleck Epoxy Lined Section 2 Steel Softeners Steel Softener Specifications and Design Data Simplex Units Epoxy Lined Carbon Steel s Recommended Flow Rates Grains (2) Mineral Max Continuous Peak (3) Resin Space Drain Qty Reqmt Salt Setting GPM PSI GPM PSI Flow in. Cu.Ft. LxDxH in. in. (4) GPM 15lb/cf 10lb/cf 5lb/cf Flow Drop Flow Drop S-92A 90,000 75,000 60, x x18x72 S-92B 90,000 75,000 60, x66 1½ x18x72 S-122B 120, ,000 80, x66 1½ x24x72 S-152B 150, , , x66 1½ x24x72 S-302B 300, , , x66 1½ x24x72 S-122C 120, ,000 80, x x24x77 S-152C 150, , , x x24x77 S-302C 300, , , x x24x77 S-452C 450, , , x x30x77 S-602C 600, , , x x39x82 S-452E 450, , , x x30x86 S-602E 600, , , x x42x86 S-902E 900, , , x x42x86 S-1202E 1,200,000 1,000, , x x52x86 NOTES: (1) Weight and pressure drop data are estimates. (2) Exchange capacity is based upon treating water with 10 gpg total hardness as CaCO 3 at the service rates specified and free of color, odor and turbidity. is for both tanks. (3) Peak flow rates are not recommended for extended periods of time. (4) Dimension refers to nominal vessel size only. (5) Not including operating and maintenance areas. Resin and Gravel required per above specifications 14x66 18x66 (S-122) 18x66 (S-152) 24x66 30x66 36x70 42x70 48x70 Resin Qty. 3 Cu. Ft. 4 Cu. Ft. 5 Cu. Ft. 10 Cu. Ft. 15 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. Gravel Qty. 50 lbs 100 lbs 100 lbs 150 lbs 250 lbs 300 lbs 400 lbs 600 lbs Effective 05/01/17 2-1

28 Section 2 Fleck Epoxy Lined Steel Softeners Steel Softener Specifications and Design Data (cont d) Duplex Parallel Units Epoxy Lined Carbon Steel s Total System Grains (2) Recommended Flow Rates Duplex Continuous Duplex Peak (3) (2) Mineral in. (4) in. Total Resin Qty Cu.Ft. Max Drain Flow GPM Space (5) Reqmt LxDxH in. Salt Setting GPM PSI GPM PSI 15lb/cf 10lb/cf 5lb/cf Flow Drop Flow Drop S-92A 180, , , x x18x72 S-92B 180, , , x66 1½ x18x72 S-122B 240, , , x66 1½ x24x72 S-152B 300, , , x66 1½ x24x72 S-302B 600, , , x66 1½ x24x72 S-122C 240, , , x x24x77 S-152C 300, , , x x24x77 S-302C 600, , , x x24x77 S-452C 900, , , x x30x77 S-602C 1,200,000 1,000, , x x42x82 S-452E 900, , , x x30x86 S-602E 1,200,000 1,000, , x x42x86 S-902E 1,800,000 1,500,000 1,200, x x42x86 S-1202E 2,400,000 2,000,000 1,600, x x52x86 NOTES: (1) Weight and pressure drop data are estimates. (2) Exchange capacity is based upon treating water with 10 gpg total hardness as CaCO 3 at the service rates specified and free of color, odor and turbidity. is for both tanks. (3) Peak flow rates are not recommended for extended periods of time. (4) Dimension refers to nominal vessel size only. (5) Not including operating and maintenance areas. (2)14x66 (2)18x66 (S-122) Resin and Gravel required per above specifications (2)18x66 (S-152) (2) 24x66 (2) 30x66 (2) 36x70 (2) 42x70 (2) 48x70 Resin Qty. 6 Cu. Ft. 8 Cu. Ft. 10 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. 60 Cu. Ft. 80 Cu. Ft. Gravel Qty. 100 lbs 200 lbs 200 lbs 300 lbs 500 lbs 600 lbs 800 lbs 1200 lbs Effective 05/01/17 2-2

29 Fleck Epoxy Lined Section 2 Steel Softeners VIP 1E Control Simplex Demand Softener Epoxy Lined Steel Simplex = Simplex tank operation. Hard water bypass during regeneration. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. S-301C-SNGL Fleck Valve Type Per (kilograins) Mineral (inches) S-92A-SNGL , x x S-92B-SNGL , x x S-122B-SNGL , x x S-152B-SNGL , x x S-302B-SNGL , x66 1, x50 1,245 S-122C-SNGL , x x S-152C-SNGL , x x S-302C-SNGL , x66 1, x50 1,075 S-452C-SNGL , x66 1, x50 1,565 S-602C-SNGL , x71 2, x48 1,955 3 S-452E-SNGL , x66 1, x50 1,615 3 S-602E-SNGL , x71 2, x48 2, S-902E-SNGL ,000 4x71 2, x48 2,825 3 S-1202E-SNGL ,200, x71 4,500 5x60 3,660 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Ship. Wt. Effective 05/01/17 2-3

30 Section 2 VIP 1E Control Twin Alternating Softener Epoxy Lined Steel ALT 1 = Twin alternating. No hard water bypass during regeneration. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. = Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. Fleck Epoxy Lined Steel Softeners S-302B-ALT1 Fleck Valve Type Per (kilograins) Mineral (inches) S-92A-ALT , x x S-92B-ALT , x x S-122B-ALT , x x S-152B-ALT , x x41 1, S-302B-ALT , x66 1, x50 2,245 Ship. Wt. Note: 1 & 1.5 flow meters supplied with above products are Plastic. Effective 05/01/17 2-4

31 Fleck Epoxy Lined Section 2 Steel Softeners VIP 1E Control Duplex Alternating Softener Epoxy Lined Steel ALT 2 = Twin alternating operation. No hard water bypass during regeneration. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, resettable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. S-302E-ALT2 Fleck Valve Type Per (kilograins) Mineral (inches) S-92A-ALT , x x S-92B-ALT , x x S-122B-ALT , x x S-152B-ALT , x x41 1, S-302B-ALT , x66 1, x50 2,270 S-122C-ALT , x x41 1,060 S-152C-ALT , x x41 1, S-302C-ALT , x66 1, x50 2,000 S-452C-ALT , x66 1, x50 2,980 S-602C-ALT , x71 2, x48 3,760 3 S-452E-ALT , x66 1, x50 2,980 3 S-602E-ALT , x71 2, x 48 3, S-902E-ALT ,000 4x71 2, x 48 5,670 3 S-1202E-ALT ,200, x71 4,500 5 x 60 7,340 Ship. Wt. Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/17 2-5

32 Section 2 VIP 1E Control Duplex Parallel Softener Epoxy Lined Steel PAR2 Fleck Epoxy Lined Steel Softeners = Duplex parallel operation. No hard water bypass during regeneration. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = Par 2 Systems utilize one pipe size larger flow meter! = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. S-302C-PAR2 Fleck Valve Type Per (kilograins) Mineral (inches) S-92A-PAR , x x S-92B-PAR , x x S-122B-PAR , x x S-152B-PAR , x x41 1, S-302B-PAR , x66 1, x50 2,270 S-122C-PAR , x x41 1,060 S-152C-PAR , x x41 1, S-302C-PAR , x66 1, x50 2,000 S-452C-PAR , x66 1, x50 2,980 S-602C-PAR , x71 2, x48 3,760 3 S-452E-PAR , x66 1, x50 3,030 3 S-602E-PAR , x71 2, x 48 3, S-902E-PAR ,000 4x71 2, x 48 5,670 3 S-1202E-PAR ,200, x71 4,500 5 x 60 7,340 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Note: Duplex parallel systems have next size larger flow meter to handle double the flow rate. If not required, order duplex alternating system on previous page and program for parallel mode. Ship. Wt. Effective 05/01/17 2-6

33 Fleck Epoxy Lined Section 2 Steel Softeners VIP 2E Control Duplex Softener Epoxy Lined Steel Alternating or Parallel = Twin alternating or parallel operation. No hard water bypass during regeneration = VIP 2E electronic time clock feature & UL listed. = Solid State multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems utilize individual tank flow meters, allowing expansion up to four future tanks. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. S-302C-VIP2D Fleck Valve Type Per (kilograins) Mineral (inches) S-92A-VIP2-D , x x S-92B-VIP2-D , x x S-122B-VIP2-D , x x S-152B-VIP2-D , x x41 1, S-302B-VIP2-D , x66 1, x50 2,270 S-122C-VIP2-D , x x41 1,060 S-152C-VIP2-D , x x41 1, S-302C-VIP2-D , x66 1, x50 2,000 S-452C-VIP2-D , x66 1, x50 2,980 S-602C-VIP2-D , x71 2, x48 3,760 3 S-452E-VIP2-D , x66 1, x50 2,980 3 S-602E-VIP2-D , x71 2, x 48 3, S-902E-VIP2-D ,000 4x71 2, x 48 5,260 3 S-1202E-VIP2-D ,200, x71 4,500 5 x 60 6,870 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Ship. Wt. Effective 05/01/17 2-7

34 Section 2 VIP 2E Control Triplex Softener Epoxy Lined Steel Alternating or Parallel Fleck Epoxy Lined Steel Softeners = Triplex alternating or parallel operation. No hard water bypass during regeneration. = VIP 2E electronic time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems utilize individual tank flow meters, allowing expansion up to four future tanks. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. S-302C-VIP2-T = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Fleck Valve Type Per (kilograins) Mineral (inches) S-92A-VIP2-T , x x40 1, S-92B-VIP2-T , x x40 1, S-122B-VIP2-T , x x41 1, S-152B-VIP2-T , x x41 1, S-302B-VIP2-T , x66 1, x50 3,405 S-122C-VIP2-T , x x41 1,590 S-152C-VIP2-T , x x41 1, S-302C-VIP2-T , x66 1, x50 3,000 S-452C-VIP2-T , x66 1, x50 4,470 S-602C-VIP2-T , x71 2, x48 5,640 3 S-452E-VIP2-T , x66 1, x50 4,520 3 S-602E-VIP2-T , x71 2, x 48 5, S-902E-VIP2-T ,000 4x71 2, x 48 8,496 3 S-1202E-VIP2-T ,200, x71 4,500 5 x 60 11,010 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Ship. Wt. Effective 05/01/17 2-8

35 Fleck Epoxy Lined Section 2 Steel Softeners VIP 2E Control Quadraplex Softener Epoxy Lined Steel Alternating or Parallel = Quadraplex alternating or parallel operation. No hard water bypass during regeneration. = VIP 2E electronic time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems offer individual tank flow meters. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for S-302C-VIP2-Q corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Fleck Valve Type Per (kilograins) Mineral (inches) S-92A-VIP2-Q , x x40 1, S-92B-VIP2-Q , x x40 1, S-122B-VIP2-Q , x x41 1, S-152B-VIP2-Q , x x41 2, S-302B-VIP2-Q , x66 1, x50 4,540 S-122C-VIP2-Q , x x41 2,120 S-152C-VIP2-Q , x x41 2, S-302C-VIP2-Q , x66 1, x50 4,000 S-452C-VIP2-Q , x66 1, x50 5,960 S-602C-VIP2-Q , x71 2, x48 7,520 3 S-452E-VIP2-Q , x66 1, x50 6,010 3 S-602E-VIP2-Q , x71 2, x 48 7, S-902E-VIP2-Q ,000 4x71 2, x 48 11,340 3 S-1202E-VIP2-Q ,200, x71 4,500 5 x 60 14,680 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Ship. Wt. Effective 05/01/17 2-9

36 Section 2 Time Clock- Softener Epoxy Lined Steel Simplex Fleck Epoxy Lined Steel Softeners = Automatic mechanical time clock initiated regeneration. = Hard water bypass during regeneration. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH operation. 7 Day Mech. Time Clock S-302C-TC Fleck Valve Type (Kilograins) Mineral (inches) S-92A-TC , x x S-92B-TC , x x S-122B-TC , x x S-152B-TC , x x S-302B-TC , x66 1, x50 1,135 S-122C-TC , x x S-152C-TC , x x S-302C-TC , x66 1, x50 1,000 S-452C-TC , x66 1, x50 1,490 S-602C-TC , x71 2, x48 1,880 3 S-452E-TC , x66 1, x50 1,540 3 S-602E-TC , x71 2, x48 1, S-902E-TC ,000 4x71 2, x48 2,835 3 S-1202E-TC ,200, x x60 3,670 Ship. Wt. Effective 05/01/

37 Fleck Epoxy Lined Section 2 Steel Softeners Time Clock - Softener Epoxy Lined Steel - Duplex = Automatic mechanical time clock initiated regeneration. = No hard water bypass during regeneration. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH operation. 7 Day Mech. Time Clock S-302C-TC-D Fleck Valve Type Per (kilograins) Mineral (inches) S-92A-TC-D , x x S-92B-TC-D , x x S-122B-TC-D , x x S-152B-TC-D , x x S-302B-TC-D , x x S-122C-TC-D , x x S-152C-TC-D , x x S-302C-TC-D , x x S-452C-TC-D , x x S-602C-TC-D , x x S-452E-TC-D , x x S-602E-TC-D , x x S-902E-TC-D ,000 4x x S-1202E-TC-D ,200, x x Ship. Wt. Effective 05/01/

38

39 Plastic Valve Nest Fiberglass Section 3 Softeners - 18 thru 48 Plastic Valve Nest Fiberglass Softeners 18 thru 48 Section 03 Fiberglass PVC Valve Nest Softeners Catalog NP Rev. F (05/17) Effective 05/01/17

40 Section 3 Table of Contents Plastic Valve Nest Fiberglass Softeners - 18 thru 48 Fiberglass Softener Specifications And Design Data Simplex Softeners FRP s Duplex Parallel Softeners FRP s Recommended Resin And Gravel Loading Configurations VIP 1E Plastic Valve Nest Softener, FRP Simplex VIP 1E Plastic Valve Nest Softener, FRP Duplex VIP 2E Plastic Valve Nest Softener, FRP Duplex Alt Or Par VIP 2E Plastic Valve Nest Softener, FRP Triplex Alt Or Par VIP 2E Plastic Valve Nest Softener, FRP Quadraplex Alt Or Par Time Clock Plastic Valve Nest Softener, FRP - Simplex Time Clock Plastic Valve Nest Softener, FRP - Duplex Section 03 Fiberglass PVC Valve Nest Softeners Catalog NP Rev. F (05/17) Effective 05/01/17

41 Plastic Valve Nest Fiberglass Section 3 Softeners - 18 thru 48 Fiberglass Softener Specifications and Design Data Simplex Units FRP s Grains (2) Recommended Flow Rates Salt Setting Continuous Peak (3) 15lb/CF 10lb/CF 5lb/CF GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. (4) in. Resin Qty Cu.Ft. Max Drain Flow GPM Space (5) Reqmt LxDxH in. S-151C 150, , , x x24x86 S-301C 300, , , x x24x92 S-451C 450, , , x x30x92 S-601C 600, , , x x24x92 S-901E 900, , , x x42x96 S-1201E 1,200,000 1,000, , x x52x100 Duplex Parallel Units FRP s Total System Grains (2) Salt Setting 15lb/cf 10lb/cf 5lb/cf Recommended Flow Rates Duplex Continuous GPM Flow PSI Drop Duplex Peak (3) GPM Flow PSI Drop (2) Mineral in. (4) in. Total Resin Qty Cu.Ft. Max Drain Flow GPM Space (5) Reqmt LxDxH in. S-151C 300, , , x x24x86 S-301C 600, , , x x24x92 S-451C 900, , , x x30x92 S-601C 1,200,000 1,000, , x x24x92 S-901E 1,800,000 1,500,000 1,200, x x42x96 S-1201E 2,400,000 2,000,000 1,600, x x52x100 NOTES: (1) Weight and pressure drop data are estimates. (2) Exchange capacity is based upon treating water with 10 gpg total hardness as CaCO 3 at the service rates specified and free of color, odor and turbidity. is for both tanks. (3) Peak flow rates are not recommended for extended periods of time. (4) Dimension refers to nominal vessel size only. (5) Not including operating and maintenance areas. Quantity of Resin and Gravel required per above specifications SIMPLEX SIMPLEX SIMPLEX SIMPLEX SIMPLEX SIMPLEX 18x65 24x72 30x72 36x72 42x72 48x72 Resin Qty. 5 Cu. Ft. 10 Cu. Ft. 15 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. Gravel Qty. 100lbs 150lbs 250lbs 300lbs 400lbs 500lbs Quantity of Resin and Gravel required per above specifications DUPLEX DUPLEX DUPLEX DUPLEX DUPLEX DUPLEX (2)18x65 (2)24x72 (2)30x72 (2)36x72 (2)42x72 (2)48x72 Resin Qty. 10 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. 60 Cu. Ft. 80 Cu. Ft. Gravel Qty. 200lbs 300lbs 500lbs 600lbs 800lbs 1000lbs Effective 05/01/17 3-1

42 Section 3 Plastic Valve Nest Fiberglass Softeners - 18 thru 48 VIP 1E Control Simplex Plastic Valve Nest Softener FRP Simplex = Simplex delayed or immediate regeneration. Hard water bypass during regeneration. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. S-1201E-PVN-SNGL 3 Valve Type Plastic Valve Nest (grains) Mineral (inches) Ship Wt. S-151C-PVN-SNGL , x x S-301C-PVN-SNGL , x7 1, x50 1,000 S-451C-PVN-SNGL , x7 1, x50 1,490 S-601C-PVN-SNGL , x7 2, x48 1,910 S-901E-PVN-SNGL ,000 4x7 2, x48 2,835 S-1201E-PVN-SNGL ,200, x7 4,500 5x60 3,670 Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Effective 05/01/17 3-2

43 Plastic Valve Nest Fiberglass Section 3 Softeners - 18 thru 48 VIP 1E Control Duplex Alternating Plastic Valve Nest Softener FRP ALT 2 = Duplex alternating operation; No hard water bypass during regeneration. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer S-1201E-PVN-ALT2 service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. 3 Valve Type Plastic Valve Nest (grains) Mineral (inches) Ship Wt. S-151C-PVN-ALT , x x41 1,140 S-301C-PVN-ALT , x7 1, x50 1,840 S-451C-PVN-ALT , x7 1, x50 2,980 S-601C-PVN-ALT , x7 2, x48 3,880 S-901E-PVN-ALT ,000 4x7 2, x48 5,670 S-1201E-PVN-ALT ,200, x7 4,500 5x60 7,340 Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Effective 05/01/17 3-3

44 Section 3 Plastic Valve Nest Fiberglass Softeners - 18 thru 48 VIP 2E Control Duplex Plastic Valve Nest Softener FRP Alternating or Parallel = Duplex alternating operation; No hard water bypass during regeneration. = VIP 2E electronic metered or time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = VIP 2E - Systems utilize individual tank flow meters, allowing expansion up to four future tanks. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb S-1201E-PVN-D VIP 2 brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/ NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. 3 Valve Type Plastic Valve Nest (grains) Mineral (inches) Ship Wt. S-151C-PVN-D VIP , x x41 1,140 S-301C-PVN-D VIP , x7 1, x50 1,840 S-451C-PVN-D VIP , x7 1, x50 2,980 S-601C-PVN-D VIP , x7 2, x48 3,880 S-901E-PVN-D VIP ,000 4x7 2, x48 5,670 S-1201E-PVN-D VIP ,200, x7 4,500 5x60 7,340 Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Effective 05/01/17 3-4

45 Plastic Valve Nest Fiberglass Section 3 Softeners - 18 thru 48 VIP 2E Control Triplex Plastic Valve Nest Softener FRP Alternating or Parallel = Triplex alternating or parallel operation. No hard water bypass during regeneration. = VIP 2E electronic metered or time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems utilize individual tank flow meters, allowing expansion up to four future tanks. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for S-1201E-PVN-T VIP 2 corrosion resistance. = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Timed brine refill (eliminates constant line pressure on shut off float devices). = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/ NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. 3 Valve Type Plastic Valve Nest (grains) Mineral (inches) Ship Wt. S-151C-PVN-T VIP , x x41 1,140 S-301C-PVN-T VIP , x7 1, x50 1,840 S-451C-PVN-T VIP , x7 1, x50 2,980 S-601C-PVN-T VIP , x7 2, x48 3,880 S-901E-PVN-T VIP ,000 4x7 2, x48 5,670 S-1201E-PVN-T VIP ,200, x7 4,500 5x60 7,340 Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Effective 05/01/17 3-5

46 Section 3 Plastic Valve Nest Fiberglass Softeners - 18 thru 48 VIP 2E Control Quadraplex Plastic Valve Nest Softener FRP Alternating or Parallel = Quadraplex alternating or parallel operation. No hard water bypass during regeneration. = VIP 2E electronic metered or time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & selfdiagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems offer individual tank S-1201E-PVN-Q VIP 2 flow meters. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/ NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. 3 Valve Type Plastic Valve Nest (grains) Mineral (inches) Ship Wt. S-151C-PVN-Q VIP , x x41 1,140 S-301C-PVN-Q VIP , x7 1, x50 1,840 S-451C-PVN-Q VIP , x7 1, x50 2,980 S-601C-PVN-Q VIP , x7 2, x48 3,880 S-901E-PVN-Q VIP ,000 4x7 2, x48 5,670 S-1201E-PVN-Q VIP ,200, x7 4,500 5x60 7,340 Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Effective 05/01/17 3-6

47 Plastic Valve Nest Fiberglass Section 3 Softeners - 18 thru 48 Time Clock Micro T Control Simplex Plastic Valve Nest Softener FRP Simplex TC = Automatic electronic time clock initiated regeneration with Micro T controller. = Hard Water bypass during regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices. = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. S-1201E-PVN-TC-S 3 Valve Type Plastic Valve Nest (grains) Mineral (inches) Ship Wt. S-151C-PVN-TC-S , x x41 1,140 S-301C-PVN-TC-S , x7 1, x50 1,840 S-451C-PVN-TC-S , x7 1, x50 2,980 S-601C-PVN-TC-S , x7 2, x48 3,880 S-901E-PVN-TC-S ,000 4x7 2, x48 5,670 S-1201E-PVN-TC-S ,200, x7 4,500 5x60 7,340 Effective 05/01/17 3-7

48 Section 3 Plastic Valve Nest Fiberglass Softeners - 18 thru 48 Time Clock Micro T Control Duplex Parallel Plastic Valve Nest Softener FRP Duplex TC = Automatic electronic time clock initiated regeneration with Micro T controller. = No hard water bypass during regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. S-1201E-PVN-TC-D 3 Valve Type Plastic Valve Nest (grains) Mineral (inches) Ship Wt. S-151C-PVN-TC-D , x x41 1,140 S-301C-PVN-TC-D , x7 1, x50 1,840 S-451C-PVN-TC-D , x7 1, x50 2,980 S-601C-PVN-TC-D , x7 2, x48 3,880 S-901E-PVN-TC-D ,000 4x7 2, x48 5,670 S-1201E-PVN-TC-D ,200, x7 4,500 5x60 7,340 Effective 05/01/17 3-8

49 Plastic Valve Nest Epoxy Lined Section 4 Steel Softeners - 18 thru 48 Plastic Valve Nest Epoxy Lined Steel Softeners 18 thru 48 Section 04 Plastic Valve Nest Steel Softeners Catalog NP Rev. F (05/17) Effective 05/01/17

50 Section 4 Table of Contents Plastic Valve Nest Epoxy Lined Steel Softeners - 18 thru 48 PVC Valve Nest Softener Specifications And Design Data Simplex Units Epoxy Lined Carbon Steel s Duplex Units Epoxy Lined Carbon Steel s Recommended Resin And Gravel Loading Configuration VIP 1E Plastic Valve Nest Softener, Epoxy Lined Steel Simplex VIP 1E Plastic Valve Nest Softener, Epoxy Lined Steel Duplex VIP 2E Plastic Valve Nest Softener, Epoxy Lined Steel Duplex Alt Or Par VIP 2E Plastic Valve Nest Softener, Epoxy Lined Steel Triplex Alt Or Par ViIP 2E Plastic Valve Nest Softener, Epoxy Lined Steel Quadraplex Alt Or Par Time Clock Plastic Valve Nest Softener, Epoxy Lined Steel Simplex Time Clock Plastic Valve Nest Softener, Epoxy Lined Steel Duplex Section 04 Plastic Valve Nest Steel Softeners Catalog NP Rev. F (05/17) Effective 05/01/17

51 Plastic Valve Nest Epoxy Lined Section 4 Steel Softeners - 18 thru 48 Steel Softener Specifications and Design Data Simplex Units Epoxy Lined Steel s Grains (2) Recommended Flow Rates Salt Setting Continuous Peak (3) 15lb/CF 10lb/CF 5lb/CF GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. (4) in. Resin Qty Cu.Ft. Max Drain Flow GPM Space (5) Reqmt LxDxH in. S-152C-PVN 150, , , x x24x72 S-302C-PVN 300, , , x x24x72 S-452C-PVN 450, , , x x30x72 S-602C-PVN 600, , , x x39x78 S-902E-PVN 900, , , x x42x78 S-1202E-PVN 1,200,000 1,000, , x x52x78 Duplex Parallel Units Epoxy Lined Steel s Total System Grains (2) Salt Setting 15lb/CF 10lb/CF 5lb/CF Recommended Flow Rates (6) (2) Duplex Continuous GPM Flow PSI Drop Duplex Peak (3) GPM Flow PSI Drop Mineral in. (4) in. Total Resin Qty Cu.Ft. Max Drain Flow GPM Space (5) Reqmt LxDxH in. S-152C-PVN 300, , , x x24x72 S-302C-PVN 600, , , x x24x72 S-452C-PVN 900, , , x x30x72 S-602C-PVN 1,200,000 1,000, , x x42x78 S-902E-PVN 1,800,000 1,500,000 1,200, x x42x78 S-1202E-PVN 2,400,000 2,000,000 1,600, x x52x78 Notes: (1) Weight and pressure drop data are estimates. (2) Exchange capacity is based upon treating water with 10 gpg total hardness as CaCO 3 at the service rates specified and free of color, odor and turbidity. shown for duplex systems is the combined capacity of both tanks. (3) Peak flow rates are not recommended for extended periods of time. Flow rates reflect both softeners on line providing water. (4) Dimension refers to nominal vessel size only. (5) Not including operating and maintenance areas. Quantity of Resin and Gravel required per above specifications SIMPLEX SIMPLEX SIMPLEX SIMPLEX SIMPLEX SIMPLEX 18x66 24x66 30x66 36x70 42x70 48x70 Resin Qty. 5 Cu. Ft. 10 Cu. Ft. 15 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. Gravel Qty. 100lbs 150lbs 250lbs 300lbs 400lbs 600lbs Quantity of Resin and Gravel required per above specifications DUPLEX DUPLEX DUPLEX DUPLEX DUPLEX DUPLEX (2)18x66 (2)24x66 (2)30x66 (2)36x70 (2)42x70 (2)48x70 Resin Qty. 10 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. 60 Cu. Ft. 80 Cu. Ft. Gravel Qty. 200lbs 300lbs 500lbs 600lbs 800lbs 1200lbs Effective 05/01/17 4-1

52 Section 4 Plastic Valve Nest Epoxy Lined Steel Softeners - 18 thru 48 VIP 1E Control Simplex PVC Valve Nest Softener Epoxy Lined Steel Simplex = Simplex delayed or immediate regeneration. Hard water bypass during regeneration. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & selfdiagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for S-1201E-PVN-SNGL corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Valve Type Per (grains) Mineral (inches) S-152C-PVN-SNGL , x x S-302C-PVN-SNGL , x66 1, x50 1,075 Plastic S-452C-PVN-SNGL , x66 1, x50 1,565 Valve Nest S-602C-PVN-SNGL , x70 2, x48 1,955 3 S-902E-PVN-SNGL ,000 4x70 2, x48 2,825 3 S-1202E-PVN-SNGL ,200, x70 4,500 5x60 3,660 Ship Wt. Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Effective 05/01/17 4-2

53 Plastic Valve Nest Epoxy Lined Section 4 Steel Softeners - 18 thru 48 VIP 1E Control Duplex PVC Valve Nest Softener Epoxy Lined Steel Alternating or Parallel = Duplex alternating operation; No hard water bypass during regeneration. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line S-1202E-PVN-VIPD pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Valve Type Per (grains) Mineral (inches) S-302C-PVN-VIP1-D , x66 1, x50 2,095 Plastic S-452C-PVN-VIP1-D , x66 1, x50 3,075 Valve Nest S-602C-PVN-VIP1-D , x70 2, x48 3,855 3 S-902E-PVN-VIP1-D ,000 4x70 2, x48 5,595 3 S-1202E-PVN-VIP1-D ,200, x70 4,500 5x60 7,120 Ship Wt. S-152C-PVN-VIP1-D , x x41 1,255 Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Effective 05/01/17 4-3

54 Section 4 Plastic Valve Nest Epoxy Lined Steel Softeners - 18 thru 48 VIP 2E Control Duplex PVC Valve Nest Softener Epoxy Lined Steel Alternating or Parallel = Duplex alternating operation; No hard water bypass during regeneration. = VIP 2E electronic metered or time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems utilize individual tank flow meters, allowing expansion up to four future tanks. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion S-1202E-PVN-VIP2-D resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Valve Type Per (grains) Mineral (inches) S-302C-PVN-VIP2-D , x66 1, x50 2,095 Plastic Valve S-452C-PVN-VIP2-D , x66 1, x50 3,075 Nest S-602C-PVN-VIP2-D , x70 2, x48 3,855 Ship Wt. S-152C-PVN-VIP2-D , x x41 1,255 3 S-902E-PVN-VIP2-D ,000 4x70 2, x48 5,595 3 S-1202E-PVN-VIP2-D ,200, x70 4,500 5x60 7,120 Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Effective 05/01/17 4-4

55 Plastic Valve Nest Epoxy Lined Section 4 Steel Softeners - 18 thru 48 VIP 2E Control Triplex PVC Valve Nest Softener Epoxy Lined Steel Alternating or Parallel = Triplex alternating or parallel operation. No hard water bypass during regeneration. = VIP 2E electronic metered or time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems utilize individual S-1202E-PVN-VIP2-T tank flow meters, allowing expansion up to four future tanks. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Valve Type Per (grains) Mineral (inches) S-302C-PVN-VIP2-T , x66 1, x50 3,115 Plastic Valve S-452C-PVN-VIP2-T , x66 1, x50 4,585 Nest S-602C-PVN-VIP2-T , x70 2, x48 5,665 Ship Wt. S-152C-PVN-VIP2-T , x x41 1,855 3 S-902E-PVN-VIP2-T ,000 4x70 2, x48 8,275 3 S-1202E-PVN-VIP2-T ,200, x70 4,500 5x60 10,580 Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Effective 05/01/17 4-5

56 Section 4 Plastic Valve Nest Epoxy Lined Steel Softeners - 18 thru 48 VIP 2E Control Quadraplex PVC Valve Nest Softener Epoxy Lined Steel Alternating or Parallel = Quadraplex alternating or parallel operation. No hard water bypass during regeneration. = VIP 2E electronic metered or time clock feature & UL listed. = Solid state multiple metered demand initiated regeneration including rate of flow, resettable totalizing meter S-1202-PVN-VIP2-Q & self-diagnostic status monitoring. NEMA enclosed controller. = VIP 2E - Systems offer individual tank flow meters. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: reclaim. Valve Type Per (grains) Mineral (inches) S-152C-PVN-VIP2-Q , x x41 2,455 S-302C-PVN-VIP2-Q , x66 1, x50 4,135 Plastic Valve S-452C-PVN-VIP2-Q , x66 1, x50 6,095 Nest S-602C-PVN-VIP2-Q , x70 2, x48 7,655 3 S-902E-PVN-VIP2-Q ,000 4x70 2, x48 11,135 3 S-1202E-PVN-VIP2-Q ,200, x70 4,500 5x60 14,040 Note: flow meters supplied with above products are plastic. 3 are insertion type paddle wheel flow meters utilizing PVC saddle. Other materials are available on special order. Ship Wt. Effective 05/01/17 4-6

57 Plastic Valve Nest Epoxy Lined Section 4 Steel Softeners - 18 thru 48 Time Clock PVC Valve Nest Softener Epoxy Lined Steel Simplex TC = Automatic electronic time clock initiated regeneration with Micro T controller. = Hard water bypass during regeneration optional. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. S-302C-PVN-TC-S Valve Type Per (grains) Mineral (inches) S-152C-PVN-TC-S , x x S-302C-PVN-TC-S , x x50 1,075 Plastic Valve S-452C-PVN-TC-S , x x50 1,565 Nest S-602C-PVN-TC-S , x x48 1,955 3 S-902E-PVN-TC-S ,000 4x x48 2,825 3 S-1202E-PVN-TC-S ,200, x x60 3,660 Ship. Wt. Effective 05/01/17 4-7

58 Section 4 Time Clock PVC Valve Nest Softener Epoxy Lined Steel Duplex TC Plastic Valve Nest Epoxy Lined Steel Softeners - 18 thru 48 = Automatic electronic time clock initiated regeneration with Micro T controller. = No hard water bypass during regeneration optional. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Timed brine refill (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes = Spray lined carbon steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. S-302C-PVN-TC-D Valve Type Per (grains) Mineral (inches) S-152C-PVN-TC-D , x x41 1,255 S-302C-PVN-TC-D , x x50 2,095 Plastic Valve S-452C-PVN-TC-D , x x50 3,075 Nest S-602C-PVN-TC-D , x x48 3,855 3 S-902E-PVN-TC-D ,000 4x x48 5,595 3 S-1202E-PVN-TC-D ,200, x x60 7,120 Ship. Wt. Effective 05/01/17 4-8

59 Fleck Top Mount Section 5 Fiberglass Filters Fleck Top Mount Fiberglass Filters *Shown with factory SKID & Interconnecting Plumbing Section 05 Fleck Top Mount Fiberglass Filters Catalog NP Rev. F (05/17) Effective 05/01/17

60 Section 5 Table of Contents Fleck Top Mount Fiberglass Filters Fiberglass Filter Specifications And Design Data Simplex Carbon Filters Simplex Multi-Media Filters Simplex Greensand Plus Filters Duplex Parallel Carbon Filters Duplex Parallel Multi-Media Filters Duplex Parallel Greensand Plus Filters Recommended Media Loading Configuration VIP 1E Carbon Filters, FRP Simplex VIP 1E Carbon Filters, FRP Duplex Alternating VIP 1E Carbon Filters, FRP Duplex Parallel Time Clock Carbon Filters, FRP Simplex Time Clock Carbon Filters, FRP Duplex Parallel VIP 1E Multi-Media Filters, FRP Simplex VIP 1E Multi-Media Filters, FRP Duplex Alternating VIP 1E Multi-Media Filters, FRP Duplex Parallel Time Clock Multi-Media Filters, FRP Simplex Time Clock Multi-Media Filters, FRP Duplex Parallel VIP 1E Greensand Plus Filters, FRP Simplex VIP 1E Greensand Plus Filters, FRP Duplex Alternating VIP 1E Greensand Plus Filters, FRP Duplex Parallel Time Clock Greensand Plus Filters, FRP Simplex Time Clock Greensand Plus Filters, FRP Duplex Parallel Section 05 Fleck Top Mount Fiberglass Filters Catalog NP Rev. F (05/17) Effective 05/01/17

61 Fleck Top Mount Section 5 Fiberglass Filters Fiberglass Filter Specifications and Design Data Simplex Carbon Filters Recommended Flow Rates (2) Mineral Max. Carbon Space Chlorine Organic (4) Drain Media Reqmt Flow Qty. GPM PSI GPM PSI in. LxDxH in. Flow Drop Flow Drop in. GPM Cu. Ft. C-121A x x12x59 C-141A x x14x71 C-161A x x16x72 C-141B x65 1½ x14x71 C-161B x65 1½ x16x72 C-211B x65 1½ x21x75 C-241B x71 1½ x24x82 C-161C x x16x72 C-211C x x21x75 C-241C x x24x87 C-301C x x31x100 C-361C x x37x100 C-361E x x37x104 C-421E x x43x112 C-481E x x49x112 Simplex Multi-Media Filters Recommended Flow Rates (2) Mineral Max. Multi- Space Continuous Peak Drain Media Reqmt s Flow Qty. GPM PSI GPM PSI in. LxDxH in. Flow Drop Flow Drop in. GPM Cu. Ft. M-121A x x12x59 M-141A x x14x71 M-161A x x16x72 M-141B x65 1½ x14x71 M-161B x65 1½ x16x72 M-211B x65 1½ x21x75 M-161C x x16x72 M-211C x x21x75 M-241C x x24x87 M-301C x x31x100 M-361C x x37x100 M-361E x x37x104 Simplex Greensand Plus Filters Recommended Flow Rates (2) Mineral Max. Media Space Continuous Peak Drain Qty. Reqmt s Flow GPM PSI GPM PSI in. Cu. Ft. LxDxH in. Flow Drop Flow Drop in. GPM G-121A x x12x59 G-141A x x14x71 G-161A x x16x72 G-141B x65 1½ x14x71 G-161B x65 1½ x16x72 G-211B x65 1½ x21x75 G-161C x x16x72 G-211C x x21x75 G-241C x x24x87 G-301C x x31x100 G-361C x x37x100 G-361E x x37x104 Notes: (1) Units provided with 7-day time clock and by-pass during reconditioning. Other controls and no water by-pass available. Consult factory. (2) Pressure drops are based on clean bed operation. Pressure drops and weights are estimates. (3) Not including operating and maintenance areas. (4) Standard carbon filter equipment comes with carbon designed for chlorine removal. Organic applications, must be specified up front at quoting stage. Cost adders will apply. Effective 05/01/17 5-1

62 Section 5 Fiberglass Filter Specifications and Design Data (cont d) Duplex Parallel Carbon Filters Recommended Flow Rates (2) (2) Duplex Chlorine Duplex Organic (4) GPM Flow PSI Drop GPM Flow PSI Drop Fleck Top Mount Fiberglass Filters Effective 05/01/ Mineral in. in. Max. Drain Flow GPM Carbon Media Qty. Cu. Ft. Space Reqmt (3) LxDxH in. C-121A x x12x59 C-141A x x14x71 C-161A x x16x72 C-141B x65 1½ x14x71 C-161B x65 1½ x16x72 C-211B x65 1½ x21x75 C-241B x71 1½ x24x82 C-161C x x16x72 C-211C x x21x75 C-241C x x24x87 C-301C x x31x100 C-361C x x37x100 C-361E x x37x104 C-421E x x43x112 C-481E x x49x112 Duplex Parallel Multi-Media Filters s Recommended Flow Rates (2) (2) Duplex Continuous Duplex Peak GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. in. Max. Drain Flow GPM Multi- Media Qty. Cu. Ft. Space Reqmt (3) LxDxH in. M-121A x x12x59 M-141A x x14x71 M-161A x x16x72 M-141B x65 1½ x14x71 M-161B x65 1½ x16x72 M-211B x65 1½ x21x75 M-161C x x16x72 M-211C x x21x75 M-241C x x24x87 M-301C x x31x100 M-361C x x37x100 M-361E x x37x104 Duplex Parallel Greensand Plus Filters s Recommended Flow Rates (2) (2) Duplex Continuous Duplex Peak GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. in. Max. Drain Flow GPM Multi- Media Qty. Cu. Ft. Space Reqmt (3) LxDxH in. G-121A x x12x59 G-141A x x14x71 G-161A x x16x72 G-141B x65 1½ x14x71 G-161B x65 1½ x16x72 G-211B x65 1½ x21x75 G-161C x x16x72 G-211C x x21x75 G-241C x x24x87 G-301C x x31x100 G-361C x x37x100 G-361E x x37x104 Notes: (1) Units provided with 7-day time clock and by-pass during reconditioning. Other controls and no water by-pass available. Consult factory. (2) Pressure drops are based on clean bed operation. Pressure drops and weights are estimates (3) Not including operating and maintenance areas. (4) Standard carbon filter equipment comes with carbon designed for chlorine removal. Organic applications, must be specified up front at quoting stage. Cost adders will apply.

63 Fleck Top Mount Section 5 Fiberglass Filters Fiberglass Filter Specifications and Design Data (cont d) Recommended Media Loading Media Type Gravel Multimedia Greensand Plus Dia Carbon (lbs) Anthracite Sand Garnet Anthracite Greensand Garnet (Cu. Ft.) (lbs) (lbs) (lbs) (lbs) (Cu. Ft.) (lbs) Effective 05/01/17 5-3

64 Section 5 VIP 1E Control Simplex Carbon Filters FRP Simplex = Simplex tank operation. Unfiltered water bypass during backwash. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. Fleck Top Mount Fiberglass Filters C-241C-SNGL Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 C-121A-SNGL x C-141A-SNGL x C-161A-SNGL x C-141B-SNGL x C-161B-SNGL x C-211B-SNGL x C-241B-SNGL x C-161C-SNGL x C-211C-SNGL x C-241C-SNGL x C-301C-SNGL x C-361C-SNGL x7 20 1,200 3 C-361E-SNGL x7 20 1, C-421E-SNGL x7 30 1,930 3 C-481E-SNGL x7 40 2,610 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/17 5-4

65 Fleck Top Mount Section 5 Fiberglass Filters VIP 1E Control Duplex Alternating Carbon Filters FRP ALT 2 = Twin alternating operation. No unfiltered water bypass during backwash. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. C-241C-ALT2 Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 C-121A-ALT x C-141A-ALT x C-161A-ALT x C-141B-ALT x C-161B-ALT x C-211B-ALT x C-241B-ALT x C-161C-ALT x C-211C-ALT x C-241C-ALT x ,340 C-301C-ALT x7 15 1, C-361C-ALT x7 20 2,400 3 C-361E-ALT x7 20 2, C-421E-ALT x7 30 3,860 3 C-481E-ALT x7 40 5,220 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/17 5-5

66 Section 5 VIP 1E Control - Duplex Parallel Carbon Filters FRP PAR 2 = Duplex parallel operation. No unfiltered water bypass during backwash. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = Par 2 Systems offer one single pipe size larger flow meter! = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. Fleck Top Mount Fiberglass Filters C-241C-PAR2 Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 C-121A-PAR x C-141A-PAR x C-161A-PAR x C-141B-PAR x C-161B-PAR x C-211B-PAR x C-241B-PAR x C-161C-PAR x C-211C-PAR x C-241C-PAR x ,340 C-301C-PAR x7 15 1, C-361C-PAR x7 20 2,400 3 C-361E-PAR x7 20 2, C-421E-PAR x7 30 3,860 3 C-481E-PAR x7 40 5,220 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order, see Section 14. Note: Duplex parallel systems have next size larger flow meter to handle double the flow rate. If not required, order duplex alternating system on previous page and program for parallel mode. Effective 05/01/17 5-6

67 Fleck Top Mount Section 5 Fiberglass Filters Time Clock Simplex Carbon Filters FRP Simplex TC = Automatic time clock initiated backwash. = Unfiltered water bypass during backwash. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1ph operation. 7 Day Mech. Time Clock C-241-TC Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 C-121A-TC x C-141A-TC x C-161A-TC x C-141B-TC x C-161B-TC x C-211B-TC x C-241B-TC x C-161C-TC x C-211C-TC x C-241C-TC x C-301C-TC x C-361C-TC x7 20 1,200 3 C-361E-TC x7 20 1, C-421E-TC x7 30 1,930 3 C-481E-TC x7 40 2,610 Effective 05/01/17 5-7

68 Section 5 Time Clock Duplex Carbon Filters FRP Duplex TC Fleck Top Mount Fiberglass Filters = Automatic time clock initiated backwash. = No unfiltered water bypass during regeneration. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1ph operation. 7 Day Mech. Time Clock C-241C-TC-D Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 C-121A-TC-D x C-141A-TC-D x C-161A-TC-D x C-141B-TC-D x C-161B-TC-D x C-211B-TC-D x C-241B-TC-D x C-161C-TC-D x C-211C-TC-D x C-241C-TC-D x ,340 C-301C-TC-D x7 15 1, C-361C-TC-D x7 20 2,400 3 C-361E-TC-D x7 20 2, C-421E-TC-D x7 30 3,860 3 C-481E-TC-D x7 40 5,220 Effective 05/01/17 5-8

69 Fleck Top Mount Section 5 Fiberglass Filters VIP 1E Control Simplex Multi-Media Filters FRP Simplex = Simplex tank operation. Unfiltered water bypass during backwash. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. M-211C-SNGL Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 M-121A-SNGL x M-141A-SNGL x M-161A-SNGL x M-141B-SNGL x M-161B-SNGL x M-211B-SNGL x M-161C-SNGL x M-211C-SNGL x M-241C-SNGL x , M-301C-SNGL x7 15 1,610 M-361C-SNGL x7 20 2, M-361E-SNGL x7 20 2,220 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/17 5-9

70 Section 5 Fleck Top Mount Fiberglass Filters VIP 1E Control - Duplex Alternating Multi-Media Filters FRP ALT 2 = Twin alternating operation. No unfiltered water bypass during backwash. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. M-211C-ALT2 Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 M-121A-ALT x M-141A-ALT x M-161A-ALT x65 4 1, M-141B-ALT x M-161B-ALT x65 4 1, M-211B-ALT x65 6 1,350 M-161C-ALT x65 4 1, M-211C-ALT x65 6 1,340 M-241C-ALT x , M-301C-ALT x7 15 3,220 M-361C-ALT x7 20 4, M-361E-ALT x7 20 4,440 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/

71 Fleck Top Mount Section 5 Fiberglass Filters VIP 1E Control Duplex Parallel Multi-Media Filters FRP PAR 2 = Duplex parallel operation. No unfiltered water bypass during backwash. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = Par 2 Systems offer one single pipe size larger flow meter! = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. M-211C-PAR2 Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 M-121A-PAR x M-141A-PAR x M-161A-PAR x65 4 1, M-141B-PAR x M-161B-PAR x65 4 1, M-211B-PAR x65 6 1,350 M-161C-PAR x65 4 1, M-211C-PAR x65 6 1,340 M-241C-PAR x , M-301C-PAR x7 15 3,220 M-361C-PAR x7 20 4, M-361E-PAR x7 20 4,440 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order, see Section 14. Note: Duplex parallel systems have next size larger flow meter to handle double the flow rate. If not required, order duplex alternating system on previous page and program for parallel mode. Effective 05/01/

72 Section 5 Time Clock Simplex Multi-Media Filters FRP Simplex TC Fleck Top Mount Fiberglass Filters = Automatic time clock initiated backwash. = Unfiltered water bypass during backwash. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1ph operation 7 Day Mech. Time Clock M-211C-TC Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 M-121A-TC x M-141A-TC x M-161A-TC x M-141B-TC x M-161B-TC x M-211B-TC x M-161C-TC x M-211C-TC x M-241C-TC x , M-301C-TC x7 15 1,610 M-361C-TC x7 20 2, M-361E-TC x7 20 2,220 Effective 05/01/

73 Fleck Top Mount Section 5 Fiberglass Filters Time Clock Duplex Multi-Media Filters FRP Duplex TC = Automatic time clock initiated backwash. = No unfiltered water bypass during regeneration. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1ph operation 7 Day Mech. Time Clock M-211-TC-D Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 M-121A-TC-D x M-141A-TC-D x M-161A-TC-D x65 4 1, M-141B-TC-D x M-161B-TC-D x65 4 1, M-211B-TC-D x65 6 1,350 M-161C-TC-D x65 4 1, M-211C-TC-D x65 6 1,340 M-241C-TC-D x , M-301C-TC-D x7 15 3,220 M-361C-TC-D x7 20 4, M-361E-TC-D x7 20 4,440 Effective 05/01/

74 Section 5 VIP 1E Control Simplex Greensand Plus Filters FRP Simplex = Simplex tank operation. Unfiltered water bypass during backwash. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liner for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. Fleck Top Mount Fiberglass Filters G-211C-SNGL Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 G-121A-SNGL x G-141A-SNGL x G-161A-SNGL x G-141B-SNGL x G-161B-SNGL x G-211B-SNGL x G-161C-SNGL x G-211C-SNGL x G-241C-SNGL x , G-301C-SNGL x7 15 1,765 G-361C-SNGL x7 20 2, G-361E-SNGL x7 20 2,960 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/

75 Fleck Top Mount Section 5 Fiberglass Filters VIP 1E Control Duplex Alternating Greensand Plus Filters FRP ALT 2 = Twin alternating operation. No unfiltered water bypass during backwash. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. G-211C-ALT2 Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 G-121A-ALT x G-141A-ALT x G-161A-ALT x G-141B-ALT x G-161B-ALT x65 4 1, G-211B-ALT x65 6 1,520 G-161C-ALT x65 4 1, G-211C-ALT x65 6 1,600 G-241C-ALT x , G-301C-ALT x7 15 3,530 G-361C-ALT x7 20 4, G-361E-ALT x7 20 5,920 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/

76 Section 5 Fleck Top Mount Fiberglass Filters VIP 1E Control Duplex Parallel Greensand Plus Filters FRP PAR 2 = Duplex parallel operation. No unfiltered water bypass during backwash. = VIP 1E electronic metered or time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = Par 2 Systems offer one pipe size larger flow meter! = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. G-211C-PAR2 Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 G-121A-PAR x G-141A-PAR x G-161A-PAR x65 4 1, G-141B-PAR x G-161B-PAR x65 4 1, G-211B-PAR x65 6 1,520 G-161C-PAR x65 4 1, G-211C-PAR x65 6 1,600 G-241C-PAR x , G-301C-PAR x7 15 3,530 G-361C-PAR x7 20 4, G-361E-PAR x7 20 5,920 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order, see Section 14. Note: Duplex parallel systems have next size larger flow meter to handle double the flowrate. If not required, order duplex alternating system on previous page and program for Parallel Mode. Effective 05/01/

77 Fleck Top Mount Section 5 Fiberglass Filters Time Clock Simplex Greensand Plus Filters FRP Simple TC = Automatic time clock initiated backwash. = Unfiltered water bypass during backwash. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1ph operation. 7 Day Mech. Time Clock G-211C-TC Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 G-121A-TC x G-141A-TC x G-161A-TC x G-141B-TC x G-161B-TC x G-211B-TC x G-161C-TC x G-211C-TC x G-241C-TC x , G-301C-TC x7 15 1,765 G-361C-TC x7 20 2, G-361E-TC x7 20 2,960 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Effective 05/01/

78 Section 5 Time Clock Duplex Greensand Plus Filters FRP Duplex TC Fleck Top Mount Fiberglass Filters = Automatic time clock initiated backwash. = No unfiltered water bypass during regeneration. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = ABS tank liners for longer service life. FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1ph operation. 7 Day Mech. Time Clock G-211C-TC-D Fleck Valve Type Mineral (inches) Media Qty. (Cu. Ft.) Ship Wt. 1 G-121A-TC-D x G-141A-TC-D x G-161A-TC-D x65 4 1, G-141B-TC-D x G-161B-TC-D x65 4 1, G-211B-TC-D x65 6 1,520 G-161C-TC-D x65 4 1, G-211C-TC-D x65 6 1,600 G-241C-TC-D x , G-301C-TC-D x7 15 3,530 G-361C-TC-D x7 20 4, G-361E-TC-D x7 20 5,920 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Effective 05/01/

79 Fleck Epoxy Lined Steel Filters Section 6 Fleck Epoxy Lined Steel Filters *Shown with factory SKID & Interconnecting Plumbing Section 06 Fleck Epoxy Lined Steel Filters Catalog NP Rev. F (05/17) Effective 05/01/17

80 Section 6 Fleck Epoxy Lined Steel Filters Table of Contents Lined Steel Filter Specifications And Design Data Simplex Carbon Filters Simplex Multimedia Filters Simplex Greensand Plus Filters Duplex Carbon Filters Duplex Multimedia Filters Duplex Greensand Plus Filters Recommended Media Loading Configuration VIP 1E - Carbon Filters, Epoxy Lined Steel Simplex VIP 1E - Carbon Filters, Epoxy Lined Steel Duplex Alternating VIP 1E - Carbon Filters, Epoxy Lined Steel Duplex Parallel Time Clock Carbon Filters, Epoxy Lined Steel Simplex Time Clock Carbon Filters, Epoxy Lined Steel Duplex VIP 1E - Multi-Media Filters, Epoxy Lined Steel Simplex VIP 1E - Multi-Media Filters, Epoxy Lined Steel Duplex Alternating VIP 1E - Multi-Media Filters, Epoxy Lined Steel Duplex Parallel Time Clock Multi-Media Filters, Epoxy Lined Steel Simplex Time Clock Multi-Media Filters, Epoxy Lined Steel Duplex Parallel VIP 1E Greensand Plus Filters, Epoxy Lined Steel Simplex VIP 1E Greensand Plus Filters, Epoxy Lined Steel Duplex Alternating VIP 1E Greensand Plus Filters, Epoxy Lined Steel Duplex Parallel Time Clock Greensand Plus Filters, Epoxy Lined Steel Simplex Time Clock Greensand Plus Filters, Epoxy Lined Steel Duplex Parallel Section 06 Fleck Epoxy Lined Steel Filters Catalog NP Rev. F (05/17) Effective 05/01/17

81 Fleck Epoxy Lined Steel Filters Section 6 Fleck Lined Steel Filter Specifications and Design Data Simplex Carbon Filters Recommended Flow Rates (2) Mineral Max. Carbon Space Chlorine Organic (4) Drain Media Reqmt Flow Qty. GPM PSI GPM PSI in. LxDxH in. Flow Drop Flow Drop in. GPM Cu. Ft. C-142A x x14x73 C-182A x x18x73 C-142B x x14x73 C-182B x x18x73 C-242B x x24x73 C-183C x x18x79 C-242C x x24x79 C-302C x x30x77 C-362C x x36x81 C-362E x x36x86 C-422E x x42x86 C-482E x x48x86 Simplex Multi-Media Filters Recommended Flow Rates (2) Mineral Max. Multi- Space Continuous Peak Drain Media Reqmt s Flow Qty. GPM PSI GPM PSI in. LxDxH in. Flow Drop Flow Drop in. GPM Cu. Ft. M-142A x x14x73 M-182A x x18x73 M-142B x x14x73 M-182B x x18x73 M-182C x x18x79 M-242C x x24x77 M-302C x x30x77 M-362C x x36x81 M-362E x x36x86 Simplex Greensand Plus Filters Recommended Flow Rates (2) Mineral Max. Media Space Continuous Peak Drain Qty. Reqmt s Flow GPM PSI GPM PSI in. Cu. Ft. LxDxH in. Flow Drop Flow Drop in. GPM G-142A x x14x73 G-182A x x18x73 G-142B x x14x73 G-182B x x18x73 G-182C x x18x79 G-242C x x24x77 G-302C x x30x77 G-362C x x36x81 G-362E x x36x86 NOTES: (1) Units provided with 7-day time clock and by-pass during reconditioning. Other controls and no water by-pass available. Consult factory. (2) Pressure drops are based on clean bed operation. Pressure drops and weights are estimates. (3) Not including operating and maintenance areas. (4) Standard carbon filter equipment comes with carbon designed for chlorine removal. Organic applications, must be specified up front at quoting stage. Cost adders will apply. Effective 05/01/17 6-1

82 Section 6 Fleck Epoxy Lined Steel Filters Fleck Lined Steel Filter Specifications and Design Data Duplex Carbon Filters Recommended Flow Rates (2) Mineral Max. Carbon Space Chlorine Organic (4) Drain Media Reqmt Flow Qty. GPM PSI GPM PSI in. LxDxH in. Flow Drop Flow Drop in. GPM Cu. Ft. C-142A x x14x73 C-182A x x18x73 C-142B x x14x73 C-182B x x18x73 C-242B x x24x73 C-183C x x18x79 C-242C x x24x79 C-302C x x30x77 C-362C x x36x81 C-362E x x36x86 C-422E x x42x86 C-482E x x48x86 Duplex Multi-Media Filters Recommended Flow Rates (2) Mineral Max. Multi- Space Continuous Peak Drain Media Reqmt s Flow Qty. GPM PSI GPM PSI in. LxDxH in. Flow Drop Flow Drop in. GPM Cu. Ft. M-142A x x14x73 M-182A x x18x73 M-142B x x14x73 M-182B x x18x73 M-182C x x18x79 M-242C x x24x77 M-302C x x30x77 M-362C x x36x81 M-362E x x36x86 Duplex Greensand Plus Filters Recommended Flow Rates (2) Mineral Max. Media Space Continuous Peak Drain Qty. Reqmt s Flow GPM PSI GPM PSI in. Cu. Ft. LxDxH in. Flow Drop Flow Drop in. GPM G-142A x x14x73 G-182A x x18x73 G-142B x x14x73 G-182B x x18x73 G-182C x x18x79 G-242C x x24x77 G-302C x x30x77 G-362C x x36x81 G-362E x x36x86 NOTES: (1) Units provided with 7-day time clock and by-pass during reconditioning. Other controls and no water by-pass available. Consult factory. (2) Pressure drops are based on clean bed operation. Pressure drops and weights are estimates. (3) Not including operating and maintenance areas. (4) Standard carbon filter equipment comes with carbon designed for chlorine removal. Organic applications, must be specified up front at quoting stage. Cost adders will apply. Effective 05/01/17 6-2

83 Fleck Epoxy Lined Steel Filters Section 6 Fleck Lined Steel Filter Specifications and Design Data Recommended Media Loading Media Type Multimedia Greensand Plus Dia Gravel (lbs) Carbon (Cu. Ft.) Anthracite Sand Garnet Anthracite Greensand Garnet (Lbs) (Lbs) (Lbs) (lbs) (Cu. Ft.) (Lbs) Effective 05/01/17 6-3

84 Section 6 Fleck Epoxy Lined Steel Filters VIP 1E Control - Simplex Carbon Filters Epoxy Lined Steel Simplex = Simplex tank operation. Unfiltered water bypass during backwash. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 C-142A-SNGL x C-182A-SNGL x C-142B-SNGL x C-182B-SMGL x C-242B-SNGL x C-182C-SNGL x C-242C-SNGL x C-302C-SNGL x , C-362C-SNGL x ,390 3 C-362E-SNGL x , C-422E-SNGL x ,010 3 C-482E-SNGL x ,605 S-302C-SNGL Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/17 6-4

85 Fleck Epoxy Lined Steel Filters Section 6 VIP 1E Control Duplex Alternating Carbon Filters Epoxy Lined Steel ALT 2 = Duplex alternating operation. No unfiltered water bypass during backwash. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. C-242C-ALT2 Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 C-142A-ALT x C-182A-ALT x C-142B-ALT x C-182B-ALT x C-242B-ALT x ,540 C-182C-ALT x C-242C-ALT x ,560 C-302C-ALT x , C-362C-ALT x ,780 3 C-362E-ALT x , C-422E-ALT x ,020 3 C-482E-ALT x ,210 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/17 6-5

86 Section 6 Fleck Epoxy Lined Steel Filters VIP 1E Control Duplex Parallel Carbon Filters Epoxy Lined Steel PAR 2 = Duplex parallel operation. No unfiltered water bypass during backwash. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = PAR 2 Systems offer one single pipe size larger flow meter! = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 C-142A-PAR x C-182A-PAR x C-142B-PAR x C-182B-PAR x C-242B-PAR x ,540 C-182C-PAR x C-242C-PAR x ,560 C-302C-PAR x , C-362C-PAR x ,780 3 C-362E-PAR x , C-422E-PAR x ,020 3 C-482E-PAR x ,210 C-242C-PAR2 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Note: Duplex parallel systems have next size larger flow meter to handle double the flow rate. If not required, order duplex alternating system on previous page and program for parallel mode. Effective 05/01/17 6-6

87 Fleck Epoxy Lined Steel Filters Section 6 Time Clock Simplex Carbon Filters Epoxy Lined Steel Simplex TC = Automatic time clock initiated backwash. Unfiltered water bypass during backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH (24 volt AC operation). 7 day Mech. Time Clock C-242C-TC Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 C-142A-TC x C-182A-TC x C-142B-TC x C-182B-TC x C-242B-TC x C-182C-TC x C-242C-TC x C-302C-TC x , C-362C-TC x ,390 3 C-362E-TC x , C-422E-TC x ,010 3 C-482E-TC x ,605 Effective 05/01/17 6-7

88 Section 6 Fleck Epoxy Lined Steel Filters Time Clock Duplex Carbon Filters Epoxy Lined Steel Duplex TC = Automatic time clock initiated backwash. Unfiltered water bypass during backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH (24 volt AC operation). 7 day Mech. Time Clock C-242C-TC-D Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 C-142A-TC-D (2) x C-182A-TC-D (2) x C-142B-TC-D (2) x C-182B-TC-D (2) x C-242B-TC-D (2) x ,540 C-182C-TC-D (2) x C-242C-TC-D (2) x ,560 C-302C-TC-D (2) x , C-362C-TC-D (2) x ,780 3 C-362E-TC-D (2) x , C-422E-TC-D (2) x ,020 3 C-482E-TC-D (2) x ,210 Effective 05/01/17 6-8

89 Fleck Epoxy Lined Steel Filters Section 6 VIP 1E Control Simplex Multi-Media Filters Epoxy Lined Steel Simplex = Simplex delayed or immediate regeneration. Unfiltered water bypass during backwash. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 M-142A-SNGL x M-182A-SNGL x M-142B-SNGL x M-182B-SNGL x M-182C-SNGL x M-242C-SNGL x , M-302C-SNGL x ,795 M-362C-SNGL x , M-362E-SNGL x ,410 M-242C-SNGL Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/17 6-9

90 Section 6 Fleck Epoxy Lined Steel Filters VIP 1E Control Duplex Alternating Multi-Media Filters Epoxy Lined Steel ALT2 = Duplex alternating operation. No unfiltered water bypass during backwash. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, resettable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 M-142A-ALT x M-182A-ALT x66 5 1, M-142B-ALT x M-182B-ALT x66 5 1, M-182C-ALT x66 5 1,250 M-242C-ALT x , M-302C-ALT x ,590 M-362C-ALT x , M-362E-ALT x ,820 M-242C-ALT2 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/

91 Fleck Epoxy Lined Steel Filters Section 6 VIP 1E Control Duplex Parallel Multi-Media Filters Epoxy Lined Steel PAR2 = Duplex parallel operation. No unfiltered water bypass during backwash. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, resettable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = PAR 2 Systems offer one single pipe size larger flow meter! = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. M-242C-PAR2 Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 M-142A-PAR x M-182A-PAR x66 5 1, M-142B-PAR x M-182B-PAR x66 5 1, M-182C-PAR x66 5 1,250 M-242C-PAR x , M-302C-PAR x ,590 M-362C-PAR x , M-362E-PAR x ,820 Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Note: Duplex parallel systems have next size larger flow meter to handle double the flow rate. If not required, order duplex alternating system on previous page and program for parallel mode. Effective 05/01/

92 Section 6 Fleck Epoxy Lined Steel Filters Time Clock Simplex Multi-Media Filters Epoxy Lined Steel Simplex TC = Automatic time clock initiated backwash. Unfiltered water bypass during backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH (24 volt AC operation). 7 day Mech. Time Clock M-242C-TC Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 M-142A-TC x M-182A-TC x M-142B-TC x M-182B-TC x M-182C-TC x M-242C-TC x , M-302C-TC x ,795 M-362C-TC x , M-362E-TC x ,410 Effective 05/01/

93 Fleck Epoxy Lined Steel Filters Section 6 Time Clock Duplex Multi-Media Filters Epoxy Lined Steel Duplex TC = Automatic time clock initiated backwash. Unfiltered water bypass during backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH (24 volt AC operation). 7 day Mech. Time Clock Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 M-142A-TC (2) x M-182A-TC (2) x M-142B-TC (2) x M-182B-TC (2) x M-182C-TC (2) x M-242C-TC (2) x , M-302C-TC (2) x ,795 M-362C-TC (2) x , M-362E-TC (2) x ,410 Effective 05/01/

94 Section 6 Fleck Epoxy Lined Steel Filters VIP 1E Control Simplex Greensand Plus Filters Epoxy Lined Steel Simplex = Simplex delayed or immediate regeneration. Unfiltered water bypass during backwash. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 G-142A-SNGL x G-182A-SNGL x G-142B-SNGL x G-182B-SNGL x G-182C-SNGL x G-242C-SNGL x , G-302C-SNGL x ,950 G-362C-SNGL x , G-362E-SNGL x ,150 G-242C-SNGL Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/

95 Fleck Epoxy Lined Steel Filters Section 6 VIP 1E Control - Duplex Alternating Greensand Plus Filters Epoxy Lined Steel ALT2 = Duplex alternating operation. No unfiltered water bypass during backwash. = VIP 1E electronic time clock feature & UL listed. Solid state single metered demand initiated backwash including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. G-242C-ALT2 Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 G-142A-ALT x G-182A-ALT x66 5 1, G-142B-ALT x G-182B-ALT x66 5 1, G-182C-ALT x66 5 1,320 G-242C-ALT x , G-302C-ALT x ,900 G-362C-ALT x , G-362E-ALT x ,300 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Effective 05/01/

96 Section 6 Fleck Epoxy Lined Steel Filters VIP 1E Control Duplex Parallel Greensand Plus Filters Epoxy Lined Steel PAR2 = Duplex parallel operation. No unfiltered water bypass during backwash. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated backwash including rate of flow, resettable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = PAR 2 Systems offer one single pipe size larger flow meter! = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. G-242C-PAR2 Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 G-142A-PAR x G-182A-PAR x66 5 1, G-142B-PAR x G-182B-PAR x66 5 1, G-182C-PAR x66 5 1,320 G-242C-PAR x , G-302C-PAR x ,900 G-362C-PAR x , G-362E-PAR x ,300 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Note: 1, 1.5 and flow meters supplied with above products are plastic. 3 and 4 are insertion type paddle wheel flow meters utilizing copper tees. Other materials are available on special order. Note: Duplex parallel systems have next size larger flow meter to handle double the flow rate. If not required, order duplex alternating system on previous page and program for parallel mode. Effective 05/01/

97 Fleck Epoxy Lined Steel Filters Section 6 Time Clock Simplex Greensand Plus Filters Epoxy Lined Steel Simplex TC = Automatic time clock initiated backwash. Unfiltered water bypass during backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. 7 day Mech. Time Clock G-242C-TC Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 G-142A-TC x G-182A-TC x G-142B-TC x G-182B-TC x G-182C-TC x G-242C-TC x G-302C-TC x ,145 G-362C-TC x , G-362E-TC x ,440 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Effective 05/01/

98 Section 6 Fleck Epoxy Lined Steel Filters Time Clock Duplex Greensand Plus Filters Epoxy Lined Steel Duplex TC = Automatic time clock initiated backwash. Unfiltered water bypass during backwash. = Lead-free brass multi-port control valves with self-cleaning, hydraulically balanced positive acting piston. = Spray lined tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. 7 day Mech. Time Clock Fleck Valve Type Mineral (inches) Media Qty. per (Cu.Ft.) Ship Wt. 1 G-142A-TC (2) x G-182A-TC (2) x G-142B-TC (2) x G-182B-TC (2) x G-182C-TC (2) x G-242C-TC (2) x G-302C-TC (2) x ,145 G-362C-TC (2) x , G-362E-TC (2) x ,440 G-242C-TC-D Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Effective 05/01/

99 Plastic Valve Nest Epoxy Lined Section 7 Steel Filters - 18 thru 48 Plastic Valve Nest Epoxy Lined Steel Filters 18 thru 48 Section 07 PVC Valve Nest Steel Filters Catalog NP Rev. F (05/17) Effective 05/01/17

100 Section 7 Table of Contents Plastic Valve Nest Epoxy Lined Steel Filters - 18 thru 48 PVC Valve Nest Filter Specifications And Design Data Simplex Carbon Filters - Epoxy Lined Steel s Simplex Multimedia Filters - Epoxy Lined Steel s Simplex Greensand Filters - Epoxy Lined Steel s Duplex Carbon Filters - Epoxy Lined Steel s Duplex Multimedia Filters - Epoxy Lined Steel s Duplex Greensand Plus Filters - Epoxy Lined Steel s Recommended Media Loading Configuration Time Clock VN Carbon Filters, Epoxy Lined Simplex Time Clock VN Carbon Filters, Epoxy Lined Duplex Time Clock VN Multimedia Filters, Epoxy Lined Simplex Time Clock VN Multimedia Filters, Epoxy Lined Duplex Time Clock VN Greensand Plus Filters, Epoxy Lined Simplex Time Clock VN Greensand Plus Filters, Epoxy Lined Duplex Section 07 PVC Valve Nest Steel Filters Catalog NP Rev. F (05/17) Effective 05/01/17

101 Plastic Valve Nest Epoxy Lined Section 7 Steel Filters - 18 thru 48 Plastic Valve Nest Filter Specs and Design Data Simplex Carbon Filters Epoxy Lined Steel s GPM Flow Recommended Flow Rates (2) Chlorine Organic (4) PSI Drop GPM Flow PSI Drop Mineral in. in. Max. Drain Flow GPM Carbon Media Qty. Cu. Ft. Space Reqmt (3) LxDxH in. C-182C-PVN x x18x72 C-242C-PVN x x24x72 C-302C-PVN x x30x72 C-362C-PVN x x36x78 C-422E-PVN x x42x78 C-482E-PVN x x48x78 Simplex Multimedia Filters Epoxy Lined Steel s Recommended Flow Rates (2) Continuous Peak GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. in. Max. Drain Flow GPM Multi- Media Qty. Cu. Ft. Space Reqmt (3) LxDxH in. M-182C-PVN x x18x72 M-242C-PVN x x24x72 M-302C-PVN x x30x72 M-362E-PVN x x36x78 M-422E-PVN x x42x78 M-482E-PVN x x48x78 Simplex Greensand Plus Filters Epoxy Lined Steel s Recommended Flow Rates (2) Continuous Peak GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. in. Max. Drain Flow GPM Media Qty. Cu. Ft. Space Reqmt (3) LxDxH in. G-182C-PVN x x18x72 G-242C-PVN x x24x72 G-302C-PVN x x30x72 G-362E-PVN x x36x78 G-422E-PVN x x42x78 G-482E-PVN x x48x78 NOTES: 1. Units provided with 7-day time clock and by-pass during reconditioning. Other controls and no water by-pass available. Consult factory. 2. Pressure drops are based on clean bed operation. Pressure drops and weights are estimates. 3. Not including operating and maintenance areas. 4. Standard carbon filter equipment comes with carbon designed for chlorine removal. Organic applications, must be specified up front at quoting stage. Cost adders apply. Effective 05/01/17 7-1

102 Section 7 Plastic Valve Nest Epoxy Lined Steel Filters - 18 thru 48 Plastic Valve Nest Filter Specs and Design Data (cont d) Duplex Carbon Filters Epoxy Lined Steel s GPM Flow Recommended Flow Rates (2) Chlorine Organic (4) PSI Drop GPM Flow PSI Drop Mineral in. in. Max. Drain Flow GPM Carbon Media Qty. Cu. Ft per tank Space Reqmt (3) LxDxH in. C-182C-PVN x x18x72 C-242C-PVN x x24x72 C-302C-PVN x x30x72 C-362C-PVN x x36x78 C-422E-PVN x x42x78 C-482E-PVN x x48x78 Duplex Multimedia Filters Epoxy Lined Steel s Recommended Flow Rates (2) Continuous Peak GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. in. Max. Drain Flow GPM Multi- Media Qty. Cu. Ft. per tank Space Reqmt (3) LxDxH in. M-182C-PVN x x18x72 M-242C-PVN x x24x72 M-302C-PVN x x30x72 M-362E-PVN x x36x78 M-422E-PVN x x42x78 M-482E-PVN x x48x78 Duplex Greensand Plus Filters Epoxy Lined Steel s Recommended Flow Rates (2) Continuous Peak GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. in. Max. Drain Flow GPM Media Qty. Cu. Ft. per tank Space Reqmt (3) LxDxH in. G-182C-PVN x x18x72 G-242C-PVN x x24x72 G-302C-PVN x x30x72 G-362E-PVN x x36x78 G-422E-PVN x x42x78 G-482E-PVN x x48x78 NOTES: 1. Units provided with 7-day time clock and by-pass during reconditioning. Other controls and no water by-pass available. Consult factory. 2. Pressure drops are based on clean bed operation. Pressure drops and weights are estimates. 3. Not including operating and maintenance areas. 4. Standard carbon filter equipment comes with carbon designed for chlorine removal. Organic applications, must be specified up front at quoting stage. Cost adders apply. Effective 05/01/17 7-2

103 Plastic Valve Nest Epoxy Lined Section 7 Steel Filters - 18 thru 48 Plastic Valve Nest Filter Specs and Design Data (cont d) Recommended Media Loading Dia Gravel (lbs) Carbon (Cu. Ft.) Anthracite (lbs) Multimedia Sand (lbs) Media Type Garnet (lbs) Anthracite (lbs) Greensand Plus Greensand (Cu. Ft.) Garnet (lbs) Effective 05/01/17 7-3

104 Section 7 Plastic Valve Nest Epoxy Lined Steel Filters - 18 thru 48 Time Clock Micro-T Control Plastic Valve Nest Carbon Filters Epoxy Lined Steel Simplex TC = Automatic Micro T electronic time clock initiated backwash. = Unfiltered water bypass during backwash. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Spray lined steel tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: VIP 1E or VIP 2E demand initiated backwash controllers available. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. Mineral (inches) Media Qty. (Cu. Ft.) C-422E-PVN Ship Wt. C-182C-PVN-TC x C-242C-PVN-TC x C-302C-PVN-TC x ,385 C-362C-PVN-TC x ,170 3 C-422E-PVN-TC x ,810 3 C-482E-PVN-TC x ,600 Effective 05/01/17 7-4

105 Plastic Valve Nest Epoxy Lined Section 7 Steel Filters - 18 thru 48 Time Clock Micro T Control Plastic Valve Nest Carbon Filters Epoxy Lined Steel Duplex TC = Automatic Micro T electronic time clock initiated backwash. = No unfiltered raw water bypass during regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Spray lined steel tanks with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: VIP 1E or VIP 2E demand initiated backwash controllers available. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. C-422E-PVN-D Mineral (inches) Media Qty. per (Cu. Ft.) Ship Wt. C-182C-PVN-TC-D x60 5 1,030 C-242C-PVN-TC-D x ,870 C-302C-PVN-TC-D x ,770 C-362C-PVN-TC-D x ,340 3 C-422E-PVN-TC-D x ,620 3 C-482E-PVN-TC-D x ,200 Effective 05/01/17 7-5

106 Section 7 Plastic Valve Nest Epoxy Lined Steel Filters - 18 thru 48 Time Clock Micro T Control Plastic Valve Nest Multimedia Filters Epoxy Lined Steel Simplex TC = Automatic Micro T electronic time clock initiated backwash. = Unfiltered raw water bypass during regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Spray lined steel tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: VIP 1E or VIP 2E demand initiated backwash controllers available. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. M-422E-PVN Mineral (inches) Media Qty. per (Cu. Ft.) Ship Wt. M-182C-PVN-TC x M-242C-PVN-TC x ,385 M-302C-PVN-TC x ,062 3 M-362E-PVN-TC x ,070 3 M-422E-PVN-TC x ,260 3 M-482E-PVN-TC x ,400 Effective 05/01/17 7-6

107 Plastic Valve Nest Epoxy Lined Section 7 Steel Filters - 18 thru 48 Time Clock Micro T Control Plastic Valve Nest Multimedia Filters Epoxy Lined Steel Duplex TC = Automatic Micro T electronic time clock initiated backwash. = No unfiltered water bypass during regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Spray lined steel tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: VIP 1E or VIP 2E demand initiated backwash controllers available. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. M-422E-PVN-D Mineral (inches) Media Qty. per (Cu. Ft.) Ship Wt. M-182C-PVN-TC-D x60 5 1,480 M-242C-PVN-TC-D x ,770 M-302C-PVN-TC-D x ,124 3 M-362E-PVN-TC-D x ,140 3 M-422E-PVN-TC-D x ,520 3 M-482E-PVN-TC-D x ,800 Effective 05/01/17 7-7

108 Section 7 Plastic Valve Nest Epoxy Lined Steel Filters - 18 thru 48 Time Clock Micro T Control Plastic Valve Nest Greensand Plus Filters Epoxy Lined Steel Simplex TC = Automatic Micro T electronic time clock initiated backwash. = Unfiltered water bypass during regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Spray lined steel tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: VIP 1E or VIP 2E demand initiated backwash controllers available. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. G-422E-PVN Mineral (inches) Media Qty. per (Cu. Ft.) Ship Wt. G-182C-PVN-TC x G-242C-PVN-TC x ,535 G-302C-PVN-TC x ,284 3 G-362E-PVN-TC x ,495 3 G-422E-PVN-TC x ,710 3 G-482E-PVN-TC x ,000 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Effective 05/01/17 7-8

109 Plastic Valve Nest Epoxy Lined Section 7 Steel Filters - 18 thru 48 Time Clock Micro T Control Plastic Valve Nest Greensand Plus Filters Epoxy Lined Steel Duplex TC = Automatic Micro T electronic time clock initiated backwash. = No filtered water bypass during regeneration. = Schedule 80 PVC valve nest header design, utilizing composite diaphragm valves for corrosion resistance. = Lined steel tank with epoxy coated int/ext for corrosion resistance. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: VIP 1E or VIP 2E demand initiated backwash controllers available. = Optional: Differential pressure backwash feature. = Optional: VIP 2E triplex and/or quadraplex units available. G-422E-PVN-D Mineral (inches) Media Qty. per (Cu. Ft.) Ship Wt. G-182C-PVN-TC-D x60 5 1,630 G-242C-PVN-TC-D x ,070 G-302C-PVN-TC-D x ,570 3 G-362E-PVN-TC-D x ,990 3 G-422E-PVN-TC-D x ,420 3 G-482E-PVN-TC-D x ,000 Manganese treated greensand plus must be supplied with sodium hypochlorite or potassium permanganate on a continuous basis. Normally a chemical feed pump is used for this purpose. Chemical is pumped into the raw water prior to contact with the greensand filter. Contact our commercial support department for help with sizing and pricing of chemical pumps. Effective 05/01/17 7-9

110

111 Reverse Osmosis Systems Section 8 Reverse Osmosis Systems Section 8 Reverse Osmosis Systems Catalog NP Rev. F (05/17) Effective 05/01/17

112 Section 8 Reverse Osmosis Systems Table of Contents Reverse Osmosis Systems Specifications And Design Data HVE Series - 2,000-10,800 GPD MVE Series ,000 GPD LVE Series GPD Reverse Osmosis Systems Configurations HVE Series Best 2,000 To 14,400 GPD HVE Series Better 2,000 To 14,400 GDP MVE Series Better 500 To 2,000 GDP LVE Series Better 250 To 500 GDP REVERSE OSMOSIS ATMOSPHERIC DELIVERY SYSTEMS Reverse Osmosis Components Pressure Kits RO Accessories Section 8 Reverse Osmosis Systems Catalog NP Rev. F (05/17) Effective 05/01/17

113 Reverse Osmosis Systems Section 8 Reverse Osmosis Units Specifications and Design Data ECI HVE Series 2,000 14,400 GPD ( GPM) R1F40 R2F40 R3F40 R4F40 R5F40 R6F40 R8F40 Product Flow (1) (2) GPM GPD 2,000 3,900 5,600 7,500 9,500 10,800 14,400 Feed Flow (GPM) Reject Flow (GPM) Recycle Yes Yes Yes Yes Yes Yes Yes Rejection 98% 98% 98% 98% 98% 98% 98% Recovery Range 18 75% 32 75% 42 75% 34 75% 37 75% 42 75% 50 75% Membrane 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 4 x 40 Vessel 1M 1M 1M 1M 1M 1M 1M Array 1 1:1 1:1:1 2:1:1 2:2:1 2:2:1:1 3:3:2 No. of Membranes Prefilter In Feed Pkg FNPT 0.75 FNPT 0.75 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Feed Pkg FNPT 0.75 FNPT 0.75 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Feed Pkg FNPT 0.75 FNPT 0.75 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Product Pkg Tube Tube Tube 0.5 Tube 0.5 Tube 0.5 Tube 0.5 Tube Product Pkg FNPT 0.5 FNPT 0.5 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Product - Pkg FNPT 0.75 FNPT 0.75 FNPT 0.75 FNPT 0.75 FNPT 0.75 FNPT 0.75 FNPT Reject Pkg MNPT MNPT MNPT 0.5 MNPT 0.5 MNPT 0..5 MNPT 0.5 FNPT Reject Pkg FNPT 0.5 FNPT 0.5 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Reject Pkg FNPT 0.5 FNPT 0.5 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT 1.0 FNPT Feed Pressure (psig) Pump HP 3/4 3/4 3/ Power 220V/60Hz/ 1 ph 220V/60Hz/ 1 ph 220V/60Hz/ 1 ph 220V/60Hz/ 1 ph 220V/60Hz/ 1 ph 220V/60Hz/ 1 ph 220V/60Hz/ 1 ph Amps Dimensions (LxDxH) (3) 26 x 16 x x 16 x x 16 x x 16 x x 16 x x 16 x x 21 x 54 Notes: (1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, ph 2-11 and temperature 77 O F. (2) System flows are design parameters. (3) All dimensions approximate. Additional space required for maintenance. Effective 05/01/17 8-1

114 Section 8 Reverse Osmosis Systems Reverse Osmosis Units Specifications and Design Data ECI MVE Series 500 2,000 GPD R2E12 R4E12 R4E12P Product Flow (1) (2) GPM GPD 500 1,000 2,000 Feed Flow (GPM) Reject Flow (GPM) Recycle No No Yes Rejection 95% 95% 95% Max Recovery 75% 75% 75% Membrane x 1 3 x 1 3 x 1 Vessel 3 x 1 3 x 1 3 x 1 No. of Membranes Prefilter GAC/Sediment GAC/Sediment GAC/Sediment In Feed 1/ NPT 1/ NPT 1/ NPT Product 3/8 3/8 3/8 Reject 3/8 3/8 3/8 Feed Pressure (psig) PSI Pump HP - - 1/3 Power 110V, 1 ph Amps 4 4 Dimensions (LxDxH) (3) 21 x 12.5 x 30.9 Notes: (1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, ph 3-11 and temperature 77 O F. (2) System flows are design parameters. (3) All dimensions approximate. Additional 18 space required around system for maintenance. Effective 05/01/17 8-2

115 Reverse Osmosis Systems Section 8 Reverse Osmosis Units Specifications and Design Data ECI LVE Series GPD R1E12 R2E12 Product Flow (1) (2) GPM GPD Feed Flow (GPM).35.7 Reject Flow (GPM) Rejection 95% 95% Max Recovery 75% 75% Membrane 3 x 1 3 x 1 Vessel 3 x 1 3 x 1 No. of Membranes 1 2 Prefilter GAC/Sediment GAC/Sediment In Feed 3/8 3/8 Product 3/8 3/8 Reject 3/8 3/8 Feed Pressure (psig) Power PSI 24VDC Watts 25 Dimensions (LxDxH) (3) 14 x 6.06 x Notes: (1) Based upon feed water: SDI<3, free chlorine 0.0 mg/l maximum, ph 3-11 and temperature 77 O F. (2) System flows are design parameters. (3) All dimensions approximate. Additional 18 space required around system for maintenance. (4) Membrane performance 70 PSI, 77 o F, 40% recovery 250ppm NaCL Effective 05/01/17 8-3

116 Section 8 Reverse Osmosis Systems Reverse Osmosis Systems HVE Series 2,000 to 14,400 GPD Best = 4 x 40 low-energy TFC membranes. = Smooth, quiet operating stainless steel, multi-stage centrifugal pumps with plastic impellers. = 3/4 or 2 HP 230/60 Hz/1 ph motors providing up to 185 PSI pressure (1 inlet) with 5-micron filter. = Single power connection for all controls, switches, and solenoid valves. = Stainless steel membrane housings. = Stainless steel solenoid valves. = Heavy-duty, powder coated steel frame for durability and rust resistance. = Pretreatment lockout. = Low level connections. = Low-pressure protection. = Auto re-start after shutdown. = Waste recycle. = Product and waste flow meter. = Product TDS meter. = All systems are fully tested and shipped fully assembled. Package Options: = Auto flush. = Stainless steel frame. R4F40-BEST Nominal GPD Membranes No. & HP Ship Wt. 2,000 R1F40-BEST x 40 3/ ,900 R2F40-BEST x 40 3/ ,600 R3F40-BEST x 40 3/ ,500 R4F40-BEST x ,500 R5F40-BEST x ,800 R6F40-BEST x ,400 R8F40-BEST x Effective 05/01/17 8-4

117 Reverse Osmosis Systems Section 8 Reverse Osmosis Systems HVE Series 2,000 to 14,400 GPD Better Standard = 4 x 40 low-energy TFC membranes. = Smooth, quiet operating stainless steel, multi-stage centrifugal pumps with plastic impellers. = 3/4 or 2 HP 230/60 Hz/1 ph motors providing up to 185 PSI pressure (1 inlet) with 5-micron filter. = Single power connection for all controls, switches, and solenoid valves. = Stainless steel membrane housings. = Stainless steel solenoid valves. = Heavy-duty, powder coated steel frame for durability and rust resistance. = Pretreatment lockout. = Low level connections. = Low-pressure protection. = Auto re-start after shutdown. = Waste recycle. = Product and waste flow meter. = All systems are fully tested and shipped fully assembled. Package Options: = Auto flush. = Stainless Steel frame. R2F40-BETTER Nominal GPD Membranes No. & HP Ship Wt. 2,000 R1F40-BETTER x 40 3/ ,900 R2F40-BETTER x 40 3/ ,600 R3F40-BETTER x 40 3/ ,500 R4F40-BETTER x ,500 R5F40-BETTER x ,800 R6F40-BETTER x ,400 R8F40-BETTER x Effective 05/01/17 8-5

118 Section 8 Reverse Osmosis Systems Reverse Osmosis Systems MVE Series 500 to 2,000 GPD Better = Wall mount or floor/shelf mount. = Zero clearance required on bottom and sides. = All components can be serviced from front or top of unit. = Pretreatment lockout. = 3 x 1 XLP low pressure membranes. = 1/3 HP 110/60 Hz/1-phase motors providing up to 125 PSI pressure. = Easy to operate filter in, filter out, pump and product pressure gauges. = Single power connection for all controls, switches, and solenoid valves. = Carbon filter and 5-micron sediment filter. = Smooth, quiet operating, brass vane-type pump (2,000 GPD unit only). = Standard plumbing connections - 1/ Inlet, 3/8 permeate and drain connections. = Stainless steel solenoid valves. = Heavy-duty, powder coated steel cabinet for durability and rust resistance. = All systems are fully tested and shipped fully assembled. R4E12P-BETTER Nominal GPD Membranes No. & (vessel) HP Ship Wt. 500 MVE-R2E12-BETTER x 12 N/A 75 1,000 MVE-R4E12-BETTER x12 N/A 80 2,000 MVE-R4E12P-BETTER x 12 1/3 100 Effective 05/01/17 8-6

119 Reverse Osmosis Systems Section 8 Reverse Osmosis Systems LVE Series 250 to 500 GPD Better = Compact design - Wall mounted. = Pretreatment lockout - Disables RO production during regeneration. = Single power connection - For all controls, switches and solenoid valves. = Simple, easy to read gauges - Filter in, filter out, and product pressure gauges. = High flow, low-pressure XLP membrane % maximum TDS rejection. Stands up to the most rugged of feed water conditions. = Carbon and sediment filter included - Provides basic pretreatment, dechlorination and sediment removal down to 5 microns. = Standard plumbing connection - Uses 3/8 inlet, 3/8 permeate and drain connections. = Heavy duty, powder-coated steel cabinet for durability and rust resistance. R2E12-BETTER Nominal GPD Membranes No. & (vessel) HP Ship Wt. 250 LVE-R1E12-BETTER x12 N/A LVE-R2E12-BETTER x 12 N/A 80 Effective 05/01/17 8-7

120 Section 8 Reverse Osmosis Systems Reverse Osmosis Atmospheric Delivery System = Designed for easy transportation, installation and service storage tank designed to fit through most doorways. = Sealed tank with Fact filter ensures no air contaminant pollutes the water in the tank. = Float for RO control, installed. = Float for low level pump protection, installed protects pump from running without water. = Compact Grundfos MQ series pump easy to operate, low-noise and includes a dry-running protection. = UV light, installed lamp shipped separately. = Outlet pressure gauge, sample valve and check valve, installed for easier installation and service. = Quick plug in electrical connections for: - Float switches - Pump - Optional automatic bypass if tank reaches low level = Electrical requirements - 120V, 15 AMP. ROAD 321 Nominal Installation Ship Wt. 300 ROAD x96 x ROAD x109 x Effective 05/01/17 8-8

121 Reverse Osmosis Systems Section 8 Pressure Kits Pressure Package, PSC-48 Pressure Package, PSC-80 Pressure Package, PSC-119 Description Pressure Package, PSC Includes: Pressure, 21 x Pressure Switch Pressure Gauge, PSI Check Valve, 1 Spring Check Ball Valve, 1 SCH80 PVC Union Bushing, PVC 1.25 x1 TxT Instruction Sheet Description Pressure Package, PSC Includes: Pressure, 21 x Pressure Switch Pressure Gauge, PSI Check Valve, 1 Spring Check Ball Valve, 1 SCH80 PVC Union Bushing, PVC 1.25 x1 TxT Instruction Sheet Description Pressure Package, PSC Includes: Pressure, 24 x Pressure Switch Pressure Gauge, PSI Check Valve, 1 Spring Check Ball Valve, 1 SCH80 PVC Union Bushing, PVC 1.25 x1 TxT Instruction Sheet Effective 05/01/17 8-9

122 Section 8 Reverse Osmosis Systems Reverse Osmosis Accessories Description Pressure, 20 x40 35 Gal. Nominal Pressure, 24 x46 60 Gal. Nominal Pressure, 24 x Gal. Nominal Storage, 300 Gal. Doorway w 1.25 Lower Fitting Storage, 500 Gal. Doorway w 1.25 Lower Fitting NC Pressure Switch, PSI NC Float Switch, RO Shut Off with Open Wires - SPDT Float Switch, RO Shut Off with 110V Plug - RO Shut-off Float Switch, RO Shut Off with 220V - RO Shut-off Check Valve, 1 Spring Check Ball Valve, 1 SCH80 PVC Union Pressure Gauge, PSI - Rear Center 1/4 NPT Cover, MQ3-45 RO Delivery Pump Pump, MQ3-45 RO Delivery 110V 20 GPM Pump, MQ3-45 RO Delivery 220V 20 GPM Bulkhead Fitting,.5 for RO Fill Bulkhead Fitting,.75 for RO Fill Bulkhead Fitting, 1 for RO Fill Blending Kit HVE, w/flow Meter Blending Kit MVE w/flow Meter HVE/MVE - 5 Micron Sediment Filter MVE - Carbon Filter MVE/LVE - Membrane & Housing Kit HVE - Autoflush Kit LVE - RO Pump Kit RO Membrane - Low Energy - 4x Effective 05/01/

123 Fleck Fiberglass Section 9 Chloride Dealkalizers Fleck Fiberglass Chloride Dealkalizers (*) Note: Steel tanks & Plastic Valve Nest (*PVN) systems are offered on custom quote basis Section 9 - Fleck Fiberglass Chloride Dealkalizers Catalog NP Rev. F (05/17) Effective 05/01/17

124 Section 9 Table of Contents Fleck Fiberglass Chloride Dealkalizers Fiberglass Chloride Anion Delkalizer Specifications And Design Data What Is A Chloride Anion Dealkalizer? Simplex Dealkalizer FRP Recommended Resin And Gravel Loading Duplex Dealkalizers FRP s Duplex Recommended Resin And Gravel Loading Configurations VIP 1E Control Dealkalizer, FRP - Simplex VIP 1E Control Dealkalizer, FRP - Duplex Time Clock Control Dealkalizer, FRP - Simplex Section 9 - Fleck Fiberglass Chloride Dealkalizers Catalog NP Rev. F (05/17) Effective 05/01/17

125 Fleck Fiberglass Section 9 Chloride Dealkalizers What is a Chloride Anion Dealkalizer? Chloride Anion Dealkalizers are primarily used for the removal of alkalinity from boiler feed water. Removal of the alkalinity prevents insoluble carbonate precipitates from forming in the boiler tubes and stops corrosion, which may be due to carbonic acid formation. Dealkalization by ion exchange uses strong base anion resin, which is regenerated to the chloride form. A small amount of sodium hydroxide (caustic soda) may be utilized along with the sodium chloride (NaCl) to give slightly higher capacity and lower leakage. Chloride Anion Dealkalizers will remove 90-95% of the carbonate (CO 3 ) and bicarbonate (HCO 3 ) alkalinity as well as 99% of the sulfates (SO 4 ), nitrates (NO 3 ) and fluoride when regenerated with salt (NaCl) only. Dealkalizers will remove all of the CO 2 and give higher capacities when regenerated with both salt and sodium hydroxide (caustic soda). Chloride anion dealkalizers normally use an economy salt setting of 6 lbs of salt per cubic foot of resin. Caustic may be added at a dosage of 0.6 lbs per cubic foot of resin. The capacity of the dealkalizer is based on the chloride content of the raw water. System control can be provided using either VIP demand initiated controller or mechanical time clock, steel or fiberglass tanks. Chloride Anion Dealkalizers with valve nest construction are available for high flow applications. VIPE controller - This computer based demand initiated (metered) controller operates from 1 to 4 units, in either a parallel, alternating, electronic time clock or progressive configuration. The control will utilize alpha numeric, selfprompting programming for simple start up. EEPROM memory shall store the program data eliminating the need for a battery back-up or configuration input after power loss. It is prewired and includes twist lock electrical end connectors for installation ease. The controller will constantly monitor current operating conditions and is capable of displaying instantaneous flow rate throughout the system. Flow and operational data for each unit shall be independently displayable. A resettable totalizing flow counter will be included to measure the total water processed. The controller shall be self-diagnostic and capable of emitting an audible signal if it detests a system problem. The *UL listed controller operation will be 24V, 60 Hz, 1 ph and a suitable sized UL approved transformer(s) will be provided to convert 120V, 60Hz, 1ph power for system operation. A NEMA 4X enclosure will be used to house the controller. The VIP demand initiated controller offers a chemical feed pump relay. This chemical feed pump relay logic circuit provides a signal to activate an optional chemical feed pump to pre-feed sodium hydroxide (caustic soda) during regeneration, thereby increasing the capacity of tank s resin bed. Mechanical Time Clock control can be set with dials to regenerate daily at a pre-set time of day, or it can be set to skip a day or several days. Regeneration is automatic. The control operates the multiport valve and advances it through the various regeneration steps of backwash, brine draw, slow rinse, fast rinse and refill of the brine tank. Note: The dealkalizer s anion resin must be protected from hardness fouling. ECI recommends installing a water softener ahead of the Dealkalizer to prevent anion resin fouling. (*) Denotes controller features Effective 05/01/17 9-1

126 Section 9 Fleck Fiberglass Chloride Dealkalizers Fiberglass Chloride Anion Dealkalizer - Specifications and Design Data Simplex Units FRP s Grains (gpg) (2) Recommended Flow Rates Salt Setting Continuous Peak (3) 15lb/cf 10lb/cf 5lb/cf GPM Flow PSI Drop GPM Flow PSI Drop Mineral in. (4) in. Anion Resin Qty Cu.Ft. Max Drain Flow GPM Space (5) Reqmt LxDxH in. CA-91A x x18x62 CA-121A x x18x60 CA-141A x x18x71 CA-141B x65 1½ x18x71 CA-161B x65 1½ x24x72 CA-181B x65 1½ x24x72 CA-241B x72 1½ x24x82 4,000 to 20,000 per Cu. Ft.. CA-161C x x24x72 Anion resin CA-181C x x24x72 (See Note 1.) CA-241C x x24x87 CA-301C x x30x100 CA-361C x x24x100 CA-301E x x32x104 CA-361E x x42x104 CA-421E x x42x112 CA-481E x x52x112 NOTE: (1) is based on ratio of total exchangeable Anions (bi-carbonate, carbonate, sulfate and nitrate) to chlorides. The smaller the ratio the less capacity. The capacity can vary between 4,000 grains per cubic foot and 20,000 grains per cubic foot. only regeneration can reduce up to 70% capacity. (2) Weight and pressure drop data are estimates. (3) Dimension refers to nominal vessel size only. (4) When capacity is over 11,000 grains per cubic foot increase salt dosage to 8lbs per cubic foot and NaOH dosage to.8lbs per cubic foot to minimize alkalinity leakage. Quantity of Resin and Gravel required per above specifications 9x48 12x52 14x65 16x65 18x65 24x72 30x72 36x72 42x72 48x72 Resin Qty. 1 Cu. Ft. 2 Cu. Ft. 3 Cu. Ft. 4 Cu. Ft. 5 Cu. Ft. 10 Cu. Ft. 15 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. Gravel Qty. 12 lbs 25 lbs 50 lbs 100 lbs 100 lbs 150 lbs 250 lbs 300 lbs 400 lbs 600 lbs Effective 05/01/17 9-2

127 Fleck Fiberglass Section 9 Chloride Dealkalizers Fiberglass Chloride Anion Dealkalizer Specifications and Design Data (cont d) Duplex Parallel Units FRP s Grains (2) Salt Setting 15lb/cf 10lb/cf 5lb/cf Recommended Flow Rates Duplex Continuous GPM Flow PSI Drop Duplex Peak (3) GPM Flow PSI Drop Mineral in. (4) in. Anion Resin Qty Cu.Ft. Max Drain Flow GPM Space (5) Reqmt LxDxH in. CA-91A x x18x62 CA-121A x x18x60 CA-141A x x18x71 CA-141B x65 1½ x18x71 CA-161B x65 1½ x24x72 CA-181B x65 1½ x24x72 CA-241B 4,000 to 20,000 per Cu. Ft x72 1½ x24x82 CA-161C x x24x72 Anion resin CA-181C x x24x72 CA-241C (See Note 1.) x x24x87 CA-301C x x32x100 CA-361C x x42x100 CA-301E x x32x104 CA-361E x x42x104 CA-421E x x42x112 CA-481E x x52x112 NOTE: (1) is based on ratio of total exchangeable Anions (bi-carbonate, carbonate, sulfate and nitrate) to chlorides. The smaller the ratio the less capacity. The capacity can vary between 4,000 grains per cubic foot and 20,000 grains per cubic foot. only regeneration can reduce up to 70% capacity. (2) Weight and pressure drop data are estimates. (3) Dimension refers to nominal vessel size only. (4) When capacity is over 11,000 grains per cubic foot increase salt dosage to 8lbs per cubic foot and NaOH dosage to.8lbs per cubic foot to minimize alkalinity leakage. Quantity of Resin and Gravel required per above specifications (2)9x48 (2)12x52 (2)14x65 (2)16x65 (2)18x65 (2)24x72 (2)30x72 (2)36x72 (2)42x72 (2)48x72 Resin Qty. 2 Cu. Ft. 4 Cu. Ft. 6 Cu. Ft. 8 Cu. Ft. 10 Cu. Ft. 20 Cu. Ft. 30 Cu. Ft. 40 Cu. Ft. 60 Cu. Ft. 80 Cu. Ft. Gravel Qty. 24 lbs 50 lbs 100 lbs 200 lbs 200 lbs 300 lbs 500 lbs 600 lbs 800 lbs 1200 lbs Effective 05/01/17 9-3

128 Section 9 VIP 1E Control Simplex Demand Dealkalizer Fiberglass - Simplex Fleck Fiberglass Chloride Dealkalizers = Simplex tank operation. Hard water bypass during regeneration. = VIP 1E electronic time clock feature & UL listed. = Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. CA-241C-SNGL Fleck Valve Type Mineral (inches) Ship. Wt. 1 CA-91A-SNGL x x CA-121A-SNGL n/a 1x x CA-141A-SNGL n/a 14 x x CA-141B-SNGL n/a 14 x x CA-161B-SNGL n/a 16 x x CA-181B-SNGL n/a 18 x x CA-241B-SNGL n/a 24 x7 1, x CA-161C-SNGL n/a 16 x x CA-181C-SNGL n/a 18 x x CA-241C-SNGL x7 1, x50 1,000 CA-301C-SNGL x7 1, x50 1,490 CA-361C-SNGL n/a 36 x7 2, x48 1,880 3 CA-301E-SNGL n/a 30 x7 1, x50 1,515 3 CA-361E-SNGL n/a 36 x7 2, x48 1, CA-421E-SNGL n/a 4x7 2, x48 2,835 3 CA-481E-SNGL n/a 48 x7 4,500 5x60 3,670 Note: 1 and flow meters supplied with above products are plastic. n/a Denotes that systems are available. However, no part number has been assigned. Contact the factory for current pricing. Effective 05/01/17 9-4

129 Fleck Fiberglass Section 9 Chloride Dealkalizers VIP 1E Control Duplex Alternating Dealkalizer Fiberglass ALT 2 = Duplex alternating operation; No hard water bypass during regeneration. = VIP 1E electronic time clock feature & UL listed. Solid state single metered demand initiated regeneration including rate of flow, re-settable totalizing meter & self-diagnostic status monitoring. NEMA enclosed controller; Delayed or immediate regeneration. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH transformer included/ twist lock style electrical connections/ 24V control voltage. = Optional: VIP 2E triplex and/or quadraplex units available. CA-241C-ALT2 Fleck Valve Type Mineral (inches) Ship. Wt. 1 CA-91A-ALT x x CA-121A-ALT x x CA-141A-ALT x x CA-141B-ALT x x CA-161B-ALT x x CA-181B-ALT x x41 1, CA-241B-ALT x7 1, x50 2,270 CA-161C-ALT x x41 1,060 CA-181C-ALT x x41 1, CA-241C-ALT x7 1, x50 2,000 CA-301C-ALT x7 1, x50 2,980 CA-361C-ALT x7 2, x48 3,760 3 CA-301E-ALT x7 1, x50 3,030 3 CA-361E-ALT x7 2, x48 3, CA-421E-ALT x7 2, x48 5,760 3 CA-481E-ALT x7 4,500 5x60 7,340 Note: 1 and flow meters supplied with above products are plastic. n/a Denotes that systems are available. However, no part number has been assigned. Contact the factory for current pricing. Effective 05/01/17 9-5

130 Section 9 Time Clock Control Simplex Dealkalizer Fiberglass - Simplex Fleck Fiberglass Chloride Dealkalizers = Automatic mechanical time clock initiated regeneration. Hard water bypass during regeneration. = Lead-free brass multiport control valves with self-cleaning, hydraulically balanced positive acting piston. = Timed brine refills (eliminates constant line pressure on shut off float devices). = Standard safety-float valve shutoff on 400/700lb brine tanks. Optional on 1000lb and larger sizes. = High strength polyethylene tank liners for longer service life, FRP wrapped for strength and corrosion resistance. ANSI/NSF listed tanks. = 120V/60Hz/1pH operation. 7 Day Mech. Time Clock CA-241C-TC 1 Fleck Valve Type Mineral (inches) Ship. Wt. CA-91A-TC x x CA-121A-TC x x CA-141A-TC x x CA-91B-TC n/a 14 x x CA-161B-TC x x CA-181B-TC n/a 18 x x CA-241B-TC x7 1, x CA-161C-TC n/a 16 x x CA-181C-TC x x CA-241C-TC x7 1, x50 1,000 CA-301C-TC x7 1, x50 1,490 CA-361C-TC x7 2, x48 1,880 3 CA-301E-TC x7 1, x50 1,515 3 CA-361E-TC x7 2, x48 1, CA-421E-TC x7 2, x48 2,835 3 CA-481E-TC x7 4,500 5x60 3,670 n/a Denotes that systems are available. However, no part number has been assigned. Contact the factory for current pricing. Effective 05/01/17 9-6

131 Deionizer Systems Section 10 Deionizer Systems Two Bed, Mixed Bed, Regeneration Plants and Jumbo Exchange s Section 10 Deionizer Systems Catalog NP Rev. F (05/2017) Effective 05/01/17

132 Section 10 Deionizer Systems Table of Contents Dual-Bed Deionizers FRP s M Series Programmable Operation Lined Steel s PVN Series Programmable Operation FRP s PVN Series Programmable Operation Mixed-Bed Deionizers Lined Steel s PVN Series Programmable Operation Portable Exchange Deionizer Regeneration Plants Lined Steel s PVN Series Programmable Operation P.e.d.i. s Jumbo Lined Steel s With Skid Deionizer Components And Accessories System Components System Accessories Section 10 Deionizer Systems Catalog NP Rev. F (05/2017) Effective 05/01/17

133 Deionizer Systems Section 10 Dual-Bed Deionizers FRP s M Series Programmable Operation = Automatic or semi-automatic operation Automatic regeneration when water quality falls below pre-set limit or after manual initiation. = Constant monitoring of water quality. = Solid-state reliability for trouble-free service. = No untreated by-pass water. = Automatic shut down in the event of power failure. = Compact, non-corrosive components. = Fiberglass tanks for corrosion resistance. = Convenient, modular construction. = Easy, economical installation. = Optional recirculation pumps. = Parallel or Series Regeneration. = Programmable purge prior to regeneration. = 24 volt operation (120/60hz/1pH transformer included). DM12-Q-FRP Two Bed Deionizer Nominal (gpg) Service Flow Rate (gpm) Mineral Resin Quantity (cu. ft.) Min. Peak Cation Anion DM12-Q-FRP 40, x DM14-Q-FRP 60, x DM18-Q-FRP 100, x ,400 Ship Wt. Effective 05/01/

134 Section 10 Deionizer Systems Dual-Bed Deionizers Lined Steel s PVN Series Programmable Operation = Automatic or semi-automatic operation Automatic regeneration when water quality falls below pre-set limit or after manual initiation. = Constant monitoring of water quality. = Solid-state reliability for trouble-free service. = No untreated by-pass water. = Automatic shut down in the event of power failure. = Compact, non-corrosive components. = Vinyl Ester Lined Steel s with epoxy exterior for corrosion resistance. = Convenient, modular construction. = Easy, economical installation. = Optional recirculation pumps. = Parallel or series regeneration. = Programmable purge prior to regeneration. = 120 VAC power reduction transformer supplied inside control panel. = 24 volt operation (120/60hz/1pH transformer included). CQ Control DB48-PVN-Q Nominal Service Flow Mineral Resin Quantity Ship Rate (gpm) (cu. ft.) Wt. (gpg) Min. Peak Cation Anion DB18-PVN 100, x ,400 DB24-PVN 200, x ,800 DB30-PVN 300, x ,500 DB36-PVN 400, x ,100 DB42-PVN 600, x ,000 DB48-PVN 800, x ,000 Effective 05/01/

135 Deionizer Systems Section 10 Dual-Bed Deionizers FRP s PVN Series Programmable Operation = Automatic or semi-automatic operation Automatic regeneration when water quality falls below pre-set limit or after manual initiation. = Constant monitoring of water quality. = Solid-state reliability for trouble-free service. = No untreated by-pass water. = Automatic shut down in the event of power failure. = Compact, non-corrosive components. = Fiberglass tanks for corrosion resistance. = Convenient, modular construction. = Easy, economical installation. = Optional recirculation pumps. = Parallel or series regeneration. = Programmable purge prior to regeneration. = 120 VAC power reduction transformer supplied inside control panel. = 24 volt operation. CQ Control DB30-PVN-FRP-Q Nominal Service Flow Mineral Resin Quantity Ship Rate (gpm) (cu. ft.) Wt. (gpg) Cont. Peak Cation Anion DB18-PVN 100, x ,000 DB24-PVN 200, x ,100 DB30-PVN 300, x ,900 DB36-PVN 400, x ,800 DB42-PVN 600, x ,600 DB48-PVN 800, x ,500 Effective 05/01/

136 Section 10 Deionizer Systems Mixed-Bed Deionizers Lined Steel s PVN Series Programmable Operation = Automatic or semi-automatic operation Automatic regeneration when water quality falls below pre-set limit or after manual initiation. = Constant monitoring of water quality. = Solid-state reliability PLC Control for trouble-free service. = No untreated by-pass water. = Alternate regeneration water source piping - standard. = Automatic shut down in the event of power failure. = Two-stage air mix standard. = Compact, non-corrosive components. = Vinyl ester lined steel tanks with epoxy exterior for corrosion resistance. = Convenient, modular construction. = Easy, economical installation. = Optional recirculation pumps. = Simultaneous regeneration and chemical displacement. = kill option available for high purity systems. = Programmable purge prior to regeneration. = 24 volt operation (120/60hz/1pH transformer included). MB42-PVN Nominal (gpg) Service Flow Rate (gpm) Mineral Resin Quantity (cu. ft.) Cont. Peak Cation Anion MB18-PVN , x ,200 MB24-PVN , x ,700 MB30-PVN , x ,300 MB36-PVN , x ,300 Note: Cation resin is shipped in the hydrogen form. Anion resin is shipped in the chloride form. The quantities shown in the chart above are the quantities as shipped. Ship Wt. Effective 05/01/

137 Deionizer Systems Section 10 Portable Exchange Deionizer Regeneration Plants Lined Steel s PVN Series Programmable Operation = Separation vessel with Sch. 80 PVC piping designed for 100% expansion of anion resin. = Clear piping for resin transfer. = Regeneration skid with cation and anion regeneration vessels. = Direct PLC - Koyo DL-240 with OP620 interface (2-line x 20-character LCD). = Semi-automatic operation Automatic regeneration after initiation. = Monitor for water quality. = Temperature gauge with shut down switch standard system. = Automatically shuts down if excessive temperature is detected. = Separate regeneration water source for cation and anion. = Automatic shut-down in the event of power 60 Cu. Ft. Regeneration Plant failure. = Air mix vessel with Sch. 80 PVC piping. = Compact, non-corrosive components. = Vinyl ester lined steel tanks with epoxy exterior for corrosion resistance. = Convenient, modular construction. = Full 3 x 1 viewing windows in all vessels. = Simultaneous regeneration of cation and anion resin. RESIN SOLD SEPARATELY = regeneration standard (up-flow or down-flow). = Programmable automatic rinse to quality. = 120 VAC power required. 20 Cu. Ft. PEDI Plant 40 Cu. Ft. PEDI Plant 60 Cu. Ft. PEDI Plant Inlet Separation Vessel Cation Regen Vessel Anion Regen Vessel Mixing Vessel Resin Quantity (cu. ft.) Cation Anion x x60 24 x60 36 x x x60 36 x60 4x x96 4x60 48 x60 48 x Note: Contact factory for special requirements. s height is straight side shell height, not overall height. Effective 05/01/

138 Section 10 Deionizer Systems Small Portable Exchange Steel s (P.E.D.I) Lined Carbon Steel s Maximum Media Diameter = Vinyl ester interior lined steel tanks with epoxy cu. ft. corrosion resistance. = Inlet, outlet, fill ports all flanged connections cu. ft. exterior for = Hub-radial PVC under-drain system cu. ft. = Steel skid cu.ft cu. ft. RESIN SOLD SEPARATELY Effective 05/01/

139 Deionizer Systems Section 10 Deionizer Components and Accessories System Components Controls Type # Description Voltage CQ CQ DM DB Quality initiated solid-state control panel with resistivity meter for measuring water quality. Use with 5-cycle Valve M-Series Deionizer. Quality initiated solid-state control panel with resistivity meter for measuring water quality. NEMA-4X Enclosure Use with DB Series (Valve Nest) Deionizer 24V V Effective 05/01/

140 Section 10 Deionizer Systems Deionizer Components and Accessories System Accessories Recirculation Pumps Assembly with Flow Meter Type Description Pump Volts Relay Voltage 24 VAC 7 GPM For 3/4 and 1 Piping 120V GPM For Piping 120V GPM For 3 Piping 120V Effective 05/01/

141

142 ECI 1890 Woodland Drive, Woodbury, MN Phone: Fax: Website:

Fleck Top Mount Section 1 Fiberglass Softeners

Fleck Top Mount Section 1 Fiberglass Softeners Fleck Top Mount Section 1 Fleck Top Mount *Shown with factory SKID & Interconnecting Plumbing *Shown with factory SKID & Interconnecting Plumbing Section 01 Fleck Top Mount Catalog 999701-NP Rev. F (05/17)

More information

SECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing

SECTION 1. Fleck Fiberglass Softeners. *Shown with factory SKID & Interconnecting Plumbing SECTION 1 *Shown with factory SKID & Interconnecting Plumbing Fleck Fiberglass Softeners Section 01 Fleck Fiberglass softeners Catalog 999502 Effective 01/01/13 Section 01 Fleck Fiberglass softeners Catalog

More information

Fleck Epoxy Lined Section 2 Steel Softeners

Fleck Epoxy Lined Section 2 Steel Softeners Epoxy Lined Section 2 Epoxy Lined *Shown with factory SKID & Plumbing Section 02 Epoxy Lined Catalog 999701-NP Rev. F (05/17) Effective 05/01/17 Section 2 Table of Contents Epoxy Lined Steel Softener Specifications

More information

Fleck Fiberglass Section 9 Chloride Dealkalizers

Fleck Fiberglass Section 9 Chloride Dealkalizers Fleck Fiberglass Section 9 Fleck Fiberglass (*) Note: Steel tanks & Plastic Valve Nest (*PVN) systems are offered on custom quote basis Section 9 - Fleck Fiberglass Catalog 999701-NP Rev. F (05/17) Effective

More information

Plastic Valve Nest Epoxy Lined Section 7 Steel Filters - 18 thru 48

Plastic Valve Nest Epoxy Lined Section 7 Steel Filters - 18 thru 48 Plastic Valve Nest Epoxy Lined Steel Filters 18 thru 48 Section 07 PVC Valve Nest Steel Filters Catalog 999701-NP Rev. F (05/17) Effective 05/01/17 Section 7 Table of Contents Plastic Valve Nest Epoxy

More information

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS 5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS 1.0 SCOPE 1.1

More information

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS PRICE SCHEDULE #101016 EFFECTIVE: OCTOBER 1, 2016 MADE IN BRAZIL, UNLESS NOTED 117 Gulick Street, Blossburg, PA 16912 www.wardmfg.com (800) 248-1027

More information

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS 2227 South Street P.O. Box 044170 Racine, Wisconsin 53404-7003 Phone: 262-681-1300 Fax: 262-681-1318 www.marlo-inc.com DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS 1.0 SCOPE 1.1 Provide

More information

STC 2L Series Solenoid Valves

STC 2L Series Solenoid Valves STC 2L170-500 Series Solenoid Valves 2L170-500 Series Solenoid Valve Specifications Valve Model 2L170-3/8 2L170-1/2 2L170-3/4 2L200-1 2L300-1 1/2 2L500-2 Valve Type Action 2 Way, Normally Closed (NC) Pilot

More information

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS 5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS 1.0 SCOPE 1.1 Provide

More information

Float Level Control Kits

Float Level Control Kits Float Level Control Kits ASOFK, SPFK and FLC SpectraPure Inc. assumes no responsibility for water damage due to leaks. It is the user s responsibility to determine that the system is leak-free. INSTALLATION

More information

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure S T C TM To Order, Please Specify: 1) Model No., 2) Voltage 2 Way, NC Pilot Piston Stainless Steel Part No. Voltage

More information

STC 2W Series Solenoid Valves

STC 2W Series Solenoid Valves STC 2W160-500 Series Solenoid Valves 2W160-500 Series Solenoid Valve Specifications Valve Model 2W160-3/8 2W160-1/2 2W200-3/4 2W250-1 2W350-1 1/4 2W400-1 1/2 2W500-2 Valve Type Action 2 Way, Normally Closed

More information

3V SERIES SOLENOID VALVE

3V SERIES SOLENOID VALVE 3V110-410 SERIES SOLENOID VALVE Valve Model 3V110-1/8 3V210-1/4 3V310-3/8 3V410-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Air Pilot, Spool Design, Response Time

More information

4V130P-430P SERIES AIR PILOT VALVE

4V130P-430P SERIES AIR PILOT VALVE 4V130P-430P SERIES AIR PILOT VALVE Valve Model 4V130P-1/8 4V230P-1/4 4V330P-3/8 4V430P-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Double Solenoid, Spool Design, 3 Position, Pressure

More information

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves STC 2DS500-2000 Series Anti-Hammering Slow Closing Pilot Solenoid Valves 2DS500-2000 Series Solenoid Valve Specifications Valve Model 2DS400F 2DS500F 2DS650F 2DS800F 2DS1000F 2DS1250F 2DS1500F 2DS2000F

More information

Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS

Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS Clean and soft water for business needs. Commercial softening equipment. COMMERCIAL WATER SOFTENERS Application of Commercial Water Softening Equipment Water hardness is responsible for many maintenance

More information

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS PRICE SCHEDULE #100217 EFFECTIVE: FEBRUARY 6, 2017 REV. 1 MADE IN BRAZIL, UNLESS NOTED 117 Gulick Street, Blossburg, PA 16912 (800) 248-1027 Sheet #100217,

More information

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way Ordering Part No. = (e.g., E 1/2-3-S) Indicator / Control E 1/2 - - - 3-S Model Name Electric Actuated Valves E Port Size

More information

STC 2P025 Series Solenoid Valve

STC 2P025 Series Solenoid Valve STC 2P025 Series Solenoid Valve 2P025 Series Solenoid Valve Specifications Valve Model Valve Type Action Cv (Orifice) Operating Pressure Operating Temperature 2P025 2 Way, Normally Closed (NC) Direct Acting

More information

TNT SERIES WATER CONDITIONERS

TNT SERIES WATER CONDITIONERS TNT SERIES WATER CONDITIONERS For Commercial & Industrial Applications Apartment Buildings Boiler Water Treatment Car Washes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home

More information

INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES

INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES 150,000 TO 900,000 GRAIN CAPACITY (Single, Twin Alternating, Triple or Quadruple Demand Systems) 1 P age Industrial Performance and Proven Reliability

More information

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter

More information

2V1-3V1 SERIES SOLENOID VALVE

2V1-3V1 SERIES SOLENOID VALVE 2V1-3V1 SERIES SOLENOID VALVE Valve Model 2V1 3V1 Port & Mounting Body Ported, Stacking Action & Motion Solenoid, Direct Acting, 2 Way Response Time

More information

STEEL PIPE NIPPLES - WELDED Price Sheet PNW-7.18 Effective: July 16, 2018 Cancels Price Sheet PNW-3.18 of March 5, 2018

STEEL PIPE NIPPLES - WELDED Price Sheet PNW-7.18 Effective: July 16, 2018 Cancels Price Sheet PNW-3.18 of March 5, 2018 STEEL PIPE NIPPLES - WELDED Price Sheet PNW-7.18 Effective: July 16, 2018 Cancels Price Sheet PNW-3.18 of March 5, 2018 FOR THE MOST CURRENT PRODUCT/PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE VISIT

More information

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide 7.3L POWERSTROKE BANJO BOLT KIT Fits 94-03 7.3L Powerstroke Diesel Installation Guide INSPECT CONTENTS OF THIS KIT THOROUGHLY BEFORE STARTING THE INSTALLATION PROCESS! IF YOU FIND A PROBLEM WITH YOUR PACKAGE:

More information

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR) TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for

More information

BI-PIPE INSTALLATION MANUAL. AUDI PERFORMANCE & RACING 1027-B Opelika Road Auburn Alabama 36830

BI-PIPE INSTALLATION MANUAL. AUDI PERFORMANCE & RACING 1027-B Opelika Road Auburn Alabama 36830 BI-PIPE INSTALLATION MANUAL i. Disclaimer TABLE OF CONTENTS ii. iii. iv. Tools Needed Parts In the Kit Installation Procedure TABLE OF CONTENTS , LLC does not endorse modification of vehicles for use in

More information

6A-1773 Q ISO-2944

6A-1773 Q ISO-2944 6A-1773 Q1-2801 ISO-2944 Lowery Well Heads, Inc. Quality is #1 We are happy to announce that as of 9-11-15 we are now API Q1 and ISO 9001 certified. Lowery Well Heads, Inc. is committed to its customer

More information

Commercial Softeners

Commercial Softeners Commercial Softeners Product Index Page General System Specifications 35 Fleck Commercial Valve Configurations 36 Fleck 9500 1-1/" Systems 37 Fleck 850 1-1/" Systems 38 Fleck 3150 " Systems 39 Fleck 900

More information

Specialty Products. Strainers. Check Valves. Butterfly Valves

Specialty Products. Strainers. Check Valves. Butterfly Valves Specialty Products Strainers Check Valves Butterfly Valves Effective Date: April 1, 2013 Trademarks: Viton is a trademark of DuPont Performance Elastomers, L.L.C. Teflon is a trademark of E. I du Pont

More information

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø CAT231.1 STANDARD TASK MASTER III - 1 ½ VALVE 316 SS - SIDE MOUNT SERVICE FLOW BYPASS DIAPHRAGM VALVES. ERCt ELECTRONIC TIMER 100 PSI EPOXY LINED AND COATED CARBON STEEL MINERAL TANKS ACCUMATIC BRINE SYSTEM.

More information

SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement

SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement This Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement (the Agreement ) is entered

More information

GWC Valve International

GWC Valve International GWC Valve International PROVEN TECHNOLOGY FOR INDIVIDUAL VALVE SOLUTIONS WORLDWIDE API 6D SWING CHECK VALVES Pressure Class: ASME 150-2500 Size Range: 2-36 CATALOG NUMBER SC-1001 G W C V A L V E I N T

More information

Price List. Specialty Products / Strainers / Check Valves / Butterfly Valves. Effective July 2, MuellerSteam.com 2018 MUELLER PRICE LIST

Price List. Specialty Products / Strainers / Check Valves / Butterfly Valves. Effective July 2, MuellerSteam.com 2018 MUELLER PRICE LIST 2018 MUELLER PRICE LIST Price List Specialty Products / Strainers / Check Valves / Butterfly Valves Effective July 2, 2018 All prices supersede previous issues, are temporary and subject to change without

More information

PVI 60KW, PVI 82KW, PVI 95KW

PVI 60KW, PVI 82KW, PVI 95KW PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy

More information

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities New Ulm Public Utilities Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities INDEX Document Review and History... 2 Definitions... 3 Overview... 3 Application

More information

CREATIVE BUS SALES, INC. REPRESENTING MOBILITY VENTURES, LLC

CREATIVE BUS SALES, INC. REPRESENTING MOBILITY VENTURES, LLC CREATIVE BUS SALES, INC. REPRESENTING MOBILITY VENTURES, LLC ORDER PACKET Contract #TRIPS-12-SNV-CBS Special Needs Type Vehicles TRIPS-12-SNV-CBS - 1 - October 2012 CONTRACT # TRIPS-12-SNV-CBS ORDER PACKET

More information

BOXES CSA 1. D BOXES CSA 1 DIMENSIONS

BOXES CSA 1. D BOXES CSA 1 DIMENSIONS STEEL ALUMINUM indoor Indoor D BOXES CSA 1. D BOXES CSA 1 DIMENSIONS Ship Wt. List DIMENSIONS Ship Wt. List CAT. NO. H W D (LBS.) Price CAT. NO. H W D (LBS.) Price D-S-060603 6 6 3 2 11.80 D-A-060603 6

More information

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES 150,000 TO 1,100,000 GRAINS CAPACITY (Single, Twin, Triple or Quadruple Demand Systems Available) 1 P age Industrial Performance and Proven Reliability

More information

q u i e t price list march 2018

q u i e t price list march 2018 q u i e t price list march 201 quiet terms and conditions Sales and Service Policy uidelines detailing the operating policies and procedures of Bernhardt Design are provided in the Sales and Service Policy

More information

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8 2P050-3/8F

More information

RSPO PalmTrace - Book and Claim Terms and Conditions

RSPO PalmTrace - Book and Claim Terms and Conditions 1. Introduction 1.1 The Roundtable on Sustainable Palm Oil ( RSPO ), a non-profit association registered in Switzerland under Swiss law, supports the following supply chain models for the uptake of certified

More information

Creative Bus Dba Getaway Bus REPRESENTING New England Wheels

Creative Bus Dba Getaway Bus REPRESENTING New England Wheels Creative Bus Dba Getaway Bus REPRESENTING New England Wheels ORDER PACKET Contract #TRIPS-15-MB-GB MiniBus with ADA Option CONTRACT # TRIPS-15-MB-GB ORDER PACKET FOR MiniBus with ADA Option Creative Bus

More information

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER CAT231.1 STANDARD FEATURES TASK MASTER III - 1 ½ / 2 - FIVE CYCLE 316 STAINLESS STEEL VALVE - SIDE MOUNT SUPER FLOW KIT S ON 2, 3 & 4 SYSTEMS (SERVICE FLOW BYPASS DIAPHRAGM VALVES) ERCt ELECTRONIC TIMER

More information

2015 & 2018 Fender Brace Installation Instructions

2015 & 2018 Fender Brace Installation Instructions 2015 & 2018 Fender Brace Installation Instructions Thank you for your purchase of this Hotchkis Performance product. Your Fender Brace set was designed with the performance and durability you ve come to

More information

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev Patent No. 6520259 Installation Manual P/N 95232 Rev 6-16-11 Table of Contents ing Extraction Inlets track changing water levels to maintain optimum performance 1.Component Identification Page 1 2. How

More information

Rig Master Power by Mobile Thermo Systems Inc.

Rig Master Power by Mobile Thermo Systems Inc. RigMaster Power Dealer Warranty Policy The Limited Warranty This limited warranty applies to the RigMaster Auxiliary Power Unit (RigMaster APU) which consists of the following components: 1. The generator

More information

Universal Bevel Drives Service Manual

Universal Bevel Drives Service Manual Engineering Service Bulletin #SB241202 Universal Bevel Drives Service Manual Cautions Following are some general cautions. All personnel shall use safe and sound practices and take all necessary precautionary

More information

Anti-roll bar set Chrysler Magnum, Charger, 300C, SRT Dodge Challenger

Anti-roll bar set Chrysler Magnum, Charger, 300C, SRT Dodge Challenger Anti-roll bar set 22101 Chrysler Magnum, Charger, 300C, SRT-8 22107 Dodge Challenger Thank you for your purchase from our new line of Chrysler parts. Please call us at (877) 4NO-ROLL if you have any questions

More information

AURORA WIRE SHELVING PRICE LIST

AURORA WIRE SHELVING PRICE LIST AURORA WIRE SHELVING PRICE LIST Effective January 6, 2014 AURORA STORAGE PRODUCTS, INC. TABLE OF CONTENTS Certificate of Warranty............................................................... Page 2

More information

PRICE SHEET TABLE OF CONTENTS AWWA VALVES & HYDRANTS. (PL-0418-AWWA Replaces PL-1014-VLV)

PRICE SHEET TABLE OF CONTENTS AWWA VALVES & HYDRANTS. (PL-0418-AWWA Replaces PL-1014-VLV) Page(s) 1 2 3 3 4 4 5 5 6 PRICE SHEET TABLE OF CONTENTS VALVES & HYDRANTS ( Replaces PL-1014-VLV) Product Line C515 NRS Gate Valves Series 1010 UL/FM C515 NRS Gate Valves Series 2010 C508 Swing Check Valves

More information

Dispenser Pan Sensors & Containment Sump Sensors

Dispenser Pan Sensors & Containment Sump Sensors Manual No: 576013-306 Revision: G Dispenser Pan Sensors & Containment Sump Sensors Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not

More information

DEALER REGISTRATION PACKAGE

DEALER REGISTRATION PACKAGE DEALER REGISTRATION PACKAGE. Please return this completed paperwork by mail, fax or email: Sunflower Auto Auction P.O. Box 19087 Topeka, Kansas 66619 PHONE 785-862-2900 FAX 785-862-2902 Email:info@SunflowerautoAuction.com

More information

LINTECH.

LINTECH. Welcome to Our local technical support group consists of Automation Specialists located throughout the World. These Automation Specialists are experienced in the use of electronic and mechanical motion

More information

Utility Controller Hand Air Operated

Utility Controller Hand Air Operated Utility Controller Hand Air Operated P-1395 819-0288 Installation Instructions Introduction The Warner Electric air/manual Utility Controller combines manual and automatic (air) actuation for the operation

More information

2009 MFJ ENTERPRISES, INC.

2009 MFJ ENTERPRISES, INC. Model MFJ-4416BRC INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment MFJ ENTERPRISES, INC. 300 Industrial Park Road Starkville, MS 39759 USA Tel: 662-323-5869 Fax: 662-323-6551

More information

Updated: October 2012

Updated: October 2012 T: (630) 794-5100 EMERGENCY POWER FUEL SYSTEMS Earthsafe Systems, Inc. 7320 S. Madison Willowbrook, IL 60527 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com Updated: October 2012 The information

More information

PVC Gasketed Fittings for PVC IPS Pressure Pipe ENGINEERED FOR DURABILITY

PVC Gasketed Fittings for PVC IPS Pressure Pipe ENGINEERED FOR DURABILITY For the most up-to-date version of this price list, EFFECTIVE MARCH 4, 2019 ENGINEERED FOR DURABILITY HARRINGTON CORPORATION P.O. BOX 10335 LYNCHBURG, VIRGINIA 24506-0335 For the most up-to-date version

More information

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

California Independent System Operator Corporation Fifth Replacement Electronic Tariff Table of Contents 41. Procurement Of RMR Generation... 2 41.1 Procurement Of Reliability Must-Run Generation By The CAISO... 2 41.2 Designation Of Generating Unit As Reliability Must-Run Unit... 2 41.3

More information

P/N# Performance Lowering Springs Installation Instructions

P/N# Performance Lowering Springs Installation Instructions P/N# 19391 Performance Lowering Springs Installation Instructions Thank you for your purchase of this Hotchkis Performance product. Your Lowering Spring set was designed with the performance and durability

More information

INSTRUCTIONS. Triangulated 4-Link Coil Over Rear Suspension System (RS-2450) For FORD Muscle Cars: FAIRLANE

INSTRUCTIONS. Triangulated 4-Link Coil Over Rear Suspension System (RS-2450) For FORD Muscle Cars: FAIRLANE FORD 1962-65 FAIRLANE 4-LINK TRIANGULATED SYSTEM INSTRUCTIONS Triangulated 4-Link Coil Over Rear Suspension System (RS-2450) For FORD Muscle Cars: 1962-1965 FAIRLANE Revised: 10-1-2011 1962-1965 Fairlane

More information

Price List. Catalog Eleven. Rigging. Effective February 16, Specialties Inc. manufacturer of stage equipment

Price List. Catalog Eleven. Rigging. Effective February 16, Specialties Inc. manufacturer of stage equipment Price List Catalog Eleven Rigging Effective February 16, 2015 & manufacturer of stage equipment (626) 575-0776 14850 Don Julian Road, Suite B (800) 221-9995 City of Industry CA 91746 www.hhspecialties.com

More information

22421 SPORT SWAY BAR SET TOYOTA COROLLA

22421 SPORT SWAY BAR SET TOYOTA COROLLA 22421 SPORT SWAY BAR SET 98-01 TOYOTA COROLLA Thank you for your purchase from our line of Corolla parts. Please call us at (877) 4NO-ROLL if you have any questions regarding the service or installation

More information

Owner s Manual Pelican Whole House Iron and Manganese Filtration System

Owner s Manual Pelican Whole House Iron and Manganese Filtration System Owner s Manual Pelican Whole House Iron and Manganese Page 2 Copyright 2011 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of. makes no warranty of any

More information

MOVE ON TO THE REAR BAR INSTALLATION

MOVE ON TO THE REAR BAR INSTALLATION 22410 STREET SWAY BAR SET 2001-UP LEXUS IS300 Thank you for your purchase from our line of Lexus parts. Please call us at (877) 4NO-ROLL if you have any questions regarding the service or installation

More information

GENERAL INFORMATION 2

GENERAL INFORMATION 2 0 1 GENERAL INFORMATION 2 3 TABLE OF CONTENTS FENDER CLASSIFICATION 3 FENDER MATERIALS.. 4-5 SINGLE FENDERS 8-15 DOUBLE RADIUS 8-9 90 BACK.. 10-11 SLANT BACK... 12-13 JEEP AND DROP LEG 14-15 TANDEM FENDERS..

More information

Anti-Roll Bar Set # 2279, Cadillac CTS V6 & CTS-V

Anti-Roll Bar Set # 2279, Cadillac CTS V6 & CTS-V Anti-Roll Bar Set # 2279, 2280 2003+ Cadillac CTS V6 & CTS-V Thank you for your purchase from our new line of CTS parts. Please call us at (877) 4NO-ROLL if you have any questions regarding the service

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com ISO 9001:2000 Certified

More information

14366, Adjustable Strut Rods Chrysler A-Body Chrysler B-Body Chrysler E-Body

14366, Adjustable Strut Rods Chrysler A-Body Chrysler B-Body Chrysler E-Body 14366, 14385 Adjustable Strut Rods 67-76 Chrysler A-Body 1966-1970 Chrysler B-Body 1970-1974 Chrysler E-Body Thank you for your purchase from our new line of B & E-Body parts. Please call us at (877) 4NO

More information

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC FREQUENTLY ASKED QUESTION SERIES BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC Ihave been getting a bunch more comments and questions from customers

More information

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23 P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23 Canceling P.S.C. Mo. No. 5 Sec. 4 Original Sheet No. 23 PURPOSE: The purpose of this Rider SR is to implement the solar rebate established through 393.1030

More information

SUPERPLUS WATER FILTRATION SYSTEM

SUPERPLUS WATER FILTRATION SYSTEM SUPERPLUS WATER FILTRATION SYSTEM For Model #: SP20-1 INSTRUCTIONS/ASSEMBLY USE AND CARE MANUAL (Important: Read this manual thoroughly before install) TABLE OF CONTENTS 2 3 4 6 8 9 10 11 12 General Notes

More information

S T C. STC Air Actuated Valves. Fine Quality. Precision Engineered Advanced Design. Excellent Prices. connects fluid power to industrial automation TM

S T C. STC Air Actuated Valves. Fine Quality. Precision Engineered Advanced Design. Excellent Prices. connects fluid power to industrial automation TM Precision Engineered Advanced Design Catalog No.: PUB09KS STC Air Actuated Valves Fine Quality Excellent Prices connects fluid power to industrial automation Website: StcValve.com STC PNEUMATIC ACTUATED

More information

Manual No: Revision: F. Mag Probe Assembly Manual

Manual No: Revision: F. Mag Probe Assembly Manual Manual No: 576013-730 Revision: F Mag Probe Assembly Manual Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability

More information

CN is offering our Fleet Integration Program for grain shippers who are using privately owned, covered hopper cars for

CN is offering our Fleet Integration Program for grain shippers who are using privately owned, covered hopper cars for US Covered Hopper Fleet Integration Program CN is offering our Fleet Integration Program for grain shippers who are using privately owned, covered hopper cars for their shipments. The objectives of this

More information

Hydraulic Fittings. Design, Manufacture, Distribution

Hydraulic Fittings. Design, Manufacture, Distribution Hydraulic Fittings Design, Manufacture, Distribution Hydraulic Fittings are exclusively distributed by Beaumanor Engineering Ltd of Leicester and manufactured by Balu Auto Components of Chennai India,

More information

78-88 G Body Rear Trailing Arm Kit

78-88 G Body Rear Trailing Arm Kit May 14, 2014 78-88 G Body Rear Trailing Arm Kit Parts in this kit may vary slightly from photo. The following instructions are intended for professional installers and are guidelines only. Speedtech Performance

More information

PETROLEUM TRADERS CORPORATION RIGGINS, INC.

PETROLEUM TRADERS CORPORATION RIGGINS, INC. BID RESULTS CK09MERCER2015-10 DIESEL FUEL AND WINTER MIX FOR THE COUNTY OF MERCER AND THE MERCER COUNTY COOPERATIVE MEMBERS BID OPENING DATE: JUNE 30, 2015 AWARD FOR A PERIOD OF TWO (2) YEARS; BASED UPON

More information

Dealer Registration. Please provide the following:

Dealer Registration. Please provide the following: Dealer Registration Please provide the following: A copy of your Dealer s License A copy of your Sales Tax Certificate A copy of the Driver s License for all representatives A copy of your Master Tag Receipt

More information

Sport Sway Bar Kit Chevy Camaro

Sport Sway Bar Kit Chevy Camaro Sport Sway Bar Kit 22109 2010 Chevy Camaro Thank you for your purchase from our new line of Chevy parts. Please call us at 877-4NO - ROLL if you have any questions regarding the service or installation

More information

Parts Manual Vermeer/ McLaughlin Mud System 230P

Parts Manual Vermeer/ McLaughlin Mud System 230P 2006 Perimeter Road. Greenville, SC 29605 Toll Free: 800/435-9340 - Phone: 864/277-5870 Fax: 864/235-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual Vermeer/

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL JANUARY

More information

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS. 25.211. Interconnection of On-Site Distributed Generation (DG). (a) (b) (c) Application. Unless the context indicates otherwise, this section and 25.212 of this title (relating to Technical Requirements

More information

PRESSURE GAGES AND TEST TAPS

PRESSURE GAGES AND TEST TAPS CAT 500.1 FRF series filters. Polyglass 100 psi vessels with top mount Task Master II 1 ½ valve and single point PVC internals. FMF series filters. Carbon steel epoxy lined and coated vessels with side

More information

65 Series. Valve Operation Manual

65 Series. Valve Operation Manual 65 Series Valve Operation Manual Note: 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified lubricant

More information

OMNI GEAR TRACTOR POWERED IMPLEMENT GEARDRIVES

OMNI GEAR TRACTOR POWERED IMPLEMENT GEARDRIVES TRACTOR POWERED IMPLEMENT GEARDRIVES PHD-15 Series 1750 lb.-in. 198 Nm. Ratios: 3:1 Tapered, Ball, Needle Oil Cap: 25 oz. (0.7 L) 26 lbs. (11.8 kg) Power: 15 hp 11 kw Post Hole Digger Drives PHD-25 Series

More information

Sport Sway Bar Kit (22431 ) Subaru Forester INSTALLATION OF HOTCHKIS FRONT SWAY BAR

Sport Sway Bar Kit (22431 ) Subaru Forester INSTALLATION OF HOTCHKIS FRONT SWAY BAR Sport Sway Bar Kit (22431 ) Subaru Forester Thank you for your purchase from our new line of Forester parts. Please call us at (877) 4NO - ROLL if you have any questions regarding the service or installation

More information

London Hydro Connection Checklist

London Hydro Connection Checklist London Hydro Connection Checklist Applicants should be aware not to incur expenses prior to London Hydro approving the connection of the facility to the grid. Payment of Connection Fee: $1000 plus HST

More information

A DECADE OF INNOVATION IN BRUSHLESS FUEL PUMP TECHNOLOGY

A DECADE OF INNOVATION IN BRUSHLESS FUEL PUMP TECHNOLOGY 2019 DIESEL CATALOG A DECADE OF INNOVATION IN BRUSHLESS FUEL PUMP TECHNOLOGY A Decade of Innovation in Brushless Fuel Pump Technology WWW. FUELAB.COM VELOCITY SERIES DIESEL LIFT PUMPS FUELAB has been bringing

More information

Anti-roll bar set (pn 2278) Pontiac GTO

Anti-roll bar set (pn 2278) Pontiac GTO Anti-roll bar set (pn 2278) Pontiac GTO Thank you for your purchase from our new line of GTO parts. Please call us at (877) 4NO-ROLL if you have any questions regarding the service or installation of your

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121114C OWNERS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 1301 / 1302 / 1305 / 1306 THANK YOU FOR CHOOSING HOTCHKIS PERFORMANCE PRODUCTS Removal of Stock Lower Trailing Arms 1) Place car on level surface. 2) Support rear of the car on

More information

Consumer Guidelines for Electric Power Generator Installation and Interconnection

Consumer Guidelines for Electric Power Generator Installation and Interconnection Consumer Guidelines for Electric Power Generator Installation and Interconnection Habersham EMC seeks to provide its members and patrons with the best electric service possible, and at the lowest cost

More information

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility Processed Date Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility Customer s Printed Name Installation Street Address Account Number Please note: Columbia Water & Light

More information

Pipe Hangers, Strut & Accessories

Pipe Hangers, Strut & Accessories I N D U S T R I E S I N C. Base Price List September 22, 2008 Pipe Hangers, Strut & Accessories Phone 800.243.4844 860.647.1431 Fax 860.647.1160 180 Olcott Street Manchester, CT 06040 w w w. e m p i r

More information

Umatilla Electric Cooperative Net Metering Rules

Umatilla Electric Cooperative Net Metering Rules Umatilla Electric Cooperative Net Metering Rules Version: July 2017 Umatilla Electric Cooperative NET METERING RULES Rule 0005 Scope and Applicability of Net Metering Facility Rules (1) Rule 0010 through

More information

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD 2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD Thank you for your purchase of this Hotchkis Performance product. Please call us at (800) 4NO-ROLL if you have any questions regarding this product.

More information

Municipality Generator Interconnection Application Single Meter Application Part I

Municipality Generator Interconnection Application Single Meter Application Part I Municipality Generator Interconnection Application Single Meter Application Part I New Application Revised Application A single customer interconnecting to a single meter at a single premise makes a new

More information