en Internal vibrators IRSEN-FU Operator's manual

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "en Internal vibrators IRSEN-FU Operator's manual"

Transcription

1 en Internal vibrators IRSEN-FU Operator's manual

2

3 1. Foreword Foreword For your own safety and protection from bodily injuries, carefully read, understand and follow the safety information in this manual. Please operate and maintain your Wacker machine in accordance with the instructions in this operator's manual. Your Wacker machine will reward you with troublefree operation and a high degree of availability. Defective components must be replaced immediately. All rights, especially the right for copying and distribution, are reserved Copyright 2007 by Wacker Construction Equipment AG No part of this publication may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express permission in writing from Wacker Construction Equipment AG. Any type of reproduction, distribution or saving on data carriers of any type or method not authorized by Wacker represents an infringement of valid copyrights and will be prosecuted. We expressly reserve the right to make technical modifications - even without special notice - which aim at further improving our machines or their safety standards. 3

4 Table of contents 1. Foreword 3 2. Safety information General instructions Operation Safety checks Maintenance Transport Maintenance checks Technical data 9 4. Description Application Functional description Operation Starting up Connection using separate extension cable Switching off the machine Description/maintenance Protection against overheating Maintenance schedule Disassembly and assembly Maintenance Repair instructions Repair instructions, faults Wear dimensions Disposal Environmentally friendly recycling...23 EC Declaration of Conformity 25 DIN EN ISO 9001 Certificate 27 4

5 Internal vibrators 2. Safety information for internal vibrators with electric motor drive 2.1 General instructions Safety information Internal vibrators may only be worked on independently by persons who * are at least 18 years of age, * are physically and mentally fit for this job, * have been instructed in operating internal vibrators and have proved their ability for the job to the employer and * may be expected to carry out the job they are charged with carefully. They must have been assigned to work on the internal vibrators by the company Internal vibrators are to be applied only for compacting work. Both the manufacturer's operator's manual and this safety information must be observed. The machine must be immersed in the mass to be compressed The persons charged with the operation of internal vibrators must be made familiar with the necessary safety measures relating to the machine. In case of extraordinary uses, the employer shall give the necessary additional instructions Observe the accident prevention regulations set forth by the professional association for electrical equipment and material and use them as a basis during all work performed with this machine This machine generates noise that exceeds the country-specific permissible noise levels (individual rating level). It may therefore be necessary to wear ear protection. 2.2 Operation You must ensure that the internal vibrators with electric motor drive are only attached to the voltage and frequency indicated on the nameplate. The nameplate is located on the inside of the switch box cover. Choose correct cross section for extension cord. SV00042en.fm 5

6 Safety information Internal vibrators These internal vibrators may only be connected to electric power supplies with a fault current protective switch. Used inverters must correspond to VDE For voltages greater than 42 volts, they must be provided with protective breakers (-). When used on construction sites, inverters must be operated via a separate supply point, which is provided with a fault current protective switch Vibrators, which are operated with protective low voltage 42 volts, correspond to class rating III. Vibrators with a higher operating voltage correspond to class rating I (grounded conductor) Prior to starting the internal vibrator, make sure that the components are screwed on securely Activated internal vibrators should not come into contact with any solid objects over a long period of time, long running times in the air must be avoided When taking a break or when leaving the internal vibrator, the operator must switch off the machine and park it securely in such a way to ensure that it cannot tip over or fall down The power cable of the internal vibrator must not be used to pull out the plug from the plug receptacle. Do not insert or pull out the power plug as a means of turning the internal vibrator on or off Protect electric cable from heat, oil, and sharp edges Appropriate protective gloves must always be worn when handling internal vibrators. Do not touch the hot vibration body The protective hose must be used to guide the machine during operation. Using the vibration body to guide the internal vibrator can cause vascular diseases The transmission of vibration oscillations to the material to be compacted can damage or destroy the casing. Casings must be secured according to regulations before using the machine Electrical equipment and material may only be used if they comply with operational and local safety requirements. They must be in proper condition and this condition is to be maintained Do not operate internal vibrators in areas where explosions may occur. SV00042en.fm 6

7 Internal vibrators 2.3 Safety checks Safety information Before starting operation, the operator has to check that all control and safety devices are functioning properly Prior to connecting the machine, check the electric cable and socket for damage on a regular basis Also check the proper functioning of the On/Off switch and the fault current protective switch If defects on the safety devices or other defects impairing the operational safety of internal vibrators are observed, the supervisor must be informed immediately. The machine must not be commissioned If there are defects jeopardizing operational safety, the machine has to be switched off immediately The housing tube and the sealing cap are wear parts and must be replaced when the minimum wear measurements have been reached. Refer to the operator's manual for information concerning the wear dimensions for internal vibrators Check the bottom part of the pipe for cracks, damage or loose screw connections. The vibration cylinders are not suitable for use if the bottom part of the pipe is missing Check the clamps on the connections The machine can start to run immediately as soon as it is connected to the mains depending on the switch setting. This is also possible if the switch is defective. SV00042en.fm 7

8 Safety information 2.4 Maintenance Internal vibrators Opening and repairing internal vibrators may only be carried out by trained and authorized technicians Only use original spare parts. Modifications to this machine are subject to the express approval of Wacker. In case of non-observance, all liability shall be refused Disconnect the internal vibrator from the electrical power supply system by pulling out the mains plug before carrying out maintenance and repair work Work on the electric parts of the machine may only be carried out by skilled technicians The green-yellow grounded conductor of the connecting cable must be longer so that it will not be torn off if the strain relief fails. If interrupted, it can cause fatal injury. After conducting repairs, check the grounded conductor for continuity. Double insulated machines and machines with protective low voltage are not provided with a grounded conductor As soon as maintenance and repair jobs have been completed, all safety devices must be properly reinstalled. Screws must be tightened according to the tightening torques specified in the standards Clean the internal vibrator daily. Make sure not to damage the lines when using high pressure washers. 2.5 Transport Secure internal vibrators against falling down during transportation. 2.6 Maintenance checks According to the conditions and frequency of use, internal vibrators must be checked for safe operation by a technician, for example at a WACKER service station, at least once every 6 months and repaired if necessary. Please observe the appropriate rules and regulations valid in your country. SV00042en.fm 8

9 3. Technical data Technical data IRSEN-FU 38 IRSEN-FU 45 Item no. Laser Vibrator head Integrated three-phase AC motor Voltage Frequency Rated current Vibrations Vibrator diameter Vibrator length Vibrator weight (mass) (without hose connection) Effective diameter in concrete kw: V: Hz: A: rpm: mm: in: mm: in: kg: lb: cm: in: ~ , (1.5) 45 (1.8) 345 (14) 382 (15) 2.2 (4.9) 3.5 (7.7) < 50 (20) < 60 (24) Oil type SAE 0W-30 Oil quantity cm 3 : in 3 : 8 (0.5) Inverter / mains connection value Alternating current V: ~ ~ ~ ~ Frequency Hz: 50 / 60 Current A: TD00702en.fm 9

10 Technical data IRSEN-FU 38 IRSEN-FU 45 Power kva: kw: Sound pressure level L pa at operator's station db(a): 79 The weighted effective acceleration value, determined according to EN ISO 5349 m/s 2 : 2.5 These noise and vibration figures were calculated with the internal vibrator being freely suspended in air at the nominal speed of the drive motor. Required cross section for extension of cables TD00702en.fm 10

11 Technical data Item no. Vibrator head IRSEN-FU Integrated three-phase AC motor Voltage Frequency Rated current Vibrations Vibrator diameter Vibrator length Vibrator weight (mass) (without hose connection) Effective diameter in concrete kw: V: Hz: A: rpm: mm: in: mm: in: kg: lb: cm: in: ~ , (2.3) 400 (16) 5.6 (12.3) < 85 (33) Oil type SAE 0W-30 Oil quantity cm 3 : in 3 : 12 (0.7) Inverter / mains connection value Alternating current ~ ~ Frequency 50 / 60 Current 6 12 Power kva: kw: TD00702en.fm 11

12 Technical data Sound pressure level L pa at operator's station db(a): IRSEN-FU The weighted effective acceleration value - measured according to EN ISO 5349 m/s 2 : 2.5 These noise and vibration figures were calculated with the internal vibrator being freely suspended in air at the nominal speed of the drive motor. Required cross section for extension of cables TD00702en.fm 12

13 4. Description Description 4.1 Application The machine is run with single phase current, and is a combination of an internal vibrator and a frequency converter. 4.2 Functional description The power converter assembly of the transformer carries out a rectification of the input voltage. In the inverted rectifier the direct voltage is converted into three-phase alternating current, at the same time increasing the frequency from 50/60 Hz to 200 Hz. The inverted rectifier operates in "pulse-width modulation" which causes a sinusoidal output to be produced as average value which in turn allows fault-proof operation of the units connected. Due to the smooth starting of the units connected, the supply capacity of the transformer can be used completely. The power converter and the inverted rectifier are triggered by means of a control electronics unit with a micro-processor. 50/60 Hz 200 Hz Rectifier 100/115/230/ 240 V D.c.-a.c. converter Electronics Pulse width modulation Sinusoidal average T01036en.fm 13

14 Operation 5. Operation 5.1 Starting up Danger to life Connection: The equipment has been set to its nominal current at the factory. Hook up to single-phase alternating current with 50 or 60 Hz. Assembly instructions for the version without plug receptacle Danger of electrocution! Only a qualified electrician is permitted to assemble the plug and perform a safety check according to the directives in effect. Observe the assembly instructions! Connection: Both voltage and frequency will run up synchronously until they reach their nominal value (soft start) once the equipment has been connected to a power supply; this helps to avoid critical current intensities during start-up. The equipment is suitable for connection to power generators if the generators operating voltage stays within the limits of 230/115 V + 15 %, and if the manufacturer of the generator allows the connection of consumers equipped with capacitors. If possible choose a synchronous generator if the equipment is to be run off a power generator. T01036en.fm 14

15 5.2 Connection using separate extension cable Operation The required cross-section is dependent on the length of the extension cable: Type Length L m Cross-section in mm 2 38/115 < 16 1,5 < 27 2,5 < 43 4 < /230 < 66 1,5 < 110 2,5 < /115 < 12 1,5 < 20 2,5 < 32 4 < /230 < 50 1,5 < 83 2,5 < /115 < 13 2,5 < 21 4 < 32 6 < /230 < 33 1,5 < 55 2,5 < k/230 < 40 1,5 < 66 2,5 < T01036en.fm 15

16 Operation 5.3 Switching off the machine First switch off the equipment. Then pull the mains plug from the socket. T01036en.fm 16

17 Description/maintenance 6. Description/maintenance 6.1 Protection against overheating This machine is protected against overheating by means of a thermal circuit breaker. Every phase is equipped with a separate thermal circuit breaker. If the thermal circuit breaker is activated, switch off the machine and allow it to cool down. 6.2 Maintenance schedule Component Maintenance work Maintenance interval Feed line Visual check - cables and switch box membrane Daily 6.3 Disassembly and assembly Only clamp the Internal vibrator in the lower region of the thick-walled nose cap. a Bottle sizes a k k 105 T01036en.fm 17

18 Description/maintenance 6.4 Maintenance A replacement of the corresponding parts is necessary once the wear measures have been reached. Seal housing components at joint with ergo 4205 and guard against loosening with a welding point. * for IR... 30: Replace complete vibrator head. * for IR... 38/45/57: Connecting lines between hose connection and vibrator head: Make sure to correctly connect the flat connectors (1) and secure them by way of the heat-shrinkable sleeve (2). See illustration. * for IR... 65: Crimp connectors on both sides to connect electric connection lines After opening the vibrator head the correct oil level must be ensured prior to assembly (see technical data). T01036en.fm 18

19 Repair instructions 7. Repair instructions Work on the electric parts of the machine may only be carried out by skilled technicians. 7.1 Repair instructions, faults The equipment may only be opened at least about 5 minutes after the plug was pulled from the socket; this will give the capacitors mounted inside the housing time to dump their charge. Maintenance work may only be carried out be trained personnel. Possible errors: Interruption of the cable connection inverter/vibrating cylinder Insulation error of the inverter, the engine cable or the vibrating cylinder Inverter is overloaded The output stage of the inverter is overloaded due to a short-circuit, ground fault or error in the vibrating cylinder Line input voltage too high / too low Operating control lamp As long as the green LED is lit, the circuit board is electrically charged - even after you switch off the line voltage. The green LED goes out when the condensers are discharged. The diagnostic lamps built into the inverter, five red LEDs and a green LED, help you troubleshoot any problems you may encounter. However, this requires, that you open the inverter housing and apply voltage. This must be carried out by a specialist or a properly instructed employee. T01036en.fm 19

20 Repair instructions There is a risk of injury should a condenser explode when voltage is applied and, as a result thereof, potting compound is ejected. This is why you should always wear eye protection and avoid the area right above the condensers. Before you apply voltage, always carry out a visual inspection of the opened inverter. Condensers with bulged tops or ones that are higher than the others are already damaged. You must not apply voltage to this inverter! If a red LED lights up when you turn on the machine, the machine has shut down because of a detected error. Malfunction Cause Remedy Green LED is not lit. Internal vibrator (IR) not functioning. Green and first red LED light up. IR not functioning. Green and second red LED light up. IR not functioning. Green and third red LED light up. IR not functioning. Green and fourth red LED light up. IR not functioning. Green and fifth red LED light up. IR not functioning. - Supply cable interruption. - Bad contacts. - Cable disruption between frequency converter (FU) and IR. - Defect in the FU electronics. - Short to ground inside the FU or IR. - Temperature inside FU housing. - IR runs sluggish. - Short circuit between FU and IR. - Incorrect input voltage, too high or too low. - Check supply line. - Check contact transitions (switches, connectors) and rework if necessary. - Check cables and replace if faulty. - Replace FU. - Insulation measurements at IR and FU, replace faulty components. - Measure amperages (*) on the output side. - Correct fault in IT. - Locate the short circuit by measurements and remove. - Measure voltage at the switch. - Check generator. (*) - see Technical Data T01036en.fm 20

21 Repair instructions A metal oxide varistor has been included in the input circuit as an additional safety for the equipment against input voltages which are too high. The varistor looks quite similar to a small plate capacitor. Its characteristics are similar to those of a Zener diode (DIN) and it has high currentcarrying capacity. Its resistance of more than 1 MΩ breaks down under extreme circumstances to less than 1 Ω in less than 50 nanoseconds when overloaded. This helps protect the electronic circuitry against high input voltages. The output frequency of 200 Hz out by means of the potentiometer. Fix the adjusting screw of the potentiometer with a drop of paint. T01036en.fm 21

22 Wear dimensions 8. Wear dimensions Machine type Dimensions of the vibrator head and screwed nose caps (mm) øl L L L ø L L IR (30) 347 (353) - - IR (38) 338 (345) 36 (38) 218 IR (45) 372 (382) 42 (45) 333 IR IR... 57k 50 (58) 390 (400) 320 (330) 54,0 (58) 54,0 (58) IR IR... 65k 52 (65) 475(490) 385(400) 58 (65) 58 (65) Measure lengths L and L L at the end of the housing pipe (initial measurements) * Dimensions in bold are wear dimensions. * Dimensions in brackets are original dimensions of new machines. * Replace vibrator head at the latest when the minimum diameter ø (measured in the length L) is reached. * The screwed nose caps must be replaced at the latest when the minimum lengths L L and øl L have been reached. SK00630en.fm 22

23 9. Disposal Disposal 9.1 Environmentally friendly recycling Recycle the machine in an environmentally friendly way observing the regional regulations and directives, e.g. the European Directive for old electrical and electronic equipment. Do not dispose of the machine in household rubbish. It must be disposed of separately. T01088en.fm 23

24 Disposal T01088en.fm 24

25 EC Declaration of Conformity Wacker Construction Equipment AG, Preußenstraße 41, München certifies that the construction machine: 1. Category: 2. Model: 3. Machine type number: Innenvibrator mit Umformer IRFUN 38, IRFUN 45, IRFUN 57 IRSEN-FU 38, IRSEN-FU 45, IRSEN-FU , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , was produced in accordance with the following directives: 98/37/EEC 89/336/EEC 73/23/EEC Please keep this document in a safe place C en.fm Dr. Stenzel Head of Research and Development

26

27 DIN EN ISO 9001 Certificate

28 Wacker Construction Equipment AG Preußenstraße München Deutschland Tel.: +49-(0) Fax: +49-(0) Wacker Corporation P.O. Box 9007 Menomonee Falls, WI USA Tel.: +1(1) Fax: +1(1) Support: Wacker Machinery (HK) Ltd. Skyline Tower, Suite 2303, 23/F 39 Wang Kwong Road, Kowloon Bay Hong Kong Tel.: , Fax:

29

30

INTERNAL VIBRATOR-FREQUENCY INVERTER IRFUN.../ en Operator s Manual

INTERNAL VIBRATOR-FREQUENCY INVERTER IRFUN.../ en Operator s Manual www.wackergroup.com INTERNAL VIBRATOR-FREQUENCY INVERTER IRFUN.../230 0200225en - 10.2002 0007956 100 0008635 100 0007957 100 0008634 100 0007958 100 0008632 100 0008464 100 0008633 100 Operator s Manual

More information

en Converter FU 4/5 Operator s Manual

en Converter FU 4/5 Operator s Manual www.wackergroup.com 0201424en 003 02.2007 Converter FU 4/5 Operator s Manual 1. Foreword Foreword For your own safety and protection from bodily injuries, carefully read, understand and follow the safety

More information

VIBRATORY PLATE DPU 2440F WGB en Operator s Manual

VIBRATORY PLATE DPU 2440F WGB en Operator s Manual www.wackergroup.com VIBRATORY PLATE DPU 2440F WGB 0201436en - 10.2002 0007877 101 Operator s Manual CONTENTS Type Item no. DPU 2440F WGB 0007877... H00396GB 1 2 FOREWORD Foreword For your own safety and

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

Mass Sine 24/10000 Mass Sine 24/15000

Mass Sine 24/10000 Mass Sine 24/15000 USERS- AND INSTALLATION MANUAL Mass Sine 24/10000 Mass Sine 24/15000 Modular high power inverter system MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands ENGLISH: PAGE 1 Tel.: +31-20-342

More information

C3 Operating Instructions

C3 Operating Instructions Version 3.1 Stand 09.2014 Robert Bosch (Australia) Pty. Ltd. 1555 Centre Road Clayton, Victoria 3168 C3 Operating Instructions For further information please contact Bosch at: Australia 1300 30 70 40 www.boschautoparts.com.au

More information

MAR 11 Rev H

MAR 11 Rev H SDE Battery Powered Crimp Tool Kit 1725837- [ ] Customer Manual 409-10053 23 MAR 11 Rev H SAFETY PRES READ THIS FIRST!... 2 1. INTRODUCTION... 5 2. RECEIVING/INSPECTION... 5 3. INSTALLATION/REMOVAL OF

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

Technical Manual Electrical Power Supply System T4002

Technical Manual Electrical Power Supply System T4002 Technical Manual Electrical Power Supply System T400 MOZELT GmbH & Co. KG Please observe the following safety information and recommendations before start-up! Copyright: MOZELT GmbH & Co. KG, D-4769 Duisburg

More information

Technical Documentation

Technical Documentation Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that

More information

18V Cordless Precision Clutch Shut Off Pistol Screwdriver SPC-P2625Q SPC-P2925Q SPC-P21225Q

18V Cordless Precision Clutch Shut Off Pistol Screwdriver SPC-P2625Q SPC-P2925Q SPC-P21225Q 18V Cordless Precision Clutch Shut Off Pistol Screwdriver MODEL NO.: SPC-P2325Q SPC-P2625Q SPC-P2925Q SPC-P21225Q 2 (A) (B) (C) (D) (E) (H) (F) (G) (I) (A) 1/4" Hex with quick change chuck. (B) Covered

More information

VOLT POT 1K R220. OPEN FOR 60 Hz STAB A.V.R. R220. Installation and maintenance

VOLT POT 1K R220. OPEN FOR 60 Hz STAB A.V.R. R220. Installation and maintenance VOLT POT 1K 110 0V E+ E- OPEN FOR 60 Hz STAB This manual concerns the alternator which you have just purchased. We wish to draw your attention to the contents of this maintenance manual. SAFETY MEASURES

More information

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB Operating Instructions Bedienungsanleitung Mode d emploi DW 400 EWB 400 575 EWB 400 575 800 www.bron-kobold.com Operating instructions EWB 400.575 EWB 400.575.800 Before use Please read all the information

More information

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software APC's Back-UPS ES series is now "greener" than ever. The ES 350 utilizes an ultra-efficient design that consumes less power

More information

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL Model 7100 Portable Pin Welder MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL Copyright: March 22, 2005 Revised: December 20, 2016 Gripnail Corporation An Employee Owned Company 97 Dexter Road East Providence,

More information

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures NIGHT-LITE PRO II Electrical System Troubleshooting Guide and Procedures Allmand Bros. Inc. PO Box 888 1502 W. 4 th Ave. Holdrege NE 68949 USA 308-995-4495 Phone 800-562-1373 Toll-Free www.allmand.com

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter Go Power! Manual GP-1750HD Inverter GP-2500 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION...

More information

ARC 1850 LIST OF FIGURES

ARC 1850 LIST OF FIGURES PAGE 1.0 INTRODUCTION... 1 2.0 WARRANTY... 1 3.0 UNPACKING YOUR UNIT... 1 4.0 SUGGESTED SAFETY PRECAUTIONS...... 1 4.1 PERSONAL SAFETY PRECAUTIONS. 1 4.2 POWER SUPPLY SAFETY PRECAUTIONS.. 2 5.0 GENERAL

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

USER MANUAL. Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M

USER MANUAL. Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M USER MANUAL Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M CONTENTS Warning Information 1 3 Introduction 4 Features 4 Getting to know your PS5000M 5-6 Operation 7 Charging before

More information

ALUMAREEL. Electrical Cord Reel. Model EC6 100 Model EC Operational, Maintenance and Installation Manual

ALUMAREEL. Electrical Cord Reel. Model EC6 100 Model EC Operational, Maintenance and Installation Manual ALUMAREEL TM Electrical Cord Reel Model EC6 100 Model EC3 100 Operational, Maintenance and Installation Manual READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS PRODUCT. RETAIN FOR FUTURE REFERENCE 1 P

More information

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only Signal Light Push-button Control Box Gate 2 Gate 1 Contents 1. Important Safety Information 2. Product Description and Application

More information

Mechanical Operating Instructions

Mechanical Operating Instructions Mechanical Operating Instructions SE 5.24 WS / SE 5.24 51172095 / 04.2006 Bau muster Zertifizierung geprüft EN 13241-1 OPERATING INSTRUCTIONS 52210111 consisting of: M : Mechanical Operating Instructions

More information

Instruction Manual For Baldor Buffers

Instruction Manual For Baldor Buffers No. 280F Replaces 280E LB7011 Instruction Manual For Baldor Buffers SAFETY NOTICE: WARNING statements describe conditions that may lead to personnel injury including potentially fatal injuries if the machine

More information

IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT

IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT OPERATING EN INSTALLATION MANUAL IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT Isolation transformer with soft start MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands

More information

MV Series Motors Operation & Parts Manual

MV Series Motors Operation & Parts Manual MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson

More information

Propane torch. Model Assembly And Operation Instructions

Propane torch. Model Assembly And Operation Instructions Propane torch Model 39953 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA

More information

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off. Requires Manual Shut Off. 6 / 2 AMP,, DUAL RATE BATTER TTERY CHARGER 45005 OPERATING INSTRUCTIONS E224783 E224783 Note: 6V Charging Due to continuing improvements, actual product may differ slightly from

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

User manual Pipe notcher Type: AL 1-2E

User manual Pipe notcher Type: AL 1-2E User manual Pipe notcher Type: AL 1-2E Page 1 of 27 Table of contents 1. Foreword... 4 1.1. Name of machine... 4 1.2. Warning... 4 1.3. Target group for each chapter... 4 1.4. Symbols... 4 1.5. Re-ordering

More information

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.

More information

Battery Powered Hydraulic Pump; Kit PN [ ]

Battery Powered Hydraulic Pump; Kit PN [ ] ORIGINAL INSTRUCTIONS Battery Powered Hydraulic Pump; Kit PN 1804111-[ ] Customer Manual 409-10060 16 NOV 16 Rev D SAFETY PRES IMPORTANT SAFETY INFO READ THIS FIRST!... 2 SAFETY PRES AVOID INJURY READ

More information

High Vacuum Diaphragm-Type Dry Vacuum Pump

High Vacuum Diaphragm-Type Dry Vacuum Pump No 腄 26300-2-02-3 High Vacuum Diaphragm-Type Dry Vacuum Pump DTC-120 DTC-120A, 120B, 120C (According to CE) Request to Users Please read this manual thoroughly to ensure safe and effective use of the equipment.

More information

Electrical linear actuator with safety function MC100FSR/24

Electrical linear actuator with safety function MC100FSR/24 Issue 2013-05-24 Operating manual 3.10-TA.210-20-EN Electrical linear actuator with safety function Application Linear actuator with automatic coupling and safety function for fine stroke adjustment of

More information

28W WORK LAMP Model: CTL28 Part No:

28W WORK LAMP Model: CTL28 Part No: 28W WORK LAMP Model: CTL28 Part No: 4002905 INSTRUCTION MANUAL GC0609 INTRODUCTION Thank you for purchasing this CLARKE 28W Work Lamp. Before attempting to use the product, it is essential that you read

More information

EF SERIES MOTORS OPERATION & PARTS MANUAL

EF SERIES MOTORS OPERATION & PARTS MANUAL EF SERIES MOTORS OPERATION & PARTS MANUAL Models S1, S2, S3, S4 S1, S2, S3 S4 EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following motors fully comply with the applicable

More information

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS www.r-techwelding.co.uk MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS 2 Thank you for selecting the R-Tech MMA160S Inverter Arc Welder. The MMA160S has many benefits over traditional Arc welders, including

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

03561 SPEED BOOSTER INSTRUCTION MANUAL. for the Ultra Tugger

03561 SPEED BOOSTER INSTRUCTION MANUAL. for the Ultra Tugger INSTRUCTION MANUAL NRTL/C LR 91904-8 03561 SPEED BOOSTER for the Ultra Tugger Read and understand all of the instructions and safety information in this manual before operating or servicing this tool.

More information

Mounting and Operating Manual Non-Return valves Swing-Check valves

Mounting and Operating Manual Non-Return valves Swing-Check valves Mounting and Operating Manual Non-Return valves Swing-Check valves END-Armaturen GmbH & Co. KG Oberbecksener Str. 78 D-32547 Bad Oeynhausen Telefon (05731) 7900-0 Telefax (05731) 7900-199 http://www.end.de

More information

362 Clamp Meter. Users Manual

362 Clamp Meter. Users Manual 362 Clamp Meter Users Manual PN 3622678 August 2010, Rev. 1, 4/13 2010, 2013 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names

More information

PROPANE TORCH WITH TURBO BURNER

PROPANE TORCH WITH TURBO BURNER PROPANE TORCH WITH TURBO BURNER MODEL 91894 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS INJURY,

More information

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._ Please read these Installation Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. Contents:

More information

Prodigy HDLV Generation II Pump Panel

Prodigy HDLV Generation II Pump Panel Prodigy HDLV Generation II Pump Panel Customer Product Manual Issued 01/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change

More information

Electrical linear actuator with safety function MC100FSR/230

Electrical linear actuator with safety function MC100FSR/230 Issue 2013-05-24 Operating manual 3.10-TA.210-10-EN Electrical linear actuator with safety function Application Linear actuator with automatic coupling and safety function for fine stroke adjustment of

More information

SDS Enclosed Star-Delta Starter User Guide

SDS Enclosed Star-Delta Starter User Guide SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING

More information

18V CORDLESS STAPLER/NAILER

18V CORDLESS STAPLER/NAILER 18V CORDLESS STAPLER/NAILER MODEL NO: CONSN18LI PART NO: 6487055 OPERATION & MAINTENANCE INSTRUCTIONS LS1213 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 120015D OWNERS

More information

CAL/OSHA ELECTRICAL LOW VOLTAGE

CAL/OSHA ELECTRICAL LOW VOLTAGE Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 7 Purpose The purpose of this program is to prevent injuries due to electrical exposure to low voltage (less than or equal to

More information

CORDLESS TACKER MODEL NO: CCT48 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0414

CORDLESS TACKER MODEL NO: CCT48 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0414 CORDLESS TACKER MODEL NO: CCT48 PART NO: 6485070 OPERATION & MAINTENANCE INSTRUCTIONS LS0414 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please read

More information

en Vibroplate VP 1550 (RAW) OPERATOR S MANUAL

en Vibroplate VP 1550 (RAW) OPERATOR S MANUAL www.wackergroup.com 0157759en 001 0703 Vibroplate VP 1550 (RAW) OPERATOR S MANUAL 0 1 5 7 7 5 9 E N VP 1550 (RAW) Table of Contents 1. Foreword 2 2. Safety Information 3 2.1 Laws Pertaining to Spark Arresters...

More information

BODAS Pressure sensor PR3 series 10

BODAS Pressure sensor PR3 series 10 BODAS Pressure sensor PR3 series 10 RE 95155 Edition: 06.2016 Replaces: 05.2015 Measurement ranges to 25, 50, 160, 200, 250, 400, 600 bar Ratiometric output signal 0.5 to 4.5 V with 5 V supply voltage

More information

Back-UPS CS Back-UPS CS 350

Back-UPS CS Back-UPS CS 350 Back-UPS CS Back-UPS CS 350 APC Back-UPS CS, 210 Watts / 350 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, USB Includes: CD with software, Cord management straps, USB cable, User Manual Standard

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS www.r-techwelding.co.uk Email: sales@r-techwelding.co.uk Tel: 01452 733933 Fax: 01452 733939 ProArc 175 INVERTER ARC WELDER OPERATION INSTRUCTIONS Version 2017-10 2 3 Thank you for selecting the R-Tech

More information

MICRO-INVERTER OMNIKSOL M-300

MICRO-INVERTER OMNIKSOL M-300 MICRO-INVERTER OMNIKSOL M-300 TECHNICAL MANUAL CONTENTS INTRODUCTION... 3 SAFETY... 4 SYMBOL ILLUSTRATION... 4 INSTALLATION WARNINGS... 6 PREPARE FOR INSTALLING... 7 TRANSPORT AND INSPECT... 7 CHECK INSTALLATION

More information

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Eclipse Plus VA UPS and Surge Suppressor User s Manual Eclipse Plus 250 250VA UPS and Surge Suppressor User s Manual Compact UPS/Surge Suppressor for Home Office or Small Office Use www.mgeups.com Notes Contents Thank You!.....................................................

More information

Heavy Duty Electric Hydraulic Pumps PN and

Heavy Duty Electric Hydraulic Pumps PN and ORIGINAL INSTRUCTIONS Heavy Duty Electric Hydraulic Pumps PN 69120-1 and 69120-2 Customer Manual 409-1950 27 SEP 16 Rev F SAFETY PRECAUTIONS AVOID INJURY READ THIS FIRST!... 2 1. INTRODUCTION... 3 2. DESCRIPTION...

More information

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

More information

Measurements are expressed in millimeters.

Measurements are expressed in millimeters. T-Rex user manual Measurements are expressed in millimeters. 1 Lamp access 2 Focus adjustment 3 Mounting bracket 4 Swivel locks 5 Clamp hole 6 Air vent 190 285 7 AC input & main fuse 8 Microphone 490 164

More information

PL Submersible, Semi-Vortex, Water Feature Pump

PL Submersible, Semi-Vortex, Water Feature Pump TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and

More information

1329I Integrated Drive/Motor CE Filter Option Kit

1329I Integrated Drive/Motor CE Filter Option Kit Instruction Sheet 1329I Integrated Drive/Motor CE Filter Option Kit CE filter options are designed to be used with the 1329I Integrated Drive/Motor. The main function of the CE filter is to reduce the

More information

GRIMAX 50,75,100,150 S - BRAKE

GRIMAX 50,75,100,150 S - BRAKE B E L T - G R I N D E R S GRIMAX 50,75,100,150 S - BRAKE Table of contents 1. Transport and handling 5 1.1 Transport 5 1.2 Handling 5 1.3 Placing 5 2. Directions 6 2.1 Operation 6 2.2 Safety rules for

More information

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions Reversing contactor universal 2 Contactor / 24V for three- and single- phase motor 51171134 - d 04.2009 OPERATING INSTRUCTIONS 52210115 consisting of: E : Electrical

More information

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax: Go Power! Manual GP-1000 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS

More information

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control User Manual SMC9-11TLRP-BA-en-30 TBEN-SMCTLRP Version 3.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE 3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

Translation of the Original operating instructions Lifting device Z 70 /...

Translation of the Original operating instructions Lifting device Z 70 /... Translation of the Original operating instructions Lifting device Z 70 /... Content 1. Lifting device / Correct use according to regulations 2. Basic principles 3. General information 4. Special remarks

More information

Instructions for Use Plain Trolley ULK Geared Trolley UHK

Instructions for Use Plain Trolley ULK Geared Trolley UHK Instructions for Use Plain Trolley Geared Trolley Item no. Load-carrying capacity (payload) Weight Trolley widths *special trolley widths* Device dimensions mm H / W / D Minimum curve radius mm -005 0,5

More information

R250 A.V.R. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

R250 A.V.R. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9 110 0V E+ E- VOLT STAB KNEE 47.5Hz OFF 9 SPECIAL 8 KNEE 65Hz 7 OFF KNEE 6 57Hz OFF 7 8 50Hz o 9 0 5 6 1 2 3 4 OFF 1 13% 2 25% 3 OFF 4 13% 5 25% 60Hz FREQ. & L.A.M. CONFIG. This manual concerns the alternator

More information

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN CORDLESS WORK LIGHT CORDLESS WORK LIGHT Operation and Safety Notes IAN 288518 GB / IE / NI Operation and Safety Notes Page 5 A HG01386A-BS 5 1 2 6 3 4 7 8 10 9 B C 11 12 13 List of pictograms used...page

More information

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA Installation and operating instructions Solar charge controller 10 A / 15 A / 0 A / 30 A EN 74.86 08.4 1. About this manual These operating

More information

TM SERIES MIXER TMS OPERATION & PARTS MANUAL

TM SERIES MIXER TMS OPERATION & PARTS MANUAL TM SERIES MIXER TMS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC. INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL INS120P TASCO, INC. THIS TESTER IS DESIGNED FOR USE ONLY BY QUALIFIED ELECTRICIANS. IMPORTANT SAFETY WARNINGS mwarning Read and understand this material

More information

4-VOLT LITHIUM-ION AUTO-LOAD SCREWDRIVER w/led WORKLIGHT

4-VOLT LITHIUM-ION AUTO-LOAD SCREWDRIVER w/led WORKLIGHT SKU 241-1394 4-VOLT LITHIUM-ION AUTO-LOAD SCREWDRIVER w/led WORKLIGHT Operation Manual WARNING! Please read this manual before using this product. Failure to do so can result in serious injury. SAVE THIS

More information

Adjustable Speaker Mount GRAVIS 12

Adjustable Speaker Mount GRAVIS 12 Adjustable Speaker Mount GRAVIS 12 User's Manual Translation of the original instructions Version 3.3 Released: 19.01.2017 Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße

More information

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 8 Adjustable Speaker Mount GRAVIS 8 User's Manual Translation of the original instructions Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße 14 D-30179 Hannover TEL +49 (0)

More information

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return

More information

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

7.5 FT PRE-LIT ENGLEWOOD PINE TREE ITEM #0243778 7.5 FT PRE-LIT ENGLEWOOD PINE TREE Holiday Living & Design is a registered trademark of LF, LLC. All Rights Reserved. MODEL #W14L030 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

5.5 FT PRE-LIT SERBIAN SPRUCE TREE

5.5 FT PRE-LIT SERBIAN SPRUCE TREE ITEM #0674086 Holiday Living & Design is a registered trademark of LF, LLC. All Rights Reserved. 5.5 FT PRE-LIT SERBIAN SPRUCE TREE MODEL #W14D0225 Español p. 8 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

362 Clamp Meter. Users Manual

362 Clamp Meter. Users Manual 362 Clamp Meter Users Manual PN 3622678 August 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks

More information

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER SPECIFICATIONS: *Photo for reference only* Part number 8890439 Mode Select: Selects Battery Type Refer to Section 6. IMPORTANT: READ

More information

233 True-rms Remote Display Digital Multimeter Safety Information

233 True-rms Remote Display Digital Multimeter Safety Information 233 True-rms Remote Display Digital Multimeter Safety Information Go to www.fluke.com to register your product and find more information. A Warning identifies conditions and procedures that are dangerous

More information

Installation/Operating Instructions

Installation/Operating Instructions 1000 DE BOSS COMMERCIAL FIXTURE Installation/Operating Instructions 600W 750W 1000W Turbo 825W 1000W 1150W 750W INPUT RC 660W SIG A 600W SIG B www.sunlightsupply.com INCLUDES CONVERTIBLE SMART VOLT DUAL

More information

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0707 SPECIFICATIONS HSE300* HSE360* Model No. HSE130* HSE200A HSE300A HSE360A HSEC400* HSE301A HSE361A Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2

More information

1000mA - 650mA Phase Dimmable LED Driver

1000mA - 650mA Phase Dimmable LED Driver Installation Guide DGLC1000C25PD 1000mA - 650mA Phase Dimmable LED Driver PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU

More information

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8 ITEM #0776 7. FT. PRE-LIT DOUGLAS FIR TREE MODEL #DF-7C8 Español p. 8 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts? Before returning to your retailer, call our

More information

Operating instructions K- Control 4960, 4965, Always on the safe side.

Operating instructions K- Control 4960, 4965, Always on the safe side. Operating instructions Always on the safe side. Vertrieb/distribution: KaVo Dental GmbH Bismarckring 39 D-88400 Biberach Tel.: 0 73 51 / 56-0 Fax: 0 73 51 / 56-14 88 Hersteller/manufacturer: Kaltenbach

More information

A48 / A48B (base plate) BATTERY CHARGER

A48 / A48B (base plate) BATTERY CHARGER A48 / A48B (base plate) BATTERY CHARGER CPN41054 ISSUE DATE: 12315-8/98 ECN/DATE 106 BRADROCK DRIVE DES PLAINES, IL. 60018-1967 (847) 299-1188 FAX: (847)299-3061 15349-07-07/02 16041 6/03 14575-2/01 INSTRUCTION

More information

Type Maxi Mix III Rotary Shaker OPERATION MANUAL AND PARTS LIST SERIES 1046 BARNSTEAD THERMOLYNE

Type Maxi Mix III Rotary Shaker OPERATION MANUAL AND PARTS LIST SERIES 1046 BARNSTEAD THERMOLYNE BARNSTEAD THERMOLYNE Type 65800 Maxi Mix III Rotary Shaker OPERATION MANUAL AND PARTS LIST SERIES 1046 LT1046X1 2/20/98 Model # Voltage M65820-26 230 M65820-26-60 230 M65824 100 M65825 120 M65920 230 Table

More information

BENCH GRINDER MODEL CBG6RZ OPERATING & MAINTENANCE INSTRUCTIONS

BENCH GRINDER MODEL CBG6RZ OPERATING & MAINTENANCE INSTRUCTIONS BENCH GRINDER MODEL CBG6RZ OPERATING & MAINTENANCE INSTRUCTIONS 0100 9 Thank you for purchasing this CLARKE BENCH GRINDER. Before attempting to operate this machine, please read this instruction manual

More information

Wind Power Inverter WINDY BOY 5000A/6000A

Wind Power Inverter WINDY BOY 5000A/6000A Wind Power Inverter WINDY BOY 5000A/6000A User Manual WB5A-6A-BA-BEN114530 TBEN-WB50-60A Version 3.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Manual.........................

More information

Installation/Operating Instructions

Installation/Operating Instructions Installation/Operating Instructions LEC 315 COMMERCIAL ETELLIGENT INCLUDES CONVERTIBLE SMART VOLT DUAL FERRITE POWER CORD easily converts into either a 120 or 208/240 volt 6.5 foot power cord ETELLIGENT

More information

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating Instructions Pedestrian Turnstile Type MPT 33 Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11

More information