MODEL GBW15-22 Yanmar

Size: px
Start display at page:

Download "MODEL GBW15-22 Yanmar"

Transcription

1 REF. PC5105_3St.00 MODEL GBW15-22 Yanmar Water cooling system. Industrial muffler. Set easy to be transported with hand pallet truck. Central lifting point. Complete with engine and battery liquids. Oil draining pipe with cap. TECN NICAL FEATURES PRIME POWER PRP EMERGENCY POWER LTP Frequency Power factor MODEL CODE TBA S200TYA Cos φ 13,4 (10,7) Voltage Volt 400 Fuel capacity Litres 51 Autonomy ( 100% load PRP) DIESEL ENGINE z 13,8 (11,0) 20,9 (16,8) 19,0 (15,2) h 14,2 10,4 Dimensions (LxWx) mm 1.600x870x x870x1.000 Weight kg YANMAR 3TNV88-GGE TNV88-GGE Cooling system Water Water Speed rpm Displacement Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation degree protection c.c n disp. Natural Natural kwm l/h g/kwh Stamford Class alarm Voltmeter. Ammeter. 13,2 PI 044F IP23 Voltage regulation (model) Electronic Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets. Commands shut down Output sockets 3 L Start selector switch with key: OFF - ON* - START. 1 x 400V/16A 3P+N+T CE. 2 x 230V/16A 2P+T CE. PI 144D IP23 Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. 1 x 400V/32A 3P+N+T CE. 1 x Schuko 230V/16A. 4 L 17,7 4,9 Electronic Engine protection: battery charger failure, low oil pressure, high engine temperature. ON*: when selected this position, the system will take some seconds for air perheating by means of a glow plug. The preheating period is lighted by the proper led on the engine protection unit. 3,6 TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Rev.00(Sep2010) Pag. 1 of 2

2 TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE AUTOMATIC CONTROL PANEL (A AMF) Automatic control panel mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set. AUTOMATIC CONTROL PANEL (AMF) Mains Generating set voltage (3 phases). Generator set current (3 phases). Battery Commands and others Remote starting availability. DC system disconnection switch. alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Output and sockets Engine protection: low oil pressure, high engine temperature. Genset protection: under/over voltage, overload, battery voltage out of limits, under/over frequency, start failure. Genereting set voltage (3 phases). Mains Generating set current (3 phases). Digital instrumentation Battery through AC03 control unit. Power (kva - kw - kvar). Power factor Cos φ. Engine speed r.p.m. 1 x 400V/32A 3P+N+T CE Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, control and protection of the generating set. Commands and others Remote starting availability. Acoustic alarm. RS232 Comuncation port. Mains/Genset alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Power output Genset protection: under/over voltage, overload, under/over battery IV poles - 32A. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) PS: PREEATING SYSTEM. Only available for automatic version. LOAD TRANSFER SWITC PANEL. IV poles 32A. Connections Protections Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. Load transfer switch panel built in a metal cabinet and supplied loose Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains from the genset. failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL GENSET. RS232 communication card for ACP Panel Rev.00(Sep2010) Pag. 2 of 2

3 REF. PC5105_3Me.00 MODEL GBW15-22 Yanmar Water cooling system. Industrial muffler. Set easy to be transported with hand pallet truck. Central lifting point. Complete with engine and battery liquids. Oil draining pipe with cap. TECN NICAL FEATURES PRIME POWER PRP EMERGENCY POWER LTP Frequency Power factor MODEL CODE S130TYA S200TYA Cos φ 14,0 (11,2) Voltage Volt 400 Fuel capacity Litres 51 Autonomy ( 100% load PRP) z 14,5 (11,6) 21,7 (17,3) 19,7 (15,8) h 14,2 10,4 Dimensions (LxWx) mm 1.600x870x x870x1.000 Weight kg DIESEL ENGINE YANMAR 3TNV88-GGE 4TNV88-GGE Cooling system Water Water Speed Displacement Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation rpm c.c n disp. Natural Natural kwm g/kwh MeccAlte Class Commands alarm Voltmeter. Ammeter. 13,2 ECP 3 2L degree protection IP23 l/h Voltage regulation (model) Electronic Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets. shut down Output sockets Start selector switch with key: OFF - ON* - START. 1 x 400V/16A 3P+N+T CE. 2 x 230V/16A 2P+T CE ECO 28 1L IP23 Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. 1 x 400V/32A 3P+N+T CE. 1 x Schuko 230V/16A. 4 L 4,9 Electronic Engine protection: battery charger failure, low oil pressure, high engine temperature. ON*: when selected this position, the system will take some seconds for air perheating by means of a glow plug. The preheating period is lighted by the proper led on the engine protection unit. 3 L 3,6 17,7 TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Rev.00(Sep2010) Pag. 1 of 2

4 TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE AUTOMATIC CONTROL PANEL (A AMF) Automatic control panel mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set. Output and sockets AUTOMATIC CONTROL PANEL (AMF) Mains Generating set voltage (3 phases). Generator set current (1 phase). Battery Commands and others Remote starting availability. DC system disconnection switch. alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Engine protection: low oil pressure, high engine temperature. Genset protection: under/over voltage, overload, battery voltage out of limits, under/over frequency, start failure. Genereting set voltage (3 phases). Mains Generating set current (3 phases). Digital instrumentation Battery through AC03 control unit. Power (kva - kw - kvar). Power factor Cos φ. Engine speed r.p.m. 1 x 400V/32A 3P+N+T CE Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, control and protection of the generating set. Commands and others Remote starting availability. Acoustic alarm. RS232 Comuncation port. Mains/Genset alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Power output Genset protection: under/over voltage, overload, under/over battery IV poles - 32A. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) PS: PREEATING SYSTEM. Only available for automatic version. LOAD TRANSFER SWITC PANEL. IV poles 32A. Connections Protections Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. Load transfer switch panel built in a metal cabinet and supplied loose Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains from the genset. failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL GENSET. RS232 communication card for ACP Panel Rev.00(Sep2010) Pag. 2 of 2

5 REF. PC5105_3Li.00 MODEL GBW15-22 Yanmar Water cooling system. Industrial muffler. Set easy to be transported with hand pallet truck. Central lifting point. Complete with engine and battery liquids. Oil draining pipe with cap. TECN NICAL FEATURES PRIME POWER PRP EMERGENCY POWER LTP Voltage Volt 400 Frequency Power factor Autonomy ( 100% load PRP) Dimensions (LxWx) mm 1.600x870x x870x1.000 Weight kg DIESEL ENGINE Speed rpm Displacement MODEL CODE S130TYA S200TYA z Cos φ Fuel capacity Litres 51 YANMAR 3TNV88-GGE 4TNV88-GGE Cooling system Water Water Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation Manual control panel, mounted on the genset and complete of: instrumentation, control, protection and sockets. 13,0 (10,4) 18,6 (14,9) 14,3 (11,4) 20,5 (16,4) h 14,2 10,4 c.c n disp. degree protection IP21 l/h Voltage regulation (model) Compound Commands shut down Output sockets 3, ON*: when selected this position, the system will take some seconds for air perheating by means of a glow plug. The preheating period is lighted by the proper led on the engine protection unit. 3 L Natural Natural kwm g/kwh Linz Class alarm Voltmeter. Ammeter. 13,2 E1S13M/4/13 Start selector switch with key: OFF - ON* - START. 17,7 Engine protection: battery charger failure, low oil pressure, high engine temperature. 1 x 400V/32A 3P+N+T CE. 1 x 400V/16A 3P+N+T CE. 2 x 230V/16A 2P+T CE. 1 x Schuko 230V/16A. 4 L 4,9 E1S13M/4/20 IP21 Compound Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE Rev.00(Sep2010) Pag. 1 of 2

6 TECNICAL CARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZATIONS AND TE PRODUCER RESERVES TE RIGT TO MODIFY TEM FOR INNOVATIONS WITOUT PRIOR NOTICE AUTOMATIC CONTROL PANEL (A AMF) Automatic control panel mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set. Commands and others alarm Output and sockets AUTOMATIC CONTROL PANEL (AMF) Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC03 for monitoring, control and protection of the generating set. Mains Generating set voltage (3 phases). Generator set current (1 phase). Battery Remote starting availability. DC system disconnection switch. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Engine protection: low oil pressure, high engine temperature. Genset protection: under/over voltage, overload, battery voltage out of limits, under/over frequency, start failure. Genereting set voltage (3 phases). Mains Generating set current (3 phases). Digital instrumentation Battery through AC03 control unit. Power (kva - kw - kvar). Power factor Cos φ. Engine speed r.p.m. 1 x 400V/32A 3P+N+T CE Commands and others Remote starting availability. Acoustic alarm. RS232 Comuncation port. Mains/Genset IV poles - 32A. alarm Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery Power output Genset protection: under/over voltage, overload, under/over battery Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WEN ORDERED) PS: PREEATING SYSTEM. Only available for automatic version. LOAD TRANSFER SWITC PANEL. IV poles 32A. Connections Protections Terminals board for power cables connection (Genset-Mains-Load). Contactors mechanically and electrically interlocked. Load transfer switch panel built in a metal cabinet and supplied loose Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains from the genset. failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. RCG: REMOTE CONTROL GENSET. RS232 communication card for ACP Panel Rev.00(Sep2010) Pag. 2 of 2

MODEL GSW Deutz.

MODEL GSW Deutz. MODEL GSW195-220Deutz. REF. PC5214_3St.00 Liquid cooling Diesel engine. Control panel protected by lockable door Internal residential muffler. Detachable central lifting point. Complete with engine and

More information

SG101TDA 102,5 (82,0) 108,1 (86,5) 0, ,6 mm Water. Water n disp. 112,0 l/h 91,1 23,0 28,0 217.

SG101TDA 102,5 (82,0) 108,1 (86,5) 0, ,6 mm Water. Water n disp. 112,0 l/h 91,1 23,0 28,0 217. GENERATING SET TECNICAL GUIDE GSW65-1D Open set z REF. GDS GSW65-1 Deutz cooling system. Industrial muffler. CODE SG740TDA SG101TDA SG141TDA PRIME POWER PRP 74,1 (59,3) 102,5 (82,0) 8,2 (102,6) EMERGENCY

More information

MODEL GSW80 Deutz & 110 Perkins.

MODEL GSW80 Deutz & 110 Perkins. Business Units GENERATORS Product Cards GSW65-80P(zstf) Sound MODEL GSW80 Deutz & 110 Perkins. REF. PC5_3St.00 Liquid cooling Diesel engine. Control panel protected by lockable door Internal residential

More information

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 21.82 Standby power LTP kw 17.46 Prime power PRP kva 19.78 Prime power PRP kw

More information

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1 GBW22Y Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1 Power Rating Standby power LTP kva 14.30 Standby power LTP kw 14.30 Prime power PRP kva 13.00 Prime power

More information

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 32.50 Standby power LTP kw 26.00 Prime power PRP kva 30.50 Prime power PRP kw

More information

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW80P Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 83.00 Standby power LTP kw 66.40 Prime power PRP kva 78.00 Prime power

More information

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro MSW Series 110-705V Mutipurpose, strong and reliable, these generators meet high quality standards. Available in a large range of models to serve the most demanding customer needs. Suitable both for residential

More information

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro MSW Series 110-705V Designed to be multipurpose, strong and user friendly High quality standards High reliability and suitable for numerous applications due to large list of Optional extras Main applications:

More information

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW150P Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 148.00 Standby power LTP kw 118.40 Prime power PRP kva 137.84 Prime

More information

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GMS-015Y Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 14.50 Standby power LTP kw 11.60 Prime power PRP kva 13.88 Prime power

More information

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW145V Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 147.48 Standby power LTP kw 117.98 Prime power PRP kva 132.38 Prime

More information

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3 GSL30D Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 32.50 Standby power LTP kw 26.00 Prime power PRP kva 30.50 Prime power

More information

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1 GSW22P Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1 Power Rating Standby power LTP kva 13.80 Standby power LTP kw 13.80 Prime power PRP kva 13.50 Prime power

More information

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW170I Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 164.00 Standby power LTP kw 131.20 Prime power PRP kva 158.00 Prime

More information

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA) MSW Series 65-220 P Reliable, strong and versatile. With a large list of optional extras, these generators are suitable for many applications. High quality standards guaranteed. Main applications: Construction

More information

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 82.42 Standby power LTP kw 65.94 Prime power PRP kva 74.94 Prime power PRP kw

More information

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 140.21 Standby power LTP kw 112.17 Prime power PRP kva 127.46 Prime power PRP

More information

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW275V Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 275.00 Standby power LTP kw 220.00 Prime power PRP kva 251.48 Prime

More information

P6000s 230V 50Hz #CONN #DPP

P6000s 230V 50Hz #CONN #DPP THE SUPER SILENT POWER Very low noise level, it is the ideal generator to use in quite areas, for residential or rental. It's equiped with a reliable Diesel engine, first class conponents and complete

More information

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GMN - 22P Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 21.50 Standby power LTP kw 17.20 Prime power PRP kva 20.10 Prime power

More information

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14 GMS-110V Power Rating Standby power LTP kva 112.95 Standby power LTP kw 90.36 Prime power PRP kva 101.42 Prime power PRP kw 81.14 Ratings definition (According to standard ISO8528 1:2005) PRP - Prime Power:

More information

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 562.85 Standby power LTP kw 450.28 Prime power PRP kva 509.86 Prime power PRP

More information

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3 GSW275P Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3 Power Rating Standby power LTP kva 275.00 Standby power LTP kw 220.00 Prime power PRP kva 260.47 Prime power PRP kw 208.38

More information

GMR - 67P 67P 09/05/2016 GMR - 067P

GMR - 67P 67P 09/05/2016 GMR - 067P 67P GMR - 67P Generator engineered and designed to work in a wide variety of applications where temporary power supply is needed. Versatility, high efficiency, high structural resistance, high degree of

More information

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW500DO Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 508.23 Standby power LTP kw 406.58 Prime power PRP kva 460.11 Prime

More information

P V 50HZ #CONN #DPP

P V 50HZ #CONN #DPP P4500 230V 50HZ #CONN #DPP THE SILENT POWER Low noise level, it is the ideal generator for use in residential areas or outside normal working hours. It's equipped with a reliable Diesel engine, first class

More information

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1 GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1 Power Rating Standby power LTP kva `18.00 Standby power LTP kw 18.00 Prime power PRP kva 16.00

More information

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 556.96 Standby power LTP kw 445.57 Prime power PRP kva 506.32 Prime power PRP

More information

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GMS - 600V Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 601.00 Standby power LTP kw 480.80 Prime power PRP kva 567.00 Prime

More information

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW415V Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 416.07 Standby power LTP kw 332.86 Prime power PRP kva 379.84 Prime

More information

S V50HZ #AVR #CONN #DPP

S V50HZ #AVR #CONN #DPP S8000 400V50HZ #AVR #CONN #DPP THE COMPLETE PETROL PACKAGE A robust generator with all the features of a top class product: a powerful and economic engine, a strong and modern design and a long-run easy

More information

THE COMPLETE PETROL PACKAGE

THE COMPLETE PETROL PACKAGE S5000 230V50HZ #AVR #CONN #DPP THE COMPLETE PETROL PACKAGE A robust generator with all the features of a top class product: a powerful and economic engine, a strong and modern design and a long-run easy

More information

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GMS - 560V Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 546.00 Standby power LTP kw 436.80 Prime power PRP kva 504.71 Prime

More information

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3 GSW415P Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3 Power Rating Standby power LTP kva 407.78 Standby power LTP kw 326.22 Prime power PRP kva 356.12 Prime power PRP kw 284.90

More information

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW870M Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 871.35 Standby power LTP kw 697.08 Prime power PRP kva 788.14 Prime

More information

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 GSW-705V Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 707.75 Standby power LTP kw 566.20 Prime power PRP kva 636.50 Prime

More information

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP) PRAMAC GBW 45 Item code: SB450TPAY00 Main features Standby : 36 kw power LTP Rated prime : 34 kw power (PRP) Rated : kw continuous power (COP) Phases : 3 Voltage : 400 V Frequency : 50 Hz Engine : Perkins

More information

GE.PK.022/020.SS+0_all

GE.PK.022/020.SS+0_all . Generating Set Diesel +0_all Standard Equipment and features Canopy - Soundproofing Engine Soundproof canopy IP 32 removable High coolant temperature and low oil pressure shutdown system Polyester class1

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42 TECHNICAL SPECIFICATIONS Model: II-044 Gen set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE FPT MODEL F32SM1A CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 40

More information

EN-GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE

EN-GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE EN-GM1606.2 GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE POWER GENERATORS GENERAC FACTORY GENERAC MOBILE PRODUCTS SRL - ITALY GENERAC POWER SYSTEMS, INC. - USA A LEADING ITALIAN COMPANY

More information

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 30 kva STAND-BY POWER: 33 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE ALTERNATOR

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model: IIV85 Generator set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE IVECO MODEL N45TM1A CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1)

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17 Genset with manual control panel. Image for guidance purposes. ENGINE ALTERNATOR MAKE KOHLER MAKE MODEL KDI3404TM MODEL CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) STAND-BY POWER: (LTP Limited

More information

CGT Stamford UCI 274 E1

CGT Stamford UCI 274 E1 PERKINS 1106A-70TAG1 CGT Stamford UCI 274 E1 Generator model: UP-P150S-50 50Hz 3-Phase Power Factor Cos Φ = 0.8 MODEL Standby Power(50Hz) Prime Power(50Hz) UP-P150S-50 118kW / 148kVA 108kW / 135kVA Key

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4 Automatic with amf/ats panel Stand-by Genset V2. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 250 kva STAND-BY POWER: 275 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO

More information

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/ General Characteristics Model Name AJD 33 Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model JOHN DEERE 3029DF128 Alternator Made and Model ECP 28-VL/4 A Control Panel Model 7320 Canopy AK 20 Power

More information

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07 Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 20 kva STANDBY POWER: 22 kva PRP Prime Power norma ISO 85281 LTP Limited Time Power norma ISO 85281 ENGINE ALTERNATOR

More information

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS ELECTRICAL FREQUENCY VOLTAGE PRIME STAND BY 50Hz 3Ph 400/230v 34kVA / 27kW 37kVA / 30kW 50Hz 1Ph 230V 26kVA / 26kW 28kVA / 28kW 60Hz 380/220v 37.5kVA / 30kW

More information

POWER ENGINEERING KVA 50 HZ rpm

POWER ENGINEERING KVA 50 HZ rpm POWER ENGINEERING 6-500 KVA 50 HZ - 1500 rpm INDEX GBA/GSA12L - GBA6D-17D...Open set, air cooled...4 GSA22D-65D...Open set, air cooled... 6 GSA65D...Soundproof, air cooled...8 GSL22D-42D...Open set, oil

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22 TECHNICAL SPECIFICATIONS Model: IVRN-115 Image for guidance purposes. (400 / 230 V) ENGINE ALTERNATOR MAKE VOLVO MODEL MODEL TAD551GE (IIIA) MECC-ALTE ECP 34-2S / 4 CONTINUOUS POWER: (PRP Prime Power norma

More information

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44 Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 150 kva STAND-BY POWER: 165 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE

More information

Standby Amper VOLTAGE

Standby Amper VOLTAGE INTRODUCTION Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32 TECHNICAL SPECIFICATIONS Model: IV-500 Gen set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE VOLVO MODEL TAD 1345 GE CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1)

More information

The GRW Series Designed for rental businesses POWER FOR RENT

The GRW Series Designed for rental businesses POWER FOR RENT The GRW Series Designed for rental businesses POWER FOR RENT GRW Series The GRW series has been conceived to work in a wide variety of applications where temporary power supply is needed. These generators

More information

Standby Amper VOLTAGE

Standby Amper VOLTAGE INTRODUCTION Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime 1 JCB Diesel Generator Technical Specifications Electrical Frequency Phases Voltage Prime Standby Hz Volts kva kw kva kw 50 3 400/230 34.0 27.0 37.0 30.0 50 1 230 34.0 27.0 37.0 30.0 Frequency Hz 50 50

More information

Standby Amper VOLTAGE

Standby Amper VOLTAGE INTRODUCTION Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and

More information

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC This generator set has been designed to meet ISO 88 regulation. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 000//EC Phase Ratings,

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

OptionsChartsGenerators_r1_4_EN. Generators Acronyms And Glossary REFERRING TO LINES GMN GMS

OptionsChartsGenerators_r1_4_EN. Generators Acronyms And Glossary REFERRING TO LINES GMN GMS OptionsChartsGenerators_r1_4_EN GM Generators Acronyms And Glossary REFERRING TO LINES GMN GMS 1 INDEX OF CONTENTS 1. PLUGS & ELECTRONICS: ACP: ETB: SST: SKB1: SKB2: SKB3: SKE: SKC: LTS: Automatic Control

More information

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/ General Characteristics Model Name Frequency (Hz) 50 Fuel Type Diesel Engine Made and Model JOHN DEERE 3029TF129 Alternator Made and Model ECP 32-3S/4 B Control Panel Model 6020 Canopy AK 30 Power (kva)

More information

GE.VO.360/325.SS+0_all

GE.VO.360/325.SS+0_all . Generating Set Diesel +0_all Standard Equipment and features Canopy - Soundproofing Engine Soundproof canopy IP 32 monoblock Engine heater 230 V Polyester class1 soundproofing High coolant temperature

More information

PRODUCT CATALOGUE.

PRODUCT CATALOGUE. PRODUCT CATALOGUE www.pramac.com WORLDWIDE Pramac Group operates through a proprietary distribution network in 15 countries. BUSINESS AREA PRAMAC GENERATORS PRAMAC LIFTER PRAMAC SERVICE & PARTS PRAMAC

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES This generator set is available with CE certification. 3 Phase Ratings, 50 Hz, PF 0,8 Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 Rating (ESP): Prime

More information

1 / Genset general description

1 / Genset general description Measures: L : 1350 mm H : 1200 mm W: 720 mm H Weight: 410 kg W L Hz 50Hz V 400/230V Water cooled Diesel 1500 r.p.m. Open Illustrative image. CE Conformity 1 / Genset general description Engine KOHLER KDW

More information

> PRODUCTS RANGE ENGLISH

> PRODUCTS RANGE ENGLISH > PRODUCTS RANGE ENGLISH The PRAMAC Group represents a solid industrial reality, from manufacturing to commercialization. Its strong international presence has been consolidated in the generators, material

More information

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 130 kva STAND-BY POWER: 145 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE

More information

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00 CUMMINS 30KVA 3 Phase Ratings, 50 Hz, PF 0,8 Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00 Rating (ESP): Prime Rating (PRP): Applicable for supplying power

More information

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00 This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ , INTRODUCTION Water cooled, Diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter and charge alternator Starting battery (with lead acid) including rack

More information

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00 3 Phase Ratings, 50 Hz, PF 0,8 Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 400/230 200,00 160,00 180,00 144,00 259,00 Rating (ESP): Prime Rating (PRP): Applicable for supplying power to varying

More information

1 / Genset general description

1 / Genset general description Measures: L : 3450 mm H : 2140 mm W: 1250 mm Weight: 4147 kg W L H Hz 50 Hz Water cooled 1500 r.p.m V 400/230 V Diesel Open skid CE Conformity illustrative image 1 / Genset general description Engine Alternator

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12 TECHNICAL SPECIFICATIONS Model: ID-095 Stand-by automatic gen set. Image for guidance purposes. (400 / 230 V) ENGINE MAKE DEUTZ MODEL BF4M 1013 E CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 85

More information

Standby Amper VOLTAGE

Standby Amper VOLTAGE INTRODUCTION Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and

More information

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00 cummins diesel 0 kva Phase Ratings, 0 Hz, PF 0,8 Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 00/0 0,00 88,00 00,00 80,00,00 Rating (ESP): Prime Rating (PRP): Applicable for supplying power

More information

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC This generator set has been designed to meet ISO 8528 regulation. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 2000/14/EC 3 Phase

More information

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up. Measures: L: 1300 mm W: 750 mm H: 1160 mm H Weight: W L 257 Kg Hz 50 Hz V 230 V Water cooled illustrative image. 1500 r.p.m Opened 1 / Genset general decription CE Conformity GENERAL TECHNICAL DATA Engine

More information

ENGINE brand Yanmar Yanmar Yanmar Perkins Perkins model 3TNV76 3TNV88 4TNV88 403D-15G 404D-22G Cooling system Water Water Water Water Water

ENGINE brand Yanmar Yanmar Yanmar Perkins Perkins model 3TNV76 3TNV88 4TNV88 403D-15G 404D-22G Cooling system Water Water Water Water Water STATIONARY RANGE / SOUNDPROO VERSION gbw series RIENDLY GENERATION This range has optimized features specially focused to meet the needs of low investment applications. Generators have reduced dimensions

More information

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9 Automatic without ats panel Standby Genset V3. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 10 kva STANDBY POWER: 11 kva PRP Prime Power norma ISO 85281 LTP Limited Time Power norma ISO 85281

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/ This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A MODEL: ERD-100 (DEUTZ BF4M 1013 ECG2 ) 1.500 R.P.M. 50 Hz TECHNICAL SPECIFICATIONS ENGINE MAKE MODEL CONTINUOUS POWER PRP norma ISO 8528-1 DEUTZ BF4M 1013 ECG2 STAND-BY POWER LTP norma ISO 8528-1 ALTERNATOR

More information

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4 TECHNICAL SPECIFICATIONS Model: II-190 Stand-by automatic gen set. Image for guidance purposes. (400 / 230 V) ENGINE MAKE FPT MODEL NEF N67 TM4 CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 170

More information

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER MODEL: ERP-500S (PERKINS 2506A-E15TAG2) 1.500 R.P.M. 50 Hz TECHNICAL SPECIFICATIONS ENGINE MAKE MODEL CONTINUOUS POWER PRP norma ISO 8528-1 PERKINS 2206A-E15TAG2 STAND-BY POWER LTP norma ISO 8528-1 500

More information

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00 This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8 A10 WATER-COOLED SINGLE PHASE 50 HZ NON REQUIRED 97/68 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m. 1.500 Standard Voltage V 230/115 Rated at power

More information

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

KVAR POWERHOUSE RANGE 140 KVA 200 KVA KVAR POWERHOUSE RANGE 140 KVA 200 KVA 50 hz Three phase - 415 v Model Engine Manufacturing Alternat PRP Output ESP Output country of engine or and alternator Kva Kw Kva Kw PM140 1106A-70TG1 ECP34-2L UK

More information

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8 A11 WATER-COOLED SINGLE PHASE 50 HZ NON REQUIRED 97/68 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m. 3.000 Standard Voltage V 230/115 Rated at power

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime 1 JCB Diesel Generator Technical Specifications G331QX Electrical Frequency Phases Voltage Prime Standby Hz Volts kva kw kva kw 50 3 400/230 300.0 240.0 330.0 264.0 Frequency Hz 50 Phases Voltage MCB Rating

More information

DEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG

DEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG 1/5 DEUTZ AG Technical data General engine data Engine Type BF4M2012C EKZ 11372 Speed 1500 min -1 Net frequency Exhaust emission standard 50 Hz Stage II Specific engine data Aspiration No of cylinders

More information