Smart connections. Certificates. PIKO-Inverter
|
|
- Giles Jefferson
- 6 years ago
- Views:
Transcription
1 EN Smart connections. Certificates PIKO-Inverter
2 EU Declaration of Conformity The company KOSTAL Solar Electric GmbH Hanferstraße Freiburg i. Br., Deutschland hereby declares that the inverters PIKO 3.0, PIKO 3.6, PIKO 4.2, PIKO 5.5, PIKO 8.3, PIKO 10.1 PIKO 3.0 DCS, PIKO 3.6 DCS, PIKO 4.2 DCS, PIKO 5.5 DCS, PIKO 8.3 DCS, PIKO 10.1 DCS to which this declaration refers, conform to the following guidelines and standards. and EMC Directive 2004/108/EEC DIN EN :2006 (Harmonic currents) EN : A1: A2:2005 (Flicker) DIN EN :2005 (Interference resistance for industrial environments) DIN EN :2007 (Interference emission for domestic environments) 2006/95/EEC Low Voltage Directive DIN EN 50178:1998 (Electronic devices in high voltage systems) This declaration applies to all identical copies of this product. This declaration loses its validity if the device is modifi ed or incorrectly connected. KOSTAL Solar Electric GmbH Werner Palm Managing Director) This declaration certifies the compliance with the mentioned regulations but does not ensure the properties. The safety instructions in the product documentation provided must be observed!
3 Bureau Veritas E&E Product Services GmbH Businesspark A Türkheim + 49 (0) cps-tuerkheim@de.bureauveritas.com Certificate of compliance Applicant: Product: KOSTAL Solar Electric GmbH Hanferstrasse Freiburg Automatic disconnection device between a generator and the public low-voltage grid Model: PIKO 3.0, PIKO 3.6, PIKO 4.2, PIKO 5.5, PIKO 8.3, PIKO 10.1 Use in accordance with regulations: Automatic disconnection device with three-phase (PIKO 3.0/3.6 single-phase) mains surveillance in accordance with DIN V VDE V : for photovoltaic systems with a three-phase (PIKO 3.0/3.6 single-phase) parallel coupling via an inverter in the public mains supply. The automatic disconnection device is an integral part of the aforementioned inverter. This serves as a replacement for the disconnection device with insulating function which the distribution network provider can access at any time. Applied rules and standards : DIN V VDE V (VDE V ): and Generator at the public low-voltage grid, 4th edition 2001, guideline for connection and parallel operation of generators in the public low-voltage grid with VDN additions (2005) from the German Electricity Association (VDEW) and Association of network operator (VDN). The safety concept of an aforementioned representative product corresponds at the time of issue of this certificate of valid safety specifications for the specified use in accordance with regulations. Report number: 05KFS170-VDE THS186-VDE TH0062-VDE0126 Certificate nummer: U Date of issue: Valid until: Andreas Aufmuth
4 Bureau Veritas Consumer Product Services GmbH Businesspark A Türkheim + 49 (0) cps-tuerkheim@de.bureauveritas.com Certificate of compliance Applicant: Product: KOSTAL Solar Electric GmbH Hanferstrasse Freiburg Automatic disconnection device between a generator and the public low-voltage grid Model: PIKO 3.0, PIKO 3.6 Use in accordance with regulations: Automatic disconnection device with single-phase mains surveillance in accordance with Engineering Recommendation G83/1 for photovoltaic systems with a single-phase parallel coupling via an inverter in the public mains supply. The automatic disconnection device is an integral part of the aforementioned inverter. This serves as a replacement for the disconnection device with isolating function that can access the distribution network provider at any time. Applied rules and standards : DIN V VDE V : (Redundancy) and Engineering Recommendation G83/1. The safety concept of an aforementioned representative product corresponds at the time of issue of this certificate of valid safety specifications for the specified use in accordance with regulations. Report number: 09TH0062-G83 Certificate nummer: U Date of issue: Valid until: Achim Hänchen CERTIFICATION
5 Bureau Veritas E&E Product Services GmbH Businesspark A Türkheim + 49 (0) cps-tuerkheim@de.bureauveritas.com Certificate of compliance Applicant: Product: Model: KOSTAL Solar Electric GmbH Hanferstrasse Freiburg Disconnection device for PV generators Elektronischer DC-Freischalter DCS Use in accordance with regulations: Disconnection between a solar inverter and a photovoltaic generator Applied rules and standards : In dependence on IEC : Corrigendum: A1: Corrigendum 1: A2:2005 DIN EN ; VDE : Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units and IEC : DIN VDE : Electrical Installations of Buildings - Part 7-712: Requirements for Special Installations or Locations - Solar Photovoltaic (PV) Power Supply Systems The safety concept of an aforementioned representative product corresponds at the time of issue of this certificate of valid safety specifications for the specified use in accordance with regulations. Report number: 09TH0063-IEC60947 Certificate nummer: U Date of issue: Valid until: Andreas Aufmuth
6 Test results UNDER / OVER VOLTAGE TESTS Under Voltage Over Voltage Parameter Voltage Time (sec) Voltage Time (sec) Output power level 10% 55% 100% 10% 55% 100% G83/1 Limit 207 V 1,5 s 264 V 1,5 s Actual setting ,1 V ,5 V 165ms 171ms 152ms 185ms 181ms 239ms Trip value 212 V to 202 V 155ms 154ms 172ms 165ms 177ms 177ms 159ms 163ms 158ms 259 V to 269 V 177ms 164ms 206ms 174ms 186ms 172ms 172ms 180ms 179ms 157ms 168ms 168ms 159ms 185ms 173ms UNDER / OVER FREQUENCY TESTS Under frequency Over frequency Parameter Frequency Time Frequency Time Output power level 10% 55% 100% 10% 55% 100% G83/1 Limit >=47 Hz 0.5s <=50.5 Hz 0.5s Actual setting 48,70 Hz 48,70 Hz Hz Hz 128ms 128ms 106ms 85ms 118ms 88ms Trip value 47,50 Hz to 46,50 Hz LOSS OF MAINS TEST 108ms 94ms 96ms 110ms 117ms 101ms 50 Hz to 103ms 96ms 72ms 105ms 103ms 105ms 51 Hz 124ms 102ms 52ms 105ms 103ms 108ms 101ms 98ms 103ms 94ms 100ms 97ms Output power level 10% 50% 100% G83/1 Limit 0.5s Trip value (sec): RECONNECTION TIMES Reconnestion Time Minimum value Actual settings Recorded value Harmonic Current Emissions 95,6ms 103ms 98ms 80,2ms 110ms 90ms 84,2ms 105ms 103ms 89,9ms 96,7ms 85ms 81,9ms 99,7ms 101ms Under/Over voltage Under/over frequency Loss of mains 180 s 180 s 210s Harmonics 2nd 3rd 5th 7th 9th 11th 13th 15 th n 39 th Limit 1,08 2,3 1,14 0,77 0,4 0,33 0,21 0,15 * (15/n) Test value 0,07 0,75 0,21 0,07 0,03 0,02 0,04 <Limit BS EN A Voltage Fluctuations and Flicker (covered by EMC Report) U N =230V, Output power: 100% Starting Stopping Running Limit 4% 4% Pst = 1.0 Plt = 0.65 Test values The stationary deviance of dc% is bigger than the dynamic deviance of dmax at starting and stopping. Limit dc% = 3,3 Pst = 1.0 Plt = 0.65 Test values 2,41 0,0624 0,0624 Power factor G83/1 Limit 0.95 lag-0.95 lead Output Voltage: 212V (U N -8%) 230V 259V (U N +12.7%) Test Value 0,977c 0,976c 0,974c DC injection G83/1 Limit 20 ma Output power: 10% 55% 100% Test Value 4,2 ma 4,0mA 1,9mA
7 Manufacturer s declaration for the operation of PIKO 3.0 and PIKO 3.6 single-phase feed-in solar inverters in photovoltaic systems with type A residual current protection switches: The KOSTAL PIKO solar inverters from the above-mentioned range can be used to safeguard the grid supply with FI protection switches of the type A and to ensure a trigger threshold of I = 100 ma. A residual-current circuit-breaker (Type AC) is suffi cient for the monitoring from the inverter to the building connection point. for the operation of the PIKO 4.2, PIKO 5.5, PIKO 8.3, PIKO 10.1 three-phase in-feed solar inverters in photovoltaic systems with residual protection switches of the type A: The KOSTAL PIKO solar inverters of the above-mentioned range supply power to the grid symmetrically via three network phases. The conversion topology developed for this is characterised by a constant supply of power from the PV generator to the grid, which ensures maximum operation reliability. Permanent residual current is principally avoided due to the inverter s operating features. Switching to the mains grid only takes place after an automatic inspection to ensure sufficient insulation of the PV generator to the grid. A fault in the system would also lead to a fault in the supply of direct current and is immediately prevented by the redundant internal residual current monitoring unit (RCMU) which disconnects it from the grid. The type A residual current devices (RCDs) also installed externally on the grid side are not disrupted due to the inverter in the monitoring unit. The trigger level for operation of 1-3 inverters is 100 ma. For operation of more than 3 inverters, the disconnection threshold is 300 ma. KOSTAL solar inverters conform to the following standards: DIN VDE IEC CEI 64-8/7 KOSTAL Solar Electric GmbH Freiburg, Werner Palm Managing Director
8 Total Harmonic Distortion for PIKO inverters Order PIKO 3.0 PIKO 3.6 PIKO 4.2 PIKO 5.5 PIKO 8.3 PIKO 10.1 n I [A] I [A] I [A] I [A] I [A] I [A] 1 12, ,5607 5,599 7,246 10,793 12, ,0599 0,0669 0,067 0,054 0,068 0, ,6559 0,7498 0,111 0,139 0,142 0, ,0191 0,0162 0,011 0,003 0,021 0, ,2064 0,2089 0,027 0,083 0,058 0, ,0028 0,0018 0,002 0,004 0,02 0, ,0823 0,07 0,087 0,087 0,089 0, ,0024 0,0015 0,009 0,007 0,023 0, ,0314 0,0297 0,073 0,044 0,155 0, ,0024 0, ,004 0,012 0, ,0141 0,0236 0,075 0,032 0,076 0, ,0024 0,0072 0,001 0,006 0,054 0, ,0363 0,0425 0,056 0,037 0,047 0, ,0038 0,0023 0,007 0,002 0,033 0, ,056 0,0555 0,045 0,057 0,103 0, ,0021 0,0054 0,008 0,007 0,014 0, ,0669 0,0664 0,071 0,057 0,067 0, ,0028 0,0057 0,007 0,002 0,034 0, ,0895 0,0892 0,03 0,025 0,066 0, ,0024 0,0048 0,003 0,006 0,023 0, ,0617 0,0596 0,06 0,023 0,066 0, ,0034 0,0065 0,002 0,005 0,016 0, ,0447 0,0461 0,092 0,054 0,123 0, ,0028 0,0034 0,008 0,005 0,017 0, ,0259 0,0295 0,049 0,043 0,083 0, ,0034 0,0023 0,002 0,003 0,005 0, ,0249 0,0283 0,02 0,025 0,024 0, ,0024 0,0049 0,001 0,002 0,007 0, ,0376 0,0496 0,048 0,045 0,069 0, ,0041 0,0088 0,001 0,002 0,004 0, ,0388 0,0646 0,025 0,021 0,04 0, ,0044 0,006 0,003 0,003 0,01 0, ,0349 0,0534 0,006 0,006 0,011 0, ,0031 0,0066 0,006 0,002 0,01 0, ,0153 0,036 0,047 0,013 0,048 0, ,0024 0,0052 0,006 0,003 0,008 0, ,0029 0,0166 0,024 0,01 0,025 0, ,0021 0,0044 0,002 0,001 0,013 0, ,0041 0,004 0,011 0,007 0,005 0, ,0025 0,0024 0,002 0,004 0,007 0,014 KOSTAL Solar Electric GmbH, Werner Palm Managing Director
9 KOSTAL Solar Electric GmbH Hanferstr Freiburg hereby confi rm that the PIKO 3.0, 3.6, 4.2, 5.5, 8.3 and 10.1 inverters demonstrate a good resistance to ammonia. Ammonia concentration, temperature and time play a decisive role. Based on the ammonia contamination levels (max. 20 ppm) specifi ed for agriculture, no impairment to the housing, seals, connecting plug and function of PIKO inverters is to be expected. Freiburg, April 2010 Werner Palm Managing Director
10 KOSTAL Solar Electric GmbH Hanferstr Freiburg i. i. Br. Deutschland Telefon: Fax: KOSTAL Solar Electric Ibérica S.L. Edifi cio abm Ronda Narciso Monturiol y y Estarriol, 3 Torre B, B, despachos 2 y y 3 Parque Tecnológico de Valencia Valencia España Teléfono : : Fax: KOSTAL Solar Electric France SARL 11, rue Jacques Cartier Guyancourt France Téléphone: Fax: KOSTAL Solar Electric Hellas Ε.Π.Ε. 47 Steliou Kazantzidi st., P.O. Box: st building 2nd entrance 55535, Pilea, Thessaloniki Greece / / Ελλάδα Τelephone: Fax: KOSTAL Solar Electric Italia Srl Via Genova, Rivoli (TO) Italia Telefono: Fax: SEM 01-11
Data sheet. PIKO MP plus
Data sheet PIKO 1.5-4.6 MP plus MP PIKO MP plus: the new standard for single-phase inverters, flexible, communicative and with accessories also usable as battery inverter Flexible in use One or two MPP
More informationData sheet PIKO 12-20
Data sheet PIKO 12-20 PIKO inverter: flexible, communicative and practical Flexible in use 3-phase feed-in Up to 3 MPP trackers suited to the layout of almost all roofs Wide input voltage range for flexible
More informationData sheet. PLENTICORE plus. plus
Data sheet PLENTICORE plus plus PLENTICORE plus: The new standard versatile and smart All-in-one PV hybrid inverter with battery input with optional disconnection 1) Compatibility with various high voltage
More informationData sheet PIKO IQ
Data sheet PIKO IQ 4.2-10 IQ PIKO IQ: our power pack flexible, communicative and practical Flexible in use 2 MPP trackers suited to the layout of almost all roofs Extended MPP range perfect for repowering
More informationData sheet PIKO 36 EPC EPC
Data sheet PIKO 36 EPC EPC PIKO EPC: Smart Power Optimised costs and high levels of safety Smart Project Design Optimised generator design with system voltage of up to 1,100 V Integrated KOSTAL Smart AC
More informationOperating Instructions. Planning tool PIKO Plan 2.0 for PIKO Inverter
Operating Instructions Planning tool PIKO Plan 2.0 for PIKO Inverter Legal notice KOSTAL Solar Electric GmbH Hanferstraße 6 7908 Freiburg i. Br. Germany Tel. +49 76 47744-00 Fax +49 76 47744- www.kostal-solar-electric.com
More informationInstallation and Operation manual
Installation and Operation manual PIKO MP plus Legal notice KOSTAL Solar Electric GmbH Hanferstraße 6 79108 Freiburg i. Br. Germany Phone +49 (0)761 477 44-100 Fax +49 (0)761 477 44-111 www.kostal-solar-electric.com
More informationThe new standard. PV hybrid inverter PLENTICORE plus Simple. Versatile. Smart.
The new standard PV hybrid inverter PLENTICORE plus 4.2 10 Simple. Versatile. Smart. KOSTAL competence using energy the smart way. Convincing KOSTAL family p. 3 The new standard p. 4 5 Energy self-sufficiency
More informationKOSTAL solar inverters the right solution for every requirement
KOSTAL solar inverters the right solution for every requirement KOSTAL competence using energy the smart way. Convincing KOSTAL family p. 3 Overview of KOSTAL solar inverters p. 4 7 PIKO MP plus p. 8 9
More informationCertificate of Conformity self-generation unit
Seite 1 von 7 Certificate of Conformity self-generation unit Manufacturer / applicant: Type of power generation unit: SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Grid-tied photovoltaic
More informationCertificate of Conformity self-generation unit
Seite 1 von 7 Certificate of Conformity self-generation unit Manufacturer / applicant: Type of power generation unit: SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Grid-tied photovoltaic
More informationCertificate of Conformity self-generation unit
Seite 1 von 7 Certificate of Conformity self-generation unit Manufacturer / applicant: Type of power generation unit: SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Grid-tied photovoltaic
More informationAS/NZS AS/NZS
TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total
More informationCertificate of Conformity self-generation unit
Seite 1 von 7 Certificate of Conformity self-generation unit Manufacturer / applicant: SMA Solar Technology AG Sonnenallee1 34266 Niestetal Germany Type of power generation unit: Active power (nominal
More informationIncreased requirements on external DC-breakers for transformerless PV inverters in Australia
Increased requirements on external DC-breakers for transformerless PV inverters in Australia Are the requirements also expedient for PV plants with transformerless SMA PV inverters? Content The standard
More informationHarmonic current emissions as EN Harmonic Test Value in Amps % of fund Limit value in Amps
POWER QUALITY Harmonic current emissions as EN 61000-3-2 Harmonic Test Value in Amps % of fund Limit value in Amps 2 0.014 0.143 1.080 3 0.106 1.108 2.300 4 0.003 0.036 0.430 5 0.044 0.463 1.140 6 0.008
More informationSOLAR2PS 500 / 630 / 750 kw Three Phase Solar PV Inverter
SOLAR2PS 500 / 630 / 750 kw Three Phase Solar PV Inverter a new era connecting solar energy General Information Dynamic reactive power control Voltage Dip ride-through capability meets stringent requirements
More informationG83/2 Engineering Recommendation
G83/2 Engineering Recommendation Certificate Number: TR002007 001 Type Approval and manufacturer/supplier declaration of compliance with the requirements of Engineering Recommendation G83/2. Type reference
More informationSolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.
SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy. The convincing solution. We have been developing and producing transformerless inverters for over 20 years. Our engineers
More informationTechnical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids
Technical Data Low Voltage Regulation System LVRSys 1 Power range: 7.5 kva up to 3150 kva 1 Regulation: single- or three-phase 1 Regulation ranges: ± 6 % to ± 24 % 1 Overall efficiency: 99.4 % to 99.8
More informationBraking Devices BR 230/ Assembly- and Commissioning Instructions
electronic Braking Devices BR 230/400-10...400 Assembly- and Commissioning Instructions Quality is our Drive. BR 230/400-10...400 1 as per 04/10 11600.10001 Table of Contents Page 1. Safety notes 3 2.
More informationPIKO BA System smart, communicative and autonomous
PIKO BA System smart, communicative and autonomous KOSTAL competence Using energy smartly. Convincing. KOSTAL family Your trump card for energy generation Solar power around the clock Advantages of PIKO
More informationSMART 1000 / 2000 SERIES
SMART 1000 / 2000 SERIES DC/AC Mobile Hybrid Power Systems AC INVERTER VOLTAGE ADJUSTMENT 220-240V ON OFF 0 100 220-240V / 50Hz C.P. 1.2kW / S.P. 3.3kW 200 AC VOLTAGE Mobile Solutions for Renewable Energy
More informationTEST REPORT DIN V VDE V
Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...
More informationPIKO BA System smart, communicative and independent
PIKO BA System smart, communicative and independent KOSTAL competence Using energy smartly. Convincing. KOSTAL family Your trump card for energy generation Solar power around the clock Advantages of PIKO
More informationGRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS
GRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS Prof. Suryanarayana Doolla Department of Energy Science and Engineering Indian Institute of Technology Bombay OUTLINE Intoduction Grid
More informationCONERGY CIS 1200 Manufactured By Bosch
OFFE RS NE M Y Y IT AL M QU RGY AN CO CONERGY CIS 1200 Manufactured By Bosch AD E E IN G R CONERGY CIS 1200 The innovative central inverter station (CIS series) by CONERGY are manufactured by world leading
More informationTEST REPORT DIN V VDE V
Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...
More informationUTILITY ASPECTS OF GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS
IEA PVPS International Energy Agency Implementing Agreement on Photovoltaic Power Systems Task V Grid Interconnection of Building Integrated and Other Dispersed Photovoltaic Power Systems Report IEA PVPS
More informationNet +Plus Connection Code
Net +Plus Connection Code LANKA ELECTRICITY COMPANY (PRIVATE) LIMITED 1.0 BACKGROUND The existing Net Metering Concept launched in the year 2010 noticed an exponential growth in the recent year and at
More informationSolar Grid tied inverter. Power-One Italy S.p.A. Via S. Giorgio 642, Terranuova Bracciolini (AR) - Italy. P acr [W] P acmax [W]
Seite 1 von 8 Page 1 of 8 Appendix 4 Type of System: System Manufacturer: Manufacturer data: Solar Grid tied inverter Power-One Italy S.p.A. Via S. Giorgio 642, 52028 Terranuova Bracciolini (AR) - Italy
More informationSolarMax MT series. The power pack for maximum yields.
SolarMax MT series The power pack for maximum yields. All good things come in three phases. We have been developing and producing transformerless inverters for over 20 years. Our engineers have effectively
More informationIssue Title Remarks. Instrument transformers See IEC 61869
357 Appendix Norms and Standards As far as norms and standards are mentioned in this book, the respective citation of IEC or DIN EN is given. If IEC-standards or DIN EN-norms are not available, the European
More informationPre-announcement. Transformerless Solar Inverters
Pre-announcement Transformerless Solar Inverters Content About us 2 SOLIVIA - Solar inverters without transformer 4 Solar inverters for residential installations 6 SOLIVIA 3.0 TL 8 SOLIVIA 5.0 TL 10 Solar
More informationManual. BlueSolar Grid Inverter 1500 / / / / / 230
Manual EN BlueSolar Grid Inverter 1500 / 230 2000 / 230 2800 / 230 4000 / 230 5000 / 230 Before you start This manual contains important information regarding installation and safe operation of this unit.
More informationThe Insulation is what counts
Electrical safety as a prerequisite for future electric mobility. NEWSWORTHY The Insulation is what counts Standardisation has a key role to play in e-mobility and also in electrical safety. It is therefore
More information3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR
3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR www.kraus.com www.kraus.com KRAUS RAILWAY TECHNOLOGY PRODUCT LINE Pantograph Switches Trackside Disconnectors Disconnectors & Earthing Switches Pneumatic Interlock
More informationSoftstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions
electronic Softstarter SAS 3...11 SAS 11PUST, 22PUST Assembly- and Commissioning Instructions Quality is our Drive. SAS 3...11, SAS 11PUST, 22PUST 1 Stand 03/17 10800.10002 Table of contents Page 1. Safety
More informationA DEVICE TO INCREASE ENERGY SELF-CONSUMPTION AND SELF-SUFFICIENCY
A DEVICE TO INCREASE ENERGY SELF-CONSUMPTION AND SELF-SUFFICIENCY HOW IT WORKS management of electricity obtained from renewable sources. The operation is simple: convenience is maximum or in case of used
More informationMCS. Important Information on MCS 012 Issue 2.1 for MCS Solar Photovoltaic and Solar Thermal Contractors. Last Updated: 25 th September 2017
MCS Important Information on MCS 012 Issue 2.1 for MCS Solar Photovoltaic and Solar Thermal Contractors Last Updated: 25 th September 2017 1. Publication of MCS 012 Issue 2.1 on 5 th April 2016 Please
More informationNRS 097-series / Grid Code Discussion:
SASGI Meeting: NRS 097-series / Grid Code Discussion: Gerhard Botha Research, Testing and Development 2014/04/16 Overview Introduction What is NRS 097? What do we have? What do we want? Comparison of international
More informationRegenerative Utility Simulator for Grid-Tied Inverters
Regenerative Utility Simulator for Grid-Tied Inverters AMETEK s RS & MX Series with the SNK Option provides the solution Testing of grid-tied inverters used in solar energy systems is emerging as a major
More information* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV
Drive Technology \ Drive Automation \ System Integration \ Services *23582456_0817* Revision MOVIMOT MM..D with AC Motors DT/DV Edition 08/2017 23582456/EN SEW-EURODRIVE Driving the world Amendments/revisions
More informationMAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS
MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important
More informationTHE SELF USE SMART GRID INVERTER NEW GENERATION
Y o u r P o w e r, Y o u r R u l e s THE SELF USE SMART GRID INVERTER NEW GENERATION INVERTER ALL-IN-ONE SYSTEM BACK-UP MANAGEMENT EFFICIENCY (1) INSTALLATION OPERATION & INTERFACE MONITORING ABOUT IMEON
More informationPhotovoltaics. MPI Hybrid Series
Photovoltaics *Also support parallel feature to 3-phase feedback (3 units) MPI Hybrid Series These hybrid solar inverters combine the features of both grid-tied and off grid operations, and allow users
More informationAll-in-one Storage Hybrid System
All-in-one Storage Hybrid System The priority of power supply for battery and AC can be settable; There is no gap to switch between on-grid and off-grid in 0ms,and it will never go offline; Efficient Built-in
More informationABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw
SOLAR INVERTERS ABB string inverters UNODM1.2/2.0/3.3/4.0/4.6/5.0TLPLUS 1.2 to 5.0 kw The new UNODMPLUS singlephase inverter family, with power ratings from 1.2 to 5.0 kw, is the optimal solution for residential
More informationGeneral notes. Operating conditions
1 General notes Wöhner busbar systems and components are the result of expert development based on many years of experience. They have been exhaustively tested and hold many approvals. The correct selection
More informationABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw
SOLAR INVERTERS ABB string inverters UNODM1.2/2.0/3.3/4.0/4.6/5.0TLPLUSQ 1.2 to 5.0 kw The UNODMTLPLUSQ singlephase inverter family, with power ratings from 1.2 to 5.0 kw, is the optimal solution for residential
More informationSTOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:
SolarEdge Single Phase StorEdge TM Solutions for North America 12-25 STOREDGE TM SolarEdge StorEdge Solutions Benefits: More Energy - DC-coupled architecture stores PV power directly to the battery without
More informationQuick Installation Guide. RPI H3 Flex (H3_210) United Kingdom
Quick Installation Guide RPI H3 Flex (H3_210) Europe United Kingdom This quick installation guide applies for the following inverter models: RPI H3_210 (Delta part number RPI302RH210000) The Delta part
More informationINGECON SUN PowerMax B SERIES. A new generation of central photovoltaic inverters
INGECON SUN PowerMax B SERIES A new generation of central photovoltaic inverters INGECON SUN PowerMax - B Series Main features of Ingeteam s central PV inverters The greatest power density on the market:
More informationEaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC
Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-19065-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2017-11-22 to 2022-11-21 Date of issue: 2017-11-22
More information/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE
Perfect Welding Solar Energy Perfect Charging FRONIUS SYMO HYBRID The personal storage solution for 24H Sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic Peak
More informationFeatures. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter
Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation
More informationBANGALORE ELECTRICITY SUPPLY COMPANY LIMITED
GUIDELINES FOR EMPANELMENT OF GRID TIED INVERTER MANUFACTURERS FOR IMPLEMENTATION OF SRTPV PROGRAM IN BESCOM. I. NEW EMPANELMENT 1. The grid tied inverter manufacturer shall register their application
More information3. Customer shall provide space for metering equipment and meter base as per Springville City Power requirements.
A. General This Customer-Owned Generation Standards for Customer-Owned Grid Connected Electric Generating Systems sets forth the requirements and conditions for interconnected non-utility-owned electric
More informationABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw
Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw REACT stores and allows you to make the most of the energy produced by your photovoltaic system. REACT is an innovative photovoltaic inverter,
More informationString Inverter (SUN KTL-A)
String Inverter (SUN2000-30KTL-A) Smart Maximum of 3 MPPT for versatile adaptions to different module types or quantities built up with different alignments 6 strings intelligent monitoring and 80% time
More informationEnergy Storage System for Home
Energy Storage System for Home Energy Self-Consumption - Daytime: Stored energy generated by Solar Panel. - Nighttime: Discharge stored energy for home use. High Efficiency - Peak efficiency 97.3% Bi-directional
More informationA permanent supply in any environment today and in the future High performance power supplies fit for digitisation Let s connect.
A permanent supply in any environment today and in the future High performance power supplies fit for digitisation Let s connect. Power supply Supplying power even under difficult environmental conditions
More informationEnergy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter
Energy Storage System for Home Energy Self-Consumption - Daytime: Stored energy generated by Solar Panel. - Nighttime: Discharge stored energy for home use. Peak Hours Shaving - Reducing electricity consumption
More informationCatch Eco Range : Technical Specification Sheet
Catch Eco Range : Technical Specification Sheet Battery Hybrid Inverter AC Coupled Inverter Lithium phosphate technology High cycle life with warrantied throughput Indoor and outdoor options (IP21 and
More informationEffective discrimination of protective devices
Effective discrimination of protective devices In the event of a fault occurring on an electrical installation only the protective device nearest to the fault should operate,leaving other healthy circuits
More informationSTOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:
SolarEdge Single Phase StorEdge TM Solutions for North America 12-20 STOREDGE TM SolarEdge StorEdge Solutions Benefits: More Energy - DC-coupled architecture stores PV power directly to the battery without
More information500 / 630 / 720 / 760 / 800 / 850 / 900
SUNNY CENTRAL STORAGE 500 / 630 / 720 / 760 / 800 / 850 / 900 SCS 500 / SCS 630 / SCS 720 / SCS 760 / SCS 800 / SCS 850 / SCS 900 Durable Full nominal power in continuous operation at ambient temperatures
More information/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE
Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic
More informationMINI MCR-SL-UI-UI(-SP)
Configurable 3-Way Isolating Amplifier Data Sheet 11/2004 Product Description Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP) is used to electrically isolate, condition, amplify,
More informationMINI MCR-SL-UI-UI(-SP)(-NC)
Configurable 3-Way Isolating Amplifier Data Sheet 04/2005 Functions Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP)(-NC) is used to electrically isolate, condition, amplify,
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw
SOLAR INVERTERS ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw REACT stores and allows to make the most of the energy produced by a residential photovoltaic system. 01 01 REACT-3.6/4.6-TL PV + Storage
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationCommercialized storage solutions for enhanced grid operation
Commercialized storage solutions for enhanced grid operation Dr. Andreas Luxa Principal Expert, Low and Medium Voltage Division, Amsterdam The power grid is in transformation: Increasingly complex source/generation
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationOUTPUT SHORT-CIRCUIT CURRENT BEARABLE BY THE UPS
OUTPUT SHORT-CIRCUIT CURRENT BEARABLE BY THE UPS Abstract According to the standards, an overcurrent is a current which exceeds its rated value. Overcurrents can arise in different modalities, depending
More informationINVERTER APPROVAL FOR INSTALLATION IN ISRAEL
05.02.18 v.5 INVERTER APPROVAL FOR INSTALLATION IN ISRAEL STANDARDS APPLIED FOR SAFETY EVALUATION OF INVERTERS: AS/NZS 3100 Approval and test specification General requirements for electrical equipment
More informationELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH
HH DRIESCHER - High-voltage high breaking capacity fuses from 1 kv up to 36 kv HH HH ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-866 MOOSBURG TEL. +9 87 61 6 81-0 FAX +9 87 61 68 11 37 http://www.driescher.com
More information013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS
013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification
More informationgi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories
,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker
More informationDEPARTMENT OF TRADE AND INDUSTRY NO APRIL 2016
Trade and Industry, Department of/ Handel en Nywerheid, Departement van 438 National Regulator for Compulsory Specifications Act (5/2008): Amendments to the Compulsory Specification for Earth Leakage Protection
More informationE-15 Uninterruptible Power Systems (UPS)
Guideline No.E-15 (201705) E-15 Uninterruptible Power Systems (UPS) Issued date: May 9, 2017 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical requirements,
More informationTechnical Requirements for Renewable Energy Power System
Hotline: 2843 3228 Email address: RE@hkelectric.com Issued on 20 Nov 2018 1. Introduction 1.1. This document aims to provide the technical requirements for renewable energy power system (the REPS) connected
More information10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph
VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery
More informationBraking Devices VB 230/ Assembly- and Commissioning Instructions
electronic Braking Devices VB 230/400-40... 600 Assembly- and Commissioning Instructions Quality is our Drive. VB 230/400-40... 600 1 as per 05/15 19700.10001 Table of Contents Page 1. Safety notes 3 2.
More informationINVEOR "Smart connections." on five levels
INVEOR "Smart connections." on five levels 1 The Inveor 3 Operation and observation IP65 protection class Integrated soft PLC Pre-fitted cable glands Fan-free design up to 7.5 kw Robust and vibration-resistant
More informationSolarMax P series The power package for residential solar plants
SolarMax P series The power package for residential solar plants The future-proof solution The requirements for residential photovoltaic plants have increased continuously in the past years. Due to our
More informationTechnical information No. 01. IT systems. The basis for reliable power supply
IT systems The basis for reliable power supply FA01en/01.2004 IT systems The basis for reliable power supply in critical areas The advantages of sophisticated industrial systems can only be of use, if
More informationElectric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT
Date of publication: 1 November 2016Not yet published Issued by: Mark Wogan, Manager Energy Safety WorkSafe New ZealandNot yet issued Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals
More informationAXIAL FANS Axis / Tubo OPERATION MANUAL
TUBO-M AXIS-QA AXIS-Q AXIS-QR AXIS-F AXIS-QRA AXIAL FANS Axis / Tubo OPERATION MANUAL Axis / Tubo www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements
More informationSTOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:
SolarEdge Single Phase StorEdge TM Solutions for North America 12-25 STOREDGE TM SolarEdge StorEdge Solutions Benefits: More Energy - DC-coupled architecture stores PV power directly to the battery without
More informationNet Metering Interconnection Requirements
Net Metering Interconnection Requirements Customer Generation Capacity Not Exceeding 100 kw Date: 2017-07-01 Version: 1 Revision History Date Rev. Description July 1, 2017 1 Initial Release Newfoundland
More informationE-15 Uninterruptible Power Systems (UPS)
Guideline No.E-15 (201510) E-15 Uninterruptible Power Systems (UPS) Issued date:20 October, 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements,
More informationTechnical specifications
xstorage Home Technical specifications System overview The following Table 1 provides a general overview of battery capacity and inverter power range combinations that can be integrated together with the
More informationAPPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.
TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION Abstract This application note describes the four quadrant mode of operation of a linear AC Power
More informationConsequences on Grid Operation by Decentralized Renewable Power Generators
Fakultät für Informations- Medien- und Elektrotechnik Consequences on Grid Operation by Decentralized Renewable Power Generators Consideration in the German Low Voltage and Medium Voltage Directive and
More informationTechnical Standard - TS 129. Small Inverter Energy Systems (IES) - Capacity not exceeding 30kW. SA Power Networks. Published: November 2017
TS 130: Inverter Energy Systems (IES) - capacity up to or equal to 200 kw Technical Standard - TS 129 Small Inverter Energy Systems (IES) - Capacity not exceeding 30kW Published: November 2017 SA Power
More information/ Optimised energy management. / Dynamic Peak Manager. / Smart Grid Ready 12.0 A / 12.0 A 18.0 A / 18.0 A
/ Perfect Welding / Solar Energy / Perfect Charging FRONIUS PRIMO / Optimised energy management. N W E S / SnapINverter Technology / Integrated data communication / SuperFlex Design / Dynamic Peak Manager
More informationCommissioning Instructions Inbetriebnahme Anleitung VB 230/ L (LP)
Commissioning Instructions Inbetriebnahme Anleitung VB 230/400-25 L (LP) Quality is our Drive. Qualität ist unser Antrieb. VB230/400-25L (LP) 1 as per 03/06 1B000.10001 Table of Contents Page 1. Safety
More information