Existalite ZV 4-pole self-contained emergency lighting conversion module

Size: px
Start display at page:

Download "Existalite ZV 4-pole self-contained emergency lighting conversion module"

Transcription

1 Lamp Compatibility T8 T12 TC-SEL Existalite ZV 4-pole self-contained emergency lighting conversion module Existalite ZV : a range of compact, economical conversion modules specifically developed to operate self-contained fluorescent lamps in emergency mode. Compatible with the majority of standard 4-pin switch start fluorescent lamps, Existalite ZV modules incorporate highly efficient DC-AC inverter circuits to ensure emergency operation at optimum battery voltages. TC-DEL Available as standard as conversion module with battery for integration into existing mains fluorescent lamps, or fully assembled remote conversion kit to special order for installations where space or temperature restrictions make integral conversions impossible. TC-DD U

2 Existalite ZV 4-pole self-contained emergency lighting conversion module Connection to lamp circuit via 4-pole changeover device 3 hour emergency duration as standard (1 hour to special order), with 24 hour recharge Constant current charge circuit with battery deep discharge protection Supplied with IDC/push-wire terminals suitable for automated and manual assembly CE marked and in compliance with the EMC Directive Electronic circuitry conforms to the relevant IEC standards Technical specification : Mains voltage Mains frequency Mains current Charge current Charge indicator Emergency duration Recharge period ZV Vac 50/60 Hz 40 ma 200 ma nominal Green LED 3 hours as standard (1 hour to special order) 24 hours Changeover voltage In compliance with EN Module case temperature range Ingress protection Safety class Weight Case material Approvals Dimensions Remote enclosures 0-70 C at 25 C room ambient temperature IP20 I kg Zinc galvanized steel Conforms to the safety and performance requirements of IEC , IEC and IEC 925. CE marked Fixing Centres 148 mm Remote conversion kits are available to special order for use where luminaire internal temperatures are too high, or luminaires have insufficient internal room for the conversion module and battery. For availability of remote enclosures, contact Technical Sales. Details of our standard IP20 rated enclosure is shown for reference - for kits in other formats/ip ratings, contact Thomas & Betts to discuss your particular requirements. Technical specification : Wiring Cable entry Mounting Case material Dimensions 30 mm 42 mm Standard IP20 enclosure 155 mm 1.2 m colour-coded high temperature single core cable with terminals and 0.5 m protective loom 20 mm cut-out Two fixing holes in base Zinc plated steel 44 mm 431 mm 112 mm ZV page 2

3 Existalite ZV 4-pole self-contained emergency lighting conversion module Product selection Existalite ZV conversion equipment can be ordered as separate individual components or complete kits, dependent on your specific project requirements. To establish your full requirement, use the correct module prefix from the BLF chart, then determine: Supply preference: module and battery as separates, or integral module kit (remote kits are to special order) Battery configuration for integral conversions: 'stick' battery types are available as standard; 'side by side' batteries are to special order - contact Thomas & Betts for further information The final product order code can then be established from the product table, right. If you require further assistance regarding installation and wiring of conversion modules to specific lamp types, please contact Thomas & Betts on +44 (0) Module Prefix Number of batteries Ordering as separates Base module Battery codes Ordering as kits Integral module + battery ZV3EA 3 ZV3EAI-GRN BTF078 ZV3EAKB-GRN ZV3EB 3 ZV3EBI-GRN BTF078 ZV3EBKB-GRN ZV3FA 4 ZV3FAI-GRN BTF030 ZV3FAKB-GRN ZV3FB 4 ZV3FBI-GRN BTF030 ZV3FBKB-GRN ZV3GA 5 ZV3GAI-GRN BTF040 ZV3GAKB-GRN Modules are supplied with green LED including 1 m connecting leads as standard. For remote enclosure mounted equipment & alternative battery configurations, contact Technical Sales for availability. Stick Note: ZV modules for use with switch start ballasts ONLY. We do not recommend use with HF ballasts.. Stick Important note To maintain compliance with the requirements of EN we recommend conversion equipment is connected to Existalite approved batteries as specified in the product selection table. Conversion notes 1. All emergency lighting conversions should be undertaken in accordance with relevant national requirements and codes of practice, including ICEL Converted luminaires should comply with EMC and Low Voltage Directives in order to carry the CE mark. 3. When remote mounting, the connecting cable between the lamp and the module/battery should not exceed 1 m. page 5 ZV

4 Batteries Existalite ZV conversion modules can be supplied with advanced high temperature Nickel Cadmium (NiCad) batteries which, when properly installed in compliance with the EN product standard, are designed to give a minimum of 4 years service life. Batteries are available in a range of configurations for optimum use of space within the luminaire. Side by side battery sticks of the same size (e.g. 2 x 2 cell, 2 x 3 cell etc.) can be slotted together by the end caps, permitting batteries to be fixed using only 2 screws. Technical specification : Batteries Battery High temperature Nickel Cadmium Battery temperature (continuous) 0-55 ºC Service life Minimum 4 years (when installed in compliance with EN ) Battery voltage per cell 1.2 V Capacity 4 Ah Connectors Non-reversible, with 200 mm leads as standard (other lengths supplied to special order) Configurations Stick : 1 x 3 cell, 1 x 4 cell, 1 x 5 cell Side by side* : 2 x 2 cell, (1 x 2) + (1 x 3) cell Termination Battery end caps fitted as standard on stick and side by side battery configurations Weight 3 cell : 0.4 kg. 4 cell : 0.5 kg. 5 cell : 0.8 kg Dimensions 2 cell 3 cell 4 cell 5 cell Length (mm) Fixing centres (mm) mm 35 mm length length 77.5 mm 39.5 mm * Side by side batteries are to special order - contact Thomas & Betts. page 3 ZV

5 Existalite ZV 4-pole self-contained emergency lighting conversion module Ballast Lumen Factor (% of normal lamp output lumens) The chart shown right establishes the ballast lumen factor of Existalite ZV integral conversion modules and remote conversion kits. A range of modules is available, to ensure optimum starting and operation of the various fluorescent lamp types and wattages available, for best long-term lamp performance. The required number of battery cells for each lamp is also shown. To select the correct module, cross reference the lamp type to be converted with the relevant module code prefix to achieve the stated BLF (e.g. ZV3FA module prefix converts a 51 W T8 lamp to emergency use, with 3 hour duration and providing a BLF of 6%). Once the module prefix is established, your full order requirement (either as separates or kits) can be determined using the product selection table, shown over the page. Module type 3 Hr duration ZV3EA ZV3EB ZV3FA ZV3FB ZV3GA Battery cells Lamp type - T8 18 W 7 T8 30 W 8 T8 36 W 8 T8 58 W 6 T8 70 W 7 T8 16 W 7 T8 32 W 8 T8 38 W 8 T8 51 W 6 T12 20 W 9 T12 30 W 8 T12 40 W 7 T12 65 W 7 TC-DEL 10 W 9 TC-DEL 13 W 9 TC-DEL 18 W 7 TC-DEL 26 W 9 TC-SEL 5 W 13 TC-SEL 7 W 15 TC-SEL 9 W 10 TC-SEL 11 W 10 TC-DD 10 W 12 TC-DD 16 W 15 TC-DD 21 W 10 U 20 W 9 U 40 W 7 For alternative lamp types not shown above, please contact Thomas & Betts. page 4 ZV

6 UK OFFICE Thomas & Betts Limited Existalite Bruntcliffe Lane Leeds West Yorkshire LS27 9LL Tel +44 (0) Fax +44 (0) EUROPEAN HEADQUARTERS Thomas & Betts European Centre SA 200 Chaussée de Waterloo B-1640 Rhode-St-Genèse Belgium Tel +32 (0) Fax +32 (0) MIDDLE EAST OFFICE Thomas & Betts Ltd. Br. Office 724 6WA West Wing Dubai Airport Free Zone PO Box Dubai United Arab Emirates Tel +971 (0) Fax +971 (0) SOUTH EAST ASIA OFFICE Thomas & Betts Asia (Singapore) Pte Ltd 10 Ang Mo Kio Street 65 #06-07 Techpoint Singapore Tel Fax BSI U K A S QUALITY MANAGEMENT 003 FM09470 A member of the LIGHTING INDUSTRY FEDERATION The content of this Thomas & Betts publication has been carefully checked for accuracy at the time of print. However, Thomas & Betts doesn t give any warranty of any kind, express or implied, in this respect and shall not be liable for any loss or damage that may result from any use or as a consequence of any inaccuracies in or any omissions from the information which it may contain. E&OE. Copyright Thomas & Betts Corp Copyright in these pages is owned by Thomas & Betts except where otherwise indicated. No part of this publication may be reproduced, copied or transmitted in any form or by any means, without our prior written permission. Existalite is a brand owned by Thomas & Betts. Images, trade marks, brands, designs and technology are also protected by other intellectual property rights and may not be reproduced or appropriated in any manner without written permission of their respective owners. Thomas & Betts reserves the right to change and improve any product specifications or other mentions in the publication at its own discretion and at any time. These conditions of use are governed by the laws of the Netherlands and the courts of Amsterdam shall have exclusive jurisdiction in any dispute. TBEX-ZV-1011

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose OEM Emergency Portfolio Product Guide Emergency components for LED, fluorescent and auxiliary purpose Contents Introduction to this guide 3 LED Modules 4 PHL-EL3 PHL-EL3-80 PHL-EL3-D PHL-EL3-D80 PHL-EL3-4

More information

Emergency lighting units EM INVERTER

Emergency lighting units EM INVERTER T5 T8 TC-DEL TC-SEL TC-TEL TC-L TC-DD EM, 230 240 V 50/60 Hz version Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps Small dimensions (28

More information

Combined ballast. Combined ballast XCU 16 XCR 17 XHF Batteries 20. Combined ballast.

Combined ballast. Combined ballast XCU 16 XCR 17 XHF Batteries 20. Combined ballast. Combined ballast Combined ballast XCU 16 XCR 17 XHF 18-19 Batteries 20 15 Combined ballast XCU The XCU combined units together with the appropriate inverter circuits For Linear and TC-L fluorescent lamps

More information

Emergency lighting units PC COMBO

Emergency lighting units PC COMBO TC-DD PC CFL E COMBO, 230 240 V 50/60 Hz Compact fluorescent lamps Product description Combination of electronic ballast and emergency lighting unit For TC-DD compact fluorescent lamps For manual testing

More information

BASKET TRAY SYSTEM WITH PREFAB FITTINGS

BASKET TRAY SYSTEM WITH PREFAB FITTINGS BASKET TRAY SYSTEM WITH PREFAB FITTINGS SM Cut Time, Not Corners with QuickTurn Prefab Fittings QuickTurn prefab fittings save you time and money. Cutting fittings for basket tray installation is labor-intensive

More information

Product Catalogue. Conduit Systems & Accessories

Product Catalogue. Conduit Systems & Accessories Product Catalogue Conduit Systems & Accessories Introduction Welcome to Thomas & Betts At Thomas & Betts, our focus is on improving your business performance by providing practical, reliable electrical

More information

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing ( x 0 mm cross-section) Properties or h rated duration Compatible with all

More information

EM BASIC V 50/60 Hz

EM BASIC V 50/60 Hz T, T, TCDD, TC, TCE, TCDE, TCTE linear and compact lamps 00 V 0/0 Hz RoH 0 00 Description: Emergency lighting modules with hour or hour duration. Five pole technology = pole changeover and a delayed action

More information

MANUFACTURED IN THE UK

MANUFACTURED IN THE UK The Galileo II range of decorative, wall or ceiling mounted luminaires, are as versatile as they are attractive. The range is available in two body sizes, 350mm and 425mm diameter, and in a variety of

More information

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No The Galileo II range of decorative, wall or ceiling mounted luminaires, are as versatile as they are attractive. The range is available in two body sizes, 350mm and 425mm diameter, and in a variety of

More information

Emergency lighting units PC COMBO

Emergency lighting units PC COMBO T5 PC, 220 240 V 50/60 Hz Linear fluorescent lamps Product description Combination of electronic ballast and emergency lighting unit For T5 fluorescent lamps Low-profile casing (21 x 30 mm cross-section)

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For T fluorescent lamps ow-profile casing ( x 0 mm cross-section) -year guarantee Properties or h rated

More information

DALI 650mA LED Driver

DALI 650mA LED Driver Installation Guide DGLC650C18DD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095

More information

UL AND CODE COMPLIANCE

UL AND CODE COMPLIANCE BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency

More information

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version T T TC-DE TC-SE TC-TE TC-F TC- TC-DD Tc EM, 0 40 V PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent lamps

More information

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years 2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years The Trojan range of energy efficient bulkhead fittings are manufactured with a polycarbonate

More information

MANUFACTURED IN THE UK

MANUFACTURED IN THE UK The Trojan range of energy efficient bulkhead fittings are manufactured with a polycarbonate base and diffuser. Together with a poured gasket the Trojan leads vandal-resistant IP65 technology. With a hinged

More information

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination APPLICATION The BAL1400 fluorescent emergency ballast works in conjunction with the AC ballast to convert

More information

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST APPLICATION The BALT5-800 low-profile fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures

More information

Arla Foods, Aylesbury Litex LED IP65. 2 Industrial and Hazardous Area

Arla Foods, Aylesbury Litex LED IP65. 2 Industrial and Hazardous Area Litex LED IP20 Arla Foods, Aylesbury Litex LED IP65 2 Industrial and Hazardous Area Litex LED IP20 This versatile industrial LED luminaire is ideally suited to all industrial and warehouse applications.

More information

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version T5 T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD T5c EM SEFTE, 220 240 V SEFTEST version Product description Emergency lighting supply unit with self-test function For linear and compact fluorescent lamps ow-profile

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4 Data sheet Integrated emergency converter for fluorescent lamps zone 2 Ex 100,000 h suitable for zone 2 hazardous areas For mains and battery supply Integrated battery management inear V inear V Emergency

More information

LE Fluorescent Ballast

LE Fluorescent Ballast HF-PERFORMER II Electronic ballasts (flat) for TL5 lamps Definition Flat, Slim, lightweight highfrequency electronic ballast for TL-5 fluorescent lamps, based on EII technology. Description The combination

More information

SPARES POCKET LIGHTING GUIDE FREE DELIVERY SUPPORT 390 STORES 35,000 ITEMS. For more great deals visit cef.co.uk 8AM TO 8PM MON-FRI NATIONWIDE LOCALLY

SPARES POCKET LIGHTING GUIDE FREE DELIVERY SUPPORT 390 STORES 35,000 ITEMS. For more great deals visit cef.co.uk 8AM TO 8PM MON-FRI NATIONWIDE LOCALLY LIGHTING SPARES POCKET GUIDE 390 STORES NATIONWIDE 35,000 ITEMS IN STOCK ONLINE SUPPORT 8AM TO 8PM MON-FRI FREE DELIVERY LOCALLY For more great deals visit cef.co.uk All products are subject to availability

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing (21 x 30 mm cross-section)

More information

Central Battery Systems Loadstar AC/DC Systems

Central Battery Systems Loadstar AC/DC Systems The Loadstar range of AC/DC central battery units comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources of emergency power for escape

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing

More information

650mA Phase Dimmable LED Driver

650mA Phase Dimmable LED Driver Installation Guide DGLC650C18PD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd/imh 250 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 50 250 V ow

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 90 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination APPLICATION The BAL3000 fluorescent emergency ballast works in conjunction with an AC

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled BASIC FX SR 50 W Combined emergency lighting LED Driver Product description Independent fixed output LED Driver for mains operation with integrated Simple CORRIDOR FUNCTION (CF) Emergency lighting function

More information

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108 Lighting Technology Compact Emergency Light Fittings Can be used in Zone 1 and Zone 2 With electronic ballast and integratal emergency light unit For continuous emergency operation 1 h or 1.5 h Operating

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 54 V SEV for

More information

High Efficiency Lighting units

High Efficiency Lighting units High Efficiency Lighting units Current Eligibility Criteria Various combinations of Lighting Fitting with Associated Control Gear and Lamp(s) meet the criteria for a High Efficiency lighting Unit. For

More information

Philips MASTER LEDtube InstantFit Standard Output 1500mm

Philips MASTER LEDtube InstantFit Standard Output 1500mm Philips MASTER LEDtube InstantFit Standard Output 1500mm The Philips MASTER LEDtube InstantFit is a technology breakthrough out of our LEDtube portfolio. This product is compatible with electronic ballasts

More information

Emergency lighting units EM series. EM BASIC, V BASIC version

Emergency lighting units EM series. EM BASIC, V BASIC version T T TCDE TCSE TCTE TC TCDD EM, 0 0 V version roduct description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps Small dimensions ( x mm crosssection) roperties

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

IQL Helios Area-/Streetlight. User Manual

IQL Helios Area-/Streetlight. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...

More information

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver

Emergency lighting units EM powerled. EM powerled BASIC 4W Emergency lighting LED Driver BASIC 4W Emergency lighting Driver Product description Emergency lighting Driver for manual testing For self-contained emergency lighting SEV for output voltage < 60 V DC ow profile casing (21 x 30 mm

More information

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires EdgeLED TM Range THIS FITTING SHOULD NOT BE USED IN AREAS EXCEEDING 25 C AMBIENT AIR TEMPERATURE This fitting must be installed by a qualified electrician and wired in accordance with the latest edition

More information

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks Project Type Model # Remarks Description: Firehorse Emergency Ballast for use with or without AC ballast designed to add emergency lighting when main AC power is interrupted for minimum of 90 minutes at

More information

Emergency lighting units EM INVERTER

Emergency lighting units EM INVERTER T T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM, 0 40 V 0/0 Hz PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent

More information

Induction lamps and control gear

Induction lamps and control gear Induction lamps and control gear The QL lamp systems are based on a unique physical principle of light generation: the QL induction technology. The QL induction technology is a breakthrough for professional

More information

LED Emergency Luminaires

LED Emergency Luminaires LED Emergency Luminaires THIS FITTING SHOULD NOT BE USED IN AREAS EXCEEDING 25 C AMBIENT AIR TEMPERATURE This fitting must be installed by a qualified electrician and wired in accordance with the latest

More information

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series EM converter EM converter BASIC 200 V BASIC series Product description lighting Driver for manual testing For modules with a forward voltage of 50 200 V ow profile casing (21 x 30 mm cross-section) For

More information

1000mA - 650mA Phase Dimmable LED Driver

1000mA - 650mA Phase Dimmable LED Driver Installation Guide DGLC1000C25PD 1000mA - 650mA Phase Dimmable LED Driver PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU

More information

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION EdgeLED TM Range THIS FITTING SHOULD NOT BE USED IN AREAS EXCEEDING 25 C AMBIENT AIR TEMPERATURE This fitting must be installed by a qualified electrician and wired in accordance with the latest edition

More information

Dialight LED Area Light. Technical Specification Sheet - CE

Dialight LED Area Light. Technical Specification Sheet - CE Dialight LED Area Light Technical Specification Sheet - CE Area Light Products Vigilant LED Area Light 100-277 VAC, 120-250 VDC Mechanical Information: Fixture weight: Adjustable bracket models Wall mount

More information

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series BASIC 90 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No Clean design lines give the Meridian range a leading edge for internal, easily maintained fittings. A straightforward design with a twist and lock diffuser means user-friendly maintenance and cost savings

More information

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type: APPLICATIONS LLMPS Series inverter systems are designed to provide sinusoidal AC emergency power to incandescent, flourescent, or LED fixtures of between 20 and 55 watts. Surface, recessed or ceiling T-Grid

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series BASIC 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile

More information

Dräger X-am 5100 Single-Gas Detection Device

Dräger X-am 5100 Single-Gas Detection Device Dräger X-am 5100 Single-Gas Detection Device For manufacturing petrochemical products, aseptic packing, or handling of rocket fuel: the Dräger X-am 5100 portable single-gas detector guarantees that you

More information

EMEX Power. EMEX Power. Modular AC/AC Central Battery System. EMEX Power

EMEX Power. EMEX Power. Modular AC/AC Central Battery System. EMEX Power EMEX Power EMEX Power Modular AC/AC Central Battery System EMEX Power EMEX Power Modular AC/AC Central Battery System System design The EMEX Power inverter and charger modules utilise solid state electronics

More information

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC T8 c PC BASIC sl, 4 28 W PC BASIC Product description CELMA Energy Efficiency Index A2 / A3 Nominal life-time up to 50,000 h (at max. ta with a failure rate max. 0.2 % per 1,000 h) Large temperature range

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22 ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components

More information

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC PC BASIC, 4 28 W PC BASIC Product description CELMA Energy Efficiency Index A2 / A3 Nominal life-time up to 50,000 h (at max. ta with a failure rate max. 0.2 % per 1,000 h) Large temperature range (for

More information

PROTECTA III. Construction Tough glass reinforced polyester body

PROTECTA III. Construction Tough glass reinforced polyester body PROTECTA III 20 Construction Tough glass reinforced polyester body Polycarbonate diffuser with high resistance to UV and stress cracking Robust hinges and multipoint compressive clamping of diffuser closure

More information

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany ECOLUX 6608 Series 6608/5 Explosion Protected Fluorescent Emergency Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled BASIC FX 80 W Combined emergency lighting LED Driver Product description Fixed-output LED Driver for mains operation with integrated Simple CORRIDOR FUNCTION (CF) Emergency lighting LED Driver with manual

More information

OVERVIEW. A compact, exterior, fully submersible discrete single LED luminaire delivering 100lm. IP67 SPEK. acdclighting.

OVERVIEW. A compact, exterior, fully submersible discrete single LED luminaire delivering 100lm. IP67 SPEK. acdclighting. acdclighting.com/led/ OVERVIEW A compact, exterior, fully submersible discrete single LED luminaire delivering 100lm. IP67 Compact size with excellent power utilising a single LED Available with clear

More information

Innovation in actuation.

Innovation in actuation. Innovation in actuation. Keystone EPI-2 Quarter Turn Electric Actuators Control your low-torque quarter turn valves and dampers more effectively, even in the largest plants. A world of experience Keystone

More information

Cast Resin Joints. Install and Forget

Cast Resin Joints. Install and Forget Install and Forget The new range of Rezi-Kon cast resin joints from Thomas & Betts provide a convenient and reliable solution for splicing and branching low voltage cables, in applications like street

More information

Linear fittings EVN Fluorescent fitting - zones 2 & 22

Linear fittings EVN Fluorescent fitting - zones 2 & 22 LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray

More information

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22 FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4

More information

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No Icebreaker is an ultra slim 2D luminaire at home in many IP44 applications. Ideally suited for bathrooms and utility areas, and most widely preferred in social and key worker housing and student accomodation.

More information

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008 Lighting Technology Emergency Light Fittings Can be used in Zone 1 and Zone 2 As pendant or pole-mounting fittings For single- and two-pin fluorescent lamps With electronic ballast and integral emergency

More information

ILED Aquarius Illuminated Windsock. User Manual

ILED Aquarius Illuminated Windsock. User Manual Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...

More information

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT Product description One-LED Solo TM is a non-maintained, self-contained LED emergency luminaire comprising an Omni-LED emergency LED driver, hinged rechargable battery and a flush-mount SELV lamp head.

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush

More information

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508 > Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5

More information

1 Mackwell Company Profile. 2 Emergency Lighting XYLUX XYVEX TEMPUS. 3 Emergency Monitoring System N-Light Connect N-Light EC

1 Mackwell Company Profile. 2 Emergency Lighting XYLUX XYVEX TEMPUS. 3 Emergency Monitoring System N-Light Connect N-Light EC product overview contents 1 Mackwell Company Profile 2 Emergency Lighting XYLUX XYVEX TEMPUS 3 Emergency Monitoring System N-Light Connect N-Light EC 4 Emergency Conversion Kits ELEDD MIDI 5 Emergency

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany , INC. ECOLUX 6600 Series 6600/5 Explosion Protected Fluorescent Light Fixtures for Hazardous and Corrosive Applications Please read this entire document before beginning any work. 1. Safety Instructions

More information

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Linear fittings Fluorescent fitting EVN - Zones 2 & 22 Fluorescent fitting Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable

More information

Emergency Lighting Control Gear

Emergency Lighting Control Gear Emergency 3W 6W Dual Wattage Emergency Driver Emergency ighting Control Gear SelfTest Version HEM06T / HEM07T Applications Emergency conversion units to provide constant power output in emergency mode.

More information

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44 Icebreaker is an ultra slim 2D luminaire at home in many IP44 applications. Ideally suited for bathrooms and utility areas, and most widely preferred in social and key worker housing and student accomodation.

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Emergency lighting Driver 1 W Product description Emergency lighting Driver for manual testing For self-contained emergency lighting on maintained operation SEV for output voltage < 60 V DC

More information

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety 4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Emergency lighting units Product description emergency lighting supply unit with I interface and automatic test function Properties Mains and emergency operation I interface

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Emergency lighting Driver 1 W Product description Emergency lighting Driver for manual testing For self-contained emergency lighting on maintained operation SEV for output voltage < 60 V DC

More information

Beam lights & conversion kits

Beam lights & conversion kits .0 Overview... 81.1 Planete 2000... 82.2 Beamlite... 83.3 Gemini Junior... 84.4 EL40... 8. Conversion Kit... 86 Emergency lighting design handbook revision 4 dh_el_rev.4_eng July 2014 79 80 Emergency lighting

More information

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps Reliability with the most essential intellect Philips HF-Essential Electronic ballasts for TL5 lamps HF-Essential - Reliability with the most essential intellect Electronic ballasts for TL5 lamps The cost-saving

More information

Orchard Residences. Buckley 18 IM Flash

Orchard Residences. Buckley 18 IM Flash EMTECH BS4568 / IEC61386 CLASS 3 CONDUIT PIPE EMTECH TM GI Conduit BS4568 / IEC61386 Class 3 EMTECH TM EMT-3 Conduit Box ITE West Marina Barrage Orchard Residences Buckley 18 IM Flash data listed in this

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power BASIC 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing For self-contained emergency lighting SEV for output voltage < 60

More information

ULTIMA Ni-Cd BATTERY: PEAK PERFORMANCE WITH ULTRA LOW MAINTENANCE

ULTIMA Ni-Cd BATTERY: PEAK PERFORMANCE WITH ULTRA LOW MAINTENANCE ULTIMA Ni-Cd BATTERY: PEAK PERFORMANCE WITH ULTRA LOW MAINTENANCE ULTRA LOW MAINTENANCE Ni-Cd FOR WHEN SAFETY CANNOT BE COMPROMISED Developed in line with long proven nickel-cadmium technology, the Ultima

More information

OVERVIEW. A compact, exterior, fully submersible discrete single LED luminaire delivering 100lm. IP68 SPEK. acdclighting.

OVERVIEW. A compact, exterior, fully submersible discrete single LED luminaire delivering 100lm. IP68 SPEK. acdclighting. acdclighting.com/led/ OVERVIEW A compact, exterior, fully submersible discrete single LED luminaire delivering 100lm. IP68 Compact size with excellent power utilising a single LED Available with clear

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps Product description oise-free precise control via signal or switchdim CELMA energy class A1 1) Interfaces switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer setting Automatically

More information

KLED18STD. Product Overview. 18w LED DD Standard, 30000hrs

KLED18STD. Product Overview. 18w LED DD Standard, 30000hrs KLED18STD 18w LED DD Standard, 30000hrs Product Overview Kosnic s range of LED DD lamps takes a fresh approach to functional lighting with a design philosophy offering plug-in emergency packs and optional

More information

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22 Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation

More information

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications LIEAR FITTIGS - EVT FLUORESCET FITTIG - IDUSTRIAL APPLICATIOS 95 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access

More information

Reliant luminaires. Edge-lit exit sign available in 3 Colours. 40% Energy saving. 4 Years maintenance free. Easy first-fix installation

Reliant luminaires. Edge-lit exit sign available in 3 Colours. 40% Energy saving. 4 Years maintenance free. Easy first-fix installation Reliant luminaires With 40% energy saving through cold cathode technology and 4 years maintenance free, Reliant luminaires offer incomparable benefits to the lighting designer. Easy first-fix installation

More information

PRODUCT GUIDE MAKING SMART SOLUTIONS SIMPLE

PRODUCT GUIDE MAKING SMART SOLUTIONS SIMPLE PRODUCT GUIDE MAKING SMART SOLUTIONS SIMPLE CONTENTS EMERGENCY 3 ONE-LED OMNI-LED 4-5 OMNI-LED DST 6-7 UNITY-LED 8-9 SOLO 10-11 SOLUTIONS 13 ONE-LED SOLUTIONS OMNI-LED FLEXI 14-15 OMNI-LED FLEXI 230V 16-17

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information