1 operation instruction AKKUTEC 2403 NBPA 2403-Q33G1 and NBPR 2403-Q33G1 with battery sensor MTIA Q33G3M01 and battery module NBBH - Q33G1M01 device designation notes art..no. nominal input nominal output voltage voltage AKKUTEC standard unit, module NBPAQ33G1M01 230V AC 24V DC AKKUTEC standard unit, 19 Akku 7,2 NBPRQ33G1M03 230V AC 24V DC AKKUTEC Ah / 12 Ah terminals on NBPRQ33G1M04 the rear side 1/10 Technical modificastions possible!

2 Safety regulations The operational instructions must be read and followed before the use respectively the installation of the device! In case of non-observance guarantee and warrenty claims are no longer valid! The assembly, start-up and maintenance may be done by trained personnel only. The valid VDE-regulations, especially DIN VDE 0100 and EN are to be respected!! The protective conductor must be connected (protective class I) Incoming and outgoing feeders must dimensioned and fused sufficiently (values see chapter 3.1)! For the release of the power supply for the mains and the battery circuit a separation unit must be foreseen. The unit is a mount-in device. The operation is only permissible in dry rooms. The allowed environmental temperature range is to respected! Only the battery types specified for the unit are permitted to be used! Battery replacement is only to be made with the unit unpowered! On the connection of external backup batteries, battery protection must be provided by the user! In this case the protection components (overload and short circuit protection!) must be installed as close as possible to the set of batteries for safety reasons! On the usage of batteries, sufficient air flow in accordance with VDE 0510, part 2 must be ensured Never connect together new and used batteries, or batteries of different types, or from different manufacturers! The unit may only be opened by qualified personnel. In case of failure we recommend to send the unit back to the manufacturer The disregard of the safety regulations may cause perilous injuries. In case of exceeding the values given in the technical Data, the risk of damage of the unit occurs. 1. Concise Description The battery backed up DC power supply in the AKKUTEC range uses the standby-parallel principle of operation and, in conjunction with a lead accumulator, ensures that the DC powe r supply is reliably maintained in the case of a mains power failure. The back-up time depends on the state of charge of the batteries and of the discharge current. The power supply has the following features: battery charger system with I/U charging cha racteristic Microcontroller-based battery management Temperature compensation for charging voltage by means of external sensor module (optional module) 2. Norms and Regulations power- HF- transducer to ensure safe separation of primary and secondary Opto couplers for protective separation against electric shock, requirements - tests EMV interference resistance: EN EN (VDE ) VDE 0884 EN und EN Klasse A EN Klasse B EN (static discharge ESD) (4kV) EN (electromagnetic fields) (10V/m) EN (fast transients / Burst) input (2kV) output (1kV) EN (Surge) mains (2 / 4kV) output(0,5kv) EN (conducted stability) 10V, 150kHz 80MHz EN (voltage breaks) back-up with battery Overall unit EN / EN /10 Technical modificastions possible!

3 3.1. Technical Data nominal input voltage 230V AC max. power loss input voltage range 197,75-264,5V 230V 15% - 230V + 15% worst-case earth leackage current 12W <3,5mA NBPAQ33G1D input frequency 47-63Hz fusing input 250V 2A T H (internal) nominal input current 0,7 A fusing 3A T (external) DC- output circuit max. inrush current 30A / 2ms fusing 3A T (external) battery circuit output voltage ( without battery ) output voltage ( with battery ) 26,8V DC ±0,4% 19,8V 26,8V DC±0,4% tpye of connection input mains Federzug max. 1,5mm² final charging voltage 26,8V DC ±0,4% without temp.-sensor type of connection output Ua, Batt Federzug max. 1,5mm² 27V at 25 C (temp.-sensor optional) with temp.-sensor charging characteristics I/U DIN type of connections Federzug max. 1mm² messages deep discharge protection 19,8V DC ±0,4% protective system IP 20 a. EN and load rejection at nominal output current 2,85A DC weight mounting version 0,55kg 19 version with batt. 7,0kg (7,2Ah) 9,6kg (12Ah) constant current limitation 1,05...1,1 x I ANom storage temperature C battey type Pb-battery, maintenance environmental 0-45 C free temperature 0-25 C recommended for battery efficiency Ua=26,8V DC, Ia= I Anom and Ue=230V AC 3.2 Displays and Message Outputs mains OK 1) battery OK 1) battery low 87% dimensions 92,5 x 60 x 116mm (h x w x d) LED green, illuminates at: mains operations, means : UE>U Emin LED green, expires at disconnection of battery circuit battery voltage < 21,6 V ( battery operation ) battery damaged battery temperature > 45 C LED green, is blinking 1) The message contacts are connected with LED-displays. In case of illuminated LED the corresponding relay is energized. potential-free relay-contact, changer, max. contact load 30V DC/ 0,5A potential-free relay-contact, closer, max. contact load 30V DC/ 0,5A 3.3 Message inputs Shut-Down shut-down of the UPS- operation switched input referring to earth, switching level: 24V DC (6-45 V DC) 3/10 Technical modificastions possible!

4 4. Installation The battery backed up DC power supply is to be installed such that the necessary cooling is provided. A minimum separation of 40mm to neighbouring equipment or assemblies in the area of the v entilation openings is to be maintained. The installation is always to be made in such a way that sufficient air circulation through the unit is ensured. The temperature of the cooling air at the bottom of the unit may not exceed the value given in the tec hnical data. The maximum mounting heights without load reduction is about 1000 m above N.N. During installation, the unit is to be covered in the case that swarfs from drilling can fall on or in the unit. ( Risk of short circuit!) 5. Cconnection Prior to connection, the values for the mains voltage and frequency as well as the values of the battery are to be checked against the values on the rating plate. Connect in accordance with the labels on the connecting terminals. (See main block diagram an d connector assignments). Unused connecting terminal screws are to be tightened. connection: terminal: connection: terminal: mains input terminal connection Netz L, N, PE control input shut-cown terminal connection IO / 4 - DC-output (load) terminal connection Ua +, - mains OK mains present mains interruption IO-1 6 / 7 (closed) 5 / 7 (closed) Pb-battery terminal connection batt OK 8 / 9 (closed) battery- temperature sensor (optional module) Batt +, - terminal connection IO- 1 1, 2 In the case of overload, the DC output current comprises the maximum charging rectifier current as well as the current from the battery. To prevent overload of the DC output circuit, the circuit is to be protected externally! (Value see Section 3.1) 6. Circuit diagramm Netz Ubatt I / O Ua + _ AKKUTEC /10 Technical modificastions possible!

5 7. Putting into operation The unit is switched on by the application of the mains supply. If the units are built-in into systems, for which overvoltages for testing are required (for example according EN / VDE0113 part voltage examination), the unit must be separated from the test assembly before switching on the voltage. (Original text EN : parts, which are not dimensioned for this testing voltages must be disconnected during the testing.) The battery voltage must match the nominal voltage of the charging rectifier! Never reverse the poles of the battery! Never short circuit batteries! Risk of arcing! Check the connections for correctness prior to switching on for the first time Only make electrical connections with the unit unpowered 8. Operation Approx. 2s after the switch on of the mains, the output voltage is released and the loads which are connected are supplied with power. The back up battery is also charged. This operating mode is indicated by the illumination of the green Netzbetr ieb (Mains Operation) LED. By removing the mains voltage, or if the input voltage drops below the minimum, the AKKUTEC switches over to battery mode. The Netzbetrieb (Mains Operation) LED is not illuminated in this case. The illumination of an LED always results in the energisation of the corresponding signal relay. (See block diagram, point 6) 9.1 Battery Circuit Control To check the capability of the UPS to provide back up, the battery circuit is tested cyclically at intervals of 60s; the first test is performed 60s after mains switch on. By means of this test it is possible to identify an open circuit or the high resistivity of the battery circuit. A defective battery circuit is indicated by the expiry of the Batt ok LED 9.2 Battery Test During mains operation, a cyclic battery test loads the battery whilst the voltage is measured. In this way it is possible to evaluate the quality of the battery. A seriously aged battery is indicated by the expiry of the LED Batt. OK. About one ho ur of switching on the mains the first battery test is effected, each other after 24 hours. F With the help of the processor controlled automatic battery test the back-up capability of the battery is ensured. To give a detailed declaration concerning the capacity of the batteries in the system, we recommend additionally the control of the batteries with the nominal load current at least once a year. For this battery operation must be enforced by mains disconnection and to verify the back-up time until the self shut-down because of the discharge protection. The real battery capacity can be calculated with the back-up time and the nominal load. If the capacity of the batteries for the necessary back-up time is not sufficient the batteries must be changed. 9.3 Shut-Down To avoid the discharge of the backup batteries to the deep discharge limit unnecessarily, it is possible to shut down battery operation earlier. This is performed by applying a +24V DC control voltage to connection 3 (+) and 4 (-) on the IO-1 terminal strip. 5/10 Technical modificastions possible!

6 9.4 Temperature Compensation (optional module) Lead batteries have a temperature coefficient of approx. -3mV per C and cell. The AKKUTEC final charging voltage is selected such that battery charging is provided over a temperature range of C. In applications with frequent and large temperature variations, the charging voltage should be appropriately compensated to achieve optimal battery life. Also, particularly in the case of very low surrounding air temperature (Tu < 15 C), compensation should be performed to ensure adequate battery charging. By connecting the external temperature sensor module (option) to terminal strip IO-1 connection 1 and 2 (note poles!), temperature compensation is automatically activated. For an surrounding air temperature variation of 0-45 C, the final charging voltage (and thus also the output voltage) varies over a range of V DC Battery temperatures above 45 C are indicated by the expiry of the LED Batt ok. F To obtain satisfactory battery life, the operating temperature of the batteries should not exceed 20 C. Higher temperatures lead to a drastic reduction in the life! 10. Taking out of operation The unit is taken out of operation by removing the mains supply. To prevent subsequent backup from the batteries, the battery circuit must be opened by activating Shut-Down. (See point 9.3) The LED s Netz ok (Mains Operation) and Batt ok must expire. Never undo electrical connections whilst the unit is in operation! It also not permitted to make electrical connections whilst the unit is in operation 11. Installation drawings snap fixation for 35 mm Norm profil tracks DIN EN x 15/7,5 Netz AKKUTEC PE L N I/O Netz OK Batt OK 92.5 Batt Ua J. Schneider Elektrotechnik GmbH 60 Tiefe 116mm inkl. Klemmen depth 116mm incl. terminal 6/10 Technical modificastions possible!

7 mounting depth without terminals! NBPAQ33G1D Einbautiefe Mounting depth : 244mm (ohne Griffe) : 244mm (without grips) 12. Maintenance Within the unit there are no parts which may be maintained by the user. The unit must be cleaned regularly, depending on the degree of soiling The batteries must be checked as described in chapter 9.2 and must eventually be replaced. 7/10 Technical modificastions possible!

8 Optional module Operational instruction battery module NBBH 2401 Article No.: NBBHQ33G1M01 Tiefe 103mm depht 103mm battery type: maintenance-free lead batteries 24V / 1 Ah battery fusing: 3 A FK2 back-up time: 30 min at 2 A load dimensions in mm: ( width x height x depth) : 69 x 120 x 103mm assembly: on 35 mm norm profile tracks DIN EN x 15/7,5 assembly: by fastening lashes look at drawing 8/10 Technical modificastions possible!

9 Optional module NBPAQ33G1D operational instruction temperature sensor AKKUTEC 2403 MTIA Q33G3M01 Safety regulations The operational instructions must be read and followed before the use respectively the installation of the device! In case of non-observance guarantee and warranty claims are no longer valid! The assembly, start-up and maintenance may be done by trained personnel only. The unit is a mount-in device. The operation is only permissible in dry rooms (IP 20). The allowed environmental temperature range is to respected! The connection and disconnection of electrical connection may only be realized in un-energized state. The unit may only be opened by qualified personnel. In case of failure we recommend to send the unit back to the manufacturer Concise description Lead batteries have a temperature coefficient of approx. -3mV per C and cell. The final charging voltage is selected such that battery charging is provided over a temperature range of C. In applications with frequent and large temperature variations, the charging voltage should be appropriately compensated to avoid a battery over charging (danger of gas). Also, particularly in the case of very low surrounding air temperature (Tu < 15 C), compensation should be performed to ensure adequate battery charging. By connecting the external temperature sensor module (option) to terminal strip IO-1 connection 1 and 2 (note poles!), temperature compensation is automatically activated. For an environmental air temperature variation of 0-45 C, the final charging voltage (and thus also the output voltage) varies over a range of V DC Battery temperatures above 45 C are indicated by the expiry of the LED Batt ok. Scope of delivery temperature sensor with 1m connection cable 0,5 mm² Nylon-cable clamp with 4,3 mm² drill hole 9/10 Technical modificastions possible!

10 Installation The battery sensor should be installed near the battery as shown in the example of the battery module NBBH 2402 (see picture). In this way the accurate measurement of the environmental temperature of the battery is granted.. Connection The temperature sensor is connected at the terminal IO-1 connection 1 and 2 of the AKKUTEC The polarity of the connection cable is free. A maximum length of the cable of 3 m is to be observed. The width of the cable should amount to 0,5 mm 2. Start-up operation The temperature sensor is recognized automatically from the AKKUTEC after the mains is switched on and the charching voltage is compensated depending on the temperature. An additional parameter or the switch on by a seperate switch at the unit is not necessary. 10/10 Technical modificastions possible!

Operation Instructions

Operation Instructions Operation Instructions AKKUTEC 2405 USB NBPA0616G01 device designation notes art.no. nominal input voltage nominal output voltage AKKUTEC 2405-0 USB standard device, single module NBPA0616G01001 115-230V

More information

DC-UPS INTRODUCTION SOME OF THE MANY APPLICATIONS:

DC-UPS INTRODUCTION SOME OF THE MANY APPLICATIONS: Since 984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing

More information

Industrial Power Supplies

Industrial Power Supplies , Features Switch Mode Power Supplies for DIN-rail Mounting 6 Power Ranges with 2, 3, 6, 12, 20 and 24 A Current (24 VDC Models) Selectable 115/ 230 VAC Input Very low Ripple and Noise EMI complies with

More information

Operating manual UPS - System

Operating manual UPS - System Operating manual UPS - System POWERMASTER M MIL 1000VA 7Min. BAX 3330 E UPS-Division Issued 15. August 2006 JOVYATLAS JOVYATLAS Elektrische Umformtechnik GmbH Groninger Straße 29-37 D-26789 Leer/Ostfriesland

More information

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7 EBL 208, Art.-No 911.430 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W Page 1 / 7 Full operation without need of battery Two independent 48Vdc outputs for switching and control Local monitoring with 8 LEDs Remote monitoring with 4 alarm relays Monitoring and configuration

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing (21 x 30 mm cross-section)

More information

QUINT-PS/24DC/24DC/20

QUINT-PS/24DC/24DC/20 DC/DC converter with SFB Technology, primaryswitched, input: 24 V DC, output: 24 V DC, output current: 20 A Data sheet 104791_en_01 PHOENIX CONTACT 20130405 1 Description QUINT DC/DC converter maximum

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 90 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

QUINT-PS/24DC/24DC/10

QUINT-PS/24DC/24DC/10 DC/DC converter with SFB Technology, primaryswitched, input: 24 V DC, output: 24 V DC, output current: 10 A Data sheet 104790_en_01 PHOENIX CONTACT 20130405 1 Description QUINT DC/DC converter maximum

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J. EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4

More information

MINI MCR-SL-UI-UI(-SP)(-NC)

MINI MCR-SL-UI-UI(-SP)(-NC) Configurable 3-Way Isolating Amplifier Data Sheet 04/2005 Functions Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP)(-NC) is used to electrically isolate, condition, amplify,

More information

QUINT-PS/24DC/48DC/ 5

QUINT-PS/24DC/48DC/ 5 DC/DC converter with SFB technology, primaryswitched, input: 24 V DC, output: 48 V DC, output current: 5 A Data sheet 104793_en_01 PHOENIX CONTACT 20130503 1 Description QUINT DC/DC converter maximum system

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A) A Complete solution for small battery-backed dc instrument power systems. DATASHEET Supply 12Vdc 8A or 24Vdc 6A loads Ideal for RTU s, dataloggers, remote field instrumentation, alarm systems, etc. where

More information

MINI MCR-SL-UI-UI(-SP)

MINI MCR-SL-UI-UI(-SP) Configurable 3-Way Isolating Amplifier Data Sheet 11/2004 Product Description Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP) is used to electrically isolate, condition, amplify,

More information

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) LINEAR LED DRIVERS ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL) 186443, 186444, 186486, 186487, 186488, 186491, 186492, 186737 Typical Applications Built-in in linear luminaires for Office lighting

More information

QUINT-PS/24DC/24DC/ 5/CO

QUINT-PS/24DC/24DC/ 5/CO DC/DC converter with SFB technology, dip-coated, primary-switched, input: 24 V DC, output: 24 V DC, output current: 5 A Data sheet 105537_en_01 PHOENIX CONTACT 2014-02-13 1 Description QUT DC/DC converter

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled BASIC FX 80 W Combined emergency lighting LED Driver Product description Fixed-output LED Driver for mains operation with integrated Simple CORRIDOR FUNCTION (CF) Emergency lighting LED Driver with manual

More information

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series EM converter EM converter BASIC 200 V BASIC series Product description lighting Driver for manual testing For modules with a forward voltage of 50 200 V ow profile casing (21 x 30 mm cross-section) For

More information

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A Data sheet 105541_en_00 PHOENIX CONTACT 20130503 1 Description QUT DC/DC converter maximum system

More information

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series BASIC 90 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd/imh 250 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 50 250 V ow

More information

Power Supply EL

Power Supply EL General information: EL630-1203-7 has been specifically developed to meet the DC powering requirements for telecommunications, industrial and marine applications. The output is current limited, with short

More information

GV-10 Manual 10.5A / 140W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

GV-10 Manual 10.5A / 140W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking GV-10 Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GV-10-Pb-12V: GV-10-Pb-CV: 12V Lead-Acid/AGM/Gel/Sealed/Flooded 12V Custom Multi-Stage Lead-Acid/AGM/Gel/ Sealed/Flooded

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 54 V SEV for

More information

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series BASIC 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile

More information

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES ADDITIONAL EMERGENCY POWER SUPPLY DEVICES ADDITIONAL EMERGENCY POWER SUPPLY DEVICES OP Emergency power supplies according to VDE 0107 ZSV installations according to VDE 0107 AREAS OF USE Hospitals Out-patient

More information

LV Capacitor CLMD03 Power Module Instruction manual

LV Capacitor CLMD03 Power Module Instruction manual LV Capacitor CLMD03 Power Module Instruction manual Table of Contents 1 Safety... 3 2 Upon reception... 3 2.1 Inspection on reception... 3 2.2 Storage- transportation handling... 3 3 Hardware Description...

More information

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7 EBL 99 C, Art.-Nr. 911.413 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

QUINT-PS/24DC/24DC/10/CO

QUINT-PS/24DC/24DC/10/CO DC/DC converter with SFB technology, dipcoated, primaryswitched, input: 24 V DC, output: 24 V DC, output current: 10 A Data sheet 105538_en_01 PHOENIX CONTACT 20140213 1 Description QUT DC/DC converter

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Electrical network protection VIP30, VIP35. User s manual 12/2008

Electrical network protection VIP30, VIP35. User s manual 12/2008 Electrical network protection VIP30, VIP35 User s manual 1/008 Safety instructions ANSI symbol. IEC symbol. Safety symbols and messages Read these instructions carefully and look at the equipment to become

More information

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10 our name is our principle UV- TECHNOLOGY Technical Documentation ELC N6 / ELC N8 / ELC N10 GB eta plus electronic gmbh Lauterstraße 29, D-72622 Nürtingen, Telefon +49 (0) 70 22-60 02-80, Fax +49 (0) 70

More information

CHARGING UNIT DEM 313

CHARGING UNIT DEM 313 OWNER S MANUAL CHARGING UNIT DEM 313 Features fully automatic charging unit 24V/4A for constant I/U battery charging in continuous battery power supply mode regulation of charging voltage with high-efficiency

More information

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/24DC/2 Order No.: 2866640 Uninterruptible power supply with integrated power supply unit, 2 A, in combination with MINI-BAT/24/DC 0.8 AH or 1.3 AH Commercial

More information

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series Driver LC 150W 200 1050mA IND sl EXC EXCITE series Product description Constant current built-in Driver for LED, particularly suitable for industrial applications in tough environments such as cold warehouses

More information

DC/DC converters - MINI-PS DC/ 5-15DC/

DC/DC converters - MINI-PS DC/ 5-15DC/ Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

Fuse state indicator MEg72. User manual

Fuse state indicator MEg72. User manual Fuse state indicator MEg72 User manual MEg Měřící Energetické paráty, a.s. 664 31 Česká 390 Czech Republic Fuse state indicator MEg72 User manual Fuse state indicator MEg72 INTRODUCTION The fuse state

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S Product Manual ABB i-bus EIB EIB Power Supply Units SV/S 30.320.5 SV/S 30.640.5 SU/S 30.640. Intelligent Installation Systems Contents Page EIB Power Supply Units. Introduction.........................................

More information

Power Supply EL

Power Supply EL General information: EL610-2412-24 with dual outputs has been specifically developed to meet the DC powering requirements for telecommunications, industrial and marine applications. The unit has a 230Vac,

More information

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information Segment Terminal Fused, with Diagnostics 24VDC Segment Terminal module is used to create a protected partial circuit (segment circuit) within the main circuit. It is not used to supply power and has no

More information

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking. GV-4 Manual Solar Charge Controller with Maximum Power Point Tracking For models: GV-4-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded http://genasun.com Genasun Inc. 1035 Cambridge st. Suite 16B Cambridge,

More information

BODAS Pressure sensor PR3 series 10

BODAS Pressure sensor PR3 series 10 BODAS Pressure sensor PR3 series 10 RE 95155 Edition: 04.2014 Replaces: 12.2013 Measurement ranges to 25, 50, 160, 200, 250, 400, 600 bar Ratiometric output signal 0.5 to 4.5 V with 5 V supply voltage

More information

Uninterruptible power supplies (UPS)

Uninterruptible power supplies (UPS) Contents Overview.2 UPS control unit.4 attery modules.6 uffer modules.8 1460790000 2014/2015.1 Overview Uninterruptible power supplies Weidmüller s uninterruptible power supplies reliably protect 24 V

More information

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal) 86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013

More information

Protection and control VIP30, VIP35. Relays technical manual

Protection and control VIP30, VIP35. Relays technical manual Protection and control VIP30, VIP35 Relays technical manual contents 1. presentation of the VIP30 and VIP35...3 2. use and settings...4 3. sensors and operating ranges... 4. connection scheme...9 5. assembly

More information

Angle sensor AN2 series 30

Angle sensor AN2 series 30 Angle sensor AN2 series 30 RE 95143 Edition: 09.2016 Replaces: 06.2015 Hall-effect sensor for angular measurement Features Angle sensor element based on the Hall-effect principle Shaft can be turned through

More information

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS Introduction ST - II Series POWER SUPPLIES These instructions detail the installation and operation requirements for the ST20-II & ST35-II power supplies. These have been designed for operation in RV s

More information

Electronic Ballast EVG 2000-T

Electronic Ballast EVG 2000-T Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications

More information

Features. Description. Table of Contents

Features. Description. Table of Contents Features Very low profile Very high efficiency (typically 90%) Single and dual output versions Input voltages from 24V to 110VDC nominal voltages from 5V to 48VDC -40 C to +71 C operation without de-rating

More information

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets 86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module

More information

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES Switching Power Supply S82F Industrial-Grade Power Supply for General or Peak Load Applications Correct input voltage range is automatically selected: 1 VAC or 2 VAC. Model S82F-P is suitable for peak

More information

LIGHTNING PROTECTION UNIT (LPU)

LIGHTNING PROTECTION UNIT (LPU) LIGHTNING PROTECTION UNIT (LPU) Photovoltaic Lightning Protection Device Installation and Operation Manual SPECIALTY CONCEPTS, INC. 8954 Mason Ave. Chatsworth, CA 91311 USA MODELS COVERED: LPU-50, LPU-150,

More information

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , , ROBUST LED DRIVERS EasyLine INDUSTRY 186452, 186453, 186454, 186455, 186456, 186477, 186510, 186617 Typical Applications Built-in in compact luminaires for Industrial lighting EasyLine Industry ENCAPSULATED

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements. Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 45W 500 1400mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 25W 350 1050mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Technical data. Miniature Circuit Breakers. System pro M. System pro M Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series Product description Fixed output constant current built-in LED Driver, particularly suitable for industrial applications in tough enviromments such

More information

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series PRO 50 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output

More information

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Power Electronics. MINISTOP Motor Brake Relay BA 9034N Power Electronics IISTOP otor Brake Relay BA 9034 0256981 Your advantages Higher safety level and more economic by short stopping cycle Cost saving Compact design Easily appliance, no need for current

More information

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC Inline Power Terminal With Fuse and Diagnostics Data Sheet 5569C 02/2003 # # $ ' ) The IB IL 24 PWR IN/F-D and IB IL 24 PWR IN/F-D-PAC only differ in the scope

More information

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series Product description Fixed output constant current built-in LED Driver, particularly suitable for industrial applications in tough enviromments such

More information

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.

More information

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC stage to convert the 3-phase input

More information

MODVAR Low voltage reactive power compensation modules Installation manual

MODVAR Low voltage reactive power compensation modules Installation manual MODVAR Low voltage reactive power compensation modules Installation manual MODVAR Low voltage reactive power compensation modules Before installation, read this manual carefully and keep at the disposal

More information

Operating instructions Flow monitors SI / / 2010

Operating instructions Flow monitors SI / / 2010 Operating instructions Flow monitors SI5004 UK 704339 / 02 08 / 2010 Contents 1 Safety instructions 3 2 Functions and features 4 2.1 Application area 4 2.2 Operating principle flow monitoring 4 3 Installation

More information

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011 Operating instructions Flow monitors SI6000 SI6100 SI6200 706053/00 06/2011 Contents 1 Safety instructions... 3 2 Functions and features... 4 2.1 Application area... 4 2.2 Operating principle flow monitoring...

More information

8. Filter / Autoranging Rectifier Module (FARM )

8. Filter / Autoranging Rectifier Module (FARM ) Maxi, Mini, Micro Family DC-DC s and Configurable Power Supplies The Filter / Autoranging Rectifier Module (FARM provides an effective solution for the AC front end of a power supply built with converters.

More information

Safety technique. Emergency Stop Module BH 5928, BI 5928

Safety technique. Emergency Stop Module BH 5928, BI 5928 Safety technique Emergency Stop Module BH 5928, BI 5928 with time delay safemaster 0226419 Function diagram According to EU directive for machines 98/37/EG According to IEC/E 60 204, E 954-1 Safety category

More information

GVB-8 (Boost) Manual

GVB-8 (Boost) Manual GVB-8 (Boost) Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GVB-8-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded GVB-8-Pb-24V: GVB-8-Pb-36V: GVB-8-Pb-48V: GVB-8-Pb-CV: 24V

More information

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T. ALIEM USER MANUAL 2 19-04-2018 R. Bocconi REV. DATE Checked and Approved R. T. PAGE INTENTIONALLY LEFT BLANK 2 ALIEM 1000 USER'S MANUAL Version 2 dated 19-04-2018 1 INTRODUCTION ALIEM 1000 is an emergency

More information

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011 Operating instructions Flow monitors SI6600 SI6700 SI6800 UK 704680/02 01/2011 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 3 3 Functions and features 4 3.1 Application

More information

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC stage to convert the 3-phase input

More information

Motor Starter Reverse MSR22-FBP

Motor Starter Reverse MSR22-FBP Technical Description FBP FieldBusPlug V6 Motor Starter Reverse MSR22-FBP V 6 MSR22-FBPMotor Starter Reverse MSR22-FBP: Motor branch connection 1 motor, 2 directions of rotation Connecting plug for external

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE Operating instructions FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE 1547440000 IE-CL240W-PP-REMOTE 1547450000 Technical service: freecon.contactless@weidmueller.com Weidmüller

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power SEFTEST 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with self-test function For self-contained emergency lighting SEV for output voltage

More information

Local Control Network - building controls in perfection

Local Control Network - building controls in perfection 2 1 F3,15A250V 2 1 1 2 F3,15A250V Installation guide Local Control Network - building controls in perfection Sensor/actuator module for DIN-rail mounting The is a sensor/actuator module for building installation

More information

Operating Instruction Electric Quick-Closing Valve Systems

Operating Instruction Electric Quick-Closing Valve Systems Contents 1. General... 1 1.1. Marks... 1 1.2. Tightness of Quick-Closing Valves... 2 1.3. Medium... 2 1.4. Ambient and Medium Temperature... 2 1.5. Vibrations... 2 1.6. Pipe Tensions... 2 1.7. Protection

More information

24V 3A EN54 Ancillary Power Supply

24V 3A EN54 Ancillary Power Supply 24V 3A EN54 Ancillary Power Supply Normal supply - green light on Fault condition - call Engineer Control relay - activated 3A Power Supply C-TEC Manufactured in England by C-Tec EN 54-4 : 1997 INSTALLATION

More information

INTRODUCTION. Specifications. Operating voltage range:

INTRODUCTION. Specifications. Operating voltage range: INTRODUCTION INTRODUCTION Thank you for purchasing the EcoPower Electron 65 AC Charger. This product is a fast charger with a high performance microprocessor and specialized operating software. Please

More information

Charging of HOPPECKE OPzV solar.power battery in Solar Applications

Charging of HOPPECKE OPzV solar.power battery in Solar Applications Charging of HOPPECKE OPzV solar.power battery in Solar Applications Preface: This document provides hints for charging of HOPPECKE OPzV solar.power battery cells and blocs in solar applications. Note:

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies Data sheet Redundancy unit -A-RU Accessory for range power supplies ABB s redundancy units are used to establish true redundancy which increases the availability of electrical systems significantly. 2CDC

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information