1 Operating manual (translation of the original operating manual) Date: 03/2007 Dear Customer, thank you for purchasing our hoist. You have acquired a functional hoist with simple handling and the highest safety standard. Please always keep this manual in the vicinity of the hoist. made in troisdorf

2 TABLE OF CONTENTS 1 Introduction 3 2 Intended purpose, application area 3 3 General safety instructions 4 4 Receipt 5 5 Scope of delivery 5 6 Overview aks goliath 6 7 Commissioning 7 8 Operation Parking brake Manual control unit Spreading EMERGENCY STOP button Emergency lowering Wall charging station Rechargeable battery 13 9 Patient sling Accessories / combination Care / cleaning Storage Reuse Warranty Disposal Maintenance Service life Maintenance schedule Technical data Declaration of conformity 22 Page 2 GA_Lifter_goliath_070302_EN

3 1 Introduction Mobility, independence and increased quality of life as a result as well as a high degree of safety are certainly also your requirements. The aks goliath heavy-duty hoist meets these requirements. The mature technology and the convenient configuration ensure safe use. This means more quality of life for the patient and making the work easier for the care personnel. Among other things, the aks goliath is distinguished by the following features: stable construction with plug-in mast removable rechargeable battery pack with separate wall charging station high quality double castors with diameter of 100 mm (2 of these with parking brakes) electrically operated spreading of the chassis Read and observe this operating manual before first use. The present operating manual gives you the necessary information for safe use. In the case of a change of owner, pass on this operating manual. 2 Intended purpose / application area The heavy-duty hoist is intended for short-time use and can be universally used for the complete field of nursing care. The heavy-duty hoist described here is used exclusively for the conveyance / transfer of a single person up to maximum 150 kg in a sling. The heavy-duty hoist is not suitable for transporting over long distances or into other building levels. It is also not designed for misuse as a means of transport for objects. The climatic conditions should be an ambient temperature from +5 C to +40 C, relative humidity from 20% to 90% and air pressure from 700 hpa to 1060 hpa. Page 3

4 3 General safety instructions The operating manual for the aks heavy-duty hoist and the accessories used must be read carefully and completely before start-up to prevent damage due to incorrect operation or hazards. It contains important information and instructions which are necessary for the proper operation of the aks heavy-duty hoist. The aks heavy-duty hoist must only be used by persons who have read and understood the operating manual and have been informed about risks and safety precautions. The user must have been instructed about handling the aks heavy duty hoist. The user must ensure the proper, faultless condition of the aks heavy-duty hoist before every use. It must particularly be ensured that the aks heavy-duty hoist has been mounted in accordance with the operating manual and that it does not show any damage. All parts of the aks heavy-duty hoist and accessories must be attached safely and correctly. Boom and sling must be selected in accordance with the task in relation to model, size and design. Ensure that the sling system has been correctly and securely applied to the patient so that the patient is not injured during lifting. Never leave the patient unsupervised in the sling system. Not even for a short time. This particularly applies if there are persons in the vicinity who have not been instructed in handling the aks heavy-duty hoist (e.g. other patients, children etc.). In certain cases, electrical equipment can be affected by switched on cordless and mobile telephones and WLAN, Bluetooth or other equipment emitting radio waves. These can impair the function of the heavy-duty hoist. Particular caution is also required for strong electrical interference sources. The activation time and the safe working load must not be exceeded, otherwise safe operation can no longer be guaranteed. Ensure that no moisture penetrates into the electrical system. In the event of damage or malfunction, the aks heavy-duty hoist must not continue to be operated. Ensure that the chassis is spread before you turn a person in position at the boom over the bed or bath tub, sitting or lying in the sling. Page 4

5 4 Receipt The aks heavy-duty hoist has already been inspected at the factory for freedom from defects and completeness. Nevertheless, check the product immediately after receipt for possible transport damage. Check whether all parts are present using the delivery note and thus that the delivery is complete. If this is not the case, contact your aks authorised dealer. 5 Scope of delivery The aks heavy-duty hoist is delivered in two cartons: Carton I (Figure 01): mast / cantilever arm, rechargeable battery, wall charging station, mains power cable Carton II (Figure 02): chassis, boom, operating manual After removing all individual parts, check the completeness of the package contents. The standard scope of delivery consists of: 1 x heavy-duty hoist 1 x boom, depending on the order 1 x manual control unit 1 x removable rechargeable battery 1 x wall charging station Figure 01 Figure 02 Page 5

6 6 Overview aks goliath Cantilever arm Boom with padding Mast Drive (height adjustment) Rechargeable battery Chassis Double castors Manual control unit Control unit Drive (spreading) Figure 03 Page 6

7 7 Commissioning 1. Fetch the chassis from the carton and place it on level ground. 2. First lock the brakes of the rear castors and then remove the star handle bolt from the hole. For this, first remove the split pin (Figure 04). 3. Now you can insert the mast in the middle tube on the chassis (Figure 04). In doing so, ensure that the cantilever arm faces in the direction of travel. Lock the mast by inserting the star handle bolt in the hole and secure it afterwards with the split pin (Figure 05). Now tighten the clamping lever on the middle tube of the chassis. Figure 04 Figure Now remove the cable tie which holds the cantilever arm and mast together as transport lock. In order to fix the motor, remove the bolt from the retaining plate on the cantilever arm. Raise the cantilever arm and align the drill hole of the lift tube with that of the cantilever arm. Then insert the bolt again and lock using the locking plate (Figure 06). Figure 06 Page 7

8 5. Remove the retaining bolt with collar at the end of the cantilever arm for the mounting of the boom. Then insert the retaining bolt from below through the mounting hole of the boom. Then mount the retaining bolt with boom on the cantilever arm. Finally, pay attention to the correct application of the locking plate at the bolt (Figure 07). 6. Connect the spreader motor to the control unit. Check the plug connections on the control unit (Figure 08). It contains the following connection sockets: 1 = manual control unit 2 = lift motor 3 = spreader motor 4 = (not assigned) 7. The rechargeable battery must be charged for 18 hours before the first use of the hoist. Proceed according to section 8.6 / 8.7 Rechargeable battery. 8. Attach the charged battery to the control unit from above. Ensure that it engages and is seated firmly. 9. Unlock the EMERGENCY STOP button if it has been pressed by turning anticlockwise. 10. Finally, establish the safe condition of the hoist using the maintenance schedule. Figure 07 Figure 08 Page 8

9 8. Operation 8.1 Parking brake The parking brake is one of the important safety elements of a heavy-duty hoist. Your aks heavy-duty hoist is fitted with pressure brakes which act directly on the wheels. When the locking lever is pressed up to the stop, the brakes are locked and your aks heavy-duty hoist can no longer be moved (see Figure 10). Pull the lever up to release the brakes again (Figure 09). Attention! Always lock both castors. When only one castor is locked on a sloping floor, the unlocked wheel rolls downwards around the braked wheel. Depending on the slope of the floor, sideways tipping over can be expected. released locked Figure 09 Figure 10 Page 9

10 8.2 Manual control unit The drives are controlled using the manual control unit (Figure 11). Press the appropriate button to activate the required function. If a signal tone is heard when pressing any button, this indicates the battery capacity is too low. The rechargeable battery should be charged now. Height adjustment Spread adjustment Figure 11 Attention! If any operation of the control unit is performed despite the charge signal, the rechargeable battery can be destroyed by deep discharge. 8.3 Spreading You should increase the stability of the hoist before you lift any person with the hoist. This is achieved by spreading the chassis with an electric motor by operation of the manual control unit (figures 12 / 13). Figure 12 Figure 13 Page 10

11 8.4 EMERGENCY STOP button The control unit of the aks heavy-duty hoist is equipped with an EMERGENCY STOP button (Figure 14). The power circuit of the drives is interrupted immediately by pressing the red EMERGENCY STOP button on the control unit. This function enables you to avoid damage in emergencies. The button is unlocked again by turning it anticlockwise. EMERGENCY STOP button Electrical emergency lowering Figure Emergency lowering Mechanical emergency lowering: The aks goliath is equipped with mechanical emergency lowering for the case of any electrical defect on the motor or complete discharge of the rechargeable battery. This enables a retracting movement to be performed despite power supply failure. Requirement for this: the drive must be loaded in the compression direction. Pull the red release button in the direction of the piston rod eye for this. The lowering speed is dependent on the pulling intensity and on the static load on the drive. The drive can be prevented from retracting at any time by releasing the release button again. The emergency lowering operates with a load from 100 to 150 kg. The drive is operational when the emergency lowering has been ended. Electrical emergency lowering: Figure 15 Electrical emergency lowering is possible in the event of failure of the manual control unit. For this, use an object similar to a pin to press the Emergency button underneath the EMERGENCY STOP button (Figure 14). Page 11

12 8.6 Wall charging station Together with a second rechargeable battery, the wall charging station allows continuous use of the heavy-duty hoist. The wall charging station must be mounted upright on a wall (figures 16 / 17) before commissioning. The mounting rail is attached to a flat and firm wall for this. The type of fastening is dependent on the wall material. Use plugs and screws in accordance with the condition of the wall. The charger can now be pushed onto the lower part of the mounting rail and fastened using the supplied M5x10 mm screw. Now plug the device connector of the mains cable into the connection socket of the charger. Ensure that the device connector engages and cannot be pulled out. Attach the cable hook to the charger by pushing it onto the plug-in sockets from above. Hang the mains cable on the cable hook if you unplug the mains plug. The mains power cable must not lie on the floor. Mechanical loading of the mains power cable (e.g. driving over the mains power cable) must be avoided. Rechargeable battery Mounting rail Mains power cable with device connector (red) Cable hook Charger Figure 16 Figure 17 Page 12

13 8.7 Rechargeable battery The aks goliath is equipped with a removable rechargeable battery pack. Together with the wall charging station and a second rechargeable battery pack, flexibility, mainly in the stationary area, is guaranteed. Figure 18 General: Some basics should be observed for handling the rechargeable battery pack: It is recommended to charge the rechargeable battery for approx. 18 hours before first use to compensate for possible loss of capacity during storage. The rechargeable battery should be charged with an ambient temperature between 0 C and 40 C. The most effective charging temperature range is between 5 C and 35 C. The rechargeable battery must not be charged at temperatures below 0 C or above 40 C. The rechargeable battery system (control unit) is equipped with an audible signal transmitter. The audible charge signal is emitted when a button on the manual control unit is pressed. The rechargeable battery must be charged now. If any operation of the control unit is performed despite the charge signal, the rechargeable battery can be destroyed by deep discharge. The rechargeable batteries must be replaced after 4 years at the latest, depending on the usage intensity and possibly also even earlier. Frequent and rapid discharge reduces the service life of the rechargeable batteries. The rechargeable batteries should be connected to the mains power supply as often as possible to achieve optimum service life. The rechargeable batteries must be charged at the latest every three months otherwise they will be damaged due to self-discharging. If the rechargeable batteries are stored over a longer time, it is recommended to recharge them at the following time intervals: At a storage temperature of approx. 20 C, the rechargeable battery must be recharged every 5 months. Note: After long storage, all rechargeable batteries have smaller capacity than the rated capacity during the first cycle. In parallel operational readiness, the full capacity during charging is generally achieved within hours. Due to the reduction of the charging current during the charging process, the rechargeable battery is charged approx. 80% 4-5 hours after the charge signal sounds. A charging time of 10 hours is required to reach 100% charge. The rechargeable battery must be completely replaced if defective. Page 13

14 Charging process: Reach into the recessed grip at the top on the rechargeable battery pack to remove the rechargeable battery pack. Press the lever in the recessed grip and then lift the rechargeable battery pack out of the locking mechanism (Figure 19). Place the rechargeable battery pack on the wall charging station from above (Figure 17). In doing so, ensure that the rechargeable battery pack engages in the fixing rail. Connect the wall charging station to the mains power supply to start the charging process. The green LED ( ON ) signals the operational readiness and the yellow LED ( CHARGE ) indicates the charging process. Figure 19 9 Patient sling You need a patient sling to be able to lift a patient with the aks heavy-duty hoist. This should correspond to both the size, weight and condition of the patient as well as the intended action. The following describes attaching a standard patient sling to a lying patient: 1. Turn the patient so that he is facing away from you. 2. Roll up the patient sling in half in the longitudinal direction. 3. Place the patient sling with the rolled up side next to the patient. 4. Now turn the patient back on his back and pull the patient sling straight. 5. Now attach the patient sling loops in the sling eyelets on the boom. ATTENTION! Damaged or severely worn body support systems (patient slings) must not be used. Page 14

15 10 Accessories / combination Only original aks accessory parts should be used as accessories because these are tested by ourselves and thus guarantee faultless and safe functioning. Accessories: Boom Hoist sling Other accessories on request. Combination: You can also use other products from the company aks with the aks heavy-duty hoist. For example, these include our aks antidecubitus systems or our aks homecare beds range. ATTENTION! If accessories not shown are used or the hoist is used in combination with other products, the owner and the user are solely responsible to ensure reliable and safe operation. This combination must not be used if there is a possible recognised hazard. The responsible aks authorised dealer is pleased to help in the case of questions. Page 15

16 11 Care / cleaning The aks heavy-duty hoist is suitable for manual cleaning with a moist cloth. Cleaning and care materials suitable for plastic furniture can be used as cleaning materials. The following points must be noted here: Do not use any abrasive agents or cleaning materials containing ammonium chloride. Only use dermatologically tested materials. Do not use any basic and alkaline cleaning agents. Do not use any aggressive cleaning materials, e.g. solvents and hard brushes etc. Do not dip the electrical components in water. Only clean these with a slightly moist cloth. All hoist slings available from aks are machine-washable up to maximum 60 C. Do not iron! 12 Storage The storage location should preferably be cool, dry and dark. It should not exceed the normal room temperature. Direct sunlight must be avoided. The climatic conditions should be an ambient temperature from +15 C to +40 C, relative humidity from 25% to 85% and air pressure from 700 hpa to 1060 hpa. The aks heavy-duty hoist must be cleaned at the latest when it is used again and must be serviced as described under chapter 17 Maintenance. In the case of longer storage, note the point 8.7 Rechargeable battery. Page 16

17 13 Reuse The hoist must be cleaned at the latest when it is used again and must be serviced as described in chapter Disposal If the hoist has outlived its purpose, ask the local disposal company about the type of disposal. Each local authority has different regulations concerning this which can also change over the course of time. 15 Warranty The aks goliath is distinguished by its long service life and high reliability. Nevertheless, should technical problems arise, do not attempt to rectify the fault yourself. Contact your local authorised dealer. The dealer will provide assistance as quickly as possible and acquire all necessary spare parts if applicable. We guarantee our hoists for faultless condition in the context of our delivery and payment conditions. We make a factory warranty of 24 months from date of purchase. ATTENTION! Non-observance of the operating manual, improperly carried out maintenance work, and technical modifications and additions (attachments) without the permission of the aks company result in voidance of the warranty and general product liability. Page 17

18 16 Service life The service life for hoists in the domestic area is of course dependent on the type of use. Frequent adjustment, transport, installation and washing reduce the service life as do improper handling, irregular maintenance and exceeding the load cycles of the drives or the safe working load. 17 Maintenance General maintenance instructions The service life of the aks heavy-duty hoist is basically affected by the handling. Frequent adjustment and transport reduce the service life as do improper handling, incorrect maintenance and exceeding the load cycle of the drives or the payload. In order to ensure safe operation, a visual inspection and functional check with electrical inspection afterwards should be carried out at least annually. If the aks heavy-duty hoist is not maintained properly, safe use is no longer guaranteed. Wear, damage or also loosening of connecting elements can thus not be detected. In the case of damage and defects, inform your aks authorised dealer who will replace these parts. In the case of damage to load-bearing parts or the electrical system, the aks heavy-duty hoist must no longer be used. The electrical system consists of individual components such as adjustment drives, control unit, rechargeable battery and manual control unit. These closed units are maintenance-free and must not be opened. The modular design of the hoists allows replacement of individual components in the event of defects. Only original aks spare parts must be used, otherwise any warranty is void. You must not make any technical modifications and additions (attachments) without permission from aks. Only use the supplied individual parts for the aks heavy-duty hoist. Improper handling such as knocking, hitting, bumping release us from any warranty claim. Page 18

19 The Medical Products Operator Regulations are binding for the operator / user of medical products. The operator / user of electrically operated patient hoists is obliged according to the applicable accident prevention regulations BGV A3 to inspect these using a qualified electrician. According to VDE , this inspection must contain the following points: Visual inspection Insulation resistance measurement Leakage current measurement Functional check Overall assessment Service: If you have questions or need assistance, please contact your authorised dealer who is instructed in accordance with our guidelines and can provide advice, service and repairs. We have a network of dealers across Europe. This ensures that your requirements can be satisfied optimally. Page 19

20 18 Maintenance schedule The maintenance must be performed at least annually and before each reuse. Note: If the error rate in your company for the electrical measurements (DIN VDE :2001) is <2%, BGV A3 allows you as operator to increase the maintenance intervals to 2 years. The mains power connection cable must be at least visually inspected regularly at short intervals (e.g. monthly and after every occurring mechanical load) with respect to mechanical damage. Check of the basic requirements Appropriate and safe use Permitted accessories or equipment combination Boom used (enter here): Patient sling used (enter here): Rating plate present Presence of operating manual Inspection of the mechanical parts No unauthorised interventions, modifications or improper handling No soiling (in particular the lift tubes) No surface damage or corrosion Castors (undamaged and fastened) Spreading mechanism (undamaged and fastened) Mast (fastening of the clamping lever, locking bolt with split pin, weld seams) Cantilever arm (fastening to mast, weld seams) Chassis (weld seams) Boom (padding, fastening with bolt and locking plate, retaining bolt for signs of wear, e.g. embedding, replace) Patient sling (no damage such as cracks or holes, seams) Drive (fastening to mast and cantilever arm with bolt and locking plate) Control unit (fastening to mast) Inspection of the electrical parts Wall charging station (connector, cable, case, rating plate / lettering, indicators) Case (drive, control unit, manual control unit) Cables (manual control unit cable, connection cables, plug connections with sealing ring) Battery charger connection (green LED indicates the correct connection of the battery charger) Charging indicator (yellow LED shows the charging process) Note service life of the rechargeable batteries (batteries must be replaced every 4 years at the latest) Electrical inspection according to DIN VDE :2001 Insulation resistance measurement (greater than 7 MΩ) Replacement units leakage current measurement (max. 0.2 ma) Functional check A lifting cycle without load (traverse complete adjustment range, easy running, speed, limit switch in both directions, power consumption, no unusual noises) A lifting cycle with maximum load of 250 kg (observe self-locking) Castors (handling, easy running, no unusual noises) Brakes (reliability, locking) Manual control unit (first failure safety: no function of the manual control unit with rotary switch position I or II) EMERGENCY STOP button functions Mechanical emergency lowering functions Overall assessment Hoist OK Date Company Inspector Signature YES NO Page 20

21 19 Technical data Overall height: Attachment height: Chassis width: Chassis length: Ground clearance: Total weight: Individual weight: Individual weight: Load bearing capacity: Castors: Climatic conditions: Input voltage: Duty cycle: Protection type: 132 cm 58 cm to 198 cm 70.5 cm to 116 cm Technical Data 128 cm (including castors) 14 cm 53 kg 24 kg (mast with cantilever arm and rechargeable battery) 28.5 kg (chassis) 250 kg ø 100 mm (2 with and 2 without individual wheel brake) - ambient temperature from +5 C to 40 C - relative humidity from 20% to 90% Electrical data (control unit) 24 V DC (rechargeable battery capacity: 2.9 Ah) 2/18-2 minutes continuous operation followed by 18 minutes pause IP X5 Protection class: Application part: Protection type: Mains voltage: Charging current: Electrical data (wall charging station) II (not suitable for applications in potentially explosive atmosphere) Type B IP X4 100 V to 240 V (50 / 60 Hz) up to 650 ma Explanation of the symbols Protection class II Type B Observe accompanying papers Only suitable for dry indoor areas This product complies with the essential safety requirements which are mentioned in the basic requirements of the EU Council Directive 93/42/EEC about medical products. All parts and data are subject to constant further development and can thus be different from the information shown in this document. Page 21

22 20 Declaration of conformity Page 22

23 Enter the serial number of your patient hoist here: Serial number: Enter the year of manufacture of your patient hoist here: Year of manufacture: Enter the telephone number and name of the contact person of your aks authorised dealer here: Name: Telephone number: Notes: Page 23

24 Published by: aks aktuelle krankenpflege systeme GmbH Antwerpener Straße Troisdorf Tel: / Fax: / aks@aks.de website: Reprints whether in whole or in part are only allowed with the previous permission of the publisher. All rights reserved. We reserve the right to make changes.

aks-efw 300 Fastening set with weighing hanger for hoist scales with EC calibration Operating manual (translation of the original operating manual)

aks-efw 300 Fastening set with weighing hanger for hoist scales with EC calibration Operating manual (translation of the original operating manual) Fastening set with weighing hanger for hoist scales with EC calibration Operating manual (translation of the original operating manual) Date: 2012_01 Page 2 TABLE OF CONTENTS 1 Introduction 4 2 Intended

More information

aks-clino II Patient hoist Operating manual

aks-clino II Patient hoist Operating manual Patient hoist Operating manual Date: 2011_12 Page 2 TABLE OF CONTENTS 1 Introduction 4 2 Intended purpose 5 3 General safety instructions 6 4 Scope of delivery 7 5 Product description 8 6 Assembly 10 7

More information

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.

More information

aks-dualo Patient hoist Operating manual

aks-dualo Patient hoist Operating manual Patient hoist Operating manual Date: 2012_12 TABLE OF CONTENTS 1 Introduction 3 2 Intended purpose 4 3 General safety instructions 5 4 Scope of delivery 6 5 Product description 7 6 Assembly 11 7 Commissioning

More information

Assembly and Operating Instructions

Assembly and Operating Instructions A35AE FU...A150AE FU en Assembly and Operating Instructions Plug-in drives Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be kept safe for

More information

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology ENGLISCH Catalyser 2300-0001 1. Introduction We are pleased with your decision to purchase the Catalyser. Please read the following operating instructions carefully and observe the safety information they

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use! Operating instructions Pneumatic Crimper AC 100 Date of issue: 05/2010 Keep for future use! SAFETY SAFETY Basic information The basic prerequisite for ensuring safe use and continuous operation of the

More information

All-in-One Hoist User Manual , , ,

All-in-One Hoist User Manual , , , All-in-One Hoist User Manual 25-20010, 25-20020, 25-20030 25-20040, 25-20050 PDF 5946 Nov-2010 General about the hoist Index General about the hoist 3 Operation Operating instructions 4 Battery charging

More information

Adjustable Speaker Mount GRAVIS 12

Adjustable Speaker Mount GRAVIS 12 Adjustable Speaker Mount GRAVIS 12 User's Manual Translation of the original instructions Version 3.3 Released: 19.01.2017 Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße

More information

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA Installation and operating instructions Solar charge controller 10 A / 15 A / 0 A / 30 A EN 74.86 08.4 1. About this manual These operating

More information

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 8 Adjustable Speaker Mount GRAVIS 8 User's Manual Translation of the original instructions Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße 14 D-30179 Hannover TEL +49 (0)

More information

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions. Instruction Manual ENGLISH Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions. BIBO QUICK START GUIDE Insert the bibo Mouthpiece into

More information

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3

More information

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference! Tension Meter FT Series S C H M I D T c o n t r o l i n s t r u m e n t s Edition FT 03.E Model FT Instruction Manual Valid as of: 01.09.2011 Please keep the manual for future reference! Contents 1 Warranty

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

PURE SINE WAVE DC TO AC POWER INVERTER

PURE SINE WAVE DC TO AC POWER INVERTER PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read

More information

ACROBAT SWING STAND MODEL

ACROBAT SWING STAND MODEL Mounting instructions Directions for use ACROBAT SWING STAND MODEL Dr. Mach GmbH u. Co.KG, Flossmannstrasse 28, D-85560 Ebersberg Tel.: +49 (0)8092 2093 0, Fax +49 (0)8092 2093 50 Internet: www.dr-mach.com,

More information

HST -LS Interlocking device (Translation of Original Manual)

HST -LS Interlocking device (Translation of Original Manual) Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

SOLAR CHARGE CONTROLLER

SOLAR CHARGE CONTROLLER SOLAR CHARGE CONTROLLER SCE 1010 / SCE 1515 / SCE 2020 / SCE 3030 Instruction Manual Please read user manual carefully before use. 1.About this manual These operating instructions are part of the product.

More information

Operating Instructions

Operating Instructions Operating Instructions Repair Light > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage and Disposal...6

More information

MANUAL. Single charger

MANUAL. Single charger MANUAL Single charger HST-PR-2830 & HST-PR-2830USA for HS-Technik batteries HST-PR-18xx HST-PR-14xx issue date: November 2016 Table of contents Page 1. Basic information...3 1.1. Purpose of this document...3

More information

Battary powered cutting tool. AS6-S32 Art convincing solutions. Video

Battary powered cutting tool. AS6-S32 Art convincing solutions. Video Hydraulic cutting tool Smart Line Operating instructions Battary powered cutting tool AS6-S32 Art. 216419 Video 216419 convincing solutions 1. Technical data Area of application: Separating copper and

More information

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN CORDLESS WORK LIGHT CORDLESS WORK LIGHT Operation and Safety Notes IAN 279345 GB / IE / NI Operation and Safety Notes Page 5 A HG01386A-BS HG01386B-BS 1 5 2 6 3 4 7 8 10 9 B C 11 12 13 Introduction...Page

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709 MANN+HUMMEL ENTARON XD Installation and Maintenance Manual Version 0709 Contact information This installation and maintenance manual is a component part of the scope of delivery. It must be kept in a safe

More information

Operating instructions Accu Jet

Operating instructions Accu Jet Operating instructions Accu Jet Keep for future use! Ident number: 04.8800.000 Air Line Table of contents 1 Scope of delivery... 4 2 Operator instructions... 5 3 Safety... 6 3.1 Intended use...8 4 Description

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

MADITA-Fun mini. the therapy chair for initial assistance. Instructions for use

MADITA-Fun mini. the therapy chair for initial assistance. Instructions for use MDIT-Fun mini the therapy chair for initial assistance Instructions for use Dear Customer, t this point we would like to thank you for placing your trust in our company and for purchasing our product.

More information

L Charger. Instruction manual

L Charger. Instruction manual L 1039-10 Charger Instruction manual Contents Contents Contents... 1 Important safety instructions... 2 Package contents... 3 The L 1039-10 charger... 3 Product overview... 4 Putting the charger into operation...

More information

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810 5 IN 1 JUMP START MODEL NO: JS5IN1 PART NO: 6240005 OPERATION & MAINTENANCE INSTRUCTIONS LS0810 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

Battery powered cutting tool. AS6ST-20 Art convincing solutions. Video

Battery powered cutting tool. AS6ST-20 Art convincing solutions. Video Hydraulic cutting tool Smart Line Operating instructions Battery powered cutting tool AS6ST-20 Art. 216418 Video 216418 convincing solutions 1. Technical data Area of application: Separating copper and

More information

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions AQUATEC R / AQUATEC F / AQUATEC XL Bathlift Operating instructions 1 2 3 4 5 6 7 8 9 10 11 Contents 1 General instructions................. 3 1.1 Introduction......................... 3 1.2 Proper use.........................

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

2 TONNE TROLLEY JACK

2 TONNE TROLLEY JACK 2 TONNE TROLLEY JACK 61829 IMPORTANT: Please read these instructions carefully to ensure the safe and effective use of this product and save these instructions for future reference. This manual has been

More information

Lumitester PD-20 Control Kit

Lumitester PD-20 Control Kit 日本語による取扱説明は 17 ページからとなります Lumitester PD-20 Control Kit Operation manual Thank you for purchasing the Lumitester PD-20 Control Kit. To use this kit safely and correctly, read this operation manual carefully

More information

Instruction manual Electric glass door lock Touch-to-open

Instruction manual Electric glass door lock Touch-to-open Instruction manual Electric glass door lock Touch-to-open OPERATING INSTRUCTIONS Touch to open electric glass door lock Operating instructions draft 09-2017_v1 Content 1 General 1.1 Performance Description

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

Katalysator Nr /

Katalysator Nr / Katalysator Nr. 2300-0001 / 2300-3001 Bedienungsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones de servicio Инструкция по эксплуатации 取扱説明書 사용설명서 21-6499 15092017 Made in Germany

More information

Operating instructions

Operating instructions Operating instructions Type TEKA filtoo TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72 E-Mail:

More information

OPERATIONS MANUAL LEVER CHAIN HOIST

OPERATIONS MANUAL LEVER CHAIN HOIST OPERATIONS MANUAL LEVER CHAIN HOIST IMPORTANT SAFETY INFORMATION Please read, understand and follow all safety information contained in these instructions prior to the use of this hoist. Retain these instructions

More information

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5 CONTENTS IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5 OPERATION 8 SPECIFICATIONS 8 MAINTENANCE 9 HOME CHARGER MODE 2 Series 31328 to 31340 16/32A single phase FCC INFORMATION 9 WARRANTY

More information

2.0Ah BATTERY INSTRUCTION MANUAL

2.0Ah BATTERY INSTRUCTION MANUAL BATTERY SAFETY WARNINGS THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR YOUR BATTERY. 2.0Ah BATTERY INSTRUCTION MANUAL SPECIFICATIONS Input: Battery Capacity: Power Consumption: Weight:

More information

Battery Charger JCB- SCH20LI.2

Battery Charger JCB- SCH20LI.2 Safety and operating manual Battery Charger JCB- SCH20LI.2 ORIGINAL INSTRUCTIONS SAFETY INSTRUCTIONS WARNING: Read all safety warnings and all instructions.failure to follow the warnings and instructions

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

Instruction manual. Liftkar HD Uni Liftkar HD Fold Liftkar HD Dolly Liftkar HD Fold Dolly. Issued: 10/2010 subject to updates.

Instruction manual. Liftkar HD Uni Liftkar HD Fold Liftkar HD Dolly Liftkar HD Fold Dolly. Issued: 10/2010 subject to updates. Instruction manual Liftkar HD Uni Liftkar HD Fold Liftkar HD Dolly Liftkar HD Fold Dolly Issued: 10/2010 subject to updates. en Contents 1 INTRODUCTION AND KEY FEATURES... 3 1.1. General safety guidelines...

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

Yesterday s challenge Today s solution. User Manual. innova.uk.com

Yesterday s challenge Today s solution. User Manual. innova.uk.com Yesterday s challenge Today s solution User Manual innova.uk.com Contents 2 www.innova.uk.com Contents Contents 1. Purpose & Use 1.1 Introduction 4 1.2 Who are Innova? 5 1.3 Unpacking & preparation 6 1.4

More information

Table of contents 1 Introduction 2 Suitability 3 General safety instructions 4 Adjustments 24 5 Seat location selection and adjustment

Table of contents 1 Introduction 2 Suitability 3 General safety instructions 4 Adjustments 24 5 Seat location selection and adjustment Table of contents...... 1 Introduction................................. 20 2 Suitability.................................. 20 3 General safety instructions....................... 21 4 Adjustments.................................

More information

SGA-440 by Prism Medical

SGA-440 by Prism Medical SGA-440 by Prism Medical Introduction... 2 Overview... 2 Components of the Sit to Stand Lift... 3 Component List... 4 Specifications... 5 Cautions... 6 Assembly Instruction... 7 Operation Charging......12

More information

Pallas/150. Stand-aid lifter. User instruction. Important - information. This user instruction must be read before the Pallas 150 is used.

Pallas/150. Stand-aid lifter. User instruction. Important - information. This user instruction must be read before the Pallas 150 is used. Pallas/150 Stand-aid lifter User instruction Important - information This user instruction must be read before the Pallas 150 is used. This user instruction is intended for technicians, installers, therapists

More information

Installation Instructions

Installation Instructions Installation Instructions ELEKTROMAT SE 15.48-25,40 NOT DEFINED Model: 10004112 10006 -en- Status: 21.07.2016 2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom

More information

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

HYDRAULIC PALLET TRUCK. MODEL No: PTE550 PART Nos OPERATION & MAINTENANCE INSTRUCTIONS

HYDRAULIC PALLET TRUCK. MODEL No: PTE550 PART Nos OPERATION & MAINTENANCE INSTRUCTIONS HYDRAULIC PALLET TRUCK MODEL No: PTE550 PART Nos 7630171 OPERATION & MAINTENANCE INSTRUCTIONS 0604 Please read these instructions carefully before operating the truck Thank you for purchasing this CLARKE

More information

Operating Instructions K Always on the safe side.

Operating Instructions K Always on the safe side. Operating Instructions K9 4953. Always on the safe side. KaVo Dental GmbH Wangener Straße 78 D-88299 Leutkirch Tel.: 0 75 61 / 86-150 Fax: 0 75 61 / 86-265 A 1 User information...2 A 1.1 Meaning of the

More information

Operating instructions ErgoPack 600 E

Operating instructions ErgoPack 600 E Operating instructions ErgoPack 600 E Operation of the device is only permitted if the operating instructions have been carefully read and understood before use! Declaration of conformity EU declaration

More information

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514 JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 PART NO: 6240040, 6240035 & 6240045 OPERATING & MAINTENANCE INSTRUCTIONS GC0514 INTRODUCTION Thank you for purchasing this CLARKE Jumpstart. Before attempting

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

3 TONNE TROLLEY JACK

3 TONNE TROLLEY JACK 3 TONNE TROLLEY JACK 16407 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent

More information

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual c-go 12V/10A 12V/20A Power supply and battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Mounting and installation... 4 4. Operation... 5 5. Problem solving...

More information

The Future of Homecare Lifting is Here!

The Future of Homecare Lifting is Here! HYDRAULIC OR BATTERY OPERATED MODEL:400H / 400EL / 400LK The Future of Homecare Lifting is Here! Thank you for choosing the BestLift 400 To better serve you, please record the following information: Dealer

More information

User Manual S Line Bed

User Manual S Line Bed User Manual S Line Bed Important Please read before operation Model SLLS001 2 Contents 1 Essential Information 5 1.1 Technical Specifications 5 1.2 Intended Use 6 1.3 Unintended Use 7 1.4 Transportation

More information

Prism A-205. Owner s Manual. Aluminium Mobile Hoist. Use and Care Trouble Shooting Warranty Information. Introduction Overview...

Prism A-205. Owner s Manual. Aluminium Mobile Hoist. Use and Care Trouble Shooting Warranty Information. Introduction Overview... Prism A-205 Aluminium Mobile Hoist Introduction... 2 Overview... 2 Components of the Mobile hoist... 3 Component List... 4 Specifications... 5 Cautions... 6 Assembly Instruction... 7 Operation Charging......13

More information

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH PrioVino Premier Translation of Original Operating Instructions Status: August 2018 First edition January 2018 / PrioVino GmbH Reprint even in extracts only upon written permission by PrioVino GmbH (ISO

More information

HYDRAULIC PALLET TRUCKS

HYDRAULIC PALLET TRUCKS HYDRAULIC PALLET TRUCKS HYDRAULIC PALLET TRUCKS MODEL Nos: PT550 GAL & PT685 GAL PART Nos: 7630234 & 7630236 OPERATION & MAINTENANCE INSTRUCTIONS 0204 Please read these instructions carefully before operating

More information

Solenoid Operator 0516 / 1216

Solenoid Operator 0516 / 1216 nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!

More information

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER PROFESSIONAL CORDLESS IMPACT SCREWDRIVER Model CIS00 Part No 4500625 OPERATING & MAINTENANCE INSTRUCTIONS GC0309 INTRODUCTION Thank you for purchasing this CLARKE Impact Screwdriver. Before attempting

More information

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R SONOTEC Ultraschallsensorik Halle GmbH Nauendorfer Straße 2 D-06112 Halle/Saale Tel: ++49-(0)345-13317-0 Fax:++49-(0)345-13317-99 http://www.sonotec.de e-mail: SONOTEC@sonotec.de Ultrasonic Leak Detector

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

COBRA Indoor base with gas pressure spring and 45 tilt function user manual

COBRA Indoor base with gas pressure spring and 45 tilt function user manual COBRA Indoor base with gas pressure spring and 45 tilt function user manual - Partnering together to mobilise kids User manual for COBRA indoor base with gas pressure spring and 45 tilt Index 1 Common

More information

Yesterday s challenge Today s solution. User Manual. innova.uk.com

Yesterday s challenge Today s solution. User Manual. innova.uk.com Yesterday s challenge Today s solution User Manual innova.uk.com Contents 2 www.innova.uk.com Contents Contents 1. Purpose & Use 1.1 Introduction 4 1.2 About the manufacturer 5 1.3 Unpacking & preparation

More information

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN CORDLESS WORK LIGHT CORDLESS WORK LIGHT Operation and Safety Notes IAN 288518 GB / IE / NI Operation and Safety Notes Page 5 A HG01386A-BS 5 1 2 6 3 4 7 8 10 9 B C 11 12 13 List of pictograms used...page

More information

ON SAFEGUARD S ON SAFEGUARD M

ON SAFEGUARD S ON SAFEGUARD M instructions Retrofit option GB ON SAFEGUARD S ON SAFEGUARD M Insulating protective cover Observe additional system documents! General instructions CAUTION Read the operating instructions! The operating

More information

Free Standing Track. Owner s Manual. Use and Care Trouble Shooting

Free Standing Track. Owner s Manual. Use and Care Trouble Shooting Free Standing Track Owner s Manual Use and Care Trouble Shooting VANCARE, INC. 1515 1ST STREET, AURORA, NE 68818 T (800) 694-4525 F (402) 694-3994 info@vancare.com www.vancare.com Table of Contents Free

More information

ELECTRIC LIFTING HOIST

ELECTRIC LIFTING HOIST ELECTRIC LIFTING HOIST COMPLIES TO AS 1418 STANDARDS KP1201 125/250KG KP1202 400/800KG ED 2 / JULY / 15 TYPE 2 1 Table of Contents 1 Know Your Product...2 Electric Lifting Hoist Safety Instructions...3

More information

Contamination switch VS

Contamination switch VS Contamination switch VS RE 95148 Issue: 12.2015 Replaces: 09.2015 For detecting metallic impurities in oil Inhalt Ordering code 2 Description 2 Technical data 2 Connection 3 Dimensions 3 Safety instructions

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00. Operating instructions for operators sonnenprotect 1300 KD-337 Part no. 22010 Version X00 info@sonnenbatterie.de www.sonnenbatterie.de EN IMPORTANT Read this documentation carefully before operation. Retain

More information

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.: Operating manual HDA eco Box 12/24V DC Automatic Dispenser Item No.: 110 500 900 Translation of the original operating manual Important! Copyright The operating manual is always to be read before commissioning

More information

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type RSBW Assembly and Maintenance Manual Type RSBW Hatschekstr. 36 69126 Heidelberg Germany Tel +49(0)6221 30470 Tel +49(0)6221 304731 info@stieber.de www.stieber.de Stieber Clutch Date of issue: 16/03/2017 GB

More information

H-1274 OR-T 200. Battery-hand tool for plastic strapping. Before using the tool, read the operating instructions carefully. 08/07

H-1274 OR-T 200. Battery-hand tool for plastic strapping. Before using the tool, read the operating instructions carefully. 08/07 H- OR-T 00 Battery-hand tool for plastic strapping Before using the tool, read the operating instructions carefully. 08/0 ORGAPACK OR-T 00 Technical data TABLE OF CONTENTS General information Page. Information

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Electric Hi Lo Screen lift Trolley Mount 8960

Electric Hi Lo Screen lift Trolley Mount 8960 Electric Hi Lo Screen lift 750 - Trolley Mount 8960 - Max Capacity 100kg - Min Capacity 5kg - Screens upto 86 WARNING! THIS IS NOT A TOY! WARNING! CHILDREN SHOULD NOT OPERATE LIFT OR HAVE ACCESS TO THE

More information

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner Type 3372 Electropneumatic Actuator Actuator area: 120 and 350 cm² With Type 3725 Positioner Translation of original instructions Type 3372 with 120 cm² actuator area Type 3372 with 350 cm² actuator area

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

Team Trike Assembly Instructions for 8142 Models

Team Trike Assembly Instructions for 8142 Models Team Trike Assembly Instructions for 84 Models paper! Tools required for adult assembly Printed on 00% recycled KETTLER International Inc 355 London Bridge Road Virginia Beach, Virginia 3453 USA www.kettlerusa.com

More information

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1 T Series (N6052T) Solar Battery Hybrid System Installation Manual Version 1.1 Content 1. Safety... 1 1.1 How to Use This Manual... 1 1.2 Safety Rules... 1 1.3 Warning Notices Affixed to the Device... 2

More information

OFF-ROAD JACK SKU: HCRG-JACK48

OFF-ROAD JACK SKU: HCRG-JACK48 OFF-ROAD JACK SKU: HCRG-JACK48 SPECIFICATIONS...2 IMPORTANT SAFETY INFORMATION...3 UNPACKING AND ASSEMBLING JACK...3 Unpacking Carton...3 Testing Operation...3 OPERATING JACK...4 Preparing Work Area...4

More information

EASY CHARGE Weather-resistant fixed mount Battery Charger

EASY CHARGE Weather-resistant fixed mount Battery Charger EASY CHARGE Weather-resistant fixed mount Battery Charger 6 AMP AND 10 AMP MODELS EN NL, DE, FR, ES, IT USER S MANUAL WWW.MASTERVOLT.COM/EASYCHARGE 10000009118/01 2 EN / EasyCharge 6 and 10 Amp - User

More information

SOLAR CHARGE CONTROLLER N 2010 IN 2011/ N 2012/ N 2014

SOLAR CHARGE CONTROLLER N 2010 IN 2011/ N 2012/ N 2014 SOLAR CHARGE CONTROLLER N 2010 IN 2011/ N 2012/ N 2014 Instruction Manual Please read user manual carefully before use. CE 1.About this manual These operating instructions are part of the product. ~ Read

More information

DC Master 24/ A

DC Master 24/ A USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015

More information

STAND MODEL FOR MACH M2

STAND MODEL FOR MACH M2 Mounting instructions Directions for use STAND MODEL FOR MACH M2 Stand lamps: Mach M2... Mach M2 F... Order No. 170 120 1300 Order No. 170 230 1300 GmbH u. Co. KG, Flossmannstrasse 28, D-85560 Ebersberg

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Battery Charger JCB-FCH12Li

Battery Charger JCB-FCH12Li Safety and operating manual Battery Charger JCB-FCH12Li ORIGINAL INSTRUCTIONS SAFETY INSTRUCTIONS WARNING: Read all safety warnings and all instructions.failure to follow the warnings and instructions

More information

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions Type 3271 Pneumatic Actuator Actuator area: 1000 cm² Translation of original instructions Type 3271 Pneumatic Actuator Mounting and Operating Instructions Edition April 2018 Note on these mounting and

More information

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information