RM4LG01M. Caracteristici Principale. 500 V conformitate cu IEC. Borne cu suruburi 2 x 2.5 mm², flexibil cablu fără terminale de cablu.
|
|
- Sarah Bennett
- 6 years ago
- Views:
Transcription
1 Fişă tehnică produs Caracteristici RM4LG01M Caracteristici Principale Gama de produse Zelio Control Tip produs sau componenta Relee industriale de masura si control Tip releu Liquid level control relay Nume releu RM4-L Parametri monitorizati ai releului Detectare prin sonde rezistive Tipintarziere Fără Puterea consumată în VA 2.4 VA c.a. Tip si compozitie contacte 1 C/O Complementare Tensiunea maximă de comutaţie 440 V c.a. [Us] tensiune nominală de alimentare V c.a. 50/60 Hz +/- 5 % Limite de tensiune circuit de comanda Contacte de iesire Tensiunea maximă a electrozilor Curentul maxim al electrozilor Capacitatea maximă a cablului Cable distance between devices Scala de sensibilitate Marcaj 0,85...1,1 Uc 1 C/O 24 V c.a. 1 ma 0 mf 100 m kohm CE : EMC 89/336/EEC CE : LVD 73/23/EEC Categorie de supratensiune III conformitate cu SR EN [Ui] tensiune nominală de izolaţie Valoare de decuplare a alimentarii Pozitie de operare Conexiuni - borne Cuplu de strângere Durabilitate mecanică [Ith] curent termic convenţional în aer liber 500 V conformitate cu IEC > 0,1 Uc Orice pozitie fara declasare Borne cu suruburi 2 x 1,5 mm², flexibil cablu cu pini Borne cu suruburi 2 x 2.5 mm², flexibil cablu fără terminale de cablu N.m cic 8 A [Ie] curent nominal de utilizare 2 A la 24 V DC C conformitate cu IEC / A la 24 V DC C conformitate cu VDE A la 115 V AC C conformitate cu IEC / A la 115 V AC C conformitate cu VDE A la 24 V AC C conformitate cu IEC / A la 24 V AC C conformitate cu VDE A la 250 V AC C conformitate cu IEC / A la 250 V AC C conformitate cu VDE A la 250 V DC C conformitate cu IEC / A la 250 V DC C conformitate cu VDE A la 115 V DC C conformitate cu IEC / A la 115 V DC C conformitate cu VDE 0660 Capacitatea de comutare în ma Tensiunea de comutaţie 10 ma la 12 V 250 V c.a. Material contacte Contacte din aliaj de argint cu nichel 90/10 Număr de cabluri 2 Lăţime Descriere borne ISO nr. 1 Stare releu de iesire Module de 9 mm mm ( )OC (A1-A2)CO (B1-B2-)CO According to chosen function Informaţiile oferite în această documentaţie conţin descrieri generale şi caracteristici tehnice legate de produsele prezentate. Această documentaţie nu este un substitut pentru şi nu trebuie folosită pentru a determina compatibilitatea şi fiabilitatea acestor produse în aplicaţiile specifice ale clienţilor. Este de datoria utilizatorului sau a integratorului să efectueze analiza completă de risc, evaluarea şi testarea produselor pentru utilizarea în aplicaţiile specifice. Schneider Electric Industries SAS şi filialele sale nu pot fi răspunzătoare pentru întrebuinţarea greşită a informaţiilor conţinute în această documentaţie. 1 / 6
2 Greutate produs kg Mediu compatibilitate electromagnetică standarde EN/IEC certificari produs Descărcare electrostatică - nivel de testare 6 kv, nivel 3 - descărcare pe contact conformitate cu IEC Descărcare electrostatică - nivel de testare 9 kv, nivel 3 - descărcare în aer conformitate cu IEC CSA GL UL temperatura de depozitare C temperatura de utilizare C umiditate relativă % 3K3 conformitate cu IEC rezistenta la vibratii 0.35 ms (f = Hz) conformitate cu IEC rezistenta la socuri 15 gn pentru 11 ms conformitate cu IEC grad de protectie IP grad de poluare 3 conformitate cu SR EN tensiune de încercare IP20 IP20 IEC IEC terminals IEC IEC conforming to IEC IP50 IP50 IEC IEC casing IEC IEC conforming to IEC kv rezistenţă la descărcări electrostatice 6 kv contact conformitate cu IEC nivel 3 8 kv aer conformitate cu IEC nivel 3 rezistenţă la câmpuri electromagnetice 10 V/m conformitate cu IEC nivel 3 rezistenţă la tranzienţi rapizi 2 kv conformitate cu IEC nivel 3 protecţia la electrocutare 2 kv: nivel 3 conformitate cu IEC perturbatie radiata/condusa CISPR11 grup 1 - clasa A CISPR22 - clasa A Contractual warranty Perioada 18 luni Liquid Level Control Relays Dimensions Liquid Level Control Relays Rail mounting 2 / 6
3 Screw fixing Liquid Level Control Relays RM4LG01 Wiring Diagram A1- A2, B1, B2, Supply voltage Electrodes (see table below) Electrodes and level controlled B1 B2 Reference or tank earth electrode High level Low level RM4LA32 Wiring Diagram 15-1st C/O contact of the output relay 18,15-16 A1- A2, B1, B2, Supply voltage Electrodes (see table below) 15-1st C/O contact of the output relay 18, / 6
4 25-28, nd C/O contact of the output relay Electrodes and level controlled B1 B2 Reference or tank earth electrode High level Low level Connection Examples Control by Electrodes (1) Supply voltage (2) High level (3) Low level Control by Probes (1) 2 levels (2) 1 level Electrical Durability and Load Limit Curves AC Load Curve 1: Electrical durability of contacts on resistive load in millions of operating cycles X Current broken in A Y Millions of operating cycles Curve 2: Reduction factor k for inductive loads (applies to values taken from durability Curve 1) X Power factor on breaking (cos φ) Y Reduction factor K 4 / 6
5 DC Load Load limit curve X Current in A Y Voltage in V 1 L/R = 20 ms 2 L/R with load protection diode 3 Resistive load Function Diagrams Empty Function Maximum level detection (2 electrodes or 1 probe LA9RM201) B2 High/low level electrode Regulation between a maximum and a minimum level (3 electrodes or 2 probes LA9RM201) B2 High level electrode Low level electrode 5 / 6
6 Fill Function Maximum level detection (2 electrodes or 1 probe LA9RM201) B2 High/low level electrode Regulation between a maximum and a minimum level (3 electrodes or 2 probes LA9RM201) B2 High level electrode Low level electrode NOTE: On RM4LA32, a time delay can be set on energization or de-energization of the output relay. 6 / 6
RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A
Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial
More informationNume companie: Creat de: Telefon: Date:
Poziţie Cant. Descriere ALPHA2 25-8 Nr. Produs: 98649753 Notă! Poza de produs poate diferi de produsul actual High-efficiency circulator pump with permanent-magnet motor (ECM technology) and integrated
More informationNume companie: Creat de: Telefon:
Poziţie Cant. Descriere 1 ALPHA3 25-6 13 Nr. Produs: La cerere High-efficiency circulator pump with permanent-magnet motor (ECM technology) and integrated electronic performance adaptation due to continuously
More informationINFORMAȚII DESPRE PRODUS SKINTOP ST-M
INFORMAȚII DESPRE PRODUS, presetupă din poliamidă cu rezistență crescută la uleiuri, cu domeniu de sigilare extins, protejată la vibraţii, pentru platforme maritime Informații Acum cu grad de protecţie
More informationFISA TEHNICA DATA SHEET
2.1 AFISOARE DE EXTERIOR CU LED LED OUTDOOR DISPLAYS MODELE: TYPES: DESCRIERE Sistem destinat pentru informarea calatorilor cu privire la circulatia trenului (numar tren, destinatie, via, numar vagon).
More informationNume companie: Creat de: Telefon:
Poziţie Cant. Descriere 1 MAGNA1-12 F Nr. Produs: 97924178 Notă! Poza de produs poate diferi de produsul actual MAGNA1 circulator pump with easy selection of pump setting The pump is of the canned-rotor
More informationNume companie: Creat de: Telefon:
Tender Text Nr. Produs: La cerere ALPHA3 25-60 180 High-efficiency circulator pump with permanent-magnet motor (ECM technology) and integrated electronic performance adaptation due to continuously variable
More informationNOUTATI IN OFERTA INTEC AUTOMATIZARI Echipament pentru legare la pamant vagoane/cisterne petroliere Earthing connections for tank or container filling
NOUTATI IN OFERTA INTEC AUTOMATIZARI Echipament pentru legare la pamant vagoane/cisterne petroliere Earthing connections for tank or container filling Static electricity represents a major threat to safety
More informationCreat de: Telefon: Date: Poziţie Cant. Descriere 1 MAGNA Nr. Produs:
Poziţie Cant. Descriere 1 MAGNA1 25- Nr. Produs: 97924145 MAGNA1 circulator pump with easy selection of pump setting The pump is of the canned-rotor type, i.e. pump and motor form an integral unit without
More informationRPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A
Characteristics power relay plug-in - Zelio RPF - 2 NO - 120 V AC - 30 A Product availability : Stock - Normally stocked in distribution facility Price* : 12.69 USD Main Range of product Series name Product
More informationRUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED
Characteristics universal plug-in relay - Zelio RUM - 2 C/O - 120 V AC - 10 A - with LED Product availability : Stock - Normally stocked in distribution facility Price* : 13.79 USD Main Range of product
More informationNume companie: Creat de: Telefon:
Poziţie Cant. Descriere 1 MAGA1 32-8 r. Produs: 97924164 otă! Poza de produs poate diferi de produsul actual MAGA1 circulator pump with easy selection of pump setting The pump is of the canned-rotor type,
More informationSistem de alimentare backup sau sursa neintreruptibila de putere (UPS)
Sistem de alimentare backup sau sursa neintreruptibila de putere (UPS) Intreruperile de energie electrica, cauzate de caderile de tensiune din reteaua publica, pot produce uneori defecte majore in echipamentele
More informationNume companie: Creat de: Telefon:
Date: 12/15/215 Poziţie Cant. Descriere 1 MAGA3 25-1 r. Produs: 97924247 otă! Poza de produs poate diferi de produsul actual MAGA3 More than a pump With its unrivalled efficiency, all-encompassing range
More informationRE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC
Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical
More informationNume companie: Creat de: Telefon:
Poziţie Cant. Descriere 1 MAGA3 32-8 F r. Produs: 98333874 otă! Poza de produs poate diferi de produsul actual MAGA3 More than a pump With its unrivalled efficiency, all-encompassing range and built-in
More informationNume companie: Creat de: Telefon:
Poziţie Cant. Descriere 1 MAGA3 25- r. Produs: 97924247 MAGA3 More than a pump With its unrivalled efficiency, all-encompassing range and built-in communication capabilities plus functionalities replacing
More informationRE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC
Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Main Range of product Product or component type Electrical connection Discrete output type Contacts type and composition
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationDescription. Positive safety relays
Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional
More informationSquare D General Purpose Relays
Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................
More informationCOMPONENTE PENTRU SISTEMUL DE PROTECTIE - LOCAB
COMPONENTE PENTRU SISTEMUL DE PROTECTIE - LOCAB LOCAB este un sistem de tevi de protectie si componente care se utilizeaza la pozarea rigida si/sau elastica a cablurilor electrice de forta, comanda, control,
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationTeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30
Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,
More informationK30H001YP cam star-delta switch - 3-pole A - screw mounting
Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationAE 9... AE 40 Contactors NE... Contactor Relays
Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationXMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O
Characteristics pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Product availability : Non-Stock - Not normally stocked in distribution facility Main Range of product Product or component
More informationCharacteristics TeSys contactors 0 TeSys k contactors and reversing contactors
90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp
More informationXCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx
Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ
More informationBuc. 2,0. Buc. 2,0. Buc. 2,0. Buc. 1,0
Firma BEMAS SRL Str. Uzinelor,1 Chisinau, Republica Moldova, MD-23 Tel: +373 (22) 429222, Fax:+373 (22) 42999 E-mail: office@bemasgroup.com, web: www.bemasgroup.com Data: 28/11/13 Catre: Directorul Apa-Canal
More informationXT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m
Characteristics capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 159.00 USD Main Range
More informationDouble insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators
Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)
Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product
More informationXB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS
Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device
More informationPendant control stations 6
Characteristics For control circuits Environment Conformity to standards EN/IEC 0-- EN/IEC 00-, UL 0, CSA C- n EN/IEC 0-- and EN/ISO 0: 00 for versions with trigger action Emergency stop Protective treatment
More informationXMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O
Characteristics pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Complementary Possible differential minimum at low setting Possible differential minimum at high setting Maximum permissible
More informationLC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition
Product datasheet Characteristics LC1F400E7 Complementary [Uimp] rated impulse withstand voltage Overvoltage category [Ith] conventional free air thermal current Main Range Product name Product or component
More informationDECLARAȚIA DE PERFORMANȚĂ
DECLARAȚIA DE PERFORMANȚĂ DoP No. 997 1. Cod unic de identificare al produsului-tip Pentru numarul produsului va rugam consultati lista atasata 2. Utilizare (utilizări) preconizată (preconizate): Igienă
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More informationLC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC
Product datasheet Characteristics LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 -
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationContact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France
Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on
More informationDECLARAȚIA DE PERFORMANȚĂ
DECLARAȚIA DE PERFORMANȚĂ DoP No. 14688 1. Cod unic de identificare al produsului-tip Pentru numarul produsului va rugam consultati lista atasata 2. Utilizare (utilizări) preconizată (preconizate): Igienă
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationLC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC
Product data sheet Characteristics LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 -
More informationK50F003UP cam changeover switch - 3-pole A - screw mounting
Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product
More informationK63F003UP cam changeover switch - 3-pole A - screw mounting
Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product
More informationTECHNICAL MANUAL MANUAL TEHNIC TANNER
/7 EHNIL MNUL MNUL EHNI NNER. Dimensions Dimensiuni. Installation Instalarea.3 Electrical diagrams Schema electrica.4 dditional sections Sectiuni aditionale.5 Order numbers od comanda IE Eire Great-ritain
More informationScheda prodotto Relè Series B
Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where
More informationACCESORII DEOSEBITE PENTRU VENTILATOARE
ACCESORII DEOSEBITE PENTRU VENTILATOARE Accesoriile pentru ventilatoare oferă protecție şi suport de montare pentru ventilatoare CC şi AC mici. Adecvate pentru aplicații industriale şi de calcul. Apărătorile
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationContactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30
Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable
More informationSafety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries
Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,
More informationXMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12
Characteristics Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short name Pressure
More informationAF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits
More informationXMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O
Characteristics pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O Product availability : Stock - Normally stocked in distribution facility Main Range of product Product or component type Pressure
More informationUL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated
11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF
More informationNSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals
NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low
More informationXMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O
Characteristics pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Main Range of product Product or component type Pressure sensor type Device short name Pressure sensor size Controlled
More informationXXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m
Characteristics Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m Product availability : Stock - Normally stocked in distribution facility Price* : 98.00 USD Main Range of product Sensor type
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationLimit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR
Presentation type XCR b XCR v With head for rotary movement operators, spring return to off position contact actuation position per direction Page / v With head for rotary movement operators, stay put
More informationAuxiliary contact blocks - with spring terminals Accessories
Auxiliary contact blocks - with spring terminals Accessories CA3-10S 1SBC101037F0014 Description The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. CA3
More informationXMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12
Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 0..10 V - NPN - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short name
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationXMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12
Characteristics Pressure sensors XMLR -1 bar - G 1/4-24VDC - 4..20 ma - PNP - M12 Complementary Current consumption Electrical connection Type of output signal Analogue output function Discrete output
More informationIntroduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction
Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection
More informationLC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC
Product datasheet Characteristics LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 -
More informationNF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationROBINETE INDUSTRIALE SUPAPE ŞI ACCESORII
SUPAPE ŞI ACCESORII HYDROSYSTEMS...a perfect fit Cod art. Art.-No. Dimensiune art. article/size "CE" Robinet cu sertar, scaun din alama turnata "CE" gate valves, cast brass seated Corp: GG-25 body: GG-25
More informationPrewired position switches FF series
2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationCX14 S4 1000X525 SMALL SIZE, GREAT MANOEUVRABILITY CX12-CX14
CX14 S4 1000X525 SMALL SIZE, GREAT MANOEUVRABILITY CX12-CX14 The CX electric pallet trucks are available in different versions equipped with MOSFET technology. They are suitable for carrying loads on smooth
More informationXCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16
Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 47.90 USD Main Range
More informationLimit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66
Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66
More informationG7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press
Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms
More informationAF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationGX 12/25 BASIC THE COMPACT STACKER
GX 12/25 BASIC THE COMPACT STACKER This compact sized stacker is the ideal solution to work in confined spaces and looks both powerful and reliable. The reduced width (800mm), the lateral driving system
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440
More informationLimit switches 3. Page 92. Page 92
Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards
More informationILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector
Characteristics integrated drive ILA with servo motor - 24..48 V - DeviceNet - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Phase
More informationAF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.
More informationQX18 AC S4 1000X680 THE PROFESSIONAL CHOICE QX 18 QX20 - QX20DL AC TECHNOLOGY
QX18 AC S4 1000X680 THE PROFESSIONAL CHOICE QX 18 QX20 - QX20DL AC TECHNOLOGY The QX pallet truck series meets the needs of a vast number of applications thus guaranteeing high performance, even during
More informationPresentation Soft starters 0 Altistart 48 soft start - soft stop units
Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled
More informationAnexa. Pompa peristaltica Masterflex C/L Variable-Speed Tubing Pump; 50 to 300 rpm, 115/230 VAC; Cod produs Masterflex EW
Anexa Pompa peristaltica Masterflex C/L Variable-Speed Tubing Pump; 50 to 300 rpm, 115/230 VAC; Cod produs Masterflex EW-77122-24 Specifications & Description Pump SeriesC/L Control TypeAnalog Variable
More informationSafety detection solutions
General, Preventa XY C Presentation are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which could cause injury to persons or damage either to machines
More informationPosition switches FR series
Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33
More informationXMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12
Characteristics Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC - 4..20 ma - NPN - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short
More informationNEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.
Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high
More informationILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector
Characteristics integrated drive ILA with servo motor - 24..36 V - CANopen - PCB connector Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1860.00 USD Main Range
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More information