A-dec 200 P RE-INSTALLATION GUIDE

Size: px
Start display at page:

Download "A-dec 200 P RE-INSTALLATION GUIDE"

Transcription

1 A-dec 200 P RE-INSTALLATION GUIDE This document contains technical specifications for installing the A-dec 200 equipment line. Contents Structural Requirements Utility Requirements Shipping Weights Documentation References Views and Dimensions Plumbing Plan and Elevation Views A-dec 200 Chair with Support Center; Plan View A-dec 200 Chair; Elevation A-dec 200 Delivery System; Plan View A-dec 200 Delivery System; Plan View with Elevation A-dec 200 Chair with Support Center, Cuspidor, and Assistant s Instrumentation; Plan View A-dec 200 Dental Light; Plan View A-dec 200 Dental Light; Plan View with Elevation Regulatory Information Rev B

2 Structural Requirements Dental Patient Chair Interface Requirement The dental chair requires a solid, level mounting surface that meets these minimum specifications: Weight of 1000 lbs. (4450 N) for chair, dental light, delivery system, and patient. Capability to anchor chair to the floor, with a minimum pullout load of 100 lbs. (445 N) for one anchor-bolt. Utility Requirements Air NOTE Job site construction should be completed before dental equipment installation (including finished floors, ceiling, plumbing, lighting, paint, etc.). CAUTION Local regulation requires licensed plumbers and electricians to install utilities. All plumbing and utilities must conform to prevailing local codes. CAUTION The manner and method for accessing utilities within the wall is the responsibility of the design team working on the project (dental dealer, architectural services, and contractors). Utilities must be accessible without the use of tools. 1/2" (13 mm) nominal pipe compression fitting protruding 2" (51 mm) from finished floor or wall, supplied by contractor. Right angle manual shut-off valve supplied by the dental dealer and installed by contractor. Air pressure and flow of psi ( kpa), 2.5 SCFM (71 L/min) during normal use; 7.5 SCFM (210 L/min) peak intermittent flow. Air plumbing to be flushed clean before final connection to dental equipment. Water 1/2" (13 mm) nominal pipe compression fitting protruding 2" (51 mm) from finished floor or wall, supplied by contractor. Right angle manual shut-off valve supplied by the dental dealer and installed by contractor. Water pressure and flow of 60 ± 20 psi (410 ± 140 kpa), 1.5 gpm (5.7 l/min), not to exceed 40 C (104 F). Water plumbing to be flushed clean before final connection to dental equipment. Central Vacuum Central vacuum supplier must specify plumbing up to floor box utility center and its termination point in the utility center. Wet systems: NOTE The delivery system comes with a selfcontained water bottle. Municipal water is required for the cuspidor. Plumbing to terminate with 5/8" (16 mm) outer diameter (O.D.) tube protruding 1" (25.4 mm) perpendicular to the floor. 10 ± 2 inhg, 9 SCFM minimum (254 ± 51 torr, 255 L/min minimum) Gravity Drain NOTE Gravity drains are needed only on systems with a cuspidor. 1-1/2" (38 mm) nominal pipe protruding 1" (25 mm) from finished floor. Trap to be placed in line, conforming to local codes, contractor-supplied. Floor mount only. Not recommended for wall mount utilities. Measurement Acronyms Acronym N psi KPa SCFM L/min SLM inhg/torr Definition newton pounds per square inch standard liters per minute standard cubic feet per minute liters per minute standard liters per minute inches/mm of mercury (pressure) Rev B

3 Electrical 1/2" (13 mm) conduit and box with a hospital-grade power receptacle supplied by the contractor. Wire box to conform to local codes. Top of the receptacle should not be higher than 5" (127 mm) above finished floor for fit within floor box. See the following table for voltage and amperage ratings: Chair Type Required Electrical Supply Amperage Rating Amperage Breakdown 240 Volt Chair VAC, Hz, 10 Amps minimum 100 Volt Chair 100 VAC, Hz 15 Amps min (20 Amps recommended) 120 Volt Chair VAC, Hz 15 Amps min (20 Amps recommended) 10 Amps max Hz: 2 Amps chair pump motor 1.4 Amps 300-watt power supply 2 Amps ancillary products 10 Amps max Hz: 3.5 Amps chair pump motor 3.1 Amps 300-watt power supply 2 Amps ancillary products 10 Amps max Hz: 3.5 Amps chair pump motor 2.8 Amps 300-watt power supply 2 Amps ancillary products Rev B 3

4 Shipping Weights Documentation References Product/Box A-dec 200 Chair A-dec 200 Delivery System A-dec 200 Support Center A-dec 200 Dental Light Est. Shipping Weight 337 lb. (153 kg) 53 lb. (34 kg) 66 lb. (30 kg) 24 lb. (11 kg) Installation Guides: A-dec 200 Installation Guide... p/n Service Guides: A-dec 200 Service Guide p/n Instructions for Use: A-dec 200 Instructions For Use.. p/n A-dec Equip. Asepsis Guide.... p/n Regulatory and Specifications.. p/n Full-Size Templates: NOTE Use only full-scale templates for locating plumbing and electrical. A-dec 200 Full Line Product.... p/n Rev B

5 Views and Dimensions NOTE The dimensional drawings in the following pages are not to scale and are for reference only. For complete accuracy, use the appropriate full-sized templates. Plumbing Plan and Elevation Views Width of floor box cover frame Rev B 5

6 A-dec 200 Chair with Support Center; Plan View " 877 mm 27" 686 mm 21" 533 mm (Between Armrest) 6" - 12" 152 mm-305 mm 67" 1702 mm " 857 mm " 854 mm 19" 485 mm 27" 686 mm Rev B

7 A-dec 200 Chair; Elevation (shown with chair-only for clarity) 7" 178 mm 4" 102 mm 57" 1448 mm 29" 737 mm " 38 mm To Top of Seat Cushion 74" 1880 mm 15" 381 mm " 114 mm 33" 838 mm (Baseplate Only) Rev B 7

8 A-dec 200 Delivery System; Plan View (shown with only system dimensions for clarity) 25" 635 mm 20" 508 mm 24" 610 mm 28" 711 mm 29" 737mm Rev B

9 A-dec 200 Delivery System; Plan View with Elevation (shown with only system dimensions for clarity) 25" 635 mm 20" 508 mm 24" 610 mm 28" 711 mm 29" 737mm 24" 610 mm Rev B 9

10 A-dec 200 Chair with Support Center, Cuspidor, and Assistant s Instrumentation; Plan View (shown only with assistant s instrumentation dimensions for clarity) 8" 203 mm 45 11" 280 mm Rev B

11 A-dec 200 Dental Light; Plan View (shown only with dental light dimensions for clarity) 34" 864 mm " 597 mm Rev B 11

12 A-dec 200 Dental Light; Plan View with Elevation (shown only with dental light dimensions for clarity) 34" 864 mm " 597 mm 27" 686 mm Rev B

13 Rev B 13

14 Regulatory Information Regulatory information is provided with A-dec equipment as mandated by agency requirements. This information is delivered in the equipment s Instructions for Use or the separate Regulatory Information and Specifications document. If you need this information, please go to the Document Library at A-dec Headquarters 2601 Crestview Drive Newberg, OR USA Tel: Within USA/Canada Tel: Outside USA/Canada Fax: / A-dec Inc. makes no warranty of any kind with regard to the content in this document including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose Rev B Copyright 2012 A-dec Inc. All rights reserved.

A-dec 311 Dental Chair and Related Systems

A-dec 311 Dental Chair and Related Systems Pre-Installation Guide A-dec 311 Dental Chair and Related Systems A-dec 311 Dental Chair with 332 Radius -Style Delivery System and 572 Dental Light This document contains technical specifications for

More information

Pre-Installation Guide Performer

Pre-Installation Guide Performer Pre-Installation Guide Performer Contents Structural Requirements... 1 Dental Patient Chair Interface Requirement... 1 Utility Requirements... 1 Utility Specifications... 2 Electrical Ratings... 3 Shipping

More information

A-dec LED Dental Light Head on a Demonstration Stand INSTALLATION GUIDE

A-dec LED Dental Light Head on a Demonstration Stand INSTALLATION GUIDE A-dec LED Dental Light Head on a Demonstration Stand INSTALLATION GUIDE Introduction Use this installation guide to install an A-dec LED Dental Light Retrofit Kit (28.1924.00 or 28.1925.00) on a custom

More information

A-dec 336 Delivery System on an A-dec 411 or 511 Dental Chair INSTALLATION GUIDE

A-dec 336 Delivery System on an A-dec 411 or 511 Dental Chair INSTALLATION GUIDE A-dec 6 Delivery System on an A-dec 4 or 5 Dental Chair INSTALLATION GUIDE Before You Install the 6 Delivery System Install the Rigid Arm A-dec 4 Dental Chair: Follow the instructions for installing the

More information

Cascade 3072 Delivery System INSTALLATION GUIDE

Cascade 3072 Delivery System INSTALLATION GUIDE Cascade 3072 Delivery System INSTALLATION GUIDE Getting Started Figure 1. Cascade 3072 Delivery System See the section below that applies to your unit. the Wall............. 1 Preference II 5512 Cabinet......................................

More information

A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE

A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE Contents Before You Begin.......... 2 Install the Rigid Arm....... 3 Connect the Electrical Wires and Data

More information

A-dec 570L Dental Light on a Non-DCS System INSTALLATION GUIDE

A-dec 570L Dental Light on a Non-DCS System INSTALLATION GUIDE A-dec 570L Dental Light on a Non-DCS System INSTALLATION GUIDE Non-DCS LED Dental Light 86.0350.00 Rev B Choose an Installation Guide The manual used to install the light depends on whether the system

More information

A-dec Dental Lights on an A-dec 300 Base Mount Post INSTALLATION GUIDE

A-dec Dental Lights on an A-dec 300 Base Mount Post INSTALLATION GUIDE A-dec Dental Lights on an A-dec 300 Base Mount Post INSTALLATION GUIDE Before You Begin Turn off the power to the system before you begin the installation. DANGER Failure to turn off the power before you

More information

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide Language of origin: English Equipment Alert Do not remove wraps or packaging from the delivery flex arm assembly until it is

More information

A-dec 541 Delivery System and 545 Assistant s Instrumentation

A-dec 541 Delivery System and 545 Assistant s Instrumentation Installation Guide A-dec 541 Delivery System and 545 Assistant s Instrumentation Before You Begin A-dec 545 12 O Clock Assistant s Instrumentation The instructions are the same for installing both the

More information

A-dec O Clock Delivery System

A-dec O Clock Delivery System Installation Guide A-dec 500 12 O Clock Delivery System Before You Begin A-dec 545 12 O Clock Assistant s Instrumentation Before starting the installation: Check with local building and code authorities

More information

Instructions for Use. Cascade 2615 Cart

Instructions for Use. Cascade 2615 Cart Instructions for Use Cascade 2615 Cart 85.0664.00 Copyright 2016 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the

More information

Regulatory Information and

Regulatory Information and Regulatory Information and Introduction A-dec products. The information contained here supersedes regulatory information included in any other document that came with your A-dec product. Equipment Alterations

More information

Assistant s Instrumentation T

Assistant s Instrumentation T Instructions for Use Assistant s Instrumentation 85.2610.00 T Copyright 2015 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited

More information

Instructions for Use. A-dec 4631 Duo Delivery System and A-dec 4635 Assistant s

Instructions for Use. A-dec 4631 Duo Delivery System and A-dec 4635 Assistant s Instructions for Use A-dec 4631 Duo Delivery System and A-dec 4635 Assistant s 85.2643.00 Copyright 2016 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material,

More information

A-dec 371L or 571L Dental Light on an A-dec 361, 362, or 363 Support Center INSTALLATION GUIDE

A-dec 371L or 571L Dental Light on an A-dec 361, 362, or 363 Support Center INSTALLATION GUIDE A-dec 37L or 57L Dental Light on an A-dec 36, 36, or 363 Support Center INSTALLATION GUIDE 37L 57L Before You Begin WARNING Failure to turn off or disconnect the power before you begin this procedure can

More information

A-dec 300 LED Dental Light

A-dec 300 LED Dental Light Instructions for Use A-dec 300 LED Dental Light Models 371L 378L A-dec 300 LED Dental Light Instructions for Use Copyright 2018 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind

More information

A-dec 542 Side Delivery System I NSTALLATION GUIDE

A-dec 542 Side Delivery System I NSTALLATION GUIDE -dec 542 Side Delivery System I NSTLLTION GUIDE This document contains installation instructions for the -dec 542 side delivery system. NOTE Depending on your equipment configuration, some steps in the

More information

Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs)

Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs) INSTALLATION INSTRUCTIONS Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs) You Will Need: Hex key set Level Large flat head screwdriver Pliers 1/2" and 9/16" wrench Cutters Before Beginning

More information

A-dec 2122/2132 Radius System on A-dec 511 Dental Chair I NSTALLATION GUIDE

A-dec 2122/2132 Radius System on A-dec 511 Dental Chair I NSTALLATION GUIDE -dec 2122/2132 Radius System on -dec 511 ental hair I NSTLLTION GUIE Introduction This document contains instructions for installing an -dec Radius delivery system on an -dec Model 511 chair. This guide

More information

A-dec 300 Delivery Systems

A-dec 300 Delivery Systems Instructions for Use A-dec 300 Delivery Systems Models 332, 333, 334, 335, and 336 A-dec 300 Delivery Systems Instructions for Use Copyright 2017 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty

More information

A-dec 500 Delivery Systems

A-dec 500 Delivery Systems Instructions for Use A-dec 500 Delivery Systems Models 532, 533, and 542 A-dec 500 Delivery Systems Instructions for Use Copyright 2016 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any

More information

INSTRUCTIONS FOR USE. A-dec 311 Dental Chair

INSTRUCTIONS FOR USE. A-dec 311 Dental Chair INSTRUCTIONS FOR USE A-dec 311 Dental Chair A-DEC 311 D ENTAL CHAIR I NSTRUCTIONS FOR USE Copyright 2008 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material,

More information

Asepsis 21 Delivery Unit

Asepsis 21 Delivery Unit INSTALLATION INSTRUCTIONS for the Console Mounted TM Asepsis 21 Delivery Unit SECTION I - REQUIREMENTS 1. PHYSICAL REQUIREMENTS... 1 2. ELECTRICAL REQUIREMENTS... 1 3. WATER SUPPLY REQUIREMENTS... 1 4.

More information

Instructions for Use. A-dec EA-30. Electric Motor System

Instructions for Use. A-dec EA-30. Electric Motor System Instructions for Use A-dec EA-30 Electric Motor System Copyright 2012 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited to,

More information

A-dec 311, 411, and 511 Dental Chairs Service Reference

A-dec 311, 411, and 511 Dental Chairs Service Reference A-dec,, and Dental Chairs Service Reference Copyright Regulatory Information Contents 0 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including,

More information

The A-dec Difference.

The A-dec Difference. A-dec 200 The A-dec Difference. The best way to discover what dentists need in a chair and delivery system is to ask. We did. And the A-dec 200 design reflects the way dental teams work, and purposefully

More information

Owner s Guide PERFORMER III

Owner s Guide PERFORMER III Owner s Guide PERFORMER III 85.2638.00 R ALPHABETICAL EQUIVALENT TO THE NUMERAL OF THE MONTH MANUFACTURED A B C D E F G H I J K L January February March April May June July August September October November

More information

Owner's Guide CASCADE 2671 DUO CART AND CASCADE 3171 DUO WALL-MOUNT

Owner's Guide CASCADE 2671 DUO CART AND CASCADE 3171 DUO WALL-MOUNT Owner's Guide CASCADE 2671 DUO CART AND CASCADE 3171 DUO WALL-MOUNT 85.2641.00 ALPHABETICAL EQUIVALENT TO THE NUMERAL OF THE MONTH MANUFACTURED A B C D E F G H I J K L January February March April May

More information

DECADE 1021 SOLO CHAIR

DECADE 1021 SOLO CHAIR Owner's Guide DECADE 1021 SOLO CHAIR 85-2626-00 Warranty A-dec warrants its products against defects in material or workmanship for one year from time of delivery (except for handpieces which have a warranty

More information

Cascade Master Series

Cascade Master Series Overview The Cascade Master Series option consists of five components, which control standard chair and delivery system functions. These components include: master touchpad, master 17-watt power supply,

More information

INSTRUCTIONS FOR USE CASCADE 2615 CART AND 3175 WALL MOUNT

INSTRUCTIONS FOR USE CASCADE 2615 CART AND 3175 WALL MOUNT INSTRUCTIONS FOR USE CASCADE 2615 CART AND 3175 WALL MOUNT 85.0664.00 R Warranty ALPHABETICAL EQUIVALENT TO THE NUMERAL OF THE MONTH MANUFACTURED A B C D E F G H I J K L January February March April May

More information

INSTALLATION MANUAL. Contour & Contour LX Pedicure Chairs. Contour. Contour LX Rev B 5/11/18

INSTALLATION MANUAL. Contour & Contour LX Pedicure Chairs. Contour. Contour LX Rev B 5/11/18 INSTALLATION MANUAL Contour & Contour L Pedicure Chairs Contour Contour L *shown with optional accessories and/or finishes 1-400-0051 Rev B 5/11/18 Living Earth Crafts 2018, All Rights Reserved Legal Notice

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.

More information

A-dec Stools. A-dec 1601 Doctor's Stool A-dec 1621, 1622, and 1626 Assistant's Stools

A-dec Stools. A-dec 1601 Doctor's Stool A-dec 1621, 1622, and 1626 Assistant's Stools Instructions for Use -dec Stools -dec 1601 Doctor's Stool -dec 1621, 1622, and 1626 ssistant's Stools -DEC STOOLS I NSTRUCTIONS FOR USE Copyright 2009 -dec Inc. ll rights reserved. -dec Inc. makes no warranty

More information

CASCADE CHAIR-MOUNTED HANDPIECE CONTROL WITH CASCADE MASTER SERIES TOUCH PAD

CASCADE CHAIR-MOUNTED HANDPIECE CONTROL WITH CASCADE MASTER SERIES TOUCH PAD R A-DEC INC. 2601 CRESTVIEW DRIVE POST OFFICE BOX 111 NEWBERG, OREGON 97132 USA TELEPHONE (503)-538-9471 DESIGNATED E.U. REPRESENTATIVE: A-DEC DENTAL U.K., LTD. AUSTIN HOUSE 11 LIBERTY WAY ATTLEBOROUGH

More information

Installation Instructions: Over-The-Patient Units (& Cuspidors) BDS-2500 BDS-2505 BDS-2510 BDS-2515 BDS-2520

Installation Instructions: Over-The-Patient Units (& Cuspidors) BDS-2500 BDS-2505 BDS-2510 BDS-2515 BDS-2520 Installation Instructions: Over-The-Patient Units (& Cuspidors) BDS-2500 BDS-2505 BDS-2510 BDS-2515 BDS-2520 X-Calibur BDS Delivery Systems Installation Instructions for BDS-2500, 2505, 2510, 2515, 2520

More information

Instruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR. Hydraulic Generator. Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

Instruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR. Hydraulic Generator. Manufacturing of: Vehicle Mounted Generators Hydraulic Generators Setting the Standard in Mobile Power Instruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR Hydraulic Generator Manufacturing of: Vehicle Mounted Generators Hydraulic Generators P.O. Box 582 Chester,

More information

A-dec 200 Service Guide Contents

A-dec 200 Service Guide Contents A-dec 200 Service Guide 1 A-dec 200 Service Guide Contents Overview... 3 Get Support... 3 International Customer Service... 3 Other Sources of Information... 3 Electronic Documentation... 3 A-dec 200 System

More information

PowerMax Surgical Suction Producers

PowerMax Surgical Suction Producers PowerMax Surgical Suction Producers Models: PM-1, PM-3, PM-4 Installation & Operation 10496800 Rev. B Table of Contents Section 1 About PowerMax...1 Section 2 Specifications & Model Selection...3 2.1

More information

Instructions for Use. A-dec EA-53 Electric Motor

Instructions for Use. A-dec EA-53 Electric Motor Instructions for Use A-dec EA-53 Electric Motor A-dec EA-53 Electric Motor Instructions for Use Copyright 2014 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this

More information

SERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX

SERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX GORMAN-RUPP AT YOUR SERVICE THE GORMAN-RUPP COMPANY P.O. Box MANSFIELD, OH. 90 9..0 FX 9.. EMAIL GRSALES@GORMANRUPP.COM How To Read Pump Performance Curves The subject of this bulletin covers the reading

More information

AirStar Tandem Installation Kit Part Number 85694

AirStar Tandem Installation Kit Part Number 85694 Tandem Installation Kit Part Number 8569 Kit Parts Supplied Part No. Description Quantity 60510 10 PSI Safety Relief Valve 866 85-115 psi 1 85686 Installation Schematic for two Tandem compressors 1 System

More information

ClassicSeries Compressor Installation

ClassicSeries Compressor Installation ClassicSeries Compressor Installation Applies to Models: CL21-115 Volts CL22, CL32, CL52-208- 230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Note:

More information

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications

More information

Table of Contents Next FLO-SAFE Manifold System Pre-Installation Kit Matrx Toll-Free: Technical Support: Fax: Rev.

Table of Contents Next FLO-SAFE Manifold System Pre-Installation Kit Matrx Toll-Free: Technical Support: Fax: Rev. FLO-SAFE Manifold System Pre-Installation Kit Instruction Manual Matrx 145 Mid County Drive Orchard Park, New York 14127 716-662-6650 Toll-Free: 800-847-1000 Technical Support: 888-279-1260 Fax: 716-662-8440

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

Simplicity Magellan Unit

Simplicity Magellan Unit Simplicity Magellan Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 2 Classifications... 2-3 Dimensions... 3 Basic

More information

The Da-Lite Difference.

The Da-Lite Difference. The Da-Lite Difference. Instruction Book for Boardroom Electrol DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737 Fax:

More information

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY Issue 5 24/48 VOLT DC SWITCHING POWER SUPPLY INTRODUCTION These instructions provide the specifications, installation and maintenance information for the VP-4124 and VP-4124-E, 24/48 Volt Power Supplies.

More information

TELETOM PREINSTALLATION MANUAL

TELETOM PREINSTALLATION MANUAL TELETOM PREINSTALLATION MANUAL MANUAL ORGANIZATION SAFETY CONTENTS SECTION 1 INTRODUCTION...1-1 DESCRIPTION...1-1 PRE-INSTALLATION RESPONSIBILITIES...1-2 BERCHTOLD RESPONSIBILITIES...1-2 OWNER RESPONSIBILITIES...1-3

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS Part Numbers: 54580 and 54580-2 Part Number 54580 Shown OUT IN INSTALLATION and OPERATION INSTRUCTIONS TABLE OF CONTENTS Section Page Warranty.... 2 General Information.... 3 Introduction..... 3 System

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

INSTALLATION INSTRUCTIONS CASCADE 3181 DUO DELIVERY SYSTEM TO PREFERENCECOLLECTION 5580

INSTALLATION INSTRUCTIONS CASCADE 3181 DUO DELIVERY SYSTEM TO PREFERENCECOLLECTION 5580 R A-DEC INC. 2601 CRESTVIEW DRIVE POST OFFICE BOX 111 NEWBERG, OREGON 97132 USA TELEPHONE (503)-538-9471 DESIGNATED E.U. REPRESENTATIVE: A-DEC DENTAL U.K., LTD. AUSTIN HOUSE 11 LIBERTY WAY ATTLEBOROUGH

More information

Multi-Tank Submersible Pump Install Manual

Multi-Tank Submersible Pump Install Manual Multi-Tank Submersible Pump Install Manual Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 03/01/2011

More information

ELECTRICAL POWER GUIDE INTERNATIONAL EDITION

ELECTRICAL POWER GUIDE INTERNATIONAL EDITION ELECTRICAL POWER GUIDE INTERNATIONAL EDITION INNOVATION Gas-Fired Hot Water Boilers Natural Gas Modulating, Condensing Hot Water Boiler Models: INN800 INN1060 INN1350 Technical Support: (Mon Fri, 8am-5pm

More information

AVL SERIES. Technical Specifications. Compressed Air Loaders. Features

AVL SERIES. Technical Specifications. Compressed Air Loaders. Features Material Handling Process Cooling Temperature Control Size Reduction Compressed Air Loaders Technical Specifications Features (Shown with Optional Sight Glass) AVL loaders are designed to provide trouble-free

More information

Installation Operation Maintenance Troubleshooting Version 1, Oct/09. Palm Beach

Installation Operation Maintenance Troubleshooting Version 1, Oct/09. Palm Beach Installation Operation Maintenance Troubleshooting Version 1, Oct/09 1655 Palm Beach Congratulations! All of us at Summit Dental Systems want you to know that your 1655 Palm Beach Cuspidor has been built

More information

Section 02: Pre-Installation Procedures

Section 02: Pre-Installation Procedures Section 02: Pre-Installation Procedures Foundation! WARNING The MUST be placed on a surface that will support the combined weight of the, options, fixtures, and tooling, etc. (refer to the Specifications

More information

model 2000SN FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS Recessed Wall-Mount Bottle Filling Station

model 2000SN FEATURES & BENEFITS SPECIFICATIONS OPTIONS APPLICATIONS Recessed Wall-Mount Bottle Filling Station model 2000SN Recessed Wall-Mount Bottle Filling Station FEATURES & BENEFITS QUALITY CONTROL The Haws bottle filling station is pre-built and fully water and pressure tested to ensure no leaks and proper

More information

Owners Installation, Operation, and Safety Manual

Owners Installation, Operation, and Safety Manual Owners Installation, Operation, and Safety Manual Remote Dispensing Cabinets Models FR102PH FR302DP FR902DP FR910PM Tuthill Corporation 8825 Aviation Drive Ft. Wayne, IN 46809 (260) 747-7529 www.tuthill.com

More information

Instructions for Use. Performer. Dental Chair, Delivery System, Assistant s Instrumentation, Support Center with Cuspidor, and Light

Instructions for Use. Performer. Dental Chair, Delivery System, Assistant s Instrumentation, Support Center with Cuspidor, and Light Instructions for Use Performer Dental Chair, Delivery System, Assistant s Instrumentation, Support Center with Cuspidor, and Light Performer Instructions for Use Copyright 2017 A-dec Inc. All rights reserved.

More information

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Safety, Installation and Service Manual Models 1952, 1953 & 1972 Ultraviolet Germicidal Lamps Model 1952 24 Rooftop Unit Model 1953 32 Rooftop Unit Model 1972 Rooftop Unit, Internal Mount Safety, Installation and Service Manual Models 1952, 1953 & 1972 READ AND SAVE

More information

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan MULTIPLEX 2100 FUTURE, SELLERSBURG, IN 47172 800-367-4233 WWW.MANITOWOCBEVERAGE.COM/US Instruction Sheet Subject: Installations Instructions Importan Read the following warnings before beginning an installation.

More information

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Notice to Installer: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding

More information

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY INSTRUCTION MANUAL AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM MODEL #: #:091-9B-1 091-9B-1 INPUT :120 volt, 50/60 Hz, 1.8 AMPS OUTPUT: 100 PSI MAXIMUM File: 091-9B-1_revA1_GEN3 Rev: A1 Revised By:PSS/JRN

More information

PowerAir Compressor Installation

PowerAir Compressor Installation PowerAir Compressor Installation Applies to Models: P21-115 Volts P22, P32-230 Volts P52, P72-230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Model

More information

X-Calibur BDS Delivery Systems

X-Calibur BDS Delivery Systems X-Calibur BDS Delivery Systems Table of Contents Page Customer Unit Identification Record 1 General Unit Anatomy 2 Types Of Units 3 Description of Components 5 Control Head Features 5 Cuspidor Features

More information

D05 Directional Control Valves

D05 Directional Control Valves Engineering D05 Directional Control Valves WFDG4S*4-01, 60 Design Wet Armature Solenoid Operated Max Pressure up to 248 Bar (3600 psi) Same Day Shipments www.fluidynefp.com Table of Contents Basic Characteristicts...2

More information

HLC CEILING MOUNTED DENTAL LIGHT. INSTALLATION and OPERATING INSTRUCTIONS. Rev.3

HLC CEILING MOUNTED DENTAL LIGHT. INSTALLATION and OPERATING INSTRUCTIONS. Rev.3 HLC CEILING MOUNTED DENTAL LIGHT INSTALLATION and OPERATING INSTRUCTIONS Rev.3 PRE-INSTALLATION REQUIREMENTS: HLC CEILING MOUNTED LIGHT To insure a safe and proper installation of HLC ceiling mounted light,

More information

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream Dry Vacuum System Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL Recommend Daily use of Monarch CleanStream TABLE OF CONTENTS Description Page Congratulations...3 Purpose of this Manual....3 Safety

More information

QUALITY MISTING PUMPS

QUALITY MISTING PUMPS DIRECT DRIVE TOTALLY ENCLOSED FAN COOLED 60200KH, 60201KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION, PARTS, MAINTENANCE & WARRANTY QUALITY MISTING

More information

Service Guide A-DEC SIMULATORS. Mobile (4810) and Stationary (4820)

Service Guide A-DEC SIMULATORS. Mobile (4810) and Stationary (4820) Service Guide A-DEC SIMULATORS Mobile (4810) and Stationary (4820) A-DEC M OBILE AND STATIONARY SIMULATORS 4810 AND 4820 S ERVICE GUIDE Copyright 2015 A-dec Inc. All rights reserved. 2601 Crestview Drive,

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

RETRACTABLE CEILING COLUMN

RETRACTABLE CEILING COLUMN RETRACTABLE CEILING COLUMN Installation Manual RETRACTABLE CEILING COLUMN INTRODUCTION Location, sequence of services and orientation of Surgical Ceiling Columns are specified on the building plans. Be

More information

Performance Stools. Seating That s Made to Perform

Performance Stools. Seating That s Made to Perform Performance Stools Seating That s Made to Perform A-dec 500 Performance Stools. Ultimate Comfort for the Dental Team You provide the best care for your patients when you re able to work comfortably. Now,

More information

DECADE 1021 VAC BACK CHAIR

DECADE 1021 VAC BACK CHAIR Owner's Guide DECADE 1021 VAC BACK CHAIR 85-2625-00 Warranty A-dec warrants its products against defects in material or workmanship for one year from time of delivery (except for handpieces which have

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Addendum. Remote Air-Cooled Condenser

Addendum. Remote Air-Cooled Condenser Addendum Remote Air-Cooled Condenser Contents Overview... 1 Save these instructions........................... 1 Safety symbols that may be used in this manual........... 1 Cross-reference symbols used

More information

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS Page 350.1 Series Description Viking s HG series positive displacement pumps are designed to provide low noise transfer and processing of clean, lubricating liquids for applications such as lube oils,

More information

Spirit 2000 Series Installation Instructions

Spirit 2000 Series Installation Instructions Model: SCT20 Catalog: 2100, 2105 PMU Mounted Catalog 2222, 2322 Cabinet Mounted Model: SDW-D Catalog: 2600 Wall Mounted Model: SDC-D Catalog: 2610 Cabinet Mounted Spirit 2000 Series Installation Instructions

More information

Product Name Chair Conversion Kit (to LR Delivery Unit) Installation [Kit # xx]

Product Name Chair Conversion Kit (to LR Delivery Unit) Installation [Kit # xx] Elevance Product Name Chair Conversion Kit (to LR Delivery Unit) Installation Installation [Kit #002-1966-xx] Attention: Use this kit to convert an Elevance Chair to a Chair with an Elevance LR mounted

More information

Simplicity Chair Mounted Unit

Simplicity Chair Mounted Unit Simplicity Chair Mounted Unit Installation, Operation & Care Manual DentalEZ MAKES YOUR PRACTICE PERFECT Table of Contents Section I Introduction Specifications... 3 Classifications... 3 Dimensions...

More information

ILCS EDGE System Installation Manual

ILCS EDGE System Installation Manual ILCS EDGE System Installation Manual 0900885 Rev: A (12/06) Page 1 of 12 TABLE OF CONTENTS System Overview... 3 System Components... 3 System Diagram... 4 Pre-Installation... 5 Control Box & Power Supply

More information

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131 Notice to Installer: Instructions must remain with installation. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.

More information

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY BOOK# 091-9B-220 4-18-2002 INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC AIR COMPRESSOR SYSTEM MODEL #091-9B-220 INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY KUSSMAUL

More information

3 HP 7 1/2 HP 9 5 HP. RAIL/TRUCK PROBE 5 HP

3 HP 7 1/2 HP 9 5 HP. RAIL/TRUCK PROBE 5 HP 9 ft. on 5 HP. 3 HP 5 HP 7 1/2 HP RAIL/TRUCK PROBE A B C D E F G H I J 3HP (feet-inches) 7'0" 4'0" 6'11" 11'6" 15'2" 24'2" 11'8" 2'4" 0.0 0.0 3HP (meters) 2.13 1.22 2.11 3.51 4.62 7.37 3.57 0.7 0.0 0.0

More information

Legendary A-dec reliability

Legendary A-dec reliability A-dec 500 Legendary A-dec reliability You can count on A-dec equipment to work when you do. Innovative engineering Legendary A-dec reliability starts with our design philosophy create innovative, feature-rich

More information

The A-dec Difference Built for Life

The A-dec Difference Built for Life A-dec 300 The A-dec Difference Built for Life At A-dec, no detail is too small, right down to the bolts that go into our products. That s why we manufacture a large majority of our finished dental equipment

More information

1 AMP CURRENT SOURCE

1 AMP CURRENT SOURCE 1 AMP CURRENT SOURCE CS-2000-U CS-2000-E USER MANUAL BC BIOMEDICAL CS-2000 SERIES TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES... ii DESCRIPTION... 1 LAYOUT... 2 OPERATION... 4 TESTING... 6 MANUAL REVISIONS...

More information

Dental Vacuum System. Installation Overview

Dental Vacuum System. Installation Overview Dental Vacuum System Installation Overview This guide contains site preparation and installation instructions for RAMVAC Bulldog QT and Bison Dental Vacuum Systems with S1 Electrols. It is recommended

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings

In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings In-Duct High Pressure Nozzle Humidification System - HP HVAC Series Submittal Drawings Date: Job Name: Contractor: Contractor or Order No.: Engineer: Agent: Agent P.O. No.: Date Ordered: Date Required:

More information

The A-dec Difference Built for Life

The A-dec Difference Built for Life A-dec 300 The A-dec Difference Built for Life At A-dec, no detail is too small, right down to the bolts that go into our products. That s why we manufacture a large majority of our finished dental equipment

More information

Transient Fault Location for Branch Circuit Breakers TFT Turquoise Circle Newbury Park, CA Toll Free:

Transient Fault Location for Branch Circuit Breakers TFT Turquoise Circle Newbury Park, CA Toll Free: TFT100 2450 Turquoise Circle Newbury Park, CA 91320 Toll Free: 800-749-5783 User Manual Introduction Fault Trapper is a new class of tester intended to locate the distance to a circuit anomaly that is

More information

The Da-Lite Difference.

The Da-Lite Difference. The Da-Lite Difference. Instruction Book for Cosmopolitan Electrol For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC. 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101

More information

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION MANUAL. Melink Corporation (513) Revision INSTALLATION MANUAL Revision 130711 Table of Contents Step Installation Contractor Page 1 Install System Controller Electrical 4 2 Install Variable Frequency Drive Electrical 6 3 Install Touchpad Mechanical

More information

PROPER ELECTRICAL CONNECTIONS

PROPER ELECTRICAL CONNECTIONS INSTALLATION 230 Volt 13 ampere 50 Hz The SUITMATE Swimsuit Water Extractor has been designed and manufactured with safety as our primary consideration. Therefore, it is important that the unit be installed

More information

Preinstallation Worksheet 3M Detection Systems Please complete this form and fax it to 3M at

Preinstallation Worksheet 3M Detection Systems Please complete this form and fax it to 3M at Preinstallation Worksheet 3M Detection Systems Please complete this form and fax it to 3M at 1-800-795-9091. Today s date Sales consultant Account name Key contact name Phone No. Installation location

More information